An Ultrasonographic Periodontal Probe
NASA Astrophysics Data System (ADS)
Bertoncini, C. A.; Hinders, M. K.
2010-02-01
Periodontal disease, commonly known as gum disease, affects millions of people. The current method of detecting periodontal pocket depth is painful, invasive, and inaccurate. As an alternative to manual probing, an ultrasonographic periodontal probe is being developed to use ultrasound echo waveforms to measure periodontal pocket depth, which is the main measure of periodontal disease. Wavelet transforms and pattern classification techniques are implemented in artificial intelligence routines that can automatically detect pocket depth. The main pattern classification technique used here, called a binary classification algorithm, compares test objects with only two possible pocket depth measurements at a time and relies on dimensionality reduction for the final determination. This method correctly identifies up to 90% of the ultrasonographic probe measurements within the manual probe's tolerance.
Kelbauskiene, Solveiga; Baseviciene, Nomeda; Goharkhay, Kawe; Moritz, Andreas; Machiulskiene, Vita
2011-07-01
In 30 patients with periodontitis, a total of 278 teeth exhibiting bleeding on probing, subgingival calculus, and a probing depth between 3-6 mm were examined. For each participant, two treatment types were alternatively applied on the contralateral quadrants: scaling and root planing (SRP) as control, and SRP followed by Er,Cr:YSGG laser application (SRP+laser), as a test method. Five clinical parameters: plaque level, bleeding on probing, probing depth, gingival recession and clinical attachment level were examined at baseline and at 2, 3, 6, 12 months after treatment. Of the total of 1,668 sites examined in all patients, 1,088 sites were found with a probing depth of 3-6 mm. In these sites, differences in clinical parameters between SRP and SRP+laser-treated quadrants were analyzed, assuming the level of p < 0.05 as significant. After 2 months from baseline, the mean probing depth reduction and the clinical attachment level gain were significantly greater in SRP+laser than in SRP quadrants, and remained so throughout the study (p < 0.001). A marked reduction of the bleeding scores occurred in all examined sites, irrespective of the treatment method. However, after 12 months, significantly less teeth exhibited bleeding on probing in SRP+laser quadrants than in SRP quadrants (p < 0.001). The mean plaque and gingival recession levels did not differ between the SRP and SRP+laser quadrants neither before nor after the treatment. The periodontal procedures either using Er,Cr:YSGG laser after SRP or SRP alone, lead to significant improvements in all clinical parameters investigated. However, laser application, as an adjunct to SRP, appeared to be more advantageous.
Johannsen, Annsofi; Tellefsen, Monica; Wikesjö, Ulf; Johannsen, Gunnar
2009-09-01
The aim of the present study was to evaluate the adjunctive effect of the local application of a hyaluronan gel to scaling and root planing in the treatment of chronic periodontitis. Twelve patients with chronic periodontitis were recruited to participate in a study with a split-mouth design and provided informed consent. Plaque formation and bleeding on probing were evaluated pretreatment (baseline) and at 1, 4, and 12 weeks post-treatment. Probing depths and attachment levels were evaluated at baseline and at 12 weeks. The patients received full-mouth scaling and root planing. A hyaluronan gel was administered subgingivally in the test sites at baseline and after 1 week. Significant differences between test and control were evaluated using the paired t test, repeated-measures analysis of variance (Wilks lambda), and a non-parametric Wilcoxon signed-rank test. A significant reduction in bleeding on probing scores and probing depths was observed in both groups at 12 weeks (P <0.05). Significantly lower bleeding on probing scores were observed in the hyaluronan group compared to control at 12 weeks (P <0.05). Mean probing depth reductions between baseline and 12 weeks were 1.0 +/- 0.3 mm and 0.8 +/- 0.2 mm for the hyaluronan and control groups, respectively. The difference between the groups was statistically significant (P <0.05). The local application of hyaluronan gel in conjunction with scaling and root planing may have a beneficial effect on periodontal health in patients with chronic periodontitis.
Levy, Rustin M.; Giannobile, William V.; Feres, Magda; Haffajee, Anne D.; Smith, Claire; Socransky, Sigmund S.
2008-01-01
The purpose of this investigation was to examine the clinical and microbiologic effects of apically repositioned flap surgery. Eighteen patients with chronic periodontitis received initial preparation (IP) including scaling and root planing, followed at 3 months by apically repositioned flap surgery at sites with pocket depth > 4 mm. Subjects were monitored clinically and microbiologically at baseline, 3 months after IP, and at 3, 6, 9, and 12 months postsurgery. Clinical assessments of plaque accumulation, gingival redness, suppuration, bleeding on probing, pocket depth, and attachment level were made at six sites per tooth. Subgingival plaque samples were taken from the mesial aspect of each tooth, and the presence and levels of 40 subgingival taxa were determined using checkerboard DNA-DNA hybridization. Significant reductions were seen in mean pocket depth and percentage of sites exhibiting gingival redness and bleeding on probing in both sites that received IP only and in sites receiving IP followed by surgery. Mean attachment level increased significantly for both sets of sites, but the increase was greater at the surgically treated sites. The total DNA probe counts were significantly reduced at sites in both treatment groups. At surgically treated sites, 19 of 40 taxa were significantly reduced posttherapy. At sites receiving IP only, 16 species were significantly reduced over time. While there were some reductions in mean counts after IP in this site group, the major reductions occurred after the surgical phase in these patients, even though these particular sites did not receive surgical therapy. The reduction in pocket depth by surgical means and the associated decrease in reservoirs of periodontal pathogens may be important in achieving sustained periodontal stability. PMID:12186343
Bevilacqua, Lorenzo; Eriani, Jessica; Serroni, Ilde; Liani, Giuliana; Borelli, Violetta; Castronovo, Gaetano; Di Lenarda, Roberto
2012-01-01
Summary Aims The aim of this clinical trial was to compare clinical and biochemical healing outcomes following ultrasonic mechanical instrumentation versus ultrasonic mechanical instrumentation associated with topical subgingival application of amino acids and sodium hyaluronate gel. Methods Eleven systemically healthy subjects with moderate-severe chronic periodontitis, who had four sites with pocket probing depth and clinical attachment level greater than or equal to 5 mm were randomly assigned to two different types of treatment: two pockets were treated with ultrasonic debridement (Control Group) and two pockets with ultrasonic mechanical instrumentation associated with 0,5 ml of amino acids and sodium hyaluronate gel (Test Group). Probing depth, clinical attachment level, plaque index and bleeding on probing were recorded at baseline, 45 and 90 days. Levels of calprotectin and myeloperoxidase activity in gingival crevicular fluid were assessed at baseline and on day 7 and 45. Results Statistical significance was found between baseline and day 45 in relation to probing depth reduction and bleeding on probing between groups for both of the tested treatments. Significant reductions in μg/sample of calprotectin and myeloperoxidase were found after 1-week and an increase at 45 days in both groups. There were no statistically significant differences between other variables evaluated in this study. Conclusions These data suggest that subgingival application of hyaluronic acid following ultrasonic mechanical instrumentation is beneficial for improving periodontal parameters. PMID:23087790
Kumari, Minal; Martande, Santosh S; Pradeep, Avani R
2017-05-01
Statins are known to have a beneficial effect in the treatment of chronic periodontitis (CP). The current study was designed to investigate the effectiveness of a 1.2% atorvastatin (ATV) local drug delivery system as an adjunct to scaling and root planing (SRP) in the treatment of intrabony defects (IBD) in CP among smokers. Seventy-one smokers with CP were categorized into two treatment groups: SRP + 1.2% ATV gel and SRP + placebo gel. Clinical parameters, modified sulcus bleeding index, probing depth, and clinical attachment level were recorded at baseline before SRP and at 3, 6, and 9 months. At baseline, 6 months, and 9 months, the percentage of radiographic defect depth reduction was determined using computer-aided software. The mean probing depth reduction and mean clinical attachment level gain were found to be greater in the ATV group than the placebo group at 3, 6, and 9 months. A significantly greater mean percentage of radiographic defect depth reduction was found in the ATV group compared to the placebo group after 9 months. The ATV local drug delivery as an adjunct to SRP can be used in the treatment of IBD in CP among smokers. © 2016 John Wiley & Sons Australia, Ltd.
Effect of platelet-rich plasma in the treatment of periodontal intrabony defects in humans.
Ouyang, Xiang-ying; Qiao, Jing
2006-09-20
Platelet-rich plasma (PRP) is a kind of natural source of autologous growth factors, and has been used successfully in medical community. However, the effect of PRP in periodontal regeneration is not clear yet. This study was designed to evaluate the effectiveness of PRP as an adjunct to bovine porous bone mineral (BPBM) graft in the treatment of human intrabony defects. Seventeen intrabony defects in 10 periodontitis patients were randomly treated either with PRP and BPBM (test group, n = 9) or with BPBM alone (control group, n = 8). Clinical parameters were evaluated including changes in probing depth, relative attachment level (measured by Florida Probe and a stent), and bone probing level between baseline and 1 year postoperatively. Standardized periapical radiographs of each defect were taken at baseline, 2 weeks, and 1 year postoperatively, and analyzed by digital subtraction radiography (DSR). Both treatment modalities resulted in significant attachment gain, reduction of probing depth, and bone probing level at 1-year post-surgery compared to baseline. The test group exhibited statistically significant improvement compared to the control sites in probing depth reduction: (4.78 +/- 0.95) mm versus (3.48 +/- 0.41) mm (P < 0.01); clinical attachment gain: (4.52 +/- 1.14) mm versus (2.85 +/- 0.80) mm (P < 0.01); bone probing reduction: (4.56 +/- 1.04) mm versus (2.88 +/- 0.79) mm (P < 0.01); and defect bone fill: (73.41 +/- 14.78)% versus (47.32 +/- 11.47)% (P < 0.01). DSR analysis of baseline and 1 year postoperatively also showed greater radiographic gains in alveolar bone mass in the test group than in the control group: gray increase (580 +/- 50) grays versus (220 +/- 32) grays (P = 0.0001); area with increased gray were (5.21 +/- 1.25) mm(2) versus (3.02 +/- 1.22) mm(2) (P = 0.0001). The treatment with a combination of PRP and BPBM led to a significantly favorable clinical improvement in periodontal intrabony defects compared to using BPBM alone. Further studies are necessary to assess the long-term effectiveness of PRP, and a larger sample size is needed.
Radiographic bone fill following debridement of a periodontal abscess. A case report.
Khocht, A; Faldu, M G
1998-01-01
A periodontal abscess often develops in association with deepened periodontal pockets. Traditional management is by establishing drainage and prescribing antibiotics. This is usually followed by surgical pocket reduction. This case report discusses the remarkable healing of a periodontal abscess by establishing drainage alone without resorting to surgical pocket reduction. A 42-year-old white male presented with swollen gingivae associated with the mesiolingual of tooth #23. Increased probing depth and suppuration were evident. Radiographic bone loss on mesial #23 was present. A diagnosis of periodontal abscess was established. The abscess was drained through the orifice of the pocket. The patient failed to return for follow-up as instructed. A year later, the patient came back. Clinical evaluation showed healthy gingival tissues with probing depth of 3 mm on the mesiolingual of tooth #23. Radiographic evaluation showed bone fill of the osseous defect on the mesial of #23. The results of this case suggest that sufficient time should be allowed for healing prior to surgical pocket reduction.
Campbell, K.M.; Root, R.; O'Day, P. A.; Hering, J.G.
2008-01-01
Arsenic (As) geochemistry and sorption behavior were measured in As- and iron (Fe)-rich sediments of Haiwee Reservoir by deploying undoped (clear) polyacrylamide gels and hydrous ferric oxide (HFO)-doped gels in a gel probe equilibrium sampler, which is a novel technique for directly measuring the effects of porewater composition on As adsorption to Fe oxides phases in situ. Arsenic is deposited at the sediment surface as As(V) and is reduced to As(III) in the upper layers of the sediment (0-8 cm), but the reduction of As(V) does not cause mobilization into the porewater. Dissolved As and Fe concentrations increased at depth in the sediment column driven by the reductive dissolution of amorphous Fe(III) oxyhydroxides and conversion to a mixed Fe(II, III) green rust-type phase. Adsorption of As and phosphorous (P) onto HFO-doped gels was inhibited at intermediate depths (10-20 cm), possibly due to dissolved organic or inorganic carbon, indicating that dissolved As concentrations were at least partially controlled by porewater composition rather than surface site availability. In sediments that had been recently exposed to air, the region of sorption inhibition was not observed, suggesting that prior exposure to air affected the extent of reductive dissolution, porewater chemistry, and As adsorption behavior. Arsenic adsorption onto the HFO-doped gels increased at depths >20 cm, and the extent of adsorption was most likely controlled by the competitive effects of dissolved phosphate. Sediment As adsorption capacity appeared to be controlled by changes in porewater composition and competitive effects at shallower depths, and by reductive dissolution and availability of sorption sites at greater burial depths. ?? 2008 American Chemical Society.
Kato, Shunsuke; Ammann, Markus; Huthwelker, Thomas; Paun, Cristina; Lampimäki, Markus; Lee, Ming-Tao; Rothensteiner, Matthäus; van Bokhoven, Jeroen A
2015-02-21
The redox property of ceria is a key factor in the catalytic activity of ceria-based catalysts. The oxidation state of well-defined ceria nanocubes in gas environments was analysed in situ by a novel combination of near-ambient pressure X-ray Photoelectron Spectroscopy (XPS) and high-energy XPS at a synchrotron X-ray source. In situ high-energy XPS is a promising new tool to determine the electronic structure of matter under defined conditions. The aim was to quantitatively determine the degree of cerium reduction in a nano-structured ceria-supported platinum catalyst as a function of the gas environment. To obtain a non-destructive depth profile at near-ambient pressure, in situ high-energy XPS analysis was performed by varying the kinetic energy of photoelectrons from 1 to 5 keV, and, thus, the probing depth. In ceria nanocubes doped with platinum, oxygen vacancies formed only in the uppermost layers of ceria in an atmosphere of 1 mbar hydrogen and 403 K. For pristine ceria nanocubes, no change in the cerium oxidation state in various hydrogen or oxygen atmospheres was observed as a function of probing depth. In the absence of platinum, hydrogen does not dissociate and, thus, does not lead to reduction of ceria.
Chen, Y-W; Lee, C-T; Hum, L; Chuang, S-K
2017-03-01
The extraction of an impacted third molar violates the surrounding soft and bony tissues. The surgeon's access to the tooth, for which there are various surgical approaches, has an important impact on the periodontium of the adjacent second molar. The aim of this review was to analyze the relationships between the different flap techniques and postoperative periodontal outcomes for the mandibular second molars (LM2) adjacent to the impacted mandibular third molars (LM3). An electronic search of MEDLINE and other databases was conducted to identify randomized controlled trials fulfilling the eligibility criteria. To assess the impact of flap design on the periodontal condition, the weighted mean difference of the probing depth reduction (WDPDR) and the weighted mean difference of the clinical attachment level gain (WDCAG) at the distal surface of LM2 were used as the primary outcomes. The results showed that, overall, the different flap techniques had no significant impact on the probing depth reduction (WDPDR -0.14mm, 95% confidence interval -0.44 to 0.17), or on the clinical attachment level gain (WDCAG 0.05mm, 95% confidence interval -0.84 to 0.94). However, a subgroup analysis revealed that the Szmyd and paramarginal flap designs may be the most effective in reducing the probing depth in impacted LM3 extraction, and the envelope flap may be the least effective. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Panda, Saurav; Sankari, Malaiappan; Satpathy, Anurag; Jayakumar, Doraiswamy; Mozzati, Marco; Mortellaro, Carmen; Gallesio, Giorgia; Taschieri, Silvio; Del Fabbro, Massimo
2016-05-01
Autologous platelet-rich fibrin (PRF) and barrier membranes in the treatment of intrabony defects in chronic periodontitis patients have shown significant clinical benefits. This study evaluates the additive effect of autologous PRF in combination with a barrier membrane versus the use of barrier membrane alone for the treatment of intrabony defects in chronic periodontitis patients. A randomized split-mouth design was used. Sixteen patients with 32 paired intrabony defects were included. In each patient 1 defect was treated using a resorbable collagen membrane along with PRF (test group) and the other defect by guided tissue regeneration alone (control group). The following clinical parameters were measured at baseline and after 9 months: plaque index, modified sulcus bleeding index, probing pocket depth, clinical attachment level, and gingival marginal level. The radiographic defect depth was also assessed at baseline and after 9 months. Test group showed a statistically significant improvement for probing depth (P = 0.002), clinical attachment level (P = 0.001), and radiographic defect depth (P < 0.001) after 9 months as compared with the control sites. Radiographic defect depth reduction was 58.19 ± 13.24% in the test group as compared with 24.86 ± 9.94% reduction in the control group. The adjunctive use of PRF in combination with barrier membrane is more effective in the treatment of intrabony defects in chronic periodontitis as compared with barrier membrane alone.
Kannan, Anitha Logaranjani; Bose, Buvaneshwari Birla; Muthu, Jananni; Perumalsamy, Rajapriya; Pushparajan, Saravanan; Namasivayam, Ambalavanan
2014-01-01
Context: Invasion of the bifurcation and trifurcation of the multi-rooted teeth resulting in furcation involvement is one of the serious complications of periodontitis. Aim: The purpose of the study was to evaluate the efficacy of combination therapy using anorganic bovine bone graft and resorbable guided tissue regeneration (GTR) membrane versus open flap debridement alone in the management of Grade II furcation defects in mandibular molars. Materials and Methods: The study included a total number of 20 sites in 10 patients with bilateral mandibular furcation defects, out of which 10 sites were treated as test group and 10 as control group. The test group was treated with combination therapy and the control group with open flap debridement alone. The parameters were recorded on 0 day (baseline), 90th day, and 180th day, which included vertical probing depth and horizontal probing depth of the furcation defect, clinical attachment level, and defect fill. Statistical Analysis Used: Mean and standard deviation were calculated for different variables in each study group at different time points. Mean values were compared by using Wilcoxon signed ranks test, after adjusting the P values for multiple comparison by using Bonferroni correction method. Results: Both the test and control groups showed a definitive improvement in clinical parameters, which was statistically significant. On comparison, the vertical probing depth showed significant reduction in the test group with a mean reduction of 3.1 ± 0.7 mm, when compared to the control group which showed a mean reduction of 1.5 ± 0.5 mm. The horizontal probing depth of furcation defects was also significantly reduced in the test group with a mean reduction of 2.2 ± 0.6 mm, when compared to the control group in which the mean reduction was 0.9 ± 0.3 mm. There was also significant gain in attachment level in the test group which showed a mean gain of 3.2 ± 0.6 mm, when compared to the control group which showed a gain of 1.2 ± 0.6 mm. Radiographic defect fill was found to be more in the test group with a mean gain of 2.0 ± 0.1 mm, when compared to the control group which showed a defect fill of 0.2 ± 0.1 mm. Conclusions: The results of this study demonstrated that the combined use of anorganic bovine bone graft and resorbable GTR membrane is effective than open flap debridement alone in the treatment of mandibular grade II furcation defects. PMID:25452926
Mellonig, James T; Valderrama, Pilar; Gregory, Holly J; Cochran, David L
2009-09-01
Enamel matrix derivative (EMD) is a composite of proteins that was demonstrated histologically to work as an adjunct to periodontal regenerative surgical therapy. The purpose of this study was to evaluate the clinical and histologic effects of EMD as an adjunct to scaling and root planing. Four patients with severe chronic periodontitis and scheduled to receive complete dentures were accrued. Probing depth and clinical attachment levels were obtained. Unlimited time was allowed for hand and ultrasonic instrumentation. A notch was placed in the root >or=1 to 2 mm from the apical extent of root planing. EMD was inserted into the pocket, and a periodontal dressing was placed. Patients were seen every 2 weeks for plaque control. At 6 months post-treatment, soft tissue measurements were repeated, and the teeth were removed en bloc and prepared for histomorphologic analysis. Probing depth reduction and clinical attachment level gain were obtained in three-fourths of the specimens. Three of the four specimens analyzed histologically demonstrated new cementum, bone, periodontal ligament, and connective tissue attachment coronal to the notch. In one specimen, the gingival margin had receded below the notch. The results were unexpected and may represent an aberration. However, the substantial reduction in deep probing depths and clinical attachment level gain in three of four specimens, in addition to the histologic findings of new cementum, new bone, a new periodontal ligament, and a new connective tissue attachment, suggest that EMD may be useful as an adjunct to scaling and root planing in single-rooted teeth.
Al Hulami, Hassan; Babay, Nadir; Awartani, Fatin; Anil, Sukumaran
2011-01-01
Background Locally delivered doxycycline is found to be effective in managing periodontitis as an adjunct to scaling and root planing. Aim To evaluate the effect of locally delivered doxycycline (10%) with scaling and root planing in the periodontal treatment of smokers and to compare it with scaling and root planing alone. Methods Twelve smokers with chronic periodontitis and a pocket depth (⩾5 mm) on posterior teeth that bleed on probing were selected. Patients were randomly assigned to scaling and root planing (SRP) or scaling and root planing followed by local application of doxycycline (SRP-D). Plaque, bleeding on probing, gingival recession, clinical attachment level (CAL), and probing depth (PD) were recorded at the baseline, 6 and 12 weeks. Results Both groups showed a significant reduction in Plaque, Bleeding on Probing and pocket depth at 6th and 12th week from the baseline. A statistically significant gain of attachment was observed in both groups after treatment. Even though the doxycycline group showed slightly higher attachment gain it was not statistically significant compared to the control group. Conclusion The observations of the study reveal that the additional benefit of topical application of doxycycline as an adjunct to scaling and root planing in smokers is not convincing. However, further clinical studies may be necessary to substantiate the present observations. PMID:23960508
John, Priya; Lazarus, Flemingson; Selvam, Arul; Prabhuji, Munivenkatappa Lakshmaiah Venkatesh
2015-01-01
Introduction PerioChip a bovine origin gelatine based CHX chip has shown beneficial effects in the management of Chronic Periodontitis. A new fish collagen based CHX chip similar to PerioChip is currently available; however this product has not been thoroughly researched. Aim The aim of the present study was to evaluate the effectiveness of a new Piscean collagen-based controlled-release chlorhexidine chip (CHX chip) as an adjunctive therapy to scaling and root planing (SRP). Settings and Design The study was conducted as a randomised, split-mouth, controlled clinical trial at Krishnadevaraya College of Dental Sciences, Bangalore, India. Materials and Methods In a split–mouth study involving 20 sites in 10 patients with chronic periodontitis, control sites received scaling and root planing and test sites received scaling and root planing (SRP) and the intrapocket CHX chip placement as an adjunct. Subgingival plaque samples were collected from both control and test sites at baseline, 11 days and 11 weeks and the anaerobic colony count were assessed. Clinical parameters that were recorded at baseline and 11 weeks were gingival index, Plaque index, Probing pocket depth (PPD), and Clinical attachment level (CAL). Plaque index was recorded additionally at 11 days. Results In the test group there was a statistically significant reduction in the total anaerobic colony count, gingival index and plaque scores from baseline as compared to control sites at all time intervals. An additional 0.8mm reduction in mean probing pocket depth was noted in the test group. Gain in Clinical attachment level was comparable in both groups. Conclusion The adjunctive use of the new collagen-based CHX chip yielded significant antimicrobial benefit accompanied by a reduction in probing depth and a clinical attachment level gain as compared to SRP alone. This suggests that it may be a useful treatment option of nonsurgical periodontal treatment of chronic periodontitis. PMID:26155567
Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Jixi, E-mail: lujixi@buaa.edu.cn; Qian, Zheng; Fang, Jiancheng
2015-08-15
This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjustmore » the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.« less
Management of Chronic Periodontitis Using Chlorhexidine Chip and Diode Laser-A Clinical Study.
Jose, Kachapilly Arun; Ambooken, Majo; Mathew, Jayan Jacob; Issac, Annie Valayil; Kunju, Ajithkumar Parachalil; Parameshwaran, Renjith Athirkandathil
2016-04-01
The use of adjuncts like chlorhexidine local delivery and diode laser decontamination have been found to improve the clinical outcomes of scaling and root planing in non-surgical periodontal therapy in patients with chronic periodontitis. To evaluate the effects of diode laser and chlorhexidine chip as adjuncts to scaling and root planing in the management of chronic periodontitis. The objective is to evaluate the outcome of chlorhexidine chip and diode laser as adjuncts to scaling and root planing on clinical parameters like Plaque Index, Gingival Index, probing pocket depth and clinical attachment level. Department of Periodontics. Randomized clinical trial with split mouth design. Fifteen chronic periodontitis patients having a probing pocket depth of 5mm-7mm on at least one interproximal site in each quadrant of the mouth were included in the study. After initial treatment, four sites in each patient were randomly subjected to scaling and root planing (control), chlorhexidine chip application (CHX chip group), diode laser (810 nm) decontamination (Diode laser group) or combination of both (Diode laser and chip group). Plaque Index (PI), Gingival Index (GI), probing pocket depth (PPD) and clinical attachment level (CAL) were assessed at baseline, one month and three months. Results were statistically analysed using paired T test, one-way ANOVA, Tukey's HSD test and repeated measure ANOVA. Post-treatment, the test and control sites showed a statistically significant reduction in PI, GI, PPD, and CAL. After three months, a mean PPD reduction of 1.47±0.52 mm in control group, 1.40±0.83 mm in diode laser group, 2.67±0.62 mm in CHX group, and 2.80± 0.77 mm in combination group was seen. The mean gain in CAL were 1.47±0.52 mm in the control group, 1.40±0.83 mm in diode laser group, 2.67± 0.49 mm in CHX group and 2.67± 0.82 mm in combination group respectively. The differences in PPD reduction and CAL gain between control group and CHX chip and combination groups were statistically significant (p<0.05) at three months, whereas, the diode laser group did not show any significant difference from the control group. Chlorhexidine local delivery alone or in combination with diode laser decontamination is effective in reducing probing pocket depth and improving clinical attachment levels when used as adjuncts to scaling and root planing in non-surgical periodontal therapy of patients with chronic periodontitis.
Management of Chronic Periodontitis Using Chlorhexidine Chip and Diode Laser-A Clinical Study
Ambooken, Majo; Mathew, Jayan Jacob; Issac, Annie Valayil; Kunju, Ajithkumar Parachalil; Parameshwaran, Renjith Athirkandathil
2016-01-01
Introduction The use of adjuncts like chlorhexidine local delivery and diode laser decontamination have been found to improve the clinical outcomes of scaling and root planing in non-surgical periodontal therapy in patients with chronic periodontitis. Aim To evaluate the effects of diode laser and chlorhexidine chip as adjuncts to scaling and root planing in the management of chronic periodontitis. The objective is to evaluate the outcome of chlorhexidine chip and diode laser as adjuncts to scaling and root planing on clinical parameters like Plaque Index, Gingival Index, probing pocket depth and clinical attachment level. Study and Design Department of Periodontics. Randomized clinical trial with split mouth design. Materials and Methods Fifteen chronic periodontitis patients having a probing pocket depth of 5mm-7mm on at least one interproximal site in each quadrant of the mouth were included in the study. After initial treatment, four sites in each patient were randomly subjected to scaling and root planing (control), chlorhexidine chip application (CHX chip group), diode laser (810 nm) decontamination (Diode laser group) or combination of both (Diode laser and chip group). Plaque Index (PI), Gingival Index (GI), probing pocket depth (PPD) and clinical attachment level (CAL) were assessed at baseline, one month and three months. Statistical analysis Results were statistically analysed using paired T test, one-way ANOVA, Tukey’s HSD test and repeated measure ANOVA. Results Post-treatment, the test and control sites showed a statistically significant reduction in PI, GI, PPD, and CAL. After three months, a mean PPD reduction of 1.47±0.52 mm in control group, 1.40±0.83 mm in diode laser group, 2.67±0.62 mm in CHX group, and 2.80± 0.77 mm in combination group was seen. The mean gain in CAL were 1.47±0.52 mm in the control group, 1.40±0.83 mm in diode laser group, 2.67± 0.49 mm in CHX group and 2.67± 0.82 mm in combination group respectively. The differences in PPD reduction and CAL gain between control group and CHX chip and combination groups were statistically significant (p<0.05) at three months, whereas, the diode laser group did not show any significant difference from the control group. Conclusion Chlorhexidine local delivery alone or in combination with diode laser decontamination is effective in reducing probing pocket depth and improving clinical attachment levels when used as adjuncts to scaling and root planing in non-surgical periodontal therapy of patients with chronic periodontitis. PMID:27190958
Kumari, Minal; Martande, Santosh S; Pradeep, A R; Naik, Savitha B
2016-11-01
The present study was designed to evaluate effectiveness of 1.2% atorvastatin (ATV) gel, as an adjunct to scaling and root planing (SRP) in the treatment of intrabony defects in chronic periodontitis (CP) in patients with type 2 diabetes mellitus (t2DM). Seventy-five patients were categorized into two treatment groups: 1) SRP plus 1.2% ATV and 2) SRP plus placebo. Clinical parameters including modified sulcus bleeding index, probing depth (PD), and relative attachment level (RAL) were recorded at baseline and 3, 6, and 9 months. Percentage radiographic defect depth reduction was evaluated using computer-aided software at baseline and 6 and 9 months. Mean PD reduction and mean RAL gain was greater in the ATV group than the placebo group at 3, 6, and 9 months. Furthermore, ATV group sites presented with a significantly greater percentage of radiographic defect depth reduction at 6 and 9 months. Locally delivered ATV was found to be effective in treatment of intrabony defects in CP in patients with t2DM.
Kudva, Praveen; Tabasum, Syeda Tawkhira; Shekhawat, Nirmal Kanwar
2011-01-01
Background: Evaluate the adjunctive use of locally delivered green tea catechin with scaling and root planing, as compared to scaling and root planing alone in the management of chronic periodontitis. Materials and Methods: Fourteen patients with two sites in the contralateral quadrants with probing pocket depth of 5–8mm were selected. Each of the sites was assessed for the plaque index, gingival index, and probing pocket depth at baseline and 21 days and for microbiological analysis at baseline, 1 week and 21 days. Test sites received scaling and root planing along with green tea catechin strips and control sites received scaling and root planning alone. Results: The result showed intercomparison of the plaque index and gingival index for test and control groups at 21 days was not significant with P>0.05, whereas the probing depth at 21 days was significant with P<0.001. Intercomparison between microbial results demonstrated a considerable reduction of occurrence of Aggregatibacter actinomycetemcomitans, Prevotella intermedia, Fusobacterium species and Capnocytophaga in test. Conclusion: Green tea catechin local delivery along with scaling and root planing is more effective than scaling and root planing alone. PMID:21772720
Banjar, Arwa Ahmed; Mealey, Brian L
2013-01-01
The goal of this study was to evaluate the effectiveness of demineralized bone matrix (DBM) putty, consisting of demineralized human bone allograft matrix in a carrier of bovine collagen and alginate, for the treatment of periodontal defects in humans. Twenty subjects with at least one site having a probing depth ≥ 6 mm and radiographic evidence of bony defect depth > 3 mm were included. The infrabony defects were grafted with DBM putty bone graft. The following clinical parameters were assessed at baseline and 6 months posttreatment: probing depth (PD), gingival recession (GR), and clinical attachment level (CAL). Bone fill was evaluated using transgingival probing and standardized radiographs taken at baseline and 6 months posttreatment. The 6-month evaluation showed a significant PD reduction of 3.27 ± 1.67 mm and clinical attachment gain of 2.27 ± 1.74 mm. Bone sounding measurements showed a mean clinical bone defect fill of 2.93 ± 1.87 mm and a mean radiographic bone fill of 2.55 ± 2.31 mm. The use of DBM putty was effective for treatment of periodontal bony defects in humans. Significant improvement in CAL, PD, and bone fill was observed at 6 months compared to baseline.
The Antimicrobial Photodynamic Therapy in the Treatment of Peri-Implantitis
Libotte, Fabrizio; Sabatini, Silvia; Grassi, Felice Roberto
2016-01-01
Introduction. The aim of this study is to demonstrate the effectiveness of addition of the antimicrobial photodynamic therapy to the conventional approach in the treatment of peri-implantitis. Materials and Methods. Forty patients were randomly assigned to test or control groups. Patients were assessed at baseline and at six (T1), twelve (T2), and twenty-four (T3) weeks recording plaque index (PlI), probing pocket depth (PPD), and bleeding on probing (BOP); control group received conventional periodontal therapy, while test group received photodynamic therapy in addition to it. Result. Test group showed a 70% reduction in the plaque index values and a 60% reduction in PD values compared to the baseline. BOP and suppuration were not detectable. Control group showed a significative reduction in plaque index and PD. Discussion. Laser therapy has some advantages in comparison to traditional therapy, with faster and greater healing of the wound. Conclusion. Test group showed after 24 weeks a better value in terms of PPD, BOP, and PlI, with an average pocket depth value of 2 mm, if compared with control group (3 mm). Our results suggest that antimicrobial photodynamic therapy with diode laser and phenothiazine chloride represents a reliable adjunctive treatment to conventional therapy. Photodynamic therapy should, however, be considered a coadjuvant in the treatment of peri-implantitis associated with mechanical (scaling) and surgical (grafts) treatments. PMID:27429618
Pradeep, Avani R; Patnaik, Kaushik; Nagpal, Kanika; Karvekar, Shruti; Ramamurthy, Bhaskar L; Naik, Savitha B; Suke, Deepak; Singh, Priyanka; Raju, Arjun
2016-08-01
Metformin (MF), used for the treatment of type 2 diabetes mellitus, has shown to possess properties favoring osteoblastic proliferation. The present study was designed to investigate the effectiveness of MF 1% gel as an adjunct to scaling and root planing in the treatment of intrabony defects in patients with chronic periodontitis. The study comprised 65 individuals divided into two groups: 1% MF with SRP and placebo gel with SRP. Clinical parameters were evaluated at baseline, 3 months, and 6 months; they included plaque index, modified sulcus bleeding index, probing depth (PD), and clinical attachment level (CAL). Intrabony defect depth (IBD) was evaluated at the end of 6 months using computer-aided software. The mean PD reduction, CAL gain, and IBD depth reduction were found to be greater in the MF group than in the placebo group at all visits. The percentage of defect depth reduction was significantly greater in the MF group (26.8 ± 5.52%) than in the placebo sites (4.79 ± 2.30%, P < 0.001). One percent MF was found to significantly improve clinical and radiographic parameters in intrabony defects in patients with chronic periodontitis. © 2015 Wiley Publishing Asia Pty Ltd.
Fiáth, Richárd; Beregszászi, Patrícia; Horváth, Domonkos; Wittner, Lucia; Aarts, Arno A. A.; Ruther, Patrick; Neves, Hercules P.; Bokor, Hajnalka; Acsády, László
2016-01-01
Recording simultaneous activity of a large number of neurons in distributed neuronal networks is crucial to understand higher order brain functions. We demonstrate the in vivo performance of a recently developed electrophysiological recording system comprising a two-dimensional, multi-shank, high-density silicon probe with integrated complementary metal-oxide semiconductor electronics. The system implements the concept of electronic depth control (EDC), which enables the electronic selection of a limited number of recording sites on each of the probe shafts. This innovative feature of the system permits simultaneous recording of local field potentials (LFP) and single- and multiple-unit activity (SUA and MUA, respectively) from multiple brain sites with high quality and without the actual physical movement of the probe. To evaluate the in vivo recording capabilities of the EDC probe, we recorded LFP, MUA, and SUA in acute experiments from cortical and thalamic brain areas of anesthetized rats and mice. The advantages of large-scale recording with the EDC probe are illustrated by investigating the spatiotemporal dynamics of pharmacologically induced thalamocortical slow-wave activity in rats and by the two-dimensional tonotopic mapping of the auditory thalamus. In mice, spatial distribution of thalamic responses to optogenetic stimulation of the neocortex was examined. Utilizing the benefits of the EDC system may result in a higher yield of useful data from a single experiment compared with traditional passive multielectrode arrays, and thus in the reduction of animals needed for a research study. PMID:27535370
Microlensed dual-fiber probe for depth-resolved fluorescence measurements
NASA Astrophysics Data System (ADS)
Choi, Hae Young; Ryu, Seon Young; Kim, Jae Young; Kim, Geon Hee; Park, Seong Jun; Lee, Byeong Ha; Chang, Ki Soo
2011-07-01
We propose and demonstrate a compact microlensed dual-fiber probe that has a good collection efficiency and a high depth-resolution ability for fluorescence measurements. The probe is formed with a conventional fusion splicer creating a common focusing lens on two fibers placed side by side. The collection efficiency of the fabricated probe was evaluated by measuring the fluorescence signal of a fresh ginkgo leaf. It was shown experimentally that the proposed probe could effectively collect the fluorescence signal with a six-fold increase compared to that of a general flat-tipped probe. The beam propagation method was used to design a probe with an optimized working distance and an improved resolving depth. It was found that the working distance depends mainly on the radius of curvature of the lens, whereas the resolving depth is determined by the core diameters of the illumination and collection fibers. The depth-resolved ability of probes with working distances of ~100 μm and 300 μm was validated by using a two-layer tissue phantom. The experimental results demonstrate that the microlensed dual-fiber probe has the potential to facilitate depth-resolved fluorescence detection of epithelial tissue.
Issac, Annie V; Mathew, Jayan Jacob; Ambooken, Majo; Kachappilly, Arun Jose; Pk, Ajithkumar; Johny, Thomas; Vk, Linith; Samuel, Anju
2015-08-01
Adjunctive use of professional subgingival irrigation with scaling and root planing (SRP) has been found to be beneficial in eradicating the residual microorganisms in the pocket. To evaluate the effect of ozonized water subgingival irrigation on microbiologic parameters and clinical parameters namely Gingival index, probing pocket depth, and clinical attachment level. Thirty chronic periodontitis patients with probing pocket depth ≥6mm on at least one tooth on contra lateral sides of opposite arches were included in the study. The test sites were subjected to ozonized water subgingival irrigation with subgingival irrigation device fitted with a modified subgingival tip. Control sites were subjected to scaling and root planing only. The following clinical parameters were recorded initially and after 4 weeks at the test sites and control sites. Plaque Index, Gingival Index, probing pocket depth, clinical attachment level. Microbiologic sampling was done for the test at the baseline, after scaling, immediately after ozonized water subgingival irrigation and after 4 weeks. In control sites microbiologic sampling was done at the baseline, after scaling and after 4 weeks. The following observations were made after 4 weeks. The results were statistically analysed using independent t-test and paired t-test. Test sites showed a greater reduction in pocket depth and gain in clinical attachment compared to control sites. The total anaerobic counts were significantly reduced by ozonized water subgingival irrigation along with SRP compared to SRP alone. Ozonized water subgingival irrigation can improve the clinical and microbiological parameters in patients with chronic periodontitis when used as an adjunct to scaling and root planing.
Fiáth, Richárd; Beregszászi, Patrícia; Horváth, Domonkos; Wittner, Lucia; Aarts, Arno A A; Ruther, Patrick; Neves, Hercules P; Bokor, Hajnalka; Acsády, László; Ulbert, István
2016-11-01
Recording simultaneous activity of a large number of neurons in distributed neuronal networks is crucial to understand higher order brain functions. We demonstrate the in vivo performance of a recently developed electrophysiological recording system comprising a two-dimensional, multi-shank, high-density silicon probe with integrated complementary metal-oxide semiconductor electronics. The system implements the concept of electronic depth control (EDC), which enables the electronic selection of a limited number of recording sites on each of the probe shafts. This innovative feature of the system permits simultaneous recording of local field potentials (LFP) and single- and multiple-unit activity (SUA and MUA, respectively) from multiple brain sites with high quality and without the actual physical movement of the probe. To evaluate the in vivo recording capabilities of the EDC probe, we recorded LFP, MUA, and SUA in acute experiments from cortical and thalamic brain areas of anesthetized rats and mice. The advantages of large-scale recording with the EDC probe are illustrated by investigating the spatiotemporal dynamics of pharmacologically induced thalamocortical slow-wave activity in rats and by the two-dimensional tonotopic mapping of the auditory thalamus. In mice, spatial distribution of thalamic responses to optogenetic stimulation of the neocortex was examined. Utilizing the benefits of the EDC system may result in a higher yield of useful data from a single experiment compared with traditional passive multielectrode arrays, and thus in the reduction of animals needed for a research study. Copyright © 2016 the American Physiological Society.
Sato, Shuichi; Ujiie, Hisashi; Ito, Koichi
2004-10-01
This case report describes the spontaneous correction of pathologic tooth migration and reduced infrabony pockets after nonsurgical periodontal therapy. A 3-mm diastema between the maxillary incisors was closed completely, and the mandibular teeth, which had migrated pathologically, returned to the optimal position. Clinical evaluation showed a significant reduction in probing depth, with increased clinical attachment and bone deposition demonstrated radiologically.
Kalash, D; Vovk, A; Huang, H; Aukhil, I; Wallet, S M; Shaddox, L M
2015-01-01
A previous study has shown that children with localized aggressive periodontitis (LAP) demonstrate a lipopolysaccharide (LPS) hyper-responsiveness in addition to elevated levels of systemic LPS when compared to periodontally healthy children. The purpose of this study was to evaluate whether periodontal therapy modulates systemic lipopolysaccharide levels and whether these levels may influence clinical outcomes. Peripheral blood samples and clinical parameters (probing depth [PD], clinical attachment levels [CAL], percent sites greater than four mm, bleeding on probing [BoP], and visible plaque [P]) were collected from 29 LAP patients prior to and at three, six, and 12 months following scaling and root planning and systemic antibiotics. Serum LPS levels were quantified using a chromogenic assay. Twenty-five patients were compliant with the prescribed antibiotic treatment and demonstrated a significant reduction in LPS as well as overall PD, CAL, and plaque at all time points post-therapy. Additionally LPS reductions correlated with reductions in PD, CAL, and plaque. Localized aggressive periodontitis therapy with antibiotics plays an important role in reducing systemic lipopolysaccharide levels. Since LPS is a key mediator of the LAP hyperinflammatory response, its systemic reduction is especially important for the successful management of these children.
Mellonig, James T; Valderrama, Pilar; Cochran, David L
2010-04-01
This study evaluated the clinical and histologic results of a calcium phosphate bone cement in the treatment of human periodontal intraosseous defects. Four patients with chronic advanced periodontitis in whom treatment with complete dentures was planned were recruited. The cement was implanted in one defect per subject with a presurgical probing depth of at least 7 mm and a radiographic bone defect of 4 mm or more. Patients were seen every 2 weeks for periodontal maintenance. At 6 months, clinical measurements were repeated and the tooth was removed en bloc for histologic processing. Results demonstrated that all defects resulted in probing depth reduction and, at three of the four defects, in clinical attachment level gain. However, no site showed periodontal regeneration. There was no new bone formation. New cementum and connective tissue were limited to 0.2 mm or less. Large deposits of the bone cement were noted encapsulated in connective tissue.
Bianchi, Andrea E; Bassetti, Achille
2009-04-01
The aim of this paper was to describe a new surgical technique designed to preserve interdental tissue in guided tissue regeneration. This procedure was created to specifically regenerate wide intrabony defects in the esthetic zone. Fourteen subjects with an intraosseous defect in the maxillary incisor region took part in this clinical study. The defects were treated with bioresorbable membranes in combination with a bovine bone mineral graft. At baseline and at 12 months after surgery, the following clinical parameters were measured: full-mouth plaque scores, full-mouth bleeding scores, probing pocket depths, clinical attachment levels, and gingival recession. A significant gain in clinical attachment level (4.57 +/- 0.65 mm) and a reduction in probing depths (5.14 +/- 0.95 mm) were reported 12 months after surgery. The surgical technique allowed complete flap closure in every treated site, resulting in significant improvement of the clinical parameters; thus, it appeared especially appropriate for the treatment of wide defects in the esthetic zone.
NASA Astrophysics Data System (ADS)
Zhang, Yunyao; Zhu, Jingping; Cui, Weiwen; Nie, Wei; Li, Jie; Xu, Zhenghong
2015-03-01
We investigated the performance of endoscopic diffuse optical spectroscopy probes with circular or linear fiber arrangements for tubular organ cancer detection. Probe performance was measured by penetration depth. A Monte Carlo model was employed to simulate light transport in the hollow cylinder that both emits and receives light from the inner boundary of the sample. The influence of fiber configurations and tissue optical properties on penetration depth was simulated. The results show that under the same condition, probes with circular fiber arrangement penetrate deeper than probes with linear fiber arrangement, and the difference between the two probes' penetration depth decreases with an increase in the 'distance between source and detector (SD)' and the radius of the probe. Other results show that the penetration depths and their differences both decrease with an increase in the absorption coefficient and the reduced scattering coefficient but remain constant with changes in the anisotropy factor. Moreover, the penetration depth was more affected by the absorption coefficient than the reduced scattering coefficient. It turns out that in NIR band, probes with linear fiber arrangements are more appropriate for diagnosing superficial cancers, whereas probes with circular fiber arrangements should be chosen for diagnosing adenocarcinoma. But in UV-VIS band, the two probe configurations exhibit nearly the same. These results are useful in guiding endoscopic diffuse optical spectroscopy-based diagnosis for esophageal, cervical, colorectal and other cancers.
Effect of Probe Tube Insertion Depth on Spectral Measures of Speech
Caldwell, Marc; Souza, Pamela E.; Tremblay, Kelly L.
2006-01-01
This study investigated how depth variations in the tip of the probe tube affected spectral measures of speech recorded in the external ear canal. Consonant-vowel nonsense syllables were recorded with a probe tube microphone system in 10 adult participants with normal middle ear function. Recordings were made with the probe tube tip placed 1 mm, 5 mm, and 10 mm beyond the medial tip of a custom earmold. The effect of probe depth was evaluated on spectral levels (one-third octave and one-twelfth octave band). Extending the probe tube 10 mm past the medial tip of the earmold gave the most accurate results, with relatively lower sound levels for either the 1-mm or 5-mm insertion depth. In general, the effect of insertion depth was minimal at frequencies below 3 to 4 kHz, although this varied with the specific phoneme and the width of the analysis bands. The authors found no significant difference between 1- and 5-mm insertion depths, suggesting that as long as the tip of the probe tube is sufficiently close to the tympanic membrane to capture the highest frequency of interest, it makes little difference if it is less than 5 mm beyond the earmold tip. PMID:16959735
Upper Ocean Characteristics in the Tropical Indian Ocean from AXBT and AXCTD Measurements
2012-03-01
processors. 30 As a last resort, we contacted the vendor of the AXCTD probes, Lockheed Martin Sippican, for data reduction support. AXCTD (.wav) files...that were unsuccessfully recovered with the previously discussed methods were provided to Lockheed Martin technical team who used the MK21 signal...data from the top subjectively. We requested both the original and the depth corrected .dta files from Lockheed Martin to evaluate their bias
Mathew, Jayan Jacob; Ambooken, Majo; Kachappilly, Arun Jose; PK, Ajithkumar; Johny, Thomas; VK, Linith; Samuel, Anju
2015-01-01
Introduction Adjunctive use of professional subgingival irrigation with scaling and root planing (SRP) has been found to be beneficial in eradicating the residual microorganisms in the pocket. Objective To evaluate the effect of ozonized water subgingival irrigation on microbiologic parameters and clinical parameters namely Gingival index, probing pocket depth, and clinical attachment level. Materials and Methods Thirty chronic periodontitis patients with probing pocket depth ≥6mm on at least one tooth on contra lateral sides of opposite arches were included in the study. The test sites were subjected to ozonized water subgingival irrigation with subgingival irrigation device fitted with a modified subgingival tip. Control sites were subjected to scaling and root planing only. The following clinical parameters were recorded initially and after 4 weeks at the test sites and control sites. Plaque Index, Gingival Index, probing pocket depth, clinical attachment level. Microbiologic sampling was done for the test at the baseline, after scaling, immediately after ozonized water subgingival irrigation and after 4 weeks. In control sites microbiologic sampling was done at the baseline, after scaling and after 4 weeks. The following observations were made after 4 weeks. The results were statistically analysed using independent t-test and paired t-test. Result Test sites showed a greater reduction in pocket depth and gain in clinical attachment compared to control sites. The total anaerobic counts were significantly reduced by ozonized water subgingival irrigation along with SRP compared to SRP alone. Conclusion Ozonized water subgingival irrigation can improve the clinical and microbiological parameters in patients with chronic periodontitis when used as an adjunct to scaling and root planing. PMID:26436042
Liu, H; Puangmali, P; Zbyszewski, D; Elhage, O; Dasgupta, P; Dai, J S; Seneviratne, L; Althoefer, K
2010-01-01
This paper presents a novel wheeled probe for the purpose of aiding a surgeon in soft tissue abnormality identification during minimally invasive surgery (MIS), compensating the loss of haptic feedback commonly associated with MIS. Initially, a prototype for validating the concept was developed. The wheeled probe consists of an indentation depth sensor employing an optic fibre sensing scheme and a force/torque sensor. The two sensors work in unison, allowing the wheeled probe to measure the tool-tissue interaction force and the rolling indentation depth concurrently. The indentation depth sensor was developed and initially tested on a homogenous silicone phantom representing a good model for a soft tissue organ; the results show that the sensor can accurately measure the indentation depths occurring while performing rolling indentation, and has good repeatability. To validate the ability of the wheeled probe to identify abnormalities located in the tissue, the device was tested on a silicone phantom containing embedded hard nodules. The experimental data demonstrate that recording the tissue reaction force as well as rolling indentation depth signals during rolling indentation, the wheeled probe can rapidly identify the distribution of tissue stiffness and cause the embedded hard nodules to be accurately located.
Sehdev, Bhumika; Bhongade, Manohar Laxmanrao; Ganji, Kiran Kumar
2016-01-01
Background: The combination of biomaterials, bone graft substitutes along with guided tissue regeneration (GTR) has been shown to be an effective modality of periodontal regenerative therapy for infrabony defects. Therefore, the present randomized controlled clinical study was undertaken to evaluate the effectiveness of hyaluronic acid (HA) in combination with bioresorbable membrane for the treatment of human infrabony defects. Materials and Methods: Twenty four infrabony defects in 20 systemically healthy patients were randomly assigned to test (HA in combination with bioresorbable membrane) and control (bioresorbable membrane alone) treatment groups. Probing pocket depth (PPD), relative attachment level, and relative gingival margin level were measured with a computerized Florida disc probe at baseline and at 6 months follow-up. Radiographic measurements were also evaluated at baseline and at 6 months of postsurgery. Results: At 6 months, the mean reduction in PPD in test group and control group was 4.52 mm and 2.97 mm, respectively. Significantly higher clinical attachment level with a gain of 2.20 mm was found in the test group as compared to control group. In addition, statistically significant greater reduction of radiographic defect depth was observed in the test group. Conclusion: Regenerative approach using hyaloss in combination with GTR for the treatment of human infrabony defects resulted in a significant added benefit in terms of CAL gains, PPD reductions and radiographic defect fill, as well as LBG, compared to the GTR alone. PMID:27041838
Aging and the depth of binocular rivalry suppression.
Norman, J Farley; Norman, Hideko F; Pattison, Kristina; Taylor, M Jett; Goforth, Katherine E
2007-09-01
Two experiments were designed to examine the effect of aging on the strength of binocular rivalry suppression. To produce rivalry, orthogonally oriented sine-wave luminance gratings were presented dichoptically. The observers were then required either to discriminate the spatial location of a probe spot presented to the dominant or suppressed eye's view or to detect the presence or absence of the probe. The observers in the younger and older age groups exhibited typical rivalry suppression for both tasks (i.e., the probe was more difficult to detect or discriminate when presented to the suppressed eye), but the magnitude of the suppression was significantly larger in the older observers. This increased suppression that accompanies aging can be explained by a reduction in the inhibition produced by the binocular matching circuitry of S. R. Lehky and R. Blake's (1991) model. (PsycINFO Database Record (c) 2007 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Heikoop, J. M.; Newman, B. D.; Hudak, M.; Gard, M.; Altmann, G.; Throckmorton, H.; Wilson, C. J.
2013-12-01
Climate driven warming and degradation of permafrost may lead to changes in the hydrology of low gradient regions like the North Slope of Alaska. Hydrologic changes will affect the saturation and redox state of soils in drained thaw lake basins (DTLBs), interlake areas, and associated drainages. These changes are being investigated at the Barrow Environmental Observatory (BEO) and surroundings as part of the Next Generation Ecosystem Experiment - Arctic project. As a complement to traditional redox and aqueous chemistry measurements, the use of indicator of reduction in soils (IRIS) probes is being assessed as a simple and cost-effective way to monitor redox changes. The probes consist of PVC sheets coated with a ferrihydrite paint. Under reducing conditions iron on these probes will partially dissolve. The amount of dissolution can be quantified by image analysis and related in a semi-quantitative fashion to redox conditions in the soils. IRIS probes have been successfully utilized in numerous temperate settings to demonstrate, for example, the presence of reducing soils for wetlands delineation. Test probes were installed in saturated soils for 48 hours in July, 2013. After 48 hours, minor reductive dissolution of ferrihydrite was observed. No sulfide precipitation was noted. As such, probes were installed in quadruplicate at 14 locations representing primarily outlet drainages from different-aged DTLBs and interlake areas. In each case, the probes were installed to refusal at the frost table within the active layer overlying the permafrost. IRIS probes were deployed adjacent to arrays of rhizon samplers used for soil pore water sampling so that time-integrated IRIS probe results can be compared to chemical results (a snapshot in time) obtained at the beginning and end of the monitoring period (probes will be extracted in September). Image analysis will employ LANL's GENIE technology. Field measurements of ferrous iron in water samples showed significant redox variation both between locations and with depth at each location. Values were lowest in surface waters (as low as zero mg/L) and were generally higher in soil pore water with values up to approximately 7 mg/L. Correlations between percentage iron removal from the IRIS probes and ferrous iron and other redox sensitive species will be presented. If correlations are significant, redox couples (ammonia/nitrate, Fe(II)/Fe(III), sulfide/sulfate) will be used to estimate Eh and to develop an empirical relationship for the use of IRIS probes in the BEO and surrounding environs.
Clinical tests of an ultrasonic periodontal probe
NASA Astrophysics Data System (ADS)
Hinders, Mark K.; Lynch, John E.; McCombs, Gayle B.
2002-05-01
A new ultrasonic periodontal probe has been developed that offers the potential for earlier detection of periodontal disease activity, non-invasive diagnosis, and greater reliability of measurement. A comparison study of the ultrasonic probe to both a manual probe, and a controlled-force probe was conducted to evaluate its clinical effectiveness. Twelve patients enrolled into this study. Two half-month examinations were conducted on each patient, scheduled one hour apart. A one-way analysis of variance was performed to compare the results for the three sets of probing depth measurements, followed by a repeated measures analysis to assess the reproducibility of the different probing techniques. These preliminary findings indicate that manual and ultrasonic probing measure different features of the pocket. Therefore, it is not obvious how the two depth measurements correspond to each other. However, both methods exhibited a similar tendency toward increasing pocket depths as Gingival Index scores increased. Based on the small sample size, further studies need to be conducted using a larger population of patients exhibiting a wider range of disease activity. In addition, studies that allow histological examination of the pocket after probing will help further evaluate the clinical effectiveness the ultrasonic probe. Future studies will also aid in the development of more effective automated feature recognition algorithms that convert the ultrasonic echoes into pocket depth readings.
Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination.
Meaney, Paul M; Gregory, Andrew P; Seppälä, Jan; Lahtinen, Tapani
2016-03-01
We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50 Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on probe diameter but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50 Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies.
Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination
Meaney, Paul M.; Gregory, Andrew P.; Seppälä, Jan; Lahtinen, Tapani
2016-01-01
We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50 Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on probe diameter but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50 Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies. PMID:27346890
Dodge, Austin; Garcia, Jeffrey; Luepke, Paul; Lai, Yu-Lin; Kassab, Moawia; Lin, Guo-Hao
2018-04-01
The aim of this systematic review was to compare the root-coverage outcomes of using a partially exposed connective tissue graft (CTG) technique with a fully covered CTG technique for root coverage. An electronic search up to February 28 th , 2017, was performed to identify human clinical studies with data comparing outcomes of root coverage using CTG, with and without a partially exposed graft. Five clinical studies were selected for inclusion in this review. For each study, the gain of keratinized gingiva, reduction of recession depth, number of surgical sites achieving complete root coverage, percentage of root coverage, gain of tissue thickness, and changes of probing depth and clinical attachment level were recorded. Meta-analysis for the comparison of complete root coverage between the two techniques presented no statistically significant differences. A statistically significant gain of keratinized tissue in favor of the sites with an exposed CTG and a tendency of greater reduction in recession depth were seen at the sites with a fully covered CTG. Based on the results, the use of a partially exposed CTG in root-coverage procedures could achieve greater gain in keratinized gingiva, while a fully covered CTG might be indicated for procedures aiming to reduce recession depth. © 2018 Eur J Oral Sci.
Du, Mingde; Xu, Xianchen; Yang, Long; Guo, Yichuan; Guan, Shouliang; Shi, Jidong; Wang, Jinfen; Fang, Ying
2018-05-15
Subdural surface and penetrating depth probes are widely applied to record neural activities from the cortical surface and intracortical locations of the brain, respectively. Simultaneous surface and depth neural activity recording is essential to understand the linkage between the two modalities. Here, we develop flexible dual-modality neural probes based on graphene transistors. The neural probes exhibit stable electrical performance even under 90° bending because of the excellent mechanical properties of graphene, and thus allow multi-site recording from the subdural surface of rat cortex. In addition, finite element analysis was carried out to investigate the mechanical interactions between probe and cortex tissue during intracortical implantation. Based on the simulation results, a sharp tip angle of π/6 was chosen to facilitate tissue penetration of the neural probes. Accordingly, the graphene transistor-based dual-modality neural probes have been successfully applied for simultaneous surface and depth recording of epileptiform activity of rat brain in vivo. Our results show that graphene transistor-based dual-modality neural probes can serve as a facile and versatile tool to study tempo-spatial patterns of neural activities. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Peng, Kaung-Jay; Wu, Chun-Lung; Lin, Yung-Hsiang; Wang, Hwai-Yung; Cheng, Chih-Hsien; Chi, Yu-Chieh; Lin, Gong-Ru
2018-01-01
Using the evanescent-wave saturation effect of hydrogen-free low-temperature synthesized few-layer graphene covered on the cladding region of a side-polished single-mode fiber, a blue pump/infrared probe-based all-optical switch is demonstrated with specific wavelength-dependent probe modulation efficiency. Under the illumination of a blue laser diode at 405 nm, the few-layer graphene exhibits cross-gain modulation at different wavelengths covering the C- and L-bands. At a probe power of 0.5 mW, the L-band switching throughput power variant of 16 μW results in a probe modulation depth of 3.2%. Blue shifting the probe wavelength from 1580 to 1520 nm further enlarges the switching throughput power variant to 24 mW and enhances the probe modulation depth to 5%. Enlarging the probe power from 0.5 to 1 mW further enlarges the switching throughput power variant from 25 to 58 μW to promote its probe modulation depth of up to 5.8% at 1520 nm. In contrast, the probe modulation depth degrades from 5.1% to 1.2% as the pumping power reduces from 85 to 24 mW, which is attributed to the saturable absorption of the few-layer graphene-based evanescent-wave absorber. The modulation depth at wavelength of 1550 nm under a probe power of 1 mW increases from 1.2% to 5.1%, as more carriers can be excited when increasing the blue laser power from 24 to 85 mW, whereas it decreases from 5.1% to 3.3% by increasing the input probe power from 1 to 2 mW to show an easier saturated condition at longer wavelength.
Sap flow characteristics of neotropical mangroves in flooded and drained soils
Krauss, Ken W.; Young, P. Joy; Chambers, Jim L.; Doyle, Thomas W.; Twilley, Robert R.
2007-01-01
Effects of flooding on water transport in mangroves have previously been investigated in a few studies, most of which were conducted on seedlings in controlled settings. In this study, we used heat-dissipation sap probes to determine if sap flow (Js) attenuates with radial depth into the xylem of mature trees of three south Florida mangrove species growing in Rookery Bay. This was accomplished by inserting sap probes at multiple depths and monitoring diurnal flow. For most species and diameter size class combinations tested, Js decreased dramatically beyond a radial depth of 2 or 4 cm, with little sap flow beyond a depth of 6 cm. Mean Js was reduced on average by 20% in Avicennia germinans (L.) Stearn, Laguncularia racemosa (L.) Gaertn. f. and Rhizophora mangle L. trees when soils were flooded. Species differences were highly significant, with L. racemosahaving the greatest midday Js of about 26g H2O H2O m−2s−1 at a radial depth of 2 cm compared with a mean for the other two species of about 15 g H2O m−2s−1. Sap flow at a depth of 2 cm in mangroves was commensurate with rates reported for other forested wetland tree species. We conclude that: (1) early spring flooding of basin mangrove forests causes reductions in sap flow in mature mangrove trees; (2) the sharp attenuations in Js along the radial profile have implications for understanding whole-tree water use strategies by mangrove forests; and (3) regardless of flood state, individual mangrove tree water use follows leaf-level mechanisms in being conservative.
Hassan, Khalid S; Marei, Hesham F; Alagl, Adel S
2012-04-01
This study was designed to evaluate the use of xenograft plus a membrane as grafting material for periodontal osseous defects distal to the mandibular second molar compared with nongrafted extraction sites after removal of impacted mandibular third molars. We performed a single-blind, randomized, controlled clinical trial, and the sample comprised of subjects at high risk for the development of periodontal osseous defects distal to the second molar after third molar extraction (aged 30-35 years), pre-existing osseous defects distal to the second molar, and horizontal third molar impaction. The predictor variable was the treatment status of the second molar osseous defects. The third molar extraction sites were grafted with an anorganic xenograft plus a membrane. The other sites received a full-thickness flap and extraction of the third molar without placement of the grafting materials. The outcome variables were the change in gingival index, pocket probing depth, and clinical attachment level on the distobuccal aspect of the second molar preoperatively and at 3, 6, 9, and 12 months after surgery. Data were statistically analyzed by multivariate analysis of variance, and the statistical significance was set at P < .05. The study was composed of 28 sites that were selected by use of a split-mouth design for each patient, and this was randomly determined through a biased coin randomization. Twelve months after third molar removal, there was a statistically significant gain in the clinical attachment level and a reduction in the probing pocket depth in the grafted sites compared with the nongrafted sites (P < .001). Moreover, there was a significant difference in the alveolar bone height during the monitoring periods for the grafted sites compared with the nongrafted sites (P < .001). Grafting of osseous defects distal to mandibular second molars with an anorganic xenograft plus a membrane predictably resulted in a significant reduction in the probing pocket depth, clinical attachment level gain, and bone fill, which suggests that grafting the extraction sites with an anorganic xenograft plus a membrane could prevent periodontal disease in the future. Published by Elsevier Inc.
Management of gingival recession with acellular dermal matrix graft: A clinical study
Balaji, V. R.; Ramakrishnan, T.; Manikandan, D.; Lambodharan, R.; Karthikeyan, B.; Niazi, Thanvir Mohammed; Ulaganathan, G.
2016-01-01
Aims and Objectives: Obtaining root coverage has become an important part of periodontal therapy. The aims of this studyare to evaluate the clinical efficacy of acellular dermal matrix graft in the coverage of denuded roots and also to examine the change in the width of keratinized gingiva. Materials and Methods: A total of 20 sites with more than or equal to 2 mm of recession depth were taken into the study, for treatment with acellular dermal matrix graft. The clinical parameters such as recession depth, recession width, width of keratinized gingiva, probing pocket depth (PD), and clinical attachment level (CAL) were measured at the baseline, 8th week, and at the end of the study (16th week). The defects were treated with a coronally positioned pedicle graft combined with acellular dermal matrix graft. Results: Out of 20 sites treated with acellular dermal matrix graft, seven sites showed complete root coverage (100%), and the mean root coverage obtained was 73.39%. There was a statistically significant reduction in recession depth, recession width, and probing PD. There was also a statistically significant increase in width of keratinized gingiva and also gain in CAL. The postoperative results were both clinically and statistically significant (P < 0.0001). Conclusion: The results of this study were esthetically acceptable to the patients and clinically acceptable in all cases. From this study, it may be concluded that acellular dermal matrix graft is an excellent substitute for autogenous graft in coverage of denuded roots. PMID:27829749
A numerically optimized active shield for improved TMS targeting
Hernandez-Garcia, Luis; Hall, Timothy; Gomez, Luis; Michielssen, Eric
2010-01-01
Transcranial magnetic stimulation (TMS) devices suffer of poor targeting and penetration depth. A new approach to designing TMS coils is introduced in order to improve the focus of the stimulation region through the use of actively shielded probes. Iterative optimization techniques were used to design different active shielding coils for TMS probes. The new approach aims to increase the amount of energy deposited in a thin cylindrical region below the probe relative to the energy deposited elsewhere in the region (“sharpness”), while simultaneously increase the induced electric field deep in the target region relative to the surface (“penetration”). After convergence, the resulting designs showed that there is a clear tradeoff between sharpness and penetration that can be controlled by the choice of a tuning parameter. The resulting designs were tested on a realistic human head conductivity model, taking the contribution from surface charges into account. The design of choice reduced penetration depths by 16.7%. The activated surface area was reduced by 24.1 % and the volume of the activation was reduced from 42.6% by the shield. Restoring the lost penetration could be achieved by increasing the total power to the coil by 16.3%, but in that case, the stimulated volume reduction was only 13.1% and there was a slight increase in the stimulated surface area (2.9 %) PMID:20965451
A numerically optimized active shield for improved transcranial magnetic stimulation targeting.
Hernandez-Garcia, Luis; Hall, Timothy; Gomez, Luis; Michielssen, Eric
2010-10-01
Transcranial magnetic stimulation (TMS) devices suffer of poor targeting and penetration depth. A new approach to designing TMS coils is introduced in order to improve the focus of the stimulation region through the use of actively shielded probes. Iterative optimization techniques were used to design different active shielding coils for TMS probes. The new approach aims to increase the amount of energy deposited in a thin cylindrical region below the probe relative to the energy deposited elsewhere in the region ("sharpness"), whereas, simultaneously increase the induced electric field deep in the target region relative to the surface ("penetration"). After convergence, the resulting designs showed that there is a clear tradeoff between sharpness and penetration that can be controlled by the choice of a tuning parameter. The resulting designs were tested on a realistic human head conductivity model, taking the contribution from surface charges into account. The design of choice reduced penetration depths by 16.7%. The activated surface area was reduced by 24.1% and the volume of the activation was reduced from 42.6% by the shield. Restoring the lost penetration could be achieved by increasing the total power to the coil by 16.3%, but in that case, the stimulated volume reduction was only 13.1% and there was a slight increase in the stimulated surface area (2.9%). Copyright © 2010 Elsevier Inc. All rights reserved.
Impact of Yoga on Periodontal Disease and Stress Management.
Sudhanshu, Archika; Sharma, Urvi; Vadiraja, H S; Rana, Rakesh Kumar; Singhal, Richa
2017-01-01
Yoga is considered to be one of the most important, effective, and valuable tools available for man to overcome various physical and psychological problems. Stress contributes significantly to the pathogenesis of periodontal diseases; hence, it becomes important to reduce the level of stress for prevention and management of diseases. The present study was aimed: (1) To understand and analyze the possibilities of employing yogic practices in the treatment of periodontal disease along with conventional dental therapy, (2) to understand the effect of stress on periodontal treatment outcome, (3) to evaluate the efficacy of yoga in the management of periodontal disease with reference to stress. An outpatient department-based parallel group randomized study was performed with standard treatment for periodontal disease yoga therapy as Group II and only standard treatment as Group I. Periodontal health status was recorded using indices of modified plaque index (PI), bleeding on probing (BOP), probing depth, and clinical attachment loss (CAL). The Cohen's perceived stress questionnaire was also used to determine stress severity. The yogic intervention consists of lectures and practical sessions on asanas, pranayama, kriyas, and meditation. Repeated measure analysis of variance revealed a significant difference ( P < 0.001) in all the outcome variables with respect to time in both groups. It was observed that mean PI score reduced by 1.35 in Group II as compared to 0.54 in Group I, mean probing pocket depth reduced by 1.60 in Group II as compared to only 0.68 in Group I, and mean CAL score reduced by 1.60 in Group II as compared to 0.68 in Group I. Similarly, Cohen's perceived stress scale score also reduced by 18.76 points in Group II as compared to only 2.58 points in Group I, BOP also shows better improvement in Group II with a reduction of 0.68 as compared to reduction of only 0.08 in Group I. The results obtained ascertained the role of yoga in stress reduction in periodontal disease. Although yoga does not play a direct role in improving periodontal disease, it accelerates the treatment outcomes by combating the stress which is a major factor affecting the treatment of periodontal disease.
NASA Astrophysics Data System (ADS)
Winebrenner, D. P.; Elam, W. T.; Carpenter, M.; Kintner, P., III
2014-12-01
More numerous observations within and beneath ice sheets are needed to address a broad variety of important questions concerning ice sheets and climate. However, emplacement of instruments continues to be constrained by logistical burdens, especially in cold ice a kilometer or more thick. Electrically powered thermal melt probes are inherently logistically light and efficient, especially for reaching greater depths in colder ice. They therefore offer a means of addressing current measurement problems, but have been limited historically by a lack of technology for reliable operation at the necessary voltages and powers. Here we report field tests in Greenland of two new melt probes. We operated one probe at 2.2 kilowatts (kW) and 1050 volts (V), achieving a depth of 400 m in the ice in ~ 120 hours, without electrical failure. That depth is the second greatest achieved thus far with a thermal melt probe, exceeded only by one deployment to 1005 m in Greenland in 1968, which ended in an electrical failure. Our test run took place in two intervals separated by a year, with the probe frozen at 65 m depth during the interim, after which we re-established communication, unfroze the probe, and proceeded to the greater depth. During the second field test we operated a higher-power probe, initially at 2.5 kW and 1500 V and progressing to 4.5 kW and 2000 V. Initial data indicate that this probe achieved a descent rate of 8 m/hr, which if correct would be the fastest rate yet achieved for such probes. Moreover, we observed maintenance of vertical probe travel using pendulum steering throughout both tests, as well as autonomous descent without operator-intervention after launch. The latter suggests potential for crews of 1-2 to operate several melt probes concurrently. However, the higher power probe did suffer electrical failure of a heating element after 7 hours of operation at 2000 V (24 hours after the start of the test), contrary to expectations based on laboratory component and system testing. We are therefore revising the probe heaters using a newer but more development-intensive technology. With probe systems now validated in our tests, this will result in a reliable means to emplace instruments for studies of subglacial hydrology, ice dynamics, and possible subglacial ecologies.
Periodontal status among adolescents in Georgia. A pathfinder study.
Levin, Liran; Margvelashvili, Vladimer; Bilder, Leon; Kalandadze, Manana; Tsintsadze, Nino; Machtei, Eli E
2013-01-01
Objectives. The aim of the present pathfinder study was to screen and map the periodontal status of Georgian population in accordance with the guidelines of the World Health Organization for population based surveys. Methods. During 2012, a pathfinder study was conducted to collect this data. For the periodontal portion of the study, 15-year-old school children were examined in the capital city of Tbilisi as well as in two other large cities and 4 smaller villages. All participants were examined by a trained dental team in a classroom using a dental mirror and a periodontal probe. Periodontal examination included plaque scores, calculus scores, probing depth measurements and bleeding on probing. These measurements were recorded for the Ramfjord index teeth. Results. A total of 397 15-year-old participants were examined in this pathfinder study. There were 240 females (60.45%) and 157 males (39.55%). Of the total participants 196 (49.37%) were urban adolescents while 201 (50.63%) were from rural communities. Mean probing depth was 3.34 ± 0.57 mm with a range of 1 to 10 mm; a relatively high proportion (34.26%) of these subjects presented with at least one site with pockets of 5 mm or deeper. Males presented with greater plaque, calculus and probing depths than females. When urban and rural populations were compared, urban participants presented with more plaque, probing depths and bleeding on probing. Greater pocket depths were found to be related to the presence of plaque calculus and bleeding on probing. Conclusions. Overall, rather high incidences of periodontal pockets ≥ 5 mm were detected in this population. This data should serve to prepare further more detailed epidemiological studies that will serve to plan and implement prevent and treat strategies for periodontal diseases in Georgia and also help make manpower decisions.
Pippi, Roberto
2013-01-01
The primary aim of the present study was to validate the effectiveness of a personalized device able to guide periodontal probing in evaluation of second molar periodontal healing after adjacent third molar surgical extraction. Secondarily, the study analyzed if any patient and tooth related factors affected the second molar periodontal healing as well as if they were able to affect the periodontal probing depth performed with or without the personalized device. Thirty-five lower second molars were evaluated after extraction of the adjacent third molar. Pre-operative as well as 3 and 12 month post-operative probing depths of the distal surface of the second molar were evaluated. All measurements were taken by two different methods: standard two-point and four-point probing using a personalized onlay-type guide. Periapical radiographs were also evaluated. The Pearson product moment and the general linear model with backward stepwise procedure were used for inferential statistics. The mean 12-month post-operative probing depth/mean pre-operative probing depth ratio obtained with the guided probing method showed a highly significant effect on the 12-month radiographic post-operative/pre-operative radiographic measure ratio. None of the examined patient- or tooth-related factors showed a significant effect on pre-operative/12-month post-operative radiographic measure ratio. The use of the proposed personalized device seems to provide a more reliable estimate of second molar periodontal healing after adjacent third molar surgical extraction. No patient-or tooth-related factors seem to be able to affect either second molar periodontal healing or probing depth measures obtained with or without the personalized device in individuals younger than 25 years old. It can be therefore recommended that lower third molar surgical extraction be performed in young adults.
Surgical management of cosmetic mucogingival defects.
Dym, Harry; Tagliareni, Jonathan M
2012-01-01
Mucogingival conditions are deviations from the normal anatomic relationship between the gingival margin and the mucogingival junction. Mucogingival surgery is plastic surgery designed to correct defects in the gingiva surrounding the teeth. Common mucogingival conditions are recession, absence, or reduction of keratinized tissue, and probing depths extending beyond the mucogingival junction. Surgical techniques used to augment cosmetic mucogingival defects include the free gingival autograft, the subepithelial connective tissue graft, rotational flaps, lateral sliding flaps, coronally repositioned flaps, and the use of acellular dermal matrix grafts. Copyright © 2012 Elsevier Inc. All rights reserved.
Modular 3D-Printed Soil Gas Probes
NASA Astrophysics Data System (ADS)
Good, S. P.; Selker, J. S.; Al-Qqaili, F.; Lopez, M.; Kahel, L.
2016-12-01
ABSTRACT: Extraction of soil gas is required for a variety of applications in earth sciences and environmental engineering. However, commercially available probes can be costly and are typically limited to a single depth. Here, we present the open-source design and lab testing of a soil gas probe with modular capabilities that allow for the vertical stacking of gas extraction points at different depths in the soil column. The probe modules consist of a 3D printed spacer unit and hydrophobic gas permeable membrane made of high density Polyethylene with pore sizes 20-40 microns. Each of the modular spacer units contain both a gas extraction line and gas input line for the dilution of soil gases if needed. These 2-inch diameter probes can be installed in the field quickly with a hand auger and returned to at any frequency to extract soil gas from desired soil depths. The probes are tested through extraction of soil pore water vapors with distinct stable isotope ratios.
Kwon, Eun-Young; Cho, Yunjung; Lee, Ju-Youn; Kim, Sung-Jo
2013-01-01
Purpose The aim of this study was to identify a role for endodontic intervention in enhancing the regenerative potential of the periodontal ligament when combined with periodontal treatment in seriously involved teeth with a secondary endodontic component. Methods Patients who exhibited radiolucency extending to the periapical region, abnormal electric pulp testing values, and deep probing depth derived from primary periodontal disease with secondary endodontic involvement were included. Intentional root canal treatment was applied to those teeth in which the apical lesions were presumed to communicate with those of the periodontal lesion of the teeth that remained vital. In all three selected cases, regenerative periodontal therapy incorporating either bone graft or guided tissue regeneration was instituted 3 months after the endodontic intervention. Results Remarkable enhancement in radiographic density was noticeable around the affected teeth as evidenced by changes in radiopacity. There was a significant reduction in the probing pocket depth and gain in the clinical attachment level. Chewing discomfort gradually disappeared from the commencement of the combined treatment. Conclusions An intentional endodontic intervention may be a worthwhile approach for the sophisticated management of teeth suffering from serious attachment loss and alveolar bone destruction with concomitant secondary endodontic involvement. PMID:23837128
Dudley, Nicholas J; Gibson, Nicholas M
2017-02-01
The aim of this study was to test the hypothesis that grey levels are a suitable alternative measure of sensitivity in ultrasound imaging quality assurance, as there are several caveats in the use of penetration depth. In a primary cohort of nine probes, where measurements had been made for 6 to 34 mo, both penetration depth and mean grey level fell below tolerance for six probes; both penetration depth and mean grey level remained within tolerance for three probes. In a secondary cohort where a measurement programme had been in place for a shorter period, grey level and/or penetration depth fell below tolerance in 15 of 66 probes; the sensitivity and specificity of at least 10% loss of grey level in predicting >5% loss in penetration depth were 91% and 93%, respectively. A loss of grey level accompanies a loss of penetration and provides a suitable alternative measure of sensitivity. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kono, Naoyuki; Miki, Masahiro; Nakamura, Motoyuki; Ehara, Kazuya
2007-03-01
Phased array techniques are capable of the sensitive detection and precise sizing of flaws or cracks in components of nuclear power plants by using arbitrary focal beams with various depths, positions and angles. Aquantitative investigation of these focal beams is essential for the optimization of array probes, especially for austenitic weld inspection, in order to improve the detectability, sizing accuracy, and signal-to-noise ratio using these beams. In the present work, focal beams generated by phased array probes are calculated based on the Fresnel-Kirchhoff diffraction integral (FKDI) method, and an approximation formula between the actual focal depth and optical focal depth is proposed as an extension of the theory for conventional spherically focusing probes. The validity of the approximation formula for the array probes is confirmed by a comparison with simulation data using the FKDI method, and the experimental data.
21 CFR 872.1870 - Sulfide detection device.
Code of Federal Regulations, 2012 CFR
2012-04-01
.... A sulfide detection device is a device consisting of an AC-powered control unit, probe handle, probe... periodontal pocket probing depths, detect the presence or absence of bleeding on probing, and detect the...
21 CFR 872.1870 - Sulfide detection device.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... A sulfide detection device is a device consisting of an AC-powered control unit, probe handle, probe... periodontal pocket probing depths, detect the presence or absence of bleeding on probing, and detect the...
21 CFR 872.1870 - Sulfide detection device.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... A sulfide detection device is a device consisting of an AC-powered control unit, probe handle, probe... periodontal pocket probing depths, detect the presence or absence of bleeding on probing, and detect the...
21 CFR 872.1870 - Sulfide detection device.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... A sulfide detection device is a device consisting of an AC-powered control unit, probe handle, probe... periodontal pocket probing depths, detect the presence or absence of bleeding on probing, and detect the...
Pulsed Eddy Current Probe Design Based on Transient Circuit Analysis
NASA Astrophysics Data System (ADS)
Cadeau, Trevor J.; Krause, Thomas W.
2009-03-01
Probe design parameters affecting depth of penetration of pulsed eddy currents in multi-layer aluminum 2024-T3 were examined. Several probe designs were evaluated for their ability to detect a discontinuity at the bottom of a stack of aluminum plates. The reflection type probes, consisting of pick-up coil and encircling drive coil, were characterized based on their transient response to a square pulse excitation. Probes with longer fundamental time constants, equivalent to a lower driving frequency, generated greater depth of penetration. However, additional factors such as inductive and resistive load, and excessive coil heating were also factors that limited signal-to-noise response with increasing layer thickness.
Elgendy, Enas Ahmed; Abo Shady, Tamer Elamer
2015-01-01
Background: Nano-sized ceramics may represent a promising class of bone graft substitutes due to their improved osseointegrative properties. Nanocrystalline hydroxyapatite (NcHA) binds to bone and stimulate bone healing by stimulation of osteoblast activity. Platelet-rich fibrin (PRF), an intimate assembly of cytokines, glycan chains, and structural glycoproteins enmeshed within a slowly polymerized fibrin network, has the potential to accelerate soft and hard tissue healing. The present study aims to explore the clinical and radiographical outcome of NcHA bone graft with or without PRF, in the treatment of intrabony periodontal defects. Materials and Methods: In a split-mouth study design, 20 patients having two almost identical intrabony defects with clinical probing depth of at least 6 mm were selected for the study. Selected sites were randomly divided into two groups. In Group I, mucoperiosteal flap elevation followed by the placement of NcHA was done. In Group II, mucoperiosteal flap elevation, followed by the placement of NcHA with PRF was done. Clinical and radiographic parameters were recorded at baseline and at 6-month postoperatively. Results: Both treatment groups showed a significant probing pocket depth (PPD) reduction, clinical attachment gain, increase bone density 6-month after surgery compared with baseline. However, there was a significantly greater PPD reduction and clinical attachment gain when PRF was added to NcHA. Conclusion: The NcHA bone graft in combination with PRF demonstrated clinical advantages beyond that achieved by the NcHA alone. PMID:25810595
Gholami, Gholam Ali; Saberi, Arezoo; Kadkhodazadeh, Mahdi; Amid, Reza; Karami, Daryoosh
2013-01-01
Background: Different techniques have been proposed for the treatment of gingival recession. The majority of current procedures use autogenous soft-tissue grafts, which are associated with morbidity at the donor sites. Acellular dermal matrix (ADM) Alloderm is an alternative donor material presented to reduce related morbidity and provide more volume of the donor tissue. This study aimed to evaluate the effectiveness of an ADM allograft for root coverage and to compare it with a connective tissue graft (CTG), when used with a double papillary flap. Materials and Methods: Sixteen patients with bilateral class I or II gingival recessions were selected. A total of 32 recessions were treated and randomly assigned into the test and contralateral recessions into the control group. In the control group, the exposed root surfaces were treated by the placement of a CTG in combination with a double papillary flap; and in the test group, an ADM allograft was used as a substitute for palatal donor tissue. Probing depth, clinical attachment level, width of keratinized tissue (KT), recession height and width were measured before, and after 2 weeks and 6 months of surgery. Results: There were no statistically significant differences between the test and control groups in terms of recession reduction, clinical attachment gain, and reduction in probing depth. The control group had a statistically significant increased area of KT after 6 months compared to the test group. Conclusion: ADM allograft can be considered as a substitute for palatal donor tissue in root coverage procedure. PMID:24130587
Maroo, Sneha; Murthy, K Raja V
2014-01-01
The need to increase the predictability of periodontal regeneration has encouraged clinicians and researchers to employ cell-stimulating proteins in combination with osteoconductive scaffolds, based on the principles of tissue engineering. The purpose of this clinical and radiographic study was to compare the regenerative potential of the combination of β-tricalcium phosphate (β-TCP) and recombinant human platelet-derived growth factor BB (rhPDGF-BB) in the grafting of intraosseous defects with the established technique of bone grafting with (β-TCP alone. A total of 30 sites from 15 patients with infrabony defects in two different quadrants were selected, and the sites were randomly divided into test sites (rhPDGF + β-TCP) and control sites (β-TCP alone) using a split-mouth design. Clinical parameters, including probing pocket depth, clinical attachment level, and gingival recession, were recorded at baseline, 6 months, and 9 months. Radiographic evaluation was carried out to evaluate defect fill, change in alveolar crest height, and percentage of defect fill at baseline, 6 months, and 9 months. Both the experimental groups showed statistically significant reduction in probing pocket depth and gain in clinical attachment level. On intergroup comparison, sites treated with rhPDGF + β-TCP demonstrated a significantly greater pocket depth reduction (P < .05) and greater gain in clinical attachment level (P < .01). Mean percentage defect fill was significantly greater in test sites as compared with control sites at 6 and 9 months (P < .01). rhPDGF + β-TCP-treated sites demonstrated a significant gain in mean alveolar crest height at 6 and 9 months (P < .05), while β-TCP-treated sites demonstrated crestal resorption. Both groups demonstrated potential in enhancing periodontal regeneration; however, on comparison between the two groups, the results obtained by rhPDGF + β-TCP were significantly better with respect to both clinical and radiographic parameters.
Ghijselings, E; Coucke, W; Verdonck, A; Teughels, W; Quirynen, M; Pauwels, M; Carels, C; van Gastel, J
2014-02-01
The aim of this prospective study was to monitor patients' microbiological and clinical periodontal parameters prior and up to 2 years after orthodontic treatment. Twenty-four adolescents were treated with brackets. Fourteen of them received bands on upper first molars for extra-oral force application before bonding brackets to the remaining teeth. Microbiology, periodontal probing depth, bleeding on probing (BOP), and gingival crevicular fluid (GCF) flow were assessed at baseline (T1), bracket removal (T2), and 2 years post-treatment (T3). A statistical comparison was made over time and between bands and brackets. A significant increase from T1 to T2 and a decrease from T2 to T3 in pathogenicity of plaque were noted. No significant difference was observed concerning supragingival colony-forming units (CFU) ratio (aerobe/anaerobe) between T3 and T1. However, the subgingival CFU ratio (aerobe/anaerobe) at T3 did significantly differ from the ratio at T1. Periodontal probing depth, BOP and GCF flow showed a significant increase between T1 and T2 and a reduction between T2 and T3, resulting in the absence of significant differences between T3 and T1, except for BOP at banded sites. Placement of fixed appliances has an impact on periodontal parameters. The results showed that not all parameters were normalized at T3, indicating that the changes are only partially reversible. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Qiu, Jianrong; Shen, Yi; Shangguan, Ziwei; Bao, Wen; Yang, Shanshan; Li, Peng; Ding, Zhihua
2018-04-01
Although methods have been proposed to maintain high transverse resolution over an increased depth range, it is not straightforward to scale down the bulk-optic solutions to minimized probes of optical coherence tomography (OCT). In this paper, we propose a high-efficient fiber-based filter in an all-fiber OCT probe to realize an extended depth of focus (DOF) while maintaining a high transverse resolution. Mode interference in the probe is exploited to modulate the complex field with controllable radial distribution. The principle of DOF extension by the fiber-based filter is theoretically analyzed. Numerical simulations are conducted to evaluate the performances of the designed probes. A DOF extension ratio of 2.6 over conventional Gaussian beam is obtainable in one proposed probe under a focused beam diameter of 4 . 6 μm. Coupling efficiencies of internal interfaces of the proposed probe are below -40 dB except the last probe-air interface, which can also be depressed to be -44 dB after minor modification in lengths for the filter. Length tolerance of the proposed probe is determined to be - 28 / + 20 μm, which is readily satisfied in fabrication. With the merits of extended-DOF, high-resolution, high-efficiency and easy-fabrication, the proposed probe is promising in endoscopic applications.
Tanner, Dwight Q.; Bragg, Heather M.
2002-03-06
At times in July and August 2001, the total-dissolved-gas probe at Warrendale could not be positioned below the minimum compensation depth because the river was too shallow at that location. Consequently, degassing at probe depth may have occurred, and total dissolved gas may have been larger in locations with greater depths.
Dental and periodontal complications of lip and tongue piercing: prevalence and influencing factors.
Plessas, A; Pepelassi, E
2012-03-01
The aim of this study was to compare the prevalence of lip and tongue piercing complications and explore the effect of ornament time wear period, habits, ornament morphology and periodontal biotype on the development of complications. One hundred and ten subjects with 110 lip and 51 tongue piercings were assessed for abnormal toothwear and/or tooth chipping/cracking (dental defects), gingival recession, clinical attachment loss and probing depth of teeth adjacent to the pierced site. Piercing habits (biting, rolling, stroking, sucking) were recorded. Wear time and habits significantly affected the prevalence of dental defects and gingival recession. Pierced site significantly affected dental defects prevalence, with greater prevalence for tongue than lip piercing. Wear time significantly affected attachment loss and probing depth. Attachment loss and probing depth did not significantly differ between tongue and lip piercings. Gingival recession was significantly associated with ornament height closure and stem length of tongue ornaments. Periodontal biotype was not significantly associated with gingival recession, attachment loss and probing depth. Dental defects prevalence is greater for tongue than lip piercing. Gingival recession is similar for tongue and lip piercing. Longer wear time of tongue and lip piercing is associated with greater prevalence of dental defects and gingival recession, as well as greater attachment loss and probing depth of teeth adjacent to pierced sites. Ornament morphology affects gingival recession prevalence. © 2012 Australian Dental Association.
Gupta, Swyeta Jain; Jhingran, Rajesh; Gupta, Vivek; Bains, Vivek Kumar; Madan, Rohit; Rizvi, Iram
2014-07-01
To evaluate and compare the efficacy of platelet-rich fibrin (PRF) with enamel matrix derivative (EMD; Emdogain) in the treatment of periodontal intrabony defects in patients with chronic periodontitis, six months after surgery. Forty-four (44) intrabony defects in 30 patients (15 males) were randomly allocated into two treatment groups: EMD (n = 22) and PRF (n = 22). Measurement of the defects was done using clinical and cone beam computed tomography at baseline and 6 months. Clinical and radiographic parameters such as probing depth, clinical attachment level, intrabony defect depth and defect angle, were recorded at baseline and 6 months post-operatively. Within group change was evaluated using the Wilcoxon signed rank test. Intergroup comparisons were made using the Mann-Whitney U test. Postsurgical measurements revealed that there was an equal reduction in probing depth and a greater but statistically non-significant attachment gain for the Emdogain group when compared to the platelet-rich fibrin group. The Emdogain group presented with significantly greater percentage defect resolution (43.07% ± 12.21) than did the platelet-rich fibrin group (32.41% ± 14.61). Post-operatively the changes in defect width and defect angle were significant in both groups, but upon intergroup comparison they were found to be statistically non-significantly different. Both Emdogain and platelet-rich fibrin were effective in the regeneration of intrabony defects. Emdogain was significantly superior in terms of percentage defect resolution.
Pippi, Roberto
2013-01-01
Summary Aim The primary aim of the present study was to validate the effectiveness of a personalized device able to guide periodontal probing in evaluation of second molar periodontal healing after adjacent third molar surgical extraction. Secondarily, the study analyzed if any patient and tooth related factors affected the second molar periodontal healing as well as if they were able to affect the periodontal probing depth performed with or without the personalized device. Materials and methods Thirty-five lower second molars were evaluated after extraction of the adjacent third molar. Pre-operative as well as 3 and 12 month post-operative probing depths of the distal surface of the second molar were evaluated. All measurements were taken by two different methods: standard two-point and four-point probing using a personalized onlay-type guide. Periapical radiographs were also evaluated. The Pearson product moment and the general linear model with backward stepwise procedure were used for inferential statistics. Results The mean 12-month post-operative probing depth/mean pre-operative probing depth ratio obtained with the guided probing method showed a highly significant effect on the 12-month radiographic post-operative/pre-operative radiographic measure ratio. None of the examined patient- or tooth-related factors showed a significant effect on pre-operative/12-month post-operative radiographic measure ratio. Conclusions The use of the proposed personalized device seems to provide a more reliable estimate of second molar periodontal healing after adjacent third molar surgical extraction. No patient-or tooth-related factors seem to be able to affect either second molar periodontal healing or probing depth measures obtained with or without the personalized device in individuals younger than 25 years old. It can be therefore recommended that lower third molar surgical extraction be performed in young adults. PMID:24611086
SPRUCE S1 Bog Peat Depth Determined by Push Probe and GPR: 2009-2010
Slater, L. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A.; Hanson, P. J. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A.; Hook, L. A. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A.
2012-01-01
This data set reports the thickness of peat for the S1 Bog measured directly with manual push probes on September 21 and 22, 2009, and measured by ground penetrating radar (GPR) across transects from January 26 to February 2, 2010 and June 2 to June 9, 2010. Also included are interpolated values of peat depth from both probe and GPR data for the S1 Bog at 1 meter square horizontal resolution.
Resolution of localized chronic periodontitis associated with longstanding calculus deposits.
Lai, Pin-Chuang; Walters, John D
2014-01-01
This report, which is based on nonstandardized serial radiographs obtained over a period of 15 years, documents a case of localized chronic periodontitis associated with progressive deposition of calculus on the distal aspect of a mandibular second molar. The site was treated by scaling and root planing, followed by a course of adjunctive systemic azithromycin. Treatment yielded favorable reductions in probing depth and clinical inflammation, leaving only few isolated sites with pockets no deeper than 4 mm. Two years after completion of active treatment, there was radiographic evidence of increased bone density distal to the second molar.
Differential NICMOS Spectrophotometry at High S/N
NASA Technical Reports Server (NTRS)
Gilliland, Ronald L.
2006-01-01
Transiting extrasolar planets present an opportunity for probing atmospheric conditions and constituents by taking advantage of different apparent radii, hence transit depth as a function of wavelength. Strong near-IR bands should support detection of water vapor via G141 spectroscopy of the bright star HD 209458 (H=6.13) by comparing in- and out-of-transit ratios of in- and out-of-band spectral intensity ratios. The reduction and analysis of science observations in which the goal is to support 1 part in 10,000, or better, development of spectral diagnostics using NICMOS grism-based spectroscopy is discussed.
Efficacy of subantimicrobial-dose doxycycline against nitrosative stress in chronic periodontitis.
Pârvu, Alina Elena; Alb, Sandu Florin; Crăciun, Alexandra; Taulescu, Marian Aurel
2013-02-01
To evaluate the effectiveness of subantimicrobial-dose doxycycline (SDD) as an adjunct to scaling and root planing (SRP) treatment against the nitrosative stress of moderate to advanced chronic periodontitis. Adults with untreated chronic periodontitis (n=174) were randomly administered SRP+SDD (n=87) (20 mg of doxycycline twice daily) or SRP+placebo (n=87) treatment for 3 months. At baseline and after 3 months, the probing depths (PD), bleeding on probing (BOP) and clinical attachment level (CAL) were measured, and a gingivomucosal biopsy was collected to assay the induction of nitric oxide synthase (iNOS) and 3-nitrotyrosine (3NT), and blood was collected to assay for total nitrites and nitrates (NO(x)) and 3NT. Compared to baseline, at the completion of treatment, significant decreases in the levels of tissue iNOS and 3NT and serum NO(x) and 3NT were observed in both groups. SRP+SDD yielded a greater reduction in the gingivomucosal and serum nitrosative stress markers than did SRP+placebo. PD, BOP, and CAL reduction were correlated with the nitrosative stress parameters. On a short-term basis, SDD therapy may be used as an adjunct to SRP treatment against nitrosative stress in moderate to advanced chronic periodontitis.
Nagarjuna Reddy, Y. V.; Deepika, P. C.; Venkatesh, M. P.; Rajeshwari, K. G.
2016-01-01
Background: The formation of new connective periodontal attachment is contingent upon the elimination or marked reduction of pathogens at the treated periodontal site. An anti-microbial agent, i.e. moxifloxacin has been incorporated into the bone graft to control infection and facilitate healing during and after periodontal therapy. Materials and Methods: By purposive sampling, 15 patients with at least two contralateral vertical defect sites were selected. The selected sites in each individual were divided randomly into test and control sites according to split-mouth design. Test site received moxifloxacin-hydroxyapatite composite graft and control site received hydroxyapatite-placebo gel composite graft. Probing depth (PD) and Clinical attachment level (CAL) were assessed at baseline, 3, 6, 9, and 12 months. Bone probing depth (BPD) and hard tissue parameters such as amount of defect fill, percentage of defect fill, and changes in alveolar crest were assessed at baseline, 6, and 12 months. Changes in subgingival microflora were also assessed by culturing the subgingival plaque samples at baseline and at 3-month follow-up. The clinical, radiographic, and microbiological data obtained were subjected to statistical analysis using descriptive statistics, paired sample t-test, independent t-test, and contingency test. Results: On intragroup comparison at test and control sites, there was a significant improvement in all clinical and radiographic parameters. However, on intergroup comparison of the same, there was no statistically significant difference between test and control sites at any interval. Although test sites showed slightly higher amount of bone fill, it was not statistically significant. There was a significant reduction in the counts of Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis at both sites from baseline to 3 months. In addition, there was a significant reduction at test sites as compared to control sites at 3-month follow-up (P = 0.003 and P = 0.013). Conclusion: The reduction in microbial counts found in test sites at 3-month follow-up could not bring similar significant improvements in the clinical and radiographic parameters though the test sites showed slightly higher bone fill. PMID:27630501
Brinkhoff, James; Hornbuckle, John; Dowling, Thomas
2017-12-26
Multisensor capacitance probes (MCPs) have traditionally been used for soil moisture monitoring and irrigation scheduling. This paper presents a new application of these probes, namely the simultaneous monitoring of ponded water level, soil moisture, and temperature profile, conditions which are particularly important for rice crops in temperate growing regions and for rice grown with prolonged periods of drying. WiFi-based loggers are used to concurrently collect the data from the MCPs and ultrasonic distance sensors (giving an independent reading of water depth). Models are fit to MCP water depth vs volumetric water content (VWC) characteristics from laboratory measurements, variability from probe-to-probe is assessed, and the methodology is verified using measurements from a rice field throughout a growing season. The root-mean-squared error of the water depth calculated from MCP VWC over the rice growing season was 6.6 mm. MCPs are used to simultaneously monitor ponded water depth, soil moisture content when ponded water is drained, and temperatures in root, water, crop and ambient zones. The insulation effect of ponded water against cold-temperature effects is demonstrated with low and high water levels. The developed approach offers advantages in gaining the full soil-plant-atmosphere continuum in a single robust sensor.
Zhang, Z; Zheng, Y; Bian, X
2016-06-01
The results of recent published studies focusing on the effect of azithromycin as an adjunct to scaling and root planing (SRP) in the treatment of chronic periodontitis are inconsistent. We conducted a meta-analysis of randomized controlled clinical trials to examine the effect of azithromycin combined with SRP on periodontal clinical parameters as compared to SRP alone. An electronic search was carried out on Pubmed, Embase and the Cochrane Central Register of Controlled Trials from their earliest records through December 28, 2014 to identify studies that met pre-stated inclusion criteria. Reference lists of retrieved articles were also reviewed. Data were extracted independently by two authors. Either a fixed- or random-effects model was used to calculate the overall effect sizes of azithromycin on probing depth, attachment level (AL) and bleeding on probing (BOP). Heterogeneity was evaluated using the Q test and I(2) statistic. Publication bias was evaluated by Begg's test and Egger's test. A total of 14 trials were included in the meta-analysis. Compared with SRP alone, locally delivered azithromycin plus SRP statistically significantly reduced probing depth by 0.99 mm (95% CI 0.42-1.57) and increased AL by 1.12 mm (95% CI 0.31-1.92). In addition, systemically administered azithromycin plus SRP statistically significantly reduced probing depth by 0.21 mm (95% CI 0.12-0.29), BOP by 4.50% (95% CI 1.45-7.56) and increased AL by 0.23 mm (95% CI 0.07-0.39). Sensitivity analysis yielded similar results. No evidence of publication bias was observed. The additional benefit of systemic azithromycin was shown at the initially deep probing depth sites, but not at shallow or moderate sites. The overall effect sizes of systemic azithromycin showed a tendency to decrease with time, and meta-regression analysis suggested a negative relation between the length of follow-up and net change in probing depth (r = -0.05, p = 0.02). This meta-analysis provides further evidence that azithromycin used as an adjunct to SRP significantly improves the efficacy of non-surgical periodontal therapy on reducing probing depth, BOP and improving AL, particularly at the initially deep probing depth sites. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lupini, A.R.; de Jonge, N.
2012-01-01
Aberration-correction reduces the depth of field in scanning transmission electron microscopy (STEM) and thus allows three-dimensional imaging by depth-sectioning. This imaging mode offers the potential for sub-Ångstrom lateral resolution and nanometer-scale depth sensitivity. For biological samples, which may be many microns across and where high lateral resolution may not always be needed, optimizing the depth resolution even at the expense of lateral resolution may be desired, aiming to image through thick specimens. Although there has been extensive work examining and optimizing the probe formation in two-dimensions, there is less known about the probe shape along the optical axis. Here the probe shape is examined in three-dimensions in an attempt to better understand the depth-resolution in this mode. Examples are presented of how aberrations change the probe shape in three-dimensions, and it is found that off-axial aberrations may need to be considered for focal series of large areas. It is shown that oversized or annular apertures theoretically improve the vertical resolution for 3D imaging of nanoparticles. When imaging nanoparticles of several nanometer size, regular STEM can thereby be optimized such that the vertical full width at half maximum approaches that of the aberration corrected STEM with a standard aperture. PMID:21878149
Application study of the optical biopsy system for small experimental animals
NASA Astrophysics Data System (ADS)
Sato, Hidetoshi; Suzuki, Toshiaki; Morita, Shin-ichi; Maruyama, Atsushi; Shimosegawa, Toru; Matsuura, Yuji; Kanai, Gen'ichi; Ura, Nobuo; Masutani, Koji; Ozaki, Yukihiro
2008-02-01
An optical biopsy system for small experimental animals has been developed. The system includes endoscope probe, portable probe and two kinds of miniaturized Raman probes. The micro Raman probe (MRP) is made of optical fibers and the ball lens hollow optical fiber Raman probe (BHRP) is made of hollow fiber. The former has large focal depth and suitable to measure average spectra of subsurface tissue. The latter has rather small focal depth and it is possible to control focal length by selecting ball lens attached at the probe head. It is suitable to survey materials at the fixed depth in the tissue. The system is applied to study various small animal cancer models, such as esophagus and stomach rat models and subcutaneous mouse models of pancreatic cancers. In the studies of subcutaneous tumor model mouse, it is suggested that protein conformational changes occur in the tumor tissue within few minutes after euthanasia of the mouse. No more change is observed for the following ten minutes. Any alterations in the molecular level are not observed in normal skin, muscle tissues. Since the change completes in such a short time, it is suggested that this phenomenon caused by termination of blood circulation.
Saberi, Bardia Vadiati; Nemati, Somayeh; Malekzadeh, Meisam; Javanmard, Afrooz
2017-01-01
Assessment of alveolar bone level in periodontitis is very important in determining prognosis and treatment plan. Panoramic radiography is a diagnostic tool used to screen patients. The aim of the present study was to assess the diagnostic value of digital panoramic radiography in angular bony defects with 5 mm or deeper pocket depth in mandibular molars. In this cross-sectional study, ninety angular bony defects in mandibular molars teeth with 5 mm or deeper pocket depth were selected in sixty patients with the diagnosis of chronic periodontitis. Before surgery, bone probing was performed. During the surgery, the vertical distance from cementoenamel junction to the most apical part of bony defect was measured using a Williams probe and this measurements were employed as gold standard. This distance was measured on the panoramic radiographs by a Digital Calliper and Digital Ruler. All data were compare dusing independent samples t -test and Pearson's correlation coefficient. No significant difference was found between the results of bone probing and intra-surgical measurements ( P = 0.377). The mean defect depth determined by Digital Caliper and Digital Ruler on panoramic radiographs was significantly less than surgical measurements ( P < 0.001). The correlation between bone probing and surgical measurements in determining the defect depth was strong ( r = 0.98, P < 0.001). Radiographic measurements made by Digital Ruler ( r = 0.86), comparing to Digital Caliper ( r = 0.79), showed a higher degree of correlation with surgical measurements. Based on this study, bone probing is a reliable method in vertical alveolar bone defect measurements. While the information obtained from digital panoramic radiographs should be used with caution and the ability of digital panoramic radiography in the determination of defect depth is limited.
Sanz-Sánchez, Ignacio; Ortiz-Vigón, Alberto; Herrera, David; Sanz, Mariano
2016-07-01
The objective of this study was to assess the microbiological effects and recolonization patterns after non-surgical periodontal treatment protocol based on the adjunctive use of erbium-doped yttrium aluminium garnet (Er:YAG) laser. Patients diagnosed with chronic periodontitis were randomly assigned to two different treatment protocols: test, full-mouth subgingival ultrasonic instrumentation followed by Er-YAG laser application 1 week later to sites with initial probing pocket depth ≥4.5 mm; and control, full-mouth ultrasonic subgingival instrumentation within 1 week. Clinical (at sampled sites) and microbiological (culture-based) parameters were recorded at baseline and 3 and 12 months. Microbiological variables included total counts, frequency of detection, proportions and counts of target species. Results from 19 test and 21 control patients were compared. Minor changes were observed for total colony-forming units, with no differences between groups. For the frequency of detection, a limited and similar impact in both groups was observed for the most prevalent (over 80 %) periodontal pathogens (Porphyromonas gingivalis, Prevotella intermedia, Fusobacterium nucleatum). For proportions, reductions in P. gingivalis occurred at 3 months, both in the test and control groups (from 16.3 to 10 % and 16 to 14.8 %, respectively), although these differences were not statistically significant. At 12 months, the test group showed a statistically significant greater reduction in probing depth for the sampled sites. The adjunctive use of Er:YAG laser when compared with conventional ultrasonic debridement did not provide a microbiological added benefit. Even though some clinical benefits with the adjunctive laser application were identified when comparing both treatment protocols, there were no differences in microbiological outcomes or in the bacterial recolonization patterns.
Monte Carlo modeling of ultrasound probes for image guided radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazalova-Carter, Magdalena, E-mail: bazalova@uvic.ca; Schlosser, Jeffrey; Chen, Josephine
2015-10-15
Purpose: To build Monte Carlo (MC) models of two ultrasound (US) probes and to quantify the effect of beam attenuation due to the US probes for radiation therapy delivered under real-time US image guidance. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their megavoltage (MV) CT images acquired in a Tomotherapy machine with a 3.5 MV beam in the EGSnrc, BEAMnrc, and DOSXYZnrc codes. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2 andmore » 8.0 g/cm{sup 3}. Beam attenuation due to the US probes in horizontal (for both probes) and vertical (for the X6-1 probe) orientation was measured in a solid water phantom for 6 and 15 MV (15 × 15) cm{sup 2} beams with a 2D ionization chamber array and radiographic films at 5 cm depth. The MC models of the US probes were validated by comparison of the measured dose distributions and dose distributions predicted by MC. Attenuation of depth dose in the (15 × 15) cm{sup 2} beams and small circular beams due to the presence of the probes was assessed by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities in the X6-1 and C5-2 probes were found to be 4.8 and 5.2 g/cm{sup 3}, respectively. Dose profile differences between MC simulations and measurements of less than 3% for US probes in horizontal orientation were found, with the exception of the penumbra region. The largest 6% dose difference was observed in dose profiles of the X6-1 probe placed in vertical orientation, which was attributed to inadequate modeling of the probe cable. Gamma analysis of the simulated and measured doses showed that over 96% of measurement points passed the 3%/3 mm criteria for both probes placed in horizontal orientation and for the X6-1 probe in vertical orientation. The X6-1 probe in vertical orientation caused the highest attenuation of the 6 and 15 MV beams, which at 10 cm depth accounted for 33% and 43% decrease compared to the respective (15 × 15) cm{sup 2} open fields. The C5-2 probe in horizontal orientation, on the other hand, caused a dose increase of 10% and 53% for the 6 and 15 MV beams, respectively, in the buildup region at 0.5 cm depth. For the X6-1 probe in vertical orientation, the dose at 5 cm depth for the 3-cm diameter 6 MV and 5-cm diameter 15 MV beams was attenuated compared to the corresponding open fields to a greater degree by 65% and 43%, respectively. Conclusions: MC models of two US probes used for real-time image guidance during radiotherapy have been built. Due to the high beam attenuation of the US probes, the authors generally recommend avoiding delivery of treatment beams that intersect the probe. However, the presented MC models can be effectively integrated into US-guided radiotherapy treatment planning in cases for which beam avoidance is not practical due to anatomy geometry.« less
The effect of periodontal therapy on intra-oral halitosis: a case series.
Erovic Ademovski, Seida; Mårtensson, Carina; Persson, G Rutger; Renvert, Stefan
2016-05-01
The aim of this study was to evaluate the effects of non-surgical periodontal therapy on intra-oral halitosis 3 months after therapy. Sixty-eight adults with intra-oral halitosis were included in a case series. Intra-oral halitosis was evaluated at baseline, and at 3 months after treatment using the organoleptic scores (OLS), Halimeter ® , and a gas chromatograph. Significant reductions for OLS (p < 0.01), total sum of volatile sulphur compounds (T-VSC) (p < 0.01) and methyl mercaptan (MM) (p < 0.05) values were found after treatment. Hydrogen sulphide (H 2 S) levels were not significantly reduced. The numbers of probing pockets 4 mm, 5 mm and 6 mm were significantly reduced as a result of therapy (p < 0.001). Bleeding on probing (BOP) and plaque indices were also significantly reduced (p < 0.001). For the 34 individuals with successful periodontal treatment (BOP<20% and a ≥50% reduction of total pocket depth) reductions in OLS (p < 0.01) and T-VSC scores (p < 0.01) were found. Eleven individuals were considered effectively treated for intra-oral halitosis presenting with a T-VSC value <160 ppb, a H 2 S value <112 ppb and a MM value <26 ppb. Non-surgical periodontal therapy resulted in reduction of OLS, MM and T-VSC values 3 months after therapy. Few individuals were considered as effectively treated for intra-oral halitosis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Theodoro, Letícia Helena; Assem, Naida Zanini; Longo, Mariéllen; Alves, Márcio Luiz Ferro; Duque, Cristiane; Stipp, Rafael Nobrega; Vizoto, Natália Leal; Garcia, Valdir Gouveia
2018-06-01
The aim of this study was to evaluate the effects of non-surgical periodontal therapies on smokers with chronic periodontitis, involving multiple adjunctive applications of antimicrobial photodynamic therapy (aPDT), and systemic metronidazole (MTZ) with amoxicillin (AMX). All participants were treated with scaling and root planing (SRP). Seventeen patients received 400 mg of MTZ and 500 mg of AMX three times per day for 7 days (MTZ + AMX). Additionally, 17 patients received a placebo, and 17 patients were treated with three applications of aPDT (immediately, 48 h and 96 h after SRP). Clinical and microbiological examinations were performed at baseline and at 90 and 180 days post-therapy. Subgingival samples were analyzed using real-time polymerase chain reaction. After 180 days, the patients in groups MTZ + AMX and aPDT had significantly lower mean probing depths, more clinical attachment level gains and less bleeding on probing. At 180 days, in the moderate pocket there was a reduction in the levels of Porphyromonas gingivalis and Prevotella nigrescens in the MTZ + AMX group, while group aPDT showed a reduction in Prevotella nigrescens. Furthermore, at 180 days, in the deep pocket a reduction in Porphyromonas gingivalis, Prevotella intermedia and Prevotella nigrescens was observed in group MTZ + AMX, as well as a reduction in the levels of Prevotella intermedia and Prevotella nigrescens in group aPDT. In smokers with periodontitis, the MTZ + AMX and aPDT treatments significantly improved the effects of SRP. Copyright © 2018 Elsevier B.V. All rights reserved.
D-region blunt probe data analysis using hybrid computer techniques
NASA Technical Reports Server (NTRS)
Burkhard, W. J.
1973-01-01
The feasibility of performing data reduction techniques with a hybrid computer was studied. The data was obtained from the flight of a parachute born probe through the D-region of the ionosphere. A presentation of the theory of blunt probe operation is included with emphasis on the equations necessary to perform the analysis. This is followed by a discussion of computer program development. Included in this discussion is a comparison of computer and hand reduction results for the blunt probe launched on 31 January 1972. The comparison showed that it was both feasible and desirable to use the computer for data reduction. The results of computer data reduction performed on flight data acquired from five blunt probes are also presented.
Pradeep, A R; Patnaik, Kaushik; Nagpal, Kanika; Karvekar, Shruti; Guruprasad, C N; Kumaraswamy, K M
2017-10-01
The aim of this study is to investigate efficacy of metformin (MF) 1% gel as an adjunct to scaling and root planing (SRP) in the treatment of moderate and severe chronic periodontitis (CP). Seventy patients were categorized into two treatment groups: 1) SRP plus 1% MF and 2) SRP plus placebo. Clinical parameters were recorded at baseline and 3, 6, and 9 months. They included plaque index (PI), modified sulcus bleeding index (mSBI), probing depth (PD), and clinical attachment level (CAL). Radiologic assessment of intrabony defects (IBDs) and percentage defect depth reduction (DDR%) was done at baseline and 6- and 9-month intervals using computer-aided software. PD, CAL, and DDR% were evaluated in two subgroups in both the placebo and MF group: 1) initial PD of 5 to 7 mm and 2) initial PD of >7 mm. Mean PD reduction and mean CAL gain was found to be greater in the MF group than the placebo group at all visits. Clinical parameters (PD, CAL) in both subgroups, with initial PDs of 5 to 7 and >7 mm, showed significant improvement in the 1% MF group compared with the placebo group. A significantly greater mean DDR% was found in the MF group than the placebo group at 6 and 9 months in both subgroups, 5 to 7 and >7 mm of initial PD. There was a greater decrease in PD and more CAL gain with significant IBD depth reduction at sites treated with SRP plus locally delivered MF in patients with CP in both initial PD = 5 to 7 and >7 mm subgroups compared with placebo.
Sanjeeva, Shilpa Kammaradi; Korrapati, Swathi; Nair, Chandrasekhar B; Rao, P V Subba; Pullela, Phani Kumar; Vijayalakshmi, U; Siva, Ramamoorthy
2014-07-01
Donor-linker-acceptor (DSSA) is a concept in fluorescence chemistry with acceptor being a fluorescent compound (FRET) or quencher. The DSSA probes used to measure thiol levels in vitro and in vivo. The reduction potential of these dyes are in the range of -0.60 V, much lower than the best thiol reductant reported in literature, the DTT (-0.33 V). DSSA disulphide having an unusually low reduction potential compared to the typical thiol reductants is a puzzle. Secondly, DSSA probes have a cyclized rhodamine ring as acceptor which does not have any spectral overlap with fluorescein, but quenches its absorbance and fluorescence. To understand the structural features of DSSA probes, we have synthesized DSSANa and DSSAOr. The calculated reduction potential of these dyes suggest that DSSA probes have an alternate mechanism from the FRET based quenching, namely hydrophobic interaction or dye to dye quenching. The standard reduction potential change with increasing complexity and steric hindrance of the molecule is small, suggesting that ultra- low Eo' has no contribution from the disulphide linker and is based on structural interactions between fluorescein and cyclized rhodamine. Our results help to understand the DSSA probe quenching mechanism and provide ways to design fluorescent probes.
NASA Astrophysics Data System (ADS)
Yin, Biwei; Liang, Chia-Pin; Vuong, Barry; Tearney, Guillermo J.
2017-02-01
Conventional OCT images, obtained using a focused Gaussian beam have a lateral resolution of approximately 30 μm and a depth of focus (DOF) of 2-3 mm, defined as the confocal parameter (twice of Gaussian beam Rayleigh range). Improvement of lateral resolution without sacrificing imaging range requires techniques that can extend the DOF. Previously, we described a self-imaging wavefront division optical system that provided an estimated one order of magnitude DOF extension. In this study, we further investigate the properties of the coaxially focused multi-mode (CAFM) beam created by this self-imaging wavefront division optical system and demonstrate its feasibility for real-time biological tissue imaging. Gaussian beam and CAFM beam fiber optic probes with similar numerical apertures (objective NA≈0.5) were fabricated, providing lateral resolutions of approximately 2 μm. Rigorous lateral resolution characterization over depth was performed for both probes. The CAFM beam probe was found to be able to provide a DOF that was approximately one order of magnitude greater than that of Gaussian beam probe. By incorporating the CAFM beam fiber optic probe into a μOCT system with 1.5 μm axial resolution, we were able to acquire cross-sectional images of swine small intestine ex vivo, enabling the visualization of subcellular structures, providing high quality OCT images over more than a 300 μm depth range.
Sanapala, Krishna K; Hewaparakrama, Kapila; Kang, Kyung A
2011-01-01
Magnetic nanoparticle mediated low heat hyperthermia (42~45( o )C) via alternating electromagnetic (AEM) energy is a promising, cancer specific and minimally-invasive cancer therapy. Iron oxide particles frequently used for this therapy are non-toxic and already used as a contrast agent for magnetic resonance imaging. One important issue in the hyperthermia is applying an appropriate amount of energy to the tumor at various sizes and depths, with a minimal damage to normal tissue. For the therapy to be desirable, the AEM energy applicator needs to be non-invasive and user-friendly. To better understand the effect of the probe on the magnetic field distribution, computer simulation was performed for the field distribution by probes with various configurations. In a solenoid-type probe, the field is mainly inside the probe and, therefore, is difficult to use on body. A pancake-shaped probe is easy to use but the field penetration is shallow and, thus, may better serve surface tumor treatment. A sandwich probe, composed of two pancake probes, has a penetration depth deeper than a pancake probe. The results also showed that the spacing between two adjacent coils and the number of coil turns are very important for controlling the field penetration depth and strength. Experiments were also performed to study the effects of the size and concentration of iron oxide nanoparticles on heating. Among the tested particle sizes of 10~50 nm, 30 nm particles showed the best heating for the same mass.
Scanning fiber angle-resolved low coherence interferometry
Zhu, Yizheng; Terry, Neil G.; Wax, Adam
2010-01-01
We present a fiber-optic probe for Fourier-domain angle-resolved low coherence interferometry for the determination of depth-resolved scatterer size. The probe employs a scanning single-mode fiber to collect the angular scattering distribution of the sample, which is analyzed using the Mie theory to obtain the average size of the scatterers. Depth sectioning is achieved with low coherence Mach–Zehnder interferometry. In the sample arm of the interferometer, a fixed fiber illuminates the sample through an imaging lens and a collection fiber samples the backscattered angular distribution by scanning across the Fourier plane image of the sample. We characterize the optical performance of the probe and demonstrate the ability to execute depth-resolved sizing with subwavelength accuracy by using a double-layer phantom containing two sizes of polystyrene microspheres. PMID:19838271
Motorized photoacoustic tomography probe for label-free improvement in image quality
NASA Astrophysics Data System (ADS)
Sangha, Gurneet S.; Hale, Nick H.; Goergen, Craig J.
2018-02-01
One of the challenges in high-resolution in vivo lipid-based photoacoustic tomography (PAT) is improving penetration depth and signal-to-noise ratio (SNR) past subcutaneous fat absorbers. A potential solution is to create optical manipulation techniques to maximize the photon density within a region of interest. Here, we present a motorized PAT probe that is capable of tuning the depth in which light is focused, as well as substantially reducing probe-skin artifacts that can obscure image interpretation. Our PAT system consists of a Nd:YAG laser (Surelite EX, Continuum) coupled with a 40 MHz central frequency ultrasound transducer (Vevo2100, FUJIFILM Visual Sonics). This system allows us to deliver 10 Hz, 5 ns light pulses with fluence of 40 mJ/cm2 to the tissue interest and reconstruct PAT and ultrasound images with axial resolutions of 125 µm and 40 µm, respectively. The motorized PAT holder was validated by imaging a polyethylene-50 tubing embedded polyvinyl alcohol phantom and periaortic fat on apolipoprotein-E deficient mice. We used 1210 nm light for this study, as this wavelength generates PAT signal for both lipids and polyethylene-50 tubes. Ex vivo results showed a 2 mm improvement in penetration depth and in vivo experiments showed an increase in lipid SNR of at least 62%. Our PAT probe also utilizes a 7 μm aluminum filter to prevent in vivo probe-skin reflection artifacts that have been previously resolved using image post-processing techniques. Using this optimized PAT probe, we can direct light to various depths within tissue to improve image quality and prevent reflection artifacts.
Aren, Gamze; Sepet, Elif; Ozdemir, Didem; Dinççağ, Nevin; Güvener, Bora; Firatli, Erhan
2003-12-01
The aim of this study was to determine whether detectable periodontal destruction and alterations in the salivary status were present with duration of diabetes in children with type 1 insulin-dependent diabetes mellitus (type 1 DM) as compared to healthy controls. Sixteen newly diagnosed children with DM (group 1), 16 children with type 1 DM of long duration (group 2), and 16 healthy children (group 3) participated in the study. Periodontal health was assessed by plaque index, gingival index, bleeding on probing, and periodontal probing depths. The flow rate, pH, buffering capacity, and peroxidase activities of stimulated saliva were determined. The data were analyzed by Kruskall-Wallis, Student t test, and Pearson's correlation analysis. The mean values for fasting blood glucose levels for the diabetic groups were significantly higher than for the controls. The mean values for salivary buffering capacities and salivary pH from the diabetic groups were significantly lower than for the controls. The plaque index values for the diabetic groups were significantly higher than for the controls. The mean gingival index value for group 1 was significantly lower than for group 2. The mean periodontal probing depths for group 1 were similar to those of the non-DM controls, but the mean periodontal probing depths for group 2 were significantly greater than for both the non-DM controls and group 1. Group 1 had significantly greater bleeding on probing scores than did the other groups (P < 0.05). The glycemic status of the diabetic subjects affects the periodontal probing depths, salivary pH, buffering capacity, and peroxidase activity.
7 CFR 800.84 - Inspection of grain in land carriers, containers, and barges in single lots.
Code of Federal Regulations, 2011 CFR
2011-01-01
... each probe, the grain shall be sampled as thoroughly as possible with an approved probe. The grain in... show a statement, as specified in the instructions, indicating the depth probed. Any inspection which... and is loaded in such a manner that it is possible to secure only door-probe or shallow-probe samples...
7 CFR 800.84 - Inspection of grain in land carriers, containers, and barges in single lots.
Code of Federal Regulations, 2012 CFR
2012-01-01
... each probe, the grain shall be sampled as thoroughly as possible with an approved probe. The grain in... show a statement, as specified in the instructions, indicating the depth probed. Any inspection which... and is loaded in such a manner that it is possible to secure only door-probe or shallow-probe samples...
7 CFR 800.84 - Inspection of grain in land carriers, containers, and barges in single lots.
Code of Federal Regulations, 2014 CFR
2014-01-01
... probe, the grain shall be sampled as thoroughly as possible with an approved probe. The grain in the... statement, as specified in the instructions, indicating the depth probed. Any inspection which is based on a... manner that it is possible to secure only door-probe or shallow-probe samples, the container shall be...
7 CFR 800.84 - Inspection of grain in land carriers, containers, and barges in single lots.
Code of Federal Regulations, 2013 CFR
2013-01-01
... each probe, the grain shall be sampled as thoroughly as possible with an approved probe. The grain in... show a statement, as specified in the instructions, indicating the depth probed. Any inspection which... and is loaded in such a manner that it is possible to secure only door-probe or shallow-probe samples...
Eickholz, Peter; Siegelin, Yasemin; Scharf, Susanne; Schacher, Beate; Oremek, Gerhard M; Sauer-Eppel, Hildegund; Schubert, Ralf; Wohlfeil, Martin
2013-04-01
Assessment of the effect of non-surgical periodontal therapy (SRP) on serum inflammatory parameters in patients with untreated aggressive (AgP) and chronic (ChP) periodontitis. Overall, 31 ChP and 29 AgP were examined clinically prior to and 12 weeks after SRP (subgingival scaling of all pockets within 2 days) with systemic antibiotics for patients positive for Aggregatibacter actinomycetemcomitans (14 AgP, 9 ChP). Blood was sampled prior to, one day, 6, and 12 weeks after the first SRP visit. Serum elastase, C-reactive protein (CRP), lipopolysaccharide-binding protein (LBP), interleukin (IL) 6, 8, and leukocyte counts were assessed. At baseline, serum elastase, CRP, and LBP were significantly (p < 0.01) higher in AgP than ChP. Serum elastase, CRP, LBP, and IL-6 were significantly (p < 0.001) elevated one day after scaling in both groups. Both groups showed significant clinical improvement (p < 0.001). A significant difference was observed regarding change of serum elastase 12 weeks after SRP between AgP and ChP (p = 0.015). Multiple regression analysis revealed AgP, African origin, and bleeding on probing to be associated with more pronounced elastase reduction. CRP reduction was associated with African origin, systemic antibiotics, and baseline probing pocket depth. SRP results in serum elastase reduction in AgP but not in ChP. © 2013 John Wiley & Sons A/S.
USDA-ARS?s Scientific Manuscript database
Vera et al. (2009) compared estimates of soil profile water content (mm) to a depth of 0.8 m made with the neutron moisture meter (NMM) and a multi-depth capacitance probe (MDCP), using measurements replicated in four drainage lysimeters (5 m x 5 m x 1.5-m deep). The NMM estimates of water content w...
Garg, Surbhi; Arora, Sachit Anand; Chhina, Shivjot; Singh, Padam
2017-01-01
Background: Gingival recession involves both soft tissue and hard tissue loss. In this evolutionary era of dentistry, newer techniques have evolved for complete coverage of isolated recession defects. Since 2012, vestibular incision subperiosteal tunnel access (VISTA) technique was used with various regenerative membranes to treat multiple recession defects (MRDs). Platelet-rich fibrin (PRF) membrane, a pool of growth factors but have any added advantage to recession coverage techniques is controversial. Thus, in this case series, we compare the effect of VISTA with or without PRF-membrane for the treatment of Classes I and III MRDs. Subjects and Methods: Four patients between of age 30 and 40 years (two patients having bilateral Class I and another two having bilateral Class III MRDs) were selected from the Department of Periodontics, ITS Dental College, Greater Noida and designated as Case I–IV simultaneously. Recession defects at antagonist sites in each patient were corrected by VISTA approach with or without PRF-membrane. Recorded clinical parameters included recession depth, recession width, pocket probing depth, and clinical attachment level (CAL) at baseline and 6 months postoperatively. Results: Patients having Class I recession defects showed almost complete root coverage with VISTA technique alone and reflected no added advantage of PRF-membrane. However, patients with Class III recession defects treated with VISTA + PRF-membrane showed more reduction in recession depth and gain in CAL as compared to sites treated with VISTA only. Conclusion: VISTA alone is a convenient technique for treatment of Class I MRDs. Addition of PRF-membrane for Class III recession defects give better outcome in term of reduction of recession depth and gain in CAL 6 month postoperatively. PMID:29042736
Long-term effect of tetracycline fibers on recurrent lesions in periodontal maintenance patients.
Corsair, A
1994-01-01
Thirty-one patients with chronic adult periodontitis participated in this long-term private practice study. Sixty-one sites with moderate (4-6 mm, n = 21) or deep (> or = 7 mm, n = 40) periodontal pockets and bleeding on probing were treated with an antibiotic-releasing fiber, Actisite (Periodontal Therapeutic System) (tetracycline hydrochloride). Scaling/root planing (SRP) was performed on all teeth 3 weeks before start of the study, and on most teeth immediately before fiber insertion. Monolithic fibers loaded with 25% tetracycline hydrochloride were inserted in periodontal pockets, where they were retained for a mean of 6.7 days, at which point they were removed. Patients were evaluated at 1, 3, and 6 months after treatment; subgroups were also evaluated at normalized 12-month (10 patients, 20 sites) and 24-month (13 patients, 20 sites) time points. Sites showed a mean probing depth reduction of 2.5 mm at 6 months, and 2.2 mm at 24 months, with the deepest sites showing the greatest reduction. Bleeding on probing was 100% at baseline, 34% at 3 months, and 50% at 6 months. Attachment gains in 18 patients (25 sites) were 2.4 mm at 1 month, 3.0 mm at 3 months, and 2.5 mm at 6 months. Fibers were well tolerated; no adverse effects from treatment were noted. These results indicate that use of tetracycline fiber plus SRP clearly reduced the clinical signs of periodontal disease and maintained or improved attachment for up to 24 months in sites previously refractory to treatment.
[Periodontitis from a systemic point of view: an advanced treatment concept with Padma Circosan].
Müller, Wolfgang
2013-01-01
Periodontitis is a chronic inflammation of the periodontium, with the formation of bacterial biofilms in the gingival pockets. The inflammatory cascade is difficult to interrupt and leads to a destruction of the periodontium and bone loss as well as to a systemic inflammatory state. This may promote diseases such as atherosclerosis, diabetes, endothelial dysfunction, and cardiovascular events. An integrative treatment approach includes not only the treatment of the periodontitis (in our practice, following the Würzburg concept) but also an anti-inflammatory therapy. The evaluation of data from 10 patients with chronic periodontitis who were additionally treated with the Tibetan Medicine Padma Circosan showed, after 6 months, a significant reduction in the sites with a probing depth of ≥ 4 mm (-64%) and in bleeding on probing (-87%). Due to its anti-inflammatory, antioxidant, and circulation-promoting effects, Padma Circosan is well suited for the additive treatment of periodontitis in an integrative therapy concept.
Iha, Kosaku; Suzuki, Nao; Yoneda, Masahiro; Takeshita, Toru; Hirofuji, Takao
2013-10-01
The aim of the study was to evaluate the effect of mouth cleaning with hinokitiol-containing gel on oral malodor. An open-label, randomized, controlled trial was conducted to assess oral malodor and clinical parameters related to oral malodor before and after mouth cleaning with hinokitiol-containing gel (n = 9) or with gel not including hinokitiol (n = 9). Mouth cleaning included the teeth, gingiva, and tongue and was carried out 3 times per day for 4 weeks. Organoleptic test (OLT) scores (P = .021), levels of hydrogen sulfide (P = .008) and methyl mercaptan (P = .020), frequency of bleeding on probing, average probing pocket depth, and plaque index significantly improved in the group using hinokitiol. In contrast, only the OLT score (P = .031) significantly improved in the control group after the treatment regimen. Mouth cleaning with hinokitiol-containing gel may be effective for reduction of oral malodor. Copyright © 2013 Elsevier Inc. All rights reserved.
Chapple, Iain L C; Milward, Michael R; Ling-Mountford, Nicola; Weston, Paul; Carter, Kevin; Askey, Keeley; Dallal, Gerard E; De Spirt, Silke; Sies, Helmut; Patel, Dina; Matthews, John B
2012-01-01
Aim A double-blind randomized controlled trial to determine whether dietary supplementation with fruit/vegetable/berry juice powder concentrates, simultaneously with non-surgical periodontal therapy, improved 2-month treatment outcomes. Methods Volunteers with chronic periodontitis were randomly assigned to one of three groups: fruit/vegetable (FV), fruit/vegetable/berry (FVB) or placebo. Supplements were taken daily during non-surgical debridement and maintenance and outcomes assessed at 2, 5 and 8 months after completion. Primary outcomes were mean probing pocket depth (PPD), clinical attachment gain, % sites bleeding on probing (% BOP) at 2 months. Adherence and plasma β-carotene were determined. Results Sixty-one nutritionally replete (by serum biochemistry) volunteers enrolled and 60 (n = 20 per arm) completed the 2-month review. Clinical outcomes improved in all groups at 2 months, with additional improvement in PPD versus placebo for FV (p < 0.03). Gingival crevicular fluid volumes diminished more in supplement groups than placebo (FVB; p < 0.05) at 2 months, but not at later times. The % BOP (5 months) and cumulative plaque scores (8 months) were lowered more in the FV group (p < 0.05). Conclusions Adjunctive juice powder concentrates appear to improve initial pocket depth reductions in nutritionally replete patients, where plasma micronutrient bioavailability is attainable. Definitive multicentre studies in untreated and treated patients are required to ascertain the clinical significance of such changes. PMID:22093005
Towards next generation time-domain diffuse optics devices
NASA Astrophysics Data System (ADS)
Dalla Mora, Alberto; Contini, Davide; Arridge, Simon R.; Martelli, Fabrizio; Tosi, Alberto; Boso, Gianluca; Farina, Andrea; Durduran, Turgut; Martinenghi, Edoardo; Torricelli, Alessandro; Pifferi, Antonio
2015-03-01
Diffuse Optics is growing in terms of applications ranging from e.g. oximetry, to mammography, molecular imaging, quality assessment of food and pharmaceuticals, wood optics, physics of random media. Time-domain (TD) approaches, although appealing in terms of quantitation and depth sensibility, are presently limited to large fiber-based systems, with limited number of source-detector pairs. We present a miniaturized TD source-detector probe embedding integrated laser sources and single-photon detectors. Some electronics are still external (e.g. power supply, pulse generators, timing electronics), yet full integration on-board using already proven technologies is feasible. The novel devices were successfully validated on heterogeneous phantoms showing performances comparable to large state-of-the-art TD rack-based systems. With an investigation based on simulations we provide numerical evidence that the possibility to stack many TD compact source-detector pairs in a dense, null source-detector distance arrangement could yield on the brain cortex about 1 decade higher contrast as compared to a continuous wave (CW) approach. Further, a 3-fold increase in the maximum depth (down to 6 cm) is estimated, opening accessibility to new organs such as the lung or the heart. Finally, these new technologies show the way towards compact and wearable TD probes with orders of magnitude reduction in size and cost, for a widespread use of TD devices in real life.
Model studies of surface noise interference in ground-probing radar
NASA Astrophysics Data System (ADS)
Arcone, S. A.; Delaney, A. J.
1985-11-01
Ground-probing radar can be an effective tool for exploring the top 10 to 20 m of ground, especially in cold regions where the freezing of water decreases signal absorption. However, the large electrical variability of the surface, combined with the short wavelengths used, can often cause severe ground clutter that can mask a desired, deeper return. In this study a model facility was constructed consisting of a metallic reflector covered by sand. Troughs of saturated sand were emplaced at the surface to carry surface electrical properties and to act as a noise source to interfere with the bottom reflections. Antenna polarization and height, and signal stacking in both static (antennas stationary) and dynamic (antennas moving) modes were then investigated as methods for reducing the surface clutter. Polarization parallel to the profile direction (perpendicular to the troughs' axes) gave profiles superior to the perpendicular case because of the dimensional sensitivity of the antenna radiation. Dynamic stacking greatly improved the signal-to-noise ratio because noise sources were averaged as the antennas moved, while the desired reflector, buried at constant depth, was enhanced. Raising the antennas above the surface also reduced noise because the surface area over which reflections were integrated increased. All three noise reduction techniques could be effective in surveys for reflectors at nearly constant depth such as groundwater tables or ice/water interfaces.
Herrera, D; Roldán, S; O'Connor, A; Sanz, M
2000-06-01
The aim of this short-term open parallel longitudinal clinical study was to compare the clinical and microbiological efficacy of 2 different antibiotic regimes in the treatment of acute periodontal abscesses. After patient selection, a clinical examination was carried out recording the following variables: pain, edema, redness, swelling, bleeding on probing, suppuration, tooth mobility, lymphadenopathy, and probing pocket depth. Microbiological samples were taken from the lesion and the patient was randomly assigned to one of two antibiotic regimes: azithromycin or amoxicillin/clavulanate. Clinical variables were recorded, and microbiological samples were taken, at 3-5 days, 10-12 days and 30 days. Additional mechanical treatment (debridement and scaling) was performed in the third visit (10-12 days). Blood and urine samples were collected at baseline and after 10-12 days. Microbiological samples were processed by anaerobic culturing, and isolated periodontal pathogens were tested for antibiotic susceptibility by means of the spiral gradient endpoint methodology. 15 patients took azithromycin, and 14 amoxicillin/clavulanate. Subjective clinical variables demonstrated statistically significant improvements with both antibiotic regimes, which lasted for at least 1 month (p<0.01). Objective clinical variables also showed clear improvements, being statistically significant after 30 days with probing pocket depth in the azithromycin group (p<0.01). Microbiologically, short-term reductions were detected with both antibiotics, however fast recolonization occurred after the third visit. No significant differences were found between both treatment regimes. Antibiotic susceptibilities demonstrated no resistances for amoxicillin/clavulanate, while 2-3 strains of each studied pathogen were resistant to azithromycin. However, both antibiotic regimes were effective in the short-term treatment of periodontal abscesses in periodontitis patients.
Kour, Amandeep; Kumar, Ashish; Puri, Komal; Khatri, Manish; Bansal, Mansi; Gupta, Geeti
2016-01-01
To compare and evaluate the intra- and inter-examiner efficacy and reproducibility of the first-generation manual (Williams) probe and the third-generation Florida probe in terms of measuring pocket probing depth (PD) and clinical attachment level (CAL). Forty subjects/4000 sites were included in this comparative, cross-sectional study. Group- and site-wise categorizations were done. Based on gingival index, PD, and CAL, patients were divided into four groups, i.e., periodontally healthy, gingivitis, mild to moderate periodontitis, and severe periodontitis. Further, based on these parameters, a total of 4000 sites, with 1000 sites in each category randomly selected from these 40 patients, were taken. Full mouth PD and CAL measurements were recorded with two probes, by Examiner 1 and on Ramfjord teeth by Examiner 2. Full mouth and Ramfjord teeth group- and site-wise PD obtained with the manual probe by both the examiners were statistically significantly deeper than that obtained with the Florida probe. The full mouth and Ramfjord teeth mean CAL measurement by Florida probe was higher as compared to manual probe in mild to moderate periodontitis group and sites, whereas in severe periodontitis group and sites, manual probe recorded higher CAL as compared to Florida probe. Mean PD and CAL measurements were deeper with the manual probe as compared to the Florida probe in all the groups and sites, except for the mild-moderate periodontitis group and sites where the CAL measurements with the manual probe were less than the Florida probe. Manual probe was more reproducible and showed less interexaminer variability as compared to the Florida probe.
Dong, Guo-Chung; Chiu, Li-Chen; Ting, Chien-Kun; Hsu, Jia-Ruei; Huang, Chih-Chung; Chang, Yin; Chen, Gin-Shin
2017-09-01
Ultrasound guidance for epidural block has improved clinical blind-trial problems but the design of present ultrasonic probes poses operating difficulty of ultrasound-guided catheterization, increasing the failure rate. The purpose of this study was to develop a novel ultrasonic probe to avoid needle contact with vertebral bone during epidural catheterization. The probe has a central circular passage for needle insertion. Two focused annular transducers are deployed around the passage for on-axis guidance. A 17-gauge insulated Tuohy needle containing the self-developed fiber-optic-modified stylet was inserted into the back of the anesthetized pig, in the lumbar region under the guidance of our ultrasonic probe. The inner transducer of the probe detected the shallow echo signals of the peak-peak amplitude of 2.8 V over L3 at the depth of 2.4 cm, and the amplitude was decreased to 0.8 V directly over the L3 to L4 interspace. The outer transducer could detect the echoes from the deeper bone at the depth of 4.5 cm, which did not appear for the inner transducer. The operator tilted the probe slightly in left-right and cranial-caudal directions until the echoes at the depth of 4.5 cm disappeared, and the epidural needle was inserted through the central passage of the probe. The needle was advanced and stopped when the epidural space was identified by optical technique. The needle passed without bone contact. Designs of the hollow probe for needle pass and dual transducers with different focal lengths for detection of shallow and deep vertebrae may benefit operation, bone/nonbone identification, and cost.
Detecting both melanoma depth and volume in vivo with a handheld photoacoustic probe
NASA Astrophysics Data System (ADS)
Zhou, Yong; Li, Guo; Zhu, Liren; Li, Chiye; Cornelius, Lynn A.; Wang, Lihong V.
2016-03-01
We applied a linear-array-based photoacoustic probe to detect the tumor depth and volume of melanin-containing melanoma in nude mice in vivo. We demonstrated the ability of this linear-array-based system to measure both the depth and volume of melanoma through phantom, ex vivo, and in vivo experiments. The volume detection ability also enables us to accurately calculate the rate of growth of the tumor, which is important in quantifying tumor activity. Our results show that this system can be used for clinical melanoma diagnosis and treatment at the bedside.
Depth Profilometry via Multiplexed Optical High-Coherence Interferometry
Kazemzadeh, Farnoud; Wong, Alexander; Behr, Bradford B.; Hajian, Arsen R.
2015-01-01
Depth Profilometry involves the measurement of the depth profile of objects, and has significant potential for various industrial applications that benefit from non-destructive sub-surface profiling such as defect detection, corrosion assessment, and dental assessment to name a few. In this study, we investigate the feasibility of depth profilometry using an Multiplexed Optical High-coherence Interferometry MOHI instrument. The MOHI instrument utilizes the spatial coherence of a laser and the interferometric properties of light to probe the reflectivity as a function of depth of a sample. The axial and lateral resolutions, as well as imaging depth, are decoupled in the MOHI instrument. The MOHI instrument is capable of multiplexing interferometric measurements into 480 one-dimensional interferograms at a location on the sample and is built with axial and lateral resolutions of 40 μm at a maximum imaging depth of 700 μm. Preliminary results, where a piece of sand-blasted aluminum, an NBK7 glass piece, and an optical phantom were successfully probed using the MOHI instrument to produce depth profiles, demonstrate the feasibility of such an instrument for performing depth profilometry. PMID:25803289
Depth profilometry via multiplexed optical high-coherence interferometry.
Kazemzadeh, Farnoud; Wong, Alexander; Behr, Bradford B; Hajian, Arsen R
2015-01-01
Depth Profilometry involves the measurement of the depth profile of objects, and has significant potential for various industrial applications that benefit from non-destructive sub-surface profiling such as defect detection, corrosion assessment, and dental assessment to name a few. In this study, we investigate the feasibility of depth profilometry using an Multiplexed Optical High-coherence Interferometry MOHI instrument. The MOHI instrument utilizes the spatial coherence of a laser and the interferometric properties of light to probe the reflectivity as a function of depth of a sample. The axial and lateral resolutions, as well as imaging depth, are decoupled in the MOHI instrument. The MOHI instrument is capable of multiplexing interferometric measurements into 480 one-dimensional interferograms at a location on the sample and is built with axial and lateral resolutions of 40 μm at a maximum imaging depth of 700 μm. Preliminary results, where a piece of sand-blasted aluminum, an NBK7 glass piece, and an optical phantom were successfully probed using the MOHI instrument to produce depth profiles, demonstrate the feasibility of such an instrument for performing depth profilometry.
Comparison of nine methods to estimate ear-canal stimulus levels
Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.
2014-01-01
The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079
Morphological Computation of Haptic Perception of a Controllable Stiffness Probe.
Sornkarn, Nantachai; Dasgupta, Prokar; Nanayakkara, Thrishantha
2016-01-01
When people are asked to palpate a novel soft object to discern its physical properties such as texture, elasticity, and even non-homogeneity, they not only regulate probing behaviors, but also the co-contraction level of antagonistic muscles to control the mechanical impedance of fingers. It is suspected that such behavior tries to enhance haptic perception by regulating the function of mechanoreceptors at different depths of the fingertips and proprioceptive sensors such as tendon and spindle sensors located in muscles. In this paper, we designed and fabricated a novel two-degree of freedom variable stiffness indentation probe to investigate whether the regulation of internal stiffness, indentation, and probe sweeping velocity (PSV) variables affect the accuracy of the depth estimation of stiff inclusions in an artificial silicon phantom using information gain metrics. Our experimental results provide new insights into not only the biological phenomena of haptic perception but also new opportunities to design and control soft robotic probes.
NASA Astrophysics Data System (ADS)
Viator, John A.; Paltauf, Guenther; Jacques, Steven L.; Prahl, Scott A.
2001-06-01
An endoscopic photoacoustic probe is designed and tested for use in PDT treatment of esophageal cancer. The probe, measuring less than 2.5 mm in diameter, was designed to fit within the lumen of an endoscope that will be inserted into an esophagus after PDT. PDT treatment results in a blanched, necrotic layer of cancerous tissue over a healthy, deeper layer of perfused tissue. The photoacoustic probe was designed to use acoustic propagation time to determine the thickness of the blanched surface of the esophagus, which corresponds to treatment depth. A side-firing 600 micrometers fiber delivered 532 nm laser light to induce acoustic waves in the perfused layer of the esophagus beneath the blanched (treated) layer. A PVDF transducer detected the induced acoustic waves and transmitted the signal to an oscilloscope. The probe was tested on clear and turbid tissue phantom layers over an optically absorbing dye solution.
Stella, Paulo Eduardo Melo; Falci, Saulo Gabriel Moreira; Oliveira de Medeiros, Lorrayne Estéfane; Douglas-de-Oliveira, Dhelfeson Willya; Gonçalves, Patricia Furtado; Flecha, Olga Dumont; Dos Santos, Cássio Roberto Rocha
2017-01-01
The aim of the present study was to assess the periodontal condition and sensitivity of second mandibular molars after the extraction of the adjacent third molar, while also assessing the quality of life of the patients. Twenty-three healthy patients were assessed in terms of probing depth, gingival height, gingival thickness, dental sensitivity, plaque index and bleeding on probing (adjacent second mandibular molar), before the surgical procedure, as well as 60 and 180 days after the surgery. The following data were also recorded and measured: the position and size of the impacted teeth; the size of the alveoli after surgery and the quality of life of the patient. Significant differences were found for probing depth and gingival height before and after 180 days. The plaque index increased significantly after surgery ( P = 0.004), as did bleeding on probing. No significant difference was found for the quality of life. The size of the third molar extracted was correlated with bleeding on probing 180 days after the surgery. An improvement was noted in the periodontal condition of the second mandibular molars after the extraction, based on the assessments of probing depth and gingival height. The position of the third molar affected the periodontal condition of the second mandibular molar. No alterations were recorded for dental sensitivity or the quality of life after the extraction.
Stella, Paulo Eduardo Melo; Falci, Saulo Gabriel Moreira; Oliveira de Medeiros, Lorrayne Estéfane; Douglas-de-Oliveira, Dhelfeson Willya; Gonçalves, Patricia Furtado; Flecha, Olga Dumont; Dos Santos, Cássio Roberto Rocha
2017-01-01
Aim: The aim of the present study was to assess the periodontal condition and sensitivity of second mandibular molars after the extraction of the adjacent third molar, while also assessing the quality of life of the patients. Materials and Methods: Twenty-three healthy patients were assessed in terms of probing depth, gingival height, gingival thickness, dental sensitivity, plaque index and bleeding on probing (adjacent second mandibular molar), before the surgical procedure, as well as 60 and 180 days after the surgery. The following data were also recorded and measured: the position and size of the impacted teeth; the size of the alveoli after surgery and the quality of life of the patient. Results: Significant differences were found for probing depth and gingival height before and after 180 days. The plaque index increased significantly after surgery (P = 0.004), as did bleeding on probing. No significant difference was found for the quality of life. The size of the third molar extracted was correlated with bleeding on probing 180 days after the surgery. Conclusion: An improvement was noted in the periodontal condition of the second mandibular molars after the extraction, based on the assessments of probing depth and gingival height. The position of the third molar affected the periodontal condition of the second mandibular molar. No alterations were recorded for dental sensitivity or the quality of life after the extraction. PMID:29456302
NASA Astrophysics Data System (ADS)
Nammi, Srinagalakshmi; Vasa, Nilesh J.; Gurusamy, Balaganesan; Mathur, Anil C.
2017-09-01
A plasma shielding phenomenon and its influence on micromachining is studied experimentally and theoretically for laser wavelengths of 355 nm, 532 nm and 1064 nm. A time resolved pump-probe technique is proposed and demonstrated by splitting a single nanosecond Nd3+:YAG laser into an ablation laser (pump laser) and a probe laser to understand the influence of plasma shielding on laser ablation of copper (Cu) clad on polyimide thin films. The proposed nanosecond pump-probe technique allows simultaneous measurement of the absorption characteristics of plasma produced during Cu film ablation by the pump laser. Experimental measurements of the probe intensity distinctly show that the absorption by the ablated plume increases with increase in the pump intensity, as a result of plasma shielding. Theoretical estimation of the intensity of the transmitted pump beam based on the thermo-temporal modeling is in qualitative agreement with the pump-probe based experimental measurements. The theoretical estimate of the depth attained for a single pulse with high pump intensity value on a Cu thin film is limited by the plasma shielding of the incident laser beam, similar to that observed experimentally. Further, the depth of micro-channels produced shows a similar trend for all three wavelengths, however, the channel depth achieved is lesser at the wavelength of 1064 nm.
Lin, Huiyun; Zhang, Rongxiao; Gunn, Jason R; Esipova, Tatiana V; Vinogradov, Sergei; Gladstone, David J; Jarvis, Lesley A; Pogue, Brian W
2016-05-21
Ionizing radiation delivered by a medical linear accelerator (LINAC) generates Cherenkov emission within the treated tissue. A fraction of this light, in the 600-900 nm wavelength region, propagates through centimeters of tissue and can be used to excite optical probes in vivo, enabling molecular sensing of tissue analytes. The success of isolating the emission signal from this Cherenkov excitation background is dependent on key factors such as: (i) the Stokes shift of the probe spectra; (ii) the excited state lifetime; (iii) the probe concentration; (iv) the depth below the tissue surface; and (v) the radiation dose used. Previous studies have exclusively focused on imaging phosphorescent dyes, rather than fluorescent dyes. However there are only a few biologically important phosphorescent dyes and yet in comparison there are thousands of biologically relevant fluorescent dyes. So in this study the focus was a study of efficacy of Cherenkov-excited luminescence using fluorescent commercial near-infrared probes, IRDye 680RD, IRDye 700DX, and IRDye 800CW, and comparing them to the well characterized phosphorescent probe Oxyphor PtG4, an oxygen sensitive dye. Each probe was excited by Cherenkov light from a 6 MV external radiation beam, and measured in continuous wave or time-gated modes. The detection was performed by spectrally resolving the luminescence signals, and measuring them with spectrometer-based separation on an ICCD detector. The results demonstrate that IRDye 700DX and PtG4 allowed for the maximal signal to noise ratio. In the case of the phosphorescent probe, PtG4, with emission decays on the microsecond (μs) time scale, time-gated acquisition was possible, and it allowed for higher efficacy in terms of the probe concentration and detection depth. Phantoms containing the probe at 5 mm depth could be detected at concentrations down to the nanoMolar range, and at depths into the tissue simulating phantom near 3 cm. In vivo studies showed that 5 nmol of dye was readily detected with radiation doses less than 5 cGy. Since concentration, radiation dose and depth each contribute to the level of the detected signal, it may be possible to improve any of these parameters at expense of the others. This paradigm of nanoMolar sensitivity for optical reporters in vivo introduces the concept of molecular sensing of tumors during therapy or diagnostically with biologically relevant concentrations of fluorescent reporters.
NASA Astrophysics Data System (ADS)
Lin, Huiyun; Zhang, Rongxiao; Gunn, Jason R.; Esipova, Tatiana V.; Vinogradov, Sergei; Gladstone, David J.; Jarvis, Lesley A.; Pogue, Brian W.
2016-05-01
Ionizing radiation delivered by a medical linear accelerator (LINAC) generates Cherenkov emission within the treated tissue. A fraction of this light, in the 600-900 nm wavelength region, propagates through centimeters of tissue and can be used to excite optical probes in vivo, enabling molecular sensing of tissue analytes. The success of isolating the emission signal from this Cherenkov excitation background is dependent on key factors such as: (i) the Stokes shift of the probe spectra; (ii) the excited state lifetime; (iii) the probe concentration; (iv) the depth below the tissue surface; and (v) the radiation dose used. Previous studies have exclusively focused on imaging phosphorescent dyes, rather than fluorescent dyes. However there are only a few biologically important phosphorescent dyes and yet in comparison there are thousands of biologically relevant fluorescent dyes. So in this study the focus was a study of efficacy of Cherenkov-excited luminescence using fluorescent commercial near-infrared probes, IRDye 680RD, IRDye 700DX, and IRDye 800CW, and comparing them to the well characterized phosphorescent probe Oxyphor PtG4, an oxygen sensitive dye. Each probe was excited by Cherenkov light from a 6 MV external radiation beam, and measured in continuous wave or time-gated modes. The detection was performed by spectrally resolving the luminescence signals, and measuring them with spectrometer-based separation on an ICCD detector. The results demonstrate that IRDye 700DX and PtG4 allowed for the maximal signal to noise ratio. In the case of the phosphorescent probe, PtG4, with emission decays on the microsecond (μs) time scale, time-gated acquisition was possible, and it allowed for higher efficacy in terms of the probe concentration and detection depth. Phantoms containing the probe at 5 mm depth could be detected at concentrations down to the nanoMolar range, and at depths into the tissue simulating phantom near 3 cm. In vivo studies showed that 5 nmol of dye was readily detected with radiation doses less than 5 cGy. Since concentration, radiation dose and depth each contribute to the level of the detected signal, it may be possible to improve any of these parameters at expense of the others. This paradigm of nanoMolar sensitivity for optical reporters in vivo introduces the concept of molecular sensing of tumors during therapy or diagnostically with biologically relevant concentrations of fluorescent reporters.
Mapping snow depth within a tundra ecosystem using multiscale observations and Bayesian methods
Wainwright, Haruko M.; Liljedahl, Anna K.; Dafflon, Baptiste; ...
2017-04-03
This paper compares and integrates different strategies to characterize the variability of end-of-winter snow depth and its relationship to topography in ice-wedge polygon tundra of Arctic Alaska. Snow depth was measured using in situ snow depth probes and estimated using ground-penetrating radar (GPR) surveys and the photogrammetric detection and ranging (phodar) technique with an unmanned aerial system (UAS). We found that GPR data provided high-precision estimates of snow depth (RMSE=2.9cm), with a spatial sampling of 10cm along transects. Phodar-based approaches provided snow depth estimates in a less laborious manner compared to GPR and probing, while yielding a high precision (RMSE=6.0cm) andmore » a fine spatial sampling (4cm×4cm). We then investigated the spatial variability of snow depth and its correlation to micro- and macrotopography using the snow-free lidar digital elevation map (DEM) and the wavelet approach. We found that the end-of-winter snow depth was highly variable over short (several meter) distances, and the variability was correlated with microtopography. Microtopographic lows (i.e., troughs and centers of low-centered polygons) were filled in with snow, which resulted in a smooth and even snow surface following macrotopography. We developed and implemented a Bayesian approach to integrate the snow-free lidar DEM and multiscale measurements (probe and GPR) as well as the topographic correlation for estimating snow depth over the landscape. Our approach led to high-precision estimates of snow depth (RMSE=6.0cm), at 0.5m resolution and over the lidar domain (750m×700m).« less
Mapping snow depth within a tundra ecosystem using multiscale observations and Bayesian methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wainwright, Haruko M.; Liljedahl, Anna K.; Dafflon, Baptiste
This paper compares and integrates different strategies to characterize the variability of end-of-winter snow depth and its relationship to topography in ice-wedge polygon tundra of Arctic Alaska. Snow depth was measured using in situ snow depth probes and estimated using ground-penetrating radar (GPR) surveys and the photogrammetric detection and ranging (phodar) technique with an unmanned aerial system (UAS). We found that GPR data provided high-precision estimates of snow depth (RMSE=2.9cm), with a spatial sampling of 10cm along transects. Phodar-based approaches provided snow depth estimates in a less laborious manner compared to GPR and probing, while yielding a high precision (RMSE=6.0cm) andmore » a fine spatial sampling (4cm×4cm). We then investigated the spatial variability of snow depth and its correlation to micro- and macrotopography using the snow-free lidar digital elevation map (DEM) and the wavelet approach. We found that the end-of-winter snow depth was highly variable over short (several meter) distances, and the variability was correlated with microtopography. Microtopographic lows (i.e., troughs and centers of low-centered polygons) were filled in with snow, which resulted in a smooth and even snow surface following macrotopography. We developed and implemented a Bayesian approach to integrate the snow-free lidar DEM and multiscale measurements (probe and GPR) as well as the topographic correlation for estimating snow depth over the landscape. Our approach led to high-precision estimates of snow depth (RMSE=6.0cm), at 0.5m resolution and over the lidar domain (750m×700m).« less
NASA Astrophysics Data System (ADS)
Canavesi, Cristina; Cogliati, Andrea; Hayes, Adam; Tankam, Patrice; Santhanam, Anand; Rolland, Jannick P.
2017-02-01
Real-time volumetric high-definition wide-field-of-view in-vivo cellular imaging requires micron-scale resolution in 3D. Compactness of the handheld device and distortion-free images with cellular resolution are also critically required for onsite use in clinical applications. By integrating a custom liquid lens-based microscope and a dual-axis MEMS scanner in a compact handheld probe, Gabor-domain optical coherence microscopy (GD-OCM) breaks the lateral resolution limit of optical coherence tomography through depth, overcoming the tradeoff between numerical aperture and depth of focus, enabling advances in biotechnology. Furthermore, distortion-free imaging with no post-processing is achieved with a compact, lightweight handheld MEMS scanner that obtained a 12-fold reduction in volume and 17-fold reduction in weight over a previous dual-mirror galvanometer-based scanner. Approaching the holy grail of medical imaging - noninvasive real-time imaging with histologic resolution - GD-OCM demonstrates invariant resolution of 2 μm throughout a volume of 1 x 1 x 0.6 mm3, acquired and visualized in less than 2 minutes with parallel processing on graphics processing units. Results on the metrology of manufactured materials and imaging of human tissue with GD-OCM are presented.
Nart, José; de Tapia, Beatriz; Pujol, Àngels; Pascual, Andrés; Valles, Cristina
2017-12-24
To assess the clinical and radiographic outcomes of the regenerative treatment of peri-implantitis using a vancomycin and tobramycin impregnated allograft (VTA) after a 12-month period. Thirteen consecutive patients who required a regenerative treatment of peri-implantitis were recruited. For the 17 implant sites, a flap was raised, and after mechanical and chemical implant decontamination, a vancomycin and tobramycin impregnated allograft was placed in the defect and then covered with a collagen membrane. Soft tissues were sutured allowing a non-submerged healing. Clinical and radiographic variables were evaluated at baseline and at 12 months after treatment. No signs of continuous bone loss were observed and no implant was lost, yielding a 100% survival rate. All patient's clinical examination at 12 months revealed peri-implant health showing absence of suppuration and a statistically significant reduction in terms of bleeding on probing scores (70.6%, P = 0.001). Initial probing pocket depth (7.88 ± 1.22 mm) was significantly reduced at 12 months healing, a mean reduction of 4.23 ± 1.47 mm (P = 0.001) was achieved. The mean radiological infrabony defect at baseline reached 4.33 ± 1.62 mm, and was significantly reduced up to 0.56 ± 0.88 mm, which represents an 86.99 ± 18.2% bone fill from the original infrabony defect. Within the limits of the study, the application of VTA with a collagen membrane yielded positive outcomes in terms of radiographic bone fill, pocket depth reduction, and attachment gain after a 12-month period. Thus, VTA plus a collagen membrane seem to be suitable for the regenerative treatment of peri-implantitis. The use of locally delivered antibiotic together with the bone graft may reduce the undesirable effects related to the systemic administration and the risk of resistances. In the light of the results obtained, these grafting materials might offer new treatment strategies in the surgical regenerative treatment of peri-implantitis.
Euzebio Alves, Vanessa Tubero; de Andrade, Ana Karina Pinto; Toaliar, Janaita Maria; Conde, Marina Clemente; Zezell, Denise Maria; Cai, Silvana; Pannuti, Claudio Mendes; De Micheli, Giorgio
2013-01-01
This randomized split-mouth clinical trial was designed to evaluate the efficacy of scaling and root planing associated to the high-intensity diode laser on periodontal therapy by means of clinical parameters and microbial reduction. A total of 36 chronic periodontitis subjects, of both genders, were selected. One pair of contralateral single-rooted teeth with pocket depth >5 mm was chosen from each subject. All patients received non-surgical periodontal treatment, after which the experimental teeth were designated to either test or control groups. Both teeth received scaling, root planing and coronal polishing (SRP) and teeth assigned to the test group (SRP + DL) were irradiated with the 808 ± 5 nm diode laser, for 20 s, in two isolated appointments, 1 week apart. The laser was used in the continuous mode, with 1.5 W and power density of 1,193.7 W/cm(2). Clinical and microbiological data were collected at baseline, 6 weeks and 6 months after therapy. There was a significant improvement of all the clinical parameters-clinical attachment level (CAL), probing depth (PD), plaque index (PI) and Bleeding on Probing (BOP)-for both groups (P < 0.001), with no statistical difference between them at the 6 weeks and the 6 months examinations. As for microbiological analysis, a significant reduction after 6 weeks (P > 0.05) was observed as far as colony forming units (CFU) is concerned, for both groups. As for black-pigmented bacteria, a significant reduction was observed in both groups after 6 months. However, the difference between test and control groups was not significant. There was no association between group and presence of Porphyromonas gingivalis, Prevotella intermedia and Aggregatibacter actinomycetemcomitans at any time of the study. After 6 months of evaluation, the high-intensity diode laser has not shown any additional benefits to the conventional periodontal treatment. The high intensity diode laser did not provide additional benefits to non-surgical periodontal treatment. More studies are necessary to prove the actual need of this type of laser in the periodontal clinical practice.
Ranjbari, Ardeshir; Gholami, Gholam Ali; Amid, Reza; Kadkhodazadeh, Mahdi; Youssefi, Navid; Mehdizadeh, Amir Reza; Aghaloo, Maryam
2016-01-01
Statement of the Problem Gingival recession has been considered as the most challenging issue in the field of periodontal plastic surgery. Purpose The purpose of this study was to evaluate the clinical efficacy of root coverage procedures by using partial thickness double pedicle graft and compare it with full thickness double pedicle graft. Materials and Method Eight patients, aged 15 to 58 years including 6 females and 2 males with 20 paired (mirror image) defects with class I and II gingival recession were randomly assigned into two groups. Clinical parameters such as recession depth, recession width, clinical attachment level, probing depth, and width of keratinized tissue were measured at the baseline and 6 months post-surgery. A mucosal double papillary flap was elevated and the respective root was thoroughly planed. The connective tissue graft was harvested from the palate, and then adapted over the root. The pedicle flap was secured over the connective tissue graft and sutured. The surgical technique was similar in the control group except for the prepared double pedicle graft which was full thickness. Results The mean root coverage was 88.14% (2.83 mm) in the test group and 85.7% (2.75 mm) in the control group. No statistical differences were found in the mean reduction of vertical recession, width of recession, or probing depth between the test and control groups. In both procedures, the width of keratinized tissue increased after three months and the difference between the two groups was not statistically significant in this respect. Conclusion Connective tissue with partial and full thickness double pedicle grafts can be successfully used for treatment of marginal gingival recession. PMID:27602394
Singh, Sangeeta
2009-05-01
To evaluate the efficacy of platelet-rich plasma concentrate in the management of a cirumferential, infrabony defect associated with an endoperio lesion in a maxillary canine. A 45 year-old male patient with an endoperio lesion in the left maxillary canine was initially treated with endodontic therapy. Following the endodontic treatment, the circumferential, infrabony defect was treated using platelet-rich plasma and an alloplastic bone substitute. At the end of three months, there was a gain in the clinical attachment level and reduction in probing depth. Radiographic evidence showed that there was significant bony fill. The results were maintained at the time of recall nine months later.
Seismotectonics and Crustal Thickness of Northwest Mindoro, Philippines
NASA Astrophysics Data System (ADS)
Chen, P. F.; Olavere, E. A.; Lee, K. M.; Bautista, B.; Solidum, R., Jr.; Huang, B. S.
2015-12-01
Mindoro Island locates where the Palawan Continental Block (PCB) indented into the Philippine Mobile Belt (PMB) during the Early Miocene and where the Manila Trench terminates, having ceased convergence due to collision. On the transition from subduction to collision, Northwest Mindoro exhibits vigorous seismic activity and has been debated about its affiliation being PCB or PMB. Here, we use data from both the EHB and Global Centroid Moment Tensor catalogues to study the regional seismotectonics. We also deployed five broadband stations to probe the crustal thickness beneath NW Mindoro using receiver function analysis. Results show that, following the southeasterly reduction of convergence rates at the southern termination of the Manila Trench, the slab dipping angles steepen, were initiated at depth (~200 km) and propagate upwards. The horizontal distances of the trench and slab, as measured from the Wadati-Benioff zone at 200 km depth, also reduce in a southeasterly direction. Observations of intermediate-depth earthquakes that exhibit predominantly down-dip extensional stress patterns attest that the steepening of slab dipping angles is due to the negative buoyancy of the slab. Preliminary results of receiver function analysis suggest that the crustal thickness beneath NW Mindoro is about 40 km and is probably PCB affiliated.
Depth-sensitive optical spectroscopy for layered tissue measurements (Conference Presentation)
NASA Astrophysics Data System (ADS)
Liu, Wei; Yu, Xiaojun; Liu, Quan; Liu, Linbo; Ong, Yi Hong
2017-02-01
Disease diagnosis based on the visual inspection of the pathological presentations or symptoms on the epithelial tissue such as the skin are subjective and highly depend on the experience of the doctors. Vital diagnostic information for the accurate identification of diseases is usually located underneath the surface and its depth distribution is known to be related to disease progression. Although optical spectroscopic measurements are fast and non-invasive, the accurate retrieval of the depth-specific diagnostic information is complicated by the heterogeneous nature of epithelial tissues. The optical signal measured from a tissue is often the result of averaging from a large tissue volume that mixes information from the region of interest and the surrounding tissue region, especially from the overlaying layers. Our group has developed a series of techniques for depth sensitive optical measurements from such layered tissues. We will first review the earlier development of composite fiber-optic probe, in which the source-detector separation and the angles of source and detector fibers are varied to achieve depth sensitive measurements. Then the more recent development of non-contact axicon lens based probes for depth sensitive fluorescence measurements and the corresponding numerical methods for optimization will be introduced. Finally, the most recently developed snapshot axicon lens based probe that can measure Raman spectra from five different depths at the same time will be discussed. Results from tissue phantoms, ex vivo pork samples and in vivo fingernail measurements will be presented, which indicates the great potential of depth sensitive optical spectroscopy for clinical tissue diagnosis.
Renvert, Stefan; Lindahl, Christel; Roos-Jansåker, Ann-Marie; Lessem, Jan
2009-06-01
Periodontal disease is the most common multifactorial disease, afflicting a very large proportion of the adult population. Periodontal disease secondarily causes increases in the serum levels of C-reactive protein (CRP) and other markers of inflammation. An increased level of CRP reflects an increased risk for cardiovascular disease. The aim of the current randomized clinical trial was to evaluate the short-term effect of a combination of dipyridamole and prednisolone (CRx-102) on the levels of high-sensitivity (hs)-CRP, proinflammatory markers in blood, and clinical signs of periodontal disease. Fifty-seven patients with >/=10 pockets with probing depths >/=5 mm were randomized into two groups in this masked single-center placebo-controlled study: CRx-102 (n = 28) and placebo (n = 29). hs-CRP levels, inflammatory markers (interleukin [IL]-6, -1beta, -8, and -12, tumor necrosis factor-alpha, and interferon-gamma [IFN-gamma]), bleeding on probing (BOP), and changes in probing depths were evaluated. The subjects received mechanical non-surgical therapy after 42 days, and the study was completed after 49 days. At day 42, the differences in the hs-CRP, IFN-gamma, and IL-6 levels between the two groups were statistically significant (P <0.05), whereas no difference was found for the other inflammatory markers. There was no change in probing depth or BOP between the two groups. The administration of CRx-102 resulted in significant decreases in hs-CRP, IFN-gamma, and IL-6, but it did not significantly change BOP or probing depths.
Induction of Intracellular Reductive Stress with a Photoactivatable Phosphine Probe.
Tirla, Alina; Rivera-Fuentes, Pablo
2018-04-25
Reductive stress is a condition present in cells that have an increased concentration of reducing species, and it has been associated with a number of pathologies, such as neurodegenerative diseases and cancer. The tools available to study reductive stress lack both in selectivity and specific targeting and some of these shortcomings can be addressed by using photoactivatable compounds. We developed a photoactivatable phosphonium probe, which upon irradiation releases a fluorescent molecule and a trialkyphosphine. The probes can permeate through the plasma membrane and the photoreleased phosphine can induce intracellular reductive stress as proven by the detection of protein aggregates.
Berkowitz, Bruce A; Gorgis, Jawan; Patel, Ankit; Baameur, Faiza; Gurevich, Vsevolod V; Craft, Cheryl M; Kefalov, Vladimir J; Roberts, Robin
2015-02-01
Rod tetrameric arrestin 1 (tet-ARR1), stored in the outer nuclear layer/inner segments in the dark, modulates photoreceptor synaptic activity; light exposure stimulates a reduction via translocation to the outer segments for terminating G-protein coupled phototransduction signaling. Here, we test the hypothesis that intraretinal spin-lattice relaxation rate in the rotating frame (1/T1ρ), an endogenous MRI contrast mechanism, has high potential for evaluating rod tet-ARR1 and its reduction via translocation. Dark- and light-exposed mice (null for the ARR1 gene, overexpressing ARR1, diabetic, or wild type with or without treatment with Mn2+, a calcium channel probe) were studied using 1/T1ρ MRI. Immunohistochemistry and single-cell recordings of the retinas were also performed. In wild-type mice with or without treatment with Mn2+, 1/T1ρ of avascular outer retina (64% to 72% depth) was significantly (P < 0.05) greater in the dark than in the light; a significant (P < 0.05) but opposite pattern was noted in the inner retina (<50% depth). Light-evoked outer retina Δ1/T1ρ was absent in ARR1-null mice and supernormal in overexpressing mice. In diabetic mice, the outer retinal Δ1/T1ρ pattern suggested normal dark-to-light tet-ARR1 translocation and chromophore content, conclusions confirmed ex vivo. Light-stimulated Δ1/T1ρ in inner retina was linked to changes in blood volume. Our data support 1/T1ρ MRI for noninvasively assessing rod tet-ARR1 and its reduction via protein translocation, which can be combined with other metrics of retinal function in vivo. © FASEB.
Floating Potential Probe Langmuir Probe Data Reduction Results
NASA Technical Reports Server (NTRS)
Morton, Thomas L.; Minow, Joseph I.
2002-01-01
During its first five months of operations, the Langmuir Probe on the Floating Potential Probe (FPP) obtained data on ionospheric electron densities and temperatures in the ISS orbit. In this paper, the algorithms for data reduction are presented, and comparisons are made of FPP data with ground-based ionosonde and Incoherent Scattering Radar (ISR) results. Implications for ISS operations are detailed, and the need for a permanent FPP on ISS is examined.
Integrated RFA/OCT catheter for real-time guidance of cardiac RFA therapy (Conference Presentation)
NASA Astrophysics Data System (ADS)
Fu, Xiaoyong; Blumenthal, Colin; Dosluoglu, Deniz; Wang, Yves T.; Jenkins, Michael W.; Souza, Rakesh; Snyder, Christopher; Arruda, Mauricio; Rollins, Andrew M.
2016-03-01
Currently, cardiac radiofrequency ablation is guided by indirect signals. We demonstrate an integrated radiofrequency ablation (RFA) and optical coherence tomography (OCT) probe for directly monitoring of the RFA procedure with OCT images in real time. The integrated RFA/OCT probe is modified from a standard commercial RFA catheter, and a newly designed and fabricated miniature forward-viewing cone-scanning OCT probe is integrated into the modified probe. The OCT system is verified with the human finger images, and the results show the integrated RFA/OCT probe can acquire high quality OCT images. The radiofrequency energy delivering function of the integrated probe is verified by comparing the RFA lesion sizes with standard commercial RFA probe. For the standard commercial probe, the average width and depth of the 10 lesions were 3.5 mm and 1.8 mm respectively. For the integrated RFA/OCT probe, the average width and depth of the 10 lesions were 3.6 mm and 1.7 mm respectively. The lesions created by the two probes are indistinguishable in size. This demonstrates that our glass window in the integrated probe has little effect on the RF energy delivery. And the integrated probe is used to monitoring the cardiac RFA procedure in real time. The results show that the RFA lesion formation can be confirmed by the loss of birefringence in the heart tissue. The system can potentially in vivo image of the cardiac wall to aid RFA therapy for cardiac arrhythmias.
NASA Astrophysics Data System (ADS)
Puszka, Agathe; Di Sieno, Laura; Dalla Mora, Alberto; Pifferi, Antonio; Contini, Davide; Boso, Gianluca; Tosi, Alberto; Hervé, Lionel; Planat-Chrétien, Anne; Koenig, Anne; Dinten, Jean-Marc
2014-02-01
Fiber optic probes with a width limited to a few centimeters can enable diffuse optical tomography (DOT) in intern organs like the prostate or facilitate the measurements on extern organs like the breast or the brain. We have recently shown on 2D tomographic images that time-resolved measurements with a large dynamic range obtained with fast-gated single-photon avalanche diodes (SPADs) could push forward the imaged depth range in a diffusive medium at short source-detector separation compared with conventional non-gated approaches. In this work, we confirm these performances with the first 3D tomographic images reconstructed with such a setup and processed with the Mellin- Laplace transform. More precisely, we investigate the performance of hand-held probes with short interfiber distances in terms of spatial resolution and specifically demonstrate the interest of having a compact probe design featuring small source-detector separations. We compare the spatial resolution obtained with two probes having the same design but different scale factors, the first one featuring only interfiber distances of 15 mm and the second one, 10 mm. We evaluate experimentally the spatial resolution obtained with each probe on the setup with fast-gated SPADs for optical phantoms featuring two absorbing inclusions positioned at different depths and conclude on the potential of short source-detector separations for DOT.
Clean, Logistically Light Access to Explore the Closest Places on Earth to Europa and Enceladus
NASA Astrophysics Data System (ADS)
Winebrenner, D. P.; Elam, W. T.; Kintner, P. M. S.; Tyler, S.; Selker, J. S.
2016-12-01
At present, the logistical costs of ice drilling to depths of kilometers severely limit sampling and measurements beneath ice sheets. Thus only a tiny fraction of the 400 known subglacial lakes beneath the Antarctic Ice Sheet can ever be sampled by drilling, and study of large lakes may be limited to observations at one or, at best, a few sites. Antarctic lakes are likely highly diverse in their geochemical and geothermal fluxes, the timing and duration of their glaciations, and other characteristics. They constitute a remarkable collection of natural laboratories for learning biogeochemistries and adaptations of subglacial life on Earth. Moreover, they are arguably Earth-analogs to ice-covered seas on Europa and Enceladus, closer not only in relative terms than other analogs, but also usefully close in absolute terms for learning solar-system-wide features of ice-covered seas. It is therefore essential to sample Antarctic lakes with enough range and density, in space and time, to gain better understanding of their workings than drilling alone can provide. The logistics of thermal melt probes makes them attractive, provided that key limitations can be overcome. In particular, melt probes from the 1960s through the 1990s were unreliable, all halted in their descents by electrical failures at high voltages (which are necessary for efficient power use). Moreover, the hole above a classical melt probe refreezes, so neither samples nor the probe itself can be recovered. Here we report progress in overcoming both of these limitations with modern materials and components for reliable high-voltage operation. We have demonstrated in Greenland a 6.5 cm-diameter melt probe operating at 1050V/2.15 kW (electrical) that descended at 2.4 m/hr to 80 m depth in 2013, and after restarting in 2014, to 400 m depth, where we turned it off. We also operated a probe at 2000V/4.5 kW in 2014, which descended at 6.6 m/hr (according to a validated engineering model). These results are the second greatest depth and greatest speed attained by melt probes. We also report on testing a way to avoid complete refreezing of a melt hole, which enables cable deployment from the surface and thus small probes to reach and be recovered from great depth, as well as Raman Distributed Temperature Sensing of ice sheet temperatures, with several applications.
Pradeep, Avani R; Singh, Sonender P; Martande, Santosh S; Naik, Savitha B; N, Priyanka; Kalra, Nitish; Suke, Deepak K
2015-08-01
The aim of the present study was to evaluate the clinical and microbiological effect of systemic levofloxacin (LFX) as an adjunct to scaling and root planing (SRP) in patients with chronic periodontitis (CP). Sixty-five patients with CP were randomly divided into a test (n = 33, SRP and LFX 500 mg, once daily [o.d.]) and a control group (n = 32, SRP and placebo, o.d.). Plaque index (PI), gingival index (GI), percentage of sites with bleeding on probing (%BoP), probing depth (PD), and clinical attachment level (CAL) were recorded at baseline, 10 days, and 1-, 3-, and 6-month intervals. The percentage of sites positive for Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans), Porphyromonas gingivalis, and Tannerella forsythia were recorded at baseline and at 3 and 6 months. Patients receiving LFX showed statistically-significant improvements in mean PD and CAL. The intergroup difference in PI, GI, and%BoP was not significant at any interval. There was a reduction in the percentage of sites positive for periodontopathic bacteria over the duration of the study in both groups, and a statistically-significant reduction in the number of sites positive for A. actinomycetemcomitans in the LFX group (P < 0.001). Levofloxacin was found to significantly improve the clinical and microbiological parameters in CP individuals. © 2014 Wiley Publishing Asia Pty Ltd.
Cochrane, R Bruce; Sindelar, Betty
2015-01-01
To evaluate the clinical effects of a prescription tray application of hydrogen peroxide gel as an adjunct to frequent maintenance appointments for refractory periodontal patients. Case series data were analyzed from 66 failing periodontal maintenance patients who had exhausted treatment options before using prescription trays with a 1.7% hydrogen peroxide gel once or twice daily for two-and-a-half to five years. Data included pocket probing depths (PPD), bleeding on probing (BOP), smoking status, and compliance with tray usage. Data were collected prior to tray usage and after tray delivery at six months, one year, and annual intervals. A clinical and statistical reduction in BOP was maintained over the length of the study (p ≤ 0.01). No differences were seen in patients who used trays two times or one time a day or in patients who smoked or did not smoke. The 1.7% peroxide delivered via a prescription tray was most effective in shallow pockets. Aggregate PPD distribution did not change significantly. Of clinical relevance, only one tooth out of 1,745 teeth studied was lost due to periodontal disease during the study period. Prescription tray application of peroxide gel, as an adjunct to frequent periodontal maintenance appointments for refractory patients, demonstrated significant reductions in BOP'for smokers and non-smokers who used tray delivery once or twice a day.
Swierkot, Katrin; Brusius, Manuel; Leismann, Diana; Nonnenmacher, Claudia; Nüsing, Rolf; Lubbe, Dirk; Schade-Brittinger, Carmen; Mengel, Reiner
2013-01-01
The aim of the present study was to investigate plaque levels following sonic-powered and manual toothbrushing in subjects with dental implants. This study included 36 male and 47 female partially edentulous patients (age range 45-78 years, mean age 59.8 years) that were randomly assigned to one of two treatment groups: the sonic toothbrush group (n = 42; Philips Sonicare FlexCare® toothbrush) or the manual toothbrush group (n = 41; Oral-B P40®). Clinical, microbiological and immunological examinations were performed blinded at baseline and after 3, 6, 9 and 12 months. Microbiological analyses were performed by real-time polymerase chain reaction. Immunological analyses (prostaglandin E2) were performed by chromatography-electrospray spectrometry. The plaque index difference between baseline and 12 months at implants showed no significant difference between sonic or manual toothbrushing in a two-sided Mann-Whitney test (W = 773.5, P = 0.426, 95% CI -0.64 to 0.20). At the end of the study, there were no significant changes in plaque index, bleeding on probing, gingival index, pocket probing depth, gingival recession, clinical attachment level or the microbiological and immunological outcomes at implants or teeth in either group. This study uncovered no significant difference between sonic and manual toothbrushing for plaque reduction at implants and teeth. Both toothbrushes maintain healthy peri-implant soft tissue.
Morphological Computation of Haptic Perception of a Controllable Stiffness Probe
Sornkarn, Nantachai; Dasgupta, Prokar; Nanayakkara, Thrishantha
2016-01-01
When people are asked to palpate a novel soft object to discern its physical properties such as texture, elasticity, and even non-homogeneity, they not only regulate probing behaviors, but also the co-contraction level of antagonistic muscles to control the mechanical impedance of fingers. It is suspected that such behavior tries to enhance haptic perception by regulating the function of mechanoreceptors at different depths of the fingertips and proprioceptive sensors such as tendon and spindle sensors located in muscles. In this paper, we designed and fabricated a novel two-degree of freedom variable stiffness indentation probe to investigate whether the regulation of internal stiffness, indentation, and probe sweeping velocity (PSV) variables affect the accuracy of the depth estimation of stiff inclusions in an artificial silicon phantom using information gain metrics. Our experimental results provide new insights into not only the biological phenomena of haptic perception but also new opportunities to design and control soft robotic probes. PMID:27257814
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-24
... probes would be recorded by collaborating fishermen, along with information on location, depth fished... probes to gain information about fish distribution. Compensation fishing for this research would occur...
Noise filtering via electromagnetically induced transparency
NASA Astrophysics Data System (ADS)
Jeong, Taek; Bae, In-Ho; Moon, Han Seb
2017-01-01
We report on the intensity-noise reduction of pseudo-thermal light via electromagnetically induced transparency (EIT) in the Λ-type system of the 5S1/2-5P1/2 transition in 87Rb. Noise filtering of the pseudo-thermal probe light was achieved via an EIT filter and measured according to the degree of intensity noise of the pseudo-thermal probe light. Reductions in the intensity and spectral noise of the pseudo-thermal probe light with the EIT filter were observed using the direct intensity fluctuation and heterodyne detection technique, respectively. Comparison of the intensity noise of the pseudo-thermal probe light before and after passing through the EIT filter revealed a significant reduction in the intensity noise.
Alzarea, Bader K
2016-04-01
Peri-implant tissue health is a requisite for success of dental implant therapy. Plaque accumulation leads to initiation of gingivitis around natural teeth and peri-implantitis around dental implants. Peri-implantitis around dental implants may result in implant placement failure. For obtaining long-term success, timely assessment of dental implant site is mandatory. To assess and evaluate Quality of Life (OHRQoL) of individuals with dental implants using the Oral Health Impact Profile (OHIP-14). Total 92 patients were evaluated for assessment of the health of peri-implant tissues by recording, Plaque Index (PI), Probing Pocket Depth (PD), Bleeding On Probing (BOP) and Probing Attachment Level (PAL) as compared to contra-lateral natural teeth (control). In the same patients Quality of Life Assessment was done by utilizing Oral Health Impact Profile Index (OHIP-14). The mean plaque index around natural teeth was more compared to implants and it was statistically significant. Other three dimensions mean bleeding on probing; mean probing attachment level and mean pocket depth around both natural teeth and implant surfaces was found to be not statistically significant. OHIP-14 revealed that patients with dental implants were satisfied with their Oral Health-Related Quality of Life (OHRQoL). Similar inflammatory conditions are present around both natural teeth and implant prostheses as suggested by results of mean plaque index, mean bleeding on probing, mean pocket depth and mean probing attachment level, hence reinforcing the periodontal health maintenance both prior to and after incorporation of dental implants. Influence of implant prostheses on patient's oral health related quality of life (as depicted by OHIP-14) and patients' perceptions and expectations may guide the clinician in providing the best implant services.
Design and evaluation of a high sensitivity spiral TDR scour sensor
NASA Astrophysics Data System (ADS)
Gao, Quan; (Bill Yu, Xiong
2015-08-01
Bridge scour accounts for more than half of the reported bridge failures in the United States. Scour monitoring technology based on time domain reflectometry (TDR) features the advantages of being automatic and inexpensive. The senior author’s team has developed a few generations of a TDR bridge scour monitoring system, which have succeeded in both laboratory and field evaluations. In this study, an innovative spiral TDR sensor is proposed to further improve the sensitivity of the TDR sensor in scour detection. The spiral TDR sensor is made of a parallel copper wire waveguide wrapped around a mounting rod. By using a spiral path for the waveguide, the TDR sensor achieves higher sensitivity than the traditional straight TDR probes due to longer travel distance of the electromagnetic (EM) wave per unit length in the spiral probe versus traditional probe. The performance of the new TDR spiral scour sensor is validated by calibration with liquids with known dielectric constant and wet soils. Laboratory simulated scour-refilling experiments are performed to evaluate the performance of the new spiral probe in detecting the sediment-water interface and therefore the scour-refill process. The tests results indicate that scour depth variation of less than 2 cm can be easily detected by this new spiral sensor. A theory is developed based on the dielectric mixing model to simplify the TDR signal analyses for scour depth detection. The sediment layer thickness (directly related to scour depth) varies linearly with the square root of the bulk dielectric constant of the water-sediment mixture measured by the spiral TDR probe, which matches the results of theoretical prediction. The estimated sediment layer thickness and therefore scour depth from the spiral TDR sensor agrees very well with that by direct physical measurement. The spiral TDR sensor is four times more sensitive than a traditional straight TDR probe.
Quantitative operando visualization of the energy band depth profile in solar cells.
Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei
2015-07-13
The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference.
Quantitative operando visualization of the energy band depth profile in solar cells
Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei
2015-01-01
The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference. PMID:26166580
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hristov, D; Schlosser, J; Bazalova, M
2014-06-01
Purpose: To quantify the effect of ultrasound (US) probe beam attenuation for radiation therapy delivered under real-time US image guidance by means of Monte Carlo (MC) simulations. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their CT images in the EGSnrc BEAMnrc and DOSXYZnrc codes. Due to the metal parts, the probes were scanned in a Tomotherapy machine with a 3.5 MV beam. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2–8.0 g/cm{sup 3}.more » Beam attenuation due to the probes was measured in a solid water phantom for a 6 MV and 15 MV 15x15 cm{sup 2} beam delivered on a Varian Trilogy linear accelerator. The dose was measured with the PTW-729 ionization chamber array at two depths and compared to MC simulations. The extreme case beam attenuation expected in robotic US image guided radiotherapy for probes in upright position was quantified by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities were 4.6 and 4.2 g/cm{sup 3} in the C5-2 and X6-1 probe, respectively. Gamma analysis of the simulated and measured doses revealed that over 98% of measurement points passed the 3%/3mm criteria for both probes and measurement depths. The extreme attenuation for probes in upright position was found to be 25% and 31% for the C5-2 and X6-1 probe, respectively, for both 6 and 15 MV beams at 10 cm depth. Conclusion: MC models of two US probes used for real-time image guidance during radiotherapy have been built. As a Result, radiotherapy treatment planning with the imaging probes in place can now be performed. J Schlosser is an employee of SoniTrack Systems, Inc. D Hristov has financial interest in SoniTrack Systems, Inc.« less
Singh, Sangeeta
2009-01-01
To evaluate the efficacy of platelet-rich plasma concentrate in the management of a cirumferential, infrabony defect associated with an endoperio lesion in a maxillary canine. A 45 year-old male patient with an endoperio lesion in the left maxillary canine was initially treated with endodontic therapy. Following the endodontic treatment, the circumferential, infrabony defect was treated using platelet-rich plasma and an alloplastic bone substitute. At the end of three months, there was a gain in the clinical attachment level and reduction in probing depth. Radiographic evidence showed that there was significant bony fill. The results were maintained at the time of recall nine months later. PMID:20407658
Berkowitz, Bruce A.; Gorgis, Jawan; Patel, Ankit; Baameur, Faiza; Gurevich, Vsevolod V.; Craft, Cheryl M.; Kefalov, Vladimir J.; Roberts, Robin
2015-01-01
Rod tetrameric arrestin 1 (tet-ARR1), stored in the outer nuclear layer/inner segments in the dark, modulates photoreceptor synaptic activity; light exposure stimulates a reduction via translocation to the outer segments for terminating G-protein coupled phototransduction signaling. Here, we test the hypothesis that intraretinal spin-lattice relaxation rate in the rotating frame (1/T1ρ), an endogenous MRI contrast mechanism, has high potential for evaluating rod tet-ARR1 and its reduction via translocation. Dark- and light-exposed mice (null for the ARR1 gene, overexpressing ARR1, diabetic, or wild type with or without treatment with Mn2+, a calcium channel probe) were studied using 1/T1ρ MRI. Immunohistochemistry and single-cell recordings of the retinas were also performed. In wild-type mice with or without treatment with Mn2+, 1/T1ρ of avascular outer retina (64% to 72% depth) was significantly (P < 0.05) greater in the dark than in the light; a significant (P < 0.05) but opposite pattern was noted in the inner retina (<50% depth). Light-evoked outer retina Δ1/T1ρ was absent in ARR1-null mice and supernormal in overexpressing mice. In diabetic mice, the outer retinal Δ1/T1ρ pattern suggested normal dark-to-light tet-ARR1 translocation and chromophore content, conclusions confirmed ex vivo. Light-stimulated Δ1/T1ρ in inner retina was linked to changes in blood volume. Our data support 1/T1ρ MRI for noninvasively assessing rod tet-ARR1 and its reduction via protein translocation, which can be combined with other metrics of retinal function in vivo.—Berkowitz, B. A., Gorgis, J., Patel, A., Baameur, F., Gurevich, V. V., Craft, C. M., Kefalov, V. J., Roberts, R. Development of an MRI biomarker sensitive to tetrameric visual arrestin 1 and its reduction via light-evoked translocation in vivo. PMID:25351983
Costa, Luciana; do Nascimento, Cássio; de Souza, Valéria Oliveira Pagnano; Pedrazzi, Vinícius
2017-03-01
The aim of this study was assessing the changes in both clinical and microbiological parameters of healthy individuals after rehabilitation with removable partial denture (RPD). 11 women received unilateral or bilateral free-end saddle RPD in the mandibular arch. Clinical and microbiological parameters of abutment, non-abutment, and antagonist teeth were assessed at baseline (RPD installation) and after 7, 30, 90, and 180days of function. The Checkerboard DNA-DNA hybridization technique was used to identify and quantify up to 43 different microbial species from subgingival biofilm samples. Probing depth, gingival recession, and bleeding on probing were also investigated over time. The total and individual microbial genome counts were shown significantly increased after 180days with no significant differences between abutment, non-abutment, or antagonist teeth. Streptococcus spp., Aggregatibacter actinomycetemcomitans, and other species associated to periodontitis (Peptostreptococcus anaerobius, Prevotella nigrescens, and Tannerella forsythia), as well as opportunistic Candida spp., were recovered in moderate counts. Abutment teeth presented higher values of gingival recession when compared with non-abutment or antagonist teeth, irrespectively time of sampling (p<0.05). No significant differences were found between groups regarding bleeding on probing or probing depth over time. Overall, the microbial counts significantly increased after 6 months of denture loading for both abutment and non-abutment teeth with no significant differences regarding the microbial profile over time. Bleeding on probing and probing depth showed no significant difference between groups over time whereas gingival recession increased in the abutment teeth. Copyright © 2016 Elsevier Ltd. All rights reserved.
Montero, Javier; Mazzaglia, Giuseppe
2011-11-01
The aim of this study was to evaluate the change in the periodontal status of mandibular second molars after surgical extraction of adjacent impacted lower third molars. The study was based on a 1-year follow-up of 48 patients (20 men and 28 women) recruited consecutively after the extraction of an impacted lower third molar. Panoramic radiographs were obtained and clinical examinations were carried out at baseline to determine the periodontal status (probing depth and dental plaque and gingival indices) both for the second molar and for the 4 posterior sextants. After surgical removal of the impacted mandibular third molars, all patients were assessed at 3, 6, 9, and 12 months for changes in periodontal status. The periodontal health of the second molar was found to improve gradually after third molar surgery in all clinical parameters. Probing depth was gradually reduced by about 0.6 mm quarterly, until a final depth of 2.6 ± 0.8 mm was attained. The relative risk of having a plaque index and gingival index coded as 0 (healthy) or 1 (minor problems) was about 10 times higher at the end of the follow-up than at baseline for both indices. The periodontal status of the 4 posterior sextants also improved gradually. Molar depth, according to the Pell and Gregory classes and types, seemed to be the main factor modulating both the baseline probing depth and the change in probing depth during follow-up. Our results suggest that the initial periodontal breakdown established on the distal surfaces of the second molars and in the periodontal health of the 4 posterior sextants can be significantly improved 1 year after surgical removal of the ipsilateral lower third molar. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Long-wavelength analyte-sensitive luminescent probes and optical (bio)sensors
Staudinger, Christoph; Borisov, Sergey M
2016-01-01
Long-wavelength luminescent probes and sensors become increasingly popular. They offer the advantage of lower levels of autofluorescence in most biological probes. Due to high penetration depth and low scattering of red and NIR light such probes potentially enable in vivo measurements in tissues and some of them have already reached a high level of reliability required for such applications. This review focuses on the recent progress in development and application of long-wavelength analyte-sensitive probes which can operate both reversibly and irreversibly. Photophysical properties, sensing mechanisms, advantages and limitations of individual probes are discussed. PMID:27134748
Investigation of eddy current examination on OD fatigue crack for steam generator tubes
NASA Astrophysics Data System (ADS)
Kong, Yuying; Ding, Boyuan; Li, Ming; Liu, Jinhong; Chen, Huaidong; Meyendorf, Norbert G.
2015-03-01
The opening width of fatigue crack was very small, and conventional Bobbin probe was very difficult to detect it in steam generator tubes. Different sizes of 8 fatigue cracks were inspected using bobbin probe rotating probe. The analysis results showed that, bobbin probe was not sensitive for fatigue crack even for small through wall crack mixed with denting signal. On the other hand, the rotating probe was easily to detect all cracks. Finally, the OD phase to depth curve for fatigue crack using rotating probe was established and the results agreed very well with the true crack size.
Brajkovic, Dragan; Ducharme, Michel B
2005-07-01
This study evaluated a zero-heat-flow (ZHF), non-invasive temperature probe for in- vivo measurement of resting muscle temperature for up to 2 cm below the skin surface. The ZHF probe works by preventing heat loss from the tissue below the probe by actively heating the tissue until no temperature gradient exists across the probe. The skin temperature under the probe is then used as an indicator of the muscle temperature below. Eight subjects sat for 130 min during exposure to 28 degrees C air. Vastus lateralis (lateral thigh) muscle temperature was measured non-invasively using a ZHF probe which covered an invasive multicouple probe (which measured tissue temperature 0.5 cm, 1 cm, 1.5 cm, and 2 cm below the skin) located 15 cm superior to the patella (T (covered)). T (covered) was evaluated against an uncovered control multicouple probe located 20 cm superior to the patella (T (uncovered)). Rectal temperature and lateral thigh skin temperature were also measured. Mean T (uncovered) (based on average temperatures at the 0.5 cm, 1 cm, 1.5 cm, and 2 cm depths) and Mean T (covered) were similar from time 0 min to 60 min. However, when the ZHF was turned on at 70 min, Mean T (covered) increased by 2.11 +/- 0.20 degrees C by 130 min, while T (uncovered) remained stable. The ZHF probe temperature was similar to T (covered) at 1 cm and after time 85 min, significantly higher than T (covered) at the 0.5 cm, 1.5 cm, and 2 cm depths; however from a physiological standpoint, the temperatures between the different depths and the ZHF probe could be considered uniform (< or =0.2 degrees C separation). Rectal and thigh skin temperatures were stable at 36.99 +/- 0.08 degrees C and 32.82 +/- 0.23 degrees C, respectively. In conclusion, the non-invasive ZHF probe temperature was similar to the T (covered) temperatures directly measured up to 2 cm beneath the surface of the thigh, but all T (covered) temperatures were not representative of the true muscle temperature up to 2 cm below the skin because the ZHF probe heated the muscle by 2.11 +/- 0.20 degrees C during its operation.
Constraining the CMB optical depth through the dispersion measure of cosmological radio transients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fialkov, A.; Loeb, A., E-mail: anastasia.fialkov@cfa.harvard.edu, E-mail: aloeb@cfa.harvard.edu
2016-05-01
The dispersion measure of extragalactic radio transients can be used to measure the column density of free electrons in the intergalactic medium. The same electrons also scatter the Cosmic Microwave Background (CMB) photons, affecting precision measurements of cosmological parameters. We explore the connection between the dispersion measure of radio transients existing during the Epoch of Reionization (EoR) and the total optical depth for the CMB showing that the existence of such transients would provide a new sensitive probe of the CMB optical depth. As an example, we consider the population of FRBs. Assuming they exist during the EoR, we showmore » that: (i) such sources can probe the reionization history by measuring the optical depth to sub-percent accuracy, and (ii) they can be detected with high significance by an instrument such as the Square Kilometer Array.« less
Smart textile plasmonic fiber dew sensors.
Esmaeilzadeh, Hamid; Rivard, Maxime; Arzi, Ezatollah; Légaré, François; Hassani, Alireza
2015-06-01
We propose a novel Surface Plasmon Resonance (SPR)-based sensor that detects dew formation in optical fiber-based smart textiles. The proposed SPR sensor facilitates the observation of two phenomena: condensation of moisture and evaporation of water molecules in air. This sensor detects dew formation in less than 0.25 s, and determines dew point temperature with an accuracy of 4%. It can be used to monitor water layer depth changes during dew formation and evaporation in the range of a plasmon depth probe, i.e., 250 nm, with a resolution of 7 nm. Further, it facilitates estimation of the relative humidity of a medium over a dynamic range of 30% to 70% by measuring the evaporation time via the plasmon depth probe.
Park, Kyoung-Duck; Park, Doo Jae; Lee, Seung Gol; Choi, Geunchang; Kim, Dai-Sik; Byeon, Clare Chisu; Choi, Soo Bong; Jeong, Mun Seok
2014-02-21
A resonant shift and a decrease of resonance quality of a tuning fork attached to a conventional fiber optic probe in the vicinity of liquid is monitored systematically while varying the protrusion length and immersion depth of the probe. Stable zones where the resonance modification as a function of immersion depth is minimized are observed. A wet near-field scanning optical microscope (wet-NSOM) is operated for a sample within water by using such a stable zone.
Stein, Jamal M; Hammächer, Christian; Said-Yekta Michael, Sareh
2017-09-15
The aim of this study was to evaluate the clinical outcomes of a concept for non-surgical peri-implantitis combining stepwise mechanical debridement measures with adjuvant Povidone-iodine application with and without systemic antibiotics. 45 patients with chronic periodontitis comprising 164 screw-typed implants with peri-implantitis were included. Peri-implantitis was defined as radiographic bone loss of >2 mm, probing pocket depth (PD) ≥5 mm with bleeding on probing (BOP). Stepwise treatment of implants was performed with ultrasonic debridement, soft tissue curettage (STC), glycine powder air polishing (GPAP) and a repeated submucosal application of Povidone-iodine. Teeth with PD >4mm were treated simultaneously according to the same concept except STC. In cases with severe periodontitis (N = 24), amoxicillin and metronidazole (AM) were prescribed for 7 days. After 12 months, implants treated without AM showed significant reductions (p<0.05) of mean PD (1.4 ± 0.7 mm), CAL (1.3 ± 0.8 mm) and BOP (33.4 ± 17.2%). In deep pockets (PD >6mm) changes of mean PD (2.3 ± 1.3 mm), CAL (2.0 ± 1.6 mm) and BOP (44.0 ± 41.7%) were more pronounced. Intake of AM did not significantly influence the changes of these parameters. However, the reduction of implant sites with PD >4 mm and BOP was significantly higher in patients with AM than in those without AM (31.8 ± 12.6% vs. 20.8 ± 14.7%; p<0.05). The combination of ultrasonic debridement, STC and GPAP with adjuvant Povidone-iodine led to significant clinical improvements at implants. Systemic antibiotics had limited effects on the reduction of persisting implant sites with treatment need.
Assem, Naida Zanini; Alves, Márcio Luiz Ferro; Lopes, Alessandra Barreto; Gualberto, Erivan Clementino; Garcia, Valdir Gouveia; Theodoro, Letícia Helena
2017-07-03
The aim of this study was to perform a systematic review and meta-analysis to examine the effect of systemic antibiotics in the periodontal treatment of smokers. The selection criteria were as follows: controlled randomized clinical trials; studies published in English; studies with smoker patients diagnosed with chronic periodontitis; patients without systemic diseases; studies that used systemic antibiotic therapy associated with periodontal treatment; studies that presented results for the test and control groups and assessments of clinical periodontal parameters, such as probing depth (PD), bleeding on probing (BOP), and clinical attachment level (CAL). The differences in average weights were calculated with a confidence interval (CI) of 95% for PD reduction, CAL gain and BOP. The means of the periodontal clinical parameters were compared between the baseline and post-treatment periods between the test groups and the control groups. The heterogeneity was assessed using the Cochran Q test (Q (df = 3), α = 5%). A total of 67 articles were found, and after the selection process, three randomized controlled trials were included in the meta-analysis. The results indicate that SRP associated with systemic antibiotics promoted additional benefits when compared to SRP alone, with a greater reduction of PD (p = 0.0359, CI = -0.42, -0.01) and a gain of CAL (p = 0.0161, CI = -0.39, -0.04). There was a modest PD reduction (PD, DM -0.21) and a modest CAL gain (CAL, DM -0.22). The results of our meta-analysis reveal the clinical benefits of systemic antibiotics as an adjunct to the non-surgical periodontal treatment of smokers. These clinical improvements, although statistically significant, appeared to be of little clinical relevance.
Grzech-Leśniak, K; Sculean, A; Gašpirc, Boris
2018-05-15
The objective of this study was to evaluate the microbiological and clinical outcomes following nonsurgical treatment by either scaling and root planing, combination of Nd:YAG and Er:YAG lasers, or by Er:YAG laser treatment alone. The study involved 60 patients with generalized chronic periodontitis, randomly assigned into one of three treatment groups of 20 patients. The first group received scaling and root planing by hand instruments (SRP group), the second group received Er:YAG laser treatment alone (Er group), and the third group received combined treatment with Nd:YAG and Er:YAG lasers (NdErNd group). Microbiological samples, taken from the periodontal pockets at baseline and 6 months after treatments, were assessed with PET Plus tests. The combined NdErNd laser (93.0%), followed closely by Er:YAG laser (84.9%), treatment resulted in the highest reduction of all bacteria count after 6 months, whereas SRP (46.2%) failed to reduce Treponema denticola, Peptostreptococcus micros, and Capnocytophaga gingivalis. Full-mouth plaque and bleeding on probing scores dropped after 6 months and were the lowest in both laser groups. The combination of NdErNd resulted in higher probing pocket depth reduction and gain of clinical attachment level (1.99 ± 0.23 mm) compared to SRP (0.86 ± 0.13 mm) or Er:YAG laser alone (0.93 ± 0.20 mm) in 4-6 mm-deep pockets. Within their limits, the present results provide support for the combination of Nd:YAG and Er:YAG lasers to additionally improve the microbiological and clinical outcomes of nonsurgical periodontal therapy in patients with moderate to severe chronic periodontitis.
Offenbacher, Steven; Beck, James D; Moss, Kevin; Mendoza, Luisito; Paquette, David W; Barrow, David A; Couper, David J; Stewart, Dawn D; Falkner, Karen L; Graham, Susan P; Grossi, Sara; Gunsolley, John C; Madden, Theresa; Maupome, Gerardo; Trevisan, Maurizio; Van Dyke, Thomas E; Genco, Robert J
2009-02-01
In the Periodontitis and Vascular Events (PAVE) pilot study, periodontal therapy was provided as an intervention in a secondary cardiac event prevention model through five coordinated cardiac-dental centers. Subjects were randomized to either community care or protocol provided scaling and root planing to evaluate effects on periodontal status and systemic levels of high-sensitivity C-reactive protein (hs-CRP). After 6 months, there was a significant reduction in mean probing depth and extent of 4- or 5-mm pockets. However, there were no significant differences in attachment levels, bleeding upon probing, or extent of subgingival calculus comparing subjects assigned to protocol therapy (n = 151) to those assigned to community care (n = 152). Using intent-to-treat analyses, there was no significant effect on serum hs-CRP levels at 6 months. However, 48% of the subjects randomized to community care received preventive or periodontal treatments. Secondary analyses demonstrated that consideration of any preventive or periodontal care (i.e., any treatment) compared to no treatment showed a significant reduction in the percentage of people with elevated hs-CRP (values >3 mg/l) at 6 months. However, obesity nullified the periodontal treatment effects on hs-CRP reduction. The adjusted odds ratio for hs-CRP levels >3 mg/l at 6 months for any treatment versus no treatment among non-obese individuals was 0.26 (95% confidence interval: 0.09 to 0.72), adjusting for smoking, marital status, and gender. This pilot study demonstrated the critical role of considering obesity as well as rigorous preventive and periodontal care in trials designed to reduce cardiovascular risk.
Offenbacher, Steven; Beck, James D.; Moss, Kevin; Mendoza, Luisito; Paquette, David W.; Barrow, David A.; Couper, David J.; Stewart, Dawn D.; Falkner, Karen L.; Graham, Susan P.; Grossi, Sara; Gunsolley, John C.; Madden, Theresa; Maupome, Gerardo; Trevisan, Maurizio; Van Dyke, Thomas E.; Genco, Robert J.
2009-01-01
Background In the Periodontitis and Vascular Events (PAVE) pilot study, periodontal therapy was provided as an intervention in a secondary cardiac event prevention model through five coordinated cardiac– dental centers. Methods Subjects were randomized to either community care or protocol provided scaling and root planing to evaluate effects on periodontal status and systemic levels of high-sensitivity C-reactive protein (hs-CRP). Results After 6 months, there was a significant reduction in mean probing depth and extent of 4- or 5-mm pockets. However, there were no significant differences in attachment levels, bleeding upon probing, or extent of subgingival calculus comparing subjects assigned to protocol therapy (n = 151) to those assigned to community care (n = 152). Using intent-to-treat analyses, there was no significant effect on serum hs-CRP levels at 6 months. However, 48% of the subjects randomized to community care received preventive or periodontal treatments. Secondary analyses demonstrated that consideration of any preventive or periodontal care (i.e., any treatment) compared to no treatment showed a significant reduction in the percentage of people with elevated hs-CRP (values >3 mg/l) at 6 months. However, obesity nullified the periodontal treatment effects on hs-CRP reduction. The adjusted odds ratio for hs-CRP levels >3 mg/l at 6 months for any treatment versus no treatment among non-obese individuals was 0.26 (95%confidence interval: 0.09 to 0.72), adjusting for smoking, marital status, and gender. Conclusion This pilot study demonstrated the critical role of considering obesity as well as rigorous preventive and periodontal care in trials designed to reduce cardiovascular risk. PMID:19186958
Autologous Platelet-rich Plasma after Third Molar Surgery
Gandevivala, Adil; Sangle, Amit; Shah, Dinesh; Tejnani, Avneesh; Sayyed, Aatif; Khutwad, Gaurav; Patel, Arpit Arunbhai
2017-01-01
Aim and Objective: The aim of this study is to compare the efficacy of autologous platelet-rich plasma (PRP) in the third molar impactions, with respect to: pain, swelling, healing, and periodontal status distal to the second molar in patients who need surgical removal of bilateral impacted mandibular third molars. Materials and Methods: Twenty-five patients of both sexes aged between 16 and 60 years who required bilateral surgical removal of their impacted third molars and met the inclusion criteria were included in the study. After surgical extraction of the third molar, primary closure was performed in the control group, whereas PRP was placed in the socket followed by primary closure in the case group. The outcome variables were pain, swelling, wound healing, and periodontal probe depth that were follow-up period of 2 months. Quantitative data are presented as mean. Statistical significance was checked by t-test. Results: There was a difference in the pain (0.071) and facial swelling (0.184), reduction between test and control on day 3, but it was not found to be significant. Periodontal pocket depth (0.001) and wound healing (0.001) less in case group compared with the control group was found to be significant. Conclusion: The use of PRP lessens the severity of immediate postoperative sequelae and decreases preoperative pocket depth. PMID:29264293
Trombelli, L; Scabbia, A; Tatakis, D N; Calura, G
1998-11-01
The purpose of the present clinical study was to evaluate the effect of guided tissue regeneration (GTR) in comparison to subpedicle connective tissue graft (SCTG) in the treatment of gingival recession defects. A total of 12 patients, each contributing a pair of Miller's Class I or II buccal gingival recessions, was treated. According to a randomization list, one defect in each patient received a polyglycolide/lactide bioabsorbable membrane, while the paired defect received a SCTG. Treatment effect was evaluated 6 months postsurgery. Clinical recordings included full-mouth and defect-specific oral hygiene standards and gingival health, recession depth (RD), recession width (RW), probing depth (PD), clinical attachment level (CAL), and keratinized tissue width (KT). Mean RD significantly decreased from 3.1 mm presurgery to 1.5 mm at 6 months postsurgery for the GTR group (48% root coverage), and from 3.0 mm to 0.5 mm for the SCTG group (81% root coverage). RD reduction and root coverage were significantly greater in SCTG group compared to GTR group. Mean CAL gain amounted to 1.7 mm for the GTR group, and 2.3 mm in the SCTG group. No significant differences in PD changes were observed within and between groups. KT increased significantly from presurgery for both treatment groups, however gingival augmentation was significantly greater in the SCTG group compared to GTR group. Results indicate that: 1) treatment of human gingival recession defects by means of both GTR and SCTG procedures results in clinically and statistically significant improvement of the soft tissue conditions of the defect; and 2) treatment outcome was significantly better following SCTG compared to GTR in terms of recession depth reduction, root coverage, and keratinized tissue increase.
Hamed, Saja H; Altrabsheh, Bilal; Assa'd, Tareq; Jaradat, Said; Alshra'ah, Mohammad; Aljamal, Abdulfattah; Alkhatib, Hatim S; Almalty, Abdul-Majeed
2012-12-01
Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. The purpose of this work was to develop a simple inexpensive conductance meter for the objective in vivo evaluation of skin hydration. The conductance meter probe was designed using the basic equation governing wave propagation along Transverse Electromagnetic transmission lines. It consisted of two concentric copper circular electrodes printed on FR4 dielectric material. The performance of the probe was validated by evaluating its measurement depth, its ability to monitor in vitro water sorption-desorption and in vivo skin hydration effect in comparison to that of the Corneometer CM 825. The measurement depth of the probe, 15 μm, was comparable to that of CM 825. The in vitro readings of the probe correlated strongly with the amount of water adsorbed on filter paper. Skin hydration after application of a moisturizer was monitored effectively by the new probe with good correlation to the results of CM 825. In conclusion, a simple probe for evaluating skin hydration was made from off-the-shelf materials and its performance was validated in comparison to a commercially available probe. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
The effect of periodontal treatment on C-reactive protein: A clinical study.
Kumar, Santosh; Shah, Samir; Budhiraja, Shilpa; Desai, Khushboo; Shah, Chirag; Mehta, Dhaval
2013-07-01
Chronic periodontitis in amultifactorial inflammatory disease which is caused by various microorganisms. Many studies have found close association between chronic periodontitis and C-reactive protein (CRP). CRPis an inflammatory marker which increases in all inflammatory condition. The present clinical study was designed to show the effect of periodontal treatment on the CRP levels of gingival crevicular fluid and to determine the effect of nonsurgical therapy in minimizing the CRP levels in chronic generalized periodontitis. Gingival crevicular fluid was collected using a micro capillary pipette that was hand calibrated at every 1 mm till 10 mm, from selected sites in the subjects on the 1st, 14th and 45th days. Decreased CRP levels of gingival crevicular fluid were observed at the end of the study. There was a 37% reduction in probing pocket depth and 45% gain in clinical attachment level and a reduction of about 57% after 14 days and 90% reduction of CRP levels in gingival crevicular fluid after 45 days. Thus, the results show that the presence of CRP level is more significant in gingival crevicular fluid and confirms the underlying inflammatory component of the disease activity in chronic periodontitis.
A new algorithm for five-hole probe calibration, data reduction, and uncertainty analysis
NASA Technical Reports Server (NTRS)
Reichert, Bruce A.; Wendt, Bruce J.
1994-01-01
A new algorithm for five-hole probe calibration and data reduction using a non-nulling method is developed. The significant features of the algorithm are: (1) two components of the unit vector in the flow direction replace pitch and yaw angles as flow direction variables; and (2) symmetry rules are developed that greatly simplify Taylor's series representations of the calibration data. In data reduction, four pressure coefficients allow total pressure, static pressure, and flow direction to be calculated directly. The new algorithm's simplicity permits an analytical treatment of the propagation of uncertainty in five-hole probe measurement. The objectives of the uncertainty analysis are to quantify uncertainty of five-hole results (e.g., total pressure, static pressure, and flow direction) and determine the dependence of the result uncertainty on the uncertainty of all underlying experimental and calibration measurands. This study outlines a general procedure that other researchers may use to determine five-hole probe result uncertainty and provides guidance to improve measurement technique. The new algorithm is applied to calibrate and reduce data from a rake of five-hole probes. Here, ten individual probes are mounted on a single probe shaft and used simultaneously. Use of this probe is made practical by the simplicity afforded by this algorithm.
Webster, Gordon; Rinna, Joachim; Roussel, Erwan G; Fry, John C; Weightman, Andrew J; Parkes, R John
2010-05-01
Stable isotope probing of prokaryotic DNA was used to determine active prokaryotes using (13)C-labelled substrates (glucose, acetate, CO(2)) in sediment slurries from different biogeochemical zones of the Severn Estuary, UK. Multiple, low concentrations (5 x 100 microM) of (13)C-substrate additions and short-term incubations (7 days) were used to minimize changes in the prokaryotic community, while achieving significant (13)C-incorporation. Analysis demonstrated clear metabolic activity within all slurries, although neither the net sulphate removal nor CH(4) production occurred in the anaerobic sulphate reduction and methanogenesis zone slurries. Some similarities occurred in the prokaryotic populations that developed in different sediment slurries, particularly in the aerobic and dysaerobic zone slurries with (13)C-glucose, which were dominated by Gammaproteobacteria and Marine Group 1 Archaea, whereas both anaerobic sediment slurries incubated with (13)C-acetate showed incorporation into Epsilonproteobacteria and other bacteria, with the sulphate reduction zone slurry also showing (13)C-acetate utilization by Miscellaneous Crenarchaeotic Group Archaea. The lower potential energy methanogenesis zone slurries were the only conditions where no (13)C-incorporation into Archaea occurred, despite Bacteria being labelled; this was surprising because Archaea have been suggested to be adapted to low-energy conditions. Overall, our results highlight that uncultured prokaryotes play important ecological roles in tidal sediments of the Severn Estuary, providing new metabolic information for novel groups of Archaea and suggesting broader metabolisms for largely uncultivated Bacteria.
Pulsed-induced electromagnetically induced transparency in the acetylene-filled hollow-core fibers
NASA Astrophysics Data System (ADS)
Rodríguez, Nayeli Casillas; Stepanov, Serguei; Miramontes, Manuel Ocegueda; Hernández, Eliseo Hernández
2017-06-01
Experimental results on pulsed excitation of electromagnetically induced transparency (EIT) in the acetylene-filled hollow-core photonic crystal fiber (HC-PCF) at pressures 0.1-0.4 Torr are reported. The EIT was observed both in Λ and V interaction configurations with the continuous probe wave tuned to R9 (1520.08 nm) acetylene absorption line and with the control pulses tuned to P11 (1531.58 nm) and P9 (1530.37 nm) lines, respectively. The utilized control pulses were of up to 40 ns duration with <2.5 ns fronts and with maximum input power 1 W. The maximum modulation depth of the initial probe wave absorption via EIT was up to 40 and 15% for the co- and counter-propagation of the probe and control waves, respectively, and importance of the waves polarization matching was demonstrated. For a qualitative explanation of reduction in the counter-propagation EIT efficiency a simple model of the accelerated mismatch of the two-frequency EIT resonance with deviation of the molecule thermal velocity from the resonance value was utilized. It was shown experimentally that the EIT efficiencies in both configurations do not depend on the longitudinal velocity of the molecules. The characteristic relaxation time of the of the EIT response was found to be about 9 ns, i.e., is close to the relaxation times T 1,2 of the acetylene molecules under the utilized experimental conditions.
Whitehead, S P; Watts, T L
1987-11-01
Keyes' method of non-surgical therapy was compared with modified Widman flap surgery in 9 patients with symmetrical periodontal disease. Following an initial oral hygiene programme, baseline measurements were recorded and paired contralateral areas were subjected randomly to the 2 techniques. 42 teeth receiving surgery were compared with 40 treated by Keyes' method. 6 sites per tooth were scored immediately prior to therapy and 3 months later, using a constant force probe with onlays. Consistent data were recorded for the 6 separate sites, which showed no baseline difference between treatments, slightly greater recession with surgery at 3 months, but no difference between treatments in probing depth and attachment levels. Mean data for individual patients showed similar consistency. Probing depth in deep sites was reduced slightly more with surgery, and there were no differences in bleeding on probing at 3 months. Both techniques gave marked improvements in health. Surprisingly, only 2 subjects preferred Keyes' technique of mechanical therapy, 6 preferred surgery, and 1 had no preference.
Sutej, Ivana; Peros, Kristina; Benutic, Anica; Capak, Krunoslav; Basic, Kresimir; Rosin-Grget, Kata
2012-01-01
To evaluate the effect of tobacco smoking and salivary calcium on the periodontal status of young adults. Plaque index, gingival bleeding on probing, supragingival calculus, DMFT index, salivary flow, pH and salivary calcium in unstimulated salivary samples were recorded in smokers and nonsmokers. There were no significant differences between smokers and nonsmokers with respect to salivary flow (P = 0.08) and calcium level (P = 0.09). Significant correlations (P < 0.05) were found between a higher calcium level and higher probing depth (r = 0.60), higher number of teeth with probing depth of more than 4 mm (r = 0.70), greater clinical attachment level (r = 0.49) and lower number of teeth bleeding on probing (r = -0.50). Moderate smoking of tobacco cigarettes in young healthy subjects may not have a significant impact on salivary flow or calcium concentrations in unstimulated saliva, but an association exists between an increased level of salivary calcium and development of periodontal disease.
Optical probe for porosity defect detection on inner diameter surfaces of machined bores
NASA Astrophysics Data System (ADS)
Kulkarni, Ojas P.; Islam, Mohammed N.; Terry, Fred L.
2010-12-01
We demonstrate an optical probe for detection of porosity inside spool bores of a transmission valve body with diameters down to 5 mm. The probe consists of a graded-index relay rod that focuses a laser beam spot onto the inner surface of the bore. Detectors, placed in the specular and grazing directions with respect to the incident beam, measure the change in scattered intensity when a surface defect is encountered. Based on the scattering signatures in the two directions, the system can also validate the depth of the defect and distinguish porosity from bump-type defects coming out of the metal surface. The system can detect porosity down to a 50-μm lateral dimension and ~40 μm in depth with >3-dB contrast over the background intensity fluctuations. Porosity detection systems currently use manual inspection techniques on the plant floor, and the demonstrated probe provides a noncontact technique that can help automotive manufacturers meet high-quality standards during production.
Dose verification of eye plaque brachytherapy using spectroscopic dosimetry.
Jarema, T; Cutajar, D; Weaver, M; Petasecca, M; Lerch, M; Kejda, A; Rosenfeld, A
2016-09-01
Eye plaque brachytherapy has been developed and refined for the last 80 years, demonstrating effective results in the treatment of ocular malignancies. Current dosimetry techniques for eye plaque brachytherapy (such as TLD- and film-based techniques) are time consuming and cannot be used prior to treatment in a sterile environment. The measurement of the expected dose distribution within the eye, prior to insertion within the clinical setting, would be advantageous, as any errors in source loading will lead to an erroneous dose distribution and inferior treatment outcomes. This study investigated the use of spectroscopic dosimetry techniques for real-time quality assurance of I-125 based eye plaques, immediately prior to insertion. A silicon detector based probe, operating in spectroscopy mode was constructed, containing a small (1 mm(3)) silicon detector, mounted within a ceramic holder, all encapsulated within a rubber sheath to prevent water infiltration of the electronics. Preliminary tests of the prototype demonstrated that the depth dose distribution through the central axis of an I-125 based eye plaque may be determined from AAPM Task Group 43 recommendations to a deviation of 6 % at 3 mm depth, 7 % at 5 mm depth, 1 % at 10 mm depth and 13 % at 20 mm depth, with the deviations attributed to the construction of the probe. A new probe design aims to reduce these discrepancies, however the concept of spectroscopic dosimetry shows great promise for use in eye plaque quality assurance in the clinical setting.
de Souza, Sérgio Luís Scombatti; Novaes, Arthur Belém; Grisi, Daniela Corrêa; Taba, Mário; Grisi, Márcio Fernando de Moraes; de Andrade, Patrícia Freitas
2008-07-01
Different techniques have been proposed for the treatment of gingival recession. This study compared the clinical results of gingival recession treatment using a subepithelial connective tissue graft and an acellular dermal matrix allograft. Seven patients with bilateral Miller class I or II gingival recession were selected. Twenty-six recessions were treated and randomly assigned to the test group. In each case the contralateral recession was assigned to the control group. In the control group, a connective tissue graft in combination with a coronally positioned flap was used; in the test group, an acellular dermal matrix allograft was used as a substitute for palatal donor tissue. Probing depth, clinical attachment level, gingival recession, and width of keratinized tissue were measured two weeks prior to surgery and at six and 12 months post-surgery. There were no statistically significant differences between the groups in terms of recession reduction, clinical attachment gain, probing pocket depth, and increase in the width of the keratinized tissue after six or 12 months. There was no statistically significant increase in the width of keratinized tissue between six and 12 months for either group. Within the limitations of this study, it can be suggested that the acellular dermal matrix allograft may be a substitute for palatal donor tissue in root coverage procedures and that the time required for additional gain in the amount of keratinized tissue may be greater for the acellular dermal matrix than for the connective tissue procedures.
Aspiras, Marcelo B; Barros, Silvana P; Moss, Kevin L; Barrow, David A; Phillips, Sherrill T; Mendoza, Luis; de Jager, Marko; Ward, Marilyn; Offenbacher, Steven
2013-12-01
Investigate short-term effects of power brushing following experimental induction of biofilm overgrowth in periodontal disease states. Overall, 175 subjects representing each of five biofilm-gingival interface (BGI) periodontal groups were enrolled in a single-blind, randomized study. After stent-induced biofilm overgrowth for 21 days subjects received either a manual or a power toothbrush to use during a 4 weeks resolution phase. At baseline and during induction and resolution, standard clinical parameters were measured. Subclinical parameters included multikine analysis of 13 salivary biomarkers and 16s Human Oral Microbe Identification Microarray (HOMIM) probe analysis of subgingival plaque samples. All groups exhibited significantly greater reductions in bleeding on probing (BOP) (p = 0.002), gingival index (GI) (p = 0.0007), pocket depth (PD) (p = 0.04) and plaque index (p = 0.001) with power brushing compared to manual. When BGI groups were combined to form a shallow PD (PD ≤ 3 mm) and a deep PD group (PD > 4 mm) power brushing reduced BOP and GI in subjects with both pocket depths. Power brushing significantly reduced IL-1β levels at resolution while changes in bacterial levels showed non-significant trends between both brushing modalities. Short-term changes in select clinical parameters and subclinical salivary biomarkers may be useful in assessing efficacy of power brushing interventions in a spectrum of periodontal disease states. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
[Interest of ultrasonographic guidance in paediatric regional anaesthesia].
Dadure, C; Raux, O; Rochette, A; Capdevila, X
2009-10-01
The use of ultrasonographic guidance for regional anaesthesia has known recently a big interest in children in recent years. The linear ultrasound probes with a 25 mm active surface area (or probes with 38 mm active surface area in older children), with high sound frequencies in the range 8-14 MHz, allow a good compromise between excellent resolution for superficial structure and good penetration depths. In children, the easiest ultrasound guided blocks are axillar blocks, femoral blocks, fascia iliaca compartment blocks, ilio-inguinal blocks and para-umbilical blocks, caudal blocks. They permit a safe and easy learning curve of these techniques. The main advantage of ultrasound guided regional anaesthesia is the visualization of different anatomical structures and the approximate localization of the tip of needle. The other advantages for ultrasound guided peripheral nerve blocks in children are: faster onset time of sensory and motor block, longer duration of sensory blockade, increase of blockade quality and reduction of local anesthetic injection. The use of ultrasonographic guidance for central block allows to visualize different structures as well as spine and his content. Spinous process, ligament flavum, dura mater, conus medullaris and cerebrospinal fluid are identifiable, and give some information on spine, epidural space and the depth between epidural space and skin. At last, in caudal block, ultrasounds permit to evaluate the anatomy of caudal epidural space, especially the relation of the sacral hiatus to the dural sac and the search of occult spinal dysraphism. Benefit of this technique is the visualization of targeted nerves or spaces and the spread of injected local anaesthetic.
Intrauterine photoacoustic and ultrasound imaging probe
NASA Astrophysics Data System (ADS)
Miranda, Christopher; Barkley, Joel; Smith, Barbara S.
2018-04-01
Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a 2.92-mm diameter and approximate length of 26 cm, which allows for entry into the human endometrial cavity, making it possible to use photoacoustic imaging and high-resolution ultrasound to characterize the uterus. We demonstrate the imaging probes' ability to provide structural information of an excised pig uterus using ultrasound imaging and detect photoacoustic signals at a radial depth of 1 cm.
Efeoğlu, Ahmet; Hanzade, Mete; Sari, Esra; Alpay, Hande; Karakaş, Ozan; Koray, Fatma
2012-08-01
Treatment of gingival recessions has become one of the most challenging procedures in periodontal plastic surgery. Various surgical options with predictable outcomes are available, but in cases with cervical lesions or restorations, optimal functional and esthetic results may require the combination of periodontal and restorative procedures. In this case report, one patient treated with acellular dermal matrix allograft and a coronally positioned flap in combination with compomer cervical restorations is presented. Clinical parameters were recorded immediately prior to surgery and after 12 months. Postoperatively, significant root coverage, reductions in probing depths, and gains in clinical attachment were observed. The final clinical results, esthetics, color match, and tissue contours were acceptable to both the patient and clinicians.
Characterisation of a fibre optic Raman probe within a hypodermic needle.
Iping Petterson, Ingeborg E; Day, John C C; Fullwood, Leanne M; Gardner, Benjamin; Stone, Nick
2015-11-01
We demonstrate the first use of a multifibre Raman probe that fits inside the bore of a hypodermic needle. A Raman probe containing multiple collection fibres provides improved signal collection efficiency in biological samples compared with a previous two-fibre design. Furthermore, probe performance (signal-to-noise ratios) compared favourably with the performance achieved in previous Raman microscope experiments able to distinguish between benign lymph nodes, primary malignancies in lymph nodes and secondary malignancies in lymph nodes. The experimental measurements presented here give an indication of the sampling volume of the Raman needle probe in lymphoid tissues. Liquid tissue phantoms were used that contained scattering medium encompassing a range of scattering properties similar to those of a variety of tissue types, including lymph node tissues. To validate the appropriateness of the phantoms, the sampling depth of the probe was also measured in excised lymph node tissue. More than 50 % of Raman photons collected were found to originate from between the tip of the needle and a depth of 500 μm into the tissue. The needle probe presented here achieves spectral quality comparable to that in numerous studies previously demonstrating Raman disease discrimination. It is expected that this approach could achieve targeted subcutaneous tissue measurements and be viable for use for the in vivo Raman diagnostics of solid organs located within a few centimetres below the skin's surface. Graphical Abstract Schematic of multi-fibre Raman needle probe with disposible tips and proximal optical filtration.
Probing the inner space of resorcinarene molecular capsules with nitroxide guests.
Mileo, Elisabetta; Yi, Song; Bhattacharya, Papri; Kaifer, Angel E
2009-01-01
In quarantine: Nitroxide spin probes are encapsulated by hexameric resorcinarene molecular capsules in dichloromethane solutions (see picture). A substantial reduction in the tumbling rates occurs upon encapsulation of two cationic probes and one neutral probe. As the molecular volume of the probe increases, the tumbling rate of the probe reflects the overall tumbling rate of the entire supramolecular assembly.
Motion streaks in fast motion rivalry cause orientation-selective suppression.
Apthorp, Deborah; Wenderoth, Peter; Alais, David
2009-05-14
We studied binocular rivalry between orthogonally translating arrays of random Gaussian blobs and measured the strength of rivalry suppression for static oriented probes. Suppression depth was quantified by expressing monocular probe thresholds during dominance relative to thresholds during suppression. Rivalry between two fast motions or two slow motions was compared in order to test the suggestion that fast-moving objects leave oriented "motion streaks" due to temporal integration (W. S. Geisler, 1999). If fast motions do produce motion streaks, then fast motion rivalry might also entail rivalry between the orthogonal streak orientations. We tested this using a static oriented probe that was aligned either parallel to the motion trajectory (hence collinear with the "streaks") or was orthogonal to the trajectory, predicting that rivalry suppression would be greater for parallel probes, and only for rivalry between fast motions. Results confirmed that suppression depth did depend on probe orientation for fast motion but not for slow motion. Further experiments showed that threshold elevations for the oriented probe during suppression exhibited clear orientation tuning. However, orientation-tuned elevations were also present during dominance, suggesting within-channel masking as the basis of the extra-deep suppression. In sum, the presence of orientation-dependent suppression in fast motion rivalry is consistent with the "motion streaks" hypothesis.
Understanding of Jupiter's Atmosphere after the Galileo Probe Entry
NASA Technical Reports Server (NTRS)
Fonda, Mark (Technical Monitor); Young, Richard E.
2003-01-01
Instruments on the Galileo probe measured composition, cloud properties, thermal structure, winds, radiative energy balance, and electrical properties of the Jovian atmosphere. As expected the probe results confirm some expectations about Jupiter's atmosphere, refute others, and raise new questions which still remain unanswered. This talk will concentrate on those aspects of the probe observations which either raised new questions or remain unresolved. The Galileo probe observations of composition and clouds provided some of the biggest surprises of the mission. Helium abundance measured by the probe differed significantly from the remote sensing derivations from Voyager. Discrepancy between the Voyager helium abundance determinations for Jupiter and the Galileo probe value have now led to a considerably increased helium determination for Saturn. Global abundance of N in the form of ammonia was observed to be super-solar by approximately the same factor as carbon, in contrast to expectations that C/N would be significantly larger than solar. This has implications for the formation and evolution of Jupiter. The cloud structure was not what was generally anticipated, even though most previous remote sensing results below the uppermost cloud referred to 5 micron hot spots, local regions with reduced cloud opacity. The Galileo probe descended in one of these hot spots. Only a tenuous, presumed ammomium hydrosulfide, cloud was detected, and no significant water cloud or super-solar water abundance was measured. The mixing ratios as a function of depth for the condensibles ammonia, hydrogen sulfide, and water, exhibited no apparent correlation with either condensation levels or with each other, an observation that is still a puzzle, although there are now dynamical models of hot spots which show promise in being able to explain such behavior. Probe tracked zonal winds show that wind magnitude increases with depth to pressures of about 4 bars, with the winds extending to at least as deep as the probe made measurements, 22 bars. Models of hot spot dynamics raise the possibility that the variation with depth of the probe measured zonal winds between 0.4 and 4 bars reflect the dynamics of the hot spot rather than the global wind pattern. Galileo upper atmosphere measurements established that there is a sharp temperature rise with altitude between about 350 and 800 km above the 1 bar pressure level, with the upper atmosphere reaching temperatures near 900 K. The energy sources for this upper atmosphere heating are not clearly established, but various mechanisms have been proposed. These and other aspects of the Galileo probe data will be discussed.
Understanding of Jupiter's Atmosphere After the Galileo Probe Entry
NASA Technical Reports Server (NTRS)
Young, Richard E.; DeVincenzi, Donald (Technical Monitor)
2001-01-01
Instruments on the Galileo probe measured composition, cloud properties, thermal structure. winds, radiative energy balance, and electrical properties of the Jovian atmosphere. As expected the probe results confirm some expectations about Jupiter's atmosphere, refute others, and raise new questions which still remain unanswered. This talk will concentrate on those aspects of the probe observations which either raised new questions or remain unresolved. The Galileo probe observations of composition and clouds provided some of the biggest surprises of the mission. Helium abundance measured by the probe differed significantly from the remote sensing derivations from Voyager. discrepancy between the Voyager helium abundance determinations for Jupiter and the Galileo probe value have now led to a considerably increased helium determination for Saturn. Global abundance of N in the form of ammonia was observed to be supersolar by approximately the same factor as carbon, in contrast to expectations that C/N would be significantly larger than solar. This has implications for the formation and evolution of Jupiter. The cloud structure was not what was generally anticipated, even though most previous remote sensing results below the uppermost cloud referred to 5 micron hot spots, local regions with reduced cloud opacity. The Galileo probe descended in one of these hot spots. Only a tenuous, presumed ammonium hydrosulfide, cloud was detected, and no significant water cloud or super-solar water abundance was measured. The mixing ratios as a function of depth for the condensibles ammonia, hydrogen sulfide, and water, exhibited no apparent correlation with either condensation levels or with each other, an observation that is still a puzzle, although there are now dynamical models of hot spots which show promise in being able to explain such behavior. Probe tracked zonal winds show that wind magnitude increases with depth to pressures of about 4 bars, with the winds extending to at least as deep as the probe made measurements, 22 bars. Models of hot spot dynamics raise the possibility that the variation with depth of the probe measured zonal winds between 0.4 and 4 bars reflect the dynamics of the hot spot rather than the global wind pattern. Galileo upper atmosphere measurements established that there is a sharp temperature rise with altitude between about 350 and 800 km above the 1 bar pressure level, with the upper atmosphere reaching, temperatures near 900 K. The energy sources for this upper atmosphere heating are not clearly established, but various mechanisms have been proposed. These and other aspects of the Galileo probe data will be discussed.
Nondestructive testing and characterization of residual stress field using an ultrasonic method
NASA Astrophysics Data System (ADS)
Song, Wentao; Xu, Chunguang; Pan, Qinxue; Song, Jianfeng
2016-03-01
To address the difficulty in testing and calibrating the stress gradient in the depth direction of mechanical components, a new technology of nondestructive testing and characterization of the residual stress gradient field by ultrasonic method is proposed based on acoustoelasticity theory. By carrying out theoretical analysis, the sensitivity coefficients of different types of ultrasonic are obtained by taking the low carbon steel(12%C) as a research object. By fixing the interval distance between sending and receiving transducers, the mathematical expressions of the change of stress and the variation of time are established. To design one sending-one receiving and oblique incidence ultrasonic detection probes, according to Snell law, the critically refracted longitudinal wave (LCR wave) is excited at a certain depth of the fixed distance of the tested components. Then, the relationship between the depth of LCR wave detection and the center frequency of the probe in Q235 steel is obtained through experimental study. To detect the stress gradient in the depth direction, a stress gradient LCR wave detection model is established, through which the stress gradient formula is derived by the relationship between center frequency and detecting depth. A C-shaped stress specimen of Q235 steel is designed to conduct stress loading tests, and the stress is measured with the five group probes at different center frequencies. The accuracy of ultrasonic testing is verified by X-ray stress analyzer. The stress value of each specific depth is calculated using the stress gradient formula. Accordingly, the ultrasonic characterization of residual stress field is realized. Characterization results show that the stress gradient distribution is consistent with the simulation in ANSYS. The new technology can be widely applied in the detection of the residual stress gradient field caused by mechanical processing, such as welding and shot peening.
Patterns of entrapped air dissolution in a two-dimensional pilot-scale synthetic aquifer.
McLeod, Heather C; Roy, James W; Smith, James E
2015-01-01
Past studies of entrapped air dissolution have focused on one-dimensional laboratory columns. Here the multidimensional nature of entrapped air dissolution was investigated using an indoor tank (180 × 240 × 600 cm(3) ) simulating an unconfined sand aquifer with horizontal flow. Time domain reflectometry (TDR) probes directly measured entrapped air contents, while dissolved gas conditions were monitored with total dissolved gas pressure (PTDG ) probes. Dissolution occurred as a diffuse wedge-shaped front from the inlet downgradient, with preferential dissolution at depth. This pattern was mainly attributed to increased gas solubility, as shown by PTDG measurements. However, compression of entrapped air at greater depths, captured by TDR and leading to lower quasi-saturated hydraulic conductivities and thus greater velocities, also played a small role. Linear propagation of the dissolution front downgradient was observed at each depth, with both TDR and PTDG , with increasing rates with depth (e.g, 4.1 to 5.7× slower at 15 cm vs. 165 cm depth). PTDG values revealed equilibrium with the entrapped gas initially, being higher at greater depth and fluctuating with the barometric pressure, before declining concurrently with entrapped air contents to the lower PTDG of the source water. The observed dissolution pattern has long-term implications for a wide variety of groundwater management issues, from recharge to contaminant transport and remediation strategies, due to the persistence of entrapped air near the water table (potential timescale of years). This study also demonstrated the utility of PTDG probes for simple in situ measurements to detect entrapped air and monitor its dissolution. © 2014 Her Majesty the Queen in Right of Canada Groundwater © 2014, National Ground Water Association.
Mayrovitz, H N; Weingrad, D N; Brlit, F; Lopez, L B; Desfor, R
2015-03-01
An easily measured, non-invasive, quantitative estimate of local skin tissue water is useful to assess local lymphedema and its change. One method uses skin tissue dielectric constant (TDC) values that at 300 MHz TDC depend on free and bound water within the measurement volume. In practice such measurements have been done with a research-type multi-probe, but recently a hand-held compact-probe has become available that may be more clinically convenient. Because most available published data is based on multiprobe measurements it is important to characterize possible differences between devices that unless known might lead to ambiguous quantitative comparisons between TDC values. Thus, our purpose was to evaluate potential differences in measured TDC values between multi-probe and compact-probe devices with respect to probe effective sampling depth, anatomical site, and gender and also to compare compact-probe TDC values measured on women with and without breast cancer (BC). TDC was measured bilaterally on forearms and biceps of 32 male and 32 female volunteers and on 12 female patients awaiting surgery for breast cancer. Results show that 1) TDC values at 2.5 mm depth were significantly less than at 1.5 mm; 2) Female TDC values were significantly less than male values; 3) TDC values were not different between females with and without BC; and 4) dominant/non-dominant arm TDC ratios were not significantly different for any probe among genders or arm anatomical site. These findings indicate that probe type differences in absolute TDC values are present and should be taken into account when TDC values are compared. However, comparisons based on inter-arm TDC ratios are not statistically different among probes with respect to gender or anatomical location.
Nutrient availability at Mer Bleue bog measured by PRSTM probes
NASA Astrophysics Data System (ADS)
Wang, M.; Moore, T. R.; Talbot, J.
2015-12-01
Bogs, covering ~0.7 million km2 in Canada, store a large amount of C and N. As nutrient deficient ecosystems, it's critical to examine the nutrient availabilities and seasonal dynamics. We used Plant Root Simulators (PRSTM) at Mer Bleue bog to provide some baseline data on nutrient availability and its variability. In particular, we focused on ammonium, nitrate, phosphate, calcium, magnesium and potassium, iron, sulphate and aluminum. We placed PRS probes at a depth of 5 - 15 cm in pristine plots and plots with long term N, P and K fertilization for 4 weeks and determined the availability of these nutrients, from spring through to fall. Probes were also placed beneath the water table in hummock and hollow microtopography and along a transect including part of the bog which had been drained through the creation of a ditch 80 years ago. The result showed that there was limited available ammonium, nitrate and phosphate in the bog, the seasonal variation of nutrient availabilities probably due to mineralization, an increase in the availability of some nutrients between different water table depths or as a result of drainage, and the relative availability of nutrients compared to the input from fertilization. We suggest that PRS probes could be a useful tool to examine nutrient availability and dynamics in wetlands, with careful consideration of installing condition, for example, proper exposure period, depth relative to water table etc.
Kido, J; Nakamura, T; Kido, R; Ohishi, K; Yamauchi, N; Kataoka, M; Nagata, T
1999-10-01
Clinical and biochemical markers of periodontal disease have been used for precise objective diagnosis of periodontal inflammation. Interleukin 1beta (IL-1beta) and prostaglandin E2 (PGE2), inflammatory factors, levels in gingival crevicular fluid (GCF) of patients with periodontal disease are elevated and have been studied as biochemical markers. The levels of calprotectin, a leukocyte protein, in body fluids of patients with some inflammatory diseases are raised. Recently, we detected calprotectin in GCF and its concentrations in periodontal pockets were higher than those in healthy gingival crevices. In this study, we investigated the correlations between GCF calprotectin levels and clinical indicators (probing depth and bleeding on probing, BOP), and the IL-1beta or PGE2 levels in GCE Probing depth and BOP at 130 sites of 110 subjects with periodontal or other oral diseases were examined, then GCF samples were collected and their calprotectin, IL-1beta and PGE2 were determined by ELISA. The calprotectin level correlated positively with the probing depth and was significantly higher at BOP-positive than BOP-negative sites. There were significant, positive correlations between the calprotectin and IL-1beta or PGE2 concentrations. These results indicate that the calprotectin level in GCF correlates well with clinical and biochemical markers of periodontal disease and suggest that calprotectin may be useful for evaluating the extent of periodontal inflammation.
NASA Astrophysics Data System (ADS)
Sivasubramanian, Kathyayini; Periyasamy, Vijitha; Wen, Kew Kok; Pramanik, Manojit
2017-03-01
Photoacoustic tomography is a hybrid imaging modality that combines optical and ultrasound imaging. It is rapidly gaining attention in the field of medical imaging. The challenge is to translate it into a clinical setup. In this work, we report the development of a handheld clinical photoacoustic imaging system. A clinical ultrasound imaging system is modified to integrate photoacoustic imaging with the ultrasound imaging. Hence, light delivery has been integrated with the ultrasound probe. The angle of light delivery is optimized in this work with respect to the depth of imaging. Optimization was performed based on Monte Carlo simulation for light transport in tissues. Based on the simulation results, the probe holders were fabricated using 3D printing. Similar results were obtained experimentally using phantoms. Phantoms were developed to mimic sentinel lymph node imaging scenario. Also, in vivo sentinel lymph node imaging was done using the same system with contrast agent methylene blue up to a depth of 1.5 cm. The results validate that one can use Monte Carlo simulation as a tool to optimize the probe holder design depending on the imaging needs. This eliminates a trial and error approach generally used for designing a probe holder.
NASA Astrophysics Data System (ADS)
Aldrin, John C.; Hopkins, Deborah; Datuin, Marvin; Warchol, Mark; Warchol, Lyudmila; Forsyth, David S.; Buynak, Charlie; Lindgren, Eric A.
2017-02-01
For model benchmark studies, the accuracy of the model is typically evaluated based on the change in response relative to a selected reference signal. The use of a side drilled hole (SDH) in a plate was investigated as a reference signal for angled beam shear wave inspection for aircraft structure inspections of fastener sites. Systematic studies were performed with varying SDH depth and size, and varying the ultrasonic probe frequency, focal depth, and probe height. Increased error was observed with the simulation of angled shear wave beams in the near-field. Even more significant, asymmetry in real probes and the inherent sensitivity of signals in the near-field to subtle test conditions were found to provide a greater challenge with achieving model agreement. To achieve quality model benchmark results for this problem, it is critical to carefully align the probe with the part geometry, to verify symmetry in probe response, and ideally avoid using reference signals from the near-field response. Suggested reference signals for angled beam shear wave inspections include using the `through hole' corner specular reflection signal and the full skip' signal off of the far wall from the side drilled hole.
Clinical efficacy of subgingivally delivered simvastatin gel in chronic periodontitis patients.
Agarwal, Swati; Chaubey, Krishna Kumar; Chaubey, Abhinav; Agarwal, Vikas; Madan, Ellora; Agarwal, Manvi Chandra
2016-01-01
Simvastatin (SMV), a new locally delivered drug of class statins, is a specific competitive inhibitor of 3-hydroxy-2-methyl-glutaryl coenzyme A reductase. Statins, besides having lipid-lowering abilities, also have pleiotropic effects like host modulation and bone regeneration. The present study was designed to investigate the effectiveness of SMV, 1.2 mg, in an indigenously prepared biodegradable controlled-release gel as an adjunct to scaling and root planing (SRP). A total of 60 sites, with pocket depth ≥5 mm, two from each of 30 patients after SRP, were categorized into two treatment groups, for subgingival placement of placebo (Gp 1) or SMV (Gp 2). Clinical parameters were recorded at baseline and at 1, 3 and 6 months comprising plaque index, gingival index, probing pocket depth (PPD) and clinical attachment level (CAL). The osseous changes were evaluated radiographically by measuring vertical gain, INFRA 1 and angle of the defect, INFRA 2 from baseline to 6 months. All subjects tolerated the drug, without any post-application complication. The treatment improved the periodontal condition in both the groups but significant reductions in PPD (p= 0.04), and INFRA 1 (p= 0.000), along with gain in CAL (p= 0.02) and INFRA 2 (p= 0.000) were observed in Gp 2. In one site, an unexpected 5 mm decrease in INFRA 1 was found. Local drug delivery of SMV enhanced the beneficial effect of SRP, in pocket reduction, gain in CAL and bone fill.
Clinical efficacy of subgingivally delivered simvastatin gel in chronic periodontitis patients
Agarwal, Swati; Chaubey, Krishna Kumar; Chaubey, Abhinav; Agarwal, Vikas; Madan, Ellora; Agarwal, Manvi Chandra
2016-01-01
Background: Simvastatin (SMV), a new locally delivered drug of class statins, is a specific competitive inhibitor of 3-hydroxy-2-methyl-glutaryl coenzyme A reductase. Statins, besides having lipid-lowering abilities, also have pleiotropic effects like host modulation and bone regeneration. The present study was designed to investigate the effectiveness of SMV, 1.2 mg, in an indigenously prepared biodegradable controlled-release gel as an adjunct to scaling and root planing (SRP). Materials and Methods: A total of 60 sites, with pocket depth ≥5 mm, two from each of 30 patients after SRP, were categorized into two treatment groups, for subgingival placement of placebo (Gp 1) or SMV (Gp 2). Clinical parameters were recorded at baseline and at 1, 3 and 6 months comprising plaque index, gingival index, probing pocket depth (PPD) and clinical attachment level (CAL). The osseous changes were evaluated radiographically by measuring vertical gain, INFRA 1 and angle of the defect, INFRA 2 from baseline to 6 months. Results: All subjects tolerated the drug, without any post-application complication. The treatment improved the periodontal condition in both the groups but significant reductions in PPD (p= 0.04), and INFRA 1 (p= 0.000), along with gain in CAL (p= 0.02) and INFRA 2 (p= 0.000) were observed in Gp 2. In one site, an unexpected 5 mm decrease in INFRA 1 was found. Conclusion: Local drug delivery of SMV enhanced the beneficial effect of SRP, in pocket reduction, gain in CAL and bone fill. PMID:28298823
Berglundh, Tord; Armitage, Gary; Araujo, Mauricio G; Avila-Ortiz, Gustavo; Blanco, Juan; Camargo, Paulo M; Chen, Stephen; Cochran, David; Derks, Jan; Figuero, Elena; Hämmerle, Christoph H F; Heitz-Mayfield, Lisa J A; Huynh-Ba, Guy; Iacono, Vincent; Koo, Ki-Tae; Lambert, France; McCauley, Laurie; Quirynen, Marc; Renvert, Stefan; Salvi, Giovanni E; Schwarz, Frank; Tarnow, Dennis; Tomasi, Cristiano; Wang, Hom-Lay; Zitzmann, Nicola
2018-06-01
A classification for peri-implant diseases and conditions was presented. Focused questions on the characteristics of peri-implant health, peri-implant mucositis, peri-implantitis, and soft- and hard-tissue deficiencies were addressed. Peri-implant health is characterized by the absence of erythema, bleeding on probing, swelling, and suppuration. It is not possible to define a range of probing depths compatible with health; Peri-implant health can exist around implants with reduced bone support. The main clinical characteristic of peri-implant mucositis is bleeding on gentle probing. Erythema, swelling, and/or suppuration may also be present. An increase in probing depth is often observed in the presence of peri-implant mucositis due to swelling or decrease in probing resistance. There is strong evidence from animal and human experimental studies that plaque is the etiological factor for peri-implant mucositis. Peri-implantitis is a plaque-associated pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant mucosa and subsequent progressive loss of supporting bone. Peri-implantitis sites exhibit clinical signs of inflammation, bleeding on probing, and/or suppuration, increased probing depths and/or recession of the mucosal margin in addition to radiographic bone loss. The evidence is equivocal regarding the effect of keratinized mucosa on the long-term health of the peri-implant tissue. It appears, however, that keratinized mucosa may have advantages regarding patient comfort and ease of plaque removal. Case definitions in day-to-day clinical practice and in epidemiological or disease-surveillance studies for peri-implant health, peri-implant mucositis, and peri-implantitis were introduced. The proposed case definitions should be viewed within the context that there is no generic implant and that there are numerous implant designs with different surface characteristics, surgical and loading protocols. It is recommended that the clinician obtain baseline radiographic and probing measurements following the completion of the implant-supported prosthesis. © 2018 American Academy of Periodontology and European Federation of Periodontology.
Calcium antagonists and deep gingival pockets in the population-based SHIP study
Meisel, Peter; Schwahn, Christian; John, Ulrich; Kroemer, Heyo K; Kocher, Thomas
2005-01-01
Aim Gingival overgrowth is a common undesired side-effect in patients taking calcium channel blockers. Different reports have suggested that the drug-induced gingival hyperplasia may aggravate inflammatory periodontal disease. However, representative epidemiological data are lacking. We investigated the association between the intake of calcium antagonists and periodontitis in a population-based analysis including the most important risk factors of periodontitis. Methods In a cross-sectional epidemiological investigation involving 4290 subjects aged 20–80 years, we recorded periodontal risk factors and identified participants using calcium antagonists. Periodontal parameters, attachment loss, probing depth and number of teeth were assessed. In a subgroup analysis with matched pairs, 456 subjects using calcium antagonists and 456 without were compared for periodontal status. Results Subjects treated with calcium antagonistic drugs had significantly deeper gingival pockets than their drug-free counterparts. This was observed in the total population of 4290 and confirmed by logistic regression analyses (P < 0.001) controlled for the known risk factors of periodontitis (age, sex, smoking, education). In the matched-pair analysis only the probing depth was increased: extent probing depth ≥4 mm median 23.5 vs. 17.0% (P < 0.001); mean probing depth 3.0 ± 0.8 vs. 2.7 ± 0.9 mm (P < 0.001). No differences were found in extent and severity of clinical attachment loss and in the number of teeth. The risk of gingival overgrowth was aggravated in smokers. Conclusion In the general population, treatment with calcium antagonists leads to gingival overgrowth without an aggravation of periodontal disease. Interaction with smoking indicates the multifactorial background of the undesired effect of calcium antagonists. PMID:16236046
Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha
2008-01-01
Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (∼650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1–2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1–2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms. PMID:18697559
Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha
2008-07-01
Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5 x 10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (approximately 650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1-2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1-2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms.
Zijnge, Vincent; Meijer, Henriette F; Lie, Mady-Ann; Tromp, Jan A H; Degener, John E; Harmsen, Hermie J M; Abbas, Frank
2010-06-01
To test recolonization of periodontal lesions after full-mouth scaling and root planing (FM-SRP) or multiple session-SRP (MS-SRP) in a randomized clinical trial and whether FM-SRP and MS-SRP result in different clinical outcomes. Thirty-nine subjects were randomly assigned to FM-SRP or MS-SRP groups. At baseline and after 3 months, probing pocket depth (PPD), plaque index (PlI) and bleeding on probing (BoP) were recorded. At baseline, immediately after treatment, after 1, 2, 7, 14 and 90 days, paper point samples from a single site from the maxillary right quadrant were collected for microbiological analysis of five putative pathogens by polymerase chain reaction. FM-SRP and MS-SRP resulted in significant reductions in PPD, BoP and PlI and the overall detection frequencies of the five species after 3 months without significant differences between treatments. Compared with MS-SRP, FM-SRP resulted in less recolonization of the five species, significantly for Treponema denticola, in the tested sites. FM-SRP and MS-SRP result in overall clinically and microbiologically comparable outcomes where recolonization of periodontal lesions may be better prevented by FM-SRP.
Study of atomic coherence effects in multi-level V+Ξ system involving Rydberg state
NASA Astrophysics Data System (ADS)
Kaur, Amanjot; Singh, Neeraj; Kaur, Paramjit
2018-06-01
We present theoretical model to investigate the influence of hyperfine levels on the atomic coherences of V+Ξ Rydberg system. Using density matrix formulation, an analytical expression of atomic coherence for weak probe field is derived. The closely spaced hyperfine levels cause asymmetry and red shift while wavelength mismatching induced due to Rydberg state leads to reduction in magnitude and broadening of group index, absorption and dispersion profiles for moving atoms. Our system shows both Rydberg Electromagnetically induced transparency (EIT) with subluminal behavior and Rydberg Electromagnetically induced absorption (EIA) with superluminal propagation by adjusting the strengths of control and switching fields. Variation of group index with probe detuning reveals anomalous dispersion regions at Autler-Townes doublet positions. Group index for Doppler-broadened atoms at resonance condition has lower magnitude as compared to the stationary atoms and hence the group delay time of the pulse is also reduced. We also explore in-depth non-degenerate four-wave mixing (FWM) which is ignited due to the presence of three electromagnetic (e.m.) fields and concurrently, establish relationship between FWM and multi-photon atomic coherence. The transient behavior is also studied for practical realization of our considered system as optical switch.
Jönsson, B; Ohrn, K; Oscarson, N; Lindberg, P
2009-08-01
To describe and evaluate an individually tailored treatment programme based on a behavioural medicine approach to oral hygiene self-care for patients with chronic periodontitis. Two experimental single-case studies with multiple-baseline design across different self-administered oral hygiene behaviours were conducted. Cognitive Behavioural techniques were used to organize the strategies for the intervention and the approach to counselling was inspired by and structured in accordance with Motivational Interviewing. The central features in the programme were the individual analysis of knowledge and oral hygiene habits, individually set goals for oral hygiene behaviour, practice of manual dexterity for oral hygiene aids, continuous self-monitoring of the behaviour and prevention of relapse. Both participants reached the predecided criteria for clinical significance in reducing plaque and bleeding on probing. Reductions of periodontal probing depth were achieved as well. The positive results remained stable throughout the 2-year study period. The successful application of this educational model suggests that it could be used as a method for tailoring interventions targeted to oral hygiene for patients with periodontal conditions. The programme will now be tested in a larger randomized controlled trial.
The role of probiotic bacteria in managing periodontal disease: a systematic review.
Matsubara, Victor Haruo; Bandara, H M H N; Ishikawa, Karin Hitomi; Mayer, Marcia Pinto Alves; Samaranayake, Lakshman Perera
2016-07-01
The frequent recolonization of treated sites by periodontopathogens and the emergence of antibiotic resistance have led to a call for new therapeutic approaches for managing periodontal diseases. As probiotics are considered a new tool for combating infectious diseases, we systematically reviewed the evidences for their effectiveness in the management of periodontitis. An electronic search was performed in the MEDLINE, SCOPUS and Cochrane Library databases up to March 2016 using the terms 'periodontitis', 'chronic periodontitis', 'probiotic(s)', 'prebiotic(s)', 'symbiotic(s)', 'Bifidobacterium and 'Lactobacillus'. Only randomized controlled trials (RCTs) were included in the present study. Analysis of 12 RCTs revealed that in general, oral administration of probiotics improved the recognized clinical signs of chronic and aggressive periodontitis such as probing pocket depth, bleeding on probing, and attachment loss, with a concomitant reduction in the levels of major periodontal pathogens. Continuous probiotic administration, laced mainly with Lactobacillus species, was necessary to maintain these benefits. Expert commentary: Oral administration of probiotics is a safe and effective adjunct to conventional mechanical treatment (scaling) in the management of periodontitis, specially the chronic disease entity. Their adjunctive use is likely to improve disease indices and reduce the need for antibiotics.
NASA Astrophysics Data System (ADS)
Cordaro, S. W.; Bott-Suzuki, S. C.
2017-12-01
We present an experimental analysis of the symmetry of current density in a coaxial geometry, diagnosed using a magnetic field probe array and calculations of the Fowler-Nordheim enhancement factor. Data were collected on the coaxial gap breakdown device (240 A, 25 kV, 150 ns, ˜0.1 Hz), and data from experiments using 2 different gap sizes and different penetration depths are compared over runs comprising 50 shots for each case. The magnetic field probe array quantifies the distribution of current density at three axial locations, on either sides of a vacuum breakdown, and tracks the evolution with time and space. The results show asymmetries in current density, which can be influenced by changes in the gap size and the penetration depth (of the center electrode into the outer electrode). For smaller gap sizes (400 μm), symmetric current profiles were not observed, and the change in the penetration depth changes both the symmetric behavior of the current density and the enhancement factor. For larger gaps (900 μm), current densities were typically more uniform and less influenced by the penetration depth, which is reflected in the enhancement factor values. It is possible that the change in inductance caused by the localization of current densities plays a role in the observed behavior.
Fang, H; Han, M; Li, Q-L; Cao, C Y; Xia, R; Zhang, Z-H
2016-08-01
Scaling and root planing are widely considered as effective methods for treating chronic periodontitis. A meta-analysis published in 2008 showed no statistically significant differences between full-mouth disinfection (FMD) or full-mouth scaling and root planing (FMS) and quadrant scaling and root planing (Q-SRP). The FMD approach only resulted in modest additional improvements in several indices. Whether differences exist between these two approaches requires further validation. Accordingly, a study was conducted to further validate whether FMD with antiseptics or FMS without the use of antiseptics within 24 h provides greater clinical improvement than Q-SRP in patients with chronic periodontitis. Medline (via OVID), EMBASE (via OVID), PubMed and CENTRAL databases were searched up to 27 January 2015. Randomized controlled trials comparing FMD or FMS with Q-SRP after at least 3 mo were included. Meta-analysis was performed to obtain the weighted mean difference (WMD), together with the corresponding 95% confidence intervals. Thirteen articles were included in the meta-analysis. The WMD of probing pocket depth reduction was 0.25 mm (p < 0.05) for FMD vs. Q-SRP in single-rooted teeth with moderate pockets, and clinical attachment level gain in single- and multirooted teeth with moderate pockets was 0.33 mm (p < 0.05) for FMD vs. Q-SRP. Except for those, no statistically significant differences were found in the other subanalyses of FMD vs. Q-SRP, FMS vs. Q-SRP and FMD vs. FMS. Therefore, the meta-analysis results showed that FMD was better than Q-SRP for achieving probing pocket depth reduction and clinical attachment level gain in moderate pockets. Additionally, regardless of the treatment, no serious complications were observed. FMD, FMS and Q-SRP are all effective for the treatment of adult chronic periodontitis, and they do not lead to any obvious discomfort among patients. Moreover, FMD had modest additional clinical benefits over Q-SRP, so we prefer to recommend FMD as the first choice for the treatment of adult chronic periodontitis. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography
NASA Astrophysics Data System (ADS)
Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.
2004-10-01
A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-µm axial resolution by use of a femtosecond Crforsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.
Three-dimensional wide-field pump-probe structured illumination microscopy
Kim, Yang-Hyo; So, Peter T.C.
2017-01-01
We propose a new structured illumination scheme for achieving depth resolved wide-field pump-probe microscopy with sub-diffraction limit resolution. By acquiring coherent pump-probe images using a set of 3D structured light illumination patterns, a 3D super-resolution pump-probe image can be reconstructed. We derive the theoretical framework to describe the coherent image formation and reconstruction scheme for this structured illumination pump-probe imaging system and carry out numerical simulations to investigate its imaging performance. The results demonstrate a lateral resolution improvement by a factor of three and providing 0.5 µm level axial optical sectioning. PMID:28380860
NASA Astrophysics Data System (ADS)
Materne, Philipp; Kamusella, Sirko; Sarkar, Rajib; Goltz, Til; Spehling, Johannes; Maeter, Hemke; Harnagea, Luminita; Wurmehl, Sabine; Büchner, Bernd; Luetkens, Hubertus; Timm, Carsten; Klauss, Hans-Henning
2015-10-01
We present a detailed investigation of the magnetic and superconducting properties of Ca1 -xNaxFe2As2 single crystals with x =0.00 , 0.35, 0.50, and 0.67 by means of the local probe techniques Mössbauer spectroscopy and muon spin relaxation experiments. With increasing Na-substitution level, the magnetic order parameter is suppressed. For x =0.50 we find a microscopic coexistence of magnetic and superconducting phases accompanied by a reduction of the magnetic order parameter below the superconducting transition temperature Tc. A systematic comparison with other 122 pnictides reveals a square-root correlation between the reduction of the magnetic order parameter and the ratio of the transition temperatures Tc/TN , which can be understood in the framework of a Landau theory. In the optimally doped sample with Tc≈34 K, diluted magnetism is found and the temperature dependence of the penetration depth and superfluid density are obtained, proving the presence of two superconducting s -wave gaps.
Efficiency of nonsurgical periodontal therapy in moderate chronic periodontitis.
Mlachkova, Antoaneta M; Popova, Christina L
2014-01-01
Chronic periodontitis is defined as an inflammatory disease of the supporting tissues of teeth caused by microorganisms in the dental biofilm, resulting in progressive destruction of the periodontal ligament and alveolar bone with pocket formation and gingival recession. Treatment of chronic periodontitis aims at arresting the inflammation and stopping the loss of attachment by removal and control of the supra- and subgingival biofilm and establishing a local environment and microflora compatible with periodontal health. The AIM of this study was to evaluate the effectiveness of non-surgical therapy (scaling and root planning) in the treatment of moderate chronic periodontitis. The study included 30 patients aged between 33 and 75 years, of which 46.7% women and 53.3% men, diagnosed with moderate and, at some sites, severe periodontitis. They were treated with non-surgical periodontal therapy methods (scaling and root planning and curettage if indicated). Additionally, chemical plaque control with rinse water containing chlorhexidine was applied. The diagnostic and reassessment procedures included measuring the periodontal indices of 601 periodontal units before and after the therapy. The indices measured were the papillary bleeding index (PBI), the hygiene index (HI), the probing pocket depth (PPD) and the clinical attachment level (CAL). Significant reduction of plaque and gingival inflammation was found in all treated patients; we also found a statistically significant reduction of periodontal pockets with clinically measured depth < 5 mm (PD < 5 mm). Pockets with PD > 5 mm did not show statistically significant lower incidence rates probably due to the initially small percentage of deep pockets in the patients studied. There was a statistically significant reduction of all sites with attachment loss, the highest significance found at sites where the attachment loss was greater than 5 mm. The results of the study suggest that nonsurgical periodontal therapy is effective in managing the moderate chronic periodontitis. Given a good patient compliance, the antimicrobial periodontal therapy can be quite efficient in arresting the inflammatory process and reducing the depth of periodontal pockets; it can also achieve a stable attachment loss level and obviate the need to use a surgical periodontal treatment modality.
Zhang, Yiman; Kirshenbaum, Kevin C.; Marschilok, Amy C.; ...
2017-05-11
The formation of conductive metallic silver upon electrochemical reduction and lithiation of Ag 7Fe 3(P 2O 7) 4 is investigated. Alternating current impedance spectroscopy measurements show a 34% decrease in charge transfer resistance upon one electron equivalent (ee) of reduction, which is coincident with the formation of a Ag metal conductive network evidenced by both ex situ and operando X-ray diffraction. Quantitative assessment of Ag metal formation derived from operando XRD shows that only Ag + ions are reduced during the first 3ee, followed by simultaneous reduction of Ag + and Fe 3+ reduction for the next 5ee (3ee tomore » 8ee), culminating in reduction of the remaining Ag +. Scanning electron microscopy images show smaller Ag metal crystallite size and shorter nearest neighbor distance between and among Ag particles with higher depth of discharge. A high rate intermittent pulsatile discharge test is conducted where the cell delivers 12 total pulses during full discharge to probe the effect of Ag metal formation on the Li/Ag 7Fe 3(P 2O 7) 4 cell electrochemistry. The Ohmic resistance is derived from the voltage drop of each pulse. The resistance is 65 Ω initially, reaches its minimum of 26 Ω at 4.5 ee discharge, and levels off at 35 Ω after 7.0 ee reduction. In conclusion, the initial Ag reduction is more significant for the conductive network formation indicated by the decrease of both R ct and Ohmic resistance, which facilitates the high power output of the cell.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yiman; Kirshenbaum, Kevin C.; Marschilok, Amy C.
The formation of conductive metallic silver upon electrochemical reduction and lithiation of Ag 7Fe 3(P 2O 7) 4 is investigated. Alternating current impedance spectroscopy measurements show a 34% decrease in charge transfer resistance upon one electron equivalent (ee) of reduction, which is coincident with the formation of a Ag metal conductive network evidenced by both ex situ and operando X-ray diffraction. Quantitative assessment of Ag metal formation derived from operando XRD shows that only Ag + ions are reduced during the first 3ee, followed by simultaneous reduction of Ag + and Fe 3+ reduction for the next 5ee (3ee tomore » 8ee), culminating in reduction of the remaining Ag +. Scanning electron microscopy images show smaller Ag metal crystallite size and shorter nearest neighbor distance between and among Ag particles with higher depth of discharge. A high rate intermittent pulsatile discharge test is conducted where the cell delivers 12 total pulses during full discharge to probe the effect of Ag metal formation on the Li/Ag 7Fe 3(P 2O 7) 4 cell electrochemistry. The Ohmic resistance is derived from the voltage drop of each pulse. The resistance is 65 Ω initially, reaches its minimum of 26 Ω at 4.5 ee discharge, and levels off at 35 Ω after 7.0 ee reduction. In conclusion, the initial Ag reduction is more significant for the conductive network formation indicated by the decrease of both R ct and Ohmic resistance, which facilitates the high power output of the cell.« less
Sulcular debridement with pulsed Nd:YAG
NASA Astrophysics Data System (ADS)
Harris, David M.; Gregg, Robert H., II; McCarthy, Delwin K.; Colby, Leigh E.; Tilt, Lloyd V.
2002-06-01
We present data supporting the efficacy of the procedure, laser sulcular debridement (laser curettage), as an important component in the treatment of inflammatory periodontal disease. Laser Assisted New Attachment Procedure (LANAP) is a detailed protocol for the private practice treatment of gum disease that incorporates use of the PerioLase pulsed Nd:YAG Dental Laser for laser curettage. Laser curettage is the removal of diseased or inflamed soft tissue from the periodontal pocket with a surgical dental laser. The clinical trial conducted at The University of Texas HSC at San Antonio, Texas, evaluated laser curettage as an adjunct to scaling and root planing. They measured traditional periodontal clinical indices and used a questionnaire to evaluate patient comfort and acceptance. The Texas data (N=10 patients) are compared with pocket depth changes following LANAP. LANAP data were obtained from a retrospective review of patient records at three private practices (N=65). No significant differences in post treatment probe depth changes were found among the four centers indicating that the procedure produced consistent, favorable outcomes, and that results from controlled scientific clinical trials can be replicated in private practices. Reduction in pocket depths following laser treatment compare well with results obtained with scalpel surgery. The use of the laser offers additional benefits. We also present quantitative evidence from digitized radiographs of increased bone density in affected areas following LANAP.
A new temperature profiling probe for investigating groundwater-surface water interaction
Naranjo, Ramon C.; Robert Turcotte,
2015-01-01
Measuring vertically nested temperatures at the streambed interface poses practical challenges that are addressed here with a new discrete subsurface temperature profiling probe. We describe a new temperature probe and its application for heat as a tracer investigations to demonstrate the probe's utility. Accuracy and response time of temperature measurements made at 6 discrete depths in the probe were analyzed in the laboratory using temperature bath experiments. We find the temperature probe to be an accurate and robust instrument that allows for easily installation and long-term monitoring in highly variable environments. Because the probe is inexpensive and versatile, it is useful for many environmental applications that require temperature data collection for periods of several months in environments that are difficult to access or require minimal disturbance.
A bio-impedance probe to assess liver steatosis during transplant surgery.
Smith, Penny Probert; You, Fusheng; Vogel, Thomas; Silva, Michael
2011-01-01
This work addresses the design of a bioimpedance probe to assess steatosis on the exposed liver in the donor during liver transplant surgery. Whereas typically bioimpedance uses needle probes to avoid surface effects, for clinical reasons a non-penetrative probe is required. In addition the need to ensure that the measurement is representative of the bulk tissue suggests a larger probe than is normally used to ensure a sufficiently large measurement volume. Using a simple model, simulations and tests on bovine liver, this paper investigates the relationship between probe dimensions and depth of measurement penetration and investigates the accuracy which might be expected in a configuration suitable for use in the operating theatre on intact but exposed livers. A probe using ECG electrodes is proposed and investigated.
3D-atom probe characterization of nano-precipitates in a PM processed tool steels
NASA Astrophysics Data System (ADS)
Niederkofler, M.; Leisch, M.
2004-07-01
The microstructure of a powder metallurgical processed high speed steel (nom. composition (wt.%): 1.6 C, 4.8 Cr, 2.0 Mo, 5.0 V, 105 W, 8.0 Co and balance Fe) has been examined using 3D-atom probe technique. By the depth profiling of the time to flight mass spectrometer and position sensitive recording, cylindrical volumes of 10-15 nm in diameter and up to 40 nm in depth have been probed and characterized. The depth profiling measurements of the samples show generally a very homogeneous structure which was expected by the powder metallurgical processing of the material. Different morphologies of the precipitates were recorded. Besides the needle shaped precipitates with an extend up to 20 nm and thickness of few atomic layers, platelets and spherical particles are observed as well. The species which can be assigned to the precipitates appear to some extend as MC molecules in the mass histogram, while the leading constituents in this MC are Mo, V and Cr. Beside distinct particles agglomerations like one-dimensional atomic chains of the alloy components are also observed in the 3D reconstructions of the tool steel matrix.
On the electron vortex beam wavefunction within a crystal.
Mendis, B G
2015-10-01
Electron vortex beams are distorted by scattering within a crystal, so that the wavefunction can effectively be decomposed into many vortex components. Using a Bloch wave approach equations are derived for vortex beam decomposition at any given depth and with respect to any frame of reference. In the kinematic limit (small specimen thickness) scattering largely takes place at the neighbouring atom columns with a local phase change of π/2rad. When viewed along the beam propagation direction only one vortex component is present at the specimen entrance surface (i.e. the 'free space' vortex in vacuum), but at larger depths the probe is in a mixed state due to Bragg scattering. Simulations show that there is no direct correlation between vortex components and the 〈Lz〉 pendellösung, i.e. at a given depth probes with relatively constant 〈Lz〉 can be in a more mixed state compared to those with more rapidly varying 〈Lz〉. This suggests that minimising oscillations in the 〈Lz〉 pendellösung by probe channelling is not the only criterion for generating a strong electron energy loss magnetic circular dichroism (EMCD) signal. Copyright © 2015 Elsevier B.V. All rights reserved.
Genuine binding energy of the hydrated electron
Luckhaus, David; Yamamoto, Yo-ichi; Suzuki, Toshinori; Signorell, Ruth
2017-01-01
The unknown influence of inelastic and elastic scattering of slow electrons in water has made it difficult to clarify the role of the solvated electron in radiation chemistry and biology. We combine accurate scattering simulations with experimental photoemission spectroscopy of the hydrated electron in a liquid water microjet, with the aim of resolving ambiguities regarding the influence of electron scattering on binding energy spectra, photoelectron angular distributions, and probing depths. The scattering parameters used in the simulations are retrieved from independent photoemission experiments of water droplets. For the ground-state hydrated electron, we report genuine values devoid of scattering contributions for the vertical binding energy and the anisotropy parameter of 3.7 ± 0.1 eV and 0.6 ± 0.2, respectively. Our probing depths suggest that even vacuum ultraviolet probing is not particularly surface-selective. Our work demonstrates the importance of quantitative scattering simulations for a detailed analysis of key properties of the hydrated electron. PMID:28508051
NASA Technical Reports Server (NTRS)
Hecht, Michael; Carsey, Frank
2005-01-01
The subsurface ice probe (SIPR) is a proposed apparatus that would bore into ice to depths as great as hundreds of meters by melting the ice and pumping the samples of meltwater to the surface. Originally intended for use in exploration of subsurface ice on Mars and other remote planets, the SIPR could also be used on Earth as an alternative to coring, drilling, and melting apparatuses heretofore used to sample Arctic and Antarctic ice sheets. The SIPR would include an assembly of instrumentation and electronic control equipment at the surface, connected via a tether to a compact assembly of boring, sampling, and sensor equipment in the borehole (see figure). Placing as much equipment as possible at the surface would help to attain primary objectives of minimizing power consumption, sampling with high depth resolution, and unobstructed imaging of the borehole wall. To the degree to which these requirements would be satisfied, the SIPR would offer advantages over the aforementioned ice-probing systems.
Interpreting Neutron Probe Readings In Frozen Soil
Richard S. Sartz
1969-01-01
Several factors associated with soil freezing complicate the interpretation of neutron probe readings in frozen soil. Temperature is unimportant, but the effect of vertical resolution must be considered. Because of the possibility of both gains and losses of water at the same depth during a period of measurement, interpreting changes in the water content of frozen...
Yoon, Jihyung; Xie, Yibo; Zhang, Rui
2018-03-01
The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Monte Carlo simulations within avalanche rescue
NASA Astrophysics Data System (ADS)
Reiweger, Ingrid; Genswein, Manuel; Schweizer, Jürg
2016-04-01
Refining concepts for avalanche rescue involves calculating suitable settings for rescue strategies such as an adequate probing depth for probe line searches or an optimal time for performing resuscitation for a recovered avalanche victim in case of additional burials. In the latter case, treatment decisions have to be made in the context of triage. However, given the low number of incidents it is rarely possible to derive quantitative criteria based on historical statistics in the context of evidence-based medicine. For these rare, but complex rescue scenarios, most of the associated concepts, theories, and processes involve a number of unknown "random" parameters which have to be estimated in order to calculate anything quantitatively. An obvious approach for incorporating a number of random variables and their distributions into a calculation is to perform a Monte Carlo (MC) simulation. We here present Monte Carlo simulations for calculating the most suitable probing depth for probe line searches depending on search area and an optimal resuscitation time in case of multiple avalanche burials. The MC approach reveals, e.g., new optimized values for the duration of resuscitation that differ from previous, mainly case-based assumptions.
Laser measure of sea salinity, temperature and turbidity in depth
NASA Technical Reports Server (NTRS)
Hirschberg, J. G.; Wouters, A. W.; Byrne, J. D.
1974-01-01
A method is described in which a pulsed laser is used to probe the sea. Backscattered light is analyzed in time, intensity and wavelength. Tyndall, Raman and Brillouin scattering are used to obtain the backscatter turbidity, sound velocity, salinity, and the temperature as a function of depth.
NASA Astrophysics Data System (ADS)
Belfield, Kevin D.; Yao, Sheng; Kim, Bosung; Yue, Xiling
2016-03-01
Imaging biological samples with two-photon fluorescence (2PF) microscopy has the unique advantage of resulting high contrast 3D resolution subcellular image that can reach up to several millimeters depth. 2PF probes that absorb and emit at near IR region need to be developed. Two-photon excitation (2PE) wavelengths are less concerned as 2PE uses wavelengths doubles the absorption wavelength of the probe, which means 2PE wavelengths for probes even with absorption at visible wavelength will fall into NIR region. Therefore, probes that fluoresce at near IR region with high quantum yields are needed. A series of dyes based on 5-thienyl-2, 1, 3-benzothiadiazole and 5-thienyl-2, 1, 3-benzoselenadiazole core were synthesized as near infrared two-photon fluorophores. Fluorescence maxima wavelengths as long as 714 nm and fluorescence quantum yields as high as 0.67 were achieved. The fluorescence quantum yields of the dyes were nearly constant, regardless of solvents polarity. These diazoles exhibited large Stokes shift (<114nm), high two-photon absorption cross sections (up to 2,800 GM), and high two-photon fluorescence figure of merit (FM , 1.04×10-2 GM). Cells incubated on a 3D scaffold with one of the new probes (encapsulated in Pluronic micelles) exhibited bright fluorescence, enabling 3D two-photon fluorescence imaging to a depth of 100 µm.
Müller, H P; Barrieshi-Nusair, K M
2007-09-01
The aim of this study was to investigate the possible association of a distinct combination of polymorphisms in the interleukin (IL)-1 gene cluster on gingival bleeding tendency in young adult Arabs with plaque-induced gingivitis. Fifty otherwise healthy, nonsmoking volunteers, 19-28 years of age, participated. Clinical examinations included periodontal probing depth, bleeding on probing, and plaque index. Probing was done with a pressure-controlled probe at about 1.27 MPa. Examinations were repeated after 2 and 4 weeks. Polymorphisms in the IL-1 gene cluster were assessed using a reverse hybridization assay. A subject carrying alleles 2 at IL-1A ( -889 ) and IL-1B ( +3954 ) was designated genotype-positive. Twenty-six subjects were genotype-positive (52%). A repeated measures two-level (occasion, subject) model of the proportion of sites bleeding on probing, which was adjusted for gender, average plaque index, probing depth, and calculus, revealed a significantly lower proportion of bleeding sites in genotype-positive subjects (estimate -0.050, standard error 0.025, p < 0.05). Biserial correlations of bleeding proportions were high (0.71-0.78), confirming the steady-state plaque environment. It was concluded that inflammatory responses to dental plaque were considerably dampened in genotype-positive, nonsmoking young adults of Arabic heritage.
GHIZONI, Janaina Salomon; TAVEIRA, Luís Antônio de Assis; GARLET, Gustavo Pompermaier; GHIZONI, Marcos Flávio; PEREIRA, Jefferson Ricardo; DIONÍSIO, Thiago José; BROZOSKI, Daniel Thomas; SANTOS, Carlos Ferreira; SANT'ANA, Adriana Campos Passanezi
2012-01-01
Objective: This study investigated the role of periodontal disease in the development of stroke or cerebral infarction in patients by evaluating the clinical periodontal conditions and the subgingival levels of periodontopathogens. Material and Methods: Twenty patients with ischemic (I-CVA) or hemorrhagic (H-CVA) cerebrovascular episodes (test group) and 60 systemically healthy patients (control group) were evaluated for: probing depth, clinical attachment level, bleeding on probing and plaque index. Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were both identified and quantified in subgingival plaque samples by conventional and real-time PCR, respectively. Results: The test group showed a significant increase in each of the following parameters: pocket depth, clinical attachment loss, bleeding on probing, plaque index and number of missing teeth when compared to control values (p<0.05, unpaired t-test). Likewise, the test group had increased numbers of sites that were contaminated with P. gingivalis (60%x10%; p<0.001; chi-squared test) and displayed greater prevalence of periodontal disease, with an odds ratio of 48.06 (95% CI: 5.96-387.72; p<0.001). Notably, a positive correlation between probing depth and the levels of P. gingivalis in ischemic stroke was found (r=0.60; p=0.03; Spearman's rank correlation coefficient test). A. actinomycetemcomitans DNA was not detected in any of the groups by conventional or real-time PCR. Conclusions: Stroke patients had deeper pockets, more severe attachment loss, increased bleeding on probing, increased plaque indexes, and in their pockets harbored increased levels of P. gingivalis. These findings suggest that periodontal disease is a risk factor for the development of cerebral hemorrhage or infarction. Early treatment of periodontitis may counteract the development of cerebrovascular episodes. PMID:22437687
Integration of CubeSat Systems with Europa Surface Exploration Missions
NASA Astrophysics Data System (ADS)
Erdoǧan, Enes; Inalhan, Gokhan; Kemal Üre, Nazım
2016-07-01
Recent studies show that there is a high probability that a liquid ocean exists under thick icy surface of Jupiter's Moon Europa. The findings also show that Europa has features that are similar to Earth, such as geological activities. As a result of these studies, Europa has promising environment of being habitable and currently there are many missions in both planning and execution level that target Europa. However, these missions usually involve extremely high budgets over extended periods of time. The objective of this talk is to argue that the mission costs can be reduced significantly by integrating CubeSat systems within Europa exploration missions. In particular, we introduce an integrated CubeSat-micro probe system, which can be used for measuring the size and depth of the hypothetical liquid ocean under the icy surface of Europa. The systems consist of an entry module that houses a CubeSat combined with driller measurement probes. Driller measurement probes deploy before the system hits the surface and penetrate the surface layers of Europa. Moreover, a micro laser probe could be used to examine the layers. This process enables investigation of the properties of the icy layer and the environment beneath the surface. Through examination of different scenarios and cost analysis of the components, we show that the proposed CubeSat systems has a significant potential to reduce the cost of the overall mission. Both subsystem requirements and launch prices of CubeSats are dramatically cheaper than currently used satellites. In addition, multiple CubeSats may be used to dominate wider area in space and they are expandable in face of potential failures. In this talk we discuss both the mission design and cost reduction aspects.
Morales, Alicia; Gandolfo, Alessandro; Bravo, Joel; Carvajal, Paola; Silva, Nora; Godoy, Claudia; Garcia-Sesnich, Jocelyn; Hoare, Anilei; Diaz, Patricia; Gamonal, Jorge
2018-01-01
ABSTRACT Objective The aim of this double-blind, placebo-controlled and parallel- arm randomized clinical trial was to evaluate the effects of Lactobacillus rhamnosus SP1-containing probiotic sachet and azithromycin tablets as an adjunct to nonsurgical therapy in clinical parameters and in presence and levels of Tannerella forsythia, Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans. Material and Methods Forty-seven systemically healthy volunteers with chronic periodontitis were recruited and monitored clinically and microbiologically at baseline for 3, 6 and 9 months after therapy. Subgingival plaque samples were collected from four periodontal sites with clinical attachment level ≥1 mm, probing pocket depth ≥4 mm and bleeding on probing, one site in each quadrant. Samples were cultivated and processed using the PCR technique. Patients received nonsurgical therapy including scaling and root planing (SRP) and were randomly assigned to a probiotic (n=16), antibiotic (n = 16) or placebo (n = 15) group. L. rhamnosus SP1 was taken once a day for 3 months. Azithromycin 500mg was taken once a day for 5 days. Results All groups showed improvements in clinical and microbiological parameters at all time points evaluated. Probiotic and antibiotic groups showed greater reductions in cultivable microbiota compared with baseline. The placebo group showed greater reduction in number of subjects with P. gingivalis compared with baseline. However, there were no significant differences between groups. Conclusions The adjunctive use of L. rhamnosus SP1 sachets and azithromycin during initial therapy resulted in similar clinical and microbiological improvements compared with the placebo group. PMID:29364340
Changes in Periodontal Parameters and C-Reactive Protein After Pregnancy.
Raga, Lucía Gil; Mínguez, Ignacio; Caffesse, Raul; Llambés, Fernando
2016-12-01
This study assesses hormonal, inflammatory, and periodontal changes in pregnant women and postpartum in the absence of periodontal treatment, and seeks to determine any correlations among these parameters. A longitudinal, observational study of 117 pregnant women (aged 23 to 42 years) was undertaken in a private gynecologic center between weeks 32 and 35 of pregnancy and 6 to 8 weeks after delivery. Levels of progesterone and C-reactive protein (CRP) in plasma were determined, as well as periodontal indices, including: 1) plaque index (PI); 2) bleeding on probing (BOP); 3) probing depth (PD); and 4) clinical attachment level (CAL). Postpartum progesterone and CRP declined sharply from 90.85 ± 42.51 ng/mL and 3.73 ± 4.01 mg/L to 0.77 ± 1.43 ng/mL and 1.43 ± 1.67 mg/L, respectively. There was also a significant improvement in all periodontal indices (P <0.05) with the exception of PI. During pregnancy mean BOP was 21.03%, mean PD 2.62 mm, and mean CAL 1.20 mm. After delivery mean BOP was 13.25%, mean PD 2.39 mm, and mean CAL 1.14 mm. Percentage of 1- to 3-mm pockets increased (P <0.05), while 4- to 5-mm pockets and pockets >6 mm decreased significantly (P <0.001). Reduction in CRP correlated significantly with decrease in BOP (P <0.001). Postpartum, there was a dramatic reduction in progesterone and CRP, together with an improvement in BOP, PD, and CAL in the absence of periodontal treatment. Decrease in CRP was related to an improvement in periodontal bleeding.
Nonsurgical treatment of moderate and advanced periimplantitis lesions: a controlled clinical study.
Schwarz, Frank; Bieling, Katrin; Bonsmann, Martin; Latz, Thilo; Becker, Jürgen
2006-12-01
The aim of this controlled, parallel design clinical study was to evaluate the effectiveness of an Er:YAG (erbium-doped:yttrium, aluminum, and garnet) laser for nonsurgical treatment of periimplantitis lesions. Twenty patients, each of whom displayed at least one implant with (a) moderate and (b) advanced periimplantitis (n=40 implants; IMZ, ITI, Spline Twist, ZL-Duraplant, Camlog), were randomly instrumented nonsurgically using either (1) an Er:YAG laser (100 mJ/pulse, 10 Hz) device (LAS) or (2) mechanical debridement using plastic curettes and antiseptic therapy with chlorhexidine digluconate (0.2%) (C). The following clinical parameters were measured at baseline, 3, 6, and 12 months after treatment: plaque index, bleeding on probing (BOP), probing depth, gingival recession, and clinical attachment level (CAL). Mean BOP improved significantly in both groups at 3, 6, and 12 months (a- lesions: P<0.001 and b- lesions: P<0.01, respectively). After 3 and 6 months, the mean reduction of BOP was significantly higher in the LAS group when compared to the C group (a- and b- lesions: P<0.01 and P<0.05, respectively). At 3 and 6 months, both groups revealed significant CAL gains at a- and b- lesions (P<0.01, respectively). In both groups, however, the mean CAL at a- and b- lesions was not significantly different from the respective baseline values at 12 months (P>0.05, respectively). Although treatment of periimplantitis lesions with LAS resulted in a significantly higher BOP reduction than C, its effectiveness seemed to be limited to a period of 6 months, particularly at b- lesions.
Nogueira-Filho, G R; Peruzzo, D; Sallum, A W
2008-03-01
This aim of this study was to evaluate the relationship between the formation of volatile sulfur compounds (VSC) and the severity of different kinds of periodontal disease. Twenty patients suffering from biofilm-related periodontal diseases and a control group of ten healthy individuals were selected. The patients were divided according to their periodontal diagnoses: marginal gingivitis (MG/n = 10) and chronic periodontitis (CP/n = 10). The patients received non-surgical therapy that consisted of motivation, scaling and root planing. Two experimental periods were used: T1 = baseline and T2 = final evaluation after three months. The data analysis showed that CP group had a significant reduction (p < 0.05) in probing depth (PD) and clinical attachment level (CAL), and group MG presented a reduction in GI (p < 0.05). There was a significant reduction (p < 0.05) in the aspartate aminotransferase (AST), N-a-benzoyl-DL-arginine-p-nitroanilide (BAPNA) and VSC levels in both MG and CP groups, although the deeper residual pockets led to higher AST and VSC levels in the CP group. Within the limits of the present pilot study, it can be concluded that the non-surgical therapy may influence VSC formation in a manner dependent on periodontal disease severity.
Mailoa, James; Lin, Guo-Hao; Chan, Hsun-Liang; MacEachern, Mark; Wang, Hom-Lay
2014-09-01
The aim of this systematic review is to compare the clinical outcomes of lasers with other commonly applied detoxification methods for treating peri-implantitis. An electronic search of four databases and a hand search of peer-reviewed journals for relevant articles were conducted. Comparative human clinical trials and case series with ≥ 6 months of follow-up in ≥ 10 patients with peri-implantitis treated with lasers were included. Additionally, animal studies applying lasers for treating peri-implantitis were also included. The included studies had to report probing depth (PD) reduction after the therapy. Seven human prospective clinical trials and two animal studies were included. In four and three human studies, lasers were accompanied with surgical and non-surgical treatments, respectively. The meta-analyses showed an overall weighted mean difference of 0.00 mm (95% confidence interval = -0.18 to 0.19 mm) PD reduction between the laser and conventional treatment groups (P = 0.98) for non-surgical intervention. In animal studies, laser-treated rough-surface implants had a higher percentage of bone-to-implant contact than smooth-surface implants. In a short-term follow-up, lasers resulted in similar PD reduction when compared with conventional implant surface decontamination methods.
Woelber, J P; Bremer, K; Vach, K; König, D; Hellwig, E; Ratka-Krüger, P; Al-Ahmad, A; Tennert, C
2016-07-26
The aim of this pilot study was to investigate the effects of four weeks of an oral health optimized diet on periodontal clinical parameters in a randomized controlled trial. The experimental group (n = 10) had to change to a diet low in carbohydrates, rich in Omega-3 fatty acids, and rich in vitamins C and D, antioxidants and fiber for four weeks. Participants of the control group (n = 5) did not change their dietary behavior. Plaque index, gingival bleeding, probing depths, and bleeding upon probing were assessed by a dentist with a pressure-sensitive periodontal probe. Measurements were performed after one and two weeks without a dietary change (baseline), followed by a two week transitional period, and finally performed weekly for four weeks. Despite constant plaque values in both groups, all inflammatory parameters decreased in the experimental group to approximately half that of the baseline values (GI: 1.10 ± 0.51 to 0.54 ± 0.30; BOP: 53.57 to 24.17 %; PISA: 638 mm(2) to 284 mm(2)). This reduction was significantly different compared to that of the control group. A diet low in carbohydrates, rich in Omega-3 fatty acids, rich in vitamins C and D, and rich in fibers can significantly reduce gingival and periodontal inflammation. German Clinical Trials Register; https://www.germanctr.de (DRKS00006301). Registered on 2015-02-21.
Strong negative terahertz photoconductivity in photoexcited graphene
NASA Astrophysics Data System (ADS)
Fu, Maixia; Wang, Xinke; Ye, Jiasheng; Feng, Shengfei; Sun, Wenfeng; Han, Peng; Zhang, Yan
2018-01-01
Terahertz (THz) response of a chemical vapor deposited graphene on a quartz substrate has been investigated by using an ultrafast optical-pump THz-probe spectroscopy. Without photoexcitation, the frequency-dependence optical conductivity shows a strong carrier response owing to the intrinsically doped graphene. Upon photoexcitation, an enhancement in THz transmission is observed and the transmission increases nonlinearly with the increase of pump power, which is rooted in a reduction of intrinsic conductivity arising from the strong enhancement of carrier scattering rather than THz emission occurrence. The modulation depth of 18.8% was experimentally achieved, which is more than four times greater than that of the previous reported. The photoinduced response here highlights the variety of response possible in graphene depending on the sample quality, carrier mobility and doping level. The graphene provides promising applications in high-performance THz modulators and THz photoelectric devices.
Pozo, P; Valenzuela, M A; Melej, C; Zaldívar, M; Puente, J; Martínez, B; Gamonal, J
2005-06-01
The aim of this work was to improve the assessment of the periodontal disease status through measurements of extracellular matrix metalloproteinases (MMPs) and their tissular inhibitors (TIMPs) in the gingival crevicular fluid from patients diagnosed with chronic periodontitis. Gingival crevicular fluid samples from patients (n = 13) were taken from 60 sites initially, and from 51 and 41 sites, respectively, 3 and 6 months after scaling and root planing. Gingival crevicular fluid samples were also taken from healthy subjects (n = 11, 24 sites). The presence of MMP-9 and MMP-8 was assessed by zymography and immunowestern blotting, respectively. The actual MMP activity (gelatinase and collagenase) was measured using the fluorogenic substrate assay. TIMP-1 and -2 levels were measured by immunodot blot. The fluorogenic substrate assay determinations showed higher MMP activity in sites with probing depth > or = 4 mm, with significant reduction post-treatment. Gelatinase activity followed by zymography consisted mainly of MMP-9. A different pattern of MMP-8 in control and patient sites was found. Controls only showed species of a partially active form (69 kDa), whereas patient sites showed a high frequency of the active form (56 kDa), and in some cases the latent form (85 kDa) was also observed. The active form reduced its frequency in sites with probing depth > or = 4 mm. TIMP-1 and -2 levels in patients were significantly lower than in controls, and after treatment the recovery of TIMP-1 level similar to control was observed. Significant correlations between the severity of the periodontal disease and the actual MMP activity, the active form of MMP-8 and the low level of both TIMP-1 and TIMP-2 were found.
Nasra, Maha M A; Khiri, Heba M; Hazzah, Heba A; Abdallah, Ossama Y
2017-11-01
This study aimed to develop syringeable in-situ curcumin (cur) gel for the treatment of periodontal pockets as well as to evaluate the clinical efficacy of Cur in-situ gel formulation. Different in-situ gel formulations of Cur were prepared using 30% of pluronic F127, and 1% of carbopol P934. The formulations were evaluated regarding gelation temperature, pH, viscosity, syringeability study, in-vitro release and chemical stability of cur. The effect of aging of gel formulations for 3months in refrigerator was investigated. The selected formulation was clinically evaluated through the determination of probing depth, plaque index, and bleeding index at baseline and 1 month after application. The formulations showed accepted gelation temperature ranging from 28 to 34 °C and all had pH value of 4. The viscosity of the formulations at 4 °C ranged from 19 000 to 37 000 cP. All formulations were easily syringeable through 21 gauge needle at cold temperature. Curcumin stability during the release study was maintained. Aging showed no significant effect on release profile, drug content, or the pH after 3 months, while it showed a slight increase in viscosity with concomitant decrease in gelation temperature. Selected formulations delivered into periodontal pocket evaluated clinically showed to be effective. The treated group revealed that the adjunctive use of intracrevicular 2% curcumin in-situ gel adjunct to mechanical treatment in patients with adult periodontitis could aid in significant clinical reduction of probing depth, bleeding index, and to less extent of plaque. This indicates that curcumin in this novel drug delivery system is an excellent candidate for periodontal disease treatment.
Nelson, S W
2001-10-01
Recent histological evidence has documented that grafted palatal connective tissue is capable of forming a new attachment to previously exposed roots in the treatment of gingival recession. No clinical studies have tested the ability of connective tissue that has been implanted beneath the periosteum into periodontal osseous defects to reduce probing depth and increase clinical attachment levels. This study reports the long-term clinical effect of subperiosteal and intraosseous connective tissue grafts on deep periodontal pockets. Connective tissue (CT) grafts were placed in 32 periodontal pockets on 27 patients. Grafts were classified into 3 groups. Type I grafts had 50% or more vascular surface contact and were < or = 2.5 mm thick. Type II grafts had 50% or more contact but were > 2.5 mm thick, and Type III grafts had less than 50% vascular contact regardless of thickness. Twelve of 14 Type I sites, 9 of 15 Type II sites, and 3 of 3 Type III sites were analyzed 9 to 13 years following treatment. Clinical attachment level change differed significantly between the graft types on survivor teeth (P < 0.05): Type III had 2 mm loss (95% confidence interval [CI]: 0.4 to 3.6), while Type II and Type I grafts had a 2.7 mm gain (95% CI: 2.0 to 3.4) and 4.3 mm gain (95% CI: 3.3 to 5.2), respectively. Similar substantial differences were presented for changes in probing depth and recession. This long-term (9 to 13 years) retrospective case-series analysis suggests substantial improvements in periodontal clinical measures for Type I CT grafts in deep periodontal pockets. Randomized trials are required to evaluate this promising procedure.
Synthetic aperture imaging in ultrasound calibration
NASA Astrophysics Data System (ADS)
Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Jayaranthe, Uditha L.; Chen, Elvis C. S.; Peters, Terry M.
2014-03-01
Ultrasound calibration allows for ultrasound images to be incorporated into a variety of interventional applica tions. Traditional Z- bar calibration procedures rely on wired phantoms with an a priori known geometry. The line fiducials produce small, localized echoes which are then segmented from an array of ultrasound images from different tracked probe positions. In conventional B-mode ultrasound, the wires at greater depths appear blurred and are difficult to segment accurately, limiting the accuracy of ultrasound calibration. This paper presents a novel ultrasound calibration procedure that takes advantage of synthetic aperture imaging to reconstruct high resolution ultrasound images at arbitrary depths. In these images, line fiducials are much more readily and accu rately segmented, leading to decreased calibration error. The proposed calibration technique is compared to one based on B-mode ultrasound. The fiducial localization error was improved from 0.21mm in conventional B-mode images to 0.15mm in synthetic aperture images corresponding to an improvement of 29%. This resulted in an overall reduction of calibration error from a target registration error of 2.00mm to 1.78mm, an improvement of 11%. Synthetic aperture images display greatly improved segmentation capabilities due to their improved resolution and interpretability resulting in improved calibration.
Construction and evaluation of an inexpensive weighing lysimeter for studying contaminant transport
NASA Astrophysics Data System (ADS)
Corwin, D. L.; LeMert, R. D.
1994-01-01
A description is provided of an above-ground, weighing lysimeter that minimizes the edge flow of water which can occur between the soil and the wall of the casing. The lysimeter was designed to study water flux and the movement of inorganic and/or organic pollutants as they pass through and beyond the root zone. The lysimeter is instrumented at selected depths with thermistors, soil solution extractors, time-domain reflectometry probes, gas extractors and tensiometers. These sensors provide temperature measurements, soil solution samples, water content measurements, soil atmosphere samples and water potential measurements. The horizontal insertion of these instruments from the side of the lysimeter reduces and channeling that might occur along the sides of the instruments, if they had been inserted vertically. Annular-ring baffles are located at selected depths to reduce edge flow between the lysimeter casing and the column of soil. The baffles redirect water flow away from the edge of the column. Data are presented that show a reduction in the hydraulic bypass of the lysimeter compared to a lysimeter without baffles. The total cost of a single lysimeter including materials and labor is under US $4000.
NASA Astrophysics Data System (ADS)
Falub, C. V.; Mijnarends, P. E.; Eijt, S. W.; van Huis, M. A.; van Veen, A.; Schut, H.
2002-08-01
Quantum-confined positrons are sensitive probes for determining the electronic structure of nanoclusters embedded in materials. In this work, a depth-selective positron annihilation 2D-ACAR (two-dimensional angular correlation of annihilation radiation) method is used to determine the electronic structure of Li nanoclusters formed by implantation of 1016-cm-2 30-keV 6Li ions in MgO (100) and (110) crystals and by subsequent annealing at 950 K. Owing to the difference between the positron affinities of lithium and MgO, the Li nanoclusters act as quantum dots for positrons. 2D-ACAR distributions for different projections reveal a semicoherent fitting of the embedded metallic Li nanoclusters to the host MgO lattice. Ab initio Korringa-Kohn-Rostoker calculations of the momentum density show that the anisotropies of the experimental distributions are consistent with an fcc crystal structure of the Li nanoclusters. The observed reduction of the width of the experimental 2D-ACAR distribution is attributed to positron trapping in vacancies associated with Li clusters. This work proposes a method for studying the electronic structure of metallic quantum dots embedded in an insulating material.
Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.
Herz, P R; Chen, Y; Aguirre, A D; Schneider, K; Hsiung, P; Fujimoto, J G; Madden, K; Schmitt, J; Goodnow, J; Petersen, C
2004-10-01
A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-microm axial resolution by use of a femtosecond Cr:forsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.
Al-Anezi, Saud A.
2015-01-01
Introduction Orthodontic bands cause periodontal inflammation. In theory, the use of a buccal tube (bond) instead of a band should prevent or minimize periodontal changes because the bonds are positioned away from the gingival margins. Objective The primary aim of this study was to investigate the periodontal status of orthodontic bands compared with bonds in the first three months of orthodontic treatment. Materials and methods Twenty-four orthodontic patients (mean age = 12.6 years) were enrolled in this Randomized Controlled Trial (RCT). Using the cross-mouth technique, bands and bonds were used in opposite quadrants. Periodontal parameters including the presence or absence of Bleeding On Probing (BOP) and Probing Depths (PDs) were taken at the start and three months into treatment. Results Bands caused a statistically significant change in the Bleeding On Probing (BOP) (P = 0.001 and 0.021) and bonds displayed a statistically insignificant change in the Bleeding On Probing (BOP) (P = 0.125 and 1.00) for the upper and lower arch. The difference in Probing Depths (PDs) between bands and bonds was also statistically significant (P = 0.001). Conclusion Molar bands are associated with greater periodontal inflammation compared with molar bonds in the first three months of fixed orthodontic treatment. PMID:26236124
NASA Astrophysics Data System (ADS)
Brunner, D.; Kuang, A. Q.; LaBombard, B.; Burke, W.
2017-07-01
A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enable self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. In addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.
Planetary Atmosphere Dynamics and Radiative Transfer
NASA Technical Reports Server (NTRS)
Atkinson, David H.
1996-01-01
This research program has dealt with two projects in the field of planetary atmosphere dynamics and radiative energy transfer, one theoretical and one experimental. The first project, in radiative energy transfer, incorporated the capability to isolate and quantify the contribution of individual atmospheric components to the Venus radiative balance and thermal structure to greatly improve the current understanding of the radiative processes occurring within the Venus atmosphere. This is possible by varying the mixing ratios of each gas species, and the location, number density and aerosol size distributions of the clouds. This project was a continuation of the work initiated under a 1992 University Consortium Agreement. Under the just completed grant, work has continued on the use of a convolution-based algorithm that provided the capability to calculate the k coefficients of a gas mixture at different temperatures, pressures and spectral intervals from the separate k-distributions of the individual gas species. The second primary goal of this research dealt with the Doppler wind retrieval for the Successful Galileo Jupiter probe mission in December, 1995. In anticipation of the arrival of Galileo at Jupiter, software development continued to read the radioscience and probe/orbiter trajectory data provided by the Galileo project and required for Jupiter zonal wind measurements. Sample experiment radioscience data records and probe/orbiter trajectory data files provided by the Galileo Radioscience and Navigation teams at the Jet Propulsion Laboratory, respectively, were used for the first phase of the software development. The software to read the necessary data records was completed in 1995. The procedure by which the wind retrieval takes place begins with initial consistency checks of the raw data, preliminary data reductions, wind recoveries, iterative reconstruction of the probe descent profile, and refined wind recoveries. At each stage of the wind recovery consistency is checked and maintained between the orbiter navigational data, the radioscience data, and the probe descent profile derived by the Atmospheric Instrument Team. Preliminary results show that the zonal winds at Jupiter increase with depth to approximately 150 m/s.
Mercado, Faustino; Hamlet, Stephen; Ivanovski, Saso
2018-05-16
There is limited evidence regarding the long-term efficacy of regenerative treatment for peri-implantitis. The aim of this study was to evaluate a combination therapy of deproteinized bovine bone mineral with 10% collagen (DBBMC), enamel matrix derivative (EMD) and Doxycycline in the regeneration of bone defects associated with peri-implantitis. Thirty patients diagnosed with peri-implantitis (BoP/suppuration, probing depth greater than 4 mm, minimum radiographic bone loss of 20%, at least 2 years in function) were enrolled in the study. Clinical measurements included probing depths, recession, radiographic bone fill, gingival inflammation and bleeding on probing/suppuration. Following surgical access and debridement, the implant surfaces were decontaminated with 24% EDTA for 2 min, and the bone defects were filled with a combined mixture of DBBMC, EMD and Doxycycline powder. The defects were covered with connective tissue grafts where necessary. Clinical measurements were recorded after 12, 24 and 36 months. The mean probing depth and bone loss at the initial visit was 8.9 mm (±1.9) and 6.92 mm (±1.26), respectively. Both mean probing depth and bone loss reduced significantly from baseline to 3.55 mm (±0.50) and 2.85 mm (±0.73) at 12 months, 3.50 (±0.50) and 2.62 mm (±0.80) at 24 months and 3.50 mm (±0.50) and 2.60 mm (±0.73) at 36 months. 56.6% of the implants were considered successfully treated (according to Successful Treatment Outcome Criterion: PD < 5 mm, no further bone loss >10%, no BoP/suppuration, no recession >0.5 mm for anterior implants and >1.5 mm for posterior implants) after 36 months. Regenerative treatment of peri-implantitis using a combined mixture of DBBMC, EMD and Doxycycline achieved promising results. The benefits of this protocol incorporating EMD should be tested in randomized clinical trials. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Periodontal status during pregnancy and postpartum.
González-Jaranay, Maximino; Téllez, Luís; Roa-López, Antonio; Gómez-Moreno, Gerardo; Moreu, Gerardo
2017-01-01
Different studies have documented an association between periodontal disease and low birth-weight delivery. Hence, knowledge of periodontal status during pregnancy and postpartum is important in order to reduce the risks of both diseases. This study aimed to analyze periodontal status at successive stages of pregnancy and 3-6 weeks postpartum in women with initial periodontal alterations. Ninety-six pregnant women were examined at 8-10 weeks (pregnancy diagnosis, baseline), 21-23 weeks and 34-36 weeks of gestation and at 40 days postpartum to record plaque scores, clinically assessed gingival inflammation and probing depth (mean depth and % sites with depth >3 mm). Bivariate and multivariate analyses were performed. Type 1 (α) error was established at 0.05. Plaque Index increased (p = 0.043) throughout pregnancy (baseline, 42%±0.18); 21-23 weeks, 42.6%±0.14; 34-36 weeks, 45.6%±0.13 and decreased postpartum (44.8%±0-13). Gingival Index increased (p<0.001) throughout pregnancy (baseline, 56.7%±0.20; 21-23 weeks, 66.36%±0.17; 34-36 weeks, 74.5%±0.18) and decreased postpartum (59.3%±0.21). Probing Depth increased (p<0.001) throughout pregnancy (baseline, 2.51±0.05; 21-23 weeks, 2.63±0.053; 34-36 weeks 2.81±0.055) and decreased postpartum (2.54±0.049). Percentage of sites with Probing Depth >3 mm increased (p<0.001) throughout pregnancy (baseline, 17.6%±0.16; 21-23 weeks, 23.9%±0.17; 34-36 weeks, 31.1%±0.17) and decreased postpartum (21.2%±0.17) but remained significantly (p<0.02) higher than at baseline. Periodontal status deteriorates during gestation but improves postpartum.
ERIC Educational Resources Information Center
Saba, Shahrokh; Cagino, Kristen; Bennett, Caitlin
2015-01-01
A pedagogically useful discovery-based undergraduate organic chemistry lab experiment probing the chemo- and diastereoselectivity in the NaBH[subscript 4] reduction of two chiral ketoesters (benzoin acetate and benzoin benzoate) has been developed. This experiment complements a previously described and highly popular discovery-based experiment…
Auger Spectroscopy Analysis of Spalled LEU-10Mo Foils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawrence, Samantha Kay; Schulze, Roland K.
2017-08-03
Presentation includes slides on Surface Science used to probe LEU-10Mo Spall; Auger highlights graphitic-like inclusions and Mo-deficient oxide on base metal; Higher C concentration detected within spall area Images Courtesy; Depth profiling reveals thick oxide; Mo concentration nears nominal only at depths ~400 nm; and lastly Key Findings.
Konugolu Venkata Sekar, S; Mosca, S; Tannert, S; Valentini, G; Martelli, F; Binzoni, T; Prokazov, Y; Turbin, E; Zuschratter, W; Erdmann, R; Pifferi, A
2018-05-01
We present a time domain diffuse Raman spectrometer for depth probing of highly scattering media. The system is based on, to the best of our knowledge, a novel time-correlated single-photon counting (TCSPC) camera that simultaneously acquires both spectral and temporal information of Raman photons. A dedicated non-contact probe was built, and time domain Raman measurements were performed on a tissue mimicking bilayer phantom. The fluorescence contamination of the Raman signal was eliminated by early time gating (0-212 ps) the Raman photons. Depth sensitivity is achieved by time gating Raman photons at different delays with a gate width of 106 ps. Importantly, the time domain can provide time-dependent depth sensitivity leading to a high contrast between two layers of Raman signal. As a result, an enhancement factor of 2170 was found for our bilayer phantom which is much higher than the values obtained by spatial offset Raman spectroscopy (SORS), frequency offset Raman spectroscopy (FORS), or hybrid FORS-SORS on a similar phantom.
Wavelet analysis of poorly-focused ultrasonic signal of pressure tube inspection in nuclear industry
NASA Astrophysics Data System (ADS)
Zhao, Huan; Gachagan, Anthony; Dobie, Gordon; Lardner, Timothy
2018-04-01
Pressure tube fabrication and installment challenges combined with natural sagging over time can produce issues with probe alignment for pressure tube inspection of the primary circuit of CANDU reactors. The ability to extract accurate defect depth information from poorly focused ultrasonic signals would reduce additional inspection procedures, which leads to a significant time and cost saving. Currently, the defect depth measurement protocol is to simply calculate the time difference between the peaks of the echo signals from the tube surface and the defect from a single element probe focused at the back-wall depth. When alignment issues are present, incorrect focusing results in interference within the returning echo signal. This paper proposes a novel wavelet analysis method that employs the Haar wavelet to decompose the original poorly focused A-scan signal and reconstruct detailed information based on a selected high frequency component range within the bandwidth of the transducer. Compared to the original signal, the wavelet analysis method provides additional characteristic defect information and an improved estimate of defect depth with errors less than 5%.
Pneumatic Proboscis Heat-Flow Probe
NASA Technical Reports Server (NTRS)
Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant
2013-01-01
Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.
Edwards, Ryland B; Lu, Yan; Rodriguez, Edwin; Markel, Mark D
2002-04-01
To compare cartilage matrix temperatures between monopolar radiofrequency energy (mRFE) and bipolar RFE (bRFE) at 3 depths under the articular surface during thermal chondroplasty. We hypothesized that cartilage temperatures would be higher at all cartilage depths for the bRFE device than for the mRFE device. Randomized trial using bovine cartilage. Sixty osteochondral sections from the femoropatellar joint of 15 adult cattle were used for this study. Using a custom jig, fluoroptic thermometry probes were placed at one of the following depths under the articular surface: 200 microm, 500 microm, or 2,000 microm. RF treatment was performed either with fluid flow (F) (120 mL/min) or without fluid flow (NF) (n = 5/depth/RFE device/flow; total specimens, 60). Irrigation fluid temperature was room temperature (22 degrees C). Thermometry data were acquired at 4 Hz for 5 seconds with the RF probe off, for 20 seconds with the RF probe on, and then for 15 seconds with the RF probe off. During RF treatment, a 0.79-cm2 area (1.0-cm diameter) of the articular surface centered over the thermometry probe was treated in a paintbrush manner in noncontact (bRFE) or light contact (mRFE). Thermal chondroplasty with bRFE resulted in higher cartilage matrix temperatures compared with mRFE for all depths and regardless of fluid flow. Bipolar RFE resulted in temperatures of 95 degrees C to 100 degrees C at 200 microm and 500 microm under the surface, with temperatures of 75 degrees C to 78 degrees C at 2,000 microm. Fluid flow during bRFE application had no effect at 200 microm. Monopolar RFE resulted in temperatures of 61 degrees C to 68 degrees C at 200 microm, 54 degrees C to 70 degrees C at 500 microm under the surface, and 28 degrees C to 30 degrees C at 2,000 microm below the surface. A significant effect of fluid flow during mRFE application occurred at 200 microm (NF, 61 degrees C; F, 63 degrees C) and 500 microm (NF, 53 degrees C; F, 68 degrees C). In this study, we found significant differences between bRFE and a temperature-controlled mRFE device with regard to depth of thermal heating of cartilage in vitro. Bipolar RFE resulted in matrix temperatures high enough (>70 degrees C) to kill cells as deep as 2,000 microm under the articular surface. Fluid flow during thermal chondroplasty had the effect of significantly increasing cartilage matrix temperatures at 200 and 500 microm with the mRFE device. During thermal chondroplasty, bRFE creates greater matrix temperature elevations at equivalent depths and treatment duration than does mRFE. Excessive temperatures generated deep within the cartilage matrix could cause full-thickness chondrocyte death, in vivo.
NASA Astrophysics Data System (ADS)
Sawazaki, K.; Saito, T.; Ueno, T.; Shiomi, K.
2015-12-01
In this study, utilizing depth-sensitivity of interferometric waveforms recorded by co-located Hi-net and KiK-net sensors, we separate the responsible depth of seismic velocity change associated with the M6.3 earthquake occurred on November 22, 2014, in central Japan. The Hi-net station N.MKGH is located about 20 km northeast from the epicenter, where the seismometer is installed at the 150 m depth. At the same site, the KiK-net has two strong motion seismometers installed at the depths of 0 and 150 m. To estimate average velocity change around the N.MKGH station, we apply the stretching technique to auto-correlation function (ACF) of ambient noise recorded by the Hi-net sensor. To evaluate sensitivity of the Hi-net ACF to velocity change above and below the 150 m depth, we perform a numerical wave propagation simulation using 2-D FDM. To obtain velocity change above the 150 m depth, we measure response waveform from the depths of 150 m to 0 m by computing deconvolution function (DCF) of earthquake records obtained by the two KiK-net vertical array sensors. The background annual velocity variation is subtracted from the detected velocity change. From the KiK-net DCF records, the velocity reduction ratio above the 150 m depth is estimated to be 4.2 % and 3.1 % in the periods of 1-7 days and 7 days - 4 months after the mainshock, respectively. From the Hi-net ACF records, the velocity reduction ratio is estimated to be 2.2 % and 1.8 % in the same time periods, respectively. This difference in the estimated velocity reduction ratio is attributed to depth-dependence of the velocity change. By using the depth sensitivity obtained from the numerical simulation, we estimate the velocity reduction ratio below the 150 m depth to be lower than 1.0 % for both time periods. Thus the significant velocity reduction and recovery are observed above the 150 m depth only, which may be caused by strong ground motion of the mainshock and following healing in the shallow ground.
Stein, Jamal M; Hammächer, Christian; Michael, Sareh Said-Yekta
2017-12-05
The aim of this study is to evaluate clinical outcomes of a concept for non-surgical peri-implantitis combining stepwise mechanical debridement measures with adjuvant povidone-iodine application with and without systemic antibiotics. Forty-five patients with chronic periodontitis and a total of 164 screw-typed implants with peri-implantitis were included. Peri-implantitis was defined as radiographic bone loss of > 2 mm, probing depth (PD) ≥5 mm with bleeding on probing (BOP). Stepwise treatment of implants was performed with ultrasonic debridement, soft tissue curettage (STC), glycine powder air polishing (GPAP), and a repeated submucosal application of povidone-iodine. Teeth with PD > 4 mm were treated simultaneously according to the same concept except STC. In cases with severe periodontitis (n = 24), amoxicillin and metronidazole (AM) were prescribed for 7 days. After 12 months, implants treated without AM showed significant reductions (P < 0.05) of mean PD (1.4 ± 0.7 mm), clinical attachment level (CAL) (1.3 ± 0.8 mm), and BOP (33.4% ± 17.2%). In deep pockets (PD > 6 mm) changes of mean PD (2.3 ± 1.3 mm), CAL (2.0 ± 1.6 mm), and BOP (44.0% ± 41.7%) were more pronounced. Intake of AM did not significantly influence the changes in these parameters. However, the reduction of implant sites with PD > 4 mm and BOP was significantly higher in patients with AM than in those without AM (31.8% ± 12.6% versus 20.8% ± 14.7%; P < 0.05). The combination of ultrasonic debridement, STC, and GPAP with adjuvant povidone-iodine led to significant clinical improvements at implants. Systemic antibiotics had limited effects on the reduction of persisting implant sites with treatment need. © 2017 American Academy of Periodontology.
Roos-Jansåker, Ann-Marie; Almhöjd, Ulrica S; Jansson, Henrik
2017-01-01
To evaluate the adjunctive clinical effects of a chloramine to non-surgical treatment of peri-implantitis. Eighteen individuals diagnosed with peri-implantitis (clinical signs of inflammation and progressive bone loss) on at least two implants were included. Clinical variables; plaque accumulation (Pl), probing depth (PD), clinical attachment level (CAL) and bleeding on probing (BoP), were recorded at baseline and at 3-month follow-up. Primary clinical efficacy variable was the change in the number of sites with BoP. The implants were randomized into two different treatment groups: test and control. Both implants received supra- and submucosal debridement by ultrasonic instrumentation supplemented with hand instruments. The implants assigned to the test group first received local applications of a chloramine gel (Perisolv ™ ; RLS Global AB, Gothenburg, Sweden) followed by mechanical instrumentation. The oral hygiene was checked at 6 weeks. After 3 months, implants of both groups showed statistically significant reduction (P < 0.001) in the number of BoP-positive sites compared with baseline. The reduction of BoP-positive sites in the test group changed from 0.97 (SD ± 0.12) to 0.38 (SD ± 0.46), and in the control group from 0.97 (SD ± 0.12) to 0.31 (SD ± 0.42). Between-group comparisons revealed no statistically significant differences at baseline and after 3 months, for BoP or any of the other variables. In the present randomized clinical trial of peri-implantitis therapy; non-surgical mechanical debridement with adjunctive use of a chloramine is equally effective in the reduction of mucosal inflammation as conventional non-surgical mechanical debridement up to 3 months. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
John, Gordon; Sahm, Narja; Becker, Jürgen; Schwarz, Frank
2015-11-01
The purpose of this prospective, parallel group-designed, randomized controlled clinical study was the evaluation of the effectiveness of an air-abrasive device (AAD) for nonsurgical treatment of peri-implantitis. Twenty five patients, showing at least one implant with initial to moderate peri-implantitis, underwent an oral hygiene programme and were randomly treated using either (1) AAD (amino acid glycine powder) or (2) mechanical debridement using carbon curettes and antiseptic therapy with chlorhexidine digluconate (mechanical debridement (MDA)). Clinical parameters were measured at baseline and 12 months after treatment (e.g. bleeding on probing (BOP), probing depth (PD), clinical attachment level (CAL)). At 12 months, the AAD group revealed significantly higher (p < 0.05; unpaired t test) decrease in mean BOP scores when compared with MDA-treated sites (41.2 ± 29.5 vs. 16.6 ± 33.4%). Both groups exhibited comparable PD reductions (AAD = 0.5 ± 0.9 mm vs. MDA = 0.4 ± 0.9 mm) and CAL gains (AAD = 0.6 ± 1.3 mm vs. MDA = 0.5 ± 1.1 mm) (p > 0.05; Mann-Whitney test, respectively). Within its limitations, the present study has indicated that both treatment procedures resulted in comparable but limited CAL gains at 12 months. Furthermore, it could be detected that AAD was associated with significantly higher BOP decrease than MDA. The present results have indicated that nonsurgical therapy of peri-implantitis using both AAD and MDA resulted in comparable PD reductions and CAL gains after 12 months of healing. The BOP reductions were significantly higher in the AAD in comparison to the MDA group. So, AAD may be more effective for nonsurgical therapy of peri-implantitis than MDA.
Fercher, A; Hitzenberger, C; Sticker, M; Zawadzki, R; Karamata, B; Lasser, T
2001-12-03
Dispersive samples introduce a wavelength dependent phase distortion to the probe beam. This leads to a noticeable loss of depth resolution in high resolution OCT using broadband light sources. The standard technique to avoid this consequence is to balance the dispersion of the sample byarrangingadispersive materialinthereference arm. However, the impact of dispersion is depth dependent. A corresponding depth dependent dispersion balancing technique is diffcult to implement. Here we present a numerical dispersion compensation technique for Partial Coherence Interferometry (PCI) and Optical Coherence Tomography (OCT) based on numerical correlation of the depth scan signal with a depth variant kernel. It can be used a posteriori and provides depth dependent dispersion compensation. Examples of dispersion compensated depth scan signals obtained from microscope cover glasses are presented.
Jenabian, Niloofar; Bahabadi, Mohadese Yazdanpanah; Bijani, Ali; Rad, Morteza Rahimi
2016-01-01
Objectives: Gingival recession can lead to root exposure and discomfort for patients. There are various techniques for root coverage. The aim of this study was to compare the use of gingival unit graft (palatal graft including the marginal gingiva and papillae) with free gingival graft for treatment of localized gingival recession. Materials and Methods: In this randomized controlled clinical trial, 18 bilateral localized recessions of Miller class I and II were treated in nine systemically healthy patients. Recessions were randomly treated with gingival unit graft in one side and conventional free gingival graft in the other side. Clinical parameters including clinical attachment level, keratinized tissue width, probing depth and vertical recession depth (VRD) were recorded at baseline and at one, three and six months after surgery. The healing index and patient satisfaction were also evaluated. One-way and two-way repeated measures ANOVA and paired t-test were used for statistical analyses. Results: Both techniques caused significant improvement in clinical parameters. Gingival unit graft produced higher satisfaction esthetically (P=0.050, 0.024 and 0.024, respectively at the three time points), higher healing index (P<0.001), higher root coverage percentage at one month after surgery (34.04%, P=0.011) and greater reduction of recession width three months after surgery (P=0.007) but the reduction in VRD at this side was not significantly greater. Conclusions: Gingival unit graft might be an acceptable modality in Miller Class I/II recession defects. This technique may have advantages over free gingival graft such as significantly superior clinical and esthetic results. PMID:28392815
Lung volume is a determinant of aerosol bolus dispersion.
Schulz, Holger; Eder, Gunter; Heyder, Joachim
2003-01-01
The technique of inhaling a small volume element labeled with particles ("aerosol bolus") can be used to assess convective gas mixing in the lung. While a bolus undergoes mixing in the lung, particles are dispersed in an increasing volume of the respired air. However, determining factors of bolus dispersion are not yet completely understood. The present study tested the hypothesis that bolus dispersion is related, among others, to the total volume in which the bolus is allowed to mix--i.e., to the individual lung size. Bolus dispersion was measured in 32 anesthetized, mechanically ventilated dogs with total lung capacities (TLCs) of 1.1-2.5 L. Six-milliliter aerosol boluses were introduced at various preselected time-points during inspiration to probe different volumetric lung depths. Dispersion (SD) was determined by moment analysis of particle concentrations in the expired air. We found linear correlations between SD at a given lung depth and the individual end-inspiratory lung volume (V(L)). The relationship was tightest for boluses inhaled deepest into the lungs: SD(40) = 0.068 V(L) - 1.77, r(2) = 0.59. Normalizing SD to V(L) abolished this dependency and resulted in a considerable reduction of inter-individual variability as compared to the uncorrected measurements. These data indicate that lung size influences measurements of bolus dispersion. It therefore appears reasonable to apply a normalization procedure before interpreting the data. Apart from a reduction in measurement variability, this should help to separate the effects on bolus dispersion of altered lung volumes and altered mixing processes in diseased lungs.
Ex vivo imaging of early dental caries within the interproximal space
NASA Astrophysics Data System (ADS)
Choo-Smith, Lin-P'ing; Hewko, Mark D.; Dufour, Marc L.; Fulton, Crystal; Qiu, Pingli; Gauthier, Bruno; Padioleau, Christian; Bisaillon, Charles-Etienne; Dong, Cecilia; Cleghorn, Blaine M.; Lamouche, Guy; Sowa, Michael G.
2009-02-01
Optical coherence tomography (OCT) is emerging as a technology that can potentially be used for the detection and monitoring of early dental enamel caries since it can provide high-resolution depth imaging of early lesions. To date, most caries detection optical technologies are well suited for examining caries at facial, lingual, incisal and occlusal surfaces. The approximal surfaces between adjacent teeth are difficult to examine due to lack of visual access and limited space for these new caries detection tools. Using a catheter-style probe developed at the NRC-Industrial Materials Institute, the probe was inserted into the interproximal space to examine the approximal surfaces with OCT imaging at 1310 nm. The probe was rotated continuously and translated axially to generate depth images in a spiral fashion. The probe was used in a mock tooth arch model consisting of extracted human teeth mounted with dental rope wax in their anatomically correct positions. With this ex vivo model, the probe provided images of the approximal surfaces revealing morphological structural details, regions of calculus, and especially regions of early dental caries (white spot lesions). Results were compared with those obtained from OCT imaging of individual samples where the approximal surfaces of extracted teeth are accessible on a lab-bench. Issues regarding access, regions of interest, and factors to be considered in an in vivo setting will be discussed. Future studies are aimed at using the probe in vivo with patient volunteers.
Tal, Haim; Moses, Ofer; Zohar, Ron; Meir, Haya; Nemcovsky, Carlos
2002-12-01
Acellular dermal matrix allograft (ADMA) has successfully been applied as a substitute for free connective tissue grafts (CTG) in various periodontal procedures, including root coverage. The purpose of this study was to clinically compare the efficiency of ADMA and CTG in the treatment of gingival recessions > or = 4 mm. Seven patients with bilateral recession lesions participated. Fourteen teeth presenting gingival recessions > or = 4 mm were randomly treated with ADMA or CTG covered by coronally advanced flaps. Recession, probing depth, and width of keratinized tissue were measured preoperatively and 12 months postoperatively. Changes in these clinical parameters were calculated within and compared between groups and analyzed statistically. Baseline recession, probing depth, and keratinized tissue width were similar for both groups. At 12 months, root coverage gain was 4.57 mm (89.1%) versus 4.29 mm (88.7%) (P = NS), and keratinized tissue gain was 0.86 mm (36%) versus 2.14 mm (107%) (P < 0.05) for ADMA and CTG, respectively. Probing depth remained unchanged (0.22 mm/0 mm), with no difference between the groups. Recession defects may be covered using ADMA or CTG, with no practical difference. However, CTG results in significantly greater gain of keratinized gingiva.
Periodontitis is related to lung volumes and airflow limitation: a cross-sectional study.
Holtfreter, Birte; Richter, Stefanie; Kocher, Thomas; Dörr, Marcus; Völzke, Henry; Ittermann, Till; Obst, Anne; Schäper, Christoph; John, Ulrich; Meisel, Peter; Grotevendt, Anne; Felix, Stephan B; Ewert, Ralf; Gläser, Sven
2013-12-01
This study aimed to assess the potential association of periodontal diseases with lung volumes and airflow limitation in a general adult population. Based on a representative population sample of the Study of Health in Pomerania (SHIP), 1463 subjects aged 25-86 years were included. Periodontal status was assessed by clinical attachment loss (CAL), probing depth and number of missing teeth. Lung function was measured using spirometry, body plethysmography and diffusing capacity of the lung for carbon monoxide. Linear regression models using fractional polynomials were used to assess associations between periodontal disease and lung function. Fibrinogen and high-sensitivity C-reactive protein (hs-CRP) were evaluated as potential intermediate factors. After full adjustment for potential confounders mean CAL was significantly associated with variables of mobile dynamic and static lung volumes, airflow limitation and hyperinflation (p<0.05). Including fibrinogen and hs-CRP did not change coefficients of mean CAL; associations remained statistically significant. Mean CAL was not associated with total lung capacity and diffusing capacity of the lung for carbon monoxide. Associations were confirmed for mean probing depth, extent measures of CAL/probing depth and number of missing teeth. Periodontal disease was significantly associated with reduced lung volumes and airflow limitation in this general adult population sample. Systemic inflammation did not provide a mechanism linking both diseases.
Interrelationship of Smoking, Lip and Gingival Melanin Pigmentation, and Periodontal Status
Multani, Suraj
2013-01-01
Background Cigarette smoking is a significant risk factor for periodontal disease. It also causes pigmentation of oral mucosa. The present study was aimed to assess the effects of smoking on lip and gingival pigmentation and periodontal status and the relationship between pigmentation and periodontal parameters. Methods A total of 109 smokers and an equal number of non-smoker controls (mean age: 35.9 years, range: 35-44 years) comprised the study sample. All the participants were assessed for pigmentation on lip and gingiva and overall periodontal status (gingival bleeding, probing depth, and loss of attachment at six points in each tooth). Findings All the smokers in this study had lip and gingival pigmentation. Two-third of non-smokers had no pigmentation. The mean scores of lip and gingival pigmentation in smokers were seven and four times higher than those of non-smokers, respectively. Pigmentation and periodontal parameters (except gingival bleeding) were found to be positively related with exposure to smoking exposure. Probing depth and loss of attachment were the highest in subjects with pigmented lips and grade three pigmented gingiva. Conclusion Smoking influenced lip and gingival pigmentation and periodontium. All individuals with lip pigmentation presented some form of gingival pigmentation. Probing depth and loss of attachment were more severe in subjects with lip and gingival pigmentation. PMID:24494159
Depth enhancement of S3D content and the psychological effects
NASA Astrophysics Data System (ADS)
Hirahara, Masahiro; Shiraishi, Saki; Kawai, Takashi
2012-03-01
Stereoscopic 3D (S3D) imaging technologies are widely used recently to create content for movies, TV programs, games, etc. Although S3D content differs from 2D content by the use of binocular parallax to induce depth sensation, the relationship between depth control and the user experience remains unclear. In this study, the user experience was subjectively and objectively evaluated in order to determine the effectiveness of depth control, such as an expansion or reduction or a forward or backward shift in the range of maximum parallactic angles in the cross and uncross directions (depth bracket). Four types of S3D content were used in the subjective and objective evaluations. The depth brackets of comparison stimuli were modified in order to enhance the depth sensation corresponding to the content. Interpretation Based Quality (IBQ) methodology was used for the subjective evaluation and the heart rate was measured to evaluate the physiological effect. The results of the evaluations suggest the following two points. (1) Expansion/reduction of the depth bracket affects preference and enhances positive emotions to the S3D content. (2) Expansion/reduction of the depth bracket produces above-mentioned effects more notable than shifting the cross/uncross directions.
Automated system for periodontal disease diagnosis
NASA Astrophysics Data System (ADS)
Albalat, Salvador E.; Alcaniz-Raya, Mariano L.; Juan, M. Carmen; Grau Colomer, Vincente; Monserrat, Carlos
1997-04-01
Evolution of periodontal disease is one of the most important data for the clinicians in order to achieve correct planning and treatment. Clinical measure of the periodontal sulcus depth is the most important datum to know the exact state of periodontal disease. These measures must be done periodically study bone resorption evolution around teeth. Time factor of resorption indicates aggressiveness of periodontitis. Manual probes are commonly used with direct reading. Mechanical probes give automatic signal but this method uses complicated and heavy probes that are only limited for University researchers. Probe position must be the same to have right diagnosis. Digital image analysis of periodontal probing provides practical, accurate and easy tool. Gum and plaque index could also be digitally measured with this method.
Disinfection of a probe used in ultrasound-guided prostate biopsy.
Rutala, William A; Gergen, Maria F; Weber, David J
2007-08-01
Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.
Floating Probe Assembly for Measuring Temperature of Water
NASA Technical Reports Server (NTRS)
Stewart, Randy; Ruffin, Clyde
2002-01-01
A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (=71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in.(=1.9 cm) thick and 2.5 in. (=6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger.
Floating Probe Assembly for Measuring Temperature of Water
NASA Technical Reports Server (NTRS)
Selinsky, T.; Stewart, Randy; Ruffin, Clyde
2002-01-01
A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (approx. = 71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in. (approx. = 1.9 cm) thick and 2.5 in. (approx. = 6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger. This work was done by Randy
NASA Astrophysics Data System (ADS)
Nagihara, Seiichi; Hedlund, Magnus; Zacny, Kris; Taylor, Patrick T.
2014-03-01
The needle probe method (also known as the ‘hot wire’ or ‘line heat source’ method) is widely used for in-situ thermal conductivity measurements on terrestrial soils and marine sediments. Variants of this method have also been used (or planned) for measuring regolith on the surfaces of extra-terrestrial bodies (e.g., the Moon, Mars, and comets). In the near-vacuum condition on the lunar and planetary surfaces, the measurement method used on the earth cannot be simply duplicated, because thermal conductivity of the regolith can be ~2 orders of magnitude lower. In addition, the planetary probes have much greater diameters, due to engineering requirements associated with the robotic deployment on extra-terrestrial bodies. All of these factors contribute to the planetary probes requiring a much longer time of measurement, several tens of (if not over a hundred) hours, while a conventional terrestrial needle probe needs only 1 to 2 min. The long measurement time complicates the surface operation logistics of the lander. It also negatively affects accuracy of the thermal conductivity measurement, because the cumulative heat loss along the probe is no longer negligible. The present study improves the data reduction algorithm of the needle probe method by shortening the measurement time on planetary surfaces by an order of magnitude. The main difference between the new scheme and the conventional one is that the former uses the exact mathematical solution to the thermal model on which the needle probe measurement theory is based, while the latter uses an approximate solution that is valid only for large times. The present study demonstrates the benefit of the new data reduction technique by applying it to data from a series of needle probe experiments carried out in a vacuum chamber on a lunar regolith simulant, JSC-1A. The use of the exact solution has some disadvantage, however, in requiring three additional parameters, but two of them (the diameter and the volumetric heat capacity of the probe) can be measured and the other (the volumetric heat capacity of the regolith/stimulant) may be estimated from the surface geologic observation and temperature measurements. Therefore, overall, the new data reduction scheme would make in-situ thermal conductivity measurement more practical on planetary missions.
NASA Technical Reports Server (NTRS)
Nagihara, S.; Hedlund, M.; Zacny, K.; Taylor, P. T.
2013-01-01
The needle probe method (also known as the' hot wire' or 'line heat source' method) is widely used for in-situ thermal conductivity measurements on soils and marine sediments on the earth. Variants of this method have also been used (or planned) for measuring regolith on the surfaces of extra-terrestrial bodies (e.g., the Moon, Mars, and comets). In the near-vacuum condition on the lunar and planetary surfaces, the measurement method used on the earth cannot be simply duplicated, because thermal conductivity of the regolith can be approximately 2 orders of magnitude lower. In addition, the planetary probes have much greater diameters, due to engineering requirements associated with the robotic deployment on extra-terrestrial bodies. All of these factors contribute to the planetary probes requiring much longer time of measurement, several tens of (if not over a hundred) hours, while a conventional terrestrial needle probe needs only 1 to 2 minutes. The long measurement time complicates the surface operation logistics of the lander. It also negatively affects accuracy of the thermal conductivity measurement, because the cumulative heat loss along the probe is no longer negligible. The present study improves the data reduction algorithm of the needle probe method by shortening the measurement time on planetary surfaces by an order of magnitude. The main difference between the new scheme and the conventional one is that the former uses the exact mathematical solution to the thermal model on which the needle probe measurement theory is based, while the latter uses an approximate solution that is valid only for large times. The present study demonstrates the benefit of the new data reduction technique by applying it to data from a series of needle probe experiments carried out in a vacuum chamber on JSC-1A lunar regolith stimulant. The use of the exact solution has some disadvantage, however, in requiring three additional parameters, but two of them (the diameter and the volumetric heat capacity of the probe) can be measured and the other (the volumetric heat capacity of the regolith/stimulant) may be estimated from the surface geologic observation and temperature measurements. Therefore, overall, the new data reduction scheme would make in-situ thermal conductivity measurement more practical on planetary missions.
Periodontal status in crack and cocaine addicted men: a cross-sectional study.
Cury, Patricia Ramos; Oliveira, Maria Graças Alonso; Dos Santos, Jean Nunes
2017-02-01
This cross-sectional study evaluated the association between crack/cocaine addiction and periodontal disease in men. Periodontal examination (probing depth, clinical attachment level, bleeding on probing, and plaque index) and interviews were performed in 160 patients (≥18 years) from the Federal University of Bahia. Crack and cocaine dependence was defined according to the medical records and interviews of each patient; all drug addicted volunteers used both crack and cocaine. T test, Chi-square test, and logistic regression were used to assess the associations between destructive periodontal disease and crack/cocaine dependence (p ≤ 0.05). Probing depth was significantly greater in crack/cocaine addicted individuals (2.84 ± 0.76 mm) compared with non-addicted individuals (2.55 ± 0.73 mm, p = 0.04). After adjusting for covariates, periodontitis was not significantly associated with crack/cocaine addiction (OR = 2.31, 95 % CI = 0.82-6.46, p = 0.11), which was only associated with age ≥35 years (OR = 4.16, 95 % CI = 1.65-10.50, p = 0.003) and higher dental plaque index (OR = 6.46, 95 % CI = 1.95-21.42, p = 0.002). In conclusion, although probing depth was greater in crack/cocaine addicted individuals, destructive periodontal disease was not associated with crack and cocaine addiction in the present population. Destructive periodontal disease was associated with age and dental plaque. Further studies in a larger sample size are required to confirm the results.
Restoration of the Apollo 15 Heat Flow Experiment Data from 1975 to 1977
NASA Technical Reports Server (NTRS)
Nagihara, S.; Nakamura, Y.; Taylor, P. T.; Williams, D. R.; Kiefer, W. S.
2017-01-01
The Apollo 15 Heat Flow Experiment (HFE) was conducted from July 1971 through January 1977. Two heat flow probes were deployed roughly 8.5 meters apart. Probe 1 and Probe 2 penetrated to 1.4-meters and 1-meter depths into the lunar regolith, respectively. Temperatures at different depths and the surface were logged with 7.25-minute intervals and transmitted to Earth. At the conclusion of the experiment, only data obtained from July 1971 through December 1974 were processed and archived at the National Space Science Data Center (NSSDC) by the principal investigator of the experiment, Marcus Langseth of Columbia University. Langseth died in 1997. It is not known what happened to the HFE data tapes he used. Current researchers have strong interests in re-examining the HFE data for the full duration of the experiment. We have recovered and processed large portions of the Apollo 15 HFE data from 1975 through 1977 by assembling data and metadata from various sources.
Bogren, Anna; Teles, Ricardo P; Torresyap, Gay; Haffajee, Anne D; Socransky, Sigmund S; Jönsson, Kerstin; Wennström, Jan L
2008-02-01
To test the hypothesis of a superior clinical and microbiological effect of the combined use of powered toothbrush+triclosan-containing dentifrice compared with manual toothbrush+regular fluoride-containing dentifrice in periodontal maintenance patients. A total of 128 periodontitis subjects involved in recall programmes were randomized to use either powered toothbrush with triclosan-dentifrice (test) or manual toothbrush and standard dentifrice (control). Supportive periodontal treatment was provided at baseline and every 6 months. Plaque, bleeding on probing (BoP), probing pocket depth (PPD) and relative attachment level (RAL) were scored at baseline, 1, 2 and 3 years. Subgingival plaque samples were taken and analysed for their content of 40 bacterial species at each examination interval. All analyses were performed by "intention-to-treat" protocol. Both groups showed significant reduction in BoP, PPD and in mean total counts of the 40 bacterial species between baseline and 3 years, while plaque score and RAL remained almost unchanged. No significant differences between the two prevention programmes were found for any of the clinical outcome variables or in mean counts of the various bacterial species. The study failed to demonstrate superior clinical and microbiological effects of powered toothbrush+triclosan dentifrice compared with manual toothbrush+standard fluoride-dentifrice in periodontitis-susceptible patients on regular maintenance therapy.
3D Ultrasonic Non-destructive Evaluation of Spot Welds Using an Enhanced Total Focusing Method
NASA Astrophysics Data System (ADS)
Jasiuniene, Elena; Samaitis, Vykintas; Mazeika, Liudas; Sanderson, Ruth
2015-02-01
Spot welds are used to join sheets of metals in the automotive industry. When spot weld quality is evaluated using conventional ultrasonic manual pulse-echo method, the reliability of the inspection is affected by selection of the probe diameter and the positioning of the probe in the weld center. The application of a 2D matrix array is a potential solution to the aforementioned problems. The objective of this work was to develop a signal processing algorithm to reconstruct the 3D spot weld volume showing the size of the nugget and the defects in it. In order to achieve this, the conventional total focusing method was enhanced by taking into account the directivities of the single elements of the array and the divergence of the ultrasonic beam due to the propagation distance. Enhancements enabled a reduction in the background noise and uniform sensitivity at different depths to be obtained. The proposed algorithm was verified using a finite element model of ultrasonic wave propagation simulating three common spot weld conditions: a good weld, an undersized weld, and a weld containing a pore. The investigations have demonstrated that proposed method enables the determination of the size of the nugget and detection of discontinuities.
Sezgin, Yasemin; Uraz, Ahu; Taner, I Levent; Çulhaoğlu, Rana
2017-01-26
Anorganic bovine bone mineral (ABBM) is extensively used in the treatment of intra-bony defects. Platelet-rich fibrin (PRF) is a new-generation platelet concentrate with a simplified technique. Although certain studies have reported the use of PRF in the treatment of intra-bony defects, to date, none of them have evaluated its additive effects with ABBM. Therefore, a randomised, split-mouth clinical trial was conducted to compare healing of intra-bony defects treated with an ABBM-PRF combination with healing of those treated with ABBM alone. By using a split-mouth design, 15 paired intra-bony defects were randomly treated with either ABBM alone (control group) or ABBM-PRF combination (test group). Following clinical parameters and radiographical measurements were recorded at baseline and 6 months after treatment: plaque index (PI), gingival index (GI), probing depth (PD), gingival recession (GR), clinical attachment level (CAL), vertical bone loss, depth of defect and defect angle. Preoperative clinical and radiographical measurements were similar for the test and control groups. Statistically significant reductions in GI, PD, CAL, vertical bone loss, depth of intra-bony defect and widening of defect angle were detected after treatment in both groups. With respect to inter-group analysis, gain in CAL was significantly greater in the test group than in the control group, whereas no inter-group differences were observed in any other parameter. The results of this study indicate that both therapies are effective in the treatment of intra-bony defects.
Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials
NASA Astrophysics Data System (ADS)
Hofmann, F.; Mason, D. R.; Eliason, J. K.; Maznev, A. A.; Nelson, K. A.; Dudarev, S. L.
2015-11-01
Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying with transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants.
Dynamics of the bleaching of tail states in CdS1- x Se x mixed crystals
NASA Astrophysics Data System (ADS)
Breitkopf, T.; Kalt, H.; Klingshirn, C.; Reznitsky, A.
1996-06-01
The kinetics of excitons localized by statistic potential fluctuations have been studied in CdS 1-xSex ternary alloys under quasi-stationary excitation conditions and have been time resolved after picosecond-pulse excitation. In luminescence experiments we observe the filling of the band tail with rising excitation intensity. The reduction of carrier density with time by recombination leads to a red shift of the luminescence band after picosecond-pulse excitation. Bleaching of absorption of the localized states is found in pump-probe experiments. Its dynamics depend on the localization depth of the excitons and on the pump-pulse energy. Using higher excitation intensities, we observe stimulated emission in luminescence, correlated with significant changes in the behavior of the absorption bleaching. The possible origin of the stimulated emission situated in the spectral region of localized states is discussed.
Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials
Hofmann, F.; Mason, D. R.; Eliason, J. K.; ...
2015-11-03
Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying withmore » transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants.« less
Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hofmann, F.; Mason, D. R.; Eliason, J. K.
Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying withmore » transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants.« less
Nagaveni, N B; Kumari, K Nandini; Poornima, P; Reddy, V V Subba
2015-01-01
Treatment of an endo-perio lesion involving a non-vital young permanent tooth is a highly challenging task to Pediatric Dentists. There is a quest for the newer biological approach to management of these lesions as traditional methods have various disadvantages. Recently, platelet-rich fibrin (PRF), a second-generation platelet concentrate, is rich in growth factors have been used in the periodontal regeneration procedure. The purpose of this paper is to describe the efficacy of PRF in the treatment of a deep intra bony defect associated with an endo-perio lesion in an immature right mandibular first premolar of 12-year-old female patient. A freshly prepared autologous PRF membrane was placed in the bony defect following debridement. Clinical and radiographic follow-up were performed at regular intervals that revealed absence of pain, gain in clinical attachment level, reduction in probing depth, and excellent bone regeneration indicating successful outcome.
A sequential approach in treatment of perio-endo lesion
Narang, Sumit; Narang, Anu; Gupta, Ruby
2011-01-01
The success of a combined periodontal and endodontic lesion depends on the elimination of both of these disease processes. In the case of a combined endo-perio lesion, the endodontic therapy results in healing of the endodontic component of involvement while the prognosis of tooth would finally depend on the healing of the periodontal structures. This case report evaluates the efficacy of bioactive glass in the management of furcation defect associated with an endo-perio lesion in a right mandibular first molar. A 22-year-old male patient with an endo-perio lesion in the right mandibular first molar was initially treated with endodontic therapy. Following the endodontic treatment, the furcation defect was treated using bioactive glass in a putty form. At the end of 9 months, there was a gain in the clinical attachment level and reduction in probing depth. Radiographic evidence showed that there was a significant bony fill. PMID:21976845
A sequential approach in treatment of perio-endo lesion.
Narang, Sumit; Narang, Anu; Gupta, Ruby
2011-04-01
The success of a combined periodontal and endodontic lesion depends on the elimination of both of these disease processes. In the case of a combined endo-perio lesion, the endodontic therapy results in healing of the endodontic component of involvement while the prognosis of tooth would finally depend on the healing of the periodontal structures. This case report evaluates the efficacy of bioactive glass in the management of furcation defect associated with an endo-perio lesion in a right mandibular first molar. A 22-year-old male patient with an endo-perio lesion in the right mandibular first molar was initially treated with endodontic therapy. Following the endodontic treatment, the furcation defect was treated using bioactive glass in a putty form. At the end of 9 months, there was a gain in the clinical attachment level and reduction in probing depth. Radiographic evidence showed that there was a significant bony fill.
Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials
Hofmann, F.; Mason, D. R.; Eliason, J. K.; Maznev, A. A.; Nelson, K. A.; Dudarev, S. L.
2015-01-01
Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying with transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants. PMID:26527099
Telenkov, Sergey A; Dave, Digant P; Sethuraman, Shriram; Akkin, Taner; Milner, Thomas E
2004-01-07
We describe a differential phase low-coherence interferometric probe for non-invasive, quantitative imaging of photothermal phenomena in biological materials. Our detection method utilizes principles of optical coherence tomography with differential phase measurement of interference fringe signals. A dual-channel optical low-coherence probe is used to analyse laser-induced thermoelastic and thermorefractive effects in tissue with micrometre axial resolution and nanometre sensitivity. We demonstrate an application of the technique using tissue phantoms and ex-vivo tissue specimens of rodent dorsal skin.
Laser remote sensing of an algal bloom in a freshwater reservoir
NASA Astrophysics Data System (ADS)
Grishin, M. Ya; Lednev, V. N.; Pershin, S. M.; Bunkin, A. F.; Kobylyanskiy, V. V.; Ermakov, S. A.; Kapustin, I. A.; Molkov, A. A.
2016-12-01
Laser remote sensing of an algal bloom in a freshwater reservoir on the Volga River in central Russia was carried out. The compact Raman lidar was installed on a small ship to probe the properties of the surface water layer in different typical regions of Gorky Water Reservoir. Elastic and Raman scattering as well as chlorophyll fluorescence were quantified, mapped and compared with data acquired by a commercial salinity, temperature and depth probe (STD probe) equipped with a blue-green algae sensor. Good correlation between lidar and STD measurements was established.
High resolution axicon-based endoscopic FD OCT imaging with a large depth range
NASA Astrophysics Data System (ADS)
Lee, Kye-Sung; Hurley, William; Deegan, John; Dean, Scott; Rolland, Jannick P.
2010-02-01
Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF). This optics could accommodate for varying sizes of tubular structures across patients and along the tree within a single patient. In the paper, we demonstrate an extended DOF without sacrificing resolution showing rotational images in biological tubular samples with 2.5 μm axial resolution, 10 ìm lateral resolution, and > 4 mm depth range using a custom designed probe.
Assessing Temporal Stability for Coarse Scale Satellite Moisture Validation in the Maqu Area, Tibet
Bhatti, Haris Akram; Rientjes, Tom; Verhoef, Wouter; Yaseen, Muhammad
2013-01-01
This study evaluates if the temporal stability concept is applicable to a time series of satellite soil moisture images so to extend the common procedure of satellite image validation. The area of study is the Maqu area, which is located in the northeastern part of the Tibetan plateau. The network serves validation purposes of coarse scale (25–50 km) satellite soil moisture products and comprises 20 stations with probes installed at depths of 5, 10, 20, 40, 80 cm. The study period is 2009. The temporal stability concept is applied to all five depths of the soil moisture measuring network and to a time series of satellite-based moisture products from the Advance Microwave Scanning Radiometer (AMSR-E). The in-situ network is also assessed by Pearsons's correlation analysis. Assessments by the temporal stability concept proved to be useful and results suggest that probe measurements at 10 cm depth best match to the satellite observations. The Mean Relative Difference plot for satellite pixels shows that a RMSM pixel can be identified but in our case this pixel does not overlay any in-situ station. Also, the RMSM pixel does not overlay any of the Representative Mean Soil Moisture (RMSM) stations of the five probe depths. Pearson's correlation analysis on in-situ measurements suggests that moisture patterns over time are more persistent than over space. Since this study presents first results on the application of the temporal stability concept to a series of satellite images, we recommend further tests to become more conclusive on effectiveness to broaden the procedure of satellite validation. PMID:23959237
Photoacoustic imaging probe for detecting lymph nodes and spreading of cancer at various depths
NASA Astrophysics Data System (ADS)
Lee, Yong-Jae; Jeong, Eun-Ju; Song, Hyun-Woo; Ahn, Chang-Geun; Noh, Hyung Wook; Sim, Joo Yong; Song, Dong Hoon; Jeon, Min Yong; Lee, Susung; Kim, Heewon; Zhang, Meihua; Kim, Bong Kyu
2017-09-01
We propose a compact and easy to use photoacoustic imaging (PAI) probe structure using a single strand of optical fiber and a beam combiner doubly reflecting acoustic waves for convenient detection of lymph nodes and cancers. Conventional PAI probes have difficulty detecting lymph nodes just beneath the skin or simultaneously investigating lymph nodes located in shallow as well as deep regions from skin without any supplementary material because the light and acoustic beams are intersecting obliquely in the probe. To overcome the limitations and improve their convenience, we propose a probe structure in which the illuminated light beam axis coincides with the axis of the ultrasound. The developed PAI probe was able to simultaneously achieve a wide range of images positioned from shallow to deep regions without the use of any supplementary material. Moreover, the proposed probe had low transmission losses for the light and acoustic beams. Therefore, the proposed PAI probe will be useful to easily detect lymph nodes and cancers in real clinical fields.
Interaction of depth probes and style of depiction
van Doorn, Andrea J.; Koenderink, Jan J.; Leyssen, Mieke H. R.; Wagemans, Johan
2012-01-01
We study the effect of stylistic differences on the nature of pictorial spaces as they appear to an observer when looking into a picture. Four pictures chosen from diverse styles of depiction were studied by 2 different methods. Each method addresses pictorial depth but draws on a different bouquet of depth cues. We find that the depth structures are very similar for 8 observers, apart from an idiosyncratic depth scaling (up to a factor of 3). The differences between observers generalize over (very different) pictures and (very different) methods. They are apparently characteristic of the person. The differences between depths as sampled by the 2 methods depend upon the style of the picture. This is the case for all observers except one. PMID:23145306
Rooting depth explains [CO2] x drought interaction in Eucalyptus saligna.
Duursma, Remko A; Barton, Craig V M; Eamus, Derek; Medlyn, Belinda E; Ellsworth, David S; Forster, Michael A; Tissue, David T; Linder, Sune; McMurtrie, Ross E
2011-09-01
Elevated atmospheric [CO(2)] (eC(a)) often decreases stomatal conductance, which may delay the start of drought, as well as alleviate the effect of dry soil on plant water use and carbon uptake. We studied the interaction between drought and eC(a) in a whole-tree chamber experiment with Eucalyptus saligna. Trees were grown for 18 months in their C(a) treatments before a 4-month dry-down. Trees grown in eC(a) were smaller than those grown in ambient C(a) (aC(a)) due to an early growth setback that was maintained throughout the duration of the experiment. Pre-dawn leaf water potentials were not different between C(a) treatments, but were lower in the drought treatment than the irrigated control. Counter to expectations, the drought treatment caused a larger reduction in canopy-average transpiration rates for trees in the eC(a) treatment compared with aC(a). Total tree transpiration over the dry-down was positively correlated with the decrease in soil water storage, measured in the top 1.5 m, over the drying cycle; however, we could not close the water budget especially for the larger trees, suggesting soil water uptake below 1.5 m depth. Using neutron probe soil water measurements, we estimated fractional water uptake to a depth of 4.5 m and found that larger trees were able to extract more water from deep soil layers. These results highlight the interaction between rooting depth and response of tree water use to drought. The responses of tree water use to eC(a) involve interactions between tree size, root distribution and soil moisture availability that may override the expected direct effects of eC(a). It is essential that these interactions be considered when interpreting experimental results.
Howshigan, J; Perera, K; Samita, S; Rajapakse, P S
2015-12-01
Plant derived preparations have been essential components for maintenance of oral hygiene and the treatment of oral diseases globally since ancient times. Acacia chundra Willd, Adhatoda vasica Nees., Mimusops elengi L., Piper nigrum L., Pongamia pinnate L. Pirerre, Quercus infectoria Olivier., Syzygium aromaticum L., Terminalia chebula Retz., Zingiber offici-nale Roscoe., individually or in combination, have been used for this purpose because of their beneficial effects. To study the efficacy of an Ayurvedic toothpaste containing these herbs in patients with chronic gingivitis. Otherwise healthy males and non-pregnant females (n=80) aged 18-35 years with ≥20 teeth were randomly assigned to Group 1 (herbal toothpaste) and Group 2 (placebo toothpaste). Quigley Hein plaque index (PS), bleeding on probing (BOP) and probing pocket depth (PPD), were recorded for all teeth at six sites, and one ml of resting saliva was collected to ascertain anaerobic and aerobic bacterial counts at baseline, and at 4, 8, 12 and 24 weeks. Full-mouth prophylaxis was performed and instructions for brushing with the allocated toothpaste for 6 months were given at baseline. Sixty-six participants, 34 in Group 1 and 32 in Group 2 completed the study. Clinical examinations were performed by the same examiner blinded to group allocation. Linear mixed model analysis revealed significant reductions of PS, BOP, PPD (p<0.0001) and total salivary anaerobic counts (p<0.05) in Group 1 at all prescribed visits compared to Group 2. Moreover the reduction increased overtime. No unpleasant effects of toothpaste use were reported. This study provides robust evidence of the beneficial antiplaque and antigingivitis effects of the test herbal toothpaste Sudantha® on patients with chronic gingivitis.
NASA Technical Reports Server (NTRS)
Ruff-Roberts, A. L.; Kuenen, J. G.; Ward, D. M.
1994-01-01
Oligodeoxynucleotide hybridization probes were developed to complement specific regions of the small subunit (SSU) rRNA sequences of cultivated and uncultivated cyanobacteria and Chloroflexus-like bacteria, which inhabit hot spring microbial mats. The probes were used to investigate the natural distribution of SSU rRNAs from these species in mats of Yellowstone hot springs of different temperatures and pHs as well as changes in SSU rRNA distribution resulting from 1-week in situ shifts in temperature, pH, and light intensity. Synechococcus lividus Y-7c-s SSU rRNA was detected only in the mat of a slightly acid spring, from which it may have been initially isolated, or when samples from a more alkaline spring were incubated in the more acid spring. Chloroflexus aurantiacus Y-400-fl SSU rRNA was detected only in a high-temperature mat sample from the alkaline Octopus Spring or when lower-temperature samples from this mat were incubated at the high-temperature site. SSU rRNAs of uncultivated species were more widely distributed. Temperature distributions and responses to in situ temperature shifts suggested that some of the uncultivated cyanobacteria might be adapted to high-, moderate-, and low-temperature ranges whereas an uncultivated Chloroflexus-like bacterium appears to have broad temperature tolerance. SSU rRNAs of all uncultivated species inhabiting a 48 to 51 degrees C Octopus Spring mat site were most abundant in the upper 1 mm and were not detected below a 2.5-to 3.5-mm depth, a finding consistent with their possible phototrophic nature. However, the effects of light intensity reduction on these SSU rRNAs were variable, indicating the difficulty of demonstrating a phototrophic phenotype in light reduction experiments.
Meulman, Tatiana; Casarin, Renato C. V.; Peruzzo, Daiane C.; Giorgetti, Ana Paula; Barbagallo, André; Casati, Márcio Z.; Sallum, Enilson A.; Gonçalves, Reginaldo B.; Nociti Jr, Francisco H.
2012-01-01
Background The aim of this study was to assess subgingival microbiological changes in smokers versus non-smokers presenting severe chronic periodontitis after supragingival periodontal therapy (ST). Methods Non-smokers (n=10) and smokers (n=10) presenting at least nine teeth with probing pocket depth (PPD) (≥5 mm), bleeding on probing (BoP), and no history of periodontal treatment in the last 6 months were selected. Clinical parameters assessed were plaque index (PI), BoP, PPD, relative gingival margin position (rGMP) and relative clinical attachment level (rCAL). Subgingival biofilm was collected before and 21 days after ST. DNA was extracted and the 16S rRNA gene was amplified with the universal primer pair, 27F and 1492R. Amplified genes were cloned, sequenced, and identified by comparison with known 16S rRNA sequences. Statistical analysis was performed by Student's t and Chi-Square tests (α=5%). Results Clinically, ST promoted a significant reduction in PI and PPD, and gain of rCAL for both groups, with no significant intergroup difference. Microbiologically, at baseline, data analysis demonstrated that smokers harbored a higher proportion of Porphyromonas endodontalis, Bacteroidetes sp., Fusobacterium sp. and Tannerella forsythia and a lower number of cultivated phylotypes (p<0.05). Furthermore, non-smokers featured significant reductions in key phylotypes associated with periodontitis, whereas smokers presented more modest changes. Conclusion Within the limits of the present study, ST promoted comparable clinical improvements in smokers and non-smokers with severe chronic periodontitis. However, in smokers, ST only slightly affected the subgingival biofilm biodiversity, as compared with non-smokers. PMID:22232720
Jagadish Pai, B. S.; Rajan, Smitha Anitha; Srinivas, M.; Padma, R.; Suragimath, Girish; Walvekar, Amit; Goel, Saakshi; Kamath, Vinesh
2013-01-01
Background: The purpose of this study was to clinically evaluate the benefits of sub gingival chlorhexidine (CHX) varnish and biodegradable CHX chip application used as an adjunct to scaling and root planning (SRP) as combined therapy and also to compare the effect of combined therapy with SRP alone. Materials and Methods: Fifteen patients with at least three sites with a probing pocket depth (PPD) of 5-8 mm were considered. Following baseline evaluation, all three sites were subjected for SRP. After completing SRP, each site was randomly subjected for CHX varnish, CHX chip application and the 3rd site was left without any medication as a control. Clinical parameters such as sulcus bleeding index, plaque index, bleeding on probing (BOP), PPD, and clinical attachment level (CAL) were recorded at baseline, 1 month and 3 months post-operatively. Results: All three groups presented with an improvement in clinical parameters compared to baseline. The mean reduction in PPD was 2.4 mm in SRP sites, 2.5 mm in SRP + CHX varnish sites and 2.8 mm in SRP + CHX chip sites. The mean gain in CAL was 2.4 mm in SRP sites, 2.3 mm in SRP + CHX varnish sites and 2.8 mm SRP + CHX chip sites. Interpretation and Conclusion: The present study indicated that application of CHX varnish and placement of CHX chip as an adjunct to SRP produced a clinically significant reduction in the PPD, BOP and a gain in CAL at 30th day and 90th day from baseline when compared to SRP alone. The results though were not statistically significant. PMID:24015002
Comparison between two surgical techniques for root coverage with an acellular dermal matrix graft.
Andrade, Patrícia F; Felipe, Maria Emília M C; Novaes, Arthur B; Souza, Sérgio L S; Taba, Mário; Palioto, Daniela B; Grisi, Márcio F M
2008-03-01
The aim of this randomized, controlled, clinical study was to compare two surgical techniques with the acellular dermal matrix graft (ADMG) to evaluate which technique could provide better root coverage. Fifteen patients with bilateral Miller Class I gingival recession areas were selected. In each patient, one recession area was randomly assigned to the control group, while the contra-lateral recession area was assigned to the test group. The ADMG was used in both groups. The control group was treated with a broader flap and vertical-releasing incisions, and the test group was treated with the proposed surgical technique, without releasing incisions. The clinical parameters evaluated before the surgeries and after 12 months were: gingival recession height, probing depth, relative clinical attachment level and the width and thickness of keratinized tissue. There were no statistically significant differences between the groups for all parameters at baseline. After 12 months, there was a statistically significant reduction in recession height in both groups, and there was no statistically significant difference between the techniques with regard to root coverage. Both surgical techniques provided significant reduction in gingival recession height after 12 months, and similar results in relation to root coverage.
Minocycline HCl microspheres reduce red-complex bacteria in periodontal disease therapy.
Goodson, J Max; Gunsolley, John C; Grossi, Sara G; Bland, Paul S; Otomo-Corgel, Joan; Doherty, Frances; Comiskey, Judy
2007-08-01
The objective of this trial was to measure the antimicrobial effects of a minocycline HCl microsphere (MM) local drug-delivery system when used as an adjunct to scaling and root planing (SRP). DNA probe analysis for 40 bacteria was used to evaluate the oral bacteria of 127 subjects with moderate to advanced chronic periodontitis. Subjects were randomly assigned to either SRP alone (N = 65) or MM + SRP (N = 62). The primary endpoints of this study were changes in numbers and proportions of the red-complex bacteria (RCB) and the sum of Porphyromonas gingivalis, Tannerella forsythia (formally T. forsythensis), and Treponema denticola relative to 40 oral bacteria at each test site from baseline to day 30. Numbers of RCB from the five test sites were averaged to provide a value for each subject. MM + SRP reduced the proportion of RCB by 6.49% and the numbers by 9.4 x 10(5). The reduction in RCB proportions and numbers by SRP alone (5.03% and 5.1 x 10(5), respectively) was significantly less. In addition, MM + SRP reduced probing depth by 1.38 mm (compared to 1.01 mm by SRP alone), bleeding on probing was reduced by 25.2% (compared to 13.8% by SRP alone), and a clinical attachment level gain of 1.16 mm (compared to 0.80 mm by SRP alone) was achieved. These observations support the hypothesis that RCBs are responsible for periodontal disease and that local antimicrobial therapy using MM + SRP effectively reduces numbers of RCBs and their proportions to a greater extent than SRP alone.
Test probe for surface mounted leadless chip carrier
Meyer, Kerry L.; Topolewski, John
1989-05-23
A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.
Test probe for surface mounted leadless chip carrier
Meyer, K.L.; Topolewski, J.
1987-10-02
A test probe for a surface mounted leadless chip carrier is disclosed. The probe includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe. 1 fig.
CASSINI. Report on the Phase A study: Saturn Orbiter and Titan probe
NASA Technical Reports Server (NTRS)
1988-01-01
An in-depth, second phase exploration of Saturn is proposed. The scientific objectives involving Titan, Saturn's rings, icy satellites, magnetosphere, Jupiter, asteroids, and cruise science are covered. Other topics presented include: (1) the model payloads; (2) project requirements; (3) mission; (4) launch vehicle; (5) the orbiter system; (6) the Titan probe system; (7) mission operations; (8) management; and (9) development plan.
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... a minimum mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact... and it has a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac... impact surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000...
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... a minimum mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact... and it has a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac... impact surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000...
Yoneyama, T; Okamoto, H; Lindhe, J; Socransky, S S; Haffajee, A D
1988-10-01
The present investigation describes probing pocket depth, probing attachment level and recession data from 319 randomly selected subjects, aged 20-79 years, from Ushiku, Japan. The findings are reported as mean values, frequency distributions and percentile plots of the 3 parameters at buccal, interproximal and lingual surfaces of single rooted (incisors, canines, premolars) and molar teeth. Inter-as well as intra-examiner errors for probing pocket depth and probing attachment levels were assessed and found to be small. The data reported revealed that practically all subjects studied had one or more sites in the dentition affected by destructive periodontal disease and that the severity of disease increased with age. It was further observed that in each age group, molars had suffered more attachment loss than single rooted teeth and that the interproximal surfaces as a rule had lost more periodontal tissue support than corresponding buccal and lingual surfaces. The attachment loss difference observed between different surfaces of a given tooth or a group of teeth, however, was comparatively small. In the age groups between 20-59 years, advanced destructive periodontal disease was found in a small subgroup of the subject sample, while after the age of 60 years, widespread destructive periodontitis was common. An attempt was made to examine the progression of destructive disease with age by comparing the frequency distributions of sites with attachment loss of greater than or equal to 3 mm in subjects of different age groups. The data suggested that in younger subject groups, progression was confined to a subset of individuals, while in older age groups, more subjects and sites became involved. A major feature of destructive periodontal disease in older individuals was the accompaniment of attachment loss with recession at the gingival margin. Deep pockets were relatively infrequently detected, while advanced loss of attachment (with recession) occurred at many sites.
Endoscopic optical coherence tomography with a focus-adjustable probe.
Liao, Wenchao; Chen, Tianyuan; Wang, Chengming; Zhang, Wenxin; Peng, Zhangkai; Zhang, Xiao; Ai, Shengnan; Fu, Deyong; Zhou, Tieying; Xue, Ping
2017-10-15
We present a focus-adjustable endoscopic probe for optical coherence tomography (OCT), which is able to acquire images with different focal planes and overcome depth-of-focus limitations by image fusing. The use of a two-way shape-memory-alloy spring enables the probe to adjust working distance over 1.5 mm, providing a large scanning range with high resolution and no sensitivity loss. Equipped with a homemade hollow-core ultrasonic motor, the probe is capable of performing an unobstructed 360 deg field-of-view distal scanning. Both the axial resolution and the best lateral resolution are ∼4 μm, with a sensitivity of 100.3 dB. Spectral-domain OCT imaging of phantom and biological tissues with the probe is also demonstrated.
An atomic-force-microscopy study of the structure of surface layers of intact fibroblasts
NASA Astrophysics Data System (ADS)
Khalisov, M. M.; Ankudinov, A. V.; Penniyaynen, V. A.; Nyapshaev, I. A.; Kipenko, A. V.; Timoshchuk, K. I.; Podzorova, S. A.; Krylov, B. V.
2017-02-01
Intact embryonic fibroblasts on a collagen-treated substrate have been studied by atomic-force microscopy (AFM) using probes of two types: (i) standard probes with tip curvature radii of 2-10 nm and (ii) special probes with a calibrated 325-nm SiO2 ball radius at the tip apex. It is established that, irrespective of probe type, the average maximum fibroblast height is on a level of 1.7 μm and the average stiffness of the probe-cell contact amounts to 16.5 mN/m. The obtained AFM data reveal a peculiarity of the fibroblast structure, whereby its external layers move as a rigid shell relative to the interior and can be pressed inside to a depth dependent on the load only.
Development of a femtosecond micromachining workstation by use of spectral interferometry.
Bera, Sudipta; Sabbah, A J; Durfee, Charles G; Squier, Jeff A
2005-02-15
A workstation that permits real-time measurement of ablation depth while micromachining with femtosecond laser pulses is demonstrated. This method incorporates the unamplified pulse train that is available in a chirped-pulse amplification system as the probe in an arrangement that uses spectral interferometry to measure the ablation depth while cutting with the amplified pulse in thin metal films.
NASA Astrophysics Data System (ADS)
Behm, P.; Hashemi, M.; Hoppe, S.; Wessel, S.; Hagens, R.; Jaspers, S.; Wenck, H.; Rübhausen, M.
2017-11-01
We present confocal spectroscopic imaging measurements applied to in-vivo studies to determine the depth dependent hydration profiles of human skin. The observed spectroscopic signal covers the spectral range from 810 nm to 2100 nm allowing to probe relevant absorption signals that can be associated with e.g. lipid and water-absorption bands. We employ a spectrally sensitive autofocus mechanism that allows an ultrafast focusing of the measurement spot on the skin and subsequently probes the evolution of the absorption bands as a function of depth. We determine the change of the water concentration in m%. The water concentration follows a sigmoidal behavior with an increase of the water content of about 70% within 5 μm in a depth of about 14 μm. We have applied our technique to study the hydration dynamics of skin before and after treatment with different concentrations of glycerol indicating that an increase of the glycerol concentration leads to an enhanced water concentration in the stratum corneum. Moreover, in contrast to traditional corneometry we have found that the application of Aluminium Chlorohydrate has no impact to the hydration of skin.
Periodontal Probe Improves Exams, Alleviates Pain
NASA Technical Reports Server (NTRS)
2008-01-01
Dentists, comedian Bill Cosby memorably mused, tell you not to pick your teeth with any sharp metal object. Then you sit in their chair, and the first thing they grab is an iron hook!" Conventional periodontal probing is indeed invasive, uncomfortable for the patient, and the results can vary greatly between dentists and even for repeated measurements by the same dentist. It is a necessary procedure, though, as periodontal disease is the most common dental disease, involving the loss of teeth by the gradual destruction of ligaments that hold teeth in their sockets in the jawbone. The disease usually results from an increased concentration of bacteria in the pocket, or sulcus, between the gums and teeth. These bacteria produce acids and other byproducts, which enlarge the sulcus by eroding the gums and the periodontal ligaments. The sulcus normally has a depth of 1 to 2 millimeters, but in patients with early stages of periodontal disease, it has a depth of 3 to 5 millimeters. By measuring the depth of the sulcus, periodontists can have a good assessment of the disease s progress. Presently, there are no reliable clinical indicators of periodontal disease activity, and the best available diagnostic aid, periodontal probing, can only measure what has already been lost. A method for detecting small increments of periodontal ligament breakdown would permit earlier diagnosis and intervention with less costly and time-consuming therapy, while overcoming the problems associated with conventional probing. The painful, conventional method for probing may be destined for the archives of dental history, thanks to the development of ultrasound probing technologies. The roots of ultrasound probes are in an ultrasound-based time-of-flight technique routinely used to measure material thickness and length in the Nondestructive Evaluation Sciences Laboratory at Langley Research Center. The primary applications of that technology have been for corrosion detection and bolt tension measurements (Spinoff 2005). This ultrasound measurement system was adapted to the Periodontal Structures Mapping System, invented at Langley by John A. Companion, under the supervision of Dr. Joseph S. Heyman. Support of the research and development that led to this invention was provided by NASA s Technology Applications Engineering Program and by the Naval Institute for Dental and Biomedical Research, in Great Lakes, Illinois.
Effect of local drug delivery in chronic periodontitis patients: A meta-analysis
Kalsi, Rupali; Vandana, K. L.; Prakash, Shobha
2011-01-01
Periodontal diseases are multi-factorial in etiology, and bacteria are one among these etiologic agents. Thus, an essential component of therapy is to eliminate or control these pathogens. This has been traditionally accomplished through mechanical means (scaling and root planing (SRP)), which is time-consuming, difficult, and, sometimes, ineffective. From about the past 30 years, locally delivered, anti-infective pharmacological agents, most recently employing sustained-release vehicles, have been introduced to achieve this goal. This systematic review is an effort to determine the efficacy of the currently available anti-infective agents, with and without concurrent SRP, in controlling chronic periodontitis. Four studies were included, which were all randomized controlled trials, incorporating a total patient population of 80, with 97 control sites and 111 test sites. A meta-analysis completed on these four studies including SRP and local sustained-release agents compared with SRP alone indicated significant adjunctive probing depth (PD) reduction for 10% Doxycycline hycylate (ATRIDOX), minocycline hydrochloride (ARESTIN), tetracycline hydrochloride (PERIODONTAL PLUS AB), and chlorhexidine gluconate (PERIOCHIP). Essentially, all studies reported substantial reductions in gingival inflammation, plaque scores, and bleeding indices, which were similar in both the control and the experimental groups. Use of antimicrobial sustained-release systems as an adjunct to SRP does not result in significant patient-centered adverse events. Local drug delivery combined with SRP appears to provide additional benefits in PD reduction compared with SRP alone. PMID:22368351
DeLong, Edward F.; Taylor, Lance Trent; Marsh, Terence L.; Preston, Christina M.
1999-01-01
Fluorescent in situ hybridization (FISH) using rRNA-specific oligonucleotide probes has emerged as a popular technique for identifying individual microbial cells. In natural samples, however, the signal derived from fluor-labeled oligonucleotide probes often is undetectable above background fluorescence in many cells. To circumvent this difficulty, we applied fluorochrome-labeled polyribonucleotide probes to identify and enumerate marine planktonic archaea and bacteria. The approach greatly enhanced the sensitivity and applicability of FISH with seawater samples, allowing confident identification and enumeration of planktonic cells to ocean depths of 3,400 m. Quantitative whole-cell hybridization experiments using these probes accounted for 90 to 100% of the total 4′,6-diamidino-2-phenylindole (DAPI)-stained cells in most samples. As predicted in a previous study (R. Massana, A. E. Murray, C. M. Preston, and E. F. DeLong, Appl. Environ. Microbiol. 63:50–56, 1997), group I and II marine archaea predominate in different zones in the water column, with maximal cell densities of 105/ml. The high cell densities of archaea, extending from surface waters to abyssal depths, suggest that they represent a large and significant fraction of the total picoplankton biomass in coastal ocean waters. The data also show that the vast majority of planktonic prokaryotes contain significant numbers of ribosomes, rendering them easily detectable with polyribonucleotide probes. These results imply that the majority of planktonic cells visualized by DAPI do not represent lysed cells or “ghosts,” as was suggested in a previous report. PMID:10584017
Evaluation of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.; Nark, D. M.; Howerton, B. M.
2015-01-01
This paper explores the effects of variable-depth geometry on the amount of noise reduction that can be achieved with acoustic liners. Results for two variable-depth liners tested in the NASA Langley Grazing Flow Impedance Tube demonstrate significant broadband noise reduction. An impedance prediction model is combined with two propagation codes to predict corresponding sound pressure level profiles over the length of the Grazing Flow Impedance Tube. The comparison of measured and predicted sound pressure level profiles is sufficiently favorable to support use of these tools for investigation of a number of proposed variable-depth liner configurations. Predicted sound pressure level profiles for these proposed configurations reveal a number of interesting features. Liner orientation clearly affects the sound pressure level profile over the length of the liner, but the effect on the total attenuation is less pronounced. The axial extent of attenuation at an individual frequency continues well beyond the location where the liner depth is optimally tuned to the quarter-wavelength of that frequency. The sound pressure level profile is significantly affected by the way in which variable-depth segments are distributed over the length of the liner. Given the broadband noise reduction capability for these liner configurations, further development of impedance prediction models and propagation codes specifically tuned for this application is warranted.
Zybutz, M D; Laurell, L; Rapoport, D A; Persson, G R
2000-03-01
Different types of barriers are used in guided tissue regenerative procedures. This prospective study compared resorbable citric acid ester softened polylactic acid membranes (RM) and non-resorbable expanded polytetrafluoroethylene (ePTFE) barriers (NRM) in GTR treatment of intrabony defects. 29 subjects were randomly assigned to the RM group or NRM group. Each patient received one GTR procedure. An open flap debridement (FD) was performed at another site 2 weeks later to evaluate healing potential. Clinical treatment outcomes were finally evaluated 12 months after surgery for changes of pocket depth PD, probing attachment level PAL, and probing bone level PBL, and radiographically for bone change using standardised radiographs. No differences in healing patters after surgery were found between patients in the 2 study groups as evaluated from the FD surgical procedures. NRM treated sites showed less signs of post-surgical inflammation during the 1st 4 weeks of healing than did RM treated sites (p<0.05). GTR-treated defects in the RM group, initially 7.0+/-2.2 mm deep, showed PD reduction of 3.3+/-2.2 mm, PAL gain of 2.4+/-1.8 mm, PBL gain of 2.4+/-3.7 mm (28%) and a radiographic bone fill of 2.3+/-2.4 mm. Defects treated with the NRM exhibited PD reduction of 3.1+/-2.1 mm, PAL gain of 2.4+/-0.8 mm, PBL gain of 2.2+/-1.7 mm (25%) and a radiographic bone fill of 3.3+/-2.2 mm. All improvements were statistically significant (p<0.01) but there was no difference between RM and NRM treatments for any of the efficacy variables. The results of this study indicated that there was no clinically significant difference in treatment outcomes following GTR treatment of intrabony defects with citric acid ester softened polylactic acid membranes as compared to ePTFE barriers. The overall mean inter-proximal vertical bone defect fill at 12 months as assessed from intra-oral radiographs was 44% of the original mean defect depth. Thus, no clinically significant difference in treatment outcomes was observed following GTR treatment of intrabony defects with citric acid ester softened polylactic acid membranes or ePTFE barriers.
Di Luca, Massimiliano; Domini, Fulvio; Caudek, Corrado
2007-05-01
In two experiments, observers were asked to judge the relative depth of a probe and one or two flanker dots. In Experiment 1, we found that such judgments were influenced by the properties of adjacent image regions, that is, by the amount of angular rotation of a surrounding cloud of dots. In Experiment 2, we found that the properties of the adjacent image regions affected the precision of the observers' judgments. With only the probe and the flanker dots presented in isolation, the precision of observers' judgments was much lower than when probe and the flanker dots were surrounded by a rigidly-connected cloud of dots. Conversely, a non-rigid rotation of the surrounding dots was detrimental to the precision of visual performance. These data can be accounted for by the Intrinsic Constraint model [Domini, F., Caudek, C., & Tassinari, H. (2006). Stereo and motion information are not independently processed by the visual system. Vision Research, 46, 1707-1723], which incorporates the mutual constraints relating disparity and motion signals. The present investigation does not show that the rigidity constraint affects the visual interpretation of motion information alone. Rather, our results show that perceptual performance is affected by the linear relation between disparity and velocity signals, when both depth-cues are present and the distal object is, in fact, rigid.
Endoscopically assisted tunnel approach for minimally invasive corticotomies: a preliminary report.
Hernández-Alfaro, Federico; Guijarro-Martínez, Raquel
2012-05-01
The dental community has expressed low acceptance of traditional corticotomy techniques for corticotomy-facilitated orthodontics. These procedures are time consuming, entail substantial postoperative morbidity and periodontal risks, and are often perceived as highly invasive. A total of 114 interdental sites were treated in nine consecutive patients. Under local anesthesia, a tunnel approach requiring one to three vertical incisions per arch (depending on the targeted teeth) was used. Piezosurgical corticotomies and elective bone augmentation procedures were performed under endoscopic assistance. Postoperative cone-beam computerized tomography evaluation was used to confirm adequate corticotomy depth. Procedures were completed in a mean time of 26 minutes. Follow-up evaluations revealed no loss of tooth vitality, no changes in periodontal probing depth, good preservation of the papillae, and no gingival recession. No evidence of crestal bone height reduction or apical root resorption was detected. The tunnel approach minimizes soft-tissue debridement and permits effective cortical cuts. The combination of piezosurgery technique with endoscopic assistance provides a quick, reliable means to design and perform these corticotomies while maximizing root integrity preservation. Moreover, the sites needing bone augmentation are selected under direct vision. Compared to traditional corticotomies, this procedure has manifest advantages in surgical time, technical complexity, patient morbidity, and periodontium preservation.
Does periodontitis affect diabetes incidence and haemoglobin A1c change? An 11-year follow-up study.
Kebede, T G; Pink, C; Rathmann, W; Kowall, B; Völzke, H; Petersmann, A; Meisel, P; Dietrich, T; Kocher, T; Holtfreter, B
2017-11-22
As periodontitis may contribute to the pathogenesis of diabetes, the effects of periodontitis on diabetes incidence and HbA1c change was quantified in a prospective cohort. Data from an 11-year follow-up of the Study of Health in Pomerania were analyzed to evaluate the effects of periodontitis on incident diabetes and long-term HbA1c changes in 2047 subjects aged 20-81years. Diabetes was based on self-reported physician diagnoses, antidiabetic medication use, or HbA1c≥6.5% or non-fasting blood glucose levels ≥11.1mmol/L. To assess periodontal status, periodontal pockets were probed, and their depth and clinical attachment levels measured. For both measures, means and percentages of sites≥3mm were calculated. In addition, all probing depths≥4mm were summed (cumulative probing depth). Modified Poisson and multivariable linear models were applied, adjusted for age, gender, highest level of general education, marital status, waist circumference, physical activity, smoking status and follow-up time. Over a mean follow-up period of 11.1years, 207 subjects developed diabetes. Baseline mean clinical attachment levels (CAL) and probing depths (PPD) were not significantly associated with either diabetes incidence [mean CALs, fourth quartile, incidence rate ratio=0.819, 95% confidence interval (CI): 0.489-1.370; P=0.446] or long-term changes in HbA1c (mean CAL, fourth quartile, β=-0.086, 95% CI: -0.187, -0.016; P=0.098). Sensitivity analyses using alternative exposure definitions confirmed these results. Contrary to the currently available literature, no convincing evidence was found of any potential association between periodontitis and diabetes incidence or HbA1c change. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
López, Lydia M; Guerra, María Elena
2015-03-01
The aim of this study was to determine the caries rate and periodontal status in a sample of pregnant women with HIV+ infections from Puerto Rico. A pilot study was conducted on a cross sectional convenience sample of 25 pregnant women with HIV+ infections from Puerto Rico who visit the CEMI clinic (Centro de Estudios Materno Infantil) at the University of Puerto Rico. The women subjects were evaluated for caries, DMFT (D: Decay tooth; M: Missing tooth due to caries; F: Filled tooth) index, oral lesions associated with HIV+/AIDS and periodontal disease parameters, with a Florida probe by a calibrated dentist on periodontal indexes such as as bleeding on probing, CEJ (cemento-enamel junction) and pocket depth. Periodontal disease was classified as having 4 sites with pocket depth greater than 4 mm and caries were identified following the Radike criteria. Data was statistically analyzed using the SSPS Program (Statistical Software Program for Social Sciences) and descriptive statistics were calculated. Mean DT (decayed teeth), MT (missing teeth due to caries), FT (filled teeth) and DMFT (decay, missing and filled teeth) were 4.8, 1.86, 5.3 and 12, respectively; mean sites of bleeding on probing=12.06; mean sites with pocket depth>4 mm=6.95 and mean sites with loss of attachment greater than 4 mm=7.66. [Almost 50% of the patients had generalized chronic periodontitis. A 72% prevalence of periodontal disease was found. No oral lesions related to HIV+/AIDS were reported. CD4 and viral load was statistically associated with bleeding on probing and severe signs of periodontal disease. High levels of dental disease were found in pregnant women with HIV+/AIDS infections from Puerto Rico, and these women were in need of substantial dental services.
Gümüş, Pinar; Buduneli, Nurcan; Cetinkalp, Sevki; Hawkins, Samuel I; Renaud, Diane; Kinane, Denis F; Scott, David A
2009-09-01
The purpose of this study was to evaluate and compare salivary concentrations of reduced, oxidized glutathione, uric acid, ascorbic acid, and total antioxidant capacity in subjects with diabetes and systemically healthy subjects with inflammatory periodontal disease. Sixteen patients with type 1 diabetes mellitus (DM), 25 patients with type 2 DM, and 24 systemically healthy patients, all with inflammatory periodontal disease, were recruited. Whole-saliva samples were obtained, and full-mouth clinical periodontal measurements, including plaque index, probing depth, gingival recession, clinical attachment level, and bleeding on probing, were recorded at six sites per tooth. Saliva flow rate and salivary levels of reduced and oxidized glutathione, vitamin C, uric acid, and total antioxidant capacity were determined. Data were analyzed statistically by non-parametric tests. The subjects with type 2 DM had fewer teeth and more sites with probing depths >4 mm than the patients with type 1 DM (both P <0.01). The mean salivary reduced-glutathione concentration was lower in patients with type 1 DM than in the other two groups (both P <0.05). No significant differences in the salivary concentrations of the other antioxidants measured were found among the groups (P >0.05). Oxidized glutathione levels in the patients with type 1 DM were significantly lower than in the systemically healthy group (P = 0.007). In both groups with diabetes, salivary reduced-glutathione levels correlated positively with probing depth, and total antioxidant capacity correlated with salivary flow rate (P <0.01). The decrease in salivary reduced-glutathione levels in patients with type 1 DM may have a role in periodontal tissue destruction by predisposing tissues to oxidative stress.
Optimal probes for withdrawal of uncontaminated fluid samples
NASA Astrophysics Data System (ADS)
Sherwood, J. D.
2005-08-01
Withdrawal of fluid by a composite probe pushed against the face z =0 of a porous half-space z >0 is modeled assuming incompressible Darcy flow. The probe is circular, of radius a, with an inner sampling section of radius αa and a concentric outer guard probe αa
Novel laser contact probe for periodontal treatment
NASA Astrophysics Data System (ADS)
Watanabe, Hisashi; Kataoka, Kenzo; Ishikawa, Isao
2001-04-01
Application of the erbium: YAG laser to periodontal treatment has been attempted and preferable results have been reported for calculus removal, vaporization of granulation tissue, periodontal pocket sterilization and so on. However, it has been difficult to reach and treat some conditions involving complex root morphology and furcated rots with conventional probes. The new broom probe was designed and tested to overcome these obstacles. The probe was made of 20 super-fine optical fibers bound into a broom shape. The experiments were carried out to evaluate the destructive power of a single fiber and to examine the morphology of tissue destruction and the accessibility to a bifurcated root of a human tooth using the broom probe. The Er:YAG laser prototype was used. A flat specimen plate was made by cutting the root of a cow tooth and then attached to an electrically operated table and irradiated under various conditions. The specimens were examined with both an optical and scanning electron microscope. The irradiated surfaces were also examined with a roughness meter. An irradiation applied with a single fiber with an energy level of 1 to 1.5 mJ at its tip results in a destruction depth of 3 to 24 micrometers . The optimum conditions for the fibers of this probe was 1.0 mJ at 10 pps and a scanning speed of 100 mm/min. No part of the tooth surface remained un-irradiated after using the broom probe to cover the surface 5 times parallel to the tooth axis and then five times at a 30 degree angle to the previous irradiation at a power of 20 mJ at 10 pps. Also curved and irregular surface were destroyed to a maximum depth of 19 micrometers . In conclusion, these results suggest that the broom probe would be applicable for periodontal laser treatments even if the tooth surface has a complex and irregular shape.
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact test is the... a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac impact... surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000 kg-cm2...
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact test is the... a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac impact... surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000 kg-cm2...
49 CFR 572.200 - Instrumentation and test conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mass moment of inertia of 3646 kg-cm2. (b) The test probe for the lateral abdomen impact test is the... a minimum mass moment of inertia of 3646 kg-cm2. (c) The test probe for the pelvis-iliac impact... surface 50.8 × 88.9 mm for a depth of at least 76 mm and a minimum mass moment of inertia of 5000 kg-cm2...
Oskooei, Ali; Kaigala, Govind V
2017-06-01
We present a method for nonintrusive localization and reagent delivery on immersed biological samples with topographical variation on the order of hundreds of micrometers. Our technique, which we refer to as the deep-reaching hydrodynamic flow confinement (DR-HFC), is simple and passive: it relies on a deep-reaching hydrodynamic confinement delivered through a simple microfluidic probe design to perform localized microscale alterations on substrates as deep as 600 μm. Designed to scan centimeter-scale areas of biological substrates, our method passively prevents sample intrusion by maintaining a large gap between the probe and the substrate. The gap prevents collision of the probe and the substrate and reduces the shear stress experienced by the sample. We present two probe designs: linear and annular DR-HFC. Both designs comprise a reagent-injection aperture and aspiration apertures that serve to confine the reagent. We identify the design parameters affecting reagent localization and depth by DR-HFC and study their individual influence on the operation of DR-HFC numerically. Using DR-HFC, we demonstrate localized binding of antihuman immunoglobulin G (IgG) onto an activated substrate at various depths from 50 to 600 μm. DR-HFC provides a readily implementable approach for noninvasive processing of biological samples applicable to the next generation of diagnostic and bioanalytical devices.
Orthodontic treatment in patients with aggressive periodontitis.
Carvalho, Cássio Volponi; Saraiva, Luciana; Bauer, Flávio Paim Falcão; Kimura, Rui Yoshio; Souto, Maria Luisa Silveira; Bernardo, Carlos Cheque; Pannuti, Cláudio Mendes; Romito, Giuseppe Alexandre; Pustiglioni, Francisco Emílio
2018-04-01
Aggressive periodontitis (AP) is a condition that promotes breakdown of the periodontal tissues in a short time. In severe cases, pathologic migration of teeth and tooth loss can occur, producing esthetic and functional problems for the patient. Orthodontic treatment may be recommended to restore esthetics and masticatory function. We assessed the effects of orthodontic movement in the periodontal tissues of treated patients with AP. Ten subjects (ages 25.0 ± 5.22 years) with AP received periodontal treatment followed by orthodontic treatment. Maintenance sessions were performed monthly under a strict dental biofilm control. They were compared with 10 periodontally healthy subjects (ages 22.9 ± 5.23 years) who received orthodontic treatment. Probing pocket depth, clinical attachment level, bleeding on probing, and dental plaque index were measured at baseline, after orthodontic treatment, and after 4 months. Statistical analysis showed improvement in all clinical parameters between baseline and 4 months after orthodontic treatment: probing pocket depth (0.29 mm), clinical attachment level (0.38 mm), bleeding on probing (4.0%), and dental plaque index (11%). The periodontal parameters of the AP patients remained stable during orthodontic treatment under strict biofilm control. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Innovations in Sampling Pore Fluids From Deep-Sea Hydrate Sites
NASA Astrophysics Data System (ADS)
Lapham, L. L.; Chanton, J. P.; Martens, C. S.; Schaefer, H.; Chapman, N. R.; Pohlman, J. W.
2003-12-01
We have developed a sea-floor probe capable of collecting and returning undecompressed pore water samples at in situ pressures for determination of dissolved gas concentrations and isotopic values in deep-sea sediments. In the summer of 2003, we tested this instrument in sediments containing gas hydrates off Vancouver Island, Cascadia Margin from ROPOS (a remotely operated vehicle) and in the Gulf of Mexico from Johnson-Sea-Link I (a manned submersible). Sediment push cores were collected alongside the probe to compare methane concentrations and stable carbon isotope compositions in decompressed samples vs. in situ samples obtained by probe. When sufficient gas was available, ethane and propane concentrations and isotopes were also compared. Preliminary data show maximum concentrations of dissolved methane to be 5mM at the Cascadia Margin Fish Boat site (850m water depth) and 12mM in the Gulf of Mexico Bush Hill hydrate site (550m water depth). Methane concentrations were, on average, five times as high in probe samples as in the cores. Carbon isotopic values show a thermogenic input and oxidative effects approaching the sediment-water interface at both sites. This novel data set will provide information that is critical to the understanding of the in situ processes and environmental conditions controlling gas hydrate occurrences in sediments.
Coupled Ablation, Heat Conduction, Pyrolysis, Shape Change and Spallation of the Galileo Probe
NASA Technical Reports Server (NTRS)
Milos, Frank S.; Chen, Y.-K.; Rasky, Daniel J. (Technical Monitor)
1995-01-01
The Galileo probe enters the atmosphere of Jupiter in December 1995. This paper presents numerical methodology and detailed results of our final pre-impact calculations for the heat shield response. The calculations are performed using a highly modified version of a viscous shock layer code with massive radiation coupled with a surface thermochemical ablation and spallation model and with the transient in-depth thermal response of the charring and ablating heat shield. The flowfield is quasi-steady along the trajectory, but the heat shield thermal response is dynamic. Each surface node of the VSL grid is coupled with a one-dimensional thermal response calculation. The thermal solver includes heat conduction, pyrolysis, and grid movement owing to surface recession. Initial conditions for the heat shield temperature and density were obtained from the high altitude rarefied-flow calculations of Haas and Milos. Galileo probe surface temperature, shape, mass flux, and element flux are all determined as functions of time along the trajectory with spallation varied parametrically. The calculations also estimate the in-depth density and temperature profiles for the heat shield. All this information is required to determine the time-dependent vehicle mass and drag coefficient which are necessary inputs for the atmospheric reconstruction experiment on board the probe.
Development of background-free tame fluorescent probes for intracellular live cell imaging
Alamudi, Samira Husen; Satapathy, Rudrakanta; Kim, Jihyo; Su, Dongdong; Ren, Haiyan; Das, Rajkumar; Hu, Lingna; Alvarado-Martínez, Enrique; Lee, Jung Yeol; Hoppmann, Christian; Peña-Cabrera, Eduardo; Ha, Hyung-Ho; Park, Hee-Sung; Wang, Lei; Chang, Young-Tae
2016-01-01
Fluorescence labelling of an intracellular biomolecule in native living cells is a powerful strategy to achieve in-depth understanding of the biomolecule's roles and functions. Besides being nontoxic and specific, desirable labelling probes should be highly cell permeable without nonspecific interactions with other cellular components to warrant high signal-to-noise ratio. While it is critical, rational design for such probes is tricky. Here we report the first predictive model for cell permeable background-free probe development through optimized lipophilicity, water solubility and charged van der Waals surface area. The model was developed by utilizing high-throughput screening in combination with cheminformatics. We demonstrate its reliability by developing CO-1 and AzG-1, a cyclooctyne- and azide-containing BODIPY probe, respectively, which specifically label intracellular target organelles and engineered proteins with minimum background. The results provide an efficient strategy for development of background-free probes, referred to as ‘tame' probes, and novel tools for live cell intracellular imaging. PMID:27321135
Periodontal status during pregnancy and postpartum
2017-01-01
Objectives Different studies have documented an association between periodontal disease and low birth-weight delivery. Hence, knowledge of periodontal status during pregnancy and postpartum is important in order to reduce the risks of both diseases. This study aimed to analyze periodontal status at successive stages of pregnancy and 3–6 weeks postpartum in women with initial periodontal alterations. Materials and methods Ninety-six pregnant women were examined at 8–10 weeks (pregnancy diagnosis, baseline), 21–23 weeks and 34–36 weeks of gestation and at 40 days postpartum to record plaque scores, clinically assessed gingival inflammation and probing depth (mean depth and % sites with depth >3 mm). Bivariate and multivariate analyses were performed. Type 1 (α) error was established at 0.05 Results Plaque Index increased (p = 0.043) throughout pregnancy (baseline, 42%±0.18); 21–23 weeks, 42.6%±0.14; 34–36 weeks, 45.6%±0.13 and decreased postpartum (44.8%±0–13). Gingival Index increased (p<0.001) throughout pregnancy (baseline, 56.7%±0.20; 21–23 weeks, 66.36%±0.17; 34–36 weeks, 74.5%±0.18) and decreased postpartum (59.3%±0.21). Probing Depth increased (p<0.001) throughout pregnancy (baseline, 2.51±0.05; 21–23 weeks, 2.63±0.053; 34–36 weeks 2.81±0.055) and decreased postpartum (2.54±0.049). Percentage of sites with Probing Depth >3 mm increased (p<0.001) throughout pregnancy (baseline, 17.6%±0.16; 21–23 weeks, 23.9%±0.17; 34–36 weeks, 31.1%±0.17) and decreased postpartum (21.2%±0.17) but remained significantly (p<0.02) higher than at baseline. Conclusion Periodontal status deteriorates during gestation but improves postpartum. PMID:28538740
NASA Astrophysics Data System (ADS)
Dai, L.; Sorkin, V.; Zhang, Y. W.
2017-04-01
We perform molecular dynamics simulations to investigate molecular structure alternation and friction behavior of heterogeneous polymer (perfluoropolyether) surfaces using a nanoscale probing tip (tetrahedral amorphous carbon). It is found that depending on the magnitude of the applied normal force, three regimes exist: the shallow depth-sensing (SDS), deep depth-sensing (DDS), and transitional depth-sensing (TDS) regimes; TDS is between SDS and DDS. In SDS, the tip is floating on the polymer surface and there is insignificant permanent alternation in the polymer structure due to largely recoverable atomic deformations, and the surface roughness profile can be accurately measured. In DDS, the tip is plowing through the polymer surface and there is significant permanent alternation in the molecular structure. In this regime, the lateral friction force rises sharply and fluctuates violently when overcoming surface pile-ups. In SDS, the friction can be described by a modified Amonton’s law including the adhesion effect; meanwhile, in DDS, the adhesion effect is negligible but the friction coefficient is significantly higher. The underlying reason for the difference in these regimes rests upon different contributions by the repulsion and attraction forces between the tip and polymer surfaces to the friction force. Our findings here reveal important insights into lateral depth-sensing on heterogeneous polymer surfaces and may help improve the precision of depth-sensing devices.
Kakar, Ashish; Kakar, Kanupriya
2013-05-01
To compare relief from dentin hypersensitivity (DH) after use of dentifrices formulated with potassium nitrate or fluoride. For the study, DH evaluations were conducted with the Jay Sensitivity Sensor Probe (Jay Probe), a novel tactile hypersensitivity instrument, in conjunction with three other DH methods, i.e. Yeaple probe (tactile), air blast, and the Visual Analog Scale (VAS). Adults (n = 100) who presented two teeth with DH and met study criteria were enrolled for this double-blind, randomized, parallel, controlled clinical trial conducted in an outpatient setting. DH evaluations at baseline were conducted by the tactile, air blast, and VAS methods. Subjects were randomly assigned a dentifrice formulated with 5% potassium nitrate and 1,000 ppm fluoride (as sodium monofluorophosphate) (Colgate Sensitive toothpaste; Test) or a commercially available fluoride dentifrice with 1,000 ppm fluoride as sodium monofluorophosphate (Colgate Cibaca toothpaste; Negative control). Subjects were recalled for DH evaluations after 4 and 8 weeks of product use. 85 subjects completed the entire study with evaluable results. Both treatments resulted in significant reductions in DH from baseline to all recall visits. In comparison to the Negative control, subjects in the Test group demonstrated significantly greater reductions for all DH evaluations at both 4 and 8 weeks (P < 0.05). Average tactile DH scores at week 8 for the Test and Negative control groups were 36.25 and 15.24 with the Yeaple probe and 35 and 12.43 with the Jay probe. Correspondingly, subjects in the Test group demonstrated significantly greater reductions in air blast and VAS responses for DH than those in the Negative control group (P < 0.05).
BIOTIC AND ABIOTIC CONTRIBUTIONS TO REDUCTIVE TRANSFORMATION OF ORGANIC POLLUTANTS
The relative contributions of biotic and abiotic reductive transformation reactions were probed in two anoxic freshwater sediments by following the transformation of nitrobenzene, and 2,4 dichlorophenol (compounds with different one electron reduction potentials). The sediments d...
NASA Astrophysics Data System (ADS)
Awad, Somia; Chen, Hongmin; Maina, Grace; Lee, L. James; Gu, Xiaohong; Jean, Y. C.
2010-03-01
Positron annihilation spectroscopy (PAS) has been developed as a novel probe to characterize the sub-nanometer defect, free volume, profile from the surface, interfaces, and to the bulk in polymeric materials when a variable mono-energy slow positron beam is used. Free-volume hole sizes, fractions, and distributions are measurable as a function of depth at the high precision. PAS has been successfully used to study the interfacial properties of polymeric nanocomposites at different chemical bonding. In nano-scale thin polymeric films, such as in PS/SiO2, and PU/ZnO, significant variations of Tg as a function of depth and of wt% oxide are observed. Variations of Tg are dependent on strong or weak interactions between polymers and nano-scale oxides surfaces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Hong; Liu, Sheng; Center for Advanced Studied in Photonics Research
2014-05-26
We temporally resolved the ultrafast mid-infrared transmission modulation of quantum cascade lasers (QCLs) using a near-infrared pump/mid-infrared probe technique at room temperature. Two different femtosecond wavelength pumps were used with photon energy above and below the quantum well (QW) bandgap. The shorter wavelength pump modulates the mid-infrared probe transmission through interband transition assisted mechanisms, resulting in a high transmission modulation depth and several nanoseconds recovery lifetime. In contrast, pumping with a photon energy below the QW bandgap induces a smaller transmission modulation depth but much faster (several picoseconds) recovery lifetime, attributed to intersubband transition assisted mechanisms. The latter ultrafast modulationmore » (>60 GHz) could provide a potential way to realize fast QCL based free space optical communication.« less
Deep brain two-photon NIR fluorescence imaging for study of Alzheimer's disease
NASA Astrophysics Data System (ADS)
Chen, Congping; Liang, Zhuoyi; Zhou, Biao; Ip, Nancy Y.; Qu, Jianan Y.
2018-02-01
Amyloid depositions in the brain represent the characteristic hallmarks of Alzheimer's disease (AD) pathology. The abnormal accumulation of extracellular amyloid-beta (Aβ) and resulting toxic amyloid plaques are considered to be responsible for the clinical deficits including cognitive decline and memory loss. In vivo two-photon fluorescence imaging of amyloid plaques in live AD mouse model through a chronic imaging window (thinned skull or craniotomy) provides a mean to greatly facilitate the study of the pathological mechanism of AD owing to its high spatial resolution and long-term continuous monitoring. However, the imaging depth for amyloid plaques is largely limited to upper cortical layers due to the short-wavelength fluorescence emission of commonly used amyloid probes. In this work, we reported that CRANAD-3, a near-infrared (NIR) probe for amyloid species with excitation wavelength at 900 nm and emission wavelength around 650 nm, has great advantages over conventionally used probes and is well suited for twophoton deep imaging of amyloid plaques in AD mouse brain. Compared with a commonly used MeO-X04 probe, the imaging depth of CRANAD-3 is largely extended for open skull cranial window. Furthermore, by using two-photon excited fluorescence spectroscopic imaging, we characterized the intrinsic fluorescence of the "aging pigment" lipofuscin in vivo, which has distinct spectra from CRANAD-3 labeled plaques. This study reveals the unique potential of NIR probes for in vivo, high-resolution and deep imaging of brain amyloid in Alzheimer's disease.
Optical switching property of electromagnetically induced transparency in a Λ system
NASA Astrophysics Data System (ADS)
Zhang, Lianshui; Wang, Jian; Feng, Xiaomin; Yang, Lijun; Li, Xiaoli; Zhao, Min
2008-12-01
In this paper we study the coherent transient property of a Λ-three-level system (Ωd = 0) and a quasi- Λ -four-level system (Ωd>0). Optical switching of the probe field can be achieved by applying a pulsed coupling field or rf field. In Λ -shaped three-level system, when the coupling field was switched on, there is a almost total transparency of the probe field and the time required for the absorption changing from 90% to 10% of the maximum absorption is 2.9Γ0 (Γ0 is spontaneous emission lifetime). When the coupling field was switched off, there is an initial increase of the probe field absorption and then gradually evolves to the maximum of absorption of the two-level absorption, the time required for the absorption of the system changing from 10% to 90% is 4.2Γ0. In four-level system, where rf driving field is used as switching field, to achieve the same depth of the optical switching, the time of the optical switching is 2.5Γ0 and 6.1Γ0, respectively. The results show that with the same depth of the optical switching, the switch-on time of the four-level system is shorter than that of the three-level system, while the switch-off time of the four-level system is longer. The depth of the optical switching of the four-level system was much larger than that of the three-level system, where the depth of the optical switching of the latter is merely 14.8% of that of the former. The speed of optical switching of the two systems can be increased by the increase of Rabi frequency of coupling field or rf field.
Kruger, Rozanne; Stonehouse, Welma; von Hurst, Pamela Ruth; Coad, Jane
2012-04-01
To investigate if the addition of an in-depth interview focused on cultural dietary practices could improve the quality of dietary data from food records among South Asian women in New Zealand. Cross-sectional data were collected from 134 South Asian women (≥20 years), living in Auckland. Dietary data were collected using four-day food records. Nutritional analysis revealed 33.6% under-reporting of energy intakes. All women were recalled for an in-depth probing interview focused on culture-specific foods and dietary practices. The interview revealed extensive use of dairy products and plant oils. The nutrient content of the food record alone and the food record plus interview were compared; median energy intakes were 6,852 kJ vs 7,246 kJ (p<0.001); under-reporting decreased by 14.2%, and total fat and protein intakes (g/day) increased (p<0.001). Estimates of poly- and mono-unsaturated fatty acids increased significantly (p<0.001) due to greater use of plant oils due to greater use of plant oils replacing saturated fatty acid-rich fats in food preparation. A significant increase (17%) (p<0.001) in calcium intake reflects the higher dairy intake identified with the interview. The addition of an in-depth probing interview to a four-day food record enhanced food intake reporting. Self-reported dietary assessments in immigrant population groups require quality control for accuracy. Methods to ensure high-quality dietary data are essential to assess health outcomes and to inform public health interventions, especially in immigrant populations. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.
NASA Astrophysics Data System (ADS)
Blanks, J. K.; Hintz, C. J.; Chandler, G. T.; Shaw, T. J.; McCorkle, D. C.; Bernhard, J. M.
2007-12-01
Mg/Ca and Sr/Ca were analyzed from core-top individual Hoeglundina elegans aragonitic tests collected from three continental slope depths within the South Carolina and Little Bahama Bank continental slope environs (220 m to 1084 m). Our study utilized only individuals that labeled with the vital probe CellTracker Green - unlike bulk core-top material often stained with Rose Bengal, which has known inconsistencies in distinguishing live from dead foraminifera. DSr x 10 values were consistently 1.74 $ pm 0.23 across all sampling depths. The analytical error in DSr values (0.7%) determined by ICP-MS between repeated measurements on individual H. elegans tests across all depths was less than analytical error on repeated measurements from standards. Variation in DSr values was not directly explained by a linear temperature relationship (p=0.0003, R2=0.44) over the temperature range of 4.9-11.4°C with a sensitivity of 59.8 μmol/mol/1°C. The standard error by regressing DSr across temperature yields + 3.4°C, which is nearly 3x greater that reported in previous studies. Sr/Ca was more sensitive for calibrating temperature than Mg/Ca in H. elegans. Observed scatter in DSr was too great across individuals of the same size and of different sizes to resolve ontogenetic effects. However, higher DSr values were associated with smaller individuals and warmer/shallower sampling depths. The highest DSr values were observed at the intermediate sampling depth (~600 m). No significant ontogenetic relationship was found across DSr values in different sized individuals due to tighter overall constrained variance; however lower DSr values were observed from several smaller individuals. Several dead tests of H. elegans showed no significant differences in DSr values compared to live specimens cleaned by standard cleaning methods, unlike higher dead than live DMg values observed for the same individuals. There were no significant deviations in DSr across batches cleaned on separate days, unlike the observed sensitivity of DMg across batches. A subset of samples were reductively cleaned (hydrazine solution); and exhibited DMg values within analytical precision of those observed for non-reductively cleaned samples. Therefore, deviations in DMg values resulting from the removal of the reductive cleaning step did not explain analytical errors greater than published values for Mg/Ca or the high variance across same sized individuals. Variation in DMg values across the same cleaning methods and from dead individuals suggests the need for a careful look into how foraminiferal aragonite should be processed. These findings provide evidence that both Mg and Sr in benthic foraminiferal aragonite reflect factors in addition to temperature and pressure that may interfere with absolute temperature calibrations. Funded by NSF OCE 0351029, OCE 0437366, and OCE-0350794.
Jang, Yun Jung; Lee, Jihye; Jeong, Jeung-Hyun; Lee, Kang-Bong; Kim, Donghwan; Lee, Yeonhee
2018-05-01
To enhance the conversion performance of solar cells, a quantitative and depth-resolved elemental analysis of photovoltaic thin films is required. In this study, we determined the average concentration of the major elements (Cu, In, Ga, and Se) in fabricated Cu(In,Ga)Se2 (CIGS) thin films, using inductively coupled plasma atomic emission spectroscopy, X-ray fluorescence, and wavelengthdispersive electron probe microanalysis. Depth profiling results for CIGS thin films with different cell efficiencies were obtained using secondary ion mass spectrometry and Auger electron spectroscopy to compare the atomic concentrations. Atom probe tomography, a characterization technique with sub-nanometer resolution, was used to obtain three-dimensional elemental mapping and the compositional distribution at the grain boundaries (GBs). GBs are identified by Na increment accompanied by Cu depletion and In enrichment. Segregation of Na atoms along the GB had a beneficial effect on cell performance. Comparative analyses of different CIGS absorber layers using various analytical techniques provide us with understanding of the compositional distributions and structures of high efficiency CIGS thin films in solar cells.
NASA Astrophysics Data System (ADS)
Fallah, Alireza
2010-02-01
Objective: This study compared the effect of 980 Diode laser + scaling and root planing (SRP) versus SRP alone in the treatment of chronic periodontitis. Method: 21 healthy patients with moderate periodontitis with a probing depth of at least 5mm were included in the study. A total of 42 sites were treated during 6weeks with a combination of 980 Diode laser and SRP (21 sites) or SRP alone (21 sites). The gingival index (GI), probing pocket depth (PPD) and bleeding on probing (BOP) were examined at the baseline and after 6 weeks after the start of treatment. Results: Both groups showed statistically significant improvements in GI, BOP and PPD after treatment. The results also showed significant improvement from laser+ SRP group to SRP alone group. Conclusion: The present data suggest that treatment of chronic periodontitis with either 980 Diode laser + SRP or SRP alone results in statistically significant improvements in the clinical parameters. The combination of 980 Diode laser irradiation in the gingival sulcus and SRP, was significantly better as compared to SRP alone.
Development of Mackintosh Probe Extractor
NASA Astrophysics Data System (ADS)
Rahman, Noor Khazanah A.; Kaamin, Masiri; Suwandi, Amir Khan; Sahat, Suhaila; Jahaya Kesot, Mohd
2016-11-01
Dynamic probing is a continuous soil investigation technique, which is one of the simplest soil penetration test. It basically consist of repeatedly driving a metal tipped probe into the ground using a drop weight of fixed mass and travel. Testing was carried out continuously from ground level to the final penetration depth. Once the soil investigation work done, it is difficult to pull out the probe rod from the ground, due to strong soil structure grip against probe cone and prevent the probe rod out from the ground. Thus, in this case, a tool named Extracting Probe was created to assist in the process of retracting the probe rod from the ground. In addition, Extracting Probe also can reduce the time to extract the probe rod from the ground compare with the conventional method. At the same time, it also can reduce manpower cost because only one worker involve to handle this tool compare with conventional method used two or more workers. From experiment that have been done we found that the time difference between conventional tools and extracting probe is significant, average time difference is 155 minutes. In addition the extracting probe can reduce manpower usage, and also labour cost for operating the tool. With all these advantages makes this tool has the potential to be marketed.
Research on mutual influence of Cherenkov-type probes within the ISTTOK tokamak chamber
NASA Astrophysics Data System (ADS)
Jakubowski, L.; Plyusnin, V. V.; Malinowski, K.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Fernandes, H.; Silva, C.; Figueiredo, H.; Jakubowski, M. J.
2014-12-01
The paper describes an influence of a Cherenkov-type probe, which is used for measurements of fast electron streams inside the ISTTOK chamber, on other probes and behaviour of a plasma ring. The reported study shows that such a probe situated near the plasma column has a strong influence on signals from another Cherenkov probe, and can cause a considerable reduction of electron-induced signals. This effect does not depend on positions of the probes in relation to the limiter. Measurements of hard X-ray (HXR) emission show that the deeply immersed Cherenkov probe can also influence on the limiter . Under specific experimental conditions such a Cherenkov probe can play the role of a new limiter and change the plasma configuration.
Short circuit current changes in electron irradiated GaAlAs/GaAs solar cells
NASA Technical Reports Server (NTRS)
Walker, G. H.; Conway, E. J.
1978-01-01
Heteroface p-GaAlAs/p-GaAs/n-GaAs solar cells with junction depths of 0.8, 1.5, and 4 microns were irradiated with 1 MeV electrons. The short-circuit current for the 4 micron junction depth cells is significantly reduced by the electron irradiation. Reduction of the junction depth to 1.5 microns improves the electron radiation resistance of the cells while further reduction of the junction depth to 0.8 microns improves the stability of the cells even more. Primary degradation is in the blue region of the spectrum. Considerable recovery of lost response is obtained by annealing the cells at 200 C. Computer modeling shows that the degradation is caused primarily by a reduction in the minority carrier diffusion length in the p-GaAs.
A micro-CMM with metrology frame for low uncertainty measurements
NASA Astrophysics Data System (ADS)
Brand, Uwe; Kirchhoff, Juergen
2005-12-01
A conventional bridge-type coordinate measuring machine (CMM) with an opto-tactile fibre probe for the measurement of microstructures has been equipped with a metrology frame in order to reduce its measurement uncertainty. The frame contains six laser interferometers for high-precision position and guiding deviation measurements, a Zerodur cuboid with three measuring surfaces for the laser interferometers to which the fibre probe is fixed, and an invar frame which supports the measuring objects and to which the reference mirrors of the interferometers are fixed. The orthogonality and flatness deviations of the Zerodur measuring surfaces have been measured and taken into account in the equation of motion of the probing sphere. As a first performance test, the flatness of an optical flat has been measured with the fibre probe. Measuring-depth-dependent and probing-force-dependent shifts of the probing position were observed. In order to reduce the scattering of the probing points, 77 measurements were averaged for one coordinate point to be measured. This has led to measuring times of several hours for one plane and strong thermal drifts of the measured probing points.
New tip design and shock wave pattern of electrohydraulic probes for endoureteral lithotripsy.
Vorreuther, R
1993-02-01
A new tip design of a 3.3F electrohydraulic probe for endoureteral lithotripsy was evaluated in comparison to a regular probe. The peak pressure, as well as the slope of the shock front, depend solely on the voltage. Increasing the capacity leads merely to broader pulses. A laser-like short high-pressure pulse has a greater impact on stone disintegration than a corresponding broader low-pressure pulse of the same energy. Using the regular probe, only positive pressures were obtained. Pressure distribution around the regular tip was approximately spherical, whereas the modified probe tip "beamed" the shock wave to a great extent. In addition, a negative-pressure half-cycle was added to the initial positive peak pressure, which resulted in a higher maximal pressure amplitude. The directed shock wave had a greater depth of penetration into a model stone. Thus, the ability of the new probe to destroy harder stones especially should be greater. The trauma to the ureter was reduced when touching the wall tangentially. No difference in the effect of the two probes was seen when placing the probe directly on the mucosa.
Miniature all-optical probe for photoacoustic and ultrasound dual-modality imaging
NASA Astrophysics Data System (ADS)
Li, Guangyao; Guo, Zhendong; Chen, Sung-Liang
2018-02-01
Photoacoustic (PA) imaging forms an image based on optical absorption contrasts with ultrasound (US) resolution. In contrast, US imaging is based on acoustic backscattering to provide structural information. In this study, we develop a miniature all-optical probe for high-resolution PA-US dual-modality imaging over a large imaging depth range. The probe employs three individual optical fibers (F1-F3) to achieve optical generation and detection of acoustic waves for both PA and US modalities. To offer wide-angle laser illumination, fiber F1 with a large numerical aperture (NA) is used for PA excitation. On the other hand, wide-angle US waves are generated by laser illumination on an optically absorbing composite film which is coated on the end face of fiber F2. Both the excited PA and backscattered US waves are detected by a Fabry-Pérot cavity on the tip of fiber F3 for wide-angle acoustic detection. The wide angular features of the three optical fibers make large-NA synthetic aperture focusing technique possible and thus high-resolution PA and US imaging. The probe diameter is less than 2 mm. Over a depth range of 4 mm, lateral resolutions of PA and US imaging are 104-154 μm and 64-112 μm, respectively, and axial resolutions of PA and US imaging are 72-117 μm and 31-67 μm, respectively. To show the imaging capability of the probe, phantom imaging with both PA and US contrasts is demonstrated. The results show that the probe has potential for endoscopic and intravascular imaging applications that require PA and US contrast with high resolution.
Coleman, Michael; McCormick, Adam; Laskin, Daniel M
2011-02-01
This study assessed the incidence of periodontal defects on the distal aspect of maxillary second molars after extraction of impacted maxillary third molars. Subjects enrolled in this institutional review board-approved prospective study consisted of healthy young patients having extraction of at least 1 asymptomatic impacted maxillary third molar adjacent to a second molar. Preoperative periodontal probing data were collected from 4 sites (midbuccal, distobuccal, midpalatal, and distopalatal) on each adjacent second molar, and a similar probing examination was performed at a mean of 6 months postoperatively. All subjects were treated under general anesthesia or conscious sedation by upper-level residents in the outpatient clinic. Twenty subjects with a total of 38 impacted maxillary third molars were treated. There were 9 male subjects (45%) and 11 female subjects (55%), with a mean age of 17 years (range, 14-22 years). The mean follow-up interval was 6 months, with a range of 3 to 15 months. Of the 152 probing sites measured, 92 (61%) decreased, 56 (37%) remained unchanged, and only 4 (2.6%) increased. A decrease in probing depth of 1 mm was found in 35 (23%) of the sites, a decrease of 2 mm was seen in 32 (21%), and 25 (16%) decreased by 3 mm or more. Of the 152 sites probed, 4 (2.6%) increased by 1 or 2 mm. Extraction of the impacted maxillary third molar does not result in significant periodontal defects on the distal aspect of the adjacent second molar, and in many cases it results in an improvement of the probing depths on these teeth. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Mathur, A. B.; Collinsworth, A. M.; Reichert, W. M.; Kraus, W. E.; Truskey, G. A.
2001-01-01
This study evaluated the hypothesis that, due to functional and structural differences, the apparent elastic modulus and viscous behavior of cardiac and skeletal muscle and vascular endothelium would differ. To accurately determine the elastic modulus, the contribution of probe velocity, indentation depth, and the assumed shape of the probe were examined. Hysteresis was observed at high indentation velocities arising from viscous effects. Irreversible deformation was not observed for endothelial cells and hysteresis was negligible below 1 microm/s. For skeletal muscle and cardiac muscle cells, hysteresis was negligible below 0.25 microm/s. Viscous dissipation for endothelial and cardiac muscle cells was higher than for skeletal muscle cells. The calculated elastic modulus was most sensitive to the assumed probe geometry for the first 60 nm of indentation for the three cell types. Modeling the probe as a blunt cone-spherical cap resulted in variation in elastic modulus with indentation depth that was less than that calculated by treating the probe as a conical tip. Substrate contributions were negligible since the elastic modulus reached a steady value for indentations above 60 nm and the probe never indented more than 10% of the cell thickness. Cardiac cells were the stiffest (100.3+/-10.7 kPa), the skeletal muscle cells were intermediate (24.7+/-3.5 kPa), and the endothelial cells were the softest with a range of elastic moduli (1.4+/-0.1 to 6.8+/-0.4 kPa) depending on the location of the cell surface tested. Cardiac and skeletal muscle exhibited nonlinear elastic behavior. These passive mechanical properties are generally consistent with the function of these different cell types.
Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vold, E.
1997-12-31
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples.more » Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the boreholes reported here confirm the broad features seen previously in moisture profiles at Area G, a near-surface region with large moisture variability, a very dry region at greater depths, and a moisture spike at the vapor phase notch (VPN). This feature is located near the interface between the vitrified and vitrified stratigraphic units and near the base of the mesa. This report describes the in-field calibration methods used for the neutron moisture probe measurements and summarizes preliminary results of the monitoring program in the in-situ monitoring network at Area G. Reported results include three main areas: calibration studies, profiles from each of the vertical boreholes at Area G, and time-dependent variations in a select subset of boreholes. Results are reported here for the vertical borehole network. Results from the horizontal borehole network will be described when available.« less
2012-07-01
Jitter results from electronic noise and from the fact that the shape of the detector signal used for timing can vary considerably depending on the...photomultiplier technology, several “probe” detectors were developed. It was predicted, and subsequently shown, that probes having good position...high spatial resolution for prostate imaging. Practical proof-of-concept detectors with good depth-of-interactions resolution have been developed and
Changes in the periodontal condition after replacement of swaged crowns by metal.
Plotniece-Baranovska, Anita; Soboleva, Una; Rogovska, Irena; Apse, Peteris
2006-01-01
Evidence based clinical studies have shown exact recommended design for artificial crown reconstruction with acceptable long-term results taking into an account the biological price. Previous histological and clinical studies proved that fixed prostheses might influence the periodontal condition of crowned teeth, if not all biological criteria have been considered. The aim of the present study was to assess the periodontal condition of the crowned teeth after stainless steel swaged crowns were replaced by cast metal ceramic crowns. Participants were selected at the Institute of Stomatology, Stradin's University. Selection criteria included need to replace existing swaged crowns by metal ceramic crowns for patients with absence of any systemic disease. Following symptoms of periodontal condition were examined - presence of inflammation (clinical signs, probing) and pocket depth. Assessments were carried out at four different points of time (first appointment after replacement existing swaged crowns by temporary crowns; two weeks after cementation of permanent metal ceramic restoration; after three month; after six month). Overall bleeding score "2" and "3" at the first measurement was observed in majority of study population. Bleeding scores between the 1st and the 4th measurement was significantly lower (p<0.01). The same trend was observed also in the reduction of pocket depth. Overall mean value of pocket depth gradually decreased from the 1st till the 4th measurement. Replacement of swaged crowns by metal ceramic improves gingival health and leads to better long-term prognosis for restored teeth. It is recommended that swaged crowns be replaced with more biologically friendly crowns.
α- and β-Proteobacteria Control the Consumption and Release of Amino Acids on Lake Snow Aggregates
Schweitzer, Bernhard; Huber, Ingrid; Amann, Rudolf; Ludwig, Wolfgang; Simon, Meinhard
2001-01-01
We analyzed the composition of aggregate (lake snow)-associated bacterial communities in Lake Constance from 1994 until 1996 between a depth of 25 m and the sediment surface at 110 m by fluorescent in situ hybridization with rRNA-targeted oligonucleotide probes of various specificity. In addition, we experimentally examined the turnover of dissolved amino acids and carbohydrates together with the microbial colonization of aggregates formed in rolling tanks in the lab. Generally, between 40 and more than 80% of the microbes enumerated by DAPI staining (4′,6′-diamidino-2-phenylindole) were detected as Bacteria by the probe EUB338. At a depth of 25 m, 10.5% ± 7.9% and 14.2% ± 10.2% of the DAPI cell counts were detected by probes specific for α- and β-Proteobacteria. These proportions increased to 12.0% ± 3.3% and 54.0% ± 5.9% at a depth of 50 m but decreased again at the sediment surface at 110 m to 2.7% ± 1.4% and 41.1% ± 8.4%, indicating a clear dominance of β-Proteobacteria at depths of 50 and 110 m, where aggregates have an age of 3 to 5 and 8 to 11 days, respectively. From 50 m to the sediment surface, cells detected by a Cytophaga/Flavobacteria-specific probe (CF319a) comprised increasing proportions up to 18% of the DAPI cell counts. γ-Proteobacteria always comprised minor proportions of the aggregate-associated bacterial community. Using only two probes highly specific for clusters of bacteria closely related to Sphingomonas species and Brevundimonas diminuta, we identified between 16 and 60% of the α-Proteobacteria. In addition, with three probes highly specific for close relatives of the β-Proteobacteria Duganella zoogloeoides (formerly Zoogloea ramigera), Acidovorax facilis, and Hydrogenophaga palleroni, bacteria common in activated sludge, 42 to 70% of the β-Proteobacteria were identified. In the early phase (<20 h) of 11 of the 15 experimental incubations of aggregates, dissolved amino acids were consumed by the aggregate-associated bacteria from the surrounding water. This stage was followed by a period of 1 to 3 days during which dissolved amino acids were released into the surrounding water, paralleled by an increasing dominance of β-Proteobacteria. Hence, our results show that lake snow aggregates are inhabited by a community dominated by a limited number of α- and β-Proteobacteria, which undergo a distinct succession. They successively decompose the amino acids bound in the aggregates and release substantial amounts into the surrounding water during aging and sinking. PMID:11157226
Diop, Mamadou; St. Lawrence, Keith
2013-01-01
Time-resolved (TR) techniques provide a means of discriminating photons based on their time-of-flight. Since early arriving photons have a lower probability of probing deeper tissue than photons with long time-of-flight, time-windowing has been suggested as a method for improving depth sensitivity. However, TR measurements also contain instrument contributions (instrument-response-function, IRF), which cause temporal broadening of the measured temporal point-spread function (TPSF) compared to the true distribution of times-of-flight (DTOF). The purpose of this study was to investigate the influence of the IRF on the depth sensitivity of TR measurements. TPSFs were acquired on homogeneous and two-layer tissue-mimicking phantoms with varying optical properties. The measured IRF and TPSFs were deconvolved using a stable algorithm to recover the DTOFs. The microscopic Beer-Lambert law was applied to the TPSFs and DTOFs to obtain depth-resolved absorption changes. In contrast to the DTOF, the latest part of the TPSF was not the most sensitive to absorption changes in the lower layer, which was confirmed by computer simulations. The improved depth sensitivity of the DTOF was illustrated in a pig model of the adult human head. Specifically, it was shown that dynamic absorption changes obtained from the late part of the DTOFs recovered from TPSFs acquired by probes positioned on the scalp were similar to absorption changes measured directly on the brain. These results collectively demonstrate that this method improves the depth sensitivity of TR measurements by removing the effects of the IRF. PMID:23504445
Child–Adult Differences in Using Dual-Task Paradigms to Measure Listening Effort
Charles, Lauren M.; Ricketts, Todd A.
2017-01-01
Purpose The purpose of the project was to investigate the effects modifying the secondary task in a dual-task paradigm to measure objective listening effort. To be specific, the complexity and depth of processing were increased relative to a simple secondary task. Method Three dual-task paradigms were developed for school-age children. The primary task was word recognition. The secondary task was a physical response to a visual probe (simple task), a physical response to a complex probe (increased complexity), or word categorization (increased depth of processing). Sixteen adults (22–32 years, M = 25.4) and 22 children (9–17 years, M = 13.2) were tested using the 3 paradigms in quiet and noise. Results For both groups, manipulations of the secondary task did not affect word recognition performance. For adults, increasing depth of processing increased the calculated effect of noise; however, for children, results with the deep secondary task were the least stable. Conclusions Manipulations of the secondary task differentially affected adults and children. Consistent with previous findings, increased depth of processing enhanced paradigm sensitivity for adults. However, younger participants were more likely to demonstrate the expected effects of noise on listening effort using a secondary task that did not require deep processing. PMID:28346816
Diffusion induced atomic islands on the surface of Ni/Cu nanolayers
NASA Astrophysics Data System (ADS)
Takáts, Viktor; Csik, Attila; Hakl, József; Vad, Kálmán
2018-05-01
Surface islands formed by grain-boundary diffusion has been studied in Ni/Cu nanolayers by in-situ low energy ion scattering spectroscopy, X-ray photoelectron spectroscopy, scanning probe microscopy and ex-situ depth profiling based on ion sputtering. In this paper a new experimental approach of measurement of grain-boundary diffusion coefficients is presented. Appearing time of copper atoms diffused through a few nanometer thick nickel layer has been detected by low energy ion scattering spectroscopy with high sensitivity. The grain-boundary diffusion coefficient can be directly calculated from this appearing time without using segregation factors in calculations. The temperature range of 423-463 K insures the pure C-type diffusion kinetic regime. The most important result is that surface coverage of Ni layer by Cu atoms reaches a maximum during annealing and stays constant if the annealing procedure is continued. Scanning probe microscopy measurements show a Volmer-Weber type layer growth of Cu layer on the Ni surface in the form of Cu atomic islands. Depth distribution of Cu in Ni layer has been determined by depth profile analysis.
NASA Astrophysics Data System (ADS)
Van Cleve, J. E.; Grillmair, C. J.
2001-01-01
The Galileo probe gathered data in the Jovian atmosphere for about one hour before its destruction. For a wider perceptive on the atmospheres of the outer planets, multiple, long-lived observations platforms would be useful. In this paper we examine the basic physics of hot-air ballooning in a hydrogen atmosphere, using plutonium RTGs as a heat source. We find that such balloons are buoyant at a sufficiently great depth in these atmospheres, and derive equations for the balloon radius and mass of plutonium required as a function of atmospheric mass density and balloon material parameters. We solve for the buoyancy depth given the constraint that each probe may contain 1.0 kg of Pu, and find that the temperature at that depth is too great for conventional electronics (>70 C) for Jupiter and Saturn. However, the Pu mass constraint and the operating temperature constraint are consistent for Uranus and Neptune, and this concept may be applicable to those planets. Additional information is contained in the original extended abstract.
High sensitivity optical molecular imaging system
NASA Astrophysics Data System (ADS)
An, Yu; Yuan, Gao; Huang, Chao; Jiang, Shixin; Zhang, Peng; Wang, Kun; Tian, Jie
2018-02-01
Optical Molecular Imaging (OMI) has the advantages of high sensitivity, low cost and ease of use. By labeling the regions of interest with fluorescent or bioluminescence probes, OMI can noninvasively obtain the distribution of the probes in vivo, which play the key role in cancer research, pharmacokinetics and other biological studies. In preclinical and clinical application, the image depth, resolution and sensitivity are the key factors for researchers to use OMI. In this paper, we report a high sensitivity optical molecular imaging system developed by our group, which can improve the imaging depth in phantom to nearly 5cm, high resolution at 2cm depth, and high image sensitivity. To validate the performance of the system, special designed phantom experiments and weak light detection experiment were implemented. The results shows that cooperated with high performance electron-multiplying charge coupled device (EMCCD) camera, precision design of light path system and high efficient image techniques, our OMI system can simultaneously collect the light-emitted signals generated by fluorescence molecular imaging, bioluminescence imaging, Cherenkov luminance and other optical imaging modality, and observe the internal distribution of light-emitting agents fast and accurately.
Insufficient evidence for photodynamic therapy use in periodontitis.
Herrera, David
2011-01-01
The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Health and Psychosocial Instruments, HealthSTAR (OVID), Allied and Complementary Medicine and the International Pharmaceutical Abstracts. Abstracts from 2007 to 2009 of the annual meetings of the American Academy of Periodontology, International Association of Dental Research and the American Association of Dental Research. Randomised and quasi-randomised studies reported in any language comparing PDT as a primary or adjunctive therapy to no treatment, placebo or scaling and root planing (SRP). Eligible studies were those that included participants over 18 years of age and who had periodontitis, and where the primary outcome measurement was clinical attachment loss (CAL) and changes in probing depth. Two reviewers reviewed, assessed and rated study quality and extracted relevant data. It is not reported how these data were collated. The quality of included studies was assessed according to Cochrane risk of bias domains. Mean difference (MD) and 95% confidence intervals (CI) were extracted. Data were combined in a meta-analysis where possible using the random-effects model. Homogeneity was assessed using the Cochrane test and heterogeneity assessed using I(2). Five studies at moderate to high risk of bias were included. The studies differed markedly in design and were clinically heterogenous. Studies that compared PDT to no treatment found no difference in CAL whereas those that compared PDT plus SRP (n=26) to those receiving just SRP (n=26) gave a MD of 0.34 mm with 95% CI 0.05 to 0.63 mm. Three studies that compared PDT alone to SRP alone showed a reduction in probing depth in favour of SRP (MD -0.21, 95% CI -0.40-0.02). In three studies that compared PDT plus SRP to SRP alone the MD was 0.25 mm (95% CI: 0.04 to 0.45 mm). There is insufficient evidence that photodynamic therapy as an independent treatment or as an adjunct to scaling and root planning is superior to SRP alone.
Duque, Thais M; Prado, Maira; Herrera, Daniel R; Gomes, Brenda P F A
2018-03-23
The aim of the present study was to investigate the effects of a calcium hydroxide-based intracanal medication (ICM) on periodontal and endodontic infectious/inflammatory contents and on periodontal clinical parameters in teeth with primary periodontal lesion and secondary endodontic involvement. Ten patients with abnormal pulp test results and deep probing depth derived from primary periodontal disease with secondary endodontic involvement were included. Samples were collected from root canals (RC) and periodontal pockets (PP) in order to investigate the microbiological status, levels of endotoxin (LPS), cytokines, and matrix metalloproteinases (MMP), before and after ICM. PCR was used for microbiological assessment. The kinetic-chromogenic LAL assay was used for LPS quantification. Quantikine ELISA kits were used for measurement of IL-1 α, IL-1 β, TNF-α, PGE 2 , MMP-2, MMP-3, MMP-8, MMP-9, and MMP-13 levels. The statistical analyses were made using the Friedman and Wilcoxon tests (p < 0.05). T test was used to compare data on periodontal characteristics. ICM did not reduce the number of microorganisms in PP and RC, except for Fusobacterium nucleatum in RC. There was a significant reduction in LPS, MMPs, IL-1 β, and TNF-α levels in PP after ICM. In RC, LPS, MMP13, PGE 2 , and IL-1β levels remained unaltered (p > 0.05); however, the levels of the other MMPs and cytokines were reduced (p < 0.05). After 1 year of the root canal treatment, tooth mobility was significantly reduced (p ≤ 0.05). The use of a calcium hydroxide-based ICM showed positive effects for periodontal treatment prognosis, as it reduced LPS, cytokine, and MMP levels in periodontal pockets. Patients presenting deep probing depth and undergoing periodontal treatment for at least 6 months, with no positive response to periodontal therapy, might benefit with the endodontic treatment.
Lou, Zhangrong; Li, Peng; Han, Keli
2015-01-01
Selenium is a biologically important trace element and acts as an active center of glutathione peroxidase (GPx). GPx is the important antioxidant enzyme to protect organisms from oxidative damage via catalyzing the reaction between ROS and glutathione (GSH). Mimicking the oxidation-reduction cycles of the versatile selenium core in GPx, we can develop fluorescence probes to detect oxidation and reduction events in living systems. The cellular redox balance between hypochloric acid (HClO) and hydrogen sulfide (H2S) has broad implications in human health and diseases, such as Alzheimer's disease (AD). Therefore, to further investigate the roles of this redox balance and understand the pathogenesis of neurodegenerative diseases, it is necessary to detect the redox state between HClO and H2S in real time. We have developed a reversible fluorescence probe MPhSe-BOD for imaging of the redox cycle between HClO and H2S based on oxidation and reduction of selenide in living cells.
Morse, Michael S.; Lu, Ning; Godt, Jonathan W.; Revil, André; Coe, Jeffrey A.
2012-01-01
Accurate estimation of the soil thickness distribution in steepland drainage basins is essential for understanding ecosystem and subsurface response to infiltration. One important aspect of this characterization is assessing the heavy and antecedent rainfall conditions that lead to shallow landsliding. In this paper, we investigate the direct current (DC) resistivity method as a tool for quickly estimating soil thickness over a steep (33–40°) zero-order basin in the Oregon Coast Range, a landslide prone region. Point measurements throughout the basin showed bedrock depths between 0.55 and 3.2 m. Resistivity of soil and bedrock samples collected from the site was measured for degrees of saturation between 40 and 92%. Resistivity of the soil was typically higher than that of the bedrock for degrees of saturation lower than 70%. Results from the laboratory measurements and point-depth measurements were used in a numerical model to evaluate the resistivity contrast at the soil-bedrock interface. A decreasing-with-depth resistivity contrast was apparent at the interface in the modeling results. At the field site, three transects were surveyed where coincident ground truth measurements of bedrock depth were available, to test the accuracy of the method. The same decreasing-with-depth resistivity trend that was apparent in the model was also present in the survey data. The resistivity contour of between 1,000 and 2,000 Ωm that marked the top of the contrast was our interpreted bedrock depth in the survey data. Kriged depth-to-bedrock maps were created from both the field-measured ground truth obtained with a soil probe and interpreted depths from the resistivity tomography, and these were compared for accuracy graphically. Depths were interpolated as far as 16.5 m laterally from the resistivity survey lines with root mean squared error (RMSE) = 27 cm between the measured and interpreted depth at those locations. Using several transects and analysis of the subsurface material properties, the direct current (DC) resistivity method is shown to be able to delineate bedrock depth trends within the drainage basin.
[Impact of volatile sulphur compounds in periodontal pockets on initial periodontal therapy].
Li, Xiao-Jun; Dong, Ling-Ling; Kong, Jing-Jia
2008-07-01
To investigate the relationship of volatile sulphur compounds((VSC)levels in periodontal pockets with severity of periodontitis, and the impact of VSC on the result of initial periodontal therapy. Twenty-five patients with chronic periodontitis(CP)(13 males and 12 females with average age of 35) were included in this study. Clinical periodontal parameters, plaque index, probing depth(PD), attachment loss(AL), and bleeding on probing(BOP) were recorded before and 3 months after the initial therapy. VSC levels were measured with a portable monitor in a digital score ranging from 0.0 to 5.0. All of 5 054 sites for 840 teeth were included in this study. Before treatment the percentage of VSC-positive sites was 17.1%, 52.3% and 86.0% for shallow (PD<3 mm), moderate(PD 4-6 mm) and deep (PD>7 mm) pocket, respectively (P<0.001). In most VSC-positive sites the VSC levels were<1.0. Percentage of sites with a high VSC levels was significantly different among three groups (P<0.01). All clinical parameters in VSC-negative sites were reduced significantly following the initial therapy. The reduction of PD and AL in VSC-positive sites by treatment was less marked than that in VSC-negative sites. VSC in periodontal pockets may be a potential indicator for detecting severity of CP and a useful predictor for therapeutic success.
Lulic, Martina; Leiggener Görög, Isabelle; Salvi, Giovanni E; Ramseier, Christoph A; Mattheos, Nikolaos; Lang, Niklaus P
2009-08-01
Single photodynamic therapy (PDT) has been effective in initial periodontal therapy, but only improved bleeding on probing (BoP) in maintenance patients after a single use. Repeated PDT has not been addressed. To study the possible added benefits of repeated adjunctive PDT to conventional treatment of residual pockets in patients enrolled in periodontal maintenance. Ten maintenance patients with 70 residual pockets [probing pocket depth (PPD)>or=5 mm] were randomly assigned for treatment five times in 2 weeks (Days 0, 1, 2, 7, 14) with PDT (test) or non-activated laser (control) following debridement. The primary outcome variable was PPD, and the secondary variables were clinical attachment level (CAL) and BoP. These were assessed at 3, 6 and 12 months following the interventions. Greater PPD reductions were observed in the test (-0.67 +/- 0.34; p=0.01) compared with the control patients (-0.04 +/- 0.33; NS) after 6 months. Significant CAL gain (+0.52 +/- 0.31; p=0.01) was noted for the test, but not in the control (-0.27 +/- 0.52; NS) patients after 6 months. BoP percentages decreased significantly in test (97-64%, 67%, 77%), but not control patients after 3, 6 and 12 months. Repeated (five times) PDT adjunctive to debridement yielded improved clinical outcomes in residual pockets in maintenance patients. The effects were best documented after 6 months.
Alshehri, Mohammad; Alshail, Faisal; Alqahtani, Sami H; Aloriny, Tawfeeg Saleh; Alsharif, Abdulhakim; Kujan, Omar
2015-09-01
The aim of the present short-term follow-up study was to assess the effects of scaling and root planing (SRP) with or without adjunctive use of an essential-oil-based mouthwash in the treatment of periodontal inflammation in smokers. In total, 120 individuals were divided into 2 groups. In Group-1, 60 smokers with periodontal inflammation received SRP alone; and in Group-2, 60 smokers with periodontal inflammation received adjunct essential-oil mouthwash therapy. Periodontal parameters (plaque index [PI], bleeding-on-probing [BOP], and probing pocket depth [PD] ≥ 4 mm) were assessed at baseline and after 90 days of treatment. There was no significant difference in periodontal parameters (PI, BOP, and PD ≥ 4 mm) among participants in Group-1 and -2. Participants in both groups showed significant reductions in PI (P < 0.01), BOP (P < 0.01), and PD ≥ 4 mm (P < 0.01) at follow-up compared to baseline. At 90 days of follow-up, PI (P < 0.05), BOP (P < 0.05), and PD ≥ 4 mm (P < 0.05) were significantly higher in Group-1 compared to Group-2. SRP with adjunct essential-oil mouthwash therapy is more effective in the treatment of periodontal inflammation in smokers as compared to when SRP is performed alone.
Coordinate metrology using scanning probe microscopes
NASA Astrophysics Data System (ADS)
Marinello, F.; Savio, E.; Bariani, P.; Carmignato, S.
2009-08-01
New positioning, probing and measuring strategies in coordinate metrology are needed for the accomplishment of true three-dimensional characterization of microstructures, with uncertainties in the nanometre range. In the present work, the implementation of scanning probe microscopes (SPMs) as systems for coordinate metrology is discussed. A new non-raster measurement approach is proposed, where the probe is moved to sense points along free paths on the sample surface, with no loss of accuracy with respect to traditional raster scanning and scan time reduction. Furthermore, new probes featuring long tips with innovative geometries suitable for coordinate metrology through SPMs are examined and reported.
Detection of Real Flaw using Uniform Eddy Current Multi-probe
NASA Astrophysics Data System (ADS)
Fukuoka, Katsuhiro; Hashimoto, Mitsuo
The establishment of the nondestructive inspection technology with plant structures has been stimulated by the recent occurrence of cracks in the nuclear power plant structures. In this research, a uniform eddy current multi-probe to apply to the complex structure and inspect the cracks at high-speed data acquisition was developed. Pick-up coils of the developed probe were arranged on a flexible printed circuit board. This probe was able to obtain clear signal for an EDM (electro-discharge machining) slit with 0.5 mm depth and distinguish EDM slits arranged at 2 mm intervals. It was confirmed that the SCC (stress corrosion cracking) of real flaw was able to be detected with developed uniform eddy current multi-probe by using the ferrite core for the exciting coil and considering the impedance matching of the exciting coil and the flaw detection device.
High-resolution scanning Hall probe microscopy
NASA Astrophysics Data System (ADS)
Hallen, Hans D.; Hess, H. F.; Chang, A. M.; Pfeiffer, Loren N.; West, Kenneth W.; Mitzi, David B.
1993-06-01
A high resolution scanning Hall probe microscope is used to spatially resolve vortices in high temperature superconducting Bi2Sr2CaCu2O8+(delta) crystals. We observe a partially ordered vortex lattice at several different applied magnetic fields and temperatures. At higher temperatures, a limited amount of vortex re-arrangement is observed, but most vortices remain fixed for periods long compared to the imaging time of several hours even at temperatures as high as 75 degree(s)K (the superconducting transition temperature for these crystals is approximately 84 degree(s)K). A measure of these local magnetic penetration depth can be obtained from a fit to the surface field of several neighboring vortices, and has been measured as a function of temperature. In particular, we have measured the zero temperature penetration depth and found it to be 275 +/- 40 nm.
Dual-radiolabeled nanoparticle probes for depth-independent in vivo imaging of enzyme activation
NASA Astrophysics Data System (ADS)
Black, Kvar C. L.; Zhou, Mingzhou; Sarder, Pinaki; Kuchuk, Maryna; Al-Yasiri, Amal Y.; Gunsten, Sean P.; Liang, Kexian; Hennkens, Heather M.; Akers, Walter J.; Laforest, Richard; Brody, Steven L.; Cutler, Cathy S.; Achilefu, Samuel
2018-02-01
Quantitative and noninvasive measurement of protease activities has remained an imaging challenge in deep tissues such as the lungs. Here, we designed a dual-radiolabeled probe for reporting the activities of proteases such as matrix metalloproteinases (MMPs) with multispectral single photon emission computed tomography (SPECT) imaging. A gold nanoparticle (NP) was radiolabeled with 125I and 111In and functionalized with an MMP9-cleavable peptide to form a multispectral SPECT imaging contrast agent. In another design, incorporation of 199Au radionuclide into the metal crystal structure of gold NPs provided a superior and stable reference signal in lungs, and 111In was linked to the NP surface via a protease-cleavable substrate, which can serve as an enzyme activity reporter. This work reveals strategies to correlate protease activities with diverse pathologies in a tissue-depth independent manner.
Turbulence Measurements from a Moored Platform at Mid-Depth in a Swift Tidal Channel
NASA Astrophysics Data System (ADS)
Hay, Alex; Lueck, Rolf; Wolk, Fabian; McMillan, Justine
2014-05-01
Results are presented from a turbulence experiment with a 3-m long streamlined floatation body, instrumented with velocity shear probes, fast-response thermistors, a 1 MHz Acoustic Doppler Current Profiler (AD2CP), and an Acoustic Doppler Velocimeter (ADV). The system was deployed over seven tidal cycles at mid-depth in a 30-m deep tidal channel in the lower Bay of Fundy, Canada. Peak flow speeds exceeded 2 m s-1, and while 10-min time scale average speeds were similar between ebb and flood, the variances were markedly higher during flood. Turbulent kinetic energy (TKE) dissipation rates measured with the shear probes exhibit a pronounced flood/ebb contrast: O(10-4) W kg-1 peak values during flood, but lower by an order of magnitude during ebb. Dissipation rates follow u3 scaling over a wide range of flow speeds between 0.5 and 2.5 m s-1. Below 0.5 m s-1 an asymmetry in the mounting arrangement caused the floatation body to pitch upward, biasing the measured dissipation values high. The ADV on the platform registered mean speed - used to implement Taylor's hypothesis - which was corroborated with the platform-mounted ADCP. Additional ADCPs were also deployed on a nearby bottom pod, sampling at turbulence resolving rates - up to 8 Hz. Comparisons between the shear probe and acoustic estimates of the TKE spectrum and dissipation rate - at comparable depths - are presented.
SUPERGRANULES AS PROBES OF THE SUN'S MERIDIONAL CIRCULATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hathaway, David H., E-mail: david.hathaway@nasa.gov
2012-11-20
Recent analysis revealed that supergranules (convection cells seen at the Sun's surface) are advected by the zonal flows at depths equal to the widths of the cells themselves. Here we probe the structure of the meridional circulation by cross-correlating maps of the Doppler velocity signal using a series of successively longer time lags between maps. We find that the poleward meridional flow decreases in amplitude with time lag and reverses direction to become an equatorward return flow at time lags >24 hr. These cross-correlation results are dominated by larger and deeper cells at longer time lags. (The smaller cells havemore » shorter lifetimes and do not contribute to the correlated signal at longer time lags.) We determine the characteristic cell size associated with each time lag by comparing the equatorial zonal flows measured at different time lags with the zonal flows associated with different cell sizes from a Fourier analysis. This association gives a characteristic cell size of {approx}50 Mm at a 24 hr time lag. This indicates that the poleward meridional flow returns equatorward at depths >50 Mm-just below the base of the surface shear layer. A substantial and highly significant equatorward flow (4.6 {+-} 0.4 m s{sup -1}) is found at a time lag of 28 hr corresponding to a depth of {approx}70 Mm. This represents one of the first positive detections of the Sun's meridional return flow and illustrates the power of using supergranules to probe the Sun's internal dynamics.« less
Clinical parameters and aMMP-8-concentrations in gingival crevicular fluid in pregnancy gingivitis.
Ehlers, Vicky; Callaway, Angelika; Hortig, Wajiha; Kasaj, Adrian; Willershausen, Brita
2013-01-01
During pregnancy hormonal changes may increase the risk for developing gingivitis. The aim of this study was to evaluate the signs of gingival inflammation and the enzyme activity of matrix metalloproteinase-8 (aMMP-8) in the gingival crevicular fluid of pregnant women. After approval by the ethics commission, a total of 40 volunteers participated in the study; group 1 (n = 20, age: 32 +/- 4 years) with pregnant women, and group 2 (n = 20, age: 30 +/- 10 years) with age-matched non-pregnant women as controls. After obtaining anamnestic data, the dental examination included assessment of oral hygiene, gingival inflammation, probing pocket depth, and recession. Gingival crevicular fluid was collected from both groups. A quantitative determination of aMMP-8 concentrations in the gingival crevicular fluid samples was performed. The aMMP-8 values of group 1 were higher (median 6.25 ng/mL aMMP-8 eluate) compared with group 2 (median 3.88 ng/mL aMMP-8 eluate), but the difference was not statistically significant (p = 0.265). Group 1 showed significantly increased probing pocket depths (p = 0.001). Gingival inflammation was present in 80% of the pregnant women, but only in 40% of the control subjects. It was shown that during pregnancy changes related to periodontal health could be observed. Higher aMMP-8 values, elevated probing pocket depths, and an increase of gingival inflammation could be detected in comparison with non-pregnant women.
Evaluation of a pneumatic Martian soil sampler concept
NASA Technical Reports Server (NTRS)
Schaefer, John L.; Neathery, James K.; Stencel, John M.
1994-01-01
The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.
Canpolat, Murat; Mourant, Judith R.
2003-12-09
Apparatus and method for measuring scatterer size in a dense media with only a single fiber for both light delivery and collection are disclosed. White light is used as a source and oscillations of the detected light intensities are measured as a function of wavelength. The maximum and minimum of the oscillations can be used to determine scatterer size for monodisperse distributions of spheres when the refractive indices are known. In addition several properties of the probe relevant to tissue diagnosis are disclosed including the effects of absorption, a broad distribution of scatterers, and the depth probed.
High speed cross-amplitude modulation in concatenated SOA-EAM-SOA.
Cleary, Ciaran S; Manning, Robert J
2012-06-18
We observe a near-ideal high speed amplitude impulse response in an SOA-EAM-SOA configuration under optimum conditions. Full amplitude recovery times as low as 10 ps with modulation depths of 70% were observed in pump-probe measurements. System behavior could be controlled by the choice of signal wavelength, SOA current biases and EAM reverse bias voltages. Experimental data and impulse response modelling indicated that the slow tail in the gain response of first SOA was negated by a combination of cross-absorption modulation between pump and modulated CW probe, and self-gain modulation of the modulated CW probe in both the EAM and second SOA.
Euser, Tijmen G; Harding, Philip J; Vos, Willem L
2009-07-01
We describe an ultrafast time resolved pump-probe spectroscopy setup aimed at studying the switching of nanophotonic structures. Both femtosecond pump and probe pulses can be independently tuned over broad frequency range between 3850 and 21,050 cm(-1). A broad pump scan range allows a large optical penetration depth, while a broad probe scan range is crucial to study strongly photonic crystals. A new data acquisition method allows for sensitive pump-probe measurements, and corrects for fluctuations in probe intensity and pump stray light. We observe a tenfold improvement of the precision of the setup compared to laser fluctuations, allowing a measurement accuracy of better than DeltaR=0.07% in a 1 s measurement time. Demonstrations of the improved technique are presented for a bulk Si wafer, a three-dimensional Si inverse opal photonic bandgap crystal, and z-scan measurements of the two-photon absorption coefficient of Si, GaAs, and the three-photon absorption coefficient of GaP in the infrared wavelength range.
Janssen, Karmon M; Brand, Timothy C; Cunitz, Bryan W; Wang, Yak-Nam; Simon, Julianna C; Starr, Frank; Liggitt, H Denny; Thiel, Jeff; Sorensen, Mathew D; Harper, Jonathan D; Bailey, Michael R; Dunmire, Barbrina
2017-08-01
In the first-in-human trial of ultrasonic propulsion, subjects passed collections of residual stone fragments repositioned with a C5-2 probe. Here, effectiveness and safety in moving multiple fragments are compared between the C5-2 and a custom (SC-50) probe that produces a longer focal beam and burst duration. Effectiveness was quantified by the number of stones expelled from a calyx phantom consisting of a 30-mm deep, water-filled well in a block of tissue mimicking material. Each probe was positioned below the phantom to move stones against gravity. Single propulsion bursts of 50 ms or 3 s duration were applied to three separate targets: 10 fragments of 2 different sizes (1-2 and 2-3 mm) and a single 4 × 7 mm human stone. Safety studies consisted of porcine kidneys exposed to an extreme dose of 10-minute burst duration, including a 7-day survival study and acute studies with surgically implanted stones. Although successful in the clinical trial, the shorter focal beam and maximum 50 ms burst duration of the C5-2 probe moved stones, but did not expel any stones from the phantom's 30-mm deep calyx. The results were similar with the SC-50 probe under the same 50 ms burst duration. Longer (3 s) bursts available with the SC-50 probe expelled all stones at both 4.5 and 9.5 cm "skin-to-stone" depths with lower probe heating compared to the C5-2. No abnormal behavior, urine chemistry, serum chemistry, or histological findings were observed within the kidney or surrounding tissues for the 10 min burst duration used in the animal studies. A longer focal beam and burst duration improved expulsion of a stone and multiple stone fragments from a phantom over a broad range of clinically relevant penetration depths and did not cause kidney injury in animal studies.
Pose-Invariant Face Recognition via RGB-D Images.
Sang, Gaoli; Li, Jing; Zhao, Qijun
2016-01-01
Three-dimensional (3D) face models can intrinsically handle large pose face recognition problem. In this paper, we propose a novel pose-invariant face recognition method via RGB-D images. By employing depth, our method is able to handle self-occlusion and deformation, both of which are challenging problems in two-dimensional (2D) face recognition. Texture images in the gallery can be rendered to the same view as the probe via depth. Meanwhile, depth is also used for similarity measure via frontalization and symmetric filling. Finally, both texture and depth contribute to the final identity estimation. Experiments on Bosphorus, CurtinFaces, Eurecom, and Kiwi databases demonstrate that the additional depth information has improved the performance of face recognition with large pose variations and under even more challenging conditions.
A new checkerboard panel for testing bacterial markers in periodontal disease.
Dahlén, G; Leonhardt, A
2006-02-01
Various microbiological methods have been used for testing bacterial markers for periodontitis and periodontal disease progression. Most studies have used only a limited number of well recognized bacterial species. The purpose of the present study was to evaluate the association of 13 more recently identified bacterial species in a new panel in comparison with 12 previously more recognized periodontotopathogens ('old panel') using the 'checkerboard' DNA-DNA hybridization method. Fifty individuals were chosen who showed at least one site with a probing pocket depth of 6 mm or more (disease) and bleeding on probing and at least one site with a probing pocket depth of 3 mm and without bleeding on probing (health). One diseased and one healthy site on each individual were sampled with the paperpoint technique and the samples were processed in the checkerboard technique against deoxigenin-labeled whole genomic probes to 25 subgingival species representing 12 well recognized and 13 newly identified periodontitis associated species. Twenty-four (out of 25) species were detected more frequently in the subgingival plaque of diseased than healthy sites both at score 1 (> 10(4)) and score 3 (> 10(5)). A significant difference at the higher score (score 3) was noticed for all species of the old panel except for three (Streptococcus intermedius, Selenomonas noxia, and Eikenella corrodens). Of the species in the new panel only Prevotella tannerae, Filifactor alocis, and Porphyromonas endodontalis showed a statistical significant difference between diseased and healthy sites. It was concluded that P. tannerae, F. alocis, and P. endodontalis should be added to the 12 species used for routine diagnostics of periodontitis-associated bacterial flora.
Loginova, D B; Silkova, O G
2014-08-01
The regulation of chromosomal behavior in meiosis in partly fertile wheat-rye amphihaploids was studied using the centromere specific probes pAWRC1 and Ae. tauschii pAet6-09. Comparative analysis of the probe localization patterns in mitosis, normal meiosis in wheat Triticum aestivum L. and rye Secale cereale L., and meiosis in amphihaploids was performed. The differences in the structure of centromeres in monopolar- and bipolar- oriented chromosomes were revealed. Single dense hybridization signals were observed in the diplotene and the metaphase of the first meiotic division, while hybridization signals appeared as stretched bands with diffuse structure located across the centromere region in mitosis and the second round of meiotic division. Based upon the obtained data, we used the corresponding centromere-specific probes as a tool for the analysis of chromosomal behavior in meiosis in amphihaploids. In meiocytes with three types of chromosome behavior (reductional, equational plus reductional, and equational), dense point-like hybridization signals for the pAet6-09 probe were observed for univalents with the reductional division type and stretched bands with diffuse structure for those with the equational division type. Thus, pAet6-09 probe localization patterns suggest some structural and functional specificities of centromeres in the meiosis in wheat-rye amphihaploids that reflect special regulation of chromosomal behavior during equational division. Meiocytes with true mitotic division were also observed in anthers predominantly containing meiocytes with chromosomes undergoing equational division.
NASA Astrophysics Data System (ADS)
Howard-Jones, M. H.; Ballard, V. D.; Allen, A. E.; Frischer, M. E.; Verity, P. G.
2002-12-01
The purpose of this study was to determine bacterioplankton abundance and activity in the Barents Sea using the novel modified vital stain and probe (mVSP) method. The mVSP is a protocol that combines DAPI and propidium iodide staining with 16S rRNA eubacterial-specific oligonucleotide probes to determine the physiological status of individual microbial cells. Bacterial abundance and metabolic activity were measured in near-surface waters and with depth at stations in the central Barents Sea during a cruise in June/July 1999. Viral abundance was also determined for 19 transect stations and at depth (2-200 m) for five intensive 24-h stations. In general, bacterial and viral abundances varied across the transect, but showed peaks of abundance (6×10 9 cells l -1, 9×10 9 viruses l -1) in Polar Front water masses. Viruses were abundant in seawater and exceeded bacterial abundance. Metabolic activity was determined for individual cells using 16S rRNA eubacterial-specific oligonucleotide probes, and for the total community with 3H-leucine incorporation. Activity measured by oligonucleotide probes increased from south to north. The fraction of cells that were active was lowest in the southern Barents Sea (20%) and highest in the Polar Front (53%). The proportion of cells at the 24-h stations that were determined to be active decreased with depth, but not with distance from ice cover. Leucine incorporation rates varied significantly and did not always correlate with probe measurements. The proportion of total cells that had compromised membranes and were therefore considered dead remained relatively constant (<10%) across the transect. The percent of dead cells in the near surface waters and at depth were statistically similar. The percent dead cells made up only a small fraction of the total population at the 24-h stations. The largest and most variable fraction of cells were those classified as low activity (25-80%), which supports the hypothesis that a significant fraction of cells in aquatic ecosystems are inactive. Bacterioplankton production rates ranged from <0.05 to 2.8 mg C m -3 day -1. Growth rates ranged from <0.05 to 0.25 day -1, implying turnover rates of 2.5 to >200 days. Our results demonstrate that bacterioplankton and viruses are dynamic but ubiquitous features of Arctic microbial communities. The contribution of bacteria and viruses to Arctic food webs is discussed.
Identifying the predominant chemical reductants and pathways for electron transfer in anaerobic systems is paramount to the development of environmental fate models that incorporate pathways for abiotic reductive transformations. Currently, such models do not exist. In this chapt...
Sağlam, Mehmet; Arslan, Uğur; Buket Bozkurt, Şerife; Hakki, Sema S
2013-09-01
The purpose of this single-masked, randomized, controlled clinical trial was to evaluate the effects of boric acid irrigation as an adjunct to scaling and root planing (SRP) on clinical and microbiologic parameters and compare this method with chlorhexidine irrigation and SRP alone in patients with chronic periodontitis (CP). Forty-five systemically healthy patients with CP are included in this study. They were divided into three groups: 1) SRP + saline irrigation (C); 2) SRP + chlorhexidine irrigation (CHX); and 3) SRP + boric acid irrigation (B). To determine an ideal concentration of boric acid, a preclinical analysis was conducted. At baseline, 1 month, and 3 months after treatment, clinical measurements, including plaque index (PI), gingival index (GI), probing depth (PD), clinical attachment level (CAL), and bleeding on probing (BOP), were performed, and subgingival plaque samples were taken. Quantitative analysis of Porphyromonas gingivalis (Pg), Tannerella forsythia (Tf), and Treponema denticola (Td) was performed using real-time polymerase chain reaction (PCR) procedures. The concentration of boric acid is 0.75% in this study. All clinical parameters showed statistically significant reduction at all time points compared to baseline in all groups (P <0.001). Whole-mouth PD and CAL reduction was similar in all groups at all time points after treatment (P >0.05). The PD and CAL reductions for moderately deep pockets (PD ≥5 and <7) were greater in the B group compared to other groups between baseline and 1 month (P <0.05). For deep pockets (PD ≥7), reductions were similar in the B and CHX groups (P >0.05). BOP (percentage) was significantly lower in the B group compared with the CHX and C groups in the first month after treatment (P <0.001). GI and PI scores were significantly lower in the B and CHX groups compared with the C group at all time points after treatment (P <0.05). The amounts of Pg, Tf, and Td were significantly reduced in all treatment groups after 1 month (P <0.05). No statistically significant differences were detected among the groups for microbiologic parameters at any time points after treatment (P >0.05). The results of this study suggest that boric acid could be an alternative to chlorhexidine, and it might be more favorable because boric acid was superior in whole-mouth BOP as well as PD and CAL reduction for moderate pockets in early time periods.
Direct depth distribution measurement of deuterium in bulk tungsten exposed to high-flux plasma
Taylor, Chase N.; Shimada, M.
2017-05-08
Understanding tritium retention and permeation in plasma-facing components is critical for fusion safety and fuel cycle control. Glow discharge optical emission spectroscopy (GD-OES) is shown to be an effective tool to reveal the depth profile of deuterium in tungsten. Results confirm the detection of deuterium. Furthermore, a ~46 µm depth profile revealed that the deuterium content decreased precipitously in the first 7 µm, and detectable amounts were observed to depths in excess of 20 µm. The large probing depth of GD-OES (up to 100s of µm) enables studies not previously accessible to the more conventional techniques for investigating deuterium retention.more » Of particular applicability is the use of GD-OES to measure the depth profile for experiments where high diffusion is expected: deuterium retention in neutron irradiated materials, and ultra-high deuterium fluences in burning plasma environment.« less
Direct depth distribution measurement of deuterium in bulk tungsten exposed to high-flux plasma
NASA Astrophysics Data System (ADS)
Taylor, C. N.; Shimada, M.
2017-05-01
Understanding tritium retention and permeation in plasma-facing components is critical for fusion safety and fuel cycle control. Glow discharge optical emission spectroscopy (GD-OES) is shown to be an effective tool to reveal the depth profile of deuterium in tungsten. Results confirm the detection of deuterium. A ˜46 μm depth profile revealed that the deuterium content decreased precipitously in the first 7 μm, and detectable amounts were observed to depths in excess of 20 μm. The large probing depth of GD-OES (up to 100s of μm) enables studies not previously accessible to the more conventional techniques for investigating deuterium retention. Of particular applicability is the use of GD-OES to measure the depth profile for experiments where high deuterium concentration in the bulk material is expected: deuterium retention in neutron irradiated materials, and ultra-high deuterium fluences in burning plasma environment.
Influence of metallic surface states on electron affinity of epitaxial AlN films
NASA Astrophysics Data System (ADS)
Mishra, Monu; Krishna, Shibin; Aggarwal, Neha; Gupta, Govind
2017-06-01
The present article investigates surface metallic states induced alteration in the electron affinity of epitaxial AlN films. AlN films grown by plasma-assisted molecular beam epitaxy system with (30% and 16%) and without metallic aluminium on the surface were probed via photoemission spectroscopic measurements. An in-depth analysis exploring the influence of metallic aluminium and native oxide on the electronic structure of the films is performed. It was observed that the metallic states pinned the Fermi Level (FL) near valence band edge and lead to the reduction of electron affinity (EA). These metallic states initiated charge transfer and induced changes in surface and interface dipoles strength. Therefore, the EA of the films varied between 0.6-1.0 eV due to the variation in contribution of metallic states and native oxide. However, the surface barrier height (SBH) increased (4.2-3.5 eV) adversely due to the availability of donor-like surface states in metallic aluminium rich films.
Slow-muon study of quaternary solar-cell materials: Single layers and p -n junctions
NASA Astrophysics Data System (ADS)
Alberto, H. V.; Vilão, R. C.; Vieira, R. B. L.; Gil, J. M.; Weidinger, A.; Sousa, M. G.; Teixeira, J. P.; da Cunha, A. F.; Leitão, J. P.; Salomé, P. M. P.; Fernandes, P. A.; Törndahl, T.; Prokscha, T.; Suter, A.; Salman, Z.
2018-02-01
Thin films and p -n junctions for solar cells based on the absorber materials Cu (In ,G a ) Se2 and Cu2ZnSnS4 were investigated as a function of depth using implanted low energy muons. The most significant result is a clear decrease of the formation probability of the Mu+ state at the heterojunction interface as well as at the surface of the Cu (In ,G a ) Se2 film. This reduction is attributed to a reduced bonding reaction of the muon in the absorber defect layer at its surface. In addition, the activation energies for the conversion from a muon in an atomiclike configuration to a anion-bound position are determined from temperature-dependence measurements. It is concluded that the muon probe provides a measurement of the effective surface defect layer width, both at the heterojunctions and at the films. The CIGS surface defect layer is crucial for solar-cell electrical performance and additional information can be used for further optimizations of the surface.
NASA Astrophysics Data System (ADS)
Marinho, Kelly C. T.; Giovani, Elcio M.
2016-03-01
This study was to evaluate clinical and microbiological effectiveness of photodynamic therapy (PDT) in the treatment of periodontal disease in kidney-transplanted patients. Eight kidney transplanted patients treated at Paulista University were arranged in two groups: SRP performed scaling and root planning by ultrasound; SRP+PDT- in the same patient, which was held to PDT in the opposite quadrant, with 0.01% methylene blue and red laser gallium aluminum arsenide, wavelength 660 nm, power 100 mW. There was reduction in probing pocket depth after 45 days and 3 months regardless the group examined; plaque and bleeding index showed improvement over time, regardless the technique used, and bleeding index in the SRP+PDT group was lower when compared with the baseline the other times. There was no difference in the frequency of pathogens. Photodynamic therapy may be an option for treatment of periodontal disease in renal-transplanted patients and its effectiveness is similar to conventional therapy.
Yazdi, Farin Kiany; Karimi, Noozhan; Rasouli, Manoochehr; Roozbeh, Jamshid
2013-01-01
C-reactive protein (CRP) has been implicated as a possible mediator of the association between periodontitis and several systemic diseases. This study evaluated the impact of nonsurgical periodontal treatment on the serum levels of CRP in chronic kidney disease (CKD) patients on hemodialysis. A total of 77 CKD patients on hemodialysis were included in this study. At baseline, periodontal examination was assessed for all the patients, and chronic periodontitis was defined through clinical attachment level and probing pocket depth, according to the American Association of Periodontology. Nonsurgical periodontal treatment was performed and serum levels of CRP were evaluated at baseline and 8 weeks after periodontal treatment. Periodontal treatment resulted in significant reductions in CRP levels (p < 0.001). The difference between pre- and posttreatment CRP concentrations did not show any significant relationship with the severity of periodontitis. Periodontitis is an important source of systemic inflammation in CKD patients. Nonsurgical periodontal treatment can effectively reduce the serum level of CRP in these patients.
Quenching methods for background reduction in luminescence-based probe-target binding assays
Cai, Hong [Los Alamos, NM; Goodwin, Peter M [Los Alamos, NM; Keller, Richard A [Los Alamos, NM; Nolan, Rhiannon L [Santa Fe, NM
2007-04-10
Background luminescence is reduced from a solution containing unbound luminescent probes, each having a first molecule that attaches to a target molecule and having an attached luminescent moiety, and luminescent probe/target adducts. Quenching capture reagent molecules are formed that are capable of forming an adduct with the unbound luminescent probes and having an attached quencher material effective to quench luminescence of the luminescent moiety. The quencher material of the capture reagent molecules is added to a solution of the luminescent probe/target adducts and binds in a proximity to the luminescent moiety of the unbound luminescent probes to quench luminescence from the luminescent moiety when the luminescent moiety is exposed to exciting illumination. The quencher capture reagent does not bind to probe molecules that are bound to target molecules and the probe/target adduct emission is not quenched.
NASA Astrophysics Data System (ADS)
Xie, Yijing; Bonin, Tim; Löffler, Susanne; Hüttmann, Gereon; Tronnier, Volker; Hofmann, Ulrich G.
2013-02-01
A well-established navigation method is one of the key conditions for successful brain surgery: it should be accurate, safe and online operable. Recent research shows that optical coherence tomography (OCT) is a potential solution for this application by providing a high resolution and small probe dimension. In this study a fiber-based spectral-domain OCT system utilizing a super-luminescent-diode with the center wavelength of 840 nm providing 14.5 μm axial resolution was used. A composite 125 μm diameter detecting probe with a gradient index (GRIN) fiber fused to a single mode fiber was employed. Signals were reconstructed into grayscale images by horizontally aligning A-scans from the same trajectory with different depths. The reconstructed images can display brain morphology along the entire trajectory. For scans of typical white matter, the signals showed a higher reflection of light intensity with lower penetration depth as well as a steeper attenuation rate compared to the scans typical for gray matter. Micro-structures such as axon bundles (70 μm) in the caudate nucleus are visible in the reconstructed images. This study explores the potential of OCT to be a navigation modality in brain surgery.
Restoration of the Apollo Heat Flow Experiments Metadata
NASA Technical Reports Server (NTRS)
Nagihara, S.; Stephens, M. K.; Taylor, P. T.; Williams, D. R.; Hills, H. K.; Nakamura, Y.
2015-01-01
Geothermal heat flow probes were deployed on the Apollo 15 and 17 missions as part of the Apollo Lunar Surface Experiments Package (ALSEP). At each landing site, the astronauts drilled 2 holes, 10-m apart, and installed a probe in each. The holes were 1- and 1.5-m deep at the Apollo 15 site and 2.5-m deep at the Apollo 17 sites. The probes monitored surface temperature and subsurface temperatures at different depths. At the Apollo 15 site, the monitoring continued from July 1971 to January 1977. At the Apollo 17 site, it did from December 1972 to September 1977. Based on the observations made through December 1974, Marcus Langseth, the principal investigator of the heat flow experiments (HFE), determined the thermal conductivity of the lunar regolith by mathematically modeling how the seasonal temperature fluctuation propagated down through the regolith. He also determined the temperature unaffected by diurnal and seasonal thermal waves of the regolith at different depths, which yielded the geothermal gradient. By multiplying the thermal gradient and the thermal conductivity, Langseth obtained the endogenic heat flow of the Moon as 21 mW/m(exp 2) at Site 15 and 16 mW/m(exp 2) at Site 17.
Study of clutter origin in in-vivo epi-optoacoustic imaging of human forearms
NASA Astrophysics Data System (ADS)
Preisser, Stefan; Held, Gerrit; Akarçay, Hidayet G.; Jaeger, Michael; Frenz, Martin
2016-09-01
Epi-optoacoustic (OA) imaging offers flexible clinical diagnostics of the human body when the irradiation optic is attached to or directly integrated into the acoustic probe. Epi-OA images, however, encounter clutter that deteriorates contrast and significantly limits imaging depth. This study elaborates clutter origin in clinical epi-optoacoustic imaging using a linear array probe for scanning the human forearm. We demonstrate that the clutter strength strongly varies with the imaging location but stays stable over time, indicating that clutter is caused by anatomical structures. OA transients which are generated by strong optical absorbers located at the irradiation spot were identified to be the main source of clutter. These transients obscure deep in-plane OA signals when detected by the transducer either directly or after being acoustically scattered in the imaging plane. In addition, OA transients generated in the skin below the probe result in acoustic reverberations, which cause problems in image interpretation and limit imaging depth. Understanding clutter origin allows a better interpretation of clinical OA imaging, helps to design clutter compensation techniques and raises the prospect of contrast optimization via the design of the irradiation geometry.
2014-08-01
and in (b) a standard animal model of prostate cancer. In the preliminary in-vitro study , imaging resolution, contrast to tissue ratio, and lesion...detectability will be assessed relative to a Siemens EV- 8C4 transrectal ultrasound probe. In the in-vivo study , molecular imaging and microvascular...lesions will be imaged at several axial depths using our prototype array and the Siemens EV-8C4 clinical TRUS probe. A blinded reader study will be
Using electron irradiation to probe iron-based superconductors
NASA Astrophysics Data System (ADS)
Cho, Kyuil; Kończykowski, M.; Teknowijoyo, S.; Tanatar, M. A.; Prozorov, R.
2018-06-01
High-energy electron irradiation at low temperatures is an efficient and controlled way to create vacancy–interstitial Frenkel pairs in a crystal lattice, thereby inducing nonmagnetic point-like scattering centers. In combination with London penetration depth and resistivity measurements, the electron irradiation was used as a phase-sensitive probe to study the superconducting order parameter in iron-based superconductors (FeSCs), lending strong support to sign-changing s ± pairing. Here, we review the key results of the effect of electron irradiation in FeSCs.
Kubo, Kyoko; Lloyd, Karen G; F Biddle, Jennifer; Amann, Rudolf; Teske, Andreas; Knittel, Katrin
2012-01-01
Members of the highly diverse Miscellaneous Crenarchaeotal Group (MCG) are globally distributed in various marine and continental habitats. In this study, we applied a polyphasic approach (rRNA slot blot hybridization, quantitative PCR (qPCR) and catalyzed reporter deposition FISH) using newly developed probes and primers for the in situ detection and quantification of MCG crenarchaeota in diverse types of marine sediments and microbial mats. In general, abundance of MCG (cocci, 0.4 μm) relative to other archaea was highest (12–100%) in anoxic, low-energy environments characterized by deeper sulfate depletion and lower microbial respiration rates (P=0.06 for slot blot and P=0.05 for qPCR). When studied in high depth resolution in the White Oak River estuary and Hydrate Ridge methane seeps, changes in MCG abundance relative to total archaea and MCG phylogenetic composition did not correlate with changes in sulfate reduction or methane oxidation with depth. In addition, MCG abundance did not vary significantly (P>0.1) between seep sites (with high rates of methanotrophy) and non-seep sites (with low rates of methanotrophy). This suggests that MCG are likely not methanotrophs. MCG crenarchaeota are highly diverse and contain 17 subgroups, with a range of intragroup similarity of 82 to 94%. This high diversity and widespread distribution in subsurface sediments indicates that this group is globally important in sedimentary processes. PMID:22551871
Differential Measurement Periodontal Structures Mapping System
NASA Technical Reports Server (NTRS)
Companion, John A. (Inventor)
1998-01-01
This invention relates to a periodontal structure mapping system employing a dental handpiece containing first and second acoustic sensors for locating the Cemento-Enamel Junction (CEJ) and measuring the differential depth between the CEJ and the bottom of the periodontal pocket. Measurements are taken at multiple locations on each tooth of a patient, observed, analyzed by an optical analysis subsystem, and archived by a data storage system for subsequent study and comparison with previous and subsequent measurements. Ultrasonic transducers for the first and second acoustic sensors are contained within the handpiece and in connection with a control computer. Pressurized water is provided for the depth measurement sensor and a linearly movable probe sensor serves as the sensor for the CEJ finder. The linear movement of the CEJ sensor is obtained by a control computer actuated by the prober. In an alternate embodiment, the CEJ probe is an optical fiber sensor with appropriate analysis structure provided therefor.
Markou, Nikolaos; Pepelassi, Eudoxie; Kotsovilis, Sotirios; Vrotsos, Ioannis; Vavouraki, Helen; Stamatakis, Harry Charalabos
2010-08-01
On the basis of systematic reviews and randomized controlled trials, the authors provide reports of two cases in which platelet-rich plasma (PRP) combined with demineralized freeze-dried bone allograft (DFDBA) was used to treat periodontal endosseous defects. Clinicians treated two circumferential endosseous defects with a probing pocket depth of 5 and 8 millimeters, respectively (case 1), and a combined 1-2-3-wall endosseous defect with a probing pocket depth of 6 mm (case 2) by using the combination of PRP and DFDBA. At six months, complete periodontal pocket resolution occurred in all defects, and clinical attachment level and radiographic defect fill in all defects exhibited significant improvement compared with presurgical values. The combination of PRP and DFDBA may be clinically and radiographically efficacious in the treatment of periodontal endosseous defects.
Wang, Peng; Behan, Gavin; Kirkland, Angus I; Nellist, Peter D; Cosgriff, Eireann C; D'Alfonso, Adrian J; Morgan, Andrew J; Allen, Leslie J; Hashimoto, Ayako; Takeguchi, Masaki; Mitsuishi, Kazutaka; Shimojo, Masayuki
2011-06-01
Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored. Copyright © 2010 Elsevier B.V. All rights reserved.
Ju, Bing-Feng; Chen, Yuan-Liu; Zhang, Wei; Zhu, Wule; Jin, Chao; Fang, F Z
2012-05-01
A compact but practical scanning tunneling microscope (STM) with high aspect ratio and high depth capability has been specially developed. Long range scanning mechanism with tilt-adjustment stage is adopted for the purpose of adjusting the probe-sample relative angle to compensate the non-parallel effects. A periodical trench microstructure with a pitch of 10 μm has been successfully imaged with a long scanning range up to 2.0 mm. More innovatively, a deep trench with depth and step height of 23.0 μm has also been successfully measured, and slope angle of the sidewall can approximately achieve 67°. The probe can continuously climb the high step and exploring the trench bottom without tip crashing. The new STM could perform long range measurement for the deep trench and high step surfaces without image distortion. It enables accurate measurement and quality control of periodical trench microstructures.
Cling film as a barrier against CJD in corneal contact A-scan ultrasonography.
Rani, Asha; Dunne, Mark C M; Barnes, Derek A
2003-01-01
To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another.
Grover, Ginni; DeLuca, Keith; Quirin, Sean; DeLuca, Jennifer; Piestun, Rafael
2012-01-01
Super-resolution imaging with photo-activatable or photo-switchable probes is a promising tool in biological applications to reveal previously unresolved intra-cellular details with visible light. This field benefits from developments in the areas of molecular probes, optical systems, and computational post-processing of the data. The joint design of optics and reconstruction processes using double-helix point spread functions (DH-PSF) provides high resolution three-dimensional (3D) imaging over a long depth-of-field. We demonstrate for the first time a method integrating a Fisher information efficient DH-PSF design, a surface relief optical phase mask, and an optimal 3D localization estimator. 3D super-resolution imaging using photo-switchable dyes reveals the 3D microtubule network in mammalian cells with localization precision approaching the information theoretical limit over a depth of 1.2 µm. PMID:23187521
van Manen's method and reduction in a phenomenological hermeneutic study.
Heinonen, Kristiina
2015-03-01
To describe van Manen's method and concept of reduction in a study that used a phenomenological hermeneutic approach. Nurse researchers have used van Manen's method in different ways. Participants' lifeworlds are described in depth, but descriptions of reduction have been brief. The literature and knowledge review and manual search of research articles. Databases Web Science, PubMed, CINAHL and PsycINFO, without applying a time period, to identify uses of van Manen's method. This paper shows how van Manen's method has been used in nursing research and gives some examples of van Manen's reduction. Reduction enables us to conduct in-depth phenomenological hermeneutic research and understand people's lifeworlds. As there are many variations in adapting reduction, it is complex and confusing. This paper contributes to the discussion of phenomenology, hermeneutic study and reduction. It opens up reduction as a method for researchers to exploit.
Characterization of photoacoustic sources in tissue using time domain measurements
NASA Astrophysics Data System (ADS)
Viator, John Andrew
Photoacoustic phenomenon in tissue and tissue phantoms is investigated with the particular goal of discrimination of diseased and healthy tissue. Propagation of broadband photoacoustic sources in tissue phantoms is studied with emphasis on attenuation, dispersion, and diffraction. Attenuation of photoacoustic waves induced by a circular laser spot on an absorber/air interface is modeled by the on-axis approximation of the acoustic field of a baffled piston source. Dispersion is studied in a diffraction free situation, where the disk of irradiation was created by a 5 mm laser spot on a 200 cm -1 solution. The genesis of diffraction in an absorbing solution was displayed by showing the merging of a boundary wave with a plane wave from a circular laser spot on an absorbing solution. Depth profiling of absorbing tissue phantoms and stained tissue was shown using a photoacoustic method. Acrylamide gels with layers of different optical absorption and stained elastin biomaterials were irradiated with stress confined laser pulses. The resulting acoustic waves were detected with a lithium niobate wideband acoustic transducer and processed in an algorithm to determine absorption coefficient as a function of depth. Spherical photoacoustic sources were generated in optically clear and turbid tissue phantoms. Propagation time and acoustic pulse duration were used to determine location and size, respectively. The photoacoustic sources were imaged using a multiplicative backprojection scheme. Image sources from acoustic boundaries were detected and dipole sources were detected and imaged. Finally an endoscopic photoacoustic probe was designed, built, and tested for use in determining treatment depth after palliative photodynamic therapy of esophageal cancer. The probe was less than 2.5 mm in diameter and consisted of a side firing 600 mum optical fiber to deliver laser energy and a 890 mum diameter, side viewing piezoelectric detector. The sensitivity of the probe was determined. The probe was also tested on coagulated and non-coagulated liver, ex vivo and on normally perfused and underperfused human skin, in vivo.
Size matters: Perceived depth magnitude varies with stimulus height.
Tsirlin, Inna; Wilcox, Laurie M; Allison, Robert S
2016-06-01
Both the upper and lower disparity limits for stereopsis vary with the size of the targets. Recently, Tsirlin, Wilcox, and Allison (2012) suggested that perceived depth magnitude from stereopsis might also depend on the vertical extent of a stimulus. To test this hypothesis we compared apparent depth in small discs to depth in long bars with equivalent width and disparity. We used three estimation techniques: a virtual ruler, a touch-sensor (for haptic estimates) and a disparity probe. We found that depth estimates were significantly larger for the bar stimuli than for the disc stimuli for all methods of estimation and different configurations. In a second experiment, we measured perceived depth as a function of the height of the bar and the radius of the disc. Perceived depth increased with increasing bar height and disc radius suggesting that disparity is integrated along the vertical edges. We discuss size-disparity correlation and inter-neural excitatory connections as potential mechanisms that could account for these results. Copyright © 2016 Elsevier Ltd. All rights reserved.
Connective tissue graft vs. emdogain: A new approach to compare the outcomes.
Sayar, Ferena; Akhundi, Nasrin; Gholami, Sanaz
2013-01-01
The aim of this clinical trial study was to clinically evaluate the use of enamel matrix protein derivative combined with the coronally positioned flap to treat gingival recession compared to the subepithelial connective tissue graft by a new method to obtain denuded root surface area. Thirteen patients, each with two or more similar bilateral Miller class I or II gingival recession (40 recessions) were randomly assigned to the test (enamel matrix protein derivative + coronally positioned flap) or control group (subepithelial connective tissue graft). Recession depth, width, probing depth, keratinized gingival, and plaque index were recorded at baseline and at one, three, and six months after treatment. A stent was used to measure the denuded root surface area at each examination session. Results were analyzed using Kolmogorov-Smirnov, Wilcoxon, Friedman, paired-sample t test. The average percentages of root coverage for control and test groups were 63.3% and 55%, respectively. Both groups showed significant keratinized gingival increase (P < 0.05). Recession depth decreased significantly in both groups. Root surface area was improved significantly from baseline with no significant difference between the two study groups (P > 0.05). The results of Friedman test were significant for clinical indices (P < 0.05), except for probing depth in control group (P = 0.166). Enamel matrix protein derivative showed the same results as subepithelial connective tissue graft with relatively easy procedure to perform and low patient morbidity.
Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi
2016-07-01
This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.
NASA Astrophysics Data System (ADS)
Akter, Masuda; Kader, Md. Abdul; Pierreux, Sofie; Boeckx, Pascal; Kamal, Ahammad Mostafa; Sleutel, Steven
2016-04-01
Water-saving irrigation such as AWD may significantly alter depth profiles of moisture content, pH, Eh and soil microbial activity. Modelling the effect of irrigation management on soil N mineralization, therefore requires detailed insight into depth distribution of these variables and dissolved organic carbon (DOC), and evolution of electron acceptors. We set up a field experiment at Bangladesh Agricultural University from January to May' 2015. The cultivated rice variety (BRRI dhan28) was grown under continuous flooding (CF) and alternate wetting and drying (AWD) management, with 120 kg N ha-1(N120) or without (N0)N fertilizer application. We measured soil mineral N and plant N uptake to evaluate N mineralization. CH4 emissions were monitored with timely gas sample collection and GC-analysis. Soil Eh at four depths and temperature at two depths were monitored continuously by Eh/T°-probes connected to a HYPNOS III data logger (MVH, The Netherlands). Simultaneously, soil solution from three depths were sampled with rhizon samplers to track DOC, Fe and Mn in solution. Over the growing season soil and air temperature increased by 8°C, and soil pH stayed near neutral (6.7 to 7.8). In all depths of AWD and CF, Eh dropped sharply to methanic conditions within 21 days after transplanting (DAT). Low redox-potential continued until 77DAT in all cases, except in the puddle layers under AWD, where redox raised to -200mV during drainage. Fe and Mn in soil solution increased gradually over the growing season, indicating continued reductive dissolution of Fe and Mn (hydro-)oxides. DOC increased continuously as well in all depths. Besides to release of DOC bound to pedogenic oxides upon their reductive dissolution, higher plant and soil microbial activity with increasing soil temperature (till 28°C) through the growing season explains the increasing DOC levels. Increasing methanogenic activity as indicated by the high CH4 emissions at 70-84DAT under both CF and AWD is logically linked. The elevated redox potential in puddle layer depth increments during AWD drainage events, significantly (p<0.01) declined the cumulative CH4 emission by 47% when compared to CF management. Moreover, seasonal CH4 emissions in N-fertilized fields (N120) decreased by 29 and 8% under CF and AWD, respectively relative to the control (N0), possibly due to promotion of methanotrophs, which were N-limited in N0. Mostly, mineral N content in N120 plots of AWD and CF exceeded contents in the N0 fields. Contrary to CH4 emission, irrigation management did not affect evolutions of pH, Fe, Mn and DOC in soil solution. Likewise, soil exchangeable N content evolution was unaffected and followed zero-order kinetics (N120: R2=0.53 to 0.81; N0: R2=0.12 to 0.48). Our results generally indicate that in Northern Bangladesh's Boro season, evolutions in paddy soil solution chemistry and CH4 emission are strongly depending on course soil temperature and only secondarily on irrigation management. Whether temperature steers microbial activity and methanogenesis directly or via concomitant plant activity and exudation is not known. Key words: Redox, CH4, emission, mineralization, Fe, Mn, DOC, water management
Azzeh, Manal M
2008-10-01
Peri-implantitis may occur because of biologic or mechanical factors. It can be treated by a variety of methods. In the present case report, treatment was attempted by regenerative osseous surgery associated with an erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser. A 28-year-old, non-smoking male complained of gum recession around an implant in the area of upper left central incisor. After clinical examination and radiographs, it was found that there was 2 mm recession, a probing depth of 7 mm, mobility grade one, and bone mesially and distally. Regenerative osseous surgery was performed using an Er,Cr:YSGG laser (2,780 nm) at different settings to open the flap, remove the granulation tissues, perforate the bone, and clean the implant surface. A bone graft and a bioabsorbable membrane were used for bone regeneration. The patient was reevaluated at 3, 6, 12 (with reentry), and 18 months postoperatively. At 3, 6, and 12 months postoperatively, there were no reported complications, with probing depths of 3 to 5 mm, <1 mm recession, no bleeding or implant mobility, and good bone formation. Slight pus discharge was present at 12 months. At 18 months postoperatively, probing depth was 2 mm, recession was <1 mm, there was no bleeding, implant mobility, or discharge, and there was better bone formation. The results were satisfactory to the patient and the clinician. The Er,Cr:YSGG laser enabled regenerative osseous surgery around an implant with no complications and with high patient and clinician satisfaction and confidence.
Anitha, V; Nair, Sushma; Shivakumar, V; Shanmugam, M; Priya, B Meena; Rajesh, P
2015-01-01
HsCRP (Highly sensitive C reactive protein) is a global indicator for future vascular events in adults detected in blood stream 48 hours before the cardiovascular event. Periodontal disease may increase blood levels of inflammatory markers like IL-6, CRP and HsCRP. Hence the aim of the present study is to evaluate the presence of elevated HsCRP levels in chronic periodontitis patients. 100 patients who reported for cardiac master health check up were enrolled in the study. The periodontal status was assessed using periodontal probing pocket depth and clinical attachment level. The decayed, missing and filled tooth was recorded using DMFT index. The venous samples of these patients were obtained for recording HsCRP levels. Pearson correlation was used to analyze the relationship between HsCRP level and probing pocket depth, clinical attachment loss and DMFT. The correlation value was 0.051, 0.025 and 0.101 respectively, the correlation is statistically significant for probing pocket depth and clinical attachment level (P>0.05). Chi-square test was performed to study the association between gender and HsCRP, Diabetes Mellitus and HsCRP and Hypertension and HsCRP; the results showed that there is no significant association between any of the above mentioned factors and HsCRP level in blood. We found an increased level of HsCRP in patients with chronic periodontitis which revealed the susceptibility of these patients to cardiac diseases like myocardial infarction and stroke. Hence present day focus in the line of management of cardiac patient has changed from the periodontal perspective.
Simulation of Fluid Flow and Collection Efficiency for an SEA Multi-element Probe
NASA Technical Reports Server (NTRS)
Rigby, David L.; Struk, Peter M.; Bidwell, Colin
2014-01-01
Numerical simulations of fluid flow and collection efficiency for a Science Engineering Associates (SEA) multi-element probe are presented. Simulation of the flow field was produced using the Glenn-HT Navier-Stokes solver. Three dimensional unsteady results were produced and then time averaged for the collection efficiency results. Three grid densities were investigated to enable an assessment of grid dependence. Collection efficiencies were generated for three spherical particle sizes, 100, 20, and 5 micron in diameter, using the codes LEWICE3D and LEWICE2D. The free stream Mach number was 0.27, representing a velocity of approximately 86 ms. It was observed that a reduction in velocity of about 15-20 occurred as the flow entered the shroud of the probe.Collection efficiency results indicate a reduction in collection efficiency as particle size is reduced. The reduction with particle size is expected, however, the results tended to be lower than previous results generated for isolated two-dimensional elements. The deviation from the two-dimensional results is more pronounced for the smaller particles and is likely due to the effect of the protective shroud.
Hierarchical Nafion enhanced carbon aerogels for sensing applications
NASA Astrophysics Data System (ADS)
Weng, Bo; Ding, Ailing; Liu, Yuqing; Diao, Jianglin; Razal, Joselito; Lau, King Tong; Shepherd, Roderick; Li, Changming; Chen, Jun
2016-02-01
This work describes the fabrication of hierarchical 3D Nafion enhanced carbon aerogels (NECAGs) for sensing applications via a fast freeze drying method. Graphene oxide, multiwalled carbon nanotubes and Nafion were mixed and extruded into liquid nitrogen followed by the removal of ice crystals by freeze drying. The addition of Nafion enhanced the mechanical strength of NECAGs and effective control of the cellular morphology and pore size was achieved. The resultant NECAGs demonstrated high strength, low density, and high specific surface area and can achieve a modulus of 20 kPa, an electrical conductivity of 140 S m-1, and a specific capacity of 136.8 F g-1 after reduction. Therefore, NECAG monoliths performed well as a gas sensor and as a biosensor with high sensitivity and selectivity. The remarkable sensitivity of 8.52 × 103 μA mM-1 cm-2 was obtained in dopamine (DA) detection, which is two orders of magnitude better than the literature reported values using graphene aerogel electrodes made from a porous Ni template. These outstanding properties make the NECAG a promising electrode candidate for a wide range of applications. Further in-depth investigations are being undertaken to probe the structure-property relationship of NECAG monoliths prepared under various conditions.This work describes the fabrication of hierarchical 3D Nafion enhanced carbon aerogels (NECAGs) for sensing applications via a fast freeze drying method. Graphene oxide, multiwalled carbon nanotubes and Nafion were mixed and extruded into liquid nitrogen followed by the removal of ice crystals by freeze drying. The addition of Nafion enhanced the mechanical strength of NECAGs and effective control of the cellular morphology and pore size was achieved. The resultant NECAGs demonstrated high strength, low density, and high specific surface area and can achieve a modulus of 20 kPa, an electrical conductivity of 140 S m-1, and a specific capacity of 136.8 F g-1 after reduction. Therefore, NECAG monoliths performed well as a gas sensor and as a biosensor with high sensitivity and selectivity. The remarkable sensitivity of 8.52 × 103 μA mM-1 cm-2 was obtained in dopamine (DA) detection, which is two orders of magnitude better than the literature reported values using graphene aerogel electrodes made from a porous Ni template. These outstanding properties make the NECAG a promising electrode candidate for a wide range of applications. Further in-depth investigations are being undertaken to probe the structure-property relationship of NECAG monoliths prepared under various conditions. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08631k
Antibiotics in aggressive periodontitis, is there a clinical benefit?
Rajendra, Anjana; Spivakovsky, Silvia
2016-12-01
Data sourcesMedline, Embase and CENTRAL databases were searched up to December 2014. Unpublished data were sought by searching a database listing unpublished studies OpenGray [http://www.opengrey.eu/], formerly OpenSIGLE.Study selectionRandomised clinical trials assessing treatment of patients with AgP comparing scaling and root planing (SRP) alone with SRP plus a single antibiotic or a combination of drugs with a minimum of three months follow-up were considered. Studies specifically designed to evaluate smokers or subjects with diabetes mellitus and HIV/AIDS were not included.Data extraction and synthesisTwo researchers independently screened titles, abstracts and full texts of the search results. The studies, which fulfilled inclusion criteria, underwent validity assessment and data extraction using a specifically designed form. The quality of included studies was assessed using the Cochranes collaboration tool for risk of bias. Only two of the 11 included trials were considered at a low risk of bias. The data extracted from ten studies was analysed by pair-wise meta-analyses and the data extracted from five studies was included in Bayesian network meta-analyses pooled estimates. The six studies evaluated in the pairwise meta-analyses were excluded in the pooled estimates because four studies included patients with advanced disease only and one study did not present average data for pocket depth (PD) and clinical attachment level (CAL) and another one for using a different mechanical treatment.ResultsFourteen studies reporting 11 randomised clinical trials with a total of 388 patients were included in the review. Nine of 11 studies reported a statistically significant greater gain in full mouth mean clinical attachment (CA) and reduction in probing depth (PD) when a systemic antibiotic was used. From those studies the calculated mean difference for CA gained was 1.08 mm (p < 0.0001) and for PD reduction was 1.05 mm (p< 0.00001) for SRP + Metronidazole (Mtz). For SRP + Mtz+ amoxicillin (Amx) group the mean difference was 0.45 mm for CA gained and 0.53 mm for PD reduction (p<0.00001) than SRP alone/placebo. Bayesian network meta-analysis showed some additional benefits in CA gain and PD reduction when SRP was associated with systemic antibiotics.ConclusionsThe results support a statistically significant benefit of adjunctive systemic antibiotics in the treatment of AgP. The most consistent advantages - reduction in PD and CAL gain - were attained with the use of Mtz and Mtz + Amx. Future RCTs should be designed in order to directly compare these two antibiotic protocols in the treatment of AgP.
NASA Astrophysics Data System (ADS)
Zhang, N.; Quiring, S. M.; Ochsner, T. E.
2017-12-01
Each soil moisture monitoring network commonly adopts different sensor technologies. This results in different measurement units, depths and impedes large-scale soil moisture applications that seek to integrate data from multiple networks. Therefore, a comprehensive comparison of different sensors to identify the best approach for integrating and homogenizing measurements from different sensors is required. This study compares three commonly used sensors, including Stevens Water Hydra Probes, Campbell Scientific CS616 TDR and CS 229-L heat dissipation sensors based on data from May 2010 to December 2012 from the Marena, Oklahoma, In Situ Sensor Testbed (MOISST). All sensors are installed at common depths of 5, 10, 20, 50, 100 cm. The results reveal that the differences between the three sensors tends to increase with depth. The CDF plots showed CS 229 is most sensitive to moisture variation in dry condition and most easily saturated in wet condition, followed by Hydra probe and CS616. Our results show that calculating percentiles is a good normalization method for standardizing measurements from different sensors. Our preliminary results demonstrate that CDF matching can be used to convert measurements from one sensor to another.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pellin, M. J.; Veryovkin, I. V.; Levine, J.
2010-01-01
There are four generally mutually exclusive requirements that plague many mass spectrometric measurements of trace constituents: (1) the small size (limited by the depth probed) of many interesting materials requires high useful yields to simply detect some trace elements, (2) the low concentrations of interesting elements require efficient discrimination from isobaric interferences, (3) it is often necessary to measure the depth distribution of elements with high surface and low bulk contributions, and (4) many applications require precise isotopic analysis. Resonant ionization mass spectrometry has made dramatic progress in addressing these difficulties over the past five years.
Archer, James; Li, Enbang; Petasecca, Marco; Stevenson, Andrew; Livingstone, Jayde; Dipuglia, Andrew; Davis, Jeremy; Rosenfeld, Anatoly; Lerch, Michael
2018-05-01
Cancer is one of the leading causes of death worldwide. External beam radiation therapy is one of the most important modalities for the treatment of cancers. Synchrotron microbeam radiation therapy (MRT) is a novel pre-clinical therapy that uses highly spatially fractionated X-ray beams to target tumours, allowing doses much higher than conventional radiotherapies to be delivered. A dosimeter with a high spatial resolution is required to provide the appropriate quality assurance for MRT. This work presents a plastic scintillator fibre optic dosimeter with a one-dimensional spatial resolution of 20 µm, an improvement on the dosimeter with a resolution of 50 µm that was demonstrated in previous work. The ability of this probe to resolve microbeams of width 50 µm has been demonstrated. The major limitations of this method were identified, most notably the low-light signal resulting from the small sensitive volume, which made valley dose measurements very challenging. A titanium-based reflective paint was used as a coating on the probe to improve the light collection, but a possible effect of the high-Z material on the probes water-equivalence has been identified. The effect of the reflective paint was a 28.5 ± 4.6% increase in the total light collected; it did not affect the shape of the depth-dose profile, nor did it explain an over-response observed when used to probe at low depths, when compared with an ionization chamber. With improvements to the data acquisition, this probe design has the potential to provide a water-equivalent, inexpensive dosimetry tool for MRT.
The Subsurface Ice Probe (SIPR): A Low-Power Thermal Probe for the Martian Polar Layered Deposits
NASA Technical Reports Server (NTRS)
Cardell, G.; Hecht, M. H.; Carsey, F. D.; Engelhardt, H.; Fisher, D.; Terrell, C.; Thompson, J.
2004-01-01
The distinctive layering visible in images from Mars Global Surveyor of the Martian polar caps, and particularly in the north polar cap, indicates that the stratigraphy of these polar layered deposits may hold a record of Martian climate history covering millions of years. On Earth, ice sheets are cored to retrieve a pristine record of the physical and chemical properties of the ice at depth, and then studied in exacting detail in the laboratory. On the Martian north polar cap, coring is probably not a practical method for implementation in an autonomous lander. As an alternative, thermal probes that drill by melting into the ice are feasible for autonomous operation, and are capable of reasonable approximations to the scientific investigations performed on terrestrial cores, while removing meltwater to the surface for analysis. The Subsurface Ice Probe (SIPR) is such a probe under development at JPL. To explore the dominant climate cycles, it is postulated that tens of meters of depth should be profiled, as this corresponds to the vertical separation of the major layers visible in the MOC images [1]. Optical and spectroscopic analysis of the layers, presumably demarcated by embedded dust and possibly by changes in the ice properties, would contribute to the construction of a chronology. Meltwater analysis may be used to determine the soluble chemistry of the embedded dust, and to monitor gradients of atmospheric gases, particularly hydrogen and oxygen, and isotopic variations that reflect atmospheric conditions at the time the layer was deposited. Thermal measurements can be used to determine the geothermal gradient and the bulk mechanical properties of the ice.
Li, Zhuoyan; Shen, Jin H.; Kozub, John A.; Prasad, Ratna; Lu, Pengcheng; Joos, Karen M.
2014-01-01
Background and Objective Investigations have shown that pulsed lasers tuned to 6.1 μm in wavelength are capable of ablating ocular and neural tissue with minimal collateral damage. This study investigated whether a miniature B-scan forward-imaging optical coherence tomography (OCT) probe can be combined with the laser to provide real-time visual feedback during laser incisions. Study Design/Methods and Materials A miniature 25-gauge B-scan forward-imaging OCT probe was developed and combined with a 250 μm hollow-glass waveguide to permit delivery of 6.1 μm laser energy. A gelatin mixture and both porcine corneal and retinal tissues were simultaneously imaged and lased (6.1 μm, 10 Hz, 0.4-0.7 mJ) through air. The ablation studies were observed and recorded in real time. The crater dimensions were measured using OCT imaging software (Bioptigen, Durham, NC). Histological analysis was performed on the ocular tissues. Results The combined miniature forward-imaging OCT and mid-infrared laser-delivery probe successfully imaged real-time tissue ablation in gelatin, corneal tissue, and retinal tissue. Application of a constant number of 60 pulses at 0.5 mJ/pulse to the gelatin resulted in a mean crater depth of 123 ± 15 μm. For the corneal tissue, there was a significant correlation between the number of pulses used and depth of the lased hole (Pearson correlation coefficient = 0.82; P = 0.0002). Histological analysis of the cornea and retina tissues showed discrete holes with minimal thermal damage. Conclusions A combined miniature OCT and laser -delivery probe can monitor real-time tissue laser ablation. With additional testing and improvements, this novel instrument has the future possibility of effectively guiding surgeries by simultaneously imaging and ablating tissue. PMID:24648326
Efficacy of Connective Tissue with and without Periosteum in Regeneration of Intrabony Defects
Esfahanian, Vahid; Golestaneh, Hedayatollah; Moghaddas, Omid; Ghafari, Mohammad Reza
2014-01-01
Background and aims. Connective tissue grafts with and without periosteum is used in regenerative treatments of bone and has demonstrated successful outcomes in previous investigations. The aim of present study was to evaluate the effectiveness of connective tissue graft with and without periosteum in regeneration of intrabony defects. Materials and methods. In this single-blind randomized split-mouth clinical trial, 15 pairs of intrabony defects in 15 patients with moderate to advanced periodontitis were treated by periosteal connective tissue graft + ABBM (test group) or non-periosteal connective tissue graft + ABBM (control group). Probing pocket depth, clinical attachment level, free gingival margin position, bone crestal position, crest defect depth and defect depth to stent were measured at baseline and after six months by surgical re-entry. Data was analyzed by Student’s t-test and paired t-tests (α=0.05). Results. Changes in clinical parameters after 6 months in the test and control groups were as follows: mean of PPD reduction: 3.1±0.6 (P<0.0001); 2.5±1.0 mm (P<0.0001), CAL gain: 2.3±0.9 (P<0.0001); 2.2±1.0 mm (P<0.0001), bone fill: 2.2±0.7 mm (P<0.0001); 2.2±0.7 mm (P<0.0001), respectively. No significant differences in the position of free gingival margin were observed during 6 months compared to baseline in both groups. Conclusion. Combinations of periosteal connective tissue graft + ABBM and non-periosteal connective tissue graft + ABBM were similarly effective in treating intrabony defects without any favor for any group. Connective tissue and perio-steum can be equally effective in regeneration of intrabony defects. PMID:25587379
John, Cathy Nisha; Stephen, Lawrence Xavier; Joyce Africa, Charlene Wilma
2013-12-03
The immunosuppresion in HIV patients makes them highly susceptible to microbial infections. The aim of the study was to establish whether HIV stage (as depicted by CD4+ T lymphocyte counts) could independently be associated with periodontal status (as revealed by the measurement of clinical indices). One hundred and twenty HIV-infected patients attending an infectious diseases clinic in the Western Cape, South Africa were included in the study. The periodontal clinical indices such as plaque index, gingival index, pocket probing depth and clinical attachment levels were measured on the mesial aspect of the six Ramfjord teeth. The CD4 + T cell counts were taken from the patients' medical records and patients' HIV stage determined and grouped according to their CD4+ T cell counts into A (<200 cells /mm3), B (200-500 cells /mm3) and C (>500 cells /mm3). The mean age of 120 HIV-positive patients was 33.25 years and the mean CD4 + T cell count was 293.43 cells/mm3. The probing depth and clinical attachment loss were found to be significantly associated with the total CD4 + T cell counts but not with HIV stage. Significant correlations were found between age and all clinical indices except for clinical attachment loss. No correlation was found between age and HIV stage of the patients. The use of antiretroviral therapy was significantly associated with probing depth and clinical attachment loss, but not with plaque nor gingival index. Significant associations were observed between smoking and all of the clinical indices except for the gingival index. A significant association was observed between the use of interdental aids and all the clinical indices except for probing depth, while brushing was significantly associated with plaque index only. CD4 + T cell counts were significantly associated with brushing frequency (p = 0.0190) and the use of interdental aids (p = 0.0170). The findings of this study conclude that HIV stage, ART and age are not independent risk factors for changes in the periodontal status of HIV-positive subjects but rather that smoking and oral hygiene habits determine their susceptibility to disease.
Risk factors of chronic periodontitis on healing response: a multilevel modelling analysis.
Song, J; Zhao, H; Pan, C; Li, C; Liu, J; Pan, Y
2017-09-15
Chronic periodontitis is a multifactorial polygenetic disease with an increasing number of associated factors that have been identified over recent decades. Longitudinal epidemiologic studies have demonstrated that the risk factors were related to the progression of the disease. A traditional multivariate regression model was used to find risk factors associated with chronic periodontitis. However, the approach requirement of standard statistical procedures demands individual independence. Multilevel modelling (MLM) data analysis has widely been used in recent years, regarding thorough hierarchical structuring of the data, decomposing the error terms into different levels, and providing a new analytic method and framework for solving this problem. The purpose of our study is to investigate the relationship of clinical periodontal index and the risk factors in chronic periodontitis through MLM analysis and to identify high-risk individuals in the clinical setting. Fifty-four patients with moderate to severe periodontitis were included. They were treated by means of non-surgical periodontal therapy, and then made follow-up visits regularly at 3, 6, and 12 months after therapy. Each patient answered a questionnaire survey and underwent measurement of clinical periodontal parameters. Compared with baseline, probing depth (PD) and clinical attachment loss (CAL) improved significantly after non-surgical periodontal therapy with regular follow-up visits at 3, 6, and 12 months after therapy. The null model and variance component models with no independent variables included were initially obtained to investigate the variance of the PD and CAL reductions across all three levels, and they showed a statistically significant difference (P < 0.001), thus establishing that MLM data analysis was necessary. Site-level had effects on PD and CAL reduction; those variables could explain 77-78% of PD reduction and 70-80% of CAL reduction at 3, 6, and 12 months. Other levels only explain 20-30% of PD and CAL reductions. Site-level had the greatest effect on PD and CAL reduction. Non-surgical periodontal therapy with regular follow-up visits had a remarkable curative effect. All three levels had a substantial influence on the reduction of PD and CAL. Site-level had the largest effect on PD and CAL reductions.
De Genaro Modanese, Danielle; Tiosso-Tamburi, Renato; Furletti de Goes, Vivian Fernandes; de Cássia Bergamaschi, Cristiane; Martinez, Elizabeth Ferreira; Napimoga, Marcelo Henrique; Peruzzo, Daiane Cristina
2016-09-01
This study aims to evaluate the effect of one-stage full-mouth ultrasonic debridement (OSFMUD) on clinical and immunoinflammatory parameters in smokers with generalized aggressive periodontitis (GAgP). Fourteen smoking and 14 non-smoking patients with GAgP were selected. After initial supragingival therapy, patients were treated by OSFMUD. Full-mouth parameters evaluated were: 1) plaque index (PI); 2) bleeding scores (BS); 3) probing depth (PD); and 4) clinical attachment level (CAL). Clinical evaluation was performed, and gingival crevicular fluid (GCF) was collected for selected sites (ss) at baseline and 1, 3, and 6 months. GCF was analyzed via enzyme-linked immunosorbent assay for: 1) receptor activator of nuclear factor-κ B ligand (RANKL); 2) osteoprotegerin (OPG); 3) interleukin (IL)-6; and 4) tumor necrosis factor (TNF)-α, whereas secreted osteoclastogenic factor of activated T-cells (SOFAT) was evaluated by Western blotting. Significant reduction (P <0.05) was observed between baseline and 6 months for: 1) PI; 2) BS; and 3) PD, with no difference between smoking and non-smoking patients (P >0.05). Regarding CAL, only non-smoking patients showed a significant decrease (P <0.05). Significant reduction (P <0.05) was observed in both groups for: 1) PIss; 2) PDss; 3) bleeding on probing; and 4) relative CAL. Smoking and non-smoking patients presented significantly decreased levels of IL-6 and TNF-α over time (P <0.05); however, no difference was observed between groups (P >0.05). RANKL was significantly different (P <0.05) only for non-smokers at 6 months, whereas OPG was not significant (P >0.05). SOFAT expression was significantly lower (P <0.05) after OSFMUD for non-smokers only. Considering the clinical and immunoinflammatory parameters evaluated in this short-term follow-up study, it can be concluded that OSFMUD can be used as an alternative treatment for smokers with GAgP.
NASA Astrophysics Data System (ADS)
Yee, Albert F.
1997-03-01
The relaxational, mechanical and transport properties of glassy polymers are strongly influenced by the nanostructural and dynamical characteristics of each material. In very thin polymer films such characteristics may be affected by the presence of a free surface or a substrate. Positron Annihilation Lifetime Spectroscopy (PALS) is a useful and in some ways unique tool for probing these important characteristics. Conventional PALS on several bulk polymers over an extended temperature range are used to illustrate how these characteristics are obtained(HA Hristov, B Bolan, AF Yee, L Xie, and DW Gidley, accepted by Macromolecules.). A new technique, which we shall call "beam-PALS", and the results of its application on nm-thick polystyrene films supported on one side by a Si substrate are described. In beam-PALS the lifetime, τ _3, and formation fraction, I_3, of triplet positronium decaying in the void volume near the polymer surface are measured versus the positron implantation energy, E. The strong E dependence of I3 supports a spur-electron capture model of Ps formation with deduced spur sizes ranging from 200 to 660 ÅThin film measurements indicate that the mean probe depth can be much smaller, given mainly by the average positron implantation distance, Z(E)(L Xie, GB DeMaggio, WE Frieze, J DeVries, DW Gidley, HA Hristov and AF Yee, PRL 74, 4947 (1995).). The thermal expansion behaviors of thin, Si-supported polystyrene films near the glass transition temperature, Tg were also measured. A reduction in void volume expansion is correlated with a reduction in the apparent Tg as film thickness decreases. Our results can be fitted using a 3-layer model incorporating a 50 Åconstrained layer at the Si interface and a 20 Åsurface region with reduced T_g(GB DeMaggio, WE Frieze, DW Gidley, M Zhu, HA Hristov, and AF Yee, accepted by PRL.).
Kondo, Keiko; Ishikado, Atsushi; Morino, Katsutaro; Nishio, Yoshihiko; Ugi, Satoshi; Kajiwara, Sadae; Kurihara, Mika; Iwakawa, Hiromi; Nakao, Keiko; Uesaki, Syoko; Shigeta, Yasutami; Imanaka, Hiromichi; Yoshizaki, Takeshi; Sekine, Osamu; Makino, Taketoshi; Maegawa, Hiroshi; King, George L; Kashiwagi, Atsunori
2014-06-01
Periodontal disease is related to aging, smoking habits, diabetes mellitus, and systemic inflammation. However, there remains limited evidence about causality from intervention studies. An effective diet for prevention of periodontal disease has not been well established. The current study was an intervention study examining the effects of a high-fiber, low-fat diet on periodontal disease markers in high-risk subjects. Forty-seven volunteers were interviewed for recruitment into the study. Twenty-one volunteers with a body mass index of at least 25.0 kg/m(2) or with impaired glucose tolerance were enrolled in the study. After a 2- to 3-week run-in period, subjects were provided with a test meal consisting of high fiber and low fat (30 kcal/kg of ideal body weight) 3 times a day for 8 weeks and followed by a regular diet for 24 weeks. Four hundred twenty-five teeth from 17 subjects were analyzed. Periodontal disease markers assessed as probing depth (2.28 vs 2.21 vs 2.13 mm; P < .0001), clinical attachment loss (6.11 vs 6.06 vs 5.98 mm; P < .0001), and bleeding on probing (16.2 vs 13.2 vs 14.6 %; P = .005) showed significant reductions after the test-meal period, and these improvements persisted until the follow-up period. Body weight (P < .0001), HbA1c (P < .0001), and high-sensitivity C-reactive protein (P = .038) levels showed improvement after the test-meal period; they returned to baseline levels after the follow-up period. In conclusion, treatment with a high-fiber, low-fat diet for 8 weeks effectively improved periodontal disease markers as well as metabolic profiles, at least in part, by effects other than the reduction of total energy intake. Copyright © 2014 Elsevier Inc. All rights reserved.
Pei, Xi Yan; He, Lu; Ouyang, Xiang Ying
To propose a novel, three-level (severe, moderate, mild) case definition using probing depth (PD), clinical attachment loss (CAL) and bleeding on probing (BOP) for epidemiologic studies on periodontitis. Case definitions (DEF) 1-30 with PD, CAL and BOP were made. Based on data from epidemiologic research in Chengde (Hebei Province, China) in 1992, prevalence of periodontitis by DEF1-30 was calculated and compared with a reference (definitions by Centers for Disease Control and Prevention/American Academy of Periodontology in 2012). Sensitivity, specificity, Youden Index, Cohen's kappa coefficient (CKC) and the area under the receiver operator characteristic curve (AUC) were calculated for the definitions selected. DEF1 and DEF18 for periodontitis, DEF2, DEF3, DEF19 for moderate and severe periodontitis, and DEF5, DEF13, DEF14, DEF21 and DEF25 for severe periodontitis, which were similar for estimation of periodontitis prevalence compared with the reference, were selected. DEF18 for periodontitis, DEF19 for moderate and severe periodontitis, and DEF5 for severe periodontitis were selected because they showed higher values for the Youden Index, CKC and AUC, and formed a three-level definition. A novel three-level case classification of periodontitis using three parameters of PD, CAL and BOP was proposed. The estimated periodontitis prevalence according to the novel proposed definition is close to the prevalence according to the CDC/AAP definition.
Sources of Variability in the Detection of B-Lines, Using Lung Ultrasound.
Pivetta, Emanuele; Baldassa, Federico; Masellis, Serena; Bovaro, Federica; Lupia, Enrico; Maule, Milena M
2018-06-01
Lung ultrasound (LUS) is a largely employed diagnostic tool but an operational protocol for implementation has never been proposed. The lack of standardization clearly introduces variability in LUS results. We enrolled adult patients presenting for acute dyspnea with a clinical suspect of etiology related to heart failure. We calculated agreement among four providers in assessing B-lines. We varied probes, depth, evaluation time and scanning areas and we estimated the importance of each factors on B-lines assessment. Overall agreement among raters varied from a kappa of 0.70 to 0.81. The mean number of B-lines was 5.44 (95% confidence interval, CI, 4.1-6.8). This estimate did not suffer variation by the depth used (0.03, 95% CI -0.2-0.2, more B-lines, using 19 cm versus 10 cm). The use of a convex probe and expertise in LUS reduced the number of artifacts by 1.7 (95% CI 1.5-1.9) and 1.1 in comparison with a phased array probe and naive operators. Evaluation time increased estimates by 1.2 (95% CI 1-1.5) and 2.9 (95% CI 2.7-3.9) B-lines for 4" and 7" clips (reference was 2" clips). This study suggests that the probe, the evaluation time and the level of expertise might affect the results of quantitative assessment of B-lines. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Pavlatou, Anthodesmi; Tsami, Alexandra; Vlahos, Nicolaos; Mantzavinos, Themis; Vrotsos, Ioannis
2013-04-01
To study whether in vitrofertilization (IVF) treatment has any effect on women's preexisting periodontal status and, if pre-existing women's periodontal status has any impact on IVF outcomes, such as superovulation for multiple follicles maturation, oocyte retrieval and embryo transfer, as well as on pregnancy and its outcomes. Sixty women aged 29 to 41 years were recruited in the study. Gingival inflammation (simplified gingival index, GI-S), plaque levels (plaque control record index, PCR), bleeding on probing (BOP) and probing depth (PD), were recorded for all participants before and after IVF. Blood tests were performed prior to IVF. A statistically significant increase in GI-S after IVF was observed in all women (31.9 +/- 18.7% to 61.7 +/- 23.5%), and was higher in women with gingivitis (37.1 +/- 5.7% to 77.6 +/- 6.7%). Women with periodontitis demonstrated a statistically significant increase in BOP (67.7 +/- 6.6% to 89.5 +/- 7.1%), and in the sum of probing pocket depths (from 243.8 +/- 56.2 mm to 250.5 +/- 58.3 mm). A trend for negative correlation between the number of follicles and transferred embryos and the gingival index, before and after IVF respectively, was recorded in all women. There was a similar trend with bleeding on probing after IVF in women with periodontitis. Periodontal clinical parameters worsened in women undergoing IVF treatment. On the other hand, a poor pre-existing periodontal status seems to be associated with poorer outcomes of IVF treatment.
Formant-frequency variation and its effects on across-formant grouping in speech perception.
Roberts, Brian; Summers, Robert J; Bailey, Peter J
2013-01-01
How speech is separated perceptually from other speech remains poorly understood. In a series of experiments, perceptual organisation was probed by presenting three-formant (F1+F2+F3) analogues of target sentences dichotically, together with a competitor for F2 (F2C), or for F2+F3, which listeners must reject to optimise recognition. To control for energetic masking, the competitor was always presented in the opposite ear to the corresponding target formant(s). Sine-wave speech was used initially, and different versions of F2C were derived from F2 using separate manipulations of its amplitude and frequency contours. F2Cs with time-varying frequency contours were highly effective competitors, whatever their amplitude characteristics, whereas constant-frequency F2Cs were ineffective. Subsequent studies used synthetic-formant speech to explore the effects of manipulating the rate and depth of formant-frequency change in the competitor. Competitor efficacy was not tuned to the rate of formant-frequency variation in the target sentences; rather, the reduction in intelligibility increased with competitor rate relative to the rate for the target sentences. Therefore, differences in speech rate may not be a useful cue for separating the speech of concurrent talkers. Effects of competitors whose depth of formant-frequency variation was scaled by a range of factors were explored using competitors derived either by inverting the frequency contour of F2 about its geometric mean (plausibly speech-like pattern) or by using a regular and arbitrary frequency contour (triangle wave, not plausibly speech-like) matched to the average rate and depth of variation for the inverted F2C. Competitor efficacy depended on the overall depth of frequency variation, not depth relative to that for the other formants. Furthermore, the triangle-wave competitors were as effective as their more speech-like counterparts. Overall, the results suggest that formant-frequency variation is critical for the across-frequency grouping of formants but that this grouping does not depend on speech-specific constraints.
Recommended Practice for Use of Emissive Probes in Electric Propulsion Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheehan, J. P.; Raitses, Yevgeny; Hershkowitz, Noah
Here, this article provides recommended methods for building, operating, and taking plasma potential measurements from electron-emitting probes in electric propulsion devices, including Hall thrusters, gridded ion engines, and others. The two major techniques, the floating point technique and the inflection point technique, are described in detail as well as calibration and error-reduction methods. The major heating methods are described as well as the various considerations for emissive probe construction. Lastly, special considerations for electric propulsion plasmas are addressed, including high-energy densities, ion flows, magnetic fields, and potential fluctuations. Recommendations for probe design and operation are provided.
Recommended Practice for Use of Emissive Probes in Electric Propulsion Testing
Sheehan, J. P.; Raitses, Yevgeny; Hershkowitz, Noah; ...
2016-11-03
Here, this article provides recommended methods for building, operating, and taking plasma potential measurements from electron-emitting probes in electric propulsion devices, including Hall thrusters, gridded ion engines, and others. The two major techniques, the floating point technique and the inflection point technique, are described in detail as well as calibration and error-reduction methods. The major heating methods are described as well as the various considerations for emissive probe construction. Lastly, special considerations for electric propulsion plasmas are addressed, including high-energy densities, ion flows, magnetic fields, and potential fluctuations. Recommendations for probe design and operation are provided.
Depth as an organizer of fish assemblages in floodplain lakes
Miranda, L.E.
2011-01-01
Depth reduction is a natural process in floodplain lakes, but in many basins has been accelerated by anthropogenic disturbances. A diverse set of 42 floodplain lakes in the Yazoo River Basin (Mississippi, USA) was examined to test the hypothesis of whether depth reduction was a key determinant of water quality and fish assemblage structure. Single and multiple variable analyses were applied to 10 commonly monitored water variables and 54 fish species. Results showed strong associations between depth and water characteristics, and between depth and fish assemblages. Deep lakes provided less variable environments, clearer water, and a wider range of microhabitats than shallow lakes. The greater environmental stability was reflected by the dominant species in the assemblages, which included a broader representation of large-body species, species less tolerant of extreme water quality, and more predators. Stability in deep lakes was further reflected by reduced among-lake variability in taxa representation. Fish assemblages in shallow lakes were more variable than deep lakes, and commonly dominated by opportunistic species that have early maturity, extended breeding seasons, small adult size, and short lifespan. Depth is a causal factor that drives many physical and chemical variables that contribute to organizing fish assemblages in floodplain lakes. Thus, correlations between fish and water transparency, temperature, oxygen, trophic state, habitat structure, and other environmental descriptors may ultimately be totally or partly regulated by depth. In basins undergoing rapid anthropogenic modifications, local changes forced by depth reductions may be expected to eliminate species available from the regional pool and could have considerable ecological implications. ?? 2010 Springer Basel AG (outside the USA).
Dividers for reduction of aerodynamic drag of vehicles with open cavities
NASA Technical Reports Server (NTRS)
Storms, Bruce L. (Inventor)
2007-01-01
A drag-reduction concept for vehicles with open cavities includes dividing a cavity into smaller adjacent cavities through installation of one or more vertical dividers. The dividers may extend the full depth of the cavity or only partial depth. In either application, the top of the dividers are typically flush with the top of the bed or cargo bay of the vehicle. The dividers may be of any material, but are strong enough for both wind loads and forces encountered during cargo loading/unloading. For partial depth dividers, a structural angle may be desired to increase strength.
Siddiqui, EJ; Ali, S; Koneru, S
2006-01-01
INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424
Nascimento, Gustavo A; Souza, Elaine V M; Campos-Ferreira, Danielly S; Arruda, Mariana S; Castelletti, Carlos H M; Wanderley, Marcela S O; Ekert, Marek H F; Bruneska, Danyelly; Lima-Filho, José L
2012-01-01
A new electrochemical DNA biosensor for bovine papillomavirus (BPV) detection that was based on screen-printed electrodes was comprehensively studied by electrochemical methods of cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A BPV probe was immobilised on a working electrode (gold) modified with a polymeric film of poly-L-lysine (PLL) and chitosan. The experimental design was carried out to evaluate the influence of polymers, probe concentration (BPV probe) and immobilisation time on the electrochemical reduction of methylene blue (MB). The polymer poly-L-lysine (PLL), a probe concentration of 1 μM and an immobilisation time of 60 min showed the best result for the BPV probe immobilisation. With the hybridisation of a complementary target sequence (BPV target), the electrochemical signal decreased compared to a BPV probe immobilised on the modified PLL-gold electrode. Viral DNA that was extracted from cattle with papillomatosis also showed a decrease in the MB electrochemical reduction, which suggested that the decreased electrochemical signal corresponded to a bovine papillomavirus infection. The hybridisation specificity experiments further indicated that the biosensor could discriminate the complementary sequence from the non-complementary sequence. Thus, the results showed that the development of analytical devices, such as a biosensor, could assist in the rapid and efficient detection of bovine papillomavirus DNA and help in the prevention and treatment of papillomatosis in cattle. Copyright © 2012 Elsevier B.V. All rights reserved.
Pictorial depth probed through relative sizes
Wagemans, Johan; van Doorn, Andrea J; Koenderink, Jan J
2011-01-01
In the physical environment familiar size is an effective depth cue because the distance from the eye to an object equals the ratio of its physical size to its angular extent in the visual field. Such simple geometrical relations do not apply to pictorial space, since the eye itself is not in pictorial space, and consequently the notion “distance from the eye” is meaningless. Nevertheless, relative size in the picture plane is often used by visual artists to suggest depth differences. The depth domain has no natural origin, nor a natural unit; thus only ratios of depth differences could have an invariant significance. We investigate whether the pictorial relative size cue yields coherent depth structures in pictorial spaces. Specifically, we measure the depth differences for all pairs of points in a 20-point configuration in pictorial space, and we account for these observations through 19 independent parameters (the depths of the points modulo an arbitrary offset), with no meaningful residuals. We discuss a simple formal framework that allows one to handle individual differences. We also compare the depth scale obtained by way of this method with depth scales obtained in totally different ways, finding generally good agreement. PMID:23145258
NASA Astrophysics Data System (ADS)
Xie, M.; Mayer, U. K.; MacQuarrie, K. T. B.
2017-12-01
Water with total dissolved sulfide in excess of 1 mmol L-1is widely found in groundwater at intermediate depths in sedimentary basins, including regions of the Michigan basin in southeastern Ontario, Canada. Conversely, at deeper and shallower depths, relatively low total dissolved sulfide concentrations have been reported. The mechanisms responsible for the occurrence of these brackish sulfide-containing waters are not fully understood. Anaerobic microbial sulfate reduction is a common process resulting in the formation of high sulfide concentrations. Sulfate reduction rates depend on many factors including the concentration of sulfate, the abundance of organic substances, redox conditions, temperature, salinity and the species of sulfate reducing bacteria (SRB). A sedimentary basin-specific conceptual model considering the effect of salinity on the rate of sulfate reduction was developed and implemented in the reactive transport model MIN3P-THCm. Generic 2D basin-scale simulations were undertaken to provide a potential explanation for the dissolved sulfide distribution observed in the Michigan basin. The model is 440 km in the horizontal dimension and 4 km in depth, and contains fourteen sedimentary rock units including shales, sandstones, limestones, dolostone and evaporites. The main processes considered are non-isothermal density dependent flow, kinetically-controlled mineral dissolution/precipitation and its feedback on hydraulic properties, cation exchange, redox reactions, biogenic sulfate reduction, and hydromechanical coupling due to glaciation-deglaciation events. Two scenarios were investigated focusing on conditions during an interglacial period and the transient evolution during a glaciation-deglaciation cycle. Inter-glaciation simulations illustrate that the presence of high salinity brines strongly suppress biogenic sulfate reduction. The transient simulations show that glaciation-deglaciation cycles can have an impact on the maximum depth of elevated sulfide concentrations due to freshwater ingress and enhanced mixing. In all simulations the highest concentrations of total sulfide occur at depths of approximately 150 m, while concentrations at depths greater than 300 m typically remain below 0.03 mmol L-1, comparing well with observational data.
Papaspyrou, Sokratis; Smith, Cindy J.; Dong, Liang F.; Whitby, Corinne; Dumbrell, Alex J.; Nedwell, David B.
2014-01-01
Denitrification and dissimilatory nitrate reduction to ammonium (DNRA) are processes occurring simultaneously under oxygen-limited or anaerobic conditions, where both compete for nitrate and organic carbon. Despite their ecological importance, there has been little investigation of how denitrification and DNRA potentials and related functional genes vary vertically with sediment depth. Nitrate reduction potentials measured in sediment depth profiles along the Colne estuary were in the upper range of nitrate reduction rates reported from other sediments and showed the existence of strong decreasing trends both with increasing depth and along the estuary. Denitrification potential decreased along the estuary, decreasing more rapidly with depth towards the estuary mouth. In contrast, DNRA potential increased along the estuary. Significant decreases in copy numbers of 16S rRNA and nitrate reducing genes were observed along the estuary and from surface to deeper sediments. Both metabolic potentials and functional genes persisted at sediment depths where porewater nitrate was absent. Transport of nitrate by bioturbation, based on macrofauna distributions, could only account for the upper 10 cm depth of sediment. A several fold higher combined freeze-lysable KCl-extractable nitrate pool compared to porewater nitrate was detected. We hypothesised that his could be attributed to intracellular nitrate pools from nitrate accumulating microorganisms like Thioploca or Beggiatoa. However, pyrosequencing analysis did not detect any such organisms, leaving other bacteria, microbenthic algae, or foraminiferans which have also been shown to accumulate nitrate, as possible candidates. The importance and bioavailability of a KCl-extractable nitrate sediment pool remains to be tested. The significant variation in the vertical pattern and abundance of the various nitrate reducing genes phylotypes reasonably suggests differences in their activity throughout the sediment column. This raises interesting questions as to what the alternative metabolic roles for the various nitrate reductases could be, analogous to the alternative metabolic roles found for nitrite reductases. PMID:24728381
A Pursuit Theory Account for the Perception of Common Motion in Motion Parallax.
Ratzlaff, Michael; Nawrot, Mark
2016-09-01
The visual system uses an extraretinal pursuit eye movement signal to disambiguate the perception of depth from motion parallax. Visual motion in the same direction as the pursuit is perceived nearer in depth while visual motion in the opposite direction as pursuit is perceived farther in depth. This explanation of depth sign applies to either an allocentric frame of reference centered on the fixation point or an egocentric frame of reference centered on the observer. A related problem is that of depth order when two stimuli have a common direction of motion. The first psychophysical study determined whether perception of egocentric depth order is adequately explained by a model employing an allocentric framework, especially when the motion parallax stimuli have common rather than divergent motion. A second study determined whether a reversal in perceived depth order, produced by a reduction in pursuit velocity, is also explained by this model employing this allocentric framework. The results show than an allocentric model can explain both the egocentric perception of depth order with common motion and the perceptual depth order reversal created by a reduction in pursuit velocity. We conclude that an egocentric model is not the only explanation for perceived depth order in these common motion conditions. © The Author(s) 2016.
Granular convection observed by magnetic resonance imaging.
Ehrichs, E E; Jaeger, H M; Karczmar, G S; Knight, J B; Kuperman, V Y; Nagel, S R
1995-03-17
Vibrations in a granular material can spontaneously produce convection rolls reminiscent of those seen in fluids. Magnetic resonance imaging provides a sensitive and noninvasive probe for the detection of these convection currents, which have otherwise been difficult to observe. A magnetic resonance imaging study of convection in a column of poppy seeds yielded data about the detailed shape of the convection rolls and the depth dependence of the convection velocity. The velocity was found to decrease exponentially with depth; a simple model for this behavior is presented here.
Effects of multiple scattering on time- and depth-resolved signals in airborne lidar systems
NASA Technical Reports Server (NTRS)
Punjabi, A.; Venable, D. D.
1986-01-01
A semianalytic Monte Carlo radiative transfer model (SALMON) is employed to probe the effects of multiple-scattering events on the time- and depth-resolved lidar signals from homogeneous aqueous media. The effective total attenuation coefficients in the single-scattering approximation are determined as functions of dimensionless parameters characterizing the lidar system and the medium. Results show that single-scattering events dominate when these parameters are close to their lower bounds and that when their values exceed unity multiple-scattering events dominate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hornbach, Matthew J; Colwell, Frederick S; Harris, Robert
Methane Hydrates, a solid form of methane and water, exist at high pressures and low temperatures, occurs on every continental margin on Earth, represents one of the largest reservoirs of carbon on the planet, and, if destabilized, may play an important role in both slope stability and climate change. For decades, researchers have studied methane hydrates with the hope of determining if methane hydrates are destabilizing, and if so, how this destabilization might impact slope stability and ocean/atmosphere carbon budgets. In the past ~5 years, it has become well established that the upper “feather-edge” of methane hydrate stability (intermediate watermore » depths of ~200-500 meters below sea level) represents an important frontier for methane hydrates stability research, as this zone is most susceptible to destabilization due to minor fluctuations in ocean temperature in space and time. The Arctic Ocean—one of the fastest warming regions on Earth—is perhaps the best place to study possible changes to methane hydrate stability due to ocean warming. To address the stability of methane hydrates at intermediate ocean depths, Southern Methodist University in partnership with Oregon State University and The United State Geological Survey at Woods Hole began investigating methane hydrate stability in intermediate water depths below both the US Beaufort Sea and the Atlantic Margin, from 2012-2017. The work was funded by the Department of Energy’s (DOE) National Energy Technology Laboratory (NETL). The key goal of the SMU component of this study was to collect the first ever heat flow data in the Beaufort Sea and compare measured shallow (probe-based1) heat flow values with deeper (BSR-derived2) heat flow values, and from this, determine whether hydrates were in thermal equilibrium. In September 2016, SMU/OSU collected the first ever heat flow measurements in the US Beaufort Sea. Despite poor weather and rough seas, the cruise was a success, with 116 heat flow measurements acquired across the margin, spanning 4 transects separated by more than 400 km. Useable heat flow data exists for 97% (113) of probe heat flow measurements, revealing a clear picture of regional heat flow across the basin. During the past 8 months since the cruise, SMU researchers have processed the heat flow and thermal conductivity measurements and compared results to deeper heat flow estimates obtained from seismic data. The analysis reveals clear, consistent trends: All probe heat flow measurements in depths greater than 800 mbsl are consistent with BSR-derived values; heat flow measurements obtained in water depths between ~250-750 mbsl are systematically lower than those estimated from BSRs; and heat flow estimates in water depths shallower than ~250 mbsl are systematically warmer than deeper estimates. The consistency between shallow (probe) and deep (BSR) heat flow measurements at depths greater than ~750 m where ocean temperature changes are minimal supports the premise that the hydrates consist primarily of methane and represent a valuable tool for estimating heat flow. The anomalous cooling trend observed in the upper 250 m is consistent with expected seasonal effects observed in shallow ocean buoy measurements in the arctic, when cold, less dense melting sea ice cools the upper 200 m of the ocean during the summer as ice melting occurs. The discrepancy in heat flow at intermediate water depths is best explained via recent intermediate ocean temperature warming, where long-term (annual or longer) warming intermediate ocean bottom waters result in an anomalously low heat flow in shallow heat flow measurements. Using the characteristic 1D time-length scale for diffusion, we estimate that ocean temperature warming began no later than ~1200 years ago but arguably much more recently as results are limited by seismic resolution. More importantly, our analysis indicates methane hydrate is destabilizing not only in the upper feather edge (200-500 mbsl) but at depths as great as 750 mbsl. The intermediate ocean warming rate supports previous studies suggesting geologically rapid warming (>0.1 deg C/decade) at intermediate ocean depths in the Beaufort Sea. Assuming no further changes or additional warming, our analysis indicates methane hydrates will destabilize at seafloor depths shallower than 750 mbsl in the Beaufort Sea within the next ~3000 years. 1 Probe outfitted with sensors inserted into the seafloor sediment 2 Bottom-simulating reflector (BSR) seismic data indicates presence of hydrate deposits« less
NASA Technical Reports Server (NTRS)
Rosen, Charles D.; Mitchell, Shirley M.; Jolly, Stanley R.; Jackson, Richard G.; Fleming, Scott T.; Roberts, William J.; Bell, Daniel R., III
1996-01-01
Instrument yielding presence or absence of waterproofing agent at any given depth in blanket developed. In original application, blankets in question part of space shuttle thermal protection system. Instrument utilized to determine extent of waterproofing "burnout" due to re-entry heating and adverse environment exposure.
Giannobile, William V; Jung, Ronald E; Schwarz, Frank
2018-03-01
The goal of Working Group 1 at the 2nd Consensus Meeting of the Osteology Foundation was to comprehensively assess the effects of soft tissue augmentation procedures on peri-implant health or disease. A systematic review and meta-analysis on the effects of soft tissue augmentation procedures included a total of 10 studies (mucosal thickness: n = 6; keratinized tissue: n = 4). Consensus statements, clinical recommendations, and implications for future research were based on structured group discussions and a plenary session approval. Soft tissue grafting to increase the width of keratinized tissue around implants was associated with greater reductions in gingival and plaque indices when compared to non-augmented sites. Statistically significant differences were noted for final marginal bone levels in favor of an apically positioned flap plus autogenous graft vs. all standard-of-care control treatments investigated. Soft tissue grafting (i.e., autogenous connective tissue) to increase the mucosal thickness around implants in the aesthetic zone was associated with significantly less marginal bone loss over time, but no significant changes in bleeding on probing, probing depths, or plaque scores when compared to sites without grafting. The limited evidence available supports the use of soft tissue augmentation procedures to promote peri-implant health. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Coffee consumption and periodontal disease in males.
Ng, Nathan; Kaye, Elizabeth Krall; Garcia, Raul I
2014-08-01
Coffee is a major dietary source of antioxidants as well as of other anti-inflammatory factors. Given the beneficial role of such factors in periodontal disease, whether coffee intake is associated with periodontal disease in adult males was explored. Existing data collected by a prospective, closed-panel cohort study of aging and oral health in adult males was used. Participants included the 1,152 dentate males in the Veterans Affairs (VA) Dental Longitudinal Study who presented for comprehensive medical and dental examinations from 1968 to 1998. Mean age at baseline was 48 years; males were followed for up to 30 years. Participants are not VA patients; rather, they receive their medical and dental care in the private sector. Periodontal status was assessed by probing depth (PD), bleeding on probing, and radiographic alveolar bone loss (ABL), measured on intraoral periapical radiographs with a modified Schei ruler method. Moderate-to-severe periodontal disease was defined as cumulative numbers of teeth exhibiting PD ≥4 mm or ABL ≥40%. Coffee intake was obtained from participant self-reports using the Cornell Medical Index and food frequency questionnaires. Multivariate repeated-measures generalized linear models estimated mean number of teeth with moderate-to-severe disease at each examination by coffee intake level. It was found that higher coffee consumption was associated with a small but significant reduction in number of teeth with periodontal bone loss. No evidence was found that coffee consumption was harmful to periodontal health. Coffee consumption may be protective against periodontal bone loss in adult males.
Nguyen, Naomi-Trang; Byarlay, Matthew R; Reinhardt, Richard A; Marx, David B; Meinberg, Trudy A; Kaldahl, Wayne B
2015-10-01
Numerous studies have documented the clinical outcomes of laser therapy for untreated periodontitis, but very few have reported on lasers treating inflamed pockets during maintenance therapy. The aim of this study is to compare the effectiveness of scaling and root planing (SRP) plus the adjunctive use of diode laser therapy to SRP alone on changes in the clinical parameters of disease and on the gingival crevicular fluid (GCF) inflammatory mediator interleukin-1β (IL-1β) in patients receiving regular periodontal maintenance therapy. This single-masked and randomized, controlled, prospective study includes 22 patients receiving regular periodontal maintenance therapy who had one or more periodontal sites with a probing depth (PD) ≥ 5 mm with bleeding on probing (BOP). Fifty-six sites were treated with SRP and adjunctive laser therapy (SRP + L). Fifty-eight sites were treated with SRP alone. Clinical parameters, including PD, clinical attachment level (CAL), and BOP, and GCF IL-1β levels were measured immediately before treatment (baseline) and 3 months after treatment. Sites treated with SRP + L and SRP alone resulted in statistically significant reductions in PD and BOP and gains in CAL. These changes were not significantly different between the two therapies. Similarly, differences in GCF IL-1β levels between SRP + L and SRP alone were not statistically significant. In periodontal maintenance patients, SRP + L did not enhance clinical outcomes compared to SRP alone in the treatment of inflamed sites with ≥ 5 mm PD.
Photoswitchable non-fluorescent thermochromic dye-nanoparticle hybrid probes.
Harrington, Walter N; Haji, Mwafaq R; Galanzha, Ekaterina I; Nedosekin, Dmitry A; Nima, Zeid A; Watanabe, Fumiya; Ghosh, Anindya; Biris, Alexandru S; Zharov, Vladimir P
2016-11-08
Photoswitchable fluorescent proteins with controllable light-dark states and spectral shifts in emission in response to light have led to breakthroughs in the study of cell biology. Nevertheless, conventional photoswitching is not applicable for weakly fluorescent proteins and requires UV light with low depth penetration in bio-tissue. Here we introduce a novel concept of photoswitchable hybrid probes consisting of thermochromic dye and absorbing nanoparticles, in which temperature-sensitive light-dark states and spectral shifts in absorption can be switched through controllable photothermal heating of doped nanoparticles. The proof-of-concept is demonstrated through the use of two different types of temperature-sensitive dyes doped with magnetic nanoparticles and reversibly photoswitched by a near-infrared laser. Photoacoustic imaging revealed the high contrast of these probes, which is sufficient for their visualization in cells and deep tissue. Our results suggest that these new photoswitchable multicolour probes can be used for multimodal cellular diagnostics and potentially for magnetic and photothermal therapy.
Photoswitchable non-fluorescent thermochromic dye-nanoparticle hybrid probes
NASA Astrophysics Data System (ADS)
Harrington, Walter N.; Haji, Mwafaq R.; Galanzha, Ekaterina I.; Nedosekin, Dmitry A.; Nima, Zeid A.; Watanabe, Fumiya; Ghosh, Anindya; Biris, Alexandru S.; Zharov, Vladimir P.
2016-11-01
Photoswitchable fluorescent proteins with controllable light-dark states and spectral shifts in emission in response to light have led to breakthroughs in the study of cell biology. Nevertheless, conventional photoswitching is not applicable for weakly fluorescent proteins and requires UV light with low depth penetration in bio-tissue. Here we introduce a novel concept of photoswitchable hybrid probes consisting of thermochromic dye and absorbing nanoparticles, in which temperature-sensitive light-dark states and spectral shifts in absorption can be switched through controllable photothermal heating of doped nanoparticles. The proof-of-concept is demonstrated through the use of two different types of temperature-sensitive dyes doped with magnetic nanoparticles and reversibly photoswitched by a near-infrared laser. Photoacoustic imaging revealed the high contrast of these probes, which is sufficient for their visualization in cells and deep tissue. Our results suggest that these new photoswitchable multicolour probes can be used for multimodal cellular diagnostics and potentially for magnetic and photothermal therapy.
Bharadwaj, Reshma; Sai, V V R; Thakare, Kamini; Dhawangale, Arvind; Kundu, Tapanendu; Titus, Susan; Verma, Pradeep Kumar; Mukherji, Soumyo
2011-03-15
A novel label-free technique for the detection of pathogens based on evanescent wave absorbance (EWA) changes at 280 nm from a U-bent optical fiber sensor is demonstrated. Bending a decladded fiber into a U-shaped structure enhances the penetration depth of evanescent waves and hence sensitivity of the probe. We show that the enhanced EWA response from such U-bent probes, caused by the inherent optical absorbance properties of bacterial cells or biomolecules specifically bound to the sensor surface, can be exploited for the detection of pathogens. A portable optical set-up with a UV light emitting diode, a spectrometer and U-bent fiber optic probe of 200 μm core diameter, 0.75 mm bend radius and effective probe length of 1cm demonstrated an ability to detect less than 1000 cfu/ml. Copyright © 2011. Published by Elsevier B.V.
Yi, Hyunjung; Ghosh, Debadyuti; Ham, Moon-Ho; Qi, Jifa; Barone, Paul W; Strano, Michael S; Belcher, Angela M
2012-03-14
Second near-infrared (NIR) window light (950-1400 nm) is attractive for in vivo fluorescence imaging due to its deep penetration depth in tissues and low tissue autofluorescence. Here we show genetically engineered multifunctional M13 phage can assemble fluorescent single-walled carbon nanotubes (SWNTs) and ligands for targeted fluorescence imaging of tumors. M13-SWNT probe is detectable in deep tissues even at a low dosage of 2 μg/mL and up to 2.5 cm in tissue-like phantoms. Moreover, targeted probes show specific and up to 4-fold improved uptake in prostate specific membrane antigen positive prostate tumors compared to control nontargeted probes. This M13 phage-based second NIR window fluorescence imaging probe has great potential for specific detection and therapy monitoring of hard-to-detect areas. © 2012 American Chemical Society
HAM, MOON-HO; QI, JIFA; BARONE, PAUL W.; STRANO, MICHAEL S.; BELCHER, ANGELA M.
2014-01-01
Second near-infrared (NIR) window light (950-1,400 nm) is attractive for in vivo fluorescence imaging due to its deep penetration depth in tissues and low tissue autofluorescence. Here we show genetically engineered multifunctional M13 phage can assemble fluorescent single-walled carbon nanotubes (SWNTs) and ligands for targeted fluorescence imaging of tumors. M13-SWNT probe is detectable in deep tissues even at a low dosage of 2 μg/mL and up to 2.5 cm in tissue-like phantoms. Moreover, targeted probes show specific and up to four-fold improved uptake in prostate specific membrane antigen positive prostate tumors compared to control non-targeted probes. This M13 phage-based second NIR window fluorescence imaging probe has great potential for specific detection and therapy monitoring of hard-to-detect areas. PMID:22268625
NASA Astrophysics Data System (ADS)
Kaufman, Lloyd; Williamson, Samuel J.; Costaribeiro, P.
1988-02-01
Recently developed small arrays of SQUID-based magnetic sensors can, if appropriately placed, locate the position of a confined biomagnetic source without moving the array. The authors present a technique with a relative accuracy of about 2 percent for calibrating such sensors having detection coils with the geometry of a second-order gradiometer. The effects of calibration error and magnetic noise on the accuracy of locating an equivalent current dipole source in the human brain are investigated for 5- and 7-sensor probes and for a pair of 7-sensor probes. With a noise level of 5 percent of peak signal, uncertainties of about 20 percent in source strength and depth for a 5-sensor probe are reduced to 8 percent for a pair of 7-sensor probes, and uncertainties of about 15 mm in lateral position are reduced to 1 mm, for the configuration considered.
Geochemical control on the reduction of U(VI) to mononuclear U(IV) species in lacustrine sediments
NASA Astrophysics Data System (ADS)
Stetten, L.; Mangeret, A.; Brest, J.; Seder-Colomina, M.; Le Pape, P.; Ikogou, M.; Zeyen, N.; Thouvenot, A.; Julien, A.; Alcalde, G.; Reyss, J. L.; Bombled, B.; Rabouille, C.; Olivi, L.; Proux, O.; Cazala, C.; Morin, G.
2018-02-01
Contaminated systems in which uranium (U) concentrations slightly exceed the geochemical background are of particular interest to identify natural processes governing U trapping and accumulation in Earth's surface environments. For this purpose, we examined the role of early diagenesis on the evolution of U speciation and mobility in sediments from an artificial lake located downstream from a former mining site. Sediment and pore water chemistry together with U and Fe solid state speciation were analyzed in sediment cores sampled down to 50 cm depth at four locations in the lake. These organic-rich sediments (∼12% organic C) exhibited U concentrations in the 40-80 mg kg-1 range. The sediment columns were anoxic 2-3 mm below the sediment-water interface and pore waters pH was circumneutral. Pore water chemistry profiles showed that organic carbon mineralization was associated with Fe and Mn reduction and was correlated with a decrease in dissolved U concentration with depth. Immobilization of U in the sediment was correlated with the reduction of U(VI) to U(IV) at depth, as shown by U LIII-edge XANES spectroscopic analysis. XANES and EXAFS spectroscopy at the Fe K-edge showed the reduction of structural Fe(III) to Fe(II) in phyllosilicate minerals with depth, coincident with U(VI) to U(IV) reduction. Thermodynamic modeling suggests that Fe(II) could act as a major reducing agent for U(VI) during early diagenesis of these sediments, leading to complete U reduction below ∼30 cm depth. Shell-by-shell and Cauchy-Wavelet analysis of U LIII-EXAFS spectra indicates that U(VI) and U(IV) are mainly present as mononuclear species bound to C, P or Si ligands. Chemical extractions confirmed that ∼60-80% of U was present as non-crystalline species, which emphasizes that such species should be considered when evaluating the fate of U in lacustrine environments and the efficiency of sediment remediation strategies.
NASA Astrophysics Data System (ADS)
He, Wei; McConnell, George C.; Bellamkonda, Ravi V.
2006-12-01
Neural electrodes could significantly enhance the quality of life for patients with sensory and/or motor deficits as well as improve our understanding of brain functions. However, long-term electrical connectivity between neural tissue and recording sites is compromised by the development of astroglial scar around the recording probes. In this study we investigate the effect of a nanoscale laminin (LN) coating on Si-based neural probes on chronic cortical tissue reaction in a rat model. Tissue reaction was evaluated after 1 day, 1 week, and 4 weeks post-implant for coated and uncoated probes using immunohistochemical techniques to evaluate activated microglia/macrophages (ED-1), astrocytes (GFAP) and neurons (NeuN). The coating did not have an observable effect on neuronal density or proximity to the electrode surface. However, the response of microglia/macrophages and astrocytes was altered by the coating. One day post-implant, we observed an ~60% increase in ED-1 expression near LN-coated probe sites compared with control uncoated probe sites. Four weeks post-implant, we observed an ~20% reduction in ED-1 expression along with an ~50% reduction in GFAP expression at coated relative to uncoated probe sites. These results suggest that LN has a stimulatory effect on early microglia activation, accelerating the phagocytic function of these cells. This hypothesis is further supported by the increased mRNA expression of several pro-inflammatory cytokines (TNF-α, IL-1 and IL-6) in cultured microglia on LN-bound Si substrates. LN immunostaining of coated probes immediately after insertion and retrieval demonstrates that the coating integrity is not compromised by the shear force during insertion. We speculate, based on these encouraging results, that LN coating of Si neural probes could potentially improve chronic neural recordings through dispersion of the astroglial scar.
Jespersen, Bente; Møldrup, Ulla; Keller, Anna K.
2017-01-01
Background Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion. Methods In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were randomised to stepwise venous occlusion, complete venous occlusion, complete arterial occlusion or controls. Results All parameters were stable through baseline measurements. Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular occlusions on the vessel it was placed. Conclusions We developed a new model for stepwise renal venous blood flow occlusion. Furthermore, the first comparison of the implantable Doppler probe and microdialysis for detection of renal vascular occlusions was made. The implantable Doppler probe could only detect flow changes after a complete occlusion, whereas microdialysis detected changes earlier, and could detect both arterial and venous occlusion. Based on these results, the implantable Doppler probe for early detection of vascular occlusions cannot be recommended. PMID:28542429
Pressure as a limit to bloater (Coregonus hoyi) vertical migration
TeWinkel, Leslie M.; Fleischer, Guy W.
1998-01-01
Observations of bloater vertical migration showed a limit to the vertical depth changes that bloater experience. In this paper, we conducted an analysis of maximum differences in pressure encountered by bloater during vertical migration. Throughout the bottom depths studied, bloater experienced maximum reductions in swim bladder volume equal to approximately 50-60% of the volume in midwater. The analysis indicated that the limit in vertical depth change may be related to a maximum level of positive or negative buoyancy for which bloater can compensate using alternative mechanisms such as hydrodynamic lift. Bloater may be limited in the extent of migration by either their depth of neutral buoyancy or the distance above the depth of neutral buoyancy at which they can still maintain their position in the water column. Although a migration limit for the bloater population was evident, individual distances of migration varied at each site. These variations in migration distances may indicate differences in depths of neutral buoyancy within the population. However, in spite of these variations, the strong correlation between shallowest depths of migration and swim bladder volume reduction across depths provides evidence that hydrostatic pressure limits the extent of daily vertical movement in bloater.
Radio Frequency Signals in Jupiter's Atmosphere
Lanzerotti; Rinnert; Dehmel; Gliem; Krider; Uman; Bach
1996-05-10
During the Galileo probe's descent through Jupiter's atmosphere, under the ionosphere, the lightning and radio emission detector measured radio frequency signals at levels significantly above the probe's electromagnetic noise. The signal strengths at 3 and 15 kilohertz were relatively large at the beginning of the descent, decreased with depth to a pressure level of about 5 bars, and then increased slowly until the end of the mission. The 15-kilohertz signals show arrival direction anisotropies. Measurements of radio frequency wave forms show that the probe passed through an atmospheric region that did not support lightning within at least 100 kilometers and more likely a few thousand kilometers of the descent trajectory. The apparent opacity of the jovian atmosphere increases sharply at pressures greater than about 4 bars.
NASA Astrophysics Data System (ADS)
Merchel, Renée. A.; Barnes, Kelli S.; Taylor, Kenneth D.
2015-03-01
INTRODUCTION: The ABC® D-Flex Probe utilizes argon beam coagulation (ABC) technology to achieve hemostasis during minimally invasive surgery. A handle on the probe allows for integration with robotic surgical systems and introduces ABC to the robotic toolbox. To better understand the utility of D-Flex, this study compares the performance of the D-Flex probe to an existing ABC laparoscopic probe through ex vivo tissue analysis. METHODS: Comparisons were performed to determine the effect of four parameters: ABC device, tissue type, activation duration, and distance from tissue. Ten ABC D-Flex probes were used to create 30 burn samples for each comparison. Ex vivo bovine liver and porcine muscle were used as tissue models. The area and depth of each burn was measured using a light microscope. The resulting dimensional data was used to correlate tissue effect with each variable. RESULTS: D-Flex created burns which were smaller in surface area than the laparoscopic probe at all power levels. Additionally, D-Flex achieved thermal penetration levels equivalent to the laparoscopic probe. CONCLUSION: D-Flex implements a small 7F geometry which creates a more focused beam. When used with robotic precision, quick localized superficial hemostasis can be achieved with minimal collateral damage. Additionally, D-Flex achieved equivalent thermal penetration levels at lower power and argon flow-rate settings than the laparoscopic probe.
Singh, Kanwarpal; Reddy, Rohith; Sharma, Gargi; Verma, Yogesh; Gardecki, Joseph A; Tearney, Guillermo
2018-03-01
Endoscopic optical coherence tomography probes suffer from various artifacts due to dispersion imbalance and polarization mismatch between reference and sample arm light. Such artifacts can be minimized using a common path approach. In this work, we demonstrate a miniaturized common path probe for optical coherence tomography using an inline fiber mirror. A common path optical fiber probe suitable for performing high-resolution endoscopic optical coherence tomography imaging was developed. To achieve common path functionality, an inline fiber mirror was fabricated using a thin gold layer. A commercially available swept source engine was used to test the designed probe in a cadaver human coronary artery ex vivo. We achieved a sensitivity of 104 dB for this probe using a swept source optical coherence tomography system. To test the probe, images of a cadaver human coronary artery were obtained, demonstrating the quality that is comparable to those obtained by OCT systems with separate reference arms. Additionally, we demonstrate recovery of ranging depth by use of a Michelson interferometer in the detection path. We developed a miniaturized monolithic inline fiber mirror-based common path probe for optical coherence tomography. Owing to its simplicity, our design will be helpful in endoscopic applications that require high-resolution probes in a compact form factor while reducing system complexity. Lasers Surg. Med. 50:230-235, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
The riches of the cyclopean paradigm
NASA Astrophysics Data System (ADS)
Tyler, Christopher W.
2005-03-01
The cyclopean paradigm introduced by Bela Julesz remains one of the richest probes into the neural organization of sensory processing, by virtue of both its specificity for purely stereoscopic form and the sophistication of the processing required to retrieve it. The introduction of the sinusoidal stereograting showed that the perceptual limitations of human depth processing are very different from those for monocular form. Their use has also revealed the existence of hypercyclopean form channels selective for specific aspects of the monocularly invisible depth form. The natural extension of stereogratings to patches of stereoGabor ripple has allowed the measurement of the summation properties for depth structure, which is specific for narrow horizontal bars in depth. Consideration of the apparent motion between two cyclopean depth structures reveals the existence of a novel surface correspondence problem operating for cyclopean surfaces over time after the binocular correspondence has been solved. Such concepts imply that remains to be discovered about cyclopean stereopsis and its relationship to 3D form perception from other depth cues.
Tobisch, Sven
2017-01-01
An in-depth computational mechanistic probe of the CuH-mediated hydroamination of internal arylalkynes with an archetype hydroxylamine ester and hydrosilane by a (Xantphos)CuH catalyst (Xantphos ≡ {P^P} ≡ 4,5-bis(diphenylphosphino)-9,9-dimethylxanthene) is presented. This first comprehensive computational study of the CuH-mediated electrophilic alkyne hydroamination has identified the most accessible pathway for the rival avenues for direct and reductive hydroamination. The mechanistic picture derived from smooth energy profiles obtained by employing a reliable computational protocol applied to a realistic catalyst model conforms to all available experimental data. The crucial vinyl- and alkylcopper intermediates were found to display a distinct chemodivergence in their reactivity towards amine electrophile and alcohol, which ensures the successful formation of α-branched alkylamines together with (E)-enamines. On the one hand, the vinylcopper is somewhat preferably approached by the alcohol, thereby rendering the reductive hydroamination avenue favourable in the presence of both amine electrophile and alcohol. In contrast, the greater kinetic demands for protonation versus electrophilic amination predicted for the alkylcopper prevents the reductive hydroamination avenue to become non-productive. Electronically modified hydroxylamine esters are found to influence the chemoselectivity in reactivity towards amine electrophile and alcohol achievable for the vinyl- and alkylcopper, thereby offering an opportunity for process improvement. PMID:28660063
TH-AB-209-04: 3D Light Sheet Luminescence Imaging with Cherenkov Radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruza, P; Lin, H; Jarvis, L
Purpose: To recover a three-dimensional density distribution of luminescent molecular probes located several centimeters deep within a highly scattering tissue. Methods: We developed a novel sheet beam Cherenkov-excited luminescence scanned imaging (CELSI) methodology. The sample was irradiated by a horizontally oriented, vertically scanned 6 MV X-ray sheet beam (200mm × 5mm, 0.2mm vertical step) from a radiotherapy linear accelerator. The resulting Cherenkov light emission – and thus luminescent probe excitation – occurred exclusively along the irradiation plane due to a short diffusion path of secondary particles and Cherenkov photons. Cherenkov-excited luminescence was detected orthogonally to the sheet beam by gated,more » intensified charge coupled device camera. Analogously to light sheet microscopy, a series of luminescence images was taken for varied axial positions (depths) of the Cherenkov light sheet in sample. Knowledge of the excitation plane position allowed a 3D image stack deconvolution and depth-variant attenuation correction. The 3D image post-processing yielded a true spatial density distribution of luminescent molecules in highly scattering tissue. Results: We recovered a three-dimensional shape and position of 400 µL lesion-mimicking phantom tubes containing 25 µM solution of PtG4 molecular probe from 3 centimeter deep tissue-like media. The high sensitivity of CELSI also allowed resolving 100 micron capillaries of test solution. Functional information of partial oxygen pressure at the site of PtG4 molecular probe was recovered from luminescence lifetime CELSI. Finally, in-vivo sheet beam CELSI localized milimeter-sized PtG4-labelled tumor phantoms in multiple biological objects (hairless mice) from single scan. Conclusion: Presented sheet beam CELSI technique greatly extended the useful depth range of luminescence molecular imaging. More importantly, the light sheet microscopy approach was successfully adapted to CELSI, providing means to recover a completely attenuation-corrected 3D image of luminescent probe distribution. Gated CELSI acquisition yielded functional information of a spatially resolved oxygen concentration map of deep lying targets. This work was supported by NIH research grant R01CA109558 and R21EB017559, as well as by Pilot Grant Funds from the Norris Cotton Cancer Center.« less
Dreyfuss, Paul; Henning, Troy; Malladi, Niriksha; Goldstein, Barry; Bogduk, Nikolai
2009-01-01
To determine the physiologic effectiveness of multi-site, multi-depth sacral lateral branch injections. Double-blind, randomized, placebo-controlled study. Outpatient pain management center. Twenty asymptomatic volunteers. The dorsal innervation to the sacroiliac joint (SIJ) is from the L5 dorsal ramus and the S1-3 lateral branches. Multi-site, multi-depth lateral branch blocks were developed to compensate for the complex regional anatomy that limited the effectiveness of single-site, single-depth lateral branch injections. Bilateral multi-site, multi-depth lateral branch green dye injections and subsequent dissection on two cadavers revealed a 91% accuracy with this technique. Session 1: 20 asymptomatic subjects had a 25-g spinal needle probe their interosseous (IO) and dorsal sacroiliac (DSI) ligaments. The inferior dorsal SIJ was entered and capsular distension with contrast medium was performed. Discomfort had to occur with each provocation maneuver and a contained arthrogram was necessary to continue in the study. Session 2: 1 week later; computer randomized, double-blind multi-site, multi-depth lateral branch blocks injections were performed. Ten subjects received active (bupivicaine 0.75%) and 10 subjects received sham (normal saline) multi-site, multi-depth lateral branch injections. Thirty minutes later, provocation testing was repeated with identical methodology used in session 1. Presence or absence of pain for ligamentous probing and SIJ capsular distension. Seventy percent of the active group had an insensate IO and DSI ligaments, and inferior dorsal SIJ vs 0-10% of the sham group. Twenty percent of the active vs 10% of the sham group did not feel repeat capsular distension. Six of seven subjects (86%) retained the ability to feel repeat capsular distension despite an insensate dorsal SIJ complex. Multi-site, multi-depth lateral branch blocks are physiologically effective at a rate of 70%. Multi-site, multi-depth lateral branch blocks do not effectively block the intra-articular portion of the SIJ. There is physiological evidence that the intra-articular portion of the SIJ is innervated from both ventral and dorsal sources. Comparative multi-site, multi-depth lateral branch blocks should be considered a potentially valuable tool to diagnose extra-articular SIJ pain and determine if lateral branch radiofrequency neurotomy may assist one with SIJ pain.
Comparative Evaluation of Pain Scores during Periodontal Probing with or without Anesthetic Gels.
Mishra, Ashank; Priyanka, Mandapathi; Pradeep, Koppolu; Reddy Pathakota, Krishnajaneya
2016-01-01
Context. The initial periodontal examination which includes full-mouth periodontal probing is one of the discomforting procedures for a patient. Aim. To evaluate the efficacy of two local anesthetic gels in the reduction of pain during periodontal probing using Florida probe in CGP patients in comparison with manual probing. Materials and Methods. Ninety systemically healthy patients with moderate to severe CGP patients were recruited. In each patient, the quadrants were randomly assigned to manual probing with UNC-15 probe, probing with Florida probe, and Florida probing with lidocaine 10% gel and with benzocaine 20% gel. In the quadrants undergoing probing with anesthetic gels, the sites were isolated and the gel was injected using syringe and a blunt-end cannula. Pain was measured using 10 mm horizontal VAS. Statistical Analysis. The analysis was carried out using SPSS version 18. The comparison of mean VAS scores was done using repeated measures ANOVA with post hoc Bonferroni test. Results. Mean VAS for manual probing was significantly more than Florida probing. Further, the mean VAS score for Florida probing was higher than the two gels. Conclusion. It is suggested that the gels might be useful in reducing pain experienced during full-mouth periodontal probing in patients with CGP.
A new evaluation method of electron optical performance of high beam current probe forming systems.
Fujita, Shin; Shimoyama, Hiroshi
2005-10-01
A new numerical simulation method is presented for the electron optical property analysis of probe forming systems with point cathode guns such as cold field emitters and the Schottky emitters. It has long been recognized that the gun aberrations are important parameters to be considered since the intrinsically high brightness of the point cathode gun is reduced due to its spherical aberration. The simulation method can evaluate the 'threshold beam current I(th)' above which the apparent brightness starts to decrease from the intrinsic value. It is found that the threshold depends on the 'electron gun focal length' as well as on the spherical aberration of the gun. Formulas are presented to estimate the brightness reduction as a function of the beam current. The gun brightness reduction must be included when the probe property (the relation between the beam current l(b) and the probe size on the sample, d) of the entire electron optical column is evaluated. Formulas that explicitly consider the gun aberrations into account are presented. It is shown that the probe property curve consists of three segments in the order of increasing beam current: (i) the constant probe size region, (ii) the brightness limited region where the probe size increases as d approximately I(b)(3/8), and (iii) the angular current intensity limited region in which the beam size increases rapidly as d approximately I(b)(3/2). Some strategies are suggested to increase the threshold beam current and to extend the effective beam current range of the point cathode gun into micro ampere regime.
Mass Transport of Macromolecules within an In Vitro Model of Supragingival Plaque
Thurnheer, Thomas; Gmür, Rudolf; Shapiro, Stuart; Guggenheim, Bernhard
2003-01-01
The aim of this study was to examine the diffusion of macromolecules through an in vitro biofilm model of supragingival plaque. Polyspecies biofilms containing Actinomyces naeslundii, Fusobacterium nucleatum, Streptococcus oralis, Streptococcus sobrinus, Veillonella dispar, and Candida albicans were formed on sintered hydroxyapatite disks and then incubated at room temperature for defined periods with fluorescent markers with molecular weights ranging from 3,000 to 900,000. Subsequent examination by confocal laser scanning microscopy revealed that the mean square penetration depths for all tested macromolecules except immunoglobulin M increased linearly with time, diffusion coefficients being linearly proportional to the cube roots of the molecular weights of the probes (range, 10,000 to 240,000). Compared to diffusion in bulk water, diffusion in the biofilms was markedly slower. The rate of diffusion for each probe appeared to be constant and not a function of biofilm depth. Analysis of diffusion phenomena through the biofilms suggested tortuosity as the most probable explanation for retarded diffusion. Selective binding of probes to receptors present in the biofilms could not explain the observed extent of retardation of diffusion. These results are relevant to oral health, as selective attenuated diffusion of fermentable carbohydrates and acids produced within dental plaque is thought to be essential for the development of carious lesions. PMID:12620862
Light distribution modulated diffuse reflectance spectroscopy.
Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao
2016-06-01
Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation.
Light distribution modulated diffuse reflectance spectroscopy
Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao
2016-01-01
Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation. PMID:27375931
Perdikogianni, Hariklia; Papaioannou, William; Nakou, Melachrini; Oulis, Constantine; Papagiannoulis, Liza
2009-11-01
Objective. To evaluate the oral hygiene and the periodontal condition of children and adolescents with cleft lip and/or palate (CLP). Methods. Forty-one children and adolescents, 4-18 years, with CLP and 41 normal controls participated. Clinical parameters examined were the plaque and gingival index and Community Periodontal Index of Treatment Needs. For teeth in the cleft area, probing pocket depth, bleeding on probing, and tooth mobility were also evaluated. Samples of subgingival plaque were collected from 21 randomly selected patients of each group. Results. The CLP group had generally poorer oral hygiene (plaque index significantly higher) compared with the control. Children in both groups presented mild degree of gingivitis. Teeth in the cleft area had significantly higher pocket probing depth and tooth mobility, compared with corresponding teeth in the control group. The microbial analysis did not reveal significant differences in the composition of the subgingival microbiota between groups. Teeth in the cleft presented higher isolation frequencies and mean percentages of periodontopathic bacteria. Conclusion. Youngsters with CLP showed poor oral hygiene and worse periodontal condition, compared with controls. The above results advocate their participation in an intensive preventive dental programme that should start at an early age, possibly decreasing the risk of future periodontal disease.
NASA Astrophysics Data System (ADS)
Schleusener, J.; Reble, C.; Helfmann, J.; Gersonde, I.; Cappius, H.-J.; Glanert, M.; Fluhr, J. W.; Meinke, M. C.
2014-03-01
Two different designs for fibre-coupled Raman probes are presented that are optimized for discriminating cancerous and normal skin by achieving high epithelial sensitivity to detect a major component of the Raman signal from the depth range of the epithelium. This is achieved by optimizing Raman spot diameters to the range of ≈200 µm, which distinguishes this approach from the common applications of either Raman microspectroscopy (1-5 µm) or measurements on larger sampling volume using spot sizes of a few mm. Video imaging with a depicted area in the order of a few cm, to allow comparing Raman measurements to the location of the histo-pathologic findings, is integrated in both designs. This is important due to the inhomogeneity of cancerous lesions. Video image acquisition is achieved using white light LED illumination, which avoids ambient light artefacts. The design requirements focus either on a compact light-weight configuration, for pen-like handling, or on a video-visible measurement spot to enable increased positioning accuracy. Both probes are evaluated with regard to spot size, Rayleigh suppression, background fluorescence, depth sensitivity, clinical handling and ambient light suppression. Ex vivo measurements on porcine ear skin correlates well with findings of other groups.
Subgrade moisture & temperature variations under road pavements in Virginia.
DOT National Transportation Integrated Search
1974-01-01
In this investigation the changes in the subgrade moisture content under five road pavements ranging in age from new to about ten years old were determined and evaluated. The moisture content was determined by means of a nuclear moisture depth probe....
NASA Astrophysics Data System (ADS)
Nagihara, S.; Kiefer, W. S.; Taylor, P. T.; Williams, D. R.; Nakamura, Y.; Krell, J. W.
2017-12-01
The Apollo Heat Flow Experiment (HFE) was conducted at landing sites 15 and 17 as part of the Apollo Lunar Surface Experiment Package (ALSEP) program. At each site, the astronauts drilled 2 holes, 10-m apart, and installed a probe in each. The probes monitored surface and subsurface temperatures. The Apollo 15 probes operated from July 1971 to January 1977. The Apollo 17 probes operated from December 1972 to September 1977. For both sites, only data from the beginning to December 1974 were archived previously. We have restored major portions of the 1975-1977 HFE data for both sites from two sets of sources recently recovered. One was the original ALSEP archival data tapes, from which raw HFE data were extracted and processed according to the procedure and the calibration data specified by the original investigators. The other was the ALSEP Performance Summary Reports, which included weekly logs of temperature readings from the deepest sensor of each of the probes. The original HFE investigators noted that temperature of the regolith well below the thermal skin depth ( 1 m) rose gradually through December 1974 at both sites. Possible causes of the warming have been debated since. The restored 1975-1977 HFE data allow more detailed characterization of this phenomenon, especially for the Apollo 17 site, for which the duration of data availability has more than doubled. For both sites, the subsurface warming continued till the end of observations. Simultaneously, thermal gradient decreased. Such behavior is consistent with one of the hypotheses proposed by the original investigators; temperature of the lunar surface around the probe increased by 2 to 4 K at the time of deployment. Consequently, the subsurface thermal regime gradually adjusted to the new boundary condition. The Lunar Reconnaissance Orbiter Camera images taken over the Apollo landing sites suggest that astronaut-induced surface disturbance resulted in lower albedo, and that should have raised average surface temperature. Other explanations may also be possible. For example, at the Apollo 15 site, it is known that radiation down the hole affected the upper section of the probe. In contrast, the Apollo 17 probes were installed with radiation shields at the top of the hole and at 0.3-m depth. Therefore, warming there is more likely to be conductive in nature.
Periodontal disease in research beagle dogs--an epidemiological study.
Kortegaard, H E; Eriksen, T; Baelum, V
2008-12-01
To estimate the prevalence and describe the extent and severity of periodontal disease and associated periodontal parameters in beagle dogs. A full-mouth, site-specific examination was performed in 98 beagle dogs. Focus was placed on clinical attachment loss, pocket depth and bleeding on probing. The prevalence of clinical attachment loss greater than equal to 1 mm was 20 per cent in the one-year-old dogs, increasing to 84 per cent of the dogs aged more than three years. The number of sites affected with clinical attachment loss greater than equal to 1 mm showed a skewed distribution. The prevalence of clinical attachment loss greater than equal to 4 mm was only seven per cent. A probing pocket depth of 4+ mm was observed in 44 to 81 per cent of the dogs, depending on age. Also, the distribution of the number of deepened pockets/dog was skewed. The teeth most prone to clinical attachment loss greater than equal to 1 mm were the P2, the P3 and the P4 of the maxilla. The teeth most prone to pocket depth greater than equal to 4 mm were the maxillary canines. Periodontal disease in terms of clinical attachment loss greater than equal to 1 mm and pocket depth greater than equal to 4 mm is common in beagle dogs, but the major disease burden is carried by only a few dogs. The prevalence increases with increased age but is high already at the age of two years.
NASA Astrophysics Data System (ADS)
Snezhko, A.; Prozorov, R.; Lawrie, D. D.; Giannetta, R. W.; Gauthier, J.; Renaud, J.; Fournier, P.
2003-11-01
The low temperature behavior of magnetic penetration depth provides a powerful tool for probing of order parameter pairing symmetry. In the present work the in-pain London penetration depth, λ(T), measured down to 0.4K is reported for thin films of the Pr_2-xCe_xCuO_4-δ with varying doping levels (x = 0.13, 0.15 and 0.17). Measurements were carried out using a tunnel diode oscillator with excitation fields applied both perpendicular and parallel to the conducting planes. For all systems studied we have found that superfluid density exhibits power law behavior suggestive of a d-wave pairing with impurity scattering.
The Galileo probe Doppler wind experiment: Measurement of the deep zonal winds on Jupiter
NASA Astrophysics Data System (ADS)
Atkinson, David H.; Pollack, James B.; Seiff, Alvin
1998-09-01
During its descent into the upper atmosphere of Jupiter, the Galileo probe transmitted data to the orbiter for 57.5 min. Accurate measurements of the probe radio frequency, driven by an ultrastable oscillator, allowed an accurate time history of the probe motions to be reconstructed. Removal from the probe radio frequency profile of known Doppler contributions, including the orbiter trajectory, the probe descent velocity, and the rotation of Jupiter, left a measurable frequency residual due to Jupiter's zonal winds, and microdynamical motion of the probe from spin, swing under the parachute, atmospheric turbulence, and aerodynamic buffeting. From the assumption of the dominance of the zonal horizontal winds, the frequency residuals were inverted and resulted in the first in situ measurements of the vertical profile of Jupiter's deep zonal winds. A number of error sources with the capability of corrupting the frequency measurements or the interpretation of the frequency residuals were considered using reasonable assumptions and calibrations from prelaunch and in-flight testing. It is found that beneath the cloud tops (about 700 mbar) the winds are prograde and rise rapidly to 170 m/s at 4 bars. Beyond 4 bars to the depth at which the link with the probe was lost, nearly 21 bars, the winds remain constant and strong. Corrections for the high temperatures encountered by the probe have recently been completed and provide no evidence of diminishing or strengthening of the zonal wind profile in the deeper regions explored by the Galileo probe.
Porosity in low dielectric constant SiOCH films depth profiled by positron annihilation spectroscopy
NASA Astrophysics Data System (ADS)
Brusa, R. S.; Spagolla, M.; Karwasz, G. P.; Zecca, A.; Ottaviani, G.; Corni, F.; Bacchetta, M.; Carollo, E.
2004-03-01
The 3γ annihilation of orthopositronium and the Doppler broadening of the positron annihilation line have been measured by implanting low energy positrons in low dielectric constant (low-k) SiOCH films. The evolution and stability of film porosity with thermal treatments in the 400-900 °C temperature range has been studied. The films have been produced by plasma enhanced chemical vapor deposition and after annealing in N2 atmospheres at 480 °C have been treated in N2+He plasma. The minimum free volume of the pores in the as-produced samples has been estimated to correspond to that of a sphere with radius r=0.6 nm. The treatment in the N2 plasma was found to seal the pores up to 45 nm depth. Both the composition of the films (as obtained by Rutherford backscattering spectroscopy and elastic recoil detection analysis) and the chemical environment of the pores probed by positrons were found to be very stable up to 600 °C thermal treatment. Above such a temperature a reduction of the hydrogen content accompanied by a change in the structure and in the chemical environment of the pores has been observed. In the samples thermal treated at 800-900 °C, the positronium formation is reduced by one-third respect with the as produced sample. In the annealed and as-produced films, a natural aging of 30 days in air was enough to contaminate the porosity, as pointed out by a strong reduction of the 3γ annihilations. The effect of contamination and the distribution of the pores were completely recovered after a thermal treatment at 400 °C. Artificial aging of SiOCH films in controlled atmospheres of H2, O2, H2O has shown that H2O is the more efficient contaminant in reducing the effective volume of the pores.
Meza-Mauricio, Jonathan; Soto-Peñaloza, David; Peñarrocha-Oltra, David; Montiel-Company, Jose Maria; Peruzzo, Daiane Cristina
2018-06-12
This review aimed at evaluating the effects of chronic periodontitis (CP) treatment with local statins as adjuncts to scaling and root planing (SRP), compared with SRP alone or with placebo. Electronic and hand searches were conducted in three databases to select randomized controlled trials (RCTs) comparing SRP + statins versus SRP alone. Random effects models were conducted to determine the clinical attachment level (CAL) gain as the primary outcome variable, and probing pocket depth (PPD) reduction, modified sulcus bleeding index (mSBI), and intrabony defect depth (IBD) as the secondary outcomes. Of the 526 papers identified, 15 articles met the criteria for inclusion in this systematic review, and 13 in the meta-analysis. The meta-analysis showed a statistically significant CAL gain (mean differences [MD] = 1.84 mm, 95% confidence interval [CI] = 1.45 to 2.23; p = 0.000), PPD reduction (MD = 1.69 mm, 95% CI = 1.37 to 2.04; p = 0.000), mSBI change (MD = 0.70, 95% CI = 0.57 to 0.84; p = 0.000), and IBD (MD = 1.48, 95% CI = 1.30 to 1.67; p = 0.000) attributed to SRP + statin treatment (6 months). Within the limitations of this study, the collective evidence emerging from this systematic review and meta-analysis may support the use of locally applied statins as adjuncts to SRP in CP treatment, based on being an easy, low-cost alternative, with lesser adverse effects on bacterial resistance. These results should be interpreted with caution. Clinicians might consider the use of SRP + statins as an adjunct over other alternative approaches, based on the results of the present review. The informed decision should be taken, considering the patient's values and preferences, and the intervention to be implemented by the clinician.
Nankivil, Derek; Waterman, Gar; LaRocca, Francesco; Keller, Brenton; Kuo, Anthony N.; Izatt, Joseph A.
2015-01-01
We describe the first handheld, swept source optical coherence tomography (SSOCT) system capable of imaging both the anterior and posterior segments of the eye in rapid succession. A single 2D microelectromechanical systems (MEMS) scanner was utilized for both imaging modes, and the optical paths for each imaging mode were optimized for their respective application using a combination of commercial and custom optics. The system has a working distance of 26.1 mm and a measured axial resolution of 8 μm (in air). In posterior segment mode, the design has a lateral resolution of 9 μm, 7.4 mm imaging depth range (in air), 4.9 mm 6dB fall-off range (in air), and peak sensitivity of 103 dB over a 22° field of view (FOV). In anterior segment mode, the design has a lateral resolution of 24 μm, imaging depth range of 7.4 mm (in air), 6dB fall-off range of 4.5 mm (in air), depth-of-focus of 3.6 mm, and a peak sensitivity of 99 dB over a 17.5 mm FOV. In addition, the probe includes a wide-field iris imaging system to simplify alignment. A fold mirror assembly actuated by a bi-stable rotary solenoid was used to switch between anterior and posterior segment imaging modes, and a miniature motorized translation stage was used to adjust the objective lens position to correct for patient refraction between −12.6 and + 9.9 D. The entire probe weighs less than 630 g with a form factor of 20.3 x 9.5 x 8.8 cm. Healthy volunteers were imaged to illustrate imaging performance. PMID:26601014
Han, Ji-Young
2015-12-01
With the increasing prevalence of orthodontic treatment in adults, clear aligner treatments are becoming more popular. The aim of this study was to evaluate the effect of orthodontic treatment on periodontal tissue and to compare orthodontic treatment with fixed appliances (FA) to clear aligner treatment (CAT) in periodontitis patients. A total of 35 patients who underwent orthodontic treatment in the Department of Periodontology were included in this study. After periodontal treatment with meticulous oral hygiene education, patients underwent treatment with FA or CAT, and this study analyzed patient outcomes depending on the treatment strategy. Clinical parameters were assessed at baseline and after orthodontic treatment, and the duration of treatment was compared between these two groups. The overall plaque index, the gingival index, and probing depth improved after orthodontic treatment (P<0.01). The overall bone level also improved (P=0.045). However, the bone level changes in the FA and CAT groups were not significantly different. Significant differences were found between the FA and CAT groups in probing depth, change in probing depth, and duration of treatment (P<0.05). However, no significant differences were found between the FA and CAT groups regarding the plaque index, changes in the plaque index, the gingival index, changes in the gingival index, or changes in the alveolar bone level. The percentage of females in the CAT group (88%) was significantly greater than in the FA group (37%) (P<0.01). After orthodontic treatment, clinical parameters were improved in the FA and CAT groups with meticulous oral hygiene education and plaque control. Regarding plaque index and gingival index, no significant differences were found between these two groups. We suggest that combined periodontal and orthodontic treatment can improve patients' periodontal health irrespective of orthodontic techniques.
Shi, Meng; Wei, Yiping; Hu, Wenjie; Nie, Yong; Wu, Xiaolei; Lu, Ruifang
2018-01-01
Periodontitis is a kind of infectious disease initiated by colonization of subgingival periodontal pathogens, which cause destruction of tooth-supporting tissues, and is a predominant threat to oral health as the most common cause of loss of teeth. The aim of this pilot study was to characterize the subgingival bacterial biodiversity of periodontal pockets with different probing depths in patients with different forms of periodontitis. Twenty-one subgingival plaque samples were collected from three patients with chronic periodontitis (ChP), three patients with aggressive periodontitis (AgP) and three periodontally healthy subjects (PH). Each patient with periodontitis was sampled at three sites, at different probing depths (PDs, one each at 4 mm, 5-6 mm, and ≥ 7 mm). Using 16S rRNA gene high-throughput sequencing and bioinformatic analysis, we found that subgingival communities in health and periodontitis samples largely differed. Meanwhile, Acholeplasma, Fretibacterium, Porphyromonas, Peptococcus, Treponema_2, Defluviitaleaceae_UCG_011, Filifactor , and Mycoplasma increased with the deepening of the pockets in ChP, whilst only Corynebacterium was negatively associated with PD. In AgP, Corynebacterium and Klebsiella were positively associated with PD, while Serratia, Pseudoramibacter, Defluviitaleaceae_UCG_011 , and Desulfobulbus were negatively associated with PD. And among these two groups, Corynebacterium shifted differently. Moreover, in subgingival plaque, the unweighted UniFrac distances between samples from pockets with different PD in the same patients were significantly lower than those from pockets within the same PD category from different patients. This study demonstrated the shift of the subgingival microbiome in individual teeth sites during disease development. Within the limitation of the relative small sample size, this pilot study shed new light on the dynamic relationship between the extent of periodontal destruction and the subgingival microbiome.
Three-dimensional analysis of alveolar bone resorption by image processing of 3-D dental CT images
NASA Astrophysics Data System (ADS)
Nagao, Jiro; Kitasaka, Takayuki; Mori, Kensaku; Suenaga, Yasuhito; Yamada, Shohzoh; Naitoh, Munetaka
2006-03-01
We have developed a novel system that provides total support for assessment of alveolar bone resorption, caused by periodontitis, based on three-dimensional (3-D) dental CT images. In spite of the difficulty in perceiving the complex 3-D shape of resorption, dentists assessing resorption location and severity have been relying on two-dimensional radiography and probing, which merely provides one-dimensional information (depth) about resorption shape. However, there has been little work on assisting assessment of the disease by 3-D image processing and visualization techniques. This work provides quantitative evaluation results and figures for our system that measures the three-dimensional shape and spread of resorption. It has the following functions: (1) measures the depth of resorption by virtually simulating probing in the 3-D CT images, taking advantage of image processing of not suffering obstruction by teeth on the inter-proximal sides and much smaller measurement intervals than the conventional examination; (2) visualizes the disposition of the depth by movies and graphs; (3) produces a quantitative index and intuitive visual representation of the spread of resorption in the inter-radicular region in terms of area; and (4) calculates the volume of resorption as another severity index in the inter-radicular region and the region outside it. Experimental results in two cases of 3-D dental CT images and a comparison of the results with the clinical examination results and experts' measurements of the corresponding patients confirmed that the proposed system gives satisfying results, including 0.1 to 0.6mm of resorption measurement (probing) error and fairly intuitive presentation of measurement and calculation results.
Development of Compact, Modular Lunar Heat Flow Probes
NASA Technical Reports Server (NTRS)
Nagihara, S.; Zacny, K.; Hedlund, M.; Taylor, P. T.
2014-01-01
Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey and previously the International Lunar Network. Because the lander for such a mission will be relatively small, the heat flow instrumentation must be a low-mass and low-power system. The instrument needs to measure both thermal gradient and thermal conductivity of the regolith penetrated. It also needs to be capable of excavating a deep enough hole (approx. 3 m) to avoid the effect of potential long-term changes of the surface thermal environment. The recently developed pneumatic excavation system can largely meet the low-power, low-mass, and the depth requirements. The system utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. The thermal sensors consist of resistance temperature detectors (RTDs) embedded on the stem and an insitu thermal conductivity probe attached to the cone tip. The thermal conductivity probe consists of a short 'needle' (2.4-mm diam. and 15- to 20-mm length) that contains a platinum RTD wrapped in a coil of heater wire. During a deployment, when the penetrating cone reaches a desired depth, it stops blowing gas, and the stem pushes the needle into the yet-to-be excavated, undisturbed bottom soil. Then, it begins heating and monitors the temperature. Thermal conductivity of the soil can determined from the rate of temperature increase with time. When the measurement is complete, the system resumes excavation until it reaches the next targeted depth.
Wang, Qing-qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
Objective This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. Method A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Result Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Conclusion Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research. PMID:29049323
Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.
Local oxygen therapy for treating acute necrotizing periodontal disease in smokers.
Gaggl, Alexander J; Rainer, Heribert; Grund, Eveline; Chiari, Friedrich M
2006-01-01
The main aim of treatment for acute necrotizing periodontal disease is fast and effective reduction of anaerobic destructive microorganisms to avoid periodontal damage. The effect of adjunctive local oxygen therapy in the treatment of necrotizing periodontal disease was examined in this study. Thirty patients with acute necrotizing periodontal disease were treated with the systemic antibiotics amoxicillin, clavulanic acid, and metronidazole. In 15 out of 30 patients, adjunctive local oxygen therapy was administered. The patients were followed from the first to 10th day of treatment with clinical and bacteriological examinations. The clinical examination registered gingival bleeding, periodontal probing depth, and attachment loss; to follow up microbiological colonization of the periodontal sulcus, five representative bacteria were registered by a semiquantitative DNA polymerase chain reaction test. In both groups of patients, colonization with Prevotella intermedia, Tannerella forsythensis, and Treponema denticola was initially positive. None of these three microorganisms were completely eradicated in any of the patients in the group without oxygen therapy within the first 10 days of treatment. In the group with adjunctive oxygen therapy, all patients either showed a reduction in or complete eradication of the microorganisms, resulting in more rapid clinical restitution with less periodontal destruction. Adjunctive oxygen therapy results in early eradication of pathogenic anaerobic microorganisms in cases of acute necrotizing periodontal disease. The damage to periodontal tissue is reduced.
Rasperini, Giulio; Acunzo, Raffaele; Barnett, Andrew; Pagni, Giorgio
2013-01-01
The ability to stabilize the blood clot is crucial in achieving predictable periodontal regeneration in infrabony defects. Unfortunately, micromovements may cause degradation of the clot-root interface and result in suboptimal wound healing. Current surgical and suturing techniques are aimed at reducing flap micromovement because flap management is one of the main factors influencing the stability of the clot. The aim of this paper is to describe the use of the soft tissue wall technique to enhance periodontal tissue regeneration outcomes of challenging non-contained infrabony defects. Nine one-wall infrabony defects were treated with a combination of a papilla preservation technique and a coronally advanced flap. Enamel matrix derivative was delivered to the defect, but no bone grafting materials or membranes were employed. Mean 1-year probing depth reduction was 6.3 ± 2.0 mm (P < .001) and mean clinical attachment gain was 7.1 ± 1.0 mm (P < .001). All treated sites showed a mean reduction of exposed root surface equal to 1.0 ± 0.4 mm (P = .05). The results suggest the possibility of improving the regenerative potential of a one-wall infrabony defect by the creation of a stable soft tissue wall while also enhancing the esthetic outcome of the surgical procedure. Further studies with a larger number of patients are needed to support these preliminary data.
Makhlouf, Mona; Dahaba, Mushira M; Tunér, Jan; Eissa, Sohair A; Harhash, Tarek A-H
2012-03-01
The aim of this split-mouth, double blinded, short-term, controlled clinical trial was to study the effect of low-level laser therapy (LLLT) as an adjunct to scaling and root planing (SRP) for treatment of chronic periodontitis. LLLT is reported to improve the outcome of traditional SRP, but the evidence is still weak. Sixteen patients with a probing pocket depth (PPD) of 4-6 mm involving at least three teeth in each quadrant were recruited for the study. Afterwards, SRP quadrants were randomly assigned for 10 sessions of LLLT. Results showed that when compared to sites treated with SRP alone, those treated with SRP+LLLT (10 sessions, 830 nm, 100 mW, 3 J per point, 3 J/cm(2)) exhibited greater reductions in PPD at 5 weeks and 3 months but not at 6 months. Further, SRP+LLLT-treated sites had a statistically significant increase in mean radiographic bone density when comparing 6- and 12-month data and overall from baseline to 12 months. There was a trend to reduce interleukin (IL)-1β but the difference between control and laser sites was not statistically significant. SRP combined with LLLT improved radiographic bone density and short-term PPD reduction in patients with chronic periodontitis, but did not significantly affect either the gingival crevicular fluid of IL-1β or the gingival or plaque index.
Titan probe technology assessment and technology development plan study
NASA Technical Reports Server (NTRS)
Castro, A. J.
1980-01-01
The need for technology advances to accomplish the Titan probe mission was determined by defining mission conditions and requirements and evaluating the technology impact on the baseline probe configuration. Mission characteristics found to be technology drivers include (1) ten years dormant life in space vacuum; (2) unknown surface conditions, various sample materials, and a surface temperature; and (3) mission constraints of the Saturn Orbiter Dual Probe mission regarding weight allocation. The following areas were identified for further development: surface sample acquisition system; battery powered system; nonmetallic materials; magnetic bubble memory devices, and the landing system. Preentry science, reliability, and weight reduction and redundancy must also be considered.
NASA Astrophysics Data System (ADS)
Zhang, Changyu; Wang, Runyu; Cheng, Longhuai; Li, Bingjie; Xi, Zhen; Yi, Long
2016-07-01
Hydrogen sulfide (H2S) is an important signalling molecule with multiple biological functions. The reported H2S fluorescent probes are majorly based on redox or nucleophilic reactions. The combination usage of both redox and nucleophilic reactions could improve the probe’s selectivity, sensitivity and stability. Herein we report a new dual-reactable probe with yellow turn-on fluorescence for H2S detection. The sensing mechanism of the dual-reactable probe was based on thiolysis of NBD (7-nitro-1,2,3-benzoxadiazole) amine (a nucleophilic reaction) and reduction of azide to amine (a redox reaction). Compared with its corresponding single-reactable probes, the dual-reactable probe has higher selectivity and fluorescence turn-on fold with magnitude of multiplication from that of each single-reactable probe. The highly selective and sensitive properties enabled the dual-reactable probe as a useful tool for efficiently sensing H2S in aqueous buffer and in living cells.
Pouw, Bas; de Wit-van der Veen, Linda J; van Duijnhoven, Frederieke; Rutgers, Emiel J Th; Stokkel, Marcel P M; Valdés Olmos, Renato A; Vrancken Peeters, Marie-Jeanne T F D
2016-05-01
Mammographic screening has led to the identification of more women with nonpalpable breast cancer, many of them to be treated with breast-preserving surgery. To accomplish radical tumor excision, adequate localization techniques such as radioactive seed localization (RSL) are required. For RSL, a radioactive I-seed is implanted central in the tumor to enable intraoperative localization using a γ-probe. In case of extensive tumor or multifocal carcinoma, multiple I-seeds can be used to delineate the involved area. Preoperative imaging is performed different from surgical positioning; therefore, exact I-seed depth remains unknown during surgery. Twenty patients (mean age, 56.8 years) with 25 implanted I-seeds scheduled for RSL were included. Sixteen patients had 1 I-seed implanted in the primary lesion, 3 patients had 2 I-seeds, and 1 patient had 3 I-seeds. Freehand SPECT localized I-seeds by measuring γ-counts from different directions, all registered by an optical tracking system. A reconstruction and visualization algorithm enabled 3-dimensional (3D) navigation toward the I-seeds. Freehand SPECT visualized all I-seeds in primary tumors and provided preincision depth information. The deviation, mean (SD), between the freehand SPECT depth and the surgical depth estimation was 1.9 (2.1) mm (range, 0-7 mm). Three-dimensional freehand SPECT was especially useful identifying multiple implanted I-seeds because the conventional γ-probe has more difficulty discriminating I-seeds transcutaneous. Freehand SPECT with 3D navigation is a valuable tool in RSL for both single and multiple implanted I-seeds in breast-preserving cancer surgery. Freehand SPECT provides continuous updating 3D imaging with information about depth and location of the I-seeds contributing to adequate excision of nonpalpable breast cancer.
Quantum simulation in strongly correlated optical lattices
NASA Astrophysics Data System (ADS)
Mckay, David C.
My work on the 87Rb apparatus focuses on three main topics: simulating the Bose-Hubbard (BH) model out of equilibrium, developing thermometry probes, and developing impurity probes using a 3D spin-dependent lattice. Theoretical techniques (e.g., QMC) are adept at describing the equilibrium properties of the BH model, but the dynamics are unknown --- simulation is able to bridge this gap. We perform two experiments to simulate the BH model out of equilibrium. In the first experiment, published in Ref. [1], we measure the decay rate of the center-of-mass velocity for a Bose-Einstein condensate trapped in a cubic lattice. We explore this dissipation for different Bose-Hubbard parameters (corresponding to different lattice depths) and temperatures. We observe a decay rate that asymptotes to a finite value at zero temperature, which we interpret as evidence of intrinsic decay due to quantum tunneling of phase slips. The decay rate exponentially increases with temperature, which is consistent with a cross-over from quantum tunneling to thermal activation. While phase slips are a well-known dissipation mechanism in superconductors, numerous effects prevent unambiguous detection of quantum phase slips. Therefore, our measurement is among the strongest evidence for quantum tunneling of phase slips. In a second experiment, published in Ref. [2] with theory collaborators at Cornell University, we investigate condensate fraction evolution during fast (i.e., millisecond) ramps of the lattice potential depth. These ramps simulate the BH model with time-dependent parameters. We determine that interactions lead to significant condensate fraction redistribution during these ramps, in agreement with mean-field calculations. This result clarifies adiabatic timescales for the lattice gas and strongly constrains bandmapping as an equilibrium probe. Another part of this thesis work involves developing thermometry techniques for the lattice gas. These techniques are important because the ability to measure temperature is required for quantum simulation and to evaluate in-lattice cooling schemes. In work published in Ref. [3], we explore measuring temperature by directly fitting the quasimomentum distribution of a thermal lattice gas. We attempt to obtain quasimomentum distributions by bandmapping, a process in which the lattice depth is reduced slowly compared to the bandgap but fast with respect to all other timescales. We find that these temperature measurements fail when the thermal energy is comparable to the bandwidth of the lattice. This failure results from two main causes. First, the quasimomentum distribution is an insensitive probe at high temperatures because the band is occupied (i.e., additional thermal energy cannot be accommodated in the kinetic energy degrees of freedom). Second, the bandmapping process does not produce accurate quasimomentum distributions because of smoothing at the Brillouin zone edge. We determine that measuring temperature using the in-situ width overcomes these issues. The in-situ width does not asymptote to a finite value as temperature increases, and the in-situ width can be measured directly without using a mapping procedure. In a second experiment, we investigate using condensate fraction (obtained from the time-of-flight momentum distribution) as an indirect means to measure temperature in the superfluid regime of the BH model. Since no standard fitting procedure exists for the lattice time-of-flight distributions, we define and test a procedure as part of this work. We measure condensate fraction for a range of lattice depths varying from deep in the superfluid regime to lattice depths proximate to the Mott-insulator transition. We also vary the entropy per particle, which is measured in the harmonic trap before adiabatically loading into the lattice. As expected, the condensate fraction increases as entropy decreases, and the condensate fraction decreases at high lattice depths (due to quantum depletion). We compare our experimental results to condensate fraction predicted by the non-interacting, Hartree-Fock-Bogoliubov-Popov, and site-decoupled-mean-field theories. Theory and experiment disagree, which motivates several future extensions to this work, including calculating condensate fraction (and testing our fit procedure) using quantum Monte Carlo numerics, and experimentally and theoretically investigating the dynamics of the lattice load process (for the finite-temperature strongly correlated regime). Finally, we develop impurity probes for the Bose-Hubbard model by employing a spin-dependent lattice. A primary accomplishment of this thesis work was to develop the first 3D spin-dependent lattice in the strongly correlated regime (published in Ref. [4]). The spin-dependent lattice depth is proportional to |gFmF|, enabling the creation of mixtures of atoms trapped in the lattice (nonzero mF) co-trapped with atoms that do not experience the lattice (mF≠ 0). We use the non-lattice atoms as an impurity probe. We investigate using the impurity to probe the lattice temperature, and we determine that thermalization between the impurity and lattice gas is suppressed for larger lattice depths. Using a comparison to a Fermi's golden rule calculation of the collisional energy exchange rate, we determine that this effect is consistent with suppression of energy-exchanging collisions by a mismatch between the impurity and lattice gas dispersion. While this result invalidates the concept of an impurity thermometer, it paves the way for a unique cooling scheme that relies on inter-species thermal isolation. We also explore impurity transport through the lattice gas. In other preliminary measurements, we also identify the decay rate of the center-of-mass motion as a prospective impurity probe.
A brushless dc spin motor for momentum exchange altitude control
NASA Technical Reports Server (NTRS)
Stern, D.; Rosenlieb, J. W.
1972-01-01
Brushless dc spin motor is designed to use Hall effect probes as means of revolving rotor position and controlling motor winding currents. This results in 3 to 1 reduction in watt-hours required for wheel acceleration, a 2 to 1 reduction in power to run wheel, and a 10 to 1 reduction in the electronics size and weight.
Simulation of Fluid Flow and Collection Efficiency for an SEA Multi-element Probe
NASA Technical Reports Server (NTRS)
Rigby, David L.; Struk, Peter M.; Bidwell, Colin
2014-01-01
Numerical simulations of fluid flow and collection efficiency for a Science Engineering Associates (SEA) multi-element probe are presented. Simulation of the flow field was produced using the Glenn-HT Navier-Stokes solver. Three-dimensional unsteady results were produced and then time averaged for the heat transfer and collection efficiency results. Three grid densities were investigated to enable an assessment of grid dependence. Simulations were completed for free stream velocities ranging from 85-135 meters per second, and free stream total pressure of 44.8 and 93.1 kilopascals (6.5 and 13.5 pounds per square inch absolute). In addition, the effect of angle of attack and yaw were investigated by including 5 degree deviations from straight for one of the flow conditions. All but one of the cases simulated a probe in isolation (i.e. in a very large domain without any support strut). One case is included which represents a probe mounted on a support strut within a finite sized wind tunnel. Collection efficiencies were generated, using the LEWICE3D code, for four spherical particle sizes, 100, 50, 20, and 5 micron in diameter. It was observed that a reduction in velocity of about 20% occurred, for all cases, as the flow entered the shroud of the probe. The reduction in velocity within the shroud is not indicative of any error in the probe measurement accuracy. Heat transfer results are presented which agree quite well with a correlation for the circular cross section heated elements. Collection efficiency results indicate a reduction in collection efficiency as particle size is reduced. The reduction with particle size is expected, however, the results tended to be lower than the previous results generated for isolated two-dimensional elements. The deviation from the two-dimensional results is more pronounced for the smaller particles and is likely due to the reduced flow within the protective shroud. As particle size increases differences between the two-dimensional and three dimensional results become negligible. Taken as a group, the total collection efficiency of the elements including the effects of the shroud has been shown to be in the range of 0.93 to 0.99 for particles above 20 microns. The 3D model has improved the estimated collection efficiency for smaller particles where errors in previous estimates were more significant.
NASA Astrophysics Data System (ADS)
Wakimoto, Tatsuro; Araga, Koichi; Katoh, Kenji
2018-03-01
As widely known, the addition of a specific type of surfactant to water reduces drag in a pipe flow. This effect is considered to be a result of the suppression of turbulent transition caused by the ordered structure of rod-like micelles that is referred to as a shear-induced structure (SIS). However, it is typically difficult to determine the SIS since it is necessary to noninvasively detect the SIS with several hundred nanometers in the actual moving flow. In this study, we used the fluorescence probe method to locally determine the SIS in a pipe flow. When hydrophobic fluorescence molecules are added to the surfactant solution, the fluorescence molecules are trapped in micelles. Thus, fluorescence intensity varies based on the change in the micellar structure. We verified the applicability of the fluorescence probe method to the SIS detection and determined the relationship between the micellar structure and the drag reduction in the pipe flow by simultaneously measuring the fluorescence intensity and pipe friction factor. The experimental result demonstrates that the SIS formation in the near-wall region is closely correlated with the drag reduction and suggests that the near-wall SIS suppresses the turbulent transition.
Refinement of planetary protection policy for Mars missions
NASA Technical Reports Server (NTRS)
DeVincenzi, D. L.; Stabekis, P.; Barengoltz, J.
1996-01-01
Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields. In 1992, a U.S. National Research Council study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre-sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV and its planetary protection requirements be divided into two sub-categories as follows: Category IVa, for missions comprising landers and probes without life detection experiments, which will meet a specified bioburden limit for exposed surfaces, and Category IVb, for landers and probes with life detection experiments, which will require sterilization of landed systems. In addition, Category III orbiter mission specifications are expanded to be consistent with these recommendations.
NASA Technical Reports Server (NTRS)
Barrett, K.; Kasischke, E. S.; McGuire, A. D.; Turetsky, M. R.; Kane, E. S.
2010-01-01
Biomass burning in the Alaskan interior is already a major disturbance and source of carbon emissions, and is likely to increase in response to the warming and drying predicted for the future climate. In addition to quantifying changes to the spatial and temporal patterns of burned areas, observing variations in severity is the key to studying the impact of changes to the fire regime on carbon cycling, energy budgets, and post-fire succession. Remote sensing indices of fire severity have not consistently been well-correlated with in situ observations of important severity characteristics in Alaskan black spruce stands, including depth of burning of the surface organic layer. The incorporation of ancillary data such as in situ observations and GIS layers with spectral data from Landsat TM/ETM+ greatly improved efforts to map the reduction of the organic layer in burned black spruce stands. Using a regression tree approach, the R2 of the organic layer depth reduction models was 0.60 and 0.55 (pb0.01) for relative and absolute depth reduction, respectively. All of the independent variables used by the regression tree to estimate burn depth can be obtained independently of field observations. Implementation of a gradient boosting algorithm improved the R2 to 0.80 and 0.79 (pb0.01) for absolute and relative organic layer depth reduction, respectively. Independent variables used in the regression tree model of burn depth included topographic position, remote sensing indices related to soil and vegetation characteristics, timing of the fire event, and meteorological data. Post-fire organic layer depth characteristics are determined for a large (N200,000 ha) fire to identify areas that are potentially vulnerable to a shift in post-fire succession. This application showed that 12% of this fire event experienced fire severe enough to support a change in post-fire succession. We conclude that non-parametric models and ancillary data are useful in the modeling of the surface organic layer fire depth. Because quantitative differences in post-fire surface characteristics do not directly influence spectral properties, these modeling techniques provide better information than the use of remote sensing data alone.
Barrett, Kirsten M.; Kasischke, E.S.; McGuire, A.D.; Turetsky, M.R.; Kane, E.S.
2010-01-01
Biomass burning in the Alaskan interior is already a major disturbance and source of carbon emissions, and is likely to increase in response to the warming and drying predicted for the future climate. In addition to quantifying changes to the spatial and temporal patterns of burned areas, observing variations in severity is the key to studying the impact of changes to the fire regime on carbon cycling, energy budgets, and post-fire succession. Remote sensing indices of fire severity have not consistently been well-correlated with in situ observations of important severity characteristics in Alaskan black spruce stands, including depth of burning of the surface organic layer. The incorporation of ancillary data such as in situ observations and GIS layers with spectral data from Landsat TM/ETM+ greatly improved efforts to map the reduction of the organic layer in burned black spruce stands. Using a regression tree approach, the R2 of the organic layer depth reduction models was 0.60 and 0.55 (pb0.01) for relative and absolute depth reduction, respectively. All of the independent variables used by the regression tree to estimate burn depth can be obtained independently of field observations. Implementation of a gradient boosting algorithm improved the R2 to 0.80 and 0.79 (pb0.01) for absolute and relative organic layer depth reduction, respectively. Independent variables used in the regression tree model of burn depth included topographic position, remote sensing indices related to soil and vegetation characteristics, timing of the fire event, and meteorological data. Post-fire organic layer depth characteristics are determined for a large (N200,000 ha) fire to identify areas that are potentially vulnerable to a shift in post-fire succession. This application showed that 12% of this fire event experienced fire severe enough to support a change in post-fire succession. We conclude that non-parametric models and ancillary data are useful in the modeling of the surface organic layer fire depth. Because quantitative differences in post-fire surface characteristics do not directly influence spectral properties, these modeling techniques provide better information than the use of remote sensing data alone.
In-plane ultrasonic needle tracking using a fiber-optic hydrophone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial
Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less
Belzile, Mei-Ni; Godin, Robert; Durantini, Andrés M; Cosa, Gonzalo
2016-12-21
We report herein the design, synthesis, and characterization of a two-segment fluorogenic analogue of vitamin K, B-VK Q , prepared by coupling vitamin K 3 , also known as menadione (a quinone redox center), to a boron-dipyrromethene (BODIPY) fluorophore (a lipophilic reporter segment). Oxidation-reduction reactions, spectroelectrochemical studies, and enzymatic assays conducted in the presence of DT-diaphorase illustrate that the new probe shows reversible redox behavior on par with that of vitamin K, provides a high-sensitivity fluorescence signal, and is compatible with biological conditions, opening the door to monitor remotely (i.e., via imaging) redox processes in real time. In its oxidized form, B-VK Q is non-emissive, while upon reduction to the hydroquinone form, B-VK QH 2 , BODIPY fluorescence is restored, with emission quantum yield values of ca. 0.54 in toluene. Density functional theory studies validate a photoinduced electron transfer intramolecular switching mechanism, active in the non-emissive quinone form and deactivated upon reduction to the emissive dihydroquinone form. Our results highlight the potential of B-VK Q as a fluorogenic probe to study electron transfer and transport in model systems and biological structures with optimal sensitivity and desirable chemical specificity. Use of such a probe may enable a better understanding of the role that vitamin K plays in biological redox reactions ubiquitous in key cellular processes, and help elucidate the mechanism and pathological significance of these reactions in biological systems.
Opto-Electronic Characterization CdTe Solar Cells from TCO to Back Contact with Nano-Scale CL Probe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moseley, John; Al-Jassim, Mowafak M.; Paudel, Naba
2015-06-14
We used cathodoluminescence (CL) (spectrum-per-pixel) imaging on beveled CdTe solar cell sections to investigate the opto-electronic properties of these devices from the TCO to the back contact. We used a nano-scale CL probe to resolve luminescence from grain boundary (GB) and grain interior (GI) locations near the CdS/CdTe interface where the grains are very small. As-deposited, CdCl2-treated, Cu-treated, and (CdCl2+Cu)-treated cells were analyzed. Color-coded CL spectrum imaging maps on bevels illustrate the distribution of the T=6 K luminescence transitions through the depth of devices with unprecedented spatial resolution. The CL at the GBs and GIs is shown to vary significantlymore » from the front to the back of devices and is a sensitive function of processing. Supporting D-SIMS depth profile, TRPL lifetime, and C-V measurements are used to link the CL data to the J-V performance of devices.« less
Infrared fiber optic probes for evaluation of musculoskeletal tissue pathology
NASA Astrophysics Data System (ADS)
Padalkar, Mugdha; McGoverin, Cushla; Onigbanjo, Quam; Spencer, Richard; Barbash, Scott; Kropf, Eric; Pleshko, Nancy
2014-03-01
Musculoskeletal pathology of the knee commonly occurs with aging and as a result of injury. The incidence of anterior cruciate ligament (ACL) injuries continues to increase annually, and may precede the eventual onset of osteoarthritis (OA), a debilitating and prevalent disease characterized by cartilage degeneration. Early detection of OA remains elusive, with current imaging methods lacking adequate sensitivity to detect early pathologic cartilage changes. We used mid- and near- infrared (IR) spectroscopy through arthroscopic-based fiber-optic devices to assess cartilage damage and differentiate tendon from ligament. Mid-IR spectroscopy is characterized by distinct bands and low penetration depth (< 10 μm) and near-IR spectroscopy is characterized by complex overlapping bands and greater penetration depths (< 1 cm). We have found that combined mid- and near-IR analysis greatly extends the information available through either in the analysis of soft tissues, including cartilage, ligaments and tendons. We discuss here basic science studies and the potential for translation to clinical research with novel arthroscopic probes.
The effect of high energy ion beam analysis on D trapping in W
NASA Astrophysics Data System (ADS)
Finlay, T. J.; Davis, J. W.; Schwarz-Selinger, T.; Haasz, A. A.
2017-12-01
High energy ion beam analyses (IBA) are invaluable for measuring concentration depth profiles of light elements in solid materials, and important in the study of fusion fuel retention in tokamaks. Polycrystalline W specimens were implanted at 300 and 500 K, 5-10 × 1023 D m-2 fluence, with deuterium-only and simultaneous D-3%He ion beams. Selected specimens were analysed by elastic recoil detection analysis (ERDA) and/or nuclear reaction analysis (NRA). All specimens were measured by thermal desorption spectroscopy (TDS). The D TDS spectra show an extra peak at 900-1000 K following ERDA and/or NRA measurements. The peak height appears to correlate with the amount of D initially trapped beyond the calculated IBA probe beam peak damage depth. Similar to pre-implantation damage scenarios, the IBA probe beam creates empty high energy traps which later retrap D atoms during TDS heating, which is supported by modelling experimental results using the Tritium Migration Analysis Program.
Three-Dimensional Optical Coherence Tomography
NASA Technical Reports Server (NTRS)
Gutin, Mikhail; Wang, Xu-Ming; Gutin, Olga
2009-01-01
Three-dimensional (3D) optical coherence tomography (OCT) is an advanced method of noninvasive infrared imaging of tissues in depth. Heretofore, commercial OCT systems for 3D imaging have been designed principally for external ophthalmological examination. As explained below, such systems have been based on a one-dimensional OCT principle, and in the operation of such a system, 3D imaging is accomplished partly by means of a combination of electronic scanning along the optical (Z) axis and mechanical scanning along the two axes (X and Y) orthogonal to the optical axis. In 3D OCT, 3D imaging involves a form of electronic scanning (without mechanical scanning) along all three axes. Consequently, the need for mechanical adjustment is minimal and the mechanism used to position the OCT probe can be correspondingly more compact. A 3D OCT system also includes a probe of improved design and utilizes advanced signal- processing techniques. Improvements in performance over prior OCT systems include finer resolution, greater speed, and greater depth of field.
Quaranta, Alessandro; Lim, Zhuo Wei; Tang, Joyce; Perrotti, Vittoria; Leichter, Jonathan
2017-06-01
To perform a systematic review on the impact of residual subgingival cement on peri-implant diseases and crestal bone loss. MEDLINE, SCOPUS, ISI Web of Knowledge and Cochrane Central Register of Controlled Trials (CENTRAL) databases were used to identify articles published without time limits. A total of 6 articles were selected for a total of 389 patients (687 implants). The studies were heterogeneous and had a moderate-to-high risk of bias, but met the inclusion criteria. Four of 6 studies were published by the same research group and assessed similar populations over time. A positive relationship between residual cement and peri-implant inflammation was observed. Data on peri-implant probing depths and crestal bone loss were reported in 1 study. Residual subgingival cement seems to be strongly associated with peri-implant mucositis which is a risk factor for increased probing depths crestal bone loss and peri-implantitis. Zinc oxide eugenol cements should be preferred to resin cements especially in patients with a history of periodontitis.
Consensus Conference Findings on Supragingival and Subgingival Air Polishing.
Cobb, Charles M; Daubert, Diane M; Davis, Karen; Deming, Jodi; Flemmig, Thomas F; Pattison, Anna; Roulet, Jean-François; Stambaugh, Roger V
2017-02-01
A consensus conference was convened to evaluate and address issues of safety and efficacy when using glycine powder in an air-powder jet device for supra- and subgingival applications during dental prophylaxis and periodontal maintenance. The conference reported the following conclusions: 1) Supra- and subgingival air polishing using glycine powder is safe and effective for removal of biofilms from natural tooth structure and restorative materials; 2) there is no evidence of soft-tissue abrasion when using glycine powder in an air-polishing device; 3) in periodontal probing depths of 1 mm to 4 mm, glycine-powder air polishing, using a standard air-polishing nozzle, is more effective at removing subgingival biofilm than manual or ultrasonic instruments; and 4) at probing depths of 5 mm to 9 mm, using a subgingival nozzle, glycine powder air polishing is more effective at removing subgingival biofilm than manual or ultrasonic instrumentation. This conference statement, supported by an industry grant, was drafted by a panel of distinguished dental professionals.