Sample records for probability bracket notation

  1. ProForma: A Standard Proteoform Notation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeDuc, Richard D.; Schwämmle, Veit; Shortreed, Michael R.

    The Consortium for Top-Down Proteomics (CTDP) proposes a standardized notation, ProForma, for writing the sequence of fully characterized proteoforms. ProForma provides a means to communicate any proteoform by writing the amino acid sequence using standard one-letter notation and specifying modifications or unidentified mass shifts within brackets following certain amino acids. The notation is unambiguous, human readable, and can easily be parsed and written by bioinformatic tools. This system uses seven rules and supports a wide range of possible use cases, ensuring compatibility and reproducibility of proteoform annotations. Standardizing proteoform sequences will simplify storage, comparison, and reanalysis of proteomic studies, andmore » the Consortium welcomes input and contributions from the research community on the continued design and maintenance of this standard.« less

  2. New algorithms to represent complex pseudoknotted RNA structures in dot-bracket notation.

    PubMed

    Antczak, Maciej; Popenda, Mariusz; Zok, Tomasz; Zurkowski, Michal; Adamiak, Ryszard W; Szachniuk, Marta

    2018-04-15

    Understanding the formation, architecture and roles of pseudoknots in RNA structures are one of the most difficult challenges in RNA computational biology and structural bioinformatics. Methods predicting pseudoknots typically perform this with poor accuracy, often despite experimental data incorporation. Existing bioinformatic approaches differ in terms of pseudoknots' recognition and revealing their nature. A few ways of pseudoknot classification exist, most common ones refer to a genus or order. Following the latter one, we propose new algorithms that identify pseudoknots in RNA structure provided in BPSEQ format, determine their order and encode in dot-bracket-letter notation. The proposed encoding aims to illustrate the hierarchy of RNA folding. New algorithms are based on dynamic programming and hybrid (combining exhaustive search and random walk) approaches. They evolved from elementary algorithm implemented within the workflow of RNA FRABASE 1.0, our database of RNA structure fragments. They use different scoring functions to rank dissimilar dot-bracket representations of RNA structure. Computational experiments show an advantage of new methods over the others, especially for large RNA structures. Presented algorithms have been implemented as new functionality of RNApdbee webserver and are ready to use at http://rnapdbee.cs.put.poznan.pl. mszachniuk@cs.put.poznan.pl. Supplementary data are available at Bioinformatics online.

  3. Lambda: A Mathematica package for operator product expansions in vertex algebras

    NASA Astrophysics Data System (ADS)

    Ekstrand, Joel

    2011-02-01

    We give an introduction to the Mathematica package Lambda, designed for calculating λ-brackets in both vertex algebras, and in SUSY vertex algebras. This is equivalent to calculating operator product expansions in two-dimensional conformal field theory. The syntax of λ-brackets is reviewed, and some simple examples are shown, both in component notation, and in N=1 superfield notation. Program summaryProgram title: Lambda Catalogue identifier: AEHF_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEHF_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License No. of lines in distributed program, including test data, etc.: 18 087 No. of bytes in distributed program, including test data, etc.: 131 812 Distribution format: tar.gz Programming language: Mathematica Computer: See specifications for running Mathematica V7 or above. Operating system: See specifications for running Mathematica V7 or above. RAM: Varies greatly depending on calculation to be performed. Classification: 4.2, 5, 11.1. Nature of problem: Calculate operator product expansions (OPEs) of composite fields in 2d conformal field theory. Solution method: Implementation of the algebraic formulation of OPEs given by vertex algebras, and especially by λ-brackets. Running time: Varies greatly depending on calculation requested. The example notebook provided takes about 3 s to run.

  4. A Converse of a Result about the Floor Function by Hermite

    ERIC Educational Resources Information Center

    Mortici, Cristinel

    2012-01-01

    The floor function maps a real number to the largest previous integer. More precisely, floor(x)=[x] is the largest integer not greater than x. The square bracket notation [x] for the floor function was introduced by Gauss in his third proof of quadratic reciprocity in 1808. The floor function is also called the greatest integer or entier (French…

  5. A Knowledge-Based Approach to Language Production

    DTIC Science & Technology

    1985-08-01

    representation -- the internal structures which the system is generating from. and (3) the choice problem -- how the intricate relationship between the...texts from several different internal representations. One example of the output produced by MUMBLE is the following text, produced from a...brackets. This notation is used to illustrate some templates which are encoded in Ace. The internal representation of these templates is achieved using

  6. Structural Features of Algebraic Quantum Notations

    ERIC Educational Resources Information Center

    Gire, Elizabeth; Price, Edward

    2015-01-01

    The formalism of quantum mechanics includes a rich collection of representations for describing quantum systems, including functions, graphs, matrices, histograms of probabilities, and Dirac notation. The varied features of these representations affect how computations are performed. For example, identifying probabilities of measurement outcomes…

  7. Formal Compiler Implementation in a Logical Framework

    DTIC Science & Technology

    2003-04-29

    variable set [], we omit the brackets and use the simpler notation v. MetaPRL is a tactic-based prover that uses OCaml [20] as its meta-language. When a...rewrite is defined in MetaPRL, the framework creates an OCaml expression that can be used to apply the rewrite. Code to guide the application of...rewrites is written in OCaml , using a rich set of primitives provided by MetaPRL. MetaPRL automates the construction of most guidance code; we describe

  8. Conditional Independence in Applied Probability.

    ERIC Educational Resources Information Center

    Pfeiffer, Paul E.

    This material assumes the user has the background provided by a good undergraduate course in applied probability. It is felt that introductory courses in calculus, linear algebra, and perhaps some differential equations should provide the requisite experience and proficiency with mathematical concepts, notation, and argument. The document is…

  9. The Overestimation Phenomenon in a Skill-Based Gaming Context: The Case of March Madness Pools.

    PubMed

    Kwak, Dae Hee

    2016-03-01

    Over 100 million people are estimated to take part in the NCAA Men's Basketball Tournament Championship bracket contests. However, relatively little is known about consumer behavior in skill-based gaming situations (e.g., sports betting). In two studies, we investigated the overestimation phenomenon in the "March Madness" context. In Study 1 (N = 81), we found that individuals who were allowed to make their own predictions were significantly more optimistic about their performance than individuals who did not make their own selections. In Study 2 (N = 197), all subjects participated in a mock competitive bracket pool. In line with the illusion of control theory, results showed that higher self-ratings of probability of winning significantly increased maximum willingness to wager but did not improve actual performance. Lastly, perceptions of high probability of winning significantly contributed to consumers' enjoyment and willingness to participate in a bracket pool in the future.

  10. Comparative study of torque expression among active and passive self-ligating and conventional brackets

    PubMed Central

    Franco, Érika Mendonça Fernandes; Valarelli, Fabrício Pinelli; Fernandes, João Batista; Cançado, Rodrigo Hermont; de Freitas, Karina Maria Salvatore

    2015-01-01

    Abstract Objective: The aim of this study was to compare torque expression in active and passive self-ligating and conventional brackets. Methods: A total of 300 segments of stainless steel wire 0.019 x 0.025-in and six different brands of brackets (Damon 3MX, Portia, In-Ovation R, Bioquick, Roth SLI and Roth Max) were used. Torque moments were measured at 12°, 24°, 36° and 48°, using a wire torsion device associated with a universal testing machine. The data obtained were compared by analysis of variance followed by Tukey test for multiple comparisons. Regression analysis was performed by the least-squares method to generate the mathematical equation of the optimal curve for each brand of bracket. Results: Statistically significant differences were observed in the expression of torque among all evaluated bracket brands in all evaluated torsions (p < 0.05). It was found that Bioquick presented the lowest torque expression in all tested torsions; in contrast, Damon 3MX bracket presented the highest torque expression up to 36° torsion. Conclusions: The connection system between wire/bracket (active, passive self-ligating or conventional with elastic ligature) seems not to interfere in the final torque expression, the latter being probably dependent on the interaction between the wire and the bracket chosen for orthodontic mechanics. PMID:26691972

  11. Effects of self-ligating and conventional brackets on halitosis and periodontal conditions.

    PubMed

    Kaygisiz, Emine; Uzuner, Fatma Deniz; Yuksel, Sema; Taner, Levent; Çulhaoğlu, Rana; Sezgin, Yasemin; Ateş, Can

    2015-05-01

    To evaluate the effects of fixed orthodontic treatment with steel-ligated conventional brackets and self-ligating brackets on halitosis and periodontal health. Sixty patients, at the permanent dentition stage aged 12 to 18 years, who had Angle Class I malocclusion with mild-to-moderate crowding were randomly selected. Inclusion criteria were nonsmokers, without systematic disease, and no use of antibiotics and oral mouth rinses during the 2-month period before the study. The patients were subdivided into three groups randomly: the group treated with conventional brackets (group 1, n  =  20) ligated with steel ligature wires, the group treated with self-ligating brackets (group 2, n  =  20), and the control group (group 3, n  =  20). The periodontal records were obtained 1 week before bonding (T1), immediately before bonding (T2), 1 week after bonding (T3), 4 weeks after bonding (T4), and 8 weeks after bonding (T5). Measurements of the control group were repeated within the same periods. The volatile sulfur components determining halitosis were measured with the Halimeter at T2, T3, T4, and T5. A two-way repeated measures of analysis of variance (ANOVA) was used to compare the groups statistically. No statistically significant group × time interactions were found for plaque index, gingival index, pocket depth, bleeding on probing, and halitosis, which means three independent groups change like each other by time. The risk of tongue coating index (TCI) being 2 was 10.2 times higher at T1 than at T5 (P < .001). Therefore, the probability of higher TCI was decreased by time in all groups. The self-ligating brackets do not have an advantage over conventional brackets with respect to periodontal status and halitosis.

  12. Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets.

    PubMed

    Alavi, Shiva; Tajmirriahi, Farnaz

    2016-09-01

    the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT) brackets manufactured by two different companies (American Orthodontics and Ortho Organizers) and determine variations in incorporation of values in relation to tip and torque in these products. In the present analytical/descriptive study, 64 maxillary right central brackets manufactured by two companies (American Orthodontics and Ortho Organizers) were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. They were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. Then, the software program of the same machine was used to determine the values of each bracket type. The means of measurements were determined for each sample and were analyzed with independent t -test and one-sample t -test. Based on the confidence interval, it can be concluded that at 95% probability, the means of tip angles of maxillary right central brackets of these two brands were 4.1-4.3° and the torque angles were 16.39-16.72°. The tips in these samples were at a range of 3.33-4.98°, and the torque was at a range of 15.22-18.48°. In the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tiP values for the MBT prescription. In relation to torque, there was a significant difference between the American Orthodontic brackets exhibited significant differences with the reported 17°, too.

  13. Challenging assumptions of notational transparency: the case of vectors in engineering mathematics

    NASA Astrophysics Data System (ADS)

    Craig, Tracy S.

    2017-11-01

    The notation for vector analysis has a contentious nineteenth century history, with many different notations describing the same or similar concepts competing for use. While the twentieth century has seen a great deal of unification in vector analysis notation, variation still remains. In this paper, the two primary notations used for expressing the components of a vector are discussed in historical and current context. Popular mathematical texts use the two notations as if they are transparent and interchangeable. In this research project, engineering students' proficiency at vector analysis was assessed and the data were analyzed using the Rasch measurement method. Results indicate that the students found items expressed in unit vector notation more difficult than those expressed in parenthesis notation. The expert experience of notation as transparent and unproblematically symbolic of underlying processes independent of notation is shown to contrast with the student experience where the less familiar notation is experienced as harder to work with.

  14. Addendum to "Compact Perturbative Expressions for Neutrino Oscillations in Matter"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denton, Peter B.; Minakata, Hisakazu; Parke, Stephen J.

    2018-01-19

    In this paper we rewrite the neutrino mixing angles and mass squared differences in matter given, in our original paper, in a notation that is more conventional for the reader. Replacing the usual neutrino mixing angles and mass squared differences in the expressions for the vacuum oscillation probabilities with these matter mixing angles and mass squared differences gives an excellent approximation to the oscillation probabilities in matter. Comparisons for T2K, NOvA, T2HKK and DUNE are also given for neutrinos and anti-neutrinos, disappearance and appearance channels, normal ordering and inverted ordering.

  15. Representing object oriented specifications and designs with extended data flow notations

    NASA Technical Reports Server (NTRS)

    Buser, Jon Franklin; Ward, Paul T.

    1988-01-01

    The issue of using extended data flow notations to document object oriented designs and specifications is discussed. Extended data flow notations, for the purposes here, refer to notations that are based on the rules of Yourdon/DeMarco data flow analysis. The extensions include additional notation for representing real-time systems as well as some proposed extensions specific to object oriented development. Some advantages of data flow notations are stated. How data flow diagrams are used to represent software objects are investigated. Some problem areas with regard to using data flow notations for object oriented development are noted. Some initial solutions to these problems are proposed.

  16. RNAfbinv: an interactive Java application for fragment-based design of RNA sequences.

    PubMed

    Weinbrand, Lina; Avihoo, Assaf; Barash, Danny

    2013-11-15

    In RNA design problems, it is plausible to assume that the user would be interested in preserving a particular RNA secondary structure motif, or fragment, for biological reasons. The preservation could be in structure or sequence, or both. Thus, the inverse RNA folding problem could benefit from considering fragment constraints. We have developed a new interactive Java application called RNA fragment-based inverse that allows users to insert an RNA secondary structure in dot-bracket notation. It then performs sequence design that conforms to the shape of the input secondary structure, the specified thermodynamic stability, the specified mutational robustness and the user-selected fragment after shape decomposition. In this shape-based design approach, specific RNA structural motifs with known biological functions are strictly enforced, while others can possess more flexibility in their structure in favor of preserving physical attributes and additional constraints. RNAfbinv is freely available for download on the web at http://www.cs.bgu.ac.il/~RNAexinv/RNAfbinv. The site contains a help file with an explanation regarding the exact use.

  17. Alternatives to Traditional Notation.

    ERIC Educational Resources Information Center

    Gaare, Mark

    1997-01-01

    Provides a introduction and overview to alternative music notation systems. Describes guitar tablature, accordion tablature, klavarskribo (a keyboard notational system developed by Cornelius Pot, a Dutch engineer), and the digital piano roll. Briefly discusses the history of notation reform and current efforts. Includes examples from scores. (MJP)

  18. A stainless steel bracket for orthodontic application.

    PubMed

    Oh, Keun-Taek; Choo, Sung-Uk; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2005-06-01

    Aesthetics has become an essential element when choosing orthodontic fixed appliances. Most metallic brackets used in orthodontic therapy are made from stainless steel (SS) with the appropriate physical properties and good corrosion resistance, and are available as types 304, 316 and 17-4 PH SS. However, localized corrosion of these materials can frequently occur in the oral environment. This study was undertaken to evaluate the accuracy of sizing, microstructure, hardness, corrosion resistance, frictional resistance and cytotoxicity of commercially available Mini-diamond (S17400), Archist (S30403) and experimentally manufactured SR-50A (S32050) brackets. The size accuracy of Mini-diamond was the highest at all locations except for the external horizontal width of the tie wing (P < 0.05). Micrographs of the Mini-diamond and Archist showed precipitates in the grains and around their boundaries. SR-50A showed the only austenitic phase and the highest polarization resistance of the tested samples. SR-50A also had the highest corrosion resistance [SR-50A, Mini-diamond and Archist were 0.9 x 10(-3), 3.7 x 10(-3), and 7.4 x 10(-3) mm per year (mpy), respectively], in the artificial saliva. The frictional force of SR-50A decreased over time, but that of Mini-diamond and Archist increased. Therefore, SR-50A is believed to have better frictional properties to orthodontic wire than Mini-diamond and Archist. Cytotoxic results showed that the response index of SR-50A was 0/1 (mild), Mini-diamond 1/1 (mild+), and Archist 1/2 (mild+). SR-50A showed greater biocompatibility than either Mini-diamond or Archist. It is concluded that the SR-50A bracket has good frictional property, corrosion resistance and biocompatibility with a lower probability of allergic reaction, compared with conventionally used SS brackets.

  19. The Mental Representation of Music Notation: Notational Audiation

    ERIC Educational Resources Information Center

    Brodsky, Warren; Kessler, Yoav; Rubinstein, Bat-Sheva; Ginsborg, Jane; Henik, Avishai

    2008-01-01

    This study investigated the mental representation of music notation. Notational audiation is the ability to internally "hear" the music one is reading before physically hearing it performed on an instrument. In earlier studies, the authors claimed that this process engages music imagery contingent on subvocal silent singing. This study refines the…

  20. 75 FR 22148 - Request for the Technical Review of 22 Draft Skin Notation Assignments and Skin Notation Profiles

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-27

    ... notation is used for substances identified as causing or contributing to allergic contact dermatitis (ACD... CONTACT: G. Scott Dotson, NIOSH, Robert A Taft Laboratories, MS-C32, 4676 Columbia Parkway, Cincinnati, OH... chemical contact with the skin. This strategy involves the assignment of multiple skin notations for...

  1. Statistical Analysis of the Association Between Subject Headings and Their Corresponding Class Notations in Science and Technology Monographs.

    ERIC Educational Resources Information Center

    Khosh-khui, Abolghasem

    This study investigates the degree of relationship between scientific and technical subject headings and their corresponding class notations in the Dewey Decimal (DDC) and Library of Congress Classification (LCC) systems. The degree of association between a subject heading and its corresponding class of notation or notations is measured by…

  2. Pedagogy of Notation: Learning Styles Using a Constructivist, Second-Language Acquisition Approach to Dance Notation Pedagogy

    ERIC Educational Resources Information Center

    Heiland, Teresa L.

    2015-01-01

    Four undergraduate dance majors learned Motif Notation and Labanotation using a second-language acquisition, playful, constructivist approach to learning notation literacy in order to learn and dance the "Parsons Etude." Qualitative outcomes were gathered from student journals and pre- and post-tests that assessed for levels of improved…

  3. Sound Foundations: Organic Approaches to Learning Notation in Beginning Band

    ERIC Educational Resources Information Center

    West, Chad

    2016-01-01

    By starting with a foundation of sound before sight, we can help our students learn notation organically in a way that honors the natural process. This article describes five organic approaches to learning notation in beginning band: (1) iconic notation, (2) point and play, (3) student lead-sheet, (4) modeling, and (5) kid dictation. While…

  4. Effect of Color-Coded Notation on Music Achievement of Elementary Instrumental Students.

    ERIC Educational Resources Information Center

    Rogers, George L.

    1991-01-01

    Presents results of a study of color-coded notation to teach music reading to instrumental students. Finds no clear evidence that color-coded notation enhances achievement on performing by memory, sight-reading, or note naming. Suggests that some students depended on the color-coding and were unable to read uncolored notation well. (DK)

  5. Feasibility of Producing Synchronized Video Tapes as Instructional Aids in the Study of Music; Final Report.

    ERIC Educational Resources Information Center

    Skapski, George J.

    As an innovative aid to the study of music, recordings were made of musical performances and later synchronized with musical notations. To make the structures of the music more readily visible, and after experimenting with the use of staff notation, the author-developed "Nota-Graph" notation system was used. In this notation, there are…

  6. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

    PubMed Central

    Lee, Souk Min

    2015-01-01

    Objective This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Methods Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a -7° torque. The orthodontic wires used included 0.018 round and 0.019 × 0.025 in rectangular stainless steel wires. The FR was measured at 0°, 5°, and 10° angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. Results The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p < 0.001). The metal passive self-ligating brackets exhibited the lowest static FR at the 0° angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. Conclusions The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation. PMID:25667913

  7. [Polar and non polar notations of refraction].

    PubMed

    Touzeau, O; Gaujoux, T; Costantini, E; Borderie, V; Laroche, L

    2010-01-01

    Refraction can be expressed by four polar notations which correspond to four different combinations of spherical or cylindrical lenses. Conventional expressions of refraction (plus and minus cylinder notation) are described by sphere, cylinder, and axis. In the plus cylinder notation, the axis visualizes the most powerful meridian. The axis usually corresponds to the bow tie axis in curvature maps. Plus cylinder notation is also valuable for all relaxing procedures (i.e., selective suture ablation, arcuate keratotomy, etc.). In the cross-cylinder notation, two orthogonal cylinders can describe (without the sphere component) the actual refraction of both the principal meridians. This notation must be made before performing the vertex calculation. Using an association of a Jackson cross-cylinder and a spherical equivalent, refraction can be broken down into two pure components: astigmatism and sphere. All polar notations of refraction may perfectly characterize a single refraction but are not suitable for statistical analysis, which requires nonpolar expression. After doubling the axis, a rectangular projection breaks down the Jackson cross-cylinder, which has a polar axis, into two Jackson cross-cylinders on the 0 degrees /90 degrees and 45 degrees /135 degrees axis. This procedure results in the loss of the directional nature of the data. Refraction can be written in a nonpolar notation by three rectangular coordinates (x,y,z), which can also represent the spherocylinder by one point in a dioptric space. These three independent (orthogonal) variables have a concrete optical significance: a spherical component, a direct/inverse (WTR/ATR) component, and an oblique component of the astigmatism. Finally, nonpolar notations are useful for statistical analysis and graphical representation of refraction. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.

  8. Children's understanding of fraction and decimal symbols and the notation-specific relation to pre-algebra ability.

    PubMed

    Hurst, Michelle A; Cordes, Sara

    2018-04-01

    Fraction and decimal concepts are notoriously difficult for children to learn yet are a major component of elementary and middle school math curriculum and an important prerequisite for higher order mathematics (i.e., algebra). Thus, recently there has been a push to understand how children think about rational number magnitudes in order to understand how to promote rational number understanding. However, prior work investigating these questions has focused almost exclusively on fraction notation, overlooking the open questions of how children integrate rational number magnitudes presented in distinct notations (i.e., fractions, decimals, and whole numbers) and whether understanding of these distinct notations may independently contribute to pre-algebra ability. In the current study, we investigated rational number magnitude and arithmetic performance in both fraction and decimal notation in fourth- to seventh-grade children. We then explored how these measures of rational number ability predicted pre-algebra ability. Results reveal that children do represent the magnitudes of fractions and decimals as falling within a single numerical continuum and that, despite greater experience with fraction notation, children are more accurate when processing decimal notation than when processing fraction notation. Regression analyses revealed that both magnitude and arithmetic performance predicted pre-algebra ability, but magnitude understanding may be particularly unique and depend on notation. The educational implications of differences between children in the current study and previous work with adults are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Investigation into the effects of stainless steel ligature ties on the mechanical characteristics of conventional and self-ligated brackets subjected to torque.

    PubMed

    Al Fakir, Hussam; Carey, Jason P; Melenka, Garrett W; Nobes, David S; Heo, Giseon; Major, Paul W

    2014-09-01

    Torque is applied to orthodontic brackets in order to alter the buccal-lingual angulation of a tooth. One factor that can affect torque is the ligation mode used to retain the archwire in the bracket slot. The objective of this study was to investigate the effects of stainless steel ligation on torque expression and bracket deformation. This study utilized 60 upper right central incisor Damon Q brackets and 60 Ormco Orthos Twin brackets. The brackets used in this study were subdivided into four groups: (1) Damon Q ligated with SS ligature; (2) Damon Q with the sliding bracket door; (3) Orthos Twin bracket ligated with SS wire; and (4) Orthos Twin ligated with elastic ties. All brackets were tested using an orthodontic torque simulating device that applied archwire rotation from 0° to 45°. All brackets ligated with stainless steel ties exhibited greater torque expression and less deformation than brackets without stainless steel ties. As well, Damon Q brackets exhibit less bracket deformation than Orthos Twin brackets. Stainless steel ties can reduce the amount of plastic deformation for both types of brackets used in this study. © 2014 British Orthodontic Society.

  10. Evaluation of mechanical properties of esthetic brackets.

    PubMed

    Matsui, Shigeyuki; Umezaki, Eisaku; Komazawa, Daigo; Otsuka, Yuichiro; Suda, Naoto

    2015-01-01

    Plastic brackets, as well as ceramic brackets, are used in various cases since they have excellent esthetics. However, their mechanical properties remain uncertain. The purpose of this study was to determine how deformation and stress distribution in esthetic brackets differ among materials under the same wire load. Using the digital image correlation method, we discovered the following: (1) the strain of the wings of plastic brackets is within 0.2% and that of ceramic and metal brackets is negligible, (2) polycarbonate brackets having a stainless steel slot show significantly smaller displacement than other plastic brackets, and (3) there is a significant difference between plastic brackets and ceramic and stainless steel brackets in terms of the displacement of the bracket wing.

  11. Towards an Automated Development Methodology for Dependable Systems with Application to Sensor Networks

    NASA Technical Reports Server (NTRS)

    Hinchey, Michael G.; Rash, James L.; Rouff, Christopher A.

    2005-01-01

    A general-purpose method to mechanically transform system requirements into a probably equivalent model has yet to appeal: Such a method represents a necessary step toward high-dependability system engineering for numerous possible application domains, including sensor networks and autonomous systems. Currently available tools and methods that start with a formal model of a system and mechanically produce a probably equivalent implementation are valuable but not su8cient. The "gap" unfilled by such tools and methods is that their. formal models cannot be proven to be equivalent to the system requirements as originated by the customel: For the classes of systems whose behavior can be described as a finite (but significant) set of scenarios, we offer a method for mechanically transforming requirements (expressed in restricted natural language, or in other appropriate graphical notations) into a probably equivalent formal model that can be used as the basis for code generation and other transformations.

  12. Abuse notation of improper integrals

    NASA Astrophysics Data System (ADS)

    Arfi, E.; Wiryanto, L. H.

    2018-01-01

    In the definition of \\int_ab {f(x)dx} , it was assumed that the interval [a, b] was finite. However, in many application in physics, engineering, economics, and probability we wish to allow a or b (or both) to be infinite or for the other case when f has an infinite discontinuity in [a, b]. In either case the integral is called improper integral. Definition of improper integral is the limit of a definite integral as an endpoint of the interval of integration approaches either a specified real number or ∞ or -∞ or, in some cases, as both endpoints approach limits. Many of the first-year students in ITERA learning about improper integrals make an abuse notation like written improper integral just like standard definite integral. Based on this situation, we tried to change the habits of the students in the writing of improper integrals by providing sufficient understanding and considerable exercises. It turns out this way gives good result, based on the percentage of the value of the midterms to the problem of improper integrals give a fairly good percentage value.

  13. Data-mining to build a knowledge representation store for clinical decision support. Studies on curation and validation based on machine performance in multiple choice medical licensing examinations.

    PubMed

    Robson, Barry; Boray, Srinidhi

    2016-06-01

    Extracting medical knowledge by structured data mining of many medical records and from unstructured data mining of natural language source text on the Internet will become increasingly important for clinical decision support. Output from these sources can be transformed into large numbers of elements of knowledge in a Knowledge Representation Store (KRS), here using the notation and to some extent the algebraic principles of the Q-UEL Web-based universal exchange and inference language described previously, rooted in Dirac notation from quantum mechanics and linguistic theory. In a KRS, semantic structures or statements about the world of interest to medicine are analogous to natural language sentences seen as formed from noun phrases separated by verbs, prepositions and other descriptions of relationships. A convenient method of testing and better curating these elements of knowledge is by having the computer use them to take the test of a multiple choice medical licensing examination. It is a venture which perhaps tells us almost as much about the reasoning of students and examiners as it does about the requirements for Artificial Intelligence as employed in clinical decision making. It emphasizes the role of context and of contextual probabilities as opposed to the more familiar intrinsic probabilities, and of a preliminary form of logic that we call presyllogistic reasoning. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Does the bracket–ligature combination affect the amount of orthodontic space closure over three months? A randomized controlled trial

    PubMed Central

    Wong, Henry; Collins, Jill; Tinsley, David; Sandler, Jonathan; Benson, Philip

    2013-01-01

    Objective: To investigate the effect of bracket–ligature combination on the amount of orthodontic space closure over three months. Design: Randomized clinical trial with three parallel groups. Setting: A hospital orthodontic department (Chesterfield Royal Hospital, UK). Participants: Forty-five patients requiring upper first premolar extractions. Methods: Informed consent was obtained and participants were randomly allocated into one of three groups: (1) conventional pre-adjusted edgewise brackets and elastomeric ligatures; (2) conventional pre-adjusted edgewise brackets and Super Slick® low friction elastomeric ligatures; (3) Damon 3MX® passive self-ligating brackets. Space closure was undertaken on 0·019×0·025-inch stainless steel archwires with nickel–titanium coil springs. Participants were recalled at four weekly intervals. Upper alginate impressions were taken at each visit (maximum three). The primary outcome measure was the mean amount of space closure in a 3-month period. Results: A one-way ANOVA was undertaken [dependent variable: mean space closure (mm); independent variable: group allocation]. The amount of space closure was very similar between the three groups (1 mm per 28 days); however, there was a wide variation in the rate of space closure between individuals. The differences in the amount of space closure over three months between the three groups was very small and non-significant (P = 0·718). Conclusion: The hypothesis that reducing friction by modifying the bracket/ligature interface increases the rate of space closure was not supported. The major determinant of orthodontic tooth movement is probably the individual patient response. PMID:23794696

  15. Evaluation of mechanical properties of esthetic brackets

    PubMed Central

    Umezaki, Eisaku; Komazawa, Daigo; Otsuka, Yuichiro; Suda, Naoto

    2015-01-01

    Plastic brackets, as well as ceramic brackets, are used in various cases since they have excellent esthetics. However, their mechanical properties remain uncertain. The purpose of this study was to determine how deformation and stress distribution in esthetic brackets differ among materials under the same wire load. Using the digital image correlation method, we discovered the following: (1) the strain of the wings of plastic brackets is within 0.2% and that of ceramic and metal brackets is negligible, (2) polycarbonate brackets having a stainless steel slot show significantly smaller displacement than other plastic brackets, and (3) there is a significant difference between plastic brackets and ceramic and stainless steel brackets in terms of the displacement of the bracket wing. PMID:25755677

  16. An in vitro investigation on friction generated by ceramic brackets.

    PubMed

    Tecco, Simona; Teté, Stefano; Festa, Mario; Festa, Felice

    2010-01-01

    To compare friction (F) of conventional and ceramic brackets (0.022-inch slot) using a model that tests the sliding of the archwire through 10 aligned brackets. Polycrystalline alumina brackets (PCAs), PCA brackets with a stainless steel slot (PCA-M), and monocrystalline sapphire brackets (MCS) were tested under elastic ligatures using various archwires in dry and wet (saliva) states. Conventional stainless steel brackets were used as controls. In both dry and wet states, PCA and MCS brackets expressed a statistically significant higher F value with respect to stainless steel and PCA-M brackets when combined with the rectangular archwires (P<.01). PCA brackets showed significantly higher friction than MCS brackets (P<.01) when coupled with 0.014 x 0.025-inch nickel-titanium (Ni-Ti) archwire. SEM analysis showed differences in the surfaces among stainless steel, MCS, PCA-M, and PCA brackets. In the wet state, the mean F values were generally higher than in the dry state. PCA brackets showed significantly higher F than MCS brackets only when combined with 0.014 x 0.025-inch Ni-Ti archwires. Thus, in this study, a 10 aligned-brackets study model showed similar results when compared to a single bracket system except for friction level with 0.014 × 0.025-inch Ni-Ti archwires. © 2011 BY QUINTESSENCE PUBLISHING CO, INC.

  17. Effect of delayed polymerization time and bracket manipulation on orthodontic bracket bonding

    NASA Astrophysics Data System (ADS)

    Ponikvar, Michael J.

    This study examined the effect of bracket manipulation in combination with delayed polymerization times on orthodontic bracket shear bond strength and degree of resin composite conversion. Orthodontics brackets were bonded to extracted third molars in a simulated oral environment after a set period of delayed polymerization time and bracket manipulation. After curing the bracket adhesive, each bracket underwent shear bond strength testing followed by micro-Raman spectroscopy analysis to measure the degree of conversion of the resin composite. Results demonstrated the shear bond strength and the degree of conversion of ceramic brackets did not vary over time. However, with stainless steel brackets there was a significant effect (p ≤ 0.05) of delay time on shear bond strength between the 0.5 min and 10 min bracket groups. In addition, stainless steel brackets showed significant differences related to degree of conversion over time between the 0.5 min and 5 min groups, in addition to the 0.5 min and 10 min groups. This investigation suggests that delaying bracket adhesive polymerization up to a period of 10 min then adjusting the orthodontic bracket may increase both shear bond strength and degree of conversion of stainless steel brackets while having no effect on ceramic brackets.

  18. Crystallographic and Spectroscopic Symmetry Notations.

    ERIC Educational Resources Information Center

    Sharma, B. D.

    1982-01-01

    Compares Schoenflies and Hermann-Mauguin notations of symmetry. Although the former (used by spectroscopists) and latter (used by crystallographers) both describe the same symmetry, there are distinct differences in the manner of description which may lead to confusion in correlating the two notations. (Author/JN)

  19. Service Oriented Architecture for Coast Guard Command and Control

    DTIC Science & Technology

    2007-03-01

    Operations BPEL4WS The Business Process Execution Language for Web Services BPMN Business Process Modeling Notation CASP Computer Aided Search Planning...Business Process Modeling Notation ( BPMN ) provides a standardized graphical notation for drawing business processes in a workflow. Software tools

  20. Comparison of galvanic corrosion potential of metal injection molded brackets to that of conventional metal brackets with nickel-titanium and copper nickel-titanium archwire combinations.

    PubMed

    Varma, D Praveen Kumar; Chidambaram, S; Reddy, K Baburam; Vijay, M; Ravindranath, D; Prasad, M Rajendra

    2013-05-01

    The aim of the study is to investigate the galvanic corrosion potential of metal injection molding (MIM) brackets to that of conventional brackets under similar in vitro conditions with nickel-titanium and copper nickel-titanium archwires. Twenty-five maxillary premolar MIM stainless steel brackets and 25 conventional stainless steel brackets and archwires, 0.16 inch, each 10 mm length, 25 nickeltitanium wires, 25 copper nickel-titanium wires were used. They were divided into four groups which had five samples each. Combination of MIM bracket with copper nickel-titanium wire, MIM bracket with nickel-titanium wire and conventional stainless steel brackets with copper nickel-titanium wire and conventional stainless steel brackets with nickel-titanium wires which later were suspended in 350 ml of 1 M lactic acid solution media. Galvanic corrosion potential of four groups were analyzed under similar in vitro conditions. Precorrosion and postcorrosion elemental composition of MIM and conventional stainless steel bracket by scanning electron microscope (SEM) with energy dispersive spectroscope (EDS) was done. MIM bracket showed decreased corrosion susceptibility than conventional bracket with copper nickeltitanium wire. Both MIM and conventional bracket showed similar corrosion resistance potential in association with nickel-titanium archwires. It seems that both brackets are more compatible with copper nickel-titanium archwires regarding the decrease in the consequences of galvanic reaction. The EDS analysis showed that the MIM brackets with copper nickel-titanium wires released less metal ions than conventional bracket with copper nickeltitanium wires. MIM brackets showed decreased corrosion susceptibility, copper nickel-titanium archwires are compatible with both the brackets than nickel-titanium archwires. Clinically MIM and conventional brackets behaved more or less similarly in terms of corrosion resistance. In order to decrease the corrosion potential of MIM brackets, more precise manufacturing technique should be improved to get a more smoother surface finish.

  1. A formal MIM specification and tools for the common exchange of MIM diagrams: an XML-Based format, an API, and a validation method

    PubMed Central

    2011-01-01

    Background The Molecular Interaction Map (MIM) notation offers a standard set of symbols and rules on their usage for the depiction of cellular signaling network diagrams. Such diagrams are essential for disseminating biological information in a concise manner. A lack of software tools for the notation restricts wider usage of the notation. Development of software is facilitated by a more detailed specification regarding software requirements than has previously existed for the MIM notation. Results A formal implementation of the MIM notation was developed based on a core set of previously defined glyphs. This implementation provides a detailed specification of the properties of the elements of the MIM notation. Building upon this specification, a machine-readable format is provided as a standardized mechanism for the storage and exchange of MIM diagrams. This new format is accompanied by a Java-based application programming interface to help software developers to integrate MIM support into software projects. A validation mechanism is also provided to determine whether MIM datasets are in accordance with syntax rules provided by the new specification. Conclusions The work presented here provides key foundational components to promote software development for the MIM notation. These components will speed up the development of interoperable tools supporting the MIM notation and will aid in the translation of data stored in MIM diagrams to other standardized formats. Several projects utilizing this implementation of the notation are outlined herein. The MIM specification is available as an additional file to this publication. Source code, libraries, documentation, and examples are available at http://discover.nci.nih.gov/mim. PMID:21586134

  2. A formal MIM specification and tools for the common exchange of MIM diagrams: an XML-Based format, an API, and a validation method.

    PubMed

    Luna, Augustin; Karac, Evrim I; Sunshine, Margot; Chang, Lucas; Nussinov, Ruth; Aladjem, Mirit I; Kohn, Kurt W

    2011-05-17

    The Molecular Interaction Map (MIM) notation offers a standard set of symbols and rules on their usage for the depiction of cellular signaling network diagrams. Such diagrams are essential for disseminating biological information in a concise manner. A lack of software tools for the notation restricts wider usage of the notation. Development of software is facilitated by a more detailed specification regarding software requirements than has previously existed for the MIM notation. A formal implementation of the MIM notation was developed based on a core set of previously defined glyphs. This implementation provides a detailed specification of the properties of the elements of the MIM notation. Building upon this specification, a machine-readable format is provided as a standardized mechanism for the storage and exchange of MIM diagrams. This new format is accompanied by a Java-based application programming interface to help software developers to integrate MIM support into software projects. A validation mechanism is also provided to determine whether MIM datasets are in accordance with syntax rules provided by the new specification. The work presented here provides key foundational components to promote software development for the MIM notation. These components will speed up the development of interoperable tools supporting the MIM notation and will aid in the translation of data stored in MIM diagrams to other standardized formats. Several projects utilizing this implementation of the notation are outlined herein. The MIM specification is available as an additional file to this publication. Source code, libraries, documentation, and examples are available at http://discover.nci.nih.gov/mim.

  3. Effects of recycling and bonding agent application on bond strength of stainless steel orthodontic brackets.

    PubMed

    Bahnasi, Faisal I; Abd-Rahman, Aida Na; Abu-Hassan, Mohame I

    2013-10-01

    1) to assess different methods of recycling orthodontic brackets, 2) to evaluate Shear Bond Strength (SBS) of (a) new, (b) recycled and (c) repeated recycled stainless steel brackets (i) with and (ii) without bracket base primer. A total of 180 extracted human premolar teeth and 180 premolar stainless steel brackets were used. One hundred teeth and 100 brackets were divided into five groups of 20-teeth each. Four methods of recycling orthodontic brackets were used in each of the first four groups while the last one (group V) was used as the control. Groups (I-V) were subjected to shear force within half an hour until the brackets debond. SBS was measured and the method showing the highest SBS was selected. A New group (VI) was recycled twice with the selected method. Six subgroups (1-6) were established; the primer was applied for three sub-groups, and the composite was applied for all brackets. Brackets were subjected to the same shear force, and SBS was measured for all sub-groups. There was a significant difference between the mean SBS of the sandblasting method and the means of SBS of each of the other three methods. There was however, no significant difference between the mean SBS of the new bracket and the mean SBS of recycled bracket using sandblasting. The mean SBS of all sub-groups were more than that recommended by Reynolds (17) in 1975. Brackets with primer showed slightly higher SBS compared to those of brackets without bonding agent. To decrease cost, sandblasted recycled orthodontic brackets can be used as an alternative to new brackets. It is recommended to apply a bonding agent on the bracket base to provide greater bond strength. Key words:Recycled bracket, shear bond strength, sandblasting, stainless steel orthodontic bracket.

  4. The practical and pedagogical advantages of an ambigraphic nucleic acid notation.

    PubMed

    Rozak, David A

    2006-01-01

    The universally applied IUPAC notation for nucleic acids was adopted primarily to facilitate the mental association of G, A, T, C, and the related ambiguity characters with the bases they represent. However it is possible to create a notation that offers greater support for the basic manipulations and analyses to which genetic sequences frequently are subjected. By designing a nucleic acid notation around ambigrams, it is possible to simplify the frequently applied process of reverse complementation and aid the visualization of palindromes. The ambigraphic notation presented here also uses common orthographic features such as stems and loops to highlight guanine and cytosine rich regions, support the derivation of ambiguity characters, and aid educators in teaching the fundamentals of molecular genetics.

  5. Surface chemical composition of human maxillary first premolar as assessed by X-ray photoelectron spectroscopy (XPS)

    NASA Astrophysics Data System (ADS)

    Lou, Leo; Nelson, Alan E.; Heo, Giseon; Major, Paul W.

    2008-08-01

    The surface chemical composition of dental enamel has been postulated as a contributing factor in the variation of bond strength of brackets bonded to teeth, and hence, the probability of bracket failure during orthodontic treatment. This study systematically investigated the chemical composition of 98 bonding surfaces of human maxillary premolars using X-ray photoelectron spectroscopy (XPS) to ascertain compositional differences between right and left first premolars. The major elements detected in all samples were calcium, phosphorus, oxygen, nitrogen and carbon. Surface compositions were highly variable between samples and several elements were found to be highly correlated. No statistical significant difference in the chemical composition of the maxillary right and left first premolars was found ( p > 0.05). Knowledge of the chemical composition of enamel surfaces will facilitate future studies that relate this information to the variations in dental enamel bond strength.

  6. The Moon System Adapted for Musical Notation.

    ERIC Educational Resources Information Center

    Jackson, Michael

    1987-01-01

    A means is presented for using William Moon's embossed symbols to represent musical notation for blind individuals, as an alternative to braille notation. The proposed system includes pitch symbols, octave indicators, duration symbols, accidentals, key signatures, rests, stress symbols, ornaments, and other symbols. (Author/JDD)

  7. Coated Rectangular Composite Archwires: A Comparison Of Self-Ligating And Conventional Bracket Systems During Sliding Mechanics

    NASA Astrophysics Data System (ADS)

    Woods, David Keith

    The purpose of this study was to analyze the resistance to sliding of coated rectangular fiber reinforced composite archwires using various brackets systems and second-order bracket angulations. Resistance to sliding was investigated for eight bracket systems: six self-ligating brackets (four passive and two passive-active) and two conventional brackets. A rectangular fiber reinforced composite archwire of 0.019 x 0.025-in dimension from BiomersRTM SimpliClear was drawn through a three-bracket model system at ten millimeters per minute for 2.5 millimeters. For each bracket, the resistance to sliding was measured at four bracket angulations (0°, 2.5°, 5°, and 10°) in a dry state at room temperature. The fiber reinforced composite archwire produced the lowest sliding resistance with the passive self-ligating bracket system (Damon DQ) at each bracket angulation tested. Overall, self-ligating bracket systems generated lower sliding resistance than conventionally ligated systems, and one passive/active self-ligating bracket system (In-Ovation-R). There was a significant increase in resistance to sliding as bracket angulation increased for all bracket systems tested. Microscopic analysis revealed increased perforation of the archwire coating material as bracket angulations were increased. Our findings show that the rectangular fiber reinforced composite archwire may be acceptable for sliding mechanics during the intermediate stages of orthodontic tooth movement, however more long-term studies are needed.

  8. Assessment of Ions released from Three Types of Orthodontic Brackets immersed in Different Mouthwashes: An in vitro Study.

    PubMed

    Nahidh, Mohammed; Garma, Noor Mh; Jasim, Esraa S

    2018-01-01

    Herbs are used widely in medicine. The purpose of the present study was to assess the ion release from gold-plated orthodontic bracket compared with other stainless steel brackets, and based on the findings of the study, the orthodontists can choose the most biocompatible brackets and mouthwashes useful in the clinical practice. A total of 150 orthodontic brackets from Orthotechnology™ Company, USA (50 stainless steel one-piece brackets, 50 stainless steel two-piece brackets, and 50 gold brackets) were immersed in four mouthwashes in addition to distilled water. Ten of each type of brackets in every media were immersed under 37°C for 45 days. Ions released in these mouthwashes were measured, and comparisons among different bracket types and among various mouthwashes were done by one-way analysis of variance (ANOVA) and then with Games-Howell tests. Increased amounts of ions released in herbal mouth-washes were recorded in gold and two-piece brackets in comparison with one-piece stainless steel brackets. Herbal mouthwashes must be used with caution as they showed an increased amount of ions released in comparison with chlorhexidine. One-piece stainless steel bracket system is the most compatible bracket type, as they released the least amount of ions. One-piece stainless steel brackets are better than two-piece brackets in terms of ions released.

  9. Investigating and improving student understanding of quantum mechanical observables and their corresponding operators in Dirac notation

    NASA Astrophysics Data System (ADS)

    Marshman, Emily; Singh, Chandralekha

    2018-01-01

    In quantum mechanics, for every physical observable, there is a corresponding Hermitian operator. According to the most common interpretation of quantum mechanics, measurement of an observable collapses the quantum state into one of the possible eigenstates of the operator and the corresponding eigenvalue is measured. Since Dirac notation is an elegant notation that is commonly used in upper-level quantum mechanics, it is important that students learn to express quantum operators corresponding to observables in Dirac notation in order to apply the quantum formalism effectively in diverse situations. Here we focus on an investigation that suggests that, even though Dirac notation is used extensively, many advanced undergraduate and PhD students in physics have difficulty expressing the identity operator and other Hermitian operators corresponding to physical observables in Dirac notation. We first describe the difficulties students have with expressing the identity operator and a generic Hermitian operator corresponding to an observable in Dirac notation. We then discuss how the difficulties found via written surveys and individual interviews were used as a guide in the development of a quantum interactive learning tutorial (QuILT) to help students develop a good grasp of these concepts. The QuILT strives to help students become proficient in expressing the identity operator and a generic Hermitian operator corresponding to an observable in Dirac notation. We also discuss the effectiveness of the QuILT based on in-class evaluations.

  10. Notation Confusion of Symmetry Species for Molecules with Several Large-Amplitude Internal Motions

    NASA Astrophysics Data System (ADS)

    Groner, P.

    2011-06-01

    The Mulliken convention has become the standard notation for symmetry species (irreducible representations) of point groups for quasi-rigid molecules. No such convention exists for symmetry species of symmetry groups for semi-rigid or non-rigid molecules with large amplitude internal motions (LAMs). As a result, we have a situation where we create notations in a do-it-yourself fashion or adopt them from the literature, sometimes even without proper reference to its derivation or to the character table on which it is based. This may be just a nuisance for those who are comfortable enough with group theory and molecular symmetry groups to figure "it" out, but it represents a real problem for everybody else. The notation confusion is illustrated with examples from the literature (both old and new) on molecules with two or more LAMs. Most authors use the notation introduced by Myers and Wilson for molecules such as acetone or propane. No universal notation is in use for molecules with two methyl groups but lower overall symmetry. For example, the notation G_1_8 is used for one of these groups. As it turns out, different people use the same notation for different groups. This presentation is an attempt to bring some light into the dark and to combat confusion with a call for an anti-confusion convention. R. S. Mulliken, Phys. Rev. 43, 279 (1933). R. J. Myers, E. B. Wilson, J. Chem. Phys. 33, 186 (1960).

  11. The fracture strength of ceramic brackets: a comparative study.

    PubMed

    Flores, D A; Caruso, J M; Scott, G E; Jeiroudi, M T

    1990-01-01

    Recent demand for esthetic brackets has led to the development and use of ceramic brackets in orthodontics. The purpose of this study was to compare the fracture strength of different ceramic brackets under different surface conditions and ligation methods using a torsional wire bending force. Five different bracket types (two polycrystalline, two single-crystal, and one metal) were tested using elastic and wire ligation, with half being scratched and the other half remaining unscratched. Results showed a significant difference between bracket types and surface conditions. Non-scratched single-crystal brackets had higher fracture strengths and slightly higher fracture loads than polycrystalline brackets. However, single-crystal brackets were significantly adversely affected by surface damage (scratching), while polycrystalline brackets were not significantly affected by surface damage. The fracture behavior of ceramic brackets followed the Griffith model where fracture strength decreased following surface damage.

  12. Comparison of the force levels among labial and lingual self-ligating and conventional brackets in simulated misaligned teeth.

    PubMed

    Alobeid, Ahmad; El-Bialy, Tarek; Khawatmi, Said; Dirk, Cornelius; Jäger, Andreas; Bourauel, Christoph

    2017-08-01

    The aim of this study was to evaluate force levels exerted by levelling arch wires with labial and lingual conventional and self-ligating brackets. The tested orthodontic brackets were of the 0.022-in slot size for labial and 0.018-in for lingual brackets and were as follows: 1. Labial brackets: (i) conventional bracket (GAC-Twin, Dentsply), (ii) passive self-ligating (SL) brackets (Damon-Q®, ORMCO; Ortho classic H4™, Orthoclassic; FLI®SL, Rocky Mountain Orthodontics) and (iii) active SL brackets (GAC In-Ovation®C, DENTSPLY and SPEED™, Strite). 2. Lingual brackets: (i) conventional brackets (Incognito, 3M and Joy™, Adenta); (ii) passive SL bracket (GAC In-Ovation®LM™, Dentsply and (iii) active SL bracket (Evolution SLT, Adenta). Thermalloy-NiTi 0.013-in and 0.014-in arch wires (Rocky Mountain Orthodontics) were used with all brackets. The simulated malocclusion represented a maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). Lingual bracket systems showed higher force levels (2.4 ± 0.2 to 3.8 ± 0.2 N) compared to labial bracket systems (from 1.1 ± 0.1 to 2.2 ± 0.4 N). However, the differences between SL and conventional bracket systems were minor and not consistent (labial brackets: 1.2 ± 0.1 N for the GAC Twin and 1.1 ± 0.1 to 1.6 ± 0.1 N for the SL brackets with 0.013-in thermalloy; lingual brackets: 2.5 ± 0.2 to 3.5 ± 0.1 N for the conventional and 2.7 ± 0.3 to 3.4 ± 0.1 N for the SL brackets with 0.013-in Thermalloy). This is an in vitro study with different slot sizes in the labial and lingual bracket systems, results should be interpreted with caution. Lingual bracket systems showed higher forces compared to labial bracket systems that might be of clinical concern. We recommend highly flexible nickel titanium arch wires lower than 0.013-in for the initial levelling and alignment especially with lingual appliances. © The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  13. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    PubMed Central

    MONTEIRO, Maria Regina Guerra; da SILVA, Licinio Esmeraldo; ELIAS, Carlos Nelson; VILELLA, Oswaldo de Vasconcellos

    2014-01-01

    Objective To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric ligatures (TP Orthodontics) were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M). The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil). The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material. PMID:25025564

  14. Are Arabic and Verbal Numbers Processed in Different Ways?

    ERIC Educational Resources Information Center

    Kadosh, Roi Cohen; Henik, Avishai; Rubinsten, Orly

    2008-01-01

    Four experiments were conducted in order to examine effects of notation--Arabic and verbal numbers--on relevant and irrelevant numerical processing. In Experiment 1, notation interacted with the numerical distance effect, and irrelevant physical size affected numerical processing (i.e., size congruity effect) for both notations but to a lesser…

  15. Scientific Notation Watercolor

    ERIC Educational Resources Information Center

    Linford, Kyle; Oltman, Kathleen; Daisey, Peggy

    2016-01-01

    (Purpose) The purpose of this paper is to describe visual literacy, an adapted version of Visual Thinking Strategy (VTS), and an art-integrated middle school mathematics lesson about scientific notation. The intent of this lesson was to provide students with a real life use of scientific notation and exponents, and to motivate them to apply their…

  16. A Notation for Rapid Specification of Information Visualization

    ERIC Educational Resources Information Center

    Lee, Sang Yun

    2013-01-01

    This thesis describes a notation for rapid specification of information visualization, which can be used as a theoretical framework of integrating various types of information visualization, and its applications at a conceptual level. The notation is devised to codify the major characteristics of data/visual structures in conventionally-used…

  17. Symbolic, Nonsymbolic and Conceptual: An Across-Notation Study on the Space Mapping of Numerals.

    PubMed

    Zhang, Yu; You, Xuqun; Zhu, Rongjuan

    2016-07-01

    Previous studies suggested that there are interconnections between two numeral modalities of symbolic notation and nonsymbolic notation (array of dots), differences and similarities of the processing, and representation of the two modalities have both been found in previous research. However, whether there are differences between the spatial representation and numeral-space mapping of the two numeral modalities of symbolic notation and nonsymbolic notation is still uninvestigated. The present study aims to examine whether there are differences between the spatial representation and numeral-space mapping of the two numeral modalities of symbolic notation and nonsymbolic notation; especially how zero, as both a symbolic magnitude numeral and a nonsymbolic conceptual numeral, mapping onto space; and if the mapping happens automatically at an early stage of the numeral information processing. Results of the two experiments demonstrate that the low-level processing of symbolic numerals including zero and nonsymbolic numerals except zero can mapping onto space, whereas the low-level processing of nonsymbolic zero as a semantic conceptual numeral cannot mapping onto space, which indicating the specialty of zero in the numeral domain. The present study indicates that the processing of non-semantic numerals can mapping onto space, whereas semantic conceptual numerals cannot mapping onto space. © The Author(s) 2016.

  18. Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.

    PubMed

    Pasha, Azam; Vishwakarma, Swati; Narayan, Anjali; Vinay, K; Shetty, Smitha V; Roy, Partha Pratim

    2015-09-01

    Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conventional, (metal and ceramic) brackets using unconventional and conventional ligation system, and the self-ligating (metal and ceramic) brackets in the dry condition. The various bracket wire ligation combinations were tested in dry condition. The brackets used were of 0.022″ × 0.028″ nominal slot dimension of MBT prescription: Stainless steel (SS) self-ligating bracket (SLB) of (SmartClip), SS Conventional bracket (CB) (Victory series), Ceramic SLB (Clarity SL), Conventional Ceramic bracket with metal slot (Clarity Bracket), Clarity Advanced Ceramic Brackets (Clarity(™) ADVANCED, 3M Unitek). These brackets were used with two types of elastomeric ligatures: Conventional Elastomeric Ligatures (CEL) (Clear medium mini modules) and Unconventional Elastomeric Ligatures (UEL) (Clear medium slide ligatures, Leone orthodontic products). The aligning and the retraction wires were used, i.e., 0.014″ nickel titanium (NiTi) wires and 0.019″ × 0.025″ SS wires, respectively. A universal strength testing machine was used to measure the friction produced between the different bracket, archwires, and ligation combination. This was done with the use of a custom-made jig being in position. Mean, standard deviation, and range were computed for the frictional values obtained. Results were subjected to statistical analysis through ANOVA. The frictional resistance observed in the new Clarity Advanced bracket with a conventional elastomeric ligature was almost similar with the Clarity metal slot bracket with a conventional elastomeric ligature. When using the UEL, the Clarity Advanced bracket produced lesser friction than the conventional metal bracket; but not less than the ceramic metal slot bracket. Ceramic SLB produced lesser friction when compared with the Clarity Advanced bracket with UEL, but the metal SLB produced the least friction among all the groups and subgroups. The present study concluded that the SS SLB produced least friction among all groups. Using the archwire and ligation method, frictional forces observed in the Clarity Advanced bracket and the conventional ceramic with metal slot bracket were almost similar; but the least resistance was determined in SS CB using both the ligation (CEL and UEL) system.

  19. Effects of recycling and bonding agent application on bond strength of stainless steel orthodontic brackets

    PubMed Central

    Bahnasi, Faisal I.; Abu-Hassan, Mohame I.

    2013-01-01

    Objectives: 1) to assess different methods of recycling orthodontic brackets, 2) to evaluate Shear Bond Strength (SBS) of (a) new, (b) recycled and (c) repeated recycled stainless steel brackets (i) with and (ii) without bracket base primer. Study Design: A total of 180 extracted human premolar teeth and 180 premolar stainless steel brackets were used. One hundred teeth and 100 brackets were divided into five groups of 20-teeth each. Four methods of recycling orthodontic brackets were used in each of the first four groups while the last one (group V) was used as the control. Groups (I-V) were subjected to shear force within half an hour until the brackets debond. SBS was measured and the method showing the highest SBS was selected. A New group (VI) was recycled twice with the selected method. Six subgroups (1-6) were established; the primer was applied for three sub-groups, and the composite was applied for all brackets. Brackets were subjected to the same shear force, and SBS was measured for all sub-groups. Results: There was a significant difference between the mean SBS of the sandblasting method and the means of SBS of each of the other three methods. There was however, no significant difference between the mean SBS of the new bracket and the mean SBS of recycled bracket using sandblasting. The mean SBS of all sub-groups were more than that recommended by Reynolds (17) in 1975. Brackets with primer showed slightly higher SBS compared to those of brackets without bonding agent. Conclusion: To decrease cost, sandblasted recycled orthodontic brackets can be used as an alternative to new brackets. It is recommended to apply a bonding agent on the bracket base to provide greater bond strength. Key words:Recycled bracket, shear bond strength, sandblasting, stainless steel orthodontic bracket. PMID:24455081

  20. PGI Bracket Positioner: A Novel Combination of Reverse Bracket Tweezer and Positioning Gauze.

    PubMed

    Singh, Sombir; Verma, Sanjeev; Bhupali, Nameksh Raj; Singh, Satinder Pal

    2018-01-01

    The accurate bracket positioning is essential for the expression of the bracket system that affects the treatment outcome considerably and is also essential for good functional occlusion as well as facial esthetics. The proper alignment cannot be achieved without proper bracket positioning. Thus, the brackets positioning devices are an integral part of orthodontic armamentarium. Here, we present a new innovation that provides a unique combination of reverse bracket tweezer and positioner and hence is very helpful in precise vertical positioning of brackets with increased efficiency.

  1. Air-powder polishing on self-ligating brackets after clinical use: effects on debris levels.

    PubMed

    Aragón, Mônica L S Castro; Lima, Leandro Santiago; Normando, David

    2016-01-01

    Debris buildup on brackets and arch surfaces is one of the main factors that can influence the intensity of friction between bracket and orthodontic wire. This study sought to evaluate the effect of air-powder polishing cleaning on debris levels of self-ligating ceramic brackets at the end of orthodontic treatment, compared to the behavior of conventional brackets. Debris levels were evaluated in metal conventional orthodontic brackets (n = 42) and ceramic self-ligating brackets (n = 42) on canines and premolars, arranged in pairs. There were brackets with and without air-powder polishing. At the end of orthodontic treatment, a hemiarch served as control and the contralateral hemiarch underwent prophylaxis with air-powder polishing. Debris buildup in bracket slots was assessed through images, and Wilcoxon test was used to analyze the results. The median debris levels were statistically lower in the conventional metal brackets compared to self-ligating ones (p = 0.02), regarding brackets not submitted to air-powder polishing. Polishing significantly reduced debris buildup to zero in both systems, without differences between groups. Ceramic self-ligating brackets have a higher debris buildup in comparison to conventional metal brackets in vivo, but prophylaxis with sodium bicarbonate jet was effective in reducing debris levels in self-ligating and also in conventional brackets.

  2. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review

    PubMed Central

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    Background To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Material and Methods Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). Results In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conclusions Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words:Systematic review, self ligation, torque expression, conventional ligation. PMID:28149476

  3. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review.

    PubMed

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words: Systematic review, self ligation, torque expression, conventional ligation.

  4. Comparison of the efficacy of tooth alignment among lingual and labial brackets: an in vitro study.

    PubMed

    Alobeid, Ahmad; El-Bialy, Tarek; Reimann, Susanne; Keilig, Ludger; Cornelius, Dirk; Jäger, Andreas; Bourauel, Christoph

    2018-03-13

    The aim of this study was to evaluate the efficacy of tooth alignment with conventional and self-ligating labial and lingual orthodontic bracket systems. We tested labial brackets (0.022″ slot size) and lingual brackets (0.018″ slot size). The labial brackets were: (i) regular twin brackets (GAC-Twin [Dentsply]), (ii) passive self-ligating brackets including (Damon-Q® [ORMCO]; Ortho classic H4™ [Orthoclassic]; FLI®SL [RMO]), and (iii) active self-ligating brackets (GAC In-Ovation®C [DENTSPLY] and SPEED™[Strite]). The lingual brackets included (i) twin bracket systems (Incognito [3M] and Joy™ [Adenta]), (ii) passive self-ligating bracket system (GAC In-Ovation®LM™ [Dentsply]), and (iii) active self-ligating bracket system (Evolution SLT [Adenta]). The tested wires were Thermalloy-NiTi 0.013″ and 0.014″ (RMO). The archwires were tied to the regular twin brackets with stainless steel ligatures 0.010″ (RMO). The malocclusion simulated a displaced maxillary central incisor in the x-axis (2 mm gingivally) and in the z-axis (2 mm labially). The results showed that lingual brackets are less efficient in aligning teeth when compared with labial brackets in general. The vertical correction achieved by labial bracket systems ranged from 72 to 95 per cent with 13″ Thermalloy wires and from 70 to 87 per cent with 14″ Thermalloy wires. In contrast, the achieved corrections by lingual brackets with 13″ Thermalloy wires ranged between 25-44 per cent and 29-52 per cent for the 14" Thermalloy wires. The anteroposterior correction achieved by labial brackets ranged between 83 and 138 per cent for the 13″ Thermalloy and between 82 and 129 per cent for the 14″ Thermalloy wires. On the other hand, lingual brackets corrections ranged between 12 and 40 per cent for the 13″ Thermalloy wires and between 30 and 45 per cent for the 14″ Thermalloy wires. This is a lab-based study with different labial and lingual bracket slot sizes (however they are the commonly used ones in clinical orthodontics) and study did not consider saliva, periodontal ligament, mastication and other oral functions. The effectiveness of lingual brackets in correcting vertical and anteroposterior displacement achieved during the initial alignment phase of orthodontic treatment is lower than that of the effectiveness of labial brackets.

  5. Does the design of self-ligating brackets show different behavior in terms of friction?

    PubMed

    Tecco, Simona; Marzo, Giuseppe; Di Bisceglie, Beatrice; Crincoli, Vito; Tetè, Stefano; Festa, Felice

    2011-01-01

    This in vitro study evaluated the friction generated by aligned stainless steel conventional brackets, self-ligating Damon MX brackets, Time3 brackets, Vision LP brackets, and low-friction Slide ligatures coupled with various stainless steel, nickel-titanium (Ni-Ti), and beta-titanium (TMA) archwires. All brackets had a 0.022-inch slot; the orthodontic archwires were 0.014-inch Ni-Ti, 0.016-inch Ni-Ti, 0.014 x 0.025-inch Ni-Ti, 0.018 x 0.025-inch Ni-Ti, 0.017 x 0.025-inch TMA, 0.019 x 0.025-inch stainless steel, and 0.019 x 0.025-inch Ni-Ti. Each bracket-archwire combination was tested 10 times. Coupled with 0.014-inch Ni-Ti and 0.016-inch Ni-Ti archwire, conventional brackets generated the greatest friction, while Damon MX and Vision LP brackets generated the lowest (P < .05). No significant difference was observed between Time3 brackets and Slide ligatures. Coupled with all the rectangular archwires, Victory Series brackets, Slide ligatures, and Vision LP self-ligating brackets generated significantly lower friction than Time3 and Damon MX self-ligating brackets (P < .05). These findings suggest that self-ligating brackets are a great family of brackets that, in vitro, can generate different levels of friction when coupled with thin, thick, rectangular, or round archwires. Clinical conclusions based on our results are not possible, due to the limitations of the experimental conditions.

  6. Adhesive performance of precoated brackets after expiration.

    PubMed

    Cloud, Cayce C; Trojan, Terry M; Suliman, Sam N; Tantbirojn, Daranee; Versluis, Antheunis

    2016-03-01

    To evaluate adhesive performance in terms of debonding forces of precoated metal and ceramic brackets 4 years after expiration. Buccal and lingual surfaces of embedded extracted maxillary premolars were etched with 34% Tooth Conditioner Gel (Dentsply Caulk, Milford, Del), rinsed, and dried. Transbond MIP (3M Unitek, Monrovia, Calif) was applied prior to placing adhesive precoated brackets (APC II Victory stainless steel and APC Plus Clarity ceramic brackets, 3M Unitek). The preexpiration brackets had 29-35 months before, and the postexpiration brackets were 45-52 months past, their expiration dates. Sample size was 17-21 per group. Debonding forces were determined by subjecting the bonded brackets to a shear force in a universal testing machine. Debonding forces were compared using two-way ANOVA. Debonded surfaces were examined under a stereomicroscope to determine failure modes, which were compared using the chi-square test. No statistically significant difference was found in debonding forces (P  =  .8581) or failure modes (P  =  .4538) between expired and unexpired brackets. Metal brackets required statistically significantly higher debonding forces than did ceramic brackets (P  =  .0001). For both expired and unexpired brackets, failure modes were mostly cohesive in the adhesive layer for ceramic brackets, and mixed between adhesive and cohesive failure in the adhesive layer for metal brackets. Adhesive precoated brackets did not have any reduction in enamel-adhesion properties up to 4 years after their expiration date. Extended shelf life testing for precoated dental brackets may be worth considering.

  7. Linking Different Cultures by Computers: A Study of Computer-Assisted Music Notation Instruction.

    ERIC Educational Resources Information Center

    Chen, Steve Shihong; Dennis, J. Richard

    1993-01-01

    Describes a study that investigated the feasibility of using computers to teach music notation systems to Chinese students, as well as to help Western educators study Chinese music and its number notation system. Topics discussed include students' learning sequences; HyperCard software; hypermedia and graphic hypertext indexing; and the…

  8. Using Graphical Notations to Assess Children's Experiencing of Simple and Complex Musical Fragments

    ERIC Educational Resources Information Center

    Verschaffel, Lieven; Reybrouck, Mark; Janssens, Marjan; Van Dooren, Wim

    2010-01-01

    The aim of this study was to analyze children's graphical notations as external representations of their experiencing when listening to simple sonic stimuli and complex musical fragments. More specifically, we assessed the impact of four factors on children's notations: age, musical background, complexity of the fragment, and most salient…

  9. Speechant: A Vowel Notation System to Teach English Pronunciation

    ERIC Educational Resources Information Center

    dos Reis, Jorge; Hazan, Valerie

    2012-01-01

    This paper introduces a new vowel notation system aimed at aiding the teaching of English pronunciation. This notation system, designed as an enhancement to orthographic text, was designed to use concepts borrowed from the representation of musical notes and is also linked to the acoustic characteristics of vowel sounds. Vowel timbre is…

  10. Using Design Principles to Consider Representation of the Hand in Some Notation Systems

    ERIC Educational Resources Information Center

    Hochgesang, Julie A.

    2014-01-01

    Linguists have long recognized the descriptive limitations of Stokoe notation, currently the most commonly used system for phonetic or phonological transcription, but continue using it because of its widespread influence (e.g., Siedlecki and Bonvillian, 2000). With the emergence of newer notation systems, the field will benefit from a discussion…

  11. Monograph On Tensor Notations

    NASA Technical Reports Server (NTRS)

    Sirlin, Samuel W.

    1993-01-01

    Eight-page report describes systems of notation used most commonly to represent tensors of various ranks, with emphasis on tensors in Cartesian coordinate systems. Serves as introductory or refresher text for scientists, engineers, and others familiar with basic concepts of coordinate systems, vectors, and partial derivatives. Indicial tensor, vector, dyadic, and matrix notations, and relationships among them described.

  12. Music-Notation Searching and Digital Libraries.

    ERIC Educational Resources Information Center

    Byrd, Donald

    Almost all work on music information retrieval to date has concentrated on music in the audio and event (normally MIDI) domains. However, music in the form of notation, especially Conventional Music Notation (CMN), is of much interest to musically trained persons, both amateurs and professionals, and searching CMN has great value for digital music…

  13. Skin notation in the context of workplace exposure standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scansetti, G.; Piolatto, G.; Rubino, G.F.

    1988-01-01

    In the establishment of workplace exposure standards, the potential for cutaneous absorption is taken into consideration through the addition of skin notation to the relevant substance. In the TLVs Documentation (ACGIH, 1986) dermal lethal dose to 50% (LD50) or human data are the bases for the assignment of skin notation to 91 of 168 substances. For the other substances, the skin attribution seems to be based on undocumented statements in 24 (14.5%), skin effects in 13 (8%), and analogy in 7 (4%), while in the remaining 33 (20%) any reference is lacking as to the basis for notation of themore » cutaneous route of entry. Furthermore, since the established cut-off value of 2 g/kg is sometimes bypassed when a notation is added or omitted, the use of dermal LD50 is perplexing. Given the relevance of the skin notation for the validation of threshold limit values (TLVs) in the workplace, a full examination and citation of all available scientific data are recommended when establishing the TLV of substances absorbable through the skin.« less

  14. Rational-number comparison across notation: Fractions, decimals, and whole numbers.

    PubMed

    Hurst, Michelle; Cordes, Sara

    2016-02-01

    Although fractions, decimals, and whole numbers can be used to represent the same rational-number values, it is unclear whether adults conceive of these rational-number magnitudes as lying along the same ordered mental continuum. In the current study, we investigated whether adults' processing of rational-number magnitudes in fraction, decimal, and whole-number notation show systematic ratio-dependent responding characteristic of an integrated mental continuum. Both reaction time (RT) and eye-tracking data from a number-magnitude comparison task revealed ratio-dependent performance when adults compared the relative magnitudes of rational numbers, both within the same notation (e.g., fractions vs. fractions) and across different notations (e.g., fractions vs. decimals), pointing to an integrated mental continuum for rational numbers across notation types. In addition, eye-tracking analyses provided evidence of an implicit whole-number bias when we compared values in fraction notation, and individual differences in this whole-number bias were related to the individual's performance on a fraction arithmetic task. Implications of our results for both cognitive development research and math education are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. Study of force loss due to friction comparing two ceramic brackets during sliding tooth movement.

    PubMed

    AlSubaie, Mai; Talic, Nabeel; Khawatmi, Said; Alobeid, Ahmad; Bourauel, Christoph; El-Bialy, Tarek

    2016-09-01

    To compare the percentage of force loss generated during canine sliding movements in newly introduced ceramic brackets with metal brackets. Two types of ceramic brackets, namely polycrystalline alumina (PCA) ceramic brackets (Clarity Advanced) and monocrystalline alumina (MCA) ceramic brackets (Inspire Ice) were compared with stainless steel (SS) brackets (Victory Series). All bracket groups (n = 5 each) were for the maxillary canines and had a 0.018-inch slot size. The brackets were mounted on an Orthodontic Measurement and Simulation System (OMSS) to simulate the canine retraction movement into the first premolar extraction space. Using elastic ligatures, 0.016 × 0.022″ (0.40 × 0.56 mm) stainless steel archwires were ligated onto the brackets. Retraction force was applied via a nickel-titanium coil spring with a nearly constant force of approximately 1 N. The OMSS measured the percentage of force loss over the retraction path by referring to the difference between the applied retraction force and actual force acting on each bracket. Between group comparisons were done with one-way analysis of variance. The metal brackets revealed the lowest percentage of force loss due to friction, followed by the PCA and MCA ceramic bracket groups (67 ± 4, 68 ± 7, and 76 ± 3 %, respectively). There was no significant difference between SS and PCA brackets (p = 0.97), but we did observe significant differences between metal and MCA brackets (p = 0.03) and between PCA and MCA ceramic brackets (p = 0.04). PCA ceramic brackets, whose slot surface is covered with an yttria-stabilized zirconia-based coating exhibited frictional properties similar to those of metal brackets. Frictional resistance resulted in an over 60 % loss of the applied force due to the use of elastic ligatures.

  16. The Effects of In-Office Reconditioning on the Slot Dimensions and Static Frictional Resistance of Stainless Steel Brackets

    PubMed Central

    Nellore, Chaitanya; Karnati, Praveen Kumar Reddy; Thalapaneni, Ashok Kumar; Myla, Vijay Bhaskar; Ramyasree, Konda; Prasad, Mandava

    2016-01-01

    Introduction Orthodontists are commonly faced with the decision of what to do with loose brackets, and with inaccurately located brackets that need repositioning during treatment. One solution is to recycle the brackets. The potential effects of reconditioning a bracket are dependent upon many factors which may result in physical changes like alteration in slot tolerance, which may influence sliding mechanics by affecting frictional resistance. Aim To study and compare the dimensional changes in the bracket slot width and depth in reconditioned brackets from unused brackets under scanning electronic microscope and to study and compare any consequent effects on the static frictional resistance of stainless steel brackets after reconditioning and in unused brackets. Materials and Methods Dentarum manufactured 90 stainless steel central incisors edgewise brackets of size 0.22 X 0.030″ inch and 0° tip and 0°angulation were taken. 60 samples for measuring frictional resistance and 30 samples for measuring slot dimensions. Ortho organizers manufactured stainless steel arch wires 0.019 X 0.025″ straight lengths 60 in number were considered for measuring static frictional resistance. Results The mean slot width and depth of new brackets were 0.0251″ and 0.0471″, which exceeded the manufacturers reported nominal size of 0.022″ X 0.030″, by 0.003″ and 0.017″. The reconditioned brackets demonstrated a further increase in mean slot width and depth to 0.028″ and 0.0518″ that is by 0.0035″ and 0.0047″ which is statistically significant (p=0.001, 0.002). The mean static frictional forces of the reconditioned brackets was nearly similar to that of new brackets that is 0.3167N for reconditioned brackets and 0.2613 N for new brackets. Conclusion Although the reconditioning process results in physical changes to bracket structure this does not appear to result in significant effect on ex-vivo static frictional resistance. PMID:26894182

  17. Assessment of Bracket Surface Morphology and Dimensional Change

    PubMed Central

    Radhakrishnan, Pillai Devu; Sapna Varma, N. K.; Ajith, V. V.

    2017-01-01

    Objective: The objective of this study was to compare the surface morphology and dimensional stability of the bracket slot at the onset of treatment and after 12 months of intraoral exposure. The study also compared the amount of calcium at the bracket base which indicates enamel loss among the three orthodontic brackets following debonding after 12 months of intraoral exposure. Materials and Methods: The sample consisted of 60 (0.022” MBT) canine brackets. They were divided into three groups: self-ligating, ceramic bracket with metal slot, and stainless steel (SS) brackets. The slot dimensions, micromorphologic characteristics of as-received and retrieved brackets were measured with a stereomicroscope and scanning electron microscope (SEM), respectively. The amount of calcium at the bracket base which indicates enamel damage was quantified using energy-dispersive X-ray spectrometry (EDX). Results: The results showed statistically significant alterations (P < 0.05) in the right vertical dimension, internal tie wing width (cervical), right and left depth of the slot (Kruskal–Wallis test). Multiple comparison using Mann–Whitney test showed that ceramic brackets underwent (P < 0.05) minimal alterations in the right vertical dimension, internal tie wing width (cervical), right and left depth of the slot (0.01 mm, −0.003 mm, 0.006 mm, −0.002 mm, respectively) when compared with the changes seen in SS and self-ligating brackets. SEM analysis revealed an increase in the surface roughness of ceramic with metal slot brackets and self-ligating bracket showed the least irregularity. The presence of calcium was noted on all evaluated brackets under EDX, but ceramic with metal slot brackets showed a significantly greater amount of enamel loss (P = 0.001). Conclusion: Ceramic brackets were found to be dimensionally stable when compared to SS and self-ligating. Self-ligating bracket showed minimal surface irregularity. Ceramic with metal slot brackets showed a greater amount of enamel loss following debonding. PMID:28566855

  18. The Effects of In-Office Reconditioning on the Slot Dimensions and Static Frictional Resistance of Stainless Steel Brackets.

    PubMed

    Iluru, Rohini; Nellore, Chaitanya; Karnati, Praveen Kumar Reddy; Thalapaneni, Ashok Kumar; Myla, Vijay Bhaskar; Ramyasree, Konda; Prasad, Mandava

    2016-01-01

    Orthodontists are commonly faced with the decision of what to do with loose brackets, and with inaccurately located brackets that need repositioning during treatment. One solution is to recycle the brackets. The potential effects of reconditioning a bracket are dependent upon many factors which may result in physical changes like alteration in slot tolerance, which may influence sliding mechanics by affecting frictional resistance. To study and compare the dimensional changes in the bracket slot width and depth in reconditioned brackets from unused brackets under scanning electronic microscope and to study and compare any consequent effects on the static frictional resistance of stainless steel brackets after reconditioning and in unused brackets. Dentarum manufactured 90 stainless steel central incisors edgewise brackets of size 0.22 X 0.030″ inch and 0° tip and 0°angulation were taken. 60 samples for measuring frictional resistance and 30 samples for measuring slot dimensions. Ortho organizers manufactured stainless steel arch wires 0.019 X 0.025″ straight lengths 60 in number were considered for measuring static frictional resistance. The mean slot width and depth of new brackets were 0.0251″ and 0.0471″, which exceeded the manufacturers reported nominal size of 0.022″ X 0.030″, by 0.003″ and 0.017″. The reconditioned brackets demonstrated a further increase in mean slot width and depth to 0.028″ and 0.0518″ that is by 0.0035″ and 0.0047″ which is statistically significant (p=0.001, 0.002). The mean static frictional forces of the reconditioned brackets was nearly similar to that of new brackets that is 0.3167N for reconditioned brackets and 0.2613 N for new brackets. Although the reconditioning process results in physical changes to bracket structure this does not appear to result in significant effect on ex-vivo static frictional resistance.

  19. A comparative assessment of torque generated by lingual and conventional brackets.

    PubMed

    Sifakakis, Iosif; Pandis, Nikolaos; Makou, Margarita; Eliades, Theodore; Katsaros, Christos; Bourauel, Christoph

    2013-06-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.

  20. Evaluating the Type of Light Transmittance in Mono Crystalline, Poly Crystalline and Sapphire Brackets- An Invitro Spectrofluorometer Study

    PubMed Central

    Kommi, Pradeep Babu; Kumar, M Senthil; Hanumanth; Venkatesan; Aniruddh; Arvinth; Kumar, Arani Nanda

    2016-01-01

    Introduction Most of the patients seek orthodontic treatment to improve the smile, which improves the facial profile by means of fixed appliances i.e., brackets and wires. The brackets are of different types like stainless steel and ceramic. Ceramic brackets were considered as aesthetic appliance which was divided into mono-crystalline, polycrystalline and sapphire brackets. The light transmittance might influence the degree of curing adhesive material in mono crystalline, polycrystalline and sapphire brackets. Aim The aim of the present study was to evaluate the translucency and intensity of three different aesthetic brackets (mono crystalline, poly crystalline and sapphire ceramic brackets) and to determine their influence on shear bond strength of the brackets. The adhesive remnant index was also measured after debonding of the brackets from the tooth surface. Materials and Methods Twenty six samples each of monocrystalline, polycrystalline and sapphire brackets (total 78 ceramic brackets) were used for the study. The bracket samples were subjected to optical fluorescence test using spectrofluorometer to measure the intensity of the brackets. Seventy eight extracted premolar teeth were procured and divided into 3 groups. The brackets were then bonded to the tooth using Transbond XT (3M Unitek) light cure composite material and cured with new light cure unit (Light Emitting Diode) of wood pecker company (400-450nm) for 30 seconds, and these samples were subjected to shear bond strength test with Instron Universal Testing Machine (UNITEK-94100) with a load range between 0 to 100 KN with a maximum cross head speed of 0.5mm/min. ARI (Adhesive Remnant Index) scores were evaluated according to Artun and Bergland scoring system using stereomicroscope at 20x magnification. Results The light absorption values obtained from spectrofluorometeric study were 3300000–3500000 cps for group 1 (monocrystalline ceramic brackets), 6000000–6500000 cps for Group 2 (polycrystalline ceramic brackets) and 2700000 –3000000 cps for Group 3 (sapphire ceramic brackets) i.e., Group 2 showed the highest light absorption and the least translucency followed by groups 1 and 3. Shear bond strength results were 2.4 mpa, 1.9 mpa and 3.6 mpa for groups 1,2 and 3 respectively. Superior shear bond strength was recorded in group 3 (sapphire ceramic brackets). ARI results showed that group 3 had increased bond between bracket adhesive interfaces when compared to the other 2 groups. Conclusion From this study, it has been concluded that sapphire ceramic brackets (Group 3) was superior in translucency and shear bond strength followed by monocrystalline and polycrystalline ceramic brackets. PMID:27656556

  1. Evaluating the Type of Light Transmittance in Mono Crystalline, Poly Crystalline and Sapphire Brackets- An Invitro Spectrofluorometer Study.

    PubMed

    Mohamed, Jauhar P; Kommi, Pradeep Babu; Kumar, M Senthil; Hanumanth; Venkatesan; Aniruddh; Arvinth; Kumar, Arani Nanda

    2016-08-01

    Most of the patients seek orthodontic treatment to improve the smile, which improves the facial profile by means of fixed appliances i.e., brackets and wires. The brackets are of different types like stainless steel and ceramic. Ceramic brackets were considered as aesthetic appliance which was divided into mono-crystalline, polycrystalline and sapphire brackets. The light transmittance might influence the degree of curing adhesive material in mono crystalline, polycrystalline and sapphire brackets. The aim of the present study was to evaluate the translucency and intensity of three different aesthetic brackets (mono crystalline, poly crystalline and sapphire ceramic brackets) and to determine their influence on shear bond strength of the brackets. The adhesive remnant index was also measured after debonding of the brackets from the tooth surface. Twenty six samples each of monocrystalline, polycrystalline and sapphire brackets (total 78 ceramic brackets) were used for the study. The bracket samples were subjected to optical fluorescence test using spectrofluorometer to measure the intensity of the brackets. Seventy eight extracted premolar teeth were procured and divided into 3 groups. The brackets were then bonded to the tooth using Transbond XT (3M Unitek) light cure composite material and cured with new light cure unit (Light Emitting Diode) of wood pecker company (400-450nm) for 30 seconds, and these samples were subjected to shear bond strength test with Instron Universal Testing Machine (UNITEK-94100) with a load range between 0 to 100 KN with a maximum cross head speed of 0.5mm/min. ARI (Adhesive Remnant Index) scores were evaluated according to Artun and Bergland scoring system using stereomicroscope at 20x magnification. The light absorption values obtained from spectrofluorometeric study were 3300000-3500000 cps for group 1 (monocrystalline ceramic brackets), 6000000-6500000 cps for Group 2 (polycrystalline ceramic brackets) and 2700000 -3000000 cps for Group 3 (sapphire ceramic brackets) i.e., Group 2 showed the highest light absorption and the least translucency followed by groups 1 and 3. Shear bond strength results were 2.4 mpa, 1.9 mpa and 3.6 mpa for groups 1,2 and 3 respectively. Superior shear bond strength was recorded in group 3 (sapphire ceramic brackets). ARI results showed that group 3 had increased bond between bracket adhesive interfaces when compared to the other 2 groups. From this study, it has been concluded that sapphire ceramic brackets (Group 3) was superior in translucency and shear bond strength followed by monocrystalline and polycrystalline ceramic brackets.

  2. In vitro assessment of photocatalytic titanium oxide surface modified stainless steel orthodontic brackets for antiadherent and antibacterial properties against Lactobacillus acidophilus.

    PubMed

    Shah, Alok Girish; Shetty, Pradeep Chandra; Ramachandra, C S; Bhat, N Sham; Laxmikanth, S M

    2011-11-01

    To assess the antiadherent and antibacterial properties of surface modified stainless steel orthodontic brackets with photocatalytic titanium oxide (TiO(2)) against Lactobacillus acidophilus. This study was done on 120 specimens of stainless steel preadjusted edgewise appliance (PEA) orthodontic brackets. The specimens were divided into four test groups. Each group consisted of 30 specimens. Groups containing uncoated brackets acted as a control group for their respective experimental group containing coated brackets. Surface modification of brackets was carried out by the radiofrequency (RF) magnetron sputtering method with photocatalytic TiO(2). Brackets then were subjected to microbiological tests for assessment of the antiadherent and antibacterial properties of photocatalytic TiO(2) coating against L acidophilus. Orthodontic brackets coated with photocatalytic TiO(2) showed an antiadherent effect against L acidophilus compared with uncoated brackets. The bacterial mass that was bound to the TiO(2)-coated brackets was less when compared with the uncoated brackets. Furthermore, TiO(2)-coated brackets had a bactericidal effect on L acidophilus, which causes dental caries. Surface modification of orthodontic brackets with photocatalytic TiO(2) can be used to prevent the accumulation of dental plaque and the development of dental caries during orthodontic treatment.

  3. Assessing near infrared optical properties of ceramic orthodontic brackets using cross-polarization optical coherence tomography.

    PubMed

    Isfeld, Darren M; Aparicio, Conrado; Jones, Robert S

    2014-04-01

    Secondary decay (caries) under ceramic orthodontic brackets remains a significant dental problem and near infrared cross-polarization optical coherence tomography (CP-OCT) has the potential to detect underlying demineralization. The purpose of this study was to determine the effect of crystalline structure and chemical composition of ceramic brackets on CP-OCT imaging. Four ceramic brackets types, which were divided into monocrystalline and polycrystalline, were examined using CP-OCT. The results of this study demonstrated that the crystallinity of the ceramic brackets affected the 1310 nm CP-OCT imaging with the greatest attenuation seen in polycrystalline alumina brackets. The alumina polycrystalline bracket materials had significantly higher attenuation and scattering than alumina monocrystalline brackets (p < 0.05, ANOVA, Bonferroni). Additionally, bracket base morphology and composition affected NIR light attenuation. There was considerable attenuation in bracket bases that contained additive zirconium spheres (∼30 µm) and this alteration was significantly greater than the jagged alumina crystallographic alterations found in the other bracket systems (p < 0.05, ANOVA, Bonferroni). Noninvasive, near infrared (NIR) cross-polarization optical coherence tomography (CP-OCT) has potential to effectively image through portions of ceramic brackets; however, further investigation into the optical effects of resin integration in the base portion of the brackets is warranted. © 2013 Wiley Periodicals, Inc.

  4. [Comparison of root resorption between self-ligating and conventional brackets using cone-beam CT].

    PubMed

    Liu, Yun; Guo, Hong-ming

    2016-04-01

    To analyze the differences of root resorption between passive self-ligating and conventional brackets, and to determine the relationship between passive self-ligating brackets and root resorption. Fifty patients were randomly divided into 2 groups using passive self-ligating brackets or conventional straight wire brackets (0.022 system), respectively. Cone-beam CT was taken before and after treatment. The amount of external apical root resorption of maxillary incisors was measured on CBCT images. Student's t test was performed to analyze the differences of root apical resorption between the 2 groups with SPSS17.0 software package. No significant difference(P> 0.05) in root resorption of maxillary incisors was found between passive self-ligating brackets and conventional brackets. Passive self-ligating brackets and conventional brackets can cause root resorption, but the difference was not significant. Passive self-ligating brackets do not induce more root resorption.

  5. Accounting for biotic spatial variability in fields: Case of resistance screening against sunflower Verticillium wilt

    PubMed Central

    Missonnier, Hélène; Jacques, Alban; Bang, JiSu; Daydé, Jean; Mirleau-Thebaud, Virginie

    2017-01-01

    In breeding for disease resistance, the magnitude of the genetic response is difficult to appreciate because of environmental stresses that interact with the plant genotype. We discuss herein the fundamental problems in breeding for disease resistance with the aim being to better understand the interactions between plant, pathogen, and spatial patterns. The goal of this study is to fine tune breeding decisions by incorporating spatial patterns of such biotic factors into the definition of disease-occurrence probability. We use a preexisting statistics method based on geostatistics for a descriptive analysis of biotic factors for trial quality control. The plant-population structure used for spatial-pattern analysis consists of two F1-hybrid cultivars, defined as symptomatic and asymptomatic controls with respect to the studied pathogen. The controls are inserted at specific locations to establish a grid arrangement over the field that include the F1-hybrid cultivars under evaluation. We characterize the spatial structure of the pathogen population and of the general plant environment—with undetermined but present abiotic constraints—not by using direct notation such as flower time or rainfall but by using plant behavior (i.e., leaf symptom severity, indirect notation). The analysis indicates areas with higher or lower risk of disease and reveals a correlation between the symptomatic control and the effective level of disease for sunflowers. This result suggests that the pathogen and/or abiotic components are major factors in determining the probability that a plant develops the disease, which could lead to a misinterpretation of plant resistance. PMID:28817567

  6. Accounting for biotic spatial variability in fields: Case of resistance screening against sunflower Verticillium wilt.

    PubMed

    Missonnier, Hélène; Jacques, Alban; Bang, JiSu; Daydé, Jean; Mirleau-Thebaud, Virginie

    2017-01-01

    In breeding for disease resistance, the magnitude of the genetic response is difficult to appreciate because of environmental stresses that interact with the plant genotype. We discuss herein the fundamental problems in breeding for disease resistance with the aim being to better understand the interactions between plant, pathogen, and spatial patterns. The goal of this study is to fine tune breeding decisions by incorporating spatial patterns of such biotic factors into the definition of disease-occurrence probability. We use a preexisting statistics method based on geostatistics for a descriptive analysis of biotic factors for trial quality control. The plant-population structure used for spatial-pattern analysis consists of two F1-hybrid cultivars, defined as symptomatic and asymptomatic controls with respect to the studied pathogen. The controls are inserted at specific locations to establish a grid arrangement over the field that include the F1-hybrid cultivars under evaluation. We characterize the spatial structure of the pathogen population and of the general plant environment-with undetermined but present abiotic constraints-not by using direct notation such as flower time or rainfall but by using plant behavior (i.e., leaf symptom severity, indirect notation). The analysis indicates areas with higher or lower risk of disease and reveals a correlation between the symptomatic control and the effective level of disease for sunflowers. This result suggests that the pathogen and/or abiotic components are major factors in determining the probability that a plant develops the disease, which could lead to a misinterpretation of plant resistance.

  7. 19 CFR 125.34 - Countersigning of documents and notation of bad order or discrepancy.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Countersigning of documents and notation of bad... and Receipt § 125.34 Countersigning of documents and notation of bad order or discrepancy. When a... and shall note thereon any bad order or discrepancy. When available, the importing carrier's tally...

  8. From Depiction to Notation: How Children Use Symbols to Represent Objects and Events

    ERIC Educational Resources Information Center

    Eskritt, Michelle; Olson, David

    2012-01-01

    The purpose of the present study was to explore children's understanding of external symbols by examining the relationship between children's production and comprehension of graphic notations and verbal messages. Fifty-six children between the ages of 5 and 7 years were asked to produce both notations and a spoken message relaying to their…

  9. Teaching Movable "Du": Guidelines for Developing Enrhythmic Reading Skills

    ERIC Educational Resources Information Center

    Dalby, Bruce

    2015-01-01

    Reading music notation with fluency is a complex skill requiring well-founded instruction by the music teacher and diligent practice on the part of the learner. The task is complicated by the fact that there are multiple ways to notate a given rhythm. Beginning music students typically have their first encounter with enrhythmic notation when they…

  10. A Proposal of a Color Music Notation System on a Single Melody for Music Beginners

    ERIC Educational Resources Information Center

    Kuo, Yi-Ting; Chuang, Ming-Chuen

    2013-01-01

    Music teachers often encounter obstructions in teaching beginners in music reading. Conventional notational symbols require beginners to spend significant amount of time in memorizing, which discourages learning at early stage. This article proposes a newly-developed color music notation system that may improve the recognition of the staff and the…

  11. A quantitative AFM analysis of nano-scale surface roughness in various orthodontic brackets.

    PubMed

    Lee, Gi-Ja; Park, Ki-Ho; Park, Young-Guk; Park, Hun-Kuk

    2010-10-01

    In orthodontics, the surface roughnesses of orthodontic archwire and brackets affect the effectiveness of arch-guided tooth movement, corrosion behavior, and the aesthetics of orthodontic components. Atomic force microscopy (AFM) measurements were used to provide quantitative information on the surface roughness of the orthodontic material. In this study, the changes in surface roughness of various orthodontic bracket slots before and after sliding movement of archwire in vitro and in vivo were observed through the utilization of AFM. Firstly, we characterized the surface of four types of brackets slots as follows: conventional stainless steel (Succes), conventional ceramic (Perfect), self-ligating stainless steel (Damon) and self-ligating ceramic (Clippy-C) brackets. Succes) and Damon brackets showed relatively smooth surfaces, while Perfect had the roughest surface among the four types of brackets used. Secondly, after in vitro sliding test with beta titanium wire in two conventional brackets (Succes and Perfect), there were significant increases in only stainless steel bracket, Succes. Thirdly, after clinical orthodontic treatment for a maximum of 2 years, the self-ligating stainless steel bracket, Damon, showed a significant increase in surface roughness. But self-ligating ceramic brackets, Clippy-C, represented less significant changes in roughness parameters than self-ligating stainless steel ones. Based on the results of the AFM measurements, it is suggested that the self-ligating ceramic bracket has great possibility to exhibit less friction and better biocompatibility than the other tested brackets. This implies that these bracket slots will aid in the effectiveness of arch-guided tooth movement.

  12. Design of an Orthodontic Torque Simulator for Measurement of Bracket Deformation

    NASA Astrophysics Data System (ADS)

    Melenka, G. W.; Nobes, D. S.; Major, P. W.; Carey, J. P.

    2013-12-01

    The design and testing of an orthodontic torque simulator that reproduces the effect of archwire rotation on orthodontic brackets is described. This unique device is capable of simultaneously measuring the deformation and loads applied to an orthodontic bracket due to archwire rotation. Archwire rotation is used by orthodontists to correct the inclination of teeth within the mouth. This orthodontic torque simulator will provide knowledge of the deformation and loads applied to orthodontic bracket that will aide clinicians by describing the effect of archwire rotation on brackets. This will also impact that design on new archwirebracket systems by providing an assessment of performance. Deformation of the orthodontic bracket tie wings is measured using a digital image correlation process to measure elastic and plastic deformation. The magnitude of force and moments applied to the bracket though the archwire is also measured using a six-axis load cell. Initial tests have been performed on two orthodontic brackets of varying geometry to demonstrate the measurement capability of the orthodontic torque simulator. The demonstration experiment shows that a Damon Q bracket had a final plastic deformation after a single loading of 0.022 mm while the Speed bracket deformed 0.071 mm. This indicates that the Speed bracket plastically deforms 3.2 times more than the Damon Q bracket for similar magnitude of applied moment. The demonstration experiment demonstrates that bracket geometry affect the deformation of orthodontic brackets and this difference can be detected using the orthodontic torque simulator.

  13. Histologic investigation of the human pulp after thermodebonding of metal and ceramic brackets.

    PubMed

    Jost-Brinkmann, P G; Stein, H; Miethke, R R; Nakata, M

    1992-11-01

    Twenty-five human permanent teeth scheduled for extraction for orthodontic reasons were used to study the effect of thermodebonding on the pulp tissue. One week before brackets were removed the teeth were bonded with either metal or ceramic brackets, with two alternative adhesives. For debonding, three different techniques were used: (1) debonding of ceramic brackets warmed up indirectly by resistance heating of a metallic bow applied to the bracket slot, (2) debonding of metal brackets warmed up directly by inductive heating of the bracket itself, and (3) debonding of ceramic brackets warmed up indirectly by inductive heating of metallic plier tips, applied to the mesial and distal bracket surfaces. Teeth with metal brackets removed without heat by squeezing the wings together served as a control group. The teeth were extracted 24 hours after debonding and subjected to a light microscopic study after histologic preparation and staining. In addition, the location of adhesive remnants was evaluated. While the thermodebonding of metal brackets worked properly and without any obvious pulp damage, there were problems related to the thermodebonding of ceramic brackets: (1) if more than one heating cycle was necessary, several teeth showed localized damage of the pulp with slight infiltration of inflammatory cells, (2) bracket fractures occurred frequently, and enamel damage could be shown, and (3) often with Transbond (Unitek/3M, Monrovia, Calif.) as the adhesive, more than one heating cycle was necessary for bracket removal, and thus patients complained about pain.

  14. Microbial profile on metallic and ceramic bracket materials.

    PubMed

    Anhoury, Patrick; Nathanson, Dan; Hughes, Christopher V; Socransky, Sigmund; Feres, Magda; Chou, Laisheng Lee

    2002-08-01

    The placement of orthodontic appliances creates a favorable environment for the accumulation of a microbiota and food residues, which, in time, may cause caries or exacerbate any pre-existing periodontal disease. The purpose of the present study was to compare the total bacterial counts present on metallic and ceramic orthodontic brackets in order to clarify which bracket type has a higher plaque retaining capacity and to determine the levels of Streptococcus mutans and Lactobacillus spp on both types of brackets. Thirty-two metallic brackets and 24 ceramic brackets were collected from orthodontic patients at the day of debonding. Two brackets were collected from each patient; one from a maxillary central incisor and another from a maxillary second premolar. Sixteen patients who used metallic brackets and 12 patients who used ceramic brackets were sampled. Bacterial populations were studied using "checkerboard" DNA-DNA hybridization, which uses DNA probes to identify species in complex microbial samples. The significance of differences between groups was determined using the Mann-Whitney U-test. Results showed no significant differences between metallic and ceramic brackets with respect to the caries-inducing S mutans and L acidophilus spp counts. Mean counts of 8 of 35 additional species differed significantly between metallic and ceramic brackets with no obvious pattern favoring one bracket type over the other. This study showed higher mean counts of Treponema denticola, Actinobacillus actinomycetemcomitans, Fusobacterium nucleatum ss vincentii, Streptococcus anginosus, and Eubacterium nodatum on metallic brackets while higher counts of Eikenella corrodens, Campylobacter showae, and Selenomonas noxia were found on ceramic brackets.

  15. Evaluation of the Friction of Self-Ligating and Conventional Bracket Systems

    PubMed Central

    Tecco, Simona; Di Iorio, Donato; Nucera, Riccardo; Di Bisceglie, Beatrice; Cordasco, Giancarlo; Festa, Felice

    2011-01-01

    Objectives: This in vitro study evaluated the friction (F) generated by aligned stainless steel (SS) conventional brackets, self-ligating Damon MX© brackets (SDS Ormco, Glendora, California, USA), Time3© brackets (American Orthodontics, Sheboygan, Wisconsin, USA), Vision LP© brackets (American Orthodontics), and low-friction Slide© ligatures (Leone, Firenze, Italy) coupled with various SS, nickel-titanium (NiTi), and beta-titanium (TMA) archwires. Methods: All brackets had a 0.022-inch slot, and the orthodontic archwires were 0.014-inch, 0.016-inch, 0.014×0.025-inch, 0.018×0.025-inch, and 0.019×0.025-inch NiTi; 0.017×0.025-inch TMA; and 0.019×0.025-inch SS. Each bracket-archwire combination was tested 10 times. In the test, 10 brackets of the same group were mounted in alignment on a metal bar. The archwires moved through all the 10 brackets at a crosshead speed of 0.5 mm/min (each run lasted approximately 5 min). The differences among 5 groups of brackets were analyzed through the Kruskal-Wallis test, and a Mann-Whitney test was calculated as post hoc analysis. The P value was set at 0.05. Results: Coupled with 0.014-inch NiTi and 0.016-inch NiTi, Victory Series© brackets generated the greatest F, while Damon MX© and Vision LP© brackets generated the lowest (P<.05); no significant differences were observed between Time3© brackets and Slide© ligatures. Coupled with all the rectangular archwires, Victory Series© brackets, Slide© ligatures, and Vision LP© self-ligating brackets generated significantly lower F than did Time3© and Damon MX© self-ligating brackets (P<.05). Conclusions: These findings suggest that self-ligating brackets are a family of brackets that, in vitro, can generate different levels of F when coupled with thin or thick, rectangular, or round archwires. Clinical conclusions based on our results are not possible due to the limitations of the experimental conditions. PMID:21769273

  16. Adhesion of periodontal pathogens to self-ligating orthodontic brackets: An in-vivo prospective study.

    PubMed

    Jung, Woo-Sun; Kim, Kyungsun; Cho, Soha; Ahn, Sug-Joon

    2016-09-01

    Our aims were to analyze adhesion of periodontopathogens to self-ligating brackets (Clarity-SL [CSL], Clippy-C [CC] and Damon Q [DQ]) and to identify the relationships between bacterial adhesion and oral hygiene indexes. Central incisor brackets from the maxilla and mandible were collected from 60 patients at debonding after the plaque and gingival indexes were measured. Adhesions of Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Fusobacterium nucleatum (Fn), and Tannerella forsythia (Tf) were quantitatively determined using real-time polymerase chain reactions. Factorial analysis of variance was used to analyze bacterial adhesion in relation to bracket type and jaw position. Correlation coefficients were calculated to determine the relationships between bacterial adhesion and the oral hygiene indexes. Total bacteria showed greater adhesion to CSL than to DQ brackets, whereas Aa, Pg, and Pi adhered more to DQ than to CSL brackets. CC brackets showed an intermediate adhesion pattern between CSL and DQ brackets, but it did not differ significantly from either bracket type. Adhesion of Fn and Tf did not differ significantly among the 3 brackets. Most bacteria were detected in greater quantities in the mandibular than in the maxillary brackets. The plaque and gingival indexes were not strongly correlated with bacterial adhesion to the brackets. Because Aa, Pg, and Pi adhered more to the DQ brackets in the mandibular area, orthodontic patients with periodontal problems should be carefully monitored in the mandibular incisors where the distance between the bracket and the gingiva is small, especially when DQ brackets are used. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study.

    PubMed

    Karim Soltani, Mohammad; Golfeshan, Farzaneh; Alizadeh, Yoones; Mehrzad, Jabraiel

    2015-03-01

    Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. The samples included 4 types of brackets; metallic and clear Damon brackets and metallic and clear conventional brackets (10 brackets in each group). In this study, stainless steel wires sized 0.019×0.025 were employed and the operator's saliva was used to simulate the conditions of oral cavity. The tidy-modified design was used for simulation of sliding movement. The resistance to sliding and static frictional forces was measured by employing Testometric machine and load cell. The mean (±SD) of resistance to sliding was 194.88 (±26.65) and 226.62 (±39.9) g in the esthetic and metallic Damon brackets, while these values were 187.81(±27.84) and 191.17(±66.68) g for the clear and metallic conventional brackets, respectively. Static frictional forces were 206.4(±42.45) and 210.38(±15.89) g in the esthetic and metallic Damon brackets and 220.63(±49.29) and 215.13(±62.38) g in the clear and metallic conventional brackets. According to two-way ANOVA, no significant difference was observed between the two bracket materials (clear and metal) and the two types of bracket (self-ligating versus conventional) regarding resistance to sliding (p= 0.17 and p= 0.23, respectively) and static frictional forces (p= 0.55 and p= 0.96, respectively). Neither the type of bracket materials nor their type of ligation made difference in resistance to sliding and static friction.

  18. Comparison of frictional resistance among conventional, active and passive selfligating brackets with different combinations of arch wires: a finite elements study.

    PubMed

    Gómez, Sandra L; Montoya, Yesid; Garcia, Nora L; Virgen, Ana L; Botero, Javier E

    2016-09-01

    The aim of this study was to compare frictional resistance among conventional, passive and active selfligating brackets using Finite Elements Analysis (FEA). Seventynine (79) slide tests were performed by combining an upper first bicuspid conventional bracket, 0.018" stainless steel wires and 0.010" ligature by means of an INSTRON 3345 load system to obtain average maximum static frictional resistance (MSFR). This value was compared to the FR (frictional resistance) obtained by simulation of a slide of the same combination by FEA following conventional bracket modeling by means of Computer Aided Design (CAD). Once the FEA was validated, bracket CADs were designed (upper right first bicuspid conventional, active and passive selfligating bracket) and bracket properties calculated. MSFR was compared among conventional, active and passive selfligating brackets with different alloys and archwire cross sections such as 0.018", 0.019" x 0.025"and 0.020" x 0.020". Passive selfligating brackets had the lowest MSFR, followed by conventional brackets and active selfligating brackets. In conventional brackets, a 0.018" archwire produced a linear pattern of stress with maximum concentration at the center. Conversely, stress in 0.020 x 0.020" and 0.019 x 0.025" archwires was distributed across the width of the slot. The highest normal forces were 1.53 N for the 0.018" archwire, 4.85 N for the 0.020 x 0.020" archwire and 8.18 N for the 0.019 x 0.025" archwire. Passive selfligating brackets presented less frictional resistance than conventional and active selfligating brackets. Regardless of bracket type, greater contact area between the slot and the archwire and the spring clip increased frictional resistance. Sociedad Argentina de Pediatría.

  19. An in vitro study into the efficacy of complex tooth alignment with conventional and self-ligating brackets.

    PubMed

    Montasser, M A; Keilig, L; Bourauel, C

    2015-02-01

    To evaluate the efficacy of tooth alignment achieved by various small cross-section archwire/bracket combinations using the orthodontic measurement and simulation system. The study comprised three types of orthodontic brackets 1) conventional ligating (Victory Series and Mini-Taurus), 2) self-ligating (SmartClip a passive self-ligating bracket and Time3 an active self-ligating bracket), and 3) a conventional low-friction bracket (Synergy). All brackets had a nominal 0.022″ slot size. Brackets were combined with 1) 0.012″ stainless steel, 2) 0.012″ Orthonol, 3) 0.012″ Thermalloy, and 4) 0.0155″ coaxial archwires. Archwires were tied to the conventional brackets with stainless steel ligatures and elastomeric rings. The malocclusion simulated represented a central upper incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). The inciso-gingival correction achieved by the different archwire/bracket combinations ranged from 15 to 95%, while the labio-lingual correction ranged from 10 to 95%. The smallest correction was achieved by coaxial, Orthonol, and thermally archwires when ligated with the elastomeric rings to conventional brackets. Stainless steel archwires achieved from 65 to 90% of inciso-gingival correction and from 60 to 90% of labio-lingual correction. The resultant tooth alignment was the product of interaction between the archwire type, bracket type, and bracket design including ligature type. Small cross-sectional archwires might produce up to 95% correction if combined properly with the bracket system. Elastomeric rings when used with conventional brackets limit the efficacy of malalignment correction. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Frictional and mechanical properties of diamond-like carbon-coated orthodontic brackets.

    PubMed

    Muguruma, Takeshi; Iijima, Masahiro; Brantley, William A; Nakagaki, Susumu; Endo, Kazuhiko; Mizoguchi, Itaru

    2013-04-01

    This study investigated the effects of a diamond-like carbon (DLC) coating on frictional and mechanical properties of orthodontic brackets. DLC films were deposited on stainless steel brackets using the plasma-based ion implantation/deposition (PBIID) method under two different atmospheric conditions. As-received metal brackets served as the control. Two sizes of stainless steel archwires, 0.018 inch diameter and 0.017 × 0.025 inch cross-section dimensions, were used for measuring static and kinetic friction by drawing the archwires through the bracket slots, using a mechanical testing machine (n = 10). The DLC-coated brackets were observed with a scanning electron microscope (SEM). Values of hardness and elastic modulus were obtained by nanoindentation testing (n = 10). Friction forces were compared by one-way analysis of variance and the Scheffé test. The hardness and elastic modulus of the brackets were compared using Kruskal-Wallis and Mann-Whitney U-tests. SEM photomicrographs showed DLC layers on the bracket surfaces with thickness of approximately 5-7 μm. DLC-coated brackets deposited under condition 2 showed significantly less static frictional force for the stainless steel wire with 0.017 × 0.025 inch cross-section dimensions than as-received brackets and DLC-coated brackets deposited under condition 1, although both DLC-coated brackets showed significantly less kinetic frictional force than as-received brackets. The hardness of the DLC layers was much higher than that of the as-received bracket surfaces. In conclusion, the surfaces of metal brackets can be successfully modified by the PBIID method to create a DLC layer, and the DLC-coating process significantly reduces frictional forces.

  1. Orthodontic bracket slot dimensions as measured from entire bracket series.

    PubMed

    Brown, Paul; Wagner, Warren; Choi, Hyden

    2015-07-01

    To measure the slot dimensions of an entire series of metal orthodontic brackets. Ten bracket series approximating five complete sets of brackets each were imaged and measured. Descriptive statistics were generated. Slot dimension varied significantly from series to series as well as within the series themselves. About one-third of the brackets would not accommodate a full-size wire, and 15% to 20% are 0.001 inches or larger than the nominal advertised size. The clinician is unlikely to have on hand complete sets (upper and lower 5-5) of ideal brackets and should both expect and be able to be accommodate tooth movement through wire bending in three planes of space to overcome any bracket deficiencies.

  2. Investigating and improving student understanding of the expectation values of observables in quantum mechanics

    NASA Astrophysics Data System (ADS)

    Marshman, Emily; Singh, Chandralekha

    2017-07-01

    The expectation value of an observable is an important concept in quantum mechanics since measurement outcomes are, in general, probabilistic and we only have information about the probability distribution of measurement outcomes in a given quantum state of a system. However, we find that upper-level undergraduate and PhD students in physics have both conceptual and procedural difficulties when determining the expectation value of a physical observable in a given quantum state in terms of the eigenstates and eigenvalues of the corresponding operator, especially when using Dirac notation. Here we first describe the difficulties that these students have with determining the expectation value of an observable in Dirac notation. We then discuss how the difficulties found via student responses to written surveys and individual interviews were used as a guide in the development of a quantum interactive learning tutorial (QuILT) to help students develop a good grasp of the expectation value. The QuILT strives to help students integrate conceptual understanding and procedural skills to develop a coherent understanding of the expectation value. We discuss the effectiveness of the QuILT in helping students learn this concept from in-class evaluations.

  3. Structural support bracket for gas flow path

    DOEpatents

    None

    2016-08-02

    A structural support system is provided in a can annular gas turbine engine having an arrangement including a plurality of integrated exit pieces (IEPs) forming an annular chamber for delivering gases from a plurality of combustors to a first row of turbine blades. A bracket structure is connected between an IEP and an inner support structure on the engine. The bracket structure includes an axial bracket member attached to an IEP and extending axially in a forward direction. A transverse bracket member has an end attached to the inner support structure and extends circumferentially to a connection with a forward end of the axial bracket member. The transverse bracket member provides a fixed radial position for the forward end of the axial bracket member and is flexible in the axial direction to permit axial movement of the axial bracket member.

  4. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    NASA Astrophysics Data System (ADS)

    Han, Xianglong; Liu, Xiaolin; Bai, Ding; Meng, Yao; Huang, Lan

    2008-11-01

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure.

  5. RNApdbee--a webserver to derive secondary structures from pdb files of knotted and unknotted RNAs.

    PubMed

    Antczak, Maciej; Zok, Tomasz; Popenda, Mariusz; Lukasiak, Piotr; Adamiak, Ryszard W; Blazewicz, Jacek; Szachniuk, Marta

    2014-07-01

    In RNA structural biology and bioinformatics an access to correct RNA secondary structure and its proper representation is of crucial importance. This is true especially in the field of secondary and 3D RNA structure prediction. Here, we introduce RNApdbee-a new tool that allows to extract RNA secondary structure from the pdb file, and presents it in both textual and graphical form. RNApdbee supports processing of knotted and unknotted structures of large RNAs, also within protein complexes. The method works not only for first but also for high order pseudoknots, and gives an information about canonical and non-canonical base pairs. A combination of these features is unique among existing applications for RNA structure analysis. Additionally, a function of converting between the text notations, i.e. BPSEQ, CT and extended dot-bracket, is provided. In order to facilitate a more comprehensive study, the webserver integrates the functionality of RNAView, MC-Annotate and 3DNA/DSSR, being the most common tools used for automated identification and classification of RNA base pairs. RNApdbee is implemented as a publicly available webserver with an intuitive interface and can be freely accessed at http://rnapdbee.cs.put.poznan.pl/. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. Comparative Analysis of Bracket Slot Dimensions Evaluating Different Manufacturing Techniques

    DTIC Science & Technology

    2015-04-24

    Bracket 1 (Avex Suite, Opal ) .......................................... 39 Appendix B: Raw data—Bracket 2 (Victory Series, 3M...32 viii LIST OF FIGURES Figure 1: Bracket 1 (Avex Suite, Opal ) ................................................................ 10...15 Figure 7: Example of points selected using Bracket 1 (Avex Suite, Opal

  7. Three-dimensional deformation of orthodontic brackets

    PubMed Central

    Melenka, Garrett W; Nobes, David S; Major, Paul W

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire–bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design. PMID:23762201

  8. Three-dimensional deformation of orthodontic brackets.

    PubMed

    Melenka, Garrett W; Nobes, David S; Major, Paul W; Carey, Jason P

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire-bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design.

  9. Comparison of Movement Notation (Laban) and Traditional Methodological Learning Success in Teaching Folk Dances

    ERIC Educational Resources Information Center

    Elyagutu, Dilek Cantekin; Hazar, Muhsin

    2017-01-01

    In this research, Movement Notation (Laban) and Traditional Method in Folk dance Teaching were compared in terms of learning success. Movement notation group (n = 14) and Traditional group (n = 14) consisting of students from the S.U. State Conservatory Turkish Folk Dance Department were formed. During the 14-week-long study, the symbols of the…

  10. A Symbolic Dance: The Interplay between Movement, Notation, and Mathematics on a Journey toward Solving Equations

    ERIC Educational Resources Information Center

    Hewitt, Dave

    2014-01-01

    This article analyzes the use of the software Grid Algebra with a mixed ability class of 21 nine-to-ten-year-old students who worked with complex formal notation involving all four arithmetic operations. Unlike many other models to support learning, Grid Algebra has formal notation ever present and allows students to "look through" that…

  11. Is That a Y or a...? Representation of Hand Configuration Data in Different Notation Systems for Child Acquisition of ASL

    ERIC Educational Resources Information Center

    Hochgesang, Julie A.

    2013-01-01

    In my dissertation, I examine four notation systems used to represent hand configurations in child acquisition of signed languages. Linguists have long recognized the descriptive limitations of Stokoe notation, currently the most commonly used system for phonetic or phonological transcription, but continue using it because of its widespread…

  12. Writing about Music: The Selection and Arrangement of Notation in Jazz Students' Written Texts

    ERIC Educational Resources Information Center

    Martin, Jodie L.

    2018-01-01

    Music notation is intrinsic in the composition and performance of Western art music and also in its analysis and research. The process of writing about music remains underexplored, in particular how excerpts of music notation are selected and arranged in a written text, and how that text describes and contextualises the excerpts. This article…

  13. The British Sign Language Variant of Stokoe Notation: Report on a Type-Design Project.

    ERIC Educational Resources Information Center

    Thoutenhoofd, Ernst

    2003-01-01

    Explores the outcome of a publicly-funded research project titled "Redesign of the British Sign Language (BSL) Notation System with a New Font for Use in ICT." The aim of the project was to redesign the British Sign Language variant of Stokoe notation for practical use in information technology systems and software, such as lexical…

  14. Community of Interest Engagement Process Plan

    DTIC Science & Technology

    2012-02-09

    and input from Subject Matter Experts (SMEs), as shown in the far left of Figure 2. The team may prepare a Business Process Model Notation ( BPMN ) 22...22 Business Process Modeling Notation ( BPMN ) is a method of illustrating business processes in the form of a...Community of Interest Engagement Plan Joint Planning and Development Office 21 10. Acronyms BPMN Business Process Modeling Notation COI

  15. The Cooperate Assistive Teamwork Environment for Software Description Languages.

    PubMed

    Groenda, Henning; Seifermann, Stephan; Müller, Karin; Jaworek, Gerhard

    2015-01-01

    Versatile description languages such as the Unified Modeling Language (UML) are commonly used in software engineering across different application domains in theory and practice. They often use graphical notations and leverage visual memory for expressing complex relations. Those notations are hard to access for people with visual impairment and impede their smooth inclusion in an engineering team. Existing approaches provide textual notations but require manual synchronization between the notations. This paper presents requirements for an accessible and language-aware team work environment as well as our plan for the assistive implementation of Cooperate. An industrial software engineering team consisting of people with and without visual impairment will evaluate the implementation.

  16. BPMN, Toolsets, and Methodology: A Case Study of Business Process Management in Higher Education

    NASA Astrophysics Data System (ADS)

    Barn, Balbir S.; Oussena, Samia

    This chapter describes ongoing action research which is exploring the use of BPMN and a specific toolset - Intalio Designer to capture the “as is” essential process model of part of an overarching large business process within higher education. The chapter contends that understanding the efficacy of the BPMN notation and the notational elements to use is not enough. Instead, the effectiveness of a notation is determined by the notation, the toolset that is being used, and methodological consideration. The chapter presents some of the challenges that are faced in attempting to develop computation independent models in BPMN using toolsets such as Intalio Designer™.

  17. Application fields for the new Object Management Group (OMG) Standards Case Management Model and Notation (CMMN) and Decision Management Notation (DMN) in the perioperative field.

    PubMed

    Wiemuth, M; Junger, D; Leitritz, M A; Neumann, J; Neumuth, T; Burgert, O

    2017-08-01

    Medical processes can be modeled using different methods and notations. Currently used modeling systems like Business Process Model and Notation (BPMN) are not capable of describing the highly flexible and variable medical processes in sufficient detail. We combined two modeling systems, Business Process Management (BPM) and Adaptive Case Management (ACM), to be able to model non-deterministic medical processes. We used the new Standards Case Management Model and Notation (CMMN) and Decision Management Notation (DMN). First, we explain how CMMN, DMN and BPMN could be used to model non-deterministic medical processes. We applied this methodology to model 79 cataract operations provided by University Hospital Leipzig, Germany, and four cataract operations provided by University Eye Hospital Tuebingen, Germany. Our model consists of 85 tasks and about 20 decisions in BPMN. We were able to expand the system with more complex situations that might appear during an intervention. An effective modeling of the cataract intervention is possible using the combination of BPM and ACM. The combination gives the possibility to depict complex processes with complex decisions. This combination allows a significant advantage for modeling perioperative processes.

  18. Analysis of Shear Bond Strength and Morphology of Er:YAG Laser-Recycled Ceramic Orthodontic Brackets.

    PubMed

    Han, Ruo-qiao; Yang, Kai; Ji, Ling-fei; Ling, Chen

    2016-01-01

    The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p < 0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods.

  19. A proposed physical analog for a quantum probability amplitude

    NASA Astrophysics Data System (ADS)

    Boyd, Jeffrey

    What is the physical analog of a probability amplitude? All quantum mathematics, including quantum information, is built on amplitudes. Every other science uses probabilities; QM alone uses their square root. Why? This question has been asked for a century, but no one previously has proposed an answer. We will present cylindrical helices moving toward a particle source, which particles follow backwards. Consider Feynman's book QED. He speaks of amplitudes moving through space like the hand of a spinning clock. His hand is a complex vector. It traces a cylindrical helix in Cartesian space. The Theory of Elementary Waves changes direction so Feynman's clock faces move toward the particle source. Particles follow amplitudes (quantum waves) backwards. This contradicts wave particle duality. We will present empirical evidence that wave particle duality is wrong about the direction of particles versus waves. This involves a paradigm shift; which are always controversial. We believe that our model is the ONLY proposal ever made for the physical foundations of probability amplitudes. We will show that our ``probability amplitudes'' in physical nature form a Hilbert vector space with adjoints, an inner product and support both linear algebra and Dirac notation.

  20. Effects of green tea on the shear bond strength of orthodontic brackets after in-office vital bleaching.

    PubMed

    Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Lopes, Murilo Baena; Oltramari-Navarro, Paula Vanessa; Fernandes, Thais Maria; Schwertner, Renata de Castro Alves; Ursi, Wagner José Silva

    2016-01-01

    The application of bleaching agents before placement of resin-bonded fixed appliances significantly, but temporarily, reduces bond strength to tooth structure. Antioxidants have been studied as a means to remove residual oxygen that compromises bonding to bleached enamel. This in vitro study evaluated whether green tea (GT) could restore the shear bond strength between bonded orthodontic brackets and bleached enamel. Six experimental groups were compared: group 1, no bleaching plus bracket bonding (positive control); group 2, bleaching with 35% hydrogen peroxide (HP) plus bracket bonding (negative control); group 3, 35% HP plus 10% sodium ascorbate (SA) plus bracket bonding; group 4, 35% HP plus 10% GT plus bracket bonding; group 5, no bleaching plus 10% SA plus bracket bonding; group 6, no bleaching plus 10% GT plus bracket bonding. Results suggested that GT, like SA, may be beneficial for bracket bonding immediately after bleaching.

  1. Laser debonding of ceramic orthodontic brackets: a theoretical approach

    NASA Astrophysics Data System (ADS)

    Kearney, Kristine L.; Marangoni, Roy D.; Rickabaugh, Jeff L.

    1992-06-01

    Ceramic brackets are an esthetic substitute for conventional stainless steel brackets in orthodontic patients. However, ceramic brackets are more brittle and have higher bond strengths which can lead to bracket breakage and enamel damage during debonding. It has been demonstrated that various lasers can facilitate ceramic bracket removal. One mechanism with the laser is through the softening of the bracket adhesive. The high energy density from the laser on the bracket and adhesive can have a resultant deleterious thermal effect on the pulp of the tooth which may lead to pulpal death. A theoretical computer model of bracket, adhesive, enamel and dentin has been generated for predicting heat flow through this system. Heat fluxes at varying intensities and modes have been input into the program and the resultant temperatures at various points or nodes were determined. Further pursuit should lead to optimum parameters for laser debonding which would have minimal effects on the pulp.

  2. Influence of Preadjusted Bracket Shape and Positioning Reference on Angulation of Upper Central Incisor.

    PubMed

    Topolski, Francielle; de O Accorsi, Mauricio A; Trevisi, Hugo J; Cuoghi, Osmar A; Moresca, Ricardo

    2016-10-01

    To verify the influence of different bracket shapes and placement references according to Andrews and MBT systems on the expression of angulation in upper central incisors (UCI). Bracket positioning and mesiodistal dental movement simulations were performed and the angulations produced in the dental crown were evaluated, based on computed tomography scan images of 30 UCI and AutoCAD software analysis. Rectangular (Andrews) and rhomboid (MBT) brackets were placed according to the references recommended by Andrews and MBT systems - long axis of the clinical crown (LACC) and incisal edge (IE) respectively. Data showed that the use of LACC as reference for bracket positioning produced 5° and 4° UCI angulations in Andrews and MBT brackets respectively. The use of IE produced a 1.2° mean angulation in UCI for both brackets. When the LACC was used as reference for bracket positioning, the UCI crown angulation corresponded to the angulation built into the brackets, regardless of shape, while the use of IE resulted in natural crown angulation, regardless of bracket shape. This research contributes to guide the orthodontist in relation to the different treatment techniques based on the use of preadjusted brackets.

  3. Slot deformation of various stainless steel bracket due to the torque force of the beta-titanium wire

    NASA Astrophysics Data System (ADS)

    Huda, M. M.; Siregar, E.; Ismah, N.

    2017-08-01

    Stainless steel bracket slot deformation ffects the force applied to teeth and it can impede tooth movement and prolong orthodontic treatment time. The aim of this study is to determine the slot deformation due to torque of a 0.021 × 0.025 inch Beta Titanium wire with a torsional angle of 30° and 45° for five different bracket brands: y, 3M, Biom, Versadent, Ormco, and Shinye. The research also aims to compare the deformation and amount of torque among all five bracket brands at torsional angles of 30° and 45°. Fifty stainless steel edgewise brackets from the five bracket group brands (n=10) were attached to acrylic plates. The bracket slot measurements were carried out in two stages. In the first stage, the, deformation was measured by calculating the average bracket slot height using a stereoscopy microscope before and after application of torque. In the second stage, the torque was measured using a torque measurement apparatus. The statistical analysis shows that slot deformations were found on all five bracket brands with a clinical permanent deformation on the Biom (2.79 μm) and Shinye (2.29 μm) brackets. The most torque was observed on the 3M bracket, followed by the Ormco, Versadent, Shinye, and Biom brackets. When the brands were compared, a correlation between bracket slot deformation and the amount of torque was found, but the correlation was not statistically significant for the 3M and Ormco brackets and the Biom and Shinye brackets. There is a difference in the amount of torque between the five brands with a torsional angle of 30° (except the 3M and Ormco brackets) and those with a torsional angle of 45°. The composition of the metal and the manufacturing process are the factors that influence the occurrence of bracket slot deformation and the amount of torque. A manufacturing process using metal injection molding (MIM) and metal compositions of AISI 303 and 17-4 PH stainless steel reduce the risk of deformation.

  4. 49 CFR 180.403 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... to appurtenances, such as fender attachments, lighting brackets, ladder brackets; and (2) Replacement..., lighting brackets, ladder brackets; and (2) Replacement of components such as valves, vents, and fittings...

  5. A Comparative Evaluation of Adherence of Microorganism to Different Types of Brackets: A Scanning Electron Microscopic Study.

    PubMed

    Shashidhar, E P; Sahitya, M; Sunil, T; Murthy, Anup R; Rani, M S

    2015-09-01

    The purpose of this study was to evaluate and compare the adherence of microorganism to different types of brackets using the scanning electron microscope (SEM). A double-blinded study was undertaken to evaluate and adherence of microorganisms to different types of brackets using SEM. At random, 12 patients reporting for treatment to the department of Orthodontics VS Dental College and Hospital were selected. Four types of brackets were included in the present study stainless steel, titanium, composite, and ceramic. Brackets were bonded to teeth of the patient on all the four quadrants. The teeth included for bonding were lateral incisor, canine, first premolar, and second premolar. The brackets were left for 72 h. After 72 h brackets were debonded, and they were evaluated by SEM for adherence of microorganism in the slot and tie wings surface. The SEM images were graded, and the adherence of microorganism to the brackets in the surfaces and the four different quadrants were recorded. There is a significant difference in adherence of microorganisms to the various types of brackets (P < 0.001) and the surfaces (P < 0.05) included in the study. However, there is no significance in the mean adherence of microorganisms in the different quadrants (P > 0.05) included in the study. The interaction of bracket/surface, bracket/quadrant, surface/quadrants was analyzed, there was no significance of comparison of bracket/surfaces/quadrant but the interaction of bracket/quadrant was found to be significant (<0.011). The interaction of bracket/surfaces/quadrant was also found to be significant (<0.003). The maximum adherence of microorganisms was observed with the composite bracket material and the least adherence of microorganisms was observed with the titanium bracket material. The adherence of microorganisms is relatively more in the slot area, when compare to the tie wings surface maximum adherence of microorganism is observed in the upper left quadrant and least adherence of microorganism is observed in the lower right quadrant. There is a significant difference in adherence of microorganisms to various types of brackets and the surfaces included in the study. There is no significant difference in the adherence of microorganism to the bracket surfaces in the four quadrants included in the study.

  6. A Comparative Evaluation of Adherence of Microorganism to Different Types of Brackets: A Scanning Electron Microscopic Study

    PubMed Central

    Shashidhar, E P; Sahitya, M; Sunil, T; Murthy, Anup R; Rani, M S

    2015-01-01

    Background: The purpose of this study was to evaluate and compare the adherence of microorganism to different types of brackets using the scanning electron microscope (SEM). A double-blinded study was undertaken to evaluate and adherence of microorganisms to different types of brackets using SEM. Materials and Methods: At random, 12 patients reporting for treatment to the department of Orthodontics VS Dental College and Hospital were selected. Four types of brackets were included in the present study stainless steel, titanium, composite, and ceramic. Brackets were bonded to teeth of the patient on all the four quadrants. The teeth included for bonding were lateral incisor, canine, first premolar, and second premolar. The brackets were left for 72 h. After 72 h brackets were debonded, and they were evaluated by SEM for adherence of microorganism in the slot and tie wings surface. The SEM images were graded, and the adherence of microorganism to the brackets in the surfaces and the four different quadrants were recorded. Results: There is a significant difference in adherence of microorganisms to the various types of brackets (P < 0.001) and the surfaces (P < 0.05) included in the study. However, there is no significance in the mean adherence of microorganisms in the different quadrants (P > 0.05) included in the study. The interaction of bracket/surface, bracket/quadrant, surface/quadrants was analyzed, there was no significance of comparison of bracket/surfaces/quadrant but the interaction of bracket/quadrant was found to be significant (<0.011). The interaction of bracket/surfaces/quadrant was also found to be significant (<0.003). Conclusion: The maximum adherence of microorganisms was observed with the composite bracket material and the least adherence of microorganisms was observed with the titanium bracket material. The adherence of microorganisms is relatively more in the slot area, when compare to the tie wings surface maximum adherence of microorganism is observed in the upper left quadrant and least adherence of microorganism is observed in the lower right quadrant. There is a significant difference in adherence of microorganisms to various types of brackets and the surfaces included in the study. There is no significant difference in the adherence of microorganism to the bracket surfaces in the four quadrants included in the study. PMID:26435612

  7. Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique

    PubMed Central

    Arici, Nursel

    2015-01-01

    Objective The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. Methods Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a 0.017 × 0.025-in wire in the 0.018-in slots and a 0.019 × 0.025-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey's post-hoc test at the 95% confidence level (α = 0.05) were also used for statistical analyses. Results There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p < 0.001). The ceramic bracket with a 0.022-in stainless steel slot showed the lowest mean COF (µ = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (µ = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (µ = 0.85). Conclusions Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases. PMID:25667915

  8. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

    PubMed Central

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    ABSTRACT Objective: To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Methods: Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Results: Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. Conclusions: As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment. PMID:27653262

  9. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study.

    PubMed

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment.

  10. Analysis of Shear Bond Strength and Morphology of Er:YAG Laser-Recycled Ceramic Orthodontic Brackets

    PubMed Central

    Han, Ruo-qiao; Ji, Ling-fei; Ling, Chen

    2016-01-01

    Objective. The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. Materials and Methods. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Results. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p < 0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket. Conclusion. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods. PMID:27047964

  11. Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

    PubMed

    Kumar, Sujeet; Singh, Shamsher; Hamsa P R, Rani; Ahmed, Sameer; Prasanthma; Bhatnagar, Apoorva; Sidhu, Manreet; Shetty, Pramod

    2014-05-01

    The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). An experimental model which consisted of 5 aligned stainless steel 0.022-in brackets was used to assess frictional forces which were produced by SLBs (self ligating brackets) and CELs (conventional elastomeric ligatures) with use of 0.016 nickel titanium, 0.018 nickel titanium, 0.017 X 0.025"stainless steel and 0.019 X 0.025"stainless steel wires. One way ANOVA test was used to study the effect of the bracket type, wire alloy and section on frictional resistance test . Conventional brackets produced highest levels of friction for all bracket/archwire combinations. Both Damon III and Forestadent brackets were found to produce significantly lower levels of friction when they were compared with elastomerically tied conventional brackets. SLBs are valid alternatives for low friction during sliding mechanics.

  12. Laser-Aided Ceramic Bracket Debonding: A Comprehensive Review

    PubMed Central

    Ghazanfari, Rezvaneh; Nokhbatolfoghahaei, Hanieh; Alikhasi, Marzieh

    2016-01-01

    Different techniques have been introduced for the removal of ceramic brackets. Since the early 1990s, lasers have been used experimentally for debonding ceramic brackets. The goal of this study is to give a comprehensive literature review on laser-aided ceramic bracket debonding. PubMed and Google Scholar databases were used to identify dental articles with the following combination of key words: Ceramic brackets, Debonding, and Laser. Sixteen English articles from 2004 to 2015 were selected. The selected studies were categorized according to the variables investigated including the intrapulpal temperature, shear bond strength, debonding time, enamel damage and bracket failure. Most articles reported decreased shear bond strength and debonding time following laser irradiation without any critical and irritating increase in pulpal temperature. There were no reports of bracket failure or enamel damage. Laser irradiation is an efficient way to reduce shear bond strength of ceramic bracket and debonding time. This technique is a safe way for removing ceramic bracket with minimal impact on intrapulpal temperature and enamel surface and it reduces ceramic bracket failure. PMID:27330690

  13. Using chloride and chlorine-36 as soil-water tracers to estimate deep percolation at selected locations on the U.S. Department of Energy Hanford Site, Washington

    USGS Publications Warehouse

    Prych, Edmund A.

    1998-01-01

    A chloride mass-balance method and a chlorine-36 isotope bomb-pulse method were used to estimate long-term average rates of deep percolation at at the U.S. Department of Energy Hanford Site. Because the bomb-pulse method typically gives an upper limit and the mass-balance method may underestimate, estimates from both methods probably bracket actual rates.

  14. Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study

    PubMed Central

    Karim Soltani, Mohammad; Golfeshan, Farzaneh; Alizadeh, Yoones; Mehrzad, Jabraiel

    2015-01-01

    Statement of the Problem Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. Purpose The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. Materials and Method The samples included 4 types of brackets; metallic and clear Damon brackets and metallic and clear conventional brackets (10 brackets in each group). In this study, stainless steel wires sized 0.019×0.025 were employed and the operator’s saliva was used to simulate the conditions of oral cavity. The tidy-modified design was used for simulation of sliding movement. The resistance to sliding and static frictional forces was measured by employing Testometric machine and load cell. Results The mean (±SD) of resistance to sliding was 194.88 (±26.65) and 226.62 (±39.9) g in the esthetic and metallic Damon brackets, while these values were 187.81(±27.84) and 191.17(±66.68) g for the clear and metallic conventional brackets, respectively. Static frictional forces were 206.4(±42.45) and 210.38(±15.89) g in the esthetic and metallic Damon brackets and 220.63(±49.29) and 215.13(±62.38) g in the clear and metallic conventional brackets. According to two-way ANOVA, no significant difference was observed between the two bracket materials (clear and metal) and the two types of bracket (self-ligating versus conventional) regarding resistance to sliding (p= 0.17 and p= 0.23, respectively) and static frictional forces (p= 0.55 and p= 0.96, respectively). Conclusion Neither the type of bracket materials nor their type of ligation made difference in resistance to sliding and static friction. PMID:26106630

  15. Bracketing as a skill in conducting unstructured qualitative interviews.

    PubMed

    Sorsa, Minna Anneli; Kiikkala, Irma; Åstedt-Kurki, Päivi

    2015-03-01

    To provide an overview of bracketing as a skill in unstructured qualitative research interviews. Researchers affect the qualitative research process. Bracketing in descriptive phenomenology entails researchers setting aside their pre-understanding and acting non-judgementally. In interpretative phenomenology, previous knowledge is used intentionally to create new understanding. A literature search of bracketing in phenomenology and qualitative research. This is a methodology paper examining the researchers' impact in creating data in creating data in qualitative research. Self-knowledge, sensitivity and reflexivity of the researcher enable bracketing. Skilled and experienced researchers are needed to use bracketing in unstructured qualitative research interviews. Bracketing adds scientific rigour and validity to any qualitative study.

  16. Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash.

    PubMed

    Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis

    2015-01-01

    Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05). Corrosion rate of brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them.

  17. Quantitative analysis of enamel on debonded orthodontic brackets.

    PubMed

    Cochrane, Nathan J; Lo, Thomas W G; Adams, Geoffrey G; Schneider, Paul M

    2017-09-01

    Iatrogenic damage to the tooth surface in the form of enamel tearouts can occur during removal of fixed orthodontic appliances. The aim of this study was to assess debonded metal and ceramic brackets attached with a variety of bonding materials to determine how frequently this type of damage occurs. Eighty-one patients close to finishing fixed orthodontic treatment were recruited. They had metal brackets bonded with composite resin and a 2-step etch-and-bond technique or ceramic brackets bonded with composite resin and a 2-step etch-and- bond technique, and composite resin with a self-etching primer or resin-modified glass ionomer cement. Debonded brackets were examined by backscattered scanning electron microscopy with energy dispersive x-ray spectroscopy to determine the presence and area of enamel on the base pad. Of the 486 brackets collected, 26.1% exhibited enamel on the bonding material on the bracket base pad. The incidences of enamel tearouts for each group were metal brackets, 13.3%; ceramic brackets, 30.2%; composite resin with self-etching primer, 38.2%; and resin-modified glass ionomer cement, 21.2%. The percentage of the bracket base pad covered in enamel was highly variable, ranging from 0% to 46.1%. Enamel damage regularly occurred during the debonding process with the degree of damage being highly variable. Damage occurred more frequently when ceramic brackets were used (31.9%) compared with metal brackets (13.3%). Removal of ceramic brackets bonded with resin-modified glass ionomer cement resulted in less damage compared with the resin bonding systems. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of the friction force generated by monocristalyne and policristalyne ceramic brackets in sliding mechanics.

    PubMed

    Pimentel, Roberta Ferreira; de Oliveira, Roberto Sotto Maior Fortes; Chaves, Maria das Graças Afonso Miranda; Elias, Carlos Nelson; Gravina, Marco Abdo

    2013-01-01

    To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu) and one type of sapphire monocrystalline bracket (Radiance) in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. Tests were performed in dry and artificial saliva wet setting (Oral Balance) by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in) brackets (n = 18 for each bracket). In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu), an increase of friction was observed in its presence. The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.

  19. Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets.

    PubMed

    Papageorgiou, Spyridon N; Sifakakis, Iosif; Doulis, Ioannis; Eliades, Theodore; Bourauel, Christoph

    2016-01-01

    The aim of this study was to compare the torque efficacy of square and rectangular wires in 0.018- and 0.022-in. conventionally ligated brackets. Brackets of the same prescription were evaluated in both slot dimensions. Identical acrylic resin models of the maxilla were bonded with the brackets and mounted on the Orthodontic Measurement and Simulation System. Ten 0.018 × 0.018 in., 0.018 × 0.022 in., and 0.018 × 0.025 in. stainless steel wires were evaluated in the 0.018-in. brackets and ten 0.019 × 0.019 in., 0.019 × 0.025 in., and 0.019 × 0.026 in. stainless steel wires were evaluated in the 0.022-in. brackets. A 15° buccal root torque was gradually applied to the right central incisor bracket, and the moments were recorded at this position. One-way ANOVA was applied for both bracket slot sizes along with post hoc analysis for the various archwire sizes. The mean measured moments varied between 10.78 and 30.60 Nmm among the assessed wire-and-bracket combinations. Both square and rectangular archwires in the 0.018-in. bracket system exerted statistically significantly higher moments in comparison with their counterparts in the 0.022-in. bracket system. Rectangular archwires exerted statistically significantly higher moments than square archwires, both for the 0.018- and the 0.022-in. bracket system. Rectangular archwires seem to be more efficient in torque exertion, especially in 0.018-in. brackets.

  20. Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash

    PubMed Central

    Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis

    2015-01-01

    Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05). Corrosion rate of brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them. PMID:26697148

  1. Topographic and chemical surface modifications to metal brackets after a period in the mouth.

    PubMed

    Houb-Dine, Afaf; Bahije, Loubna; Oualalou, Youssef; Benyahia, Hicham; Zaoui, Fatima

    2017-09-01

    In the current state of our knowledge, the effects of corrosion on the performance of orthodontic appliances and on patient health are far from clear. Awareness of these problems has led to a growing demand for nickel-free products. Titanium brackets were recently launched on the market as an alternative to stainless-steel brackets. However, the use of fluorides for caries prevention creates a risk of corrosion of these titanium appliances. The aim of this study is to examine the corrosion of stainless-steel and titanium brackets in clinical orthodontic use, focusing on the impact of fluorine. After approval by the ethics committee and the informed consent of the patients, 30 candidates for multi-bracket treatment were selected on the basis of certain exclusion criteria. The patients were divided into 4 groups: group 1: titanium brackets and fluorine protection; group 2: titanium brackets without fluorine protection; group 3: stainless-steel brackets and fluorine protection; group 4: stainless-steel brackets without fluorine protection. Analysis of the brackets removed after 4months in the mouth, using scanning electron microscopy (SEM) with phase contrast, revealed a difference in the surface topography of the metal brackets and the presence of chromium coating on the surface of the titanium appliances. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  2. Evaluation of Static Friction of Polycrystalline Ceramic Brackets after Conditioning with Different Powers of Er:YAG Laser.

    PubMed

    Arash, Valiollah; Javanmard, Saeed; Eftekhari, Zeinab; Rahmati-Kamel, Manouchehr; Bahadoram, Mohammad

    2015-01-01

    This research aimed to reduce the friction between the wire and brackets by Er:YAG laser. To measure the friction between the wires and brackets in 0° and 10° of wire angulations, 40 polycrystalline ceramic brackets (Hubit, South Korea) were divided into 8 study groups and irradiated by 100, 200, and 300 mj/s of Er:YAG laser power. Two groups of brackets were not irradiated. The friction between the wires and brackets was measured with universal testing machine (SANTAM) with a segment of .019 × .025 SS wire pulled out of the slot of bracket. ANOVA and t-test were used for analyzing the results. To evaluate the effect of the laser on surface morphology of the bracket, SEM evaluations were carried out. The mean frictional resistances between the brackets and wires with 0° of angulation by increasing the laser power decreased compared with control group, but, in 10° of angulation, the friction increased regardless of the laser power and was comparable to the friction of nonirradiated brackets. Furthermore, with each laser power, frictional resistance of brackets in 10° of angulation was significantly higher than 0° of angulation. These results were explained by SEM images too.

  3. The reliability and validity of subjective notational analysis in comparison to global positioning system tracking to assess athlete movement patterns.

    PubMed

    Doğramac, Sera N; Watsford, Mark L; Murphy, Aron J

    2011-03-01

    Subjective notational analysis can be used to track players and analyse movement patterns during match-play of team sports such as futsal. The purpose of this study was to establish the validity and reliability of the Event Recorder for subjective notational analysis. A course was designed, replicating ten minutes of futsal match-play movement patterns, where ten participants undertook the course. The course allowed a comparison of data derived from subjective notational analysis, to the known distances of the course, and to GPS data. The study analysed six locomotor activity categories, focusing on total distance covered, total duration of activities and total frequency of activities. The values between the known measurements and the Event Recorder were similar, whereas the majority of significant differences were found between the Event Recorder and GPS values. The reliability of subjective notational analysis was established with all ten participants being analysed on two occasions, as well as analysing five random futsal players twice during match-play. Subjective notational analysis is a valid and reliable method of tracking player movements, and may be a preferred and more effective method than GPS, particularly for indoor sports such as futsal, and field sports where short distances and changes in direction are observed.

  4. Using a color-coded ambigraphic nucleic acid notation to visualize conserved palindromic motifs within and across genomes

    PubMed Central

    2014-01-01

    Background Ambiscript is a graphically-designed nucleic acid notation that uses symbol symmetries to support sequence complementation, highlight biologically-relevant palindromes, and facilitate the analysis of consensus sequences. Although the original Ambiscript notation was designed to easily represent consensus sequences for multiple sequence alignments, the notation’s black-on-white ambiguity characters are unable to reflect the statistical distribution of nucleotides found at each position. We now propose a color-augmented ambigraphic notation to encode the frequency of positional polymorphisms in these consensus sequences. Results We have implemented this color-coding approach by creating an Adobe Flash® application ( http://www.ambiscript.org) that shades and colors modified Ambiscript characters according to the prevalence of the encoded nucleotide at each position in the alignment. The resulting graphic helps viewers perceive biologically-relevant patterns in multiple sequence alignments by uniquely combining color, shading, and character symmetries to highlight palindromes and inverted repeats in conserved DNA motifs. Conclusion Juxtaposing an intuitive color scheme over the deliberate character symmetries of an ambigraphic nucleic acid notation yields a highly-functional nucleic acid notation that maximizes information content and successfully embodies key principles of graphic excellence put forth by the statistician and graphic design theorist, Edward Tufte. PMID:24447494

  5. A systematic investigation of the link between rational number processing and algebra ability.

    PubMed

    Hurst, Michelle; Cordes, Sara

    2018-02-01

    Recent research suggests that fraction understanding is predictive of algebra ability; however, the relative contributions of various aspects of rational number knowledge are unclear. Furthermore, whether this relationship is notation-dependent or rather relies upon a general understanding of rational numbers (independent of notation) is an open question. In this study, college students completed a rational number magnitude task, procedural arithmetic tasks in fraction and decimal notation, and an algebra assessment. Using these tasks, we measured three different aspects of rational number ability in both fraction and decimal notation: (1) acuity of underlying magnitude representations, (2) fluency with which symbols are mapped to the underlying magnitudes, and (3) fluency with arithmetic procedures. Analyses reveal that when looking at the measures of magnitude understanding, the relationship between adults' rational number magnitude performance and algebra ability is dependent upon notation. However, once performance on arithmetic measures is included in the relationship, individual measures of magnitude understanding are no longer unique predictors of algebra performance. Furthermore, when including all measures simultaneously, results revealed that arithmetic fluency in both fraction and decimal notation each uniquely predicted algebra ability. Findings are the first to demonstrate a relationship between rational number understanding and algebra ability in adults while providing a clearer picture of the nature of this relationship. © 2017 The British Psychological Society.

  6. Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

    PubMed

    Nayak, Rabindra S; Shafiuddin, Bareera; Pasha, Azam; Vinay, K; Narayan, Anjali; Shetty, Smitha V

    2015-07-01

    Technological advances in wire selection and bracket design have led to improved treatment efficiency and allowed longer time intervals between appliance adjustments. The wires remain in the mouth for a longer duration and are subjected to electrochemical reactions, mechanical forces of mastication and generalized wear. These cause different types of corrosion. This study was done to compare the galvanic currents generated between different combinations of brackets and archwires commonly used in orthodontic practices. The materials used for the study included different commercially available orthodontic archwires and brackets. The galvanic current generated by individual materials and different combinations of these materials was tested and compared. The orthodontic archwires used were 0.019″ × 0.025″ heat-activated nickel-titanium (3M Unitek), 0.019″ × 0.025″ beta-titanium (3M Unitek) and 0.019″ × 0.025″ stainless steel (3M Unitek). The orthodontic brackets used were 0.022″ MBT laser-cut (Victory Series, 3M Unitek) and metal-injection molded (Leone Company) maxillary central incisor brackets respectively. The ligature wire used for ligation was 0.009″ stainless steel ligature (HP Company). The galvanic current for individual archwires, brackets, and the different bracket-archwire-ligature combinations was measured by using a Potentiostat machine. The data were generated using the Linear Sweep Voltammetry and OriginPro 8.5 Graphing and Data Analysis Softwares. The study was conducted in two phases. Phase I comprised of five groups for open circuit potential (OCP) and galvanic current (I), whereas Phase II comprised of six groups for galvanic current alone. Mean, standard deviation and range were computed for the OCP and galvanic current (I) values obtained. Results were subjected to statistical analysis through ANOVA. In Phase I, higher mean OCP was recorded in stainless steel archwire, followed by beta-titanium archwire, heat-activated nickel titanium archwire, laser-cut bracket and metal-injection molded bracket, respectively. The difference in mean OCP recorded among the groups was found to be statistically significant in aerated phosphate buffered saline solution. The galvanic current (I) for metal-injection molded stainless steel brackets showed significantly higher values than all the other materials. Phase II results suggested that, in the couples formed by the archwire-bracket-ligature combinations, the bracket had more important contribution to the total galvanic current generated, since there were significant differences between galvanic current among the 2 brackets tested but not among the 3 wires. The galvanic current of the metal-injection molded bracket was significantly higher than that of laser-cut bracket. Highest mean current (I) was recorded in metal-injection molded bracket when used with heat-activated nickel titanium archwire while lowest mean current (I) was recorded in laser-cut bracket when used with beta-titanium archwire. The present study concluded that the bracket emerged to be the most important factor in determining the galvanic current (I). Higher mean current (I) was recorded in metal-injection molded bracket compared to laser-cut bracket. Among the three archwires, higher mean current (I) was recorded in heat-activated nickel-titanium, followed by stainless-steel and beta-titanium respectively. When coupled together; highest mean current (I) was recorded in metal-injection molded bracket when used with heat-activated nickel titanium archwire while lowest mean current (I) was recorded in laser-cut bracket when used with beta-titanium archwire.

  7. Effects of femtosecond laser and other surface treatments on the bond strength of metallic and ceramic orthodontic brackets to zirconia

    PubMed Central

    García-Sanz, Verónica; Bellot-Arcís, Carlos; Mendoza-Yero, Omel; Doñate-Buendía, Carlos; Montero, Javier; Albaladejo, Alberto

    2017-01-01

    Femtosecond laser has been proposed as a method for conditioning zirconia surfaces to boost bond strength. However, metallic or ceramic bracket bonding to femtosecond laser-treated zirconia surfaces has not been tested. This study compared the effects of four conditioning techniques, including femtosecond laser irradiation, on shear bond strength (SBS) of metallic and ceramic brackets to zirconia.Three hundred zirconia plates were divided into five groups: 1) control (C); 2) sandblasting (APA); 3) silica coating and silane (SC); 4) femtosecond laser (FS); 5) sandblasting followed by femtosecond laser (APA+SC). A thermal imaging camera measured temperature changes in the zirconia during irradiation. Each group was divided into 2 subgroups (metallic vs ceramic brackets). SBS was evaluated using a universal testing machine. The adhesive remnant index (ARI) was registered and surfaces were observed under SEM. Surface treatment and bracket type significantly affected the bracket-zirconia bond strength. SBS was significantly higher (p<0.001) for ceramic brackets in all groups (APA+FS > APA > FS > SC > control) than metallic brackets (APA+FS > FS > SC > APA > control). For metallic brackets, groups SC (5.99 ± 1.86 MPa), FS (6.72 ± 2.30 MPa) and APA+FS (7.22 ± 2.73 MPa) reported significantly higher bond strengths than other groups (p < 0.05). For ceramic brackets, the highest bond strength values were obtained in groups APA (25.01 ± 4.45 MPa), FS (23.18 ± 6.51 MPa) and APA+FS (29.22 ± 8.20 MPa).Femtosecond laser enhances bond strength of ceramic and metallic brackets to zirconia. Ceramic brackets provide significantly stronger adhesion than metallic brackets regardless of the surface treatment method. PMID:29049418

  8. Shear Bond Strength of Orthodontic Brackets Bonded to Zirconium Crowns

    PubMed Central

    Mehmeti, Blerim; Azizi, Bleron; Kelmendi, Jeta; Iljazi-Shahiqi, Donika; Alar, Željko

    2017-01-01

    Background An increasing demand for esthetic restorations has resulted in an increased use of all-ceramic restorations, such as zirconium. However, one of the challenges the orthodontist must be willing to face is how to increase bond strength between the brackets and various ceramic restorations.Bond strength can beaffected bybracket type, by the material that bracketsaremade of, and their base surface design or retention mode. ​ Aim: of this study was to perform a comparative analysis of the shear bond strength (SBS) of metallic and ceramic orthodontic brackets bonded to all-zirconium ceramic surfaces used for prosthetic restorations, and also to evaluate the fracture mode of these two types of orthodontic brackets. Material and methods Twenty samples/semi-crowns of all-zirconium ceramic, on which orthodontic brackets were bonded, 10 metallic and 10 ceramic polycrystalline brackets, were prepared for this research. SBS has been testedby Universal Testing Machine, with a load applied using a knife edged rod moving at a fixed rate of 1 mm/min, until failure occurred. The force required to debond the brackets was recorded in Newton, then SBS was calculated to MPa. In addition, the samples were analyzed using a digital camera magnifier to determine Adhesive Remnant Index (ARI). Statistical data were processed using t-test, and the level of significance was set at α = 0.05. Results Higher shear bond strength values were observed in metallic brackets bonded to zirconium crowns compared tothoseof ceramic brackets, with a significant difference. During the test, two of the ceramic brackets were partially or totally damaged. Conclusion Metallic brackets, compared to ceramic polycrystalline brackets, seemed tocreate stronger adhesion with all-zirconium surfaces due to their better retention mode. Also, ceramic brackets showed higher fragility during debonding. PMID:28827846

  9. Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets.

    PubMed

    Yassaei, Soghra; Aghili, Hossein; Hosseinzadeh Firouzabadi, Azadeh; Meshkani, Hamidreza

    2017-01-01

    Introduction: This study was performed to determine the shear bond strength of rebonded mechanically retentive ceramic brackets after recycling with Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser or sandblasting. Methods: Twenty-eight debonded ceramic brackets plus 14 intact new ceramic brackets were used in this study. Debonded brackets were randomly divided into 2 groups of 14. One group was treated by Er:YAG laser and the other with sandblasting. All the specimens were randomly bonded to 42 intact human upper premolars. The shear bond strength of all specimens was determined with a universal testing machine at a crosshead speed of 0.5 mm/min until bond failure occurred. The recycled bracket base surfaces were observed under a scanning electron microscope (SEM). Analysis of variance (ANOVA) and Tukey tests were used to compare the shear bond strength of the 3 groups. Fisher exact test was used to evaluate the differences in adhesive remnant index (ARI) scores. Results: The highest bond strength belonged to brackets recycled by Sandblasting (16.83 MPa). There was no significant difference between the shear bond strength of laser and control groups. SEM photographs showed differences in 2 recycling methods. The laser recycled bracket appeared to have as well-cleaned base as the new bracket. Although the sandblasted bracket photographs showed no remnant adhesives, remarkable micro-roughening of the base of the bracket was apparent. Conclusion: According to the results of this study, both Er:YAG laser and sandblasting were efficient to mechanically recondition retentive ceramic brackets. Also, Er:YAG laser did not change the design of bracket base while removing the remnant adhesives which might encourage its application in clinical practice.

  10. Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets

    PubMed Central

    Yassaei, Soghra; Aghili, Hossein; Hosseinzadeh Firouzabadi, Azadeh; Meshkani, Hamidreza

    2017-01-01

    Introduction: This study was performed to determine the shear bond strength of rebonded mechanically retentive ceramic brackets after recycling with Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser or sandblasting. Methods: Twenty-eight debonded ceramic brackets plus 14 intact new ceramic brackets were used in this study. Debonded brackets were randomly divided into 2 groups of 14. One group was treated by Er:YAG laser and the other with sandblasting. All the specimens were randomly bonded to 42 intact human upper premolars. The shear bond strength of all specimens was determined with a universal testing machine at a crosshead speed of 0.5 mm/min until bond failure occurred. The recycled bracket base surfaces were observed under a scanning electron microscope (SEM). Analysis of variance (ANOVA) and Tukey tests were used to compare the shear bond strength of the 3 groups. Fisher exact test was used to evaluate the differences in adhesive remnant index (ARI) scores. Results: The highest bond strength belonged to brackets recycled by Sandblasting (16.83 MPa). There was no significant difference between the shear bond strength of laser and control groups. SEM photographs showed differences in 2 recycling methods. The laser recycled bracket appeared to have as well-cleaned base as the new bracket. Although the sandblasted bracket photographs showed no remnant adhesives, remarkable micro-roughening of the base of the bracket was apparent. Conclusion: According to the results of this study, both Er:YAG laser and sandblasting were efficient to mechanically recondition retentive ceramic brackets. Also, Er:YAG laser did not change the design of bracket base while removing the remnant adhesives which might encourage its application in clinical practice. PMID:28912939

  11. Shear Bond Strength of Orthodontic Brackets Bonded to Zirconium Crowns.

    PubMed

    Mehmeti, Blerim; Azizi, Bleron; Kelmendi, Jeta; Iljazi-Shahiqi, Donika; Alar, Željko; Anić-Milošević, Sandra

    2017-06-01

    An increasing demand for esthetic restorations has resulted in an increased use of all-ceramic restorations, such as zirconium. However, one of the challenges the orthodontist must be willing to face is how to increase bond strength between the brackets and various ceramic restorations.Bond strength can beaffected bybracket type, by the material that bracketsaremade of, and their base surface design or retention mode. ​: A im: of this study was to perform a comparative analysis of the shear bond strength (SBS) of metallic and ceramic orthodontic brackets bonded to all-zirconium ceramic surfaces used for prosthetic restorations, and also to evaluate the fracture mode of these two types of orthodontic brackets. Twenty samples/semi-crowns of all-zirconium ceramic, on which orthodontic brackets were bonded, 10 metallic and 10 ceramic polycrystalline brackets, were prepared for this research. SBS has been testedby Universal Testing Machine, with a load applied using a knife edged rod moving at a fixed rate of 1 mm/min, until failure occurred. The force required to debond the brackets was recorded in Newton, then SBS was calculated to MPa. In addition, the samples were analyzed using a digital camera magnifier to determine Adhesive Remnant Index (ARI). Statistical data were processed using t-test, and the level of significance was set at α = 0.05. Higher shear bond strength values were observed in metallic brackets bonded to zirconium crowns compared tothoseof ceramic brackets, with a significant difference. During the test, two of the ceramic brackets were partially or totally damaged. Metallic brackets, compared to ceramic polycrystalline brackets, seemed tocreate stronger adhesion with all-zirconium surfaces due to their better retention mode. Also, ceramic brackets showed higher fragility during debonding.

  12. Effects of femtosecond laser and other surface treatments on the bond strength of metallic and ceramic orthodontic brackets to zirconia.

    PubMed

    García-Sanz, Verónica; Paredes-Gallardo, Vanessa; Bellot-Arcís, Carlos; Mendoza-Yero, Omel; Doñate-Buendía, Carlos; Montero, Javier; Albaladejo, Alberto

    2017-01-01

    Femtosecond laser has been proposed as a method for conditioning zirconia surfaces to boost bond strength. However, metallic or ceramic bracket bonding to femtosecond laser-treated zirconia surfaces has not been tested. This study compared the effects of four conditioning techniques, including femtosecond laser irradiation, on shear bond strength (SBS) of metallic and ceramic brackets to zirconia.Three hundred zirconia plates were divided into five groups: 1) control (C); 2) sandblasting (APA); 3) silica coating and silane (SC); 4) femtosecond laser (FS); 5) sandblasting followed by femtosecond laser (APA+SC). A thermal imaging camera measured temperature changes in the zirconia during irradiation. Each group was divided into 2 subgroups (metallic vs ceramic brackets). SBS was evaluated using a universal testing machine. The adhesive remnant index (ARI) was registered and surfaces were observed under SEM. Surface treatment and bracket type significantly affected the bracket-zirconia bond strength. SBS was significantly higher (p<0.001) for ceramic brackets in all groups (APA+FS > APA > FS > SC > control) than metallic brackets (APA+FS > FS > SC > APA > control). For metallic brackets, groups SC (5.99 ± 1.86 MPa), FS (6.72 ± 2.30 MPa) and APA+FS (7.22 ± 2.73 MPa) reported significantly higher bond strengths than other groups (p < 0.05). For ceramic brackets, the highest bond strength values were obtained in groups APA (25.01 ± 4.45 MPa), FS (23.18 ± 6.51 MPa) and APA+FS (29.22 ± 8.20 MPa).Femtosecond laser enhances bond strength of ceramic and metallic brackets to zirconia. Ceramic brackets provide significantly stronger adhesion than metallic brackets regardless of the surface treatment method.

  13. Impact of bracket displacement or rotation during bonding and time of removal of excess adhesive on the bracket-enamel bond strength.

    PubMed

    Oliveira, Adauê S; Barwaldt, Caroline K; Bublitz, Luana S; Moraes, Rafael R

    2014-06-01

    This study investigated the the influence of bracket displacement or rotation during fixation and the time of excess adhesive removal from around the bracket on bond strength to enamel. Stainless steel brackets were bonded to the buccal faces of bovine incisors using Transbond XT® adhesive resin. The teeth were divided into five groups (n = 20). In the control group, no displacement or rotation of the bracket was carried out. In the Displac-A group, excess adhesive was removed after the bracket was displaced 2 mm incisally. In the B-Displac group, excess adhesive was removed before the bracket was displaced incisally. In the Rotat-A group, excess adhesive was removed after the bracket was rotated 45°. In the B-Rotat group, excess adhesive was removed before the bracket was rotated. Photoactivation was carried out on the lateral sides of the bracket. A shear test was conducted 10 min after fixation using a knife-edged chisel. Bond strength data were analysed using ANOVA and Fisher's test (5%). The adhesive remnant index (ARI) was scored under magnification. ARI data were analysed using the Kruskal-Wallis test (5%). No significant differences were detected among the Control, Displac-A, Rotat-A and B-Rotat groups. The B-Displac group showed lower bond strength than all of the other groups, except Displac-A. No significant differences were observed in ARI scores across groups. Displacements of the brackets during fixation did not seem to affect the enamel bond strength when excess adhesive is removed after the final positioning of the bracket. © 2014 British Orthodontic Society.

  14. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets

    PubMed Central

    Kannan, M. S.; Murali, R. V.; Kishorekumar, S.; Gnanashanmugam, K.; Jayanth, V.

    2015-01-01

    Aim: The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope) study of the Brackets after Frictional evaluation. Materials and Methods: Two types of self-ligating esthetic brackets, Damon clear (Ormco) made of fully ceramic and Opal (Ultradent Products, USA) and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek) and Damon 3 (Ormco) both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA) and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. Results: The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets). For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05) than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets) which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets) generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets) generated smaller amount of frictional forces when compared with Damon clear and relatively higher amount of frictional forces when compared to Opal and Damon 3 PMID:26015687

  15. In vitro evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires

    PubMed Central

    Arash, Valiollah; Rabiee, Mahmoud; Rakhshan, Vahid; Khorasani, Sara; Sobouti, Farhad

    2015-01-01

    Purpose: The aim of this study was to compare frictional forces between monocrystalline alumina (MA), polycrystalline alumina (PA), and stainless steel (SS) brackets with two SS wires: Rectangular and round. Materials and Methods: In this in vitro study, 60 0.022 brackets [20 PA (0° torque, Forestadent, Germany) and 20 MA (0° torque, Ormco, California, USA)] brackets plus 20 SS brackets (0° torque, Foretadent, Germany) and 60 SS archwires (30 rectangular 0.019 ×0.025 archwires and 30 round 0.018 archwires, Ortho Technology, USA) were used in subgroups of 10 from the combination of all brackets and all archwires. A universal testing machine (Instron, Model STM 250, Germany) was used to investigate the static frictional resistance. The angulation between the bracket and wire was 0°, and the wires were pulled through the slots at a crosshead speed of 10 mm/min. Two-way and one-way analyses of variance (ANOVA) and Tukey tests were used to analyze the data. Results: Mean (SD) static frictional force for each group was as follows: MA + round: 3.47 (0.38); MA + rectangular: 4.05 (0.47); PA + round: 4.14 (0.37); PA + rectangular: 4.45 (0.65); SS + round: 3.28 (0.22); and SS + rectangular: 4.22 (0.61). Significant effects of bracket types (P = 0.001) and archwire types (P = 0.000) on the friction force were detected using ANOVA. Tukey test indicated significant differences between PA brackets with both SS and MA brackets (P < 0.05), but not between SS and MA brackets. The two archwires as well had significantly different effects (Tukey P = 0.000). Conclusions: Based on the present in-vitro study, the PA brackets might create higher frictional forces compared to both SS and MA brackets. The rectangular 0.019 ×0.025 archwire might create greater forces than round 0.018 archwire. PMID:26020037

  16. In vitro evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires.

    PubMed

    Arash, Valiollah; Rabiee, Mahmoud; Rakhshan, Vahid; Khorasani, Sara; Sobouti, Farhad

    2015-01-01

    The aim of this study was to compare frictional forces between monocrystalline alumina (MA), polycrystalline alumina (PA), and stainless steel (SS) brackets with two SS wires: Rectangular and round. In this in vitro study, 60 0.022 brackets [20 PA (0° torque, Forestadent, Germany) and 20 MA (0° torque, Ormco, California, USA)] brackets plus 20 SS brackets (0° torque, Foretadent, Germany) and 60 SS archwires (30 rectangular 0.019 ×0.025 archwires and 30 round 0.018 archwires, Ortho Technology, USA) were used in subgroups of 10 from the combination of all brackets and all archwires. A universal testing machine (Instron, Model STM 250, Germany) was used to investigate the static frictional resistance. The angulation between the bracket and wire was 0°, and the wires were pulled through the slots at a crosshead speed of 10 mm/min. Two-way and one-way analyses of variance (ANOVA) and Tukey tests were used to analyze the data. Mean (SD) static frictional force for each group was as follows: MA + round: 3.47 (0.38); MA + rectangular: 4.05 (0.47); PA + round: 4.14 (0.37); PA + rectangular: 4.45 (0.65); SS + round: 3.28 (0.22); and SS + rectangular: 4.22 (0.61). Significant effects of bracket types (P = 0.001) and archwire types (P = 0.000) on the friction force were detected using ANOVA. Tukey test indicated significant differences between PA brackets with both SS and MA brackets (P < 0.05), but not between SS and MA brackets. The two archwires as well had significantly different effects (Tukey P = 0.000). Based on the present in-vitro study, the PA brackets might create higher frictional forces compared to both SS and MA brackets. The rectangular 0.019 ×0.025 archwire might create greater forces than round 0.018 archwire.

  17. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

    PubMed

    Mirzakouchaki, Behnam; Shirazi, Sajjad; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-02-01

    Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch.

  18. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets.

    PubMed

    Kannan, M S; Murali, R V; Kishorekumar, S; Gnanashanmugam, K; Jayanth, V

    2015-04-01

    The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope) study of the Brackets after Frictional evaluation. Two types of self-ligating esthetic brackets, Damon clear (Ormco) made of fully ceramic and Opal (Ultradent Products, USA) and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek) and Damon 3 (Ormco) both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA) and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets). For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05) than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets) which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets) generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets) generated smaller amount of frictional forces when compared with Damon clear and relatively higher amount of frictional forces when compared to Opal and Damon 3.

  19. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study

    PubMed Central

    Mirzakouchaki, Behnam; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-01-01

    Background Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. Material and Methods 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. Results The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. Conclusions The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. PMID:26855704

  20. Material testing of reconditioned orthodontic brackets.

    PubMed

    Reimann, S; Rewari, A; Keilig, L; Widu, F; Jäger, A; Bourauel, C

    2012-12-01

    While all manufacturers of orthodontic brackets label these products for single use, there are commercial providers offering bracket reconditioning (or "recycling"). We conducted this study to investigate the effects of different recycling techniques on material-related parameters in orthodontic brackets, aiming to derive indications for clinical use and conclusions about the biocompatibility, longevity, and application of recycled brackets. New metal brackets (equilibrium(®); Dentaurum, Ispringen, Germany) were compared to brackets recycled by different techniques, including direct flaming with a Bunsen burner, chemical reconditioning in an acid bath, a commercial unit (Big Jane; Esmadent, IL, USA), and outsourcing to a company (Ortho Clean, Dellstedt, Germany). Material-related examinations included the following: (1) corrosion behavior by static immersion testing and use of a mass spectrometer to determine nickel-ion concentrations in the corrosive medium, (2) surface features in scanning electron micrographs before and after corrosion testing, (3) Vickers hardness using a hardness testing machine, (4) shear bond strength as defined in DIN 13990-1, (5) dimensional stability of the bracket slots by light microscopy, and (6) frictional loss as assessed by an orthodontic measurement and simulation system (OMSS). Each examination was performed on ten brackets. Student's t-test was used for statistical analysis. Compared to the new brackets, those recycled in an acid bath or by a commercial provider revealed significant dimensional changes (p<0.05). Corrosion on the recycled brackets varied according to the recycling techniques employed. The group of brackets recycled by one company revealed hardness values that differed from those of all the other groups. No significant differences were observed in nickel-ion release, frictional loss, and shear bond strength. Recycling was found to significantly reduce the corrosion resistance and dimensional stability of orthodontic brackets. As the savings generated by recycling do not justify the risks involved, the practice of labeling orthodontic brackets for single use remains a responsible precaution that safeguards patients and orthodontists against definite risks.

  1. Debris and friction of self-ligating and conventional orthodontic brackets after clinical use.

    PubMed

    Araújo, Raíssa Costa; Bichara, Lívia Monteiro; Araujo, Adriana Monteiro de; Normando, David

    2015-07-01

    To compare the degree of debris and friction of conventional and self-ligating orthodontic brackets before and after clinical use. Two sets of three conventional and self-ligating brackets were bonded from the first molar to the first premolar in eight individuals, for a total of 16 sets per type of brackets. A passive segment of 0.019 × 0.025-inch stainless steel archwire was inserted into each group of brackets. Frictional force and debris level were evaluated as received and after 8 weeks of intraoral exposure. Two-way analysis of variance and Wilcoxon signed-rank test were applied at P < .05. After the intraoral exposure, there was a significant increase of debris accumulation in both systems of brackets (P < .05). However, the self-ligating brackets showed a higher amount of debris compared with the conventional brackets. The frictional force in conventional brackets was significantly higher when compared with self-ligating brackets before clinical use (P < .001). Clinical exposure for 8 weeks provided a significant increase of friction (P < .001) on both systems. In the self-ligating system, the mean of friction increase was 0.21 N (191%), while 0.52 N (47.2%) was observed for the conventional system. Self-ligating and conventional brackets, when exposed to the intraoral environment, showed a significant increase in frictional force during the sliding mechanics. Debris accumulation was higher for the self-ligating system.

  2. Understanding Charts and Graphs.

    DTIC Science & Technology

    1987-07-28

    34notational.* English, then, is obviously not a notational system because ambiguous words or sentences are possible, whereas musical notion is notational...how lines and regions are detected and organized; these principles grow out of discoveries about human visual information processing. A syntactic...themselves name other colors (e.g., the word "red" is printed in blue ink; this is known as the OStroop effecto ). Similarly, if "left" and "right" are

  3. Gap-minimal systems of notations and the constructible hierarchy

    NASA Technical Reports Server (NTRS)

    Lucian, M. L.

    1972-01-01

    If a constructibly countable ordinal alpha is a gap ordinal, then the order type of the set of index ordinals smaller than alpha is exactly alpha. The gap ordinals are the only points of discontinuity of a certain ordinal-valued function. The notion of gap minimality for well ordered systems of notations is defined, and the existence of gap-minimal systems of notations of arbitrarily large constructibly countable length is established.

  4. Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.

    PubMed

    Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B

    2017-03-01

    To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.

  5. Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play.

    PubMed

    Lee, Youngran; Lee, Dong-Yul; Kim, Yoon-Ji R

    2016-09-01

    To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). In all bracket systems, the slot tops were significantly wider than the slot bases (P < .001), yielding a divergent slot profile. Clarity-SLs (3M Unitek, Monrovia, Calif) showed the greatest divergence among the 0.022-inch brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 × 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 × 0.022-inch SS wire (Ortho Technology).

  6. Evaluation of Micro-organism in Ligated Metal and Self-ligating Brackets using Scanning Electron Microscopy: An In Vivo Study

    PubMed Central

    Sunil, P C; Michael, Tony; Raju, Aravind S; Paul, Renji K; Mamatha, J; Ebin, T M

    2015-01-01

    Background: The objective of the study was to determine the sites of plaque accumulation and to compare the plaque accumulated with metal and self-ligating orthodontic brackets in order to know which bracket type had a higher plaque retaining capacity. Materials and Methods: The study was done on 20 subjects who were scheduled for orthodontic treatment including extraction of four premolars and fixed orthodontic appliances. Mesh-backed edgewise metal brackets ligated with steel ligatures and self-ligating brackets were bonded to the premolars to be extracted using composite (Transbond XT, 3M). The subjects were told to continue their normal oral hygiene regimen. Teeth were extracted at 1, 2, and 3 weeks after bracket bonding. Plaque attached to the buccal surfaces was stained using plaque disclosing agent. The teeth were then immersed in fixative containing 4% formaldehyde and 1% glutaraldehyde in phosphate buffer for 24 h, followed by 0.1 M phosphate buffer for 12 h. The specimens were then mounted on aluminum stubs, and sputter coated with gold prior to Scanning electron microscopy examination. Results: The results showed that increased retention of plaque in metal brackets ligated with steel ligatures and comparatively less in self-ligating brackets at the base of the brackets. Conclusions: This study highlights that higher retention of plaque in metal brackets ligated with steel ligatures and comparatively less plaque retention in self-ligating brackets. Excess composite around the bracket base is the critical site of plaque accumulation associated with fixed appliances due to its rough surface texture. PMID:26229372

  7. Microbial complexes levels in conventional and self-ligating brackets.

    PubMed

    Bergamo, Ana Zilda Nazar; Nelson-Filho, Paulo; Andrucioli, Marcela Cristina Damião; do Nascimento, Cássio; Pedrazzi, Vinícius; Matsumoto, Mírian Aiko Nakane

    2017-05-01

    The aims were to evaluate the levels of bacterial species in saliva and in situ and to assess whether the design of brackets influences the risk of developing periodontal disease. Twenty patients (13.3 mean age) were bonded with self-ligating brackets and a conventional bracket. Saliva was collected before bonding and 30 and 60 days after bonding. One sample of each bracket was removed 30 and 60 days after bonding. The analysis was determined by checkerboard DNA-DNA hybridization. The data was evaluated by the non-parametric test. A significant increase in the levels of bacterial species in the saliva occurred in 15 of the 22 analyzed species. The self-ligating brackets presented the highest incidence percentages for the orange and red complexes 60 days after bonding. In situ analyses showed different patterns according to the bracket design. The levels of Campylobacter rectus showed significant differences (p = 0.011) 60 days after bonding among the three brackets; the highest values were observed in the In-Ovation®R bracket. The bracket design seems to influence the levels of bacterial species involved in periodontal disease. Considering the wide variety of bacterial species, additional studies are needed to aid in the establishment of effective protocols to prevent the development of periodontal disease during orthodontic treatment. A dynamic alteration in the oral microbiota may lead to inflammatory reactions in the supporting soft and hard tissues. The different types of brackets interfere with bacterial adherence. Bracket design should be considered in orthodontic treatment.

  8. The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets.

    PubMed

    Arash, Valiollah; Anoush, Keivan; Rabiee, Sayed Mahmood; Rahmatei, Manuchehr; Tavanafar, Saeid

    2015-01-01

    Aims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to the tooth. In an experimental clinical research 28 orthodontic brackets (standard, 22 slots) were coated with silver ions using electroplate method. Six brackets (coated: 3, uncoated: 3) were evaluated with Scanning Electron Microscopy and Atomic Force Microscopy. The amount of friction in 15 coated brackets was measured with three different kinds of arch wires (0.019 × 0.025-in stainless steel [SS], 0.018-in stainless steel [SS], 0.018-in Nickel-Titanium [Ni-Ti]) and compared with 15 uncoated steel brackets. In addition, shear bond strength values were compared between 10 brackets with silver coating and 10 regular brackets. Universal testing machine was used to measure shear bond strength and the amount of friction between the wires and brackets. SPSS 18 was used for data analysis with t-test. SEM and AFM results showed deposition of a uniform layer of silver, measuring 8-10 μm in thickness on bracket surfaces. Silver coating led to higher frictional forces in all the three types of arch wires, which was statistically significant in 0.019 × 0.025-in SS and 0.018-in Ni-Ti, but it did not change the shear bond strength significantly. Silver coating with electroplating method did not affect the bond strength of the bracket to enamel; in addition, it was not an effective method for decreasing friction in sliding mechanics. © Wiley Periodicals, Inc.

  9. Evaluation of Micro-organism in Ligated Metal and Self-ligating Brackets using Scanning Electron Microscopy: An In Vivo Study.

    PubMed

    Sunil, P C; Michael, Tony; Raju, Aravind S; Paul, Renji K; Mamatha, J; Ebin, T M

    2015-07-01

    The objective of the study was to determine the sites of plaque accumulation and to compare the plaque accumulated with metal and self-ligating orthodontic brackets in order to know which bracket type had a higher plaque retaining capacity. The study was done on 20 subjects who were scheduled for orthodontic treatment including extraction of four premolars and fixed orthodontic appliances. Mesh-backed edgewise metal brackets ligated with steel ligatures and self-ligating brackets were bonded to the premolars to be extracted using composite (Transbond XT, 3M). The subjects were told to continue their normal oral hygiene regimen. Teeth were extracted at 1, 2, and 3 weeks after bracket bonding. Plaque attached to the buccal surfaces was stained using plaque disclosing agent. The teeth were then immersed in fixative containing 4% formaldehyde and 1% glutaraldehyde in phosphate buffer for 24 h, followed by 0.1 M phosphate buffer for 12 h. The specimens were then mounted on aluminum stubs, and sputter coated with gold prior to Scanning electron microscopy examination. The results showed that increased retention of plaque in metal brackets ligated with steel ligatures and comparatively less in self-ligating brackets at the base of the brackets. This study highlights that higher retention of plaque in metal brackets ligated with steel ligatures and comparatively less plaque retention in self-ligating brackets. Excess composite around the bracket base is the critical site of plaque accumulation associated with fixed appliances due to its rough surface texture.

  10. Advancements in dynamic kill calculations for blowout wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kouba, G.E.; MacDougall, G.R.; Schumacher, B.W.

    1993-09-01

    This paper addresses the development, interpretation, and use of dynamic kill equations. To this end, three simple calculation techniques are developed for determining the minimum dynamic kill rate. Two techniques contain only single-phase calculations and are independent of reservoir inflow performance. Despite these limitations, these two methods are useful for bracketing the minimum flow rates necessary to kill a blowing well. For the third technique, a simplified mechanistic multiphase-flow model is used to determine a most-probable minimum kill rate.

  11. Factors affecting the shear bond strength of metal and ceramic brackets bonded to different ceramic surfaces.

    PubMed

    Abu Alhaija, Elham S J; Abu AlReesh, Issam A; AlWahadni, Ahed M S

    2010-06-01

    The aims of this study were to evaluate the shear bond strength (SBS) of metal and ceramic brackets bonded to two different all-ceramic crowns, IPS Empress 2 and In-Ceram Alumina, to compare the SBS between hydrofluoric acid (HFA), phosphoric acid etched, and sandblasted, non-etched all-ceramic surfaces. Ninety-six all-ceramic crowns were fabricated resembling a maxillary left first premolar. The crowns were divided into eight groups: (1) metal brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (2) metal brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (3) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (4) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (5) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched IPS Empress 2 crowns; (6) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched In-Ceram crowns; (7) metal brackets bonded to sandblasted, non-etched IPS Empress 2 crowns; and (8) metal brackets bonded to sandblasted, non-etched In-Ceram crowns. Metal and ceramic orthodontic brackets were bonded using a conventional light polymerizing adhesive resin. An Instron universal testing machine was used to determine the SBS at a crosshead speed of 0.1 mm/minute. Comparison between groups was performed using a univariate general linear model and chi-squared tests. The highest mean SBS was found in group 3 (120.15 +/- 45.05 N) and the lowest in group 8 (57.86 +/- 26.20 N). Of all the variables studied, surface treatment was the only factor that significantly affected SBS (P < 0.001). Acid etch application to sandblasted surfaces significantly increased the SBS in groups 1, 2, 5, and 6. The SBS of metal brackets debonded from groups 1, 3, and 5 were not significantly different from those of groups 2, 4, and 6. All debonded metal brackets revealed a similar pattern of bond failure at the adhesive-restorative interface. However, ceramic brackets had a significantly different adhesive failure pattern with dominant failure at the adhesive-bracket interface. Ceramic fractures after bracket removal were found more often in groups 1-4. No significant difference in ceramic fracture was observed between the IPS Empress 2 and In-Ceram groups.

  12. RSRM nozzle actuator bracket/lug fracture mechanics qualification test

    NASA Technical Reports Server (NTRS)

    Kelley, Peggy

    1993-01-01

    This is the final report for the actuator bracket/lug fracture mechanics qualification test. The test plan (CTP-0071) outlined a two-phase test program designed to answer questions about the fracture criticality of the redesigned solid rocket motor (RSRM) nozzle actuator bracket. An analysis conducted using the NASA/FLAGRO fracture mechanics computer program indicated that the actuator bracket might be a fracture critical component. In the NASA/FLAGRO analysis, a simple lug model was used to represent the actuator bracket. It was calculated that the bracket would fracture if subjected to an actuator stall load in the presence of a 0.10 in. corner crack at the actuator attachment hole. The 0.10 in. crack size corresponds to the nondestructive inspection detectability limit for the actuator bracket. The inspection method used is the dye penetrant method. The actuator stall load (103,424 lb) is the maximum load which the actuator bracket is required to withstand during motor operation. This testing was designed to establish the accuracy of the analytical model and to directly determine whether the actuator bracket is capable of meeting fracture mechanics safe-life requirements.

  13. [Effects of different resin removal methods on shear bond strength of rebonded orthodontic brackets].

    PubMed

    Wu, Hai-miao; Zhao, Bin-jiao; Chen, Dong

    2015-06-01

    To compare the shear bond strength (SBS) of rebonded orthodontic metal brackets with different resin removal methods. Forty extracted premolars were chosen as samples and divided into 4 experimental groups. The teeth were bonded with brackets. The brackets from 3 groups were debonded while adhesive remnants were removed from bracket bases by methods of grinding, sandblasting, and direct flaming, respectively and then rebonded. The SBS values of all rebonded brackets were determined after pH cycling experiment for 30 days. Some rebonded bracket bases were selected and observed under scanning electron microscope (SEM). The data was analyzed by one-way ANOVA test using SPSS 13.0 software package. Statistical analysis revealed a significant difference of SBS values among the 4 experimental groups (P<0.05). The SBS values of the group by direct flaming was significantly lower compared to the other groups (P<0.05). There was no significant difference of SBS values among the other groups. The rebonded brackets after resin removal by grinding and sandblasting have a similar SBS compared to the initial brackets adhesive.

  14. In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets.

    PubMed

    Kim, Joo Hyoung; Cha, Jung Yul; Hwang, Chung Ju

    2012-12-01

    This in vitro study was undertaken to evaluate the physical, chemical, and biological properties of commercially available metal orthodontic brackets in South Korea, because national standards for these products are lacking. FOUR BRACKET BRANDS WERE TESTED FOR DIMENSIONAL ACCURACY, (MANUFACTURING ERRORS IN ANGULATION AND TORQUE), CYTOTOXICITY, COMPOSITION, ELUTION, AND CORROSION: Archist (Daeseung Medical), Victory (3M Unitek), Kosaka (Tomy), and Confidence (Shinye Odontology Materials). The tested rackets showed no significant differences in manufacturing errors in angulation, but Confidence brackets showed a significant difference in manufacturing errors in torque. None of the brackets were cytotoxic to mouse fibroblasts. The metal ion components did not show a regular increasing or decreasing trend of elution over time, but the volume of the total eluted metal ions increased: Archist brackets had the maximal Cr elution and Confidence brackets appeared to have the largest volume of total eluted metal ions because of excessive Ni elution. Confidence brackets showed the lowest corrosion resistance during potentiodynamic polarization. The results of this study could potentially be applied in establishing national standards for metal orthodontic brackets and in evaluating commercially available products.

  15. [Friction: self-ligating brackets].

    PubMed

    Thermac, Guilhem; Morgon, Laurent; Godeneche, Julien

    2008-12-01

    The manufacturers of self-ligating brackets advertise a reduction of the friction engendered between the wire and the bracket, which is an essential parameter for treatment's speed and comfort. We have compared the friction obtained with four types of self-ligating brackets - In-Ovation R, Damon 3, Smart Clip and Quick - with that of a standard bracket Omniarch associated with an elastomeric ligature. All bracket were tested on a bench of traction with three types of wires: steel .019"x.025", TMA .019"x.025" and NEO sentalloy F300 .020"x.020". The results confirm a clear friction reduction for all tested wire.

  16. Torsional strength of computer-aided design/computer-aided manufacturing-fabricated esthetic orthodontic brackets.

    PubMed

    Alrejaye, Najla; Pober, Richard; Giordano Ii, Russell

    2017-01-01

    To fabricate orthodontic brackets from esthetic materials and determine their fracture resistance during archwire torsion. Computer-aided design/computer-aided manufacturing technology (Cerec inLab, Sirona) was used to mill brackets with a 0.018 × 0.025-inch slot. Materials used were Paradigm MZ100 and Lava Ultimate resin composite (3M ESPE), Mark II feldspathic porcelain (Vita Zahnfabrik), and In-Ceram YZ zirconia (Vita Zahnfabrik). Ten brackets of each material were subjected to torque by a 0.018 × 0.025-inch stainless steel archwire (G&H) using a specially designed apparatus. The average moments and degrees of torsion necessary to fracture the brackets were determined and compared with those of commercially available alumina brackets, Mystique MB (Dentsply GAC). The YZ brackets were statistically significantly stronger than any other tested material in their resistance to torsion (P < .05). The mean torques at failure ranged from 3467 g.mm for Mark II to 11,902 g.mm for YZ. The mean torsion angles at failure ranged from 15.3° to 40.9°. Zirconia had the highest torsional strength among the tested esthetic brackets. Resistance of MZ100 and Lava Ultimate composite resin brackets to archwire torsion was comparable to commercially available alumina ceramic brackets.

  17. Cleansing orthodontic brackets with air-powder polishing: effects on frictional force and degree of debris.

    PubMed

    Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David

    2016-01-01

    Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p < 0.05. Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p < 0.01). Image analysis showed that the control group exhibited greater debris buildup (median = 2.0) compared with the group that received prophylaxis with air-powder polishing (median = 0.5) (p < 0.05). Cleansing orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.

  18. Biodegradation of orthodontic metallic brackets and associated implications for friction.

    PubMed

    Regis, Saulo; Soares, Paulo; Camargo, Elisa S; Guariza Filho, Odilon; Tanaka, Orlando; Maruo, Hiroshi

    2011-10-01

    This study aimed to assess the effect of clinical exposure on the surface morphology, dimensions, and frictional behavior of metallic orthodontic brackets. Ninety-five brackets, of 3 commercial brands, were retrieved from patients who had finished orthodontic treatment. As-received brackets, matched by type and brand, were used for comparisons. Surface morphology and precipitated material were analyzed by optical and scanning electron microscopy and x-ray microanalysis. Bracket dimensions were measured with a measuring microscope. Resistance to sliding on a stainless steel wire was assessed. Retrieved brackets showed surface alterations from corrosion, wear, and plastic deformation, especially in the external slot edges. Film deposition over the alloy surface was observed to a variable extent. The main elements in the film were carbon, oxygen, calcium, and phosphorus. The as-received brackets showed differences (P <0.05) in the slot sizes among brands, and 1 brand showed a 3% increase in the retrieved brackets' slots. The frictional behavior differed among brands. Retrieved brackets of 2 brands showed 10% to 20% increases in resistance to sliding. Metallic brackets undergo significant degradation during orthodontic treatment, possibly with increased friction. At present, it is difficult to predict the impact of these changes on the clinical performance of orthodontic components. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. Metallurgical characterization of orthodontic brackets produced by Metal Injection Molding (MIM).

    PubMed

    Zinelis, Spiros; Annousaki, Olga; Makou, Margarita; Eliades, Theodore

    2005-11-01

    The aim of this study was to investigate the bonding base surface morphology, alloy type, microstructure, and hardness of four types of orthodontic brackets produced by Metal Injection Molding technology (Discovery, Extremo, Freedom, and Topic). The bonding base morphology of the brackets was evaluated by scanning electron microscopy (SEM). Brackets from each manufacturer were embedded in epoxy resin, and after metallographic grinding, polishing and coating were analyzed by x-ray energy-dispersive spectroscopic (EDS) microanalysis to assess their elemental composition. Then, the brackets were subjected to metallographic etching to reveal their metallurgical structure. The same specimen surfaces were repolished and used for Vickers microhardness measurements. The results were statistically analyzed with one-way analysis of variance and Student-Newman-Keuls multiple comparison test at the 0.05 level of significance. The findings of SEM observations showed a great variability in the base morphology design among the brackets tested. The x-ray EDS analysis demonstrated that each bracket was manufactured from different ferrous or Co-based alloys. Metallographic analysis showed the presence of a large grain size for the Discovery, Freedom, and Topic brackets and a much finer grain size for the Extremo bracket. Vickers hardness showed great variations among the brackets (Topic: 287 +/- 16, Freedom: 248 +/- 13, Discovery: 214 +/- 12, and Extremo: 154 +/- 9). The results of this study showed that there are significant differences in the base morphology, composition, microstructure, and microhardness among the brackets tested, which may anticipate significant clinical implications.

  20. Translucency and color match with a shade guide of esthetic brackets with the aid of a spectroradiometer.

    PubMed

    Lee, Yong-Keun; Bin, Yu

    2016-01-01

    Since the color of esthetic brackets should match that of teeth, the aims of this study were to determine the color and translucency of esthetic brackets by means of the clinically relevant use of a spectroradiometer, and to compare the color of brackets with that of a commercial shade guide. The color of central and tie-wing regions of four plastic and four ceramic brackets was measured according to the CIE L*a*b* color scale over white and black backgrounds. Brackets were classified into five groups based on their composition. The color of Vitapan Classical Shade Guide tabs was also measured. Translucency parameter (TP) and contrast ratio (CR) were calculated to determine translucency. Color differences between brackets and the shade guide tabs were 10.4 - 34.5 ∆E*ab units. TP and CR values for the central region were 16.4 - 27.7 and 0.38 - 0.58, whereas for the tie-wings they were 24.0 - 39.9 and 0.25 - 0.45, respectively. The color coordinates, TP and CR values were significantly influenced by bracket composition and brand (p < 0.05). Esthetic brackets investigated herein showed unacceptable color differences (∆E*ab > 5.5) compared with the shade guide tabs. Differences in the translucency of brackets by brand were within the visually perceptible range (∆CR > 0.07). Therefore, brackets showing the best matching performance for each case should be selected considering esthetic and functional demands.

  1. Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations.

    PubMed

    Nucera, Riccardo; Gatto, Elda; Borsellino, Chiara; Aceto, Pasquale; Fabiano, Francesca; Matarese, Giovanni; Perillo, Letizia; Cordasco, Giancarlo

    2014-05-01

    To evaluate how different bracket-slot design characteristics affect the forces released by superelastic nickel-titanium (NiTi) alignment wires at different amounts of wire deflection. A three-bracket bending and a classic-three point bending testing apparatus were used to investigate the load-deflection properties of one superelastic 0.014-inch NiTi alignment wire in different experimental conditions. The selected NiTi archwire was tested in association with three bracket systems: (1) conventional twin brackets with a 0.018-inch slot, (2) a self-ligating bracket with a 0.018-inch slot, and (3) a self-ligating bracket with a 0.022-inch slot. Wire specimens were deflected at 2 mm and 4 mm. Use of a 0.018-inch slot bracket system, in comparison with use of a 0.022-inch system, increases the force exerted by the superelastic NiTi wires at a 2-mm deflection. Use of a self-ligating bracket system increases the force released by NiTi wires in comparison with the conventional ligated bracket system. NiTi wires deflected to a different maximum deflection (2 mm and 4 mm) release different forces at the same unloading data point (1.5 mm). Bracket design, type of experimental test, and amount of wire deflection significantly affected the amount of forces released by superelastic NiTi wires (P<.05). This phenomenon offers clinicians the possibility to manipulate the wire's load during alignment.

  2. Sensitivity of titanium brackets to the corrosive influence of fluoride-containing toothpaste and tea.

    PubMed

    Harzer, W; Schröter, A; Gedrange, T; Muschter, F

    2001-08-01

    Titanium brackets are used in orthodontic patients with an allergy to nickel and other specific substances. In recent studies, the corrosive properties of fluoride-containing toothpastes with different pH values were investigated. The present in vivo study tested how the surfaces of titanium brackets react to the corrosive influence of acidic fluoride-containing toothpaste during orthodontic treatment. Molar bands were placed on 18 orthodontic patients. In these same patients, titanium brackets were bonded on the left quadrants and stainless steel brackets on the right quadrants of the upper and lower arches. Fifteen patients used Gel Kam containing soluble tin fluoride (pH 3.2), whereas 3 used fluoride-free toothpaste. The brackets were removed for evaluation by light microscopy and scanning microscopy 5.5 to 7.0 months and 7.5 to 17 months after bonding. The quality and quantity of elements present were measured by scanning microscopy. Macroscopic evaluation showed the matte gray color of titanium brackets dominating over the silver gleam of the steel brackets. The plaque accumulation on titanium brackets is high because of the very rough surface. Pitting and crevices were observed in only 3 of the 165 brackets tested. The present in vivo investigation confirms the results of in vitro studies, but the changes are so minor that titanium brackets can safely be used for up to 18 months. Wing surfaces should be improved by modifying the manufacturing process.

  3. A 12 month clinical study of bond failures of recycled versus new stainless steel orthodontic brackets.

    PubMed

    Cacciafesta, Vittorio; Sfondrini, Maria Francesca; Melsen, Birte; Scribante, Andrea

    2004-08-01

    The purpose of this prospective longitudinal randomized study was to compare the clinical performance of recycled brackets with that of new stainless steel brackets (Orthos). Twenty patients treated with fixed appliances were included in the investigation. Using a 'split-mouth' design, the dentition of each patient was divided into four quadrants. In 11 randomly selected patients, the maxillary left and mandibular right quadrants were bonded with recycled brackets, and the remaining quadrants with new stainless steel brackets. In the other nine patients the quadrants were inverted. Three hundred and ten stainless steel brackets were examined: 156 were recycled and the remaining 154 were new. All the brackets were bonded with a self-cured resin-modified glass ionomer (GC Fuji Ortho). The number, cause, and date of bracket failures were recorded over 12 months. Statistical analysis was performed by means of a paired t-test, Kaplan-Meier survival estimates, and the log-rank test. No statistically significant differences were found between: (a) the total bond failure rate of recycled and new stainless steel brackets; (b) the upper and lower arches; (c) the anterior and posterior segments. These findings demonstrate that recycling metallic orthodontic brackets can be of benefit to the profession, both economically and ecologically, as long as the orthodontist is aware of the various aspects of the recycling methods, and that patients are informed about the type of bracket that will be used for their treatment.

  4. Children's note taking as a mnemonic tool.

    PubMed

    Eskritt, Michelle; McLeod, Kellie

    2008-09-01

    When given the opportunity to take notes in memory tasks, children sometimes make notes that are not useful. The current study examined the role that task constraints might play in the production of nonmnemonic notes. In Experiment 1, children played one easy and one difficult memory game twice, once with the opportunity to make notes and once without that opportunity. More children produced functional notations for the easier task than for the more difficult task, and their notations were beneficial to memory performance. Experiment 2 found that the majority of children who at first made nonmnemonic notations were able to produce functional notations with minimal training, and there was no significant difference in notation quality or memory performance between spontaneous and trained note takers. Experiment 3 revealed that the majority of children could transfer their training to a novel task. The results suggest that children's production of nonmnemonic notes may be due in part to a lack of knowledge regarding what task information is important to represent or how to represent it in their notes rather than to an inability to make functional notes in general.

  5. Surface morphology and electrical properties of Au/Ni/ Left-Pointing-Angle-Bracket C Right-Pointing-Angle-Bracket /n-Ga{sub 2}O{sub 3}/p-GaSe Left-Pointing-Angle-Bracket KNO{sub 3} Right-Pointing-Angle-Bracket hybrid structures fabricated on the basis of a layered semiconductor with nanoscale ferroelectric inclusions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakhtinov, A. P., E-mail: chimsp@ukrpost.ua; Vodopyanov, V. N.; Netyaga, V. V.

    2012-03-15

    Features of the formation of Au/Ni/ Left-Pointing-Angle-Bracket C Right-Pointing-Angle-Bracket /n-Ga{sub 2}O{sub 3} hybrid nanostructures on a Van der Waals surface (0001) of 'layered semiconductor-ferroelectric' composite nanostructures (p-GaSe Left-Pointing-Angle-Bracket KNO{sub 3} Right-Pointing-Angle-Bracket ) are studied using atomic-force microscopy. The room-temperature current-voltage characteristics and the dependence of the impedance spectrum of hybrid structures on a bias voltage are studied. The current-voltage characteristic includes a resonance peak and a portion with negative differential resistance. The current attains a maximum at a certain bias voltage, when electric polarization switching in nanoscale three-dimensional inclusions in the layered GaSe matrix occurs. In the high-frequency region (fmore » > 10{sup 6} Hz), inductive-type impedance (a large negative capacitance of structures, {approx}10{sup 6} F/mm{sup 2}) is detected. This effect is due to spinpolarized electron transport in a series of interconnected semiconductor composite nanostructures with multiple p-GaSe Left-Pointing-Angle-Bracket KNO{sub 3} Right-Pointing-Angle-Bracket quantum wells and a forward-biased 'ferromagnetic metal-semiconductor' polarizer (Au/Ni/ Left-Pointing-Angle-Bracket C Right-Pointing-Angle-Bracket /n{sup +}-Ga{sub 2}O{sub 3}/n-Ga{sub 2}O{sub 3}). A shift of the maximum (current hysteresis) is detected in the current-voltage characteristics for various directions of the variations in bias voltage.« less

  6. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    PubMed Central

    Behroozian, Ahmad; Kachoei, Mojgan; Khatamian, Masumeh; Divband, Baharak

    2016-01-01

    Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO). Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS) orthodonticwires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnOnanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electronmicroscope) evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wiresand brackets in four groups: group ZZ (coated wire and bracket), group OO (uncoated wire and bracket), group ZO (coatedwire and uncoated bracket) and group OZ (uncoated wire and coated bracket). Kolmogorov-Smirnov, Mann-Whitney andKruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N) was the highest (P <0.05), and OZ (2.18±0.5 N) had the lowest amount of friction (P <0.05) among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively). Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique,and wire coating combined with bracket coating is not recommended due to its effect on friction. PMID:27429727

  7. Suitability of orthodontic brackets for rebonding and reworking following removal by air pressure pulses and conventional debracketing techniques.

    PubMed

    Knösel, Michael; Mattysek, Simone; Jung, Klaus; Kubein-Meesenburg, Dietmar; Sadat-Khonsari, Reza; Ziebolz, Dirk

    2010-07-01

    To test the null hypothesis that there are no significant differences in the reusability of debonded brackets with regard to debonding technique and adhesive used. Ninety-six osteotomed third molars were randomly assigned to two study groups (n = 48) for bonding of a 0.018-inch bracket (Ormesh, Ormco) with either a composite adhesive (Mono-Lok2; RMO) or a glass ionomer cement (GIC; Fuji Ortho LC;GC). Each of these two groups were then randomly divided into four subgroups (n = 12) according to the method of debonding using (1) bracket removal pliers (BRP; Dentaurum), (2) a side cutter (SC; Dentaurum), (3) a lift-off debracketing instrument (LODI; 3M-Unitek), or (4) an air pressure pulse device (CoronaFlex; KaVo). The brackets were subsequently assessed visually for reusability and reworkability with 2x magnification and by pull testing with a 0.017- x 0.025-inch steel archwire. The proportions of reusable brackets were individually compared in terms of mode of removal and with regard to adhesives using the Fisher exact test (alpha = 5%). The null hypothesis was rejected. Not taking into account the debonding method, brackets bonded with GIC were judged to a significant extent (81%; n = 39; P < .01) to be reworkable compared with those bonded with composite (56%; n = 27). All brackets in both adhesive groups removed with either the LODI or the CoronaFlex were found to be reusable, whereas 79% (46%) of the brackets removed with the BRP (SC) were not. The proportion of reusable brackets differed significantly between modes of removal (P < .01). With regard to bracket reusability, the SC and the BRP cannot be recommended for debonding brackets, especially in combination with a composite adhesive.

  8. SBS vs Inhouse Recycling Methods-An Invitro Evaluation

    PubMed Central

    Verma, Jaya Krishanan; Arun; Sundari, Shanta; Chandrasekhar, Shyamala; Kumar, Aravind

    2015-01-01

    Introduction In today’s world of economic crisis it is not feasible for an orthodontist to replace each and every debonded bracket with a new bracket- quest for an alternative thrives Orthodontist. The concept of recycling bracket for its reuse has evolved over a period of time. Orthodontist can send the brackets to various commercial recycling companies for recycling, but it’s impractical as these are complex procedures and require time and usage of a new bracket would seem more feasible. Thereby, in-house methods have been developed. The aim of the study was to determine the SBS (Shear Bond Strength) and to compare, evaluate the efficiency of in house recycling methods with that of the SBS of new brackets. Materials and Methods Five in–house-recycling procedures-Adhesive Grinding Method, Sandblasting Method, Thermal Flaming Method, Buchman method and Acid Bath Method were used in the present study. Initial part of the study included the use of UV/Vis spectrophotometer where in the absorption level of base of new stainless steel bracket is compared with the base of a recycled bracket. The difference seen in the UV absorbance can be attributed to the presence of adhesive remnant. For each recycling procedure the difference in UV absorption is calculated. New stainless steel brackets and recycled brackets were tested for its shear bond strength with Instron testing machine. Comparisons were made between shear bond strength of new brackets with that of recycled brackets. The last part of the study involved correlating the findings of UV/Vis spectrophotometer with the shear bond strength for each recycling procedure. Results Among the recycled brackets the Sandblasting technique showed the highest shear bond strength (19.789MPa) and the least was shown by the Adhesive Grinding method (13.809MPa). Conclusion The study concludes that sand blasting can be an effective choice among the 5 in house methods of recycling methods. PMID:26501002

  9. Comparative Evaluation of Friction Resistance of Titanium, Stainless Steel, Ceramic and Ceramic with Metal Insert Brackets with Varying Dimensions of Stainless Steel Wire: An In vitro Multi-center Study.

    PubMed

    Kumar, B Sunil; Miryala, Suresh; Kumar, K Kiran; Shameem, K; Regalla, Ravindra Reddy

    2014-09-01

    The orthodontist seeks an archwire-bracket combination that has both good biocompatibility and low friction. Hence, the aim of this multicenter in vitro study was to evaluate and compare the frictional resistance generated between titanium (Ti), stainless steel (SS), ceramic and ceramic with metal insert (CMI) brackets with SS wires of varying dimensions in a specially designed apparatus. The material used in this study were Ti, SS, Ceramic and CMI with 0.018″ slot manufactured with zero degree tip and -7° torque premolar brackets (3M, Unitek) and SS wires of varying dimensions (0.016″ round, 0.016 × 0.016″ square, 0.016 × 0.022″ rectangular and 0.017 × 0.025″ rectangular) used. The frictional resistance was measured using Instron Universal testing machine (Model no. 4301). The specimen population in each center composed each of 160 brackets and wires. Differences among the all bracket/wire combinations were tested using (one-way) ANOVA, followed by the student Newman Keuls multiple comparisons of means ranking (at P < 0.05) for the determination of differences among the groups. Ti bracket in combination with 0.017 × 0.025″ SS rectangular wire produced significant force levels for an optimum orthodontic movement with least frictional resistance. Ti brackets have least resistance and rectangular wires produced significant force. These can be used to avoid hazards of Nickel. SS brackets revealed higher static frictional force values as the wire dimension increased and showed lower static friction than Ti brackets for all wires except the thicker wire. Our study recommends the preclusion of brackets with rough surface texture (Ti brackets) with SS ligature wire for ligating bracket and archwire are better to reduce friction.

  10. Torque expression of 0.018 and 0.022 inch conventional brackets.

    PubMed

    Sifakakis, Iosif; Pandis, Nikolaos; Makou, Margarita; Eliades, Theodore; Katsaros, Christos; Bourauel, Christoph

    2013-10-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

  11. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets.

    PubMed

    Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore de

    2016-01-01

    The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  12. Adhesion of mutans streptococci to self-ligating ceramic brackets: in vivo quantitative analysis with real-time polymerase chain reaction.

    PubMed

    Jung, Woo-Sun; Yang, Il-Hyung; Lim, Won Hee; Baek, Seung-Hak; Kim, Tae-Woo; Ahn, Sug-Joon

    2015-12-01

    To analyze in vivo mutans streptococci (MS) adhesion to self-ligating ceramic brackets [Clarity-SL (CSL) and Clippy-C (CC)] and the relationships between bacterial adhesion and oral hygiene indices. Four central incisor brackets from the maxilla and mandible were collected from 40 patients (20 patients per each bracket type) at debonding immediately after plaque and gingival indices were measured. Adhesions of Streptococcus mutans, S. sobrinus, and total bacteria were quantitatively determined using real-time polymerase chain reaction after genomic DNA was extracted. Factorial analysis of variance was used to analyze bacterial adhesion to the brackets with respect to the bracket type and jaw position. Correlation coefficients were calculated to determine the relationships of bacterial adhesion to oral hygiene indices. Adhesion of total bacteria and S. mutans to CSL was higher than that to CC (P < 0.001). Adhesion of total bacteria to the mandibular brackets was higher than that to the maxillary ones (P < 0.001), while adhesion of S. mutans to the maxillary brackets were higher than that in the mandibular ones (P < 0.001). In particular, the proportion of S. mutans to total bacteria in CSL was higher than CC (P < 0.05) in the maxillary anterior teeth (P < 0.001). There were no significant differences in adhesion of S. sobrinus between the brackets and jaw positions. Interestingly, no significant relationships were found between bacterial adhesions and oral hygiene indices. Complex bracket configurations may significantly influence bacterial adhesion to orthodontic brackets. Further in vivo study using bracket raw materials will help to define the relationships between bacteria adhesion and enamel demineralization. Because oral hygiene indices were not significantly correlated with adhesions of MS to self-ligating ceramic brackets, careful examinations around the brackets should be needed to prevent enamel demineralization, regardless of oral hygiene status. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  13. In vitro evaluation of microbial contamination of orthodontic brackets as received from the manufacturer using microbiological and molecular tests.

    PubMed

    Dos Santos Gerzson, Darlene R; Simon, Daniel; Dos Anjos, Aline Lima; Freitas, Maria Perpétua Mota

    2015-11-01

    To test the null hypothesis that orthodontic brackets as supplied by manufacturers do not have microbial contamination. The sample comprised 140 brackets of four different commercially available brands, used directly from the manufacturer's packaging, divided into 14 groups (n  =  10 brackets each). Of the 140 pieces, 60 were full cases and 80 were replacement brackets. Materials were tested to detect bacterial growth, analyze types of bacteria present (biochemical test), and identify bacteria (molecular test with polymerase chain reaction [PCR]). In two of 12 groups the brackets showed microbial contamination: group 1, Morelli full case brackets, and group 12, Abzil-3M Unitek replacement brackets. Staphylococcus aureus and Staphylococcus epidermidis were the bacteria identified in groups 1 and 12, respectively (suggested by the biochemical test and confirmed by PCR). Brackets of two brands (Morelli and Abzil-3M Unitek) were found to be contaminated by bacteria in the original packages supplied by the manufacturers, which suggests a risk for patient contamination. These data suggest that the manufacturers of these materials should improve the quality control of the packaging used, including sterilization, for the security of patient health.

  14. Tiedown Bracket

    NASA Technical Reports Server (NTRS)

    Mashburn, D.; Wald, J. E.; Helmsin, F. K.

    1982-01-01

    Tiedown bracket secured to concrete slab with lag anchor and lag bolt. A trailer or other heavy equipment can be anchored by tethering it to strapping bolt. When bracket is no longer needed, it can be removed, leaving behind only lag anchor. Bracket is easily installed and removed without damage to concrete slab.

  15. The influence of bracket design on frictional losses in the bracket/arch wire system.

    PubMed

    Schumacher, H A; Bourauel, C; Drescher, D

    1999-01-01

    In arch guided tooth movement, the essential role played by bracket configuration with respect to sliding friction has been recognized by the manufacturers, a fact which has had an increasing impact on the design and marketing of new bracket models in recent years. The aim of the present in-vitro study was to investigate the influence of different bracket designs on sliding mechanics. Five differently shaped stainless steel brackets (Discovery: Dentaurum, Damon SL: A-Company, Synergy: Rocky Mountain Orthodontics, Viazis bracket and Omni Arch appliance: GAC) were compared in the 0.022"-slot system. The Orthodontic Measurement and Simulation System (OMSS) was used to quantify the difference between applied force (NiTi coil spring, 1.0 N) and orthodontically effective force and to determine leveling losses occurring during the sliding process in arch guided tooth movement. Simulated canine retraction was performed using continuous arch wires with the dimensions 0.019" x 0.025" (Standard Steel, Unitek) and 0.020" x 0.020" (Ideal Gold, GAC). Comparison of the brackets revealed friction-induced losses ranging from 20 to 70%, with clear-cut advantages resulting from the newly developed bracket types. However, an increased tendency towards leveling losses in terms of distal rotation (maximum 15 degrees) or buccal root torque (maximum 20 degrees) was recorded, especially with those brackets giving the arch wire increased mobility due to their shaping or lack of ligature wire.

  16. Influence of fibre and filler reinforcement of plastic brackets: an in vitro study.

    PubMed

    Faltermeier, Andreas; Rosentritt, Martin; Faltermeier, Rupert; Müssig, Dieter

    2007-06-01

    In spite of their popularity in fulfilling aesthetic requirements, plastic brackets still present some disadvantages because of their low elastic modulus, decreased fracture toughness, and reduced wear resistance. Fibre-reinforced composites are well established in dentistry and consist of a polymer matrix in which reinforcing fibres are embedded. Stress is transferred from the polymer matrix to the fibres which present a high tensile strength. Hence, the mechanical properties of polymers could be improved. The purpose of this study was to compare fracture strength, fracture toughness and flexural strength of an experimental fibre-reinforced bracket material, an SiO(2) filler-reinforced bracket and an unfilled plastic bracket material (control group). Experimental brackets and specialized bars were manufactured. Tests were performed after thermal cycling (5 degrees C/55 degrees C) the samples in an artificial oral environment of a device to simulate mastication. Statistical evaluation was undertaken. The median, 25th and 75th percentiles were calculated and a Mann-Whitney U-test was performed. In this study two findings were obvious. (1) Filler reinforcement of plastic brackets improved fracture strength and fracture toughness in comparison with the unfilled bracket material. (2) Glass fibre reinforcement of orthodontic bracket materials resulted in the greatest enhancement of the mechanical properties in comparison with the other test groups. Therefore, the application of glass fibres in plastic brackets is a successful method to enhance fracture strength.

  17. Comparison surface characteristics and chemical composition of conventional metallic and nickel-free brackets.

    PubMed

    Shintcovsk, Ricardo Lima; Knop, Luegya Amorim Henriques; Gandini, Luiz Gonzaga; Martins, Lidia Parsekian; Pires, Aline Segatto

    2015-01-01

    This study aims at comparing conventional and nickel-free metal bracket surface characteristics with elemental composition by scanning electron microscopy (SEM), using energy dispersive spectroscopy (EDS). The sample consisted of 40 lower incisor brackets divided into four groups: ABZ = conventional brackets, Kirium Abzil 3M® (n = 10); RL = conventional brackets, Roth Light Morelli® (n = 10); NF = nickel-free brackets, Nickel-Free Morelli® (n = 10); and RM = nickel-free brackets, Roth Max Morelli® (n = 10). Qualitative evaluation of the bracket surface was performed using SEM, whereby surface features were described and compared. The elemental composition was analyzed by EDS. According to surface analysis, groups ABZ and RL showed a homogeneous surface, with better finishing, whereas the surfaces in groups NF and RM were rougher. The chemical components with the highest percentage were Fe, Cr and C. Groups NF and MR showed no nickel in their composition. In conclusion, the bracket surface of the ABZ and RL groups was more homogeneous, with grooves and pores, whereas the surfaces in groups NF and RM showed numerous flaws, cracks, pores and grooves. The chemical composition analysis confirmed that the nickel-free brackets had no Ni in their composition, as confirmed by the manufacturer's specifications, and were therefore safe to use in patients with a medical history of allergy to this metal.

  18. Intraoral corrosion of self-ligating metallic brackets and archwires and the effect on friction

    NASA Astrophysics Data System (ADS)

    Tima, Lori Lynn

    The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). New materials were as-received from the manufacturer, and used materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p>0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface.

  19. Antimicrobial action of chlorhexidine digluconate in self-ligating and conventional metal brackets infected with Streptococcus mutans biofilm.

    PubMed

    Dias, Ana Paula; Paschoal, Marco Aurélio Benini; Diniz, Rafael Soares; Lage, Lucas Meneses; Gonçalves, Letícia Machado

    2018-01-01

    The objectives of this study were to assess the adherence of Streptococcus mutans biofilms grown over conventional ligature (CL) or self-ligating (SL) metal brackets and their bacterial viability after 0.12% chlorhexidine (CHX) digluconate treatment. The sample consisted of 48 metallic orthodontic brackets divided randomly into two groups: CL (n=24) and SL brackets (n=24). S. mutans biofilms were grown over the bracket surface (96 h) and treated with CHX (positive control) or 0.9% phosphate-buffered saline (PBS) (negative control) for 1 min each. Quantitative analysis was assessed by colony-forming units, and fluorescence microscopy was performed aiming to illustrate the outcomes. The tests were done in triplicate at three different times (n=9). Data were analyzed using ANOVA and Tukey test ( P <0.05). There were significant differences in brackets' biofilm formation, being CL largely colonized compared with SL, which was observed by colony-forming unit counting ( P <0.05) and microcopy images. Significant reduction in the viability of S. mutans was found in both brackets treated with CHX compared to PBS ( P <0.05). The antimicrobial activities of CHX were similar for CL and SL brackets ( P >0.05). In conclusion, a lower colonization was achieved in SL brackets and S. mutans biofilms were susceptible to CHX treatment to both studied brackets.

  20. Effects of sandblasting and silica coating on the bond strength of rebonded mechanically retentive ceramic brackets.

    PubMed

    Toroglu, M Serdar; Yaylali, Sirin

    2008-08-01

    The aim of this study was to determine the bond strength of rebonded mechanically retentive ceramic brackets after treatment with 2 abrasive techniques. In addition to a group of new brackets, 3 groups were treated according to the following conditions of debonded ceramic bracket bases: sandblasting, sandblasting + silane, and silica coating + silane (15 in each group). Treated ceramic brackets were rebonded on premolars. The samples were stored in distilled deionized water for 24 hours at 37 degrees C in an incubator and then thermocycled for 1000 times between 5 degrees C and 55 degrees C. Shear force was applied to the enamel-adhesive interface until debonding. The highest bond strength values were in the silica coating + silane and the new bracket groups (12.7 and 12.0 MPa, respectively), followed by the sandblasting + silane group (10.5 MPa). The sandblasting group had a significantly lower bond strength value (4.5 MPa). No enamel fracture was noted in any sample tested. In the new bracket and the sandblasting + silane groups, 20% of the samples had adhesive remnant index scores of 2, and 80% had scores of 3. In the sandblasting group, all specimens debonded at the bracket-adhesive interface. The silica coating + silane group showed mixed failures. Sandblasting + silane and silica coating + silane applications on debonded ceramic bracket base can produce bond strengths comparable with new brackets.

  1. Hallucinations of musical notation.

    PubMed

    Sacks, Oliver

    2013-07-01

    Hallucinations of musical notation may occur in a variety of conditions, including Charles Bonnet syndrome, Parkinson's disease, fever, intoxications, hypnagogic and hypnopompic states. Eight cases are described here, and their possible cerebral mechanisms discussed.

  2. The effect of various adhesives, enamel etching, and base treatment on the failure frequency of customized lingual brackets: a randomized clinical trial.

    PubMed

    Mavreas, Dimitrios; Cuzin, Jean-François; Boonen, Guillaume; Vande Vannet, Bart

    2018-05-25

    The aim of this paper was to compare failure differences in precious metal customized lingual brackets bonded with three adhesive systems. Also, differences in failure of non-precious metal brackets with and without a silicatized base layer bonded with the same adhesive, as well as the influence of enamel etching prior to using a self-etching dual cure resin were explored. Five different groups were defined in a semi-randomized approach. Group 1 (IME): Maxcem Elite with 378 Incognito brackets and etched teeth, Group 2 (IMNE): Maxcem Elite with 193 Incognito brackets on non-etched teeth, Group 3 (INE): Nexus+Excite with 385 Incognito brackets, Group 4 (IRE): Relyx with 162 Incognito brackets, Group 5 (HRME) and Group 6 (HNRME): Maxcem Elite with 182 Harmony brackets with silicatized and non-slicatized bases respectively. Bracket failures were recorded over a 12-month period. The number of failures during the observation period was small in the various adhesives types of groups, as well as in HRME and HNRME groups, and the comparisons among those groups were non-significant (P > 0.05). A statistically significant difference (P < 0.05) was found between the IME and IMNE groups. 1. During the first year of treatment customized lingual brackets failure frequencies (rates) are not different for the three adhesive materials tested. 2. Eliminating the etching stage when using self-etch/self-adhesive adhesives, may lead to a dramatic increase in the failure rates. 3. Silicoating of stainless steel customized lingual brackets does not seem to influence the failure of the bonds.

  3. Translucency and color match with a shade guide of esthetic brackets with the aid of a spectroradiometer

    PubMed Central

    Lee, Yong-Keun; Bin, Yu

    2016-01-01

    ABSTRACT Objective: Since the color of esthetic brackets should match that of teeth, the aims of this study were to determine the color and translucency of esthetic brackets by means of the clinically relevant use of a spectroradiometer, and to compare the color of brackets with that of a commercial shade guide. Methods: The color of central and tie-wing regions of four plastic and four ceramic brackets was measured according to the CIE L*a*b* color scale over white and black backgrounds. Brackets were classified into five groups based on their composition. The color of Vitapan Classical Shade Guide tabs was also measured. Translucency parameter (TP) and contrast ratio (CR) were calculated to determine translucency. Results: Color differences between brackets and the shade guide tabs were 10.4 - 34.5 ∆E*ab units. TP and CR values for the central region were 16.4 - 27.7 and 0.38 - 0.58, whereas for the tie-wings they were 24.0 - 39.9 and 0.25 - 0.45, respectively. The color coordinates, TP and CR values were significantly influenced by bracket composition and brand (p < 0.05). Conclusions: Esthetic brackets investigated herein showed unacceptable color differences (∆E*ab > 5.5) compared with the shade guide tabs. Differences in the translucency of brackets by brand were within the visually perceptible range (∆CR > 0.07). Therefore, brackets showing the best matching performance for each case should be selected considering esthetic and functional demands. PMID:27275619

  4. 78 FR 24985 - Airworthiness Directives; Cessna Aircraft Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-29

    ... (L-126A,B,C), 195A, and 195B airplanes that are equipped with certain inboard aileron hinge brackets... 4, 2013), currently requires you to repetitively inspect the affected inboard aileron hinge brackets... brackets. Replacement with aluminum brackets would terminate the need for the repetitive inspections...

  5. Universal Cable Brackets

    NASA Technical Reports Server (NTRS)

    Vanvalkenburgh, C.

    1985-01-01

    Concept allows routing easily changed. No custom hardware required in concept. Instead, standard brackets cut to length and installed at selected locations along cable route. If cable route is changed, brackets simply moved to new locations. Concept for "universal" cable brackets make it easy to route electrical cable around and through virtually any structure.

  6. 21 CFR 872.3750 - Bracket adhesive resin and tooth conditioner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... composed of an adhesive compound, such as polymethylmethacrylate, intended to cement an orthodontic bracket... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bracket adhesive resin and tooth conditioner. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3750 Bracket adhesive resin...

  7. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply...

  8. Using a Bracketed Analysis as a Learning Tool.

    ERIC Educational Resources Information Center

    Main, Keith

    1995-01-01

    Bracketed analysis is an examination of experiences within a defined time frame or "bracket." It assumes the ability to learn from any source: behaviors, emotions, rational and irrational thought, insights, reflections, and reactions. A bracketed analysis to determine what went wrong with a grant proposal that missed deadlines…

  9. 21 CFR 872.3750 - Bracket adhesive resin and tooth conditioner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bracket adhesive resin and tooth conditioner. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3750 Bracket adhesive resin and tooth conditioner. (a) Identification. A bracket adhesive resin and tooth conditioner is a device...

  10. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply...

  11. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply...

  12. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply...

  13. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply...

  14. 77 FR 34281 - Airworthiness Directives; Schweizer Aircraft Corporation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-11

    ... brackets, inspecting the mounting brackets for wear greater than 0.002-inch deep, and replacing the mounting bracket if the bracket wear exceeds 0.002-inch deep. [cir] Modifying the aft fuselage assembly by... areas, and replacing the spar if the wear exceeds 0.002-inch deep. [cir] Inspecting for rivet...

  15. Definition of the Neutrosophic Probability

    NASA Astrophysics Data System (ADS)

    Smarandache, Florentin

    2014-03-01

    Neutrosophic probability (or likelihood) [1995] is a particular case of the neutrosophic measure. It is an estimation of an event (different from indeterminacy) to occur, together with an estimation that some indeterminacy may occur, and the estimation that the event does not occur. The classical probability deals with fair dice, coins, roulettes, spinners, decks of cards, random works, while neutrosophic probability deals with unfair, imperfect such objects and processes. For example, if we toss a regular die on an irregular surface which has cracks, then it is possible to get the die stuck on one of its edges or vertices in a crack (indeterminate outcome). The sample space is in this case: {1, 2, 3, 4, 5, 6, indeterminacy}. So, the probability of getting, for example 1, is less than 1/6. Since there are seven outcomes. The neutrosophic probability is a generalization of the classical probability because, when the chance of determinacy of a stochastic process is zero, these two probabilities coincide. The Neutrosophic Probability that of an event A occurs is NP (A) = (ch (A) , ch (indetA) , ch (A ̲)) = (T , I , F) , where T , I , F are subsets of [0,1], and T is the chance that A occurs, denoted ch(A); I is the indeterminate chance related to A, ch(indetermA) ; and F is the chance that A does not occur, ch (A ̲) . So, NP is a generalization of the Imprecise Probability as well. If T, I, and F are crisp numbers then: - 0 <= T + I + F <=3+ . We used the same notations (T,I,F) as in neutrosophic logic and set.

  16. Integrated mobility measurement and notation system

    NASA Technical Reports Server (NTRS)

    Roebuck, J. A., Jr.

    1967-01-01

    System for description of movements and positions facilitates design of space suits with more mobility. This measurement and notation system gives concise and unequivocal descriptions, compatible with engineering analysis and applicable to specific needs.

  17. Layered Systems Engineering Engines

    NASA Technical Reports Server (NTRS)

    Breidenthal, Julian C.; Overman, Marvin J.

    2009-01-01

    A notation is described for depicting the relationships between multiple, contemporaneous systems engineering efforts undertaken within a multi-layer system-of-systems hierarchy. We combined the concepts of remoteness of activity from the end customer, depiction of activity on a timeline, and data flow to create a new kind of diagram which we call a "Layered Vee Diagram." This notation is an advance over previous notations because it is able to be simultaneously precise about activity, level of granularity, product exchanges, and timing; these advances provide systems engineering managers a significantly improved ability to express and understand the relationships between many systems engineering efforts. Using the new notation, we obtain a key insight into the relationship between project duration and the strategy selected for chaining the systems engineering effort between layers, as well as insights into the costs, opportunities, and risks associated with alternate chaining strategies.

  18. A 3D generic inverse dynamic method using wrench notation and quaternion algebra.

    PubMed

    Dumas, R; Aissaoui, R; de Guise, J A

    2004-06-01

    In the literature, conventional 3D inverse dynamic models are limited in three aspects related to inverse dynamic notation, body segment parameters and kinematic formalism. First, conventional notation yields separate computations of the forces and moments with successive coordinate system transformations. Secondly, the way conventional body segment parameters are defined is based on the assumption that the inertia tensor is principal and the centre of mass is located between the proximal and distal ends. Thirdly, the conventional kinematic formalism uses Euler or Cardanic angles that are sequence-dependent and suffer from singularities. In order to overcome these limitations, this paper presents a new generic method for inverse dynamics. This generic method is based on wrench notation for inverse dynamics, a general definition of body segment parameters and quaternion algebra for the kinematic formalism.

  19. [Comparison of Japanese Notation and Meanings among Three Terminologies in Radiological Technology Domain].

    PubMed

    Yagahara, Ayako; Tsuji, Shintaro; Hukuda, Akihisa; Nishimoto, Naoki; Ogasawara, Katsuhiko

    2016-03-01

    The purpose of this study is to investigate the differences in the notation of technical terms and their meanings among three terminologies in Japanese radiology-related societies. The three terminologies compared in this study were "radiological technology terminology" and its supplement published by the Japan Society of Radiological Technology, "medical physics terminology" published by the Japan Society of Medical Physics, and "electric radiation terminology" published by the Japan Radiological Society. Terms were entered into spreadsheets and classified into the following three categories: Japanese notation, English notation, and meanings. In the English notation, terms were matched to character strings in the three terminologies and were extracted and compared. The Japanese notations were compared among three terminologies, and the difference between the meanings of the two terminologies radiological technology terminology and electric radiation terminology were compared. There were a total of 14,982 terms in the three terminologies. In English character strings, 2,735 terms were matched to more than two terminologies, with 801 of these terms matched to all the three terminologies. Of those terms in English character strings matched to three terminologies, 752 matched to Japanese character strings. Of the terms in English character strings matched to two terminologies, 1,240 matched to Japanese character strings. With regard to the meanings category, eight terms had mismatched meanings between the two terminologies. For these terms, there were common concepts between two different meaning terms, and it was considered that the derived concepts were described based on domain.

  20. Design of a Prototype Autonomous Amphibious WHEGS(Trademark) Robot for Surf-Zone Operations

    DTIC Science & Technology

    2005-06-01

    Control Loop ........................................................................ 9 Figure 7. Physical Layout (without GPS bracket ...12 Figure 8. Side View showing GPS Bracket ........................................................ 13 Figure 9...without GPS bracket ) 13 Figure 8. Side View showing GPS Bracket 1. Body Construction The design of the robot body for this thesis was made to

  1. [Individual indirect bonding technique (IIBT) using set-up model].

    PubMed

    Kyung, H M

    1989-01-01

    There has been much progress in Edgewise Appliance since E.H. Angle. One of the most important procedures in edgewise appliance is correct bracket position. Not only conventional edgewise appliance but also straight wire appliance & lingual appliance cannot be used more effectively unless the bracket position is accurate. Improper bracket positioning may reveal much problems during treatment, especially in finishing state. It may require either rebonding after the removal of the malpositioned bracket or the greater number of arch wire and the more complex wire bending, causing much difficulty in performing effective treatments. This made me invent Individual Indirect Bonding Technique with the use of multi-purpose set-up model in order to determine a correct and objective bracket position according to individual patients. This technique is more accurate than former indirect bonding techniques in bracket positioning, because it decides the bracket position on a set-up model which has produced to have the occlusal relationship the clinician desired. This technique is especially effective in straight wire appliance and lingual appliance in which the correct bracket positioning is indispensible.

  2. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    PubMed Central

    Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; de Freitas, Karina Maria Salvatore

    2016-01-01

    ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires. PMID:27812620

  3. Bond efficacy of recycled orthodontic brackets: A comparative in vitro evaluation of two methods.

    PubMed

    Shetty, Vikram; Shekatkar, Yash; Kumbhat, Neesu; Gautam, G; Karbelkar, Shalan; Vandekar, Meghna

    2015-01-01

    Recycling of orthodontic brackets in developing orthodontic economies is an extremely common procedure. Bonding protocols and reliability of these brackets is, however, questionable, and still the subject of research. The aim was to evaluate and compare the shear bond strength of brackets recycled with sandblasting and silicoating. Ninety extracted human premolars were bonded with 0.022" SS brackets (American Orthodontics, Sheboygan USA) and then debonded. The debonded brackets were divided into three groups of 30 each. Group I: Sandblasting with 50-μm aluminum oxide (control group) Group II: Sandblasting with 50-μm aluminum oxide followed by metal primer application Group III: Silicoating with 30-μm Cojet sand followed by silane application and rebonded with Transbond XT. The sandblasted brackets and silicoated brackets were viewed under the scanning electron microscope, immediately after surface conditioning before rebonding. The shear bond strength with each group was tested. One-way analysis of variance, post-hoc Scheffe multiple comparison tests. The results showed that sandblasting created more irregularities and deeper erosions while silica coating created superficial irregularities and shallow erosions.

  4. Report: Discussion on the development of nano Ag/TiO2 coating bracket and its antibacterial property and biocompatibility in orthodontic treatment.

    PubMed

    Zhang, Ronghe; Zhang, Weiwei; Bai, Xueyan; Song, Xiaotong; Wang, Chunyan; Gao, Xinxin; Tian, Xubiao; Liu, Fengzhen

    2015-03-01

    This paper aims to explore the antibacterial property of nano Ag/TiO2 coating bracket for the common bacteria in oral cavity, and discuss its biocompatibility. Micro morphology in the surface of nano Ag/TiO2 coating bracket was detected by scanning electron microscope (SEM), and surface roughness of ordinary mental bracket, nano TiO2 coating bracket and nano Ag/TiO2 coating bracket were measured. First, antibacterial property of nano Ag/TiO2 coating bracket on the common bacteria in oral cavity was studied by sticking membrane method. Secondly, bonding strength of nano TiO2 coating and nano Ag/TiO2 coating bracket in groups were detected by scratching test. The result showed that, the synthetic nano Ag/TiO2 coating was nanogranular films with rigorous organizational structure, presenting as smooth and clean surface, and antibacterial rate of nano Ag/TiO2 coating for the common bacteria in oral cavity for 20 min was more than 79% in the dark. All the findings suggested that, nano Ag/TiO2 coating bracket not only has antibacterial effect but also has good biocompatibility, therefore, it can satisfy the clinical request of orthodontic treatment.

  5. Friction Forces during Sliding of Various Brackets for Malaligned Teeth: An In Vitro Study

    PubMed Central

    Crincoli, Vito; Di Bisceglie, Maria Beatrice; Balsamo, Antonio; Serpico, Vitaliano; Chiatante, Francesco; Pappalettere, Carmine; Boccaccio, Antonio

    2013-01-01

    Aims. To measure the friction force generated during sliding mechanics with conventional, self-ligating (Damon 3 mx, Smart Clip, and Time 3) and low-friction (Synergy) brackets using different archwire diameters and ligating systems in the presence of apical and buccal malalignments of the canine. Methods. An experimental setup reproducing the right buccal segment of the maxillary arch was designed to measure the friction force generated at the bracket/wire and wire/ligature interfaces of different brackets. A complete factorial plan was drawn up and a three-way analysis of variance (ANOVA) was carried out to investigate whether the following factors affect the values of friction force: (i) degree of malalignment, (ii) diameter of the orthodontic wire, and (iii) bracket/ligature combination. Tukey post hoc test was also conducted to evaluate any statistically significant differences between the bracket/ligature combinations analyzed. Results. ANOVA showed that all the above factors affect the friction force values. The friction force released during sliding mechanics with conventional brackets is about 5-6times higher than that released with the other investigated brackets. A quasilinear increase of the frictional forces was observed for increasing amounts of apical and buccal malalignments. Conclusion. The Synergy bracket with silicone ligature placed around the inner tie-wings appears to yield the best performance. PMID:23533364

  6. Comparison of Microleakage under Rebonded Stainless Steel Orthodontic Brackets Using Two Methods of Adhesive Removal: Sandblast and Laser.

    PubMed

    Tudehzaeim, Mohamad Hossein; Yassaei, Soghra; Taherimoghadam, Shohreh

    2015-02-01

    Debonding is a common occurrence in orthodontic treatment and a considerable number of orthodontists prefer to rebond the detached brackets because of economic issues. The aim of this study was to compare the microleakage beneath rebonded stainless steel brackets using two methods of adhesive removal namely sandblast and laser. Sixty human premolar teeth were randomly divided into three groups. Following bonding the brackets, group 1 served as the control group. Brackets in groups 2 and 3 were debonded, and adhesive removal from the bracket bases was done by means of sandblasting and Er-YAG laser, respectively. After rebonding, teeth in each group were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope. Marginal microleakage at the adhesive-enamel and bracket-adhesive interfaces in the occlusal and gingival margins was determined. Statistical analysis was done using the Kruskal-Wallis test. Comparison of the microleakage scores among the three groups revealed no statistically significant difference (P > 0.05). At the enamel-adhesive interface, the gingival margins in all groups showed higher microleakage while in the adhesive-bracket interface, the occlusal margin exhibited greater microleakage. Er-YAG laser irradiation and sandblasting for adhesive removal from the debonded brackets yielded clinically acceptable microleakage scores.

  7. Comparison of Microleakage under Rebonded Stainless Steel Orthodontic Brackets Using Two Methods of Adhesive Removal: Sandblast and Laser

    PubMed Central

    Tudehzaeim, Mohamad Hossein; Yassaei, Soghra; Taherimoghadam, Shohreh

    2015-01-01

    Objectives: Debonding is a common occurrence in orthodontic treatment and a considerable number of orthodontists prefer to rebond the detached brackets because of economic issues. The aim of this study was to compare the microleakage beneath rebonded stainless steel brackets using two methods of adhesive removal namely sandblast and laser. Materials and Methods: Sixty human premolar teeth were randomly divided into three groups. Following bonding the brackets, group 1 served as the control group. Brackets in groups 2 and 3 were debonded, and adhesive removal from the bracket bases was done by means of sandblasting and Er-YAG laser, respectively. After rebonding, teeth in each group were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope. Marginal microleakage at the adhesive-enamel and bracket-adhesive interfaces in the occlusal and gingival margins was determined. Statistical analysis was done using the Kruskal-Wallis test. Results: Comparison of the microleakage scores among the three groups revealed no statistically significant difference (P > 0.05). At the enamel-adhesive interface, the gingival margins in all groups showed higher microleakage while in the adhesive-bracket interface, the occlusal margin exhibited greater microleakage. Conclusion: Er-YAG laser irradiation and sandblasting for adhesive removal from the debonded brackets yielded clinically acceptable microleakage scores. PMID:26056521

  8. Chromium release from new stainless steel, recycled and nickel-free orthodontic brackets.

    PubMed

    Sfondrini, Maria Francesca; Cacciafesta, Vittorio; Maffia, Elena; Massironi, Sarah; Scribante, Andrea; Alberti, Giancarla; Biesuz, Raffaela; Klersy, Catherine

    2009-03-01

    To test the hypothesis that there is no difference in the amounts of chromium released from new stainless steel brackets, recycled stainless steel brackets, and nickel-free (Ni-free) orthodontic brackets. This in vitro study was performed using a classic batch procedure by immersion of the samples in artificial saliva at various acidities (pH 4.2, 6.5, and 7.6) over an extended time interval (t(1) = 0.25 h, t(2) = 1 h, t(3) = 24 h, t(4) = 48 h, t(5) = 120 h). The amount of chromium release was determined using an atomic absorption spectrophotometer and an inductively coupled plasma atomic emission spectrometer. Statistical analysis included a linear regression model for repeated measures, with calculation of Huber-White robust standard errors to account for intrabracket correlation of data. For post hoc comparisons the Bonferroni correction was applied. The greatest amount of chromium was released from new stainless steel brackets (0.52 +/- 1.083 microg/g), whereas the recycled brackets released 0.27 +/- 0.38 microg/g. The smallest release was measured with Ni-free brackets (0.21 +/- 0.51 microg/g). The difference between recycled brackets and Ni-free brackets was not statistically significant (P = .13). For all brackets, the greatest release (P = .000) was measured at pH 4.2, and a significant increase was reported between all time intervals (P < .002). The hypothesis is rejected, but the amount of chromium released in all test solutions was well below the daily dietary intake level.

  9. In vitro assessment of competency for different lingual brackets in sliding mechanics.

    PubMed

    Lalithapriya, S; Kumaran, N Kurunji; Rajasigamani, K

    2015-01-01

    To determine the static frictional resistance of different lingual brackets at different second order angulations when coupled with stainless steel (SS) archwire in dry and wet conditions. Using a modified jig, frictional resistance was evaluated under different conditions for a total of 270 upper premolar lingual brackets (0.018″ × 0.025″ - conventional - 7(th) generation and STb, self-ligating - evolution) with no in-built tip or torque together with 0.016″ × 0.022″ straight length SS archwires. For conventional brackets, the archwire was secured with 0.008″ preformed SS short ligature ties. One way analysis of variance with Tukey HSD as post-hoc test was applied for degree wise and bracket wise comparison within dry condition and wet condition. For pair wise comparison Student's t-test was used. Under both conditions the static frictional resistance is significantly higher for self-ligating brackets at 0°, while at 5° and 10° it is higher for 7(th) generation brackets. Statistically, significant difference does not exist at 0° between conventional brackets and the same was found at 5° and 10° between STb and self-ligating brackets. With an increase in second order angulations, all the evaluated samples exhibited an increased frictional value. Wet condition samples obtained a higher value than their corresponding dry condition. The self-ligating bracket evaluated in this in vitro study is not beneficial in reducing friction during en-mass retraction due to its interactive clip type.

  10. Metallographic structure and hardness of titanium orthodontic brackets.

    PubMed

    Zinelis, Spiros; Annousaki, Olga; Eliades, Theodore; Makou, Margarita

    2003-11-01

    To determine the elemental composition, microstructure, and hardness of two different brands of titanium (Ti) orthodontic brackets. Four specimens of each brand were embedded in epoxy resin and, after metallographic grinding and polishing, were studied under a metallographic microscope. The bonding base morphology of each bracket was studied in as-received brackets by scanning electron microscopy. Energy dispersive x-ray microanalysis (EDS) was used on polished specimens to assess the elemental composition of base and wing bracket components, and the brackets were subjected to metallographic etching to reveal the metallurgical structure. The same specimen surfaces were used for assessment of the Vickers hardness. The results were statistically analyzed by two-way analysis of variance (ANOVA) with the bracket brand and bracket region (base, wing) serving as discriminating variables, whilst further group differences were investigated with Tukey's multiple comparison test at the alpha = 0.05 level of significance. Metallographic imaging revealed that the Orthos2 brackets (Ormco, Glendora, CA, USA) consist of two parts joined together by laser welding, with large gaps along the base wing interface, whereas Rematitan brackets (Dentaurum, Ispringen, Germany) are single-piece appliances. Ti was the only element identified in Rematitan and Orthos2 base materials, while aluminium (Al) and vanadium (V) were also found in the Orthos2 wing component. Metallographic analysis showed the presence of a + b phase for Orthos2 and plate-like grains for Rematitan. The results of the Vickers hardness testing were: Orthos2 (wing): 371 +/- 22, Rematitan (wing): 272 +/- 4, Rematitan (base): 271 +/- 16, Orthos2 (base): 165 +/- 2. The findings of the present study suggest that there are significant differences in composition, microstructure and hardness between the two commercial types of Ti brackets tested; the clinical implications of the findings are discussed.

  11. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study

    PubMed Central

    MENDES, Bernardo de Azevedo Bahia; FERREIRA, Ricardo Alberto Neto; PITHON, Matheus Melo; HORTA, Martinho Campolina Rebello; OLIVEIRA, Dauro Douglas

    2014-01-01

    Objective The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction. PMID:25025560

  12. Clinical acceptability of two self-etch adhesive resins for the bonding of orthodontic brackets to enamel.

    PubMed

    Schnebel, Bradley; Mateer, Scott; Maganzini, Anthony Louis; Freeman, Katherine

    2012-12-01

    To determine whether two self-adhesive resin cements, Clearfil SA and RelyX, can be used to successfully bond orthodontic brackets to enamel. Seventy extracted premolars were custom mounted, cleaned and randomly divided into three groups. In group 1 (control), orthodontic brackets were bonded to 25 premolars using the Transbond Plus and Transbond XT two step adhesive systerm adhesive. In group 2, brackets were bonded to 25 premolars using Clearfil SA. In group 3, brackets were bonded to 20 premolars using RelyX. The brackets were debonded using a universal testing machine and shear bond strengths recorded. After debonding, each tooth was examined under 20× magnification to evaluate the residual adhesive remaining. An ANOVA with Duncan's Multiple Range Test was used to determine whether there were significant differences in shear bond strength between the groups. A Kruskal-Wallis Test and a Bonferroni multiple comparison procedure were used to compare the bond failure modes (adhesive remnant index scores) between the groups. The mean shear bond strengths for the brackets bonded using Clearfil SA and RelyX were 5·930±1·840 and 3·334±1·953 MPa, respectively. Both were significantly lower than that for the brackets bonded using Transbond (7·875±3·611 MPa). Both self-etch adhesive resin cement groups showed a greater incidence of bracket failure at the enamel/adhesive interface while the Transbond group showed a higher incidence at the bracket/adhesive interface. The shear bond strengths of the self-etch adhesive resin cements may be inadequate to successfully bond orthodontic brackets to enamel.

  13. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study.

    PubMed

    Mendes, Bernardo de Azevedo Bahia; Neto Ferreira, Ricardo Alberto; Pithon, Matheus Melo; Horta, Martinho Campolina Rebello; Oliveira, Dauro Douglas

    2014-06-01

    The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction.

  14. Effects of silica coating and silane surface conditioning on the bond strength of metal and ceramic brackets to enamel.

    PubMed

    Atsü, Saadet Sağlam; Gelgör, Ibrahim Erhan; Sahin, Volkan

    2006-09-01

    To evaluate the effect of tribochemical silica coating and silane surface conditioning on the bond strength of metal and ceramic brackets bonded to enamel surfaces with light-cured composite resin. Twenty metal and 20 ceramic brackets were divided into four groups (n = 10 for each group). The specimens were randomly assigned to one of the following treatment conditions of the metal and ceramic brackets' surface: (1) tribochemical silica coating combined with silane and (2) no treatment. Brackets were bonded to the enamel surface on the labial and lingual sides of human maxillary premolars (20 total) with a light-polymerized resin composite. All specimens were stored in water for 1 week at 37 degrees C and then thermocycled (5000 cycles, 5 degrees C to 55 degrees C, 30 seconds). The shear bond strength values were measured on a universal testing machine. Student's t-test was used to compare the data (alpha = 0.05). The types of failures were observed using a stereomicroscope. Metal and ceramic brackets treated with silica coating with silanization had significantly greater bond strength values (metal brackets: 14.2 +/- 1.7 MPa, P < .01; ceramic brackets: 25.9 +/- 4.4 MPa, P < .0001) than the control groups (metal brackets: 11.9 +/- 1.3 MPa; ceramic brackets: 15.6 +/- 4.2 MPa). Treated specimens of metal and ceramic exhibited cohesive failures in resin and adhesive failures at the enamel-adhesive interface, whereas control specimens showed mixed types of failures. Silica coating with aluminum trioxide particles coated with silica followed by silanization gave higher bond strengths in both metal and ceramic brackets than in the control group.

  15. Effect of eliminating the residual fluoride gel on titanium bracket corrosion.

    PubMed

    Khoury, Elie S; Abboud, Maher; Bassil-Nassif, Nayla; Bouserhal, Joseph

    2011-09-01

    Fluoride ions, in long-term applications on titanium brackets, cause their corrosion. Fluoride gel used for caries prevention during orthodontic treatment has a very high concentration in fluoride ions, and therefore has the potential for causing bracket corrosion. The main aim of this study was to determine the effect of eliminating the residual fluoride gel, by rinsing it, on the corrosion of titanium brackets. The secondary aim was to evaluate the corrosion of titanium brackets in the presence of fluoride gel. One hundred titanium brackets were divided into five groups of 20 brackets each. Group 1 being the control group, the rest of the groups were immersed in fluoride gel: Group 2 for 4 minutes and kept for 30 minutes with the residual fluoride gel on; Group 3 for 4 minutes followed by immediate water rinsing; Group 4 for 12 minutes and kept for 90 minutes with the residual fluoride gel on and Group 5 for 12 minutes followed by immediate water rinsing. All groups were rinsed then dried, for 20 hours, using Silica gel in a desiccator maintained at 37°C before testing. Gravimetrical results and SEM analysis showed no significant difference between Groups 2, 3 and 5 compared to each other and to the control group. Only Group 4 showed significant weight loss and pitting corrosion in four of the 20 brackets. In sliding resistance, no significant difference was detected between any of the groups. Short time applications of fluoride gel do not affect sliding resistance of titanium brackets. No titanium corrosion was detected for one application of concentrated fluoride gel and some brackets showed pitting corrosion for three applications. The rinsing of residual fluoride gel eliminates completely the risk of bracket corrosion. Copyright © 2011 CEO. Published by Elsevier Masson SAS. All rights reserved.

  16. Friction between various self-ligating brackets and archwire couples during sliding mechanics.

    PubMed

    Stefanos, Sennay; Secchi, Antonino G; Coby, Guy; Tanna, Nipul; Mante, Francis K

    2010-10-01

    The aim of this study was to evaluate the frictional resistance between active and passive self-ligating brackets and 0.019 × 0.025-in stainless steel archwire during sliding mechanics by using an orthodontic sliding simulation device. Maxillary right first premolar active self-ligating brackets In-Ovation R, In-Ovation C (both, GAC International, Bohemia, NY), and SPEED (Strite Industries, Cambridge, Ontario, Canada), and passive self-ligating brackets SmartClip (3M Unitek, Monrovia, Calif), Synergy R (Rocky Mountain Orthodontics, Denver, Colo), and Damon 3mx (Ormco, Orange, Calif) with 0.022-in slots were used. Frictional force was measured by using an orthodontic sliding simulation device attached to a universal testing machine. Each bracket-archwire combination was tested 30 times at 0° angulation relative to the sliding direction. Statistical comparisons were performed with 1-way analysis of variance (ANOVA) followed by Dunn multiple comparisons. The level of statistical significance was set at P <0.05. The Damon 3mx brackets had significantly the lowest mean static frictional force (8.6 g). The highest mean static frictional force was shown by the SPEED brackets (83.1 g). The other brackets were ranked as follows, from highest to lowest, In-Ovation R, In-Ovation C, SmartClip, and Synergy R. The mean static frictional forces were all statistically different. The ranking of the kinetic frictional forces of bracket-archwire combinations was the same as that for static frictional forces. All bracket-archwire combinations showed significantly different kinetic frictional forces except SmartClip and In-Ovation C, which were not significantly different from each other. Passive self-ligating brackets have lower static and kinetic frictional resistance than do active self-ligating brackets with 0.019 × 0.025-in stainless steel wire. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  17. Spectrophotometric evaluation of dental bleaching under orthodontic bracket in enamel and dentin

    PubMed Central

    Correr, Americo-Bortolazzo; Rastelli, Alessandra-Nara-Souza; Lima, Débora-Alves-Nunes-Leite; Consani, Rafael-Leonardo-Xediek

    2014-01-01

    Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments. Key words:Tooth bleaching, spectrophotometry, orthodontics. PMID:25593650

  18. Can 10% hydrofluoric acid be used for reconditioning of orthodontic brackets?

    PubMed

    Pompeo, Daniela D; Rosário, Henrique D; Lopes, Beatriz Mv; Cesar, Paulo F; Paranhos, Luiz Renato

    2016-01-01

    Bracket debonding is a common problem during orthodontic treatment. This type of failure is associated to masticatory forces, poor adhesion, and the need for repositioning the piece. The objective of this work was to compare the shear bond strength of debonded brackets that were reconditioned using different protocols (alumina blasting versus hydrofluoric etching). This was an in vitro experimental study with 45 stainless steel orthodontic brackets. They were randomly divided into three groups: (1) New brackets (n = 15), (2) brackets reconditioned using 10% hydrofluoric acid for 60 s (n = 15), and (3) brackets reconditioned by aluminum oxide blasting until complete removal of the remaining resin (n = 15). In Groups 2 and 3, the insertion of composite resin proceeded in two stages to simulate a type of bracket failure in which the bonding resin was left at the bracket base. For the shear test, the assembly composed by the metallic support, and specimen was taken to the Instron universal testing machine in which the specimens were loaded using a semicircle-shaped active tip in the region of the bonding interface parallel to the surface of the bracket at a speed of 0.5 mm/min. The data were subjected to D'Agostino's normality test to have their distribution checked. Analysis of variance and Tukey's test (P < 0.01) were used to compare the findings between groups. The results indicated that Group 1 (new brackets) showed higher bond strength than that obtained for the group treated with hydrofluoric acid (Group 2, P < 0.01). The bond strength value obtained for the group treated with alumina blasting (Group 3) was statistically similar to those obtained for Groups 1 and 2. The aluminum oxide blasting technique was effective for the reconditioning of orthodontic brackets. Nevertheless, the reconditioning technique using 10% fluoridric acid for 60 s was not efficient for clinical use.

  19. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

    PubMed

    Leite, Vanessa Vieira; Lopes, Murilo Baena; Gonini Júnior, Alcides; Almeida, Marcio Rodrigues de; Moura, Sandra Kiss; Almeida, Renato Rodrigues de

    2014-01-01

    To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a 0.10-in ligating wire was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P < 0.05), which also differed from each other (P < 0.05). As for the type of wire, 0.019 x 0.025-in steel wire (5.67 ± 3.97) showed lower means (P < 0.05) than 0.16-in NiTi wire (8.26 ± 10.92) and 0.016 x 0.021-in NiTi wire (8.51 ± 7.95), which did not differ from each other (P > 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied.

  20. Influence of long-term in vivo exposure, debris accumulation and archwire material on friction force among different types of brackets and archwires couples.

    PubMed

    Mezeg, Uroš; Primožic, Jasmina

    2017-11-30

    The aim was to assess the influence of long-term in vivo exposure, debris accumulation and archwire material on static and kinetic friction force among different types of brackets and archwires couples. Friction testing was performed among four lower incisors' brackets, conventional and self-ligating (SL), coupled with either nickel-titanium or stainless steel archwires, as-received and in vivo exposed in 18 subjects. The friction testing was performed for a sliding distance of 14 mm at a speed of 10 mm/min, with a starting force of 0.2 N. Wear and quantitative assessment of debris accumulation was performed on pictures of brackets obtained using a scanning electron microscope. Non parametric tests were used for statistical analysis. Only bracket type, but not exposure duration, amount of debris accumulation, archwire material or their manufacturer, was significantly correlated with both static (rho = 0.602, P < 0.001) and kinetic (rho = 0.584, P < 0.001) friction force. Within each bracket type no significant difference was observed between as-received and in vivo exposed brackets for any friction parameter except for the SL brackets in which significantly higher static and kinetic (P = 0.001, at least) friction forces were seen in in vivo exposed SL brackets (164.9 cN and 217.63 cN, respectively) in comparison with as-received SL brackets (19.69 cN and 55.72 cN, respectively). The frictional testing was performed in the dry condition which might have influenced the results. A significant correlation was seen between friction force and bracket type, while treatment duration, amount of debris accumulation, archwire material or their manufacturer was not significantly correlated to it. Nevertheless, higher friction forces were measured among in vivo aged SL brackets in comparison with as-received ones. © The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  1. Evaluation of the effect of three innovative recyling methods on the shear bond strength of stainless steel brackets-an in vitro study.

    PubMed

    Gupta, Neeraj; Kumar, Dilip; Palla, Aparna

    2017-04-01

    Orthodontists are commonly faced with the decision of what to do with debonded or inaccurately positioned brackets. An economical option to this dilemma is to recycle the brackets. Many recycling methods have been proposed, but the optimal bond strength of these recycled brackets needs further evaluation. Objectives: To evaluate and compare the effect of three recycling methods: (i) Sandblasting (ii) Sandblasting / direct flaming (iii) Sandblasting /direct flaming /acid bath solution on shear bond strength (SBS) of stainless steel brackets. Eighty human premolars were bonded with premolar stainless steel brackets as per manufacturer's instructions. The teeth were divided into 4 groups (n=20): Recycling and initial debonding was not done in Control group (Group I). After initial bonding, the brackets in the rest of the three experimental groups were debonded and recycled by following methods: (i) Sandblasting (Group II) (ii) Sandblasting /direct flaming (Group III) (iii) Sandblasting /direct flaming /acid bath solution (Group IV). Further the recycled brackets were bonded. The specimens were then subjected to testing in a Universal machine. The evaluation of the variation of the shear bond strength (SBS) among test groups was done using one-way ANOVA test and inter-experimental group comparison was done by Newman-Keuls multiple post hoc procedure. Group I (8.6510±1.3943MPa) showed the highest bond strength followed by Group II (5.0185±0.9758MPa), Group IV (2.30±0.65MPa) and Group III (2.0455± 0.6196MPa). Statistically significant variations existed in the shear bond strength (SBS) in all groups analyzed except between Group III and Group IV. The following conclusions were drawn from the study: 1. Shear bond strength of new brackets is significantly higher than the recycled brackets. 2. Brackets sandblasted with 90µm aluminium oxide particle air-abrasion showed significantly higher shear bond strength compared to direct flaming/sandblasting and direct flaming/sandblasting/acid bath solution. 3. Sandblasting with 90µm aluminium oxide particle air-abrasion is the simplest, most efficient and hence, the preferred method of recycling debonded brackets. Key words: Orthodontic bracket, recycling, shear bond strength.

  2. Statistical theory for the Kardar-Parisi-Zhang equation in (1+1) dimensions.

    PubMed

    Masoudi, A A; Shahbazi, F; Davoudi, J; Tabar, M Reza Rahimi

    2002-02-01

    The Kardar-Parisi-Zhang (KPZ) equation in (1+1) dimensions dynamically develops sharply connected valley structures within which the height derivative is not continuous. We develop a statistical theory for the KPZ equation in (1+1) dimensions driven with a random forcing that is white in time and Gaussian-correlated in space. A master equation is derived for the joint probability density function of height difference and height gradient P(h-h*, partial differential(x)h,t) when the forcing correlation length is much smaller than the system size and much larger than the typical sharp valley width. In the time scales before the creation of the sharp valleys, we find the exact generating function of h-h* and partial differential(x)h. The time scale of the sharp valley formation is expressed in terms of the force characteristics. In the stationary state, when the sharp valleys are fully developed, finite-size corrections to the scaling laws of the structure functions left angle bracket(h-h*)(n)(partial differential(x)h)(m)right angle bracket are also obtained.

  3. A Diagrammatic Language for Biochemical Networks

    NASA Astrophysics Data System (ADS)

    Maimon, Ron

    2002-03-01

    I present a diagrammatic language for representing the structure of biochemical networks. The language is designed to represent modular structure in a computational fasion, with composition of reactions replacing functional composition. This notation is used to represent arbitrarily large networks efficiently. The notation finds its most natural use in representing biological interaction networks, but it is a general computing language appropriate to any naturally occuring computation. Unlike lambda-calculus, or text-derived languages, it does not impose a tree-structure on the diagrams, and so is more effective at representing biological fucntion than competing notations.

  4. The Effect of Bracket Base Pylon Orientation on the Shear Bond Strength of the ODP ANCHOR-LOCK Bracket Pad

    DTIC Science & Technology

    2013-06-06

    El Banna MS, Elsaka SE. Twelve-month bracket failure rate with amorphous calcium phosphate bonding system. Eur J Orthod 2012; doi:10.1093/ejo...material, Cambridge University Press. 1993;3. Willems G, Carels CEL, Verbeke G. In vitro peel /shear bond strength evaluation of orthodontic bracket

  5. Apparatuses to support photovoltaic modules

    DOEpatents

    Ciasulli, John; Jones, Jason

    2017-08-22

    Methods and apparatuses to support photovoltaic ("PV") modules are described. A saddle bracket has a mounting surface to support one or more PV modules over a tube, a gusset coupled to the mounting surface, and a mounting feature coupled to the gusset to couple to the tube. A grounding washer has a first portion to couple to a support; and a second portion coupled to the first portion to provide a ground path to a PV module. A PV system has a saddle bracket; a PV module over the saddle bracket; and a grounding washer coupled to the saddle bracket and the PV module. Saddle brackets can be coupled to a torque tube at predetermined locations. PV modules can be coupled to the saddle brackets.

  6. Influence of the bracket on bonding and physical behavior of orthodontic resin cements.

    PubMed

    Bolaños-Carmona, Victoria; Zein, Bilal; Menéndez-Núñez, Mario; Sánchez-Sánchez, Purificación; Ceballos-García, Laura; González-López, Santiago

    2015-01-01

    The aim of the study is to determine the influence of the type of bracket, on bond strength, microhardness and conversion degree (CD) of four resin orthodontic cements. Micro-tensile bond strength (µTBS) test between the bracket base and the cement was carried out on glass-hour-shaped specimens (n=20). Vickers Hardness Number (VHN) and micro-Raman spectra were recorded in situ under the bracket base. Weibull distribution, ANOVA and non-parametric test were applied for data analysis (p<0.05). The highest values of ή as well as the β Weibull parameter were obtained for metallic brackets with Transbond™ plastic brackets with the self-curing cement showing the worst performance. The CD was from 80% to 62.5%.

  7. Safety Case Notations: Alternatives for the Non-Graphically Inclined?

    NASA Technical Reports Server (NTRS)

    Holloway, C. M.

    2008-01-01

    This working paper presents preliminary ideas of five possible text-based notations for representing safety cases, which may be easier for non-graphically inclined people to use and understand than the currently popular graphics-based representations.

  8. The role of line junctions in object recognition: The case of reading musical notation.

    PubMed

    Wong, Yetta Kwailing; Wong, Alan C-N

    2018-04-30

    Previous work has shown that line junctions are informative features for visual perception of objects, letters, and words. However, the sources of such sensitivity and their generalizability to other object categories are largely unclear. We addressed these questions by studying perceptual expertise in reading musical notation, a domain in which individuals with different levels of expertise are readily available. We observed that removing line junctions created by the contact between musical notes and staff lines selectively impaired recognition performance in experts and intermediate readers, but not in novices. The degree of performance impairment was predicted by individual fluency in reading musical notation. Our findings suggest that line junctions provide diagnostic information about object identity across various categories, including musical notation. However, human sensitivity to line junctions does not readily transfer from familiar to unfamiliar object categories, and has to be acquired through perceptual experience with the specific objects.

  9. A comparison of BPMN 2.0 with other notations for manufacturing processes

    NASA Astrophysics Data System (ADS)

    García-Domínguez, A.; Marcos, Mariano; Medina, I.

    2012-04-01

    In order to study their current practices and improve on them, manufacturing firms need to view their processes from several viewpoints at various abstraction levels. Several notations have been developed for this purpose, such as Value Stream Mappings or IDEF models. More recently, the BPMN 2.0 standard from the Object Management Group has been proposed for modeling business processes. A process organizes several activities (manual or automatic) into a single higher-level entity, which can be reused elsewhere in the organization. Its potential for standardizing business interactions is well-known, but there is little work on using BPMN 2.0 to model manufacturing processes. In this work some of the previous notations are outlined and BPMN 2.0 is positioned among them after discussing it in more depth. Some guidelines on using BPMN 2.0 for manufacturing are offered, and its advantages and disadvantages in comparison with the other notations are presented.

  10. Calculation of four-particle harmonic-oscillator transformation brackets

    NASA Astrophysics Data System (ADS)

    Germanas, D.; Kalinauskas, R. K.; Mickevičius, S.

    2010-02-01

    A procedure for precise calculation of the three- and four-particle harmonic-oscillator (HO) transformation brackets is presented. The analytical expressions of the four-particle HO transformation brackets are given. The computer code for the calculations of HO transformation brackets proves to be quick, efficient and produces results with small numerical uncertainties. Program summaryProgram title: HOTB Catalogue identifier: AEFQ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEFQ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 1247 No. of bytes in distributed program, including test data, etc.: 6659 Distribution format: tar.gz Programming language: FORTRAN 90 Computer: Any computer with FORTRAN 90 compiler Operating system: Windows, Linux, FreeBSD, True64 Unix RAM: 8 MB Classification: 17.17 Nature of problem: Calculation of the three-particle and four-particle harmonic-oscillator transformation brackets. Solution method: The method is based on compact expressions of the three-particle harmonics oscillator brackets, presented in [1] and expressions of the four-particle harmonics oscillator brackets, presented in this paper. Restrictions: The three- and four-particle harmonic-oscillator transformation brackets up to the e=28. Unusual features: Possibility of calculating the four-particle harmonic-oscillator transformation brackets. Running time: Less than one second for the single harmonic-oscillator transformation bracket. References:G.P. Kamuntavičius, R.K. Kalinauskas, B.R. Barret, S. Mickevičius, D. Germanas, Nuclear Physics A 695 (2001) 191.

  11. Comparison of Antibacterial Effects of ZnO and CuO Nanoparticles Coated Brackets against Streptococcus Mutans.

    PubMed

    Ramazanzadeh, Baratali; Jahanbin, Arezoo; Yaghoubi, Masoud; Shahtahmassbi, Nasser; Ghazvini, Kiarash; Shakeri, Mohammadtaghi; Shafaee, Hooman

    2015-09-01

    During the orthodontic treatment, microbial plaques may accumulate around the brackets and cause caries, especially in high-risk patients. Finding ways to eliminate this microbial plaque seems to be essential. The aim of this study was to compare the antibacterial effects of nano copper oxide (CuO) and nano zinc oxide (ZnO) coated brackets against Streptococcus mutans (S.mutans) in order to decrease the risk of caries around the orthodontic brackets during the treatment. Sixty brackets were coated with nanoparticles of ZnO (n=20), CuO (n=20) and CuO-ZnO (n=20). Twelve uncoated brackets constituted the control group. The brackets were bonded to the crowns of extracted premolars, sterilized and prepared for antimicrobial tests (S.mutans ATCC35668). The samples taken after 0, 2, 4, 6 and 24 hours were cultured on agar plates. Colonies were counted 24 hours after incubation. One-way ANOVA and Tukey tests were used for statistical analysis. In CuO and CuO-ZnO coated brackets, no colony growth was seen after two hours. Between 0-6 hours, the mean colony counts were not significantly different between the ZnO and the control group (p>0.05). During 6-24 hours, the growth of S.mutans was significantly reduced by ZnO nanoparticles in comparison with the control group (p< 0.001). However, these bacteria were not totally eliminated. CuO and ZnO-CuO nanoparticles coated brackets have better antimicrobial effect on S.mutans than ZnO coated brackets.

  12. Is laser conditioning a valid alternative to conventional etching for aesthetic brackets?

    PubMed

    Sfondrini, M F; Calderoni, G; Vitale, M C; Gandini, P; Scribante, A

    2018-03-01

    ER:Yag lasers have been described as a more conservative alternative to conventional acid-etching enamel conditioning technique, when bonding conventional metallic orthodontic brackets. Since the use of aesthetic orthodontic brackets is constantly increasing, the purpose of the present report has been to test laser conditioning with different aesthetic brackets. Study Design: Five different aesthetic brackets (microfilled copolymer, glass fiber, sapphire, polyoxymethylene and sintered ceramic) were tested for shear bond strength and Adhesive Remnant Index scores using two different enamel conditioning techniques (acid etching and ER:Yag laser application). Two hundred bovine incisors were extracted, cleaned and embedded in resin. Specimens were then divided into 10 groups with random tables. Half of the specimens were conditioned with conventional orthophosphoric acid gel, the other half with ER:Yag laser. Different aesthetic brackets (microfilled copolymer, glass fiber, sapphire, polyoxymethylene and sintered ceramic) were then bonded to the teeth. Subsequently all groups were tested in shear mode with a Universal Testing Machine. Shear bond strength values and adhesive remnant index scores were recorded. Statistical analysis was performed. When considering conventional acid etching technique, sapphire, polyoxymethylene and sintered ceramic brackets exhibited the highest SBS values. Lowest values were reported for microfilled copolymer and glass fiber appliances. A significant decrease in SBS values after laser conditioning was reported for sapphire, polyoxymethylene and sintered ceramic brackets, whereas no significant difference was reported for microfilled copolymer and glass fiber brackets. Significant differences in ARI scores were also reported. Laser etching can significantly reduce bonding efficacy of sapphire, polyoxymethylene and sintered ceramic brackets.

  13. 3D-printed orthodontic brackets - proof of concept.

    PubMed

    Krey, Karl-Friedrich; Darkazanly, Nawras; Kühnert, Rolf; Ruge, Sebastian

    Today, orthodontic treatment with fixed appliances is usually carried out using preprogrammed straight-wire brackets made of metal or ceramics. The goal of this study was to determine the possibility of clinically implementing a fully digital workflow with individually designed and three-dimensionally printed (3D-printed) brackets. Edgewise brackets were designed using computer-aided design (CAD) software for demonstration purposes. After segmentation of the malocclusion model generated based on intraoral scan data, the brackets were digitally positioned on the teeth and a target occlusion model created. The thus-defined tooth position was used to generate a template for an individualized arch form in the horizontal plane. The base contours of the brackets were modified to match the shape of the tooth surfaces, and a positioning guide (fabricated beforehand) was used to ensure that the brackets were bonded at the correct angle and position. The brackets, positioning guide, and retainer splint, digitally designed on the target occlusion model, were 3D printed using a Digital Light Processing (DLP) 3D printer. The archwires were individually pre-bent using the template. In the treatment sequence, it was shown for the first time that, in principle, it is possible to perform treatment with an individualized 3D-printed brackets system by using the proposed fully digital workflow. Technical aspects of the system, problems encountered in treatment, and possible future developments are discussed in this article.

  14. Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets.

    PubMed

    Sohrabi, Aydin; Jafari, Sanaz; Kimyai, Soodabeh; Rikhtehgaran, Sahand

    2016-10-01

    Since there is no standard method for rebonding loose ceramic brackets, the aim of this study was to evaluate the possibility of using Er,Cr:YSGG laser to eliminate the remaining composite materials from the base of ceramic brackets and to compare the bond strength of rebonded brackets with the new ones. Sixty-two extracted human premolars were mounted in acrylic cylinders. Thirty-one ceramic brackets were bonded, and shear bond strength was tested using Hounsfield testing machine. The remnants of the bonding material were removed from the bases of brackets using Er,Cr:YSGG laser. These brackets were rebonded to 31 fresh teeth and again shear bond strength was measured. Pattern of debonding was assessed in both cases under a stereomicroscope and graded according to ARI index. Data were analyzed with independent t-test and Fisher's exact test. Mean shear bond strength of the bond and rebond groups was 12.29 ± 5.46 and 10.58 ± 5.16 MPa, respectively. There were no significant differences between the two groups (p = 0.21). Pattern of bond failure was not statistically different between the two groups. Er,Cr:YSGG laser was effective in removing the remnants of bonding material from the base of ceramic brackets without any interference with the ceramic base itself, demonstrating that it might be a suitable method for rebonding ceramic brackets.

  15. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane.

    PubMed

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  16. Antimicrobial action of chlorhexidine digluconate in self-ligating and conventional metal brackets infected with Streptococcus mutans biofilm

    PubMed Central

    Dias, Ana Paula; Paschoal, Marco Aurélio Benini; Diniz, Rafael Soares; Lage, Lucas Meneses; Gonçalves, Letícia Machado

    2018-01-01

    Objectives The objectives of this study were to assess the adherence of Streptococcus mutans biofilms grown over conventional ligature (CL) or self-ligating (SL) metal brackets and their bacterial viability after 0.12% chlorhexidine (CHX) digluconate treatment. Materials and methods The sample consisted of 48 metallic orthodontic brackets divided randomly into two groups: CL (n=24) and SL brackets (n=24). S. mutans biofilms were grown over the bracket surface (96 h) and treated with CHX (positive control) or 0.9% phosphate-buffered saline (PBS) (negative control) for 1 min each. Quantitative analysis was assessed by colony-forming units, and fluorescence microscopy was performed aiming to illustrate the outcomes. The tests were done in triplicate at three different times (n=9). Data were analyzed using ANOVA and Tukey test (P<0.05). Results There were significant differences in brackets’ biofilm formation, being CL largely colonized compared with SL, which was observed by colony-forming unit counting (P<0.05) and microcopy images. Significant reduction in the viability of S. mutans was found in both brackets treated with CHX compared to PBS (P<0.05). Conclusion The antimicrobial activities of CHX were similar for CL and SL brackets (P>0.05). In conclusion, a lower colonization was achieved in SL brackets and S. mutans biofilms were susceptible to CHX treatment to both studied brackets. PMID:29719422

  17. Root resorption during orthodontic treatment with self-ligating or conventional brackets: a systematic review and meta-analysis.

    PubMed

    Yi, Jianru; Li, Meile; Li, Yu; Li, Xiaobing; Zhao, Zhihe

    2016-11-21

    The aim of this study was to compare the external apical root resorption (EARR) in patients receiving fixed orthodontic treatment with self-ligating or conventional brackets. Studies comparing the EARR between orthodontic patients using self-ligating or conventional brackets were identified through electronic search in databases including CENTRAL, PubMed, EMBASE, China National Knowledge Infrastructure (CNKI) and SIGLE, and manual search in relevant journals and reference lists of the included studies until Apr 2016. The extraction of data and risk of bias evaluation were conducted by two investigators independently. The original outcome underwent statistical pooling by using Review Manager 5. Seven studies were included in the systematic review, out of which, five studies were statistically pooled in meta-analysis. The value of EARR of maxillary central incisors in the self-ligating bracket group was significantly lower than that in the conventional bracket group (SMD -0.31; 95% CI: -0.60--0.01). No significant differences in other incisors were observed between self-ligating and conventional brackets. Current evidences suggest self-ligating brackets do not outperform conventional brackets in reducing the EARR in maxillary lateral incisors, mandible central incisors and mandible lateral incisors. However, self-ligating brackets appear to have an advantage in protecting maxillary central incisor from EARR, which still needs to be confirmed by more high-quality studies.

  18. Gingival response in orthodontic patients: Comparative study between self-ligating and conventional brackets.

    PubMed

    Folco, Alejandra A; Benítez-Rogé, Sandra C; Iglesias, Marina; Calabrese, Diana; Pelizardi, Cristina; Rosa, Alcira; Brusca, Marisa I; Hecht, Pedro; Mateu, María E

    2014-01-01

    Orthodontic brackets contribute to the accumulation of bacterial plaque on tooth surfaces because they hinder oral hygiene. In contrast to conventional brackets, self-ligating brackets do not require additional parts to support the arches, thus improving dental hygiene. The aim of this study was to compare the gingival response in orthodontic patients wearing self-ligating or conventional brackets. A sample of 22 patients aged 16 to 30 years was divided into two groups: Group A, treated with selfligating brackets (Damon system) and Group B, treated with conventional brackets (Roth technique). The following were assessed during the treatment: Plaque Index (PI), Gingival Index (GI) and Probing Depth (PD), and sub-gingival samples were taken from teeth 14/24 for microbiological observation. No statistically significant difference was found between Groups A and B; p>0.05 (sign-ranked) or between PI, GI and PD at the different times (Friedman's Analysis of Variance), even though the indices were found to increase at 14 days, particularly for self-ligating brackets. The quantity and quality of microorganisms present were compatible with health on days 0, 28 and 56. As from day 14 there is a predominance of microbiota compatible with gingivitis in both groups. In the samples studied, orthodontic treatment increases bacterial plaque and inflammatory gingival response, but gingival-periodontal health can be maintained with adequate basic therapy. Self-ligating and conventional brackets produced similar gingival response.

  19. 75 FR 50856 - Airworthiness Directives; Airbus Model A380-800 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... been found on the Droop Nose (DN) 1 master sidestay bracket on the inboard leading edge of an Airbus A380 flight test aeroplane. In case of failure of the master bracket, the sub-master bracket would be... been found on the Droop Nose (DN) 1 master sidestay bracket on the inboard leading edge of an Airbus...

  20. Preliminary Process Design of ITER ELM Coil Bracket Brazing

    NASA Astrophysics Data System (ADS)

    LI, Xiangbin; SHI, Yi

    2015-03-01

    With the technical requirement of the International Thermonuclear Experimental Reactor (ITER) project, the manufacture and assembly technology of the mid Edge Localized Modes (ELM) coil was developed by the Institute of Plasma Physics, Chinese Academy of Science (ASIPP). As the gap between the bracket and the Stainless Steel jacketed and Mineral Insulated Conductor (SSMIC) can be larger than 0.5 mm instead of 0.01 mm to 0.1 mm as in normal industrial cases, the process of mid ELM coil bracket brazing to the SSMICT becomes quiet challenging, from a technical viewpoint. This paper described the preliminary design of ELM coil bracket brazing to the SSMIC process, the optimal bracket brazing curve and the thermal simulation of the bracket furnace brazing method developed by ANSYS. BAg-6 foil (Bag50Cu34Zn16) plus BAg-1a paste (Bag45CuZnCd) solders were chosen as the brazing filler. By testing an SSMICT prototype, it is shown that the average gap between the bracket and the SSMIC could be controlled to 0.2-0.3 mm, and that there were few voids in the brazing surface. The results also verified that the preliminary design had a favorable heat conducting performance in the bracket.

  1. Role of lubricants on friction between self-ligating brackets and archwires.

    PubMed

    Leal, Renata C; Amaral, Flávia L B; França, Fabiana M G; Basting, Roberta T; Turssi, Cecilia P

    2014-11-01

    To evaluate the effect of different lubricants on friction between orthodontic brackets and archwires. Active (Quick, Forestadent) and passive (Damon 3MX, Ormco) self-ligating brackets underwent friction tests in the presence of mucin- and carboxymethylcellulose (CMC)-based artificial saliva, distilled water, and whole human saliva (positive control). Dry friction (no lubricant) was used as the negative control. Bracket/wire samples (0.014 × 0.025 inch, CuNiTi, SDS Ormco) underwent friction tests eight times in a universal testing machine. Two-way analysis of variance showed no significant interaction between bracket type and lubricant (P  =  .324). Friction force obtained with passive self-ligating brackets was lower than that for active brackets (P < .001). Friction observed in the presence of artificial saliva did not differ from that generated under lubrication with natural human saliva, as shown by Tukey test. Higher friction forces were found with the use of distilled water or when the test was performed under dry condition (ie, with no lubricant). Lubrication plays a role in friction forces between self-ligating brackets and CuNiTi wires, with mucin- and CMC-based artificial saliva providing a reliable alternative to human natural saliva.

  2. Colour stability of aesthetic brackets: ceramic and plastic.

    PubMed

    Filho, Hibernon Lopes; Maia, Lúcio Henrique; Araújo, Marcus V; Eliast, Carlos Nelson; Ruellas, Antônio Carlos O

    2013-05-01

    The colour stability of aesthetic brackets may differ according to their composition, morphology and surface property, which may consequently influence their aesthetic performance. To assess the colour stability of aesthetic brackets (ceramic and plastic) after simulating aging and staining. Twelve commercially manufactured ceramic brackets and four different plastic brackets were assessed. To determine possible colour change (change of E*(ab)) and the value of the NBS (National Bureau of Standards) unit system, spectrophotometric colour measurements for CIE L*, a* and b* were taken before and after the brackets were aged and stained. Statistical analysis was undertaken using a one-way ANOVA analysis of variance and a Tukey multiple comparison test (alpha = 0.05). The colour change between the various (ceramic and plastic) materials was not significant (p > 0.05), but still varied significantly (p < 0.001) between the brackets of the same composition or crystalline structure and among commercial brands. Colour stability cannot be confirmed simply by knowing the type of material and crystalline composition or structure.

  3. Deformation of metal brackets: a comparative study.

    PubMed

    Flores, D A; Choi, L K; Caruso, J M; Tomlinson, J L; Scott, G E; Jeiroudi, M T

    1994-01-01

    The purpose of this study was to determine the effect of material and design on the force and stress required to permanently deform metal brackets. Fourteen types of metal brackets were categorized according to raw material composition, slot torque degree, and wing type. Five types of raw materials, three types of slot torque degree, and four types of wing design were tested using an archwire torque test developed by Flores. An analysis of variance (ANOVA) and t-test showed that all three categories had a significant effect on the force and stress needed to permanently deform metal brackets. Of the three, raw material had the greatest effect on the amount of force. Results showed that 17-4PH and 303S had higher yield strengths and regular twin brackets had higher resistance to deformation. Also, as slot torque degree increased, brackets deformed with less force. Result confirmed that brackets requiring the greatest stress to permanently deform were made of steel with the greatest hardness.

  4. Investigation of bracket bonding for orthodontic treatments using en-face optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Sinescu, Cosmin; Negrutiu, Meda L.; Hughes, Michael; Bradu, Adrian; Todea, Carmen; Rominu, Roxana; Dodenciu, Dorin; Laissue, Philippe L.; Podoleanu, Adrian G.

    2008-04-01

    Despite good diagnosis and treatment planning, orthodontic treatment can fail if bonding fails. It is now common practice to address the aesthetic appearance of patients using aesthetic brackets instead of metal ones. Therefore, bonding aesthetic brackets has become an issue for orthodontists today. Orthodontic bonding is mainly achieved using composite resin but can also be performed with glass ionomer or resin cements. For improving the quality of bonding, the enamel is acid etched for 30 seconds with 38% phosphoric acid and then a bonding agent is applied. In our study we investigated and compared the quality of bonding between ceramic brackets, polymeric brackets and enamel, respectively using a new investigation method-OCT. The aim of our study was to evaluate the resin layer at the bracket base-tooth interface.

  5. Robot cable-compliant devices

    NASA Technical Reports Server (NTRS)

    Kerley, James J., Jr. (Inventor)

    1990-01-01

    A cable compliant robotic joint includes two U configuration cross section brackets with their U cross sections lying in different planes, one of their brackets being connected to a robot arm and the other to a tool. Additional angle brackets are displaced from the other brackets at corners of the robotic joint. All the brackets are connected by cable segments which lie in one or more planes which are perpendicular to the direction of tool travel as it approaches a work object. The compliance of the joint is determined by the cable segment characteristics, such as their length, material, angle, stranding, pretwisting, and prestressing.

  6. Friction behavior of self-ligating and conventional brackets with different ligature systems.

    PubMed

    Szczupakowski, Alexandra; Reimann, Susanne; Dirk, Cornelius; Keilig, Ludger; Weber, Anna; Jäger, Andreas; Bourauel, Christoph

    2016-07-01

    Self-ligating brackets are widely believed to offer better clinical efficiency and, in particular, less friction. Thus, the goal of this in vitro investigation was to assess the friction behavior of different bracket/archwire/ligature combinations during simulated canine retraction. An important aspect of this work was to determine whether conventional bracket systems behave differently in passive or active self-ligating brackets used with a Slide™ ligature, an elastic ligature, or a steel ligature. Three conventional (Contour, Class One; Discovery(®), Dentaurum; Mystique MB, GAC) and six self-ligating (Carriere SL, Class One; Clarity™ SL, 3M Unitek; Damon3, Ormco; In-Ovation(®) C, GAC; Speed Appliance, Speed System™; QuicKlear(®), Forestadent(®)) bracket systems were analyzed. All brackets featured a 0.022″ slot (0.56 mm). Each conventional system was tested with a steel ligature (0.25 mm; Remanium(®), Dentaurum), an elastic ligature (1.3 mm in diameter; Dentalastics, Dentaurum), and a modified elastic ligature (Slide™; Leone(®)). Each combination was used with four archwires, including rectangular stainless steel (0.46 × 0.64 mm, 0.018 × 0.025″, Dentaurum), rectangular nickel-titanium with Teflon coating (0.46 × 0.64 mm, 0.018 × 0.025″, Forestadent(®)), round coaxial nickel-titanium (0.46 mm, 0.018″, Speed), and half-round/half-square (D-profile) stainless steel (0.46 mm, 0.018″, Speed). In the orthodontic measurement and simulation system (OMSS), retraction of a canine was simulated on a Frasaco model replicated in resin. Based on the force systems, the respective friction values were determined. For each combination of materials, five brackets of the same type were tested and five single measurements performed. Friction values were found to vary distinctly with the different combinations, modifiers being the ligature systems and the archwire types. Any significant friction differences between the steel-ligated, Slide™-ligated, and self-ligated brackets were sporadic. All three systems were associated with average friction values of 40 %. Active self-ligating brackets and elastic-ligated conventional brackets, by contrast, generally differed significantly from the three above-mentioned bracket systems and showed distinctly higher friction values averaging 59 and 67 %, respectively. While passive self-ligating bracket systems have frequently been touted as advantageous in the literature, they should not be regarded as the only favorable system. Steel-ligated and Slide™-ligated conventional bracket systems are capable of offering similar friction performance.

  7. Evaluation of the effect of three innovative recyling methods on the shear bond strength of stainless steel brackets-an in vitro study

    PubMed Central

    Kumar, Dilip; Palla, Aparna

    2017-01-01

    Background Orthodontists are commonly faced with the decision of what to do with debonded or inaccurately positioned brackets. An economical option to this dilemma is to recycle the brackets. Many recycling methods have been proposed, but the optimal bond strength of these recycled brackets needs further evaluation. Objectives: To evaluate and compare the effect of three recycling methods: (i) Sandblasting (ii) Sandblasting / direct flaming (iii) Sandblasting /direct flaming /acid bath solution on shear bond strength (SBS) of stainless steel brackets. Material and Methods Eighty human premolars were bonded with premolar stainless steel brackets as per manufacturer’s instructions. The teeth were divided into 4 groups (n=20): Recycling and initial debonding was not done in Control group (Group I). After initial bonding, the brackets in the rest of the three experimental groups were debonded and recycled by following methods: (i) Sandblasting (Group II) (ii) Sandblasting /direct flaming (Group III) (iii) Sandblasting /direct flaming /acid bath solution (Group IV). Further the recycled brackets were bonded. The specimens were then subjected to testing in a Universal machine. The evaluation of the variation of the shear bond strength (SBS) among test groups was done using one-way ANOVA test and inter-experimental group comparison was done by Newman-Keuls multiple post hoc procedure. Results Group I (8.6510±1.3943MPa) showed the highest bond strength followed by Group II (5.0185±0.9758MPa), Group IV (2.30±0.65MPa) and Group III (2.0455± 0.6196MPa). Statistically significant variations existed in the shear bond strength (SBS) in all groups analyzed except between Group III and Group IV. Conclusions The following conclusions were drawn from the study: 1. Shear bond strength of new brackets is significantly higher than the recycled brackets. 2. Brackets sandblasted with 90µm aluminium oxide particle air-abrasion showed significantly higher shear bond strength compared to direct flaming/sandblasting and direct flaming/sandblasting/acid bath solution. 3. Sandblasting with 90µm aluminium oxide particle air-abrasion is the simplest, most efficient and hence, the preferred method of recycling debonded brackets. Key words:Orthodontic bracket, recycling, shear bond strength. PMID:28469821

  8. Surface quality and microstructure of low-vacuum sintered orthodontic bracket 17-4 PH stainless steel fabricated by MIM process

    NASA Astrophysics Data System (ADS)

    Suharno, Bambang; Suharno, Lingga Pradinda; Saputro, Hantoro Restucondro; Irawan, Bambang; Prasetyadi, Tjokro; Ferdian, Deni; Supriyadi, Sugeng

    2018-02-01

    Surface roughness and microstructure play important role on orthodontic bracket quality. Therefore, orthodontic brackets need to have smooth surface roughness to reduce the friction and bacterial adhesion. Microstructure of orthodontic brackets also determine the mechanical properties and corrosion resistance. There are two methods to produce orthodontic bracket, investment casting and metal injection molding. The purpose of this study is to observe the surface roughness and microstructure of orthodontic bracket which were made from two different fabrication methods. To produce orthodontic bracket with metal injection molding method, 17-4 PH stainless steel feedstock was injected to the orthodontic bracket mold using injection molding machine. After injection, the binder was eliminated with solvent and thermal debinding. Solvent debinding process was conducted with hexane at 50 °C on magnetic stirrer for 1.5 hours. Thermal debinding process was conducted at 510 °C with 0.5 °C/min heat rate and 120 min holding time. Hereafter, sintering process were performed with vacuum tube furnace at 1360 °C with heat rate 5 °C/min and 90 min holding time in low vacuum atmosphere. To produce orthodontic bracket with investment casting method, the wax was injected into the mold then the wax pattern was arranged into the tree form. The tree form was then dipped into ceramic slurry and allowed to harden, the ceramic slurry has a thickness in the region of 10 mm. The ceramic mold was then heated at a temperature of over than 1100°C to strengthen the ceramic mold and to remove the remaining wax. After that, the molten 17-4 PH stainless steel was poured into the ceramic mold at a temperature of over 1600°C. The natural cooling process was carried out at temperature of 25°C, after which the ceramic mold was broken away. Then, the orthodontic bracket was cut from the tree form. The results show that the orthodontic bracket which were made with investment casting fabrication method have low porosity, high density, and there is no indication of secondary phase on the microstructure. However, it has rough brackets surface. Whereas, the production of orthodontic brackets using metal injection molding method resulted in better surface roughness. But, it has relatively high porosity, presence of another phase on the microstructure, and low density.

  9. Effect of archwire cross-section changes on force levels during complex tooth alignment with conventional and self-ligating brackets.

    PubMed

    Montasser, Mona A; Keilig, Ludger; El-Bialy, Tarek; Reimann, Susanne; Jäger, Andreas; Bourauel, Christoph

    2015-04-01

    Our objective was to investigate the effect of archwire cross-section increases on the levels of force applied to teeth during complex malalignment correction with various archwire-bracket combinations using an experimental biomechanical setup. The study comprised 3 types of orthodontic brackets: (1) conventional ligating brackets (Victory Series [3M Unitek, Monrovia, Calif] and Mini-Taurus [Rocky Mountain Orthodontics, Denver, Colo]), (2) self-ligating brackets (SmartClip, a passive self-ligating bracket [3M Unitek]; and Time3 [Rocky Mountain Orthodontics, Denver, Colo] and SPEED [Strite Industries, Cambridge, Ontario, Canada], both active self-ligating brackets), and (3) a conventional low-friction bracket (Synergy [Rocky Mountain Orthodontics]). All brackets had a nominal 0.022-in slot size. The brackets were combined with 0.014-in and 0.016-in titanium memory wires, Therma-Ti archwires (American Orthodontics, Sheboygan, Wis). The archwires were tied to the conventional brackets with both stainless steel ligatures of size 0.010-in and elastomeric rings. A malocclusion of the maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis) was simulated. The forces recorded when using the 0.014-in archwires ranged from 1.7 ± 0.1 to 5.0 ± 0.3 N in the x-axis direction, and from 1.2 ± 0.1 to 5.5 ± 0.3 N in the z-axis direction. When we used the 0.016-in archwires, the forces ranged from 2.6 ± 0.1 to 6.0 ± 0.3 N in the x-axis direction, and from 2.0 ± 0.2 to 6.0 ± 0.4 N in the z-axis direction. Overall, the increases ranged from 16.0% to 120.0% in the x-axis and from 10.4% to 130.0% in the z-axis directions. Increasing the cross section of the wire increased the force level invariably with all brackets. Wires of size 0.014 in produced relatively high force levels, and the force level increased with 0.016-in wires. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  10. Analysis of the characteristics of slot design affecting resistance to sliding during active archwire configurations

    PubMed Central

    2013-01-01

    Background During orthodontic treatment, a low resistance to slide (RS) is desirable when sliding mechanics are used. Many studies showed that several variables affect the RS at the bracket-wire interface; among these, the design of the bracket slot has not been deeply investigated yet. This study aimed to clarify the effect of different slot designs on the RS expressed by five types of low-friction brackets in vertical and horizontal active configurations of the wire. Methods Five low-friction brackets (Damon SL II, Ormco, Orange, CA, USA; In-Ovation, GAC International, Bohemia, NY, USA; Quick, Forestadent, Pforzheim, Germany; Time 2, AO, Sheboygan, WI, USA; Synergy, RMO, Denver, CO, USA) coupled with an 0.014-in NiTi thermal wire (Therma-Lite, AO) were tested in two three-bracket experimental models simulating vertical and horizontal bracket displacements. A custom-made machine was used to measure frictional resistance with tests repeated on ten occasions for each bracket-wire combination. Design characteristics such as the mesio-distal slot width, slot depth, and presence of chamfered edges at the extremities of the slot were evaluated on SEM images (SUPRA, Carl Zeiss, Oberkochen, Germany) and analyzed in relation to the data of RS recorded. Results Time 2 was found to show the higher frictional forces (1.50 and 1.35 N) in both experimental models (p < 0.05), while Quick and Synergy brackets showed the lower frictional values in the vertical (0.66 N) and in the horizontal (0.68 N) bracket displacements, respectively. With vertically displaced brackets, the increased mesio-distal slot width and the presence of clear angle at mesial and distal slot edges increase the values of RS. With brackets horizontally displaced, the RS expressed by the wire is influenced simultaneously by the depth of the slot, the mesio-distal slot width, and the presence of clear angle at the extremities of the slot base, the clip, or the slide. Conclusion In order to select the proper low-friction bracket system, clinicians should consider specific characteristics of slot design apart from the wire engaging method. PMID:24325837

  11. The effect of pre-cure bracket movement on shear bond strength during placement of orthodontic brackets, an in vitro study.

    PubMed

    Tam, Byron; Bollu, Prashanti; Chaudhry, Kishore; Subramani, Karthikeyan

    2017-10-01

    The purpose of this study was to determine the influence of linear and rotational pre-cure bracket displacement during the bonding procedure on shear bond strength (SBS) of orthodontic brackets. Stainless steel orthodontic premolar brackets were bonded to the buccal surfaces of 50 human pre-molars with a conventional two-step bonding protocol. Extracted human pre-molars were divided into 5 groups (n=10/group). In the Control Group, the brackets were bonded with no pre-cure bracket displacement or rotation. The Rotation Group was bonded with 45 degrees of pre-cure rotation. The Displacement Group was bonded with 2mm pre-cure linear displacement. The Rotation-Displacement Group was bonded with pre-cure movements of 45º counter-clockwise rotation and 2mm displacement. The Slippage Group was bonded with 2mm each of mesial and distal pre-cure linear displacement. Photo-activation was carried out on the lateral sides of the bracket. Shear debonding force was measured, 24 hours after initial bonding, with an Instron universal testing machine using a knife-edged chisel. Data was analyzed using one-way ANOVA test. Adhesive Remnant Index (ARI) was scored under 15x magnification. The ARI data was analyzed using the Chi-square test ( p -value < 0.05). No statistically significant differences were detected among the control and experimental groups ( p = 0.331). The rotation and displacement group showed the highest mean SBS than all other groups. Mean SBS for all groups were above the clinically acceptable range. No statistically significant differences were detected in ARI scores among groups ( p = 0.071). Linear and rotational pre-cure bracket displacements do not appear to effect the shear bond strength of orthodontic brackets. Key words: Shear bond strength, orthodontic bracket, displacement, rotation, adhesive remnant index, pre-cure movement.

  12. Complexity of Kronecker Operations on Sparse Matrices with Applications to the Solution of Markov Models

    NASA Technical Reports Server (NTRS)

    Buchholz, Peter; Ciardo, Gianfranco; Donatelli, Susanna; Kemper, Peter

    1997-01-01

    We present a systematic discussion of algorithms to multiply a vector by a matrix expressed as the Kronecker product of sparse matrices, extending previous work in a unified notational framework. Then, we use our results to define new algorithms for the solution of large structured Markov models. In addition to a comprehensive overview of existing approaches, we give new results with respect to: (1) managing certain types of state-dependent behavior without incurring extra cost; (2) supporting both Jacobi-style and Gauss-Seidel-style methods by appropriate multiplication algorithms; (3) speeding up algorithms that consider probability vectors of size equal to the "actual" state space instead of the "potential" state space.

  13. African Oral Tradition Literacy.

    ERIC Educational Resources Information Center

    Green, Doris

    1985-01-01

    Presents the basic principles of two systems for notating African music and dance: Labanotation (created to record and analyze movements) and Greenotation (created to notate musical instruments of Africa and to parallel Labanotation whereby both music and dance are incorporated into one integrated score). (KH)

  14. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  15. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  16. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  17. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  18. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  19. Assurance Arguments for the Non-Graphically-Inclined: Two Approaches

    NASA Technical Reports Server (NTRS)

    Heavner, Emily; Holloway, C. Michael

    2017-01-01

    We introduce and discuss two approaches to presenting assurance arguments. One approach is based on a monograph structure, while the other is based on a tabular structure. In today's research and academic setting, assurance cases often use a graphical notation; however for people who are not graphically inclined, these notations can be difficult to read. This document proposes, outlines, explains, and presents examples of two non-graphical assurance argument notations that may be appropriate for non-graphically-inclined readers and also provide argument writers with freedom to add details and manipulate an argument in multiple ways.

  20. The SNARC Effect in Chinese Numerals: Do Visual Properties of Characters and Hand Signs Influence Number Processing?

    PubMed Central

    Löwenkamp, Christian; Eloka, Owino; Schiller, Florian; Kao, Chung-Shan; Wu, Chaohua; Gao, Xiaorong; Franz, Volker H.

    2016-01-01

    The SNARC effect refers to an association of numbers and spatial properties of responses that is commonly thought to be amodal and independent of stimulus notation. We tested for a horizontal SNARC effect using Arabic digits, simple-form Chinese characters and Chinese hand signs in participants from Mainland China. We found a horizontal SNARC effect in all notations. This is the first time that a horizontal SNARC effect has been demonstrated in Chinese characters and Chinese hand signs. We tested for the SNARC effect in two experiments (parity judgement and magnitude judgement). The parity judgement task yielded clear, consistent SNARC effects in all notations, whereas results were more mixed in magnitude judgement. Both Chinese characters and Chinese hand signs are represented non-symbolically for low numbers and symbolically for higher numbers, allowing us to contrast within the same notation the effects of heavily learned non-symbolic vs. symbolic representation on the processing of numbers. In addition to finding a horizontal SNARC effect, we also found a robust numerical distance effect in all notations. This is particularly interesting as it persisted when participants reported using purely visual features to solve the task, thereby suggesting that numbers were processed semantically even when the task could be solved without the semantic information. PMID:27684956

  1. Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods

    PubMed Central

    Alavi, Shiva; Kachuie, Marzie

    2017-01-01

    Background: This study was conducted to assess the hardness of orthodontic brackets produced by metal injection molding (MIM) and conventional methods and different orthodontic wires (stainless steel, nickel-titanium [Ni-Ti], and beta-titanium alloys) for better clinical results. Materials and Methods: A total of 15 specimens from each brand of orthodontic brackets and wires were examined. The brackets (Elite Opti-Mim which is produced by MIM process and Ultratrimm which is produced by conventional brazing method) and the wires (stainless steel, Ni-Ti, and beta-titanium) were embedded in epoxy resin, followed by grinding, polishing, and coating. Then, X-ray energy dispersive spectroscopy (EDS) microanalysis was applied to assess their elemental composition. The same specimen surfaces were repolished and used for Vickers microhardness assessment. Hardness was statistically analyzed with Kruskal–Wallis test, followed by Mann–Whitney test at the 0.05 level of significance. Results: The X-ray EDS analysis revealed different ferrous or co-based alloys in each bracket. The maximum mean hardness values of the wires were achieved for stainless steel (SS) (529.85 Vickers hardness [VHN]) versus the minimum values for beta-titanium (334.65 VHN). Among the brackets, Elite Opti-Mim exhibited significantly higher VHN values (262.66 VHN) compared to Ultratrimm (206.59 VHN). VHN values of wire alloys were significantly higher than those of the brackets. Conclusion: MIM orthodontic brackets exhibited hardness values much lower than those of SS orthodontic archwires and were more compatible with NiTi and beta-titanium archwires. A wide range of microhardness values has been reported for conventional orthodontic brackets and it should be considered that the manufacturing method might be only one of the factors affecting the mechanical properties of orthodontic brackets including hardness. PMID:28928783

  2. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging.

    PubMed

    Dalili Kajan, Zahra; Khademi, Jalil; Alizadeh, Ahmad; Babaei Hemmaty, Yasamin; Atrkar Roushan, Zahra

    2015-09-01

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1 -weighted images, fast spin-echo T2 -weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

  3. Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods.

    PubMed

    Alavi, Shiva; Kachuie, Marzie

    2017-01-01

    This study was conducted to assess the hardness of orthodontic brackets produced by metal injection molding (MIM) and conventional methods and different orthodontic wires (stainless steel, nickel-titanium [Ni-Ti], and beta-titanium alloys) for better clinical results. A total of 15 specimens from each brand of orthodontic brackets and wires were examined. The brackets (Elite Opti-Mim which is produced by MIM process and Ultratrimm which is produced by conventional brazing method) and the wires (stainless steel, Ni-Ti, and beta-titanium) were embedded in epoxy resin, followed by grinding, polishing, and coating. Then, X-ray energy dispersive spectroscopy (EDS) microanalysis was applied to assess their elemental composition. The same specimen surfaces were repolished and used for Vickers microhardness assessment. Hardness was statistically analyzed with Kruskal-Wallis test, followed by Mann-Whitney test at the 0.05 level of significance. The X-ray EDS analysis revealed different ferrous or co-based alloys in each bracket. The maximum mean hardness values of the wires were achieved for stainless steel (SS) (529.85 Vickers hardness [VHN]) versus the minimum values for beta-titanium (334.65 VHN). Among the brackets, Elite Opti-Mim exhibited significantly higher VHN values (262.66 VHN) compared to Ultratrimm (206.59 VHN). VHN values of wire alloys were significantly higher than those of the brackets. MIM orthodontic brackets exhibited hardness values much lower than those of SS orthodontic archwires and were more compatible with NiTi and beta-titanium archwires. A wide range of microhardness values has been reported for conventional orthodontic brackets and it should be considered that the manufacturing method might be only one of the factors affecting the mechanical properties of orthodontic brackets including hardness.

  4. Gingival crevicular fluid volume and periodontal parameters alterations after use of conventional and self-ligating brackets.

    PubMed

    Bergamo, Ana Zn; Nelson-Filho, Paulo; Romano, Fábio L; da Silva, Raquel Ab; Saraiva, Maria Cp; da Silva, Lea Ab; Matsumoto, Mirian An

    2016-12-01

    The aim of this study was to evaluate the alterations on plaque index (PI), gingival index (GI), gingival bleeding index (GBI), and gingival crevicular fluid (GCF) volume after use of three different brackets types for 60 days. Setting Participants: The sample comprised 20 patients of both sexes aged 11-15 years (mean age: 13.3 years), with permanent dentition, adequate oral hygiene, and mild tooth crowding, overjet, and overbite. A conventional metallic bracket Gemini™, and two different brands of self-ligating brackets - In-Ovation ® R and SmartClip™ - were bonded to the maxillary incisors and canines. PI, GI, GBI scores, and GCF volume were measured before and 30 and 60 days after bonding of the brackets. Data were analysed statistically using non-parametric tests coefficient at a 5% significance level. There was no statistically significant correlation (P > 0.05) between tooth crowding, overjet, and overbite and the PI, GI, GBI scores, and GCF volume before bonding, indicating no influence of malocclusion on the clinical parameters. Regardless of the bracket design, no statistically significant difference (P > 0.05) was found for GI, GBI scores. PI and GCF volume showed a significant difference among the brackets in different periods. In pairwise comparisons a significant difference was observed when compared before with 60 days after bonding, for the teeth bonded with SmartClip™ self-ligating bracket, (PI P = 0.009; GCF volume P = 0.001). There was an increase in PI score and GCF volume 60 days after bonding of SmartClip™ self-ligating brackets, indicating the influence of bracket design on these clinical parameters.

  5. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

    PubMed Central

    Khademi, Jalil; Alizadeh, Ahmad; Babaei Hemmaty, Yasamin; Atrkar Roushan, Zahra

    2015-01-01

    Purpose This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Materials and Methods A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Results Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. Conclusion With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires. PMID:26389058

  6. Accuracy of four different digital intraoral scanners: effects of the presence of orthodontic brackets and wire.

    PubMed

    Jung, Yoo-Ran; Park, Ji-Man; Chun, Youn-Sic; Lee, Kkot-Nim; Kim, Minji

    The objective of this study was to compare the accuracy of four different digital intraoral scanners and the effects of buccal brackets and orthodontic wire. For this study, three sets of models (Control model, BKT model with buccal bracket, and WBKT model with buccal bracket and orthodontic wire) were scanned using four different types of intraoral scanners: E4D dentist, iTero, Trios, and Zfx IntraScan. The mesiodistal width of the teeth, intercanine width, and intermolar width measured by four scanners were compared. Three-dimensional (3D) images of the brackets were taken using the four scanners. Data were analyzed with one-way ANOVA, independent t test, and post-hoc Tukey test at a significance level of P < 0.05. When comparing the 3D images with manual measurements using a traditional caliper, iTero and Trios showed the highest accuracy in horizontal measurements.iTero had the lowest values in Devmax-min of maxillary intermolar and intercanine widths (0.16 mm and 0.20 mm, respectively), whereas Trios had the lowest values in Devmax-min of mandibular intermolar and intercanine widths (0.36 mm and 0.14 mm, respectively). The horizontal variables were barely affected by the presence of buccal brackets and orthodontic wire. Comparison of 3D bracket images scanned by the four scanners showed differences in image distortion among the scanners. Bracket characteristics did not affect the 3D bracket images. The four intraoral scanners used in this study differed in accuracy. However, the results acquired by iTero and Trios were more reliable. Effects of buccal brackets and orthodontic wire on the 3D images taken by intraoral scanners were not clinically significant.

  7. Electrothermal debonding of ceramic brackets. An in vitro study.

    PubMed

    Brouns, E M; Schopf, P M; Kocjancic, B

    1993-04-01

    Two different kinds of devices for electrothermal debonding of ceramic brackets are evaluated. Thirty human premolars were bonded with two types of ceramic brackets. Both devices were tested for electrothermal removal of the two bracket types. The pulpal wall temperature increase during electrothermal debonding was recorded in vitro under various circumstances. After debonding, the fracture site was located. The data were compared to the temperature rise after simulated exposure of the teeth to warm beverages. Irreversible pulp damage due to electrothermal debonding of ceramic brackets with both instruments is not to be expected because the obtained results stayed below established primate threshold temperatures and significantly below that of the stimulated control groups. A significant difference was noted when air cooling was initiated during electrothermal debonding. Fracture site location was significantly different in the two ceramic bracket types after electrothermal debonding.

  8. Liquid crystalline epoxy nanocomposite material for dental application.

    PubMed

    Tai, Yun-Yuan; Hsu, Sheng-Hao; Chen, Rung-Shu; Su, Wei-Fang; Chen, Min-Huey

    2015-01-01

    Novel liquid crystalline epoxy nanocomposites, which exhibit reduced polymerization shrinkage and effectively bond to tooth structures, can be applied in esthetic dentistry, including core and post systems, direct and indirect restorations, and dental brackets. The purposes of this study were to investigate the properties of liquid crystalline epoxy nanocomposites including biocompatibility, microhardness, and frictional forces of bracket-like blocks with different filler contents for further clinical applications. In this study, we evaluated liquid crystalline epoxy nanocomposite materials that exhibited various filler contents, by assessing their cell activity performance using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay and their microhardness with or without thermocycling. We also evaluated the frictional force between bracket-like duplicates and commercially available esthetic bracket systems using Instron 5566. The liquid crystalline epoxy nanocomposite materials showed good biocompatibility. The materials having high filler content demonstrated greater microhardness compared with commercially available bracket materials, before and after the thermocycling treatment. Thus, manufacturing processes are important to reduce frictional force experienced by orthodontic brackets. The microhardness of the bracket-like blocks made by our new material is superior to the commercially available brackets, even after thermocycling. Our results indicate that the evaluated liquid crystalline epoxy nanocomposite materials are of an appropriate quality for application in dental core and post systems and in various restorations. By applying technology to refine manufacturing processes, these new materials could also be used to fabricate esthetic brackets for orthodontic treatment. Copyright © 2014. Published by Elsevier B.V.

  9. Comparative evaluation of nickel discharge from brackets in artificial saliva at different time intervals.

    PubMed

    Jithesh, C; Venkataramana, V; Penumatsa, Narendravarma; Reddy, S N; Poornima, K Y; Rajasigamani, K

    2015-08-01

    To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable.

  10. Comparative evaluation of nickel discharge from brackets in artificial saliva at different time intervals

    PubMed Central

    Jithesh, C.; Venkataramana, V.; Penumatsa, Narendravarma; Reddy, S. N.; Poornima, K. Y.; Rajasigamani, K.

    2015-01-01

    Objectives: To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Materials and Methods: Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. Result: The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. Conclusion: The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable. PMID:26538924

  11. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    PubMed Central

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film. PMID:28902253

  12. Clinical and microbiological parameters in patients with self-ligating and conventional brackets during early phase of orthodontic treatment.

    PubMed

    Pejda, Slavica; Varga, Marina Lapter; Milosevic, Sandra Anic; Mestrovic, Senka; Slaj, Martina; Repic, Dario; Bosnjak, Andrija

    2013-01-01

    To determine the effect of different bracket designs (conventional brackets and self-ligating brackets) on periodontal clinical parameters and periodontal pathogens in subgingival plaque. The following inclusion criteria were used: requirement of orthodontic treatment plan starting with alignment and leveling, good general health, healthy periodontium, no antibiotic therapy in the previous 6 months before the beginning of the study, and no smoking. The study sample totaled 38 patients (13 male, 25 female; mean age, 14.6 ± 2.0 years). Patients were divided into two groups with random distribution of brackets. Recording of clinical parameters was done before the placement of the orthodontic appliance (T0) and at 6 weeks (T1), 12 weeks (T2), and 18 weeks (T3) after full bonding of orthodontic appliances. Periodontal pathogens of subgingival microflora were detected at T3 using a commercially available polymerase chain reaction test (micro-Dent test) that contains probes for Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, and Treponema denticola. There was a statistically significant higher prevalence of A actinomycetemcomitans in patients with conventional brackets than in patients with self-ligating brackets, but there was no statistically significant difference for other putative periodontal pathogens. The two different types of brackets did not show statistically significant differences in periodontal clinical parameters. Bracket design does not seem to have a strong influence on periodontal clinical parameters and periodontal pathogens in subgingival plaque. The correlation between some periodontal pathogens and clinical periodontal parameters was weak.

  13. Split-tapered joint clamping device

    DOEpatents

    Olsen, Max J.; Schwartz, Jr., John F.

    1988-01-01

    This invention relates to a clamping device for removably attaching a tool element to a bracket element wherein a bracket element is disposed in a groove in the tool and a clamping member is disposed in said groove and in engagement with a clamping face of the bracket and a wall of the groove and with the clamping member having pivot means engaging the bracket and about which the clamping member rotates.

  14. An in vitro comparison of nickel and chromium release from brackets.

    PubMed

    Haddad, Ana Cristina Soares Santos; Tortamano, Andre; Souza, Alexandre Luís de; Oliveira, Pedro Vitoriano de

    2009-01-01

    This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37 degrees Celsius. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (microg L(-1) per week) varied between groups from 'bellow detection limits' to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (microg L(-1) per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.

  15. In vitro evaluation of corrosion and cytotoxicity of orthodontic brackets.

    PubMed

    Costa, M T; Lenza, M A; Gosch, C S; Costa, I; Ribeiro-Dias, F

    2007-05-01

    The corrosion resistance of AISI 304 stainless steel (AISI 304 SS) and manganese stainless steel (low-nickel SS) brackets in artificial saliva was investigated. The cytotoxic effects of their corrosion products on L929 cell culture were compared by two assays, crystal violet, to evaluate cell viability, and MTT (3-[4,5-dimethylthiazol-2-yl]2,5-diphenyltetrazolium bromide), for cell metabolism and proliferation. The atomic absorption spectroscopic analysis of the corrosion products demonstrated that nickel and manganese ion concentrations were higher for the AISI 304 SS-bracket immersion solution as compared with the low-nickel SS brackets. Scanning electron microscopy and energy-dispersive spectroscopy demonstrated less corrosion resistance for the AISI 304 SS brackets. Although none of the bracket extracts altered L929 cell viability or morphology, the AISI 304 SS-bracket extracts decreased cellular metabolism slightly. The results indicated that the low-nickel SS presents better in vitro biocompatibility than AISI 304 SS brackets. Abbreviations used: AISI, American Iron and Steel Institute; EDS, energy-dispersive spectroscopy; OD, optical density; ISO, International Organization for Standardization; MTT, (3-{4,5 dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide; NiSO(4), nickel sulfate; SEM, standard error of the mean; WHO, World Health Organization; and TNF, tumor necrosis factor.

  16. Assessment of antibacterial and cytotoxic effects of orthodontic stainless steel brackets coated with different phases of titanium oxide: An in-vitro study.

    PubMed

    Baby, Roshen Daniel; Subramaniam, Siva; Arumugam, Ilakkiya; Padmanabhan, Sridevi

    2017-04-01

    Our objective was to assess the antibacterial and cytotoxic effects of orthodontic stainless steel brackets coated with different phases of photocatalytic titanium oxide. From a total sample of 115 brackets, 68 orthodontic stainless steel brackets were coated with titanium oxide using a radiofrequency magnetron sputtering machine. The coated brackets were then converted into 34 each of the anatase and rutile phases of titanium oxide. These brackets were subdivided into 4 groups for antibacterial study and 3 groups for cytotoxicity study. Brackets for the antibacterial study were assessed against the Streptococcus mutans species using microbiologic tests. Three groups for the cytotoxicity study were assessed using the thiazolyl tetrazolium bromide assay. The antibacterial study showed that both phases were effective, but the rutile phase of photocatalytic titanium oxide had a greater bactericidal effect than did the anatase phase. The cytotoxicity study showed that the rutile phase had a greater decrease in viability of cells compared with the anatase phase. It is recommended that orthodontic brackets be coated with the anatase phase of titanium oxide since they exhibited a significant antibacterial property and were only slightly cytotoxic. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. Effect of blood contamination on shear bond strength of orthodontic brackets and disinclusion buttons.

    PubMed

    Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea

    2011-07-01

    Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Electrothermal debracketing: patient acceptance and effects on the dental pulp.

    PubMed

    Dovgan, J S; Walton, R E; Bishara, S E

    1995-09-01

    Adhesives bond ceramic brackets so effectively that their removal by mechanical forces can fracture the brackets and may damage the tooth surface. Electrothermal debracketers have been developed to facilitate removal; whether the heat generated will damage the underlying pulp is unclear. In our experiment, a prototype device with a high heat tip was used to remove brackets from premolars in patients. The following parameters were evaluated: (1) time required for removal, (2) patient acceptance, and (3) histologic effect on the pulp. Forty-eight experimental teeth planned for orthodontic extraction were bonded by a filled Bis-GMA composite resin and a monocrystalline sapphire bracket. After the chemically cured composite set, debracketing was performed according to the manufacturer's recommendations. Seventeen premolars were not etched or bracketed and served as controls. The interval between heat application and removal of the bracket was timed. Patients were questioned as to sensations during debracketing. Teeth were extracted at 5 to 7 or 28 to 32 days and histologically prepared. Pulps were evaluated for alterations. Brackets were removed in an average of 2.1 seconds, usually at the bracket/composite interface. Patient acceptance was generally positive. Pulpal necrosis was not observed but, in a number of specimens, slight inflammation and odontoblastic disruption occurred at both observation periods.

  19. Bracket for photovoltaic modules

    DOEpatents

    Ciasulli, John; Jones, Jason

    2014-06-24

    Brackets for photovoltaic ("PV") modules are described. In one embodiment, a saddle bracket has a mounting surface to support one or more PV modules over a tube, a gusset coupled to the mounting surface, and a mounting feature coupled to the gusset to couple to the tube. The gusset can have a first leg and a second leg extending at an angle relative to the mounting surface. Saddle brackets can be coupled to a torque tube at predetermined locations. PV modules can be coupled to the saddle brackets. The mounting feature can be coupled to the first gusset and configured to stand the one or more PV modules off the tube.

  20. The Misuse of the Circle Notation to Represent Aromatic Rings.

    ERIC Educational Resources Information Center

    Belloli, Robert C.

    1983-01-01

    Discusses the confusion and erroneous conclusions that can result from the overuse and misuse of the circle notation to represent aromaticity in polycylic aromatic hydrocarbons. Includes nature of the problem, textbook treatment, and a possible compromise method of representation. (Author/JN)

  1. Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets

    PubMed Central

    Major, Thomas W.; Carey, Jason P.; Nobes, David S.; Major, Paul W.

    2010-01-01

    In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized. PMID:20981299

  2. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    PubMed

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  3. Preparation of an orthodontic bracket coated with an nitrogen-doped TiO(2-x)N(y) thin film and examination of its antimicrobial performance.

    PubMed

    Cao, Baocheng; Wang, Yuhua; Li, Na; Liu, Bin; Zhang, Yingjie

    2013-01-01

    A bracket coated with a nitrogen-doped (N-doped) TiO(2-x)N(y) thin film was prepared using the RF magnetron sputtering method. The physicochemical properties of the thin film were measured using X-ray diffraction and energy-dispersive X-ray spectrometry, while the antimicrobial activity of the bracket against common oral pathogenic microbes was assessed on the basis of colony counts. The rate of antimicrobial activity of the bracket coated with nano-TiO(2-x)N(y) thin film against Streptococcus mutans, Lactobacillus acidophilus, Actinomyces viscous, and Candida albicans was 95.19%, 91.00%, 69.44%, and 98.86%, respectively. Scanning electron microscopy showed that fewer microbes adhered to the surface of this newly designed bracket than to the surface of the normal edgewise bracket. The brackets coated with the N-doped TiO(2-x)N(y) thin film showed high antimicrobial and bacterial adhesive properties against normal oral pathogenic bacterial through visible light, which is effective in prevention of enamel demineralization and gingivitis in orthodontic patients.

  4. Process qualification and testing of LENS deposited AY1E0125 D-bottle brackets.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atwood, Clinton J.; Smugeresky, John E.; Jew, Michael

    2006-11-01

    The LENS Qualification team had the goal of performing a process qualification for the Laser Engineered Net Shaping{trademark}(LENS{reg_sign}) process. Process Qualification requires that a part be selected for process demonstration. The AY1E0125 D-Bottle Bracket from the W80-3 was selected for this work. The repeatability of the LENS process was baselined to determine process parameters. Six D-Bottle brackets were deposited using LENS, machined to final dimensions, and tested in comparison to conventionally processed brackets. The tests, taken from ES1E0003, included a mass analysis and structural dynamic testing including free-free and assembly-level modal tests, and Haversine shock tests. The LENS brackets performedmore » with very similar characteristics to the conventionally processed brackets. Based on the results of the testing, it was concluded that the performance of the brackets made them eligible for parallel path testing in subsystem level tests. The testing results and process rigor qualified the LENS process as detailed in EER200638525A.« less

  5. Abstract numeric relations and the visual structure of algebra.

    PubMed

    Landy, David; Brookes, David; Smout, Ryan

    2014-09-01

    Formal algebras are among the most powerful and general mechanisms for expressing quantitative relational statements; yet, even university engineering students, who are relatively proficient with algebraic manipulation, struggle with and often fail to correctly deploy basic aspects of algebraic notation (Clement, 1982). In the cognitive tradition, it has often been assumed that skilled users of these formalisms treat situations in terms of semantic properties encoded in an abstract syntax that governs the use of notation without particular regard to the details of the physical structure of the equation itself (Anderson, 2005; Hegarty, Mayer, & Monk, 1995). We explore how the notational structure of verbal descriptions or algebraic equations (e.g., the spatial proximity of certain words or the visual alignment of numbers and symbols in an equation) plays a role in the process of interpreting or constructing symbolic equations. We propose in particular that construction processes involve an alignment of notational structures across representation systems, biasing reasoners toward the selection of formal notations that maintain the visuospatial structure of source representations. For example, in the statement "There are 5 elephants for every 3 rhinoceroses," the spatial proximity of 5 and elephants and 3 and rhinoceroses will bias reasoners to write the incorrect expression 5E = 3R, because that expression maintains the spatial relationships encoded in the source representation. In 3 experiments, participants constructed equations with given structure, based on story problems with a variety of phrasings. We demonstrate how the notational alignment approach accounts naturally for a variety of previously reported phenomena in equation construction and successfully predicts error patterns that are not accounted for by prior explanations, such as the left to right transcription heuristic.

  6. 19 CFR 208.6 - Service, filing, and certification of documents.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... confidential business information in brackets and have the following warning marked on every page: “Bracketing... version of the document is due to be filed. If the submitter discovers it has failed to bracket correctly...

  7. [Self-ligating edgewise brackets. An overview].

    PubMed

    Katsaros, C; Dijkman, J F

    2003-01-01

    During the last years both the manufactures and the orthodontists seem to show an increased interest in self-ligating brackets. This paper aims to present the history of self-ligating systems, to describe the three mostly used bracketsystems and to review the relevant literature. It seems from the existing data that self-ligating brackets have certain advantages over conventionally ligated brackets. However, the data are still thin and a high need for well designed clinical trials exist.

  8. 19 CFR 141.90 - Notation of tariff classification and value on invoice.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... (d) Importer's notations in blue or black ink. Except when invoice line data are linked to an entry... the invoice by the importer or customs broker must be in blue or black ink. [T.D. 73-175, 38 FR 17447...

  9. 19 CFR 141.90 - Notation of tariff classification and value on invoice.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... (d) Importer's notations in blue or black ink. Except when invoice line data are linked to an entry... the invoice by the importer or customs broker must be in blue or black ink. [T.D. 73-175, 38 FR 17447...

  10. 19 CFR 141.90 - Notation of tariff classification and value on invoice.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (d) Importer's notations in blue or black ink. Except when invoice line data are linked to an entry... the invoice by the importer or customs broker must be in blue or black ink. [T.D. 73-175, 38 FR 17447...

  11. 19 CFR 141.90 - Notation of tariff classification and value on invoice.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... (d) Importer's notations in blue or black ink. Except when invoice line data are linked to an entry... the invoice by the importer or customs broker must be in blue or black ink. [T.D. 73-175, 38 FR 17447...

  12. 7 CFR 27.69 - Classification review; notations on certificate.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... review of classification is made after the issuance of a cotton class certificate, the results of the... 7 Agriculture 2 2011-01-01 2011-01-01 false Classification review; notations on certificate. 27.69... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Classification...

  13. Japanese Children's Understanding of Notational Systems

    ERIC Educational Resources Information Center

    Takahashi, Noboru

    2012-01-01

    This study examined Japanese children's understanding of two Japanese notational systems: "hiragana" and "kanji". In three experiments, 126 3- to 6-year-olds were asked to name words written in hiragana or kanji as they appeared with different pictures. Consistent with Bialystok ("Journal of Experimental Child…

  14. Solving Constraint-Satisfaction Problems In Prolog Language

    NASA Technical Reports Server (NTRS)

    Nachtsheim, Philip R.

    1991-01-01

    Technique for solution of constraint-satisfaction problems uses definite-clause grammars of Prolog computer language. Exploits fact that grammar-rule notation viewed as "state-change notation". Facilitates development of dynamic representation performing informed as well as blind searches. Applicable to design, scheduling, and planning problems.

  15. A Formal Messaging Notation for Alaskan Aviation Data

    NASA Technical Reports Server (NTRS)

    Rios, Joseph L.

    2015-01-01

    Data exchange is an increasingly important aspect of the National Airspace System. While many data communication channels have become more capable of sending and receiving data at higher throughput rates, there is still a need to use communication channels efficiently with limited throughput. The limitation can be based on technological issues, financial considerations, or both. This paper provides a complete description of several important aviation weather data in Abstract Syntax Notation format. By doing so, data providers can take advantage of Abstract Syntax Notation's ability to encode data in a highly compressed format. When data such as pilot weather reports, surface weather observations, and various weather predictions are compressed in such a manner, it allows for the efficient use of throughput-limited communication channels. This paper provides details on the Abstract Syntax Notation One (ASN.1) implementation for Alaskan aviation data, and demonstrates its use on real-world aviation weather data samples as Alaska has sparse terrestrial data infrastructure and data are often sent via relatively costly satellite channels.

  16. Boundary-layer equations in generalized curvilinear coordinates

    NASA Technical Reports Server (NTRS)

    Panaras, Argyris G.

    1987-01-01

    A set of higher-order boundary-layer equations is derived valid for three-dimensional compressible flows. The equations are written in a generalized curvilinear coordinate system, in which the surface coordinates are nonorthogonal; the third axis is restricted to be normal to the surface. Also, higher-order viscous terms which are retained depend on the surface curvature of the body. Thus, the equations are suitable for the calculation of the boundary layer about arbitrary vehicles. As a starting point, the Navier-Stokes equations are derived in a tensorian notation. Then by means of an order-of-magnitude analysis, the boundary-layer equations are developed. To provide an interface between the analytical partial differentiation notation and the compact tensor notation, a brief review of the most essential theorems of the tensor analysis related to the equations of the fluid dynamics is given. Many useful quantities, such as the contravariant and the covariant metrics and the physical velocity components, are written in both notations.

  17. A clocking discipline for two-phase digital integrated circuits

    NASA Astrophysics Data System (ADS)

    Noice, D. C.

    1983-09-01

    Sooner or later a designer of digital circuits must face the problem of timing verification so he can avoid errors caused by clock skew, critical races, and hazards. Unlike previous verification methods, such as timing simulation and timing analysis, the approach presented here guarantees correct operation despite uncertainty about delays in the circuit. The result is a clocking discipline that deals with timing abstractions only. It is not based on delay calculations; it is only concerned with the correct, synchronous operation at some clock rate. Accordingly, it may be used earlier in the design cycle, which is particularly important to integrated circuit designs. The clocking discipline consists of a notation of clocking types, and composition rules for using the types. Together, the notation and rules define a formal theory of two phase clocking. The notation defines the names and exact characteristics for different signals that are used in a two phase digital system. The notation makes it possible to develop rules for propagating the clocking types through particular circuits.

  18. Biocompatibility of nanosilver-coated orthodontic brackets: an in vivo study.

    PubMed

    Metin-Gürsoy, Gamze; Taner, Lale; Barış, Emre

    2016-12-01

    Nanosilver particles of which antibacterial and antifungal properties have been shown in various in vitro and in vivo studies are used in many medical and dental fields for the prevention of infection. In this study, it is intended to evaluate the biocompatibility of nanosilver-coated brackets. Nanosilver coating process was applied to the standard orthodontic brackets by a physical vapor deposition system. Brackets were coated with nanosilver particles of 1 μ thickness. A total of 12 Wistar Albino rats were included in the study (six) and control (six) groups. For the study and control groups, four nanosilver-coated and four standard brackets were aseptically implanted subcutaneously in the dorsal region of each rat. The brackets were removed with the surrounding tissues on days 7, 14, 30, and 60. The specimens were evaluated for inflammatory response. No significant difference was found in terms of tissue reaction between the study and control groups. On day 7, randomly distributed brown-black granules were seen in the granulation tissue adjacent to the bracket in the study group. These foreign particles continued along the bracket cavity in a few samples, but the inflammatory response was insignificant between the groups. Mast cell count was found to be significantly smaller only on day 7 in the study group than in the control group. Nanosilver-coated orthodontic brackets were found to be similar with the standard type concerning inflammation. Further researches are needed with regard to the assessment of the brown-black granules, especially on the deposition of the vessel walls.

  19. Biomechanical characteristics of self-ligating brackets in a vertically displaced canine model: a finite element analysis.

    PubMed

    Kim, S-J; Kwon, Y-H; Hwang, C-J

    2016-05-01

    The objective of this study was to compare the biomechanical characteristics between two types of self-ligating brackets and conventional metal brackets using finite element analysis of a vertically displaced canine model focusing on the desired force on the canine and undesirable forces on adjacent teeth. Three-dimensional finite element models of the maxillary dentition with 1-mm, 2-mm, and 3-mm vertically displaced canines were constructed. Two different self-ligating brackets (In-Ovation C and Smart clip) and a conventional metal bracket (Micro-arch) were modeled. After a 0.016-inch NiTi (0.40 mm, round) wire was engaged, the displacement of each tooth was calculated using x-, y-, and z-coordinates, and the tensile and compressive stresses were calculated. The extrusion and maximal tensile stress of the canine differed little between the three brackets, but the intrusion and minimal compressive stress values of the adjacent teeth differed considerably and were highest in the Smart clip and least in the In-Ovation C. The extrusion and maximal tensile stress of the canine in the 3-mm displacement model was less than that in the 2-mm displacement model, and the intrusion and minimal compressive stress of the adjacent teeth increased with the degree of displacement. Self-ligating brackets were not superior to conventional brackets in leveling a vertically displaced canine. A continuous arch wire may not be recommended for leveling of severely displaced canines whether using self-ligating or conventional brackets. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Effects of silica coating and silane surface conditioning on the bond strength of rebonded metal and ceramic brackets.

    PubMed

    Atsü, Saadet; Çatalbaş, Bülent; Gelgör, İbrahim Erhan

    2011-01-01

    The aim of this study was to evaluate the effects of tribochemical silica coating and silane surface conditioning on the bond strength of rebonded metal and ceramic brackets. Twenty debonded metal and 20 debonded ceramic brackets were randomly assigned to receive one of the following surface treatments (n=10 for each group): (1) sandblasting (control); (2) tribochemical silica coating combined with silane. Brackets were rebonded to the enamel surface on the labial and lingual sides of premolars with a light-polymerized resin composite. All specimens were stored in distilled water for 1 week and then thermocycled (5,000 cycles) between 5-55ºC. Shear bond strength values were measured using a universal testing machine. Student's t-test was used to compare the data (α=0.05). Failure mode was assessed using a stereomicroscope, and the treated and non-treated bracket surfaces were observed by scanning electron microscopy. Rebonded ceramic brackets treated with silica coating followed by silanization had significantly greater bond strength values (17.7±4.4 MPa) than the sandblasting group (2.4±0.8 MPa, P<0.001). No significant difference was observed between the rebonded metal brackets treated with silica coating with silanization (15±3.9 MPa) and the sandblasted brackets (13.6±3.9 MPa). Treated rebonded ceramic specimens primarily exhibited cohesive failure in resin and adhesive failure at the enamel-adhesive interface. In comparison to sandblasting, silica coating with aluminum trioxide particles followed by silanization resulted in higher bond strengths of rebonded ceramic brackets.

  1. Interior view, detail to show typical bracket with gold leaf ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view, detail to show typical bracket with gold leaf ornament, here the bracket is located the north of the speaker on the second floor - National Park Seminary, Ballroom, Linden Lane, Silver Spring, Montgomery County, MD

  2. Quantization with maximally degenerate Poisson brackets: the harmonic oscillator!

    NASA Astrophysics Data System (ADS)

    Nutku, Yavuz

    2003-07-01

    Nambu's construction of multi-linear brackets for super-integrable systems can be thought of as degenerate Poisson brackets with a maximal set of Casimirs in their kernel. By introducing privileged coordinates in phase space these degenerate Poisson brackets are brought to the form of Heisenberg's equations. We propose a definition for constructing quantum operators for classical functions, which enables us to turn the maximally degenerate Poisson brackets into operators. They pose a set of eigenvalue problems for a new state vector. The requirement of the single-valuedness of this eigenfunction leads to quantization. The example of the harmonic oscillator is used to illustrate this general procedure for quantizing a class of maximally super-integrable systems.

  3. Laser debonding of ceramic brackets: a comprehensive review.

    PubMed

    Azzeh, Ezz; Feldon, Paul J

    2003-01-01

    Since the invention of the ruby laser in the early 1960s, tremendous advances have been made in optic laser technology. Orthodontists have found various uses for lasers, including the debonding of ceramic brackets. Laser energy degrades the adhesive resin used to bond brackets. Consequently, lower forces can be used than when mechanical debonding is performed, reducing the risk of enamel damage. However, the heat produced by some lasers can damage the tooth pulp. Selecting the appropriate laser, resin, and bracket combination can minimize risks and make debonding more efficient. The purpose of this article is to give the clinician an up-to-date, comprehensive literature review about the clinical characteristics of debonding ceramic brackets with lasers.

  4. Notation for human immunogobulin subclasses.

    PubMed

    Kunkel, H G; Fahey, J L; Franklin, E C; Osserman, E F; Terry, W D

    1966-01-01

    After consultation between immunologists from a number of countries a nomenclature for human immunoglobulins was proposed in 1964 and was published in the Bulletin of the World Health Organization.(1) However, that proposed scheme of notation, which has already gained wide acceptance, left several specialized areas of nomenclature still to be resolved; one of these was the subclasses of immunoglobulins. Some of the research workers most closely concerned with the problem have now agreed upon a unified scheme for the notation of the human immunoglobulin subclasses, and, in particular, of the immunoglobulin G subclass, for which two different nomenclatorial schemes have been followed in recent years. Their proposals are given below.

  5. Static-dynamic friction transition of FRP esthetic orthodontic wires on various brackets by suspension-type friction test.

    PubMed

    Suwa, N; Watari, F; Yamagata, S; Iida, J; Kobayashi, M

    2003-11-15

    A new testing apparatus for the measurement of frictional properties was designed and the frictional coefficients were obtained and compared with each other in various combinations of brackets and orthodontic wires, including esthetic fiber-reinforced plastic (FRP) wire that was especially designed and manufactured. Three kinds of wires (stainless steel, nickel-titanium, and FRP) and four brackets (single-crystal alumina, polycrystalline alumina, polycarbonate, and stainless steel) were used. The testing was done under dry and wet conditions. The friction testing equipment was designed to attach the bracket to a C-shaped bar suspended with a variable mass, and sliding along a fixed wire. The transition between static and dynamic friction was measured as a breakaway force, with the use of a universal test machine. In addition to material properties, this testing fixture eliminates geometrical factors, such as the rotational moment at the edge of the bracket slot, deflection of the orthodontic wire, and tension of the ligature wire. Nearly ideal frictional properties between materials are obtained. The frictional properties of FRP wire were similar to those of metal wires on all brackets, except the polycrystalline alumina bracket. The frictional coefficient between the polycrystalline ceramic bracket and FRP wire was larger than that of other combinations. There was little difference in frictional coefficients between dry and wet conditions. Copyright 2003 Wiley Periodicals, Inc.

  6. Self-ligating versus conventional metallic brackets on Streptococcus mutans retention: A systematic review.

    PubMed

    Longoni, Juliano N; Lopes, Beatriz M; Freires, Irlan A; Dutra, Kamile L; Franco, Ademir; Paranhos, Luiz R

    2017-01-01

    The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans , 2 studies showed less accumulation in self-ligating than in conventional brackets. Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient - such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity.

  7. In vitro assessment of stainless steel orthodontic brackets coated with titanium oxide mixed Ag for anti-adherent and antibacterial properties against Streptococcus mutans and Porphyromonas gingivalis.

    PubMed

    Fatani, Eman Jameel; Almutairi, Hamed H; Alharbi, Ali O; Alnakhli, Yasser Obaidallah; Divakar, Darshan Devang; Muzaheed; Alkheraif, Abdulaziz Abdullah; Khan, Aftab Ahmed

    2017-11-01

    Orthodontic brackets made from stainless steel were introduced in dentistry, though they have less ability in reducing enamel demineralization and are not successful in preventing microbial as well as biofilm growth. In this study, we evaluated the significant role of different brackets in reducing enamel demineralization indirectly. Results from different tests indicate the significant reduction in adhesion, biofilm formation and slow growth of tested bacterial species on brackets coated with Ag + TiO2 and found to be statistically significant lower than control. There was no loss in cell viability in all brackets indicating that the cells are biocompatible with different bracket materials. Scanning electron microscopy showed less bacteria attached with the surface coated with Ag + TiO2 indicated that bacteria were losing adherent nature on coated surface. In conclusion, TiO2+Ag coating on stainless steel brackets possessed anti-adherent properties and also have demonstrable antibacterial properties therefore helps in preventing dental caries and plaque accumulation indirectly. The cell compatibility of TiO2+Ag coated brackets is superior to the uncoated samples therefore can be used in orthodontics as it not only provide suitable antimicrobial activity and resistance to biofilm formation but also sustained the cell viability of human gingival fibroblast (HGF) cell lines. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Color stability of ceramic brackets immersed in potentially staining solutions

    PubMed Central

    Guignone, Bruna Coser; Silva, Ludimila Karsbergen; Soares, Rodrigo Villamarim; Akaki, Emilio; Goiato, Marcelo Coelho; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2015-01-01

    OBJECTIVE: To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions. METHODS: Ninety brackets were divided into 5 groups (n = 18) according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva). The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA), Radiance (American Orthodontics, Sheboygan, WI, USA), Mystique (GAC International Inc., Bohemia, NY, USA) and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA). Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0), 24 hours (T1), 72 hours (T2), as well as 7 days (T3) and 14 days (T4) of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%. RESULTS: The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations. CONCLUSIONS: Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions. PMID:26352842

  9. Static and kinetic frictional forces of silica-insert ceramic brackets with coated archwires in artificial saliva.

    PubMed

    Shahabi, Mostafa; Salari, Soheil; Poosti, Maryam; Abtahi, Mostafa

    2017-01-01

    During sliding mechanics, the frictional force (FF) is an important counterforce to orthodontic tooth movement. The purpose of this in vitro study was to investigate the static and kinetic FFs of S silica-insert ceramic (SIC) brackets with Teflon-coated (TC) and conventional S stainless steel (SS) archwires. The target group of this study included 80 maxillary canine 0.022 inch slot SIC brackets. Forty SS brackets were used as the control. TC and conventional uncoated SS archwires of different dimensions (0.016, 0.018, 0.016 × 0.022, and 0.018 × 0.025 inch) were examined. All tests were carried out under artificial saliva injected condition. Scanning Electron Micrographs were prepared for two samples of coated and uncoated archwires. Analysis of variance and Tukey post hoc tests were used for statistical purposes (level of significance P < 0.05). SIC brackets showed significantly lower levels of FFs than SS brackets. TC archwires had greater frictional values than conventional uncoated ones. They also exhibited an unusual behavior of increasing kinetic FFs with time. Indentation and delamination of coating were obvious under scanning electron microscopy observations. From the standpoint of friction, SIC brackets may serve well, even better than SS brackets, in sliding mechanics. The coating layer of the archwires may delaminate and lost, causing an impediment to tooth movement.

  10. Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires.

    PubMed

    Polychronis, Georgios; Al Jabbari, Youssef S; Eliades, Theodore; Zinelis, Spiros

    2018-03-06

    The aim of this research was to assess galvanic behavior of lingual orthodontic brackets coupled with representative types of orthodontic wires. Three types of lingual brackets: Incognito (INC), In-Ovation L (IOV), and STb (STB) were combined with a stainless steel (SS) and a nickel-titanium (NiTi) orthodontic archwire. All materials were initially investigated by scanning electron microscopy / x-ray energy dispersive spectroscopy (SEM/EDX) while wires were also tested by x-ray diffraction spectroscopy (XRD). All bracket-wire combinations were immersed in acidic 0.1M NaCl 0.1M lactic acid and neutral NaF 0.3% (wt) electrolyte, and the potential differences were continuously recorded for 48 hours. The SEM/EDX analysis revealed that INC is a single-unit bracket made of a high gold (Au) alloy while IOV and STB are two-piece appliances in which the base and wing are made of SS alloys. The SS wire demonstrated austenite and martensite iron phase, while NiTi wire illustrated an intense austenite crystallographic structure with limited martensite. All bracket wire combinations showed potential differences below the threshold of galvanic corrosion (200 mV) except for INC and STB coupled with NiTi wire in NaF media. The electrochemical results indicate that all brackets tested demonstrated galvanic compatibility with SS wire, but fluoride treatment should be used cautiously with NiTi wires coupled with Au and SS brackets.

  11. Static and kinetic frictional forces of silica-insert ceramic brackets with coated archwires in artificial saliva

    PubMed Central

    Shahabi, Mostafa; Salari, Soheil; Poosti, Maryam; Abtahi, Mostafa

    2017-01-01

    Background: During sliding mechanics, the frictional force (FF) is an important counterforce to orthodontic tooth movement. The purpose of this in vitro study was to investigate the static and kinetic FFs of S silica-insert ceramic (SIC) brackets with Teflon-coated (TC) and conventional S stainless steel (SS) archwires. Materials and Methods: The target group of this study included 80 maxillary canine 0.022 inch slot SIC brackets. Forty SS brackets were used as the control. TC and conventional uncoated SS archwires of different dimensions (0.016, 0.018, 0.016 × 0.022, and 0.018 × 0.025 inch) were examined. All tests were carried out under artificial saliva injected condition. Scanning Electron Micrographs were prepared for two samples of coated and uncoated archwires. Analysis of variance and Tukey post hoc tests were used for statistical purposes (level of significance P < 0.05). Results: SIC brackets showed significantly lower levels of FFs than SS brackets. TC archwires had greater frictional values than conventional uncoated ones. They also exhibited an unusual behavior of increasing kinetic FFs with time. Indentation and delamination of coating were obvious under scanning electron microscopy observations. Conclusion: From the standpoint of friction, SIC brackets may serve well, even better than SS brackets, in sliding mechanics. The coating layer of the archwires may delaminate and lost, causing an impediment to tooth movement. PMID:29238380

  12. Color stability of ceramic brackets immersed in potentially staining solutions.

    PubMed

    Guignone, Bruna Coser; Silva, Ludimila Karsbergen; Soares, Rodrigo Villamarim; Akaki, Emilio; Goiato, Marcelo Coelho; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2015-01-01

    To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions. Ninety brackets were divided into 5 groups (n = 18) according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva). The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA), Radiance (American Orthodontics, Sheboygan, WI, USA), Mystique (GAC International Inc., Bohemia, NY, USA) and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA). Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0), 24 hours (T1), 72 hours (T2), as well as 7 days (T3) and 14 days (T4) of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%. The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations. Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  13. Laser radiation bracket debonding

    NASA Astrophysics Data System (ADS)

    Dostálová, Tat'jana; Jelínková, Helena; Šulc, Jan; Koranda, Petr; Nemec, Michal; Racek, Jaroslav; Miyagi, Mitsunobu

    2008-02-01

    Ceramic brackets are an aesthetic substitute for conventional stainless steel brackets in orthodontic patients. However, ceramic brackets are more brittle and have higher bond strengths, which can lead to bracket breakage and enamel damage during classical type of debonding. This study examined the possibility of laser radiation ceramic brackets removing as well as the possible damage of a surface structure of hard dental tissue after this procedure. Two types of lasers were used for the experiments - a laser diode LIMO HLU20F400 generating a wavelength of 808 nm with the maximum output power 20W at the end of the fiber (core diameter 400 μm, numerical aperture 0.22). As a second source, a diode-pumped Tm:YAP laser system generating a wavelength of 1.9 μm, with up to 3.8 W maximum output power was chosen. For the investigation, extracted incisors with ceramic brackets were used. In both cases, laser radiation was applied for 0.5 minute at a maximum power of 1 W. Temperature changes of the irradiated tissue was registered by camera Electrophysics PV320. After the interaction experiment, the photo-documentation was prepared by the stereomicroscope Nikon SMZ 2T, Japan. The surface tissue analysis was processed in "low vacuum" (30 Pa) regime without desiccation. This technique was used to record back-scattered electron images. Selecting the appropriate laser, resin, and bracket combination can minimize risks of enamel degradation and make debonding more safe.

  14. Shear bond strength and enamel fracture behavior of ceramic brackets Fascination® and Fascination®2.

    PubMed

    Gittner, Robert; Müller-Hartwich, Ralf; Engel, Sylvia; Jost-Brinkmann, Paul-Georg

    2012-01-01

    The purpose of this study was to compare the shear bond strength and incidence of enamel fractures of the ceramic brackets Fascination® and Fascination®2. A total of 360 teeth (180 first upper bicuspids and 180 lower incisors) were stored in 96% ethanol, while 360 other teeth (180 first upper bicuspids and 180 lower incisors) were stored in 0.1% thymol. All 720 teeth were bonded one-half each with Fascination® and Fascination®2 brackets using three different adhesives and three different light curing units. The teeth were debonded with a debonding-device according to DIN EN ISO 10477 using a universal testing machine with a crosshead speed of 1 mm per minute. The enamel surface was then examined stereomicroscopically (10x and 40x magnification). The non-parametric Mann-Whitney U test was used, since the data were not normally distributed. The Fascination®2 brackets provided significantly lower shear bond strength than Fascination® brackets (p = 0.003). Fascination® brackets demonstrated significantly fewer, smaller enamel fractures than Fascination®2 brackets (p = 0.012). The lower shear bond strength of the Fascination®2 brackets is clinically acceptable, but our study's experimental design did not enable us to prove whether this is clinically associated with a lower risk of enamel fracture.

  15. Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets – An Invitro Study

    PubMed Central

    Gill, Vikas; Reddy, Y. N. N.; Sanadhya, Sudhanshu; Aapaliya, Pankaj; Sharma, Nidhi

    2014-01-01

    Background: Debonding procedure is time consuming and damaging to the enamel if performed with improper technique. Various debonding methods include: the conventional methods that use pliers or wrenches, an ultrasonic method, electrothermal devices, air pressure impulse devices, diamond burs to grind the brackets off the tooth surface and lasers. Among all these methods, using debonding pliers is most convenient and effective method but has been reported to cause damage to the teeth. Recently, a New Debonding Instrument designed specifically for ceramic and composite brackets has been introduced. As this is a new instrument, little information is available on efficacy of this instrument. The purpose of this study was to evaluate the debonding characteristics of both “the conventional debonding Pliers” and “the New debonding instrument” when removing ceramic, composite and metallic brackets. Materials and Methods: One Hundred Thirty eight extracted maxillary premolar teeth were collected and divided into two Groups: Group A and Group B (n = 69) respectively. They were further divided into 3 subGroups (n = 23) each according to the types of brackets to be bonded. In subGroups A1 and B1{stainless steel};A2 and B2{ceramic};A3 and B3{composite}adhesive precoated maxillary premolar brackets were used. Among them {ceramic and composite} adhesive pre-coated maxillary premolar brackets were bonded. All the teeth were etched using 37% phosphoric acid for 15 seconds and the brackets were bonded using Transbond XT primer. Brackets were debonded using Conventional Debonding Plier and New Debonding Instrument (Group B). After debonding, the enamel surface of each tooth was examined under stereo microscope (10X magnifications). Amodifiedadhesive remnant index (ARI) was used to quantify the amount of remaining adhesive on each tooth. Results: The observations demonstrate that the results of New Debonding Instrument for debonding of metal, ceramic and composite brackets were statistically significantly different (p = 0.04) and superior from the results of conventional debonding Pliers. Conclusion: The debonding efficiency of New Debonding Instrument is better than the debonding efficiency of Conventional Debonding Pliers for use of metal, ceramic and composite brackets respectively. PMID:25177639

  16. Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets - An Invitro Study.

    PubMed

    Choudhary, Garima; Gill, Vikas; Reddy, Y N N; Sanadhya, Sudhanshu; Aapaliya, Pankaj; Sharma, Nidhi

    2014-07-01

    Debonding procedure is time consuming and damaging to the enamel if performed with improper technique. Various debonding methods include: the conventional methods that use pliers or wrenches, an ultrasonic method, electrothermal devices, air pressure impulse devices, diamond burs to grind the brackets off the tooth surface and lasers. Among all these methods, using debonding pliers is most convenient and effective method but has been reported to cause damage to the teeth. Recently, a New Debonding Instrument designed specifically for ceramic and composite brackets has been introduced. As this is a new instrument, little information is available on efficacy of this instrument. The purpose of this study was to evaluate the debonding characteristics of both "the conventional debonding Pliers" and "the New debonding instrument" when removing ceramic, composite and metallic brackets. One Hundred Thirty eight extracted maxillary premolar teeth were collected and divided into two Groups: Group A and Group B (n = 69) respectively. They were further divided into 3 subGroups (n = 23) each according to the types of brackets to be bonded. In subGroups A1 and B1{stainless steel};A2 and B2{ceramic};A3 and B3{composite}adhesive precoated maxillary premolar brackets were used. Among them {ceramic and composite} adhesive pre-coated maxillary premolar brackets were bonded. All the teeth were etched using 37% phosphoric acid for 15 seconds and the brackets were bonded using Transbond XT primer. Brackets were debonded using Conventional Debonding Plier and New Debonding Instrument (Group B). After debonding, the enamel surface of each tooth was examined under stereo microscope (10X magnifications). Amodifiedadhesive remnant index (ARI) was used to quantify the amount of remaining adhesive on each tooth. The observations demonstrate that the results of New Debonding Instrument for debonding of metal, ceramic and composite brackets were statistically significantly different (p = 0.04) and superior from the results of conventional debonding Pliers. The debonding efficiency of New Debonding Instrument is better than the debonding efficiency of Conventional Debonding Pliers for use of metal, ceramic and composite brackets respectively.

  17. Using music[al] knowledge to represent expressions of emotions.

    PubMed

    Alexander, Stewart C; Garner, David Kirkland; Somoroff, Matthew; Gramling, David J; Norton, Sally A; Gramling, Robert

    2015-11-01

    Being able to identify expressions of emotion is crucial to effective clinical communication research. However, traditional linguistic coding systems often cannot represent emotions that are expressed nonlexically or phonologically (i.e., not through words themselves but through vocal pitch, speed/rhythm/tempo, and volume). Using audio recording of a palliative care consultation in the natural hospital setting, two experienced music scholars employed Western musical notation, as well as the graphic realization of a digital audio program (Piano roll visualization), to visually represent the sonic features of conversation where a patient has an emotional "choke" moment. Western musical notation showed the ways that changes in pitch and rate correspond to the patient's emotion: rising sharply in intensity before slowly fading away. Piano roll visualization is a helpful supplement. Using musical notation to illustrate palliative care conversations in the hospital setting can render visible for analysis several aspects of emotional expression that researchers otherwise experience as intuitive or subjective. Various forms and formats of musical notation techniques and sonic visualization technologies should be considered as fruitful and complementary alternatives to traditional coding tools in clinical communications research. Musical notation offers opportunity for both researchers and learners to "see" how communication evolves in clinical encounters, particularly where the lexical and phonological features of interpersonal communication are concordant and discordant with one another. Copyright © 2015. Published by Elsevier Ireland Ltd.

  18. Effects of enamel sealing on shear bond strength and the adhesive remnant index : Study of three fluoride-releasing adhesives in combination with metal and ceramic brackets.

    PubMed

    Hofmann, Elisabeth; Elsner, Laura; Hirschfelder, Ursula; Ebert, Thomas; Hanke, Sebastian

    2017-01-01

    Selected combinations of materials were used to create tooth-adhesive-bracket complexes to evaluate shear bond strength (SBS) and the adhesive remnant index (ARI) with regard to enamel sealing. Four adhesive systems also appropriate for use as enamel sealants were combined with four bracket types, resulting in 16 adhesive-bracket combinations, each of which was tested on 15 permanent bovine incisors. Sealant-adhesives included two recently introduced fluoride-releasing systems (Riva bond LC ® and go! ® ), one established primer (Opal ® Seal™), and one commonly used adhesive as control (Transbond™ XT). Brackets included two metal (discovery ® by Dentaurum and Sprint ® ) and two ceramic (discovery ® pearl and GLAM ® ) systems. After embedding the bovine teeth, bonding the brackets to their surface, and storing the resultant samples as per DIN 13990-2 with modifications, an SBS test was performed by applying the shear force directly at the bracket base in an incisocervical direction. Then the ARI scores were determined. Discovery ®  + Transbond™ XT yielded the highest (47.2 MPa) and GLAM ®  + go! ® the lowest (17.0 MPa) mean SBS values. Significant differences (p < 0.0001) were found between metal and ceramic brackets of the same manufacturers (Dentaurum and Forestadent). Our ratings of the failure modes upon debonding predominantly yielded ARI 0 or 1. The high SBS values and low ARI scores observed with discovery ®  + Transbond XT™ were reflected in a high rate of enamel fracture, which occurred on 11 of the 15 tooth specimens in this group. All sealant-bracket combinations were found to yield levels of SBS adequate for clinical application. SBS values and ARI scores varied significantly depending on which sealant-brackets were used.

  19. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study

    PubMed Central

    Vinay, K; Venkatesh, M J; Nayak, Rabindra S; Pasha, Azam; Rajesh, M; Kumar, Pradeep

    2014-01-01

    Background: Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. Materials & Methods: In the study 48 combinations of brackets, archwires and different ligation techniques were tested in order to provide best combination that offers less friction during sliding mechanics. Instron- 4467 machine was used to evaluate static and kinetic friction force values and the results were subjected to Statistical Analysis and Anova test. Results: The results of the study showed that 0.022" metal brackets, Stainless steel wires and Slick modules provided the optimum frictional resistance to sliding mechanics. It is observed that frictional forces of 0.019" x 0.025" were higher when compared with 0.016" x 0.022" Stainless steel archwire due to the increase in dimension. Self-ligating brackets offered least friction followed by mini twin, variable force, regular stainless steel, ceramic with metal insert bracket and ceramic brackets. The stainless steel ligature offered less resistance than slick and grey modules, and TMA wires recorded maximum friction. Conclusion: The stainless steel archwire of 0.019" x 0.025" dimension are preferred during sliding mechanics, these archwires with variable force brackets ligated with Slick Modules offer decreased friction and is cost effective combination which can be utilized during sliding mechanics. How to cite the article: Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study. J Int Oral Health 2014;6(2):76-83. PMID:24876706

  20. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study.

    PubMed

    Vinay, K; Venkatesh, M J; Nayak, Rabindra S; Pasha, Azam; Rajesh, M; Kumar, Pradeep

    2014-04-01

    Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. In the study 48 combinations of brackets, archwires and different ligation techniques were tested in order to provide best combination that offers less friction during sliding mechanics. Instron- 4467 machine was used to evaluate static and kinetic friction force values and the results were subjected to Statistical Analysis and Anova test. The results of the study showed that 0.022" metal brackets, Stainless steel wires and Slick modules provided the optimum frictional resistance to sliding mechanics. It is observed that frictional forces of 0.019" x 0.025" were higher when compared with 0.016" x 0.022" Stainless steel archwire due to the increase in dimension. Self-ligating brackets offered least friction followed by mini twin, variable force, regular stainless steel, ceramic with metal insert bracket and ceramic brackets. The stainless steel ligature offered less resistance than slick and grey modules, and TMA wires recorded maximum friction. The stainless steel archwire of 0.019" x 0.025" dimension are preferred during sliding mechanics, these archwires with variable force brackets ligated with Slick Modules offer decreased friction and is cost effective combination which can be utilized during sliding mechanics. How to cite the article: Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study. J Int Oral Health 2014;6(2):76-83.

  1. The influence of different types of brackets and efficacy of two chlorhexidine mouthwashes on oral hygiene and the incidence of white spot lesions in adolescents during the orthodontic therapy.

    PubMed

    Jurišić, Sanja; Kozomara, Davorin; Jurić, Hrvoje; Verzak, Željko; Jurišić, Gordan

    2016-12-01

    To detect the effect of two different types of brackets (ceramic and stainless steel) and investigate the effectiveness of two chlorhexidine mouthwashes 0.2% (CHX) on oral hygiene status and incidence of white spot lesions (WSLs) in adolescents wearing fixed orthodontic appliance. One hundred and twenty subjects (aged 11 to 18 years, mean age 14.5 years) were divided into six equal groups according to brackets type and to different mouthwashes: Group 1: metal brackets and conventional CHX, Group 2: metal brackets and CHX with anti-discoloration system (CHX-ADS), Group 3: ceramic brackets and conventional CHX, Group 4: ceramic brackets and CHX-ADS, Group 5: metal brackets and water correction flavors mouthwash (placebo), Group 6: ceramic brackets and placebo. Four weeks after the placement of fixed orthodontic appliance the subjects were provided with three different mouthwashes for use during the next two weeks. Assessment was carried out according to oral hygiene index-simplified (OHI-S) and WSL index performed: prior to placement of the appliance (baseline), four weeks, six weeks, eighteen weeks, and thirty weeks after the placement. The data were then subjected to statistical analysis. Group 4 showed reduction in the OHI-S scores when compared to the Group 5 (in the 6 th week), and Group 6 (in the 6 th and 18 th week), which was statistically significant, P<0.05. Group 4 showed decrease in the WSLs scores when compared to the Group 1 (in the 4 th , 6 th , 18 th and 30 th week), Group 5 (in the 18 th and 30 th week) and Group 6 (in the 6 th , 18 th and 30 th week), which was statistically significant, P<0.05. The ceramic brackets and the usage of CHX-ADS resulted in better oral hygiene status and lower incidence of WSLs.

  2. An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Self-ligating Stainless Steel Brackets with different Dimensions of Archwires in Various Bracket-archwire Combination.

    PubMed

    Sridharan, K; Sandbhor, Shailesh; Rajasekaran, U B; Sam, George; Ramees, M Mohamed; Abraham, Esther A

    2017-08-01

    The purpose of this research is to compare the frictional attributes of stainless steel conventional brackets and self-ligating stainless steel brackets with different dimensions of archwires. The test was carried with two sets of maxillary brackets: (1) Conventional stainless steel (Victory Series), (2) stainless steel self-ligating (SmartClip) without first premolar brackets. Stainless steel, nickel-titanium (NiTi), and beta-Ti which are the types of orthodontic wire alloys were tested in this study. To monitor the frictional force, a universal testing machine (Instron 33R 4467) that comprises 10 kg tension load cell was assigned on a range of 1 kg and determined from 0 to 2 kg, which allows moving of an archwire along the brackets. One-way analysis of variance was used to test the difference between groups. To analyze the statistical difference between the two groups, Student's t-test was used. For Victory Series in static friction, p-value was 0.946 and for kinetic friction it was 0.944; at the same time for SmartClip, the p value for static and kinetic frictional resistance was 0.497 and 0.518 respectively. Hence, there was no statistically significant difference between the NiTi and stainless steel archwires. It is concluded that when compared with conventional brackets with stainless steel ligatures, self-ligating brackets can produce significantly less friction during sliding. Beta-Ti archwires expressed high amount of frictional resistance and the stainless steel archwires comprise low frictional resistance among all the archwire materials. In orthodontics, frictional resistance has always had a major role. Its ability to impair tooth movement leads to the need for higher forces to move the teeth and it extends the treatment time which results in loss of posterior anchorage. Friction in orthodontics is related with sliding mechanics when a wire is moving through one or a series of bracket slots.

  3. Evaluation of frictional resistance and surface characteristics after immersion of orthodontic brackets and wire in different chemical solutions: A comparative in vitrostudy.

    PubMed

    Nanjundan, Kavitha; Vimala, G

    2016-01-01

    To evaluate the changes of static and kinetic frictional forces between the brackets and wires following exposure to a soft drink, acidic food ingredient, and acidulated fluoride prophylactic agents. Two types of Roth prescription mandibular incisor brackets were used: 3M Unitek Victory stainless steel (SS) brackets (n = 40) and Transcend 6000 polycrystalline alumina (PCA) brackets (n = 40) as well as eighty 0.019 × 0.025" dimension ortho technology SS wires of 50 mm length each. Subsequently, brackets tied with SS wires divided into eight subgroups (n = 10) and were immersed in vinegar (pH = 3.5 ± 0.5), Pepsi ® (pH = 2.46), Colgate Phos-Flur mouth rinse (pH = 5.1), and artificial saliva (control group pH = 7) for 24 h. Changes in surface morphology under scanning electron microscope ×1000, surface roughness (Ra) with surface profilometer (single bracket and single wire from each subgroup), and frictional resistance using universal testing machine were evaluated. Highest mean (standard deviation) static frictional force of 2.65 (0.25) N was recorded in Pepsi ® followed by 2.57 (0.25) N, 2.40 (0.22) N, and 2.36 (0.17) N for Vinegar, Colgate Phos-Flur mouth rinse, and artificial saliva groups, respectively. In a similar order, lesser mean kinetic frictional forces obtained. PCA brackets revealed more surface deterioration and higher frictional force values than SS brackets. A significant positive correlation was observed between frictional forces and bracket slot roughness (r = 0.861 and 0.802, respectively, for static and kinetic frictional forces, p < 0.001 for both) and wire roughness (r = 0.243 and 0.242, respectively, for static and kinetic frictional forces, p < 0.05 for both). Findings may have long-term implications when acidic food substances are used during fixed orthodontic treatment. Further, in vivo studies are required to analyze the clinical effect of acidic mediums in the oral environment during orthodontic treatment.

  4. Torque efficiency of different archwires in 0.018- and 0.022-inch conventional brackets.

    PubMed

    Sifakakis, Iosif; Pandis, Nikolaos; Makou, Margarita; Eliades, Theodore; Katsaros, Christos; Bourauel, Christoph

    2014-01-01

    To compare the archwires inserted during the final stages of the orthodontic treatment with the generated moments at 0.018- and 0.022-inch brackets. The same bracket type, in terms of prescription, was evaluated in both slot dimensions. The brackets were bonded on two identical maxillary acrylic resin models, and each model was mounted on the orthodontic measurement and simulation system. Ten 0.017 × 0.025-inch TMA and ten 0.017 × 0.025-inch stainless steel archwires were evaluated in the 0.018-inch brackets. In the 0.022-inch brackets, ten 0.019 × 0.025-inch TMA and ten 0.019 × 0.025-inch stainless steel archwires were measured. A 15° buccal root torque (+15°) and then a 15° palatal root torque (-15°) were gradually applied to the right central incisor bracket, and the moments were recorded at these positions. A t-test was conducted to compare the generated moments between wires within the 0.018- and 0.022-inch bracket groups separately. The 0.017 × 0.025-inch archwire in the 0.018-inch brackets generated mean moments of 9.25 Nmm and 14.2 Nmm for the TMA and stainless steel archwires, respectively. The measured moments in the 0.022-inch brackets with the 0.019 × 0.025-inch TMA and stainless steel archwires were 6.6 Nmm and 9.3 Nmm, respectively. The 0.017 × 0.025-inch stainless steel and β-Ti archwires in the 0.018-inch slot generated higher moments than the 0.019 × 0.025-inch archwires because of lower torque play. This difference is exaggerated in steel archwires, in comparison with the β-Ti, because of differences in stiffness. The differences of maximum moments between the archwires of the same cross-section but different alloys were statistically significant at both slot dimensions.

  5. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state.

    PubMed

    Thorstenson, Glenys A; Kusy, Robert P

    2002-09-01

    When paired with a particular self-ligating bracket design, the material and the geometric characteristics of an archwire influence its resistance to sliding. Four designs of self-ligating brackets (1 with a slide, 3 with clips) were coupled with 5 types of archwires: 14-mil round austenitic nickel-titanium, 16 x 22-mil rectangular austenitic nickel-titanium, 19 x 25-mil rectangular austenitic nickel-titanium, 19 x 25-mil rectangular martensitic nickel-titanium, and 19 x 25-mil rectangular stainless steel. The resistance to sliding (RS) of each archwire-bracket couple was measured at second-order angles between -9 degrees and 9 degrees. Interbracket distances of 8 and 18 mm between the test bracket and the adjacent brackets mimicked closure of a premolar extraction. When clearance exists, the RS is negligible for self-ligating brackets with slides coupled to any size of wire as well as for those with clips when coupled to wires that do not contact the clip. Once the wire attains a certain size and contacts the clip, the RS depends on the archwire size, the bracket design, and the materials of the couple. When coupled with the 16 x 22-mil wire, the brackets with clips applied normal forces ranging from a low of 5.6 centi-Newtons (cN) (1 cN = 1 g) to a high of 230 cN. When clearance disappears, the RS increased proportionally with the second-order angle. The 19 x 25-mil stainless steel wires, which were the most stiff, increased at rates between 75 and 84 cN/degree; the 14-mil austenitic nickel-titanium wires, which were the least stiff, increased at rates from 2.6 to 5.4 cN/degree. The treatment objectives for a particular patient at a specific stage should determine the appropriate archwire-bracket combination.

  6. In vitro evaluation of microleakage under orthodontic brackets bonded with different adhesive systems.

    PubMed

    Atash, Ramin; Fneiche, Ali; Cetik, Sibel; Bahrami, Babak; Balon-Perin, Alain; Orellana, Maria; Glineur, Régine

    2017-01-01

    Adhesives systems have a drawback when utilized for bonding orthodontic brackets: they shrink during photopolymerization creating microleakage. The aim of this study was to assess the stability of different orthodontic adhesives around brackets and enamel. Sixty noncarious mandibular premolars extracted for orthodontic reasons were randomly divided into six groups of adhesives used for bonding brackets to dental enamel: NeoBond ® Light Cure Adhesive Kit, Transbond™ Plus Self-Etching, Victory V-Slot APC PLUS ® + Transbond™ MIP, Rely-A-Bond ® Kit, Light Cure Orthodontic Adhesive Kit (OptiBond ® ), and Transbond™ MIP. Following bonding, all teeth underwent 2500 cycles of thermal cycling in baths ranging from 5°C to 55°C before being immersed in 2% methylene blue for 24 h. All samples were examined under a binocular microscope to assess the degree of microleakage at the "bracket-adhesive" and "adhesive-enamel" interfaces in the gingival and occlusal regions of the bracket. A significant difference was found at the "occlusal bracket-adhesive" interface. The highest microleakage values were found in the occlusal region, although no significant. Microleakage was observed in all groups. Group 2 had the highest microleakage values whereas Group 6 had the lowest values.

  7. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    PubMed Central

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  8. Torsion bar stabilizer for a vehicle and method for mounting the stabilizer on the vehicle frame

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauber, C.J.

    This patent describes a method of mounting a stabilizing mechanism on a vehicle frame which is supported and biased on a suspension assembly at opposite sides of the frame. The frame includes overload stops riveted to opposite sides of the frame and the suspension assembly includes bracket assemblies which secure the vehicle's suspension springs to a wheel axle. The method comprises the following steps: removing an overload stop from each side of the vehicle frame; mounting a modified overload stop on each side of the frame which serves as both an overload stop and a support for the stabilizing mechanismmore » wherein the modified overload stop is mounted into the holes in the frame left from the removal of the overload stop; removing from each side of the vehicle the top bracket from the bracket assembly; inserting a modified top bracket into each bracket assembly wherein the top bracket assembly is modified to couple with the stabilizing mechanism; and mounting on the modified overload stops a torsion bar whose opposite ends are coupled to the modified top bracket by way of linkages.« less

  9. ACORNS: A Tool for the Visualisation and Modelling of Atypical Development

    ERIC Educational Resources Information Center

    Moore, D. G.; George, R.

    2011-01-01

    Across many academic disciplines visualisation and notation systems are used for modelling data and developing theory, but in child development visual models are not widely used; yet researchers and students of developmental difficulties may benefit from a visualisation and notation system which can clearly map developmental outcomes and…

  10. Cognitive Load Theory and Music Instruction

    ERIC Educational Resources Information Center

    Owens, Paul; Sweller, John

    2008-01-01

    In two experiments, the principles of cognitive load theory were applied to the design of alternatives to conventional music instruction hypothesised to facilitate learning. Experiment 1 demonstrated that spatial integration of visual text and musical notation, and dual-modal delivery of auditory text and musical notation, were superior to the…

  11. Orderedness and Stratificational "and" Nodes.

    ERIC Educational Resources Information Center

    Herrick, Earl M.

    It is possible to apply Lamb's stratificational theory and analysis to English graphonomy, but additional notation devices must be used to explain particular graphemes and their characteristics. The author presents cases where Lamb's notation is inadequate. In those cases, he devises new means for performing the analysis. The result of this…

  12. Evaluation of the U.S. Army’s Aids Education Program

    DTIC Science & Technology

    1992-03-25

    34 scaiac (contlinad) Initial Factor Notd : N. Preatation flatbed : Varimax Notation NedjiM Prai Factor Pattern Notated Factor Pattern Factor StrUCture...material, the graphics contained in this appendix may be reproduced in the form of slides, or enlarged, laminated and bound together for use as a flip

  13. 18 CFR 3a.31 - Classification markings and special notations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Classification markings and special notations. 3a.31 Section 3a.31 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES NATIONAL SECURITY INFORMATION Classification...

  14. 18 CFR 3a.31 - Classification markings and special notations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Classification markings and special notations. 3a.31 Section 3a.31 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES NATIONAL SECURITY INFORMATION Classification...

  15. 18 CFR 3a.31 - Classification markings and special notations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Classification markings and special notations. 3a.31 Section 3a.31 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES NATIONAL SECURITY INFORMATION Classification...

  16. Enhancement of the Acquisition Process for a Combat System-A Case Study to Model the Workflow Processes for an Air Defense System Acquisition

    DTIC Science & Technology

    2009-12-01

    Business Process Modeling BPMN Business Process Modeling Notation SoA Service-oriented Architecture UML Unified Modeling Language CSP...system developers. Supporting technologies include Business Process Modeling Notation ( BPMN ), Unified Modeling Language (UML), model-driven architecture

  17. Corrosion behavior of self-ligating and conventional metal brackets.

    PubMed

    Maia, Lúcio Henrique Esmeraldo Gurgel; Lopes Filho, Hibernon; Ruellas, Antônio Carlos de Oliveira; Araújo, Mônica Tirre de Souza; Vaitsman, Delmo Santiago

    2014-01-01

    To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek) and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek) metal brackets from three manufacturers (n = 150) were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1°C for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM) under 22X and 1,000X magnifications. Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05) than the GN group after 7 and 14 days, but less chromium (p < 0.05) after 14 days and less iron (p < 0.05) at the three experimental time intervals. The INs group released less iron (p < 0.05) than the GE group after 7 days and less nickel, chromium and iron (p < 0.05) after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05) than the VE group after 14 days, but released less nickel and chromium (p < 0.05) after 7 days and less chromium and iron (p < 0.05) after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted.

  18. Corrosion behavior of self-ligating and conventional metal brackets

    PubMed Central

    Maia, Lúcio Henrique Esmeraldo Gurgel; Lopes Filho, Hibernon; Ruellas, Antônio Carlos de Oliveira; Araújo, Mônica Tirre de Souza; Vaitsman, Delmo Santiago

    2014-01-01

    Objective To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Methods Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek) and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek) metal brackets from three manufacturers (n = 150) were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1ºC for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM) under 22X and 1,000X magnifications. Results Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05) than the GN group after 7 and 14 days, but less chromium (p < 0.05) after 14 days and less iron (p < 0.05) at the three experimental time intervals. The INs group released less iron (p < 0.05) than the GE group after 7 days and less nickel, chromium and iron (p < 0.05) after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05) than the VE group after 14 days, but released less nickel and chromium (p < 0.05) after 7 days and less chromium and iron (p < 0.05) after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. Conclusions The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted. PMID:24945521

  19. Comparison of some dietary habits on corrosion behavior of stainless steel brackets: an in vitro study.

    PubMed

    Shahabi, M; Jahanbin, A; Esmaily, H; Sharifi, H; Salari, S

    2011-01-01

    Resistance to corrosion is an advantageous property of orthodontic brackets; however, due to low levels of pH found in the mouth of a patient, localized corrosion may occur This can affect tooth movement by increasing friction between the arch wire and bracket slot and initiate enamel discoloration. Additionally, corrosion causes the release of elements that may lead to cytotoxic and biological side effects. The aim of this study was to compare the amount of corrosion caused by lemon juice, vinegar and Coca-Cola on orthodontic brackets in vitro and then to recommend the most suitable diet during orthodontic treatment. Sixty orthodontic brackets in three groups of twenty were immersed in a test solution (Fusamaya-Meyer artificial saliva plus lemon juice, vinegar or Coca-Cola) at a temperature of 37 degrees C +/- 1. Moreover, a negative control consisting of twenty brackets were put in pure artificial saliva. After 6 weeks the amount of corrosion was determined by measuring delta W of mean weights of brackets and the results were analyzed by general linear models (repeated measurement). Significant differences were seen during different weeks of the study (P < 0.001) and different solutions (P < 0.001). This study showed the amount of corrosion in orthodontic brackets was the most for cola followed by vinegar and then lemon juice. In addition, mean differences for cola versus lemon juice was -0.010 (sig. <0.001), vinegar versus lemon juice was -0.006 (sig. = 0.001) and cola versus vinegar was -0.004 (sig. = 0.013). Acidic effervescent soft drinks such as cola have to be eliminated or minimized in the nutritional diet of orthodontic patients because of their harmful effects on their brackets.

  20. Finite element analysis of slot wall deformation in stainless steel and titanium orthodontic brackets during simulated palatal root torque.

    PubMed

    Magesh, Varadaraju; Harikrishnan, Pandurangan; Kingsly Jeba Singh, Devadhas

    2018-04-01

    Torque applied on anterior teeth is vital for root positioning and stability. The aim of this study was to evaluate the detailed slot wall deformation in stainless steel (SS) and titanium (Ti) edgewise brackets during palatal root torque using finite element analysis. A finite element model was developed from a maxillary central incisor SS bracket (0.022 in). The generated torque values from an SS rectangular archwire (0.019 × 0.025 in) while twisting from 5° to 40° were obtained experimentally by a spine tester, and the calculated torque force was applied in the bracket slot. The deformations of the slot walls in both SS and Ti brackets were measured at various locations. There were gradual increases in the deformations of both bracket slot walls from the bottom to top locations. In the SS bracket slot for the 40° twist, the deformations were 9.28, 36.8, and 44.8 μm in the bottom, middle, and top slot wall locations, respectively. Similarly, in the Ti bracket slot for the 40° twist, the deformations were 39.2, 62.4, and 76.2 μm in the bottom, middle, and top slot wall locations, respectively. The elastic limits were reached at 28° for SS and at 37° for Ti. Both SS and Ti bracket slots underwent deformation during torque application. There are variations in the deformations at different locations in the slot walls and between the materials. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Clinical effects of pre-adjusted edgewise orthodontic brackets: a systematic review and meta-analysis.

    PubMed

    Papageorgiou, Spyridon N; Konstantinidis, Ioannis; Papadopoulou, Konstantina; Jäger, Andreas; Bourauel, Christoph

    2014-06-01

    Fixed-appliance treatment is a major part of orthodontic treatment, but clinical evidence remains scarce. Objective of this systematic review was to investigate how the therapeutic effects and side-effects of brackets used during the fixed-appliance orthodontic treatment are affected by their characteristics. SEARCH METHODS AND SELECTION CRITERIA: We searched MEDLINE and 18 other databases through April 2012 without restrictions for randomized controlled trials and quasi-randomized controlled trials investigating any bracket characteristic. After duplicate selection and extraction procedures, risk of bias was assessed also in duplicate according to Cochrane guidelines and quality of evidence according to the Grades of Recommendation. Assessment, Development and Evaluation approach. Random-effects meta-analyses, subgroup analyses, and sensitivity analyses were performed with the corresponding 95 per cent confidence intervals (CI) and 95 per cent prediction intervals (PI). We included 25 trials on 1321 patients, with most comparing self-ligated (SL) and conventional brackets. Based on the meta-analyses, the duration of orthodontic treatment was on average 2.01 months longer among patients with SL brackets (95 per cent CI: 0.45 to 3.57). The 95 per cent PIs for a future trial indicated that the difference could be considerable (-1.46 to 5.47 months). Treatment characteristics, outcomes, and side-effects were clinically similar between SL and conventional brackets. For most bracket characteristics, evidence is insufficient. Some meta-analyses included trials with high risk of bias, but sensitivity analyses indicated robustness. Based on existing evidence, no clinical recommendation can be made regarding the bracket material or different ligation modules. For SL brackets, no conclusive benefits could be proven, while their use was associated with longer treatment durations.

  2. Efficiency of compensatory orthodontic treatment of mild Class III malocclusion with two different bracket systems

    PubMed Central

    Aragón, Mônica L. C.; Bichara, Lívia M.; Flores-Mir, Carlos; Almeida, Guilherme; Normando, David

    2017-01-01

    ABSTRACT Objective: The purpose of this study was to assess the efficiency of compensatory orthodontic treatment of patients with mild Class III malocclusion with two preadjusted bracket systems. Method: Fifty-six matched patients consecutively treated for mild Class III malocclusion through compensatory dentoalveolar movements were retrospectively evaluated after analysis of orthodontic records. The sample was divided into two groups according to the brackets used: Group 1 = non-Class III compensated preadjusted brackets, Roth prescription (n = 28); Group 2 = compensated Class III preadjusted brackets, Capelozza III prescription (n = 28). Cephalometric analysis, number of appointments and missed appointments, months using Class III elastics, and bond/band failures were considered. Treatment time, Peer Assessment Rating (PAR) index at the beginning (PAR T1) and end of treatment (PAR T2) were used to calculate treatment efficiency. Comparison was performed using a MANOVA at p< 0.05. Results: Missed appointments, bond or band failures, number of months using the Class III intermaxillary elastics, and cephalometric measurements showed no statistically significant difference (p> 0.05) between groups. Patients treated with Roth brackets had a treatment time 7 months longer (p= 0.01). Significant improvement in the patient’s occlusion (PAR T2-T1) was observed for both groups without difference (p= 0.22). Conclusions: Orthodontic brackets designed for compensation of mild Class III malocclusions appear to be more efficient than non-compensated straight-wire prescription brackets. Treatment time for Class III patients treated with brackets designed for compensation was shorter than with Roth prescription and no difference in the quality of the occlusal outcome was observed. A prospective randomized study is suggested to provide a deeper look into this subject. PMID:29364379

  3. Esthetic perception of orthodontic appliances by Brazilian children and adolescents.

    PubMed

    Kuhlman, Deise Caldas; Lima, Tatiana Araújo de; Duplat, Candice Belchior; Capelli, Jonas

    2016-01-01

    The objective of this present study was to understand how children and adolescents perceive esthetic attractiveness of a variety of orthodontic appliances. It also analyzed preferences according to patients' age, sex and socioeconomic status. A photograph album consisting of eight photographs of different orthodontic appliances and clear tray aligners placed in a consenting adult with pleasing smile was used. A sample of children or adolescents aged between 8 and 17 years old (n = 276) was asked to rate each image for its attractiveness on a visual analog scale. Comparisons between the appliances attractiveness were performed by means of nonparametric statistics with Friedman's test followed by Dunn's multiple comparison post-hoc test. Correlation between appliances and individuals' socioeconomic status, age, sex, and esthetic perception was assessed by means of Spearman's correlation analysis. Attractiveness ratings of orthodontic appliances varied nonsignificantly for children in the following hierarchy: traditional metallic brackets with green elastomeric ligatures > traditional metallic brackets with gray elastomeric ligatures > sapphire esthetic brackets; and for adolescents, as follows: sapphire esthetic brackets > clear aligner without attachments > traditional metallic brackets with green elastomeric ligatures. The correlation between individuals' socioeconomic status and esthetic perception of a given appliance was negative and statistically significant for appliances such as the golden orthodontic brackets and traditional metallic brackets with green elastomeric ligatures. Metal appliances were considered very attractive, whereas aligners were classified as less attractive by children and adolescents. The correlation between esthetic perception and socioeconomic status revealed that individuals with a higher socioeconomic level judged esthetics as the most attractive attribute. For those with higher economic status, golden orthodontic brackets and traditional metallic brackets with green elastomeric ligatures were assessed as the worst esthetic option.

  4. Esthetic perception of orthodontic appliances by Brazilian children and adolescents

    PubMed Central

    Kuhlman, Deise Caldas; de Lima, Tatiana Araújo; Duplat, Candice Belchior; Capelli, Jonas

    2016-01-01

    ABSTRACT Objective: The objective of this present study was to understand how children and adolescents perceive esthetic attractiveness of a variety of orthodontic appliances. It also analyzed preferences according to patients' age, sex and socioeconomic status. Methods: A photograph album consisting of eight photographs of different orthodontic appliances and clear tray aligners placed in a consenting adult with pleasing smile was used. A sample of children or adolescents aged between 8 and 17 years old (n = 276) was asked to rate each image for its attractiveness on a visual analog scale. Comparisons between the appliances attractiveness were performed by means of nonparametric statistics with Friedman's test followed by Dunn's multiple comparison post-hoc test. Correlation between appliances and individuals' socioeconomic status, age, sex, and esthetic perception was assessed by means of Spearman's correlation analysis. Results: Attractiveness ratings of orthodontic appliances varied nonsignificantly for children in the following hierarchy: traditional metallic brackets with green elastomeric ligatures > traditional metallic brackets with gray elastomeric ligatures > sapphire esthetic brackets; and for adolescents, as follows: sapphire esthetic brackets > clear aligner without attachments > traditional metallic brackets with green elastomeric ligatures. The correlation between individuals' socioeconomic status and esthetic perception of a given appliance was negative and statistically significant for appliances such as the golden orthodontic brackets and traditional metallic brackets with green elastomeric ligatures. Conclusion: Metal appliances were considered very attractive, whereas aligners were classified as less attractive by children and adolescents. The correlation between esthetic perception and socioeconomic status revealed that individuals with a higher socioeconomic level judged esthetics as the most attractive attribute. For those with higher economic status, golden orthodontic brackets and traditional metallic brackets with green elastomeric ligatures were assessed as the worst esthetic option. PMID:27901230

  5. Retrieval analysis of different orthodontic brackets: the applicability of electron microprobe techniques for determining material heterogeneities and corrosive potential

    PubMed Central

    HOLST, Alexandra Ioana; HOLST, Stefan; HIRSCHFELDER, Ursula; von SECKENDORFF, Volker

    2012-01-01

    Objective The objective of this study was to investigate the applicability of micro-analytical methods with high spatial resolution to the characterization of the composition and corrosion behavior of two bracket systems. Material and methods The surfaces of six nickel-free brackets and six nickel-containing brackets were examined for signs of corrosion and qualitative surface analysis using an electron probe microanalyzer (EPMA), prior to bonding to patient's tooth surfaces and four months after clinical use. The surfaces were characterized qualitatively by secondary electron (SE) images and back scattered electron (BSE) images in both compositional and topographical mode. Qualitative and quantitative wavelength-dispersive analyses were performed for different elements, and by utilizing qualitative analysis the relative concentration of selected elements was mapped two-dimensionally. The absolute concentration of the elements was determined in specially prepared brackets by quantitative analysis using pure element standards for calibration and calculating correction-factors (ZAF). Results Clear differences were observed between the different bracket types. The nickel-containing stainless steel brackets consist of two separate pieces joined by a brazing alloy. Compositional analysis revealed two different alloy compositions, and reaction zones on both sides of the brazing alloy. The nickel-free bracket was a single piece with only slight variation in element concentration, but had a significantly rougher surface. After clinical use, no corrosive phenomena were detectable with the methods applied. Traces of intraoral wear at the contact areas between the bracket slot and the arch wire were verified. Conclusion Electron probe microanalysis is a valuable tool for the characterization of element distribution and quantitative analysis for corrosion studies. PMID:23032212

  6. A comparison between two lingual orthodontic brackets in terms of speech performance and patients' acceptance in correcting Class II, Division 1 malocclusion: a randomized controlled trial

    PubMed Central

    Haj-Younis, Samiha; Khattab, Tarek Z.; Hajeer, Mohammad Y.; Farah, Hassan

    2016-01-01

    ABSTRACT Objective: To compare speech performance and levels of oral impairment between two types of lingual brackets. Methods: A parallel-group randomized controlled trial was carried out on patients with Class II, Division 1 malocclusion treated at the University of Hama School of Dentistry in Hama, Syria. A total of 46 participants (mean age: 22.3 ± 2.3 years) with maxillary dentoalveolar protrusion were randomly distributed into two groups with 23 patients each (1:1 allocation ratio). Either STb (Ormco) or 7th Generation (Ormco) lingual brackets were applied. Fricative sound/s/ spectrograms were analyzed directly before intervention (T0), one week following premolar extraction prior to bracket placement (T1), within 24 hours of bracket bonding (T2), one month after (T3), and three months after (T4) bracket placement. Patients′ acceptance was assessed by means of standardized questionnaires. Results: After bracket placement, significant deterioration in articulation was recorded at all assessment times in the 7th Generation group, and up to T3 in the STb group. Significant intergroup differences were detected at T2 and T3. No statistically significant differences were found between the two groups in reported tongue irritation levels, whereas chewing difficulty was significantly higher in the 7th Generation group one month after bracket placement. Conclusions: 7th Generation brackets have more interaction with sound production than STb ones. Although patients in both groups complained of some degree of oral impairment, STb appliances appeared to be more comfortable than the 7th Generation ones, particularly within the first month of treatment. PMID:27653268

  7. A comparison between two lingual orthodontic brackets in terms of speech performance and patients' acceptance in correcting Class II, Division 1 malocclusion: a randomized controlled trial.

    PubMed

    Haj-Younis, Samiha; Khattab, Tarek Z; Hajeer, Mohammad Y; Farah, Hassan

    2016-01-01

    To compare speech performance and levels of oral impairment between two types of lingual brackets. A parallel-group randomized controlled trial was carried out on patients with Class II, Division 1 malocclusion treated at the University of Hama School of Dentistry in Hama, Syria. A total of 46 participants (mean age: 22.3 ± 2.3 years) with maxillary dentoalveolar protrusion were randomly distributed into two groups with 23 patients each (1:1 allocation ratio). Either STb (Ormco) or 7th Generation (Ormco) lingual brackets were applied. Fricative sound/s/ spectrograms were analyzed directly before intervention (T0), one week following premolar extraction prior to bracket placement (T1), within 24 hours of bracket bonding (T2), one month after (T3), and three months after (T4) bracket placement. Patients' acceptance was assessed by means of standardized questionnaires. After bracket placement, significant deterioration in articulation was recorded at all assessment times in the 7th Generation group, and up to T3 in the STb group. Significant intergroup differences were detected at T2 and T3. No statistically significant differences were found between the two groups in reported tongue irritation levels, whereas chewing difficulty was significantly higher in the 7th Generation group one month after bracket placement. 7th Generation brackets have more interaction with sound production than STb ones. Although patients in both groups complained of some degree of oral impairment, STb appliances appeared to be more comfortable than the 7th Generation ones, particularly within the first month of treatment.

  8. Nozzle dam having a unitary plug

    DOEpatents

    Veronesi, L.; Wepfer, R.M.

    1992-12-15

    Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator is disclosed. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket. 16 figs.

  9. Nozzle dam having a unitary plug

    DOEpatents

    Veronesi, Luciano; Wepfer, Robert M.

    1992-01-01

    Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket.

  10. In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets

    PubMed Central

    de Oliveira, Cibele Braga; Maia, Luiz Guilherme Martins; Santos-Pinto, Ary; Gandini Júnior, Luiz Gonzaga

    2014-01-01

    Objective The aim of this in vitro study was to analyze color stability of monocrystalline and polycrystalline ceramic brackets after immersion in dye solutions. Methods Seven ceramic brackets of four commercial brands were tested: Two monocrystalline and two polycrystalline. The brackets were immersed in four dye solutions (coffee, red wine, Coke and black tea) and in artificial saliva for the following times: 24 hours, 7, 14 and 21 days, respectively. Color changes were measured by a spectrophotometer. Data were assessed by Multivariate Profile Analysis, Analysis of Variance (ANOVA) and Multiple Comparison Tests of means. Results There was a perceptible change of color in all ceramic brackets immersed in coffee (ΔE* Allure = 7.61, Inspire Ice = 6.09, Radiance = 6.69, Transcend = 7.44), black tea (ΔE* Allure = 6.24, Inspire Ice = 5.21, Radiance = 6.51, Transcend = 6.14) and red wine (ΔE* Allure = 6.49, Inspire Ice = 4.76, Radiance = 5.19, Transcend = 5.64), but no change was noticed in Coke and artificial saliva (ΔE < 3.7). Conclusion Ceramic brackets undergo color change when exposed to solutions of coffee, black tea and red wine. However, the same crystalline structure, either monocrystalline or polycrystalline, do not follow the same or a similar pattern in color change, varying according to the bracket fabrication, which shows a lack of standardization in the manufacturing process. Coffee dye produced the most marked color changes after 21 days of immersion for most ceramic brackets evaluated. PMID:25279530

  11. Bracket slot and archwire dimensions: manufacturing precision and third order clearance.

    PubMed

    Joch, Astrid; Pichelmayer, Margit; Weiland, Frank

    2010-12-01

    To determine the accuracy of different manufacturer's dimensions of bracket slots and stainless steel archwires and compare these against the tolerance limits given by DIN 13971 and 13971-2. Further to calculate torque play and effective torque and to compare the results to nominal torque. A laboratory investigation. The Department of Orthodontics and Dentofacial Orthopedics at Medical University of Graz, Austria. Ten upper central incisor brackets (0·022 inch) from five different bracket systems were investigated. Bracket slot height was measured with leaf gauges. The height and width of 10 stainless steel archwires with dimensions either 0·019×0·022 or 0·020×0·025 inch were measured using a micrometer. All measured bracket slot heights were within the upper and lower tolerance limits given by DIN 13971-2. Archwires showed measurements outside the upper and lower tolerance limits given by DIN 13971. The smallest effective torque loss (4·5°) resulted from the combination of the 0·022-inch SPEED System bracket with the 0·020×0·025-inch SPEED Wire small upper. The highest torque loss (11·7°) was found with the 0·022-inch Damon 2 bracket and the 0·019×0·025-inch ECO Charge 1 archwire. The accuracy of the manufacturers dimension is not to be taken for granted. A perfect 'finishing' still requires correction bends put in by the orthodontist.

  12. Self-ligating versus conventional metallic brackets on Streptococcus mutans retention: A systematic review

    PubMed Central

    Longoni, Juliano N.; Lopes, Beatriz M.; Freires, Irlan A.; Dutra, Kamile L.; Franco, Ademir; Paranhos, Luiz R.

    2017-01-01

    Objective: The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. Material and methods: The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. Results: The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans, 2 studies showed less accumulation in self-ligating than in conventional brackets. Conclusion: Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient – such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity. PMID:29279684

  13. In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets.

    PubMed

    de Oliveira, Cibele Braga; Maia, Luiz Guilherme Martins; Santos-Pinto, Ary; Gandini Junior, Luiz Gonzaga

    2014-01-01

    The aim of this in vitro study was to analyze color stability of monocrystalline and polycrystalline ceramic brackets after immersion in dye solutions. Seven ceramic brackets of four commercial brands were tested: Two monocrystalline and two polycrystalline. The brackets were immersed in four dye solutions (coffee, red wine, Coke and black tea) and in artificial saliva for the following times: 24 hours, 7, 14 and 21 days, respectively. Color changes were measured by a spectrophotometer. Data were assessed by Multivariate Profile Analysis, Analysis of Variance (ANOVA) and Multiple Comparison Tests of means. There was a perceptible change of color in all ceramic brackets immersed in coffee (ΔE* Allure = 7.61, Inspire Ice = 6.09, Radiance = 6.69, Transcend = 7.44), black tea (ΔE* Allure = 6.24, Inspire Ice = 5.21, Radiance = 6.51, Transcend = 6.14) and red wine (ΔE* Allure = 6.49, Inspire Ice = 4.76, Radiance = 5.19, Transcend = 5.64), but no change was noticed in Coke and artificial saliva (ΔE < 3.7). Ceramic brackets undergo color change when exposed to solutions of coffee, black tea and red wine. However, the same crystalline structure, either monocrystalline or polycrystalline, do not follow the same or a similar pattern in color change, varying according to the bracket fabrication, which shows a lack of standardization in the manufacturing process. Coffee dye produced the most marked color changes after 21 days of immersion for most ceramic brackets evaluated.

  14. Knowledge representation for commonality

    NASA Technical Reports Server (NTRS)

    Yeager, Dorian P.

    1990-01-01

    Domain-specific knowledge necessary for commonality analysis falls into two general classes: commonality constraints and costing information. Notations for encoding such knowledge should be powerful and flexible and should appeal to the domain expert. The notations employed by the Commonality Analysis Problem Solver (CAPS) analysis tool are described. Examples are given to illustrate the main concepts.

  15. 78 FR 70047 - Request for the Technical Review of 25 Draft Skin Notation Assignments and Skin Notation Profiles

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-22

    ... used for substances identified as causing or contributing to allergic contact dermatitis (ACD) or other..., 4676 Columbia Parkway, Cincinnati, Ohio 45226. FOR FURTHER INFORMATION CONTACT: Naomi Hudson, NIOSH... professionals, employers, and other interested parties in protecting workers from chemical contact with the skin...

  16. Developing Systems of Notation as a Trace of Reasoning

    ERIC Educational Resources Information Center

    Tillema, Erik; Hackenberg, Amy

    2011-01-01

    In this paper, we engage in a thought experiment about how students might notate their reasoning for composing fractions multiplicatively (taking a fraction of a fraction and determining its size in relation to the whole). In the thought experiment we differentiate between two levels of a fraction composition scheme, which have been identified in…

  17. Effects of Music Notation Reinforcement on Aural Memory for Melodies

    ERIC Educational Resources Information Center

    Buonviri, Nathan

    2015-01-01

    The purpose of this study was to investigate effects of music notation reinforcement on aural memory for melodies. Participants were 41 undergraduate and graduate music majors in a within-subjects design. Experimental trials tested melodic memory through a sequence of target melodies, distraction melodies, and matched and unmatched answer choices.…

  18. Symbolic Notations and Students' Achievements in Algebra

    ERIC Educational Resources Information Center

    Peter, Ebiendele E.; Olaoye, Adetunji A.

    2013-01-01

    This study focuses on symbolic notations and its impact on students' achievement in Algebra. The main reason for this study rests on the observation from personal and professional experiences on students' increasing hatred for Algebra. One hundred and fifty (150) Senior Secondary School Students (SSS) from Ojo Local Education District, Ojo, Lagos,…

  19. Avoiding Communication in Dense Linear Algebra

    DTIC Science & Technology

    2013-08-16

    Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1.1 Asymptotic Notation . . . . . . . . . . . . . . . . . . . . . . . . . . . 6...and parallelizing Strassen’s matrix multiplication algorithm (Chapter 11). 6 Chapter 2 Preliminaries 2.1 Notation and Definitions In this section we...between computations and algo- rithms). The following definition is based on [56]: Definition 2.1. A classical algorithm in linear algebra is one that

  20. Articulated Multimedia Physics, Lesson 3, The Arithmetic of Scientific Notation.

    ERIC Educational Resources Information Center

    New York Inst. of Tech., Old Westbury.

    As the third lesson of the Articulated Multimedia Physics Course, instructional materials are presented in this study guide. An introductory description is given for scientific notation methods. The subject content is provided in scrambled form, and the use of matrix transparencies is required for students to control their learning process.…

  1. Ichi, Ni, 3, 4: Neural Representation of Kana, Kanji, and Arabic Numbers in Native Japanese Speakers

    ERIC Educational Resources Information Center

    Coderre, Emily L.; Filippi, Christopher G.; Newhouse, Paul A.; Dumas, Julie A.

    2009-01-01

    The Japanese language represents numbers in kana digit words (a syllabic notation), kanji numbers and Arabic numbers (logographic notations). Kanji and Arabic numbers have previously shown similar patterns of numerical processing, and because of their shared logographic properties may exhibit similar brain areas of numerical representation. Kana…

  2. New Bouncing Curved Arrow Technique for the Depiction of Organic Mechanisms

    ERIC Educational Resources Information Center

    Straumanis, Andrei R.; Ruder, Suzanne M.

    2009-01-01

    Many students fail to develop a conceptual understanding of organic chemistry. Evidence suggests this failure goes hand-in-hand with a failure to grasp the techniques, meaning, and usefulness of curved arrow notation. Use of curved arrow notation to illustrate electrophilic addition appears to be a critical juncture in student understanding.…

  3. An Introduction to Equilibrium Thermodynamics: A Rational Approach to Its Teaching. Part 1: Notation and Mathematics.

    ERIC Educational Resources Information Center

    Williams, Donald F.; Glasser, David

    1991-01-01

    Introduces and develops mathematical notation to assist undergraduate students in overcoming conceptual difficulties involving the underlying mathematics of state functions, which tend to be different from functions encountered by students in previous mathematical courses, because of the need to manipulate special types of partial derivatives and…

  4. Semantic Processing in the Production of Numerals across Notations

    ERIC Educational Resources Information Center

    Herrera, Amparo; Macizo, Pedro

    2012-01-01

    In the present work, we conducted a series of experiments to explore the processing stages required to name numerals presented in different notations. To this end, we used the semantic blocking paradigm previously used in psycholinguist studies. We found a facilitative effect of the semantic blocked context relative to the mixed context for Arabic…

  5. A Multimodal Neural Network Recruited by Expertise with Musical Notation

    ERIC Educational Resources Information Center

    Wong, Yetta Kwailing; Gauthier, Isabel

    2010-01-01

    Prior neuroimaging work on visual perceptual expertise has focused on changes in the visual system, ignoring possible effects of acquiring expert visual skills in nonvisual areas. We investigated expertise for reading musical notation, a skill likely to be associated with multimodal abilities. We compared brain activity in music-reading experts…

  6. Perceptions of Schooling, Pedagogy and Notation in the Lives of Visually-Impaired Musicians

    ERIC Educational Resources Information Center

    Baker, David; Green, Lucy

    2016-01-01

    This article discusses findings on schooling, pedagogy and notation in the life-experiences of amateur and professional visually-impaired musicians/music teachers, and the professional experiences of sighted music teachers who work with visually-impaired learners. The study formed part of a broader UK Arts and Humanities Research Council funded…

  7. Raising the Degree of Service-Orientation of a SOA-based Software System: A Case Study

    DTIC Science & Technology

    2009-12-01

    protocols, as well as executable processes that can be compiled into runtime scripts” [2] The Business Process Modeling Notation ( BPMN ) provides a...Notation ( BPMN ) 1.2. Jan. 2009. URL: http://www.omg.org/spec/ BPMN /1.2/ [25] .NET Framework Developer Center. .NET Remoting Overview. 2003. URL: http

  8. Examination of Modeling Languages to Allow Quantitative Analysis for Model-Based Systems Engineering

    DTIC Science & Technology

    2014-06-01

    x THIS PAGE INTENTIONALLY LEFT BLANK xi LIST OF ACRONYMS AND ABBREVIATIONS BOM Base Object Model BPMN Business Process Model & Notation DOD...SysML. There are many variants such as the Unified Profile for DODAF/MODAF (UPDM) and Business Process Model & Notation ( BPMN ) that have origins in

  9. 43 CFR 3815.8 - Notation required in application for patent; conditions required in patent.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... patent; conditions required in patent. 3815.8 Section 3815.8 Public Lands: Interior Regulations Relating... Notation required in application for patent; conditions required in patent. (a) Every application for patent for any minerals located subject to this Act must bear on its face, before being executed by the...

  10. 43 CFR 3815.8 - Notation required in application for patent; conditions required in patent.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... patent; conditions required in patent. 3815.8 Section 3815.8 Public Lands: Interior Regulations Relating... Notation required in application for patent; conditions required in patent. (a) Every application for patent for any minerals located subject to this Act must bear on its face, before being executed by the...

  11. 43 CFR 3815.8 - Notation required in application for patent; conditions required in patent.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... patent; conditions required in patent. 3815.8 Section 3815.8 Public Lands: Interior Regulations Relating... Notation required in application for patent; conditions required in patent. (a) Every application for patent for any minerals located subject to this Act must bear on its face, before being executed by the...

  12. 43 CFR 3815.8 - Notation required in application for patent; conditions required in patent.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... patent; conditions required in patent. 3815.8 Section 3815.8 Public Lands: Interior Regulations Relating... Notation required in application for patent; conditions required in patent. (a) Every application for patent for any minerals located subject to this Act must bear on its face, before being executed by the...

  13. Guitar Scales in Music Notation and Tablature Diagrams.

    ERIC Educational Resources Information Center

    Hammer, Petra

    This study guide was designed to help high school students learn the basic skills in classical guitar playing, technique, fingerboard knowledge, and musicianship. The introduction describes how to read the music notation that is presented in traditional music form and also in tablature diagrams showing finger positioning in the guitar neck.…

  14. 37 CFR 1.121 - Manner of making amendments in applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... strike-through except that double brackets placed before and after the deleted characters may be used to... shown by being placed within double brackets if strike-through cannot be easily perceived; (iii) The... deleted must not be presented with strike-through or placed within double brackets. The instruction to...

  15. Tool Releases Optical Elements From Spring Brackets

    NASA Technical Reports Server (NTRS)

    Gum, J. S.

    1984-01-01

    Threaded hooks retract bracket arms holding element. Tool uses three hooks with threaded shanks mounted in ring-shaped holder to pull on tabs to release optical element. One person can easily insert or remove optical element (such as prism or lens) from spring holder or bracket with minimal risk of damage.

  16. Bracket formulations and energy- and helicity-preserving numerical methods for incompressible two-phase flows

    NASA Astrophysics Data System (ADS)

    Suzuki, Yukihito

    2018-03-01

    A diffuse interface model for three-dimensional viscous incompressible two-phase flows is formulated within a bracket formalism using a skew-symmetric Poisson bracket together with a symmetric negative semi-definite dissipative bracket. The budgets of kinetic energy, helicity, and enstrophy derived from the bracket formulations are properly inherited by the finite difference equations obtained by invoking the discrete variational derivative method combined with the mimetic finite difference method. The Cahn-Hilliard and Allen-Cahn equations are employed as diffuse interface models, in which the equalities of densities and viscosities of two different phases are assumed. Numerical experiments on the motion of periodic arrays of tubes and those of droplets have been conducted to examine the properties and usefulness of the proposed method.

  17. Assessing the effects of hydrogen peroxide bleaching agent on the shear bond strength of orthodontic brackets.

    PubMed

    Andrighetto, Augusto Ricardo; de Leão Withers, Eduardo Henrique; Grando, Karlos Giovani; Ambrosio, Aldrieli Regina; Shimizu, Roberto Hideo; Melo, Ana Cláudia

    2016-01-01

    Tooth bleaching is, today, one of the most widespread cosmetic treatments in dental practice,  so it is important to determine whether it can interfere with orthodontic bonding or not. The aim of this study was to assess the in vitro effects of 35% hydrogen peroxide bleaching agent on the shear bond strength of orthodontic brackets. Forty-five upper bicuspids were divided into three groups (n = 15). In the control Group (C), the brackets were bonded without previous bleaching treatment. Group 1 (G1) was treated with 35% hydrogen peroxide bleaching agent 24 h before bracket bonding. Group 2 was also bleached, and the brackets were bonded after 30 days. The shear bond strength of the brackets was measured using an EMIC machine, and the results were analyzed by ANOVA. There were no statistically significant differences between the three groups (P > 0.05), with Group C showing a mean bond strength of 9.72 ± 2.63 MPa, G1 of 8.09 ± 2.63 MPa, and G2 of 11.15 ± 4.42 MPa. It was possible to conclude that 35% hydrogen peroxide bleaching agent does not affect the shear strength of orthodontic brackets bonded 24 h and 30 days after bleaching.

  18. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets.

    PubMed

    Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire

    2016-01-01

    The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey's tests. Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.

  19. The effect of ligation method on friction in sliding mechanics.

    PubMed

    Hain, Max; Dhopatkar, Ashish; Rock, Peter

    2003-04-01

    During orthodontic tooth movement with the preadjusted edgewise system, friction generated at the bracket/archwire interface tends to impede the desired movement. The method of ligation is an important contributor to this frictional force. This in vitro study investigated the effect of ligation method on friction and evaluated the efficacy of the new slick elastomeric modules from TP Orthodontics (La Porte, Ind), which are claimed to reduce friction at the module/wire interface. Slick modules were compared with regular nonslick modules, stainless steel ligatures, and the SPEED self-ligating bracket system (Strite Industries, Cambridge, Ontario, Canada). The effect of using slick modules with metal-reinforced ceramic (Clarity, 3M Unitek, Monrovia, Calif) and miniature brackets (Minitwin, 3M Unitek) was also examined. Results showed that, when considering tooth movement along a 0.019 x 0.025-in stainless steel archwire, saliva-lubricated slick modules can reduce static friction at the module/archwire interface by up to 60%, regardless of the bracket system. The SPEED brackets produced the lowest friction compared with the 3 other tested bracket systems when regular modules were used. The use of slick modules, however, with all of the ligated bracket types tested significantly reduced friction to below the values recorded in the SPEED groups. Loosely tied stainless steel ligatures were found to generate the least friction.

  20. Standardized languages and notations for graphical modelling of patient care processes: a systematic review.

    PubMed

    Mincarone, Pierpaolo; Leo, Carlo Giacomo; Trujillo-Martín, Maria Del Mar; Manson, Jan; Guarino, Roberto; Ponzini, Giuseppe; Sabina, Saverio

    2018-04-01

    The importance of working toward quality improvement in healthcare implies an increasing interest in analysing, understanding and optimizing process logic and sequences of activities embedded in healthcare processes. Their graphical representation promotes faster learning, higher retention and better compliance. The study identifies standardized graphical languages and notations applied to patient care processes and investigates their usefulness in the healthcare setting. Peer-reviewed literature up to 19 May 2016. Information complemented by a questionnaire sent to the authors of selected studies. Systematic review conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Five authors extracted results of selected studies. Ten articles met the inclusion criteria. One notation and language for healthcare process modelling were identified with an application to patient care processes: Business Process Model and Notation and Unified Modeling Language™. One of the authors of every selected study completed the questionnaire. Users' comprehensibility and facilitation of inter-professional analysis of processes have been recognized, in the filled in questionnaires, as major strengths for process modelling in healthcare. Both the notation and the language could increase the clarity of presentation thanks to their visual properties, the capacity of easily managing macro and micro scenarios, the possibility of clearly and precisely representing the process logic. Both could increase guidelines/pathways applicability by representing complex scenarios through charts and algorithms hence contributing to reduce unjustified practice variations which negatively impact on quality of care and patient safety.

  1. Calculating the dermal flux of chemicals with OELs based on their molecular structure: An attempt to assign the skin notation.

    PubMed

    Kupczewska-Dobecka, Małgorzata; Jakubowski, Marek; Czerczak, Sławomir

    2010-09-01

    Our objectives included calculating the permeability coefficient and dermal penetration rates (flux value) for 112 chemicals with occupational exposure limits (OELs) according to the LFER (linear free-energy relationship) model developed using published methods. We also attempted to assign skin notations based on each chemical's molecular structure. There are many studies available where formulae for coefficients of permeability from saturated aqueous solutions (K(p)) have been related to physicochemical characteristics of chemicals. The LFER model is based on the solvation equation, which contains five main descriptors predicted from chemical structure: solute excess molar refractivity, dipolarity/polarisability, summation hydrogen bond acidity and basicity, and the McGowan characteristic volume. Descriptor values, available for about 5000 compounds in the Pharma Algorithms Database were used to calculate permeability coefficients. Dermal penetration rate was estimated as a ratio of permeability coefficient and concentration of chemical in saturated aqueous solution. Finally, estimated dermal penetration rates were used to assign the skin notation to chemicals. Defined critical fluxes defined from the literature were recommended as reference values for skin notation. The application of Abraham descriptors predicted from chemical structure and LFER analysis in calculation of permeability coefficients and flux values for chemicals with OELs was successful. Comparison of calculated K(p) values with data obtained earlier from other models showed that LFER predictions were comparable to those obtained by some previously published models, but the differences were much more significant for others. It seems reasonable to conclude that skin should not be characterised as a simple lipophilic barrier alone. Both lipophilic and polar pathways of permeation exist across the stratum corneum. It is feasible to predict skin notation on the basis of the LFER and other published models; from among 112 chemicals 94 (84%) should have the skin notation in the OEL list based on the LFER calculations. The skin notation had been estimated by other published models for almost 94% of the chemicals. Twenty-nine (25.8%) chemicals were identified to have significant absorption and 65 (58%) the potential for dermal toxicity. We found major differences between alternative published analytical models and their ability to determine whether particular chemicals were potentially dermotoxic. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Effects of 445-nm Diode Laser-Assisted Debonding of Self-Ligating Ceramic Brackets on Shear Bond Strength.

    PubMed

    Stein, Steffen; Hellak, Andreas; Schauseil, Michael; Korbmacher-Steiner, Heike; Braun, Andreas

    2018-01-01

    The aim of this study was to measure the effect of irradiation with a novel 445-nm diode laser on the shear bond strength (SBS) of ceramic brackets before debonding. Thirty ceramic brackets (In-Ovation ® C, GAC) were bonded in standard manner to the planed and polished buccal enamel surfaces of 30 caries-free human third molars. Each tooth was randomly allocated to the laser or control group, with 15 samples per group. The brackets in the laser group were irradiated with the diode laser (SIROLaser Blue ® ; Sirona) on three sides of the bracket bases for 5 sec each (lateral-coronal-lateral, a total of 15 sec) immediately before debonding. SBS values were measured for the laser group and control group. To assess the adhesive remnant index (ARI) and the degree of enamel fractures, micrographs of the enamel surface were taken with 10-fold magnification after debonding. The SBS values were significantly lower statistically in the laser group in comparison with the control group (p < 0.05). The ARI scores were also significantly lower statistically in the laser group in comparison with the control group (p < 0.05). No bracket fractures or enamel fractures occurred in either group after debonding. Irradiation of ceramic brackets with the novel diode laser before debonding significantly reduces the SBS values. This is of clinical importance, as it means that the risk of damage to the teeth, bracket fractures, and the overall treatment time can be reduced.

  3. Easy Debonding of Ceramic Brackets Bonded with a Light-Cured Orthodontic Adhesive Containing Microcapsules with a CO2 Laser.

    PubMed

    Arima, Shiori; Namura, Yasuhiro; Tamura, Takahiko; Shimizu, Noriyoshi

    2018-03-01

    An easy debonding method for ceramic brackets using a light-cured Bis-GMA resin containing heat-expandable microcapsules and CO 2 laser was investigated. Ceramic brackets are used frequently in orthodontic treatment because of their desirable esthetic properties. However, the application of heavy force to ceramic brackets in debonding can fracture the tooth enamel and ceramic brackets, causing tooth pain. In total, 60 freshly extracted bovine permanent mandibular incisors were divided randomly into 10 groups of 6 specimens each, corresponding to the number of variables tested. Ceramic brackets were bonded to bovine permanent mandibular incisors using an orthodontic bonding agent containing heat-expandable microcapsules at different levels (0-30 wt%) and resin composite paste, and cured by a curing device. The bond strengths were measured before and after CO 2 laser irradiation, and the temperature increase in the pulp chamber in fresh human first premolars was also evaluated. With CO 2 laser irradiation for 5 sec to the bracket, the bond strength in the 25% microcapsule group decreased significantly, to ∼0.17-fold, compared with that of the no-laser group (p < 0.05). The maximum temperature increase in the pulp chamber was 5.3°C with laser irradiation, which was less than the level that induces pulp damage. From these results, it seems likely that the combined use of a light-cured orthodontic bonding agent containing microcapsules and a CO 2 laser is a simple debonding system for ceramic brackets, with less debonding time and enamel damage.

  4. A novel biomimetic orthodontic bonding agent helps prevent white spot lesions adjacent to brackets.

    PubMed

    Manfred, Lauren; Covell, David A; Crowe, Jennifer J; Tufekci, Eser; Mitchell, John C

    2013-01-01

    To compare changes in enamel microhardness adjacent to orthodontic brackets after using bonding agents containing various compositions of bioactive glass compared to a traditional resin adhesive following a simulated caries challenge. Extracted human third molars (n  =  10 per group) had orthodontic brackets bonded using one of four novel bioactive glass (BAG)-containing orthodontic bonding agents (BAG-Bonds) or commercially available Transbond-XT. The four new adhesives contained BAG in varying percentages incorporated into a traditional resin monomer mixture. Teeth were cycled through low-pH demineralizing and physiologic-pH remineralizing solutions once each day over 14 days. Microhardness was measured on longitudinal sections of the teeth 100, 200, and 300 µm from the bracket edge and beneath the brackets, at depths of 25 to 200 µm from the enamel surface. Normalized hardness values were compared using three-way analysis of variance. Significantly less reduction in enamel microhardness was found with the experimental adhesives at depths of 25 and 50 µm at all distances from the bracket edge. In all groups, there were no significant changes in enamel microhardness past 125-µm depth. Results varied with the different BAG-Bonds, with 81BAG-Bond showing the smallest decrease in enamel microhardness. The BAG-Bonds tested in this study showed a reduction in the amount of superficial enamel softening surrounding orthodontic brackets compared to a traditional bonding agent. The results indicate that clinically, BAG-Bonds may aid in maintaining enamel surface hardness, therefore helping prevent white spot lesions adjacent to orthodontic brackets.

  5. Light energy attenuation through orthodontic ceramic brackets at different irradiation times.

    PubMed

    Santini, Ario; Tiu, Szu Hui; McGuinness, Niall J P; Aldossary, Mohammed Saeed

    2016-09-01

    To evaluate the total light energy (TLE) transmission through three types of ceramic brackets with, bracket alone and with the addition of orthodontic adhesive, at different exposure durations, and to compare the microhardness of the cured adhesive. Three different makes of ceramic brackets, Pure Sapphire(M), Clarity™ ADVANCED(P) and Dual Ceramic(P) were used. Eighteen specimens of each make were prepared and allocated to three groups (n = 6). MARC(®)-resin calibrator was used to determine the light curing unit (LCU) tip irradiance (mW/cm(2)) and TLE (J/cm(2)) transmitted through the ceramic brackets, and through ceramic bracket plus Transbond™ XT Light Cure Adhesive, for 5, 10 and 20 s. Vickers-hardness values at the bottom of the cured adhesive were determined. Statistical analysis used one-way analysis of variance (ANOVA); P = 0.05. TLE transmission rose significantly among all samples with increasing exposure durations. TLE reaching the adhesive- enamel interface was less than 10 J/cm(2), and through monocrystalline and polycrystalline ceramic brackets was significantly different (P < 0.05). Pure Sapphire(M) showed the highest amount of TLE transmission and Vickers-hardness values for 5, 10 and 20 s. Following manufacturer's recommendations, insufficient TLE may be delivered to the adhesive: increasing the exposure durations may be required when adhesive is cured through ceramic brackets. Clinicians are advised to measure the tip irradiance of their LCUs and increase curing time beyond 5 s. Orthodontic clinicians should understand the type of light curing device and the orthodontic adhesive used in their practice.

  6. Shear bond resistance and enamel surface comparison after the bonding and debonding of ceramic and metallic brackets

    PubMed Central

    da Rocha, José Maurício; Gravina, Marco Abdo; Campos, Marcio José da Silva; Quintão, Cátia Cardoso Abdo; Elias, Carlos Nelson; Vitral, Robert Willer Farinazzo

    2014-01-01

    Objective To evaluate, in vitro, the shear bond strength presented by three brands of polycrystalline ceramic brackets and one brand of metallic bracket; verify the adhesive remnant index (ARI) after the tests, and analyze, through scanning electron microscopy (SEM) the enamel surface topography after debonding, detecting the release of mineral particles. Methods Sixty bovine lower incisors were used. Three ceramic brackets (Allure®, InVu®, and Clarity®) and one metallic bracket (Geneus®) were bonded with Transbond XT®. Kruskal-Wallis's test (significance level set at 5%) was applied to the results of share bond and ARI. Mann Whitney's test was performed to compare the pairs of brackets in relation to their ARI. Brown-Forsythe's test (significance level set at 5%) was applied to the results of enamel chemical composition. Comparisons between groups were made with Games-Howell's and the Post-hoc tests. Results No statistically significant difference was observed in relation to the shear bond strength loads. Clarity® brackets were the most affected in relation to the surface topography and to the release of mineral particles of enamel (calcium ions). Conclusion With regard to the ARI, there was a prevalence of score 4 (40.4%). As for enamel surface topography, the Geneus® bracket was the only one which did not show superficial tissue loss. The InVu® and Clarity® ones showed cohesive fractures in 33.3% and the Allure® in 50%, the latter being the one that presented most fractures during removal. PMID:24713563

  7. A multi-center randomized controlled trial to compare a self-ligating bracket with a conventional bracket in a UK population: Part 1: Treatment efficiency.

    PubMed

    O'Dywer, Lian; Littlewood, Simon J; Rahman, Shahla; Spencer, R James; Barber, Sophy K; Russell, Joanne S

    2016-01-01

    To use a two-arm parallel trial to compare treatment efficiency between a self-ligating and a conventional preadjusted edgewise appliance system. A prospective multi-center randomized controlled clinical trial was conducted in three hospital orthodontic departments. Subjects were randomly allocated to receive treatment with either a self-ligating (3M SmartClip) or conventional (3M Victory) preadjusted edgewise appliance bracket system using a computer-generated random sequence concealed in opaque envelopes, with stratification for operator and center. Two operators followed a standardized protocol regarding bracket bonding procedure and archwire sequence. Efficiency of each ligation system was assessed by comparing the duration of treatment (months), total number of appointments (scheduled and emergency visits), and number of bracket bond failures. One hundred thirty-eight subjects (mean age 14 years 11 months) were enrolled in the study, of which 135 subjects (97.8%) completed treatment. The mean treatment time and number of visits were 25.12 months and 19.97 visits in the SmartClip group and 25.80 months and 20.37 visits in the Victory group. The overall bond failure rate was 6.6% for the SmartClip and 7.2% for Victory, with a similar debond distribution between the two appliances. No significant differences were found between the bracket systems in any of the outcome measures. No serious harm was observed from either bracket system. There was no clinically significant difference in treatment efficiency between treatment with a self-ligating bracket system and a conventional ligation system.

  8. Comparison of friction force between corroded and noncorroded titanium nitride plating of metal brackets.

    PubMed

    Kao, Chia-Tze; Guo, Jia-Uei; Huang, Tsui-Hsien

    2011-05-01

    Titanium nitride (TiN) plating is a method to prevent metal corrosion and can increase the surface smoothness. The purpose of this study was to evaluate the friction forces between the orthodontic bracket, with or without TiN plating, and stainless steel wire after it was corroded in fluoride-containing solution. In total, 540 metal brackets were divided into a control group and a TiN-coated experimental group. The electrochemical corrosion was performed in artificial saliva with 1.23% acidulated phosphate fluoride (APF) as the electrolytes. Static and kinetic friction were measured by an EZ-test machine (Shimadazu, Tokyo, Japan) with a crosshead speed of 10 mm per minute over a 5-mm stretch of stainless steel archwire. The data were analyzed by using unpaired t test and analysis of variance (ANOVA). Both the control and TiN-coated groups' corrosion potential was higher with 1.23% APF solution than with artificial solution (P <0.05). In brackets without corrosion, both the static and kinetic friction force between the control and TiN-coated brackets groups showed a statistically significant difference (P <0.05). In brackets with corrosion, the control group showed no statistical difference on kinetic or static friction. The TiN-coated brackets showed a statistical difference (P <0.05) on kinetic and static friction in different solutions. TiN-coated metal brackets, with corrosion or without corrosion, cannot reduce the frictional force. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  9. 77 FR 41895 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-17

    ... bushing with a new bushing and deactivation pin, and installing a new or serviceable stowage bracket for... installation of a new bracket for stowing the deactivation pin. We are issuing this AD to prevent failure of... installing a new or serviceable stowage bracket for the deactivation pins on all airplanes powered by Pratt...

  10. 75 FR 52290 - Airworthiness Directives; Bombardier, Inc. Model DHC-8-300 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... support brackets that were manufactured using sheet metal have been found cracked on DHC-8 Series 300 aircraft. Investigation revealed that the failure of the support bracket was due to fatigue. Failure of the aileron terminal quadrant support bracket could result in an adverse reduction of aircraft roll control...

  11. 77 FR 10406 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    ... powered by Pratt & Whitney JT9D series engines require installation of a new bracket for stowing the... serviceable stowage bracket for the deactivation pins on all airplanes powered by Pratt & Whitney JT9D series... Pratt & Whitney JT9D series engines require installation of a new bracket for stowing the deactivation...

  12. Shear bond strength of metallic and ceramic brackets using color change adhesives.

    PubMed

    Stumpf, Aisha de Souza Gomes; Bergmann, Carlos; Prietsch, José Renato; Vicenzi, Juliane

    2013-01-01

    To determine the shear bond strength of orthodontic brackets using color change adhesives that are supposed to aid in removing excess of bonding material and compare them to a traditional adhesive. Ninety metallic and ninety ceramic brackets were bonded to bovine incisors using two color change adhesives and a regular one. A tensile stress was applied by a universal testing machine. The teeth were observed in a microscope after debonding in order to determine the Adhesive Remnant Index (ARI). The statistical analysis (ANOVA, Tukey, and Kruskall-Wallis tests) demonstrated that the mean bond strength presented no difference when metallic and ceramic brackets were compared, but the bond resistance values were significantly different for the three adhesives used. The most common ARI outcome was the entire adhesive remaining on the enamel. The bond strength was similar for metallic and ceramic brackets when the same adhesive system was used. ARI scores demonstrated that bonding with these adhesives is safe even when ceramic brackets were used. On the other hand, bond strength was too low for orthodontic purposes when Ortho Lite Cure was used.

  13. Apparatus for mounting photovoltaic power generating systems on buildings

    DOEpatents

    Russell, Miles C [Lincoln, MA

    2009-08-18

    Rectangular photovoltaic (PV) modules are mounted on a building roof by mounting stands that are distributed in rows and columns. Each stand comprises a base plate and first and second different height brackets attached to opposite ends of the base plate. Each first and second bracket comprises two module-support members. One end of each module is pivotally attached to and supported by a first module-support member of a first bracket and a second module-support member of another first bracket. At its other end each module rests on but is connected by flexible tethers to module-support members of two different second brackets. The tethers are sized to allow the modules to pivot up away from the module-support members on which they rest to a substantially horizontal position in response to wind uplift forces.

  14. Research and analysis on response characteristics of bracket-line coupling system under wind load

    NASA Astrophysics Data System (ADS)

    Jiayu, Zhao; Qing, Sun

    2018-01-01

    In this paper, a three-dimensional finite element model of bracket-line coupling system is established based on ANSYS software. Using the wind velocity time series which is generated by MATLAB as a power input, by comparing and analyzing the influence of different wind speeds and different wind attack angles, it is found that when 0 degree wind acts on the structure, wires have a certain damping effect in the bracket-line coupling system and at the same wind speed, the 90 degree direction is the most unfavorable wind direction for the whole structure according to the three kinds of angle wind calculated at present. In the bracket-line coupling system, the bracket structure is more sensitive to the increase of wind speed while the conductors are more sensitive to the change of wind attack angle.

  15. Engineering and experimental analyses of the tensile loads applied during strength testing of direct bonded orthodontic brackets.

    PubMed

    Katona, T R; Chen, J

    1994-08-01

    The stress levels within the cement layer (hence, the apparent strength) of a direct bonded orthodontic bracket depends, to a large extent, on the alignment of the tensile loads that are applied to the specimen. The purpose of this analysis was to determine how the construction of a ligature wire harness affects the alignment of the applied loads. Tensile tests conducted on a modified bracket/cement system showed large variations in the force-elongation curve profiles. An engineering model was developed to explain these deviations. The results indicate that it is virtually impossible to evenly apply tensile loads to the bracket. It was also proposed that long harnesses constructed with thin ligature wire, prestressing the harness, and lubrication may reduce some of the effects of unavoidable load-bracket misalignment.

  16. A Progression in First-Grade Children's Thinking about Variable and Variable Notation in Functional Relationships

    ERIC Educational Resources Information Center

    Blanton, Maria; Brizuela, Bárbara M.; Gardiner, Angela Murphy; Sawrey, Katie; Newman-Owens, Ashley

    2017-01-01

    Recent research suggests that children in elementary grades have some facility with variable and variable notation in ways that warrant closer attention. We report here on an empirically developed progression in first-grade children's thinking about these concepts in functional relationships. Using learning trajectories research as a framework for…

  17. Glossing for Improved Comprehension: Progress and Prospect.

    ERIC Educational Resources Information Center

    Otto, Wayne; Hayes, Bernie

    The terms gloss and glossing are being used to designate and describe the systematic use of marginal notes and other extra-text notations to direct readers' attention while they read. Gloss notations may serve as an aid to direct students to content areas of text and to levels of understanding that make optimal use of their current--and sometimes…

  18. The Effects of In-School Stave Notation Learning on Student's Symbolising Behaviour and Musical Perception

    ERIC Educational Resources Information Center

    Elkoshi, Rivka

    2007-01-01

    Facing the ambiguous status of in-school music literacy, this follow-up eight-year study aims to touch on the effects of traditional staff notation (SN) learning on student's intuitive symbolizing behavior and musical perception. Subjects were 47 second-graders attending a religious Jewish school in Israel. One "pre-literate" meeting, in…

  19. Effects of Heat and Moisture Transfer Properties of Fabric on Heat Strain in Chemical Protective Ensembles

    DTIC Science & Technology

    2017-06-01

    11 Table 1 Notation for fabric and ensemble resistances . .......................................... 13 Thermal manikin...Table 1 Notation for fabric and ensemble resistances .................................................. 13 Table 2 Weight reduction of CB garment...samples were tested on a Sweating Guarded Hot Plate (SGHP) to measure fabric thermal and evaporative resistance , respectively. The ensembles were tested

  20. Reading a Note, Reading a Mind: Children's Notating Skills and Understanding of Mind

    ERIC Educational Resources Information Center

    Leyva, Diana; Hopson, Sarah; Nichols, Ashley

    2012-01-01

    Are children's understanding of mental states (understanding of mind) related to their notating skills, that is, their ability to produce and read written marks to convey information about objects and number? Fifty-three preschoolers and kindergarteners were presented with a dictation task where they produced some written marks and were later…

  1. Diagrams and Math Notation in E-Learning: Growing Pains of a New Generation

    ERIC Educational Resources Information Center

    Smith, Glenn Gordon; Ferguson, David

    2004-01-01

    Current e-learning environments are ill-suited to college mathematics. Instructors/students struggle to post diagrams and math notation. A new generation of math-friendly e-learning tools, including WebEQ, bundled with Blackboard 6, and NetTutor's Whiteboard, address these problems. This paper compares these two systems using criteria for ideal…

  2. Widening Possibilities of Interpretation When Observing Learning and Teaching through the Use of a Dynamic Visual Notation

    ERIC Educational Resources Information Center

    Kell, Clare; Sweet, John

    2017-01-01

    This paper shows how peer observation of learning and teaching (POLT) discussions can be augmented through the use of a dynamic visual notation that makes visible for interpretation, elements of teacher-learner and learner-earner nonverbal interactions. Making visible the nonverbal, physical, spatial and kinesics (eye-based) elements of…

  3. The Use of Force Notation to Detect Students' Misconceptions: Mutual Interactions Case

    ERIC Educational Resources Information Center

    Serhane, Ahcene; Zeghdaoui, Abdelhamid; Debiache, Mehdi

    2017-01-01

    Using a conventional notation for representing forces on diagrams, students were presented with questions on the interaction between two objects. The results show that complete understanding of Newton's Third Law of Motion is quite rare, and that some problems relate to misunderstanding which force acts on each body. The use of the terms…

  4. Preserving Musicality through Pictures: A Linguistic Pathway to Conventional Notation

    ERIC Educational Resources Information Center

    Nordquist, Alice L.

    2016-01-01

    The natural musicality so often present in children's singing can begin to fade as the focus of a lesson shifts to the process of reading and writing conventional notation symbols. Approaching the study of music from a linguistic perspective preserves the pace and flow that is inherent in spoken language and song. SongWorks teaching practices…

  5. 19 CFR 141.90 - Notation of tariff classification and value on invoice.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Notation of tariff classification and value on... classification and value on invoice. (a) [Reserved] (b) Classification and rate of duty. The importer or customs... invoice value which have been made to arrive at the aggregate entered value. In addition, the entered unit...

  6. Children's Invented Notations and Verbal Responses to a Piano Work by Claude Debussy

    ERIC Educational Resources Information Center

    Elkoshi, Rivka

    2015-01-01

    This study considers the way children listen to classical music composed for them and the effect of age on their spontaneous invented notations and verbal responses. The musical selection is a piano piece for children by Claude Debussy:"'Jimbo's Lullaby" from "Children's Corner". Two hundred and nine children 4-9.5-years-old…

  7. Beacon Editor: Capturing Signal Transduction Pathways Using the Systems Biology Graphical Notation Activity Flow Language.

    PubMed

    Elmarakeby, Haitham; Arefiyan, Mostafa; Myers, Elijah; Li, Song; Grene, Ruth; Heath, Lenwood S

    2017-12-01

    The Beacon Editor is a cross-platform desktop application for the creation and modification of signal transduction pathways using the Systems Biology Graphical Notation Activity Flow (SBGN-AF) language. Prompted by biologists' requests for enhancements, the Beacon Editor includes numerous powerful features for the benefit of creation and presentation.

  8. Children's Use of Variables and Variable Notation to Represent Their Algebraic Ideas

    ERIC Educational Resources Information Center

    Brizuela, Bárbara M.; Blanton, Maria; Sawrey, Katharine; Newman-Owens, Ashley; Murphy Gardiner, Angela

    2015-01-01

    In this article, we analyze a first grade classroom episode and individual interviews with students who participated in that classroom event to provide evidence of the variety of understandings about variable and variable notation held by first grade children approximately six years of age. Our findings illustrate that given the opportunity,…

  9. Corrigendum to "On the relation between conservation and dual consistency for summation-by-parts schemes" [J. Comput. Phys. 344 (2017) 437-439

    NASA Astrophysics Data System (ADS)

    Nordström, Jan; Ghasemi, Fatemeh

    2018-05-01

    A few notational errors were recently discovered in the above publication. The notation used in the note is valid for fluxes of the form fL (u) =AL u ,fR (v) =AR v where AL =AR is m × m constant symmetric matrix.

  10. Physical and adhesive properties of dental enamel after radiotherapy and bonding of metal and ceramic brackets.

    PubMed

    Santin, Gabriela Cristina; Palma-Dibb, Regina Guenka; Romano, Fábio Lourenço; de Oliveira, Harley Francisco; Nelson Filho, Paulo; de Queiroz, Alexandra Mussolino

    2015-08-01

    The increasing success rates for cancer patients treated with radiotherapy and the frequent occurrence of tooth loss during treatment have led to an increased demand for orthodontic treatment after radiotherapy. The aim of this study was to evaluate tooth enamel of irradiated teeth after the bonding and debonding of metal and ceramic brackets. Ten permanent molars were cut into enamel fragments measuring 1 mm(2) and divided into an irradiated group (total dose of 60 Gy) and a nonirradiated group. The fragments were subjected to microshear testing to evaluate whether radiotherapy altered the strength of the enamel. Furthermore, 90 prepared premolars were divided into 6 groups and subgroups (n = 15): group 1, nonirradiated and nonaged; group 2, nonirradiated and aged (thermal cycled); group 3, irradiated and aged; each group was divided into 2 subgroups: metallic and ceramic brackets. After thermal cycling and radiotherapy, the brackets were bonded onto the specimens with Transbond XT (3M Unitek, Monrovia, Calif). After 24 hours, the specimens were subjected to the shear tests. Images of the enamel surfaces were classified using the adhesive remnant index. The composite resin-enamel interface was also evaluated. Enamel fragments subjected to radiation had lower strength than did the nonirradiated samples (P <0.05). The groups and subgroups submitted to radiation and bonded ceramic brackets had the lowest strength values. Groups 1 and 2 with metallic brackets had less adhesive on the surface, whereas groups 1 and 2 with ceramic brackets and group 3 with both metallic and ceramic brackets had more adhesive on the surfaces. On the images of the composite resin-enamel interface, resin tags were more extensive on irradiated tooth enamel. Radiation decreased tooth enamel strength, and the specimens treated with radiotherapy had higher frequencies of adhesive failure between the bracket and the composite resin as well as more extensive tags. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. Titanium orthodontic brackets: structure, composition, hardness and ionic release.

    PubMed

    Gioka, Christiana; Bourauel, Christoph; Zinelis, Spiros; Eliades, Theodore; Silikas, Nikolaos; Eliades, George

    2004-09-01

    The aim of the present study was to investigate the composition, morphology, bulk structure and ionic release of two brands of titanium orthodontic brackets: Orthos2 (Ormco, USA) and Rematitan (Dentaurum, Germany). Five specimens of each group were examined with computerized X-ray microtomography, to reveal the morphology and structure of brackets, whilst resin-embedded and metallographically polished specimens were subjected to SEM/EDS analysis and Vickers microhardness measurements. Brackets were also maintained in 0.9% saline for 2 months and the ionic release in the immersion medium was determined with Inductively Coupled Plasma Atomic Emission Spectroscopy. The results of the hardness and ionic release measurements were statistically analyzed with two-way ANOVA and Tukey's test (alpha = 0.05). Orthos2 brackets consisted of two parts, the base (commercially pure Ti grade II) and the wing (Ti-6Al-4V alloy), joined together by laser welding, producing large gaps along the base-wing interface. The base was of lower hardness (Hv = 145), than the wing (Hv = 392) and incorporated a standard foil base-mesh pad. Rematitan brackets consisted of commercially pure Ti grade IV, with a single-piece manufacturing pattern of virtually identical hardness (p > 0.05) at the base and wings, featuring a laser-etched base-mesh pad. The hardness of the Rematitan brackets was significantly lower than the hardness of the Orthos2 wings, but double the hardness of the Orthos2 base. Released Ti levels were below the threshold level (1 ng/ml) of analysis for both materials, whilst traces of Al (3 ppm) and V (2 ppm) were found in the immersion media for Ti-6Al-4V alloy. The structural and hardness differences found may influence the torque transfer characteristics from activated archwires to the brackets and the crevice corrosion potential at the base-wing interface (Orthos2). The detection of Al and V in the immersion medium (Orthos2) may imply a different biological response from the two types of Ti brackets.

  12. Intrapulpal Temperature Increase During Er:YAG Laser-Aided Debonding of Ceramic Brackets.

    PubMed

    Yilanci, Hilal; Yildirim, Zeynep Beyza; Ramoglu, Sabri Ilhan

    2017-04-01

    The purpose of this study was to evaluate the temperature changes in the pulp chamber while using a newly introduced application of Er:YAG laser to debond ceramic brackets in a study model with a pulpal circulation with and without thermocycled samples. An esthetic alternative to stainless steel brackets, ceramic brackets have been proposed. However, because of their low fracture resistance and high bond strengths, ceramic brackets can cause a problem when they are being removed using conventional techniques. Experimental Groups A and B were established for samples with or without thermocycling. The same 20 maxillary central incisor and 20 premolar teeth were used in both groups. Pulpal blood microcirculation was simulated using an apparatus described in a previous study. Monocrystalline brackets were bonded by using Transbond XT. In Group A, brackets were debonded using the Er:YAG laser (600 mJ, 2 Hz, long pulse, and no air or water spray) after being stored in distilled water for 24 h. In Group B, brackets were debonded using the same laser system as that used in Group A after being stored in distilled water for 24 h and then thermocycled for a total of 5000 cycles between 5°C and 55°C. The laser irradiation duration and intrapulpal temperature changes were measured. In Group B, the intrapulpal temperature increase of the central incisors was significantly higher than that of the premolar teeth. In the central incisor and premolar teeth groups, there were no statistically significant difference between Groups A and B (p > 0.05). A positive correlation was found between laser irradiation duration and temperature increase (p < 0.01). The use of Er:YAG laser is an effective method for debonding the monocrystalline ceramic brackets. This method can be used safely under the consideration of intrapulpal temperature changes.

  13. Fluoride releasing and enamel demineralization around orthodontic brackets by fluoride-releasing composite containing nanoparticles.

    PubMed

    Melo, Mary A S; Morais, Weslanny A; Passos, Vanara F; Lima, Juliana P M; Rodrigues, Lidiany K A

    2014-05-01

    Fluoride-containing materials have been suggested to control enamel demineralization around orthodontic brackets during the treatment with fixed appliances. The improvement of their properties has been made through innovations, such as the application of nanotechnology by incorporation of nanofillers. This in vitro study evaluated the capacity of fluoride releasing and enamel demineralization inhibition of fluoride-releasing nanofilled cement around orthodontic brackets using an artificial caries biofilm model. Forty bovine enamel discs were selected by evaluating surface microhardness and randomized into four groups (n = 10): non-fluoride-releasing microfilled composite, fluoride-releasing microfilled composite, resin-modified glass ionomer cement (RMGI), and fluoride-releasing nanofilled composite (FN). After brackets bonding in each disc, the specimens were subjected to a cariogenic challenge through a Streptococcus mutans biofilm model. After the experimental period, the biofilm formed around the brackets was collected for fluoride analysis and the mineral loss around the brackets was determined by integrated demineralization via cross-sectional microhardness measurement at 20 and 70 μm from the bracket margin. Additionally, samples of each group were subjected to energy-dispersive X-ray spectroscopy (EDX) analysis examined under a scanning electron microscopy (SEM). ANOVA followed by Tukey test were applied for fluoride concentration and mineral loss data, respectively. At both distances, only RMGI statistically differed from the other groups presenting the lowest demineralization, although there was a trend to a lower demineralization of enamel around brackets in FN group. Similar condition was found to fluoride concentration and EDX/SEM analysis. Under the cariogenic exposure condition of this study, the fluoride-releasing nanofilled material had similar performance to fluoride-releasing microfilled materials. The presence of nanofillers in the fluoride-releasing materials studied did not promote further benefits against caries lesion development around brackets and presented inferior demineralization inhibition than the resin-modified glass ionomer material.

  14. Strength Analysis and Process Simulation of Subway Contact Rail Support Bracket of Composite Materials

    NASA Astrophysics Data System (ADS)

    Fedulov, Boris N.; Safonov, Alexander A.; Sergeichev, Ivan V.; Ushakov, Andrey E.; Klenin, Yuri G.; Makarenko, Irina V.

    2016-10-01

    An application of composites for construction of subway brackets is a very effective approach to extend their lifetime. However, this approach involves the necessity to prevent process-induced distortions of the bracket due to thermal deformation and chemical shrinkage. At present study, a process simulation has been carried out to support the design of the production tooling. The simulation was based on the application of viscoelastic model for the resin. Simulation results were verified by comparison with results of manufacturing experiments. To optimize the bracket structure the strength analysis was carried out as well.

  15. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets

    PubMed Central

    Cardoso, Mauricio de Almeida; Saraiva, Patrícia Pinto; Maltagliati, Liliana Ávila; Rhoden, Fernando Kleinübing; Costa, Carla Cristina Alvarenga; Normando, David; Capelozza, Leopoldino

    2015-01-01

    OBJECTIVE: The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. METHODS: Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI), gingival bleeding index (GBI) and clinical attachment level (CAL) were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional), two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. RESULTS: No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL) in either one of the systems. CONCLUSION: No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored. PMID:25992985

  16. Elemental, microstructural, and mechanical characterization of high gold orthodontic brackets after intraoral aging.

    PubMed

    Hersche, Sepp; Sifakakis, Iosif; Zinelis, Spiros; Eliades, Theodore

    2017-02-01

    The purpose of the present study was to investigate the elemental composition, the microstructure, and the selected mechanical properties of high gold orthodontic brackets after intraoral aging. Thirty Incognito™ (3M Unitek, Bad Essen, Germany) lingual brackets were studied, 15 brackets as received (control group) and 15 brackets retrieved from different patients after orthodontic treatment. The surface of the wing area was examined by scanning electron microscopy (SEM). Backscattered electron imaging (BEI) was performed, and the elemental composition was determined by X-ray EDS analysis (EDX). After appropriate metallographic preparation, the mechanical properties tested were Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT), and Vickers hardness (HV). These properties were determined employing instrumented indentation testing (IIT) with a Vickers indenter. The results were statistically analyzed by unpaired t-test (α=0.05). There were no statistically significant differences evidenced in surface morphology and elemental content between the control and the experimental group. These two groups of brackets showed no statistically significant difference in surface morphology. Moreover, the mean values of HM, EIT, ηIT, and HV did not reach statistical significance between the groups (p>0.05). Under the limitations of this study, it may be concluded that the surface elemental content and microstructure as well as the evaluated mechanical properties of the Incognito™ lingual brackets remain unaffected by intraoral aging.

  17. Evaluation of Antibacterial Effects of Silver-Coated Stainless Steel Orthodontic Brackets.

    PubMed

    Arash, Valiollah; Keikhaee, Fatemeh; Rabiee, Sayed Mahmood; Rajabnia, Ramazan; Khafri, Soraya; Tavanafar, Saeid

    2016-01-01

    White spots and enamel demineralization around orthodontic brackets are among the most important complications resulting from orthodontic treatments. Since the antibacterial properties of metals and metallic particles have been well documented, the aim of this study was to assess the antibacterial effect of stainless steel orthodontic brackets coated with silver (Ag) particles. In this study, 40 standard metal brackets were divided into two groups of 20 cases and 20 controls. The brackets in the case group were coated with Ag particles using an electroplating method. Atomic force microscopy and scanning electron microscopy were used to assess the adequacy of the coating process. In addition, antibacterial tests, i.e., disk diffusion and direct contact tests were performed at three, six, 24, and 48 hours, and 15 and 30 days using a Streptococcus mutans strain. The results were analyzed using Student's t-test and repeated measures ANOVA. Analyses via SEM and AFM confirmed that excellent coatings were obtained by using an electroplating method. The groups exhibited similar behavior when subjected to the disk diffusion test in the agar medium. However, the bacterial counts of the Ag-coated brackets were, in general, significantly lower (P<0.001) than those of their non-coated counterparts. Brackets coated with Ag, via an electroplating method, exhibited antibacterial properties when placed in direct contact with Streptococcus mutans. This antibacterial effect persisted for 30 days after contact with the bacteria.

  18. Nanosilver coated orthodontic brackets: in vivo antibacterial properties and ion release.

    PubMed

    Metin-Gürsoy, Gamze; Taner, Lale; Akca, Gülçin

    2017-02-01

    Silver nanoparticles are currently utilized in the fields of dentistry. The aim of this study was to evaluate the antibacterial properties and ion release of nanosilver coated orthodontic brackets compared to conventional brackets. Nanosilver coating process was applied to standard orthodontic brackets placed on the mandibular incisors of Wistar Albino rats in the study group and conventional brackets in the control group. Dental plaque, mucosal vestibular smears, saliva, and blood samples were collected from rats at various days. The amounts of nanosilver ions in blood and saliva were measured and microbiological evaluation was made for Streptococcus mutans. For testing cariogenicity, all rats were sacrificed at the end of 75 days under anaesthesia. Teeth were stained using a caries indicator, then the caries ratio was assessed. Nanosilver coated orthodontic bracket favoured the inhibition of S.mutans on Day 30 and reduction of caries on the smooth surfaces. The nanosilver amounts in the saliva and serum samples were significantly higher in the study group on Day 7. It is suggested that nanosilver coated orthodontic brackets, as an antibacterial agent without patient compliance, could be helpful for the prevention of white spot lesions during fixed orthodontic treatment. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  19. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets.

    PubMed

    Cardoso, Mauricio de Almeida; Saraiva, Patrícia Pinto; Maltagliati, Liliana Ávila; Rhoden, Fernando Kleinübing; Costa, Carla Cristina Alvarenga; Normando, David; Capelozza Filho, Leopoldino

    2015-01-01

    The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI), gingival bleeding index (GBI) and clinical attachment level (CAL) were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional), two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL) in either one of the systems. No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored.

  20. Effects of chlorhexidine (gel) application on bacterial levels and orthodontic brackets during orthodontic treatment.

    PubMed

    Al-Bazi, Samar M; Abbassy, Mona A; Bakry, Ahmed S; Merdad, Leena A; Hassan, Ali H

    2016-01-01

    The objectives of this study were to evaluate the effects of applying 0.50% chlorhexidine (CHX) gel using the dental drug delivery system (3DS) on salivary Streptococcus mutans (S. mutans) and on the surface topography of metal and ceramic orthodontic brackets. The study involved 20 orthodontic patients with high levels of salivary S. mutans. The patients were treated with professional mechanical tooth cleaning followed by application of 0.50% CHX using individual trays (3DS). Salivary S. mutans levels were repeatedly measured 1, 2, 4, and 8 weeks post-treatment. In vitro study utilized forty ceramic and metallic brackets that were immersed in 0.50% CHX gel for 10 min, whereas another untreated forty brackets served as controls. The frictional resistances of stainless steel wires to the brackets before and after CHX treatment were recorded using a universal testing machine. Scanning electron microscopy was used to compare changes in the surface topography of brackets. Statistical analyses were used to determine the effect of CHX on bacterial count and to evaluate the effect of CHX on frictional resistance. According to the results of this study, S. mutans levels were reduced significantly (P < 0.05). There were no significant changes in the frictional resistance and surface topography of brackets before or after application of CHX. (J Oral Sci 58, 35-42, 2016).

  1. Damage of the Interface Between an Orthodontic Bracket and Enamel - the Effect of Some Elastic Properties of the Adhesive Material

    NASA Astrophysics Data System (ADS)

    Durgesh, B. H.; Alkheraif, A. A.; Al Sharawy, M.; Varrela, J.; Vallittu, P. K.

    2016-01-01

    The aim of this study was to investigate the magnitude of debonding stress of an orthodontic bracket bonded to the enamel with resin systems having different elastic properties. For the same purpose, sixty human premolars were randomly divided into four groups according to the adhesive system used for bonding brackets: G Fix flowable resin (GFI) with Everstick NET (ESN), GFI, G Aenial Universal Flow (GAU) with ESN, and GAU. The brackets were stressed in the occlusogingival direction on a universal testing machine. The values of debonding load and displacement were determined at the point of debonding. The elastic modulus of the tested materials was determined using nanoindentation. An analysis of variance showed a significant difference in the loads required to debond the bracket among the groups tested. The GAU group had the highest elastic modulus, followed by the GFI and ESN groups. ARI (Adhesive Remnant Index) scores demonstrated more remnants of the adhesive material on the bracket surface with adhesives having a higher elastic modulus. Taking into consideration results of the present in-vitro study, it can be concluded that the incorporation of a glass-fiber-reinforced composite resin (FRC) with a low elastic modulus between the orthodontic bracket and enamel increases the debonding force and strain more than with adhesive systems having a higher elastic modulus.

  2. Dentoalveolar mandibular changes with self-ligating versus conventional bracket systems: A CBCT and dental cast study

    PubMed Central

    de Almeida, Marcio Rodrigues; Futagami, Cristina; Conti, Ana Cláudia de Castro Ferreira; Oltramari-Navarro, Paula Vanessa Pedron; Navarro, Ricardo de Lima

    2015-01-01

    OBJECTIVE: The aim of the present study was to compare dentoalveolar changes in mandibular arch, regarding transversal measures and buccal bone thickness, in patients undergoing the initial phase of orthodontic treatment with self-ligating or conventional bracket systems. METHODS: A sample of 25 patients requiring orthodontic treatment was assessed based on the bracket type. Group 1 comprised 13 patients bonded with 0.022-in self-ligating brackets (SLB). Group 2 included 12 patients bonded with 0.022-in conventional brackets (CLB). Cone-beam computed tomography (CBCT) scans and a 3D program (Dolphin) assessed changes in transversal width of buccal bone (TWBB) and buccal bone thickness (BBT) before (T1) and 7 months after treatment onset (T2). Measurements on dental casts were performed using a digital caliper. Differences between and within groups were analyzed by Student's t-test; Pearson correlation coefficient was also calculated. RESULTS: Significant mandibular expansion was observed for both groups; however, no significant differences were found between groups. There was significant decrease in mandibular buccal bone thickness and transversal width of buccal bone in both groups. There was no significant correlation between buccal bone thickness and dental arch expansion. CONCLUSIONS: There were no significant differences between self-ligating brackets and conventional brackets systems regarding mandibular arch expansion and changes in buccal bone thickness or transversal width of buccal bone. PMID:26154456

  3. A subjective comparison of two lingual bracket systems.

    PubMed

    Stamm, Thomas; Hohoff, Ariane; Ehmer, Ulrike

    2005-08-01

    The purpose of this prospective, longitudinal study was to compare the influence of two lingual bracket systems on subjective oral comfort, speech, mastication and oral hygiene. Forty-two native speakers of standard German (32 females, 10 males; mean age 27.1 years, standard deviation 12.2) were enrolled and completed a standardized questionnaire directly before insertion of lingual brackets (T0), within 24 hours of bond-up (T1) and 3 months (+/- 1 week) later (T2). Eighteen of the patients were treated with prefabricated brackets (Ormco, seventh generation) (PB group) and 24 with customized brackets (Incognito) (CB group). While no significant intergroup differences were recorded at any of the times with respect to tongue position, conversation pattern, swallowing or oral hygiene, the CB group experienced significantly fewer tongue space restrictions, speech disturbances and impairments in chewing and biting than the PB group at T1 and T2. At T2, pressure sores, reddening or lesions to the tongue were recorded significantly less often in the CB group than in the PB group. This enhanced patient comfort in the CB group was attributed to the smaller dimensions of the customized brackets. This aspect could play a role in attracting more patients to lingual orthodontics in the future. Information given to the patient on the duration and extent of the restrictions associated with lingual orthodontics must be differentiated according to the bracket system used.

  4. Mechanical effects of third-order movement in self-ligated brackets by the measurement of torque expression.

    PubMed

    Major, Thomas W; Carey, Jason P; Nobes, David S; Heo, Giseon; Major, Paul W

    2011-01-01

    Axial rotation of orthodontic wire produces buccal or lingual root movement and is often referred to as third-order movement or "torque expression." The objective of this study was to quantify torque expression in 3 self-ligation bracket systems (Damon Q, Ormco, Orange, Calif; In-Ovation R, GAC, Bohemia, NY; and Speed, Strite Industries, Cambridge, Ontario, Canada) during loading and unloading. A stepper motor was used to rotate a wire in a fixed bracket slot from -15° to 63° in 3° increments, and then back to -15°. The bracket was mounted on top of a load cell that measured forces and moments in all directions. Damon's and In-Ovation's maximum average torque values at 63° were 105 and 113 Nmm, respectively. Many Speed brackets experienced premature loss of torque between 48° and 63°, and the average maximum was 82 Nmm at 54°. The torque plays for Damon, In-Ovation, and Speed were 11.3°, 11.9°, and 10.8°, respectively. Generally, In-Ovation expressed the most torque at a given angle of twist, followed by Damon and then Speed. However, there was no significant difference between brackets below 34 Nmm of torque. From a clinical perspective, the torque plays between brackets were virtually indistinguishable. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  5. 37 CFR 1.217 - Publication of a redacted copy of an application.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... translation is accurate; (3) A marked-up copy of the application showing the redactions in brackets; and (4) A... brackets; and (ii) A copy of each submission previously filed by the applicant including any desired... material in brackets. (2) In addition to providing the submission required by paragraphs (c) and (d)(1) of...

  6. Comparison of deflection forces of esthetic archwires combined with ceramic brackets*

    PubMed Central

    MATIAS, Murilo; de FREITAS, Marcos Roberto; de FREITAS, Karina Maria Salvatore; JANSON, Guilherme; HIGA, Rodrigo Hitoshi; FRANCISCONI, Manoela Fávaro

    2018-01-01

    Abstract Coated archwires and ceramic brackets have been developed to improve facial esthetics during orthodontic treatment. However, their mechanical behavior has been shown to be different from metallic archwires and brackets. Therefore, the aim of this study was to compare the deflection forces in coated nickel-titanium (NiTi) and esthetic archwires combined with ceramic brackets. Material and Methods Non-coated NiTi (NC), rhodium coated NiTi (RC), teflon coated NiTi (TC), epoxy coated NiTi (EC), fiber-reinforced polymer (FRP), and the three different conventional brackets metal-insert polycrystalline ceramic (MI-PC), polycrystalline ceramic (PC) and monocrystalline ceramic (MC) were used. The specimens were set up on a clinical simulation device and evaluated in a Universal Testing Machine (Instron). An acrylic device, representative of the right maxillary central incisor was buccolingually activated and the unloading forces generated were recorded at 3, 2, 1 and 0.5 mm. The speed of the testing machine was 2 mm/min. ANOVA and Tukey tests were used to compare the different archwires and brackets. Results The brackets presented the following decreasing force ranking: monocrystalline, polycrystalline and polycrystalline metal-insert. The decreasing force ranking of the archwires was: rhodium coated NiTi (RC), non-coated NiTi (NC), teflon coated NiTi (TC), epoxy coated NiTi (EC) and fiber-reinforced polymer (FRP). At 3 mm of unloading the FRP archwire had a plastic deformation and produced an extremely low force in 2; 1 and 0.5 mm of unloading. Conclusion Combinations of the evaluated archwires and brackets will produce a force ranking proportional to the combination of their individual force rankings. PMID:29451650

  7. Ion release from orthodontic brackets in 3 mouthwashes: an in-vitro study.

    PubMed

    Danaei, Shahla Momeni; Safavi, Afsaneh; Roeinpeikar, S M Mehdi; Oshagh, Morteza; Iranpour, Shiva; Omidkhoda, Maryam; Omidekhoda, Maryam

    2011-06-01

    Stainless steel orthodontic brackets can release metal ions into the saliva. Fluoridated mouthwashes are often recommended to orthodontic patients to reduce the risk of white-spot lesions around their brackets. However, little information is available regarding the effect of different mouthwashes in ion release of orthodontic brackets. The purpose of this study was to measure the amount of metal ion release from orthodontic brackets when kept in different mouthwashes. One hundred sixty stainless steel brackets (0.022-in, 3M Unitek, Monrovia, Calif) were divided randomly into 4 equal groups and immersed in Oral B (Procter & Gamble, Weybridge, United Kingdom), chlorhexidine (Shahdaru Labratories, Tehran, Iran), and Persica (Poursina Pharmaceutical Laboratories, Tehran, Iran) mouthwashes and distilled deionized water and incubated at 37°C for 45 days. Nickel, chromium, iron, copper, and manganese released from the orthodontic brackets were measured with an inductively coupled plasma spectrometer. For statistical analysis, 1-way analysis of variance (ANOVA) and the Duncan multiple-range tests were used. The results showed that ion release in deionized water was significantly (P <0.05) higher than in the 3 mouthwashes. Higher ion release was found with chlorhexidine compared with the other 2 mouthwashes. There was no significant difference (P >0.05) in nickel, chromium, iron, and copper ion release in the Oral B and Persica mouthwashes. The level of manganese release was significantly different in all 4 groups. If ion release is a concern, Oral B and Persica mouthwashes might be better options than chlorhexidine for orthodontic patients with stainless steel brackets. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. The effect of bracket ligation on the periodontal status of adolescents undergoing orthodontic treatment. A systematic review and meta-analysis.

    PubMed

    Arnold, Sina; Koletsi, Despina; Patcas, Raphael; Eliades, Theodore

    2016-11-01

    This systematic review aimed to critically appraise the evidence regarding the effect of bracket ligation type on the periodontal conditions of adolescents undergoing orthodontic treatment. Search terms included randomized controlled trial (RCTs), controlled clinical trials, ligation, bracket, periodontal, inflammation. Risk of bias assessment was made using the Cochrane risk of bias tool and the quality of evidence was assessed with GRADE. Electronic Database search of published and unpublished literature was performed without language restriction in May 25, 2016 (MEDLINE via Pubmed, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Clinical Trials.gov and National Research Register). Of 140 articles initially retrieved, 8 were eligible for inclusion in the systematic review, while 4 RCTs with unclear risk of bias were included in the quantitative synthesis, all comparing self-ligating to conventional steel ligated brackets. Random effects meta-analyses were implemented. At 4-6 weeks after bracket placement there was no evidence to support the use of either type of bracket for achieving improved plaque- (PI) and gingival index (GI). At 3-6 months, there was scarce evidence of greater PI increase for conventional brackets. GI and pocket depth pooled estimates did not reveal significant differences between the two systems. The quality of the evidence was moderate according to GRADE for all outcomes. Overall, non-significant differences on the periodontal status of adolescents undergoing orthodontic treatment with either conventional or self-ligating brackets were detected. The periodontal status of adolescents undergoing orthodontic treatment is of considerable importance. The synthesis of the available evidence on oral hygiene related factors will provide insights to best clinical practice during the course of orthodontic treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Comparison of deflection forces of esthetic archwires combined with ceramic brackets.

    PubMed

    Matias, Murilo; Freitas, Marcos Roberto de; Freitas, Karina Maria Salvatore de; Janson, Guilherme; Higa, Rodrigo Hitoshi; Francisconi, Manoela Fávaro

    2018-01-01

    Coated archwires and ceramic brackets have been developed to improve facial esthetics during orthodontic treatment. However, their mechanical behavior has been shown to be different from metallic archwires and brackets. Therefore, the aim of this study was to compare the deflection forces in coated nickel-titanium (NiTi) and esthetic archwires combined with ceramic brackets. Material and Methods Non-coated NiTi (NC), rhodium coated NiTi (RC), teflon coated NiTi (TC), epoxy coated NiTi (EC), fiber-reinforced polymer (FRP), and the three different conventional brackets metal-insert polycrystalline ceramic (MI-PC), polycrystalline ceramic (PC) and monocrystalline ceramic (MC) were used. The specimens were set up on a clinical simulation device and evaluated in a Universal Testing Machine (Instron). An acrylic device, representative of the right maxillary central incisor was buccolingually activated and the unloading forces generated were recorded at 3, 2, 1 and 0.5 mm. The speed of the testing machine was 2 mm/min. ANOVA and Tukey tests were used to compare the different archwires and brackets. Results The brackets presented the following decreasing force ranking: monocrystalline, polycrystalline and polycrystalline metal-insert. The decreasing force ranking of the archwires was: rhodium coated NiTi (RC), non-coated NiTi (NC), teflon coated NiTi (TC), epoxy coated NiTi (EC) and fiber-reinforced polymer (FRP). At 3 mm of unloading the FRP archwire had a plastic deformation and produced an extremely low force in 2; 1 and 0.5 mm of unloading. Conclusion Combinations of the evaluated archwires and brackets will produce a force ranking proportional to the combination of their individual force rankings.

  10. Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination.

    PubMed

    Khanehmasjedi, Mashallah; Naseri, Mohammad Ali; Khanehmasjedi, Samaneh; Basir, Leila

    2017-02-01

    This study compared the shear bond strength of metallic brackets bonded with Single Bond and Assure bonding agents under dry and saliva-contamination conditions. Sixty sound premolar teeth were selected, and stainless-steel brackets were bonded on enamel surfaces with Single Bond and Assure bonding agents under dry condition or with saliva contamination. Shear bond strength values of brackets were measured in a universal testing machine. The adhesive remnant index scores were determined after debonding of the brackets under a stereomicroscope. One-way analysis of variance (ANOVA) was used to analyze bond strength. Two-by-two comparisons were made with post hoc Tukey tests (p<0.001). Frequencies of adhesive remnant index scores were analyzed by Kruskal-Wallis test. Bond strength values of brackets to tooth structure were 9.29±8.56 MPa and 21.25±8.93 MPa with the use of Assure resin bonding agent under saliva-contamination and dry conditions, respectively. These values were 10.13±6.69 MPa and 14.09±6.6 MPa, respectively, under the same conditions with the use of Single Bond adhesive. Contamination with saliva resulted in a significant decrease in the bond strength of brackets to tooth structure with the application of Assure adhesive resin (p<0.001). There were no significant differences in the adhesive remnant index scores between the study groups. Application of Single Bond and Assure bonding agents resulted in adequate bond strength of brackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared with dry conditions. Copyright © 2016. Published by Elsevier Taiwan LLC.

  11. Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners

    PubMed Central

    Rollins, Nancy K.; Liang, Hui; Park, Yong Jong

    2015-01-01

    Purpose: Most orthodontic appliances are made of stainless steel materials and induce severe magnetic susceptibility artifacts in brain MRI. In an effort for correcting these artifacts, it is important to know the value of induced magnetic moments in all parts of orthodontic appliances. In this study, the induced magnetic moment of stainless steel orthodontic brackets, molar bands, and arch-wires from several vendors is measured. Methods: Individual stainless steel brackets, molar bands, and short segments of arch-wire were positioned in the center of spherical flask filled with water through a thin plastic rod. The induced magnetic moment at 1.5 T was determined by fitting the B0 map to the z-component of the magnetic dipole field using a computer routine. Results: The induced magnetic moment at 1.5 T was dominated by the longitudinal component mz, with a small contribution from the transverse components. The mz was insensitive to the orientation of the metal parts. The orthodontic brackets collectively dominated the magnetic dipole moment in orthodontic appliances. In brackets from six vendors, the total induced mz from 20 brackets for nonmolar teeth ranged from 0.108 to 0.158 (median 0.122) A ⋅ m2. The mz in eight molar bands with bracket attachment from two vendors ranged from 0.0004 to 0.0166 (median 0.0035) A ⋅ m2. Several full length arch wires had induced magnetic moment in the range of 0.006–0.025 (median 0.015) A ⋅ m2. Conclusions: Orthodontic brackets collectively contributed most to the total magnetic moment. Different types of brackets, molar bands, and arch wires all exhibit substantial variability in the induced magnetic moment. PMID:26429261

  12. Thermal debonding of ceramic brackets: an in vitro study.

    PubMed

    Crooks, M; Hood, J; Harkness, M

    1997-02-01

    Thermal debonding has been developed to overcome the problems of enamel damage and high forces when debonding ceramic orthodontic brackets. However, the temperature changes with thermal debonding have the potential to damage the tooth tissues. The principal aims of this study are, first, to investigate the effects of resin type, resin thickness, and debonding force on the temperature changes in human premolars during thermal debonding of ceramic brackets and, second, to record the sites of bond failure and damage to the tooth surface. Ceramic brackets were attached to each specimen by using one of four types of bonding resin in a controlled thick or thin resin layer. The ceramic debonding unit (Dentaurum, Pforzheim, Germany) was used to thermally debond the brackets with either a 40 or 80 Nmm torsional force. Higher temperature changes at the pulpal wall (> 10 degrees C in some 40 Nmm torsional force specimens) always occurred with Concise (3M Dental Products, St. Paul, Minn.) and Transbond (Unitek/3M Dental Products, Monrovia, Calif.) resins, and lower temperature changes (< 5 degrees C) with Quasar (Rocky Mountain Orthodontics, Denver, Colo.) and Ortho. B.S. (Dentaurum, Pforzheim, Germany) resins. In general, resin thickness was not significantly associated with buccal surface or pulpal wall temperature changes. However, temperature changes at the pulpal wall were significantly associated with the temperature changes at the buccal surface (r = 0.76), with the temperature of the thermal debonder blade for thin resin layer specimens (r = 0.50), and the time required to debond the bracket for both thick (r = 0.74) and thin (r = 0.63) resin layer specimens. In most specimens, the site of bond failure occurred at the bracket-resin interface. There was no evidence of enamel damage after bracket removal.

  13. Force system generated by elastic archwires with vertical V bends: a three-dimensional analysis.

    PubMed

    Upadhyay, Madhur; Shah, Raja; Peterson, Donald; Asaki, Takafumi; Yadav, Sumit; Agarwal, Sachin

    2017-04-01

    Our previous understanding of V-bend mechanics is primarily from two-dimensional (2D) analysis of archwire bracket interactions in the second order. These analyses do not take into consideration the three-dimensional (3D) nature of orthodontic appliances involving the third order. To quantify the force system generated in a 3D two bracket set up involving the molar and incisors with vertical V-bends. Maxillary molar and incisor brackets were arranged in a dental arch form and attached to load cells capable of measuring forces and moments in all three planes (x, y, and z) of space. Symmetrical V-bends (right and left sides) were placed at 11 different locations along rectangular beta-titanium archwires of various sizes at an angle of 150degrees. Each wire was evaluated for the 11 bend positions. Specifically, the vertical forces (Fz) and anterio-posterior moments (Mx) were analysed. Descriptive statistics were used to interpret the results. With increasing archwire size, Fz and Mx increased at the two brackets (P < 0.05). The vertical forces were linear and symmetric in nature, increasing in magnitude as the bends moved closer to either bracket. The Mx curves were asymmetric and non-linear displaying higher magnitudes for molar bracket. As the bends were moved closer to either bracket a distinct flattening of the incisor Mx curve was noted, implying no change in its magnitude. This article provides critical information on V-bend mechanics involving second order and third order archwire-bracket interactions. A model for determining this force system is described that might allow for easier translation to actual clinical practice. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  14. A retrospective survey of the causes of bracket- and tube-bonding failures.

    PubMed

    Roelofs, Tom; Merkens, Nico; Roelofs, Jeroen; Bronkhorst, Ewald; Breuning, Hero

    2017-01-01

    To investigate the causes of bonding failures of orthodontic brackets and tubes and the effect of premedicating for saliva reduction. Premedication with atropine sulfate was administered randomly. Failure rate of brackets and tubes placed in a group of 158 consecutive patients was evaluated after a mean period of 67 weeks after bonding. The failure rate in the group without atropine sulfate premedication was 2.4%. In the group with premedication, the failure rate was 2.7%. The Cox regression analysis of these groups showed that atropine application did not lead to a reduction in bond failures. Statistically significant differences in the hazard ratio were found for the bracket regions and for the dental assistants who prepared for the bonding procedure. Premedication did not lead to fewer bracket failures. The roles of the dental assistant and patient in preventing failures was relevant. A significantly higher failure rate for orthodontic appliances was found in the posterior regions.

  15. Bond strengths evaluation of laser ceramic bracket debonding

    NASA Astrophysics Data System (ADS)

    Dostalová, T.; Jelinková, H.; Šulc, J.; Němec, M.; Fibrich, M.; Jelínek, M.; Michalík, P.; Bučková, M.

    2012-09-01

    Ceramic brackets often used for an orthodontic treatment can lead to problems such as enamel tear outs because of their low fracture resistance and high bond strengths. Therefore the aim of our study was to investigate the positive laser radiation effect on bracket debonding. Moreover, the influence of the enamel shape surface under the bracket and laser radiation power on the debonding strength was investigated. The source of the radiation was the longitudinally diode-pumped Tm:YAP laser operating at 1997 nm. To eliminate the tooth surface roughness the flat enamel surface was prepared artificially and the bracket was bonded on it. The debonding was accomplished by Tm:YAP laser radiation with different the power value while recording the temperature rise in the pulp. To simulate the debonding process in vivo the actual bond strength was measured by the digital force gauge. The results were analyzed by scanning electron microscope.

  16. Analysis of maxillary arch force/couple systems for a simulated high canine malocclusion: Part 1. Passive ligation.

    PubMed

    Fok, Jonathan; Toogood, Roger W; Badawi, Hisham; Carey, Jason P; Major, Paul W

    2011-11-01

    To better understand the mechanics of bracket/archwire interaction through analysis of force and couple distribution along the maxillary arch. An orthodontic simulator was utilized to study high canine malocclusion. Force/couple distributions, referenced to the center of resistance (CR) of each tooth, produced by passive ligation brackets and round wire were measured. Tests were repeated for 12 bracket sets with 12 wires per set. Propagation of the force/couple systems around the arch was minimal. Binding was observed only on the teeth adjacent to the displaced canine. For most of the teeth, reduced resistance to sliding of the passive ligation bracket yielded minimal tangential and normal forces at the bracket and contributed to lower moments at CR. Some potential mechanical advantages of passive ligation systems are suggested for the case studied. In particular, limited propagation around the arch reduces the occurrence of unwanted force/couple systems.

  17. Reduction in static friction by deposition of a homogeneous diamond-like carbon (DLC) coating on orthodontic brackets.

    PubMed

    Akaike, Shun; Hayakawa, Tohru; Kobayashi, Daishiro; Aono, Yuko; Hirata, Atsushi; Hiratsuka, Masanori; Nakamura, Yoshiki

    2015-01-01

    In orthodontics, a reduction in static friction between the brackets and wire is important to enable easy tooth movement. The aim of this study was to examine the effects of a homogeneous diamond-like carbon (DLC) coating on the whole surfaces of slots in stainless steel orthodontic brackets on reducing the static friction between the brackets and the wire. The DLC coating was characterized using Raman spectroscopy, surface roughness and contact angle measurements, and SEM observations. Rectangular stainless steel and titanium-molybdenum alloy wires with two different sizes were employed, and the static friction between the brackets and wire was measured under dry and wet conditions. The DLC coating had a thickness of approximately 1.0 μm and an amorphous structure was identified. The results indicated that the DLC coating always led to a reduction in static friction.

  18. Development of a Notational Analysis System for Selected Soccer Skills of a Women's College Team

    ERIC Educational Resources Information Center

    Thomas, Camille; Fellingham, Gilbert; Vehrs, Pat

    2009-01-01

    The purposes of this study were to develop a notational system to evaluate passing, dribbling, first touch, and individual defensive skills as they relate to success during women's soccer games and to develop a statistical model to weigh the importance of each skill on creating scoring opportunities. Sequences of skills in ten games of a National…

  19. The Effects of Aural versus Notated Instructional Materials on Achievement and Self-Efficacy in Jazz Improvisation

    ERIC Educational Resources Information Center

    Watson, Kevin E.

    2010-01-01

    The purpose of the present study was to investigate the effects of aural versus notated pedagogical materials on achievement and self-efficacy in instrumental jazz improvisation performance. A secondary purpose of this study was to investigate how achievement and self-efficacy may be related to selected experience variables. The sample for the…

  20. "The Spiral Model for the Development of Coordination": A Learning Model Based on Eshkol-Wachman Movement Notation (EWMN)

    ERIC Educational Resources Information Center

    Al-Dor, Nira

    2006-01-01

    The objective of this study is to present "The Spiral Model for the Development of Coordination" (SMDC), a learning model that reflects the complexity and possibilities embodied in the learning of movement notation Eshkol-Wachman (EWMN), an Israeli invention. This model constituted the infrastructure for a comprehensive study that examined the…

  1. Assessing Resource Value and Relationships Between Objectives in Effects-Based Operations

    DTIC Science & Technology

    2006-03-01

    terms of a set of desired end states for the campaign’s system of systems . Value theory was used to identify the resource’s value in terms of the direct...2-1 2.3. System of Systems Analysis (SoSA) Definitions and Notation .................. 2-6 2.4. Mathematical Notation to...Describe an Enemy System ............................... 2-7 2.5. Weighting Techniques

  2. 26 CFR 301.6110-5 - Notice and time requirements; actions to restrain disclosure; actions to obtain additional...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) any third-party communication notations required to be placed pursuant to § 301.6110-4(a) on the face... a written determination on which a third-party communication notation has been placed pursuant to... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Notice and time requirements; actions to...

  3. Cognitive Development of Applying the Chain Rule through Three Worlds of Mathematics

    ERIC Educational Resources Information Center

    Kabael, Tangul Uygur

    2010-01-01

    The derivative of a composite function, taken with the chain rule is one of the important notions in calculus. This paper describes a study conducted in Turkey that shows that the chain rule was given with the formula in function notation and/or the Leibniz notation without relating these formulas to life-related problem situations in the…

  4. A Review. A Real-Time Microcomputer-Assisted System for Translating Aural, Monophonic Tones into Music Notation as an Aid in Sight-Singing.

    ERIC Educational Resources Information Center

    Higgins, William R.

    1987-01-01

    Reviews a dissertation in which the problems of real-time pitch detection by computer were studied in an attempt to develop a learning tool for sightsinging students. Specialized hardware and software were developed to discriminate aural pitches and to display them in real-time using standard notation. (BSR)

  5. A Non-technical User-Oriented Display Notation for XACML Conditions

    NASA Astrophysics Data System (ADS)

    Stepien, Bernard; Felty, Amy; Matwin, Stan

    Ideally, access control to resources in complex IT systems ought to be handled by business decision makers who own a given resource (e.g., the pay and benefits section of an organization should decide and manage the access rules to the payroll system). To make this happen, the security and database communities need to develop vendor-independent access management tools, useable by decision makers, rather than technical personnel detached from a given business function. We have developed and implemented such tool, based on XACML. The XACML is an important emerging tool for managing complex access control applications. As a formal notation, based on an XML schema representing the grammar of a given application, XACML is precise and non-ambiguous. But this very property puts it out of reach of non-technical users. We propose a new notation for displaying and editing XACML rules that is independent of XML, and we develop an editor for it. Our notation combines a tree representation of logical expressions with an accessible natural language layer. Our early experience indicates that such rules can be grasped by non-technical users wishing to develop and control rules for accessing their own resources.

  6. 15 CFR 744.8 - Restrictions on exports and reexports to persons designated pursuant to Executive Order 13382...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Chapter V with the bracketed suffix [NPWMD]. This section imposes export and reexport license requirements... Chapter V with the bracketed suffix [NPWMD]. (2) BIS authorization. (i) To avoid duplication, U.S. persons... in Appendix A to 31 CFR Chapter V with the bracketed suffix [NPWMD] of an item subject to the EAR. If...

  7. 15 CFR 744.8 - Restrictions on exports and reexports to persons designated pursuant to Executive Order 13382...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... chapter V with the bracketed suffix [NPWMD]. This section imposes export and reexport license requirements... chapter V with the bracketed suffix [NPWMD]. (2) BIS authorization. (i) To avoid duplication, U.S. persons... in appendix A to 31 CFR chapter V with the bracketed suffix [NPWMD] of an item subject to the EAR. If...

  8. Nearly associative deformation quantization

    NASA Astrophysics Data System (ADS)

    Vassilevich, Dmitri; Oliveira, Fernando Martins Costa

    2018-04-01

    We study several classes of non-associative algebras as possible candidates for deformation quantization in the direction of a Poisson bracket that does not satisfy Jacobi identities. We show that in fact alternative deformation quantization algebras require the Jacobi identities on the Poisson bracket and, under very general assumptions, are associative. At the same time, flexible deformation quantization algebras exist for any Poisson bracket.

  9. Wronski Brackets and the Ferris Wheel

    NASA Astrophysics Data System (ADS)

    Martin, Keye

    2005-11-01

    We connect the Bayesian order on classical states to a certain Lie algebra on C^infty[0,1]. This special Lie algebra structure, made precise by an idea we introduce called a Wronski bracket, suggests new phenomena the Bayesian order naturally models. We then study Wronski brackets on associative algebras, and in the commutative case, discover the beautiful result that they are equivalent to derivations.

  10. Does It Help to Use Mathematically Superfluous Brackets When Teaching the Rules for the Order of Operations?

    ERIC Educational Resources Information Center

    Gunnarsson, Robert; Sönnerhed, Wang Wei; Hernell, Bernt

    2016-01-01

    The hypothesis that mathematically superfluous brackets can be useful when teaching the rules for the order of operations is challenged. The idea of the hypothesis is that with brackets it is possible to emphasize the order priority of one operation over another. An experiment was conducted where expressions with mixed operations were studied,…

  11. Prototype to measure bracket debonding force in vivo.

    PubMed

    Tonus, Jéssika Lagni; Manfroi, Fernanda Borguetti; Borges, Gilberto Antonio; Grigolo, Eduardo Correa; Helegda, Sérgio; Spohr, Ana Maria

    2017-02-01

    Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. According to Student's t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets.

  12. [Enamel damage depending on the method of bracket removal].

    PubMed

    Fischer-Brandies, H; Kremers, L; Reicheneder, C; Kluge, G; Hüsler, K

    1993-04-01

    Two different methods of removing brackets, on the one side by torsion and on the other by bending, were compared for the purpose of analyzing the respective enamel lesions. Each test group consisted of 19 extracted human molars with metal brackets attached to the molars by means of the "concise etching technique". Bracket removal was standardized through the use of a Wolpert "Universalprüfmaschine TZZ 707" with modified torsion and bending mechanism. A scanning electron microscope was used to analyze the enamel surface. When using the torsion method, the mean extension of the enamel lesions was 48.3% of the adhesive free enamel surface. These lesions often reached into the deeper enamel layers and were mainly to be found on the broad side of the bonded area. On the other hand, when using the bending method, the enamel lesions were less frequent. They were mainly superficial and were confined almost exclusively to the pressure zones. The stress required to remove the brackets and the stress distribution were calculated on mechanical models and these results corresponded well with the enamel lesions observed on the molars. It can thus be concluded that the method of removing brackets is clinically relevant in relation to enamel lesions.

  13. Evaluation of a new nano-filled restorative material for bonding orthodontic brackets.

    PubMed

    Bishara, Samir E; Ajlouni, Raed; Soliman, Manal M; Oonsombat, Charuphan; Laffoon, John F; Warren, John

    2007-01-01

    To compare the shear bond strength of a nano-hybrid restorative material, Grandio (Voco, Cuxhaven, Germany), to that of a traditional adhesive material (Transbond XT; 3M Unitek, Monrovia, CA, USA) when bonding orthodontic brackets. Forty teeth were randomly divided into 2 groups: 20 teeth were bonded with the Transbond adhesive system and the other 20 teeth with the Grandio restorative system, following manufacturer's instructions. Student t test was used to compare the shear bond strength of the 2 systems. Significance was predetermined at P 5 .05. The t test comparisons (t = 0.55) of the shear bond strength between the 2 adhesives indicated the absence of a significant (P = .585) difference. The mean shear bond strength for Grandio was 4.1 +/- 2.6 MPa and that for Transbond XT was 4.6 +/- 3.2 MPa. During debonding, 3 of 20 brackets (15%) bonded with Grandio failed without registering any force on the Zwick recording. None of the brackets bonded with Transbond XT had a similar failure mode. The newly introduced nano-filled composite materials can potentially be used to bond orthodontic brackets to teeth if its consistency can be more flowable to readily adhere to the bracket base.

  14. Therapeutic efficacy of self-ligating brackets: A systematic review.

    PubMed

    Dehbi, Hasnaa; Azaroual, Mohamed Faouzi; Zaoui, Fatima; Halimi, Abdelali; Benyahia, Hicham

    2017-09-01

    Over the last few years, the use of self-ligating brackets in orthodontics has progressed considerably. These systems have been the subject of numerous studies with good levels of evidence making it possible to evaluate their efficacy and efficiency compared to conventional brackets. The aim of this study was to evaluate the therapeutic efficacy of self-ligating brackets by means of a systematic review of the scientific literature. A systematic study was undertaken in the form of a recent search of the electronic Pubmed database, oriented by the use of several keywords combined by Boolean operators relating to the therapeutic efficacy of self-ligating brackets through the study of tooth alignment, space closure, expansion, treatment duration and degree of discomfort. The search was limited to randomized controlled studies, and two independent readers identified studies corresponding to the selection criteria. The chosen articles comprised 20 randomized controlled trials. The studies analyzed revealed the absence of significant differences between the two types of system on the basis of the clinical criteria adopted, thereby refuting the hypothesis of the superiority of self-ligating brackets over conventional systems. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  15. Factors Affecting the Shear Bond Strength of Orthodontic Brackets - a Review of In Vitro Studies.

    PubMed

    Bakhadher, Waleed; Halawany, Hassan; Talic, Nabeel; Abraham, Nimmi; Jacob, Vimal

    2015-01-01

    The adhesive material used to bond orthodontic brackets to teeth should neither fail during the treatment period, resulting in treatment delays, untoward expenses or patient inconvenience nor should it damage the enamel on debonding at the end of the treatment. Although the effectiveness of a bonding system and any unfavorable effects on the enamel may be studied by conducting in-vivo studies, it is nearly impossible to independently analyze different variables that influence a specific bonding system in the oral environment. In-vitro studies, on the other hand, may utilize more standardized protocols for testing different bonding systems and materials available. Thus, the present review focused attention on in-vitro studies and made an attempt to discuss material-related, teeth-related (fluorotic vs non-fluorotic teeth) and other miscellaneous factors that influences the shear bond strength of orthodontic brackets. Within the limitations of this review, using conventional acid-etch technique, ceramic brackets and bonding to non-fluorotic teeth was reported to have a positive influence on the shear bond strength of orthodontic brackets, but higher shear bond strength found on using ceramic brackets can be dangerous for the enamel.

  16. Laboratory evaluations on thermal debonding of ceramic brackets.

    PubMed

    Sernetz, F; Kraut, J

    1991-01-01

    The purpose of this laboratory study was to define the working parameters and physiological safety and efficacy of the Dentaurum Ceramic Debonding Unit. Extracted mandibular incisors were utilized because of their low thermal mass and low heat sensitivity. The teeth were embedded in plastic and placed on a turning force measuring apparatus. An electrothermal element was placed in the pulp chamber (filled with a conducting paste). The thermoelement temperature was registered on y-t recorder as was the turning momentum required to remove the ceramic brackets with the Dentaurum Ceramic Debonding Unit. Ceramic brackets from GAC (Allure III), Unitek (Transcend) and Dentaurum (Fascination) using one and two component adhesives (Monolok, Concise), were tested. Scanning electron microscopic views taken after debonding showed predictable (and favorable) adhesive failure at the bracket base/resin interface. No enamel damage was demonstrated. All brackets were removable under three seconds with a clinically reproducible turning force of 85-100 Nmm allowing for intrapulpal temperature increases under the 5 degrees C biocompatible threshold. The Dentaurum Ceramic Debonding Unit provided a safe, reliable, efficient modality of removing ceramic brackets while maintaining a physiologically acceptable rise in pulpal temperature without damage to tooth enamel or pulpal tissue.

  17. Influence of spatio-temporal resource availability on mushroom mite diversity.

    PubMed

    Okabe, Kimiko

    2013-11-01

    Although biodiversity in nature is of fundamental importance because it improves the sustainability of ecosystems, communities of microscopic organisms are generally excluded from conservation targets for biodiversity. Here, I hypothesize that mushroom mite species richness is correlated with both spatial (i.e., mushroom size) and temporal (i.e., longevity of fruiting bodies) resource availability. I collected fruiting bodies in an old-growth forest over 4 years to collect mites and insects inhabiting the mushrooms. Mites were collected from 47 % of the fruiting bodies and approximately 60 % of the mite species were collected only once. Mite species richness was significantly correlated with the availability of long-lasting fruiting bodies. For example, bracket fungi contained more mite species than ephemeral fruiting bodies. Insect presence was also correlated with mushroom mite richness, probably as phoretic hosts and food resources for predacious mites. On the other hand, mushroom size seemed to be less important; small fruiting bodies sometimes harbored several mite species. Although mite species richness was correlated with mushroom species richness, mushroom specificity by mites was not clear except for a preference for long-lasting fruiting bodies. Therefore, I suggest that a constant supply of coarse woody debris is crucial for maintaining preferred resources for mushroom mites (e.g., bracket fungi) and their associated insects (mycophilous and possibly saproxylic insects).

  18. Evaluation of Antibacterial Effects of Silver-Coated Stainless Steel Orthodontic Brackets

    PubMed Central

    Arash, Valiollah; Keikhaee, Fatemeh; Rajabnia, Ramazan; Khafri, Soraya; Tavanafar, Saeid

    2016-01-01

    Objectives: White spots and enamel demineralization around orthodontic brackets are among the most important complications resulting from orthodontic treatments. Since the antibacterial properties of metals and metallic particles have been well documented, the aim of this study was to assess the antibacterial effect of stainless steel orthodontic brackets coated with silver (Ag) particles. Materials and Methods: In this study, 40 standard metal brackets were divided into two groups of 20 cases and 20 controls. The brackets in the case group were coated with Ag particles using an electroplating method. Atomic force microscopy and scanning electron microscopy were used to assess the adequacy of the coating process. In addition, antibacterial tests, i.e., disk diffusion and direct contact tests were performed at three, six, 24, and 48 hours, and 15 and 30 days using a Streptococcus mutans strain. The results were analyzed using Student’s t-test and repeated measures ANOVA. Results: Analyses via SEM and AFM confirmed that excellent coatings were obtained by using an electroplating method. The groups exhibited similar behavior when subjected to the disk diffusion test in the agar medium. However, the bacterial counts of the Ag-coated brackets were, in general, significantly lower (P<0.001) than those of their non-coated counterparts. Conclusions: Brackets coated with Ag, via an electroplating method, exhibited antibacterial properties when placed in direct contact with Streptococcus mutans. This antibacterial effect persisted for 30 days after contact with the bacteria. PMID:27536328

  19. Multibracket appliance: impression defaults and their reduction by blocking-out  -  a three-dimensional study.

    PubMed

    Wriedt, Susanne; Foersch, Moritz; Muhle, Jan Daniel; Schmidtmann, Irene; Wehrbein, Heinrich

    2016-03-01

    This study examines accuracy of dental impressions and following plaster models taken during treatment with fixed appliances. A maxillary typodont was provided with brackets. Three examiners took impressions three times each of the variants: brackets only, archwire fixed by alastics, ligatures or Kobayashi-hooks, and brackets and archwire covered completely or just on the gingival side by protection or impression wax. Casts were scanned using Activity102(®). Virtual models were compared to the scan of the typodont using Comparison(®). Differences were measured and descriptively analyzed. Estimated means with 95% confidence intervals were computed. Significance was assessed using linear mixed models. While pyramidal reference blocks had a mean difference of 0.019 mm (95% CI = 0.017-0.021 mm) to the master model, teeth without attachments showed 0.097 mm (95% CI = 0.082-0.111 mm), and teeth with brackets 0.169 mm (95% CI = 0.156-0.182 mm) (p < 0.001). Smallest mean was found when using protection wax only on the gingival bracket side (0.152 mm (95% CI = 0.113-0.192 mm)). Incisors deviated most (0.258 mm (95 % CI = 0.239-0.277 mm)). Teeth with brackets make impressions more inaccurate because of undercuts. Removing the archwire before taking the impression or covering the brackets on the gingival side shows tendencies toward better precision. Taking impressions during treatment with fixed appliances, some inaccuracy has to be taken into account.

  20. Effect of time and pH on physical-chemical properties of orthodontic brackets and wires.

    PubMed

    Dos Santos, Aretha Aliny Ramos; Pithon, Matheus Melo; Carlo, Fabíola Galbiatti Carvalho; Carlo, Hugo Lemes; de Lima, Bruno Alessandro Silva Guedes; Dos Passos, Tibério Andrade; Lacerda-Santos, Rogério

    2015-03-01

    To test the hypothesis that treatment time, debris/biofilm, and oral pH have an influence on the physical-chemical properties of orthodontic brackets and arch wires. One hundred twenty metal brackets were evaluated. They were divided into four groups (n  =  30) according to treatment time: group C (control) and groups T12, T24, and T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively). Rectangular stainless-steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology, composition of brackets, resistance to sliding of the bracket-wire set, surface roughness of wires, and oral pH were analyzed. One-way analysis of variance, followed by a Tukey multiple comparisons test, was used for statistical analysis (P < .05). Carbon and oxygen were shown to be elements that increased expressively and in direct proportion to time, and there was a progressive increase in the coefficient of friction and roughness of wires as a function of time of clinical use after 36 months. Oral pH showed a significant difference between group T36 and its control (P  =  .014). The hypothesis was partially accepted: treatment time and biofilm and debris accumulation in bracket slots were shown to have more influence on the degradation process and frictional force of these devices than did oral pH.

  1. A comparison of lower canine retraction and loss of anchorage between conventional and self-ligating brackets: a single-center randomized split-mouth controlled trial.

    PubMed

    da Costa Monini, André; Júnior, Luiz Gonzaga Gandini; Vianna, Alexandre Protásio; Martins, Renato Parsekian

    2017-05-01

    To evaluate the rate of lower canine retraction, anchorage loss, and changes on lower canines and first molars axial inclination using self-ligating and conventional brackets. Twenty-five adult patients with a treatment plan involving extractions of four first premolars were selected for this split-mouth trial and had either conventional or self-ligating brackets bonded to lower canines in a block randomization. Retraction was accomplished using 100-g nickel titanium closed-coil springs, which were reactivated each 4 weeks. Oblique radiographs were taken before and after total canine retraction and the cephalograms were superimposed on stable structures of the mandible. Cephalometric points were digitized twice by a single-blinded operator for error control and the average of the points were used to determine the following variables: canine cusp horizontal changes, molar cusp horizontal changes, and angulation changes in canines and molars. Paired t tests were used to analyze the blinded data for group differences. All patients reached final phase without bracket debonds. No differences were found between the two groups for all variables tested. No serious harm was observed. Both brackets showed the same rate of canine retraction and loss of anteroposterior anchorage of the molars. No changes were found between brackets regarding the inclination of canines and first molars. Using self-ligating brackets to retract lower canines will not increase the velocity of tooth movement, does not increase anchorage, and does not decrease tipping.

  2. Shear Bond Strength of Orthodontic Brackets to Tooth Enamel After Treatment With Different Tooth Bleaching Methods.

    PubMed

    Vahid Dastjerdi, Elahe; Khaloo, Negar; Mojahedi, Seyed Masoud; Azarsina, Mohadese

    2015-11-01

    Bleaching treatments decrease shear bond strength between orthodontic brackets and teeth; although definite results have not been reported in this regard. This study determined the effects of different bleaching protocols on the shear bond strength of orthodontic brackets to teeth. This experimental study was performed in Iran. Forty-eight extracted human premolars were randomly assigned into four groups. In the control group, no bleaching treatment was performed. In groups 2 - 4, the bleaching procedures were performed using carbamide peroxide 45%, carbamide peroxide 20% and diode laser, respectively. Two weeks later, brackets were bonded to teeth and thermocycled. The shear bond strengths of the brackets to the teeth were measured. Data was analyzed by one-way ANOVA and Dunnett post-hoc test. Shear bond strength of the brackets to the teeth were 10.54 ± 1.51, 6.37 ± 0.92, 7.67 ± 1.01 and 7.49 ± 1.19 MPa, in groups 1 - 4, respectively. Significant differences were found between control group and all other groups (P < 0.001); and also between groups 2 and 3 (P < 0.05). No significant differences were found between the other groups. The bleaching procedures using 20% carbamide peroxide and 45% carbamide peroxide and diode laser significantly decreased shear bond strength of brackets to the teeth. 45% carbamide peroxide had a more significant effect on bond strength compared to 20% carbamide peroxide. The difference in bond strength was not significant between laser group and either carbamide peroxide groups.

  3. Effect of Argon Laser on Enamel Demineralization around Orthodontic Brackets: An In Vitro Study

    PubMed Central

    Miresmaeili, Amirfarhang; Etrati Khosroshahi, Mohammad; Motahary, Pouya; Rezaei-Soufi, Loghman; Mahjub, Hossein; Dadashi, Maryam; Farhadian, Nasrin

    2014-01-01

    Objective This study was designed to evaluate the effect of argon laser irradiation on development and progress of enamel demineralization around orthodontic brackets. Materials and Methods: Fifty caries-free, intact human premolars were randomly assigned to one of the following five equal groups: Groups 1 (control) and 2: The brackets were bonded using conventional halogen light for 40s and argon laser for 10s, respectively. Teeth in group 3 were lased with argon laser for 10s before bracket bonding with halogen light. Group 4 was the same as group 3 except that brackets were also bonded with argon laser. In group 5 samples were bonded conventionally, immersed in an artificial caries solution for two days and then irradiated for 10s with argon laser. All samples were subjected to demineralization by artificial caries solution for 10 days. After bracket removal, samples were buccolingually sectioned and evaluated by polarized light microscopy. Decalcified lesion depth in each section was measured by a trained examiner in a blind fashion. Data were analyzed in SPSS 14 using one-way ANOVA and Tukey’s HSD post hoc test. Results: The control group showed the greatest mean lesion depth while group 5 revealed the lowest. The laser-treated groups had significantly lower mean lesion depth compared with the control group (P<0.05) except for group 4 (P=0.192). Conclusion: Argon laser irradiation for 10s before or during bracket bonding can increase caries resistance of intact and demineralized enamel. PMID:25584052

  4. Comparison of Shear Bond Strength of RMGI and Composite Resin for Orthodontic Bracket Bonding

    PubMed Central

    Yassaei, Soghra; Davari, Abdolrahim; Goldani Moghadam, Mahjobeh; Kamaei, Ahmad

    2014-01-01

    Objective: The aim of this study was to compare the shear bond strength (SBS) of resin modified glass ionomer (RMGI) and composite resin for bonding metal and ceramic brackets. Materials and Methods: Eighty-eight human premolars extracted for orthodontic purposes were divided into 4 groups (n=22). In groups 1 and 2, 22 metal and ceramic brackets were bonded using composite resin (Transbond XT), respectively. Twenty-two metal and ceramic brackets in groups 3 and 4, respectively were bonded using RMGI (Fuji Ortho LC, Japan). After photo polymerization, the teeth were stored in water and thermocycled (500 cycles between 5° and 55°). The SBS value of each sample was determined using a Universal Testing Machine. The amount of residual adhesive remaining on each tooth was evaluated under a stereomicroscope. Statistical analyses were done using two-way ANOVA. Results: RMGI bonded brackets had significantly lower SBS value compared to composite resin bonded groups. No statistically significant difference was observed between metal and ceramic brackets bonded with either the RMGI or composite resin. The comparison of the adhesive remnant index (ARI) scores between the groups indicated that the bracket failure mode was significantly different among groups (P<0.001) with more adhesive remaining on the teeth bonded with composite resin. Conclusion: RMGIs have significantly lower SBS compared to composite resin for orthodontic bonding purposes; however the provided SBS is still within the clinically acceptable range. PMID:25628663

  5. Comparison of shear bond strength of brackets recycled using micro sandblasting and industrial methods.

    PubMed

    Montero, Manuela M Haro; Vicente, Ascensión; Alfonso-Hernández, Noelia; Jiménez-López, Manuel; Bravo-González, Luis-Alberto

    2015-05-01

    To evaluate in vitro the shear bond strength of brackets recycled by sandblasting with aluminum oxide particles of different sizes or reconditioned industrially after successive rebonding. Eighty brackets were bonded and debonded sequentially three times. After the first debonding, brackets were divided into four groups: (group 1) sandblasting with aluminum oxide particles of 25 μ, (group 2) 50 μ, and (group 3) 110 μ, and (group 4) industrial recycling. Bond strength and adhesive material remaining on debonded bracket bases were evaluated for each successive debond. No significant differences were detected between the four groups following the first recycle (P > .05). After the second recycle, bond strength was significantly greater for the industrially recycled group than the other groups (P < .016). When shear bond strength was compared within each recycling method, the bond strength of sandblasted brackets decreased with the increase of particle size and with each recycle; for the industrially recycled group, no significant differences were detected between the three sequences (P > .016). In the evaluation of bond material remnant, the industrially recycled group left significantly less bond material after successive recycling than the other groups did (P < .016). Within each recycling method, the adhesive remnant decreased significantly after successive debond (P < .016). Industrial recycling obtained better results than sandblasting after three successive debondings. The brackets' shear bond strength decreased as the size of the aluminum oxide particle used for sandblasting increased and as recycling was repeated.

  6. Comparative assessment of different recycling methods of orthodontic brackets for clinical use.

    PubMed

    de Oliveira Correia, Ayla M; de Souza Matos, Felipe; Pilli Jóias, Renata; de Mello Rode, Sigmar; Cesar, Paulo F; Paranhos, Luiz R

    2017-06-01

    This study aimed to assess bond strength of the resin/bracket interface, under in-vitro shear stress, of metal brackets recycled by different clinical protocols. Sixty stainless steel orthodontic brackets were bonded on acrylic resin. The Transbond XT™ resin was applied at the base of the bracket aided by a matrix, obtaining 1 mm of thickness, and photoactivated with a LED device (40 s; 500 mW/cm2). Samples were randomly divided into four groups (N.=15) according to the reconditioning/recycling protocol: aluminum oxide (AO) 90 µm; hydrofluoric acid 60 s (HA60); hydrofluoric acid 120 s (HA120); hydrofluoric acid 60 s + silane (HA60S). After recycling, the resin was applied at the base of the bracket for shear testing in a universal testing machine (0.5 mm/min). After reconditioning/recycling, the surfaces were analyzed by Scanning Electron Microscopy. Data obtained after the shear test were subjected to ANOVA and Tukey's test (P<0.05). The AO group presented higher values of shear bond strength compared to the other reconditioning/recycling protocols (P<0.05). The HA120 and HA60S groups presented statistically similar results, but HA120 presented strength below the recommended limit. The recycling technique by aluminum oxide sandblasting was more effective for reconditioning orthodontic brackets when compared to the other protocols. The reconditioning technique with 10% hydrofluoric acid followed by the application of silane bonding agent may be used as an alternative protocol.

  7. Effects of fixed orthodontic treatment using conventional versus metal-injection molding brackets on salivary nickel and chromium levels: a double-blind randomized clinical trial.

    PubMed

    Amini, Fariborz; Harandi, Saghar; Mollaei, Mobina; Rakhshan, Vahid

    2015-10-01

    Despite the importance of nickel and chromium release from orthodontic brackets, there are no in vivo or in vitro studies on this issue in the case of metal-injection molding (MIM) brackets. Saliva samples were collected from 30 orthodontic patients divided randomly into two groups of conventional and MIM brackets, before treatment and 2 months later. Approved attendees with odd and even numbers were, respectively, assigned to the control and treatment groups. For blinding, the patients were not informed of their bracket types, and the saliva samples were coded. Nickel and chromium levels were determined using atomic absorption spectrophotometry. Data were analysed using repeated-measures two-way analysis of covariance, independent-samples t-test, chi-squared, Spearman and point-biserial correlation coefficients, Mann-Whitney, and Wilcoxon tests (α = 0.05). Mean nickel level increased from 7.87±8.14 (pre-treatment) to 12.57±9.96 (2nd month) in the control group, and from 8.62±9.85 (pre-treatment) to 8.86±6.42 µg/l in the MIM group. Both of these increases were significant (Wilcoxon P < 0.03). Average chromium level changed from 0.25±0.56 (pre-treatment) to 0.35±0.62 and from 0.42±0.48 to 0.26±0.57 µg/l in the MIM group. Only the reduction observed in the MIM group was significant (Wilcoxon P = 0.0438). Age and gender had no significant influence on ion levels (P > 0.1). The differences between both ions' levels measured in the 60th day in both bracket groups were not significant (Mann-Whitney P > 0.05). The extents of changes over time were not significantly different between the bracket types (Mann-Whitney P > 0.05). The sample size was not predetermined based on power calculations. The spectrophotometer was limited to detecting chromium concentrations above 0.25 µg/l. Ion discharge from brackets might continuously change. The current in vivo methods are unable to take such fluctuations into account. Nickel might increase in patients undergoing treatment with both bracket types, although the rate of increase might be greater in patients under treatment with conventional brackets. Using MIM brackets might reduce salivary chromium for a trivial but generalizable amount. Still, ion levels leached from conventional versus MIM brackets might not show a difference after 2 months. Age and gender might not affect the ion levels in normal people or orthodontic patients. The protocol is registered offline at the university library. The protocol was not published before the trail commencement. Self-funded (S. H.). None to declare. © The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Antimicrobial effect, frictional resistance, and surface roughness of stainless steel orthodontic brackets coated with nanofilms of silver and titanium oxide: a preliminary study.

    PubMed

    Ghasemi, Tania; Arash, Valiollah; Rabiee, Sayed Mahmood; Rajabnia, Ramazan; Pourzare, Amirhosein; Rakhshan, Vahid

    2017-06-01

    Nano-silver and nano-titanium oxide films can be coated over brackets in order to reduce bacterial aggregation and friction. However, their antimicrobial efficacy, surface roughness, and frictional resistance are not assessed before. Fifty-five stainless-steel brackets were divided into 5 groups of 11 brackets each: uncoated brackets, brackets coated with 60 µm silver, 100 µm silver, 60 µm titanium, and 100 µm titanium. Coating was performed using physical vapor deposition method. For friction test, three brackets from each group were randomly selected and tested. For scanning electron microscopy and atomic-force microscopy assessments, one and one brackets were selected from each group. For antibacterial assessment, six brackets were selected from each group. Of them, three were immediately subjected to direct contact with S. mutans. Colonies were counted 3, 6, 24, and 48 h of contact. The other three were stored in water for 3 months. Then were subjected to a similar direct contact test. Results pertaining to both subgroups were combined. Groups were compared statistically. Mean (SD) friction values of the groups 'control, silver-60, silver-100, titanium-60, and titanium-100' were 0.55 ± 0.14, 0.77 ± 0.08, 0.82 ± 0.11, 1.52 ± 0.24, and 1.57 ± 0.41 N, respectively (p = .0004, Kruskal-Wallis). Titanium frictions were significantly greater than control (p < .05), but silver groups were not (p > .05, Dunn). In the uncoated group, colony count increased exponentially within 48 h. The coated groups showed significant reductions in colony count (p < .05, two-way-repeated-measures ANOVA). In conclusions, all four explained coatings reduce surface roughness and bacterial growth. Nano-titanium films are not suitable for friction reduction. Nano-silver results were not conclusive and need future larger studies. © 2016 Wiley Periodicals, Inc.

  9. Shear bond strength of brackets on restorative materials: Comparison on various dental restorative materials using the universal primer Monobond® Plus.

    PubMed

    Ebert, Thomas; Elsner, Laura; Hirschfelder, Ursula; Hanke, Sebastian

    2016-03-01

    The purpose of this work was to analyze surfaces consisting of different restorative materials for shear bond strength (SBS) and failure patterns of metal and ceramic brackets. Bonding involved the use of a universal primer (Monobond® Plus, Ivoclar Vivadent). Six restorative materials were tested, including one composite resin (Clearfil Majesty™ Posterior, Kuraray Noritake Dental), one glass-ceramic material (IPS Empress® Esthetic, Ivoclar Vivadent), one oxide-ceramic material (CORiTEC Zr transpa Disc, imes-icore), two base-metal alloys (remanium® star, Dentaurum; Colado® CC, Ivoclar Vivadent), and one palladium-based alloy (Callisto® 75 Pd, Ivoclar Vivadent). Bovine incisors served as controls. Both metal and ceramic brackets (discovery®/discovery® pearl; Dentaurum) were bonded to the restorative surfaces after sandblasting and pretreatment with Monobond® Plus. A setup modified from DIN 13990-2 was used for SBS testing and adhesive remnant index (ARI)-based analysis of failure patterns. The metal brackets showed the highest mean SBS values on the glass-ceramic material (68.61 N/mm(2)) and the composite resin (67.58 N/mm(2)) and the lowest mean SBS on one of the base-metal alloys (Colado® CC; 14.01 N/mm(2)). The ceramic brackets showed the highest mean SBS on the glass-ceramic material (63.36 N/mm(2)) and the lowest mean SBS on the palladium-based alloy (38.48 N/mm(2)). Significant differences between the metal and ceramic brackets were observed in terms of both SBS values and ARI scores (p < 0.05). Under both bracket types, fractures of the composite-resin and the glass-ceramic samples were observed upon debonding. Opaque restorative materials under metal brackets were found to involve undercuring of the adhesive. Monobond® Plus succeeded in generating high bond strengths of both bracket types on all restorative surfaces. Given our observations of cohesive fracture (including cases of surface avulsion) of the composite-resin and the glass-ceramic samples, we recommend against using these material combinations in clinical practice.

  10. A Method for Writing Open-Ended Curved Arrow Notation Questions for Multiple-Choice Exams and Electronic-Response Systems

    ERIC Educational Resources Information Center

    Ruder, Suzanne M.; Straumanis, Andrei R.

    2009-01-01

    A critical stage in the process of developing a conceptual understanding of organic chemistry is learning to use curved arrow notation. From this stems the ability to predict reaction products and mechanisms beyond the realm of memorization. Since evaluation (i.e., testing) is known to be a key driver of student learning, it follows that a new…

  11. From Symbols to Movement: "LANTD", the Design and Implementation of a Laban Notation-Based Method for Teaching Dance

    ERIC Educational Resources Information Center

    Dania, Aspasia; Tyrovola, Vasiliki; Koutsouba, Maria

    2017-01-01

    The aim of this paper is to present the design and evaluate the impact of a Laban Notation-based method for Teaching Dance (LANTD) on novice dancers' performance, in the case of Greek traditional dance. In this research, traditional dance is conceived in its "second existence" as a kind of presentational activity performed outside its…

  12. Goal Structured Notation in a Radiation Hardening Safety Case for COTS-Based Spacecraft

    NASA Technical Reports Server (NTRS)

    Witulski, Arthur; Austin, Rebekah; Reed, Robert; Karsai, Gabor; Mahadevan, Nag; Sierawski, Brian; Evans, John; LaBel, Ken

    2016-01-01

    A systematic approach is presented to constructing a radiation assurance case using Goal Structured Notation (GSN) for spacecraft containing COTS parts. The GSN paradigm is applied to an SRAM single-event upset experiment board designed to fly on a CubeSat November 2016. Construction of a radiation assurance case without use of hardened parts or extensive radiation testing is discussed.

  13. M&S Journal. Volume 8, Issue 2, Summer 2013

    DTIC Science & Technology

    2013-01-01

    Modeling Notation ( BPMN ) [White and Miers, 2008], and the integration of the modeling notation with executable simulation engines [Anupindi 2005...activities and the supporting IT in BPMN and use that to compute MOE for a mission instance. Requirements for Modeling Missions To understand the...representation versus impact computation tradeoffs we selected BPMN , along with some proposed extensions to represent information dependencies, as the

  14. A Basic Guide to UNIX.

    DTIC Science & Technology

    1985-10-01

    Stevie Wonder "] @begin[address] Mr. Stevie Wonder 111 Super Street...enthusiastic president for your Stevie Wonder Fan Club, you know you can call on me. @end[body] Yours forever, Ms. Fan Ardent @begin[notations] FA/fa cc: @tMr...Peter Allen @\\Ms. Aretha Franklin Enc. "A Groupie’s View of Stevie Wonder " @end[notations] -7 55 October 31, 1981 Mr. Stevie Wonder 111

  15. Sampling probability distributions of lesions in mammograms

    NASA Astrophysics Data System (ADS)

    Looney, P.; Warren, L. M.; Dance, D. R.; Young, K. C.

    2015-03-01

    One approach to image perception studies in mammography using virtual clinical trials involves the insertion of simulated lesions into normal mammograms. To facilitate this, a method has been developed that allows for sampling of lesion positions across the cranio-caudal and medio-lateral radiographic projections in accordance with measured distributions of real lesion locations. 6825 mammograms from our mammography image database were segmented to find the breast outline. The outlines were averaged and smoothed to produce an average outline for each laterality and radiographic projection. Lesions in 3304 mammograms with malignant findings were mapped on to a standardised breast image corresponding to the average breast outline using piecewise affine transforms. A four dimensional probability distribution function was found from the lesion locations in the cranio-caudal and medio-lateral radiographic projections for calcification and noncalcification lesions. Lesion locations sampled from this probability distribution function were mapped on to individual mammograms using a piecewise affine transform which transforms the average outline to the outline of the breast in the mammogram. The four dimensional probability distribution function was validated by comparing it to the two dimensional distributions found by considering each radiographic projection and laterality independently. The correlation of the location of the lesions sampled from the four dimensional probability distribution function across radiographic projections was shown to match the correlation of the locations of the original mapped lesion locations. The current system has been implemented as a web-service on a server using the Python Django framework. The server performs the sampling, performs the mapping and returns the results in a javascript object notation format.

  16. Optimization of Compressor Mounting Bracket of a Passenger Car

    NASA Astrophysics Data System (ADS)

    Kalsi, Sachin; Singh, Daljeet; Saini, J. S.

    2018-05-01

    In the present work, the CAE tools are used for the optimization of the compressor mounting bracket used in an automobile. Both static and dynamic analysis is done for the bracket. With the objective to minimize the mass and increase the stiffness of the bracket, the new design is optimized using shape and topology optimization techniques. The optimized design given by CAE tool is then validated experimentally. The new design results in lower level of vibrations, contribute to lower mass along with lesser cost which is effective in air conditioning system as well as the efficiency of a vehicle. The results given by CAE tool had a very good correlation with the experimental results.

  17. Semantically-Rigorous Systems Engineering Modeling Using Sysml and OWL

    NASA Technical Reports Server (NTRS)

    Jenkins, J. Steven; Rouquette, Nicolas F.

    2012-01-01

    The Systems Modeling Language (SysML) has found wide acceptance as a standard graphical notation for the domain of systems engineering. SysML subsets and extends the Unified Modeling Language (UML) to define conventions for expressing structural, behavioral, and analytical elements, and relationships among them. SysML-enabled modeling tools are available from multiple providers, and have been used for diverse projects in military aerospace, scientific exploration, and civil engineering. The Web Ontology Language (OWL) has found wide acceptance as a standard notation for knowledge representation. OWL-enabled modeling tools are available from multiple providers, as well as auxiliary assets such as reasoners and application programming interface libraries, etc. OWL has been applied to diverse projects in a wide array of fields. While the emphasis in SysML is on notation, SysML inherits (from UML) a semantic foundation that provides for limited reasoning and analysis. UML's partial formalization (FUML), however, does not cover the full semantics of SysML, which is a substantial impediment to developing high confidence in the soundness of any conclusions drawn therefrom. OWL, by contrast, was developed from the beginning on formal logical principles, and consequently provides strong support for verification of consistency and satisfiability, extraction of entailments, conjunctive query answering, etc. This emphasis on formal logic is counterbalanced by the absence of any graphical notation conventions in the OWL standards. Consequently, OWL has had only limited adoption in systems engineering. The complementary strengths and weaknesses of SysML and OWL motivate an interest in combining them in such a way that we can benefit from the attractive graphical notation of SysML and the formal reasoning of OWL. This paper describes an approach to achieving that combination.

  18. A Web-based Tool to Aid the Identification of Chemicals Potentially Posing a Health Risk through Percutaneous Exposure.

    PubMed

    Gorman Ng, Melanie; Milon, Antoine; Vernez, David; Lavoué, Jérôme

    2016-04-01

    Occupational hygiene practitioners typically assess the risk posed by occupational exposure by comparing exposure measurements to regulatory occupational exposure limits (OELs). In most jurisdictions, OELs are only available for exposure by the inhalation pathway. Skin notations are used to indicate substances for which dermal exposure may lead to health effects. However, these notations are either present or absent and provide no indication of acceptable levels of exposure. Furthermore, the methodology and framework for assigning skin notation differ widely across jurisdictions resulting in inconsistencies in the substances that carry notations. The UPERCUT tool was developed in response to these limitations. It helps occupational health stakeholders to assess the hazard associated with dermal exposure to chemicals. UPERCUT integrates dermal quantitative structure-activity relationships (QSARs) and toxicological data to provide users with a skin hazard index called the dermal hazard ratio (DHR) for the substance and scenario of interest. The DHR is the ratio between the estimated 'received' dose and the 'acceptable' dose. The 'received' dose is estimated using physico-chemical data and information on the exposure scenario provided by the user (body parts exposure and exposure duration), and the 'acceptable' dose is estimated using inhalation OELs and toxicological data. The uncertainty surrounding the DHR is estimated with Monte Carlo simulation. Additional information on the selected substances includes intrinsic skin permeation potential of the substance and the existence of skin notations. UPERCUT is the only available tool that estimates the absorbed dose and compares this to an acceptable dose. In the absence of dermal OELs it provides a systematic and simple approach for screening dermal exposure scenarios for 1686 substances. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  19. Comparison of athlete-coach perceptions of internal and external load markers for elite junior tennis training.

    PubMed

    Murphy, Alistair P; Duffield, Rob; Kellett, Aaron; Reid, Machar

    2014-09-01

    To investigate the discrepancy between coach and athlete perceptions of internal load and notational analysis of external load in elite junior tennis. Fourteen elite junior tennis players and 6 international coaches were recruited. Ratings of perceived exertion (RPEs) were recorded for individual drills and whole sessions, along with a rating of mental exertion, coach rating of intended session exertion, and athlete heart rate (HR). Furthermore, total stroke count and unforced-error count were notated using video coding after each session, alongside coach and athlete estimations of shots and errors made. Finally, regression analyses explained the variance in the criterion variables of athlete and coach RPE. Repeated-measures analyses of variance and interclass correlation coefficients revealed that coaches significantly (P < .01) underestimated athlete session RPE, with only moderate correlation (r = .59) demonstrated between coach and athlete. However, athlete drill RPE (P = .14; r = .71) and mental exertion (P = .44; r = .68) were comparable and substantially correlated. No significant differences in estimated stroke count were evident between athlete and coach (P = .21), athlete notational analysis (P = .06), or coach notational analysis (P = .49). Coaches estimated significantly greater unforced errors than either athletes or notational analysis (P < .01). Regression analyses found that 54.5% of variance in coach RPE was explained by intended session exertion and coach drill RPE, while drill RPE and peak HR explained 45.3% of the variance in athlete session RPE. Coaches misinterpreted session RPE but not drill RPE, while inaccurately monitoring error counts. Improved understanding of external- and internal-load monitoring may help coach-athlete relationships in individual sports like tennis avoid maladaptive training.

  20. Faddeev–Jackiw quantization of an Abelian and non-Abelian exotic action for gravity in three dimensions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Escalante, Alberto, E-mail: aescalan@ifuap.buap.mx; Manuel-Cabrera, J., E-mail: jmanuel@ifuap.buap.mx

    2015-10-15

    A detailed Faddeev–Jackiw quantization of an Abelian and non-Abelian exotic action for gravity in three dimensions is performed. We obtain for the theories under study the constraints, the gauge transformations, the generalized Faddeev–Jackiw brackets and we perform the counting of physical degrees of freedom. In addition, we compare our results with those found in the literature where the canonical analysis is developed, in particular, we show that both the generalized Faddeev–Jackiw brackets and Dirac’s brackets coincide to each other. Finally we discuss some remarks and prospects. - Highlights: • A detailed Faddeev–Jackiw analysis for exotic action of gravity is performed.more » • We show that Dirac’s brackets and Generalized [FJ] brackets are equivalent. • Without fixing the gauge exotic action is a non-commutative theory. • The fundamental gauge transformations of the theory are found. • Dirac and Faddeev–Jackiw approaches are compared.« less

Top