Tack Measurements of Prepreg Tape at Variable Temperature and Humidity
NASA Technical Reports Server (NTRS)
Wohl, Christopher; Palmieri, Frank L.; Forghani, Alireza; Hickmott, Curtis; Bedayat, Houman; Coxon, Brian; Poursartip, Anoush; Grimsley, Brian
2017-01-01
NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly strong dependence on temperature and humidity. Although an increase in either of these parameters reduces tack strength, a maximum in tack was predicted to occur under conditions of low temperature and moderate humidity.
Michaelis, Marc; Leopold, Claudia S
2015-12-30
The tack of a pressure sensitive adhesive (PSA) is not an inherent material property and strongly depends on the measurement conditions. Following the concept of a measurement system analysis (MSA), influencing factors of the probe tack test were investigated by a design of experiments (DoE) approach. A response surface design with 38 runs was built to evaluate the influence of detachment speed, dwell time, contact force, adhesive film thickness and API content on tack, determined as the maximum of the stress strain curve (σmax). It could be shown that all investigated factors have a significant effect on the response and that the DoE approach allowed to detect two-factorial interactions between the dwell time, the contact force, the adhesive film thickness and the API content. Surprisingly, it was found that tack increases with decreasing and not with increasing adhesive film thickness. Copyright © 2015. Published by Elsevier B.V.
Mechanisms of Probe Tack Adhesion of Model Acrylic Elastomers
NASA Astrophysics Data System (ADS)
Lakrout, Hamed; Creton, Costantino; Ahn, Dongchan; Shull, Kenneth R.
1997-03-01
The adhesion mechanisms of model acrylate homopolymers and copolymers are studied with an instrumented probe tack test. A video camera positioned under the transparent glass substrate records the bonding and debonding process while the force displacement curve is acquired. This setup allows to couple the observation of the cavitation and fibrillation mechanisms, occurring during the debonding of the film from the stainless steel probe, with the mechanical measurement of stress and strain. The transitions between different debonding mechanisms are critically dicussed in terms of the bulk and surface properties of the adhesive and its molecular structure.
Lerdsirisopon, Sopon; Frisella, Margaret M; Matthews, Brent D; Deeken, Corey R
2011-12-01
This study aimed to determine whether the strength and extensibility of hernia repair materials are negatively influenced by the application of helical titanium tacks. This study evaluated 14 meshes including bare polypropylene, macroporous polytetrafluoroethylene, absorbable barrier, partially absorbable mesh, and expanded polytetrafluoroethylene materials. Each mesh provided 15 specimens, which were prepared in 7.5 × 7.5-cm squares. Of these, 5 "undamaged" specimens were subjected to ball-burst testing to determine their biomechanical properties before application of helical titanium tacks (ProTack). To 10 "damaged" specimens 7 tacks were applied 1 cm apart in a 3.5-cm-diameter circle using a tacking force of 25 to 28 N. The tacks were removed from five of the specimens before ball-burst testing and left intact in the remaining five specimens. The application of tacks had no effect on the tensile strength of Dualmesh, ProLite Ultra, Infinit, Ultrapro, C-QUR Lite (<6 in.), Prolene Soft, or Physiomesh, but the tensile strengths were reduced for Bard Mesh, C-QUR, ProLite, and C-QUR Lite (>6 in.). Most of the meshes did not exhibit significantly different tensile strengths between removal of tacks and tacks left intact. Exceptions included C-QUR, Prolene, Ultrapro, and Bard Soft Mesh, which were weaker with removal of tacks than with tacks left intact during the test. Damage due to the application of helical titanium tacks also caused increased strain at a stress of 16 N/cm for all the meshes except C-QUR Lite (>6 in.) and Physiomesh. Many of the meshes evaluated in this study exhibited damage in the form of reduced tensile strength and increased extensibility after the application of tacks compared with the corresponding "undamaged" meshes. Meshes with smaller interstices and larger filaments were influenced negatively by the application of helical titanium tacks, whereas mesh designs with larger interstices and smaller filaments tended to maintain their baseline mechanical properties.
Discerning autotrophy, mixotrophy and heterotrophy in marine TACK archaea from the North Atlantic.
Seyler, Lauren M; McGuinness, Lora R; Gilbert, Jack A; Biddle, Jennifer F; Gong, Donglai; Kerkhof, Lee J
2018-03-01
DNA stable isotope probing (SIP) was used to track the uptake of organic and inorganic carbon sources for TACK archaea (Thaumarchaeota/Aigarchaeota/Crenarchaeota/Korarchaeota) on a cruise of opportunity in the North Atlantic. Due to water limitations, duplicate samples from the deep photic (60-115 m), the mesopelagic zones (local oxygen minimum; 215-835 m) and the bathypelagic zone (2085-2835 m) were amended with various combinations of 12C- or 13C-acetate/urea/bicarbonate to assess cellular carbon acquisition. The SIP results indicated the majority of TACK archaeal operational taxonomic units (OTUs) incorporated 13C from acetate and/or urea into newly synthesized DNA within 48 h. A small fraction (16%) of the OTUs, often representing the most dominant members of the archaeal community, were able to incorporate bicarbonate in addition to organic substrates. Only two TACK archaeal OTUs were found to incorporate bicarbonate but not urea or acetate. These results further demonstrate the utility of SIP to elucidate the metabolic capability of mesothermal archaea in distinct oceanic settings and suggest that TACK archaea play a role in organic carbon recycling in the mid-depth to deep ocean.
Performance evaluation and specification of trackless tack : [project summary].
DOT National Transportation Integrated Search
2016-09-01
Researchers compared two tracking resistance tests for tack: a track-free time test and a modified dynamic shear rheometer (DSR) tackiness test. : Researchers compared four bond strength tests: interface shear, pull-off, torque, and Arcan. Then, usin...
Effects of Fusion Tack Welds on Self-Reacting Friction Stir Welds
NASA Technical Reports Server (NTRS)
Nunes, A. C., Jr.; Pendleton, M. L.; Brooke, S. A.; Russell, C. K.
2012-01-01
In order to know whether fusion tack welds would affect the strength of self-reacting friction stir seam welds in 2195-T87 aluminum alloy, the fracture stresses of 144 tensile test coupons cut from 24 welded panels containing segments of friction stir welds were measured. Each of the panels was welded under unique processing conditions. A measure of the effect of the tack welds for each panel was devised. An analysis of the measures of the tack weld effect supported the hypothesis that fusion tack welds do not affect the strength of self-reacting friction stir welds to a 5% level of confidence.
PMR polyimide prepreg with improved tack characteristics
NASA Technical Reports Server (NTRS)
Serafini, T. T.; Delvigs, P.
1976-01-01
Current PMR Polyimide prepreg technology utilizes methanol or ethanol solvents for preparation of the PMR prepreg solutions. The volatility of these solvents limits the tack and drape retention characteristics of unprotected prepreg exposed to ambient conditions. Studies conducted to achieve PMR 15 Polyimide prepreg with improved tack and drape characteristics were described. Improved tack and drape retention were obtained by incorporation of an additional monomer. The effects of various levels of the added monomer on the thermo-oxidative stability and mechanical properties of graphite fiber reinforced PMR 15 composites exposed and tested at 316 C (600 F) were discussed.
Properties of autoclaved Gr/PI composites made from improved tack PMR-15 prepreg
NASA Technical Reports Server (NTRS)
Vannucci, R. D.
1985-01-01
Autoclave processing studies were conducted, using improved tack PMR-15 prepreg, to determine the effect of tack enhancing PMR resin modifications on composite processability and mechanical properties. Improved tack graphite fiber reinforced PMR-15 prepregs were prepared and exposed to ambient conditions for various times and then autoclave molded into composites. Composite specimens were prepared and tested for flexural and interlaminar shear strengths at room temperature and 316 C. The retention of flexural and interlaminar shear strength as a function of exposure in air at 316 C was also determined. The results show that the modified PMR resin solutions provide prepreg with improved tack and drape retention characteristics without adversely affecting processability or mechanical properties of autoclave molded graphite fiber reinforced PMR-15 composites.
NASA Technical Reports Server (NTRS)
Serafini, T. T.; Delvigs, P.
1978-01-01
Current PMR Polyimide prepreg technology utilizes methanol or ethanol solvents for preparation of the PMR prepreg solutions. The volatility of these solvents limits the tack and drape retention characteristics of unprotected prepreg exposed to ambient conditions. Studies conducted to achieve PMR 15 Polyimide prepreg with improved tack and drape characteristics are described. Improved tack and drape retention were obtained by incorporation of an additional monomer. The effects of various levels of the added monomer on the thermo-oxidative stability and mechanical properties of graphite fiber reinforced PMR 15 composites exposed and tested at 316 C (600 F) are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahn, K.J.; Seferis, J.C.; Pelton, T.
A compression to tension apparatus and a methodology capable of measuring prepreg tack have been analyzed in detail in order to establish fundamental material and operating characteristics. Both intrinsic and extrinsic parameters influencing prepreg tack were identified and analyzed using commercially available carbon fiber/epoxy prepregs and mechanical testing equipment. Two different factors, (1) contact (or wetting) area of adjacent prepreg plies and (2) viscoelastic properties of the prepreg, were found to control prepreg tack. At low temperatures, contact area was the main deformation controlling step, while at high temperatures, the viscoelastic property of the prepreg was found to be dominant.more » Both interlaminar and intralaminar deformations were observed depending on the prepreg systems examined as well as the operating conditions of the test. In addition, hold time, hold pressure, loading rate, resin content, and out-time were also found to affect prepreg tack. Energy of separation, which may be viewed as a descriptor of prepreg tack, was observed to increase with increasing hold time, hold pressure, and loading rate. Energy of separation also showed a maximum value at a specific resin content for a specific prepreg system, while it decreased with increasing prepreg out-time due to prepreg surface characteristic change rather than bulk physical aging. Conclusively, it was observed that prepreg tack must be viewed as an extrinsic, bulk, but surface-sensitive, viscoelastic property which depends on material as well as operating conditions.« less
Tack Coat Performance and Materials Study
DOT National Transportation Integrated Search
2017-06-01
A good bond provided by a tack coat can improve performance of asphalt overlays. The objectives of this research were: (1) develop a method for testing the bond between pavement layers; (2) evaluate the bond performance and predict long-term performa...
Tack coat optimization for HMA overlays : accelerated pavement test report.
DOT National Transportation Integrated Search
2009-02-01
Interface bonding between hot-mix asphalt (HMA) overlays and Portland cement concrete (PCC) pavements is one : of the most significant factors affecting overlay service life. This study was performed to quantify the effects of HMA type, : tack coat t...
PMR-15 polyimide modifications for improved prepreg tack
NASA Technical Reports Server (NTRS)
Vannucci, R. D.
1982-01-01
The use of mixed solvents and of modified monomeric ester reactants was investigated as a means of improving the tack and drape retention characteristics of PMR-15 polyimide prepreg. Methanol, ethanol, 1-propanol and 1-butanol were used to prepare the esters, prepreg solutions, and T-300 graphite fabric and Celion 6000 unidirectional fiber prepregs. The tack retention characteristics of the T-300 fabric prepreg after exposure to simulated use conditions were determined using a simple lap shear test. Drape was qualitatively assessed by visually monitoring the deformability of the prepreg. Thermo-oxidative stability and mechanical properties retention of the Celion 6000 grahite fiber composites were determined as a function of exposure time in air at 600 F.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brasser, R.; Ida, S.; Matsumura, S.
2016-04-20
The Grand Tack model of terrestrial planet formation has emerged in recent years as the premier scenario used to account for several observed features of the inner solar system. It relies on the early migration of the giant planets to gravitationally sculpt and mix the planetesimal disk down to ∼1 au, after which the terrestrial planets accrete from material remaining in a narrow circumsolar annulus. Here, we investigate how the model fares under a range of initial conditions and migration course-change (“tack”) locations. We run a large number of N-body simulations with tack locations of 1.5 and 2 au andmore » test initial conditions using equal-mass planetary embryos and a semi-analytical approach to oligarchic growth. We make use of a recent model of the protosolar disk that takes into account viscous heating, includes the full effect of type 1 migration, and employs a realistic mass–radius relation for the growing terrestrial planets. Our results show that the canonical tack location of Jupiter at 1.5 au is inconsistent with the most massive planet residing at 1 au at greater than 95% confidence. This favors a tack farther out at 2 au for the disk model and parameters employed. Of the different initial conditions, we find that the oligarchic case is capable of statistically reproducing the orbital architecture and mass distribution of the terrestrial planets, while the equal-mass embryo case is not.« less
Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich
2011-01-01
Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Tool For Friction Stir Tack Welding of Aluminum Alloys
NASA Technical Reports Server (NTRS)
Bjorkman, Gerald W.; Dingler, Johnny W.; Loftus, Zachary
2003-01-01
A small friction-stir-welding tool has been developed for use in tack welding of aluminum-alloy workpieces. It is necessary to tack-weld the workpieces in order to hold them together during friction stir welding because (1) in operation, a full-size friction-stir-welding tool exerts a large force that tends to separate the workpieces and (2) clamping the workpieces is not sufficient to resist this force. It is possible to tack the pieces together by gas tungsten arc welding, but the process can be awkward and time-consuming and can cause sufficient damage to necessitate rework. Friction stir tack welding does not entail these disadvantages. In addition, friction stir tack welding can be accomplished by use of the same automated equipment (except for the welding tool) used in subsequent full friction stir welding. The tool for friction stir tack welding resembles the tool for full friction stir welding, but has a narrower shoulder and a shorter pin. The shorter pin generates a smaller workpiece-separating force so that clamping suffices to keep the workpieces together. This tool produces a continuous or intermittent partial-penetration tack weld. The tack weld is subsequently consumed by action of the larger tool used in full friction stir welding tool.
Kriangkrai, Worawut; Puttipipatkhachorn, Satit; Sriamornsak, Pornsak; Pongjanyakul, Thaned; Sungthongjeen, Srisagul
2014-12-01
Tackiness caused by the gas-entrapped membrane (Eudragit(®)RL 30D) was usually observed during storage of the effervescent floating tablets, leading to failure in floatation and sustained release. In this work, common anti-tacking agents (glyceryl monostearate (GMS) and talc) were used to solve this tackiness problem. The impact of anti-tacking agent on the properties of free films and corresponding floating tablets was investigated. GMS was more effective than talc in reducing tackiness of the film. Addition and increasing amount of anti-tacking agents lowered the film mechanical strength, but the coating films were still strong and flexible enough to resist the generated gas pressure inside the floating tablet. Wettability and water vapor permeability of the film decreased with increasing level of anti-tacking agents as a result of their hydrophobicity. No interaction between anti-tacking agents and polymer was observed as confirmed by Fourier transform infrared spectroscopy, powder X-ray diffractometry, and differential scanning calorimetry studies. Increasing amount of anti-tacking agents decreased time to float and tended to retard drug release of the floating tablets. Floating properties and drug release were also influenced by type of anti-tacking agents. The obtained floating tablets still possessed good floating properties and controlled drug release even though anti-tacking agent had some effects. The results demonstrated that the tackiness problem of the floating tablets could be solved by incorporating anti-tacking agent into the gas-entrapped membrane.
Non-ferromagnetic retinal tacks are a tolerable risk in magnetic resonance imaging.
Kuethe, D O; Small, K W; Blinder, R A
1991-01-01
Should patients with cobalt alloy (ASTM F563) retinal tacks (Grieshaber cat. #611.95) in their eyes be subjected to the magnetic fields used in magnetic resonance imaging? Although the tacks are not ferromagnetic, they will experience a retarding torque when they are moved at the high angular velocities of human eye motion. Because retinal tacks are small (2.85 mm x 0.9 mm), the torque is difficult to measure. Rather, we measured the torque on a model 25.4 times larger and used a scaling law derived from Maxwell's equations to calculate the force on the tack. The scaling law states that the torque varies with the cube of the object's length. To mimic the motion, models of retinal tacks were attached to Plexiglas rods and the assemblies were swung as pendulums. The pendulums were oriented in the magnetic field of a 1.5 T imager to experience the greatest retardation. Retarding torques were estimated from the rate of decrease of the pendulum amplitude, both inside and outside the magnet. Even if the retinal tacks were as conductive as 6061T6 aluminum alloy (25 MS/m) and the velocity of the surface of the eye were 24 cm/s (angular vel. of 1130 deg/s), the retarding torque would be only 1.6 times the weight of the tack acting with a lever arm as long as the distance from its tip to its center of gravity. The maximum retarding torque on an implanted retinal tack in a 1.5 T magnet is similar to the torque produced by gravity alone acting on the tack and is a tolerable risk.(ABSTRACT TRUNCATED AT 250 WORDS)
Suture versus tack fixation of mesh in laparoscopic umbilical hernia repair.
Kitamura, Riley K; Choi, Jacqueline; Lynn, Elizabeth; Divino, Celia M
2013-01-01
Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation. Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction. Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups. There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.
Field tack coat evaluator (ATACKer)
DOT National Transportation Integrated Search
2004-12-15
Asphalt tack coats are applied during pavement construction to ensure bond between pavement layers, thus providing a more durable pavement. A prototype tack coat evaluation device (TCED) was developed to evaluate the tensile and torque-shear strength...
Field tack coat evaluator (ATACKer).
DOT National Transportation Integrated Search
2004-12-14
Asphalt tack coats are applied during pavement construction to ensure bond between pavement layers, thus providing : a more durable pavement. A prototype tack coat evaluation device (TCED) was developed to evaluate the tensile and : torque-shear stre...
Broken or dislodged poly-L-lactic acid bioabsorbable tacks in patients after SLAP lesion surgery.
Sassmannshausen, Greg; Sukay, Michael; Mair, Scott D
2006-06-01
To document the complication of bioabsorbable poly-L-lactic acid (PLLA) tack breakage and repair failure after arthroscopic stabilization of SLAP lesions. Six patients (average age, 38 years) were referred to the senior author because of persistent postoperative pain and disability after arthroscopic stabilization of an unstable SLAP lesion was performed with bioabsorbable PLLA tacks. A total of eight tacks were used in the six patients, and the time from index procedure to evaluation at our facility averaged 9.5 months (range, 8 to 12 months). Three patients experienced an identifiable reinjury an average of 4 months after the index procedure was performed. Magnetic resonance imaging (MRI) revealed a broken or dislodged tack in all cases. All patients were taken to the operating room for arthroscopic evaluation of the biceps anchor, tack fragment removal, and restabilization of the SLAP lesion as needed. At repeat arthroscopy, all shoulders were found to have minimal healing of the SLAP lesion with failure of the bioabsorbable tack. Chondral injury was noted in 2 cases. In all cases, revision SLAP repair was performed with the use of arthroscopic suture repair. At an average follow-up of 14 months (range, 8 to 17 months), all patients reported alleviation of symptoms. Five patients had returned to work with no or minimal symptoms. One patient experienced significant improvement in function and range of motion but did not return to work. Bioabsorbable PLLA tack breakage or dislodgement is a potential postoperative complication after SLAP lesions are arthroscopically stabilized. This event may result in postoperative reports of pain or mechanical symptoms. Surgeons who use these devices must be aware of the potential complications when they evaluate postoperative patients with persistent complaints. MRI may be helpful in identifying tack fragments. Subsequent arthroscopy to evaluate biceps anchor healing, remove tack fragments, and restabilize the labral lesion may be indicated. Level IV, case series.
Fracture toughness in Mode I (GIC) for ductile adhesives
NASA Astrophysics Data System (ADS)
Gálvez, P.; Carbas, RJC; Campilho, RDSG; Abenojar, J.; Martínez, MA; Silva LFM, da
2017-05-01
Works carried out in this publication belong to a project that seeks the replacement of welded joints by adhesive joints at stress concentration nodes in bus structures. Fracture toughness in Mode I (GIC) has been measured for two different ductile adhesives, SikaTack Drive and SikaForce 7720. SikaTack Drive is a single-component polyurethane adhesive with high viscoelasticity (more than 100%), whose main use is the car-glass joining and SikaForce 7720 is double-component structural polyurethane adhesive. Experimental works have been carried out from the test called Double Cantilever Beam (DCB), using two steel beams as adherents and an adhesive thickness according to the problem posed in the Project, of 2 and 3 mm for SikaForce 7720 and SikaTack Drive, respectively. Three different methods have been used for measuring the fracture toughness in mode I (GIC) from the values obtained in the experimental DCB procedure for each adhesive: Corrected Beam Theory (CBT), Compliance Calibration Method (CCM) and Compliance Based Beam Method (CBBM). Four DCB specimens have been tested for each adhesive. Dispersion of each GIC calculation method for each adhesive has been studied. Likewise variations between the three different methods have been also studied for each adhesive.
Kohta, M; Iwasaki, T
2015-01-01
In the treatment of pressure ulcers and leg ulcers it is necessary to achieve an effective balance between adhesive and skin-protective properties. We speculated that addition of a tackifying agent (TA) to ceramide 2-containing hydrocolloid dressings would increase their adhesiveness under dry conditions and reduce their adhesiveness under wet conditions because dry tack converts to wet tack after water absorption. We prepared ceramide 2-containing hydrocolloid dressings with varying amounts of TA. Basic characteristics of the test ceraminde dressings, such as initial tack force and peeling force, were evaluated using standard methods. Peeling force and stratum corneum (SC) removal on healthy human skin were also evaluated at 20 minutes, 7 hours, and 72 hours. In addition, the effect of 10 repeated applications on transepidermal water loss (TEWL) was investigated on the skin of hairless mice under dry and wet conditions. Statistical analyses were performed using one-way analysis of variance followed by Dunnett's multiple comparison test. A p-value of <0.05 was considered statistically significant. On a stainless steel substrate, initial tack force and 180° peeling force increased as TA content increased. Twenty minutes after application on human skin, peeling force and SC removal increased with increasing TA content. When TA contents were over 10%, significant differences in peeling force and SC removal were obtained compared with ceramide 2-containing hydrocolloid dressings without TA (p<0.05). However, a TA content-dependent increase in peeling force was not evident 7 hours and 72 hours after application. Under dry conditions, TEWL increased with repeated application and peeling. Conversely, no significant increases in TEWL were evident under wet conditions after 10 repeated applications and peelings. Our data demonstrate that the initial attachment of ceramide 2-containing hydrocolloid dressings to the skin increases with addition of TA. Skin damage can be avoided by conversion of the adhesive system to wet tack with water absorption. Masushi Kohta and Tetsuji IwasakI are employees of ALCARE Co., Ltd., Japan. This project was supported by an unrestricted grant from ALCARE.
Physiological characteristics of America's Cup sailors.
Bernardi, Marco; Quattrini, Filippo M; Rodio, Angelo; Fontana, Giuseppe; Madaffari, Andrea; Brugnoli, Marco; Marchetti, Marco
2007-08-01
The aim of this study was to assess the physiological profile of America's Cup grinders and mastmen, by measuring energy expenditure during sailing and assessing their aerobic and anaerobic fitness. The study focused on estimating the energy used during grinding activity, by measuring oxygen uptake (VO(2)) during sail setting in real sailing conditions. In the laboratory, using an arm-cranking ergometer, we measured VO(2peak) during an incremental maximal exercise test and total energy expended during the effort and recovery phases of an all-out test that simulated grinding activity, in six grinders and mastmen and ten sailors of the same crew. Total energy used during grinding corresponded to 45% (s = 9) and 51% (s = 5) of that used in the all-out test (234 kJ, s = 21.7) for tacks and gybes, respectively. In both grinding activity and the all-out test, VO(2) increased during and after the effort. The "VO(2) top value" was 53% (s = 8.6), 68% (s = 5.5), and 78% (s = 3.1) of VO(2peak) (4.7 l . min(-1), s = 0.43) in tacks, gybes, and the all-out test, respectively. During fast sequences of grinding activity, the "VO(2) top value" reached 65% (s = 7.1) VO(2peak) in tacks and 91% (s = 3.3) VO(2peak) in gybes. Our results suggest that grinders and mastmen are characterized by a high anaerobic capacity but their performance can be improved by powering aerobic fitness, to increase this energy contribution to all-out efforts and to guarantee fast recovery when grinding activity is repeated with short rest intervals.
Bosiers, Marc; Scheinert, Dierk; Hendriks, Jeroen M H; Wissgott, Christian; Peeters, Patrick; Zeller, Thomas; Brodmann, Marianne; Staffa, Robert
2016-07-01
The mechanism of angioplasty is disruption of atherosclerotic plaque, which often results in dissections. Dissection after percutaneous transluminal angioplasty (PTA) remains a significant clinical problem and untreated may cause acute occlusion or later restenosis. Stents are used to manage dissections, which is often followed by in-stent restenosis and occasionally stent fracture. Tack (Intact Vascular, Wayne, Pa) implants have minimal metal and low radial force and are specifically designed for dissection repair. This study evaluated Tack implants for treatment of dissections resulting from standard balloon PTA for femoral-popliteal arterial disease. Twelve-month outcomes after Tack treatment of post-PTA dissections are described. This prospective, single-arm study evaluated patients with ischemia (Rutherford clinical category 2-4) caused by lesions of the superficial femoral and popliteal arteries. Patients were treated with standard balloon angioplasty, and post-PTA dissections were treated with Tacks. The primary end points were core laboratory-adjudicated device technical success, defined as the ability of the Tack implants to resolve post-PTA dissection, and device safety, defined as the absence of new-onset major adverse events. Patients were followed up to 12 months after implantation. Tacks were used in 130 patients with post-PTA dissections (74.0% ≥ grade C). Technical success was achieved in 128 (98.5%) patients with no major adverse events at 30 days. The 12-month patency was 76.4%, and freedom from target lesion revascularization was 89.5%. Significant improvement from baseline was observed in Rutherford clinical category (82.8% with grade ≤1) and ankle-brachial index (0.68 ± 0.18 to 0.94 ± 0.15; P < .0001). Tack implant treatment of post-PTA dissection was safe, produced reasonable patency, and resulted in low rates of target lesion revascularization. Tack treatment represents a new, minimal metal paradigm for dissection repair that can safely improve the clinical results associated with PTA. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hayton, D. J.; Jenkins, T. E.
2004-02-01
The effects of back-surface reflection from transparent substrates on ellipsometric measurements are discussed and it is shown that their effects can be minimized by placing the substrate on a commercially available product, Blu-tack. The ellipsometric properties of Blu-tack in the range 250 850 nm are presented and the frustration of the back-surface reflection is discussed in terms of index matching between substrate and Blu-tack.
System and method for altering the tack of materials using an electrohydraulic discharge
Banerjee, Sujit; Corcoran, Howard
2007-11-13
A system and method for altering the tack of a material, namely a polymer used as an adhesive, also known as stickies, or pitch. The present invention reduces the tack of the stickies and pitch by exposing the materials for a short duration to low-energy pulsed electrical discharges between a pair of electrodes that are submerged in a liquid medium, such as a fiber stream, water, a pulp slurry, or whitewater.
System and method for altering the tack of materials using an electrohydraulic discharge
Banerjee, Sujit; Corcoran, Howard
2003-01-01
A system and method for altering the tack of a material, namely a polymer used as an adhesive, also known as stickies, or pitch. The present invention reduces the tack of the stickies and pitch by exposing the materials for a short duration to low-energy pulsed electrical discharges between a pair of electrodes that are submerged in a liquid medium, such as a fiber stream, water, a pulp slurry, or whitewater.
Tack coat optimization for HMA overlays laboratory testing.
DOT National Transportation Integrated Search
2008-09-01
Interface bonding between hot-mix asphalt (HMA) overlays and Portland cement concrete (PCC) pavements can be one of the most : significant factors affecting overlay service life. Various factors may affect the bonding condition at the interface, incl...
Evaluation of bond strength between pavement layers.
DOT National Transportation Integrated Search
2005-12-01
The primary objective of this project was to develop a test for measuring the bond strength : between pavement layers. The research was also to evaluate tack coat materials and application : rates for the Alabama Department of Transportation (ALDOT)....
Contribution to the rheological testing of pharmaceutical semisolids.
Siska, B; Snejdrova, E; Machac, I; Dolecek, P; Martiska, J
2018-01-22
Rheological behaviour of pharmaceutical semisolid preparations significantly affects manufacturing process, administration, stability, homogeneity of incorporated drug, accuracy of dosing, adhesion in the place of application, drug release, and resulting therapeutic effect of the product. We performed test of consistency by penetrometry, rotational, oscillation and creep tests, and squeeze and tack tests of model samples to introduce methods suitable for characterization and comparison of semisolids in practice. Penetrometry is a simple method allowing sorting the semisolids to low and high stress-resistant materials but deficient for rheological characterization of semisolids. Value of yield stress, generally considered to be appropriate feature of semisolids, is significantly influenced by the method of testing and the way of evaluation. The hysteresis loops of model semisolids revealed incomplete thixotropy, therefore, three-step thixotropy test was employed. Semisolids showed nonlinear response in the creep phase of tests and partial recovery of structure by storing energy in the recovery phase. Squeeze and tack tests seem to be convenient ways for comparison of semisolids. Our study can contribute to a better understanding of different flow behaviour of semisolids given by different physicochemical properties of excipients and can bring useful approaches to evaluation and comparison of semisolids in practice.
NASA Technical Reports Server (NTRS)
Yin, Q.-Z.; Sanborn, M. E.; Goodrich, C. A.; Zolensky, M.; Fioretti, A. M.; Shaddad, M.; Kohl, I. E.; Young, E. D.
2018-01-01
There is an increasing number of Cr-O-Ti isotope studies that show that solar system materials are divided into two main populations, one carbonaceous chondrite (CC)-like and the other is non-carbonaceous (NCC)-like, with minimal mixing between them attributed to a gap opened in the propoplanetary disk due to Jupiter's formation. The Grand Tack model suggests that there should be a particular time in the disk history when this gap is breached and ensuring a subsequent large-scale mixing between S- and C-type asteroids (inner solar system and outer solar system materials), an idea supported by our recent work on chondrule (Delta)17O-(epsilon)54Cr isotope systematics.
Evaluation of Tack Coat Bond Strength Tests
DOT National Transportation Integrated Search
2018-05-01
Poor bonding between asphalt pavement overlays and the substrate pavement layer can greatly influence the long term performance of hot mix asphalt (HMA) in the form of premature cracking and fatigue. The primary method to achieve bonding between laye...
Schneider, Peter A; Giasolli, Robert; Ebner, Adrian; Virmani, Renu; Granada, Juan F
2015-02-01
This study provides preliminary data on the safety and feasibility of the use of a novel focal implant for managing post-percutaneous transluminal balloon angioplasty (post-PTA) dissection. Post-PTA dissection of the lower extremity arteries is managed with stent placement. This provides an acceptable post-intervention result but has long-term disadvantages, such as in-stent restenosis. Focal treatment of post-PTA dissection and avoidance of stents are the objectives of the Tack-It (Intact Vascular, Inc., Wayne, Pennsylvania) device. A preclinical study and first-in-human data are presented. Seven swine underwent superficial femoral artery device placement, with a self-expanding nitinol stent on 1 side and a series of 4 Tack-It devices on the other side. Specimens were harvested at 28 days. The clinical study included 15 limbs that underwent revascularization for critical limb ischemia (n = 9) or claudication (n = 6). Twenty-five lesions were treated in the superficial femoral (n = 8), popliteal (n = 7), and tibial (n = 10) arteries. The preclinical study demonstrated a reduction in stenosis with the Tack-It (16.8 ± 2.6%) compared with stents (46.4 ± 9.8%). Neointimal thickness and injury score decreased with the Tack-It. Clinically, Tack-It placement resulted in acute technical success with resolution of the post-PTA dissection in 100% of lesions. There were no device-related complications or major amputations. Eighteen of the 25 lesions were available for angiographic follow-up at 1-year, and patency was 83.3%. Preclinical data suggest that the Tack-It device causes minimal vessel injury. Clinical use of the Tack-It to manage post-PTA dissection was safe and feasible in this early study and resulted in apposition of dissection flaps without stent placement. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
HMAC layer adhesion through tack coat.
DOT National Transportation Integrated Search
2017-02-01
Tack coats are the asphaltic emulsions applied between pavement lifts to provide adequate bond between the two surfaces. The adhesive bond between the two layers helps the pavement system to behave as a monolithic structure and improves the structura...
Performance evaluation and specification of trackless tack.
DOT National Transportation Integrated Search
2016-09-01
Several trackless tack products have come to market in Texas; however, there are currently no specifications to : ensure the products have trackless properties and adequate bond strength. The objectives of this project were to : (1) evaluate the trac...
Trackless tack coat materials : a laboratory evaluation performance acceptance.
DOT National Transportation Integrated Search
2012-06-01
The purpose of this study was to develop, demonstrate, and document laboratory procedures that could be used by the : Virginia Department of Transportation (VDOT) to evaluate non-tracking tack coat materials. The procedures would be used to : qualify...
NASA Technical Reports Server (NTRS)
Wiesenbach, W. T.; Clark, M. C.
1983-01-01
Positioner holds coil inside cylinder during tack welding. Welding aid spaces turns of coil inside cylinder and applies contact pressure while coil is tack-welded to cylinder. Device facilitates fabrication of heat exchangers and other structures by eliminating hand-positioning and clamping of individual coil turns.
Investigation of the behavior of asphalt tack coat interface layer.
DOT National Transportation Integrated Search
2005-08-04
Asphalt tack coat is a light application of asphalt, usually asphalt diluted with water. It ensures a bond between the surface being paved and the overlying course by providing increased shear strength between two interfaces. Normally hot asphalt cem...
No-Tack Inlay on Milled Surface: Project Report
DOT National Transportation Integrated Search
1999-02-01
This report documents observation of a construction project west of Nashville, Tennessee that did not use a tack coat during the placement of the hot mix asphalt (HMA). This observation took place on June 23, 1998. For this project, the existing pave...
2014-01-01
Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320
System and method for altering characteristics of materials using an electrohydraulic discharge
Banerjee, Sujit
2003-06-03
System and method for oxidizing contaminants to alter specific properties, such as tack, of contaminants. The present invention reduces the tack of the stickies and pitch by exposing the materials for a short duration to low-energy pulsed electrical discharges between a pair of electrodes that are submerged in a liquid medium, such as a fiber stream, water, a pulp slurry, or whitewater. An electrical discharge in the liquid medium oxidizes materials, which may be dissolved or suspended therein, such as stickies, pitch, sulfide, ink, toner, and other substances, thereby reducing tack, odor, and/or zeta potential, as well as producing other desirable effect.
DISTANT VIEW, BLM TACK SHED ON LEFT, BLM SEED SHED ...
DISTANT VIEW, BLM TACK SHED ON LEFT, BLM SEED SHED AT LEFT CENTER, FIRE DISPATCH OFFICES 1 AND 2 AT RIGHT CENTER, UTILITY BUILDING "B" ON RIGHT. VIEW TO SOUTHWEST. - Cedar City Automotive Repair Shop, 820 North Main Street, Cedar City, Iron County, UT
DOT National Transportation Integrated Search
2017-12-01
The performance of pavement interface bonds affects the integrity of pavement structures. In current practice, tack coats are used to ensure sufficient bonding between asphalt concrete (AC) layers as well as AC and concrete or aggregate base layers. ...
Code of Federal Regulations, 2013 CFR
2013-10-01
... to, the use of flagging, bright eyes, tacks, and paint), cutting, and/or removal of trees or.... We prohibit hunters field dressing deer within 100 feet (30 m) of a road or trail. 22. We prohibit... to, the use of flagging, bright eyes, tacks, and paint), cutting, and/or removal of trees or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... to, the use of flagging, bright eyes, tacks, and paint), cutting, and/or removal of trees or.... We prohibit hunters field dressing deer within 100 feet (30 m) of a road or trail. 22. We prohibit... to, the use of flagging, bright eyes, tacks, and paint), cutting, and/or removal of trees or...
Code of Federal Regulations, 2012 CFR
2012-10-01
... to, the use of flagging, bright eyes, tacks, and paint), cutting, and/or removal of trees or.... We prohibit hunters field dressing deer within 100 feet (30 m) of a road or trail. 22. We prohibit... to, the use of flagging, bright eyes, tacks, and paint), cutting, and/or removal of trees or...
Polyimide Prepregs With Improved Tack
NASA Technical Reports Server (NTRS)
Vanucci, R.
1987-01-01
Drape and tack improved without loss of strength. Composites made with PMR-15 (or equivalent) polyimides have gained acceptance as viable engineering materials for high-use-temperature applications. Acceptance due to both thermo-oxidative stability of PMR-15 (or equivalent) and ease which PMR-15 (or equivalent) prepreg materials processed into composite structures.
Bond expectations for milled surfaces and typical tack coat materials used in Virginia.
DOT National Transportation Integrated Search
2009-01-01
The ultimate purpose of the program of research of which this study was a part is to identify a test method and acceptance criteria for bonding of HMA layers. In this study, three tasks were performed to help achieve that purpose: a laboratory compar...
Code of Federal Regulations, 2011 CFR
2011-10-01
... marking (this includes but is not limited to, the use of flagging, bright eyes, tacks, and paint), cutting... (this includes but is not limited to, the use of flagging, bright eyes, tacks, and paint), cutting, and..., Lily Lake, and the posted fishing areas along the south side of Parkertown Dock Road, North side of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, Christopher H., E-mail: chchap@umich.edu; Nagesh, Vijaya; Sundgren, Pia C.
Purpose: To determine whether early assessment of cerebral white matter degradation can predict late delayed cognitive decline after radiotherapy (RT). Methods and Materials: Ten patients undergoing conformal fractionated brain RT participated in a prospective diffusion tensor magnetic resonance imaging study. Magnetic resonance imaging studies were acquired before RT, at 3 and 6 weeks during RT, and 10, 30, and 78 weeks after starting RT. The diffusivity variables in the parahippocampal cingulum bundle and temporal lobe white matter were computed. A quality-of-life survey and neurocognitive function tests were administered before and after RT at the magnetic resonance imaging follow-up visits. Results:more » In both structures, longitudinal diffusivity ({lambda}{sub Double-Vertical-Line }) decreased and perpendicular diffusivity ({lambda}{sub Up-Tack }) increased after RT, with early changes correlating to later changes (p < .05). The radiation dose correlated with an increase in cingulum {lambda}{sub Up-Tack} at 3 weeks, and patients with >50% of cingula volume receiving >12 Gy had a greater increase in {lambda}{sub Up-Tack} at 3 and 6 weeks (p < .05). The post-RT changes in verbal recall scores correlated linearly with the late changes in cingulum {lambda}{sub Double-Vertical-Line} (30 weeks, p < .02). Using receiver operating characteristic curves, early cingulum {lambda}{sub Double-Vertical-Line} changes predicted for post-RT changes in verbal recall scores (3 and 6 weeks, p < .05). The neurocognitive test scores correlated significantly with the quality-of-life survey results. Conclusions: The correlation between early diffusivity changes in the parahippocampal cingulum and the late decline in verbal recall suggests that diffusion tensor imaging might be useful as a biomarker for predicting late delayed cognitive decline.« less
Effect of synthesis variables on tack in urea-formaldehyde resin
R.J. Leicht; C.Y. Hse; R.C. Tang
1988-01-01
The degree of tack-the ability of resin to adhere to another surface under light pressure and over short time- in urea-formaldehyde resin varies throughout the particle board manufacturing process and affects mill maintenance and board quality. A three-part study was conducted to evaluate the effects of certain synthesis variables- molar formaldehyde:urea ratio,...
ERIC Educational Resources Information Center
Wamsted, John Oliver
2013-01-01
The "urban" mathematics classroom has become an increasingly polarized site, one where many middle-class White teachers attempt to bridge the divide between themselves and their relatively economically disadvantaged, non-White students. With its mania for high-stakes testing, current education policy has intensified the importance of…
NASA Astrophysics Data System (ADS)
Shishlov, N. M.; Akhmetzyanov, Sh S.; Khursan, S. L.
2017-02-01
Experimental IR spectra of crystalline dried and non-dried potassium diphenylsulfophthalide (TAC-K) as a model compound for polymeric salts are presented. DFT analysis (B3LYP/6-311G(d,p)) of the structure and IR spectra of a series of compounds similar in structure to TAC-K as well as their dimers indicates that the sulfonate group environment strongly affects the positions of absorption bands (ABs) of vibrations of Ssbnd O bonds and demonstrates that information on the exact structure of ion clusters is needed for reliable and unambiguous assignment of the ABs in experimental IR spectra of real sulfonate ion containing systems to particular vibrational modes. Various ways of metal ion coordination with sulfonate ion, as well as their reflection in IR spectra of model compounds, are considered and discussed. Using TAC-K as an example, the effect of an intramolecular hydrogen bond on the vibrational modes of sulfonate group and hydroxy group is considered. The effect of ion aggregation on the shape of the IR spectrum of TAC-K is analyzed for an energetically favorable dimer of this salt as an example. Based on a combination of calculated, literature and reference data, a number of ABs in the IR spectra of TAC-K have been tentatively assigned. In particular, the bands in the region of 3230-3180 cm-1 have been assigned to ν(Osbnd H); those at 1240-1160 cm-1, to νas(SO3-); the AB at 1080 cm-1, to νs(SO3-); that at 616 cm-1, to δ(oop)s(SO3-); and that at 570 cm-1, to δ(ip)as(SO3-).
Disk Residual Life Studies. Part 1. F100 1st-Stage Turbine Disk (IN100)
1979-12-01
mag- nifying lens Static FPI was augmented by wink FPI while phase II specimens were installed in the fatigue test machine. This form of inspection...Failure at thermocouple tack weld. Fractography : no cracks in bolthole BR-3 Test Temperatu,-e, = 10000F, o,,, 90 kIoBR- Pretest - No No No Hole honed and... Fractography no cracks in bolthole 44! ! ’ Ai N3Wp IOLTHOLE SPECIMEN Vt 4; TABLESS FATIGUE TEST INSPEC’rIoN RECORDS (Confiilued) Specimen ks.oecoon
Zhao, Chunyi; Quan, Peng; Liu, Chao; Li, Qiaoyun; Fang, Liang
2016-11-01
The purpose of this study was to investigate the effect of isopropyl myristate (IPM), a penetration enhancer, on the viscoelasticity and drug release of a drug-in-adhesive transdermal patch containing blonanserin. The patches were prepared with DURO-TAK ® 87-2287 as a pressure-sensitive adhesive (PSA) containing 5% ( w / w ) of blonanserin and different concentrations of IPM. An in vitro release experiment was performed and the adhesive performance of the drug-in-adhesive patches with different concentrations of IPM was evaluated by a rolling ball tack test and a shear-adhesion test. The glass transition temperature ( T g ) and rheological parameters of the drug-in-adhesive layers were determined to study the effect of IPM on the mechanical properties of the PSA. The results of the in vitro release experiment showed that the release rate of blonanserin increased with an increasing concentration of IPM. The rolling ball tack test and shear-adhesion test showed decreasing values with increasing IPM concentration. The results were interpreted on the basis of the IPM-induced plasticization of the PSA, as evidenced by a depression of the glass transition temperature and a decrease in the elastic modulus. In conclusion, IPM acted as a plasticizer on DURO-TAK ® 87-2287, and it increased the release of blonanserin and affected the adhesive properties of the PSA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hau, L.-N.; Department of Physics, National Central University, Jhongli, Taiwan; Lai, Y.-T.
Harris-type current sheets with the magnetic field model of B-vector=B{sub x}(z)x-caret+B{sub y}(z)y-caret have many important applications to space, astrophysical, and laboratory plasmas for which the temperature or pressure usually exhibits the gyrotropic form of p{r_reversible}=p{sub Parallel-To }b-caretb-caret+p{sub Up-Tack }(I{r_reversible}-b-caretb-caret). Here, p{sub Parallel-To} and p{sub Up-Tack} are, respectively, to be the pressure component along and perpendicular to the local magnetic field, b-caret=B-vector/B. This study presents the general formulation for magnetohydrodynamic (MHD) wave propagation, fire-hose, and mirror instabilities in general Harris-type current sheets. The wave equations are expressed in terms of the four MHD characteristic speeds of fast, intermediate, slow, and cuspmore » waves, and in the local (k{sub Parallel-To },k{sub Up-Tack },z) coordinates. Here, k{sub Parallel-To} and k{sub Up-Tack} are, respectively, to be the wave vector along and perpendicular to the local magnetic field. The parameter regimes for the existence of discrete and resonant modes are identified, which may become unstable at the local fire-hose and mirror instability thresholds. Numerical solutions for discrete eigenmodes are shown for stable and unstable cases. The results have important implications for the anomalous heating and stability of thin current sheets.« less
Design and Evaluation of a Chamber Capable of Containing the Detonation Effects of 40 Pounds of TNT
1975-11-01
Boiler and Pressure Vessel Code , 197A. For the girth welds, short lengths of 26-in.-dia. pipe were tacked to the vessel around the...and tensile tests meet the requirements of Section IX, ASHE Boiler and Pressure Vessel Code , 1974. Weld made by W. H. Stefanov ■.^^ w-^iiMaLwärt...Macro Results Kos, No Remarl.s The results of the bond and it^nsile tests met the requirements of Section IX, ASME Boiler and Pressure
Relationship of Industrial Noise to Hearing Acuity in a Controlled Population
1961-01-01
heel tacker and fiber nailer. The fiber nailer produces seat lasting, toe lasting, tacking and tack pulling , a very sharp impact. lImpa’t-type noises are...criteria are friom person toi liers-in Another possible goali for criteria int ended to leti ne a hia za rdous sit uato or, (con- is that expiosure to...mniewliere in biet weeln. Tile oet ave, ba nd with the in axi nttitn l ottdtnes~s is 2,400- dte j ii k m ot trivial. b eca use design goalIs fori
ERIC Educational Resources Information Center
Lee, Yeung Chung; Kwok, Ping Wai
2010-01-01
Traditional methods used to teach the concept of density that employ solid objects of different masses and volumes can be supplemented by enquiry activities in which students vary the mass-to-volume ratio of the same object to test ideas about density and flotation. A simple substance, Blu-Tack, is an ideal material to use in this case. The…
A multifunctional force microscope for soft matter with in situ imaging
NASA Astrophysics Data System (ADS)
Roberts, Paul; Pilkington, Georgia A.; Wang, Yumo; Frechette, Joelle
2018-04-01
We present the multifunctional force microscope (MFM), a normal and lateral force-measuring instrument with in situ imaging. In the MFM, forces are calculated from the normal and lateral deflection of a cantilever as measured via fiber optic sensors. The motion of the cantilever is controlled normally by a linear micro-translation stage and a piezoelectric actuator, while the lateral motion of the sample is controlled by another linear micro-translation stage. The micro-translation stages allow for travel distances that span 25 mm with a minimum step size of 50 nm, while the piezo has a minimum step size of 0.2 nm, but a 100 μm maximum range. Custom-designed cantilevers allow for the forces to be measured over 4 orders of magnitude (from 50 μN to 1 N). We perform probe tack, friction, and hydrodynamic drainage experiments to demonstrate the sensitivity, versatility, and measurable force range of the instrument.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P.; Howard, S.; Maxwell, D.
During final preparations for start of the PDCF Inner Can (IC) qualification effort, welding was performed on an automated weld system known as the PICN. During the initial weld, using a pedigree canister and plug, a weld defect was observed. The defect resulted in a hole in the sidewall of the canister, and it was observed that the plug sidewall had not been consumed. This was a new type of failure not seen during development and production of legacy Bagless Transfer Cans (FB-Line/Hanford). Therefore, a team was assembled to determine the root cause and to determine if the process couldmore » be improved. After several brain storming sessions (MS and T, R and D Engineering, PDC Project), an evaluation matrix was established to direct this effort. The matrix identified numerous activities that could be taken and then prioritized those activities. This effort was limited by both time and resources (the number of canisters and plugs available for testing was limited). A discovery process was initiated to evaluate the Vendor's IC fabrication process relative to legacy processes. There were no significant findings, however, some information regarding forging/anneal processes could not be obtained. Evaluations were conducted to compare mechanical properties of the PDC canisters relative to the legacy canisters. Some differences were identified, but mechanical properties were determined to be consistent with legacy materials. A number of process changes were also evaluated. A heat treatment procedure was established that could reduce the magnetic characteristics to levels similar to the legacy materials. An in-situ arc annealing process was developed that resulted in improved weld characteristics for test articles. Also several tack welds configurations were addressed, it was found that increasing the number of tack welds (and changing the sequence) resulted in decreased can to plug gaps and a more stable weld for test articles. Incorporating all of the process improvements for the actual can welding process, however, did not result in an improved weld geometry. Several possibilities for the lack of positive response exist, some of which are that (1) an insufficient number of test articles were welded under prototypic conditions, (2) the process was not optimized so that significant improvements were observable over the 'noise', and (3) the in-situ arc anneal closed the gap down too much so the can was unable to exhaust pressure ahead of the weld. Several operational and mechanical improvements were identified. The weld clamps were changed to a design consistent with those used in the legacy operations. A helium puff operation was eliminated; it is believed that this operation was the cause of the original weld defect. Also, timing of plug mast movement was found to correspond with weld irregularities. The timing of the movement was changed to occur during weld head travel between tacks. In the end a three sequential tack weld process followed by a pulse weld at the same current and travel speed as was used for the legacy processes was suggested for use during the IC qualification effort. Relative to legacy welds, the PDC IC weld demonstrates greater fluctuation in the region of the weld located between tack welds. However, canister weld response (canister to canister) is consistent and with the aid of the optical mapping system (for targeting the cut position) is considered adequate. DR measurements and METs show the PDC IC welds to have sufficient ligament length to ensure adequate canister pressure/impact capacity and to ensure adequate stub function. The PDC welding process has not been optimized as a result of this effort. Differences remain between the legacy BTC welds and the PDC IC weld, but these differences are not sufficient to prevent resumption of the current PDC IC qualification effort. During the PDC IC qualification effort, a total of 17 cans will be welded and a variety of tests/inspections will be performed. The extensive data collected during that qualification effort should be of a sufficient population to determine if additional weld process optimization is necessary prior to production release.« less
Cristaudo, Adam; Nayak, Arun; Martin, Sarah; Adib, Reza; Martin, Ian
2015-05-01
The totally extraperitoneal (TEP) approach for surgical repair of inguinal hernias has emerged as a popular technique. We conducted a prospective randomised trial to compare patient comfort scores using different mesh types and fixation using this technique. Over a 14 month period, 146 patients underwent 232 TEP inguinal hernia repairs. We compared the comfort scores of patients who underwent these procedures using different types of mesh and fixation. A non-absorbable 15 × 10 cm anatomical mesh fixed with absorbable tacks (Control group) was compared with either a non-absorbable 15 × 10 cm folding slit mesh with absorbable tacks (Group 2), a partially-absorbable 15 × 10 cm mesh with absorbable tacks (Group 3) or a non-absorbable 15 × 10 cm anatomical mesh fixed with 2 ml fibrin sealant (Group 4). Outcomes were compared at 1, 2, 4 and 12 weeks using the Carolina Comfort Scale (CCS) scores. At 1, 2, 4 and 12 weeks, the median global CCS scores were low for all treatment groups. Statistically significant differences were seen only for median CCS scores and subscores with the use of partially-absorbable mesh with absorbable tacks (Group 3) at weeks 2 and 4. However, these were no longer significant at week 12. In this study, the TEP inguinal hernia repair with minimal fixation results in low CCS scores. There were no statistical differences in CCS scores when comparing types of mesh, configuration of the mesh or fixation methods. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Sanborn, M. E.; Yin, Q.-Z.; Goodrich, C. A.; Zolensky, M.; Fioretti, A. M.
2017-01-01
There is an increasing number of Cr-O-Ti isotope studies that show solar system materials are divided into two main populations, one carbonaceous chondrite (CC)-like and the other is non-carbonaceous (NC)-like, with minimal mixing attributed to a gap opened in the protoplanetary disk due to Jupiter's formation. The Grand Tack model suggests there should be large-scale mixing between S- and C-type asteroids, an idea supported by our recent work on chondrule (Delta)17O-e54Cr isotope systematics. The Almahata Sitta (AhS) meteorite provides a unique opportunity to test the Grand Tack model. The meteorite fell to Earth in October 2008 and has been linked to the asteroid 2008 TC3 which was discovered just prior to the fall of the AhS stones. The AhS meteorite is composed of up to 700 individual pieces with approx.140 of those pieces having some geochemical and/or petrologic studies. Almahata Sitta is an anomalous polymict ureilite with other meteorite components, including enstatite, ordinary, and carbonaceous chondrites with an approximate abundance of 70% ureilites and 30% chondrites. This observation has lead to the suggestion that TC3 2008 was a loosely aggregated rubble pile-like asteroid with the non-ureilite sample clasts within the rubble-pile. Due to the loosely-aggregated nature of AhS, the object disintegrated during atmospheric entry resulting in the weakly held clasts falling predominantly as individual stones in the AhS collection area. However, recent work has identified one sample of AhS, sample 91A, which may represent two different lithologies coexisting within a single stone. The predominate lithology type in 91A appears to be that of a C2 chondrite based on mineralogy but also contains olivine, pyroxene, and albite that have ureilite-like compositions. Previous Cr isotope investigations into AhS stones are sparse and what data is available show nearly uniform isotopic composition similar to that of typical ureilites with negative e54Cr values.
CrossTalk: The Journal of Defense Software Engineering. Volume 24, Number 2, March/April 2011
2011-04-01
and insider at- tacks, we plan to conduct experiments and collect concrete and empirical evidence. As we have done in prior research projects [11...subsequent service failure.” Yet, a faulty state can continue to render service; an er- roneous state cannot. Consider a system that receives concrete ...that does not satisfy specifications. The faults in the concrete are not detected during (faulty) acceptance testing. A two-deck bridge is built using
Structural and tribometric characterization of biomimetically inspired synthetic "insect adhesives"
Speidel, Matthias W; Kleemeier, Malte; Hartwig, Andreas; Rischka, Klaus; Ellermann, Angelika; Daniels, Rolf
2017-01-01
Background: Based on previous chemical analyses of insect tarsal adhesives, we prepared 12 heterogeneous synthetic emulsions mimicking the polar/non-polar principle, analysed their microscopical structure and tested their adhesive, frictional, and rheological properties. Results: The prepared emulsions varied in their consistency from solid rubber-like, over soft elastic, to fluid (watery or oily). With droplet sizes >100 nm, all the emulsions belonged to the common type of macroemulsions. The emulsions of the first generation generally showed broader droplet-size ranges compared with the second generation, especially when less defined components such as petrolatum or waxes were present in the lipophilic fraction of the first generation of emulsions. Some of the prepared emulsions showed a yield point and were Bingham fluids. Tribometric adhesion was tested via probe tack tests. Compared with the "second generation" (containing less viscous components), the "first generation" emulsions were much more adhesive (31–93 mN), a finding attributable to their highly viscous components, i.e., wax, petrolatum, gelatin and poly(vinyl alcohol). In the second generation emulsions, we attained much lower adhesivenesses, ranging between 1–18 mN. The adhesive performance was drastically reduced in the emulsions that contained albumin as the protein component or that lacked protein. Tribometric shear tests were performed at moderate normal loads. Our measured friction forces (4–93 mN in the first and 0.1–5.8 mN in the second generation emulsions) were comparatively low. Differences in shear performance were related to the chemical composition and emulsion structure. Conclusion: By varying their chemical composition, synthetic heterogeneous adhesive emulsions can be adjusted to have diverse consistencies and are able to mimic certain rheological and tribological properties of natural tarsal insect adhesives. PMID:28144564
Radial Mixing and Ru-Mo Isotope Systematics Under Different Accretion Scenarios
NASA Astrophysics Data System (ADS)
Fischer, R. A.; Nimmo, F.; O'Brien, D. P.
2017-12-01
The Ru-Mo isotopic compositions of inner Solar System bodies may reflect the provenance of accreted material and how it evolved with time, both of which are controlled by the accretion scenario these bodies experienced. Here we use a total of 116 N-body simulations of terrestrial planet accretion, run in the Eccentric Jupiter and Saturn (EJS), Circular Jupiter and Saturn (CJS), and Grand Tack scenarios, to model the Ru-Mo anomalies of Earth, Mars, and Theia analogues. This model starts by applying an initial step function in Ru-Mo isotopic composition, with compositions reflecting those in meteorites, and traces compositional evolution as planets accrete. The mass-weighted provenance of the resulting planets reveals more radial mixing in Grand Tack simulations than in EJS/CJS simulations, and more efficient mixing among late-accreted material than during the main phase of accretion in EJS/CJS simulations. We find that an extensive homogenous inner disk region is required to reproduce Earth's observed Ru-Mo composition. EJS/CJS simulations require a homogeneous reservoir in the inner disk extending to ≥3-4 AU (≥74-98% of initial mass) to reproduce Earth's composition, while Grand Tack simulations require a homogeneous reservoir extending to ≥3-10 AU (≥97-99% of initial mass), and likely to ≥7-10 AU. In the Grand Tack model, Jupiter's initial location (the most likely location for a discontinuity in isotopic composition) is 3.5 AU; however, this step location has only a 33% likelihood of producing an Earth with the correct Ru-Mo isotopic signature for the most plausible model conditions. Our results give the testable predictions that Mars has zero Ru anomaly and small or zero Mo anomaly, and the Moon has zero Mo anomaly. These predictions are insensitive to wide variations in parameter choices.
Stability of dry coated solid dosage forms.
Kablitz, Caroline Désirée; Urbanetz, Nora Anne
2009-01-01
The dry coating process was evaluated in terms of storage stability investigating drug release and agglomeration tendency of the different coated oral dosage forms; hydroxypropyl methylcellulose acetate succinate (HPMCAS) was used with triethylcitrate (TEC) as plasticizer and acetylated monoglyceride (Myvacet) as wetting agent. Talc or colloidal silicon dioxide (Aerosil) was used as anti-tacking agents. In contrast to coating formulations consisting of HPMCAS and Myvacet all formulations containing TEC showed enteric resistance and no agglomeration tendency after preparation. After storage at 10% RH +/- 5% enteric resistance is increased slightly. This increase is more pronounced at 60% RH +/- 5%. The formulations without anti-tacking agents showed higher drug releases after 12 and 24 months due to the damage of the film's integrity during sample preparation caused by the high tackiness of the film. Tackiness is not affected by storing if samples are stored at low relative humidity. At high relative humidity tackiness increases upon storage especially for formulations without anti-tacking agents. The sieving results of the agglomeration measurements after storage can be confirmed by ring shear measurements performed immediately after preparation and approved to be a tool, which is able to predict the agglomeration during storage.
Pain and convalescence following laparoscopic ventral hernia repair.
Eriksen, Jens Ravn
2011-12-01
Severe pain is usual after laparoscopic ventral hernia repair (LVHR). Mesh fixation with titanium tacks may play a key role in the development of acute and chronic pain and alternative fixation methods should therefore be investigated. This PhD thesis was based on three studies and aimed too: 1) assess the intensity and impact of postoperative pain by detailed patient-reported description of pain and convalescence after LVHR (Study I), 2) evaluate the feasibility of fibrin sealant (FS) for mesh fixation in an experimental pig model (Study II), and 3) investigate FS vs. tacks for mesh fixation in LVHR in a randomised, double-blinded, clinical controlled study with acute postoperative pain as the primary outcome (Study III). In Study I - a prospective descriptive study - 35 patients were prospectively included and underwent LVHR. Scores of pain, quality of life, convalescence, fatigue, and general well-being were obtained from each patient. Follow-up was six months. Average pain from postoperative day (POD) 0-2 and POD 0-6 measured on a 0-100 mm visual analogue scale (VAS) was 61 and 48, respectively. Pain scores reached preoperative values at POD 30. The incidence of severe chronic pain was 7%. No parameter predicted postoperative pain significantly. Significant correlations were found between pain, and general well-being (rS= -0.8, p < 0.001), satisfaction (rS= -0.67, p < quality of life score (rS= -0.63, p < 0.001) six months postoperatively. Patients resumed normal daily activity at POD 14. In Study II - a randomised experimental study in pigs - nine pigs were operated laparoscopically with insertion of two different meshes fixed with either FS or tacks. All pigs were euthanized on POD 30. The primary outcome parameter was strength of ingrowth between the mesh and the anterior abdominal wall. A mechanical peel test was performed for each tissue sample. The secondary outcome parameters were grade and strength of adhesions to the mesh, shrinkage and displacement/folding of the mesh and histological parameters. All nine pigs survived without complications until sacrifice. No meshes were displaced from their initial position at autopsy, but in two cases mesh folding was observed. No significant difference in strength of ingrowth was found between different fixation methods or mesh types. Furthermore, no significant difference was found in grade or strength of adhesions or any histological parameters. In Study III - a randomised, controlled, double-blinded, multicenter trial - 40 patients with umbilical hernia defects between 1.5-5 cm, were randomly assigned to receive FS or titanium tacks for mesh fixation in LVHR. Patients, care givers and those assessing the outcomes were blinded to group assignment. The primary outcome was average pain from POD 0-2 (VAS score). Secondary outcome parameters were fatigue, general well-being and time to resume normal daily activity. Follow-up was one month for all. Patients in the FS group reported significantly less pain at POD 0-2 (median VAS 38 (range 6-98) vs. 60 (18-96), p = 0.01). Absolute VAS score difference between groups was 20 mm (95% CI 4-35 mm) at activity, and 19 mm (95% CI 3-34 mm) at rest. Patients in the FS group reported significantly less discomfort from POD 0-2 and POD 0-10, compared with the tack group. No significant difference was found in fatigue score between groups. No significant difference in hospital stay, hernia diameter, or morphine consumption in the post anesthesia care unit was found between groups. Patients in the FS group resumed normal daily activity at POD 7 (1-66) versus POD 18 (1-95) in the tack group (p = 0.03). No recurrences were observed. No adverse events or side effects were observed. No significant differences in predefined complications were found between groups. In conclusion, pain is a significant clinical problem after LVHR with impact on general well-being, quality of life and patient satisfaction. This issue must have first priority in future ventral hernia repair research. It is now documented, that the simple application of fibrin glue instead of titanium tacks for mesh fixation in LVHR of defects < 5 cm significantly reduced acute pain, discomfort and the period of convalescence. Long-term follow-up will show the value of FS fixation in terms of chronic pain and recurrence. As FS potentially may solve many of the outcome problems associated with LVHR, future studies should include larger hernia defects including large incisional hernias, as the operative technique may be different.
Tackifier for addition polyimides
NASA Technical Reports Server (NTRS)
Butler, J. M.; St.clair, T. L.
1980-01-01
A modification to the addition polyimide, LaRC-160, was prepared to improve tack and drape and increase prepeg out-time. The essentially solventless, high viscosity laminating resin is synthesized from low cost liquid monomers. The modified version takes advantage of a reactive, liquid plasticizer which is used in place of solvent and helps solve a major problem of maintaining good prepeg tack and drape, or the ability of the prepeg to adhere to adjacent plies and conform to a desired shape during the lay up process. This alternate solventless approach allows both longer life of the polymer prepeg and the processing of low void laminates. This approach appears to be applicable to all addition polyimide systems.
Acrylic Triblock Copolymers Incorporating Isosorbide for Pressure Sensitive Adhesives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallagher, James J.; Hillmyer, Marc A.; Reineke, Theresa M.
A new monomer acetylated acrylic isosorbide (AAI) was prepared in two steps using common reagents without the need for column chromatography. Free radical polymerization of AAI afforded poly(acetylated acrylic isosorbide) (PAAI), which exhibited a glass transition temperature (Tg) = 95 °C and good thermal stability (Td, 5% weight loss; N2 = 331 °C, air = 291 °C). A series of ABA triblock copolymers with either poly(n-butyl acrylate) (PnBA) or poly(2-ethylhexyl acrylate) (PEHA) as the low Tg midblocks and PAAI as the high Tg end blocks were prepared using Reversible Addition–Fragmentation chain Transfer (RAFT) polymerization. The triblock copolymers ranging from 8–24more » wt % PAAI were evaluated as pressure sensitive adhesives by 180° peel, loop tack, and static shear testing. While the PAAI-PEHA-PAAI series exhibited poor adhesive qualities, the PAAI-PnBA-PAAI series of triblock copolymers demonstrated peel forces up to 2.9 N cm–1, tack forces up to 3.2 N cm–1, and no shear failure up to 10000 min. Dynamic mechanical analysis indicated that PAAI-PEHA-PAAI lacked the dissipative qualities needed to form an adhesive bond with the substrate, while the PAAI-PnBA-PAAI series exhibited a dynamic mechanical response consistent with related high performing PSAs.« less
Radial mixing and Ru-Mo isotope systematics under different accretion scenarios
NASA Astrophysics Data System (ADS)
Fischer, Rebecca A.; Nimmo, Francis; O'Brien, David P.
2018-01-01
The Ru-Mo isotopic compositions of inner Solar System bodies may reflect the provenance of accreted material and how it evolved with time, both of which are controlled by the accretion scenario these bodies experienced. Here we use a total of 116 N-body simulations of terrestrial planet accretion, run in the Eccentric Jupiter and Saturn (EJS), Circular Jupiter and Saturn (CJS), and Grand Tack scenarios, to model the Ru-Mo anomalies of Earth, Mars, and Theia analogues. This model starts by applying an initial step function in Ru-Mo isotopic composition, with compositions reflecting those in meteorites, and traces compositional evolution as planets accrete. The mass-weighted provenance of the resulting planets reveals more radial mixing in Grand Tack simulations than in EJS/CJS simulations, and more efficient mixing among late-accreted material than during the main phase of accretion in EJS/CJS simulations. We find that an extensive homogeneous inner disk region is required to reproduce Earth's observed Ru-Mo composition. EJS/CJS simulations require a homogeneous reservoir in the inner disk extending to ≥3-4 AU (≥74-98% of initial mass) to reproduce Earth's composition, while Grand Tack simulations require a homogeneous reservoir extending to ≥3-10 AU (≥97-99% of initial mass), and likely to ≥6-10 AU. In the Grand Tack model, Jupiter's initial location (the most likely location for a discontinuity in isotopic composition) is ∼3.5 AU; however, this step location has only a 33% likelihood of producing an Earth with the correct Ru-Mo isotopic signature for the most plausible model conditions. Our results give the testable predictions that Mars has zero Ru anomaly and small or zero Mo anomaly, and the Moon has zero Mo anomaly. These predictions are insensitive to wide variations in parameter choices.
Luo, Ziming; Li, Kang; Li, Kaijing; Xian, Bikun; Liu, Ying; Yang, Sijing; Xu, Chaochao; Lu, Shoutao; Zhang, Haijun
2018-01-01
Background To develop an effective surgical procedure for cellular scaffold epiretinal implantation in rhesus, facilitating subsequent epiretinal stem cell transplantation. Methods Retinal progenitors were seeded onto a poly(lactic-co-glycolic) acid (PLGA) scaffold. First, the cellular scaffolds were delivered by 18G catheter or retinal forceps into rabbit epiretinal space (n = 50). Then, the cell survival rate was evaluated by Cell Counting Kit-8 (CCK-8). Second, three methods of scaffold fixation, including adhesion after gas-liquid exchange (n = 1), tamponade by hydrogel (n = 1), and fixation by retinal tacks (n = 4), were performed in rhesus monkeys. After one month, fundus photography and SD-OCT were performed to assess the outcomes, and histological examination was performed to evaluate proliferation. Results The cell survival rate was significantly higher in the catheter group. Follow-up examination showed that retinal tack fixation was the only method to maintain the scaffolds attached to host retina for at least 3 weeks, which is the minimal time required for cell integration. Histological staining demonstrated slight glial fibrillary acidic protein (GFAP) accumulation in the retinal tack insertion area. Conclusions The established surgical procedure offers a new insight into research of epiretinal cell replacement therapy in rhesus eyes. The successful delivery and long-term fixation provide a prerequisite for cell migration and integration. PMID:29760741
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tojo, H.; Hatae, T.; Yatsuka, E.
2012-10-15
This paper focuses on a method for measuring the electron temperature (T{sub e}) without knowing the transmissivity using Thomson scattering diagnostic with a double-pass scattering system. Application of this method for measuring the anisotropic T{sub e}, i.e., the T{sub e} in the directions parallel (T{sub e Double-Vertical-Line Double-Vertical-Line }) and perpendicular (T{sub e Up-Tack }) to the magnetic field, is proposed. Simulations based on the designed parameters for a JT-60SA indicate the feasibility of the measurements except in certain T{sub e} ranges, e.g., T{sub e Double-Vertical-Line Double-Vertical-Line }{approx} 3.5T{sub e Up-Tack} at 120 Degree-Sign of the scattering angle.
... Radiation therapy References Geleijns J, Tack D. Medical physics: radiation risks. In: Adam A, Dixon AK, Gillard ... Exposure Read more NIH MedlinePlus Magazine Read more Health Topics A-Z Read more A.D.A. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Disney, M.
1985-01-01
Astronomer Disney has followed a somewhat different tack than that of most popular books on cosmology by concentrating on the notion of hidden (as in not directly observable by its own radiation) matter in the universe.
Acker, Asaf; Perry, Zvi; Reuveni, Haim; Toker, Asaf
2009-02-01
Work dissatisfaction among physicians worldwide continues to rise over the last few decades, mainly due to declining professional prestige, tack of self fulfillment, time pressure and tack of leisure time. Physicians' burnout is a major result of dissatisfaction, causing doctors to leave the medical profession, and to provide lower quality of care. To examine the work satisfaction, quality of life and leisure time of residents in the Soroka University Medical Center. A validated questionnaire was delivered during the second half of 2004 to 252 residents in the Soroka University Medical Center The data was analyzed using the SPSS 12 for windows program. Descriptive analysis, parametric Students' T Test [where p<0.05 was set to be considered valid) and a-parametric Mann Whitney and x2 tests were conducted. A total of 137 residents responded to the questionnaire (response rate of 54.36%]. The residents' satisfaction level was low, mainly due to dissatisfaction with their quality of life. There was no difference in satisfaction between male and female residents. Residents in the early stage of their internship were more satisfied than residents who had completed the first stage in regard to their income (p=0.005). Surgical residents were less satisfied than non-surgical residents (p=0.003), mainly from the work relations with their superiors (p=0.015). The residents at the Soroka University Medical Center were satisfied with their work environment but not with their quality of life and leisure time. Further attention must be given to these matters--a step which will eventually improve patient care, and delay, to some extent, the burnout of physicians.
Splinters and Other Foreign Bodies in the Skin
... FBs: Bullets, BBs, nails, sewing needles, pins, tacks. Fiberglass spicules. Fishhooks: May have a barbed point that ... need removal Tiny plant stickers, cactus spines, or fiberglass spicules that need removal Minor sliver, splinter, or ...
Small intestine mucosal adhesivity to in vivo capsule robot materials.
Terry, Benjamin S; Passernig, Anna C; Hill, Morgan L; Schoen, Jonathan A; Rentschler, Mark E
2012-11-01
Multiple research groups are investigating the feasibility of miniature, swallowable, in vivo, untethered robots that are capable of traversing the small intestine for the purpose of acquiring biometrics and performing simple surgical procedures. A mathematical model of the intraluminal environment will speed the development of these so-called Robotic Capsule Endoscopes (RCEs), and to this end, the authors, in previous work, initiated a comprehensive program for characterizing both the active and passive forces exerted by the small intestine on an RCE-sized solid bolus. In this work, forces due to adhesivity between RCE materials and the mucosa are investigated. The experimental factors are adhesive modality (peel and tack), material (polycarbonate, micropatterned polydimethylsiloxane, stainless steel, and mucosa), and bowel region (proximal, middle, and distal). The mucosa is excised from a fasting pig, stored in lactated ringer's solution at 3 °C, and then tested at room temperature within 43 h of excision. The results show the mean tack strength of the mucosa to engineering materials was 0.198±0.070 mJ cm⁻². The mean peel strength was 0.055±0.016 mJ cm⁻². This study marks the first time, to the authors' knowledge, that adhesivity between small intestinal mucosa and RCE engineering materials has been measured. The adhesivity values acquired from this study will provide a valuable input into analytical and numerical models of the gastrointestinal tract, specifically models that account for the interfacial properties of the tissue. Copyright © 2012 Elsevier Ltd. All rights reserved.
Performance Evaluation and Durability Studies of Adhesive Bonds
NASA Astrophysics Data System (ADS)
Ranade, Shantanu Rajendra
In this thesis, four test approaches were developed to characterize the adhesion performance and durability of adhesive bonds for specific applications in areas spanning from structural adhesive joints to popular confectionaries such as chewing gum. In the first chapter, a double cantilever beam (DCB) specimen geometry is proposed for combinatorial fracture studies of structural adhesive bonds. This specimen geometry enabled the characterization of fracture energy vs. bondline thickness trends through fewer tests than those required during a conventional "one at a time" characterization approach, potentially offering a significant reduction in characterization times. The second chapter investigates the adhesive fracture resistance and crack path selection in adhesive joints containing patterns of discreet localized weak interfaces created using physical vapor deposition of copper. In a DCB specimen tested under mode-I conditions, fracture energy within the patterned regions scaled according to a simple rule of mixture, while reverse R-curve and R-curve type trends were observed in the regions surrounding weak interface patterns. Under mixed mode conditions such that bonding surface with patterns is subjected to axial tension, fracture energy did not show R-curve type trends while it was observed that a crack could be made to avoid exceptionally weak interfaces when loaded such that bonding surface with defects is subjected to axial compression. In the third chapter, an adaptation of the probe tack test is proposed to characterize the adhesion behavior of gum cuds. This test method allowed the introduction of substrates with well-defined surface energies and topologies to study their effects on gum cud adhesion. This approach and reported insights could potentially be useful in developing chewing gum formulations that facilitate easy removal of improperly discarded gum cuds from adhering surfaces. In the fourth chapter we highlight a procedure to obtain insights into the long-term performance of silicone sealants designed for load-bearing applications such as solar panel support sealants. Using small strain constitutive tests and time-temperature-superposition principle, thermal shift factors were obtained and successfully used to characterize the creep rupture master curves for specific joint configurations, leading to insights into delayed failures corresponding to three years through experiments carried out in one month.
A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance.
Berman, A T; Parks, B G
1990-01-01
The mechanical properties of five synthetic fiberglass casting materials were evaluated and compared with the properties of plaster of Paris. Two of the tests were designed to bear clinical relevance and the third to determine intrinsic material properties. The effect of water on strength degradation was also evaluated. It was found that the synthetics as a group are far superior to plaster of Paris in all methods of testing and that, among the synthetics, KCast Tack Free, Deltalite "S", and KCast Improved were the stronger materials. Clinically, the most important results are that the synthetics attain their relatively high strength in a much shorter time frame than does plaster of Paris, and retain 70-90% of their strength after being immersed in water and allowed to dry.
Implementation impacts : volume 2, summer 2013.
DOT National Transportation Integrated Search
2013-01-01
Summary of research projects at the Louisiana Transportation Research Center. Projects in this issue include: : LTRC Project No. 06-4B, Optimization of Tack Coat for HMA Placement; : LTRC Project No. 10-2GT, : Geotechnical Information Database, Phase...
33 CFR 334.860 - San Diego Bay, Calif., Naval Amphibious Base; restricted area.
Code of Federal Regulations, 2010 CFR
2010-07-01
... vessels under sail, necessary tacking shall constitute a direct route. (4) The regulations in this section... agencies as he/she shall designate. Organized activities (such as sail races and regattas) within the...
33 CFR 334.860 - San Diego Bay, Calif., Naval Amphibious Base; restricted area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... vessels under sail, necessary tacking shall constitute a direct route. (4) The regulations in this section... agencies as he/she shall designate. Organized activities (such as sail races and regattas) within the...
NASA Astrophysics Data System (ADS)
Qian, Ye
Characterization of structural rebuilding and shear migration in cementitious materials in consideration of thixotropy Ye Qian From initial contact with water until hardening, and deterioration, cement and concrete materials are subjected to various chemical and physical transformations and environmental impacts. This thesis focuses on the properties during the fresh state, shortly after mixing until the induction period. During this period flow history, including shearing and resting, and hydration both play big roles in determining the rheological properties. The rheological properties of cement and concrete not only affect the casting and pumping process, but also very critical for harden properties and durability properties. Compared with conventional concrete, self-consolidating concrete (SCC) can introduce many advantages in construction application. These include readiness to apply, decreasing labor necessary for casting, and enhancing hardened properties. However, challenges still remain, such as issues relating to formwork pressure and multi-layer casting. Each of these issues is closely related to the property of thixotropy. From the microstructural point of view, thixotropy is described as structural buildup (flocculation) under rest and breakdown (deflocculation) under flow. For SCC, as well as other concrete systems, it is about balancing sufficient flowability during casting and rate of structural buildup after placement for the application at hand. For instance, relating to the issue of SCC formwork, it is ideal for the material to be highly flowable to achieve rapid casting, but then exhibit high rate of structural buildup to reduce formwork pressure. This can reduce the cost of formwork and reduce the risk of formwork failure. It is apparent that accurately quantifying the two aspects of thixotropy, i.e. structuration and destructuration, is key to tackling these challenges in field application. Thus, the overall objective of my doctoral study is to improve quantification of key parameters tied to thixotropy that we have identified to be important: static yield stress, cohesion and degree of shear-induced particle migration. The two main contributions are as follows: Firstly, I quantified structuration of fresh paste and mortar systems by measuring static yield stress. After an extensive review of various rheological methods to probe viscoelastic properties of yield stress fluids, I selected, developed, and implemented a creep recovery protocol. Creep results were supplemented by low-amplitude oscillatory shear results, and supported that the measured static yield stress corresponds to the solid-liquid transition. This improved quantification of static yield stress can help better understand the effect of mix composition on SCC formwork pressure development, as well as static segregation and stability. Since the static yield stress is measured before the structure is broken down, the effects of sand migration are eliminated. This study also analyzed effects of other supplementary cementitous materials such as nanoclay and fly ash. Results showed that nanoclay effectively increases static yield stress and structuration rate, while fly ash decreases static yield stress. To complement this investigation, I studied cohesion using the probe tack test, as cohesion is widely cited to be closely related to formwork pressure. I verified that probe tack test is a quick and useful method to measure static cohesion. Results showed that nanoclay increased cohesion dramatically while fly ash did not have an apparent effect on cohesion. Secondly, I developed an empirical model to fit the stress decay process under constant shear rate, For mortar systems, the stress decay can be attributed to two mechanisms: colloidal destructuration and sand migration. Such a model could be used to characterize particle migration and dynamic segregation, a critical issue for casting applications. In addition, shear induced particle migration is a widely recognized challenge in characterizing mortars and concretes through shear rheological methods. Therefore this model can help determine the range of shear rates within which migration can be minimized to guide the design of protocols for dynamic rheological characterization and to ultimately develop design strategies to minimize mitigation. Compared with currently existing methods, this model provides a faster approach to quantify the sand migration process, including kinetics.
Dorsal Phalloplasty to Preserve Penis Length after Penile Prosthesis Implantation
Shaeer, Osama; Shaeer, Kamal; Rahman, Islam A.
2017-01-01
Objectives Following penile prosthesis implantation (PPI), patients may complain of a decrease in visible penis length. A dorsal phalloplasty defines the penopubic junction by tacking pubic skin to the pubis, revealing the base of the penis. This study aimed to evaluate the efficacy of a dorsal phalloplasty in increasing the visible penis length following PPI. Methods An inflatable penile prosthesis was implanted in 13 patients with severe erectile dysfunction (ED) at the Kamal Shaeer Hospital, Cairo, Egypt, from January 2013 to May 2014. During the surgery, nonabsorbable tacking sutures were used to pin the pubic skin to the pubis through the same penoscrotal incision. Intraoperative penis length was measured before and after the dorsal phalloplasty. Overall patient satisfaction was measured on a 5-point rating scale and patients were requested to subjectively compare their postoperative penis length with memories of their penis length before the onset of ED. Results Intraoperatively, the dorsal phalloplasty increased the visible length of the erect penis by an average of 25.6%. The average length before and after tacking was 10.2 ± 2.9 cm and 13.7 ± 2.8 cm, respectively (P <0.002). Postoperatively, seven patients (53.8%) reported a longer penis, five patients (38.5%) reported no change in length and one patient (7.7%) reported a slightly shorter penis. The mean overall patient satisfaction score was 4.9 ± 0.3. None of the patients developed postoperative complications. Conclusion A dorsal phalloplasty during PPI is an effective method of increasing visible penis length, therefore minimising the impression of a shorter penis after implantation. PMID:28417025
Numerical simulation of current-free double layers created in a helicon plasma device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, Sathyanarayan; Singh, Nagendra
2012-09-15
Two-dimensional simulations reveal that when radially confined source plasma with magnetized electrons and unmagnetized ions expands into diverging magnetic field B, a current-free double layer (CFDL) embedded in a conical density structure forms, as experimentally measured in the Australian helicon plasma device (HPD). The magnetized electrons follow the diverging B while the unmagnetized ions tend to flow directly downstream of the source, resulting in a radial electric field (E{sub Up-Tack }) structure, which couples the ion and electron flows. Ions are transversely (radially) accelerated by E{sub Up-Tack} on the high potential side of the double layer in the CFDL. Themore » accelerated ions are trapped near the conical surface, where E{sub Up-Tack} reverses direction. The potential structure of the CFDL is U-shaped and the plasma density is enhanced on the conical surface. The plasma density is severely depleted downstream of the parallel potential drop ({phi}{sub Double-Vertical-Line Double-Vertical-Line o}) in the CFDL; the density depletion and the potential drop are related by quasi-neutrality condition, including the divergence in the magnetic field and in the plasma flow in the conical structure. The potential and density structures, the CFDL spatial size, its electric field strengths and the electron and ion velocities and energy distributions in the CFDL are found to be in good agreements with those measured in the Australian experiment. The applicability of our results to measured axial potential profiles in magnetic nozzle experiments in HPDs is discussed.« less
Eriksen, J R; Bisgaard, T; Assaadzadeh, S; Jorgensen, L N; Rosenberg, J
2013-08-01
Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown. We performed a randomized controlled trial including patients with umbilical hernia defects from 1.5 to 5 cm at three Danish hernia centres. We used a 12 cm circular mesh. Participants were randomized to fibrin sealant or titanium tack fixation. Patients were seen in the outpatient clinic at 1 and 12 months follow-up. Forty patients were included of whom 34 were available for intention to treat analysis after 1 year. There were no significant differences in pain, discomfort, fatigue, satisfaction or quality of life between the two groups at the 1-year follow-up. Five patients (26 %) in the fibrin sealant group and one (6 %) in the tack group were diagnosed with a recurrence at the 1-year follow-up (p = 0.182) (overall recurrence rate 17 %). Hernia defects in patients with recurrence were significantly larger than in those without recurrence (median 4.0 vs. 2.8 cm, p = 0.009). Patients with larger hernia defects and fibrin sealant mesh fixation had higher recurrence rates than expected, although the study was not powered for assessment of recurrence. There was no significant difference between groups in any parameters after the 1-year follow-up. The beneficial effects of mesh fixation with fibrin sealant on early outcome warrant further studies on optimization of the surgical technique to prevent recurrence.
Evaluation of erosion and siltation control fabrics.
DOT National Transportation Integrated Search
1976-01-01
New proprietary products in three areas of siltation and erosion control were evaluated. Hold/Gro and Griffnet materials were evaluated for use as slope stabilizers and were compared with the Department's present method of straw tacked with an asphal...
Investigation of asphalt content design for open-graded bituminous mixes.
DOT National Transportation Integrated Search
1974-01-01
Several design procedures associated with determining the proper asphalt content for open-graded bituminous mixes were investigated. Also considered was the proper amount of tack coat that should be placed on the old surface prior to paving operation...
Mulch evaluation and managing vegetation in medians : final report.
DOT National Transportation Integrated Search
1980-01-01
Experiments show best erosion control and vegetation with straw mulch, all wood or paper fiber mulches being suitable tacking agents at rates of 750 lb/A. When used alone, standard woodfiber generally gave better vegetative cover than paperfiber; how...
Evaluation of tack coating practices for asphalt overlays in Nebraska.
DOT National Transportation Integrated Search
2017-04-03
The strength of the bond between asphalt layers affects the lifespan of pavement structures. It is also a key factor in preventing major pavement distresses, such as slippage cracking and delamination. This research project evaluates and compares the...
Lyme disease testing in children in an endemic area.
Al-Sharif, Bashar; Hall, Matthew C
2011-10-01
The purpose of this study was to determine clinician adherence to recommendations regarding diagnostic testing for Lyme disease (LD). The specific aims were to determine the rate of inappropriate test ordering for a diagnosis of erythema migrans and tack of confirmatory test ordering for positive LD screening tests. Using the data warehouse of Marshfield Clinic Research Foundation's Bioinformatics Research Center, cases were identified from 2002 through 2007. A retrospective chart abstraction was performed using Marshfield Clinic's electronic medical record. The study involved children (<19 years old). In 57% of cases, LD testing occurred after a clinical diagnosis of erythema migrans was made. Patients with any symptom in addition to erythema migrans were more likely to have testing (odds ratio (OR) = 3.52, 1.75-7.08). A positive LD screening test was not confirmed 24% of the time. Lack of ordering confirmatory testing was not associated with any clinical factors or site of the evaluation. This study found that some clinicians in an LD-endemic area do not follow guidelines for diagnosing children suspected to have Lyme disease.
Melo Freire, C A; Borges, G A; Caldas, Dbm; Santos, R S; Ignácio, S A; Mazur, R F
To evaluate the cement line thickness and the interface quality in milled or injected lithium disilicate ceramic restorations and their influence on marginal adaptation using different cement types and different adhesive cementation techniques. Sixty-four bovine teeth were prepared for full crown restoration (7.0±0.5 mm in height, 8.0 mm in cervical diameter, and 4.2 mm in incisal diameter) and were divided into two groups: CAD/CAM automation technology, IPS e.max CAD (CAD), and isostatic injection by heat technology, IPS e.max Press (PRESS). RelyX ARC (ARC) and RelyX U200 resin cements were used as luting agents in two activation methods: initial self-activation and light pre-activation for one second (tack-cure). Next, the specimens were stored in distilled water at 23°C ± 2°C for 72 hours. The cement line thickness was measured in micrometers, and the interface quality received scores according to the characteristics and sealing aspects. The evaluations were performed with an optical microscope, and scanning electron microscope images were presented to demonstrate the various features found in the cement line. For the cement line thickness, data were analyzed with three-way analysis of variance (ANOVA) and the Games-Howell test (α=0.05). For the variable interface quality, the data were analyzed with the Mann-Whitney U-test, the Kruskal-Wallis test, and multiple comparisons nonparametric Dunn test (α=0.05). The ANOVA presented statistical differences among the ceramic restoration manufacturing methods as well as a significant interaction between the manufacturing methods and types of cement (p<0.05). The U200 presented lower cement line thickness values when compared to the ARC with both cementation techniques (p<0.05). With regard to the interface quality, the Mann-Whitney U-test and the Kruskal-Wallis test demonstrated statistical differences between the ceramic restoration manufacturing methods and cementation techniques. The PRESS ceramics obtained lower scores than did the CAD ceramics when using ARC cement (p<0.05). Milled restorations cemented with self-adhesive resin cement resulted in a thinner cement line that is statistically different from that of CAD or pressed ceramics cemented with resin cement with adhesive application. No difference between one-second tack-cure and self-activation was noted.
Erosion prevention during highway construction by the use of sprayed on chemicals.
DOT National Transportation Integrated Search
1972-01-01
The purpose of this study was to evaluate the erosion inhibiting potential of nine commercial spray on plastic chemicals. All chemicals were also compared with the conventional method of straw tacked with an asphalt emulsion, and with untreated soil....
Evaluation of Tack Coat Materials on Longitudinal Joints in Louisiana
DOT National Transportation Integrated Search
2018-02-01
One of the advantages of asphalt pavements is that they can minimize traffic disruptions by being paved and opened to traffic quickly. Often, asphalt paving is performed while traffic is maintained in an adjacent lane. The disadvantage of this constr...
ERIC Educational Resources Information Center
Palmaccio, Richard J.
1982-01-01
A method of using vector analysis is presented that is an application of calculus that helps to find the best angle for tacking a boat into the wind. While the discussion is theoretical, it is seen as a good illustration of mathematical investigation of a given situation. (MP)
The origin of inner Solar System water
NASA Astrophysics Data System (ADS)
Alexander, Conel M. O'D.
2017-04-01
Of the potential volatile sources for the terrestrial planets, the CI and CM carbonaceous chondrites are closest to the planets' bulk H and N isotopic compositions. For the Earth, the addition of approximately 2-4 wt% of CI/CM material to a volatile-depleted proto-Earth can explain the abundances of many of the most volatile elements, although some solar-like material is also required. Two dynamical models of terrestrial planet formation predict that the carbonaceous chondrites formed either in the asteroid belt (`classical' model) or in the outer Solar System (5-15 AU in the Grand Tack model). To test these models, at present the H isotopes of water are the most promising indicators of formation location because they should have become increasingly D-rich with distance from the Sun. The estimated initial H isotopic compositions of water accreted by the CI, CM, CR and Tagish Lake carbonaceous chondrites were much more D-poor than measured outer Solar System objects. A similar pattern is seen for N isotopes. The D-poor compositions reflect incomplete re-equilibration with H2 in the inner Solar System, which is also consistent with the O isotopes of chondritic water. On balance, it seems that the carbonaceous chondrites and their water did not form very far out in the disc, almost certainly not beyond the orbit of Saturn when its moons formed (approx. 3-7 AU in the Grand Tack model) and possibly close to where they are found today. This article is part of the themed issue 'The origin, history and role of water in the evolution of the inner Solar System'.
Gregori, Ninel Z; Callaway, Natalia F; Hoeppner, Catherine; Yuan, Alex; Rachitskaya, Aleksandra; Feuer, William; Ameri, Hossein; Arevalo, J Fernando; Augustin, Albert J; Birch, David G; Dagnelie, Gislin; Grisanti, Salvatore; Davis, Janet L; Hahn, Paul; Handa, James T; Ho, Allen C; Huang, Suber S; Humayun, Mark S; Iezzi, Raymond; Jayasundera, K Thiran; Kokame, Gregg T; Lam, Byron L; Lim, Jennifer I; Mandava, Naresh; Montezuma, Sandra R; Olmos de Koo, Lisa; Szurman, Peter; Vajzovic, Lejla; Wiedemann, Peter; Weiland, James; Yan, Jiong; Zacks, David N
2018-06-22
To assess the retinal anatomy and array position in the Argus II Retinal Prosthesis recipients. Prospective, non-comparative cohort study METHODS: Setting: international multicenter study PATIENTS: Argus II recipients enrolled in the Post-Market Surveillance Studies. Spectral-domain Optical Coherence Tomography images collected for the Surveillance Studies (NCT01860092 and NCT01490827) were reviewed. Baseline and postoperative macular thickness, electrode-retina distance (gap), optic disc-array overlap, and preretinal membrane presence were recorded at 1, 3, 6, and 12 months. Axial retinal thickness and axial gap along the array's long axis (a line between the tack and handle), maximal retinal thickness and maximal gap along a B-scan near the tack, midline, and handle. Thirty-three patients from 16 surgical sites in the United States and Germany were included. Mean axial retinal thickness increased from month 1 through month 12 at each location, but reached statistical significance only at the array midline (p-value=0.007). The rate of maximal thickness increase was highest near the array midline (slope=6.02, p=0.004), compared to the tack (slope=3.60, p<0.001) or the handle (slope=1.93, p=0.368). The mean axial and maximal gaps decreased over the study period, and the mean maximal gap size decrease was significant at midline (p=0.032). Optic disc-array overlap was seen in the minority of patients. Preretinal membranes were common before and after implantation. Progressive macular thickening under the array was common and corresponded to decreased electrode-retina gap over time. By month 12, the array was completely apposed to the macula in approximately half of the eyes. Copyright © 2018. Published by Elsevier Inc.
DOT National Transportation Integrated Search
2005-02-01
This report presents the research undertaken within two areas of study of thin asphalt concrete (AC) overlays to rehabilitate : continuously reinforced concrete pavements (CRCP). The first one is the development of a decision tree for the project : s...
Disability Studies in the Composition Classroom
ERIC Educational Resources Information Center
Browning, Ella R.
2014-01-01
Although attention to disability is becoming more apparent in first-year composition curricula, too often disability is simply "tacked on" to existing courses. Scholars have argued that composition instructors interested in fully integrating a disability studies perspective into their curriculum would do well, instead, to think…
Lopez, Aitziber; Degrandi-Contraires, Elise; Canetta, Elisabetta; Creton, Costantino; Keddie, Joseph L; Asua, José M
2011-04-05
Waterborne polyurethane-acrylic hybrid nanoparticles for application as pressure-sensitive adhesives (PSAs) were prepared by one-step miniemulsion polymerization. The addition of polyurethane to a standard waterborne acrylic formulation results in a large increase in the cohesive strength and hence a much higher shear holding time (greater than seven weeks at room temperature), which is a very desirable characteristic for PSAs. However, with the increase in cohesion, there is a decrease in the relative viscous component, and hence there is a decrease in the tack energy. The presence of a small concentration of methyl methacrylate (MMA) in the acrylic copolymer led to phase separation within the particles and created a hemispherical morphology. The tack energy was particularly low in the hybrid containing MMA because of the effects of lower energy dissipation and greater cross-linking. These results highlight the great sensitivity of the viscoelastic and adhesive properties to the details of the polymer network architecture and hence to the precise composition and synthesis conditions.
The development of an alternative thermoplastic powder prepregging technique
NASA Technical Reports Server (NTRS)
Ogden, A. L.; Hyer, M. W.; Wilkes, G. L.; Loos, A. C.
1992-01-01
An alternative powder prepregging technique is discussed that is based on the deposition of powder onto carbon fibers that have been moistened using an ultrasonic humidifier. The dry fiber tow is initially spread to allow a greater amount of the fiber surface to be exposed to the powder, thus ensuring a significant amount of intimate contact between the fiber and the matrix. Moisture in the form of ultrafine water droplets is then deposited onto the spread fiber tow. The moisture promotes adhesion to the fiber until the powder can be tacked to the fibers by melting. Powdered resin is then sieved onto the fibers and then tacked onto the fibers by quick heating in a convective oven. This study focuses on the production of prepregs and laminates made with LaRC-TPI (thermoplastic polyimide) using this process. Although the process appears to be successful, early evaluation was hampered by poor interfacial adhesion. The adhesion problem, however, seems to be the result of a material system incompatibility, rather than being influenced by the process.
ERIC Educational Resources Information Center
Angier, Natalie
1983-01-01
The Computer Museum in Marlborough, Massachusetts houses old and not-so-old calculators, famous old computers and parts of computers, photographs and assorted memorabilia, computer-generated murals, and even a computer made of Tinkertoys that plays tick-tack-toe. The development of the museum and selected exhibits is described. (Author/JN)
High Spin Isomers and Super Heavy Elements (SHE) Synthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popescu, Domitian G.
2010-04-30
To get closer to the SHE-Island the new radioactive beams are proposed for future fusion reaction. We suggest something different: to use the advantage of High Spin Isomer States, by tacking into account the importance of the G (spin-isospin cupling) suggested by Ripka 1.
School Districts Try a New Tack.
ERIC Educational Resources Information Center
Spitz, James A., Jr., Battaglia, Michael
1997-01-01
Politicians are increasingly pressuring school districts to improve instruction while holding down costs. To achieve this aim, western New York school districts are experimenting with mutual gains bargaining, an alternative negotiation process based on Roger Fisher and William Ury's 1991 book "Getting to Yes." Instead of bargaining from…
Interior view of west main room in original tworoom portion. ...
Interior view of west main room in original two-room portion. Note muslin ceiling temporarily tacked up by the HABS team to afford clearer view. Camera facing west. - Warner Ranch, Ranch House, San Felipe Road (State Highway S2), Warner Springs, San Diego County, CA
ERIC Educational Resources Information Center
Greenslade, Thomas B., Jr.
2011-01-01
The geometrical shapes in Fig. 1 recently came into the Greenslade Collection. The semi-triangular pieces of wood looked like slices from a pie, each 22.5 degrees in angular width. They were tied together with a thin leather band tacked around their curved surfaces. What is this apparatus?
Western European and NATO Navies, 1980.
1981-08-01
the mid-1990s. 2 All cruisers, destroyers, and frigates with area-defense SAM 3Destroyers and large frigates beginning with Aconit (1970) 4 Modern...light frigates and large frigates built before Aconit - 19 - tack craft in these navies tend to be concentrated on the northern and southern flanks. In
Toward a Phenomenological-Longitudinal Model of Media Gratification Processes.
ERIC Educational Resources Information Center
Kielwasser, Alfred P.; And Others
While not dismissing the "uses and gratifications" approach to research, this paper attempts to increase the theoretical and practical utility of gratifications measures by approaching them through a more phenomenological and longitudinal tack. The paper suggests that any "gratification unit" is given a unique meaning by the…
Quantifying external focus of attention in sailing by means of action sport cameras.
Pluijms, Joost P; Cañal-Bruland, Rouwen; Hoozemans, Marco J M; Van Beek, Morris W; Böcker, Kaj; Savelsbergh, Geert J P
2016-08-01
The aim of the current study was twofold: (1) to validate the use of action sport cameras for quantifying focus of visual attention in sailing and (2) to apply this method to examine whether an external focus of attention is associated with better performance in upwind sailing. To test the validity of this novel quantification method, we first calculated the agreement between gaze location measures and head orientation measures in 13 sailors sailing upwind during training regattas using a head mounted eye tracker. The results confirmed that for measuring visual focus of attention in upwind sailing, the agreement for the two measures was high (intraclass correlation coefficient (ICC) = 0.97) and the 95% limits of agreement were acceptable (between -8.0% and 14.6%). In a next step, we quantified the focus of visual attention in sailing upwind as fast as possible by means of an action sport camera. We captured sailing performance, operationalised as boat speed in the direction of the wind, and environmental conditions using a GPS, compass and wind meter. Four trials, each lasting 1 min, were analysed for 15 sailors each, resulting in a total of 30 upwind speed trials on port tack and 30 upwind speed trials on starboard tack. The results revealed that in sailing - within constantly changing environments - the focus of attention is not a significant predictor for better upwind sailing performances. This implicates that neither external nor internal foci of attention was per se correlated with better performances. Rather, relatively large interindividual differences seem to indicate that different visual attention strategies can lead to similar performance outcomes.
The origin of inner Solar System water.
Alexander, Conel M O'D
2017-05-28
Of the potential volatile sources for the terrestrial planets, the CI and CM carbonaceous chondrites are closest to the planets' bulk H and N isotopic compositions. For the Earth, the addition of approximately 2-4 wt% of CI/CM material to a volatile-depleted proto-Earth can explain the abundances of many of the most volatile elements, although some solar-like material is also required. Two dynamical models of terrestrial planet formation predict that the carbonaceous chondrites formed either in the asteroid belt ('classical' model) or in the outer Solar System (5-15 AU in the Grand Tack model). To test these models, at present the H isotopes of water are the most promising indicators of formation location because they should have become increasingly D-rich with distance from the Sun. The estimated initial H isotopic compositions of water accreted by the CI, CM, CR and Tagish Lake carbonaceous chondrites were much more D-poor than measured outer Solar System objects. A similar pattern is seen for N isotopes. The D-poor compositions reflect incomplete re-equilibration with H 2 in the inner Solar System, which is also consistent with the O isotopes of chondritic water. On balance, it seems that the carbonaceous chondrites and their water did not form very far out in the disc, almost certainly not beyond the orbit of Saturn when its moons formed (approx. 3-7 AU in the Grand Tack model) and possibly close to where they are found today.This article is part of the themed issue 'The origin, history and role of water in the evolution of the inner Solar System'. © 2017 The Author(s).
NASA Technical Reports Server (NTRS)
2012-01-01
Topics covered include: Mars Science Laboratory Drill; Ultra-Compact Motor Controller; A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator; Shape Memory Composite Hybrid Hinge; Binding Causes of Printed Wiring Assemblies with Card-Loks; Coring Sample Acquisition Tool; Joining and Assembly of Bulk Metallic Glass Composites Through Capacitive Discharge; 670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF; Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer; Discontinuous Mode Power Supply; Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI; Hardware for Accelerating N-Modular Redundant Systems for High-Reliability Computing; Blocking Filters with Enhanced Throughput for X-Ray Microcalorimetry; High-Thermal-Conductivity Fabrics; Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes; Electrospun Nanofiber Coating of Fiber Materials: A Composite Toughening Approach; Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms; Saliva Preservative for Diagnostic Purposes; Hands-Free Transcranial Color Doppler Probe; Aerosol and Surface Parameter Retrievals for a Multi-Angle, Multiband Spectrometer LogScope; TraceContract; AIRS Maps from Space Processing Software; POSTMAN: Point of Sail Tacking for Maritime Autonomous Navigation; Space Operations Learning Center; OVERSMART Reporting Tool for Flow Computations Over Large Grid Systems; Large Eddy Simulation (LES) of Particle-Laden Temporal Mixing Layers; Projection of Stabilized Aerial Imagery Onto Digital Elevation Maps for Geo-Rectified and Jitter-Free Viewing; Iterative Transform Phase Diversity: An Image-Based Object and Wavefront Recovery; 3D Drop Size Distribution Extrapolation Algorithm Using a Single Disdrometer; Social Networking Adapted for Distributed Scientific Collaboration; General Methodology for Designing Spacecraft Trajectories; Hemispherical Field-of-View Above-Water Surface Imager for Submarines; and Quantum-Well Infrared Photodetector (QWIP) Focal Plane Assembly.
Constructing Learning: Using Technology to Support Teaching for Understanding
ERIC Educational Resources Information Center
Sherman,Thomas M.; Kurshan, Barbara L.
2005-01-01
A frequent criticism of technology applications in classrooms is that they are little more than extraneous bells and whistles pointlessly tacked onto routine instruction. The flash and splash of a PowerPoint presentation may look good, but many question the value added to student learning. This leads to the question, how can technologies genuinely…
DISTANT VIEW, AUTOMOTIVE REPAIR SHOP ON LEFT AND UTILITY BUILDING ...
DISTANT VIEW, AUTOMOTIVE REPAIR SHOP ON LEFT AND UTILITY BUILDING "B" ON RIGHT. HOSE WINDING SHED ADJACENT TO SHED-ROOFED ADDITION ON THE UTILITY BUILDING, BLM SEED SHED AND TACK SHED VISIBLE IN FAR DISTANCE. VIEW TO EAST/ - Cedar City Automotive Repair Shop, 820 North Main Street, Cedar City, Iron County, UT
Illegal Procedure? Title IX and Sexual Assault
ERIC Educational Resources Information Center
Sullivan, Ariel
2015-01-01
Many higher education institutions are scrutinized by their campus community and the media for the way that they respond, or fail to respond, to allegations of sexual assault. Tack on the fact that nearly 100 colleges and universities are currently under investigation by the U.S. Department of Education's Office for Civil Rights (OCR) for possible…
Dua, R; Nandlal, B
2004-03-01
The present study was conducted to compare and evaluate the tensile strength of silver soldered joints of stainless steel and cobalt-chromium orthodontic wires with band material. An attempt was made to observe the effect of joint site preparation by incorporation of tack welding and increasing metal to metal surface contact area by flattening an end of the wire prior to soldering along with the regularly used round wires without tack welding. A total of 180 wire specimens were soldered to 180 band specimens. Fifteen samples according to joint site preparation were included for each of the wire groups i.e. Gloria (S.S.), Remanium (S.S.) and Remaloy (Co-Cr) wires of 0.036" in diameter. The findings of the study were suggestive that all three wires may be used for preparing silver soldered joints irrespective of the quality of the wire. However, when subjecting the wire to joint site preparation, Gloria (S.S.) wire showed less tensile strength as compared to Remanium and Remaloy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castelle, Cindy; Wrighton, Kelly C.; Thomas, Brian C.
Domain Archaea is currently represented by one phylum (Euryarchaeota) and two superphyla (TACK and DPANN). However, gene surveys indicate the existence of a vast diversity of uncultivated archaea for which metabolic information is lacking. We sequenced DNA from complex sediment- and groundwater-associated microbial communities sampled prior to and during an acetate biostimulation field experiment to investigate the diversity and physiology of uncultivated subsurface archaea. We sampled 15 genomes that improve resolution of a new phylum within the TACK superphylum and 119 DPANN genomes that highlight a major subdivision within the archaeal domain that separates DPANN from TACK/Euryarchaeota lineages. Within themore » DPANN superphylum, which lacks any isolated representatives, we defined two new phyla using sequences from 100 newly sampled genomes. The first new phylum, for which we propose the name Woesearchaeota, was defined using 54 new sequences. We reconstructed a complete (finished) genome for an archaeon from this phylum that is only 0.8 Mb in length and lacks almost all core biosynthetic pathways, but has genes encoding enzymes predicted to interact with bacterial cell walls, consistent with a symbiotic lifestyle. The second new phylum, for which we propose the name Pacearchaeota, was defined based on 46 newly sampled archaeal genomes. This phylum includes the first non-methanogen with an intermediate Type II/III RuBisCO. We also reconstructed a complete (1.24 Mb) genome for another DPANN archaeon, a member of the Diapherotrites phylum. Metabolic prediction and transcriptomic data indicate that this organism has a fermentation-based lifestyle. In fact, genomic analyses consistently indicate lack of recognizable pathways for sulfur, nitrogen, methane, oxygen, and metal cycling, and suggest that symbiotic and fermentation-based lifestyles are widespread across the DPANN superphylum. Thus, as for a recently identified superphylum of bacteria with small genomes and no cultivated representatives, the biogeochemical impacts of this major radiation of archaea are primarily through anaerobic carbon and hydrogen cycling.« less
Quantifying the kinetics and morphological changes of the fusion of spheroid building blocks.
Susienka, Michael J; Wilks, Benjamin T; Morgan, Jeffrey R
2016-10-10
Tissue fusion, whereby two or more spheroids coalesce, is a process that is fundamental to biofabrication. We have designed a quantitative, high-throughput platform to investigate the fusion of multicellular spheroids using agarose micro-molds. Spheroids of primary human chondrocytes (HCH) or human breast cancer cells (MCF-7) were self-assembled for 24 h and then brought together to form an array comprised of two spheroids (one doublet) per well. To quantify spheroid fusogenicity, we developed two assays: (1) an initial tack assay, defined as the minimum amount of time for two spheroids to form a mechanically stable tissue complex or doublet, and (2) a fusion assay, in which we defined and tracked key morphological parameters of the doublets as a function of time using wide-field fluorescence microscopy over a 24 h time-lapse. The initial tack of spheroid fusion was measured by inverting the micro-molds and centrifuging doublets at various time points to assess their connectedness. We found that the initial tack between two spheroids forms rapidly, with the majority of doublets remaining intact after centrifugation following just 30 min of fusion. Over the course of 24 h of fusion, several morphological changes occurred, which were quantified using a custom image analysis pipeline. End-to-end doublet lengths decreased over time, doublet widths decreased for chondrocytes and increased for MCF-7, contact lengths increased over time, and chondrocyte doublets exhibited higher intersphere angles at the end of fusion. We also assessed fusion by measuring the fluorescence intensity at the plane of fusion, which increased over time for both cell types. Interestingly, we observed that doublets moved and rotated in the micro-wells during fusion and this rotation was inhibited by ROCK inhibitor Y-27632 and myosin II inhibitor blebbistatin. Understanding and optimizing tissue fusion is essential for creating larger tissues, organs, or other structures using individual microtissues as building parts.
Self-Reacting Friction Stir Welding for Aluminum Alloy Circumferential Weld Applications
NASA Technical Reports Server (NTRS)
Bjorkman, Gerry; Cantrell, Mark; Carter, Robert
2003-01-01
Friction stir welding is an innovative weld process that continues to grow in use, in the commercial, defense, and space sectors. It produces high quality and high strength welds in aluminum alloys. The process consists of a rotating weld pin tool that plasticizes material through friction. The plasticized material is welded by applying a high weld forge force through the weld pin tool against the material during pin tool rotation. The high weld forge force is reacted against an anvil and a stout tool structure. A variation of friction stir welding currently being evaluated is self-reacting friction stir welding. Self-reacting friction stir welding incorporates two opposing shoulders on the crown and root sides of the weld joint. In self-reacting friction stir welding, the weld forge force is reacted against the crown shoulder portion of the weld pin tool by the root shoulder. This eliminates the need for a stout tooling structure to react the high weld forge force required in the typical friction stir weld process. Therefore, the self-reacting feature reduces tooling requirements and, therefore, process implementation costs. This makes the process attractive for aluminum alloy circumferential weld applications. To evaluate the application of self-reacting friction stir welding for aluminum alloy circumferential welding, a feasibility study was performed. The study consisted of performing a fourteen-foot diameter aluminum alloy circumferential demonstration weld using typical fusion weld tooling. To accomplish the demonstration weld, weld and tack weld development were performed and fourteen-foot diameter rings were fabricated. Weld development consisted of weld pin tool selection and the generation of a process map and envelope. Tack weld development evaluated gas tungsten arc welding and friction stir welding for tack welding rings together for circumferential welding. As a result of the study, a successful circumferential demonstration weld was produced leading the way for future circumferential weld implementation.
Yang, Yang; Qi, Si; Liu, Mengyue; Zhao, Yu; Li, Ning
2017-10-12
To compare the differences in the clinical therapeutic effects on chronic knee joint pain between the combination of the central-square needling technique of thumb-tack needles with the routine therapy of acupuncture, moxibustion and tuina and the routine therapy of acupuncture, moxibustion and tuina . One hundred and twenty patients of chronic knee joint pain were randomized into an observation group and a control group, 60 cases in each one. In the control group, the routine therapy of acupuncture, moxibustion and tuina was adopted. In the observation group, at the end of treatment with the routine therapy of acupuncture, moxibustion and tuina , the subcutaneous embedding therapy was followed with four thumb-tack needles at the sites 1 to 1.5 cm above, below and bilateral to the main point ( ashi point) separately, and the needles were retained for 24 h to 48 h. The treatment was given once every two days, three times a week, totally 6 times in two weeks; and the follow-up visit was done for 3 months in patients of the two groups. The visual analogue scale (VAS) score before and after each treatment, Lequesne index score before treatment and at the end of follow-up and the case numbers of proactive use of painkillers or receiving acupuncture treatment in the follow-up stage were compared and observed in the patients of the two groups. The VAS score was reduced gradually after treatment in the patients of the two groups. The differences were significant statistically after the second treatment as compared with those before the treatment in the two groups (all P <0.05), in which, the improvements in VAS scores after the third treatment in the observation group were more obvious than those in the control group (all P <0.05). At the end of follow-up visit, Lequesne index scores were all improved as compared with those before treatment in the two groups (both P <0.05) and the improvements were similar between the two groups ( P >0.05). In the follow-up stage, there were 0 case in the observation group and 9 cases in the control group in terms of proactive use of painkillers ( P <0.05). There were 5 cases in the observation group and 1 case in the control group receiving acupuncture treatment again ( P >0.05). The acupuncture scheme in assistance with the central-square needling technique of thumb-tack needles obviously relieves chronic knee joint pain, much better sustains the analgesic effects of acupuncture and improves patient compliance.
Curious Eyes: Individual Differences in Personality Predict Eye Movement Behavior in Scene-Viewing
ERIC Educational Resources Information Center
Risko, Evan F.; Anderson, Nicola C.; Lanthier, Sophie; Kingstone, Alan
2012-01-01
Visual exploration is driven by two main factors--the stimuli in our environment, and our own individual interests and intentions. Research investigating these two aspects of attentional guidance has focused almost exclusively on factors common across individuals. The present study took a different tack, and examined the role played by individual…
NCLB Cases Face Hurdles in the Courts
ERIC Educational Resources Information Center
Hendrie, Caroline
2005-01-01
When cobbling together the landmark No Child Left Behind Act in 2001, Congress quietly tacked on an unusual provision that says the law does not require states or school districts "to spend any funds or incur any costs not paid for under this act." Little noticed at the time and lifted directly from an earlier version of the law enacted…
DISTANCE VIEW, AUTOMOTIVE REPAIR SHOP ON LEFT AND UTILITY BUILDING ...
DISTANCE VIEW, AUTOMOTIVE REPAIR SHOP ON LEFT AND UTILITY BUILDING "B" ON RIGHT. HOSE WINDING SHED ADJACENT TO SHED-ROOFED ADDITION ON THE UTILITY BUILDING, BLM SEED SHED AND TACK SHED VISIBLE IN FAR DISTANCE. VIEW TO EAST, WITH SCALE. - Cedar City Automotive Repair Shop, 820 North Main Street, Cedar City, Iron County, UT
Sustainability with a Sane Tack
ERIC Educational Resources Information Center
Peterson, Dennis L.
2010-01-01
The author has been in education long enough to remember the bright orange stickers above every light switch reminding them to turn off the lights during the energy crisis of the 1970s. He remembers the TV commercial scanning piles of loose garbage along the highways, then panning out to show a tear rolling down the cheek of a Native American.…
Code of Federal Regulations, 2012 CFR
2012-01-01
... means such as nails, tacks, barbs, staples, adhesives, and which has one dimension greater than 1.83 m...”, with one dimension less than 1.83 m. (6 ft.) and a surface area less than 2.23 m.2 (24 sq. ft.), but intended to be assembled upon installation into assemblies which may have one dimension greater than 1.83 m...
5 Ways Sloppy Campuses Can Clean out Personal Data
ERIC Educational Resources Information Center
Read, Brock
2007-01-01
There was a time, not long ago, when students signed up to use Cornell University's rock-climbing wall by scribbling their Social Security numbers on a piece of paper tacked nearby. Steven J. Schuster remembers that era with a mixture of amusement and horror. An alarming number of personal records--many laced with Social Security numbers and other…
ERIC Educational Resources Information Center
Klenk, Jessicia A.; Pufpaff, Lisa A.
2011-01-01
Research on literacy instruction for students with multiple disabilities is limited. Empirical research on braille instruction for students with multiple disabilities that include congenital blindness is virtually nonexistent. This case study offers initial insight into possible methods of early braille literacy instruction for a student with…
Key acceptability attributes of orodispersible films.
Scarpa, Mariagiovanna; Paudel, Amrit; Kloprogge, Frank; Hsiao, Wen Kai; Bresciani, Massimo; Gaisford, Simon; Orlu, Mine
2018-04-01
The features rendering orodispersible films (ODFs) patient-centric formulations are widely discussed in the scientific literature. However there is a lack of research studies exploring ODF characteristics with a potential impact on end-user acceptability. The aim of this study was to identify the key ODF characteristics affecting end-user acceptability by developing in vitro test methods for the prediction of ODFs acceptability and correlate these formulation characteristics with the data obtained from a human panel study. Four drug-free single-polymer films were prepared by solvent casting. Solutions of poly(vinyl) alcohol (PVOH) 39 KDa (P1), PVOH 197 KDa (P2), carboxymethylcellulose (CMC) 395 KDa (C1), and CMC 725 KDa (C2) were prepared. Texture analysis and Dynamic Mechanical Analysis (DMA) were used to assess film tack. Petri dish and drop methods were used to assess disintegration time. A human panel of 24 healthy young adults was employed to identify end-user acceptability criteria of the four study film samples. Texture analysis data of ODF tack were not found to be in agreement with the in vivo perceived stickiness in the mouth. However, measurement of the area under the adhesive force curve obtained by DMA correlated with in vivo perceived stickiness data for all samples. The disintegration times obtained by drop method were more comparable to human panel data than the petri dish method. Hence DMA and drop methods proved to be promising methodologies for the prediction of the end-user acceptability. The type and molecular weight of the film-forming polymer had a strong influence on stickiness perception, whereas only polymeric molecular weight influenced perceived disintegration time. The human panel study showed that Participant Reported Outcomes (PROs) for the perceived stickiness in the mouth and disintegration time of test films received significantly different scores between samples, and thus were identified as the key attributes with the potential to affect the end-user acceptability. ODF stickiness and disintegration time should therefore be evaluated at an early stage of the drug product design. Copyright © 2018 Elsevier B.V. All rights reserved.
Nair, Jijeesh R; Porcarelli, Luca; Bella, Federico; Gerbaldi, Claudio
2015-06-17
Profoundly ion-conducting, self-standing, and tack-free ethylene oxide-based polymer electrolytes encompassing a room-temperature ionic liquid (RTIL) with specific amounts of lithium salt are successfully prepared via a rapid and easily upscalable process including a UV irradiation step. All prepared materials are thoroughly characterized in terms of their physical, chemical, and morphological properties and eventually galvanostatically cycled in lab-scale lithium batteries (LIBs) exploiting a novel direct polymerization procedure to get intimate electrode/electrolyte interfacial characteristics. The promising multipurpose characteristics of the newly elaborated materials are demonstrated by testing them in dye-sensitized solar cells (DSSCs), where the introduction of the iodine/iodide-based redox mediator in the polymer matrix assured the functioning of a lab-scale test cell with conversion efficiency exceeding 6% at 1 sun. The reported results enlighten the promising prospects of the material to be successfully implemented as stable, durable, and efficient electrolyte in next-generation energy conversion and storage devices.
Screening of high temperature adhesives for large area bonding
NASA Technical Reports Server (NTRS)
Stenersen, A. A.; Wykes, D. H.
1980-01-01
High temperature-resistant adhesive systems were screened for processability, mechanical and physical properties, operational capability at 589 K (600 F), and the ability to produce large area bonds of high quality in fabricating Space Shuttle components. The adhesives consisted primarily of polyimide systems, including FM34B-18, NR-150B2 (DuPont), PMR-15, LARC-13, LARC-160, Thermid 600, and AI-1130L (AMOCA). The processing studies included preparation of polyimide resins, fabrication of film adhesives, development of lay-up and cure procedures, fabrication of honeycomb sandwich panels, and fabrication of mid-plane bonded panels in joints up to 30.5 cm (12 in.) wide. The screening program included tests for tack and drape properties, reticulation and filleting characteristics, ability to produce void-free or low porosity bonds in mid-plane bonded panels, out-time stability, lap shear strength, climbing drum peel strength, and glass transition temperature (Tg). This paper describes the processing methods developed and the test results.
Handwriting and Gender: A Multi-Use Data Set
ERIC Educational Resources Information Center
Bradley, Sean
2015-01-01
Can individuals guess the gender of a writer based on a sample of his or her handwriting? We administer an electronic survey twice to the same individuals to find out. The resulting data set is interesting to students, rich enough to be amenable to a wide array of activities, and open to a variety of exploratory tacks for statistics students and…
Math and the Real World: Fun and Games. Teaching Math.
ERIC Educational Resources Information Center
May, Lola
1993-01-01
Describes three simple games that do not involve numbers and that can be used to teach children problem-solving strategies and math skills. The games are Tick-Tack-Toe; Jest, a game that uses a blocking strategy; and Nim, a game that uses a capturing strategy. All three games force students to plan ahead and calculate possible outcomes using…
21 CFR 74.3602 - D&C Violet No. 2.
Code of Federal Regulations, 2013 CFR
2013-04-01
... coloring absorbable meniscal tacks made from poly (L-lactic acid) at a level not to exceed 0.15 percent by... 21 Food and Drugs 1 2013-04-01 2013-04-01 false D&C Violet No. 2. 74.3602 Section 74.3602 Food and... ADDITIVES SUBJECT TO CERTIFICATION Medical Devices § 74.3602 D&C Violet No. 2. (a) Identity and...
21 CFR 74.3602 - D&C Violet No. 2.
Code of Federal Regulations, 2011 CFR
2011-04-01
... coloring absorbable meniscal tacks made from poly (L-lactic acid) at a level not to exceed 0.15 percent by... 21 Food and Drugs 1 2011-04-01 2011-04-01 false D&C Violet No. 2. 74.3602 Section 74.3602 Food and... ADDITIVES SUBJECT TO CERTIFICATION Medical Devices § 74.3602 D&C Violet No. 2. (a) Identity and...
21 CFR 74.3602 - D&C Violet No. 2.
Code of Federal Regulations, 2012 CFR
2012-04-01
... coloring absorbable meniscal tacks made from poly (L-lactic acid) at a level not to exceed 0.15 percent by... 21 Food and Drugs 1 2012-04-01 2012-04-01 false D&C Violet No. 2. 74.3602 Section 74.3602 Food and... ADDITIVES SUBJECT TO CERTIFICATION Medical Devices § 74.3602 D&C Violet No. 2. (a) Identity and...
21 CFR 74.3602 - D&C Violet No. 2.
Code of Federal Regulations, 2014 CFR
2014-04-01
... coloring absorbable meniscal tacks made from poly (L-lactic acid) at a level not to exceed 0.15 percent by... 21 Food and Drugs 1 2014-04-01 2014-04-01 false D&C Violet No. 2. 74.3602 Section 74.3602 Food and... ADDITIVES SUBJECT TO CERTIFICATION Medical Devices § 74.3602 D&C Violet No. 2. (a) Identity and...
21 CFR 74.3602 - D&C Violet No. 2.
Code of Federal Regulations, 2010 CFR
2010-04-01
... coloring absorbable meniscal tacks made from poly (L-lactic acid) at a level not to exceed 0.15 percent by... 21 Food and Drugs 1 2010-04-01 2010-04-01 false D&C Violet No. 2. 74.3602 Section 74.3602 Food and... ADDITIVES SUBJECT TO CERTIFICATION Medical Devices § 74.3602 D&C Violet No. 2. (a) Identity and...
ERIC Educational Resources Information Center
Baker, Dana Lee
2008-01-01
In issue definition in rights-based policy Canada stereotypically embraces a more positive, human rights-centered approach as compared with the American stereotype associated with the USA's more presumptively negative, civil rights-based tack. Since exclusionary infrastructures violate the core values of democratic governance, a failure to address…
Sticker Shock: State Funding Cuts Lead to Sharp Tuition Hikes at Florida Colleges
ERIC Educational Resources Information Center
Boulard, Garry
2011-01-01
The tuition increase at the University of Florida--one of 11 public universities in Florida to win the approval of the state's Board of Governors to tack a "tuition differential" of 7 percent onto an 8 percent increase already approved by the state legislature--comes in response to an unprecedented reduction of some $340 million in state…
Dual UV/thermally curable plastisols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, C.R.
1983-10-01
Photoactive, thermally curable plastisol compositions are made by mixing a thermoplastic (preferably poly(vinyl chloride)), a (meth)acrylate, a thermal initiator, a photoinitiator, and a conventional plasticizer. A short exposure of these compositions to UV results in a tack-free skin cure. Heating after UV irradiation gives simultaneous crosslinking and fusion. These dual UV/thermally curable plastisols are useful as adhesives, sealants, encapsulants, and in many other applications.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-19
... iron handle, 1 iron handle fragment, 1 iron bowl fragment, 2 iron keys, 1 iron hinge, 1 iron gun hammer, 2 iron gun pieces, 1 fish hook, 12 nails, 1 iron ring, 1 coffee mill, 1 possible iron file, 1 large iron tack, 4 iron rods, 3 unidentified iron fragments, 1 metal tube, 1 scissors fragment, 1 finial...
2016-10-03
dissolution, toughener dissolution and controlled chain-extension reactions in the continuous reactor high temperature “hot-zone” to advance conversion...rheology and tack. 2. Simultaneous MWCNT dispersion and stabilization in the continuous reactor low temperature “cold-zone” leading to an increased...Weight and Low Dispersity Polyacrylonitrile by Low Temperature RAFT Polymerization, Moskowitz, Jeremy, Abel, Brooks, McCormick, Charles, Wiggins
NASA Astrophysics Data System (ADS)
Zube, N.; Nimmo, F.; Jacobson, S. A.; Fischer, R. A.
2017-12-01
Short-lived isotopes, such as the decay of lithophile 182Hf into siderophile 182W with a half-life of 9 My, can provide constraints on the timescales of planetary core formation and accretion. Classical accretion scenarios have produced Hf-W isotopic outcomes like those measured presently on the Earth [2,3]. We examine Grand Tack accretion simulations [4,5] and determine the mantle equilibration conditions necessary to produce the observed tungsten isotopic anomaly. Additionally, we follow Hf-W evolution for pairs of bodies that experience a last giant impact fitting the conditions of Earth's Moon-forming collision. In this way, we determine the likelihood of producing the observed almost indistinguishable W isotope anomalies of the Earth and Moon mantles [6]. We model Hf-W evolution for growing planets in 141 N-body simulations during late accretion in the Grand Tack scenario. For each case, we vary the equilibration factor during collisions—the fraction of impactor core that experiences re-equilibration with the entire target mantle—in steps ranging from none (cores merging) to complete equilibration. For Earth-like and Mars-like surviving planets, we find that cases with a high equilibration factor (k > 0.8) and an intermediate (2:1 - 4:1) ratio of initial embryo mass to planetesimal mass were most frequently able to approximate the observed W measurements for Earth and Mars. The equilibration factor required is more restrictive than the one found for classical accretion scenarios [2,3] and may not be consistent with fluid-dynamical predictions [7]. Moons made of impactor material from Earth's last giant impact are only able to result in an Earth-Moon pair having sufficiently similar W anomalies with a likelihood of 8% or less across all simulations. This indicates that a scenario where the Moon isotopically equilibrated with the Earth's mantle after the impact [8] may be required to explain the measured values. [1] Kleine et al. 2009 [2] Nimmo et al. 2010 [3] Rudge et al. 2010 [4] Walsh et al. 2009 [5] Jacobson et al. 2014 [6] Touboul et al., 2007 [7] Deguen et al. 2014 [8] Pahlevan and Stevenson 2007
Ramazani Saadat Abadi, Ahmad
2014-01-01
Nitroglycerin (TNG) transdermal drug delivery systems (TDDSs) with different acrylic pressure-sensitive adhesives (PSAs) and chemical permeation enhancers (CPEs) were prepared. The effects of PSAs and CPEs types and concentrations on skin permeation and in vitro drug release from devices were evaluated using the dissolution method as well as the modified-jacketed Franz diffusion cells fitted with excised rat abdominal skin. It was demonstrated that the permeation rate or steady state flux (J ss) of the drug through the excised rat skin was dependent on the viscosity and type of acrylic PSA as well as the type of CPE. Among different acrylic PSAs, Duro-Tak 2516 and Duro-Tak 2054 showed the highest and Duro-Tak 2051 showed the lowest J ss. Among the various CPEs, propylene glycol and cetyl alcohol showed the highest and the lowest enhancement of the skin permeation of TNG, respectively. The adhesion properties of devices such as 180° peel strength and probe tack values were obtained. It was shown that increasing the concentration of CPE led to reduction in the adhesion property of PSA. Moreover, after optimization of the formulation, it was found that the use of 10% PG as a CPE and 25% nitroglycerin loading in Duro-Tak 2054 is an effective monolithic DIAP for the development of a transdermal therapeutic system for nitroglycerin. PMID:24511396
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2014-07-08
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-01-27
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-02-24
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Preparation and Characterization of Rivastigmine Transdermal Patch Based on Chitosan Microparticles.
Sadeghi, Mohsen; Ganji, Fariba; Taghizadeh, Seyyed Mojtaba; Daraei, Bahram
2016-01-01
Here we report a novel approach for preparation of a 6-day transdermal drug delivery system (TDDS) as treatment for mild to moderate Alzheimer's disease. The spray drying method was used to prepare microparticles containing the anti-Alzheimer drug, Rivastigmine, in combination with the natural polymer, chitosan, for transdermal drug delivery applications. The content of the drug was determined by High Performance Liquid Chromatography (HPLC) method which was validated as per FDA guidelines. The morphology and size range of the microparticles were determined; and the effect of drug concentration in the solution injected into the spray dryer on the particles characterizations was studied. The stability of Rivastigmine at high temperature was confirmed using FTIR analysis as well as a validate HPLC assay. The obtained results show that the drug was stable at high temperatures with 7 to 42% loading in the microparticles, and the higher drug concentrations of the solution injected into the spray dryer resulted in increase of the drug loading, surface drug and microparticles distortion. The TDDS containing the microparticles was also prepared with microparticle to dry adhesive ratios of 5, 10 and 15% using acrylic adhesive. Based on adhesion properties of the patches, gained from the probe tack and the peel adhesion 180° tests, and the 15% patch by having more drug content per unit area of the patch, and still having similar adhesion properties was compared to the microparticles-free patch of 5.1% Rivastigmine salt (equivalent to the drug content of the 15% patch) from the permeation point of view by using Franz cell diffusion over 6 days. The drug permeation rate from the microparticle-free patch was slower than the 15% microparticles patch, which is the result of crystallization of Rivastigmine salt in the acrylic adhesive. The 6-day-prepared TDDS can be considered as an alternative for one-week application of 6 Exelon patches.
A litmus test for exploitation: James Stacey Taylor's stakes and kidneys.
Kuntz, J R
2009-12-01
James Stacy Taylor advances a thorough argument for the legalization of markets in current (live) human kidneys. The market is seemly the most abhorrent type of market, a market where the least well-off sell part of their body to the most well off. Though rigorously defended overall, his arguments concerning exploitation are thin. I examine a number of prominent bioethicists' account of exploitation: most importantly, Ruth Sample's exploitation as degradation. I do so in the context of Taylor's argument, with the aim of buttressing Taylor's position that a regulated kidney market is morally allowable. I argue that Sample fails to provide normative grounds consistent with her claim that exploitation is wrong. I then reformulate her account for consistency and plausibility. Still, this seemingly more plausible view does not show that Taylor's regulated kidney market is prohibitively exploitative of impoverished persons. I tack into place one more piece of support for Taylor's conclusion. (wc. 148).
Air Force Civil Engineer, Volume 16, Number 3, 2008
2008-01-01
Uncontrolled condensation damages building components and equipment, causes excessive corrosion, and creates slipping hazards when allowed to puddle on the...structure that develops their economy, such as fish markets, meat markets, date processing plants, asphalt plants, and slaughterhouses. As this program...very often you get to see a flag going up anymore,” said Maj Daniel Tack, detachment commander, who had ducked inside from the pouring rain with
2016-08-01
Abstract Cyclic loading and weathering of reinforced concrete bridge decks cause corrosion of reinforcement steel , which leads to cracking, potholes...inforcement steel , on a deteriorated concrete bridge at Redstone Arsenal, AL. A pultruded deck system made by Zellcomp, Inc., was selected for...16 Figure 13. Form for grout haunch fabricated by tack welding steel strips to the top of the girder
Continuous Security Metrics for Prevalent Network Threats: Introduction and First Four Metrics
2012-05-22
cyber at- tack. Recently, high -prole successful attacks have been detected against the International Mon- etary Fund, Citibank, Lockheed Martin, Google...RSA Security, Sony, and Oak Ridge National Laboratory[13]. These and other attacks have heightened securing networks as a high priority for many...of high -severity vulnerabilities found by network vulnerability scanners (e.g., [40]) and the numbers or percentages of hosts that are are not
Early clinical outcomes following laparoscopic inguinal hernia repair.
Tolver, Mette Astrup
2013-07-01
Laparoscopic inguinal hernia repair (TAPP) has gained increasing popularity because of less post-operative pain and a shorter duration of convalescence compared with open hernia repair technique (Lichtenstein). However, investigation of duration of convalescence with non-restrictive recommendations, and a procedure-specific characterization of the early clinical outcomes after TAPP was lacking. Furthermore, optimization of the post-operative period with fibrin sealant versus tacks for fixation of mesh, and the glucocorticoid dexamethasone versus placebo needed to be investigated in randomized clinical trials. The objective of this PhD thesis was to characterize the early clinical outcomes after TAPP and optimize the post-operative period. The four studies included in this thesis have investigated duration of convalescence and procedure-specific post-operative pain and other early clinical outcomes after TAPP. Furthermore, it has been shown that fibrin sealant can improve the early post-operative period compared with tacks, while dexamethasone showed no advantages apart from reduced use of antiemetics compared with placebo. Based on these findings, and the existing knowledge, 3-5 days of convalescence should be expected when 1 day of convalescence is recommended and future studies should focus on reducing intraabdominal pain after TAPP. Fibrin sealant can optimize the early clinical outcomes but the risk of hernia recurrence and chronic pain needs to be evaluated. Dexamethasone should be investigated in higher doses.
Exploring microbial dark matter to resolve the deep archaeal ancestry of eukaryotes
Saw, Jimmy H.; Spang, Anja; Zaremba-Niedzwiedzka, Katarzyna; ...
2015-08-31
The origin of eukaryotes represents an enigmatic puzzle, which is still lacking a number of essential pieces. Whereas it is currently accepted that the process of eukaryogenesis involved an interplay between a host cell and an alphaproteobacterial endosymbiont, we currently lack detailed information regarding the identity and nature of these players. A number of studies have provided increasing support for the emergence of the eukaryotic host cell from within the archaeal domain of life, displaying a specific affiliation with the archaeal TACK superphylum. Recent studies have shown that genomic exploration of yet-uncultivated archaea, the so-called archaeal 'dark matter', is ablemore » to provide unprecedented insights into the process of eukaryogenesis. Here, we provide an overview of state-of-the-art cultivation-independent approaches, and demonstrate how these methods were used to obtain draft genome sequences of several novel members of the TACK superphylum, including Lokiarchaeum, two representatives of the Miscellaneous Crenarchaeotal Group (Bathyarchaeota), and a Korarchaeum-related lineage. In conclusion, the maturation of cultivation-independent genomics approaches, as well as future developments in next-generation sequencing technologies, will revolutionize our current view of microbial evolution and diversity, and provide profound new insights into the early evolution of life, including the enigmatic origin of the eukaryotic cell.« less
Exploring microbial dark matter to resolve the deep archaeal ancestry of eukaryotes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saw, Jimmy H.; Spang, Anja; Zaremba-Niedzwiedzka, Katarzyna
The origin of eukaryotes represents an enigmatic puzzle, which is still lacking a number of essential pieces. Whereas it is currently accepted that the process of eukaryogenesis involved an interplay between a host cell and an alphaproteobacterial endosymbiont, we currently lack detailed information regarding the identity and nature of these players. A number of studies have provided increasing support for the emergence of the eukaryotic host cell from within the archaeal domain of life, displaying a specific affiliation with the archaeal TACK superphylum. Recent studies have shown that genomic exploration of yet-uncultivated archaea, the so-called archaeal 'dark matter', is ablemore » to provide unprecedented insights into the process of eukaryogenesis. Here, we provide an overview of state-of-the-art cultivation-independent approaches, and demonstrate how these methods were used to obtain draft genome sequences of several novel members of the TACK superphylum, including Lokiarchaeum, two representatives of the Miscellaneous Crenarchaeotal Group (Bathyarchaeota), and a Korarchaeum-related lineage. In conclusion, the maturation of cultivation-independent genomics approaches, as well as future developments in next-generation sequencing technologies, will revolutionize our current view of microbial evolution and diversity, and provide profound new insights into the early evolution of life, including the enigmatic origin of the eukaryotic cell.« less
Methods and instruments for materials testing
NASA Technical Reports Server (NTRS)
Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)
2011-01-01
Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.
Logistical Support of the China Relief Expedition
1991-06-01
fruits and jelly .8 Additionally, hard bread (hard tack), rice, beans (preferred over rice by the soldiers), flour, sugar, coffee were issued. These...Sir Claude MacDonald to Captain John Jellicoe, Royal Navy. In the message, MacDonald asked for more troops immediately. Jellicoe relayed the message...to Rear Admiral Edward H. Seymour, Royal Navy, who immediately, in concert with the allies, began to land naval forces to increase the size of the
General engineering specifications for 6000 tpd SRC-I Demonstration Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains specifications for architectural features of buildings for the SRC-1 Demonstration Plant: skylights, ventilators, sealants, doors, mirrors, furring and lathing, gypsum plaster, lightweight plaster, wallboard, ceramic tile, acoustic ceiling systems, resilient flooring, carpeting, brick flooring, architectural painting, vinyl wall covering, chalkboards, tackboards, toilets, access flooring, lockers, partitions, washroom accessories, unit kitchens, dock levels, seals, shelters, custom casework, auditorium seats, drapery tacks, prefabricated buildings, stairs, elevators, shelves, etc. (LTN).
CDA hones its marketing message.
Jones, D G
1998-07-01
This article discusses the many tacks CDA has taken with its marketing campaigns over the years. The keys to success have been reasonable goals and sufficient funds to make an impact. The current campaign, while underfunded due to budget constraints, carries on the successful theme of positioning CDA and its member dentists as the trusted sources of dental information for consumers, legislators, and health care decision-makers. An accompanying article discusses the proposed ADA national marketing campaign.
Guaranteeing Spoof-Resilient Multi-Robot Networks
2016-02-12
key-distribution. Our core contribution is a novel al- gorithm implemented on commercial Wi - Fi radios that can “sense” spoofers using the physics of...encrypted key exchange, but rather a commercial Wi - Fi card and software to implement our so- lution. Our virtual sensor leverages the rich physical...cheap commodity Wi - Fi radios, unlike hardware-based solutions [46, 48]. (3) It is robust to client mobility and power-scaling at- tacks. Finally, our
Hazing in the U.S. Armed Forces: Recommendations for Hazing Prevention Policy and Practice
2015-01-01
playing abusive tricks; threatening or oering violence or bodily harm to another; striking; branding; tattooing; shav- ing; greasing; painting...or bodily harm to another; striking; branding; tattooing; shav- ing; greasing; painting; “pinning,” “tacking on,” “blood wings”; or forcing or...particular issue for hazing denitions that address psychological, mental, or emotional harm. Specically, as one of the most thorough previous reviews of
Atmospheric Probe Model: Construction and Wind Tunnel Tests
NASA Technical Reports Server (NTRS)
Vogel, Jerald M.
1998-01-01
The material contained in this document represents a summary of the results of a low speed wind tunnel test program to determine the performance of an atmospheric probe at low speed. The probe configuration tested consists of a 2/3 scale model constructed from a combination of hard maple wood and aluminum stock. The model design includes approximately 130 surface static pressure taps. Additional hardware incorporated in the baseline model provides a mechanism for simulating external and internal trailing edge split flaps for probe flow control. Test matrix parameters include probe side slip angle, external/internal split flap deflection angle, and trip strip applications. Test output database includes surface pressure distributions on both inner and outer annular wings and probe center line velocity distributions from forward probe to aft probe locations.
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
Leveraging Peacekeeping Partners: African Continental Progress One Sub-Region at a Time
2012-11-01
mass atrocities, the members of ECOWAS were effectively forced to shift their security stance from conflict management to conflict prevention. 8 In...tack with regards to their role in conflict management across the continent. Following the formation of the AU in the early 2000’s, the AU’s new...Washington, DC: GPO, June 2012). 2 Ibid., 2. 3 Williams, Paul D, “The African Union’s Conflict Management Capabilities,” Council on Foreign
Nanotechnology-Enhanced Lubricants for RF MEMS Switches
2011-03-01
and have greater capabilities. 2.1. Problem Background The Air Force employs numerous communication links between space -borne assets, airborne...beyond 10B of rated cold-switched life, such as high-value space -borne assets with 12+ year horizons to deployment. Warm-switched operation refers to...lids for 5 min. at 300W in oxygen 5. Stud bump substrates using a gold- silver alloy wire bonder – packages may be stored 6. Tack seal pre-form to lid
Air & Space Power Journal. Volume 26, Number 3, May-June 2012
2012-06-01
strategic interest worldwide, mak- ing air and space power all the more relevant. The ability to reach any point in the world through the air and outer...States and many militaries around the world divide warfare into three levels: strategic, operational, and tactical. Most people con- ceive of the...at- tacks, strikes against the center of gravity, and the element of surprise. The operational level of war has evolved significantly since World War
Code of Federal Regulations, 2012 CFR
2012-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Taghizadeh, Seyed Mojtaba; Soroushnia, Arezou; Mirzadeh, Hamid; Barikani, Mehdi
2009-04-01
In this study, the influence of the ratio of silicone (Si) to acrylic pressure-sensitive adhesive (PSA), polyvinyl pyrrolidone (PVP), and lauryl alcohol (LA) % (wt/wt) on the properties of a drug in adhesive patch containing 4% (wt/wt) fentanyl as model drug was evaluated. The dependent variables selected were drug solubility, in vitro drug release in the platforms as well as adhesion properties including peel strength and tack value. By using the central composite design of Design Expert software, it was found that the effect of each factor was different, yet all had influenced dependent variables significantly (p < .05). Quadratic model generated for various response variables using backward regression analysis was found to be statistically significant (p < .05). It was deduced that the presence of PVP and Si displayed similar trends on drug solubility and release. Each role played by Si with LA and PVP in release rate was separately investigated, and it was found that the presence of PVP and LA in lowering the amount of drug released was more dominant compared with that of Si. The release patterns at the early and later stages follow the Higuchi and semiempirical models, respectively. Effect of PVP as well as Si and LA were similar on tack value. The influence of LA compared to peeling characteristics of Si system was more pronounced.
Solar System Evolution through Planetesmial Collisions
NASA Astrophysics Data System (ADS)
Trierweiler, Isabella; Laughlin, Greg
2018-01-01
Understanding planet formation is crucial to unraveling the history of our Solar System. Refining our theory of planet formation has become particularly important as the discovery of exoplanet systems through missions like Kepler have indicated that our system is incredibly unique. Compared to other systems around Sun-like stars, we are missing a significant amount of mass in the inner region of our solar system.A leading explanation for the low mass of the terrestrial planets is Jupiter’s Grand Tack. In this theory, the existence of the rocky planets is thought to be the result of the migration of Jupiter through the inner solar system. This migration could spark a collisional cascade of planetesimals, allowing planetesimals to drift inwards and shepherd an original set of massive planets into the Sun, thus explaining the absence of massive planets in our current system. The remnants of the planetesimals would them become the building blocks for a new generation of smaller, rocky planets.Using the N-body simulator REBOUND, we investigate the dynamics of the Grand Tack. We focus in particular on collisional cascades, which are thought to cause the inward planetesimal drift. We first modify the simulator to account for fragmentation outcomes in planetesimal collisions. Modeling disks of varying initial conditions, we then characterize the disk conditions needed to begin a cascade and shed light on the solar system’s dynamics just prior to the formation of the terrestrial planets.
Probe compensation in cylindrical near-field scanning: A novel simulation methodology
NASA Technical Reports Server (NTRS)
Hussein, Ziad A.; Rahmat-Samii, Yahya
1993-01-01
Probe pattern compensation is essential in near-field scanning geometry, where there is a great need to accurately know far-field patterns at wide angular range. This paper focuses on a novel formulation and computer simulation to determine the precise need for and effect of probe compensation in cylindrical near-field scanning. The methodology is applied to a linear test array antenna and the NASA scatterometer radar antenna. The formulation is based on representing the probe by its equivalent tangential magnetic currents. The interaction between the probe equivalent aperture currents and the test antenna fields is obtained with the application of a reciprocity theorem. This allows us to obtain the probe vector output pickup integral which is proportional to the amplitude and phase of the electric field induced in the probe aperture with respect to its position to the test antenna. The integral is evaluated for each probe position on the required sampling point on a cylindrical near-field surface enclosing the antenna. The use of a hypothetical circular-aperture probe with a different radius permits us to derive closed-form expressions for its far-field radiation patterns. These results, together with the probe vector output pickup, allow us to perform computer simulated synthetic measurements. The far-field patterns of the test antenna are formulated based on cylindrical wave expansions of both the probe and test antenna fields. In the limit as the probe radius becomes very small, the probe vector output is the direct response of the near-field at a point, and no probe compensation is needed. Useful results are generated to compare the far-field pattern of the test antenna constructed from the knowledge of the simulated near-field with and without probe pattern compensation and the exact results. These results are important since they clearly illustrate the angular range over which probe compensation is needed. It has been found that a probe with an aperture radius of 0.25(lambda), 0.5(lambda), and 1(lambda) needs a little probe compensation, if any, near the test antenna main beam. In addition, a probe with low directivity may provide a better signal-to-noise ratio than a highly directive one. This is evident in test antenna patterns without probe compensation at wide angles.
Failure analysis on false call probe pins of microprocessor test equipment
NASA Astrophysics Data System (ADS)
Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.
2017-09-01
A study has been conducted to investigate failure analysis on probe pins of test modules for microprocessor. The `health condition' of the probe pin is determined by the resistance value. A test module of 5V power supplied from Arduino UNO with "Four-wire Ohm measurement" method is implemented in this study to measure the resistance of the probe pins of a microprocessor. The probe pins from a scrapped computer motherboard is used as the test sample in this study. The functionality of the test module was validated with the pre-measurement experiment via VEE Pro software. Lastly, the experimental work have demonstrated that the implemented test module have the capability to identify the probe pin's `health condition' based on the measured resistance value.
Chapin, Kimberle C.; Blake, Patricia; Wilson, Claire D.
2002-01-01
Group A streptococcus (GAS) antigen testing has become a routine point-of-care (POC) test in acute care settings. Concern about performance parameters (PP) of these tests as well as inappropriate antibiotic use has resulted in various recommendations regarding diagnosis of GAS. There were two objectives in this study. The first was to evaluate the rapid GAS antigen test presently in use (Thermo BioStar, Boulder, Colo.) and the GAS Direct probe test (Gen-Probe, San Diego, Calif.) compared to culture. The second was to define the optimal use of these technologies in a large acute care pediatric clinic. A total of 520 consecutive pediatric patients presenting with symptoms of pharyngitis at any of three Lahey Clinic acute care facilities were evaluated. Pharyngeal specimens were collected using a double-swab collection device (Copan, Corona, Calif.). One swab was used for the antigen test, the second was used for the probe test, and the pledget was placed in the collection device for culture on 5% sheep blood agar, incubated for 48 h anaerobically, and subsequently placed in Todd-Hewitt broth. After discrepant analysis, sensitivity, specificity, and positive and negative predictive values were as follows: 94.8, 100, 100, and 96.9% for the probe test and 86.1, 97.1, 93.7, and 93.4% for the antigen test, respectively. Sensitivity using an enhanced culture technique was 99.4% (163 of 164). False-positive (FP) antigen results were often seen from patients previously diagnosed and/or treated for GAS. No FP results were seen with the probe test. Colony counts for the false-negative (FN) antigen tests were higher than those for the FN probe tests. Compared to culture and DNA probe, the rapid antigen test (RAT) offered a result at the time of the patient's visit, with acceptable PP when prevalence of disease is high. Follow-up testing with the RAT of GAS patients who previously tested as positive should be avoided due to increased FP results. The probe test was comparable to culture in performance. Results indicate the probe test can be used as the primary test or as a backup to negative antigen tests. The probe test offers the advantage over culture of same-day reporting of a final result but, in contrast to a POC test, necessitates follow-up communication to the patient. Preliminary data show the specificity of the probe test to be greater than that of the RAT for patients previously diagnosed with GAS. PMID:12409399
Test module development to detect the flase call probe pins on microeprocessor test equipment
NASA Astrophysics Data System (ADS)
Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.
2017-09-01
Probe pins are useful for electrical testing of microelectronic components, printed circuit board assembly (PCBA), microprocessors and other electronic devices due to it provides the conductivity test based on specific device circuit design. During the repeatable test runs, the load of test modules, contact failures and the current conductivity induces layer wear off all the tip of probe pins contact. Contamination will be build-up on probe pins and increased contact resistivity which results of cost loss and time loss for rectifying programs, rectifying testers and exchanging new probe pins. In this study, a resistivity approach will be developed to provide "Testing of Test Probes". The test module based on "Four-wire Ohm measurement" method with two alternative ways of applying power supply, that are 9V from a single power supply and 5V from Arduino UNO power supply were demonstrated to measure the small resistance value of microprocessor probe pin. A microcontroller with VEE Pro software was used to record the measurement data. The accuracy of both test modules were calibrated under different temperature conditions and result shows that 9V from a single power supply test module has higher measurement accuracy.
2013-01-01
it to exist for ever among those who come after us. We are merely acting in accordance with it, and we know that you or anybody else with the same...of history’s 3 4 Nava l Wa r C o l l e g e r e v I e W course.16 Moreover, unexpected second- and third-order effects add to the dif- ficulty...a defensive measure , the athenians at- tacked their own ally Potidaea, which they believed was too closely connected to Corinth, which was its mother
National Strategy for Countering Biological Threats: Diplomacy and International Programs
2010-03-18
for the use of the Committee on Foreign Affairs ( Available via the World Wide Web: http://www.foreignaffairs.house.gov/ VerDate 0ct 09 2002 17:38 Jun...weapons are more likely to be acquired and used by terrorist groups than nuclear weapons. Al- though I might add that it is my belief that bioweapons...acts decisively and with great urgency, it is more likely than not that a weapon of mass destruction would be used in a terrorist at- tack somewhere in
Analysis of eye-tracking experiments performed on a Tobii T60
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banks, David C
2008-01-01
Commercial eye-gaze trackers have the potential to be an important tool for quantifying the benefits of new visualization techniques. The expense of such trackers has made their use relatively infrequent in visualization studies. As such, it is difficult for researchers to compare multiple devices obtaining several demonstration models is impractical in cost and time, and quantitative measures from real-world use are not readily available. In this paper, we present a sample protocol to determine the accuracy of a gaze-tacking device.
High Frontier: The Journal for Space & Missile Professionals. Volume 2, Number 4, August 2006
2006-08-01
among nations. With the information revolution, globalization has sped economic disparity and rapid cultural changes that have forced the United States...at every level to react to any Chinese move that puts targets from economic targets to military forces at risk of at- tack.12 The United States...Support Program (DSP) has been a model of war-fight- ing effectiveness for decades and exceeded all expectations, but its life span is not infinite. As
Herr, Yeek; Kwon, Young-Hyuk; Kim, Seong-Hun; Kim, Eun-Cheol
2014-01-01
This prospective randomized split-mouth study was performed to examine the effects of absorbable collagen membrane (ACM) application in augmented corticotomy using deproteinized bovine bone mineral (DBBM), during orthodontic buccal tipping movement in the dog. After buccal circumscribing corticotomy and DBBM grafting into the decorticated area, flaps were repositioned and sutured on control sides. ACM was overlaid and secured with membrane tacks, on test sides only, and the flaps were repositioned and sutured. Closed coil springs were used to apply 200 g orthodontic force in the buccolingual direction on the second and third premolars, immediately after primary flap closure. The buccal tipping angles were 31.19 ± 14.60° and 28.12 ± 11.48° on the control and test sides, respectively. A mean of 79.5 ± 16.0% of the buccal bone wall was replaced by new bone on the control side, and on the test side 78.9 ± 19.5% was replaced. ACM application promoted an even bone surface. In conclusion, ACM application in augmented corticotomy using DBBM might stimulate periodontal tissue reestablishment, which is useful for rapid orthodontic treatment or guided bone regeneration. In particular, ACM could control the formation of mesenchymal matrix, facilitating an even bone surface. PMID:25276824
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, K.C.; Noel, D.; Hechler, J.-J.
Samples of Narmco Rigidite 5208/WC3000 carbon-epoxy composite prepreg were exposed to ambient temperature and 50 percent relative humidity for different periods up to 66 days. The aging has a significant effect on prepreg physical properties such as tack, volatiles content, and gel time. A set of four-ply laminates made from aged prepreg was subjected to tensile testing, ultrasonic inspection, and optothermal inspection. No relationship could be discerned between laminate properties and prepreg aging time. However, variations in panel homogeneity were observed, and these correlated with thermal diffusivity and tensile modulus measurements, but not with ultimate tensile strength or elongation. Amore » set of six-ply laminates was used to measure compressive properties, interlaminar shear strength, and physical properties. These panels also showed variations in porosity, again unrelated to aging, but in addition, the fiber-resin ratio was observed to decrease with aging time. Both factors were found to affect mechanical properties. The implications concerning the importance of monitoring the aging by physicochemical methods are discussed. 30 refs.« less
Casanova, I; Diaz, A; Pinto, S; de Carvalho, M
2014-04-01
The technique of threshold tracking to test axonal excitability gives information about nodal and internodal ion channel function. We aimed to investigate variability of the motor excitability measurements in healthy controls, taking into account age, gender, body mass index (BMI) and small changes in skin temperature. We examined the left median nerve of 47 healthy controls using the automated threshold-tacking program, QTRAC. Statistical multiple regression analysis was applied to test relationship between nerve excitability measurements and subject variables. Comparisons between genders did not find any significant difference (P>0.2 for all comparisons). Multiple regression analysis showed that motor amplitude decreases with age and temperature, stimulus-response slope decreases with age and BMI, and that accommodation half-time decrease with age and temperature. The changes related to demographic features on TRONDE protocol parameters are small and less important than in conventional nerve conduction studies. Nonetheless, our results underscore the relevance of careful temperature control, and indicate that interpretation of stimulus-response slope and accommodation half-time should take into account age and BMI. In contrast, gender is not of major relevance to axonal threshold findings in motor nerves. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Groundwater recharge estimation in semi-arid zone: a study case from the region of Djelfa (Algeria)
NASA Astrophysics Data System (ADS)
Ali Rahmani, S. E.; Chibane, Brahim; Boucefiène, Abdelkader
2017-09-01
Deficiency of surface water resources in semi-arid area makes the groundwater the most preferred resource to assure population increased needs. In this research we are going to quantify the rate of groundwater recharge using new hybrid model tack in interest the annual rainfall and the average annual temperature and the geological characteristics of the area. This hybrid model was tested and calibrated using a chemical tracer method called Chloride mass balance method (CMB). This hybrid model is a combination between general hydrogeological model and a hydrological model. We have tested this model in an aquifer complex in the region of Djelfa (Algeria). Performance of this model was verified by five criteria [Nash, mean absolute error (MAE), Root mean square error (RMSE), the coefficient of determination and the arithmetic mean error (AME)]. These new approximations facilitate the groundwater management in semi-arid areas; this model is a perfection and amelioration of the model developed by Chibane et al. This model gives a very interesting result, with low uncertainty. A new recharge class diagram was established by our model to get rapidly and quickly the groundwater recharge value for any area in semi-arid region, using temperature and rainfall.
Kuwata, Tomoyuki; Takahashi, Hironori; Koibuchi, Harumi; Ichizuka, Kiyotake; Natori, Michiya; Matsubara, Shigeki
2016-10-01
To clarify the present status of human papillomavirus (HPV) contamination of transvaginal probes in Japan and propose a preventive method. This study was performed at three institutes: a tertiary center, secondary hospital, and primary facility. To identify contamination rates, probes were disinfected and covered with probe covers and condoms; the cover was changed for each patient. The probes were tested for HPV, and those with HPV detected were analyzed to identify the type of HPV. Next, nurses put on new gloves before covering the probe for each patient, and the probes were similarly tested for HPV. A total of 120 probes were tested, and HPV was detected from a total of five probes, a contamination rate of 4.2 % (5/120). HPV was detected in all three institutes. Importantly, high-risk HPV, i.e., HPV-52, 56, and 59, was detected. After the "glove change strategy" was implemented, HPV was not detected on any of 150 probes tested at any of the three institutions. In Japan, the HPV contamination rate of vaginal probes in routine practice was 4.2 %. There was no HPV contamination of probes after changing the gloves for cover exchange for each patient. This strategy may prevent HPV probe contamination.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Refinement of a thermal threshold probe to prevent burns.
Dixon, M J; Taylor, P M; Slingsby, L C; Murrell, J C
2016-02-01
Thermal threshold testing is commonly used for pain research. The stimulus may cause burning and merits prevention. Thermal probe modifications hypothesized to reduce burning were evaluated for practicality and effect. Studies were conducted on two humans and eight cats. Unmodified probe 0 was tested on two humans and promising modifications were also evaluated on cats. Probe 1 incorporated rapid cooling after threshold was reached: probe 1a used a Peltier system and probe 1b used water cooling. Probe 2 released skin contact immediately after threshold. Probe 3 (developed in the light of evidence of 'hot spots' in probe 0) incorporated reduced thermal mass and even heating across the skin contact area. Human skin was heated to 48℃ (6℃ above threshold) and the resulting burn was evaluated using area of injury and a simple descriptive scale (SDS). Probe 1a cooled the skin but required further heat dissipation, excessive power, was not 'fail-safe' and was inappropriate for animal mounting. Probe 1b caused less damage than no cooling (27 ± 13 and 38 ± 11 mm(2) respectively, P = 0.0266; median SDS 1.5 and 4 respectively, P = 0.0317) but was cumbersome. Probe 2 was unwieldy and was not evaluated further. Probe 3 produced even heating without blistering in humans. With probe 3 in cats, after opioid treatment, thermal threshold reached cut-out (55℃) on 24 occasions, exceeded 50℃ in a further 32 tests and exceeded 48℃ in the remainder. No skin damage was evident immediately after testing and mild hyperaemia in three cats at 2-3 days resolved rapidly. Probe 3 appeared to be suitable for thermal threshold testing. © The Author(s) 2015.
Alter, Gary J
2012-10-01
Weight gain and subsequent weight loss usually result in unsightly large fat deposition in the pubic areas along with ptosis of the fat pad and skin. Men also complain of burying of the penis and the woman complains of labia majora enlargement, both causing secondary sexual dysfunction, hygiene issues, discomfort, and aesthetic concerns. Even with weight loss, most of these deformities persist. The hidden (buried) penis is characterized by a lack of firm attachments between the Buck fascia surrounding the tunica albuginea of the corpora and the dartos fascia and skin. Successful treatment requires the penile skin and dartos fascia to be stabilized to the penile corporal bodies to make the penis one integrated unit. The method of surgery is usually to excise and lift excess pubic skin, eliminate the pubic fat without creating a significant pubic concavity, and stabilize the penile skin to the corporal bodies with tacking sutures dorsally and ventrally. If inadequate penile skin is present, scrotal flaps or skin grafts are used to cover the penis. Treatment of the mons pubis requires similar pubic lifting, fat excision, and pubic tacking. Labia majora reduction requires skin and usually fat excision. Results are excellent with the use of these techniques. Pubic contouring after massive weight loss in men and women is very successful and safe if performed meticulously. Treatment improves self-esteem along with the associated physical and aesthetic deformities.
Exciting an Initially Cold Asteroid Belt Through a Planetary Instability
NASA Astrophysics Data System (ADS)
Deienno, Rogerio; Izidoro, Andre; Morbidelli, Alessandro; Gomes, Rodney; Nesvorny, David; Raymond, Sean N.
2018-04-01
The main asteroid belt (MB) is low in mass but dynamically excited, with much larger eccentricities and inclinations than the planets. In recent years, the Grand Tack model has been the predominant model capable of reconciling the formation of the terrestrial planets with a depleted but excited MB. Despite this success, the Grand Tack is still not generally accepted because of uncertainties in orbital migration. It was recently proposed that chaotic early evolution of Jupiter and Saturn could excite the initially cold MB. However, hydrodynamical simulations predict that the giant planets should generally emerge from the gas disk phase on orbits characterized by resonant and regular motion. Here we propose a new mechanism to excite the MB during the giant planets' ('Nice model') instability, which is expected to have included repeated close encounters between Jupiter and one or more ice giants ('Jumping Jupiter' -- JJ). We show that when Jupiter temporarily reaches a high enough level of excitation, both in eccentricity and inclination, it induces strong forced vectors of eccentricity and inclination within the MB region. Because during the JJ instability Jupiter's orbit 'jumps' around, forced vectors keep changing both in magnitude and phase throughout the whole MB region. The entire cold primordial MB can thus be excited as a natural outcome of the JJ instability. Furthermore, we show that the subsequent evolution of the Solar System is capable of reshaping the resultant MB to its present day orbital state, and that a strong mass depletion is always associated to the JJ instability phase.
Development of a subsurface gas flow probe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cutler, R.P.; Ballard, S.; Barker, G.T.
1997-04-01
This report describes a project to develop a flow probe to monitor gas movement in the vadose zone due to passive venting or active remediation efforts such as soil vapor extraction. 3-D and 1-D probes were designed, fabricated, tested in known flow fields under laboratory conditions, and field tested. The 3-D pores were based on technology developed for ground water flow monitoring. The probes gave excellent agreement with measured air velocities in the laboratory tests. Data processing software developed for ground water flow probes was modified for use with air flow, and to accommodate various probe designs. Modifications were mademore » to decrease the cost of the probes, including developing a downhole multiplexer. Modeling indicated problems with flow channeling due to the mode of deployment. Additional testing was conducted and modifications were made to the probe and to the deployment methods. The probes were deployed at three test sites: a large outdoor test tank, a brief vapor extraction test at the Chemical Waste landfill, and at an active remediation site at a local gas station. The data from the field tests varied markedly from the laboratory test data. All of the major events such as vapor extraction system turn on and turn off, as well as changes in the flow rate, could be seen in the data. However, there were long term trends in the data which were much larger than the velocity signals, which made it difficult to determine accurate air velocities. These long term trends may be due to changes in soil moisture content and seasonal ground temperature variations.« less
Test probe for surface mounted leadless chip carrier
Meyer, Kerry L.; Topolewski, John
1989-05-23
A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.
Test probe for surface mounted leadless chip carrier
Meyer, K.L.; Topolewski, J.
1987-10-02
A test probe for a surface mounted leadless chip carrier is disclosed. The probe includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe. 1 fig.
Iodine Plasma Species Measurements in a Hall Effect Thruster Plume
2013-05-01
with an ExB probe , an electrostatic analyzer (ESA), and a combined ESA/ExB probe . The distribution of xenon ions was also measured. Multiply charge...of iodine ions was measured with an ExB probe , an electrostatic analyzer (ESA), and a combined ESA/ExB probe . • Results: – Multiply charged species...Test Hardware – Vacuum test facility (6’ diameter) – Faraday probe (MIT) – ESA, ExB, ESA/ExB Probes (Plasma Controls) – Rotary probe arm (about
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
NASA Astrophysics Data System (ADS)
Park, Jun-Hyub; Shin, Myung-Soo
2011-09-01
This paper describes the results of tensile tests for a beryllium-copper (BeCu) alloy thin film and the application of the results to the design of a probe. The copper alloy films were fabricated by electroplating. To obtain the tensile characteristics of the film, the dog-bone type specimen was fabricated by the etching method. The tensile tests were performed with the specimen using a test machine developed by the authors. The BeCu alloy has an elastic modulus of 119 GPa and the 0.2% offset yield and ultimate tensile strengths of 1078 MPa and 1108 MPa, respectively. The design and manufacture of a smaller probe require higher pad density and smaller pad-pitch chips. It should be effective in high-frequency testing. For the design of a new micro-probe, we investigated several design parameters that may cause problems, such as the contact force and life, using the tensile properties and the design of experiment method in conjunction with finite element analysis. The optimal dimensions of the probe were found using the response surface method. The probe with optimal dimensions was manufactured by a precision press process. It was verified that the manufactured probe satisfied the life, the contact force and the over drive through the compression tests and the life tests of the probes.
Test Sequence Priming in Recognition Memory
ERIC Educational Resources Information Center
Johns, Elizabeth E.; Mewhort, D. J. K.
2009-01-01
The authors examined priming within the test sequence in 3 recognition memory experiments. A probe primed its successor whenever both probes shared a feature with the same studied item ("interjacent priming"), indicating that the study item like the probe is central to the decision. Interjacent priming occurred even when the 2 probes did…
Wojcik, Thaddeus A.
1978-01-01
Two abutting members are locked together by reaming a hole entirely through one member and at least partly through the other, machining a circular groove in each through hole just below the surface of the member, press fitting a dowel pin having a thin wall extension on at least one end thereof into the hole in both members, a thin wall extension extending into each through hole, crimping or snapping the thin wall extension into the grooves to positively lock the dowel pin in place and, if necessary, tack welding the end of the thin-wall extension in place.
CTC Sentinel. Volume 3, Number 10, October 2010
2010-10-01
praises of 1 Ayman al-Zawahiri, “al-Badil huwa al-da‘wa wa-al- jihad,” Minbar al-Tawhid wa-al-Jihad, undated, available at www.tawhed.ws/r? i =8vp6jsjy...inter- view with al-Sahab, conducted four years after the at- tacks of 9/11. The interview is available at www.tawhed. ws/r? i =f3rahg23. The Strengths and...4 The Role of Lashkar- i -Islam in Pakistan’s Khyber Agency By syed Manzar Abbas Zaidi 6 The Torkham Border Closure and Attacks on NATO Supply
World War II: A Chronology. December 1943
1943-12-01
an: RAF aircraft ə t tack Sir,u harbor, probably damaging buildings on quayside. 2, Italy : Units of lOth Corps make gains on M . Ca1:.ino...by 4 B-25’:::> :,hich start fires dmong shore .buildings. 8 Italy : Units of 46th Div capture Cocuruzzo, on SVJ side of M . Cainino; 56th Div rnoves...conjunction with Itali <:ms, seizes positions on lv.i:. ;Lungo. ·Forty’:’"f~fth . Di’v moves tow~rd M . Cb.vallo; French attack M . Pc:.:ntq.no
Improved haptic interface for colonoscopy simulation.
Woo, Hyun Soo; Kim, Woo Seok; Ahn, Woojin; Lee, Doo Yong; Yi, Sun Young
2007-01-01
This paper presents an improved haptic interface of the KAIST-Ewha colonoscopy simulator II. The haptic interface enables the distal portion of the colonoscope to be freely bent while guaranteeing enough workspace and reflective forces for colonoscopy simulation. Its force-torque sensor measures profiles of the user. Manipulation of the colonoscope tip is monitored by four deflection sensors, and triggers computation to render accurate graphic images corresponding to the angle knob rotation. Tack switches are attached on the valve-actuation buttons of the colonoscope to simulate air-injection or suction, and the corresponding deformation of the colon.
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
NASA Astrophysics Data System (ADS)
Winebrenner, D. P.; Elam, W. T.; Carpenter, M.; Kintner, P., III
2014-12-01
More numerous observations within and beneath ice sheets are needed to address a broad variety of important questions concerning ice sheets and climate. However, emplacement of instruments continues to be constrained by logistical burdens, especially in cold ice a kilometer or more thick. Electrically powered thermal melt probes are inherently logistically light and efficient, especially for reaching greater depths in colder ice. They therefore offer a means of addressing current measurement problems, but have been limited historically by a lack of technology for reliable operation at the necessary voltages and powers. Here we report field tests in Greenland of two new melt probes. We operated one probe at 2.2 kilowatts (kW) and 1050 volts (V), achieving a depth of 400 m in the ice in ~ 120 hours, without electrical failure. That depth is the second greatest achieved thus far with a thermal melt probe, exceeded only by one deployment to 1005 m in Greenland in 1968, which ended in an electrical failure. Our test run took place in two intervals separated by a year, with the probe frozen at 65 m depth during the interim, after which we re-established communication, unfroze the probe, and proceeded to the greater depth. During the second field test we operated a higher-power probe, initially at 2.5 kW and 1500 V and progressing to 4.5 kW and 2000 V. Initial data indicate that this probe achieved a descent rate of 8 m/hr, which if correct would be the fastest rate yet achieved for such probes. Moreover, we observed maintenance of vertical probe travel using pendulum steering throughout both tests, as well as autonomous descent without operator-intervention after launch. The latter suggests potential for crews of 1-2 to operate several melt probes concurrently. However, the higher power probe did suffer electrical failure of a heating element after 7 hours of operation at 2000 V (24 hours after the start of the test), contrary to expectations based on laboratory component and system testing. We are therefore revising the probe heaters using a newer but more development-intensive technology. With probe systems now validated in our tests, this will result in a reliable means to emplace instruments for studies of subglacial hydrology, ice dynamics, and possible subglacial ecologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitz, Roger William; Oh, Yunje
A heating assembly configured for use in mechanical testing at a scale of microns or less. The heating assembly includes a probe tip assembly configured for coupling with a transducer of the mechanical testing system. The probe tip assembly includes a probe tip heater system having a heating element, a probe tip coupled with the probe tip heater system, and a heater socket assembly. The heater socket assembly, in one example, includes a yoke and a heater interface that form a socket within the heater socket assembly. The probe tip heater system, coupled with the probe tip, is slidably receivedmore » and clamped within the socket.« less
Design and Flight Evaluation of a New Force-Based Flow Angle Probe
NASA Technical Reports Server (NTRS)
Corda, Stephen; Vachon, Michael Jacob
2006-01-01
A novel force-based flow angle probe was designed and flight tested on the NASA F-15B Research Testbed aircraft at NASA Dryden Flight Research Center. The prototype flow angle probe is a small, aerodynamic fin that has no moving parts. Forces on the prototype flow angle probe are measured with strain gages and correlated with the local flow angle. The flow angle probe may provide greater simplicity, greater robustness, and better access to flow measurements in confined areas relative to conventional moving vane-type flow angle probes. Flight test data were obtained at subsonic, transonic, and supersonic Mach numbers to a maximum of Mach 1.70. Flight conditions included takeoff, landing, straight and level flight, flight at higher aircraft angles of attack, and flight at elevated g-loadings. Flight test maneuvers included angle-of-attack and angle-of-sideslip sweeps. The flow angle probe-derived flow angles are compared with those obtained with a conventional moving vane probe. The flight tests validated the feasibility of a force-based flow angle measurement system.
49 CFR 572.176 - Knees and knee impact test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...
49 CFR 572.176 - Knees and knee impact test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...
49 CFR 572.176 - Knees and knee impact test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...
The electrical performance of Ag Zn batteries for the Venus multi-probe mission
NASA Technical Reports Server (NTRS)
Palandati, C.
1975-01-01
An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.
Thermal Analysis of Small Re-Entry Probe
NASA Technical Reports Server (NTRS)
Agrawal, Parul; Prabhu, Dinesh K.; Chen, Y. K.
2012-01-01
The Small Probe Reentry Investigation for TPS Engineering (SPRITE) concept was developed at NASA Ames Research Center to facilitate arc-jet testing of a fully instrumented prototype probe at flight scale. Besides demonstrating the feasibility of testing a flight-scale model and the capability of an on-board data acquisition system, another objective for this project was to investigate the capability of simulation tools to predict thermal environments of the probe/test article and its interior. This paper focuses on finite-element thermal analyses of the SPRITE probe during the arcjet tests. Several iterations were performed during the early design phase to provide critical design parameters and guidelines for testing. The thermal effects of ablation and pyrolysis were incorporated into the final higher-fidelity modeling approach by coupling the finite-element analyses with a two-dimensional thermal protection materials response code. Model predictions show good agreement with thermocouple data obtained during the arcjet test.
Interpretation of the lime column penetration test
NASA Astrophysics Data System (ADS)
Liyanapathirana, D. S.; Kelly, R. B.
2010-06-01
Dry soil mix (DSM) columns are used to reduce the settlement and to improve the stability of embankments constructed on soft clays. During construction the shear strength of the columns needs to be confirmed for compliance with technical assumptions. A specialized blade shaped penetrometer known as the lime column probe, has been developed for testing DSM columns. This test can be carried out as a pull out resistance test (PORT) or a push in resistance test (PIRT). The test is considered to be more representative of average column shear strength than methods that test only a limited area of the column. Both PORT and PIRT tests require empirical correlations of measured resistance to an absolute measure of shear strength, in a similar manner to the cone penetration test. In this paper, finite element method is used to assess the probe factor, N, for the PORT test. Due to the large soil deformations around the probe, an Arbitrary Lagrangian Eulerian (ALE) based finite element formulation has been used. Variation of N with rigidity index and the friction at the probe-soil interface are investigated to establish a range for the probe factor.
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2012 CFR
2012-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2011 CFR
2011-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
Code of Federal Regulations, 2014 CFR
2014-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
Code of Federal Regulations, 2013 CFR
2013-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2011 CFR
2011-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2010 CFR
2010-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
Code of Federal Regulations, 2014 CFR
2014-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
Fabrication of Cantilever-Bump Type Si Probe Card
NASA Astrophysics Data System (ADS)
Park, Jeong-Yong; Lee, Dong-Seok; Kim, Dong-Kwon; Lee, Jong-Hyun
2000-12-01
Probe card is most important part in the test system which selects the good or bad chip of integrated circuit (IC) chips. Silicon vertical probe card is able to test multiple semiconductor chips simultaneously. We presented cantilever-bump type vertical probe card. It was fabricated by dry etching using RIE(reactive ion etching) technique and porous silicon micromachining using silicon direct bonded (SDB) wafer. Cantilevers and bumps were fabricated by isotropic etching using RIE@. 3-dimensional structures were formed by porous silicon micromachining technique using SDB wafer. Contact resistance of fabricated probe card was less than 2 Ω and its life time was more than 200,000 turns. The process used in this work is very simple and reproducible, which has good controllability in the tip dimension and spacing. It is expected that the fabricated probe card can reduce testing time, can promote productivity and enables burn-in test.
Hubbell, Joel M.; Sisson, James B.
2005-07-26
A method of inserting a tensiometer into a sample, comprises providing a drive probe configured to be engaged by direct push equipment; supporting a porous member from the drive probe; and driving the drive probe into the sample using a cone penetrometer. A tensiometer comprises a drive probe configured to be engaged by direct push equipment or a cone penetrometer; a porous member supported by the drive probe; and a pressure sensor in pressure sensing relation to the porous member.
Development of a Magnetic Attachment Method for Bionic Eye Applications.
Fox, Kate; Meffin, Hamish; Burns, Owen; Abbott, Carla J; Allen, Penelope J; Opie, Nicholas L; McGowan, Ceara; Yeoh, Jonathan; Ahnood, Arman; Luu, Chi D; Cicione, Rosemary; Saunders, Alexia L; McPhedran, Michelle; Cardamone, Lisa; Villalobos, Joel; Garrett, David J; Nayagam, David A X; Apollo, Nicholas V; Ganesan, Kumaravelu; Shivdasani, Mohit N; Stacey, Alastair; Escudie, Mathilde; Lichter, Samantha; Shepherd, Robert K; Prawer, Steven
2016-03-01
Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
RNA-Dependent Cysteine Biosynthesis in Bacteria and Archaea
Mukai, Takahito; Crnković, Ana; Umehara, Takuya; ...
2017-05-09
ABSTRACT The diversity of the genetic code systems used by microbes on earth is yet to be elucidated. It is known that certain methanogenic archaea employ an alternative system for cysteine (Cys) biosynthesis and encoding; tRNA Cysis first acylated with phosphoserine (Sep) byO-phosphoseryl-tRNA synthetase (SepRS) and then converted to Cys-tRNA Cysby Sep-tRNA:Cys-tRNA synthase (SepCysS). In this study, we searched all genomic and metagenomic protein sequence data in the Integrated Microbial Genomes (IMG) system and at the NCBI to reveal new clades of SepRS and SepCysS proteins belonging to diverse archaea in the four major groups (DPANN,Euryarchaeota, TACK, and Asgard) andmore » two groups of bacteria (“CandidatusParcubacteria” andChloroflexi). Bacterial SepRS and SepCysS charged bacterial tRNA Cysspecies with cysteinein vitro. Homologs of SepCysE, a scaffold protein facilitating SepRS-SepCysS complex assembly in Euryarchaeota class I methanogens, are found in a few groups of TACK and Asgard archaea, whereas the C-terminally truncated homologs exist fused or genetically coupled with diverse SepCysS species. Investigation of the selenocysteine (Sec)- and pyrrolysine (Pyl)-utilizing traits in SepRS-utilizing archaea and bacteria revealed that the archaea carrying full-length SepCysE employ Sec and that SepRS is often found in Pyl-utilizing archaea andChloroflexibacteria. We further discuss possible contributions of the SepRS-SepCysS system for sulfur assimilation, methanogenesis, and other metabolic processes requiring large amounts of iron-sulfur enzymes or Pyl-containing enzymes.« less
POSTMAN: Point of Sail Tacking for Maritime Autonomous Navigation
NASA Technical Reports Server (NTRS)
Huntsberger, Terrance L.; Reinhart, Felix
2012-01-01
Waves apply significant forces to small boats, in particular when such vessels are moving at a high speed in severe sea conditions. In addition, small high-speed boats run the risk of diving with the bow into the next wave crest during operations in the wavelengths and wave speeds that are typical for shallow water. In order to mitigate the issues of autonomous navigation in rough water, a hybrid controller called POSTMAN combines the concept of POS (point of sail) tack planning from the sailing domain with a standard PID (proportional-integral-derivative) controller that implements reliable target reaching for the motorized small boat control task. This is an embedded, adaptive software controller that uses look-ahead sensing in a closed loop method to perform path planning for safer navigation in rough waters. State-of-the-art controllers for small boats are based on complex models of the vessel's kinematics and dynamics. They enable the vessel to follow preplanned paths accurately and can theoretically control all of the small boat s six degrees of freedom. However, the problems of bow diving and other undesirable incidents are not addressed, and it is questionable if a six-DOF controller with basically a single actuator is possible at all. POSTMAN builds an adaptive capability into the controller based on sensed wave characteristics. This software will bring a muchneeded capability to unmanned small boats moving at high speeds. Previously, this class of boat was limited to wave heights of less than one meter in the sea states in which it could operate. POSTMAN is a major advance in autonomous safety for small maritime craft.
RNA-Dependent Cysteine Biosynthesis in Bacteria and Archaea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukai, Takahito; Crnković, Ana; Umehara, Takuya
ABSTRACT The diversity of the genetic code systems used by microbes on earth is yet to be elucidated. It is known that certain methanogenic archaea employ an alternative system for cysteine (Cys) biosynthesis and encoding; tRNA Cysis first acylated with phosphoserine (Sep) byO-phosphoseryl-tRNA synthetase (SepRS) and then converted to Cys-tRNA Cysby Sep-tRNA:Cys-tRNA synthase (SepCysS). In this study, we searched all genomic and metagenomic protein sequence data in the Integrated Microbial Genomes (IMG) system and at the NCBI to reveal new clades of SepRS and SepCysS proteins belonging to diverse archaea in the four major groups (DPANN,Euryarchaeota, TACK, and Asgard) andmore » two groups of bacteria (“CandidatusParcubacteria” andChloroflexi). Bacterial SepRS and SepCysS charged bacterial tRNA Cysspecies with cysteinein vitro. Homologs of SepCysE, a scaffold protein facilitating SepRS-SepCysS complex assembly in Euryarchaeota class I methanogens, are found in a few groups of TACK and Asgard archaea, whereas the C-terminally truncated homologs exist fused or genetically coupled with diverse SepCysS species. Investigation of the selenocysteine (Sec)- and pyrrolysine (Pyl)-utilizing traits in SepRS-utilizing archaea and bacteria revealed that the archaea carrying full-length SepCysE employ Sec and that SepRS is often found in Pyl-utilizing archaea andChloroflexibacteria. We further discuss possible contributions of the SepRS-SepCysS system for sulfur assimilation, methanogenesis, and other metabolic processes requiring large amounts of iron-sulfur enzymes or Pyl-containing enzymes.« less
Wind-Tunnel Tests of Seven Static-Pressure Probes at Transonic Speeds
NASA Technical Reports Server (NTRS)
Capone, Francis J.
1961-01-01
Wind-tunnel tests have been conducted to determine the errors of 3 seven static-pressure probes mounted very close to the nose of a body of revolution simulating a missile forebody. The tests were conducted at Mach numbers from 0.80 to 1.08 and at angles of attack from -1.7 deg to 8.4 deg. The test Reynolds number per foot varied from 3.35 x 10(exp 6) to 4.05 x 10(exp 6). For three 4-vane, gimbaled probes, the static-pressure errors remained constant throughout the test angle-of-attack range for all Mach numbers except 1.02. For two single-vane, self-rotating probes having two orifices at +/-37.5 deg. from the plane of symmetry on the lower surface of the probe body, the static-pressure error varied as much as 1.5 percent of free-stream static pressure through the test angle-of- attack range for all Mach numbers. For two fixed, cone-cylinder probes of short length and large diameter, the static-pressure error varied over the test angle-of-attack range at constant Mach numbers as much as 8 to 10 percent of free-stream static pressure.
Fluorescence In Situ Hybridization Probe Validation for Clinical Use.
Gu, Jun; Smith, Janice L; Dowling, Patricia K
2017-01-01
In this chapter, we provide a systematic overview of the published guidelines and validation procedures for fluorescence in situ hybridization (FISH) probes for clinical diagnostic use. FISH probes-which are classified as molecular probes or analyte-specific reagents (ASRs)-have been extensively used in vitro for both clinical diagnosis and research. Most commercially available FISH probes in the United States are strictly regulated by the U.S. Food and Drug Administration (FDA), the Centers for Disease Control and Prevention (CDC), the Centers for Medicare & Medicaid Services (CMS) the Clinical Laboratory Improvement Amendments (CLIA), and the College of American Pathologists (CAP). Although home-brewed FISH probes-defined as probes made in-house or acquired from a source that does not supply them to other laboratories-are not regulated by these agencies, they too must undergo the same individual validation process prior to clinical use as their commercial counterparts. Validation of a FISH probe involves initial validation and ongoing verification of the test system. Initial validation includes assessment of a probe's technical specifications, establishment of its standard operational procedure (SOP), determination of its clinical sensitivity and specificity, development of its cutoff, baseline, and normal reference ranges, gathering of analytics, confirmation of its applicability to a specific research or clinical setting, testing of samples with or without the abnormalities that the probe is meant to detect, staff training, and report building. Ongoing verification of the test system involves testing additional normal and abnormal samples using the same method employed during the initial validation of the probe.
Ho, Natalie; Shields, Robert W.; Cremer, Paul; Rodriguez, L. Leonardo
2018-01-01
A 36-year-old female with symptoms of orthostatic intolerance and syncope was diagnosed with vasovagal syncope on a tilt table test and with postural tachycardia syndrome (POTS) after a repeat tilt table test. However, an echocardiogram at our institution revealed obstructive cardiomyopathy without severe septal hypertrophy, with a striking increase in left ventricular outflow tract gradient from 7 mmHg at rest to 75 mmHg during Valsalva, with a septal thickness of only 1.3 cm. Cardiac MRI showed an apically displaced multiheaded posteromedial papillary muscle with suggestion of aberrant chordal attachments to the anterior mitral leaflet contributing to systolic anterior motion of the mitral valve. She underwent surgery with reorientation of the posterior medial papillary muscle head, resection of the tethering secondary chordae to the A1 segment of the mitral valve, chordal shortening and tacking of the chordae to the A1 and A2 segments of the mitral valve, and gentle septal myectomy. After surgery, she had significant improvement in her prior symptoms. To our knowledge, this is the first reported case of obstructive cardiomyopathy without severe septal hypertrophy with abnormalities in papillary muscle and chordal attachment, in a patient diagnosed with vasovagal syncope and POTS. PMID:29850268
Mayuga, Kenneth A; Ho, Natalie; Shields, Robert W; Cremer, Paul; Rodriguez, L Leonardo
2018-01-01
A 36-year-old female with symptoms of orthostatic intolerance and syncope was diagnosed with vasovagal syncope on a tilt table test and with postural tachycardia syndrome (POTS) after a repeat tilt table test. However, an echocardiogram at our institution revealed obstructive cardiomyopathy without severe septal hypertrophy, with a striking increase in left ventricular outflow tract gradient from 7 mmHg at rest to 75 mmHg during Valsalva, with a septal thickness of only 1.3 cm. Cardiac MRI showed an apically displaced multiheaded posteromedial papillary muscle with suggestion of aberrant chordal attachments to the anterior mitral leaflet contributing to systolic anterior motion of the mitral valve. She underwent surgery with reorientation of the posterior medial papillary muscle head, resection of the tethering secondary chordae to the A1 segment of the mitral valve, chordal shortening and tacking of the chordae to the A1 and A2 segments of the mitral valve, and gentle septal myectomy. After surgery, she had significant improvement in her prior symptoms. To our knowledge, this is the first reported case of obstructive cardiomyopathy without severe septal hypertrophy with abnormalities in papillary muscle and chordal attachment, in a patient diagnosed with vasovagal syncope and POTS.
Scheer, Clara; Mattioni Maturana, Felipe; Jansen, Petra
2018-05-07
In chronometric mental rotation tasks, sex differences are widely discussed. Most studies find men to be more skilled in mental rotation than women, which can be explained by the holistic strategy that they use to rotate stimuli. Women are believed to apply a piecemeal strategy. So far, there have been no studies investigating this phenomenon using eye-tacking methods in combination with electroencephalography (EEG) analysis: the present study compared behavioral responses, EEG activity, and eye movements of 15 men and 15 women while solving a three-dimensional chronometric mental rotation test. The behavioral analysis showed neither differences in reaction time nor in the accuracy rate between men and women. The EEG data showed a higher right activation on parietal electrodes for women and the eye-tracking results indicated a longer fixation in a higher number of areas of interest at 0° for women. Men and women are likely to possess different perceptual (visual search) and decision-making mechanisms, but similar mental rotation processes. Furthermore, men presented a longer visual search processing, characterized by the greater saccade latency of 0°-135°. Generally, this study could be considered a pilot study to investigate sex differences in mental rotation tasks while combining eye-tracking and EEG methods.
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
Code of Federal Regulations, 2014 CFR
2014-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
Code of Federal Regulations, 2012 CFR
2012-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2012 CFR
2012-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2013 CFR
2013-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2011 CFR
2011-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2014 CFR
2014-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
Code of Federal Regulations, 2011 CFR
2011-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
16 CFR § 1505.51 - Hot surfaces.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
Code of Federal Regulations, 2013 CFR
2013-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
Activation-deactivation of self-healing in supramolecular rubbers
NASA Astrophysics Data System (ADS)
Corte, Laurent; Maes, Florine; Montarnal, Damien; Cantournet, Sabine; Tournilhac, Francois; Leibler, Ludwik; Mines-Paristech Cnrs (Umr7633) Team; Espci-Paristech Cnrs (Umr7167) Team
2011-03-01
Self-healing materials have the ability to restore autonomously their structural integrity after damage. Such a remarkable property was obtained recently in supramolecular rubbers formed by a network of small molecules associated via hydrogen bonds. Here we explore this self-healing through an original tack experiment where two parts of supramolecular rubber are brought into contact and then separated. These experiments reveal that a strong self-healing ability is activated by damage even though the surfaces of a molded part are weakly self-adhesive. In our testing conditions, a five minute contact between crack faces is sufficient to recover most mechanical properties of the bulk while days are required to obtain such adhesion levels with melt-pressed surfaces. We show that the deactivation of this self-healing ability seems unexpectedly slow as compared to the predicted dynamics of supramolecular networks. Fracture faces stored apart at room temperature still self-heal after days but are fully deactivated within hours by annealing. Combining these results with microstructural observations gives us a deeper insight into the mechanisms involved in this self-healing process.
Comparative testing of pulse oximeter probes.
van Oostrom, Johannes H; Melker, Richard J
2004-05-01
The testing of pulse oximeter probes is generally limited to the integrity of the electrical circuit and does not include the optical properties of the probes. Few pulse oximeter testers evaluate the accuracy of both the monitor and the probe. We designed a study to compare the accuracy of nonproprietary probes (OSS Medical) designed for use with Nellcor, Datex-Ohmeda, and Criticare pulse oximeter monitors with that of their corresponding proprietary probes by using a commercial off-the-shelf pulse oximeter tester (Index). The Index pulse oximeter tester does include testing of the optical properties of the pulse oximeter probes. The pulse oximeter tester was given a controlled input that simulated acute apnea. Desaturation curves were automatically recorded from the pulse oximeter monitors with a data-collection computer. Comparisons between equivalent proprietary and nonproprietary probes were performed. Data were analyzed by using univariate and multivariate general linear model analysis. Five OSS Medical probe models were statistically better than the equivalent proprietary probes. The remainder of the probes were statistically similar. Comparative and simulation studies can have significant advantages over human studies because they are cost-effective, evaluate equipment in a clinically relevant scenario, and pose no risk to patients, but they are limited by the realism of the simulation. We studied the performance of pulse oximeter probes in a simulated environment. Our results show significant differences between some probes that affect the accuracy of measurement.
Probing Shells Against Buckling: A Nondestructive Technique for Laboratory Testing
NASA Astrophysics Data System (ADS)
Thompson, J. Michael T.; Hutchinson, John W.; Sieber, Jan
2017-12-01
This paper addresses testing of compressed structures, such as shells, that exhibit catastrophic buckling and notorious imperfection sensitivity. The central concept is the probing of a loaded structural specimen by a controlled lateral displacement to gain quantitative insight into its buckling behavior and to measure the energy barrier against buckling. This can provide design information about a structure’s stiffness and robustness against buckling in terms of energy and force landscapes. Developments in this area are relatively new but have proceeded rapidly with encouraging progress. Recent experimental tests on uniformly compressed spherical shells, and axially loaded cylinders, show excellent agreement with theoretical solutions. The probing technique could be a valuable experimental procedure for testing prototype structures, but before it can be used a range of potential problems must be examined and solved. The probing response is highly nonlinear and a variety of complications can occur. Here, we make a careful assessment of unexpected limit points and bifurcations, that could accompany probing, causing complications and possibly even collapse of a test specimen. First, a limit point in the probe displacement (associated with a cusp instability and fold) can result in dynamic buckling as probing progresses, as demonstrated in the buckling of a spherical shell under volume control. Second, various types of bifurcations which can occur on the probing path which result in the probing response becoming unstable are also discussed. To overcome these problems, we outline the extra controls over the entire structure that may be needed to stabilize the response.
Results and Conclusions from the NASA Isokinetic Total Water Content Probe 2009 IRT Test
NASA Technical Reports Server (NTRS)
Reehorst, Andrew; Brinker, David
2010-01-01
The NASA Glenn Research Center has developed and tested a Total Water Content Isokinetic Sampling Probe. Since, by its nature, it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument comprises the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Results and conclusions are presented from probe tests in the NASA Glenn Icing Research Tunnel (IRT) during January and February 2009. The use of reference probe heat and the control of air pressure in the water vapor measurement subsystem are discussed. Several run-time error sources were found to produce identifiable signatures that are presented and discussed. Some of the differences between measured Isokinetic Total Water Content Probe and IRT calibration seems to be caused by tunnel humidification and moisture/ice crystal blow around. Droplet size, airspeed, and liquid water content effects also appear to be present in the IRT calibration. Based upon test results, the authors provide recommendations for future Isokinetic Total Water Content Probe development.
Phase I Experimental Testing of a Generic Submarine Model in the DSTO Low Speed Wind Tunnel
2012-07-01
used during the tests , along with the test methodology . A sub-set of the data gathered is also presented and briefly discussed. Overall, the force...total pressure probe when positioned close to the model. 4. Results Selected results from the testing of the generic submarine model in the...Appendix B summaries the test conditions. 4.3.1 Smoke Generator and Probe An Aerotech smoke generator and probe were used for visualisation of
Imminent Engine Failure Probe Investigation.
probe signature determination, development of data recording techniques, accumulation of data during durability testing of T56 or TF41 engines and...any other opportunistic gas turbine engine test. The electrostatic probe demonstrated some capability to detect engine distress in TF41 and T56 engines
A computer-controlled apparatus for Seebeck inhomogeneity testing of sheathed thermocouples
NASA Technical Reports Server (NTRS)
Burkett, Cecil G., Jr.; Bauserman, Willard A., Jr.
1993-01-01
Mineral-insulated metal-sheathed (MIMS) thermocouple assemblies are used throughout industry and research facilities as a method of temperature measurement where requirements for either harsh environmental conditions exist, or where rigidity of the measurement probe is required. Seebeck inhomogeneity is the abnormal variation of the Seebeck coefficient from point to point in a material. It is not disclosed in conventional calibration. A standardized method of measuring thermoelectric inhomogeneity along the thermocouple probe length is not available. Therefore, calibration for sheathed probes normally does not include testing of probe inhomogeneity. The measurement accuracy would be severely impacted if significant inhomogeneity and a temperature gradient were present in the same region of the probe. A computer-controlled system for determining inhomogeneities was designed, fabricated, and tested. This system provides an accurate method for the identification of the location of inhomogeneity along the length of a sheathed thermocouple and for the quantification of the inhomogeneity. This paper will discuss the apparatus and procedure used to perform these tests and will present data showing tests performed on sheathed thermocouple probes.
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
Qiao, Yuchun; Shang, Jizhen; Li, Shuying; Feng, Luping; Jiang, Yao; Duan, Zhiqiang; Lv, Xiaoxia; Zhang, Chunxian; Yao, Tiantian; Dong, Zhichao; Zhang, Yu; Wang, Hua
2016-11-04
A fluorimetric Hg 2+ test strip has been developed using a lotus-inspired fabrication method for suppressing the "coffee stains" toward the uniform distribution of probe materials through creating a hydrophobic drying pattern for fast solvent evaporation. The test strips were first loaded with the model probes of fluorescent gold-silver nanoclusters and then dried in vacuum on the hydrophobic pattern. On the one hand, here, the hydrophobic constraining forces from the lotus surface-like pattern could control the exterior transport of dispersed nanoclusters on strips leading to the minimized "coffee stains". On the other hand, the vacuum-aided fast solvent evaporation could boost the interior Marangoni flow of probe materials on strips to expect the further improved probe distribution on strips. High aqueous stability and enhanced fluorescence of probes on test strips were realized by the hydrophilic treatment with amine-derivatized silicane. A test strips-based fluorimetry has thereby been developed for probing Hg 2+ ions in wastewater, showing the detection performances comparable to the classic instrumental analysis ones. Such a facile and efficient fabrication route for the bio-inspired suppression of "coffee stains" on test strips may expand the scope of applications of test strips-based "point-of-care" analysis methods or detection devices in the biomedical and environmental fields.
Rain Erosion Resistant AR Coating for ZnS Windows
1980-05-10
number) FLUR Windows, Rain Erosion Coatings; High Performance Aircrait in’- Coa t f ng De 1)os I t L on Tv c I n I (Iu es ; Me t ro Io gy ; TLest, i11g...developed for jinaging el"(rtrlo opt ical sensor systems intended for use on high performance a irer; Ia It s, ’ as F-4, F-15, F-16, A-10 J-18 and F-ill...for Forward Looking Infrared (FLIk) thermal imaging sensors such as those in- corporated in the PAVE TACK pod and the IR Maverick Missile. ’This
Pulsed GMAW Parameter Variation to Minimize Interference from Tack Welds
1987-05-01
14 ) * AREA 5 ) I"~ MN DECK MNDK- -’- ,r 1 2NDDECK 1 NS K IST PLATF 1ST PLATF - .4. 2NO...charges by craft. (7) Craft Burners/welders 16 Electricians 14 Pipefitters 14 Shipfitters 11 Sheetmetal 11 Laborers 5 Painters 4 Marine machinists 3 Other...17.1 1.0 0 13 250 25 15 .25 17.1 2.8 0 5 14 300 24 15 . 5 20.5 3.4 1.1 15 300 24 15 . 5 20.5 2.3 .8 16 300 24 15 . 5 20.5 5.1 . 5 6 17 300 24 15 .25
1947-02-21
refers to an airfoil section cenrposed of two parabolic arcs. £1 each case, the ving is con - sidered to be cut off in a direction parallel to the... pro - f:llo (fig. -(b) and appendix A, oquation (A?-))> The drag cooffl- clonts &ct\\ and ^caTT &?e obtained slmilurly by integrating along tho...appendix D. Bra» coefficient of swot -tack wlnfl at Mach number of 1.0. - Tho solution of the equations for c. fiven in appendix 3 shown tliat, for
The effect of tracking network configuration on GPS baseline estimates for the CASA Uno experiment
NASA Technical Reports Server (NTRS)
Wolf, S. Kornreich; Dixon, T. H.; Freymueller, J. T.
1990-01-01
The effect of the tracking network on long (greater than 100 km) GPS baseline estimates was estimated using various subsets of the global tracking network initiated by the first Central and South America (CASA Uno) experiment. It was found that best results could be obtained with a global tacking network consisting of three U.S. stations, two sites in the southwestern Pacific, and two sites in Europe. In comparison with smaller subsets, this global network improved the baseline repeatability, the resolution of carrier phase cycle ambiguities, and formal errors of the orbit estimates.
NASA Astrophysics Data System (ADS)
Chen, I.-H.; Horikawa, S.; Xi, J.; Wikle, H. C.; Barbaree, J. M.; Chin, B. A.
2017-05-01
Phage based magneto-elastic (ME) biosensors have been shown to be able to rapidly detect Salmonella in various food systems to serve food pathogen monitoring purposes. In this ME biosensor platform, the free-standing strip-shaped magneto-elastic sensor is the transducer and the phage probe that recognizes Salmonella in food serves as the bio-recognition element. According to Sorokulova et al. at 2005, a developed oligonucleotide probe E2 was reported to have high specificity to Salmonella enterica Typhimurium. In the report, the specificity tests were focused in most of Enterobacterace groups outside of Salmonella family. Here, to understand the specificity of phage E2 to different Salmonella enterica serotypes within Salmonella Family, we further tested the specificity of the phage probe to thirty-two Salmonella serotypes that were present in the major foodborne outbreaks during the past ten years (according to Centers for Disease Control and Prevention). The tests were conducted through an Enzyme linked Immunosorbent Assay (ELISA) format. This assay can mimic probe immobilized conditions on the magnetoelastic biosensor platform and also enable to study the binding specificity of oligonucleotide probes toward different Salmonella while avoiding phage/ sensor lot variations. Test results confirmed that this oligonucleotide probe E2 was high specific to Salmonella Typhimurium cells but showed cross reactivity to Salmonella Tennessee and four other serotypes among the thirty-two tested Salmonella serotypes.
Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis
Noble, Donald T.; Braymen, Steven D.; Anderson, Marvin S.
1996-10-01
A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point mad a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained.
Outer planet probe engineering model structural tests
NASA Technical Reports Server (NTRS)
Smittkamp, J. A.; Gustin, W. H.; Griffin, M. W.
1977-01-01
A series of proof of concept structural tests was performed on an engineering model of the Outer Planets Atmospheric Entry Probe. The tests consisted of pyrotechnic shock, dynamic and static loadings. The tests partially verified the structural concept.
Non-Invasive Blood Perfusion Measurements Using a Combined Temperature and Heat Flux Surface Probe
Ricketts, Patricia L.; Mudaliar, Ashvinikumar V.; Ellis, Brent E.; Pullins, Clay A.; Meyers, Leah A.; Lanz, Otto I.; Scott, Elaine P.; Diller, Thomas E.
2009-01-01
Non-invasive blood perfusion measurement systems have been developed and tested in a phantom tissue and an animal model. The probes use a small sensor with a laminated flat thermocouple to measure the heat transfer and temperature response to an arbitrary thermal event (convective or conductive) imposed on the tissue surface. Blood perfusion and thermal contact resistance are estimated by comparing heat flux data with a mathematical model of the tissue. The perfusion probes were evaluated for repeatability and sensitivity using both a phantom tissue test stand and exposed rat liver tests. Perfusion in the phantom tissue tests was varied by controlling the flow of water into the phantom tissue test section, and the perfusion in the exposed liver tests was varied by temporarily occluding blood flow through the portal vein. The phantom tissue tests indicated that the probes can be used to detect small changes in perfusion (0.005 ml/ml/s). The probes qualitatively tracked the changes in the perfusion of the liver model due to occlusion of the portal vein. PMID:19885372
Rate-dependent elastic hysteresis during the peeling of pressure sensitive adhesives.
Villey, Richard; Creton, Costantino; Cortet, Pierre-Philippe; Dalbe, Marie-Julie; Jet, Thomas; Saintyves, Baudouin; Santucci, Stéphane; Vanel, Loïc; Yarusso, David J; Ciccotti, Matteo
2015-05-07
The modelling of the adherence energy during peeling of Pressure Sensitive Adhesives (PSA) has received much attention since the 1950's, uncovering several factors that aim at explaining their high adherence on most substrates, such as the softness and strong viscoelastic behaviour of the adhesive, the low thickness of the adhesive layer and its confinement by a rigid backing. The more recent investigation of adhesives by probe-tack methods also revealed the importance of cavitation and stringing mechanisms during debonding, underlining the influence of large deformations and of the related non-linear response of the material, which also intervenes during peeling. Although a global modelling of the complex coupling of all these ingredients remains a formidable issue, we report here some key experiments and modelling arguments that should constitute an important step forward. We first measure a non-trivial dependence of the adherence energy on the loading geometry, namely through the influence of the peeling angle, which is found to be separable from the peeling velocity dependence. This is the first time to our knowledge that such adherence energy dependence on the peeling angle is systematically investigated and unambiguously demonstrated. Secondly, we reveal an independent strong influence of the large strain rheology of the adhesives on the adherence energy. We complete both measurements with a microscopic investigation of the debonding region. We discuss existing modellings in light of these measurements and of recent soft material mechanics arguments, to show that the adherence energy during peeling of PSA should not be associated to the propagation of an interfacial stress singularity. The relevant deformation mechanisms are actually located over the whole adhesive thickness, and the adherence energy during peeling of PSA should rather be associated to the energy loss by viscous friction and by rate-dependent elastic hysteresis.
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
Effects of Mach number on pitot-probe displacement in a turbulent boundary layer
NASA Technical Reports Server (NTRS)
Allen, J. M.
1974-01-01
Experimental pitot-probe-displacement data have been obtained in a turbulent boundary layer at a local free-stream Mach number of 4.63 and unit Reynolds number of 6.46 million meter. The results of this study were compared with lower Mach number results of previous studies. It was found that small probes showed displacement only, whereas the larger probes showed not only displacement but also distortion of the shape of the boundary-layer profile. The distortion pattern occurred lower in the boundary layer at the higher Mach number than at the the lower Mach number. The maximum distortion occurred when the center of the probe was about one probe diameter off the test surface. For probes in the wall contact position, the indicated Mach numbers were, for all probes tested, close to the true profile. Pitot-probe displacement was found to increase significantly with increasing Mach number.
NONDESTRUCTIVE EDDY CURRENT TESTING
Renken, C.J. Jr.
1961-05-23
An eddy current testing device is described for measuring metal continuity independent of probe-to-sample spacing. An inductance would test probe is made a leg of a variable impedance bridge and the bridge is balanced with the probe away from the sample. An a-c signal is applied across the input terminals of the bridge circuit. As the probe is brought into proximity with the metal sample, the resulting impedance change in the probe gives an output signal from the bridge whose phase angle is proportional to the sample continuity and amplitude is proportional to the probe-tosample spacing. The output signal from the bridge is applied to a compensating network where, responsive to amplitude changes from the bridge output signal, a constant phased voltage output is maintained when the sample is continuous regardless of probe-to-sample spacing. A phase meter calibrated to read changes in resistivity of the metal sample measures the phase shift between the output of the compensating network and the original a-c signal applied to the bridge.
Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis
Noble, D.T.; Braymen, S.D.; Anderson, M.S.
1996-10-01
A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point and a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained. 9 figs.
An Experimental Evaluation of the Performance of Two Combination Pitot Pressure Probes
NASA Technical Reports Server (NTRS)
Arend, David J.; Saunders, John D.
2009-01-01
Experimental tests have been completed which recorded the ability of two combination steady state and high response time varying Pitot probe designs to accurately measure steady stagnation pressure at a single location in a flow field. Tests were conducted of double-barreled and coannular Prati probes in a 3.5 in. diameter free jet probe calibration facility from Mach 0.1 to 0.9. Geometric symmetry and pitch (-40 deg to 40 deg) and yaw (0 deg to 40 deg) angle actuation were used to fully evaluate the probes. These tests revealed that the double-barreled configuration induced error in its steady state measurement at zero incidence that increased consistently with jet Mach number to 1.1 percent at Mach 0.9. For all Mach numbers, the double-barreled probe nulled at a pitch angle of approximately 7.0 deg and provided inconsistent measurements when yawed. The double-barreled probe provided adequate measurements via both its steady state and high response tubes (within +/- 0.15 percent accuracy) over unacceptable ranges of biased pitch and inconsistent yaw angles which varied with Mach number. By comparison, the coannular probe provided accurate measurements (at zero incidence) for all jet Mach numbers as well as over a flow angularity range which varied from +/- 26.0 deg at Mach 0.3 deg to +/- 14.0 deg at Mach 0.9. Based on these results, the Prati probe is established as the preferred design. Further experimental tests are recommended to document the frequency response characteristics of the Prati probe.
Addressable Inverter Matrix Tests Integrated-Circuit Wafer
NASA Technical Reports Server (NTRS)
Buehler, Martin G.
1988-01-01
Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.
Oligodeoxynucleotide Probes for Detecting Intact Cells
NASA Technical Reports Server (NTRS)
Rosson, Reinhardt A.; Maurina-Brunker, Julie; Langley, Kim; Pynnonen, Christine M.
2004-01-01
A rapid, sensitive test using chemiluminescent oligodeoxynucleotide probes has been developed for detecting, identifying, and enumerating intact cells. The test is intended especially for use in detecting and enumerating bacteria and yeasts in potable water. As in related tests that have been developed recently for similar purposes, the oligodeoxynucleotide probes used in this test are typically targeted at either singlecopy deoxyribonucleic acid (DNA) genes (such as virulence genes) or the multiple copies (10,000 to 50,000 copies per cell) of 16S ribosomal ribonucleic acids (rRNAs). Some of those tests involve radioisotope or fluorescent labeling of the probes for reporting hybridization of probes to target nucleic acids. Others of those tests involve labeling with enzymes plus the use of chemiluminescent or chromogenic substrates to report hybridization via color or the emission of light, respectively. The present test is of the last-mentioned type. The chemiluminescence in the present test can be detected easily with relatively simple instrumentation. In developing the present test, the hybridization approach was chosen because hybridization techniques are very specific. Hybridization detects stable, inheritable genetic targets within microorganisms. These targets are not dependent on products of gene expression that can vary with growth conditions or physiological states of organisms in test samples. Therefore, unique probes can be designed to detect and identify specific genera or species of bacteria or yeast (in terms of rRNA target sequences) or can be designed to detect and identify virulence genes (genomic target sequences). Because of the inherent specificity of this system, there are few problems of cross-reactivity. Hybridization tests are rapid, but hybridization tests now available commercially lack sensitivity; typically, between 10(exp 6) and 10(exp 7) cells of the target organism are needed to ensure a reliable test. Consequently, the numbers of target bacteria in samples are usually amplified by overnight pre-enrichment growth. These tests are usually performed in laboratories by skilled technicians. The present test was designed to overcome the shortcomings of the commercial hybridization tests. The figure summarizes the major steps of the test. It is important to emphasize that the hybridization process used in this test differs from that of other hybridization tests in that it does not extract target nucleic acids. This process is based on intact-cell hybridization (so-called in situ hybridization ), wherein the intact cells act as immobilizing agents. The cells are identified and enumerated by measuring the chemiluminescence emitted from alkaline phosphatase-probe (AP-probe) hybridization; the chemiluminescence is detected or measured by use of photographic film or a luminometer, respectively.
Qiao, Yuchun; Shang, Jizhen; Li, Shuying; Feng, Luping; Jiang, Yao; Duan, Zhiqiang; Lv, Xiaoxia; Zhang, Chunxian; Yao, Tiantian; Dong, Zhichao; Zhang, Yu; Wang, Hua
2016-01-01
A fluorimetric Hg2+ test strip has been developed using a lotus-inspired fabrication method for suppressing the “coffee stains” toward the uniform distribution of probe materials through creating a hydrophobic drying pattern for fast solvent evaporation. The test strips were first loaded with the model probes of fluorescent gold-silver nanoclusters and then dried in vacuum on the hydrophobic pattern. On the one hand, here, the hydrophobic constraining forces from the lotus surface-like pattern could control the exterior transport of dispersed nanoclusters on strips leading to the minimized “coffee stains”. On the other hand, the vacuum-aided fast solvent evaporation could boost the interior Marangoni flow of probe materials on strips to expect the further improved probe distribution on strips. High aqueous stability and enhanced fluorescence of probes on test strips were realized by the hydrophilic treatment with amine-derivatized silicane. A test strips-based fluorimetry has thereby been developed for probing Hg2+ ions in wastewater, showing the detection performances comparable to the classic instrumental analysis ones. Such a facile and efficient fabrication route for the bio-inspired suppression of “coffee stains” on test strips may expand the scope of applications of test strips-based “point-of-care” analysis methods or detection devices in the biomedical and environmental fields. PMID:27812040
Barker, Timothy Hugh; Howarth, Gordon Stanley; Whittaker, Alexandra Louise
2018-01-01
Extinction of learning is a common, yet under-reported limitation of judgment bias testing methods Repeated exposure to the ambiguous probe of a judgment bias paradigm encourages the animal to cease display of the required behaviours. However, there remains a need to repeatedly test animals to achieve statistical power. A delicate balance therefore needs to be struck between over- and under-exposure of the animals to the test conditions. This study presents the data of rats, a common animal subject of judgment bias testing. Rats were exposed to the ambiguous probe of a common, active-choice judgment bias test for 11 consecutive days. There was a significant increase in the latency to respond to the ambiguous probe following day 8, with no significant increase experienced for either the positive or less-positive probes. Following day 8 there was a significant increase in both optimistic and pessimistic latencies in response to the ambiguous probe. Therefore, repeated exposure to the ambiguous probe caused an increased latency in response even though optimistic interpretations were recorded. This implies that the use of response latency alone as a measure in judgment bias testing can falsely identify pessimism. Researchers should modify experimental design to include both choice and latency measures. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Lagen, Nicholas T.; Seiner, John M.
1990-01-01
The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.
Tran, Kim; Zajkowska, Marta; Lam, Vincent; Hawthorne, Wayne J.
2015-01-01
Background and Objectives: Despite the exponential increase in the use of laparoscopic inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, a growing number of patients are presenting with recurrent hernias after conventional anterior and laparoscopic repairs have failed. This study reports our experience with single-incision laparoscopic (SIL) intraperitoneal onlay mesh (IPOM) repair of these hernias. Methods: Patients referred with two or more recurrences of inguinal hernia underwent SIL-IPOM from November 1, 2009, to June 24, 2014. A 2.5-cm infraumbilical incision was made, and an SIL port was placed intraperitoneally. Modified dissection techniques were used: chopstick and inline dissection, 5.5-mm/52-cm/30° angled laparoscope, and conventional straight dissecting instruments. The peritoneum was incised above the pubic symphysis, and dissection was continued laterally and proximally, raising the inferior flap below the previous extraperitoneal mesh while reducing any direct, indirect, femoral, or cord lipoma before placement of antiadhesive mesh, which was fixed to the pubic ramus, as well as superiorly, with nonabsorbable tacks before the inferior border was fixed with fibrin sealant. The inferior peritoneal flap was then tacked back onto the mesh. Results: Nine male patients underwent SIL-IPOM. Their mean age was 53 years and mean body mass index was 26.8 kg/m2. Mean mesh size was 275 cm2. Mean operation time was 125 minutes, with a hospital stay of 1 day. The umbilical scar length was 23 mm at the 6-week follow-up. There were no intra-/postoperative complications, port-site hernias, chronic groin pain, or recurrence of the hernia during a mean follow-up of 24 months. Conclusion: Inguinal hernias recurring after two or more failed conventional anterior and laparoscopic repairs can be safely and efficiently treated with SIL-IPOM. PMID:25848186
Tran, Kim; Zajkowska, Marta; Lam, Vincent; Hawthorne, Wayne
2014-01-01
Introduction: Despite an exponential rise in laparoscopic surgery for inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, an increasing number of patients present with recurrent hernias after having failed anterior and laparoscopic repairs. This study reports our experience with single-incision laparoscopic (SIL) intraperitoneal onlay mesh (IPOM) repair for these hernias. Materials and methods: All patients referred with multiply recurrent inguinal hernias underwent SIL-IPOM from November 1 2009 to October 30 2013. A 2.5-cm infraumbilical incision was made and a SIL surgical port was placed intraperitoneally. Modified dissection techniques, namely, “chopsticks” and “inline” dissection, 5.5 mm/52 cm/30° angled laparoscope and conventional straight dissecting instruments were used. The peritoneum was incised above the symphysis pubis and dissection continued laterally and proximally raising an inferior flap, below a previous extraperitoneal mesh, while reducing any direct/indirect/femoral/cord lipoma before placement of antiadhesive mesh that was fixed into the pubic ramus as well as superiorly with nonabsorbable tacks before fixing its inferior border with fibrin sealant. The inferior peritoneal flap was then tacked back onto the mesh. Results: There were 9 male patients who underwent SIL-IPOM. Mean age was 55 years old and mean body mass index was 26.8 kg/m2. Mean mesh size was 275 cm2. Mean operation time was 125 minutes with hospital stay of 1 day and umbilical scar length of 21 mm at 4 weeks' follow-up. There were no intraoperative/postoperative complications, port-site hernias, chronic groin pain, or recurrence with mean follow-up of 20 months. Conclusions: Multiply recurrent inguinal hernias after failed conventional anterior and laparoscopic repairs can be treated safely and efficiently with SIL-IPOM. PMID:25392643
Does expanded polytetrafluoroethylene mesh really shrink after laparoscopic ventral hernia repair?
Carter, P R; LeBlanc, K A; Hausmann, M G; Whitaker, J M; Rhynes, V K; Kleinpeter, K P; Allain, B W
2012-06-01
The shrinkage of mesh has been cited as a possible explanation for hernia recurrence. Expanded polytetrafluoroethylene (ePTFE) is unique in that it can be visualized on computed tomography (CT). Some animal studies have shown a greater than 40% rate of contraction of ePTFE; however, very few human studies have been performed. A total of 815 laparoscopic incisional/ventral hernia (LIVH) repairs were performed by a single surgical group. DualMesh Plus (ePTFE) (WL Gore & Associates, Newark, DE) was placed in the majority of these patients using both transfascial sutures and tack fixation. Fifty-eight patients had postoperative CTs of the abdomen and pelvis with ePTFE and known transverse diameter of the implanted mesh. The prosthesis was measured on the CT using the AquariusNet software program (TeraRecon, San Mateo, CA), which outlines the mesh and calculates the total length. Data were collected regarding the original mesh size, known linear dimension of mesh, seroma formation, and time interval since mesh implantation in months. The mean shrinkage rate was 6.7%. The duration of implantation ranged from 6 weeks to 78 months, with a median of 15 months. Seroma was seen in 8.6% (5) of patients. No relationship was identified between the percentage of shrinkage and the original mesh size (P = 0.78), duration of time implanted (P = 0.57), or seroma formation (P = 0.074). In 27.5% (16) of patients, no shrinkage of mesh was identified. Of the patients who did experience mesh shrinkage, the range of shrinkage was 2.6-25%. Our results are markedly different from animal studies and show that ePTFE has minimal shrinkage after LIVH repair. The use of transfascial sutures in addition to tack fixation may have an implication on the mesh contraction rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo Zehua; Tang Xianzhu
Parallel transport of long mean-free-path plasma along an open magnetic field line is characterized by strong temperature anisotropy, which is driven by two effects. The first is magnetic moment conservation in a non-uniform magnetic field, which can transfer energy between parallel and perpendicular degrees of freedom. The second is decompressional cooling of the parallel temperature due to parallel flow acceleration by conventional presheath electric field which is associated with the sheath condition near the wall surface where the open magnetic field line intercepts the discharge chamber. To the leading order in gyroradius to system gradient length scale expansion, the parallelmore » transport can be understood via the Chew-Goldbeger-Low (CGL) model which retains two components of the parallel heat flux, i.e., q{sub n} associated with the parallel thermal energy and q{sub s} related to perpendicular thermal energy. It is shown that in addition to the effect of magnetic field strength (B) modulation, the two components (q{sub n} and q{sub s}) of the parallel heat flux play decisive roles in the parallel variation of the plasma profile, which includes the plasma density (n), parallel flow (u), parallel and perpendicular temperatures (T{sub Parallel-To} and T{sub Up-Tack }), and the ambipolar potential ({phi}). Both their profile (q{sub n}/B and q{sub s}/B{sup 2}) and the upstream values of the ratio of the conductive and convective thermal flux (q{sub n}/nuT{sub Parallel-To} and q{sub s}/nuT{sub Up-Tack }) provide the controlling physics, in addition to B modulation. The physics described by the CGL model are contrasted with those of the double-adiabatic laws and further elucidated by comparison with the first-principles kinetic simulation for a specific but representative flux expander case.« less
Lunar and terrestrial planet formation in the Grand Tack scenario
Jacobson, S. A.; Morbidelli, A.
2014-01-01
We present conclusions from a large number of N-body simulations of the giant impact phase of terrestrial planet formation. We focus on new results obtained from the recently proposed Grand Tack model, which couples the gas-driven migration of giant planets to the accretion of the terrestrial planets. The giant impact phase follows the oligarchic growth phase, which builds a bi-modal mass distribution within the disc of embryos and planetesimals. By varying the ratio of the total mass in the embryo population to the total mass in the planetesimal population and the mass of the individual embryos, we explore how different disc conditions control the final planets. The total mass ratio of embryos to planetesimals controls the timing of the last giant (Moon-forming) impact and its violence. The initial embryo mass sets the size of the lunar impactor and the growth rate of Mars. After comparing our simulated outcomes with the actual orbits of the terrestrial planets (angular momentum deficit, mass concentration) and taking into account independent geochemical constraints on the mass accreted by the Earth after the Moon-forming event and on the time scale for the growth of Mars, we conclude that the protoplanetary disc at the beginning of the giant impact phase must have had most of its mass in Mars-sized embryos and only a small fraction of the total disc mass in the planetesimal population. From this, we infer that the Moon-forming event occurred between approximately 60 and approximately 130 Myr after the formation of the first solids and was caused most likely by an object with a mass similar to that of Mars. PMID:25114304
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayari, Taha; Li, Xin; Voss, Paul L.
Recent advances in epitaxial growth have led to the growth of III-nitride devices on 2D layered h-BN. This advance has the potential for wafer-scale transfer to arbitrary substrates, which could improve the thermal management and would allow III-N devices to be used more flexibly in a broader range of applications. We report wafer scale exfoliation of a metal organic vapor phase epitaxy grown InGaN/GaN Multi Quantum Well (MQW) structure from a 5 nm thick h-BN layer that was grown on a 2-inch sapphire substrate. The weak van der Waals bonds between h-BN atomic layers break easily, allowing the MQW structure tomore » be mechanically lifted off from the sapphire substrate using a commercial adhesive tape. This results in the surface roughness of only 1.14 nm on the separated surface. Structural characterizations performed before and after the lift-off confirm the conservation of structural properties after lift-off. Cathodoluminescence at 454 nm was present before lift-off and 458 nm was present after. Electroluminescence near 450 nm from the lifted-off structure has also been observed. These results show that the high crystalline quality ultrathin h-BN serves as an effective sacrificial layer—it maintains performance, while also reducing the GaN buffer thickness and temperature ramps as compared to a conventional two-step growth method. These results support the use of h-BN as a low-tack sacrificial underlying layer for GaN-based device structures and demonstrate the feasibility of large area lift-off and transfer to any template, which is important for industrial scale production.« less
Taghizadeh, S Mojtaba; Moghimi-Ardakani, Ali; Mohamadnia, Fatemeh
2015-03-01
A series of drug-in-adhesive transdermal drug delivery systems (patch) with different chemical penetration enhancers were designed to deliver drug through the skin as a site of application. The objective of our effort was to study the influence of various chemical penetration enhancers on skin permeation rate and adhesion properties of a transdermal drug delivery system using Box-Behnken experimental design. The response surface methodology based on a three-level, three-variable Box-Behnken design was used to evaluate the interactive effects on dependent variables including, the rate of skin permeation and adhesion properties, namely peel strength and tack value. Levulinic acid, lauryl alcohol, and Tween 80 were used as penetration enhancers (patch formulations, containing 0-8% of each chemical penetration enhancer). Buprenorphine was used as a model penetrant drug. The results showed that incorporation of 20% chemical penetration enhancer into the mixture led to maximum skin permeation flux of buprenorphine from abdominal rat skin while the adhesion properties decreased. Also that skin flux in presence of levulinic acid (1.594 μg/cm(2) h) was higher than Tween 80 (1.473 μg/cm(2) h) and lauryl alcohol (0.843 μg/cm(2) h), and in mixing these enhancers together, an additional effect was observed. Moreover, it was found that each enhancer increased the tack value, while levulinic acid and lauryl alcohol improved the peel strength but Tween 80 reduced it. These findings indicated that the best chemical skin penetration enhancer for buprenorphine patch was levulinic acid. Among the designed formulations, the one which contained 12% (wt/wt) enhancers exhibited the highest efficiency.
Lunar and terrestrial planet formation in the Grand Tack scenario.
Jacobson, S A; Morbidelli, A
2014-09-13
We present conclusions from a large number of N-body simulations of the giant impact phase of terrestrial planet formation. We focus on new results obtained from the recently proposed Grand Tack model, which couples the gas-driven migration of giant planets to the accretion of the terrestrial planets. The giant impact phase follows the oligarchic growth phase, which builds a bi-modal mass distribution within the disc of embryos and planetesimals. By varying the ratio of the total mass in the embryo population to the total mass in the planetesimal population and the mass of the individual embryos, we explore how different disc conditions control the final planets. The total mass ratio of embryos to planetesimals controls the timing of the last giant (Moon-forming) impact and its violence. The initial embryo mass sets the size of the lunar impactor and the growth rate of Mars. After comparing our simulated outcomes with the actual orbits of the terrestrial planets (angular momentum deficit, mass concentration) and taking into account independent geochemical constraints on the mass accreted by the Earth after the Moon-forming event and on the time scale for the growth of Mars, we conclude that the protoplanetary disc at the beginning of the giant impact phase must have had most of its mass in Mars-sized embryos and only a small fraction of the total disc mass in the planetesimal population. From this, we infer that the Moon-forming event occurred between approximately 60 and approximately 130 Myr after the formation of the first solids and was caused most likely by an object with a mass similar to that of Mars. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2013 CFR
2013-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2014 CFR
2014-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
Code of Federal Regulations, 2012 CFR
2012-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2013 CFR
2013-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2012 CFR
2012-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
49 CFR 572.174 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... assembled dummy (drawing 420-0000) (incorporated by reference, see § 572.170) is impacted by a test probe... this specified compression corridor, the peak force, measured by the impact probe as defined in section... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.174 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... assembled dummy (drawing 420-0000) (incorporated by reference, see § 572.170) is impacted by a test probe... this specified compression corridor, the peak force, measured by the impact probe as defined in section... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.174 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... assembled dummy (drawing 420-0000) (incorporated by reference, see § 572.170) is impacted by a test probe... this specified compression corridor, the peak force, measured by the impact probe as defined in section... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Solar probe shield developmental testing
NASA Technical Reports Server (NTRS)
Miyake, Robert N.
1991-01-01
The objectives of the Solar Probe mission and the current status of the Solar Probe thermal shield subsystem development are described. In particular, the discussion includes a brief description of the mission concepts, spacecraft configuration and shield concept, material selection criteria, and the required material testing to provide a database to support the development of the shield system.
NASA Technical Reports Server (NTRS)
Bobbitt, Percy J.; Maglieri, Domenic J.; Banks, Daniel W.; Fuchs, Aaron W.
2011-01-01
Wedge and conical shaped probes for the measurement of free-stream flow quantities at supersonic speeds have been tested in both wind tunnel and flight. These probes have improved capabilities over similar ones used in the past. Through the use of miniature pressure sensors, that are located inside the probes, they are able to provide instantaneous measurements of a time-varying environment. Detailed herein are the results of the tests in NASA Langley Researcher Center s Unitary Plan Wind Tunnel (UPWT) at Mach numbers of 1.6, 1.8 and 2.0, as well as flight tests carried out at the NASA Dryden Flight Research Center (DFRC) on its F-15 aircraft up to Mach numbers of 1.9. In the flight tests the probes were attached to a fixture on the underside of the F-15 fuselage. Problems controlling the velocity of the flow through the conical probe, required for accurate temperature measurements, are noted, as well as some calibration problems of the miniature pressure sensors that impact the accuracy of the measurements.
NASA Technical Reports Server (NTRS)
Bobbitt, Percy J.; Maglieri, Domenic J.; Banks, Daniel W.; Frederick, Michael A.; Fuchs, Aaron W.
2012-01-01
The results of supersonic wind-tunnel tests on three probes at nominal Mach numbers of 1.6, 1.8 and 2.0 and flight tests on two of these probes up to a Mach number of 1.9 are described. One probe is an 8 deg. half-angle wedge with two total-pressure measurements and one static. The second, a conical probe, is a cylinder that has a 15 deg., semi-angle cone tip with one total-pressure orifice at the apex and four static-pressure orifices on the surface of the cone, 90 deg. apart, and about two-thirds of the distance from the cone apex to the base of the cone. The third is a 2 deg. semi-angle cone that has two static ports located 180 deg. apart about 1.5 inches behind the apex of the cone. The latter probe was included since it has been the "probe of choice" for wind-tunnel flow-field pressure measurements (or one similar to it) for the past half-century. The wedge and 15 deg. conical probes used in these tests were designed for flight diagnostic measurements for flight Mach numbers down to 1.35 and 1.15 respectively, and have improved capabilities over earlier probes of similar shape. The 15. conical probe also has a temperature sensor that is located inside the cylindrical part of the probe that is exposed to free-stream flow through an annulus at the apex of the cone. It enables the determination of free-stream temperature, density, speed of sound, and velocity, in addition to free-stream pressure, Mach number, angle of attack and angle of sideslip. With the time-varying velocity, acceleration can be calculated. Wind-tunnel tests of the two probes were made in NASA Langley Research Center fs Unitary Plan Wind Tunnel (UPWT) at Mach numbers of 1.6, 1.8, and 2.0. Flight tests were carried out at the NASA Dryden Flight Research Center (DFRC) on its F-15B aircraft up to Mach numbers of 1.9. The probes were attached to a fixture, referred to as the Centerline Instrumented Pylon (CLIP), under the fuselage of the aircraft. Problems controlling the velocity of the flow through the conical probe required for accurate temperature measurements are noted, as well as some calibration problems of the miniature pressure sensors that required a re-calculation of the flow variables. Data are presented for angle of attack, pressure and Mach number obtained in the wind tunnel and in flight. In the wind tunnel some transient data were obtained by translating the probes through the shock flow field created by a bump on the wind-tunnel wall.
Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter
2016-06-01
To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three were deceased, two were in nursing homes, and three could not be located. Aged patients receiving dental implants had excellent implant survival rates, low periodontal disease index scores with minimal changes in interproximal bone levels. Results from this study indicate that patients with advanced age, in reasonably good health, have excellent implant survival rates, excellent quality of life scores, and can be maintained in good oral health. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Danforth, Richard A.
1991-01-01
Qualification of the full-scale process and design changes for elimination of redesigned solid rocket motor tang nitrile butadiene rubber insulation edge separations and voids was performed from 24 March to 3 December 1990. The objectives of this test were: to qualify design and process changes on flight hardware using a tie ply between the redesigned solid rocket motor steel case and the nitrile butadiene rubber insulation over the tang capture features; to qualify the use of methyl ethyl ketone in the tang flap region to reduce voids; and to determine if holes in the separator film reduce voids in the tang flap region. The tie ply is intended to aid insulation flow during the insulation cure process, and thus reduce or eliminate edge unbonds. Methyl ethyl ketone is intended to reduce voids in the tang flap area by providing better tacking characteristics. The perforated film was intended to provide possible vertical breathe paths to reduce voids in the tang area. Tang tie ply testing consisted of 270 deg of the tang circumference using a new layup method and 90 deg of the tang circumference using the current layup methods. Tie ply process success was defined as a reduction of insulation unbonds. Lack of any insulation edge unbonds on the tang area where the new process was used, and the presence of 17 unbonds with the current process, proves the test to be a success. Successful completion of this test has qualified the new processes.
Wimpee, C F; Nadeau, T L; Nealson, K H
1991-01-01
By using two highly conserved region of the luxA gene as primers, polymerase chain reaction amplification methods were used to prepare species-specific probes against the luciferase gene from four major groups of marine luminous bacteria. Laboratory studies with test strains indicated that three of the four probes cross-reacted with themselves and with one or more of the other species at low stringencies but were specific for members of their own species at high stringencies. The fourth probe, generated from Vibrio harveyi DNA, cross-reacted with DNAs from two closely related species, V. orientalis and V. vulnificus. When nonluminous cultures were tested with the species-specific probes, no false-positive results were observed, even at low stringencies. Two field isolates were correctly identified as Photobacterium phosphoreum by using the species-specific hybridization probes at high stringency. A mixed probe (four different hybridization probes) used at low stringency gave positive results with all of the luminous bacteria tested, including the terrestrial species, Xenorhabdus luminescens, and the taxonomically distinct marine bacterial species Shewanella hanedai; minimal cross-hybridization with these species was seen at higher stringencies. Images PMID:1854194
Hui, Ling; Geiersbach, Katherine B; Downs-Kelly, Erinn; Gulbahce, H Evin
2017-02-01
-In 2013 the American Society of Clinical Oncology and College of American Pathologists updated the HER2 guidelines and changed the equivocal category for HER2 in situ hybridization testing to an average HER2 copy number of 4.0 to 5.9 with a HER2:CEP17 ratio of less than 2.0 and proposed retesting, with an option of using another control probe to avoid false-negative results. RAI1, located at band position 17p11.2, is a popular alternate probe locus for retesting equivocal changes. -To review experience with the RAI1 alternate probe in HER2 fluorescence in situ hybridization equivocal breast cancers. -Primary and metastatic breast cancers with equivocal HER2 fluorescence in situ hybridization, retested with an alternate (RAI1) probe, were identified. HER2, RAI1, and CEP17 copy numbers, HER2 to control probe ratios, and genetic heterogeneity were recorded. Hematoxylin-eosin-stained slides were reviewed for type and grade of cancer. -Of 876 cases tested with CEP17 as the reference probe, 97 (11.1%) had equivocal HER2 fluorescence in situ hybridization results. Additional testing with the RAI1 probe classified 39.2% cases (38 of 97) as amplified with a HER2:RAI1 ratio ranging from 2.0 to 3.2 (mean, 2.37); 3.1% (3 of 97) were still unclassifiable because of a deletion of RAI1. -RAI1 identified close to 40% of original HER2 fluorescence in situ hybridization equivocal cases as amplified, making these patients eligible for targeted therapies. It is not known whether guidelines for US Food and Drug Administration-approved probes can be extrapolated to alternate probes when an alternate control probe shows losses or gains. Because of the lack of guidelines for reporting HER2 status with alternate probes, laboratories face challenges in interpreting results.
Eye Movements in Implicit Artificial Grammar Learning
ERIC Educational Resources Information Center
Silva, Susana; Inácio, Filomena; Folia, Vasiliki; Petersson, Karl Magnus
2017-01-01
Artificial grammar learning (AGL) has been probed with forced-choice behavioral tests (active tests). Recent attempts to probe the outcomes of learning (implicitly acquired knowledge) with eye-movement responses (passive tests) have shown null results. However, these latter studies have not tested for sensitivity effects, for example, increased…
Application of a Split-Fiber Probe to Velocity Measurement in the NASA Research Compressor
NASA Technical Reports Server (NTRS)
Lepicovsky, Jan
2003-01-01
A split-fiber probe was used to acquire unsteady data in a research compressor. The probe has two thin films deposited on a quartz cylinder 200 microns in diameter. A split-fiber probe allows simultaneous measurement of velocity magnitude and direction in a plane that is perpendicular to the sensing cylinder, because it has its circumference divided into two independent parts. Local heat transfer considerations indicated that the probe direction characteristic is linear in the range of flow incidence angles of +/- 35. Calibration tests confirmed this assumption. Of course, the velocity characteristic is nonlinear as is typical in thermal anemometry. The probe was used extensively in the NASA Glenn Research Center (GRC) low-speed, multistage axial compressor, and worked reliably during a test program of several months duration. The velocity and direction characteristics of the probe showed only minute changes during the entire test program. An algorithm was developed to decompose the probe signals into velocity magnitude and velocity direction. The averaged unsteady data were compared with data acquired by pneumatic probes. An overall excellent agreement between the averaged data acquired by a split-fiber probe and a pneumatic probe boosts confidence in the reliability of the unsteady content of the split-fiber probe data. To investigate the features of unsteady data, two methods were used: ensemble averaging and frequency analysis. The velocity distribution in a rotor blade passage was retrieved using the ensemble averaging method. Frequencies of excitation forces that may contribute to high cycle fatigue problems were identified by applying a fast Fourier transform to the absolute velocity data.
NASA Technical Reports Server (NTRS)
Foote, C. H.
1980-01-01
Results from the altitude testing of a P sub T/P sub S noseboom probe on the F100 engine are discused. The results are consistent with sea level test results. The F100 engine altitude test verified automatic downmatch with the engine pressure ratio control, and backup control inlet case static pressure demonstrated sufficient accuracy for backup control fuel flow scheduling. The production P6 probe measured Station 6 pressures accurately for both undistorted and distorted inlet airflows.
Flight evaluation of an engine static pressure noseprobe in an F-15 airplane
NASA Technical Reports Server (NTRS)
Foote, C. H.; Jaekel, R. F.
1981-01-01
The flight testing of an inlet static pressure probe and instrumented inlet case produced results consistent with sea-level and altitude stand testing. The F-15 flight test verified the basic relationship of total to static pressure ratio versus corrected airflow and automatic distortion downmatch with the engine pressure ratio control mode. Additionally, the backup control inlet case statics demonstrated sufficient accuracy for backup control fuel flow scheduling, and the station 6 manifolded production probe was in agreement with the flight test station 6 tota pressure probes.
Development of subminiature multi-sensor hot-wire probes
NASA Technical Reports Server (NTRS)
Westphal, Russell V.; Ligrani, Phillip M.; Lemos, Fred R.
1988-01-01
Limitations on the spatial resolution of multisensor hot wire probes have precluded accurate measurements of Reynolds stresses very near solid surfaces in wind tunnels and in many practical aerodynamic flows. The fabrication, calibration and qualification testing of very small single horizontal and X-array hot-wire probes which are intended to be used near solid boundaries in turbulent flows where length scales are particularly small, is described. Details of the sensor fabrication procedure are reported, along with information needed to successfully operate the probes. As compared with conventional probes, manufacture of the subminiature probes is more complex, requiring special equipment and careful handling. The subminiature probes tested were more fragile and shorter lived than conventional probes; they obeyed the same calibration laws but with slightly larger experimental uncertainty. In spite of these disadvantages, measurements of mean statistical quantities and spectra demonstrate the ability of the subminiature sensors to provide the measurements in the near wall region of turbulent boundary layers that are more accurate than conventional sized probes.
NASA Technical Reports Server (NTRS)
Hale, L. C.
1977-01-01
A low cost conductivity probe system for use with the Super Loki Dart meteorological sounding rocket is described. Miniaturization of the Super Arcas blunt probe, operation of the blunt probe experiment, flight tests, and development of a Lyman-alpha probe are among the topics discussed.
NASA Technical Reports Server (NTRS)
Baskaran, Subbiah; Ramachandran, Narayanan; Noever, David
1998-01-01
The use of probabilistic (PNN) and multilayer feed forward (MLFNN) neural networks are investigated for calibration of multi-hole pressure probes and the prediction of associated flow angularity patterns in test flow fields. Both types of networks are studied in detail for their calibration and prediction characteristics. The current formalism can be applied to any multi-hole probe, however the test results for the most commonly used five-hole Cone and Prism probe types alone are reported in this article.
16 CFR 1509.13 - Requirements for cutouts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... cribs shall comply with the following test requirements: (a) Place the neck of the headform probe shown... the point of contact. The head portion of the probe shall be on the outer side of the panel. With the... may test at all points that could result in a failure), and the front of the probe pointing downwards...
A Probe for Measuring Moisture Content in Dead Roundwood
Richard W. Blank; John S. Frost; James E. Eenigenburg
1983-01-01
This paper reports field test results of a wood moisture probe''s accuracy in measuring fuel moisture content of dead roundwood. Probe measurements, corrected for temperature, correlated well with observed fuel moistures of 1-inch dead jack pine branchwood.
Curious eyes: individual differences in personality predict eye movement behavior in scene-viewing.
Risko, Evan F; Anderson, Nicola C; Lanthier, Sophie; Kingstone, Alan
2012-01-01
Visual exploration is driven by two main factors - the stimuli in our environment, and our own individual interests and intentions. Research investigating these two aspects of attentional guidance has focused almost exclusively on factors common across individuals. The present study took a different tack, and examined the role played by individual differences in personality. Our findings reveal that trait curiosity is a robust and reliable predictor of an individual's eye movement behavior in scene-viewing. These findings demonstrate that who a person is relates to how they move their eyes. Copyright © 2011 Elsevier B.V. All rights reserved.
1983-12-01
100 - - 75 IP - - - Ti TFB 64 - - 92 100 100 - - - Ti TF(A+B) 82 - - 84 50 100 - - - C(2x2) Ti ATOP - - - 98 50 - - - V ATOP 56 - - 81 67 iP - 100 100...Nb ATOP 100 100 - 74 40 - X X - Ti BR 40 - - 92 100 100 IP IP - Ti TRA 33 - - 80 50 - - - Ti TFB 86 X - 73 100 - 50 - - Ti TR(A+B) 60 x - 77 75 - 50...NOTE: A tack (-) indicates that the species was not formed, while "X" indicates that none were formed by frag- mentation. IP indicates that only
Leaf seal for gas turbine stator shrouds and a nozzle band
Burdgick, Steven Sebastian; Sexton, Brendan Francis
2002-01-01
A leaf seal assembly is secured to the trailing edge of a shroud segment for sealing between the shroud segment and the leading edge side wall of a nozzle outer band. The leaf seal includes a circumferentially elongated seal plate biased by a pair of spring clips disposed in a groove along the trailing edge of the shroud segment to maintain the seal plate in engagement with the flange on the leading edge side wall of the nozzle outer band. The leaf seal plate and spring clips receive pins tack-welded to the shroud segment to secure the leaf seal assembly in place.
Tackifier for addition polyimides containing monoethylphthalate
NASA Technical Reports Server (NTRS)
St.clair, T. L.; Butler, J. M. (Inventor)
1981-01-01
An improvement of addition polyimides wherein an essentially solventless, high viscosity laminating resin is synthesized from low cost liquid monomers is disclosed. The improved process takes advantage of a reactive, liquid plasticizer such as monoethylphthalate (MEP) which is used in lieu of an alcohol solvent, and helps solve a major problem of maintaining good prepreg tack and drape, or the ability of the prepreg to adhere to adjacent plies and conform to a desired shape during the layup process. This improvement results in both longer life of the polymer prepreg and the processing of low void laminate and appears to be applicable to all addition polyimide systems.
Intraoperative probe detecting β- decays in brain tumour radio-guided surgery
NASA Astrophysics Data System (ADS)
Solfaroli Camillocci, E.; Bocci, V.; Chiodi, G.; Collamati, F.; Donnarumma, R.; Faccini, R.; Mancini Terracciano, C.; Marafini, M.; Mattei, I.; Muraro, S.; Recchia, L.; Rucinski, A.; Russomando, A.; Toppi, M.; Traini, G.; Morganti, S.
2017-02-01
Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β- emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β- emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on "ex vivo" specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.
A beam current density monitor for intense electron beams
NASA Astrophysics Data System (ADS)
Fiorito, R. B.; Raleigh, M.; Seltzer, S. M.
1983-12-01
The authors describe a new type of electric probe for mapping the radial current density profile of high-energy, high current electron beams. The idea of developing an electrically sensitive probe for these conditions was originally suggested to one of the authors during a year's visit to the Lawrence Livermore National Laboratory. The resulting probe is intended for use on the Experimental Test Accelerator (ETA) and the Advanced Test Accelerator at that laboratory. This report discusses in detail: the mechanical design, the electrical response, and temperature effects, as they pertain to the electric probe, and describe the first experimental results obtained using this probe on ETA.
NASA Technical Reports Server (NTRS)
Wilder, M. C.; Reda, D. C.; Bogdanoff, D. W.; Olejniczak, J.
2005-01-01
A viewgraph presentation on aerothermodynamic testing of aerocapture and planetary probe design methods in hypersonic ballistic range environments is shown. The topics include: 1) Ballistic Range Testing; 2) NASA-Ames Hypervelocity Free Flight Facility; and 3) Representative Results.
NON-DESTRUCTIVE METHOD AND MEANS FOR FLAW DETECTION
Hochschild, R.
1959-03-10
BS>An improved method is presented for the nondestructive detection of flaws in olectrictilly conductivc articles using magnetic field. According to thc method a homogoneous mignetic field is established in the test article;it right angle" to the artyicle. A probe is aligned with its axis transverse to the translates so hat th4 probe scans the surface of the test article while the axis of the robe is transverse to the direction of translation of the article. In this manner any output current obtained in thc probe is an indication of the size and location of a flaw in the article under test, with a miiiimum of signal pick- up in the probe from the established magnetic field.
Measurement of Turbulent Pressure and Temperature Fluctuations in a Gas Turbine Combustor
NASA Technical Reports Server (NTRS)
Povinelli, Louis (Technical Monitor); LaGraff, John E.; Bramanti, Cristina; Pldfield, Martin; Passaro, Andrea; Biagioni, Leonardo
2004-01-01
The report summarizes the results of the redesign efforts directed towards the gas-turbine combustor rapid-injector flow diagnostic probe developed under sponsorship of NASA-GRC and earlier reported in NASA-CR-2003-212540. Lessons learned during the theoretical development, developmental testing and field-testing in the previous phase of this research were applied to redesign of both the probe sensing elements and of the rapid injection device. This redesigned probe (referred to herein as Turboprobe) has been fabricated and is ready, along with the new rapid injector, for field-testing. The probe is now designed to capture both time-resolved and mean total temperatures, total pressures and, indirectly, one component of turbulent fluctuations.
Spatial-scanning hyperspectral imaging probe for bio-imaging applications
NASA Astrophysics Data System (ADS)
Lim, Hoong-Ta; Murukeshan, Vadakke Matham
2016-03-01
The three common methods to perform hyperspectral imaging are the spatial-scanning, spectral-scanning, and snapshot methods. However, only the spectral-scanning and snapshot methods have been configured to a hyperspectral imaging probe as of today. This paper presents a spatial-scanning (pushbroom) hyperspectral imaging probe, which is realized by integrating a pushbroom hyperspectral imager with an imaging probe. The proposed hyperspectral imaging probe can also function as an endoscopic probe by integrating a custom fabricated image fiber bundle unit. The imaging probe is configured by incorporating a gradient-index lens at the end face of an image fiber bundle that consists of about 50 000 individual fiberlets. The necessary simulations, methodology, and detailed instrumentation aspects that are carried out are explained followed by assessing the developed probe's performance. Resolution test targets such as United States Air Force chart as well as bio-samples such as chicken breast tissue with blood clot are used as test samples for resolution analysis and for performance validation. This system is built on a pushbroom hyperspectral imaging system with a video camera and has the advantage of acquiring information from a large number of spectral bands with selectable region of interest. The advantages of this spatial-scanning hyperspectral imaging probe can be extended to test samples or tissues residing in regions that are difficult to access with potential diagnostic bio-imaging applications.
NASA Technical Reports Server (NTRS)
Rediniotis, Othon K.
1999-01-01
Two new calibration algorithms were developed for the calibration of non-nulling multi-hole probes in compressible, subsonic flowfields. The reduction algorithms are robust and able to reduce data from any multi-hole probe inserted into any subsonic flowfield to generate very accurate predictions of the velocity vector, flow direction, total pressure and static pressure. One of the algorithms PROBENET is based on the theory of neural networks, while the other is of a more conventional nature (polynomial approximation technique) and introduces a novel idea of local least-squares fits. Both algorithms have been developed to complete, user-friendly software packages. New technology was developed for the fabrication of miniature multi-hole probes, with probe tip diameters all the way down to 0.035". Several miniature 5- and 7-hole probes, with different probe tip geometries (hemispherical, conical, faceted) and different overall shapes (straight, cobra, elbow probes) were fabricated, calibrated and tested. Emphasis was placed on the development of four stainless-steel conical 7-hole probes, 1/16" in diameter calibrated at NASA Langley for the entire subsonic regime. The developed calibration algorithms were extensively tested with these probes demonstrating excellent prediction capabilities. The probes were used in the "trap wing" wind tunnel tests in the 14'x22' wind tunnel at NASA Langley, providing valuable information on the flowfield over the wing. This report is organized in the following fashion. It consists of a "Technical Achievements" section that summarizes the major achievements, followed by an assembly of journal articles that were produced from this project and ends with two manuals for the two probe calibration algorithms developed.
Im, Jooeun; Kim, Mihyun; Choi, Ki-Sun; Hwang, Tae-Kyung; Kwon, Il-Bum
2014-06-10
In this paper, new fiber Bragg grating (FBG) sensor probes are designed to intermittently detect the maximum tensile strain of composite materials, so as to evaluate the structural health status. This probe is fabricated by two thin Al films bonded to an FBG optical fiber and two supporting brackets, which are fixed on the surface of composite materials. The residual strain of the Al packaged FBG sensor probe is induced by the strain of composite materials. This residual strain can indicate the maximum strain of composite materials. Two types of sensor probes are prepared-one is an FBG with 18 μm thick Al films, and the other is an FBG with 36 μm thick Al films-to compare the thickness effect on the detection sensitivity. These sensor probes are bonded on the surfaces of carbon fiber reinforced plastics composite specimens. In order to determine the strain sensitivity between the residual strain of the FBG sensor probe and the maximum strain of the composite specimen, tensile tests are performed by universal testing machine, under the loading-unloading test condition. The strain sensitivities of the probes, which have the Al thicknesses of 18 and 36 μm, are determined as 0.13 and 0.23, respectively.
In-flight comparisons of boundary-layer and wake measurement probes for incompressible flow
NASA Technical Reports Server (NTRS)
Mertaugh, L. J., Jr.
1972-01-01
The results are presented of in-flight comparisons of a number of boundary-layer and wake measurement probes suitable for low-speed flight-test investigations. The tested boundary-layer probes included a traversing total-pressure probe and a hot-film probe mounted on an internally-mounted drive mechanism, a curved and a straight boundary-layer rake, and a traversing hot-film probe with an externally-mounted drive mechanism. The wake measuring devices included a traversing, self-aligning probe, a wake rake, and an integrating wake rate. The boundary-layer data are compared with a common reference velocity profile and comments given regarding the accuracy of the static-pressure and total-pressure measurements. Discussions on the various calibration presentations used with hot-wire and hot-film sensors and various aspects of improving the accuracy of hot-film sensor results are given in the appendix of this report.
Zhang, M Z; Zhang, X F; Chen, X M; Chen, X; Wu, S; Xu, L L
2015-08-10
The enzyme-linked probe hybridization chip utilizes a method based on ligase-hybridizing probe chip technology, with the principle of using thio-primers for protection against enzyme digestion, and using lambda DNA exonuclease to cut multiple PCR products obtained from the sample being tested into single-strand chains for hybridization. The 5'-end amino-labeled probe was fixed onto the aldehyde chip, and hybridized with the single-stranded PCR product, followed by addition of a fluorescent-modified probe that was then enzymatically linked with the adjacent, substrate-bound probe in order to achieve highly specific, parallel, and high-throughput detection. Specificity and sensitivity testing demonstrated that enzyme-linked probe hybridization technology could be applied to the specific detection of eight genetic modification events at the same time, with a sensitivity reaching 0.1% and the achievement of accurate, efficient, and stable results.
Versatile robotic probe calibration for position tracking in ultrasound imaging.
Bø, Lars Eirik; Hofstad, Erlend Fagertun; Lindseth, Frank; Hernes, Toril A N
2015-05-07
Within the field of ultrasound-guided procedures, there are a number of methods for ultrasound probe calibration. While these methods are usually developed for a specific probe, they are in principle easily adapted to other probes. In practice, however, the adaptation often proves tedious and this is impractical in a research setting, where new probes are tested regularly. Therefore, we developed a method which can be applied to a large variety of probes without adaptation. The method used a robot arm to move a plastic sphere submerged in water through the ultrasound image plane, providing a slow and precise movement. The sphere was then segmented from the recorded ultrasound images using a MATLAB programme and the calibration matrix was computed based on this segmentation in combination with tracking information. The method was tested on three very different probes demonstrating both great versatility and high accuracy.
Versatile robotic probe calibration for position tracking in ultrasound imaging
NASA Astrophysics Data System (ADS)
Eirik Bø, Lars; Fagertun Hofstad, Erlend; Lindseth, Frank; Hernes, Toril A. N.
2015-05-01
Within the field of ultrasound-guided procedures, there are a number of methods for ultrasound probe calibration. While these methods are usually developed for a specific probe, they are in principle easily adapted to other probes. In practice, however, the adaptation often proves tedious and this is impractical in a research setting, where new probes are tested regularly. Therefore, we developed a method which can be applied to a large variety of probes without adaptation. The method used a robot arm to move a plastic sphere submerged in water through the ultrasound image plane, providing a slow and precise movement. The sphere was then segmented from the recorded ultrasound images using a MATLAB programme and the calibration matrix was computed based on this segmentation in combination with tracking information. The method was tested on three very different probes demonstrating both great versatility and high accuracy.
Can quantum probes satisfy the weak equivalence principle?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seveso, Luigi, E-mail: luigi.seveso@unimi.it; Paris, Matteo G.A.; INFN, Sezione di Milano, I-20133 Milano
We address the question whether quantum probes in a gravitational field can be considered as test particles obeying the weak equivalence principle (WEP). A formulation of the WEP is proposed which applies also in the quantum regime, while maintaining the physical content of its classical counterpart. Such formulation requires the introduction of a gravitational field not to modify the Fisher information about the mass of a freely-falling probe, extractable through measurements of its position. We discover that, while in a uniform field quantum probes satisfy our formulation of the WEP exactly, gravity gradients can encode nontrivial information about the particle’smore » mass in its wavefunction, leading to violations of the WEP. - Highlights: • Can quantum probes under gravity be approximated as test-bodies? • A formulation of the weak equivalence principle for quantum probes is proposed. • Quantum probes are found to violate it as a matter of principle.« less
49 CFR 572.77 - Instrumentation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 7 2011-10-01 2011-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...
49 CFR 572.77 - Instrumentation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 7 2013-10-01 2013-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...
49 CFR 572.77 - Instrumentation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 7 2012-10-01 2012-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...
49 CFR 572.77 - Instrumentation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 7 2014-10-01 2014-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...
Development of Mackintosh Probe Extractor
NASA Astrophysics Data System (ADS)
Rahman, Noor Khazanah A.; Kaamin, Masiri; Suwandi, Amir Khan; Sahat, Suhaila; Jahaya Kesot, Mohd
2016-11-01
Dynamic probing is a continuous soil investigation technique, which is one of the simplest soil penetration test. It basically consist of repeatedly driving a metal tipped probe into the ground using a drop weight of fixed mass and travel. Testing was carried out continuously from ground level to the final penetration depth. Once the soil investigation work done, it is difficult to pull out the probe rod from the ground, due to strong soil structure grip against probe cone and prevent the probe rod out from the ground. Thus, in this case, a tool named Extracting Probe was created to assist in the process of retracting the probe rod from the ground. In addition, Extracting Probe also can reduce the time to extract the probe rod from the ground compare with the conventional method. At the same time, it also can reduce manpower cost because only one worker involve to handle this tool compare with conventional method used two or more workers. From experiment that have been done we found that the time difference between conventional tools and extracting probe is significant, average time difference is 155 minutes. In addition the extracting probe can reduce manpower usage, and also labour cost for operating the tool. With all these advantages makes this tool has the potential to be marketed.
NASA Technical Reports Server (NTRS)
Porro, A. Robert
2000-01-01
A series of dynamic flow field pressure probes were developed for use in large-scale supersonic wind tunnels at NASA Glenn Research Center. These flow field probes include pitot, static, and five-hole conical pressure probes that are capable of capturing fast acting flow field pressure transients that occur on a millisecond time scale. The pitot and static probes can be used to determine local Mach number time histories during a transient event. The five-hole conical pressure probes are used primarily to determine local flow angularity, but can also determine local Mach number. These probes were designed, developed, and tested at the NASA Glenn Research Center. They were also used in a NASA Glenn 10-by 10-Foot Supersonic Wind Tunnel (SWT) test program where they successfully acquired flow field pressure data in the vicinity of a propulsion system during an engine compressor staff and inlet unstart transient event. Details of the design, development, and subsequent use of these probes are discussed in this report.
A congruent phylogenomic signal places eukaryotes within the Archaea.
Williams, Tom A; Foster, Peter G; Nye, Tom M W; Cox, Cymon J; Embley, T Martin
2012-12-22
Determining the relationships among the major groups of cellular life is important for understanding the evolution of biological diversity, but is difficult given the enormous time spans involved. In the textbook 'three domains' tree based on informational genes, eukaryotes and Archaea share a common ancestor to the exclusion of Bacteria. However, some phylogenetic analyses of the same data have placed eukaryotes within the Archaea, as the nearest relatives of different archaeal lineages. We compared the support for these competing hypotheses using sophisticated phylogenetic methods and an improved sampling of archaeal biodiversity. We also employed both new and existing tests of phylogenetic congruence to explore the level of uncertainty and conflict in the data. Our analyses suggested that much of the observed incongruence is weakly supported or associated with poorly fitting evolutionary models. All of our phylogenetic analyses, whether on small subunit and large subunit ribosomal RNA or concatenated protein-coding genes, recovered a monophyletic group containing eukaryotes and the TACK archaeal superphylum comprising the Thaumarchaeota, Aigarchaeota, Crenarchaeota and Korarchaeota. Hence, while our results provide no support for the iconic three-domain tree of life, they are consistent with an extended eocyte hypothesis whereby vital components of the eukaryotic nuclear lineage originated from within the archaeal radiation.
Out-Life Characteristics of IM7/977-3 Composites
NASA Technical Reports Server (NTRS)
Miller, Sandi G.; Sutter, James K.; Hou, Tan-Hung; Scheiman, Daniel A.; Martin, Richard E.; Maryanski, Michael; Schlea, Michelle; Gardner, John M.; Schiferl, Zack R.
2010-01-01
The capability to manufacture large structures leads to weight savings and reduced risk relative to joining smaller components. However, manufacture of increasingly large composite components is pushing the out-time limits of epoxy/ carbon fiber prepreg. IM7/977-3 is an autoclave processable prepreg material, commonly used in aerospace structures. The out-time limit is reported as 30 days by the manufacturer. The purpose of this work was to evaluate the material processability and composite properties of 977-3 resin and IM7/977-3 prepreg that had been aged at room temperature for up to 60 days. The effects of room temperature aging on the thermal and visco-elastic properties of the materials were investigated. Neat resin was evaluated by differential scanning calorimetry to characterize thermal properties and change in activation energy of cure. Neat resin was also evaluated by rheometry to characterize its processability in composite fabrication. IM7/977-3 prepreg was evaluated by dynamic mechanical analysis to characterize the curing behavior. Prepreg tack was also evaluated over 60 days. The overall test results suggested that IM7/977-3 was a robust material that offered quality laminates throughout this aging process when processed by autoclave.
Design and Operation of a Fast, Thin-Film Thermocouple Probe on a Turbine Engine
NASA Technical Reports Server (NTRS)
Meredith, Roger D.; Wrbanek, John D.; Fralick, Gustave C.; Greer, Lawrence C., III; Hunter, Gary W.; Chen, Liang-Yu
2014-01-01
As a demonstration of technology maturation, a thin-film temperature sensor probe was fabricated and installed on a F117 turbofan engine via a borescope access port to monitor the temperature experienced in the bleed air passage of the compressor area during an engine checkout test run. To withstand the harsh conditions experienced in this environment, the sensor probe was built from high temperature materials. The thin-film thermocouple sensing elements were deposited by physical vapor deposition using pure metal elements, thus avoiding the inconsistencies of sputter-depositing particular percentages of materials to form standardized alloys commonly found in thermocouples. The sensor probe and assembly were subjected to a strict protocol of multi-axis vibrational testing as well as elevated temperature pressure testing to be qualified for this application. The thin-film thermocouple probe demonstrated a faster response than a traditional embedded thermocouple during the engine checkout run.
NASA Astrophysics Data System (ADS)
Viator, John A.; Paltauf, Guenther; Jacques, Steven L.; Prahl, Scott A.
2001-06-01
An endoscopic photoacoustic probe is designed and tested for use in PDT treatment of esophageal cancer. The probe, measuring less than 2.5 mm in diameter, was designed to fit within the lumen of an endoscope that will be inserted into an esophagus after PDT. PDT treatment results in a blanched, necrotic layer of cancerous tissue over a healthy, deeper layer of perfused tissue. The photoacoustic probe was designed to use acoustic propagation time to determine the thickness of the blanched surface of the esophagus, which corresponds to treatment depth. A side-firing 600 micrometers fiber delivered 532 nm laser light to induce acoustic waves in the perfused layer of the esophagus beneath the blanched (treated) layer. A PVDF transducer detected the induced acoustic waves and transmitted the signal to an oscilloscope. The probe was tested on clear and turbid tissue phantom layers over an optically absorbing dye solution.
Becságh, Péter; Szakács, Orsolya
2014-10-01
During diagnostic workflow when detecting sequence alterations, sometimes it is important to design an algorithm that includes screening and direct tests in combination. Normally the use of direct test, which is mainly sequencing, is limited. There is an increased need for effective screening tests, with "closed tube" during the whole process and therefore decreasing the risk of PCR product contamination. The aim of this study was to design such a closed tube, detection probe based screening assay to detect different kind of sequence alterations in the exon 11 of the human c-kit gene region. Inside this region there are variable possible deletions and single nucleotide changes. During assay setup, more probe chemistry formats were screened and tested. After some optimization steps the taqman probe format was selected.
49 CFR 572.144 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.144 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.144 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.144 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Design of 240,000 orthogonal 25mer DNA barcode probes.
Xu, Qikai; Schlabach, Michael R; Hannon, Gregory J; Elledge, Stephen J
2009-02-17
DNA barcodes linked to genetic features greatly facilitate screening these features in pooled formats using microarray hybridization, and new tools are needed to design large sets of barcodes to allow construction of large barcoded mammalian libraries such as shRNA libraries. Here we report a framework for designing large sets of orthogonal barcode probes. We demonstrate the utility of this framework by designing 240,000 barcode probes and testing their performance by hybridization. From the test hybridizations, we also discovered new probe design rules that significantly reduce cross-hybridization after their introduction into the framework of the algorithm. These rules should improve the performance of DNA microarray probe designs for many applications.
Design of 240,000 orthogonal 25mer DNA barcode probes
Xu, Qikai; Schlabach, Michael R.; Hannon, Gregory J.; Elledge, Stephen J.
2009-01-01
DNA barcodes linked to genetic features greatly facilitate screening these features in pooled formats using microarray hybridization, and new tools are needed to design large sets of barcodes to allow construction of large barcoded mammalian libraries such as shRNA libraries. Here we report a framework for designing large sets of orthogonal barcode probes. We demonstrate the utility of this framework by designing 240,000 barcode probes and testing their performance by hybridization. From the test hybridizations, we also discovered new probe design rules that significantly reduce cross-hybridization after their introduction into the framework of the algorithm. These rules should improve the performance of DNA microarray probe designs for many applications. PMID:19171886
Systems and methods for laser assisted sample transfer to solution for chemical analysis
Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.
2014-06-03
Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.
Systems and methods for laser assisted sample transfer to solution for chemical analysis
Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.
2015-09-29
Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.
Systems and methods for laser assisted sample transfer to solution for chemical analysis
Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S
2013-08-27
Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.
Spared Anterograde Memory for Shock-Probe Fear Conditioning After Inactivation of the Amygdala
Lehmann, Hugo; Treit, Dallas; Parent, Marise B.
2003-01-01
Previous studies have shown that amygdala lesions impair avoidance of an electrified probe. This finding has been interpreted as indicating that amygdala lesions reduce fear. It is unclear, however, whether amygdala-lesioned rats learn that the probe is associated with shock. If the lesions prevent the formation of this association, then pretraining reversible inactivation of the amygdala should impair both acquisition and retention performance. To test this hypothesis, the amygdala was inactivated (tetrodotoxin; TTX; 1 ng/side) before a shock-probe acquisition session, and retention was tested 4 d later. The data indicated that, compared with rats infused with vehicle, rats infused with TTX received more shocks during the acquisition session, but more importantly, were not impaired on the retention test. In Experiment 2, we assessed whether the spared memory on the retention test was caused by overtraining during acquisition. We used the same procedure as in Experiment 1, with the exception that the number of shocks the rats received during the acquisition session was limited to four. Again the data indicated that amygdala inactivation did not impair performance on the retention test. These results indicate that amygdala inactivation does not prevent the formation of an association between the shock and the probe and that shock-probe deficits during acquisition likely reflect the amygdala's involvement in other processes. PMID:12888544
Methodology Development for the Reconstruction of the ESA Huygens Probe Entry and Descent Trajectory
NASA Astrophysics Data System (ADS)
Kazeminejad, B.
2005-01-01
The European Space Agency's (ESA) Huygens probe performed a successful entry and descent into Titan's atmosphere on January 14, 2005, and landed safely on the satellite's surface. A methodology was developed, implemented, and tested to reconstruct the Huygens probe trajectory from its various science and engineering measurements, which were performed during the probe's entry and descent to the surface of Titan, Saturn's largest moon. The probe trajectory reconstruction is an essential effort that has to be done as early as possible in the post-flight data analysis phase as it guarantees a correct and consistent interpretation of all the experiment data and furthermore provides a reference set of data for "ground-truthing" orbiter remote sensing measurements. The entry trajectory is reconstructed from the measured probe aerodynamic drag force, which also provides a means to derive the upper atmospheric properties like density, pressure, and temperature. The descent phase reconstruction is based upon a combination of various atmospheric measurements such as pressure, temperature, composition, speed of sound, and wind speed. A significant amount of effort was spent to outline and implement a least-squares trajectory estimation algorithm that provides a means to match the entry and descent trajectory portions in case of discontinuity. An extensive test campaign of the algorithm is presented which used the Huygens Synthetic Dataset (HSDS) developed by the Huygens Project Scientist Team at ESA/ESTEC as a test bed. This dataset comprises the simulated sensor output (and the corresponding measurement noise and uncertainty) of all the relevant probe instruments. The test campaign clearly showed that the proposed methodology is capable of utilizing all the relevant probe data, and will provide the best estimate of the probe trajectory once real instrument measurements from the actual probe mission are available. As a further test case using actual flight data the NASA Mars Pathfinder entry and descent trajectory and the space craft attitude was reconstructed from the 3-axis accelerometer measurements which are archived on the Planetary Data System. The results are consistent with previously published reconstruction efforts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, Scott D.; He, Lijian; Wahl, Jon H.
2012-08-30
This study provides a preliminary evaluation of the Field and Laboratory Emission Cell (FLEC) for its suitability for sampling building materials for toxic compounds and their associated impurities and residues that might remain after a terrorist chemical attack. Chemical warfare (CW) agents and toxic industrial chemicals were represented by a range of test probes that included CW surrogates. The test probes encompassed the acid-base properties, volatilities, and polarities of the expected chemical agents and residual compounds. Results indicated that dissipation of the test probes depended heavily on the underlying material. Near complete dissipation of almost all test probes occurred frommore » galvanized stainless steel within 3.0 hrs, whereas far stronger retention with concomitant slower release was observed for vinyl composition floor tiles. The test probes displayed immediated permanence on Teflon. FLEC sampling was further evaluated by profiling residues remaining after the evaporation of 2-chloroethyl ethyl sulfide, a sulfur mustard simulant. This study lays the groundwork for the eventual goal of applying this sampling approach for collection of forensic attribution signatures that remain after a terrorist chemical attack.« less
Five-Hole Flow Angle Probe Calibration for the NASA Glenn Icing Research Tunnel
NASA Technical Reports Server (NTRS)
Gonsalez, Jose C.; Arrington, E. Allen
1999-01-01
A spring 1997 test section calibration program is scheduled for the NASA Glenn Research Center Icing Research Tunnel following the installation of new water injecting spray bars. A set of new five-hole flow angle pressure probes was fabricated to properly calibrate the test section for total pressure, static pressure, and flow angle. The probes have nine pressure ports: five total pressure ports on a hemispherical head and four static pressure ports located 14.7 diameters downstream of the head. The probes were calibrated in the NASA Glenn 3.5-in.-diameter free-jet calibration facility. After completing calibration data acquisition for two probes, two data prediction models were evaluated. Prediction errors from a linear discrete model proved to be no worse than those from a full third-order multiple regression model. The linear discrete model only required calibration data acquisition according to an abridged test matrix, thus saving considerable time and financial resources over the multiple regression model that required calibration data acquisition according to a more extensive test matrix. Uncertainties in calibration coefficients and predicted values of flow angle, total pressure, static pressure. Mach number. and velocity were examined. These uncertainties consider the instrumentation that will be available in the Icing Research Tunnel for future test section calibration testing.
Agersborg, Sally; Mixon, Christopher; Nguyen, Thanh; Aithal, Sramila; Sudarsanam, Sucha; Blocker, Forrest; Weiss, Lawrence; Gasparini, Robert; Jiang, Shiping; Chen, Wayne; Hess, Gregory; Albitar, Maher
2018-03-22
While HER2 testing is well established in directing appropriate treatment for breast cancer, a small percentage of cases show equivocal results by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Alternative probes may be used in equivocal cases. We present a single community-based institution's experience in further evaluating these cases. Between 2014 and 2016, 4255 samples were submitted for HER2 amplification testing by alternative probes, TP53, RAI1, and RARA. Of the patients tested by FISH, 505/3908 (12.9%) also had IHC data. Most (73.9%) FISH equivocal cases remained equivocal after IHC testing. However, 50.5% of equivocal cases were classified as HER2 amplified by alternative probes. Most cases were positive by more than one probe: 78% of positive cases by RAI1 and 73.9% by TP53. There was a significant difference between IHC and FISH alternative testing (p < 0.0001) among the equivocal cases by conventional FISH testing, 44% of IHC negative cases became positive while 36% of the positive IHC cases became negative by alternative FISH testing. Available data showed that 41% of patients were treated with palbociclib and were positive by alternative FISH. The prevalence of double HER2 equivocal cases and the discrepancy between IHC and alternative FISH testing suggest that FISH alternative testing using both RAI1 and TP53 probes is necessary for conclusive classification. Because almost half of FISH equivocal cases converted to HER2 amplified upon alternative testing, clinical studies to determine the benefit of anti-HER2 therapy in these patients are urgently needed.
Design of piezoelectric probe for measurement of longitudinal and shear components of elastic wave
NASA Astrophysics Data System (ADS)
Aoyanagi, Masafumi; Wakatsuki, Naoto; Mizutani, Koichi; Ebihara, Tadashi
2017-07-01
We focus on ultrasonic probes for nondestructive tests and evaluation. Transient characteristics of probes are important for nondestructive tests such as the pulse echo method. We previously reported the principle of measurement using a piezoelectric probe with triaxial sensitivities. In the results, it was calculated that the probe could transmit and receive particle displacement which contains normal and tangential components. It was confirmed that the probe had sensitivities in triaxial directions. However, its performance in terms of frequency and transient characteristics has not been evaluated. The purpose of this study is to design a probe by changing its shape to obtain better performance. The transient characteristics of probes in longitudinal and shear driving were evaluated by the inverse Fourier transformation of frequency responses of longitudinal and shear components, using the two-dimensional finite element method. As a result, the sensitivities at the dips of frequency characteristics increased when using our probe compared with those measured using conventional probes in longitudinal and shear driving. Hence, the performance in terms of the frequency response was improved by more than 3 dB under the conditions in this simulation. Also, the pulse width of impulse response was decreased by half compared with that of probes with conventional shapes.
Concrete probe-strength study : final report.
DOT National Transportation Integrated Search
1969-12-01
The Windsor probe - test system was evaluated for determining compressive strength of concrete by comparing probe strengths against cylinder and core strengths from both laboratory and field-poured concrete. Advantages and disadvantages of this syste...
Diode-laser-based therapy device
NASA Astrophysics Data System (ADS)
Udrea, Mircea V.; Nica, Adriana S.; Florian, Mariana; Poenaru, Daniela; Udrea, Gabriela; Lungeanu, Mihaela; Sporea, Dan G.; Vasiliu, Virgil V.; Vieru, Roxana
2004-10-01
A new therapy laser device is presented. The device consists of a central unit and different types of laser probes. The laser probe model SL7-650 delivers seven red (650 nm), 5 mW diode lasers convergent beams. The beams converge at about 30 cm in front of the laser probe and the irradiated area might be varied by simple displacement of the laser probe with respect to the target. The laser probe SL1-808 emits single infrared laser beam up to 500 mW. The efficiency of the use of this device in physiotherapy, and rheumatology, has been put into evidence after years of testing. Dermatology and microsurgery are users of infrared powerful laser probes. The device has successfully passed technical and clinical tests in order to be certified. The laser device design and some medical results are given.
Pitot-probe displacement in a supersonic turbulent boundary layer
NASA Technical Reports Server (NTRS)
Allen, J. M.
1972-01-01
Eight circular pitot probes ranging in size from 2 to 70 percent of the boundary-layer thickness were tested to provide experimental probe displacement results in a two-dimensional turbulent boundary layer at a nominal free-stream Mach number of 2 and unit Reynolds number of 8 million per meter. The displacement obtained in the study was larger than that reported by previous investigators in either an incompressible turbulent boundary layer or a supersonic laminar boundary layer. The large probes indicated distorted Mach number profiles, probably due to separation. When the probes were small enough to cause no appreciable distortion, the displacement was constant over most of the boundary layer. The displacement in the near-wall region decreased to negative displacement in some cases. This near-wall region was found to extend to about one probe diameter from the test surface.
High temperature integrated ultrasonic shear and longitudinal wave probes
NASA Astrophysics Data System (ADS)
Ono, Y.; Jen, C.-K.; Kobayashi, M.
2007-02-01
Integrated ultrasonic shear wave probes have been designed and developed using a mode conversion theory for nondestructive testing and characterization at elevated temperatures. The probes consisted of metallic substrates and high temperature piezoelectric thick (>40μm) films through a paint-on method. Shear waves are generated due to mode conversion from longitudinal to shear waves because of reflection inside the substrate having a specific shape. A novel design scheme is proposed to reduce the machining time of substrates and thick film fabrication difficulty. A probe simultaneously generating and receiving both longitudinal and shear waves is also developed and demonstrated. In addition, a shear wave probe using a clad buffer rod consisting of an aluminum core and stainless steel cladding has been developed. All the probes were tested and successfully operated at 150°C.
Spacecraft-level verification of the Van Allen Probes' RF communication system
NASA Astrophysics Data System (ADS)
Crowne, M. J.; Srinivasan, D.; Royster, D.; Weaver, G.; Matlin, D.; Mosavi, N.
This paper presents the verification process, lessons learned, and selected test results of the radio frequency (RF) communication system of the Van Allen Probes, formerly known as the Radiation Belt Storm Probes (RBSP). The Van Allen Probes mission is investigating the doughnut-shaped regions of space known as the Van Allen radiation belts where the Sun interacts with charged particles trapped in Earth's magnetic field. Understanding this dynamic area that surrounds our planet is important to improving our ability to design spacecraft and missions for reliability and astronaut safety. The Van Allen Probes mission features two nearly identical spacecraft designed, built, and operated by the Johns Hopkins University Applied Physics Laboratory (JHU/APL) for the National Aeronautics and Space Administration (NASA). The RF communication system features the JHU/APL Frontier Radio. The Frontier Radio is a software-defined radio (SDR) designed for spaceborne communications, navigation, radio science, and sensor applications. This mission marks the first spaceflight usage of the Frontier Radio. RF ground support equipment (RF GSE) was developed using a ground station receiver similar to what will be used in flight and whose capabilities provided clarity into RF system performance that was previously not obtained until compatibility testing with the ground segments. The Van Allen Probes underwent EMC, acoustic, vibration, and thermal vacuum testing at the environmental test facilities at APL. During this time the RF communication system was rigorously tested to ensure optimal performance, including system-level testing down to threshold power levels. Compatibility tests were performed with the JHU/APL Satellite Communication Facility (SCF), the Universal Space Network (USN), and the Tracking and Data Relay Satellite System (TDRSS). Successful completion of this program as described in this paper validated the design of the system and demonstrated that it will be able to me- t all of the Van Allen Probes's communications requirements with its intended ground segments.
Nakhoul, Georges N; Hickner, John
2013-06-01
Rapid antigen detection tests (RADT) are commonly used to guide appropriate antibiotic treatment of group A beta-hemolytic streptococcal (GABHS) pharyngitis. In adults, there is controversy about the need for routine backup testing of negative RADT. Estimate the costs and benefits in adults of routine backup testing by DNA Gen-probe of negative RADT (Acceava). Observational follow-up study. All patients aged 18 years and older visiting a Cleveland Clinic generalist physician in 2009 and 2010 with a visit diagnosis of acute pharyngitis (ICD codes 462, 034.0). The patients were identified using the Cleveland Clinic Epic Clarity database. We determined the proportion of false negative RADT, antibiotic prescription patterns and rate of serious suppurative complications within 30 days of the office visit. Of 25,130 patients with acute pharyngitis, 19% had no testing and 81% were tested. Of the 15,555 patients that had a negative RADT and follow-up DNA probe, 6% had a positive DNA probe. Of the 953 patients who had a negative RADT and a positive DNA strep probe, 48% received an antibiotic prescription at the time of the visit and 51% received an antibiotic prescription after an average of 2.3 days. Only one patient with a negative RADT and no follow-up DNA probe developed a peritonsillar abscess. Overall, of the 15,555 DNA probes performed, management was altered in only 3% of the patients at a total cost of $1,757,715. Fifty-six percent received an antibiotic while only 19.5% had a confirmed strep throat diagnosis. The false negative rate of Acceava RADT for the diagnosis of GABHS pharyngitis was 6%. We question the benefit of routine DNA probe backup testing in adults because of its substantial cost, an average delay in antibiotic prescribing of over 2 days, and because suppurative complications are very uncommon. We found a high rate of inappropriate antibiotic prescribing.
Design and test of voltage and current probes for EAST ICRF antenna impedance measurement
NASA Astrophysics Data System (ADS)
Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG
2018-04-01
On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L < 1.5 Ω, which implies that the power loss cannot be neglected at high VSWR. As the factors that give rise to the deviation of coupling resistance calculation, the phase measurement error is the more significant factor leads to deleterious results rather than the amplitude measurement error. To exclude the possible ingredients that may lead to phase measurement error, the phase detector can be calibrated in steady L-mode scenario and then use the calibrated data for calculation under H-mode cases in EAST experiments.
Correction analysis for a supersonic water cooled total temperature probe tested to 1370 K
NASA Technical Reports Server (NTRS)
Lagen, Nicholas T.; Seiner, John M.
1991-01-01
The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.
Parker Solar Probe Light Bar Test
2018-06-05
In the Astrotech processing facility in Titusville, Florida, near NASA's Kennedy Space Center, on Tuesday, June 5, 2018, technicians and engineers perform light bar testing on NASA's Parker Solar Probe. The Parker Solar Probe will launch on a United Launch Alliance Delta IV Heavy rocket from Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida no earlier than Aug. 4, 2018. The mission will perform the closest-ever observations of a star when it travels through the Sun's atmosphere, called the corona. The probe will rely on measurements and imaging to revolutionize our understanding of the corona and the Sun-Earth connection.
Auditory enhancement of increments in spectral amplitude stems from more than one source.
Carcagno, Samuele; Semal, Catherine; Demany, Laurent
2012-10-01
A component of a test sound consisting of simultaneous pure tones perceptually "pops out" if the test sound is preceded by a copy of itself with that component attenuated. Although this "enhancement" effect was initially thought to be purely monaural, it is also observable when the test sound and the precursor sound are presented contralaterally (i.e., to opposite ears). In experiment 1, we assessed the magnitude of ipsilateral and contralateral enhancement as a function of the time interval between the precursor and test sounds (10, 100, or 600 ms). The test sound, randomly transposed in frequency from trial to trial, was followed by a probe tone, either matched or mismatched in frequency to the test sound component which was the target of enhancement. Listeners' ability to discriminate matched probes from mismatched probes was taken as an index of enhancement magnitude. The results showed that enhancement decays more rapidly for ipsilateral than for contralateral precursors, suggesting that ipsilateral enhancement and contralateral enhancement stem from at least partly different sources. It could be hypothesized that, in experiment 1, contralateral precursors were effective only because they provided attentional cues about the target tone frequency. In experiment 2, this hypothesis was tested by presenting the probe tone before the precursor sound rather than after the test sound. Although the probe tone was then serving as a frequency cue, contralateral precursors were again found to produce enhancement. This indicates that contralateral enhancement cannot be explained by cuing alone and is a genuine sensory phenomenon.
Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps
NASA Technical Reports Server (NTRS)
Goekcen, Tahir; Alunni, Antonella I.
2016-01-01
This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.
THE EVOLUTION OF ASTEROIDS IN THE JUMPING-JUPITER MIGRATION MODEL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roig, Fernando; Nesvorný, David, E-mail: froig@on.br, E-mail: davidn@boulder.swri.edu
In this work, we investigate the evolution of a primordial belt of asteroids, represented by a large number of massless test particles, under the gravitational effect of migrating Jovian planets in the framework of the jumping-Jupiter model. We perform several simulations considering test particles distributed in the Main Belt, as well as in the Hilda and Trojan groups. The simulations start with Jupiter and Saturn locked in the mutual 3:2 mean motion resonance plus three Neptune-mass planets in a compact orbital configuration. Mutual planetary interactions during migration led one of the Neptunes to be ejected in less than 10 Myrmore » of evolution, causing Jupiter to jump by about 0.3 AU in semimajor axis. This introduces a large-scale instability in the studied populations of small bodies. After the migration phase, the simulations are extended over 4 Gyr, and we compare the final orbital structure of the simulated test particles to the current Main Belt of asteroids with absolute magnitude H < 9.7. The results indicate that, in order to reproduce the present Main Belt, the primordial belt should have had a distribution peaked at ∼10° in inclination and at ∼0.1 in eccentricity. We discuss the implications of this for the Grand Tack model. The results also indicate that neither primordial Hildas, nor Trojans, survive the instability, confirming the idea that such populations must have been implanted from other sources. In particular, we address the possibility of implantation of Hildas and Trojans from the Main Belt population, but find that this contribution should be minor.« less
An Experimental Investigation Into the Temperature Profile of a Compliant Foil Air Bearing
NASA Technical Reports Server (NTRS)
Radil, Kevin; Zeszotek, Michelle
2004-01-01
A series of tests was performed to determine the internal temperature profile in a compliant bump-type foil journal air bearing operating at room temperature under various speeds and load conditions. The temperature profile was collected by instrumenting a foil bearing with nine, type K thermocouples arranged in the center and along the bearing s edges in order to measure local temperatures and estimate thermal gradients in the axial and circumferential directions. To facilitate the measurement of maximum temperatures from viscous shearing in the air film, the thermocouples were tack welded to the backside of the bumps that were in direct contact with the top foil. The mating journal was coated with a high temperature solid lubricant that, together with the bearing, underwent high temperature start-stop cycles to produce a smooth, steady-state run-in surface. Tests were conducted at speeds from 20 to 50 krpm and loads ranging from 9 to 222 N. The results indicate that, over the conditions tested, both journal rotational speed and radial load are responsible for heat generation with speed playing a more significant role in the magnitude of the temperatures. The temperature distribution was nearly symmetric about the bearing center at 20 and 30 krpm but became slightly skewed toward one side at 40 and 50 krpm. Surprisingly, the maximum temperatures did not occur at the bearing edge where the minimum film thickness is expected but rather in the middle of the bearing where analytical investigations have predicted the air film to be much thicker. Thermal gradients were common during testing and were strongest in the axial direction from the middle of the bearing to its edges, reaching 3.78 8C/mm. The temperature profile indicated the circumferential thermal gradients were negligible.
NASA Technical Reports Server (NTRS)
Porro, A. Robert
2001-01-01
A series of dynamic flow field pressure probes were developed for use in large-scale supersonic wind tunnels at NASA Glenn Research Center. These flow field probes include pitot, static, and five-hole conical pressure probes that are capable of capturing fast acting flow field pressure transients that occur on a millisecond time scale. The pitot and static probes can be used to determine local Mach number time histories during a transient event. The five-hole conical pressure probes are used primarily to determine local flow angularity, but can also determine local Mach number. These probes were designed, developed, and tested at the NASA Glenn Research Center. They were also used in a NASA Glenn 10- by 10-Foot Supersonic Wind Tunnel (SWT) test program where they successfully acquired flow field pressure data in the vicinity of a propulsion system during an engine compressor stall and inlet unstart transient event. Details of the design, development, and subsequent use of these probes are discussed in this report.
NASA Technical Reports Server (NTRS)
Rudoff, R. C.; Bachalo, E. J.; Bachalo, W. D.; Oldenburg, J. R.
1992-01-01
The design, development, and testing of an icing cloud droplet sizing probe based upon the Phase Doppler Particle Analyzer (PDPA) are discussed. This probe is an in-situ laser interferometry based single particle measuring device capable of determining size distributions. The probe is designed for use in harsh environments such as icing tunnels and natural icing clouds. From the measured size distribution, Median Volume Diameter (MVD) and Liquid Water Content (LWC) may be determined. Both the theory of measurement and the mechanical aspects of the probe design and development are discussed. The MVD results from the probe are compared to an existing calibration based upon different instruments in a series of tests in the NASA Lewis Icing Research Tunnel. Agreement between the PDPA probe and the existing calibration is close for MVDs between 15 to 30 microns, but the PDPA results are considerably smaller for MVDs under 15 microns.
NASA Technical Reports Server (NTRS)
Darcy, Eric; Strangways, Brad
2003-01-01
Contents include the following: 1. Introduction: What is the (Floating Potential Probe) FPP? Why was NiMH battery selected? Haw well would crimped seal cell performed in long term vacuum exposure? 2. Verification tests: Battery description. Test methods. Results. Main findings. FPP status.
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... intersection of the head midsagittal plane and the transverse plane which is perpendicular to the Z axis of the... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at... in the dummy's midsagittal plane. (4) Guide the test probe during impact so that there is no...
Electromechanical Apparatus Measures Residual Stress
NASA Technical Reports Server (NTRS)
Chern, Engmin J.; Flom, Yury
1993-01-01
Nondestructive test exploits relationship between stress and eddy-current-probe resistance. Yields data on residual stress or strain in metal tension/compression specimen (stress or strain remaining in specimen when no stress applied from without). Apparatus is assembly of commercial equipment: tension-or-compression testing machine, eddy-current probe, impedance gain-and-phase analyzer measuring impedance of probe coil, and desktop computer, which controls other equipment and processes data received from impedance gain-and-phase analyzer.
49 CFR 572.124 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... by a test probe conforming to section 572.127(a) at 6.71 ±0.12 m/s (22.0 ±0.4 ft/s) according to the..., the peak force, measured by the probe in accordance with section 572.127, shall not be less than 1150... centerline of the probe coincides with the midsagittal plane of the dummy within ±2.5 mm (0.1 in) and is 12.7...
49 CFR 572.124 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... by a test probe conforming to section 572.127(a) at 6.71 ±0.12 m/s (22.0 ±0.4 ft/s) according to the..., the peak force, measured by the probe in accordance with section 572.127, shall not be less than 1150... centerline of the probe coincides with the midsagittal plane of the dummy within ±2.5 mm (0.1 in) and is 12.7...
49 CFR 572.124 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... by a test probe conforming to section 572.127(a) at 6.71 ±0.12 m/s (22.0 ±0.4 ft/s) according to the..., the peak force, measured by the probe in accordance with section 572.127, shall not be less than 1150... centerline of the probe coincides with the midsagittal plane of the dummy within ±2.5 mm (0.1 in) and is 12.7...
49 CFR 572.124 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... by a test probe conforming to section 572.127(a) at 6.71 ±0.12 m/s (22.0 ±0.4 ft/s) according to the..., the peak force, measured by the probe in accordance with section 572.127, shall not be less than 1150... centerline of the probe coincides with the midsagittal plane of the dummy within ±2.5 mm (0.1 in) and is 12.7...
Electrolyzer assembly method and system
Swala, Dana Ray; Bourgeois, Richard Scott; Paraszczak, Steven; Buckley, Donald Joseph
2017-05-23
The present techniques provide a novel electrolyzer and methods for welding components of such electrolyzers. The techniques may use conductors, such as resistance wires, placed in paths around the internal structural features and edges of the components. The conductors may be incorporated into the components during manufacture by injection molding, or other molding techniques, or may be tacked or otherwise applied to the surface of the components after manufacture. When current, a field or other excitation is applied to the conductors, the plastic surrounding the wire is melted. If this plastic is in direct contact with an adjoining component, a strong, hermetic seal may be formed between the two components, including the internal structural features.
A method for remote sounding of a bottom relief of water objects with using GPS
NASA Astrophysics Data System (ADS)
Mamontova, L. S.
2014-12-01
The no-fly automated system of small rivers' depth's measurement which is based on a combination of a differential method GPS-definition of the pro-measured vessel's coordinates both the method of depth's measurement with sonic depth finder and the method of the vessel's management was examined in this article.On the central station the digital card with a relief for a pro-measured zone of the reservoir is formed and the position of a pro-measured vessel on the tacks is controlled thanks to the coordinates of a pro-measured vessel and depth's measurements with sonic depth finder.The offered system allows to raise the level of depth's pro-measured works.
Solventless LARC-160 Polyimide Matrix Resin. [applied for use in aerospace engineering
NASA Technical Reports Server (NTRS)
Stclair, T. L.; Jewell, R. A.
1978-01-01
The addition polyimide, LARC-160, which was originally synthesized from low cost liquid monomers as a laminating resin in ethanol, was prepared as a solventless, high viscosity, neat liquid resin. The resin was processed by hot-melt coating techniques into graphite prepreg with excellent tack and drape. Comparable data on graphite reinforced laminates made from solvent-coated and various hot-melt coated prepreg were generated. LARC-160, because of its liquid nature, can be easily autoclave processed to produce low void laminates. Liquid chromatographic fingerprints indicate good reaction control on resin scale ups. Minor changes in monomer ratios were also made to improve the thermal aging performance of graphite laminates.
NASA Technical Reports Server (NTRS)
Lagen, Nicholas; Seiner, John M.
1990-01-01
Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.
Acoustic reflex on newborns: the influence of the 226 and 1,000 Hz probes.
Jacob-Corteletti, Lilian Cássia Bórnia; Duarte, Josilene Luciene; Zucki, Fernanda; Mariotto, Luciane Domingues Figueiredo; Lauris, José Roberto Pereira; Alvarenga, Kátia de Freitas
2015-01-01
To analyze the occurrence of acoustic reflex and its threshold on newborns using the 226 and 1,000 Hz probes. Thirty-six newborns with "PASS" results in newborn hearing screening and tympanogram with one or two peaks for both probe tones were included. Group I comprised 20 full-term newborns without risk indicator for hearing loss, and Group II comprised 16 newborns with at least one risk indicator. The study about ipsilateral acoustic reflex thresholds was conducted in 500, 1,000, 2,000, and 4,000 Hz. The groups presented the acoustic reflex thresholds between 50 and 100 dB for both probe tones. In the comparison between the probes, there were differences in all frequencies evaluated in Group I, with the lowest threshold mean for the 1,000 Hz probe. In Group II, differences were detected at 2,000 Hz. The mean acoustic reflex thresholds were similar in both groups for the 226 Hz probe. There was a difference for the 1,000 Hz probe in all tested frequencies. The percentage of response was higher in both groups for the 1,000 Hz probe. The kappa test showed extremely poor agreement in the comparison of results between both probes. The occurrence of acoustic reflex was higher in newborns and its thresholds were lower with the 1,000 Hz probe both for healthy newborns and for newborns at risk.
Detection of Fatigue Cracks at Rivets with Self-Nulling Probe
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min
1994-01-01
A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further
Kim, Hannah; Ricketts, Todd A
2013-01-01
To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). Probe-microphone measurements were completed for two mini-behind-the-ear (BTE) hearing aids which were coupled to the ear using open and closed eartips via thin (0.9 mm) tubing. Before probe-microphone testing, the gain of each of the test hearing aids was programmed using an artificial ear simulator (IEC 711) and a Knowles Electronic Manikin for Acoustic Research to match the National Acoustic Laboratories-Non-Linear, version 1 targets for one of two separate hearing loss configurations using an Audioscan Verifit. No further adjustments were made, and the same amplifier gain was used within each hearing aid across both eartip configurations and all participants. Probe-microphone testing included real-ear occluded response (REOR) and REAR measures using the Verifit's standard speech signal (the carrot passage) presented at 65 dB sound pressure level (SPL). Two repeated probe-microphone measures were made for each participant with the probe-tube and hearing aid removed and repositioned between each trial in order to assess intrasubject measurement variability. These procedures were repeated using both open and closed domes. Thirty-two children, ages ranging from 4 to 14 yr. The test-retest standard deviations for open and closed measures did not exceed 4 dB at any frequency. There was also no significant difference between the open (stored equalization) and closed (concurrent equalization) methods. Reliability was particularly similar in the high frequencies and was also quite similar to that reported in previous research. There was no correlation between reliability and age, suggesting high reliability across all ages evaluated. The findings from this study suggest that reliable probe-microphone measurements are obtainable on children 4 yr and older for both traditional unvented and open-canal hearing aid fittings. These data suggest that clinicians should not avoid fitting open technology to children as young as 4 y because of concerns regarding the reliability of verification techniques. American Academy of Audiology.
Melting probes revisited - Ice penetration experiments under Mars surface pressure conditions
NASA Astrophysics Data System (ADS)
Kömle, Norbert I.; Tiefenbacher, Patrick; Weiss, Peter; Bendiukova, Anastasiia
2018-07-01
Melting probes as vehicles to explore terrestrial ice sheets have been designed and applied successfully since the early 1960's. Later on, in the 1990's, various proposals were made to apply such probes also as a means to explore ice sheets on other bodies of the solar system, e.g. Jupiter's icy satellite Europa or the ice caps of Mars. For this type of subsurface probes the name cryobot has become common. We review both early developments and more recent efforts to develop probes for application in planetary environments, i.e. under low pressures and low temperatures. The current state of art as well as the pros and cons of the different concepts hitherto considered are described. While many tests with various probes have been done in terrestrial environments, experiments under low surface pressure conditions are rare. Therefore, we report here on lab tests with a simple melting probe under the range of pressure and temperature conditions that would be encountered on the surface of Mars and compare them with corresponding tests under a much lower gas pressure, possibly representative for icy satellites. The contribution of evaporation during the melting and its variation with surface pressure is also considered. All surface pressure measurements that have been performed on Mars up to now indicate a surface pressure above the water triple point pressure (612 Pa). This means that water ice always transforms into the liquid phase when warmed up to 0°C, before it evaporates into the ambient atmosphere. The temporary existence of the liquid phase around the heated tip of the cryobot allows good thermal conductance between probe and surrounding ice, which is an important pre-requisite for efficient melt penetration. Our experiments indicate that under all possible Mars surface pressures the liquid phase is present when the probe is heated up. This finding confirms experimentally that a probe as it was proposed by Paige (1992) for in situ exploration of the Mars north polar layers would work in the expected way, although the penetration velocity must be expected be lower than under Earth pressure conditions. A test with the same probe, but under an almost two orders of magnitude lower gas pressure than on Mars, still indicates the temporary existence of the liquid phase in the contact region between the probe and the surrounding ice.
Ullrich, Thomas; Ermantraut, Eugen; Schulz, Torsten; Steinmetzer, Katrin
2012-01-01
Background State of the art molecular diagnostic tests are based on the sensitive detection and quantification of nucleic acids. However, currently established diagnostic tests are characterized by elaborate and expensive technical solutions hindering the development of simple, affordable and compact point-of-care molecular tests. Methodology and Principal Findings The described competitive reporter monitored amplification allows the simultaneous amplification and quantification of multiple nucleic acid targets by polymerase chain reaction. Target quantification is accomplished by real-time detection of amplified nucleic acids utilizing a capture probe array and specific reporter probes. The reporter probes are fluorescently labeled oligonucleotides that are complementary to the respective capture probes on the array and to the respective sites of the target nucleic acids in solution. Capture probes and amplified target compete for reporter probes. Increasing amplicon concentration leads to decreased fluorescence signal at the respective capture probe position on the array which is measured after each cycle of amplification. In order to observe reporter probe hybridization in real-time without any additional washing steps, we have developed a mechanical fluorescence background displacement technique. Conclusions and Significance The system presented in this paper enables simultaneous detection and quantification of multiple targets. Moreover, the presented fluorescence background displacement technique provides a generic solution for real time monitoring of binding events of fluorescently labelled ligands to surface immobilized probes. With the model assay for the detection of human immunodeficiency virus type 1 and 2 (HIV 1/2), we have been able to observe the amplification kinetics of five targets simultaneously and accommodate two additional hybridization controls with a simple instrument set-up. The ability to accommodate multiple controls and targets into a single assay and to perform the assay on simple and robust instrumentation is a prerequisite for the development of novel molecular point of care tests. PMID:22539973
Measuring liquid density using Archimedes' principle
NASA Astrophysics Data System (ADS)
Hughes, Stephen W.
2006-09-01
A simple technique is described for measuring absolute and relative liquid density based on Archimedes' principle. The technique involves placing a container of the liquid under test on an electronic balance and suspending a probe (e.g. a glass marble) attached to a length of line beneath the surface of the liquid. If the volume of the probe is known, the density of liquid is given by the difference between the balance reading before and after immersion of the probe divided by the volume of the probe. A test showed that the density of water at room temperature could be measured to an accuracy and precision of 0.01 ± 0.1%. The probe technique was also used to measure the relative density of milk, Coca-Cola, fruit juice, olive oil and vinegar.
Development of the STPX Spheromak System
NASA Astrophysics Data System (ADS)
Williams, R. L.; Clark, J.; Weatherford, C. A.
2015-11-01
The progress made in starting up the STPX Spheromak system, which is now installed at the Florida A&M University, is reviewed. Experimental, computational and theoretical activities are underway. The control system for firing the magnetized coaxial plasma gun and for collecting data from the diagnostic probes, based on LabView, is being tested and adapted. Preliminary results of testing the installed magnetic field probes, Langmuir triple probes, cylindrical ion probes, and optical diagnostics will be discussed. Progress in modeling this spheromak using simulation codes, such as NIMROD, will be discussed. Progress in investigating the use of algebraic topology to describe this spheromak will be reported.
NASA Technical Reports Server (NTRS)
Russell, John M.
1993-01-01
Many helium mass spectrometer leak detectors at KSC employ sampling systems that feature hand held sniffer probes. Authors of general leakage-testing literature recommend sniffer probes for leak location but not for quantitative leakage measurement. Their use in the latter application at KSC involves assumptions that may be subtle. The purpose of the research effort reported herein was to establish the significance of indicated leak rates displayed by sniffer-probe equipped leak detectors and to determine whether the use of alternative hardware or testing procedures may reduce the uncertainty of leakage measurements made with them. The report classifies probe-type sampling systems for helium leak detectors according to their internal plumbing (direct or branched), presents a basic analysis of the fluid dynamics in the sampling system in the branched-conduit case, describes the usual test method for measuring the internal supply-to-sample flowrate ratio (a.k.a permeation ratio), and describes a concept for a sponge-tipped probe whose external supply-to-sample flowrate ratio promises to be lower than that of a simple-ended probe. One conclusion is that the main source of uncertainty in the use of probe-type sampling systems for leakage measurement is uncertainty in the external supply-to-sample flowrate ratio. In contrast, the present method for measuring the internal supply-to-sample flowrate ratio is quantitative and satisfactory. The implication is that probes of lower external supply-to-sample flowrate ratio must be developed before this uncertainty may be reduced significantly.
Ferromagnetic resonance probe liftoff suppression apparatus
Davis, Thomas J.; Tomeraasen, Paul L.
1985-01-01
A liftoff suppression apparatus utilizing a liftoff sensing coil to sense the amount a ferromagnetic resonance probe lifts off the test surface during flaw detection and utilizing the liftoff signal to modulate the probe's field modulating coil to suppress the liftoff effects.
Aragón-Sánchez, J; Lipsky, Benjamin A; Lázaro-Martínez, J L
2011-02-01
To investigate the accuracy of the sequential combination of the probe-to-bone test and plain X-rays for diagnosing osteomyelitis in the foot of patients with diabetes. We prospectively compiled data on a series of 338 patients with diabetes with 356 episodes of foot infection who were hospitalized in the Diabetic Foot Unit of La Paloma Hospital from 1 October 2002 to 31 April 2010. For each patient we did a probe-to-bone test at the time of the initial evaluation and then obtained plain X-rays of the involved foot. All patients with positive results on either the probe-to-bone test or plain X-ray underwent an appropriate surgical procedure, which included obtaining a bone specimen that was processed for histology and culture. We calculated the sensitivity, specificity, predictive values and likelihood ratios of the procedures, using the histopathological diagnosis of osteomyelitis as the criterion standard. Overall, 72.4% of patients had histologically proven osteomyelitis, 85.2% of whom had positive bone culture. The performance characteristics of both the probe-to-bone test and plain X-rays were excellent. The sequential diagnostic approach had a sensitivity of 0.97, specificity of 0.92, positive predictive value of 0.97, negative predictive value of 0.93, positive likelihood ratio of 12.8 and negative likelihood ratio of 0.02. Only 6.6% of patients with negative results on both diagnostic studies had osteomyelitis. Clinicians seeing patients in a setting similar to ours (specialized diabetic foot unit with a high prevalence of osteomyelitis) can confidently diagnose diabetic foot osteomyelitis when either the probe-to-bone test or a plain X-ray, or especially both, are positive. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.
PIONEER VENUS 2 MULTI-PROBE PARACHUTE TESTS IN THE VAB SHOWS OPEN PARACHUTE
NASA Technical Reports Server (NTRS)
1975-01-01
A parachute system, designed to carry an instrument-laden probe down through the dense atmosphere of torrid, cloud-shrouded Venus, was tested in KSC's Vehicle Assembly Building. The tests are in preparation for a Pioneer multi-probe mission to Venus scheduled for launch from KSC in 1978. Full-scale (12-foot diameter) parachutes with simulated pressure vessels weighing up to 45 pounds were dropped from heights of up to 450 feet tot he floor of the VAB where the impact was cushioned by a honeycomb cardboard impact arrestor. The VAB offers an ideal, wind-free testing facility at no additional construction cost and was used for similar tests of the parachute system for the twin Viking spacecraft scheduled for launch toward Mars in August.
PIONEER VENUS 2 MULTI-PROBE PARACHUTE TESTS IN VAB WITH PARACHUTE HOISTED HIGH
NASA Technical Reports Server (NTRS)
1975-01-01
A parachute system, designed to carry an instrument-laden probe down through the dense atmosphere of torrid, cloud-shrouded Venus, was tested in KSC's Vehicle Assembly Building. The tests are in preparation for a Pioneer multi-probe mission to Venus scheduled for launch from KSC in 1978. Full-scale (12-foot diameter) parachutes with simulated pressure vessels weighing up to 45 pounds were dropped from heights of up to 450 feet tot he floor of the VAB where the impact was cushioned by a honeycomb cardboard impact arrestor. The VAB offers an ideal, wind-free testing facility at no additional construction cost and was used for similar tests of the parachute system for the twin Viking spacecraft scheduled for launch toward Mars in August.
PIONEER VENUS 2 MULTI-PROBE PARACHUTE TESTS IN VAB PRIOR TO ATTACHING PRESSURE VESSEL
NASA Technical Reports Server (NTRS)
1975-01-01
A parachute system, designed to carry an instrument-laden probe down through the dense atmosphere of torrid, cloud-shrouded Venus, was tested in KSC's Vehicle Assembly Building. The tests are in preparation for a Pioneer multi-probe mission to Venus scheduled for launch from KSC in 1978. Full-scale (12-foot diameter) parachutes with simulated pressure vessels weighing up to 45 pounds were dropped from heights of up to 450 feet tot he floor of the VAB where the impact was cushioned by a honeycomb cardboard impact arrestor. The VAB offers an ideal, wind-free testing facility at no additional construction cost and was used for similar tests of the parachute system for the twin Viking spacecraft scheduled for launch toward Mars in August.
PIONEER VENUS 2 MULTI-PROBE PARACHUTE TESTS IN THE VEHICLE ASSEMBLY BUILDING
NASA Technical Reports Server (NTRS)
1975-01-01
A parachute system, designed to carry an instrument-laden probe down through the dense atmosphere of torrid, cloud-shrouded Venus, was tested in KSC's Vehicle Assembly Building. The tests are in preparation for a Pioneer multi-probe mission to Venus scheduled for launch from KSC in 1978. Full-scale (12-foot diameter) parachutes with simulated pressure vessels weighing up to 45 pounds were dropped from heights of up to 450 feet tot he floor of the VAB where the impact was cushioned by a honeycomb cardboard impact arrestor. The VAB offers an ideal, wind-free testing facility at no additional construction cost and was used for similar tests of the parachute system for the twin Viking spacecraft scheduled for launch toward Mars in August.
Preston Probe Calibrations at High Reynolds Number
NASA Technical Reports Server (NTRS)
Smits, Alexander J.
1998-01-01
The overall goal of the research effort is to study the performance of two Preston probes designed by NASA Langley Research Center across an unprecedented range of Reynolds number (based on friction velocity and probe diameter), and perform an accurate calibration over the same Reynolds number range. Using the Superpipe facility in Princeton, two rounds of experiments were performed. In each round of experiments for each Reynolds number, the pressure gradient, static pressure from the Preston probes and the total pressure from the Preston probes were measured. In the first round, 3 Preston probes having outer diameters of 0.058 inches, 0.083 inches and 0.203 inches were tested over a large range of pipe Reynolds numbers. Two data reduction methods were employed: first, the static pressure measured on the Preston probe was used to calculate P (modified Preston probe configuration), and secondly, the static pressure measured at the reference pressure tap was used to calculate P (un-modified Preston probe configuration). For both methods, the static pressure was adjusted to correspond with the static pressure at the Preston probe tip using the pressure gradient. The measurements for Preston probes with diameters of 0.058 inches, and 0.083 inches respectively were performed in the test pipe before it was polished a second time. Therefore, the measurements at high pipe Reynolds numbers may have been affected by roughness. In the second round of experiments the 0.058 inches and 0.083 inches diameter, un-modified probes were tested after the pipe was polished and prepared to ensure that the surface was smooth. The average velocity was estimated by assuming that the connection between the centerline velocity and the average velocity was known, and by using a Pitot tube to measure the centerline velocity. A preliminary error estimate suggests that it is possible to introduce a 1% to 2% error in estimating the average velocity using this approach. The evidence on the errors attending the second data set is somewhat circumstantial, and the measurements have not been repeated using a better approach, it seems probable that the correlation given applies to un-modified Preston probes over the range 6.4 less than x* less than 11.3.
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Hill, Carrie S.
2013-01-01
Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are useful for performing measurements in electric space thrusters and various plasma accelerator applications where a time-varying magnetic field is present. Magnetic field probes have proven to be a mainstay in diagnosing plasma thrusters where changes occur rapidly with respect to time, providing the means to measure the magnetic fields produced by time-varying currents and even an indirect measure of the plasma current density through the application of Ampère's law. Examples of applications where this measurement technique has been employed include pulsed plasma thrusters and quasi-steady magnetoplasmadynamic thrusters. The Electric Propulsion Technical Committee (EPTC) of the American Institute of Aeronautics and Astronautics (AIAA) was asked to assemble a Committee on Standards (CoS) for Electric Propulsion Testing. The assembled CoS was tasked with developing Standards and Recommended Practices for various diagnostic techniques used in the evaluation of plasma thrusters. These include measurements that can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. This paper presents a summary of the standard, describing the preferred methods for fabrication, calibration, and usage of inductive magnetic field probes for use in diagnosing plasma thrusters. Inductive magnetic field probes (also called B-dot probes throughout this document) are commonly used in electric propulsion (EP) research and testing to measure unsteady magnetic fields produced by time-varying currents. The B-dot probe is relatively simple in construction, and requires minimal cost, making it a low-cost technique that is readily accessible to most researchers. While relatively simple, the design of a B-dot probe is not trivial and there are many opportunities for errors in probe construction, calibration, and usage, and in the post-processing of data that is produced by the probe. There are typically several ways in which each of these steps can be approached, and different applications may require more or less vigorous attention to various issues.
Retractable pin dual in-line package test clip
Bandzuch, Gregory S.; Kosslow, William J.
1996-01-01
This invention is a Dual In-Line Package (DIP) test clip for use when troubleshooting circuits containing DIP integrated circuits. This test clip is a significant improvement over existing DIP test clips in that it has retractable pins which will permit troubleshooting without risk of accidentally shorting adjacent pins together when moving probes to different pins on energized circuits or when the probe is accidentally bumped while taking measurements.
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact test is the... a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac impact... surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000 kg-cm2...
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact test is the... a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac impact... surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000 kg-cm2...
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact test is the... a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac impact... surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000 kg-cm2...
Thermal Protection System Development, Testing and Qualification
NASA Astrophysics Data System (ADS)
Venkatapathy, Ethiraj; Arnold, James; Laub, B.; Hartman, G. J.
The science community currently has interest in planetary entry probe missions to improve our understanding of the atmospheres of Saturn and Venus [1,2]. As in the case of the Galileo entry probe, such data are critical to the understanding of not only the individual planets but also to further knowledge regarding the formation of the solar system. It is believed that Saturn probes to depths corresponding to 10 bars will be sufficient [1] to provide the desired scientific data. The heating rates for the "shallow" Saturn probes and Venus are in the range of 2 - 5KW/cm2 . It is clear that new, mid-density Thermal Protection System (TPS) materials for such probes can be mission-enabling for mass efficiency [3] and also make the use of smaller vehicles possible from advancements in scientific instrumentation [4]. Past consideration of new Jovian multiprobe missions has been considered problematic without the Giant Planet Arcjet Facility that was used to qualify Carbon Phenolic for the Galileo Probe. This paper describes emerging TPS technology and the proposed use of an affordable, small 5 MW arc jet that can be used for TPS development in test gases appropriate for the aforementioned, new planetary probe applications. Emerging TPS technologies of interest include a mid-density, chopped molded carbon phenolic (CMCP) material around 0.8g/cc and a densified variant of phenolic impregnated carbon ablator (PICA) around 0.5g/cc. The small 5 MW arc jet facility, called the Development Arcjet Facility (DAF) and the methodology of testing TPS, both based on previous work, are discussed. Finally, the applications to Earth entry appropriate to speeds greater than lunar return (11km/s) are discussed as will facility-to-facility validation using air as a test gas. The use of other facilities for development, qualification and certification of TPS for Saturn and Venus is also discussed. [1] Atreya, S. K., et. al. Formation of Giant Planets and Their Atmospheres: Entry Probes for Saturn and Beyond; 5 th International Planetary Probe Workshop, June 25-29, Bordeaux, France. [2] Baines, K. H, et. al, Exploring Venus with Balloons: Science Objectives and Mission Architectures. 5 th International Planetary Probe Workshop, June 25-29 Bordeaux, France.
NASA Technical Reports Server (NTRS)
Davison, Craig R.; Landreville, Charles; Ratvasky, Thomas P.
2017-01-01
A new compact isokinetic probe to measure total water content in a wind tunnel environment has been developed. The probe has been previously tested under altitude conditions. This paper presents a comprehensive validation of the probe under a range of liquid water conditions at sea level in the NASA Glenn Icing Research Tunnel and with ice crystals at sea level at the NRC wind tunnel. The compact isokinetic probe is compared to tunnel calibrations and other probes.
Zhang, Xiaoying; Liu, Songhuai; Yang, Degang; Du, Liangjie; Wang, Ziyuan
2016-08-01
[Purpose] The purpose of this study was to examine the immediate effects of therapeutic keyboard music playing on the finger function of subjects' hands through measurements of the joint position error test, surface electromyography, probe reaction time, and writing time. [Subjects and Methods] Ten subjects were divided randomly into experimental and control groups. The experimental group used therapeutic keyboard music playing and the control group used grip training. All subjects were assessed and evaluated by the joint position error test, surface electromyography, probe reaction time, and writing time. [Results] After accomplishing therapeutic keyboard music playing and grip training, surface electromyography of the two groups showed no significant change, but joint position error test, probe reaction time, and writing time obviously improved. [Conclusion] These results suggest that therapeutic keyboard music playing is an effective and novel treatment for improving joint position error test scores, probe reaction time, and writing time, and it should be promoted widely in clinics.
Concealed semantic and episodic autobiographical memory electrified.
Ganis, Giorgio; Schendan, Haline E
2012-01-01
Electrophysiology-based concealed information tests (CIT) try to determine whether somebody possesses concealed information about a crime-related item (probe) by comparing event-related potentials (ERPs) between this item and comparison items (irrelevants). Although the broader field is sometimes referred to as "memory detection," little attention has been paid to the precise type of underlying memory involved. This study begins addressing this issue by examining the key distinction between semantic and episodic memory in the autobiographical domain within a CIT paradigm. This study also addresses the issue of whether multiple repetitions of the items over the course of the session habituate the brain responses. Participants were tested in a 3-stimulus CIT with semantic autobiographical probes (their own date of birth) and episodic autobiographical probes (a secret date learned just before the study). Results dissociated these two memory conditions on several ERP components. Semantic probes elicited a smaller frontal N2 than episodic probes, consistent with the idea that the frontal N2 decreases with greater pre-existing knowledge about the item. Likewise, semantic probes elicited a smaller central N400 than episodic probes. Semantic probes also elicited a larger P3b than episodic probes because of their richer meaning. In contrast, episodic probes elicited a larger late positive complex (LPC) than semantic probes, because of the recent episodic memory associated with them. All these ERPs showed a difference between probes and irrelevants in both memory conditions, except for the N400, which showed a difference only in the semantic condition. Finally, although repetition affected the ERPs, it did not reduce the difference between probes and irrelevants. These findings show that the type of memory associated with a probe has both theoretical and practical importance for CIT research.
Concealed semantic and episodic autobiographical memory electrified
Ganis, Giorgio; Schendan, Haline E.
2013-01-01
Electrophysiology-based concealed information tests (CIT) try to determine whether somebody possesses concealed information about a crime-related item (probe) by comparing event-related potentials (ERPs) between this item and comparison items (irrelevants). Although the broader field is sometimes referred to as “memory detection,” little attention has been paid to the precise type of underlying memory involved. This study begins addressing this issue by examining the key distinction between semantic and episodic memory in the autobiographical domain within a CIT paradigm. This study also addresses the issue of whether multiple repetitions of the items over the course of the session habituate the brain responses. Participants were tested in a 3-stimulus CIT with semantic autobiographical probes (their own date of birth) and episodic autobiographical probes (a secret date learned just before the study). Results dissociated these two memory conditions on several ERP components. Semantic probes elicited a smaller frontal N2 than episodic probes, consistent with the idea that the frontal N2 decreases with greater pre-existing knowledge about the item. Likewise, semantic probes elicited a smaller central N400 than episodic probes. Semantic probes also elicited a larger P3b than episodic probes because of their richer meaning. In contrast, episodic probes elicited a larger late positive complex (LPC) than semantic probes, because of the recent episodic memory associated with them. All these ERPs showed a difference between probes and irrelevants in both memory conditions, except for the N400, which showed a difference only in the semantic condition. Finally, although repetition affected the ERPs, it did not reduce the difference between probes and irrelevants. These findings show that the type of memory associated with a probe has both theoretical and practical importance for CIT research. PMID:23355816
'Incremental thermocouple probe' for testing insulation erosion on a rocket motor
NASA Technical Reports Server (NTRS)
Gould, Reginald J.
1993-01-01
An incremental thermocouple probe was developed to measure insulation erosion during a solid rocket motor firing. The probe's new and unique design is described along with its theory of operation. Data from an actual firing are reported which show that the probe's performance greatly exceeded predictions and present technology as a temperature measurement device and as an event gage.
How to Say No: Single- and Dual-Process Theories of Short-Term Recognition Tested on Negative Probes
ERIC Educational Resources Information Center
Oberauer, Klaus
2008-01-01
Three experiments with short-term recognition tasks are reported. In Experiments 1 and 2, participants decided whether a probe matched a list item specified by its spatial location. Items presented at study in a different location (intrusion probes) had to be rejected. Serial position curves of positive, new, and intrusion probes over the probed…
The Delivery of Water During Terrestrial Planet Formation
NASA Astrophysics Data System (ADS)
O'Brien, David P.; Izidoro, Andre; Jacobson, Seth A.; Raymond, Sean N.; Rubie, David C.
2018-02-01
The planetary building blocks that formed in the terrestrial planet region were likely very dry, yet water is comparatively abundant on Earth. Here we review the various mechanisms proposed for the origin of water on the terrestrial planets. Various in-situ mechanisms have been suggested, which allow for the incorporation of water into the local planetesimals in the terrestrial planet region or into the planets themselves from local sources, although all of those mechanisms have difficulties. Comets have also been proposed as a source, although there may be problems fitting isotopic constraints, and the delivery efficiency is very low, such that it may be difficult to deliver even a single Earth ocean of water this way. The most promising route for water delivery is the accretion of material from beyond the snow line, similar to carbonaceous chondrites, that is scattered into the terrestrial planet region as the planets are growing. Two main scenarios are discussed in detail. First is the classical scenario in which the giant planets begin roughly in their final locations and the disk of planetesimals and embryos in the terrestrial planet region extends all the way into the outer asteroid belt region. Second is the Grand Tack scenario, where early inward and outward migration of the giant planets implants material from beyond the snow line into the asteroid belt and terrestrial planet region, where it can be accreted by the growing planets. Sufficient water is delivered to the terrestrial planets in both scenarios. While the Grand Tack scenario provides a better fit to most constraints, namely the small mass of Mars, planets may form too fast in the nominal case discussed here. This discrepancy may be reduced as a wider range of initial conditions is explored. Finally, we discuss several more recent models that may have important implications for water delivery to the terrestrial planets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierens, Arnaud; Raymond, Sean N.; Nesvorny, David
Embedded in the gaseous protoplanetary disk, Jupiter and Saturn naturally become trapped in 3:2 resonance and migrate outward. This serves as the basis of the Grand Tack model. However, previous hydrodynamical simulations were restricted to isothermal disks, with moderate aspect ratio and viscosity. Here we simulate the orbital evolution of the gas giants in disks with viscous heating and radiative cooling. We find that Jupiter and Saturn migrate outward in 3:2 resonance in modest-mass (M {sub disk} ≈ M {sub MMSN}, where MMSN is the {sup m}inimum-mass solar nebula{sup )} disks with viscous stress parameter α between 10{sup –3} andmore » 10{sup –2}. In disks with relatively low-mass (M {sub disk} ≲ M {sub MMSN}), Jupiter and Saturn get captured in 2:1 resonance and can even migrate outward in low-viscosity disks (α ≤ 10{sup –4}). Such disks have a very small aspect ratio (h ∼ 0.02-0.03) that favors outward migration after capture in 2:1 resonance, as confirmed by isothermal runs which resulted in a similar outcome for h ∼ 0.02 and α ≤ 10{sup –4}. We also performed N-body runs of the outer solar system starting from the results of our hydrodynamical simulations and including 2-3 ice giants. After dispersal of the gaseous disk, a Nice model instability starting with Jupiter and Saturn in 2:1 resonance results in good solar systems analogs. We conclude that in a cold solar nebula, the 2:1 resonance between Jupiter and Saturn can lead to outward migration of the system, and this may represent an alternative scenario for the evolution of the solar system.« less
Simulation of upwind maneuvering of a sailing yacht
NASA Astrophysics Data System (ADS)
Harris, Daniel Hartrick
A time domain maneuvering simulation of an IACC class yacht suitable for the analysis of unsteady upwind sailing including tacking is presented. The simulation considers motions in six degrees of freedom. The hydrodynamic and aerodynamic loads are calculated primarily with unsteady potential theory supplemented by empirical viscous models. The hydrodynamic model includes the effects of incident waves. Control of the rudder is provided by a simple rate feedback autopilot which is augmented with open loop additions to mimic human steering. The hydrodynamic models are based on the superposition of force components. These components fall into two groups, those which the yacht will experience in calm water, and those due to incident waves. The calm water loads are further divided into zero Froude number, or "double body" maneuvering loads, hydrostatic loads, gravitational loads, free surface radiation loads, and viscous/residual loads. The maneuvering loads are calculated with an unsteady panel code which treats the instantaneous geometry of the yacht below the undisturbed free surface. The free surface radiation loads are calculated via convolution of impulse response functions derived from seakeeping strip theory. The viscous/residual loads are based upon empirical estimates. The aerodynamic model consists primarily of a database of steady state sail coefficients. These coefficients treat the individual contributions to the total sail force of a number of chordwise strips on both the main and jib. Dynamic effects are modeled by using the instantaneous incident wind velocity and direction as the independent variables for the sail load contribution of each strip. The sail coefficient database was calculated numerically with potential methods and simple empirical viscous corrections. Additional aerodynamic load calculations are made to determine the parasitic contributions of the rig and hull. Validation studies compare the steady sailing hydro and aerodynamic loads, seaway induced motions, added resistance in waves, and tacking performance with trials data and other sources. Reasonable agreement is found in all cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumura, Soko; Brasser, Ramon; Ida, Shigeru, E-mail: s.matsumura@dundee.ac.uk
2016-02-10
Recent observations started revealing the compositions of protostellar disks and planets beyond the solar system. In this paper, we explore how the compositions of terrestrial planets are affected by the dynamical evolution of giant planets. We estimate the initial compositions of the building blocks of these rocky planets by using a simple condensation model, and numerically study the compositions of planets formed in a few different formation models of the solar system. We find that the abundances of refractory and moderately volatile elements are nearly independent of formation models, and that all the models could reproduce the abundances of thesemore » elements of the Earth. The abundances of atmophile elements, on the other hand, depend on the scattering rate of icy planetesimals into the inner disk, as well as the mixing rate of the inner planetesimal disk. For the classical formation model, neither of these mechanisms are efficient and the accretion of atmophile elements during the final assembly of terrestrial planets appears to be difficult. For the Grand Tack model, both of these mechanisms are efficient, which leads to a relatively uniform accretion of atmophile elements in the inner disk. It is also possible to have a “hybrid” scenario where the mixing is not very efficient but the scattering is efficient. The abundances of atmophile elements in this case increase with orbital radii. Such a scenario may occur in some of the extrasolar planetary systems, which are not accompanied by giant planets or those without strong perturbations from giants. We also confirm that the Grand Tack scenario leads to the distribution of asteroid analogues where rocky planetesimals tend to exist interior to icy ones, and show that their overall compositions are consistent with S-type and C-type chondrites, respectively.« less
Evaluation of a pulse oximeter sensor tester.
Dugani, Shuba; Hodzovic, Iljaz; Sindhakar, Seema; Nadra, Aida; Dunstan, Clare; Wilkes, Anthony Richard; Mecklenburgh, John
2011-06-01
The Lightman is intended to test the optical and electrical properties of a pulse oximeter probe including the wavelength of the light emitting diode by means of a micro spectrometer. The aim of this study was to evaluate the ability of the Lightman to detect faulty pulse oximeter finger probes by testing the accuracy of the wavelength of the light emitting diode in isolation from the monitor. The pulse oximeter measurements of arterial oxygen saturation from the "accurate" and "inaccurate" probes, as identified by the Lightman, were compared with arterial saturation determined by a co-oximeter. Data was analysed from 63 sets of measurements. In addition, we conducted a national survey to determine the testing procedures used by the Biomedical Engineering departments to evaluate the accuracy of pulse oximeter devices. The bias [95% limits of agreement] for accurate, over-reading and under-reading probes were 0.17% [3.6 to -3.3], 1.44% [5.4 to -2.5] and -1.6% [2.6 to -5.8] respectively. The response rate to the national survey was 75% (142/189); a pulse oximeter tester was used by 93/142 (65%) trusts. Our findings suggest that the Lightman can detect faulty probes and predict reasonably accurately the direction of the probe's error. The Lightman may be considered as a useful tool to assess the accuracy of pulse oximeters. The national survey highlighted a wide variation in the testing procedure utilised to evaluate the accuracy of pulse oximeters. Introduction of guidelines regarding the testing procedure would promote a uniform practice.
Hollow fiber-optic Raman probes for small experimental animals
NASA Astrophysics Data System (ADS)
Katagiri, Takashi; Hattori, Yusuke; Suzuki, Toshiaki; Matsuura, Yuji; Sato, Hidetoshi
2007-02-01
Two types of hollow fiber-optic probes are developed to measure the in vivo Raman spectra of small animals. One is the minimized probe which is end-sealed with the micro-ball lens. The measured spectra reflect the information of the sample's sub-surface. This probe is used for the measurement of the esophagus and the stomach via an endoscope. The other probe is a confocal Raman probe which consists of a single fiber and a lens system. It is integrated into the handheld microscope. A simple and small multimodal probe is realized because the hollow optical fiber requires no optical filters. The performance of each probe is examined and the effectiveness of these probes for in vivo Raman spectroscopy is shown by animal tests.
Improving the viability and versatility of the E × B probe with an active cooling system.
Liu, Lihui; Cai, Guobiao; You, Fengyi; Ren, Xiang; Zheng, Hongru; He, Bijiao
2018-04-01
A thermostatic E × B probe is designed to protect the probe body from the thermal effect of the plasma plume that has a significant influence on the resolution of the probe for high-power electric thrusters. An active cooling system, which consists of a cooling panel and carbon fiber felts combined with a recycling system of liquid coolants or an open-type system of gas coolants, is employed to realize the protection of the probe. The threshold for the design parameters for the active cooling system is estimated by deriving the energy transfer of the plasma plume-probe body interaction and the energy taken away by the coolants, and the design details are explained. The diagnostics of the LIPS-300 ion thruster with a power of 3 kW and a screen-grid voltage of 1450 V was implemented by the designed thermostatic E × B probe. The measured spectra illustrate that the thermostatic E × B probe can distinguish the fractions of Xe + ions and Xe 2+ ions without areas of overlap. In addition, the temperature of the probe body was less than 306 K in the beam region of the plasma plume during the 200-min-long continuous test. A thermostatic E × B probe is useful for enhancing the viability and versatility of equipment and for reducing uneconomical and complex test procedures.
Improving the viability and versatility of the E × B probe with an active cooling system
NASA Astrophysics Data System (ADS)
Liu, Lihui; Cai, Guobiao; You, Fengyi; Ren, Xiang; Zheng, Hongru; He, Bijiao
2018-04-01
A thermostatic E × B probe is designed to protect the probe body from the thermal effect of the plasma plume that has a significant influence on the resolution of the probe for high-power electric thrusters. An active cooling system, which consists of a cooling panel and carbon fiber felts combined with a recycling system of liquid coolants or an open-type system of gas coolants, is employed to realize the protection of the probe. The threshold for the design parameters for the active cooling system is estimated by deriving the energy transfer of the plasma plume-probe body interaction and the energy taken away by the coolants, and the design details are explained. The diagnostics of the LIPS-300 ion thruster with a power of 3 kW and a screen-grid voltage of 1450 V was implemented by the designed thermostatic E × B probe. The measured spectra illustrate that the thermostatic E × B probe can distinguish the fractions of Xe+ ions and Xe2+ ions without areas of overlap. In addition, the temperature of the probe body was less than 306 K in the beam region of the plasma plume during the 200-min-long continuous test. A thermostatic E × B probe is useful for enhancing the viability and versatility of equipment and for reducing uneconomical and complex test procedures.
2014-07-01
THE SOLAR PROBE PLUS CUP INSTRUMENT WILL BE PART OF THE SOLAR PROBE PLUS MISSION TO STUDY THE SUN. THE CUP WILL FLY ON THE SPACECRAFT ON THE OUTSIDE OF THE SHIELD AND WILL "CATCH" CHARGED PARTICLES FROM THE SUN AND ANALYZE THEM. A TEAM FROM THE HARVARD SMITHSONIAN ASTROPHYSICS OBSERVATORY IS BUILDING THIS INSTRUMENT AND TESTED AN ENGINEERING MODEL OF THE CUP IN AN ENVIRONMENTAL TEST FACILITY AT NASA'S MARSHALL SPACE FLIGHT CENTER.INSIDE THE VACUUM CHAMBER, THE PROBE WAS EXPOSED TO AN ENVIRONMENTAL CONDITIONS SIMILAR TO THOSE FOUND IN SPACE
Long working distance interference microscope
Sinclair, Michael B.; DeBoer, Maarten P.; Smith, Norman F.
2004-04-13
Disclosed is a long working distance interference microscope suitable for three-dimensional imaging and metrology of MEMS devices and test structures on a standard microelectronics probe station. The long working distance of 10-30 mm allows standard probes or probe cards to be used. This enables nanometer-scale 3-D height profiles of MEMS test structures to be acquired across an entire wafer. A well-matched pair of reference/sample objectives is not required, significantly reducing the cost of this microscope, as compared to a Linnik microinterferometer.
Mirza, M S; Rademaker, J L; Janse, J D; Akkermans, A D
1993-11-01
In this article we report on the polymerase chain reaction amplification of a partial 16S rRNA gene from the plant pathogenic bacterium Clavibacter michiganensis subsp. sepedonicus. A partial sequence (about 400 base pairs) of the gene was determined that covered two variable regions important for oligonucleotide probe development. A specific 24mer oligonucleotide probe targeted against the V6 region of 16S rRNA was designed. Specificity of the probe was determined using dot blot hybridization. Under stringent conditions (60 degrees C), the probe hybridized with all 16 Cl. michiganensis subsp. sepedonicus strains tested. Hybridization did not occur with 32 plant pathogenic and saprophytic bacteria used as controls under the same conditions. Under less stringent conditions (55 degrees C) the related Clavibacter michiganensis subsp. insidiosus, Clavibacter michiganensis subsp. nebraskensis, and Clavibacter michiganensis subsp. tesselarius also showed hybridization. At even lower stringency (40 degrees C), all Cl. michiganensis subspecies tested including Clavibacter michiganensis subsp. michiganensis showed hybridization signal, suggesting that under these conditions the probe may be used as a species-specific probe for Cl. michiganensis.
Aspheric surface measurement using capacitive probes
NASA Astrophysics Data System (ADS)
Tao, Xin; Yuan, Daocheng; Li, Shaobo
2017-02-01
With the application of aspheres in optical fields, high precision and high efficiency aspheric surface metrology becomes a hot research topic. We describe a novel method of non-contact measurement of aspheric surface with capacitive probe. Taking an eccentric spherical surface as the object of study, the averaging effect of capacitive probe measurement and the influence of tilting the capacitive probe on the measurement results are investigated. By comparing measurement results from simultaneous measurement of the capacitive probe and contact probe of roundness instrument, this paper indicates the feasibility of using capacitive probes to test aspheric surface and proposes the compensation method of measurement error caused by averaging effect and the tilting of the capacitive probe.
Use of soil moisture probes to estimate ground water recharge at an oil spill site
Delin, G.N.; Herkelrath, W.N.
2005-01-01
Soil moisture data collected using an automated data logging system were used to estimate ground water recharge at a crude oil spill research site near Bemidji, Minnesota. Three different soil moisture probes were tested in the laboratory as well as the field conditions of limited power supply and extreme weather typical of northern Minnesota: a self-contained reflectometer probe, and two time domain reflectometry (TDR) probes, 30 and 50 cm long. Recharge was estimated using an unsaturated zone water balance method. Recharge estimates for 1999 using the laboratory calibrations were 13 to 30 percent greater than estimates based on the factory calibrations. Recharge indicated by the self-contained probes was 170 percent to 210 percent greater than the estimates for the TDR probes regardless of calibration method. Results indicate that the anomalously large recharge estimates for the self-contained probes are not the result of inaccurate measurements of volumetric moisture content, but result from the presence of crude oil, or bore-hole leakage. Of the probes tested, the 50 cm long TDR probe yielded recharge estimates that compared most favorably to estimates based on a method utilizing water table fluctuations. Recharge rates for this probe represented 24 to 27 percent of 1999 precipitation. Recharge based on the 30 cm long horizontal TDR probes was 29 to 37 percent of 1999 precipitation. By comparison, recharge based on the water table fluctuation method represented about 29 percent of precipitation. (JAWRA) (Copyright ?? 2005).
Factors Influencing Pitot Probe Centerline Displacement in a Turbulent Supersonic Boundary Layer
NASA Technical Reports Server (NTRS)
Grosser, Wendy I.
1997-01-01
When a total pressure probe is used for measuring flows with transverse total pressure gradients, a displacement of the effective center of the probe is observed (designated Delta). While this phenomenon is well documented in incompressible flow and supersonic laminar flow, there is insufficient information concerning supersonic turbulent flow. In this study, three NASA Lewis Research Center Supersonic Wind Tunnels (SWT's) were used to investigate pitot probe centerline displacement in supersonic turbulent boundary layers. The relationship between test conditions and pitot probe centerline displacement error was to be determined. For this investigation, ten circular probes with diameter-to-boundary layer ratios (D/delta) ranging from 0.015 to 0.256 were tested in the 10 ft x 10 ft SWT, the 15 cm x 15 cm SWT, and the 1 ft x 1 ft SWT. Reynolds numbers of 4.27 x 10(exp 6)/m, 6.00 x 10(exp 6)/in, 10.33 x 10(exp 6)/in, and 16.9 x 10(exp 6)/m were tested at nominal Mach numbers of 2.0 and 2.5. Boundary layer thicknesses for the three tunnels were approximately 200 mm, 13 mm, and 30 mm, respectively. Initial results indicate that boundary layer thickness, delta, and probe diameter, D/delta play a minimal role in pitot probe centerline offset error, Delta/D. It appears that the Mach gradient, dM/dy, is an important factor, though the exact relationship has not yet been determined. More data is needed to fill the map before a conclusion can be drawn with any certainty. This research provides valuable supersonic, turbulent boundary layer data from three supersonic wind tunnels with three very different boundary layers. It will prove a valuable stepping stone for future research into the factors influencing pitot probe centerline offset error.
The development of a universal diagnostic probe system for Tokamak fusion test reactor
NASA Technical Reports Server (NTRS)
Mastronardi, R.; Cabral, R.; Manos, D.
1982-01-01
The Tokamak Fusion Test Reactor (TFTR), the largest such facility in the U.S., is discussed with respect to instrumentation in general and mechanisms in particular. The design philosophy and detailed implementation of a universal probe mechanism for TFTR is discussed.
Stender, Henrik; Kurtzman, Cletus; Hyldig-Nielsen, Jens J.; Sørensen, Ditte; Broomer, Adam; Oliveira, Kenneth; Perry-O'Keefe, Heather; Sage, Andrew; Young, Barbara; Coull, James
2001-01-01
A new fluorescence in situ hybridization method using peptide nucleic acid (PNA) probes for identification of Brettanomyces is described. The test is based on fluorescein-labeled PNA probes targeting a species-specific sequence of the rRNA of Dekkera bruxellensis. The PNA probes were applied to smears of colonies, and results were interpreted by fluorescence microscopy. The results obtained from testing 127 different yeast strains, including 78 Brettanomyces isolates from wine, show that the spoilage organism Brettanomyces belongs to the species D. bruxellensis and that the new method is able to identify Brettanomyces (D. bruxellensis) with 100% sensitivity and 100% specificity. PMID:11157265
Modular 3D-Printed Soil Gas Probes
NASA Astrophysics Data System (ADS)
Good, S. P.; Selker, J. S.; Al-Qqaili, F.; Lopez, M.; Kahel, L.
2016-12-01
ABSTRACT: Extraction of soil gas is required for a variety of applications in earth sciences and environmental engineering. However, commercially available probes can be costly and are typically limited to a single depth. Here, we present the open-source design and lab testing of a soil gas probe with modular capabilities that allow for the vertical stacking of gas extraction points at different depths in the soil column. The probe modules consist of a 3D printed spacer unit and hydrophobic gas permeable membrane made of high density Polyethylene with pore sizes 20-40 microns. Each of the modular spacer units contain both a gas extraction line and gas input line for the dilution of soil gases if needed. These 2-inch diameter probes can be installed in the field quickly with a hand auger and returned to at any frequency to extract soil gas from desired soil depths. The probes are tested through extraction of soil pore water vapors with distinct stable isotope ratios.
Pico Reentry Probes: Affordable Options for Reentry Measurements and Testing
NASA Technical Reports Server (NTRS)
Ailor, William H.; Kapoor, Vinod B.; Allen, Gay A., Jr.; Venkatapathy, Ethiraj; Arnold, James O.; Rasky, Daniel J.
2005-01-01
It is generally very costly to perform in-space and atmospheric entry experiments. This paper presents a new platform - the Pico Reentry Probe (PREP) - that we believe will make targeted flight-tests and planetary atmospheric probe science missions considerably more affordable. Small, lightweight, self-contained, it is designed as a "launch and forget" system, suitable for experiments that require no ongoing communication with the ground. It contains a data recorder, battery, transmitter, and user-customized instrumentation. Data recorded during reentry or space operations is returned at end-of-mission via transmission to Iridium satellites (in the case of earth-based operations) or a similar orbiting communication system for planetary missions. This paper discusses possible applications of this concept for Earth and Martian atmospheric entry science. Two well-known heritage aerodynamic shapes are considered as candidates for PREP: the shape developed for the Planetary Atmospheric Experiment Test (PAET) and that for the Deep Space II Mars Probe.
NASA Astrophysics Data System (ADS)
Wier, Timothy P.; Moser, Cameron S.; Grant, Jonathan F.; Riley, Scott C.; Robbins-Wamsley, Stephanie H.; First, Matthew R.; Drake, Lisa A.
2017-10-01
Both L-shaped ("L") and straight ("Straight") sample probes have been used to collect water samples from a main ballast line in land-based or shipboard verification testing of ballast water management systems (BWMS). A series of experiments was conducted to quantify and compare the sampling efficiencies of L and Straight sample probes. The findings from this research-that both L and Straight probes sample organisms with similar efficiencies-permit increased flexibility for positioning sample probes aboard ships.
Numerical modeling of probe velocity effects for electromagnetic NDE methods
NASA Astrophysics Data System (ADS)
Shin, Y. K.; Lord, W.
The present discussion of magnetic flux (MLF) leakage inspection introduces the behavior of motion-induced currents. The results obtained indicate that velocity effects exist at even low probe speeds for magnetic materials, compelling the inclusion of velocity effects in MLF testing of oil pipelines, where the excitation level and pig speed are much higher than those used in the present work. Probe velocity effect studies should influence probe design, defining suitable probe speed limits and establishing training guidelines for defect-characterization schemes.
Johannsen, Annsofi; Tellefsen, Monica; Wikesjö, Ulf; Johannsen, Gunnar
2009-09-01
The aim of the present study was to evaluate the adjunctive effect of the local application of a hyaluronan gel to scaling and root planing in the treatment of chronic periodontitis. Twelve patients with chronic periodontitis were recruited to participate in a study with a split-mouth design and provided informed consent. Plaque formation and bleeding on probing were evaluated pretreatment (baseline) and at 1, 4, and 12 weeks post-treatment. Probing depths and attachment levels were evaluated at baseline and at 12 weeks. The patients received full-mouth scaling and root planing. A hyaluronan gel was administered subgingivally in the test sites at baseline and after 1 week. Significant differences between test and control were evaluated using the paired t test, repeated-measures analysis of variance (Wilks lambda), and a non-parametric Wilcoxon signed-rank test. A significant reduction in bleeding on probing scores and probing depths was observed in both groups at 12 weeks (P <0.05). Significantly lower bleeding on probing scores were observed in the hyaluronan group compared to control at 12 weeks (P <0.05). Mean probing depth reductions between baseline and 12 weeks were 1.0 +/- 0.3 mm and 0.8 +/- 0.2 mm for the hyaluronan and control groups, respectively. The difference between the groups was statistically significant (P <0.05). The local application of hyaluronan gel in conjunction with scaling and root planing may have a beneficial effect on periodontal health in patients with chronic periodontitis.
Kakar, Ashish; Kakar, Kanupriya
2013-05-01
To compare relief from dentin hypersensitivity (DH) after use of dentifrices formulated with potassium nitrate or fluoride. For the study, DH evaluations were conducted with the Jay Sensitivity Sensor Probe (Jay Probe), a novel tactile hypersensitivity instrument, in conjunction with three other DH methods, i.e. Yeaple probe (tactile), air blast, and the Visual Analog Scale (VAS). Adults (n = 100) who presented two teeth with DH and met study criteria were enrolled for this double-blind, randomized, parallel, controlled clinical trial conducted in an outpatient setting. DH evaluations at baseline were conducted by the tactile, air blast, and VAS methods. Subjects were randomly assigned a dentifrice formulated with 5% potassium nitrate and 1,000 ppm fluoride (as sodium monofluorophosphate) (Colgate Sensitive toothpaste; Test) or a commercially available fluoride dentifrice with 1,000 ppm fluoride as sodium monofluorophosphate (Colgate Cibaca toothpaste; Negative control). Subjects were recalled for DH evaluations after 4 and 8 weeks of product use. 85 subjects completed the entire study with evaluable results. Both treatments resulted in significant reductions in DH from baseline to all recall visits. In comparison to the Negative control, subjects in the Test group demonstrated significantly greater reductions for all DH evaluations at both 4 and 8 weeks (P < 0.05). Average tactile DH scores at week 8 for the Test and Negative control groups were 36.25 and 15.24 with the Yeaple probe and 35 and 12.43 with the Jay probe. Correspondingly, subjects in the Test group demonstrated significantly greater reductions in air blast and VAS responses for DH than those in the Negative control group (P < 0.05).
Fluorescent carbon nanoparticle-based lateral flow biosensor for ultrasensitive detection of DNA.
Takalkar, Sunitha; Baryeh, Kwaku; Liu, Guodong
2017-12-15
We report a fluorescent carbon nanoparticle (FCN)-based lateral flow biosensor for ultrasensitive detection of DNA. Fluorescent carbon nanoparticle with a diameter of around 15nm was used as a tag to label a detection DNA probe, which was complementary with the part of target DNA. A capture DNA probe was immobilized on the test zone of the lateral flow biosensor. Sandwich-type hybridization reactions among the FCN-labeled DNA probe, target DNA and capture DNA probe were performed on the lateral flow biosensor. In the presence of target DNA, FCNs were captured on the test zone of the biosensor and the fluorescent intensity of the captured FCNs was measured with a portable fluorescent reader. After systematic optimizations of experimental parameters (the components of running buffers, the concentration of detection DNA probe used in the preparation of FCN-DNA conjugates, the amount of FCN-DNA dispensed on the conjugate pad and the dispensing cycles of the capture DNA probes on the test-zone), the biosensor could detect a minimum concentration of 0.4 fM DNA. This study provides a rapid and low-cost approach for DNA detection with high sensitivity, showing great promise for clinical application and biomedical diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Brain Implants for Prediction and Mitigation of Epileptic Seizures - Final CRADA Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gopalsami, Nachappa
2016-09-29
This is a CRADA final report on C0100901 between Argonne National Laboratory and Flint Hills Scientific, LLC of Lawrence, Kansas. Two brain implantable probes, a surface acoustic wave probe and a miniature cooling probe, were designed, built, and tested with excellent results.
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... a minimum mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact... and it has a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac... impact surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000...
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... a minimum mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact... and it has a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac... impact surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000...
Open-target sparse sensing of biological agents using DNA microarray
2011-01-01
Background Current biosensors are designed to target and react to specific nucleic acid sequences or structural epitopes. These 'target-specific' platforms require creation of new physical capture reagents when new organisms are targeted. An 'open-target' approach to DNA microarray biosensing is proposed and substantiated using laboratory generated data. The microarray consisted of 12,900 25 bp oligonucleotide capture probes derived from a statistical model trained on randomly selected genomic segments of pathogenic prokaryotic organisms. Open-target detection of organisms was accomplished using a reference library of hybridization patterns for three test organisms whose DNA sequences were not included in the design of the microarray probes. Results A multivariate mathematical model based on the partial least squares regression (PLSR) was developed to detect the presence of three test organisms in mixed samples. When all 12,900 probes were used, the model correctly detected the signature of three test organisms in all mixed samples (mean(R2)) = 0.76, CI = 0.95), with a 6% false positive rate. A sampling algorithm was then developed to sparsely sample the probe space for a minimal number of probes required to capture the hybridization imprints of the test organisms. The PLSR detection model was capable of correctly identifying the presence of the three test organisms in all mixed samples using only 47 probes (mean(R2)) = 0.77, CI = 0.95) with nearly 100% specificity. Conclusions We conceived an 'open-target' approach to biosensing, and hypothesized that a relatively small, non-specifically designed, DNA microarray is capable of identifying the presence of multiple organisms in mixed samples. Coupled with a mathematical model applied to laboratory generated data, and sparse sampling of capture probes, the prototype microarray platform was able to capture the signature of each organism in all mixed samples with high sensitivity and specificity. It was demonstrated that this new approach to biosensing closely follows the principles of sparse sensing. PMID:21801424
NASA Technical Reports Server (NTRS)
Lih, Shyh-Shiuh (Inventor); Takano, Nobuyuki (Inventor); Lee, Hyeong Jae (Inventor); Bao, Xiaoqi (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Sherrit, Stewart (Inventor); Ostlund, Patrick N. (Inventor)
2017-01-01
A high temperature ultrasonic probe and a mounting fixture for attaching and aligning the probe to a steam pipe using blind alignment. The high temperature ultrasonic probe includes a piezoelectric transducer having a high temperature. The probe provides both transmitting and receiving functionality. The mounting fixture allows the high temperature ultrasonic probe to be accurately aligned to the bottom external surface of the steam pipe so that the presence of liquid water in the steam pipe can be monitored. The mounting fixture with a mounted high temperature ultrasonic probe are used to conduct health monitoring of steam pipes and to track the height of condensed water through the wall in real-time.
Assessment of energy demand in Laser sailing: influences of exercise duration and performance level.
Castagna, O; Brisswalter, J
2007-01-01
In this study we analyzed the influence of both exercise duration and skill level on energy demand in Laser sailing. Twenty-three subjects volunteered for this study. The population is divided into two groups according to their skill level: 13 high (HS) and 10 low (LS). Every subject performed a 30 min upwind sailing test, with a tacking every 2 min. Heart rate (HR), gas exchange and respiratory parameters were analyzed throughout the trial, and measured blood lactate concentration ([La(bl)] at rest and immediately after the exercise completion. Three, 4 min intervals were selected for analysis: 6-10 min (T10), 16-20 min (T20) and 26-30 min (T30). In contrast to previous studies, we found significantly progressive aerobic energy metabolism with sailing duration in the HS group (T10 = 45%; T20 = 61%; T30 = 68% VO2max, P < 0.05), whereas this demand remained stable, and significantly lower in LS group (T10 = 45%; T20 = 52%; T30 = 51% VO2max, P < 0.05). This study shows that aerobic demand is significantly more important in LS than in HS subjects after 30 min regatta, and could be an important factor in Laser regatta performance. We need further studies to confirm and explain this difference.
Films, Preimpregnated Tapes and Composites Made from Polyimide "Salt-Like" Solutions
NASA Technical Reports Server (NTRS)
Cano, Roberto J. (Inventor); Weiser, Erik S. (Inventor); St.Clair, Terry L. (Inventor); Echigo, Yoshiaki (Inventor); Kaneshiro, Hisayasu (Inventor)
2001-01-01
High quality films, preimpregnated tape (prepegs), and composites have been fabricated from polyimide precursor 'saltlike' solutions. These salt-like solutions have a low viscosity (5,000 to 10,000 cp) and a high solids content (50-65% by weight) and can be coated onto reinforcing fiber to produce prepegs with excellent tack and drape at 12-15% residual solvent (approximately 4-6% water from thermal imidization reaction). The processing of these types of prepegs significantly overcomes solvent removal problems and allows excellent fiber wet out. In addition, the physical characteristics of the polyimide precursor salt-like solutions permits processing into high-performance materials through the use of standard prepregging and composite fabrication equipment. The resultant composites are of high quality.
Apparatus to collect, classify, concentrate, and characterize gas-borne particles
Rader, Daniel J.; Torczynski, John R.; Wally, Karl; Brockmann, John E.
2003-12-16
An aerosol lab-on-a-chip (ALOC) integrates one or more of a variety of particle collection, classification, concentration (enrichment), an characterization processes onto a single substrate or layered stack of such substrates. By mounting a UV laser diode laser light source on the substrate, or substrates tack, so that it is located down-stream of the sample inlet port and at right angle the sample particle stream, the UV light source can illuminate individual particles in the stream to induce a fluorescence response in those particles having a fluorescent signature such as biological particles, some of said particles. An illuminated particle having a fluorescent signal above a threshold signal would trigger a sorter module that would separate that particle from the particle stream.
Therapeutic aspects of Puerto Rican cult practices.
Koss, J D
1975-05-01
This paper seeks to explore the phenomenon of possession trance in the ritual context from still another tack, complementary to the studies cited above, by analyzing it as an active and perhaps necessary component in the development of significant personal relationships basic to the organization and goals of some religous cults.-1 This view has been suggested by data gathered in study of social process in Puerto Rican Spiritist cults-2 which examined the relationship between patterns of cult social organization and the cult execution of a culturally patterned psychotherapeutic process for committed adherents whose emotional problems are diagnosed by cult headers as manifestations of developing "faculties" for communication with the spirit world-3 (see Koss; Rogler and Hollingshead, 1965, pp. 244-254; Seda Bonilla, 1964).
Visual and acoustic communication in non-human animals: a comparison.
Rosenthal, G G; Ryan, M J
2000-09-01
The visual and auditory systems are two major sensory modalities employed in communication. Although communication in these two sensory modalities can serve analogous functions and evolve in response to similar selection forces, the two systems also operate under different constraints imposed by the environment and the degree to which these sensory modalities are recruited for non-communication functions. Also, the research traditions in each tend to differ, with studies of mechanisms of acoustic communication tending to take a more reductionist tack often concentrating on single signal parameters, and studies of visual communication tending to be more concerned with multivariate signal arrays in natural environments and higher level processing of such signals. Each research tradition would benefit by being more expansive in its approach.
SARS: Safeguards Accounting and Reporting Software
NASA Astrophysics Data System (ADS)
Mohammedi, B.; Saadi, S.; Ait-Mohamed, S.
In order to satisfy the requirements of the SSAC (State System for Accounting and Control of nuclear materials), for recording and reporting objectives; this computer program comes to bridge the gape between nuclear facilities operators and national inspection verifying records and delivering reports. The SARS maintains and generates at-facility safeguards accounting records and generates International Atomic Energy Agency (IAEA) safeguards reports based on accounting data input by the user at any nuclear facility. A database structure is built and BORLAND DELPHI programming language has been used. The software is designed to be user-friendly, to make extensive and flexible management of menus and graphs. SARS functions include basic physical inventory tacking, transaction histories and reporting. Access controls are made by different passwords.
A simplified open gastrostomy under local anesthesia.
Zickler, R W; Barbagiovanni, J T; Swan, K G
2001-08-01
Revision of the standard gastrostomy is often necessary in patients with neuromuscular disorders. These patients pose many anesthetic risks that frequently preclude the use of general anesthesia, intravenous sedation, or endoscopy. Modification of the Stamm gastrostomy enables it to be performed comfortably and readily under local anesthesia. The modification proposed passes the gastrostomy tube through the omentum en route to the abdominal wall. This ensures a seal to the surgical site, eliminates the need for tacking sutures, and allows for a smaller midline incision. These factors greatly reduce the discomfort of the procedure allowing it to be easily accomplished under local anesthesia. This technique of open gastrostomy under local anesthesia has been used in more than 35 patients over the past 10 years with no documented leaks.
High Temperatures Health Monitoring of the Condensed Water Height in Steam Pipe Systems
NASA Technical Reports Server (NTRS)
Lih, Shyh-Shiuh; Bar-Cohen, Yoseph; Lee, Hyeong Jae; Badescu, Mircea; Bao, Xiaoqi; Sherrit, Stewart; Takano, Nobuyuki; Ostlund, Patrick; Blosiu, Julian
2013-01-01
Ultrasonic probes were designed, fabricated and tested for high temperature health monitoring system. The goal of this work was to develop the health monitoring system that can determine the height level of the condensed water through the pipe wall at high temperature up to 250 deg while accounting for the effects of surface perturbation. Among different ultrasonic probe designs, 2.25 MHz probes with air backed configuration provide satisfactory results in terms of sensitivity, receiving reflections from the target through the pipe wall. A series of tests were performed using the air-backed probes under irregular conditions, such as surface perturbation and surface disturbance at elevated temperature, to qualify the developed ultrasonic system. The results demonstrate that the fabricated air-backed probes combined with advanced signal processing techniques offer the capability of health monitoring of steam pipe under various operating conditions.
NASA Astrophysics Data System (ADS)
Yao, Yanbo; Duan, Xiaoshuang; Luo, Jiangjiang; Liu, Tao
2017-11-01
The use of the van der Pauw (VDP) method for characterizing and evaluating the piezoresistive behavior of carbon nanomaterial enabled piezoresistive sensors have not been systematically studied. By using single-wall carbon nanotube (SWCNT) thin films as a model system, herein we report a coupled electrical-mechanical experimental study in conjunction with a multiphysics finite element simulation as well as an analytic analysis to compare the two-probe and VDP testing configuration in evaluating the piezoresistive behavior of carbon nanomaterial enabled piezoresistive sensors. The key features regarding the sample aspect ratio dependent piezoresistive sensitivity or gauge factor were identified for the VDP testing configuration. It was found that the VDP test configuration offers consistently higher piezoresistive sensitivity than the two-probe testing method.
Jeangkhwoa, Pattraporn; Bandhaya, Achirapa; Umpunjun, Puangpaka; Chuenboonngarm, Ngarmnij; Panvisavas, Nathinee
2017-03-01
This study reports a successful application of fluorescence in situ hybridization (FISH) technique in the identification of Cannabis sativa L. cells recovered from fresh and dried powdered plant materials. Two biotin-16-dUTP-labeled FISH probes were designed from the Cannabis-specific tetrahydrocannabinolic acid synthase (THCAS) gene and the ITS region of the 45S rRNA gene. Specificity of probe-target hybridization was tested against the target and 4 non-target plant species, i.e., Humulus lupulus, Mitragyna speciosa, Papaver sp., and Nicotiana tabacum. The 1-kb THCA synthase hybridization probe gave Cannabis-specific hybridization signals, unlike the 700-bp Cannabis-ITS hybridization probe. Probe-target hybridization was also confirmed against 20 individual Cannabis plant samples. The 1-kb THCA synthase and 700-bp Cannabis-ITS hybridization probes clearly showed 2 hybridization signals per cell with reproducibility. The 1-kb THCA synthase probe did not give any FISH signal when tested against H. lupulus, its closely related member of the Canabaceae family. It was also showed that 1-kb THCA synthase FISH probe can be applied to identify small amount of dried powdered Cannabis material with an addition of rehydration step prior to the experimental process. This study provided an alternative identification method for Cannabis trace. Copyright © 2016. Published by Elsevier B.V.
Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe
NASA Astrophysics Data System (ADS)
Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.
2012-02-01
A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.
Singh, Kanwarpal; Reddy, Rohith; Sharma, Gargi; Verma, Yogesh; Gardecki, Joseph A; Tearney, Guillermo
2018-03-01
Endoscopic optical coherence tomography probes suffer from various artifacts due to dispersion imbalance and polarization mismatch between reference and sample arm light. Such artifacts can be minimized using a common path approach. In this work, we demonstrate a miniaturized common path probe for optical coherence tomography using an inline fiber mirror. A common path optical fiber probe suitable for performing high-resolution endoscopic optical coherence tomography imaging was developed. To achieve common path functionality, an inline fiber mirror was fabricated using a thin gold layer. A commercially available swept source engine was used to test the designed probe in a cadaver human coronary artery ex vivo. We achieved a sensitivity of 104 dB for this probe using a swept source optical coherence tomography system. To test the probe, images of a cadaver human coronary artery were obtained, demonstrating the quality that is comparable to those obtained by OCT systems with separate reference arms. Additionally, we demonstrate recovery of ranging depth by use of a Michelson interferometer in the detection path. We developed a miniaturized monolithic inline fiber mirror-based common path probe for optical coherence tomography. Owing to its simplicity, our design will be helpful in endoscopic applications that require high-resolution probes in a compact form factor while reducing system complexity. Lasers Surg. Med. 50:230-235, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Discrepancy between culture and DNA probe analysis for the detection of periodontal bacteria.
van Steenbergen, T J; Timmerman, M F; Mikx, F H; de Quincey, G; van der Weijden, G A; van der Velden, U; de Graaff, J
1996-10-01
The purpose of this study was to compare a commercially available DNA probe technique with conventional cultural techniques for the detection of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis and Prevotella intermedia in subgingival plaque samples. Samples from 20 patients with moderate to severe periodontitis were evaluated at baseline and during a 15 months period of periodontal treatment. Paperpoints from 4 periodontal pockets per patient were forwarded to Omnigene for DNA probe analysis, and simultaneously inserted paperpoints from the same pockets were analyzed by standard culture techniques. In addition, mixed bacterial samples were constructed harbouring known proportions of 25 strains of A. actinomycetemcomitans, P. gingivalis and P. intermedia each. A relatively low concordance was found between both methods. At baseline a higher detection frequency was found for A. actinomycetemcomitans and P. gingivalis for the DNA probe technique; for P. intermedia the detection frequency by culture was higher. For A. actinomycetemcomitans, 21% of the culture positive samples was positive with the DNA probe. Testing the constructed bacterial samples with the DNA probe method resulted in about 16% false positive results for the 3 species tested. Furthermore, 40% of P. gingivalis strains were not detected by the DNA probe. The present data suggest that at least part of the discrepancies found between the DNA probe technique used and cultural methods are caused by false positive and false negative DNA probe results. Therefore, the value of this DNA probe method for the detection of periodontal pathogens is questionable.
Varao-Sousa, Trish L; Kingstone, Alan
2018-06-26
Mind wandering (MW) reports often rely on individuals responding to specific external thought probes. Researchers have used this probe-caught method almost exclusively, due to its reliability across a wide range of testing situations. However, it remains an open question whether the probe-caught MW rates in more complex settings converge with those for simpler tasks, because of the rather artificial and controlled nature of the probe-caught methodology itself, which is shared across the different settings. To address this issue, we measured MW in a real-world lecture, during which students indicated whether they were mind wandering by simply catching themselves (as one would normally do in real life) or by catching themselves and responding to thought probes. Across three separate lectures, self-caught MW reports were stable and unaffected by the inclusion of MW probes. That the probe rates were similar to those found in prior classroom research and did not affect the self-caught MW rates strongly suggests that the past consistency of probe-caught MW rates across a range of different settings is not an artifact of the thought-probe method. Our study also indicates that the self-caught MW methodology is a reliable way to acquire MW data. The extension of measurement techniques to include students' self-caught reports provides valuable information about how to successfully and naturalistically monitor MW in lecture settings, outside the laboratory.
Salden, O A E; van Everdingen, W M; Spee, R; Doevendans, P A; Cramer, M J
2018-03-27
Stress echocardiography (SE) has recently regained momentum as an important diagnostic tool for the assessment of both ischemic and non-ischemic heart disease. Performing SE during physical exercise is challenging due to a suboptimal patient position and vigorous movements of the patient's chest. This hampers a stable ultrasound position and reduces the diagnostic performance of SE. A stable ultrasound probe position would facilitate producing high quality images during continuous measurements. With Probefix (Usono, Eindhoven, The Netherlands), a newly developed tool to fixate the ultrasound probe to the patient's chest, stabilization of the probe during physical exercise is possible. The technique of SE with the Probefix and its' feasibility are evaluated in a small pilot study. Probefix fixates the ultrasound probe to the patient's chest, using two chest straps and a fixation device. The ultrasound probe position and angle may be altered with a relative high degree of freedom. We tested the Probefix for continuous echocardiographic imaging in 12 study subjects during supine and upright ergometer stress tests. One patient was unable to perform exercise and in two study subjects good quality images were not achieved. In the other patients (82%) a stable probe position was obtained, with subsequent good quality echocardiographic images during SE. We have demonstrated the feasibility of the Probefix support during ergometer tests in supine and upright positions and conclude that this external fixator may facilitate continuous monitoring of cardiac function in a group of patients.
Biliary lithotripsy can be enhanced with proper ultrasound probe position.
Affronti, J; Flournoy, T; Akers, S; Baillie, J
1992-04-01
We have demonstrated in our in vitro system that an extracorporeal lithotripter utilizing a movable ultrasound probe can fragment gallstones more effectively when the ultrasound probe is not partially blocking shock waves. Using a pressure transducer we measured the pressures in the focal volume of a Wolf Piezolith 2300 lithotripter with the ultrasound probe fully extended and fully retracted. We also chose 12 pairs of twin gallstones, each taken from the same gallbladder. One stone from each pair was subjected to shock waves while the ultrasound probe was fully extended and the other treated while the probe was fully retracted. Shock wave pressures (which are converted to a measurable voltage output by our transducer) were clearly lower when the ultrasound probe was extended (5.45 volts; SEM = 0.10 volts) as compared to when the ultrasound scanner was retracted (6.7 volts: SEM = 0.08 volts). Significantly more shock waves were required to completely fragment stones when the ultrasound scanner was extended than when it was retracted (p = 0.01 using the nonparametric Wilcoxon's signed rank test). These results show that, in the lithotripter tested, an extended in-line ultrasound scanner can partially block shock waves. Retraction of an extendible ultrasound probe may enhance stone fragmentation when operating at the highest shock wave intensity.
NASA Astrophysics Data System (ADS)
Shevchenko, Svetlana Yu.; Melnik, Yury A.; Smirnov, Andrey E.; Htet, Wai Yan Min
2018-03-01
Temperature dependences of heat transfer coefficients of liquid and gaseous quenching media were determined using a gradient probe and prismatic probe of more simple design. The probes of two different designs were tested in the same conditions. Analysis of heat transfer coefficients showed good agreement between the data obtained. The tests were carried out with liquid and gaseous quenching media: water, polymer quenchant, quenching oil and high-pressure nitrogen. Methods of mathematical modeling of steel samples quenching show the adequacy of the results.
NASA Technical Reports Server (NTRS)
Phillips, G. B.; Pace, V. A., Jr.
1972-01-01
The sampler utilizes permanent magnets and soft metal pole pieces to connect the cone/filter assembly to the sampling head and vacuum supply. The cone/filter assembly is packaged in a plastic container and presterilized so that the need for any human contact during the sampling procedure is completely eliminated. Microbiological tests have demonstrated that the sampling efficiency is not affected by the magnetic coupling apparatus and that the probe appears to function as efficiently as the conventional plastic and Sandia vacuum probes.
Test systems of the STS-XYTER2 ASIC: from wafer-level to in-system verification
NASA Astrophysics Data System (ADS)
Kasinski, Krzysztof; Zubrzycka, Weronika
2016-09-01
The STS/MUCH-XYTER2 ASIC is a full-size prototype chip for the Silicon Tracking System (STS) and Muon Chamber (MUCH) detectors in the new fixed-target experiment Compressed Baryonic Matter (CBM) at FAIR-center, Darmstadt, Germany. The STS assembly includes more than 14000 ASICs. The complicated, time-consuming, multi-step assembly process of the detector building blocks and tight quality assurance requirements impose several intermediate testing to be performed for verifying crucial assembly steps (e.g. custom microcable tab-bonding before wire-bonding to the PCB) and - if necessary - identifying channels or modules for rework. The chip supports the multi-level testing with different probing / contact methods (wafer probe-card, pogo-probes, in-system tests). A huge number of ASICs to be tested restricts the number and kind of tests possible to be performed within a reasonable time. The proposed architectures of test stand equipment and a brief summary of methodologies are presented in this paper.
RF Testing Of Microwave Integrated Circuits
NASA Technical Reports Server (NTRS)
Romanofsky, R. R.; Ponchak, G. E.; Shalkhauser, K. A.; Bhasin, K. B.
1988-01-01
Fixtures and techniques are undergoing development. Four test fixtures and two advanced techniques developed in continuing efforts to improve RF characterization of MMIC's. Finline/waveguide test fixture developed to test submodules of 30-GHz monolithic receiver. Universal commercially-manufactured coaxial test fixture modified to enable characterization of various microwave solid-state devices in frequency range of 26.5 to 40 GHz. Probe/waveguide fixture is compact, simple, and designed for non destructive testing of large number of MMIC's. Nondestructive-testing fixture includes cosine-tapered ridge, to match impedance wavequide to microstrip. Advanced technique is microwave-wafer probing. Second advanced technique is electro-optical sampling.
Riou, Virginie; Périot, Marine; Biegala, Isabelle C
2017-01-01
Oligonucleotide probes are increasingly being used to characterize natural microbial assemblages by Tyramide Signal Amplification-Fluorescent in situ Hybridization (TSA-FISH, or CAtalysed Reporter Deposition CARD-FISH). In view of the fast-growing rRNA databases, we re-evaluated the in silico specificity of eleven bacterial and eukaryotic probes and competitor frequently used for the quantification of marine picoplankton. We performed tests on cell cultures to decrease the risk for non-specific hybridization, before they are used on environmental samples. The probes were confronted to recent databases and hybridization conditions were tested against target strains matching perfectly with the probes, and against the closest non-target strains presenting one to four mismatches. We increased the hybridization stringency from 55 to 65% formamide for the Eub338+EubII+EubIII probe mix to be specific to the Eubacteria domain. In addition, we found that recent changes in the Gammaproteobacteria classification decreased the specificity of Gam42a probe, and that the Roseo536R and Ros537 probes were not specific to, and missed part of the Roseobacter clade. Changes in stringency conditions were important for bacterial probes; these induced, respectively, a significant increase, in Eubacteria and Roseobacter and no significant changes in Gammaproteobacteria concentrations from the investigated natural environment. We confirmed the eukaryotic probes original conditions, and propose the Euk1209+NChlo01+Chlo02 probe mix to target the largest picoeukaryotic diversity. Experiences acquired through these investigations leads us to propose the use of seven steps protocol for complete FISH probe specificity check-up to improve data quality in environmental studies.
Reproducibility of the cutoff probe for the measurement of electron density
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, D. W.; Oh, W. Y.; You, S. J., E-mail: sjyou@cnu.ac.kr
2016-06-15
Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e.,more » there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.« less
Deb, Sanchali; Tang, Shou-jiang; Abell, Thomas L.; McLawhorn, Tyler; Huang, Wen-Ding; Lahr, Christopher; To, S.D. Filip; Easter, Julie; Chiao, J.-C.
2016-01-01
Background Gastric stimulation via high-frequency, low-energy pulses can provide an effective treatment for gastric dysmotility; however, the current commercially available device requires surgical implantation for long-term stimulation and is powered by a nonrechargeable battery. Objective To test and describe endoscopic implantation techniques and testing of stimulation of a novel, wireless, batteryless, gastric electrical stimulation (GES) device. Design Endoscopic gastric implantation techniques were implemented, and in vivo gastric signals were recorded and measured in a non-survival swine model (n = 2; 50-kg animals). Intervention Five novel endoscopic gastric implantation techniques and stimulation of a novel, wireless, batteryless, GES device were tested on a non-survival swine model. Main Outcome Measurements Feasibility of 5 new endoscopic gastric implantation techniques of the novel, miniature, batteryless, wireless GES device while recording and measurement of in vivo gastric signals. Results All 5 of the novel endoscopic techniques permitted insertion and securing of the miniaturized gastrostimulator. By the help of these methods and miniaturization of the gastrostimulator, successful GES could be provided without any surgery. The metallic clip attachment was restricted to the mucosal surface, whereas the prototype tacks, prototype spring coils, percutaneous endoscopic gastrostomy wires/T-tag fasteners, and submucosal pocket endoscopic implantation methods attach the stimulator near transmurally or transmurally to the stomach. They allow more secure device attachment with optimal stimulation depth. Limitations Non-survival pig studies. Conclusion These 5 techniques have the potential to augment the utility of GES as a treatment alternative, to provide an important prototype for other dysmotility treatment paradigms, and to yield insights for new technological interfaces between non-invasiveness and surgery. PMID:22726478
Autonomous Scanning Probe Microscopy in Situ Tip Conditioning through Machine Learning.
Rashidi, Mohammad; Wolkow, Robert A
2018-05-23
Atomic-scale characterization and manipulation with scanning probe microscopy rely upon the use of an atomically sharp probe. Here we present automated methods based on machine learning to automatically detect and recondition the quality of the probe of a scanning tunneling microscope. As a model system, we employ these techniques on the technologically relevant hydrogen-terminated silicon surface, training the network to recognize abnormalities in the appearance of surface dangling bonds. Of the machine learning methods tested, a convolutional neural network yielded the greatest accuracy, achieving a positive identification of degraded tips in 97% of the test cases. By using multiple points of comparison and majority voting, the accuracy of the method is improved beyond 99%.
Long working distance incoherent interference microscope
Sinclair, Michael B [Albuquerque, NM; De Boer, Maarten P [Albuquerque, NM
2006-04-25
A full-field imaging, long working distance, incoherent interference microscope suitable for three-dimensional imaging and metrology of MEMS devices and test structures on a standard microelectronics probe station. A long working distance greater than 10 mm allows standard probes or probe cards to be used. This enables nanometer-scale 3-dimensional height profiles of MEMS test structures to be acquired across an entire wafer while being actively probed, and, optionally, through a transparent window. An optically identical pair of sample and reference arm objectives is not required, which reduces the overall system cost, and also the cost and time required to change sample magnifications. Using a LED source, high magnification (e.g., 50.times.) can be obtained having excellent image quality, straight fringes, and high fringe contrast.
Festini, Sara B; Reuter-Lorenz, Patricia A
2014-03-01
Proactive interference (PI) occurs when previously learned information interferes with new learning. In a working memory task, PI induces longer response times and more errors to recent negative probes than to new probes, presumably because the recent probe's familiarity invites a "yes" response. Warnings, longer intertrial intervals, and the increased contextual salience of the probes can reduce but not eliminate PI, suggesting that cognitive control over PI is limited. Here we tested whether control exerted in the form of intentional forgetting performed during working memory can reduce the magnitude of PI. In two experiments, participants performed a working memory task with directed-forgetting instructions and the occasional presentation of recent probes. Surprise long-term memory testing indicated better memory for to-be-remembered than for to-be-forgotten items, documenting the classic directed-forgetting effect. Critically, in working memory, PI was virtually eliminated for recent probes from prior to-be-forgotten lists, as compared to recent probes from prior to-be-remembered lists. Thus cognitive control, when executed via directed forgetting, can reduce the adverse and otherwise persistent interference from familiarity, an effect that we attribute to attenuated memory representations of the to-be-forgotten items.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diaz, Aaron A.; Chamberlin, Clyde E.; Edwards, Matthew K.
This section of the Joint summary technical letter report (TLR) describes work conducted at the Pacific Northwest National Laboratory (PNNL) during FY 2016 (FY16) on the under-sodium viewing (USV) PNNL project 58745, work package AT-16PN230102. This section of the TLR satisfies PNNL’s M3AT-16PN2301025 milestone and is focused on summarizing the design, development, and evaluation of two different phased-array ultrasonic testing (PA-UT) probe designs—a two-dimensional (2D) matrix phased-array probe, and two one-dimensional (1D) linear array probes, referred to as serial number 4 (SN4) engineering test units (ETUs). The 2D probe is a pulse-echo (PE), 32×2, 64-element matrix phased-array ETU. The 1Dmore » probes are 32×1 element linear array ETUs. This TLR also provides the results from a performance demonstration (PD) of in-sodium target detection trials at 260°C using both probe designs. This effort continues the iterative evolution supporting the longer term goal of producing and demonstrating a pre-manufacturing prototype ultrasonic probe that possesses the fundamental performance characteristics necessary to enable the development of a high-temperature sodium-cooled fast reactor (SFR) inspection system for in-sodium detection and imaging.« less
Thermal Threshold Testing for Evaluation of Analgesics in New Zealand White Rabbits
Barter, Linda S; Kwiatkowski, Anna
2013-01-01
We adapted a thermal analgesiometric device developed for cats for use in unrestrained rabbits. A probe composed of an electrical element and temperature sensor was held against shaved skin by using an elasticized band placed circumferentially around the thorax. An inflated bladder located between the probe and elastic maintained constant contact between probe and skin. The probe was heated until the rabbit displayed a behavioral reaction or the safety cutoff of 55 °C was reached. Threshold temperatures in unmedicated rabbits were stable over a 5-h period provided that tests were 15 min or more apart. Careful acclimation and testing resulted in no false-negative responses, and sham testing did not produce false-positive results. When compared with baseline values, thermal thresholds were significantly increased from 30 to 240 min, but not 300 min, after the administration of morphine at 3 mg/kg. Administration of equivalent volumes of saline via the same route had no effect on thermal threshold. This device may be suitable for investigating analgesic pharmacology in rabbits. PMID:23562032
Coefficient of friction: tribological studies in man - an overview.
Sivamani, Raja K; Goodman, Jack; Gitis, Norm V; Maibach, Howard I
2003-08-01
Compared to other studies of skin, relatively few studies have focused on the friction of skin. This work reviews existing skin friction, emphasizing test apparatuses and parameters that have added to information regarding the friction coefficient. This review also outlines what factors are important to consider in future friction studies. Past studies have utilized numerous designs for a test apparatus, including probe geometry and material, as well as various probe motions (rotational vs. linear). Most tests were performed in vivo; a few were performed in vitro and on porcine skin. Differences in probe material, geometry and smoothness affect friction coefficient measurements. An increase in skin hydration, either through water or through moisturizer application, increases its friction coefficient; a decrease in skin hydration, either through clinical dermatitis or through alcohol addition, decreases the coefficient. Differences are present between anatomical sites. Conflicting results are found regarding age and no differences are apparent as a result of gender or race. Skin friction appears to be dependent on several factors - such as age, anatomical site and skin hydration. The choice of the probe and the test apparatus also influence the measurement.
Bias in masked word identification: unconscious influences of repetition priming.
Masson, Michael E J
2002-12-01
The beneficial influence of a prior study episode on subsequent identification of a word includes a large bias component, revealed in the forced-choice variant of the masked word identification test. In that type of test, subjects show a preference for a studied probe over a nonstudied probe, regardless of which one matches the masked target word. The forced-choice test was used in the present experiments to test the possibility that this bias effect is due to conscious recollection. Results show that bias was strongly attenuated (1) by changes in modality between study and test, and (2) under certain conditions, by using a conceptually driven study task. The bias effect was found only when probes were orthographically similar to one another, as predicted by the counter model (Ratcliff & McKoon, 1997). These results provide strong evidence that the bias effect is not mediated by conscious recollection.
Bovesecchi, G; Coppa, P; Pistacchio, S
2018-05-01
A new thermal conductivity probe for high temperature (HT-TCP) has been built and tested. Its design and construction procedure are adapted from the ambient temperature thermal conductivity probe (AT-TCP) due to good performance of the latter device. The construction procedure and the preliminary tests are accurately described. The probe contains a Pt wire as a heater and a type K thermocouple (TC) as a temperature sensor, and its size is so small (0.6 mm in diameter and 60 mm in length) as to guarantee a length to diameter ratio of about 100. Calibration tests with glycerol for temperatures between 0 °C and 60 °C have shown good agreement with literature data, within 3%. Preliminary tests were also carried on a ternary molten salt for Concentrated Solar Power (CSP) (18% in mass of NaNO 3 , 52% KNO 3 , and 30% LiNO 3 ) at 120 °C and 150 °C. Obtained results are within λ range of the Hitec ® salt (53% KNO 3 , 7% NaNO 3 , 40% NaNO 2 ). Unfortunately, at the higher temperature tested (200 °C), the viscosity of the salt highly decreases, and free convection starts, making the measurements unreliable.