Schematic displays for the Space Shuttle Orbiter multifunction cathode-ray-tube display system
NASA Technical Reports Server (NTRS)
Weiss, W.
1979-01-01
A standardized procedure for developing cathode ray tube displayed schematic diagrams. The displaying of Spacelab information on the space shuttle orbiter multifunction cathode ray tube display system is used to illustrate this procedure. Schematic displays with the equivalent tabular displays are compared.
Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan
2017-08-01
In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.
System status display evaluation
NASA Technical Reports Server (NTRS)
Summers, Leland G.
1988-01-01
The System Status Display is an electronic display system which provides the crew with an enhanced capability for monitoring and managing the aircraft systems. A flight simulation in a fixed base cockpit simulator was used to evaluate alternative design concepts for this display system. The alternative concepts included pictorial versus alphanumeric text formats, multifunction versus dedicated controls, and integration of the procedures with the system status information versus paper checklists. Twelve pilots manually flew approach patterns with the different concepts. System malfunctions occurred which required the pilots to respond to the alert by reconfiguring the system. The pictorial display, the multifunction control interfaces collocated with the system display, and the procedures integrated with the status information all had shorter event processing times and lower subjective workloads.
NASA Technical Reports Server (NTRS)
Runnels, R. L.
1973-01-01
The standards and procedures for the generation of operational display formats to be used in the Mission Control Center (MCC) display control system are presented. The required effort, forms, and fundamentals for the design, specifications, and production of display formats are identified. The principles of display design and system constraints controlling the creation of optimum operational displays for mission control are explained. The basic two types of MCC display systems for presenting information are described.
Research in Natural Language Understanding
1979-08-31
REFERENCES 159 APPENDIX A 1 A. 2 A. 3 A. 4 A. 5 A. PLAN-RELATED INFERENCE PROCEDURES ACTION -topian: ACTION -toplanrecog: S-REQUEST-INFORMlF...speech acts and attached procedures> The system’s model of its display actions . Taxonomy of display actions . The display scope after sentence 3...34. At various points the system is in a state where it needs to determine which of a large number of possible rules of action are applicable to its
Satellite freeze forecast system. Operating/troubleshooting manual
NASA Technical Reports Server (NTRS)
Martsolf, J. D. (Principal Investigator)
1983-01-01
Examples of operational procedures are given to assist users of the satellites freeze forecasting system (SFFS) in logging in on to the computer, executing the programs in the menu, logging off the computer, and setting up the automatic system. Directions are also given for displaying, acquiring, and listing satellite maps; for communicating via terminal and monitor displays; and for what to do when the SFFS doesn't work. Administrative procedures are included.
NASA Technical Reports Server (NTRS)
Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.
1992-01-01
This document describes the software created for the Sperry Microprocessor Color Display System used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global reference section includes procedures and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight cathode ray tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.
AMPS data management concepts. [Atmospheric, Magnetospheric and Plasma in Space experiment
NASA Technical Reports Server (NTRS)
Metzelaar, P. N.
1975-01-01
Five typical AMPS experiments were formulated to allow simulation studies to verify data management concepts. Design studies were conducted to analyze these experiments in terms of the applicable procedures, data processing and displaying functions. Design concepts for AMPS data management system are presented which permit both automatic repetitive measurement sequences and experimenter-controlled step-by-step procedures. Extensive use is made of a cathode ray tube display, the experimenters' alphanumeric keyboard, and the computer. The types of computer software required by the system and the possible choices of control and display procedures available to the experimenter are described for several examples. An electromagnetic wave transmission experiment illustrates the methods used to analyze data processing requirements.
WISP information display system user's manual
NASA Technical Reports Server (NTRS)
Alley, P. L.; Smith, G. R.
1978-01-01
The wind shears program (WISP) supports the collection of data on magnetic tape for permanent storage or analysis. The document structure provides: (1) the hardware and software configuration required to execute the WISP system and start up procedure from a power down condition; (2) data collection task, calculations performed on the incoming data, and a description of the magnetic tape format; (3) the data display task and examples of displays obtained from execution of the real time simulation program; and (4) the raw data dump task and examples of operator actions required to obtained the desired format. The procedures outlines herein will allow continuous data collection at the expense of real time visual displays.
An automatic calibration procedure for remote eye-gaze tracking systems.
Model, Dmitri; Guestrin, Elias D; Eizenman, Moshe
2009-01-01
Remote gaze estimation systems use calibration procedures to estimate subject-specific parameters that are needed for the calculation of the point-of-gaze. In these procedures, subjects are required to fixate on a specific point or points at specific time instances. Advanced remote gaze estimation systems can estimate the optical axis of the eye without any personal calibration procedure, but use a single calibration point to estimate the angle between the optical axis and the visual axis (line-of-sight). This paper presents a novel automatic calibration procedure that does not require active user participation. To estimate the angles between the optical and visual axes of each eye, this procedure minimizes the distance between the intersections of the visual axes of the left and right eyes with the surface of a display while subjects look naturally at the display (e.g., watching a video clip). Simulation results demonstrate that the performance of the algorithm improves as the range of viewing angles increases. For a subject sitting 75 cm in front of an 80 cm x 60 cm display (40" TV) the standard deviation of the error in the estimation of the angles between the optical and visual axes is 0.5 degrees.
Displaying Colors of Specified Chrominance on a Color Graphics Display.
1982-12-01
coordinates (such as Commission Internationale de l’Eclairage CIEXYZ coordinates). This report contains the description of a procedure for displaying...colors of known chrominance as specified by CIEXYZ coordinates. The procedure makes use of models of a color graphics system intensity (bits) to lumi...coordinates (e.g., CIELUV -1976 CT contrast equations as described in Robertson, 1977). Thus, the results of most efforts to specify a set of colors to
Vision based flight procedure stereo display system
NASA Astrophysics Data System (ADS)
Shen, Xiaoyun; Wan, Di; Ma, Lan; He, Yuncheng
2008-03-01
A virtual reality flight procedure vision system is introduced in this paper. The digital flight map database is established based on the Geographic Information System (GIS) and high definitions satellite remote sensing photos. The flight approaching area database is established through computer 3D modeling system and GIS. The area texture is generated from the remote sensing photos and aerial photographs in various level of detail. According to the flight approaching procedure, the flight navigation information is linked to the database. The flight approaching area vision can be dynamic displayed according to the designed flight procedure. The flight approaching area images are rendered in 2 channels, one for left eye images and the others for right eye images. Through the polarized stereoscopic projection system, the pilots and aircrew can get the vivid 3D vision of the flight destination approaching area. Take the use of this system in pilots preflight preparation procedure, the aircrew can get more vivid information along the flight destination approaching area. This system can improve the aviator's self-confidence before he carries out the flight mission, accordingly, the flight safety is improved. This system is also useful in validate the visual flight procedure design, and it helps to the flight procedure design.
Screwworm Eradication Data System (SEDS) operational manual, part 3
NASA Technical Reports Server (NTRS)
1976-01-01
All phases of SEDS operation as well as utility routines, error messages, and system disk maintenance procedures are described. Display layouts and examples of runs are included as additional explanation to SEDS program procedures.
Usability Study of Two Collocated Prototype System Displays
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
2007-01-01
Currently, most of the displays in control rooms can be categorized as status screens, alerts/procedures screens (or paper), or control screens (where the state of a component is changed by the operator). The primary focus of this line of research is to determine which pieces of information (status, alerts/procedures, and control) should be collocated. Two collocated displays were tested for ease of understanding in an automated desktop survey. This usability study was conducted as a prelude to a larger human-in-the-loop experiment in order to verify that the 2 new collocated displays were easy to learn and usable. The results indicate that while the DC display was preferred and yielded better performance than the MDO display, both collocated displays can be easily learned and used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sebok, A.; Nystad, E.
This paper describes a study investigating questions of learning effectiveness in different VR technology types. Four VR display technology types were compared in terms of their ability to support procedural learning. The VR systems included two desktop displays (mono-scopic and stereoscopic view), a large screen stereoscopic display, and a mono-scopic head-mounted display. Twenty-four participants completed procedural training scenarios on these different display types. Training effectiveness was assessed in terms of objective task performance. Following the training session, participants performed the procedure they had just learned using the same VR display type they used for training. Time to complete the proceduremore » and errors were recorded. Retention and transfer of training were evaluated in a talk-through session 24 hours after the training. In addition, subjective questionnaire data were gathered to investigate perceived workload, Sense of Presence, simulator sickness, perceived usability, and ease of navigation. While no difference was found for the short-term learning, the study results indicate that retention and transfer of training were better supported by the large screen stereoscopic condition. (authors)« less
Application of a minicomputer-based system in measuring intraocular fluid dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bronzino, J.D.; D'Amato, D.P.; O'Rourke, J.
A complete, computerized system has been developed to automate and display radionuclide clearance studies in an ophthalmology clinical laboratory. The system is based on a PDP-8E computer with a 16-k core memory and includes a dual-drive Decassette system and an interactive display terminal. The software controls the acquisition of data from an NIM scaler, times the procedures, and analyzes and simultaneously displays logarithmically converted data on a fully annotated graph. Animal studies and clinical experiments are presented to illustrate the nature of these displays and the results obtained using this automated eye physiometer.
Management and display of four-dimensional environmental data sets using McIDAS
NASA Technical Reports Server (NTRS)
Hibbard, William L.; Santek, David; Suomi, Verner E.
1990-01-01
Over the past four years, great strides have been made in the areas of data management and display of 4-D meteorological data sets. A survey was conducted of available and planned 4-D meteorological data sources. The data types were evaluated for their impact on the data management and display system. The requirements were analyzed for data base management generated by the 4-D data display system. The suitability of the existing data base management procedures and file structure were evaluated in light of the new requirements. Where needed, new data base management tools and file procedures were designed and implemented. The quality of the basic 4-D data sets was assured. The interpolation and extrapolation techniques of the 4-D data were investigated. The 4-D data from various sources were combined to make a uniform and consistent data set for display purposes. Data display software was designed to create abstract line graphic 3-D displays. Realistic shaded 3-D displays were created. Animation routines for these displays were developed in order to produce a dynamic 4-D presentation. A prototype dynamic color stereo workstation was implemented. A computer functional design specification was produced based on interactive studies and user feedback.
Pins and posters: Paradigms for content publication on situated displays.
José, Rui; Pinto, Hélder; Silva, Bruno; Melro, Ana
2013-01-01
Public-display systems are still far from being a medium for meeting people's diverse communication goals. Moving toward open displays will require publication paradigms that can overcome the challenges of meaningful engagement and enable users to fully understand and control the publication process. The metaphors of pins and posters have inspired two complementary paradigms for public displays. Researchers implemented these paradigms in the Instant Places system, which they deployed on 10 displays in diverse urban locations for six months. They collected user and system data regarding the users' practices. The findings improve the understanding of what might drive user-generated content in networks of urban displays. Such knowledge can inform the design of tools and procedures for situated publication in public displays.
Experiments using electronic display information in the NASA terminal configured vehicle
NASA Technical Reports Server (NTRS)
Morello, S. A.
1980-01-01
The results of research experiments concerning pilot display information requirements and visualization techniques for electronic display systems are presented. Topics deal with display related piloting tasks in flight controls for approach-to-landing, flight management for the descent from cruise, and flight operational procedures considering the display of surrounding air traffic. Planned research of advanced integrated display formats for primary flight control throughout the various phases of flight is also discussed.
NASA Technical Reports Server (NTRS)
Montoya, R. J.; England, J. N.; Hatfield, J. J.; Rajala, S. A.
1981-01-01
The hardware configuration, software organization, and applications software for the NASA IKONAS color graphics display system are described. The systems were created at the Langley Research Center Display Device Laboratory to develop, evaluate, and demonstrate advanced generic concepts, technology, and systems integration techniques for electronic crew station systems of future civil aircraft. A minicomputer with 64K core memory acts as a host for a raster scan graphics display generator. The architectures of the hardware system and the graphics display system are provided. The applications software features a FORTRAN-based model of an aircraft, a display system, and the utility program for real-time communications. The model accepts inputs from a two-dimensional joystick and outputs a set of aircraft states. Ongoing and planned work for image segmentation/generation, specialized graphics procedures, and higher level language user interface are discussed.
Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa
2014-12-01
The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.
[Display technologies for augmented reality in medical applications].
Eck, Ulrich; Winkler, Alexander
2018-04-01
One of the main challenges for modern surgery is the effective use of the many available imaging modalities and diagnostic methods. Augmented reality systems can be used in the future to blend patient and planning information into the view of surgeons, which can improve the efficiency and safety of interventions. In this article we present five visualization methods to integrate augmented reality displays into medical procedures and the advantages and disadvantages are explained. Based on an extensive literature review the various existing approaches for integration of augmented reality displays into medical procedures are divided into five categories and the most important research results for each approach are presented. A large number of mixed and augmented reality solutions for medical interventions have been developed as research prototypes; however, only very few systems have been tested on patients. In order to integrate mixed and augmented reality displays into medical practice, highly specialized solutions need to be developed. Such systems must comply with the requirements with respect to accuracy, fidelity, ergonomics and seamless integration into the surgical workflow.
Design of a single projector multiview 3D display system
NASA Astrophysics Data System (ADS)
Geng, Jason
2014-03-01
Multiview three-dimensional (3D) display is able to provide horizontal parallax to viewers with high-resolution and fullcolor images being presented to each view. Most multiview 3D display systems are designed and implemented using multiple projectors, each generating images for one view. Although this multi-projector design strategy is conceptually straightforward, implementation of such multi-projector design often leads to a very expensive system and complicated calibration procedures. Even for a multiview system with a moderate number of projectors (e.g., 32 or 64 projectors), the cost of a multi-projector 3D display system may become prohibitive due to the cost and complexity of integrating multiple projectors. In this article, we describe an optical design technique for a class of multiview 3D display systems that use only a single projector. In this single projector multiview (SPM) system design, multiple views for the 3D display are generated in a time-multiplex fashion by the single high speed projector with specially designed optical components, a scanning mirror, and a reflective mirror array. Images of all views are generated sequentially and projected via the specially design optical system from different viewing directions towards a 3D display screen. Therefore, the single projector is able to generate equivalent number of multiview images from multiple viewing directions, thus fulfilling the tasks of multiple projectors. An obvious advantage of the proposed SPM technique is the significant reduction of cost, size, and complexity, especially when the number of views is high. The SPM strategy also alleviates the time-consuming procedures for multi-projector calibration. The design method is flexible and scalable and can accommodate systems with different number of views.
Linear perspective limitations on virtual reality and realistic displays
NASA Astrophysics Data System (ADS)
Temme, Leonard A.
2007-04-01
The visual images of the natural world, with their immediate intuitive appeal, seem like the logical gold standard for evaluating displays. After all, since photorealistic displays look so increasingly like the real world, what could be better? Part of the shortcoming of this intuitive appeal for displays is its naivete. Realism itself is full of potential illusions that we do not notice because, most of the time, realism is good enough for our everyday tasks. But when confronted with tasks that go beyond those for which our visual system has evolved, we may be blindsided. If we survive, blind to our erroneous perceptions and oblivious to our good fortune at having survived, we will not be any wiser next time. Realist displays depend on linear perspective (LP), the mathematical mapping of three dimensions onto two. Despite the fact that LP is a seductively elegant system that predicts results with defined mathematical procedures, artists do not stick to the procedures, not because they are math-phobic but because LP procedures, if followed explicitly, produce ugly, limited, and distorted images. If artists bother with formal LP procedures at all, they invariably temper the renderings by eye. The present paper discusses LP assumptions, limitations, and distortions. It provides examples of kluges to cover some of these LP shortcomings. It is important to consider the limitations of LP so that we do not let either naive assumptions or the seductive power of LP guide our thinking or expectations unrealistically as we consider its possible uses in advanced visual displays.
Imaging System for Vaginal Surgery.
Taylor, G Bernard; Myers, Erinn M
2015-12-01
The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.
Psychophysical contrast calibration
To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli
2013-01-01
Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843
Experience and Grouping Effects when Handling Non-Normal Situations
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
2004-01-01
Currently, most of the displays in control rooms can be categorized as status, alerts/procedures, or control screens. With the advent and use of CRTs and the associated computing power available to compute and display information, it is now possible to combine these different elements of information and control onto a single display. An experiment was conducted to determine which, if any, of these functions should be collocated in order to better handle simple anticipated non-normal system events. The results indicated that there are performance benefits and subject preferences to combining all the information onto one screen or combining the status and alert/procedure information onto one screen and placing the controls in another area. The results indicated that operators quickly modify their display preferences to the display configuration most recently used.
Advanced Technology Display House. Volume 1: Project Summary and Procedures
NASA Technical Reports Server (NTRS)
Maund, D. H.
1981-01-01
The Advanced Technology Display House (ATDH) project is described. Tasks are defined in the areas of energy demand, water demand, sewage treatment, electric power, plumbing, lighting, heating, and air conditioning. Energy, water, and sewage systems are defined.
NASA Astrophysics Data System (ADS)
Kay, Paul A.; Robb, Richard A.; King, Bernard F.; Myers, R. P.; Camp, Jon J.
1995-04-01
Thousands of radical prostatectomies for prostate cancer are performed each year. Radical prostatectomy is a challenging procedure due to anatomical variability and the adjacency of critical structures, including the external urinary sphincter and neurovascular bundles that subserve erectile function. Because of this, there are significant risks of urinary incontinence and impotence following this procedure. Preoperative interaction with three-dimensional visualization of the important anatomical structures might allow the surgeon to understand important individual anatomical relationships of patients. Such understanding might decrease the rate of morbidities, especially for surgeons in training. Patient specific anatomic data can be obtained from preoperative 3D MRI diagnostic imaging examinations of the prostate gland utilizing endorectal coils and phased array multicoils. The volumes of the important structures can then be segmented using interactive image editing tools and then displayed using 3-D surface rendering algorithms on standard work stations. Anatomic relationships can be visualized using surface displays and 3-D colorwash and transparency to allow internal visualization of hidden structures. Preoperatively a surgeon and radiologist can interactively manipulate the 3-D visualizations. Important anatomical relationships can better be visualized and used to plan the surgery. Postoperatively the 3-D displays can be compared to actual surgical experience and pathologic data. Patients can then be followed to assess the incidence of morbidities. More advanced approaches to visualize these anatomical structures in support of surgical planning will be implemented on virtual reality (VR) display systems. Such realistic displays are `immersive,' and allow surgeons to simultaneously see and manipulate the anatomy, to plan the procedure and to rehearse it in a realistic way. Ultimately the VR systems will be implemented in the operating room (OR) to assist the surgeon in conducting the surgery. Such an implementation will bring to the OR all of the pre-surgical planning data and rehearsal experience in synchrony with the actual patient and operation to optimize the effectiveness and outcome of the procedure.
NASA Technical Reports Server (NTRS)
Cheng, Thomas D.; Angelici, Gary L.; Slye, Robert E.; Ma, Matt
1991-01-01
The USDA presently uses labor-intensive photographic interpretation procedures to delineate large geographical areas into manageable size sampling units for the estimation of domestic crop and livestock production. Computer software to automate the boundary delineation procedure, called the computer-assisted stratification and sampling (CASS) system, was developed using a Hewlett Packard color-graphics workstation. The CASS procedures display Thematic Mapper (TM) satellite digital imagery on a graphics display workstation as the backdrop for the onscreen delineation of sampling units. USGS Digital Line Graph (DLG) data for roads and waterways are displayed over the TM imagery to aid in identifying potential sample unit boundaries. Initial analysis conducted with three Missouri counties indicated that CASS was six times faster than the manual techniques in delineating sampling units.
Flight crew interface aspects of forward-looking airborne windshear detection systems
NASA Technical Reports Server (NTRS)
Anderson, Charles D.; Carbaugh, David C.
1993-01-01
The goal of this research effort was to conduct analyses and research which could provide guidelines for design of the crew interface of an integrated windshear system. Addressed were HF issues, crew/system requirements, candidate display formats, alerting criteria, and crew procedures. A survey identified five flight management issues as top priority: missed alert acceptability; avoidance distance needed; false alert acceptability; nuisance rate acceptability; and crew procedures. Results of a simulation study indicated that the warning time for a look-ahead alert needs to be between 11 and 36 seconds (target of 23 seconds) before the reactive system triggers in order to be effective. Pilots considered the standard go-around maneuver most appropriate for look-ahead alerts, and the escape maneuvers used did not require lateral turns. Prototype display formats were reviewed or developed for alerting the crew; providing guidance to avoid or escape windshear; and status displays to provide windshear situational awareness. The three alerting levels now in use were considered appropriate, with a fourth (time-critical) level as a possible addition, although many reviewers felt only two levels of alerting were needed. Another survey gathered expert opinion on what crew procedures and alerting criteria should be used for look-ahead, or integrated, windshear systems, with a wide diversity of opinion in these areas.
48 CFR 52.213-1 - Fast Payment Procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 2 2012-10-01 2012-10-01 false Fast Payment Procedure. 52....213-1 Fast Payment Procedure. As prescribed in 13.404, insert the following clause: Fast Payment... contract, order, or blanket purchase agreement; and (ii) Display prominently on the invoice “FAST PAY...
48 CFR 52.213-1 - Fast Payment Procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 2 2011-10-01 2011-10-01 false Fast Payment Procedure. 52....213-1 Fast Payment Procedure. As prescribed in 13.404, insert the following clause: Fast Payment... contract, order, or blanket purchase agreement; and (ii) Display prominently on the invoice “FAST PAY...
48 CFR 52.213-1 - Fast Payment Procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 2 2014-10-01 2014-10-01 false Fast Payment Procedure. 52....213-1 Fast Payment Procedure. As prescribed in 13.404, insert the following clause: Fast Payment... contract, order, or blanket purchase agreement; and (ii) Display prominently on the invoice “FAST PAY...
48 CFR 52.213-1 - Fast Payment Procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Fast Payment Procedure. 52....213-1 Fast Payment Procedure. As prescribed in 13.404, insert the following clause: Fast Payment... contract, order, or blanket purchase agreement; and (ii) Display prominently on the invoice “FAST PAY...
48 CFR 52.213-1 - Fast Payment Procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Fast Payment Procedure. 52....213-1 Fast Payment Procedure. As prescribed in 13.404, insert the following clause: Fast Payment... contract, order, or blanket purchase agreement; and (ii) Display prominently on the invoice “FAST PAY...
NASA Technical Reports Server (NTRS)
Spiger, R. J.; Farrell, R. J.; Holcomb, G. A.
1982-01-01
The access schema developed to access both individual switch functions as well as automated or semiautomated procedures for the orbital maneuvering system and electrical power and distribution and control system discussed and the operation of the system is described. Feasibility tests and analyses used to define display parameters and to select applicable hardware choices for use in such a system are presented and the results are discussed.
Computed intraoperative navigation guidance--a preliminary report on a new technique.
Enislidis, G; Wagner, A; Ploder, O; Ewers, R
1997-08-01
To assess the value of a computer-assisted three-dimensional guidance system (Virtual Patient System) in maxillofacial operations. Laboratory and open clinical study. Teaching Hospital, Austria. 6 patients undergoing various procedures including removal of foreign body (n=3) and biopsy, maxillary advancement, and insertion of implants (n=1 each). Storage of computed tomographic (CT) pictures on an optical disc, and imposition of intraoperative video images on to these. The resulting display is shown to the surgeon on a micromonitor in his head-up display for guidance during the operations. To improve orientation during complex or minimally invasive maxillofacial procedures and to make such operations easier and less traumatic. Successful transferral of computed navigation technology into an operation room environment and positive evaluation of the method by the surgeons involved. Computer-assisted three-dimensional guidance systems have the potential for making complex or minimally invasive procedures easier to do, thereby reducing postoperative morbidity.
Performance tests and quality control of cathode ray tube displays.
Roehrig, H; Blume, H; Ji, T L; Browne, M
1990-08-01
Spatial resolution, noise, characteristic curve, and absolute luminance are the essential parameters that describe physical image quality of a display. This paper presents simple procedures for assessing the performance of a cathode ray tube (CRT) in terms of these parameters as well as easy set up techniques. The procedures can be used in the environment where the CRT is used. The procedures are based on a digital representation of the Society of Motion Pictures and Television Engineers pattern plus a few simple other digital patterns. Additionally, measurement techniques are discussed for estimating brightness uniformity, veiling glare, and distortion. Apart from the absolute luminance, all performance features can be assessed with an uncalibrated photodetector and the eyes of a human observer. The measurement techniques especially enable the user to perform comparisons of different display systems.
TDRSS momentum unload planning
NASA Technical Reports Server (NTRS)
Cross, George R.; Potter, Mitchell A.; Whitehead, J. Douglass; Smith, James T.
1991-01-01
A knowledge-based system is described which monitors TDRSS telemetry for problems in the momentum unload procedure. The system displays TDRSS telemetry and commands in real time via X-windows. The system constructs a momentum unload plan which agrees with the preferences of the attitude control specialists and the momentum growth characteristics of the individual spacecraft. During the execution of the plan, the system monitors the progress of the procedure and watches for unexpected problems.
XML syntax for clinical laboratory procedure manuals.
Saadawi, Gilan; Harrison, James H
2003-01-01
We have developed a document type description (DTD) in Extensable Markup Language (XML) for clinical laboratory procedures. Our XML syntax can adequately structure a variety of procedure types across different laboratories and is compatible with current procedure standards. The combination of this format with an XML content management system and appropriate style sheets will allow efficient procedure maintenance, distributed access, customized display and effective searching across a large body of test information.
Environmental Control Subsystem Development
NASA Technical Reports Server (NTRS)
Laidlaw, Jacob; Zelik, Jonathan
2017-01-01
Kennedy Space Center's Launch Pad 39B, part of Launch Complex 39, is currently undergoing construction to prepare it for NASA's Space Launch System missions. The Environmental Control Subsystem, which provides the vehicle with an air or nitrogen gas environment, required development of its local and remote display screens. The remote displays, developed by NASA contractors and previous interns, were developed without complete functionality; the remote displays were revised, adding functionality to over 90 displays. For the local displays, multiple test procedures were developed to assess the functionality of the screens, as well as verify requirements. One local display screen was also developed.
Real object-based 360-degree integral-floating display using multiple depth camera
NASA Astrophysics Data System (ADS)
Erdenebat, Munkh-Uchral; Dashdavaa, Erkhembaatar; Kwon, Ki-Chul; Wu, Hui-Ying; Yoo, Kwan-Hee; Kim, Young-Seok; Kim, Nam
2015-03-01
A novel 360-degree integral-floating display based on the real object is proposed. The general procedure of the display system is similar with conventional 360-degree integral-floating displays. Unlike previously presented 360-degree displays, the proposed system displays the 3D image generated from the real object in 360-degree viewing zone. In order to display real object in 360-degree viewing zone, multiple depth camera have been utilized to acquire the depth information around the object. Then, the 3D point cloud representations of the real object are reconstructed according to the acquired depth information. By using a special point cloud registration method, the multiple virtual 3D point cloud representations captured by each depth camera are combined as single synthetic 3D point cloud model, and the elemental image arrays are generated for the newly synthesized 3D point cloud model from the given anamorphic optic system's angular step. The theory has been verified experimentally, and it shows that the proposed 360-degree integral-floating display can be an excellent way to display real object in the 360-degree viewing zone.
A graphic system for telemetry monitoring and procedure performing at the Telecom SCC
NASA Technical Reports Server (NTRS)
Loubeyre, Jean Philippe
1994-01-01
The increasing amount of telemetry parameters and the increasing complexity of procedures used for the in-orbit satellite follow-up has led to the development of new tools for telemetry monitoring and procedures performing. The name of the system presented here is Graphic Server. It provides an advanced graphic representation of the satellite subsystems, including real-time telemetry and alarm displaying, and a powerful help for decision making with on line contingency procedures. Used for 2.5 years at the TELECOM S.C.C. for procedure performing, it has become an essential part of the S.C.C.
Novel application of simultaneous multi-image display during complex robotic abdominal procedures
2014-01-01
Background The surgical robot offers the potential to integrate multiple views into the surgical console screen, and for the assistant’s monitors to provide real-time views of both fields of operation. This function has the potential to increase patient safety and surgical efficiency during an operation. Herein, we present a novel application of the multi-image display system for simultaneous visualization of endoscopic views during various complex robotic gastrointestinal operations. All operations were performed using the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) with the assistance of Tilepro, multi-input display software, during employment of the intraoperative scopes. Three robotic operations, left hepatectomy with intraoperative common bile duct exploration, low anterior resection, and radical distal subtotal gastrectomy with intracorporeal gastrojejunostomy, were performed by three different surgeons at a tertiary academic medical center. Results The three complex robotic abdominal operations were successfully completed without difficulty or intraoperative complications. The use of the Tilepro to simultaneously visualize the images from the colonoscope, gastroscope, and choledochoscope made it possible to perform additional intraoperative endoscopic procedures without extra monitors or interference with the operations. Conclusion We present a novel use of the multi-input display program on the da Vinci Surgical System to facilitate the performance of intraoperative endoscopies during complex robotic operations. Our study offers another potentially beneficial application of the robotic surgery platform toward integration and simplification of combining additional procedures with complex minimally invasive operations. PMID:24628761
Incorporating Data Link Messaging into a Multi-function Display for General Aviation Aircraft
NASA Technical Reports Server (NTRS)
Adams, Catherine A.; Murdoch, Jennifer L.
2006-01-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness over conventional instrument flight rules (IFR) procedures.
Helping Hands: Using Augmented Reality to Provide Remote Guidance to Health Professionals.
Mather, Carey; Barnett, Tony; Broucek, Vlasti; Saunders, Annette; Grattidge, Darren; Huang, Weidong
2017-01-01
Access to expert practitioners or geographic distance can compound the capacity for appropriate supervision of health professionals in the workplace. Guidance and support of clinicians and students to undertake new or infrequent procedures can be resource intensive. The Helping Hands remote augmented reality system is an innovation to support the development of, and oversee the acquisition of procedural skills through remote learning and teaching supervision while in clinical practice. Helping Hands is a wearable, portable, hands-free, low cost system comprised of two networked laptops, a head-mounted display worn by the recipient and a display screen used remotely by the instructor. Hand hygiene was used as the test procedure as it is a foundation skill learned by all health profession students. The technology supports unmediated remote gesture guidance by augmenting the object with the Helping Hands of a health professional. A laboratory-based study and field trial tested usability and feasibility of the remote guidance system. The study found the Helping Hands system did not compromise learning outcomes. This innovation has the potential to transform remote learning and teaching supervision by enabling health professionals and students opportunities to develop and improve their procedural performance at the workplace.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCDANIEL, K.S.
1999-09-01
The test procedure provides for verifying indications and alarms The test procedure provides for verifying indications and alarms associated with the B Plant Canyon Ventilation System as they are being displayed on a remote monitoring workstation located in building 271-U. The system application software was installed by PLCS Plus under contract from B&W Hanford Company. The application software was installed on an existing operator workstation in building 271U which is owned and operated by Bechtel Hanford Inc.
Dressler, C R; Fischer, M; Burgert, O; Strauß, G
2012-06-01
This article analyzes the usage of an electronic patient record (EPR), which may be accessed intra-operatively by the surgeon. The focus lies on the automatic prioritization of documents to dramatically reduce the surgeon's interaction with the EPR system. An EPR system has been developed, which displays documents in accordance to the current procedure. The system is controlled by a foot switch and the documents are displayed on a large-scale screen in the operating room. The usage of the system by 2 surgeons has been recorded in clinical routine. 55 surgical procedures have been recorded. The EPR system has been used 2 times per procedure in average for surgeries at the middle ear, for surgeries of the paranasal sinuses, it has been used 1.3 times per procedure. The EPR-system has been used pre-operatively in 58% of cases. The surgeons did not have to interact with the EPR system for more than the half of the procedures to view the desired document. The existence of digitized documents in a clinic does not automatically lead to improved workflows. The evaluated EPR system presented the patient data in a simple and comfortable way. The extensive pre-operative usage had not been expected. Because of the low barrier to view patient data, higher patient safety may be assumed. On the other hand, the surgeon could be encouraged to skip the important preparation before the procedure. Due to the low pervasiveness of medical communication standards at this time, the integrated connection between clinic IT and an EPR system would nowadays only be possible by great efforts. © Georg Thieme Verlag KG Stuttgart · New York.
Automation of Command and Data Entry in a Glovebox Work Volume: An Evaluation of Data Entry Devices
NASA Technical Reports Server (NTRS)
Steele, Marianne K.; Nakamura, Gail; Havens, Cindy; LeMay, Moira
1996-01-01
The present study was designed to examine the human-computer interface for data entry while performing experimental procedures within a glovebox work volume in order to make a recommendation to the Space Station Biological Research Project for a data entry system to be used within the Life Sciences Glovebox. Test subjects entered data using either a manual keypad, similar to a standard computer numerical keypad located within the glovebox work volume, or a voice input system using a speech recognition program with a microphone headset. Numerical input and commands were programmed in an identical manner between the two systems. With both electronic systems, a small trackball was available within the work volume for cursor control. Data, such as sample vial identification numbers, sample tissue weights, and health check parameters of the specimen, were entered directly into procedures that were electronically displayed on a video monitor within the glovebox. A pen and paper system with a 'flip-chart' format for procedure display, similar to that currently in use on the Space Shuttle, was used as a baseline data entry condition. Procedures were performed by a single operator; eight test subjects were used in the study. The electronic systems were tested under both a 'nominal' or 'anomalous' condition. The anomalous condition was introduced into the experimental procedure to increase the probability of finding limitations or problems with human interactions with the electronic systems. Each subject performed five test runs during a test day: two procedures each with voice and keypad, one with and one without anomalies, and one pen and paper procedure. The data collected were both quantitative (times, errors) and qualitative (subjective ratings of the subjects).
Adams, Catherine A; Murdoch, Jennifer L; Consiglio, Maria C; Williams, Daniel M
2007-07-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots' subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness (SA) over conventional instrument flight rules (IFR) procedures.
System design and installation for RS600 programmable control system for solar heating and cooling
NASA Technical Reports Server (NTRS)
1978-01-01
Procedures for installing, operating, and maintaining a programmable control system which utilizes a F8 microprocessor to perform all timing, control, and calculation functions in order to customize system performance to meet individual requirements for solar heating, combined heating and cooling, and/or hot water systems are described. The manual discusses user configuration and options, displays, theory of operation, trouble-shooting procedures, and warranty and assistance. Wiring lists, parts lists, drawings, and diagrams are included.
Proposed evaluation framework for assessing operator performance with multisensor displays
NASA Technical Reports Server (NTRS)
Foyle, David C.
1992-01-01
Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.
Automation of scour analysis at Louisiana bridge sites : final report.
DOT National Transportation Integrated Search
1988-12-01
The computerized system for the organization, analysis, and display of field collected scour data is described. This system will enhance the current manual procedure of accomplishing these tasks. The system accepts input from the user, and based on u...
Electrical Distribution System (EDS) and Caution and Warning System (CWS)
NASA Technical Reports Server (NTRS)
Mcclung, T.
1975-01-01
An astronaut caution and warning system is described which monitors various life support system parameters and detects out-of-range parameter conditions. The warning system generates a warning tone and displays the malfunction condition to the astronaut along with the proper corrective procedures required.
Advanced automation of a prototypic thermal control system for Space Station
NASA Technical Reports Server (NTRS)
Dominick, Jeff
1990-01-01
Viewgraphs on an advanced automation of a prototypic thermal control system for space station are presented. The Thermal Expert System (TEXSYS) was initiated in 1986 as a cooperative project between ARC and JCS as a way to leverage on-going work at both centers. JSC contributed Thermal Control System (TCS) hardware and control software, TCS operational expertise, and integration expertise. ARC contributed expert system and display expertise. The first years of the project were dedicated to parallel development of expert system tools, displays, interface software, and TCS technology and procedures by a total of four organizations.
Lee, Joong Ho; Tanaka, Eiji; Woo, Yanghee; Ali, Güner; Son, Taeil; Kim, Hyoung-Il; Hyung, Woo Jin
2017-12-01
The recent scientific and technologic advances have profoundly affected the training of surgeons worldwide. We describe a novel intraoperative real-time training module, the Advanced Robotic Multi-display Educational System (ARMES). We created a real-time training module, which can provide a standardized step by step guidance to robotic distal subtotal gastrectomy with D2 lymphadenectomy procedures, ARMES. The short video clips of 20 key steps in the standardized procedure for robotic gastrectomy were created and integrated with TilePro™ software to delivery on da Vinci Surgical Systems (Intuitive Surgical, Sunnyvale, CA). We successfully performed the robotic distal subtotal gastrectomy with D2 lymphadenectomy for patient with gastric cancer employing this new teaching method without any transfer errors or system failures. Using this technique, the total operative time was 197 min and blood loss was 50 mL and there were no intra- or post-operative complications. Our innovative real-time mentoring module, ARMES, enables standardized, systematic guidance during surgical procedures. © 2017 Wiley Periodicals, Inc.
HASEGAWA, Mitsuhiro; NOURI, Mohsen; FUJISAWA, Hironori; HAYASHI, Yutaka; INAMASU, Joji; HIROSE, Yuichi; YAMASHITA, Junkoh
2015-01-01
There are many reports on position-related complications in neurosurgical literature but so far, continuous quantification of the patient’s position during the surgery has not been reported. This study aims to explore the utility of a new surgical table system and its software in displaying the patient’s body positions during surgery on real-time basis. More than 200 neurosurgical cases were monitored for their positions intra-operatively. The position was digitally recorded and could be seen by all the members in the operating team. It also displayed the three-dimensional relationship between the head and the heart positions. No position-related complications were observed during the study. The system was able to serve as an excellent indicator for monitoring the patient’s position. The recordings were analyzed and even used to reproduce or improve the position in the subsequent operations. The novel technique of monitoring the position of the head and the heart of the patients and the operating table planes are considered to be useful during delicate neurosurgical procedures thereby, preventing inadvertent procedural errors. This can be used to quantify various surgical positions in the future and define safety measures accordingly. PMID:25797776
Hasegawa, Mitsuhiro; Nouri, Mohsen; Fujisawa, Hironori; Hayashi, Yutaka; Inamasu, Joji; Hirose, Yuichi; Yamashita, Junkoh
2015-01-01
There are many reports on position-related complications in neurosurgical literature but so far, continuous quantification of the patient's position during the surgery has not been reported. This study aims to explore the utility of a new surgical table system and its software in displaying the patient's body positions during surgery on real-time basis. More than 200 neurosurgical cases were monitored for their positions intra-operatively. The position was digitally recorded and could be seen by all the members in the operating team. It also displayed the three-dimensional relationship between the head and the heart positions. No position-related complications were observed during the study. The system was able to serve as an excellent indicator for monitoring the patient's position. The recordings were analyzed and even used to reproduce or improve the position in the subsequent operations. The novel technique of monitoring the position of the head and the heart of the patients and the operating table planes are considered to be useful during delicate neurosurgical procedures thereby, preventing inadvertent procedural errors. This can be used to quantify various surgical positions in the future and define safety measures accordingly.
Study of cryogenic propellant systems for loading the space shuttle. Part 2: Hydrogen systems
NASA Technical Reports Server (NTRS)
Steward, W. G.
1975-01-01
Computer simulation studies of liquid hydrogen fill and vent systems for the space shuttle are studied. The computer programs calculate maximum and minimum permissible flow rates during cooldown as limited by thermal stress considerations, fill line cooldown time, pressure drop, flow rates, vapor content, vent line pressure drop and vent line discharge temperature. The input data for these programs are selected through graphic displays which schematically depict the part of the system being analyzed. The computed output is also displayed in the form of printed messages and graphs. Digital readouts of graph coordinates may also be obtained. Procedures are given for operation of the graphic display unit and the associated minicomputer and timesharing computer.
Wiebrands, Michael; Malajczuk, Chris J; Woods, Andrew J; Rohl, Andrew L; Mancera, Ricardo L
2018-06-21
Molecular graphics systems are visualization tools which, upon integration into a 3D immersive environment, provide a unique virtual reality experience for research and teaching of biomolecular structure, function and interactions. We have developed a molecular structure and dynamics application, the Molecular Dynamics Visualization tool, that uses the Unity game engine combined with large scale, multi-user, stereoscopic visualization systems to deliver an immersive display experience, particularly with a large cylindrical projection display. The application is structured to separate the biomolecular modeling and visualization systems. The biomolecular model loading and analysis system was developed as a stand-alone C# library and provides the foundation for the custom visualization system built in Unity. All visual models displayed within the tool are generated using Unity-based procedural mesh building routines. A 3D user interface was built to allow seamless dynamic interaction with the model while being viewed in 3D space. Biomolecular structure analysis and display capabilities are exemplified with a range of complex systems involving cell membranes, protein folding and lipid droplets.
Study of cryogenic propellant systems for loading the space shuttle
NASA Technical Reports Server (NTRS)
Voth, R. O.; Steward, W. G.; Hall, W. J.
1974-01-01
Computer programs were written to model the liquid oxygen loading system for the space shuttle. The programs allow selection of input data through graphic displays which schematically depict the part of the system being modeled. The computed output is also displayed in the form of graphs and printed messages. Any one of six computation options may be selected. The first four of these pertain to thermal stresses, pressure surges, cooldown times, flow rates and pressures during cooldown. Options five and six deal with possible water hammer effects due to closing of valves, steady flow and transient response to changes in operating conditions after cooldown. Procedures are given for operation of the graphic display unit and minicomputer.
NASA Technical Reports Server (NTRS)
Meng, J. C. S.; Thomson, J. A. L.
1975-01-01
A data analysis program constructed to assess LDV system performance, to validate the simulation model, and to test various vortex location algorithms is presented. Real or simulated Doppler spectra versus range and elevation is used and the spatial distributions of various spectral moments or other spectral characteristics are calculated and displayed. Each of the real or simulated scans can be processed by one of three different procedures: simple frequency or wavenumber filtering, matched filtering, and deconvolution filtering. The final output is displayed as contour plots in an x-y coordinate system, as well as in the form of vortex tracks deduced from the maxima of the processed data. A detailed analysis of run number 1023 and run number 2023 is presented to demonstrate the data analysis procedure. Vortex tracks and system range resolutions are compared with theoretical predictions.
Liu, Yang; Njuguna, Raphael; Matthews, Thomas; Akers, Walter J.; Sudlow, Gail P.; Mondal, Suman; Tang, Rui
2013-01-01
Abstract. We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal–oxide–semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in real time. The goggle is capable of detecting fluorescence of indocyanine green solution in the picomolar range. Aided by NIR quantum dots, we successfully used the fluorescence goggle to guide sentinel lymph node mapping in a rat model. We further demonstrated the feasibility of using the fluorescence goggle in guiding surgical resection of breast cancer metastases in the liver in conjunction with NIR fluorescent probes. These results illustrate the diverse potential use of the goggle system in surgical procedures. PMID:23728180
Multiprocessor graphics computation and display using transputers
NASA Technical Reports Server (NTRS)
Ellis, Graham K.
1988-01-01
A package of two-dimensional graphics routines was developed to run on a transputer-based parallel processing system. These routines were designed to enable applications programmers to easily generate and display results from the transputer network in a graphic format. The graphics procedures were designed for the lowest possible network communication overhead for increased performance. The routines were designed for ease of use and to present an intuitive approach to generating graphics on the transputer parallel processing system.
Arthroscopic knee surgery using the advanced flat panel high-resolution color head-mounted display
NASA Astrophysics Data System (ADS)
Nelson, Scott A.; Jones, D. E. Casey; St. Pierre, Patrick; Sampson, James B.
1997-06-01
The first ever deployed arthroscopic knee surgeries have been performed using a high resolution color head-mounted display (HMD) developed under the DARPA Advanced Flat Panel HMD program. THese procedures and several fixed hospital procedures have allowed both the system designers and surgeons to gain new insight into the use of a HMD for medical procedures in both community and combat support hospitals scenarios. The surgeons demonstrated and reported improved head-body orientation and awareness while using the HMD and reported several advantages and disadvantages of the HMD as compared to traditional CRT monitor viewing of the arthroscopic video images. The surgeries, the surgeon's comments, and a human factors overview of HMDs for Army surgical applications are discussed here.
MIRADS-2 Implementation Manual
NASA Technical Reports Server (NTRS)
1975-01-01
The Marshall Information Retrieval and Display System (MIRADS) which is a data base management system designed to provide the user with a set of generalized file capabilities is presented. The system provides a wide variety of ways to process the contents of the data base and includes capabilities to search, sort, compute, update, and display the data. The process of creating, defining, and loading a data base is generally called the loading process. The steps in the loading process which includes (1) structuring, (2) creating, (3) defining, (4) and implementing the data base for use by MIRADS are defined. The execution of several computer programs is required to successfully complete all steps of the loading process. This library must be established as a cataloged mass storage file as the first step in MIRADS implementation. The procedure for establishing the MIRADS Library is given. The system is currently operational for the UNIVAC 1108 computer system utilizing the Executive Operating System. All procedures relate to the use of MIRADS on the U-1108 computer.
Synthesis of an integrated cockpit management system
NASA Technical Reports Server (NTRS)
Dasaro, J. A.; Elliott, C. T.
1982-01-01
The process used in the synthesis of an integrated cockpit management system was discussed. Areas covered included flight displays, subsystem management, checklists, and procedures (both normal and emergency). The process of evolving from the unintegrated conventional system to the integrated system is examined and a brief description of the results presented.
SLIMMER--A UNIX System-Based Information Retrieval System.
ERIC Educational Resources Information Center
Waldstein, Robert K.
1988-01-01
Describes an information retrieval system developed at Bell Laboratories to create and maintain a variety of different but interrelated databases, and to provide controlled access to these databases. The components discussed include the interfaces, indexing rules, display languages, response time, and updating procedures of the system. (6 notes…
WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pickens, D; Flynn, M; Peck, D
Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinicalmore » MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.« less
State-of-the-art cockpit design for the HH-65A helicopters
NASA Technical Reports Server (NTRS)
Castleberry, D. E.; Mcelreath, M. Y.
1982-01-01
In the design of a HH-65A helicopter cockpit, advanced integrated electronics systems technology was employed to achieve several important goals for this multimission aircraft. They were: (1) integrated systems operation with consistent and simplified cockpit procedures; (2) mission-task-related cockpit displays and controls, and (3) reduced pilot instrument scan effort with excellent outside visibility. The integrated avionics system was implemented to depend heavily upon distributed but complementary processing, multiplex digital bus technology, and multifunction CRT controls and displays. This avionics system was completely flight tested and will soon enter operational service with the Coast Guard.
Eukaryotic ribosome display with in situ DNA recovery.
He, Mingyue; Edwards, Bryan M; Kastelic, Damjana; Taussig, Michael J
2012-01-01
Ribosome display is a cell-free display technology for in vitro selection and optimisation of proteins from large diversified libraries. It operates through the formation of stable protein-ribosome-mRNA (PRM) complexes and selection of ligand-binding proteins, followed by DNA recovery from the selected genetic information. Both prokaryotic and eukaryotic ribosome display systems have been developed. In this chapter, we describe the eukaryotic rabbit reticulocyte method in which a distinct in situ single-primer RT-PCR procedure is used to recover DNA from the selected PRM complexes without the need for prior disruption of the ribosome.
Real-time MRI guidance of cardiac interventions.
Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A
2017-10-01
Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:935-950. © 2017 International Society for Magnetic Resonance in Medicine.
Qualitative mechanism models and the rationalization of procedures
NASA Technical Reports Server (NTRS)
Farley, Arthur M.
1989-01-01
A qualitative, cluster-based approach to the representation of hydraulic systems is described and its potential for generating and explaining procedures is demonstrated. Many ideas are formalized and implemented as part of an interactive, computer-based system. The system allows for designing, displaying, and reasoning about hydraulic systems. The interactive system has an interface consisting of three windows: a design/control window, a cluster window, and a diagnosis/plan window. A qualitative mechanism model for the ORS (Orbital Refueling System) is presented to coordinate with ongoing research on this system being conducted at NASA Ames Research Center.
Dynamic alarm response procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, J.; Gordon, P.; Fitch, K.
2006-07-01
The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache{sup R}, IIS{sup R}, TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphicsmore » (SVG), such as Netscape{sup R}, Microsoft Internet Explorer{sup R}, Mozilla Firefox{sup R}, Opera{sup R}, and others. (authors)« less
NASA Technical Reports Server (NTRS)
Spiger, R. J.; Farrell, R. J.; Holcomb, G. A.
1982-01-01
Application of multifunction display and control systems to the NASA Orbiter spacecraft offers the potential for reducing crew workload and improving the presentation of system status and operational data to the crew. A design concept is presented for the application of a multifunction display and control system (MFDCS) to the Orbital Maneuvering System and Electrical Power Distribution and Control System on the Orbiter spacecraft. The MFDCS would provide the capability for automation of procedures, fault prioritization and software reconfiguration of the MFDCS data base. The MFDCS would operate as a stand-alone processor to minimize the impact on the current Orbiter software. Supervisory crew command of all current functions would be retained through the use of several operating modes in the system. Both the design concept and the processes followed in defining the concept are described.
Roll-Out and Turn-Off Display Software for Integrated Display System
NASA Technical Reports Server (NTRS)
Johnson, Edward J., Jr.; Hyer, Paul V.
1999-01-01
This report describes the software products, system architectures and operational procedures developed by Lockheed-Martin in support of the Roll-Out and Turn-Off (ROTO) sub-element of the Low Visibility Landing and Surface Operations (LVLASO) program at the NASA Langley Research Center. The ROTO portion of this program focuses on developing technologies that aid pilots in the task of managing the deceleration of an aircraft to a pre-selected exit taxiway. This report focuses on software that produces a system of redundant deceleration cues for a pilot during the landing roll-out, and presents these cues on a head up display (HUD). The software also produces symbology for aircraft operational phases involving cruise flight, approach, takeoff, and go-around. The algorithms and data sources used to compute the deceleration guidance and generate the displays are discussed. Examples of the display formats and symbology options are presented. Logic diagrams describing the design of the ROTO software module are also given.
Method and system for entering data within a flight plan entry field
NASA Technical Reports Server (NTRS)
Gibbs, Michael J. (Inventor); Van Omen, Debi (Inventor); Adams, Michael B. (Inventor); Chase, Karl L. (Inventor); Lewis, Daniel E. (Inventor); McCrobie, Daniel E. (Inventor)
2005-01-01
The present invention provides systems, apparatus and methods for entering data into a flight plan entry field which facilitates the display and editing of aircraft flight-plan data. In one embodiment, the present invention provides a method for entering multiple waypoint and procedure identifiers at once within a single a flight plan entry field. In another embodiment, the present invention provides for the partial entry of any waypoint or procedure identifiers, and thereafter relating the identifiers with an aircraft's flight management system to anticipate the complete text entry for display. In yet another embodiment, the present invention discloses a method to automatically provide the aircraft operator with selectable prioritized arrival and approach routing identifiers by a single manual selection. In another embodiment, the present invention is a method for providing the aircraft operator with selectable alternate patterns to a new runway.
Surgery applications of virtual reality
NASA Technical Reports Server (NTRS)
Rosen, Joseph
1994-01-01
Virtual reality is a computer-generated technology which allows information to be displayed in a simulated, bus lifelike, environment. In this simulated 'world', users can move and interact as if they were actually a part of that world. This new technology will be useful in many different fields, including the field of surgery. Virtual reality systems can be used to teach surgical anatomy, diagnose surgical problems, plan operations, simulate and perform surgical procedures (telesurgery), and predict the outcomes of surgery. The authors of this paper describe the basic components of a virtual reality surgical system. These components include: the virtual world, the virtual tools, the anatomical model, the software platform, the host computer, the interface, and the head-coupled display. In the chapter they also review the progress towards using virtual reality for surgical training, planning, telesurgery, and predicting outcomes. Finally, the authors present a training system being developed for the practice of new procedures in abdominal surgery.
Inventorying national forest resources...for planning-programing-budgeting system
Miles R. Hill; Elliot L. Amidon
1968-01-01
New systems for analyzing resource management problems, such as Planning-Programing-Budgeting, will require automated procedures to collect and assemble resource inventory data. A computer - oriented system called Map Information Assembly and Display System developed for this purpose was tested on a National Forest in California. It provided information on eight forest...
Large-screen display technology assessment for military applications
NASA Astrophysics Data System (ADS)
Blaha, Richard J.
1990-08-01
Full-color, large screen display systems can enhance military applications that require group presentation, coordinated decisions, or interaction between decision makers. The technology already plays an important role in operations centers, simulation facilities, conference rooms, and training centers. Some applications display situational, status, or briefing information, while others portray instructional material for procedural training or depict realistic panoramic scenes that are used in simulators. While each specific application requires unique values of luminance, resolution, response time, reliability, and the video interface, suitable performance can be achieved with available commercial large screen displays. Advances in the technology of large screen displays are driven by the commercial applications because the military applications do not provide the significant market share enjoyed by high definition television (HDTV), entertainment, advertisement, training, and industrial applications. This paper reviews the status of full-color, large screen display technologies and includes the performance and cost metrics of available systems. For this discussion, performance data is based upon either measurements made by our personnel or extractions from vendors' data sheets.
AMO EXPRESS: A Command and Control Experiment for Crew Autonomy
NASA Technical Reports Server (NTRS)
Stetson, Howard K.; Frank, Jeremy; Cornelius, Randy; Haddock, Angie; Wang, Lui; Garner, Larry
2015-01-01
NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control demonstration of intelligent procedures to automatically initialize a rack onboard the International Space Station (ISS) with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures provide a step-by-step messaging paradigm and a high level status upon termination. This messaging and high level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high level execution status was transmitted to ground, for WebPD consumption.
Flexible high-resolution display systems for the next generation of radiology reading rooms
NASA Astrophysics Data System (ADS)
Caban, Jesus J.; Wood, Bradford J.; Park, Adrian
2007-03-01
A flexible, scalable, high-resolution display system is presented to support the next generation of radiology reading rooms or interventional radiology suites. The project aims to create an environment for radiologists that will simultaneously facilitate image interpretation, analysis, and understanding while lowering visual and cognitive stress. Displays currently in use present radiologists with technical challenges to exploring complex datasets that we seek to address. These include resolution and brightness, display and ambient lighting differences, and degrees of complexity in addition to side-by-side comparison of time-variant and 2D/3D images. We address these issues through a scalable projector-based system that uses our custom-designed geometrical and photometrical calibration process to create a seamless, bright, high-resolution display environment that can reduce the visual fatigue commonly experienced by radiologists. The system we have designed uses an array of casually aligned projectors to cooperatively increase overall resolution and brightness. Images from a set of projectors in their narrowest zoom are combined at a shared projection surface, thus increasing the global "pixels per inch" (PPI) of the display environment. Two primary challenges - geometric calibration and photometric calibration - remained to be resolved before our high-resolution display system could be used in a radiology reading room or procedure suite. In this paper we present a method that accomplishes those calibrations and creates a flexible high-resolution display environment that appears seamless, sharp, and uniform across different devices.
Earth resources sensor data handling system: NASA JSC version
NASA Technical Reports Server (NTRS)
1974-01-01
The design of the NASA JSC data handling system is presented. Data acquisition parameters and computer display formats and the flow of image data through the system, with recommendations for improving system efficiency are discussed along with modifications to existing data handling procedures which will allow utilization of data duplication techniques and the accurate identification of imagery.
Haptic display for the VR arthroscopy training simulator
NASA Astrophysics Data System (ADS)
Ziegler, Rolf; Brandt, Christoph; Kunstmann, Christian; Mueller, Wolfgang; Werkhaeuser, Holger
1997-05-01
A specific desire to find new training methods arose from the new fields called 'minimal invasive surgery.' With the technical advance modern video arthroscopy became the standard procedure in the ORs. Holding the optical system with the video camera in one hand, watching the operation field on the monitor, the other hand was free to guide, e.g., a probe. As arthroscopy became a more common procedure it became obvious that some sort of special training was necessary to guarantee a certain level of qualification of the surgeons. Therefore, a hospital in Frankfurt, Germany approached the Fraunhofer Institute for Computer Graphics to develop a training system for arthroscopy based on VR techniques. At least the main drawback of the developed simulator is the missing of haptic perception, especially of force feedback. In cooperation with the Department of Electro-Mechanical Construction at the Darmstadt Technical University we have designed and built a haptic display for the VR arthroscopy training simulator. In parallel we developed a concept for the integration of the haptic display in a configurable way.
Geometric correction of satellite data using curvilinear features and virtual control points
NASA Technical Reports Server (NTRS)
Algazi, V. R.; Ford, G. E.; Meyer, D. I.
1979-01-01
A simple, yet effective procedure for the geometric correction of partial Landsat scenes is described. The procedure is based on the acquisition of actual and virtual control points from the line printer output of enhanced curvilinear features. The accuracy of this method compares favorably with that of the conventional approach in which an interactive image display system is employed.
Maintenance Procedure Display: Head Mounted Display (HMD) Evaluations
NASA Technical Reports Server (NTRS)
Whitmore, Milrian; Litaker, Harry L., Jr.; Solem, Jody A.; Holden, Kritina L.; Hoffman, Ronald R.
2007-01-01
A viewgraph presentation describing maintenance procedures for head mounted displays is shown. The topics include: 1) Study Goals; 2) Near Eye Displays (HMDs); 3) Design; 4) Phase I-Evaluation Methods; 5) Phase 1 Results; 6) Improved HMD Mounting; 7) Phase 2 -Evaluation Methods; 8) Phase 2 Preliminary Results; and 9) Next Steps.
Advanced Extravehicular Mobility Unit Informatics Software Design
NASA Technical Reports Server (NTRS)
Wright, Theodore
2014-01-01
This is a description of the software design for the 2013 edition of the Advanced Extravehicular Mobility Unit (AEMU) Informatics computer assembly. The Informatics system is an optional part of the space suit assembly. It adds a graphical interface for displaying suit status, timelines, procedures, and caution and warning information. In the future it will display maps with GPS position data, and video and still images captured by the astronaut.
Phage display for the discovery of hydroxyapatite-associated peptides.
Jin, Hyo-Eon; Chung, Woo-Jae; Lee, Seung-Wuk
2013-01-01
In nature, proteins play a critical role in the biomineralization process. Understanding how different peptide or protein sequences selectively interact with the target crystal is of great importance. Identifying such protein structures is one of the critical steps in verifying the molecular mechanisms of biomineralization. One of the promising ways to obtain such information for a particular crystal surface is to screen combinatorial peptide libraries in a high-throughput manner. Among the many combinatorial library screening procedures, phage display is a powerful method to isolate such proteins and peptides. In this chapter, we will describe our established methods to perform phage display with inorganic crystal surfaces. Specifically, we will use hydroxyapatite as a model system for discovery of apatite-associated proteins in bone or tooth biomineralization studies. This model approach can be generalized to other desired crystal surfaces using the same experimental design principles with a little modification of the procedures. © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lahti, Paul M.; Motyka, Eric J.; Lancashire, Robert J.
2000-05-01
A straightforward procedure is described to combine computation of molecular vibrational modes using commonly available molecular modeling programs with visualization of the modes using advanced features of the MDL Information Systems Inc. Chime World Wide Web browser plug-in. Minor editing of experimental spectra that are stored in the JCAMP-DX format allows linkage of IR spectral frequency ranges to Chime molecular display windows. The spectra and animation files can be combined by Hypertext Markup Language programming to allow interactive linkage between experimental spectra and computationally generated vibrational displays. Both the spectra and the molecular displays can be interactively manipulated to allow the user maximum control of the objects being viewed. This procedure should be very valuable not only for aiding students through visual linkage of spectra and various vibrational animations, but also by assisting them in learning the advantages and limitations of computational chemistry by comparison to experiment.
NASA Technical Reports Server (NTRS)
Aquila, V.; Derrig, D.; Griffith, G.
1986-01-01
Procedures are presented that allow the user to assemble tasks, link, compile, backup the system, generate/establish/print display pages, cancel tasks in memory, and to TET an assembly task without having to enter the commands every time. A list of acronyms is provided. Software identification, payload checkout unit operating system services, data base generation, and MITRA operating procedures are also discussed.
Advanced crew procedures development techniques
NASA Technical Reports Server (NTRS)
Arbet, J. D.; Benbow, R. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.; Tatum, I. C.
1975-01-01
The development of an operational computer program, the Procedures and Performance Program (PPP), is reported which provides a procedures recording and crew/vehicle performance monitoring capability. The PPP provides real time CRT displays and postrun hardcopy of procedures, difference procedures, performance, performance evaluation, and training script/training status data. During post-run, the program is designed to support evaluation through the reconstruction of displays to any point in time. A permanent record of the simulation exercise can be obtained via hardcopy output of the display data, and via magnetic tape transfer to the Generalized Documentation Processor (GDP). Reference procedures data may be transferred from the GDP to the PPP.
Human Machine Interface Programming and Testing
NASA Technical Reports Server (NTRS)
Foster, Thomas Garrison
2013-01-01
Human Machine Interface (HMI) Programming and Testing is about creating graphical displays to mimic mission critical ground control systems in order to provide NASA engineers with the ability to monitor the health management of these systems in real time. The Health Management System (HMS) is an online interactive human machine interface system that monitors all Kennedy Ground Control Subsystem (KGCS) hardware in the field. The Health Management System is essential to NASA engineers because it allows remote control and monitoring of the health management systems of all the Programmable Logic Controllers (PLC) and associated field devices. KGCS will have equipment installed at the launch pad, Vehicle Assembly Building, Mobile Launcher, as well as the Multi-Purpose Processing Facility. I am designing graphical displays to monitor and control new modules that will be integrated into the HMS. The design of the display screen will closely mimic the appearance and functionality of the actual modules. There are many different field devices used to monitor health management and each device has its own unique set of health management related data, therefore each display must also have its own unique way to display this data. Once the displays are created, the RSLogix5000 application is used to write software that maps all the required data read from the hardware to the graphical display. Once this data is mapped to its corresponding display item, the graphical display and hardware device will be connected through the same network in order to test all possible scenarios and types of data the graphical display was designed to receive. Test Procedures will be written to thoroughly test out the displays and ensure that they are working correctly before being deployed to the field. Additionally, the Kennedy Ground Controls Subsystem's user manual will be updated to explain to the NASA engineers how to use the new module displays.
Synthetic Vision Enhanced Surface Operations and Flight Procedures Rehearsal Tool
NASA Technical Reports Server (NTRS)
Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Williams, Steven P.; Kramer, Lynda J.
2006-01-01
Limited visibility has been cited as predominant causal factor for both Controlled-Flight-Into-Terrain (CFIT) and runway incursion accidents. NASA is conducting research and development of Synthetic Vision Systems (SVS) technologies which may potentially mitigate low visibility conditions as a causal factor to these accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. Two experimental evaluation studies were performed to determine the efficacy of two concepts: 1) head-worn display application of SVS technology to enhance transport aircraft surface operations, and 2) three-dimensional SVS electronic flight bag display concept for flight plan preview, mission rehearsal and controller-pilot data link communications interface of flight procedures. In the surface operation study, pilots evaluated two display devices and four display modes during taxi under unlimited and CAT II visibility conditions. In the mission rehearsal study, pilots flew approaches and departures in an operationally-challenged airport environment, including CFIT scenarios. Performance using the SVS concepts was compared to traditional baseline displays with paper charts only or EFB information. In general, the studies evince the significant situation awareness and enhanced operational capabilities afforded from these advanced SVS display concepts. The experimental results and conclusions from these studies are discussed along with future directions.
48 CFR 14.203-2 - Dissemination of information concerning invitations for bids.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 14.203-2 Dissemination of information concerning invitations for bids. Procedures concerning display... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Dissemination of information concerning invitations for bids. 14.203-2 Section 14.203-2 Federal Acquisition Regulations System...
ERIC Educational Resources Information Center
Fuller, C. A.
A breadboard model of a laser display system is described in detail and its operating procedure is outlined. The system consists of: a Model 52 argon krypton ion laser and power supply; an optical breadboard comprising a pocket cell light modulator, a galvonmeter beam deflector for vertical scanning, a unique multiple reflection beam steerer for…
21 CFR 892.1720 - Mobile x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Mobile x-ray system. 892.1720 Section 892.1720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... for diagnostic procedures. This generic type of device may include signal analysis and display...
21 CFR 892.1720 - Mobile x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Mobile x-ray system. 892.1720 Section 892.1720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... for diagnostic procedures. This generic type of device may include signal analysis and display...
21 CFR 892.1720 - Mobile x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Mobile x-ray system. 892.1720 Section 892.1720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... for diagnostic procedures. This generic type of device may include signal analysis and display...
21 CFR 892.1720 - Mobile x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Mobile x-ray system. 892.1720 Section 892.1720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... for diagnostic procedures. This generic type of device may include signal analysis and display...
21 CFR 892.1720 - Mobile x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mobile x-ray system. 892.1720 Section 892.1720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... for diagnostic procedures. This generic type of device may include signal analysis and display...
Autonomous power expert system advanced development
NASA Technical Reports Server (NTRS)
Quinn, Todd M.; Walters, Jerry L.
1991-01-01
The autonomous power expert (APEX) system is being developed at Lewis Research Center to function as a fault diagnosis advisor for a space power distribution test bed. APEX is a rule-based system capable of detecting faults and isolating the probable causes. APEX also has a justification facility to provide natural language explanations about conclusions reached during fault isolation. To help maintain the health of the power distribution system, additional capabilities were added to APEX. These capabilities allow detection and isolation of incipient faults and enable the expert system to recommend actions/procedure to correct the suspected fault conditions. New capabilities for incipient fault detection consist of storage and analysis of historical data and new user interface displays. After the cause of a fault is determined, appropriate recommended actions are selected by rule-based inferencing which provides corrective/extended test procedures. Color graphics displays and improved mouse-selectable menus were also added to provide a friendlier user interface. A discussion of APEX in general and a more detailed description of the incipient detection, recommended actions, and user interface developments during the last year are presented.
NASA Technical Reports Server (NTRS)
Westmoreland, Sally; Stow, Douglas A.
1992-01-01
A framework is proposed for analyzing ancillary data and developing procedures for incorporating ancillary data to aid interactive identification of land-use categories in land-use updates. The procedures were developed for use within an integrated image processsing/geographic information systems (GIS) that permits simultaneous display of digital image data with the vector land-use data to be updated. With such systems and procedures, automated techniques are integrated with visual-based manual interpretation to exploit the capabilities of both. The procedural framework developed was applied as part of a case study to update a portion of the land-use layer in a regional scale GIS. About 75 percent of the area in the study site that experienced a change in land use was correctly labeled into 19 categories using the combination of automated and visual interpretation procedures developed in the study.
NASA Technical Reports Server (NTRS)
1975-01-01
Signal processing equipment specifications, operating and test procedures, and systems design and engineering are described. Five subdivisions of the overall circuitry are treated: (1) the spectrum analyzer; (2) the spectrum integrator; (3) the velocity discriminator; (4) the display interface; and (5) the formatter. They function in series: (1) first in analog form to provide frequency resolution, (2) then in digital form to achieve signal to noise improvement (video integration) and frequency discrimination, and (3) finally in analog form again for the purpose of real-time display of the significant velocity data. The formatter collects binary data from various points in the processor and provides a serial output for bi-phase recording. Block diagrams are used to illustrate the system.
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1986-01-01
The topics of research in this program include pilot/vehicle analysis techniques, identification of pilot dynamics, and control and display synthesis techniques for optimizing aircraft handling qualities. The project activities are discussed. The current technical activity is directed at extending and validating the active display synthesis procedure, and the pilot/vehicle analysis of the NLR rate-command flight configurations in the landing task. Two papers published by the researchers are attached as appendices.
An XML Representation for Crew Procedures
NASA Technical Reports Server (NTRS)
Simpson, Richard C.
2005-01-01
NASA ensures safe operation of complex systems through the use of formally-documented procedures, which encode the operational knowledge of the system as derived from system experts. Crew members use procedure documentation on the ground for training purposes and on-board space shuttle and space station to guide their activities. Investigators at JSC are developing a new representation for procedures that is content-based (as opposed to display-based). Instead of specifying how a procedure should look on the printed page, the content-based representation will identify the components of a procedure and (more importantly) how the components are related (e.g., how the activities within a procedure are sequenced; what resources need to be available for each activity). This approach will allow different sets of rules to be created for displaying procedures on a computer screen, on a hand-held personal digital assistant (PDA), verbally, or on a printed page, and will also allow intelligent reasoning processes to automatically interpret and use procedure definitions. During his NASA fellowship, Dr. Simpson examined how various industries represent procedures (also called business processes or workflows), in areas such as manufacturing, accounting, shipping, or customer service. A useful method for designing and evaluating workflow representation languages is by determining their ability to encode various workflow patterns, which depict abstract relationships between the components of a procedure removed from the context of a specific procedure or industry. Investigators have used this type of analysis to evaluate how well-suited existing workflow representation languages are for various industries based on the workflow patterns that commonly arise across industry-specific procedures. Based on this type of analysis, it is already clear that existing workflow representations capture discrete flow of control (i.e., when one activity should start and stop based on when other activities start and stop), but do not capture the flow of data, materials, resources or priorities. Existing workflow representation languages are also limited to representing sequences of discrete activities, and cannot encode procedures involving continuous flow of information or materials between activities.
Natural Resource Information System. Volume 1: Overall description
NASA Technical Reports Server (NTRS)
1972-01-01
A prototype computer-based Natural Resource Information System was designed which could store, process, and display data of maximum usefulness to land management decision making. The system includes graphic input and display, the use of remote sensing as a data source, and it is useful at multiple management levels. A survey established current decision making processes and functions, information requirements, and data collection and processing procedures. The applications of remote sensing data and processing requirements were established. Processing software was constructed and a data base established using high-altitude imagery and map coverage of selected areas of SE Arizona. Finally a demonstration of system processing functions was conducted utilizing material from the data base.
NASA Technical Reports Server (NTRS)
Ray, Ronald J.; Hicks, John W.; Wichman, Keith D.
1991-01-01
Procedures for real time evaluation of the inflight health and performance of gas turbine engines and related systems were developed to enhance flight test safety and productivity. These techniques include the monitoring of the engine, the engine control system, thrust vectoring control system health, and the detection of engine stalls. Real time performance techniques were developed for the determination and display of inflight thrust and for aeroperformance drag polars. These new methods were successfully shown on various research aircraft at NASA-Dryden. The capability of NASA's Western Aeronautical Test Range and the advanced data acquisition systems were key factors for implementation and real time display of these methods.
NASA Technical Reports Server (NTRS)
Hess, R. A.
1976-01-01
Paramount to proper utilization of electronic displays is a method for determining pilot-centered display requirements. Display design should be viewed fundamentally as a guidance and control problem which has interactions with the designer's knowledge of human psychomotor activity. From this standpoint, reliable analytical models of human pilots as information processors and controllers can provide valuable insight into the display design process. A relatively straightforward, nearly algorithmic procedure for deriving model-based, pilot-centered display requirements was developed and is presented. The optimal or control theoretic pilot model serves as the backbone of the design methodology, which is specifically directed toward the synthesis of head-down, electronic, cockpit display formats. Some novel applications of the optimal pilot model are discussed. An analytical design example is offered which defines a format for the electronic display to be used in a UH-1H helicopter in a landing approach task involving longitudinal and lateral degrees of freedom.
Display/control requirements for automated VTOL aircraft
NASA Technical Reports Server (NTRS)
Hoffman, W. C.; Kleinman, D. L.; Young, L. R.
1976-01-01
A systematic design methodology for pilot displays in advanced commercial VTOL aircraft was developed and refined. The analyst is provided with a step-by-step procedure for conducting conceptual display/control configurations evaluations for simultaneous monitoring and control pilot tasks. The approach consists of three phases: formulation of information requirements, configuration evaluation, and system selection. Both the monitoring and control performance models are based upon the optimal control model of the human operator. Extensions to the conventional optimal control model required in the display design methodology include explicit optimization of control/monitoring attention; simultaneous monitoring and control performance predictions; and indifference threshold effects. The methodology was applied to NASA's experimental CH-47 helicopter in support of the VALT program. The CH-47 application examined the system performance of six flight conditions. Four candidate configurations are suggested for evaluation in pilot-in-the-loop simulations and eventual flight tests.
Evaluation of Hands-Free Devices for Space Habitat Maintenance Procedures
NASA Technical Reports Server (NTRS)
Hoffman, R. B.; Twyford, E.; Conlee, C. S.; Litaker, H. L.; Solemn, J. A.; Holden
2007-01-01
Currently, International Space Station (ISS) crews use a laptop computer to display procedures for performing onboard maintenance tasks. This approach has been determined to be suboptimal. A heuristic evaluation and two studies have been completed to test commercial off-the-shelf (COTS) "near-eye" heads up displays (HUDs) for support of these types of maintenance tasks. In both studies, subjects worked through electronic procedures to perform simple maintenance tasks. As a result of the Phase I study, three HUDs were down-selected to one. In the Phase II study, the HUD was compared against two other electronic display devices - a laptop computer and an e-book reader. Results suggested that adjustability and stability of the HUD display were the most significant acceptability factors to consider for near-eye displays. The Phase II study uncovered a number of advantages and disadvantages of the HUD relative to the laptop and e-book reader for interacting with electronic procedures.
EG&G Florida, Inc., KSC base operations contractor Launch Readiness Assessment System
NASA Technical Reports Server (NTRS)
Geaslen, W. D.
1988-01-01
A computerized Launch Readiness Assessment System (LRAS) which compares 'current status' of readiness against the 'required status' of readiness for the Space Shuttle. The five subsystems of the LRAS are examined in detail. The LRAS Plan specifies the overall system requirements, procedures, and reports. The LRAS Manager drives the operation of the LRAS system. The Responding Units (RU) maintain support plans and procedures which specify the detail requirements for each mission or milestone. The Master Data Tables contain the milestone, responsible RU relationships, and requirements assessment categories. The LRAS Status System serves as the launch readiness assessment reporting system. The relationships between these subsystems are displayed in diagrams.
Preliminary development of an intelligent computer assistant for engine monitoring
NASA Technical Reports Server (NTRS)
Disbrow, James D.; Duke, Eugene L.; Ray, Ronald J.
1989-01-01
As part of the F-18 high-angle-of-attack vehicle program, an AI method was developed for the real time monitoring of the propulsion system and for the identification of recovery procedures for the F404 engine. The aim of the development program is to provide enhanced flight safety and to reduce the duties of the propulsion engineers. As telemetry data is received, the results are continually displayed in a number of different color graphical formats. The system makes possible the monitoring of the engine state and the individual parameters. Anomaly information is immediately displayed to the engineer.
Natural Resource Information System. Volume 2: System operating procedures and instructions
NASA Technical Reports Server (NTRS)
1972-01-01
A total computer software system description is provided for the prototype Natural Resource Information System designed to store, process, and display data of maximum usefulness to land management decision making. Program modules are described, as are the computer file design, file updating methods, digitizing process, and paper tape conversion to magnetic tape. Operating instructions for the system, data output, printed output, and graphic output are also discussed.
Real-time self-calibration of a tracked augmented reality display
NASA Astrophysics Data System (ADS)
Baum, Zachary; Lasso, Andras; Ungi, Tamas; Fichtinger, Gabor
2016-03-01
PURPOSE: Augmented reality systems have been proposed for image-guided needle interventions but they have not become widely used in clinical practice due to restrictions such as limited portability, low display refresh rates, and tedious calibration procedures. We propose a handheld tablet-based self-calibrating image overlay system. METHODS: A modular handheld augmented reality viewbox was constructed from a tablet computer and a semi-transparent mirror. A consistent and precise self-calibration method, without the use of any temporary markers, was designed to achieve an accurate calibration of the system. Markers attached to the viewbox and patient are simultaneously tracked using an optical pose tracker to report the position of the patient with respect to a displayed image plane that is visualized in real-time. The software was built using the open-source 3D Slicer application platform's SlicerIGT extension and the PLUS toolkit. RESULTS: The accuracy of the image overlay with image-guided needle interventions yielded a mean absolute position error of 0.99 mm (95th percentile 1.93 mm) in-plane of the overlay and a mean absolute position error of 0.61 mm (95th percentile 1.19 mm) out-of-plane. This accuracy is clinically acceptable for tool guidance during various procedures, such as musculoskeletal injections. CONCLUSION: A self-calibration method was developed and evaluated for a tracked augmented reality display. The results show potential for the use of handheld image overlays in clinical studies with image-guided needle interventions.
Crew procedures development techniques
NASA Technical Reports Server (NTRS)
Arbet, J. D.; Benbow, R. L.; Hawk, M. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.
1975-01-01
The study developed requirements, designed, developed, checked out and demonstrated the Procedures Generation Program (PGP). The PGP is a digital computer program which provides a computerized means of developing flight crew procedures based on crew action in the shuttle procedures simulator. In addition, it provides a real time display of procedures, difference procedures, performance data and performance evaluation data. Reconstruction of displays is possible post-run. Data may be copied, stored on magnetic tape and transferred to the document processor for editing and documentation distribution.
NASA Technical Reports Server (NTRS)
Ohri, A. K.; Owen, H. A.; Wilson, T. G.; Rodriguez, G. E.
1974-01-01
The simulation of converter-controller combinations by means of a flexible digital computer program which produces output to a graphic display is discussed. The procedure is an alternative to mathematical analysis of converter systems. The types of computer programming involved in the simulation are described. Schematic diagrams, state equations, and output equations are displayed for four basic forms of inductor-energy-storage dc to dc converters. Mathematical models are developed to show the relationship of the parameters.
NASA Technical Reports Server (NTRS)
Cibula, W. G.
1976-01-01
The techniques used for the automated classification of marshland vegetation and for the color-coded display of remotely acquired data to facilitate the control of mosquito breeding are presented. A multispectral scanner system and its mode of operation are described, and the computer processing techniques are discussed. The procedures for the selection of calibration sites are explained. Three methods for displaying color-coded classification data are presented.
Utilization of a CRT display light pen in the design of feedback control systems
NASA Technical Reports Server (NTRS)
Thompson, J. G.; Young, K. R.
1972-01-01
A hierarchical structure of the interlinked programs was developed to provide a flexible computer-aided design tool. A graphical input technique and a data structure are considered which provide the capability of entering the control system model description into the computer in block diagram form. An information storage and retrieval system was developed to keep track of the system description, and analysis and simulation results, and to provide them to the correct routines for further manipulation or display. Error analysis and diagnostic capabilities are discussed, and a technique was developed to reduce a transfer function to a set of nested integrals suitable for digital simulation. A general, automated block diagram reduction procedure was set up to prepare the system description for the analysis routines.
Deib, Gerard; Johnson, Alex; Unberath, Mathias; Yu, Kevin; Andress, Sebastian; Qian, Long; Osgood, Gregory; Navab, Nassir; Hui, Ferdinand; Gailloud, Philippe
2018-05-30
Optical see-through head mounted displays (OST-HMDs) offer a mixed reality (MixR) experience with unhindered procedural site visualization during procedures using high resolution radiographic imaging. This technical note describes our preliminary experience with percutaneous spine procedures utilizing OST-HMD as an alternative to traditional angiography suite monitors. MixR visualization was achieved using the Microsoft HoloLens system. Various spine procedures (vertebroplasty, kyphoplasty, and percutaneous discectomy) were performed on a lumbar spine phantom with commercially available devices. The HMD created a real time MixR environment by superimposing virtual posteroanterior and lateral views onto the interventionalist's field of view. The procedures were filmed from the operator's perspective. Videos were reviewed to assess whether key anatomic landmarks and materials were reliably visualized. Dosimetry and procedural times were recorded. The operator completed a questionnaire following each procedure, detailing benefits, limitations, and visualization mode preferences. Percutaneous vertebroplasty, kyphoplasty, and discectomy procedures were successfully performed using OST-HMD image guidance on a lumbar spine phantom. Dosimetry and procedural time compared favorably with typical procedural times. Conventional and MixR visualization modes were equally effective in providing image guidance, with key anatomic landmarks and materials reliably visualized. This preliminary study demonstrates the feasibility of utilizing OST-HMDs for image guidance in interventional spine procedures. This novel visualization approach may serve as a valuable adjunct tool during minimally invasive percutaneous spine treatment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Technical Reports Server (NTRS)
Ranaudo, Richard J.; Martos, Borja; Norton, Bill W.; Gingras, David R.; Barnhart, Billy P.; Ratvasky, Thomas P.; Morelli, Eugene
2011-01-01
The utility of the Icing Contamination Envelope Protection (ICEPro) system for mitigating a potentially hazardous icing condition was evaluated by 29 pilots using the NASA Ice Contamination Effects Flight Training Device (ICEFTD). ICEPro provides real time envelope protection cues and alerting messages on pilot displays. The pilots participating in this test were divided into two groups; a control group using baseline displays without ICEPro, and an experimental group using ICEPro driven display cueing. Each group flew identical precision approach and missed approach procedures with a simulated failure case icing condition. Pilot performance, workload, and survey questionnaires were collected for both groups of pilots. Results showed that real time assessment cues were effective in reducing the number of potentially hazardous upset events and in lessening exposure to loss of control following an incipient upset condition. Pilot workload with the added ICEPro displays was not measurably affected, but pilot opinion surveys showed that real time cueing greatly improved their situation awareness of a hazardous aircraft state.
49 CFR 1542.211 - Identification systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... secured area or SIDA continuously displays the identification medium issued to that individual on the... individual who has authorized unescorted access to secured areas and SIDA's to ascertain the authority of any... approved identification media. The procedure must— (1) Apply uniformly in secured areas, SIDAs, and...
49 CFR 1542.211 - Identification systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... secured area or SIDA continuously displays the identification medium issued to that individual on the... individual who has authorized unescorted access to secured areas and SIDA's to ascertain the authority of any... approved identification media. The procedure must— (1) Apply uniformly in secured areas, SIDAs, and...
49 CFR 1542.211 - Identification systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... secured area or SIDA continuously displays the identification medium issued to that individual on the... individual who has authorized unescorted access to secured areas and SIDA's to ascertain the authority of any... approved identification media. The procedure must— (1) Apply uniformly in secured areas, SIDAs, and...
49 CFR 1542.211 - Identification systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... secured area or SIDA continuously displays the identification medium issued to that individual on the... individual who has authorized unescorted access to secured areas and SIDA's to ascertain the authority of any... approved identification media. The procedure must— (1) Apply uniformly in secured areas, SIDAs, and...
49 CFR 1542.211 - Identification systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... secured area or SIDA continuously displays the identification medium issued to that individual on the... individual who has authorized unescorted access to secured areas and SIDA's to ascertain the authority of any... approved identification media. The procedure must— (1) Apply uniformly in secured areas, SIDAs, and...
IMCS reflight certification requirements and design specifications
NASA Technical Reports Server (NTRS)
1984-01-01
The requirements for reflight certification are established. Software requirements encompass the software programs that are resident in the PCC, DEP, PDSS, EC, or any related GSE. A design approach for the reflight software packages is recommended. These designs will be of sufficient detail to permit the implementation of reflight software. The PDSS/IMC Reflight Certification system provides the tools and mechanisms for the user to perform the reflight certification test procedures, test data capture, test data display, and test data analysis. The system as defined will be structured to permit maximum automation of reflight certification procedures and test data analysis.
Continuation of advanced crew procedures development techniques
NASA Technical Reports Server (NTRS)
Arbet, J. D.; Benbow, R. L.; Evans, M. E.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.; Tatum, I. C.
1976-01-01
An operational computer program, the Procedures and Performance Program (PPP) which operates in conjunction with the Phase I Shuttle Procedures Simulator to provide a procedures recording and crew/vehicle performance monitoring capability was developed. A technical synopsis of each task resulting in the development of the Procedures and Performance Program is provided. Conclusions and recommendations for action leading to the improvements in production of crew procedures development and crew training support are included. The PPP provides real-time CRT displays and post-run hardcopy output of procedures, difference procedures, performance data, parametric analysis data, and training script/training status data. During post-run, the program is designed to support evaluation through the reconstruction of displays to any point in time. A permanent record of the simulation exercise can be obtained via hardcopy output of the display data and via transfer to the Generalized Documentation Processor (GDP). Reference procedures data may be transferred from the GDP to the PPP. Interface is provided with the all digital trajectory program, the Space Vehicle Dynamics Simulator (SVDS) to support initial procedures timeline development.
Inexpensive Monocular Pico-Projector-based Augmented Reality Display for Surgical Microscope
Shi, Chen; Becker, Brian C.; Riviere, Cameron N.
2013-01-01
This paper describes an inexpensive pico-projector-based augmented reality (AR) display for a surgical microscope. The system is designed for use with Micron, an active handheld surgical tool that cancels hand tremor of surgeons to improve microsurgical accuracy. Using the AR display, virtual cues can be injected into the microscope view to track the movement of the tip of Micron, show the desired position, and indicate the position error. Cues can be used to maintain high performance by helping the surgeon to avoid drifting out of the workspace of the instrument. Also, boundary information such as the view range of the cameras that record surgical procedures can be displayed to tell surgeons the operation area. Furthermore, numerical, textual, or graphical information can be displayed, showing such things as tool tip depth in the work space and on/off status of the canceling function of Micron. PMID:25264542
Evaluation of Model-Based Training for Vertical Guidance Logic
NASA Technical Reports Server (NTRS)
Feary, Michael; Palmer, Everett; Sherry, Lance; Polson, Peter; Alkin, Marty; McCrobie, Dan; Kelley, Jerry; Rosekind, Mark (Technical Monitor)
1997-01-01
This paper will summarize the results of a study which introduces a structured, model based approach to learning how the automated vertical guidance system works on a modern commercial air transport. The study proposes a framework to provide accurate and complete information in an attempt to eliminate confusion about 'what the system is doing'. This study will examine a structured methodology for organizing the ideas on which the system was designed, communicating this information through the training material, and displaying it in the airplane. Previous research on model-based, computer aided instructional technology has shown reductions in the amount of time to a specified level of competence. The lessons learned from the development of these technologies are well suited for use with the design methodology which was used to develop the vertical guidance logic for a large commercial air transport. The design methodology presents the model from which to derive the training material, and the content of information to be displayed to the operator. The study consists of a 2 X 2 factorial experiment which will compare a new method of training vertical guidance logic and a new type of display. The format of the material used to derive both the training and the display will be provided by the Operational Procedure Methodology. The training condition will compare current training material to the new structured format. The display condition will involve a change of the content of the information displayed into pieces that agree with the concepts with which the system was designed.
Energy Monitoring and Control Systems--Performance Verification and Endurance Test Procedures.
1982-12-01
EM-; tK2 s) trave h.en loadted in qvstem sit ~rp sm:l , o,1 ti-’.~ -1 rouiitthe factoz’, lest. E.VEF.NT Comnmwid the system to display the status of...contractor correction of all outstanding deficiencies . 163 TEST NO: END-i Page I of 1 OBJECTIVE: To demonstrate EMCS normal mode operation 24 TITLE: Endurance
Evaluation of Hands-Free Devices for the Display of Maintenance Procedures
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Hoffman, Ronald B.; Litaker, Harry, Jr.; Solem, Jody; Holden, Kritina; Twyford, Evan; Conlee, Carl
2007-01-01
Over the past year, NASA's focus has turned to crewed long duration and exploration missions. On these journeys, crewmembers will be required to execute thousands of procedures to maintain life support systems, check out space suits, conduct science experiments, and perform medical exams. To support the many complex tasks crewmembers undertake in microgravity, NASA is interested in providing crewmembers a hands-free work environment to promote more efficient operations. The overarching objective is to allow crewmembers to use both of their hands for tasks related to their mission, versus holding a paper manual or interacting with a display. The use of advanced, hands-free tools will undoubtedly make the crewmembers task easier, but they can also add to overall task complexity if not properly designed. A leading candidate technology for supporting a hands-free environment is the Head-Mounted Display (HMD). A more recent technology (e-book reader) that could be easily temp-stowed near the work area is also a potential hands-free solution. Previous work at NASA involved the evaluation of several commercially available HMDs for visual quality, comfort, and fit, as well as suitability for use in microgravity. Based on results from this work, three HMDs were selected for further evaluation (along with an e-book reader), using International Space Station (ISS)-like maintenance procedures. Two evaluations were conducted in the Space Station Mockup and Trainer Facility (SSMTF) located at the NASA Johnson Space Center (building 9). The SSMTF is a full scale, medium fidelity replica of the pressurized portions of the ISS. It supports crew training such as ingress and egress, habitability, and emergency procedures. In each of the two evaluations, the participants performed two maintenance procedures. One maintenance procedure involved inspecting air filters in a life support system and replacing them with a clean filter if one were found to be contaminated. The second maintenance procedure focused on working in a confined space; specifically, pulling down a rack to inspect wiring configurations, and rewiring in a different pattern. The maintenance procedures were selected to assess mobility, tool use, and access to multiple document sources during task performance. That is, the participant had to move from rack to rack, use a wrench, a camera, etc., replace components, and refer to diagrams to complete tasks. A constraint was imposed that the ISS-like format of the procedures was to be retained, and not modified or optimized for the electronic device ("plug and play" approach). This was based on future plans to test with real procedures on ISS.
Target controlled infusion for kids: trials and simulations.
Mehta, Disha; McCormack, Jon; Fung, Parry; Dumont, Guy; Ansermino, J
2008-01-01
Target controlled infusion (TCI) for Kids is a computer controlled system designed to administer propofol for general anesthesia. A controller establishes infusion rates required to achieve a specified concentration at the drug's effect site (C(e)) by implementing a continuously updated pharmacokinetic-pharmacodymanic model. This manuscript provides an overview of the system's design, preclinical tests, and a clinical pilot study. In pre-clinical tests, predicted infusion rates for 20 simulated procedures displayed complete convergent validity between two software implementations, Labview and Matlab, at computational intervals of 5, 10, and 15s, but diverged with 20s intervals due to system rounding errors. The volume of drug delivered by the TCI system also displayed convergent validity with Tivatrainer, a widely used TCI simulation software. Further tests, were conducted for 50 random procedures to evaluate discrepancies between volumes reported and those actually delivered by the system. Accuracies were within clinically acceptable ranges and normally distributed with a mean of 0.08 +/- 0.01 ml. In the clinical study, propofol pharmacokinetics were simulated for 30 surgical procedures involving children aged 3 months to 9 years. Predicted C(e) values during standard clinical practice, the accuracy of wake-up times predicted by the system, and potential correlations between patient wake-up times, C(e), and state entropy (SE) were assessed. Neither Ce nor SE was a reliable predictor of wake-up time in children, but the small sample size of this study does not fully accommodate the noted variation in children's response to propofol. A C(e) value of 1.9 mug/ml was found to best predict emergence from anesthesia in children.
Design and implementation of a PC-based image-guided surgical system.
Stefansic, James D; Bass, W Andrew; Hartmann, Steven L; Beasley, Ryan A; Sinha, Tuhin K; Cash, David M; Herline, Alan J; Galloway, Robert L
2002-11-01
In interactive, image-guided surgery, current physical space position in the operating room is displayed on various sets of medical images used for surgical navigation. We have developed a PC-based surgical guidance system (ORION) which synchronously displays surgical position on up to four image sets and updates them in real time. There are three essential components which must be developed for this system: (1) accurately tracked instruments; (2) accurate registration techniques to map physical space to image space; and (3) methods to display and update the image sets on a computer monitor. For each of these components, we have developed a set of dynamic link libraries in MS Visual C++ 6.0 supporting various hardware tools and software techniques. Surgical instruments are tracked in physical space using an active optical tracking system. Several of the different registration algorithms were developed with a library of robust math kernel functions, and the accuracy of all registration techniques was thoroughly investigated. Our display was developed using the Win32 API for windows management and tomographic visualization, a frame grabber for live video capture, and OpenGL for visualization of surface renderings. We have begun to use this current implementation of our system for several surgical procedures, including open and minimally invasive liver surgery.
Flat panel display test and evaluation: procedures, standards, and facilities
NASA Astrophysics Data System (ADS)
Jackson, Timothy W.; Daniels, Reginald; Hopper, Darrel G.
1997-07-01
This paper addresses flat panel display test and evaluation via a discussion of procedures, standards and facilities. Procedures need to be carefully developed and documented to ensure that test accomplished in separate laboratories produce comparable results. The tests themselves must not be a source of inconsistency in test results when such comparisons are made in the course of procurements or new technology prototype evaluations. Standards are necessary to expedite the transition of the new display technologies into applications and to lower the costs of custom parts applied across disparate applications. The flat panel display industry is in the course of ascertaining and formulating such standards as they are of value to designers, manufacturers, marketers and users of civil and military products and equipment. Additionally, in order to inform the DoD and industry, the test and evaluation facilities of the Air Force Research Laboratory Displays Branch are described. These facilities are available to support procurements involving flat panel displays and to examine new technology prototypes. Finally, other government display testing facilities within the Navy and the Army are described.
Density Gradient Columns for Chemical Displays.
ERIC Educational Resources Information Center
Guenther, William B.
1986-01-01
Procedures for preparing density gradient columns for chemical displays are presented. They include displays illustrating acid-base reactions, metal ion equilibria, and liquid density. The lifetime of these metastable displays is surprising, some lasting for months in display cabinets. (JN)
14 CFR 15.101 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PROCEDURAL RULES... (b) Aeronautical data that— (1) Is visually displayed in the cockpit of an aircraft; and (2) When visually displayed, accurately depicts a defective or deficient flight procedure or airway promulgated by...
NASA Technical Reports Server (NTRS)
Coiner, J. C.; Bruce, R. C.
1978-01-01
An aircraft/Landsat change-detection study conducted 1948-1972 on Marinduque Province, Republic of the Philippines, is discussed, and a procedure using both remote sensing and information systems for collection, spatial analysis, and display of periodic data is described. Each of the 4,008 25-hectare cells representing Marinduque were observed, and changes in and between variables were measured and tested using nonparametric statistics to determine the effect of specific land cover changes. Procedures using Landsat data to obtain a more continuous updating of the data base are considered. The system permits storage and comparison of historical and current data.
M-DAS: System for multispectral data analysis. [in Saginaw Bay, Michigan
NASA Technical Reports Server (NTRS)
Johnson, R. H.
1975-01-01
M-DAS is a ground data processing system designed for analysis of multispectral data. M-DAS operates on multispectral data from LANDSAT, S-192, M2S and other sources in CCT form. Interactive training by operator-investigators using a variable cursor on a color display was used to derive optimum processing coefficients and data on cluster separability. An advanced multivariate normal-maximum likelihood processing algorithm was used to produce output in various formats: color-coded film images, geometrically corrected map overlays, moving displays of scene sections, coverage tabulations and categorized CCTs. The analysis procedure for M-DAS involves three phases: (1) screening and training, (2) analysis of training data to compute performance predictions and processing coefficients, and (3) processing of multichannel input data into categorized results. Typical M-DAS applications involve iteration between each of these phases. A series of photographs of the M-DAS display are used to illustrate M-DAS operation.
105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
KINKEL, C.C.
1999-12-14
This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less
DOT National Transportation Integrated Search
2000-02-01
The new Display System Replacement (DSR) being implemented in air route traffic control centers (ARTCCs) will allow the data-side controller less room to post Flight Progress Strips (FPSs). We tested a new FPS marking and posting procedure designed t...
Sensory Discrimination, Generalization and Language Training of Autistic Children. Final Report.
ERIC Educational Resources Information Center
Blanton, Richard L.; And Others
The report presents summaries of 11 studies performed on 25-45 autistic students in a residential center to investigate processes of discrimination and response acquisition using automated reinforcement technology and exact timing procedures. The computer operated display and recording system for language and discrimination training is described…
The Launch Processing System for Space Shuttle.
NASA Technical Reports Server (NTRS)
Springer, D. A.
1973-01-01
In order to reduce costs and accelerate vehicle turnaround, a single automated system will be developed to support shuttle launch site operations, replacing a multiplicity of systems used in previous programs. The Launch Processing System will provide real-time control, data analysis, and information display for the checkout, servicing, launch, landing, and refurbishment of the launch vehicles, payloads, and all ground support systems. It will also provide real-time and historical data retrieval for management and sustaining engineering (test records and procedures, logistics, configuration control, scheduling, etc.).
Key Cognitive Issues in the Design of Electronic Displays of Instrument Approach Procedure Charts
DOT National Transportation Integrated Search
1993-11-01
This report provides a general introduction to the field of cognitive psychology and the application of well researched cognitive issues to the design of electronic instrument approach procedures (EIAP) displays. It presents 46 cognitive issues and 1...
77 FR 37795 - Airworthiness Directives; Dassault Aviation Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
... display of ELEC:LH ESS PWR LO or ELEC:LH ESS NO PWR (Abnormal procedure 3-190-40), land at nearest suitable airport Upon display of ELEC:RH ESS PWR LO and ELEC:RH ESS NO PWR (Abnormal procedure 3-190-45...
Head-Worn Displays for NextGen
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Shelton, Kevin J.; Arthur, J. J.
2011-01-01
The operating concepts emerging under the Next Generation air transportation system (NextGen) require new technology and procedures - not only on the ground-side - but also on the flight deck. Flight deck display and decision support technologies are specifically targeted to overcome aircraft safety barriers that might otherwise constrain the full realization of NextGen. One such technology is the very lightweight, unobtrusive head-worn display (HWD). HWDs with an integrated head-tracking system are being researched as they offer significant potential benefit under emerging NextGen operational concepts. Two areas of benefit for NextGen are defined. First, the HWD may be designed to be equivalent to the Head-Up Display (HUD) using Virtual HUD concepts. As such, these operational credits may be provided to significantly more aircraft for which HUD installation is neither practical nor possible. Second, the HWD provides unique display capabilities, such as an unlimited field-of-regard. These capabilities may be integral to emerging NextGen operational concepts, eliminating safety issues which might otherwise constrain the full realization of NextGen. The paper details recent research results, current HWD technology limitations, and future technology development needed to realize HWDs as a enabling technology for NextGen.
Human interaction with wearable computer systems: a look at glasses-mounted displays
NASA Astrophysics Data System (ADS)
Revels, Allen R.; Quill, Laurie L.; Kancler, David E.; Masquelier, Barbara L.
1998-09-01
With the advancement of technology and the information explosion, integration of the two into performance aiding systems can have a significant impact on operational and maintenance environments. The Department of Defense and commercial industry have made great strides in digitizing and automating technical manuals and data to be presented on performance aiding systems. These performance aides are computerized interactive systems that provide procedures on how to operate and maintain fielded systems. The idea is to provide the end-user a system which is compatible with their work environment. The purpose of this paper is to show, historically, the progression of wearable computer aiding systems for maintenance environments, and then highlight the work accomplished in the design and development of glasses- mounted displays (GMD). The paper reviews work performed over the last seven years, then highlights, through review of a usability study, the advances made with GMDs. The use of portable computing systems, such as laptop and notebook, computers, does not necessarily increase the accessibility of the displayed information while accomplishing a given task in a hands-busy, mobile work environment. The use of a GMD increases accessibility of the information by placing it in eye sight of the user without obstructing the surrounding environment. Although the potential utility for this type of display is great, hardware and human integration must be refined. Results from the usability study show the usefulness and usability of the GMD in a mobile, hands-free environment.
Rudnick, Paul A.; Clauser, Karl R.; Kilpatrick, Lisa E.; Tchekhovskoi, Dmitrii V.; Neta, Pedatsur; Blonder, Nikša; Billheimer, Dean D.; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Ham, Amy-Joan L.; Jaffe, Jacob D.; Kinsinger, Christopher R.; Mesri, Mehdi; Neubert, Thomas A.; Schilling, Birgit; Tabb, David L.; Tegeler, Tony J.; Vega-Montoto, Lorenzo; Variyath, Asokan Mulayath; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Paulovich, Amanda G.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Tempst, Paul; Liebler, Daniel C.; Stein, Stephen E.
2010-01-01
A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications. PMID:19837981
Network of fully integrated multispecialty hospital imaging systems
NASA Astrophysics Data System (ADS)
Dayhoff, Ruth E.; Kuzmak, Peter M.
1994-05-01
The Department of Veterans Affairs (VA) DHCP Imaging System records clinically significant diagnostic images selected by medical specialists in a variety of departments, including radiology, cardiology, gastroenterology, pathology, dermatology, hematology, surgery, podiatry, dental clinic, and emergency room. These images are displayed on workstations located throughout a medical center. All images are managed by the VA's hospital information system, allowing integrated displays of text and image data across medical specialties. Clinicians can view screens of `thumbnail' images for all studies or procedures performed on a selected patient. Two VA medical centers currently have DHCP Imaging Systems installed, and others are planned. All VA medical centers and other VA facilities are connected by a wide area packet-switched network. The VA's electronic mail software has been modified to allow inclusion of binary data such as images in addition to the traditional text data. Testing of this multimedia electronic mail system is underway for medical teleconsultation.
NASA Technical Reports Server (NTRS)
Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.
2007-01-01
The use of enhanced vision systems in civil aircraft is projected to increase rapidly as the Federal Aviation Administration recently changed the aircraft operating rules under Part 91, revising the flight visibility requirements for conducting approach and landing operations. Operators conducting straight-in instrument approach procedures may now operate below the published approach minimums when using an approved enhanced flight vision system that shows the required visual references on the pilot's Head-Up Display. An experiment was conducted to evaluate the complementary use of synthetic vision systems and enhanced vision system technologies, focusing on new techniques for integration and/or fusion of synthetic and enhanced vision technologies and crew resource management while operating under these newly adopted rules. Experimental results specific to flight crew response to non-normal events using the fused synthetic/enhanced vision system are presented.
Video stereo-laparoscopy system
NASA Astrophysics Data System (ADS)
Xiang, Yang; Hu, Jiasheng; Jiang, Huilin
2006-01-01
Minimally invasive surgery (MIS) has contributed significantly to patient care by reducing the morbidity associated with more invasive procedures. MIS procedures have become standard treatment for gallbladder disease and some abdominal malignancies. The imaging system has played a major role in the evolving field of minimally invasive surgery (MIS). The image need to have good resolution, large magnification, especially, the image need to have depth cue at the same time the image have no flicker and suit brightness. The video stereo-laparoscopy system can meet the demand of the doctors. This paper introduces the 3d video laparoscopy has those characteristic, field frequency: 100Hz, the depth space: 150mm, resolution: 10pl/mm. The work principle of the system is introduced in detail, and the optical system and time-division stereo-display system are described briefly in this paper. The system has focusing image lens, it can image on the CCD chip, the optical signal can change the video signal, and through A/D switch of the image processing system become the digital signal, then display the polarized image on the screen of the monitor through the liquid crystal shutters. The doctors with the polarized glasses can watch the 3D image without flicker of the tissue or organ. The 3D video laparoscope system has apply in the MIS field and praised by doctors. Contrast to the traditional 2D video laparoscopy system, it has some merit such as reducing the time of surgery, reducing the problem of surgery and the trained time.
Mono-stereo-autostereo: the evolution of 3-dimensional neurosurgical planning.
Stadie, Axel T; Kockro, Ralf A
2013-01-01
In the past decade, surgery planning has changed significantly. The main reason is the improvements in computer graphical rendering power and display technology, which turned the plain graphics of the mid-1990s into interactive stereoscopic objects. To report our experiences with 2 virtual reality systems used for planning neurosurgical operations. A series of 208 operations were planned with the Dextroscope (Bracco AMT, Singapore) requiring the use of liquid crystal display shutter glasses. The participating neurosurgeons answered a questionnaire after the planning procedure and postoperatively. In a second prospective series of 33 patients, we used an autostereoscopic monitor system (MD20-3-D; Setred SA, Sweden) to plan intracranial operations. A questionnaire regarding the value of surgery planning was answered preoperatively and postoperatively. The Dextroscope could be integrated into daily surgical routine. Surgeons regarded their understanding of the pathoanatomical situation as improved, leading to enhanced intraoperative orientation and confidence compared with conventional planning. The autostereoscopic Setred system was regarded as helpful in establishing the surgical strategy and analyzing the pathoanatomical situation compared with conventional planning. Both systems were perceived as a backup in case of failure of the standard navigation system. Improvement of display and interaction techniques adds to the realism of the planning process and enables precise structural understanding preoperatively. This minimizes intraoperative guesswork and exploratory dissection. Autostereoscopic display techniques will further increase the value and acceptance of 3-dimensional planning and intraoperative navigation.
NASA Technical Reports Server (NTRS)
Stetson, Howard K.; Haddock, Angie T.; Frank, Jeremy; Cornelius, Randy; Wang, Lui; Garner, Larry
2015-01-01
NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control experiment on-board the International Space Station that demonstrated single action intelligent procedures for crew command and control. The target problem was to enable crew initialization of a facility class rack with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as initialization of a medical facility to respond to a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). Utilization of Draper Laboratory's Timeliner software, deployed on-board the ISS within the Command and Control (C&C) computers and the Payload computers, allowed development of the automated procedures specific to ISS without having to certify and employ novel software for procedure development and execution. The procedures contained the ground procedure logic and actions as possible to include fault detection and recovery capabilities. The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures (via Timerliner) provide a step-by-step messaging paradigm and a high-level status upon termination. This messaging and high-level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. WebPD is a web based application that serves as the user interface for electronic procedure execution. It incorporates several aspects of the HTML5 standard. Procedures are written in a dialect of XML called Procedure Representation Language (PRL). WebPD tracks execution status in the procedure or procedures being displayed. WebPD aggregates and simplifies the auto-sequence execution status information, and formatted to be easily followed and understood by an operator who is not dedicated to actively monitoring the task. WebPD also provides an integrated data and control interface to pause or halt the execution in order to provide a check point of operation and to examine progress before starting the next sequence of activities. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high-level execution status was written to PLMDM memory. This memory is read and downlinked via Ku-Band at a 1 Hz rate. The data containing the high-level execution status is de-commutated on the ground, and rebroadcast for WebPD consumption. A future demonstration will be performed onboard, with ISS astronauts initiating the operations instead of ground controllers. The AMO EXPRESS experiment demonstrated activation and de-activation of EXPRESS rack 7, providing the capability of future single button activations and deactivations of facility class racks. The experiment achieved numerous technical and operations 'firsts' for the ISS
Pilot Preferences for Information Provided and Its Format for Status, Alerts, and Controls
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
2004-01-01
With the increased use of cathode ray tubes (CRTs) in flight decks and the computing power available, it is possible to combine status screens, alerts/procedures screens, and control screens onto a single display. This report presents the results of a survey designed to assess the perceived helpfulness and need of various pieces of information that could be included on status and control screens. The results from the survey indicate that operators want parameter ranges that change depending on the current aircraft configuration shown on bow-tie or dial displays. These displays should show the current value, normal range, alert type and range, and predictive information. Respondents wanted to see system relationships to one another for both component control and menu selection. When bringing up these various displays, this information should come up with a single button push. Finally, checklists should sense when a component has changed to the desired state.
Situational Lightning Climatologies for Central Florida: Phase III
NASA Technical Reports Server (NTRS)
Barrett, Joe H., III
2008-01-01
This report describes work done by the Applied Meteorology Unit (AMU) to add composite soundings to the Advanced Weather Interactive Processing System (AWIPS). This allows National Weather Service (NWS) forecasters to compare the current atmospheric state with climatology. In a previous phase, the AMU created composite soundings for four rawinsonde observation stations in Florida, for each of eight flow regimes. The composite soundings were delivered to the NWS Melbourne (MLB) office for display using the NSHARP software program. NWS MLB requested that the AMU make the composite soundings available for display in AWIPS. The AMU first created a procedure to customize AWIPS so composite soundings could be displayed. A unique four-character identifier was created for each of the 32 composite soundings. The AMU wrote a Tool Command Language/Tool Kit (TcVTk) software program to convert the composite soundings from NSHARP to Network Common Data Form (NetCDF) format. The NetCDF files were then displayable by AWIPS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T.; Carelsen, Bart
PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase).more » During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.« less
Full-parallax 3D display from stereo-hybrid 3D camera system
NASA Astrophysics Data System (ADS)
Hong, Seokmin; Ansari, Amir; Saavedra, Genaro; Martinez-Corral, Manuel
2018-04-01
In this paper, we propose an innovative approach for the production of the microimages ready to display onto an integral-imaging monitor. Our main contribution is using a stereo-hybrid 3D camera system, which is used for picking up a 3D data pair and composing a denser point cloud. However, there is an intrinsic difficulty in the fact that hybrid sensors have dissimilarities and therefore should be equalized. Handled data facilitate to generating an integral image after projecting computationally the information through a virtual pinhole array. We illustrate this procedure with some imaging experiments that provide microimages with enhanced quality. After projection of such microimages onto the integral-imaging monitor, 3D images are produced with great parallax and viewing angle.
NASA Technical Reports Server (NTRS)
Liu, Dahai; Goodrich, Kenneth H.; Peak, Bob
2010-01-01
This study investigated the effects of synthetic vision system (SVS) concepts and advanced flight controls on the performance of pilots flying a light, single-engine general aviation airplane. We evaluated the effects and interactions of two levels of terrain portrayal, guidance symbology, and flight control response type on pilot performance during the conduct of a relatively complex instrument approach procedure. The terrain and guidance presentations were evaluated as elements of an integrated primary flight display system. The approach procedure used in the study included a steeply descending, curved segment as might be encountered in emerging, required navigation performance (RNP) based procedures. Pilot performance measures consisted of flight technical performance, perceived workload, perceived situational awareness and subjective preference. The results revealed that an elevation based generic terrain portrayal significantly improved perceived situation awareness without adversely affecting flight technical performance or workload. Other factors (pilot instrument rating, control response type, and guidance symbology) were not found to significantly affect the performance measures.
A Flexible Evolvable Architecture for Constellation Mission Systems User Applications
NASA Technical Reports Server (NTRS)
Trimble, Jay P.; Crocker, Alan R.
2008-01-01
While simulating a complex set of repair tasks to be performed by EVA crewmembers on an upcoming mission, flight controllers and astronauts determine that the repair will take much longer than originally anticipated. All equipment in the vicinity of the worksite must be powered off to maintain a safe environment for the astronauts. Because heater power will be unavailable, several critical components will now be at risk of freezing and permanent damage. If an impending thermal violation is detected, Mission Control will have very limited time to react. Therefore, flight controllers must not only modify their procedures to account for these risks, they must also incorporate into their displays outputs from thermal models, alternate temperature measurements, new alarm limits, and emergency power-on commands to enable the detection and response to freezing conditions. Current software for mission control systems makes scenarios like this difficult to address. Given the time frame for modifying software, operations teams are left with labor-intensive operational workarounds as their only options. NASA Ames Research Center (ARC) and NASA Johnson Space Center (JSC) are collaborating on the development of a flexible software system for mission operations that will enable greater user flexibility than has been available to date. Using composable software, end users in the scenario described above could recompose procedures and command and control displays to allow flight controllers to monitor temperature measurements, identify time-critical conditions, and execute the procedures required to respond to these conditions before flight hardware is permanently damaged.
Three-dimensional displays and stereo vision
Westheimer, Gerald
2011-01-01
Procedures for three-dimensional image reconstruction that are based on the optical and neural apparatus of human stereoscopic vision have to be designed to work in conjunction with it. The principal methods of implementing stereo displays are described. Properties of the human visual system are outlined as they relate to depth discrimination capabilities and achieving optimal performance in stereo tasks. The concept of depth rendition is introduced to define the change in the parameters of three-dimensional configurations for cases in which the physical disposition of the stereo camera with respect to the viewed object differs from that of the observer's eyes. PMID:21490023
Assaraf, Roland
2014-12-01
We show that the recently proposed correlated sampling without reweighting procedure extends the locality (asymptotic independence of the system size) of a physical property to the statistical fluctuations of its estimator. This makes the approach potentially vastly more efficient for computing space-localized properties in large systems compared with standard correlated methods. A proof is given for a large collection of noninteracting fragments. Calculations on hydrogen chains suggest that this behavior holds not only for systems displaying short-range correlations, but also for systems with long-range correlations.
Improvements to the fastex flutter analysis computer code
NASA Technical Reports Server (NTRS)
Taylor, Ronald F.
1987-01-01
Modifications to the FASTEX flutter analysis computer code (UDFASTEX) are described. The objectives were to increase the problem size capacity of FASTEX, reduce run times by modification of the modal interpolation procedure, and to add new user features. All modifications to the program are operable on the VAX 11/700 series computers under the VAX operating system. Interfaces were provided to aid in the inclusion of alternate aerodynamic and flutter eigenvalue calculations. Plots can be made of the flutter velocity, display and frequency data. A preliminary capability was also developed to plot contours of unsteady pressure amplitude and phase. The relevant equations of motion, modal interpolation procedures, and control system considerations are described and software developments are summarized. Additional information documenting input instructions, procedures, and details of the plate spline algorithm is found in the appendices.
Tikunova, N V; Morozova, V V
2009-10-01
The display of peptides and proteins on the surface of filamentous bacteriophage is a powerful methodology for selection of peptides and protein domains, including antibodies. An advantage of this methodology is the direct physical link between the phenotype and the genotype, as an analyzed polypeptide and its encoding DNA fragment exist in one phage particle. Development of phage display antibody libraries provides repertoires of phage particles exposing antibody fragments of great diversity. The biopanning procedure facilitates selection of antibodies with high affinity and specificity for almost any target. This review is an introduction to phage display methodology. It presents recombinant antibodies display in more details:, construction of phage libraries of antibody fragments and different strategies for the biopanning procedure.
Designing Flight Deck Procedures
NASA Technical Reports Server (NTRS)
Degani, Asaf; Wiener, Earl
2005-01-01
Three reports address the design of flight-deck procedures and various aspects of human interaction with cockpit systems that have direct impact on flight safety. One report, On the Typography of Flight- Deck Documentation, discusses basic research about typography and the kind of information needed by designers of flight deck documentation. Flight crews reading poorly designed documentation may easily overlook a crucial item on the checklist. The report surveys and summarizes the available literature regarding the design and typographical aspects of printed material. It focuses on typographical factors such as proper typefaces, character height, use of lower- and upper-case characters, line length, and spacing. Graphical aspects such as layout, color coding, fonts, and character contrast are discussed; and several cockpit conditions such as lighting levels and glare are addressed, as well as usage factors such as angular alignment, paper quality, and colors. Most of the insights and recommendations discussed in this report are transferable to paperless cockpit systems of the future and computer-based procedure displays (e.g., "electronic flight bag") in aerospace systems and similar systems that are used in other industries such as medical, nuclear systems, maritime operations, and military systems.
X-window-based 2K display workstation
NASA Astrophysics Data System (ADS)
Weinberg, Wolfram S.; Hayrapetian, Alek S.; Cho, Paul S.; Valentino, Daniel J.; Taira, Ricky K.; Huang, H. K.
1991-07-01
A high-definition, high-performance display station for reading and review of digital radiological images is introduced. The station is based on a Sun SPARC Station 4 and employs X window system for display and manipulation of images. A mouse-operated graphic user interface is implemented utilizing Motif-style tools. The system supports up to four MegaScan gray-scale 2560 X 2048 monitors. A special configuration of frame and video buffer yields a data transfer of 50 M pixels/s. A magnetic disk array supplies a storage capacity of 2 GB with a data transfer rate of 4-6 MB/s. The system has access to the central archive through an ultrahigh-speed fiber-optic network and patient studies are automatically transferred to the local disk. The available image processing functions include change of lookup table, zoom and pan, and cine. Future enhancements will provide for manual contour tracing, length, area, and density measurements, text and graphic overlay, as well as composition of selected images. Additional preprocessing procedures under development will optimize the initial lookup table and adjust the images to a standard orientation.
2007-06-01
Social Science Research Methods. M. S. Lewis-Beck, A . Bryman and T. F. Liao. Thousand Oaks CA, SAGE. 2: 440-442. Checkland, P. (1999). Systems...E. (1948). " A Mathematical Theory of Communication." The Bell System Technical Journal 27(3): 379-423. Simon, H. A . (1962). "The Architecture of...provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently
Laser angle measurement system
NASA Technical Reports Server (NTRS)
Pond, C. R.; Texeira, P. D.; Wilbert, R. E.
1980-01-01
The design and fabrication of a laser angle measurement system is described. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the mode. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. Optical and electrical schematics, system maintenance and operation procedures are included, and the results of a demonstration test are given.
NASA Technical Reports Server (NTRS)
Rinehart, Maegan L.
2011-01-01
The purpose of this activity is to provide the Mechanical Components Test Facility (MCTF) with the capability to obtain electronic leak test and proof pressure data, Payload and Components Real-time Automated Test System (PACRATS) data acquisition software will be utilized to display real-time data. It will record leak rates and pressure/vacuum level(s) simultaneously. This added functionality will provide electronic leak test and pressure data at specified sampling frequencies. Electronically stored data will provide ES61 with increased data security, analysis, and accuracy. The tasks performed in this procedure are to verify PACRATS only, and are not intended to provide verifications for MCTF equipment.
Development of advanced acreage estimation methods
NASA Technical Reports Server (NTRS)
Guseman, L. F., Jr. (Principal Investigator)
1980-01-01
The use of the AMOEBA clustering/classification algorithm was investigated as a basis for both a color display generation technique and maximum likelihood proportion estimation procedure. An approach to analyzing large data reduction systems was formulated and an exploratory empirical study of spatial correlation in LANDSAT data was also carried out. Topics addressed include: (1) development of multiimage color images; (2) spectral spatial classification algorithm development; (3) spatial correlation studies; and (4) evaluation of data systems.
NASA Technical Reports Server (NTRS)
1985-01-01
Operational forecasters have habitually been plagued with the problems associated with acquisition, display, and dissemination of data used in preparing forecasts. The centralized storm information system (CSIS) experiment provided an operational forecaster with an interactive computer system which could perform these preliminary tasks more quickly and accurately than any human could. CSIS objectives pertaining to improved severe storms forecasting and warning procedures are addressed.
NASA Technical Reports Server (NTRS)
Adams, Catherine A.; Murdoch, Jennifer L.; Consiglio, Maria C.; WIlliams, Daniel M.
2005-01-01
One objective of the Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated Airport Management Module (AMM) and separation responsibilities to general aviation (GA) pilots. Implementation of this concept required the development of a research Multi-Function Display (MFD) to support the interactive communications between pilots and the AMM. The interface also had to accommodate traffic awareness, self-separation, and spacing tasks through dynamic messaging and symbology for flight path conformance and conflict detection and alerting (CDA). The display served as the mechanism to support the examination of the viability of executing instrument operations designed for SATS designated airports. Results of simulation and flight experiments conducted at the National Aeronautics and Space Administration's (NASA) Langley Research Center indicate that the concept, as facilitated by the research MFD, did not increase pilots subjective workload levels or reduce their situation awareness (SA). Post-test usability assessments revealed that pilots preferred using the enhanced MFD to execute flight procedures, reporting improved SA over conventional instrument flight rules (IFR) procedures.
NASA Technical Reports Server (NTRS)
Grove, R. D.; Bowles, R. L.; Mayhew, S. C.
1972-01-01
A maximum likelihood parameter estimation procedure and program were developed for the extraction of the stability and control derivatives of aircraft from flight test data. Nonlinear six-degree-of-freedom equations describing aircraft dynamics were used to derive sensitivity equations for quasilinearization. The maximum likelihood function with quasilinearization was used to derive the parameter change equations, the covariance matrices for the parameters and measurement noise, and the performance index function. The maximum likelihood estimator was mechanized into an iterative estimation procedure utilizing a real time digital computer and graphic display system. This program was developed for 8 measured state variables and 40 parameters. Test cases were conducted with simulated data for validation of the estimation procedure and program. The program was applied to a V/STOL tilt wing aircraft, a military fighter airplane, and a light single engine airplane. The particular nonlinear equations of motion, derivation of the sensitivity equations, addition of accelerations into the algorithm, operational features of the real time digital system, and test cases are described.
SAFARI, an On-Line Text-Processing System User's Manual.
ERIC Educational Resources Information Center
Chapin, P.G.; And Others.
This report describes for the potential user a set of procedures for processing textual materials on-line. In this preliminary model an information analyst can scan through messages, reports, and other documents on a display scope and select relevant facts, which are processed linguistically and then stored in the computer in the form of logical…
NASA Technical Reports Server (NTRS)
Clarke, M. M.; Garin, J.
1981-01-01
Operator perceptual cognitive styles as predictors of remote task performance were identified. Remote tasks which require the use of servo controlled master/slave manipulators and closed circuit television for teleoperator repair and maintenance of nuclear fuel recycling systems are examined. A useful procedure for identifying such perceptual styles is described.
Decision-support information system to manage mass casualty incidents at a level 1 trauma center.
Bar-El, Yaron; Tzafrir, Sara; Tzipori, Idan; Utitz, Liora; Halberthal, Michael; Beyar, Rafael; Reisner, Shimon
2013-12-01
Mass casualty incidents are probably the greatest challenge to a hospital. When such an event occurs, hospitals are required to instantly switch from their routine activity to conditions of great uncertainty and confront needs that exceed resources. We describe an information system that was uniquely designed for managing mass casualty events. The web-based system is activated when a mass casualty event is declared; it displays relevant operating procedures, checklists, and a log book. The system automatically or semiautomatically initiates phone calls and public address announcements. It collects real-time data from computerized clinical and administrative systems in the hospital, and presents them to the managing team in a clear graphic display. It also generates periodic reports and summaries of available or scarce resources that are sent to predefined recipients. When the system was tested in a nationwide exercise, it proved to be an invaluable tool for informed decision making in demanding and overwhelming situations such as mass casualty events.
A review of wiring system safety in space power systems
NASA Technical Reports Server (NTRS)
Stavnes, Mark W.; Hammoud, Ahmad N.
1993-01-01
Wiring system failures have resulted from arc propagation in the wiring harnesses of current aerospace vehicles. These failures occur when the insulation becomes conductive upon the initiation of an arc. In some cases, the conductive path of the carbon arc track displays a high enough resistance such that the current is limited, and therefore may be difficult to detect using conventional circuit protection. Often, such wiring failures are not simply the result of insulation failure, but are due to a combination of wiring system factors. Inadequate circuit protection, unforgiving system designs, and careless maintenance procedures can contribute to a wiring system failure. This paper approaches the problem with respect to the overall wiring system, in order to determine what steps can be taken to improve the reliability, maintainability, and safety of space power systems. Power system technologies, system designs, and maintenance procedures which have led to past wiring system failures will be discussed. New technologies, design processes, and management techniques which may lead to improved wiring system safety will be introduced.
An integrated port camera and display system for laparoscopy.
Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E
2010-05-01
In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.
Video integrated measurement system. [Diagnostic display devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spector, B.; Eilbert, L.; Finando, S.
A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides anmore » innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.« less
Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R
2012-08-01
A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.
A Computer Program for Displaying Forest Survey Type Information
B. Bruce Bare; Robert N. Stone
1968-01-01
Presents a computerized procedure for displaying forest type information from inventory plots. Although the development of general forest type maps in emphasized, the program can be used to display any locational data having rectangular coordinates
Klooster, Nathaniel B.; Cook, Susan W.; Uc, Ergun Y.; Duff, Melissa C.
2015-01-01
Hand gesture, a ubiquitous feature of human interaction, facilitates communication. Gesture also facilitates new learning, benefiting speakers and listeners alike. Thus, gestures must impact cognition beyond simply supporting the expression of already-formed ideas. However, the cognitive and neural mechanisms supporting the effects of gesture on learning and memory are largely unknown. We hypothesized that gesture's ability to drive new learning is supported by procedural memory and that procedural memory deficits will disrupt gesture production and comprehension. We tested this proposal in patients with intact declarative memory, but impaired procedural memory as a consequence of Parkinson's disease (PD), and healthy comparison participants with intact declarative and procedural memory. In separate experiments, we manipulated the gestures participants saw and produced in a Tower of Hanoi (TOH) paradigm. In the first experiment, participants solved the task either on a physical board, requiring high arching movements to manipulate the discs from peg to peg, or on a computer, requiring only flat, sideways movements of the mouse. When explaining the task, healthy participants with intact procedural memory displayed evidence of their previous experience in their gestures, producing higher, more arching hand gestures after solving on a physical board, and smaller, flatter gestures after solving on a computer. In the second experiment, healthy participants who saw high arching hand gestures in an explanation prior to solving the task subsequently moved the mouse with significantly higher curvature than those who saw smaller, flatter gestures prior to solving the task. These patterns were absent in both gesture production and comprehension experiments in patients with procedural memory impairment. These findings suggest that the procedural memory system supports the ability of gesture to drive new learning. PMID:25628556
Zar, Harvey A; Noe, Frances E; Szalados, James E; Goodrich, Michael D; Busby, Michael G
2002-01-01
A repetitive graphic display of the single breath pulmonary function can indicate changes in cardiac and pulmonary physiology brought on by clinical events. Parallel advances in computer technology and monitoring make real-time, single breath pulmonary function clinically practicable. We describe a system built from a commercially available airway gas monitor and off the shelf computer and data-acquisition hardware. Analog data for gas flow rate, O2, and CO2 concentrations are introduced into a computer through an analog-to-digital conversion board. Oxygen uptake (VO2) and carbon dioxide output (VCO2) are calculated for each breath. Inspired minus expired concentrations for O2 and CO2 are displayed simultaneously with the expired gas flow rate curve for each breath. Dead-space and alveolar ventilation are calculated for each breath and readily appreciated from the display. Graphs illustrating the function of the system are presented for the following clinical scenarios; upper airway obstruction, bronchospasm, bronchopleural fistula, pulmonary perfusion changes and inadequate oxygen delivery. This paper describes a real-time, single breath pulmonary monitoring system that displays three parameters graphed against time: expired flow rate, oxygen uptake and carbon dioxide production. This system allows for early and rapid recognition of treatable conditions that may lead to adverse events without any additional patient measurements or invasive procedures. Monitoring systems similar to the one described in this paper may lead to a higher level of patient safety without any additional patient risk.
Procedures for woody vegetation surveys in the Kazgail rural council area, Kordofan, Sudan
Falconer, Allan; Cross, Matthew D.; Orr, Donald G.
1990-01-01
Efforts to reforest parts of the Kordofan Province of Sudan are receiving support from international development agencies. These efforts include planning and implementing reforestation activities that require the collection of natural resources and socioeconomic data, and the preparation of base maps. A combination of remote sensing, geographic information system and global positioning systems procedures are used in this study to meet these requirements.Remote sensing techniques were used to provide base maps and to guide the compilation of vegetation resources maps. These techniques provided a rapid and efficient method for documenting available resources. Pocket‐sized global positioning system units were used to establish the location of field data collected for mapping and resource analysis. A microcomputer data management system tabulated and displayed the field data. The resulting system for data analysis, management, and planning has been adopted for the mapping and inventory of the Gum Belt of Sudan.
Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo
2016-02-01
Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.
ATC simulation of helicopter IFR approaches into major terminal areas using RNAV, MLS, and CDTI
NASA Technical Reports Server (NTRS)
Tobias, L.; Lee, H. Q.; Peach, L. L.; Willett, F. M., Jr.; Obrien, P. J.
1981-01-01
The introduction of independent helicopter IFR routes at hub airports was investigated in a real time air traffic control system simulation involving a piloted helicopter simulator, computer generated air traffic, and air traffic controllers. The helicopter simulator was equipped to fly area navigation (RNAV) routes and microwave landing system approaches. Problems studied included: (1) pilot acceptance of the approach procedure and tracking accuracy; (2) ATC procedures for handling a mix of helicopter and fixed wing traffic; and (3) utility of the cockpit display of traffic information (CDTI) for the helicopter in the hub airport environment. Results indicate that the helicopter routes were acceptable to the subject pilots and were noninterfering with fixed wing traffic. Merging and spacing maneuvers using CDTI were successfully carried out by the pilots, but controllers had some reservations concerning the acceptability of the CDTI procedures.
Computer-aided boundary delineation of agricultural lands
NASA Technical Reports Server (NTRS)
Cheng, Thomas D.; Angelici, Gary L.; Slye, Robert E.; Ma, Matt
1989-01-01
The National Agricultural Statistics Service of the United States Department of Agriculture (USDA) presently uses labor-intensive aerial photographic interpretation techniques to divide large geographical areas into manageable-sized units for estimating domestic crop and livestock production. Prototype software, the computer-aided stratification (CAS) system, was developed to automate the procedure, and currently runs on a Sun-based image processing system. With a background display of LANDSAT Thematic Mapper and United States Geological Survey Digital Line Graph data, the operator uses a cursor to delineate agricultural areas, called sampling units, which are assigned to strata of land-use and land-cover types. The resultant stratified sampling units are used as input into subsequent USDA sampling procedures. As a test, three counties in Missouri were chosen for application of the CAS procedures. Subsequent analysis indicates that CAS was five times faster in creating sampling units than the manual techniques were.
NASA Technical Reports Server (NTRS)
Pond, C. R.; Texeira, P. D.
1985-01-01
A laser angle measurement system was designed and fabricated for NASA Langley Research Center. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the model. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. This report includes optical and electrical schematics, system maintenance and operation procedures.
Thermal enclosure system functional simulation user's manual
NASA Technical Reports Server (NTRS)
Morris, A. Terry
1994-01-01
A form and function simulation of the thermal enclosure system (TES) for a microgravity protein crystal growth experiment has been developed as part of an investigation of the benefits and limitations of intravehicular telerobotics to aid in microgravity science and production. A user can specify the time, temperature, and sample rate profile for a given experiment, and menu options and status are presented on an LCD display. This report describes the features and operational procedures for the functional simulation.
NASA Technical Reports Server (NTRS)
Bartolone, Anthony; Trujillo, Anna
2002-01-01
NASA Langley Research Center has been researching ways to improve flight crew decision aiding for systems management. Our current investigation is how to display a wide variety of aircraft parameters in ways that will improve the flight crew's situation awareness. To accomplish this, new means are being explored that will monitor the overall health of a flight and report the current status of the aircraft and forecast impending problems to the pilots. The initial step in this research was to conduct a survey addressing how current glass-cockpit commercial pilots would value a prediction of the status of critical aircraft systems. We also addressed how this new type of data ought to be conveyed and utilized. Therefore, two other items associated with predictive information were also included in the survey. The first addressed the need for system status, alerts and procedures, and system controls to be more logically grouped together, or collocated, on the flight deck. The second idea called for the survey respondents opinions on the functionality of mission status graphics; a display methodology that groups a variety of parameters onto a single display that can instantaneously convey a complete overview of both an aircraft's system and mission health.
Development of a GIS interface for WEPP Model application to Great Lakes forested watersheds
J. R. Frankenberger; S. Dun; D. C. Flanagan; J. Q. Wu; W. J. Elliot
2011-01-01
This presentation will highlight efforts on development of a new online WEPP GIS interface, targeted toward application in forested regions bordering the Great Lakes. The key components and algorithms of the online GIS system will be outlined. The general procedures used to provide input to the WEPP model and to display model output will be demonstrated.
Mantovani, Matheus Bortoluzzi; Souza, Eduardo Clemente; Marson, Fabiano Carlos; Corrêa, Giovani Oliveira; Progiante, Patrícia Saram; Silva, Cléverson Oliveira
2016-01-01
Excessive gingival display during smile can result in compromised esthetics. This study aims to report a case of excessive gingival display with multiple etiologies treated by means of modified lip repositioning technique associated with esthetic crown lengthening. A 23-year-old female patient, with 5-mm gingival display during smile caused by altered passive eruption and hypermobility of the upper lip, underwent the modified lip repositioning technique associated with gingivectomy followed by flap elevation and ostectomy/osteoplasty. Seven months after the second procedure, the patient had her esthetic complaint solved appearing stable in the observation period. The modified lip repositioning technique is an effective procedure employed to reduce gingival display and when associated with esthetic clinical crown lengthening, can appropriately treat cases of gummy smile. PMID:27041845
3D brain MR angiography displayed by a multi-autostereoscopic screen
NASA Astrophysics Data System (ADS)
Magalhães, Daniel S. F.; Ribeiro, Fádua H.; Lima, Fabrício O.; Serra, Rolando L.; Moreno, Alfredo B.; Li, Li M.
2012-02-01
The magnetic resonance angiography (MRA) can be used to examine blood vessels in key areas of the body, including the brain. In the MRA, a powerful magnetic field, radio waves and a computer produce the detailed images. Physicians use the procedure in brain images mainly to detect atherosclerosis disease in the carotid artery of the neck, which may limit blood flow to the brain and cause a stroke and identify a small aneurysm or arteriovenous malformation inside the brain. Multi-autostereoscopic displays provide multiple views of the same scene, rather than just two, as in autostereoscopic systems. Each view is visible from a different range of positions in front of the display. This allows the viewer to move left-right in front of the display and see the correct view from any position. The use of 3D imaging in the medical field has proven to be a benefit to doctors when diagnosing patients. For different medical domains a stereoscopic display could be advantageous in terms of a better spatial understanding of anatomical structures, better perception of ambiguous anatomical structures, better performance of tasks that require high level of dexterity, increased learning performance, and improved communication with patients or between doctors. In this work we describe a multi-autostereoscopic system and how to produce 3D MRA images to be displayed with it. We show results of brain MR angiography images discussing, how a 3D visualization can help physicians to a better diagnosis.
Development of a microportable imaging system for otoscopy and nasoendoscopy evaluations.
VanLue, Michael; Cox, Kenneth M; Wade, James M; Tapp, Kevin; Linville, Raymond; Cosmato, Charlie; Smith, Tom
2007-03-01
Imaging systems for patients with cleft palate typically are not portable, but are essential to obtain an audiovisual record of nasoendoscopy and otoscopy procedures. Practitioners who evaluate patients in rural, remote, or otherwise medically underserved areas are expected to obtain audiovisual recordings of these procedures as part of standard clinical practice. Therefore, patients must travel substantial distances to medical facilities that have standard recording equipment. This project describes the specific components, strengths and weaknesses of an MPEG-4 digital recording system for otoscopy/nasoendoscopy evaluation of patients with cleft palate that is both portable and compatible with store-and-forward telemedicine applications. Three digital recording configurations (TabletPC, handheld digital video recorder, and an 8-mm digital camcorder) were used to record the audio/ video signal from an analog video scope system. The handheld digital video recorder was most effective at capturing audio/video and displaying procedures in real time. The system described was particularly easy to use, because it required no postrecording file capture or compression for later review, transfer, and/or archiving. The handheld digital recording system was assembled from commercially available components. The portability and the telemedicine compatibility of the handheld digital video recorder offers a viable solution for the documentation of nasoendosocopy and otoscopy procedures in remote, rural, or other locations where reduced medical access precludes the use of larger component audio/video systems.
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Hansman, R. John
1997-01-01
Efforts to increase airport capacity include studies of aircraft systems that would enable simultaneous approaches to closely spaced parallel runway in Instrument Meteorological Conditions (IMC). The time-critical nature of a parallel approach results in key design issues for current and future collision avoidance systems. Two part-task flight simulator studies have examined the procedural and display issues inherent in such a time-critical task, the interaction of the pilot with a collision avoidance system, and the alerting criteria and avoidance maneuvers preferred by subjects.
Rahbarnia, Leila; Farajnia, Safar; Babaei, Hossein; Majidi, Jafar; Veisi, Kamal; Tanomand, Asghar; Akbari, Bahman
2016-11-01
Phage display is a prominent screening technique for development of novel high affinity antibodies against almost any antigen. However, removing false positive clones in screening process remains a challenge. The aim of this study was to develop an efficient and rapid method for isolation of high affinity scFvs by removing NSBs without losing rare specific clones. Therefore, a novel two rounds strategy called invert biopanning was developed for isolating high affinity scFvs against EGFRvIII antigen from human scFv library. The efficiency of invert biopanning method (procedure III) was analyzed by comparing with results of conventional biopanning methods (procedures I and II). According to the results of polyclonal ELISA, the second round of procedure III displayed highest binding affinity against EGFRvIII peptide accompanied by lowest NSB comparing to other two procedures. Several positive clones were identified among output phages of procedure III by monoclonal phage ELISA which displayed high affinity to EGFRvIII antigen. In conclusion, results of our study indicate that invert biopanning is an efficient method for avoiding NSBs and conservation of rare specific clones during screening of a scFv phage library. Novel anti EGFRvIII scFv isolated could be a promising candidate for potential use in treatment of EGFRvIII expressing cancers. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Use of geographic information system to display water-quality data from San Juan basin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thorn, C.R.; Dam, W.L.
1989-09-01
The ARC/INFO geographic information system is creating thematic maps of the San Juan basin as part of the USGS Regional Aquifer-System Analysis program. (Use of trade names is for descriptive purposes only and does not constitute endorsement by the US Geological Survey.) Maps created by a Prime version of ARC/INFO, to be published in a series of Hydrologic Investigations Atlas reports for selected geologic units, will include outcrop patters, water-well locations, and water-quality data. The San Juan basin study area, encompassing about 19,400 mi{sup 2}, can be displayed with ARC/INFO at various scales; on the same scale, generated water-quality mapsmore » can be compared and overlain with other maps such as potentiometric surface and depth to top of a geologic or hydrologic unit. Selected water-quality and well data (including latitude and longitude) are retrieved from the USGS National Water Information System data base for a specified geologic unit. Data are formatted by Fortran programs and read into an INFO data base. Two parallel files - an INFO file containing water-quality data and well data and an ARC file containing the site coordinates - are joined to form the ARC/INFO data base. A file containing a series of commands using Prime's Command Procedure language is used to select coverage, display, and position data on the map. Data interpretation is enhanced by displaying water-quality data throughout the basin in combination with other hydrologic and geologic data.« less
Simultaneous real-time data collection methods
NASA Technical Reports Server (NTRS)
Klincsek, Thomas
1992-01-01
This paper describes the development of electronic test equipment which executes, supervises, and reports on various tests. This validation process uses computers to analyze test results and report conclusions. The test equipment consists of an electronics component and the data collection and reporting unit. The PC software, display screens, and real-time data-base are described. Pass-fail procedures and data replay are discussed. The OS2 operating system and Presentation Manager user interface system were used to create a highly interactive automated system. The system outputs are hardcopy printouts and MS DOS format files which may be used as input for other PC programs.
Vasan, S N Swetadri; Ionita, Ciprian N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S
2012-02-23
We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.
NASA Technical Reports Server (NTRS)
Generazio, Edward R.
2014-01-01
Unknown risks are introduced into failure critical systems when probability of detection (POD) capabilities are accepted without a complete understanding of the statistical method applied and the interpretation of the statistical results. The presence of this risk in the nondestructive evaluation (NDE) community is revealed in common statements about POD. These statements are often interpreted in a variety of ways and therefore, the very existence of the statements identifies the need for a more comprehensive understanding of POD methodologies. Statistical methodologies have data requirements to be met, procedures to be followed, and requirements for validation or demonstration of adequacy of the POD estimates. Risks are further enhanced due to the wide range of statistical methodologies used for determining the POD capability. Receiver/Relative Operating Characteristics (ROC) Display, simple binomial, logistic regression, and Bayes' rule POD methodologies are widely used in determining POD capability. This work focuses on Hit-Miss data to reveal the framework of the interrelationships between Receiver/Relative Operating Characteristics Display, simple binomial, logistic regression, and Bayes' Rule methodologies as they are applied to POD. Knowledge of these interrelationships leads to an intuitive and global understanding of the statistical data, procedural and validation requirements for establishing credible POD estimates.
Staff Radiation Doses in a Real-Time Display Inside the Angiography Room
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Roberto, E-mail: rmsanchez.hcsc@salud.madrid.org; Vano, E.; Fernandez, J. M.
MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operatormore » exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.« less
Procedural error monitoring and smart checklists
NASA Technical Reports Server (NTRS)
Palmer, Everett
1990-01-01
Human beings make and usually detect errors routinely. The same mental processes that allow humans to cope with novel problems can also lead to error. Bill Rouse has argued that errors are not inherently bad but their consequences may be. He proposes the development of error-tolerant systems that detect errors and take steps to prevent the consequences of the error from occurring. Research should be done on self and automatic detection of random and unanticipated errors. For self detection, displays should be developed that make the consequences of errors immediately apparent. For example, electronic map displays graphically show the consequences of horizontal flight plan entry errors. Vertical profile displays should be developed to make apparent vertical flight planning errors. Other concepts such as energy circles could also help the crew detect gross flight planning errors. For automatic detection, systems should be developed that can track pilot activity, infer pilot intent and inform the crew of potential errors before their consequences are realized. Systems that perform a reasonableness check on flight plan modifications by checking route length and magnitude of course changes are simple examples. Another example would be a system that checked the aircraft's planned altitude against a data base of world terrain elevations. Information is given in viewgraph form.
DEC Ada interface to Screen Management Guidelines (SMG)
NASA Technical Reports Server (NTRS)
Laomanachareon, Somsak; Lekkos, Anthony A.
1986-01-01
DEC's Screen Management Guidelines are the Run-Time Library procedures that perform terminal-independent screen management functions on a VT100-class terminal. These procedures assist users in designing, composing, and keeping track of complex images on a video screen. There are three fundamental elements in the screen management model: the pasteboard, the virtual display, and the virtual keyboard. The pasteboard is like a two-dimensional area on which a user places and manipulates screen displays. The virtual display is a rectangular part of the terminal screen to which a program writes data with procedure calls. The virtual keyboard is a logical structure for input operation associated with a physical keyboard. SMG can be called by all major VAX languages. Through Ada, predefined language Pragmas are used to interface with SMG. These features and elements of SMG are briefly discussed.
Effectively Transforming IMC Flight into VMC Flight: An SVS Case Study
NASA Technical Reports Server (NTRS)
Glaab, Louis J.; Hughes, Monic F.; Parrish, Russell V.; Takallu, Mohammad A.
2006-01-01
A flight-test experiment was conducted using the NASA LaRC Cessna 206 aircraft. Four primary flight and navigation display concepts, including baseline and Synthetic Vision System (SVS) concepts, were evaluated in the local area of Roanoke Virginia Airport, flying visual and instrument approach procedures. A total of 19 pilots, from 3 pilot groups reflecting the diverse piloting skills of the GA population, served as evaluation pilots. Multi-variable Discriminant Analysis was applied to three carefully selected and markedly different operating conditions with conventional instrumentation to provide an extension of traditional analysis methods as well as provide an assessment of the effectiveness of SVS displays to effectively transform IMC flight into VMC flight.
NASA Technical Reports Server (NTRS)
Oishi, Meeko; Tomlin, Claire; Degani, Asaf
2003-01-01
Human interaction with complex hybrid systems involves the user, the automation's discrete mode logic, and the underlying continuous dynamics of the physical system. Often the user-interface of such systems displays a reduced set of information about the entire system. In safety-critical systems, how can we identify user-interface designs which do not have adequate information, or which may confuse the user? Here we describe a methodology, based on hybrid system analysis, to verify that a user-interface contains information necessary to safely complete a desired procedure or task. Verification within a hybrid framework allows us to account for the continuous dynamics underlying the simple, discrete representations displayed to the user. We provide two examples: a car traveling through a yellow light at an intersection and an aircraft autopilot in a landing/go-around maneuver. The examples demonstrate the general nature of this methodology, which is applicable to hybrid systems (not fully automated) which have operational constraints we can pose in terms of safety. This methodology differs from existing work in hybrid system verification in that we directly account for the user's interactions with the system.
NASA Astrophysics Data System (ADS)
Suryono, T. J.; Gofuku, A.
2018-02-01
One of the important thing in the mitigation of accidents in nuclear power plant accidents is time management. The accidents should be resolved as soon as possible in order to prevent the core melting and the release of radioactive material to the environment. In this case, operators should follow the emergency operating procedure related with the accident, in step by step order and in allowable time. Nowadays, the advanced main control rooms are equipped with computer-based procedures (CBPs) which is make it easier for operators to do their tasks of monitoring and controlling the reactor. However, most of the CBPs do not include the time remaining display feature which informs operators of time available for them to execute procedure steps and warns them if the they reach the time limit. Furthermore, the feature will increase the awareness of operators about their current situation in the procedure. This paper investigates this issue. The simplified of emergency operating procedure (EOP) of steam generator tube rupture (SGTR) accident of PWR plant is applied. In addition, the sequence of actions on each step of the procedure is modelled using multilevel flow modelling (MFM) and influenced propagation rule. The prediction of action time on each step is acquired based on similar case accidents and the Support Vector Regression. The derived time will be processed and then displayed on a CBP user interface.
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Baggerman, Susan; Byrne, Vicky
2004-01-01
With the advent of the ISS and the experience of Russian, European, and US crewmembers on Mir, the importance of the psychological element in long duration missions is increasingly recognized. An integrated imagery system or Magic Window System could enhance the habitability, performance, and productivity for long term stays in space. Because this is type of system is a new concept for space, functional and technical requirements need to be determined. As part of a three-year project, the functional and technical requirements for an Imagery System onboard the International Space Station (ISS) have been explored. Valuable information was gathered from a survey completed by participants that had been in analog environments (remote/isolated) such as Antarctica, Aquarius, ISS crewmember debriefs, and crew support meetings to identify key functions desired for an integrated Magic Window System. Exercise and medical care activities were identified as areas that could benefit from such a system. It was determined that for exercise, it was worth exploring the concept of displaying a dynamic screen that changes as the crewmember's speed changes while showing physiological measures in a combined display. In terms of enhancing the interfaces for medical care activities, the Magic Window System could show video clips along side procedures for just-in-time training scenarios through a heads-up display. In addition, the portability, usability, and reliability were stressed as important considerations for an integrated system of technologies or Magic Window System. In addition, a review of state-of-the-art screens and other existing technologies such as tablet PCs and Personal Digital Assistants (PDAs) was conducted and contributed to defining technical requirements and feasibility of systems. Some heuristic evaluations of large displays and PDAs were conducted. Finally, feasibility for implementation onboard ISS has been considered. Currently, specific headset units are undergoing usability testing. The outcome of these activities will be valuable to determine the best candidates for an integrated system that could accommodate different needs depending on task.
Integrated intelligent systems in advanced reactor control rooms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckmeyer, R.R.
1989-01-01
An intelligent, reactor control room, information system is designed to be an integral part of an advanced control room and will assist the reactor operator's decision making process by continuously monitoring the current plant state and providing recommended operator actions to improve that state. This intelligent system is an integral part of, as well as an extension to, the plant protection and control systems. This paper describes the interaction of several functional components (intelligent information data display, technical specifications monitoring, and dynamic procedures) of the overall system and the artificial intelligence laboratory environment assembled for testing the prototype. 10 refs.,more » 5 figs.« less
Pilot Task Profiles, Human Factors, And Image Realism
NASA Astrophysics Data System (ADS)
McCormick, Dennis
1982-06-01
Computer Image Generation (CIG) visual systems provide real time scenes for state-of-the-art flight training simulators. The visual system reauires a greater understanding of training tasks, human factors, and the concept of image realism to produce an effective and efficient training scene than is required by other types of visual systems. Image realism must be defined in terms of pilot visual information reauirements. Human factors analysis of training and perception is necessary to determine the pilot's information requirements. System analysis then determines how the CIG and display device can best provide essential information to the pilot. This analysis procedure ensures optimum training effectiveness and system performance.
Chien, Alyna T; Lehmann, Lisa Soleymani; Hatfield, Laura A; Koplan, Kate E; Petty, Carter R; Sinaiko, Anna D; Rosenthal, Meredith B; Sequist, Thomas D
2017-04-01
Prior studies have demonstrated how price transparency lowers the test-ordering rates of trainees in hospitals, and physician-targeted price transparency efforts have been viewed as a promising cost-controlling strategy. To examine the effect of displaying paid-price information on test-ordering rates for common imaging studies and procedures within an accountable care organization (ACO). Block randomized controlled trial for 1 year. A total of 1205 fully licensed clinicians (728 primary care, 477 specialists). Starting January 2014, clinicians in the Control arm received no price display; those in the intervention arms received Single or Paired Internal/External Median Prices in the test-ordering screen of their electronic health record. Internal prices were the amounts paid by insurers for the ACO's services; external paid prices were the amounts paid by insurers for the same services when delivered by unaffiliated providers. Ordering rates (orders per 100 face-to-face encounters with adult patients): overall, designated to be completed internally within the ACO, considered "inappropriate" (e.g., MRI for simple headache), and thought to be "appropriate" (e.g., screening colonoscopy). We found no significant difference in overall ordering rates across the Control, Single Median Price, or Paired Internal/External Median Prices study arms. For every 100 encounters, clinicians in the Control arm ordered 15.0 (SD 31.1) tests, those in the Single Median Price arm ordered 15.0 (SD 16.2) tests, and those in the Paired Prices arms ordered 15.7 (SD 20.5) tests (one-way ANOVA p-value 0.88). There was no difference in ordering rates for tests designated to be completed internally or considered to be inappropriate or appropriate. Displaying paid-price information did not alter how frequently primary care and specialist clinicians ordered imaging studies and procedures within an ACO. Those with a particular interest in removing waste from the health care system may want to consider a variety of contextual factors that can affect physician-targeted price transparency.
[First clinical experience with extended planning and navigation in an interventional MRI unit].
Moche, M; Schmitgen, A; Schneider, J P; Bublat, M; Schulz, T; Voerkel, C; Trantakis, C; Bennek, J; Kahn, T; Busse, H
2004-07-01
To present an advanced concept for patient-based navigation and to report on our first clinical experience with interventions in the cranium, of soft-tissue structures (breast, liver) and in the musculoskeletal system. A PC-based navigation system was integrated into an existing interventional MRI environment. Intraoperatively acquired 3D data were used for interventional planning. The information content of these reference data was increased by integration of additional image modalities (e. g., fMRI, CT) and by color display of areas with early contrast media enhancement. Within 18 months, the system was used in 123 patients undergoing interventions in different anatomic regions (brain: 64, paranasal sinus: 9, breast: 20, liver: 17, bone: 9, muscle: 4). The mean duration of 64 brain interventions was compared with that of 36 procedures using the scanner's standard navigation. In contrast with the continuous scanning mode of the MR system (0.25 fps), the higher quality as well as the real time display (4 fps) of the MR images reconstructed from the 3D reference data allowed adequate hand-eye coordination. With our system, patient movement and tissue shifts could be immediately detected intraoperatively, and, in contrast to the standard procedure, navigation safely resumed after updating the reference data. The navigation system was characterized by good stability, efficient system integration and easy usability. Despite additional working steps still to be optimized, the duration of the image-guided brain tumor resections was not significantly longer. The presented system combines the advantage of intraoperative MRI with established visualization, planning, and real time capabilities of neuronavigation and can be efficiently applied in a broad range of non-neurosurgical interventions.
NASA Astrophysics Data System (ADS)
Ferreira, Flávio P.; Forte, Paulo M. F.; Felgueiras, Paulo E. R.; Bret, Boris P. J.; Belsley, Michael S.; Nunes-Pereira, Eduardo J.
2017-02-01
An Automatic Optical Inspection (AOI) system for optical inspection of imaging devices used in automotive industry using an inspecting optics of lower spatial resolution than the device under inspection is described. This system is robust and with no moving parts. The cycle time is small. Its main advantage is that it is capable of detecting and quantifying defects in regular patterns, working below the Shannon-Nyquist criterion for optical resolution, using a single low resolution image sensor. It is easily scalable, which is an important advantage in industrial applications, since the same inspecting sensor can be reused for increasingly higher spatial resolutions of the devices to be inspected. The optical inspection is implemented with a notch multi-band Fourier filter, making the procedure especially fitted for regular patterns, like the ones that can be produced in image displays and Head Up Displays (HUDs). The regular patterns are used in production line only, for inspection purposes. For image displays, functional defects are detected at the level of a sub-image display grid element unit. Functional defects are the ones impairing the function of the display, and are preferred in AOI to the direct geometric imaging, since those are the ones directly related with the end-user experience. The shift in emphasis from geometric imaging to functional imaging is critical, since it is this that allows quantitative inspection, below Shannon-Nyquist. For HUDs, the functional detect detection addresses defects resulting from the combined effect of the image display and the image forming optics.
Intervention strategies for the management of human error
NASA Technical Reports Server (NTRS)
Wiener, Earl L.
1993-01-01
This report examines the management of human error in the cockpit. The principles probably apply as well to other applications in the aviation realm (e.g. air traffic control, dispatch, weather, etc.) as well as other high-risk systems outside of aviation (e.g. shipping, high-technology medical procedures, military operations, nuclear power production). Management of human error is distinguished from error prevention. It is a more encompassing term, which includes not only the prevention of error, but also a means of disallowing an error, once made, from adversely affecting system output. Such techniques include: traditional human factors engineering, improvement of feedback and feedforward of information from system to crew, 'error-evident' displays which make erroneous input more obvious to the crew, trapping of errors within a system, goal-sharing between humans and machines (also called 'intent-driven' systems), paperwork management, and behaviorally based approaches, including procedures, standardization, checklist design, training, cockpit resource management, etc. Fifteen guidelines for the design and implementation of intervention strategies are included.
Samosky, Joseph T; Baillargeon, Emma; Bregman, Russell; Brown, Andrew; Chaya, Amy; Enders, Leah; Nelson, Douglas A; Robinson, Evan; Sukits, Alison L; Weaver, Robert A
2011-01-01
We have developed a prototype of a real-time, interactive projective overlay (IPO) system that creates augmented reality display of a medical procedure directly on the surface of a full-body mannequin human simulator. These images approximate the appearance of both anatomic structures and instrument activity occurring within the body. The key innovation of the current work is sensing the position and motion of an actual device (such as an endotracheal tube) inserted into the mannequin and using the sensed position to control projected video images portraying the internal appearance of the same devices and relevant anatomic structures. The images are projected in correct registration onto the surface of the simulated body. As an initial practical prototype to test this technique we have developed a system permitting real-time visualization of the intra-airway position of an endotracheal tube during simulated intubation training.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonzalez Anez, Francisco
This paper presents two development projects (STARMATE and VIRMAN) focused on supporting training on maintenance. Both projects aim at specifying, designing, developing, and demonstrating prototypes allowing computer guided maintenance of complex mechanical elements using Augmented and Virtual Reality techniques. VIRMAN is a Spanish development project. The objective is to create a computer tool for maintenance training course elaborations and training delivery based on 3D virtual reality models of complex components. The training delivery includes 3D record displays on maintenance procedures with all complementary information for intervention understanding. Users are requested to perform the maintenance intervention trying to follow up themore » procedure. Users can be evaluated about the level of knowledge achieved. Instructors can check the evaluation records left during the training sessions. VIRMAN is simple software supported by a regular computer and can be used in an Internet framework. STARMATE is a forward step in the area of virtual reality. STARMATE is a European Commission project in the frame of 'Information Societies Technologies'. A consortium of five companies and one research institute shares their expertise in this new technology. STARMATE provides two main functionalities (1) user assistance for achieving assembly/de-assembly and following maintenance procedures, and (2) workforce training. The project relies on Augmented Reality techniques, which is a growing area in Virtual Reality research. The idea of Augmented Reality is to combine a real scene, viewed by the user, with a virtual scene, generated by a computer, augmenting the reality with additional information. The user interface is see-through goggles, headphones, microphone and an optical tracking system. All these devices are integrated in a helmet connected with two regular computers. The user has his hands free for performing the maintenance intervention and he can navigate in the virtual world thanks to a voice recognition system and a virtual pointing device. The maintenance work is guided with audio instructions, 2D and 3D information are directly displayed into the user's goggles: There is a position-tracking system that allows 3D virtual models to be displayed in the real counterpart positions independently of the user allocation. The user can create his own virtual environment, placing the information required wherever he wants. The STARMATE system is applicable to a large variety of real work situations. (author)« less
New procedures to evaluate visually lossless compression for display systems
NASA Astrophysics Data System (ADS)
Stolitzka, Dale F.; Schelkens, Peter; Bruylants, Tim
2017-09-01
Visually lossless image coding in isochronous display streaming or plesiochronous networks reduces link complexity and power consumption and increases available link bandwidth. A new set of codecs developed within the last four years promise a new level of coding quality, but require new techniques that are sufficiently sensitive to the small artifacts or color variations induced by this new breed of codecs. This paper begins with a summary of the new ISO/IEC 29170-2, a procedure for evaluation of lossless coding and reports the new work by JPEG to extend the procedure in two important ways, for HDR content and for evaluating the differences between still images, panning images and image sequences. ISO/IEC 29170-2 relies on processing test images through a well-defined process chain for subjective, forced-choice psychophysical experiments. The procedure sets an acceptable quality level equal to one just noticeable difference. Traditional image and video coding evaluation techniques, such as, those used for television evaluation have not proven sufficiently sensitive to the small artifacts that may be induced by this breed of codecs. In 2015, JPEG received new requirements to expand evaluation of visually lossless coding for high dynamic range images, slowly moving images, i.e., panning, and image sequences. These requirements are the basis for new amendments of the ISO/IEC 29170-2 procedures described in this paper. These amendments promise to be highly useful for the new content in television and cinema mezzanine networks. The amendments passed the final ballot in April 2017 and are on track to be published in 2018.
A pilot's opinion - VTOL control design requirements for the instrument approach task.
NASA Technical Reports Server (NTRS)
Patton, J. M., Jr.
1972-01-01
This paper presents pilot opinion supported by test data concerning flight control and display concepts and control system design requirements for VTOL aircraft in the instrument approach task. Material presented is drawn from research flights in the following aircraft: Dornier DO-31, Short SC-1, LTV XC-142A, and Boeing-Vertol CH-46. The control system concepts and mechanizations employed in the above aircraft are discussed, and the effect of control system augmentation is shown on performance. Operational procedures required in the instrument approach task are described, with comments on need for automation and combining of control functions.
NASA Technical Reports Server (NTRS)
Gibson, A. F.
1983-01-01
A system of computer programs has been developed to model general three-dimensional surfaces. Surfaces are modeled as sets of parametric bicubic patches. There are also capabilities to transform coordinate to compute mesh/surface intersection normals, and to format input data for a transonic potential flow analysis. A graphical display of surface models and intersection normals is available. There are additional capabilities to regulate point spacing on input curves and to compute surface intersection curves. Internal details of the implementation of this system are explained, and maintenance procedures are specified.
2007-12-01
37 3. Poka - yoke ............................................................................................37 4. Systems for...Standard operating procedures • Visual displays for workflow and communication • Total productive maintenance • Poka - yoke techniques to prevent...process step or eliminating non-value-added steps, and reducing the seven common wastes, will decrease the total time of a process. 3. Poka - yoke
Flying SATS Higher Volume Operations: Training, Lessons Learned, and Pilots' Experiences
NASA Technical Reports Server (NTRS)
Conway, Sheila; Williams, Dan; Adams, Catherine; Consiglio, Maria; Murdoch, Jennifer
2005-01-01
Developments in aviation, including new surveillance technologies and quicker, more economical small aircraft, have been identified as driving factors in a potential expansion of the use of non-towered, non-radar airports. The Small Aircraft Transportation System (SATS) project has developed the Higher Volume Operations (HVO) concept that enables pilots to safely arrive and depart these airports in instrument conditions at an increased rate as compared to today's procedures. This is achieved by transferring some traffic management tasks to centralized, ground-based automation, while assigning others to participating pilots aided by on-board tools. This paper describes strategies and lessons learned while training pilots to fly these innovative operations. Pilot approaches to using the experimental displays and dynamic altering systems during training are discussed. Potential operational benefits as well as pit-falls and frustrations expressed by subjects while learning to fly these new procedures are presented. Generally, pilots were comfortable with the procedures and the training process, and expressed interest in its near-term implementation.
An English language interface for constrained domains
NASA Technical Reports Server (NTRS)
Page, Brenda J.
1989-01-01
The Multi-Satellite Operations Control Center (MSOCC) Jargon Interpreter (MJI) demonstrates an English language interface for a constrained domain. A constrained domain is defined as one with a small and well delineated set of actions and objects. The set of actions chosen for the MJI is from the domain of MSOCC Applications Executive (MAE) Systems Test and Operations Language (STOL) directives and contains directives for signing a cathode ray tube (CRT) on or off, calling up or clearing a display page, starting or stopping a procedure, and controlling history recording. The set of objects chosen consists of CRTs, display pages, STOL procedures, and history files. Translation from English sentences to STOL directives is done in two phases. In the first phase, an augmented transition net (ATN) parser and dictionary are used for determining grammatically correct parsings of input sentences. In the second phase, grammatically typed sentences are submitted to a forward-chaining rule-based system for interpretation and translation into equivalent MAE STOL directives. Tests of the MJI show that it is able to translate individual clearly stated sentences into the subset of directives selected for the prototype. This approach to an English language interface may be used for similarly constrained situations by modifying the MJI's dictionary and rules to reflect the change of domain.
Simulation procedure for modeling transient water table and artesian stress and response
Reed, J.E.; Bedinger, M.S.; Terry, J.E.
1976-01-01
The series of computer programs described in this report were designed specifically to model the ground-water regime in sufficient detail to determine the effects of the imposition of various types of stress upon the system, and to display the results in a convenient manner during calibration and when presenting projected data. SUPERMOCK simulates the ground-water system and DATE and HYDROG aid in the display of computed data. During calibration, DATE is especially useful because it has the optional feature of comparing computed data with observed data. Although the programs can be run independently, experience dictates that for best results the three should be run as steps in the same job. English units of inches, feet, and days are used in each of the programs. The units for any parameters not given in the text are clearly specified in the instructions for input to the individual programs. (Woodard-USGS)
Co-located haptic and 3D graphic interface for medical simulations.
Berkelman, Peter; Miyasaka, Muneaki; Bozlee, Sebastian
2013-01-01
We describe a system which provides high-fidelity haptic feedback in the same physical location as a 3D graphical display, in order to enable realistic physical interaction with virtual anatomical tissue during modelled procedures such as needle driving, palpation, and other interventions performed using handheld instruments. The haptic feedback is produced by the interaction between an array of coils located behind a thin flat LCD screen, and permanent magnets embedded in the instrument held by the user. The coil and magnet configuration permits arbitrary forces and torques to be generated on the instrument in real time according to the dynamics of the simulated tissue by activating the coils in combination. A rigid-body motion tracker provides position and orientation feedback of the handheld instrument to the computer simulation, and the 3D display is produced using LCD shutter glasses and a head-tracking system for the user.
Augmented reality building operations tool
Brackney, Larry J.
2014-09-09
A method (700) for providing an augmented reality operations tool to a mobile client (642) positioned in a building (604). The method (700) includes, with a server (660), receiving (720) from the client (642) an augmented reality request for building system equipment (612) managed by an energy management system (EMS) (620). The method (700) includes transmitting (740) a data request for the equipment (612) to the EMS (620) and receiving (750) building management data (634) for the equipment (612). The method (700) includes generating (760) an overlay (656) with an object created based on the building management data (634), which may be sensor data, diagnostic procedures, or the like. The overlay (656) is configured for concurrent display on a display screen (652) of the client (642) with a real-time image of the building equipment (612). The method (700) includes transmitting (770) the overlay (656) to the client (642).
Space shuttle configuration accounting functional design specification
NASA Technical Reports Server (NTRS)
1974-01-01
An analysis is presented of the requirements for an on-line automated system which must be capable of tracking the status of requirements and engineering changes and of providing accurate and timely records. The functional design specification provides the definition, description, and character length of the required data elements and the interrelationship of data elements to adequately track, display, and report the status of active configuration changes. As changes to the space shuttle program levels II and III configuration are proposed, evaluated, and dispositioned, it is the function of the configuration management office to maintain records regarding changes to the baseline and to track and report the status of those changes. The configuration accounting system will consist of a combination of computers, computer terminals, software, and procedures, all of which are designed to store, retrieve, display, and process information required to track proposed and proved engineering changes to maintain baseline documentation of the space shuttle program levels II and III.
Use of an intuitive telemanipulator system for remote trauma surgery: an experimental study.
Bowersox, J C; Cordts, P R; LaPorta, A J
1998-06-01
Death from battlefield trauma occurs rapidly. Potentially salvageable casualties generally exsanguinate from truncal hemorrhage before operative intervention is possible. An intuitive telemanipulator system that would allow distant surgeons to remotely treat injured patients could improve the outcome from severe injuries. We evaluated a prototype, four-degree-of-freedom, telesurgery system that provides a surgeon with a stereoscopic video display of a remote operative field. Using dexterous robotic manipulators, surgical instruments at the remote site can be precisely controlled, enabling operative procedures to be performed remotely. Surgeons (n = 3) used the telesurgery system to perform organ excision, hemorrhage control, suturing, and knot tying on anesthetized swine. The ability to complete tasks, times required, technical quality, and subjective impressions were recorded. Surgeons using the telesurgery system were able to close gastrotomies remotely, although times required were 2.7 times as long as those performed by conventional techniques (451 +/- 83 versus 1,235 +/- 165 seconds, p < 0.002). Cholecystectomies, hemorrhage control from liver lacerations, and enterotomy closures were successfully completed in all attempts. Force feedback and stereoscopic video display were important for achieving intuitive performance with the telesurgery system, although tasks were completed adequately in the absence of these sensory cues. We demonstrated the feasibility of performing standard surgical procedures remotely, with the operating surgeon linked to the distant field only by electronic cabling. Complex manipulations were possible, although the times required were much longer. The capabilities of the system used would not support resuscitative surgery. Telesurgery is unlikely to play a role in early trauma management, but may be a unique research tool for acquiring basic knowledge of operative surgery.
Networks for image acquisition, processing and display
NASA Technical Reports Server (NTRS)
Ahumada, Albert J., Jr.
1990-01-01
The human visual system comprises layers of networks which sample, process, and code images. Understanding these networks is a valuable means of understanding human vision and of designing autonomous vision systems based on network processing. Ames Research Center has an ongoing program to develop computational models of such networks. The models predict human performance in detection of targets and in discrimination of displayed information. In addition, the models are artificial vision systems sharing properties with biological vision that has been tuned by evolution for high performance. Properties include variable density sampling, noise immunity, multi-resolution coding, and fault-tolerance. The research stresses analysis of noise in visual networks, including sampling, photon, and processing unit noises. Specific accomplishments include: models of sampling array growth with variable density and irregularity comparable to that of the retinal cone mosaic; noise models of networks with signal-dependent and independent noise; models of network connection development for preserving spatial registration and interpolation; multi-resolution encoding models based on hexagonal arrays (HOP transform); and mathematical procedures for simplifying analysis of large networks.
Baumann, Martin; Keinath, Andreas; Krems, Josef F; Bengler, Klaus
2004-05-01
Despite the usefulness of new on-board information systems one has to be concerned about the potential distraction effects that they impose on the driver. Therefore, methods and procedures are necessary to assess the visual demand that is connected to the usage of an on-board system. The occlusion-method is considered a strong candidate as a procedure for evaluating display designs with regard to their visual demand. This paper reports results from two experimental studies conducted to further evaluate this method. In the first study, performance in using an in-car navigation system was measured under three conditions: static (parking lot), occlusion (shutter glasses), and driving. The results show that the occlusion-procedure can be used to simulate visual requirements of real traffic conditions. In a second study the occlusion method was compared to a global evaluation criterion based on the total task time. It can be demonstrated that the occlusion method can identify tasks which meet this criterion, but are yet irresolvable under driving conditions. It is concluded that the occlusion technique seems to be a reliable and valid method for evaluating visual and dialogue aspects of in-car information systems.
Buttussi, Fabio; Chittaro, Luca
2018-02-01
The increasing availability of head-mounted displays (HMDs) for home use motivates the study of the possible effects that adopting this new hardware might have on users. Moreover, while the impact of display type has been studied for different kinds of tasks, it has been scarcely explored in procedural training. Our study considered three different types of displays used by participants for training in aviation safety procedures with a serious game. The three displays were respectively representative of: (i) desktop VR (a standard desktop monitor), (ii) many setups for immersive VR used in the literature (an HMD with narrow field of view and a 3-DOF tracker), and (iii) new setups for immersive home VR (an HMD with wide field of view and 6-DOF tracker). We assessed effects on knowledge gain, and different self-reported measures (self-efficacy, engagement, presence). Unlike previous studies of display type that measured effects only immediately after the VR experience, we considered also a longer time span (2 weeks). Results indicated that the display type played a significant role in engagement and presence. The training benefits (increased knowledge and self-efficacy) were instead obtained, and maintained at two weeks, regardless of the display used. The paper discusses the implications of these results.
Efficacy of a novel IGS system in atrial septal defect repair
NASA Astrophysics Data System (ADS)
Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.
2013-03-01
Congenital heart disease occurs in 107.6 out of 10,000 live births, with Atrial Septal Defects (ASD) accounting for 10% of these conditions. Historically, ASDs were treated with open heart surgery using cardiopulmonary bypass, allowing a patch to be sewn over the defect. In 1976, King et al. demonstrated use of a transcatheter occlusion procedure, thus reducing the invasiveness of ASD repair. Localization during these catheter based procedures traditionally has relied on bi-plane fluoroscopy; more recently trans-esophageal echocardiography (TEE) and intra-cardiac echocardiography (ICE) have been used to navigate these procedures. Although there is a high success rate using the transcatheter occlusion procedure, fluoroscopy poses radiation dose risk to both patient and clinician. The impact of this dose to the patients is important as many of those undergoing this procedure are children, who have an increased risk associated with radiation exposure. Their longer life expectancy than adults provides a larger window of opportunity for expressing the damaging effects of ionizing radiation. In addition, epidemiologic studies of exposed populations have demonstrated that children are considerably more sensitive to the carcinogenic effects radiation. Image-guided surgery (IGS) uses pre-operative and intra-operative images to guide surgery or an interventional procedure. Central to every IGS system is a software application capable of processing and displaying patient images, registration between multiple coordinate systems, and interfacing with a tool tracking system. We have developed a novel image-guided surgery framework called Kit for Navigation by Image Focused Exploration (KNIFE). In this work we assess the efficacy of this image-guided navigation system for ASD repair using a series of mock clinical experiments designed to simulate ASD repair device deployment.
Extending Comprehensive Maritime Awareness to Disconnected Vessels and Users
2007-09-01
system shall: 7. Provide flexible , scalable, and tailorable techniques, processes, and procedures that can be adapted rapidly and securely 8...PS (1 2- 21 ) SO W (2 2- 23 ) St ak eh ol de r C om m un ic at io ns (2 4) Provide secure connection of Node 5 to CMA Node 4 1,4,5 8 19 Provide...6 7 13,24 Provide flexible system - allow user display customization 6 7 13 Provide accurate data and info 2,3 16, 20, 24 Provide accurate local data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Nina; Zhou, Nan; Fridley, David
2012-03-01
This report presents a technical review of international minimum energy performance standards (MEPS), voluntary and mandatory energy efficiency labels and test procedures for five products being considered for new or revised MEPS in China: copy machines, external power supply, LED displays, residential gas cooktops and flat-screen televisions. For each product, an overview of the scope of existing international standards and labeling programs, energy values and energy performance metrics and description and detailed summary table of criteria and procedures in major test standards are presented.
Acevedo-Rocha, Carlos G; Agudo, Ruben; Reetz, Manfred T
2014-12-10
Directed evolution of stereoselective enzymes provides a means to generate useful biocatalysts for asymmetric transformations in organic chemistry and biotechnology. Almost all of the numerous examples reported in the literature utilize high-throughput screening systems based on suitable analytical techniques. Since the screening step is the bottleneck of the overall procedure, researchers have considered the use of genetic selection systems as an alternative to screening. In principle, selection would be the most elegant and efficient approach because it is based on growth advantage of host cells harboring stereoselective mutants, but devising such selection systems is very challenging. They must be designed so that the host organism profits from the presence of an enantioselective variant. Progress in this intriguing research area is summarized in this review, which also includes some examples of display systems designed for enantioselectivity as assayed by fluorescence-activated cell sorting (FACS). Although the combination of display systems and FACS is a powerful approach, we also envision innovative ideas combining metabolic engineering and genetic selection systems with protein directed evolution for the development of highly selective and efficient biocatalysts. Copyright © 2014 Elsevier B.V. All rights reserved.
Biased selection of propagation-related TUPs from phage display peptide libraries.
Zade, Hesam Motaleb; Keshavarz, Reihaneh; Shekarabi, Hosna Sadat Zahed; Bakhshinejad, Babak
2017-08-01
Phage display is rapidly advancing as a screening strategy in drug discovery and drug delivery. Phage-encoded combinatorial peptide libraries can be screened through the affinity selection procedure of biopanning to find pharmaceutically relevant cell-specific ligands. However, the unwanted enrichment of target-unrelated peptides (TUPs) with no true affinity for the target presents an important barrier to the successful screening of phage display libraries. Propagation-related TUPs (Pr-TUPs) are an emerging but less-studied category of phage display-derived false-positive hits that are displayed on the surface of clones with faster propagation rates. Despite long regarded as an unbiased selection system, accumulating evidence suggests that biopanning may create biological bias toward selection of phage clones with certain displayed peptides. This bias can be dependent on or independent of the displayed sequence and may act as a major driving force for the isolation of fast-growing clones. Sequence-dependent bias is reflected by censorship or over-representation of some amino acids in the displayed peptide and sequence-independent bias is derived from either point mutations or rare recombination events occurring in the phage genome. It is of utmost interest to clean biopanning data by identifying and removing Pr-TUPs. Experimental and bioinformatic approaches can be exploited for Pr-TUP discovery. With no doubt, obtaining deeper insight into how Pr-TUPs emerge during biopanning and how they could be detected provides a basis for using cell-targeting peptides isolated from phage display screening in the development of disease-specific diagnostic and therapeutic platforms.
3-D video techniques in endoscopic surgery.
Becker, H; Melzer, A; Schurr, M O; Buess, G
1993-02-01
Three-dimensional visualisation of the operative field is an important requisite for precise and fast handling of open surgical operations. Up to now it has only been possible to display a two-dimensional image on the monitor during endoscopic procedures. The increasing complexity of minimal invasive interventions requires endoscopic suturing and ligatures of larger vessels which are difficult to perform without the impression of space. Three-dimensional vision therefore may decrease the operative risk, accelerate interventions and widen the operative spectrum. In April 1992 a 3-D video system developed at the Nuclear Research Center Karlsruhe, Germany (IAI Institute) was applied in various animal experimental procedures and clinically in laparoscopic cholecystectomy. The system works with a single monitor and active high-speed shutter glasses. Our first trials with this new 3-D imaging system clearly showed a facilitation of complex surgical manoeuvres like mobilisation of organs, preparation in the deep space and suture techniques. The 3-D-system introduced in this article will enter the market in 1993 (Opticon Co., Karlsruhe, Germany.
Characterizing Feshbach resonances in ultracold scattering calculations
NASA Astrophysics Data System (ADS)
Frye, Matthew D.; Hutson, Jeremy M.
2017-10-01
We describe procedures for converging on and characterizing zero-energy Feshbach resonances that appear in scattering lengths for ultracold atomic and molecular collisions as a function of an external field. The elastic procedure is appropriate for purely elastic scattering, where the scattering length is real and displays a true pole. The regularized scattering length procedure is appropriate when there is weak background inelasticity, so that the scattering length is complex and displays an oscillation rather than a pole, but the resonant scattering length ares is close to real. The fully complex procedure is appropriate when there is substantial background inelasticity and the real and imaginary parts of ares are required. We demonstrate these procedures for scattering of ultracold 85Rb in various initial states. All of them can converge on and provide full characterization of resonances, from initial guesses many thousands of widths away, using scattering calculations at only about ten values of the external field.
[Autoshaping of a button-push response and eye movement in human subjects].
Kimura, H; Fukui, I; Inaki, K
1990-12-01
Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.
Medical color displays and their calibration
NASA Astrophysics Data System (ADS)
Fan, Jiahua; Roehrig, Hans; Dallas, W.; Krupinski, Elizabeth
2009-08-01
Color displays are increasingly used for medical imaging, replacing the traditional monochrome displays in radiology for multi-modality applications, 3D representation applications, etc. Color displays are also used increasingly because of wide spread application of Tele-Medicine, Tele-Dermatology and Digital Pathology. At this time, there is no concerted effort for calibration procedures for this diverse range of color displays in Telemedicine and in other areas of the medical field. Using a colorimeter to measure the display luminance and chrominance properties as well as some processing software we developed a first attempt to a color calibration protocol for the medical imaging field.
Bio-Photonic Detection of Various Cellular Cultures
NASA Astrophysics Data System (ADS)
Hann, Patrick; Garzon, Maria; Pfeiffer, Erik; Lofland, Samuel; Knoesel, Ernst
2008-03-01
Since it is non-invasive, there has been increased research in the field of bio-optics. Many biological systems display an unusual phenomenon, delayed luminescence, produced by what is known as bio-photons. We present an apparatus and procedure for the detection of these ultra-weak photonic emissions using a single photon detection device. The results of bread yeast, saccramyces, and algae will be presented and compared to other reports in the literature
Bio-Photons of Various Cellular Cultures and Tissues
NASA Astrophysics Data System (ADS)
Hann, Patrick; Knoesel, Ernst; Garzon, Maria; Lofland, Samuel; Pfieffer, Erik
2008-04-01
Since it is non-invasive, there has been increased research in the field of bio-optics. Many biological systems display an unusual phenomenon, delayed luminescence, produced by what is known as bio-photons. We present an apparatus and procedure for the detection of these ultra-weak photonic emissions using a single photon detection device. The results of bread yeast, saccramyces, and algae will be presented and compared to other reports in the literature.
Montgomery, L D; Montgomery, R W; Guisado, R
1995-05-01
This investigation demonstrates the feasibility of mental workload assessment by rheoencephalographic (REG) and multichannel electroencephalographic (EEG) monitoring. During the performance of this research, unique testing, analytical and display procedures were developed for REG and EEG monitoring that extend the current state of the art and provide valuable tools for the study of cerebral circulatory and neural activity during cognition. REG records are analyzed to provide indices of the right and left hemisphere hemodynamic changes that take place during each test sequence. The EEG data are modeled using regression techniques and mathematically transformed to provide energy-density distributions of the scalp electrostatic field. These procedures permit concurrent REG/EEG cognitive testing not possible with current techniques. The introduction of a system for recording and analysis of cognitive REG/EEG test sequences facilitates the study of learning and memory disorders, dementia and other encephalopathies.
NASA Technical Reports Server (NTRS)
Montgomery, L. D.; Montgomery, R. W.; Guisado, R.
1995-01-01
This investigation demonstrates the feasibility of mental workload assessment by rheoencephalographic (REG) and multichannel electroencephalographic (EEG) monitoring. During the performance of this research, unique testing, analytical and display procedures were developed for REG and EEG monitoring that extend the current state of the art and provide valuable tools for the study of cerebral circulatory and neural activity during cognition. REG records are analyzed to provide indices of the right and left hemisphere hemodynamic changes that take place during each test sequence. The EEG data are modeled using regression techniques and mathematically transformed to provide energy-density distributions of the scalp electrostatic field. These procedures permit concurrent REG/EEG cognitive testing not possible with current techniques. The introduction of a system for recording and analysis of cognitive REG/EEG test sequences facilitates the study of learning and memory disorders, dementia and other encephalopathies.
Pilot Performance on New ATM Operations: Maintaining In-Trail Separation and Arrival Sequencing
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Yankosky, L. J.; Johnson, Walter (Technical Monitor)
1999-01-01
Cockpit Display of Traffic Information (CDTI) may enable new Air Traffic Management (ATM) operations. However, CDTI is not the only source of traffic information in the cockpit; ATM procedures may provide information, implicitly and explicitly, about other aircraft. An experiment investigated pilot ability to perform two new ATM operations - maintaining in-trail separation from another aircraft and sequencing into an arrival stream. In the experiment, pilots were provided different amounts of information from displays and procedures. The results are described.
Barthel, Alexander; Johnson, Alex; Osgood, Greg; Kazanzides, Peter; Navab, Nassir; Fuerst, Bernhard
2018-01-01
Purpose Optical see-through head-mounted displays (OST-HMD) feature an unhindered and instantaneous view of the surgery site and can enable a mixed reality experience for surgeons during procedures. In this paper, we present a systematic approach to identify the criteria for evaluation of OST-HMD technologies for specific clinical scenarios, which benefit from using an object-anchored 2D-display visualizing medical information. Methods Criteria for evaluating the performance of OST-HMDs for visualization of medical information and its usage are identified and proposed. These include text readability, contrast perception, task load, frame rate, and system lag. We choose to compare three commercially available OST-HMDs, which are representatives of currently available head-mounted display technologies. A multi-user study and an offline experiment are conducted to evaluate their performance. Results Statistical analysis demonstrates that Microsoft HoloLens performs best among the three tested OST-HMDs, in terms of contrast perception, task load, and frame rate, while ODG R-7 offers similar text readability. The integration of indoor localization and fiducial tracking on the HoloLens provides significantly less system lag in a relatively motionless scenario. Conclusions With ever more OST-HMDs appearing on the market, the proposed criteria could be used in the evaluation of their suitability for mixed reality surgical intervention. Currently, Microsoft HoloLens may be more suitable than ODG R-7 and Epson Moverio BT-200 for clinical usability in terms of the evaluated criteria. To the best of our knowledge, this is the first paper that presents a methodology and conducts experiments to evaluate and compare OST-HMDs for their use as object-anchored 2D-display during interventions. PMID:28343301
Qian, Long; Barthel, Alexander; Johnson, Alex; Osgood, Greg; Kazanzides, Peter; Navab, Nassir; Fuerst, Bernhard
2017-06-01
Optical see-through head-mounted displays (OST-HMD) feature an unhindered and instantaneous view of the surgery site and can enable a mixed reality experience for surgeons during procedures. In this paper, we present a systematic approach to identify the criteria for evaluation of OST-HMD technologies for specific clinical scenarios, which benefit from using an object-anchored 2D-display visualizing medical information. Criteria for evaluating the performance of OST-HMDs for visualization of medical information and its usage are identified and proposed. These include text readability, contrast perception, task load, frame rate, and system lag. We choose to compare three commercially available OST-HMDs, which are representatives of currently available head-mounted display technologies. A multi-user study and an offline experiment are conducted to evaluate their performance. Statistical analysis demonstrates that Microsoft HoloLens performs best among the three tested OST-HMDs, in terms of contrast perception, task load, and frame rate, while ODG R-7 offers similar text readability. The integration of indoor localization and fiducial tracking on the HoloLens provides significantly less system lag in a relatively motionless scenario. With ever more OST-HMDs appearing on the market, the proposed criteria could be used in the evaluation of their suitability for mixed reality surgical intervention. Currently, Microsoft HoloLens may be more suitable than ODG R-7 and Epson Moverio BT-200 for clinical usability in terms of the evaluated criteria. To the best of our knowledge, this is the first paper that presents a methodology and conducts experiments to evaluate and compare OST-HMDs for their use as object-anchored 2D-display during interventions.
Hsieh, K S; Lin, C C; Liu, W S; Chen, F L
1996-01-01
Two-dimensional echocardiography had long been a standard diagnostic modality for congenital heart disease. Further attempts of three-dimensional reconstruction using two-dimensional echocardiographic images to visualize stereotypic structure of cardiac lesions have been successful only recently. So far only very few studies have been done to display three-dimensional anatomy of the heart through two-dimensional image acquisition because such complex procedures were involved. This study introduced a recently developed image acquisition and processing system for dynamic three-dimensional visualization of various congenital cardiac lesions. From December 1994 to April 1995, 35 cases were selected in the Echo Laboratory here from about 3000 Echo examinations completed. Each image was acquired on-line with specially designed high resolution image grazmber with EKG and respiratory gating technique. Off-line image processing using a window-architectured interactive software package includes construction of 2-D ehcocardiographic pixel to 3-D "voxel" with conversion of orthogonal to rotatory axial system, interpolation, extraction of region of interest, segmentation, shading and, finally, 3D rendering. Three-dimensional anatomy of various congenital cardiac defects was shown, including four cases with ventricular septal defects, two cases with atrial septal defects, and two cases with aortic stenosis. Dynamic reconstruction of a "beating heart" is recorded as vedio tape with video interface. The potential application of 3D display of the reconstruction from 2D echocardiographic images for the diagnosis of various congenital heart defects has been shown. The 3D display was able to improve the diagnostic ability of echocardiography, and clear-cut display of the various congenital cardiac defects and vavular stenosis could be demonstrated. Reinforcement of current techniques will expand future application of 3D display of conventional 2D images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sayler, E; Harrison, A; Eldredge-Hindy, H
Purpose: and Leipzig applicators (VLAs) are single-channel brachytherapy surface applicators used to treat skin lesions up to 2cm diameter. Source dwell times can be calculated and entered manually after clinical set-up or ultrasound. This procedure differs dramatically from CT-based planning; the novelty and unfamiliarity could lead to severe errors. To build layers of safety and ensure quality, a multidisciplinary team created a protocol and applied Failure Modes and Effects Analysis (FMEA) to the clinical procedure for HDR VLA skin treatments. Methods: team including physicists, physicians, nurses, therapists, residents, and administration developed a clinical procedure for VLA treatment. The procedure wasmore » evaluated using FMEA. Failure modes were identified and scored by severity, occurrence, and detection. The clinical procedure was revised to address high-scoring process nodes. Results: Several key components were added to the clinical procedure to minimize risk probability numbers (RPN): -Treatments are reviewed at weekly QA rounds, where physicians discuss diagnosis, prescription, applicator selection, and set-up. Peer review reduces the likelihood of an inappropriate treatment regime. -A template for HDR skin treatments was established in the clinical EMR system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planning physicist, and increases the detectability of an error during the physics second check. -A screen check was implemented during the second check to increase detectability of an error. -To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display. This facilitates data entry and verification. -VLAs are color-coded and labeled to match the EMR prescriptions, which simplifies in-room selection and verification. Conclusion: Multidisciplinary planning and FMEA increased delectability and reduced error probability during VLA HDR Brachytherapy. This clinical model may be useful to institutions implementing similar procedures.« less
Geophysical data analysis and visualization using the Grid Analysis and Display System
NASA Technical Reports Server (NTRS)
Doty, Brian E.; Kinter, James L., III
1995-01-01
Several problems posed by the rapidly growing volume of geophysical data are described, and a selected set of existing solutions to these problems is outlined. A recently developed desktop software tool called the Grid Analysis and Display System (GrADS) is presented. The GrADS' user interface is a natural extension of the standard procedures scientists apply to their geophysical data analysis problems. The basic GrADS operations have defaults that naturally map to data analysis actions, and there is a programmable interface for customizing data access and manipulation. The fundamental concept of the GrADS' dimension environment, which defines both the space in which the geophysical data reside and the 'slice' of data which is being analyzed at a given time, is expressed The GrADS' data storage and access model is described. An argument is made in favor of describable data formats rather than standard data formats. The manner in which GrADS users may perform operations on their data and display the results is also described. It is argued that two-dimensional graphics provides a powerful quantitative data analysis tool whose value is underestimated in the current development environment which emphasizes three dimensional structure modeling.
NASA Astrophysics Data System (ADS)
Rousson, Johanna; Haar, Jérémy; Santal, Sarah; Kumcu, Asli; Platiša, Ljiljana; Piepers, Bastian; Kimpe, Tom; Philips, Wilfried
2016-03-01
While three-dimensional (3-D) imaging systems are entering hospitals, no study to date has explored the luminance calibration needs of 3-D stereoscopic diagnostic displays and if they differ from two-dimensional (2-D) displays. Since medical display calibration incorporates the human contrast sensitivity function (CSF), we first assessed the 2-D CSF for benchmarking and then examined the impact of two image parameters on the 3-D stereoscopic CSF: (1) five depth plane (DP) positions (between DP: -171 and DP: 2853 mm), and (2) three 3-D inclinations (0 deg, 45 deg, and 60 deg around the horizontal axis of a DP). Stimuli were stereoscopic images of a vertically oriented 2-D Gabor patch at one of seven frequencies ranging from 0.4 to 10 cycles/deg. CSFs were measured for seven to nine human observers with a staircase procedure. The results indicate that the 2-D CSF model remains valid for a 3-D stereoscopic display regardless of the amount of disparity between the stereo images. We also found that the 3-D CSF at DP≠0 does not differ from the 3-D CSF at DP=0 for DPs and disparities which allow effortless binocular fusion. Therefore, the existing 2-D medical luminance calibration algorithm remains an appropriate tool for calibrating polarized stereoscopic medical displays.
Holographic Imaging In Dense Artificial Fog
NASA Technical Reports Server (NTRS)
Liu, Hua-Kuang; Marzwell, Neville
1996-01-01
Artificial fog serves as volume-projection medium for display of three-dimensional image. Projection technique enables display of images for variety of purposes, possibly including entertainment, indoor and outdoor advertising, medical diagnostics and image representations for surgical procedures, and education.
SU-F-P-44: A Direct Estimate of Peak Skin Dose for Interventional Fluoroscopy Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weir, V; Zhang, J
Purpose: There is an increasing demand for medical physicist to calculate peak skin dose (PSD) for interventional fluoroscopy procedures. The dose information (Dose-Area-Product and Air Kerma) displayed in the console cannot directly be used for this purpose. Our clinical experience shows that the use of the existing methods may overestimate or underestimate PSD. This study attempts to develop a direct estimate of PSD from the displayed dose metrics. Methods: An anthropomorphic torso phantom was used for dose measurements for a common fluoroscopic procedure. Entrance skin doses were measured with a Piranha solid state point detector placed on the table surfacemore » below the torso phantom. An initial “reference dose rate” (RE) measurement was conducted by comparing the displayed dose rate (mGy/min) to the dose rate measured. The distance from table top to focal spot was taken as the reference distance (RD at the RE. Table height was then adjusted. The displayed air kerma and DAP were recorded and sent to three physicists to estimate PSD. An inverse square correction was applied to correct displayed air kerma at various table heights. The PSD estimated by physicists and the PSD by the proposed method were then compared with the measurements. The estimated DAPs were compared to displayed DAP readings (mGycm2). Results: The difference between estimated PSD by the proposed method and direct measurements was less than 5%. For the same set of data, the estimated PSD by each of three physicists is different from measurements by ±52%. The DAP calculated by the proposed method and displayed DAP readings in the console is less than 20% at various table heights. Conclusion: PSD may be simply estimated from displayed air kerma or DAP if the distance between table top and tube focal spot or if x-ray beam area on table top is available.« less
Chromato-panning: an efficient new mode of identifying suitable ligands from phage display libraries
Noppe, Wim; Plieva, Fatima; Galaev, Igor Yu; Pottel, Hans; Deckmyn, Hans; Mattiasson, Bo
2009-01-01
Background Phage Display technology is a well established technique for high throughput screening of affinity ligands. Here we describe a new compact chromato-panning procedure for selection of suitable binders from a phage peptide display library. Results Both phages and E. coli cells pass non-hindered through the interconnected pores of macroporous gel, so called cryogel. After coupling a ligand to a monolithic cryogel column, the phage library was applied on the column and non-bound phages were washed out. The selection of strong phage-binders was achieved already after the first panning cycle due to the efficient separation of phage-binders from phage-non-binders in chromatographic mode rather than in batch mode as in traditional biopanning procedures. E. coli cells were applied on the column for infection with the specifically bound phages. Conclusion Chromato-panning allows combining several steps of the panning procedure resulting in 4–8 fold decrease of total time needed for phage selection. PMID:19292898
Meteorological data fields 'in perspective'
NASA Technical Reports Server (NTRS)
Hasler, A. F.; Pierce, H.; Morris, K. R.; Dodge, J.
1985-01-01
Perspective display techniques can be applied to meteorological data sets to aid in their interpretation. Examples of a perspective display procedure applied to satellite and aircraft visible and infrared image pairs and to stereo cloud-top height analyses are presented. The procedure uses a sophisticated shading algorithm that produces perspective images with greatly improved comprehensibility when compared with the wire-frame perspective displays that have been used in the past. By changing the 'eye-point' and 'view-point' inputs to the program in a systematic way, movie loops that give the impression of flying over or through the data field have been made. This paper gives examples that show how several kinds of meteorological data fields are more effectively illustrated using the perspective technique.
Bacteriophage T4 capsid packaging and unpackaging of DNA and proteins.
Mullaney, Julienne M; Black, Lindsay W
2014-01-01
Bacteriophage T4 has proven itself readily amenable to phage-based DNA and protein packaging, expression, and display systems due to its physical resiliency and genomic flexibility. As a large dsDNA phage with dispensable internal proteins and dispensable outer capsid proteins it can be adapted to package both DNA and proteins of interest within the capsid and to display peptides and proteins externally on the capsid. A single 170 kb linear DNA, or single or multiple copies of shorter linear DNAs, of any sequence can be packaged by the large terminase subunit in vitro into protein-containing proheads and give full or partially full capsids. The prohead receptacles for DNA packaging can also display peptides or full-length proteins from capsid display proteins HOC and SOC. Our laboratory has also developed a protein expression, packaging, and processing (PEPP) system which we have found to have advantages over mammalian and bacterial cell systems, including high yield, increased stability, and simplified downstream processing. Proteins that we have produced by the phage PEPP platform include human HIV-1 protease, micrococcal endonuclease from Staphylococcus aureus, restriction endonuclease EcoRI, luciferase, human granulocyte colony stimulating factor (GCSF), green fluorescent protein (GFP), and the 99 amino acid C-terminus of amyloid precursor protein (APP). Difficult to produce proteins that are toxic in mammalian protein expression systems are easily produced, packaged, and processed with the PEPP platform. APP is one example of such a highly refractory protein that has been produced successfully. The methods below describe the procedures for in vitro packaging of proheads with DNA and for producing recombinant T4 phage that carry a gene of interest in the phage genome and produce and internally package the corresponding protein of interest.
NASA Technical Reports Server (NTRS)
Stockwell, Alan E.; Cooper, Paul A.
1991-01-01
The Integrated Multidisciplinary Analysis Tool (IMAT) consists of a menu driven executive system coupled with a relational database which links commercial structures, structural dynamics and control codes. The IMAT graphics system, a key element of the software, provides a common interface for storing, retrieving, and displaying graphical information. The IMAT Graphics Manual shows users of commercial analysis codes (MATRIXx, MSC/NASTRAN and I-DEAS) how to use the IMAT graphics system to obtain high quality graphical output using familiar plotting procedures. The manual explains the key features of the IMAT graphics system, illustrates their use with simple step-by-step examples, and provides a reference for users who wish to take advantage of the flexibility of the software to customize their own applications.
Navigation and guidance requirements for commercial VTOL operations
NASA Technical Reports Server (NTRS)
Hoffman, W. C.; Hollister, W. M.; Howell, J. D.
1974-01-01
The NASA Langley Research Center (LaRC) has undertaken a research program to develop the navigation, guidance, control, and flight management technology base needed by Government and industry in establishing systems design concepts and operating procedures for VTOL short-haul transportation systems in the 1980s time period. The VALT (VTOL Automatic Landing Technology) Program encompasses the investigation of operating systems and piloting techniques associated with VTOL operations under all-weather conditions from downtown vertiports; the definition of terminal air traffic and airspace requirements; and the development of avionics including navigation, guidance, controls, and displays for automated takeoff, cruise, and landing operations. The program includes requirements analyses, design studies, systems development, ground simulation, and flight validation efforts.
Detection of endoscopic looping during colonoscopy procedure by using embedded bending sensors
Bruce, Michael; Choi, JungHun
2018-01-01
Background Looping of the colonoscope shaft during procedure is one of the most common obstacles encountered by colonoscopists. It occurs in 91% of cases with the N-sigmoid loop being the most common, occurring in 79% of cases. Purpose Herein, a novel system is developed that will give a complete three-dimensional (3D) vector image of the shaft as it passes through the colon, to aid the colonoscopist in detecting loops before they form. Patients and methods A series of connected links spans the middle 50% of the shaft, where loops are likely to form. Two potentiometers are attached at each joint to measure angular deflection in two directions to allow for 3D positioning. This 3D positioning is converted into a 3D vector image using computer software. MATLAB software has been used to display the image on a computer monitor. For the different configuration of the colon model, the system determined the looping status. Results Different configurations (N loop, reverse gamma loop, and reverse splenic flexure) of the loops were well defined using 3D vector image. Conclusion The novel sensory system can accurately define the various configuration of the colon during the colonoscopy procedure. PMID:29849469
Tsuchiya, Yoshiki; Tanaka, Kinji; Cook, Elton S.; Nutini, Leo G.
1970-01-01
By a short-term combined prophylactic-therapeutic procedure, the following compounds were found to be active against staphylococcal infections in Swiss mice: γ-aminobutyric acid, γ-amino-β-hydroxybutyric acid (GABOB), δ-amino-valeric acid (DAVA), ε-aminocaproic acid (EACA), trans-4-aminomethylcyclohexanecarboxylic acid (trans-AMCHA), taurine, and cysteic acid. Many of these compounds had displayed limited or no activity by a previously used prophylactic procedure. Although DAVA and GABOB were the most potent of the straight-chain ω-amino acids, trans-AMCHA displayed the greatest antistaphylococcic activity of the ω-amino acids thus far investigated. Homocarnosine (γ-aminobutyrl histidine, which also was active by the prophylactic procedure) equalled trans-AMCHA in activity. Taurine was similar in potency to DAVA, and the activity of cysteic acid approximated that of EACA. PMID:5422309
77 FR 15293 - Airworthiness Directives; Dassault Aviation Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-15
...-190-20), land at nearest suitable airport Upon display of ELEC:LH ESS PWR LO or ELEC:LH ESS NO PWR (Abnormal procedure 3-190-40), land at nearest suitable airport Upon display of ELEC:RH ESS PWR LO and ELEC...
Achieving consistent color and grayscale presentation on medial color displays
NASA Astrophysics Data System (ADS)
Fan, Jiahua; Roehrig, Hans; Dallas, William; Krupinski, Elizabeth A.
2008-03-01
Color displays are increasingly used for medical imaging, replacing the traditional monochrome displays in radiology for multi-modality applications, 3D representation applications, etc. Color displays are also used increasingly because of wide spread application of Tele-Medicine, Tele-Dermatology and Digital Pathology. At this time, there is no concerted effort for calibration procedures for this diverse range of color displays in Telemedicine and in other areas of the medical field. Using a colorimeter to measure the display luminance and chrominance properties as well as some processing software we developed a first attempt to a color calibration protocol for the medical imaging field.
Ruggedized Video Display System.
1984-01-01
111241-I Page -2- TEST PROCEDURE: In preparing the fungi cultures, the following fungi were used: ATCC No. QMC No. Aspergillus Niger 9642 386... Aspergillus Flavus 9643 380 Aspergillus Versicolor 11730 432 Penicillum Funiculosum 11797 474 Cheatomium Globosun 6205 459 Subculture of the above fungi were...z- A ll " , epurt umber I Page -, - T tU!OCI DURF prepa ri ng the fungi cultures the fo I ow n g fungi were used: ATCC No: OMC No. Iper-jllus niger
Advanced Spacesuit Informatics Software Design for Power, Avionics and Software Version 2.0
NASA Technical Reports Server (NTRS)
Wright, Theodore W.
2016-01-01
A description of the software design for the 2016 edition of the Informatics computer assembly of the NASAs Advanced Extravehicular Mobility Unit (AEMU), also called the Advanced Spacesuit. The Informatics system is an optional part of the spacesuit assembly. It adds a graphical interface for displaying suit status, timelines, procedures, and warning information. It also provides an interface to the suit mounted camera for recording still images, video, and audio field notes.
Makeyev, E V; Kolb, V A; Spirin, A S
1999-02-12
A novel cloning-independent strategy has been developed to generate a combinatorial library of PCR fragments encoding a murine single-chain antibody repertoire and express it directly in a cell-free system. The new approach provides an effective alternative to the techniques involving in vivo procedures of preparation and handling large libraries of antibodies. The possible use of the described strategy in the ribosome display is discussed.
NASA Technical Reports Server (NTRS)
Klumpar, D. M. (Principal Investigator)
1982-01-01
Progress made in reducing MAGSAT data and displaying magnetic field perturbations caused primarily by external currents is reported. A periodic and repeatable perturbation pattern is described that arises from external current effects but appears as unique signatures associated with upper middle latitudes on the Earth's surface. Initial testing of the modeling procedure that was developed to compute the magnetic fields at satellite orbit due to current distributions in the ionosphere and magnetosphere is also discussed. The modeling technique utilizes a linear current element representation of the large scale space current system.
STS-40 crewmembers use inflight blood collection system (IBCS) kit on middeck
NASA Technical Reports Server (NTRS)
1991-01-01
STS-40 crewmembers follow procedures for Experiment No. 261, The Influence of Space Flight on Erythrokinetics in Man, while on the middeck of Columbia, Orbiter Vehicle (OV) 102. Payload Specialist F. Drew Gaffney (center) draws blood from Payload Specialist Millie Hughes-Fulford (left) as Mission Specialist (MS) James P. Bagian looks on. The crewmembers are using the inflight blood collection system (IBCS) kit in front of the forward lockers and the orbiter refrigerator freezer (ORF). Displayed on the forward lockers are decals representing the Air Force, the Air Force Reserves (AFRES), University of Tennessee, Colorado State, and Stanford University.
NASA Astrophysics Data System (ADS)
Li, Jiawen; Ma, Teng; Jing, Joseph; Zhang, Jun; Patel, Pranav M.; Shung, K. Kirk; Zhou, Qifa; Chen, Zhongping
2014-03-01
We have developed a novel integrated optical coherence tomography (OCT)-intravascular ultrasound (IVUS) probe, with a 1.5 mm-long rigid-part and 0.9 mm outer diameter, for real-time intracoronary imaging of atherosclerotic plaques and guiding interventional procedures. By placing the OCT ball lens and IVUS 45MHz single element transducer back-to-back at the same axial position, this probe can provide automatically co-registered, co-axial OCT-IVUS imaging. To demonstrate its capability, 3D OCT-IVUS imaging of a pig's coronary artery in real-time displayed in polar coordinates, as well as images of two major types of advanced plaques in human cadaver coronary segments, was obtained using this probe and our upgraded system. Histology validation is also presented.
How a surgeon becomes superman by visualization of intelligently fused multi-modalities
NASA Astrophysics Data System (ADS)
Erat, Okan; Pauly, Olivier; Weidert, Simon; Thaller, Peter; Euler, Ekkehard; Mutschler, Wolf; Navab, Nassir; Fallavollita, Pascal
2013-03-01
Motivation: The existing visualization of the Camera augmented mobile C-arm (CamC) system does not have enough cues for depth information and presents the anatomical information in a confusing way to surgeons. Methods: We propose a method that segments anatomical information from X-ray and then augment it on the video images. To provide depth cues, pixels belonging to video images are classified as skin and object classes. The augmentation of anatomical information from X-ray is performed only when pixels have a larger probability of belonging to skin class. Results: We tested our algorithm by displaying the new visualization to 2 expert surgeons and 1 medical student during three surgical workflow sequences of the interlocking of intramedullary nail procedure, namely: skin incision, center punching, and drilling. Via a survey questionnaire, they were asked to assess the new visualization when compared to the current alphablending overlay image displayed by CamC. The participants all agreed (100%) that occlusion and instrument tip position detection were immediately improved with our technique. When asked if our visualization has potential to replace the existing alpha-blending overlay during interlocking procedures, all participants did not hesitate to suggest an immediate integration of the visualization for the correct navigation and guidance of the procedure. Conclusion: Current alpha blending visualizations lack proper depth cues and can be a source of confusion for the surgeons when performing surgery. Our visualization concept shows great potential in alleviating occlusion and facilitating clinician understanding during specific workflow steps of the intramedullary nailing procedure.
Mutual information, neural networks and the renormalization group
NASA Astrophysics Data System (ADS)
Koch-Janusz, Maciej; Ringel, Zohar
2018-06-01
Physical systems differing in their microscopic details often display strikingly similar behaviour when probed at macroscopic scales. Those universal properties, largely determining their physical characteristics, are revealed by the powerful renormalization group (RG) procedure, which systematically retains `slow' degrees of freedom and integrates out the rest. However, the important degrees of freedom may be difficult to identify. Here we demonstrate a machine-learning algorithm capable of identifying the relevant degrees of freedom and executing RG steps iteratively without any prior knowledge about the system. We introduce an artificial neural network based on a model-independent, information-theoretic characterization of a real-space RG procedure, which performs this task. We apply the algorithm to classical statistical physics problems in one and two dimensions. We demonstrate RG flow and extract the Ising critical exponent. Our results demonstrate that machine-learning techniques can extract abstract physical concepts and consequently become an integral part of theory- and model-building.
An immersive surgery training system with live streaming capability.
Yang, Yang; Guo, Xinqing; Yu, Zhan; Steiner, Karl V; Barner, Kenneth E; Bauer, Thomas L; Yu, Jingyi
2014-01-01
Providing real-time, interactive immersive surgical training has been a key research area in telemedicine. Earlier approaches have mainly adopted videotaped training that can only show imagery from a fixed view point. Recent advances on commodity 3D imaging have enabled a new paradigm for immersive surgical training by acquiring nearly complete 3D reconstructions of actual surgical procedures. However, unlike 2D videotaping that can easily stream data in real-time, by far 3D imaging based solutions require pre-capturing and processing the data; surgical trainings using the data have to be conducted offline after the acquisition. In this paper, we present a new real-time immersive 3D surgical training system. Our solution builds upon the recent multi-Kinect based surgical training system [1] that can acquire and display high delity 3D surgical procedures using only a small number of Microsoft Kinect sensors. We build on top of the system a client-server model for real-time streaming. On the server front, we efficiently fuse multiple Kinect data acquired from different viewpoints and compress and then stream the data to the client. On the client front, we build an interactive space-time navigator to allow remote users (e.g., trainees) to witness the surgical procedure in real-time as if they were present in the room.
Hamamichi, S; Nishigori, H
2001-02-28
Early detection and removal of harmful factors are essential to the proper physical and psychological development of the fetus, presumably showing the effects during the prenatal period and after birth. As one procedure to aid in understanding such factors, we have established a shell-less culture system for video monitoring to observe change in behavior of 7-day-old chick embryos. Nicotine and aqueous cigarette smoke extract (ACSE) were selected for the present experiments, and the results showed a complete stoppage of swing-like movements by administrations of 10 microg nicotine and 1xACSE, possibly displaying paralytic symptoms. Quantitative analysis of nicotine in 1xACSE indicated that more than 10 microg of nicotine were contained in 100 microl of the extract. The present system, although in initial stage of development, may be a useful preliminary screening procedure for perhaps supervision and warning about the environment surrounding pregnant women.
Terminal Area Procedures for Paired Runways
NASA Technical Reports Server (NTRS)
Lozito, Sandy
2011-01-01
Parallel Runway operations have been found to increase capacity within the National Airspace (NAS) however, poor visibility conditions reduce this capacity [1]. Much research has been conducted to examine the concepts and procedures related to parallel runways however, there has been no investigation of the procedures associated with the strategic and tactical pairing of aircraft for these operations. This study developed and examined the pilot and controller procedures and information requirements for creating aircraft pairs for parallel runway operations. The goal was to achieve aircraft pairing with a temporal separation of 15s(+/- 10s error) at a coupling point that is about 12 nmi from the runway threshold. Two variables were explored for the pilot participants: Two levels of flight deck automation (current-day flight deck automation, and a prototype future automation) as well as two flight deck displays that assisted in pilot conformance monitoring. The controllers were also provided with automation to help create and maintain aircraft pairs. Data showed that the operations in this study were found to be acceptable and safe. Workload when using the pairing procedures and tools was generally low for both controllers and pilots, and situation awareness (SA) was typically moderate to high. There were some differences based upon the display and automation conditions for the pilots. Future research should consider the refinement of the concepts and tools for pilot and controller displays and automation for parallel runway concepts.
Evanoff, M G; Roehrig, H; Giffords, R S; Capp, M P; Rovinelli, R J; Hartmann, W H; Merritt, C
2001-06-01
This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.
The universal serial bus endoscope: design and initial clinical experience.
Hernandez-Zendejas, Gregorio; Dobke, Marek K; Guerrerosantos, Jose
2004-01-01
Endoscopic forehead lift is a well-established procedure in aesthetic plastic surgery. Many agree that currently available video-endoscopic equipment is bulky, multipieced and sometimes cumbersome in the operating theater. A novel system, the Universal Serial Bus Endoscope (USBE) was designed to simplify and reduce the number of necessary equipment pieces in the endoscopic setup. The USBE is attached by a single cable to a Universal Serial Bus (USB) port of a laptop computer. A built-in miniaturized cold light source provides illumination. A built-in digital camera chip enables procedure recording. The real-time images and movies obtained with USBE are displayed on the computer's screen and recorded on the laptop's hard disk drive. In this study, 25 patients underwent endoscopic browlift using the USBE system to test its clinical usefulness, all with good results and without complications or need for revision. The USBE was found to be reliable and easier to use than current video-endoscope equipment. The operative time needed to complete the procedure by the authors was reduced approximately 50%. The design and main technical characteristics of the USBE are presented.
Web-based video monitoring of CT and MRI procedures
NASA Astrophysics Data System (ADS)
Ratib, Osman M.; Dahlbom, Magdalena; Kho, Hwa T.; Valentino, Daniel J.; McCoy, J. Michael
2000-05-01
A web-based video transmission of images from CT and MRI consoles was implemented in an Intranet environment for real- time monitoring of ongoing procedures. Images captured from the consoles are compressed to video resolution and broadcasted through a web server. When called upon, the attending radiologists can view these live images on any computer within the secured Intranet network. With adequate compression, these images can be displayed simultaneously in different locations at a rate of 2 to 5 images/sec through standard LAN. The quality of the images being insufficient for diagnostic purposes, our users survey showed that they were suitable for supervising a procedure, positioning the imaging slices and for routine quality checking before completion of a study. The system was implemented at UCLA to monitor 9 CTs and 6 MRIs distributed in 4 buildings. This system significantly improved the radiologists productivity by saving precious time spent in trips between reading rooms and examination rooms. It also improved patient throughput by reducing the waiting time for the radiologists to come to check a study before moving the patient from the scanner.
NASA Technical Reports Server (NTRS)
Holden, Kritina; Sandor, A.; Thompson, S. G.; McCann, R. S.; Kaiser, M. K.; Begault, D. R.; Adelstein, B. D.; Beutter, B. R.; Stone, L. S.
2008-01-01
The goal of the Information Presentation Directed Research Project (DRP) is to address design questions related to the presentation of information to the crew on flight vehicles, surface landers and habitats, and during extra-vehicular activities (EVA). Designers of displays and controls for exploration missions must be prepared to select the text formats, label styles, alarms, electronic procedure designs, and cursor control devices that provide for optimal crew performance on exploration tasks. The major areas of work, or subtasks, within the Information Presentation DRP are: 1) Controls, 2) Displays, 3) Procedures, and 4) EVA Operations.
Comparative gene expression in sexual and apomictic ovaries of Pennisetum ciliare (L.) Link.
Vielle-Calzada, J P; Nuccio, M L; Budiman, M A; Thomas, T L; Burson, B L; Hussey, M A; Wing, R A
1996-12-01
Limited emphasis has been given to the molecular study of apomixis, an asexual method of reproduction where seeds are produced without fertilization. Most buffelgrass (Pennisetum ciliare (L.) Link syn = Cenchrus ciliaris L.) genotypes reproduce by obligate apomixis (apospory); however, rare sexual plants have been recovered. A modified differential display procedure was used to compare gene expression in unpollinated ovaries containing ovules with either sexual or apomictic female gametophytes. The modification incorporated end-labeled poly(A)+ anchored primers as the only isotopic source, and was a reliable and consistent approach for detecting differentially displayed transcripts. Using 20 different decamers and two anchor primers, 2268 cDNA fragments between 200 and 600 bp were displayed. From these, eight reproducible differentially displayed cDNAs were identified and cloned. Based on northern analysis, one cDNA was detected in only the sexual ovaries, two cDNAs in only apomictic ovaries and one cDNA was present in both types of ovaries. Three fragments could not be detected and one fragment was detected in ovaries, stems, and leaves. Comparison of gene expression during sexual and apomictic development in buffelgrass represents a new model system and a strategy for investigating female reproductive development in the angiosperms.
Promoting convergence: The Phi spiral in abduction of mouse corneal behaviors
Rhee, Jerry; Nejad, Talisa Mohammad; Comets, Olivier; Flannery, Sean; Gulsoy, Eine Begum; Iannaccone, Philip; Foster, Craig
2015-01-01
Why do mouse corneal epithelial cells display spiraling patterns? We want to provide an explanation for this curious phenomenon by applying an idealized problem solving process. Specifically, we applied complementary line-fitting methods to measure transgenic epithelial reporter expression arrangements displayed on three mature, live enucleated globes to clarify the problem. Two prominent logarithmic curves were discovered, one of which displayed the ϕ ratio, an indicator of an optimal configuration in phyllotactic systems. We then utilized two different computational approaches to expose our current understanding of the behavior. In one procedure, which involved an isotropic mechanics-based finite element method, we successfully produced logarithmic spiral curves of maximum shear strain based pathlines but computed dimensions displayed pitch angles of 35° (ϕ spiral is ∼17°), which was altered when we fitted the model with published measurements of coarse collagen orientations. We then used model-based reasoning in context of Peircean abduction to select a working hypothesis. Our work serves as a concise example of applying a scientific habit of mind and illustrates nuances of executing a common method to doing integrative science. © 2014 Wiley Periodicals, Inc. Complexity 20: 22–38, 2015 PMID:25755620
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L
2015-02-01
Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based proceduremore » system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the underlying data structure for such CBPS. The objective of the research effort is to develop guidance on how to design both the user interface and the underlying schema. This paper will describe the result and insights gained from the research activities conducted to date.« less
The energy landscape of a selective tumor-homing pentapeptide
Zanuy, David; Flores-Ortega, Alejandra; Casanovas, Jordi; Curco, David; Nussinov, Ruth; Aleman, Carlos
2009-01-01
Recently, a potentially powerful strategy based on the of phage-display libraries has been presented to target tumors via homing peptides attached to nanoparticles. The Cys-Arg-Glu-Lys-Ala (CREKA) peptide sequence has been identified as a tumor-homing peptide that binds to clotted plasmas proteins present in tumor vessels and interstitium. The aim of this work consists of mapping the conformational profile of CREKA to identify the bioactive conformation. For this purpose, a conformational search procedure based on modified Simulated Annealing combined with Molecular Dynamics was applied to three systems that mimic the experimentally used conditions: (i) the free peptide; (ii) the peptide attached to a nanoparticle; and (iii) the peptide inserted in a phage display protein. In addition, the free peptide was simulated in an ionized aqueous solution environment, which mimics the ionic strength of the physiological medium. Accessible minima of all simulated systems reveal a multiple interaction pattern involving the ionized side chains of Arg, Glu and Lys, which induces a β-turn motif in the backbone observed in all simulated CREKA systems. PMID:18588341
CISN ShakeAlert: Using early warnings for earthquakes in California
NASA Astrophysics Data System (ADS)
Vinci, M.; Hellweg, M.; Jones, L. M.; Khainovski, O.; Schwartz, K.; Lehrer, D.; Allen, R. M.; Neuhauser, D. S.
2009-12-01
Educated users who have developed response plans and procedures are just as important for an earthquake early warning (EEW) system as are the algorithms and computers that process the data and produce the warnings. In Japan, for example, the implementation of the EEW system which now provides advanced alerts of ground shaking included intense outreach efforts to both institutional and individual recipients. Alerts are now used in automatic control systems that stop trains, place sensitive equipment in safe mode and isolate hazards while the public takes cover. In California, the California Integrated Seismic Network (CISN) is now developing and implementing components of a prototype system for EEW, ShakeAlert. As this processing system is developed, we invite a suite of perspective users from critical industries and institutions throughout California to partner with us in developing useful ShakeAlert products and procedures. At the same time, we will support their efforts to determine and implement appropriate responses to an early warning of earthquake shaking. As a first step, in a collaboration with BART, we have developed a basic system allowing BART’s operation center to receive realtime ground shaking information from more than 150 seismic stations operating in the San Francisco Bay Area. BART engineers are implementing a display system for this information. Later phases will include the development of improved response procedures utilizing this information. We plan to continue this collaboration to include more sophisticated information from the prototype CISN ShakeAlert system.
Dexter, Franklin; Epstein, Richard H; Lee, John D; Ledolter, Johannes
2009-03-01
Operating room (OR) whiteboards (status displays) communicate times remaining for ongoing cases to perioperative stakeholders (e.g., postanesthesia care unit, anesthesiologists, holding area, and control desks). Usually, scheduled end times are shown for each OR. However, these displays are inaccurate for predicting the time that remains in a case. Once a case scheduled for 2 h has been on-going for 1.5 h, the median time remaining is not 0.5 h but longer, and the amount longer differs among procedures. We derived the conditional Bayesian lower prediction bound of a case's duration, conditional on the minutes of elapsed OR time. Our derivations make use of the posterior predictive distribution of OR times following an exponential of a scaled Student t distribution that depends on the scheduled OR time and several parameters calculated from historical case duration data. The statistical method was implemented using Structured Query Language (SQL) running on the anesthesia information management system (AIMS) database server. In addition, AIMS workstations were sent instant messages displaying a pop-up dialog box asking for anesthesia providers' estimates for remaining times. The dialogs caused negotiated interruptions (i.e., the anesthesia provider could reply immediately, keep the dialog displayed, or defer response). There were no announcements, education, or efforts to promote buy-in. After a case had been in the OR longer than scheduled, the median remaining OR time for the case changes little over time (e.g., 35 min left at 2:30 pm and also at 3:00 pm while the case was still on-going). However, the remaining time differs substantially among surgeons and scheduled procedure(s) (16 min longer [10th percentile], 35 min [50th], and 86 min [90th]). We therefore implemented an automatic method to estimate the times remaining in cases. The system was operational for >119 of each day's 120 5-min intervals. When instant message dialogs appearing on AIMS workstations were used to elicit estimates of times remaining from anesthesia providers, acknowledgment was on average within 1.2 min (95% confidence interval [CI] 1.1-1.3 min). The 90th percentile of latencies was 6.5 min (CI: 4.4-7.0 min). For cases taking nearly as long as or longer than scheduled, each 1 min progression of OR time reduces the median time remaining in a case by <1 min. We implemented automated calculation of times remaining for every case at a 29 OR hospital.
Skagerlund, Kenny; Träff, Ulf
2016-01-01
This study investigated if developmental dyscalculia (DD) in children with different profiles of mathematical deficits has the same or different cognitive origins. The defective approximate number system hypothesis and the access deficit hypothesis were tested using two different groups of children with DD (11-13 years old): a group with arithmetic fact dyscalculia (AFD) and a group with general dyscalculia (GD). Several different aspects of number magnitude processing were assessed in these two groups and compared with age-matched typically achieving children. The GD group displayed weaknesses with both symbolic and nonsymbolic number processing, whereas the AFD group displayed problems only with symbolic number processing. These findings provide evidence that the origins of DD in children with different profiles of mathematical problems diverge. Children with GD have impairment in the innate approximate number system, whereas children with AFD suffer from an access deficit. These findings have implications for researchers' selection procedures when studying dyscalculia, and also for practitioners in the educational setting. © Hammill Institute on Disabilities 2014.
Pre and post processing using the IBM 3277 display station graphics attachment (RPQ7H0284)
NASA Technical Reports Server (NTRS)
Burroughs, S. H.; Lawlor, M. B.; Miller, I. M.
1978-01-01
A graphical interactive procedure operating under TSO and utilizing two CRT display terminals is shown to be an effective means of accomplishing mesh generation, establishing boundary conditions, and reviewing graphic output for finite element analysis activity.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Exclusions. 15.103 Section 15.103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PROCEDURAL RULES... chart or map; (3) Was not accurately displayed on a visual display in the cockpit, or (4) Was obviously...
[Review of visual display system in flight simulator].
Xie, Guang-hui; Wei, Shao-ning
2003-06-01
Visual display system is the key part and plays a very important role in flight simulators and flight training devices. The developing history of visual display system is recalled and the principle and characters of some visual display systems including collimated display systems and back-projected collimated display systems are described. The future directions of visual display systems are analyzed.
Candidate CDTI procedures study
NASA Technical Reports Server (NTRS)
Ace, R. E.
1981-01-01
A concept with potential for increasing airspace capacity by involving the pilot in the separation control loop is discussed. Some candidate options are presented. Both enroute and terminal area procedures are considered and, in many cases, a technologically advanced Air Traffic Control structure is assumed. Minimum display characteristics recommended for each of the described procedures are presented. Recommended sequencing of the operational testing of each of the candidate procedures is presented.
Potential impacts of advanced technologies on the ATC capacity of high-density terminal areas
NASA Technical Reports Server (NTRS)
Simpson, R. W.; Odoni, A. R.; Salas-Roche, F.
1986-01-01
Advanced technologies for airborne systems (automatic flight control, flight displays, navigation) and for ground ATC systems (digital communications, improved surveillance and tracking, automated decision-making) create the possibility of advanced ATC operations and procedures which can bring increased capacity for runway systems. A systematic analysis is carried out to identify certain such advanced ATC operations, and then to evaluate the potential benefits occurring over time at typical US high-density airports (Denver and Boston). The study is divided into three parts: (1) A Critical Examination of Factors Which Determine Operational Capacity of Runway Systems at Major Airports, is an intensive review of current US separation criteria and terminal area ATC operations. It identifies 11 new methods to increase the capacity of landings and takeoffs for runway systems; (2) Development of Risk Based Separation Criteria is the development of a rational structure for establishing reduced ATC separation criteria which meet a consistent Target Level of Safety using advanced technology and operational procedures; and (3) Estimation of Capacity Benefits from Advanced Terminal Area Operations - Denver and Boston, provides an estimate of the overall annual improvement in runway capacity which might be expected at Denver and Boston from using some of the advanced ATC procedures developed in Part 1. Whereas Boston achieved a substantial 37% increase, Denver only achieved a 4.7% increase in its overall annual capacity.
2017-04-30
Defense, “Chemical Agent Resistant Coating (CARC) System Application Procedures and Quality Control Inspection”, Washington, DC, June 2003. 4. Non ...WP-200906) Non -Chromate, ZVOC Coatings for Steel Substrates on Army and Navy Aircraft and Ground Vehicles Non -Chromate Sealers for Zinc...comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE
2013-09-01
through direct sampling of form and content of critical display data. Evidence of construct validity is provided by correlation with the Colour ...measured by the Colour Assessment and Diagnosis (CAD; ARTS Background Colors STARS Background Colors ERAM Background Colors Figure 3...Gelade, G. (1980). A feature-integration theory of attention. Cognitive Psychology , 12, 97–136. Xing, J. & Schroeder, D.J. (2006). Reexamination of
Loy Rodas, Nicolas; Barrera, Fernando; Padoy, Nicolas
2017-02-01
We present an approach to provide awareness to the harmful ionizing radiation generated during X-ray-guided minimally invasive procedures. A hand-held screen is used to display directly in the user's view information related to radiation safety in a mobile augmented reality (AR) manner. Instead of using markers, we propose a method to track the observer's viewpoint, which relies on the use of multiple RGB-D sensors and combines equipment detection for tracking initialization with a KinectFusion-like approach for frame-to-frame tracking. Two of the sensors are ceiling-mounted and a third one is attached to the hand-held screen. The ceiling cameras keep an updated model of the room's layout, which is used to exploit context information and improve the relocalization procedure. The system is evaluated on a multicamera dataset generated inside an operating room (OR) and containing ground-truth poses of the AR display. This dataset includes a wide variety of sequences with different scene configurations, occlusions, motion in the scene, and abrupt viewpoint changes. Qualitative results illustrating the different AR visualization modes for radiation awareness provided by the system are also presented. Our approach allows the user to benefit from a large AR visualization area and permits to recover from tracking failure caused by vast motion or changes in the scene just by looking at a piece of equipment. The system enables the user to see the 3-D propagation of radiation, the medical staff's exposure, and/or the doses deposited on the patient's surface as seen through his own eyes.
General Aviation Flight Test of Advanced Operations Enabled by Synthetic Vision
NASA Technical Reports Server (NTRS)
Glaab, Louis J.; Hughhes, Monica F.; Parrish, Russell V.; Takallu, Mohammad A.
2014-01-01
A flight test was performed to compare the use of three advanced primary flight and navigation display concepts to a baseline, round-dial concept to assess the potential for advanced operations. The displays were evaluated during visual and instrument approach procedures including an advanced instrument approach resembling a visual airport traffic pattern. Nineteen pilots from three pilot groups, reflecting the diverse piloting skills of the General Aviation pilot population, served as evaluation subjects. The experiment had two thrusts: 1) an examination of the capabilities of low-time (i.e., <400 hours), non-instrument-rated pilots to perform nominal instrument approaches, and 2) an exploration of potential advanced Visual Meteorological Conditions (VMC)-like approaches in Instrument Meteorological Conditions (IMC). Within this context, advanced display concepts are considered to include integrated navigation and primary flight displays with either aircraft attitude flight directors or Highway In The Sky (HITS) guidance with and without a synthetic depiction of the external visuals (i.e., synthetic vision). Relative to the first thrust, the results indicate that using an advanced display concept, as tested herein, low-time, non-instrument-rated pilots can exhibit flight-technical performance, subjective workload and situation awareness ratings as good as or better than high-time Instrument Flight Rules (IFR)-rated pilots using Baseline Round Dials for a nominal IMC approach. For the second thrust, the results indicate advanced VMC-like approaches are feasible in IMC, for all pilot groups tested for only the Synthetic Vision System (SVS) advanced display concept.
Final-Approach Spacing Aids (FASA) evaluation for terminal-area, time-based air traffic control
NASA Technical Reports Server (NTRS)
Credeur, Leonard; Capron, William R.; Lohr, Gary W.; Crawford, Daniel J.; Tang, Dershuen A.; Rodgers, William G., Jr.
1993-01-01
A jointly funded (NASA/FAA) real-time simulation study was conducted at NASA Langley Research Center to gather comparative performance data among three candidate final-approach spacing aid (FASA) display formats. Several objective measures of controller performance and their display eye-scan behavior as well as subjective workload and rating questionnaires were used. For each of two representative pattern-speed procedures (a 170-knot procedure and a 210-knot procedure with speed control aiding), data were gathered, via twelve FAA controllers, using four final-controller display format conditions (manual/ARTS 3, graphic marker, DICE countdown, and centerline slot marker). Measured runway separations were more precise with both the graphic marker and DICE countdown formats than with the centerline slot marker and both (graphic and DICE) improved precision relative to the manual/ARTS 3 format. For three separate rating criteria, the subject controllers ranked the FASA formats in the same order: graphic marker, DICE countdown, and centerline slot marker. The increased precision measured with the 210-knot pattern-speed procedure may indicate the potential for the application of speed-control aiding where higher pattern speeds are practical after the base-to-final turn. Also presented are key FASA issues, a rationale for the formats selected for testing, and their description.
Low-power circuits design for the wireless force measurement system of the total knee arthroplasty.
Chen, Hong; Liu, Ming; Wan, Weiyi; Jia, Chen; Zhang, Chun; Wang, Zihua
2010-01-01
This paper proposes a novel wireless force measurement system for the Total Knee Arthroplasty (TKA) to improve the ligament balancing procedure during TKA. The force measurement system is comprised of a Wireless Force Measurement Spacer (WFMS) and the display part. They communicate with each other by the Radio Frequency (RF) signal. The WFMS is designed to measure the force between the WFMS and the femoral component of the artificial implants and to transmit the force data wirelessly by a low power transceiver. The display part demonstrates the force data in 3D images in real time. The WFMS composes of a sensors array, a Universal Transducer Interfaces (UTIs) array, a low-power sub-threshold microprocessor and a transceiver. The sub-threshold 8-bit microprocessor is taped out with 0.18 microm CMOS technology. The testing results of the microprocessor show that the leakage power of 46nW and the dynamic power of 385nW@165kHz are achieved with the operating voltage of 350 mV. The test results of the system are given and the errors of the system are analyzed. The results verified the reliability of the system. The future work is to design the microprocessor and a lower power transceiver within a single chip.
DOT National Transportation Integrated Search
2014-09-09
Automatic Dependent Surveillance-Broadcast (ADS-B) In technology supports the display of traffic data on Cockpit Displays of Traffic Information (CDTIs). The data are used by flightcrews to perform defined self-separation procedures, such as the in-t...
Utility of an airframe referenced spatial auditory display for general aviation operations
NASA Astrophysics Data System (ADS)
Naqvi, M. Hassan; Wigdahl, Alan J.; Ranaudo, Richard J.
2009-05-01
The University of Tennessee Space Institute (UTSI) completed flight testing with an airframe-referenced localized audio cueing display. The purpose was to assess its affect on pilot performance, workload, and situational awareness in two scenarios simulating single-pilot general aviation operations under instrument meteorological conditions. Each scenario consisted of 12 test procedures conducted under simulated instrument meteorological conditions, half with the cue off, and half with the cue on. Simulated aircraft malfunctions were strategically inserted at critical times during each test procedure. Ten pilots participated in the study; half flew a moderate workload scenario consisting of point to point navigation and holding pattern operations and half flew a high workload scenario consisting of non precision approaches and missed approach procedures. Flight data consisted of aircraft and navigation state parameters, NASA Task Load Index (TLX) assessments, and post-flight questionnaires. With localized cues there was slightly better pilot technical performance, a reduction in workload, and a perceived improvement in situational awareness. Results indicate that an airframe-referenced auditory display has utility and pilot acceptance in general aviation operations.
Distributed augmented reality with 3-D lung dynamics--a planning tool concept.
Hamza-Lup, Felix G; Santhanam, Anand P; Imielińska, Celina; Meeks, Sanford L; Rolland, Jannick P
2007-01-01
Augmented reality (AR) systems add visual information to the world by using advanced display techniques. The advances in miniaturization and reduced hardware costs make some of these systems feasible for applications in a wide set of fields. We present a potential component of the cyber infrastructure for the operating room of the future: a distributed AR-based software-hardware system that allows real-time visualization of three-dimensional (3-D) lung dynamics superimposed directly on the patient's body. Several emergency events (e.g., closed and tension pneumothorax) and surgical procedures related to lung (e.g., lung transplantation, lung volume reduction surgery, surgical treatment of lung infections, lung cancer surgery) could benefit from the proposed prototype.
Pilot interaction with automated airborne decision making systems
NASA Technical Reports Server (NTRS)
Rouse, W. B.; Chu, Y. Y.; Greenstein, J. S.; Walden, R. S.
1976-01-01
An investigation was made of interaction between a human pilot and automated on-board decision making systems. Research was initiated on the topic of pilot problem solving in automated and semi-automated flight management systems and attempts were made to develop a model of human decision making in a multi-task situation. A study was made of allocation of responsibility between human and computer, and discussed were various pilot performance parameters with varying degrees of automation. Optimal allocation of responsibility between human and computer was considered and some theoretical results found in the literature were presented. The pilot as a problem solver was discussed. Finally the design of displays, controls, procedures, and computer aids for problem solving tasks in automated and semi-automated systems was considered.
NASA Technical Reports Server (NTRS)
Gille, Jennifer; Martin, Russel; Lubin, Jeffrey; Larimer, James
1995-01-01
In a series of papers presented in 1994, we examined the grayscale/resolution trade-off for natural images displayed on devices with discrete pixellation, such as AMLCD's. In the present paper we extend this study by examining the grayscale/resolution trade-off for text images on discrete-pixel displays. Halftoning in printing is an example of the grayscale/resolution trade-off. In printing, spatial resolution is sacrificed to produce grayscale. Another example of this trade-off is the inherent low-pass spatial filter of a CRT, caused by the point-spread function of the electron beam in the phosphor layer. On a CRT, sharp image edges are blurred by this inherent low-pass filtering, and the block noise created by spatial quantization is greatly reduced. A third example of this trade-off is text anti-aliasing, where grayscale is used to improve letter shape, size and location when rendered at a low spatial resolution. There are additional implications for display system design from the grayscale/resolution trade-off. For example, reduced grayscale can reduce system costs by requiring less complexity in the framestore, allowing the use of lower cost drivers, potentially increasing data transfer rates in the image subsystem, and simplifying the manufacturing processes that are used to construct the active matrix for AMLCD (active-matrix liquid-crystal display) or AMTFEL (active-matrix thin-film electroluminescent) devices. Therefore, the study of these trade-offs is important for display designers and manufacturing and systems engineers who wish to create the highest performance, lowest cost device possible. Our strategy for investigating this trade-off is to generate a set of simple test images, manipulate grayscale and resolution, predict discrimination performance using the ViDEOS(Sarnoff) Human Vision Model, conduct an empirical study of discrimination using psychophysical procedures, and verify the computational results using the psychophysical results.
Behavior changes after minor emergency procedures.
Brodzinski, Holly; Iyer, Srikant
2013-10-01
Procedures are common in pediatric emergency departments and frequently cause distress from pain and/or anxiety. The objective of this study was to describe the incidence, types, and magnitude of long-term behavior changes after procedures in the emergency setting. This is a descriptive pilot study to determine if children display negative behavioral changes after a minor emergency department procedure (abscess drainage or laceration repair). Behavior change was measured at 1 week by telephone follow-up using the 27-item Post Hospitalization Behavior Questionnaire, a well-validated instrument that measures behavior changes across 6 categories: general anxiety, separation anxiety, anxiety about sleep, eating disturbances, aggression toward authority, and apathy/withdrawal. Significant behavior change was defined as 5 or more negative behavior changes on the 27-item questionnaire. Twenty percent of children who underwent abscess drainage (n = 30) and 20% who underwent laceration repair (n = 30) displayed significant negative behavior change at 1 week. Children who displayed significant negative behavior change tended to be younger (3.6 vs 5.9 years) and trended toward being more likely to have received anxiolysis or sedation (16.7% vs 8.3%). Separation anxiety, sleep difficulties, and aggression toward authority were the most common behavior changes. In this pilot study, a significant percentage of children undergoing common emergency procedures exhibited an appreciable burden of negative behavior change at 1 week; these results demonstrate the need for further rigorous investigation of predictors of these changes and interventions, which can ameliorate these changes.
Equivalent retarder-rotator approach to on-state twisted nematic liquid crystal displays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duran, Vicente; Lancis, Jesus; Tajahuerce, Enrique
2006-06-01
Polarization properties of a twisted nematic liquid crystal cell are fully characterized by an equivalent optical system that consists of a retarder wave plate and a rotator. In this paper we show that this result is of interest to optimize the light-modulation capabilities of a voltage-addressed liquid crystal display (LCD). We provide two examples. First, we demonstrate a calibration method that can be carried out by a standard polarimetric technique with a high degree of precision. Second, we propose an optical device to generate a family of equiazimuth polarization states by adding a quarter-wave plate to the LCD. We findmore » that the design procedure is best described in geometrical terms on the Poincare sphere by use of the equivalent model. Finally, laboratory results corresponding to a commercial LCD are presented.« less
NASA Technical Reports Server (NTRS)
Lauber, J. K.; Bray, R. S.; Harrison, R. L.; Hemingway, J. C.; Scott, B. C.
1982-01-01
The advantages and disadvantages of head-up displays (HUDs) in commercial jet transport approach and landing operations was evaluated. Ten airline captains currently qualified in the B-727 aircraft flew a series of instrument landing system (ILS) and nonprecision approaches in a motion base simulator using both a flight director HUD concept and a flightpath HUD concept as well as conventional head-down instruments under a variety of environmental and operational conditions to assess: (1) the potential benefits of these HUDs in airline operations; (2) problems which might be associated with their use; and (3) flight crew training requirements and flight crew operating procedures suitable for use with the HUDs. Results are presented in terms of objective simulator based performance measures, subject pilot opinion and rating data, and observer data.
A perspective on the FAA approval process: Integrating rotorcraft displays, controls and workload
NASA Technical Reports Server (NTRS)
Green, David L.; Hart, Jake; Hwoschinsky, Peter
1993-01-01
The FAA is responsible for making the determination that a helicopter is safe for IFR operations in the National Airspace System (NAS). This involves objective and subjective evaluations of cockpit displays, flying qualities, procedures and human factors as they affect performance and workload. After all of the objective evaluations are completed, and all Federal Regulations have been met, FAA pilots make the final subjective judgement as to suitability for use by civil pilots in the NAS. The paper uses the flying qualities and pilot workload characteristics of a small helicopter to help examine the FAA pilot's involvement in this process. The result highlights the strengths of the process and its importance to the approval of new aircraft and equipments for civil IFR helicopter applications. The paper also identifies opportunities for improvement.
NASA Technical Reports Server (NTRS)
Prinzel, III, Lawrence J. (Inventor); Pope, Alan T. (Inventor); Williams, Steven P. (Inventor); Bailey, Randall E. (Inventor); Arthur, Jarvis J. (Inventor); Kramer, Lynda J. (Inventor); Schutte, Paul C. (Inventor)
2012-01-01
Embodiments of the invention permit flight paths (current and planned) to be viewed from various orientations to provide improved path and terrain awareness via graphical two-dimensional or three-dimensional perspective display formats. By coupling the flight path information with a terrain database, uncompromising terrain awareness relative to the path and ownship is provided. In addition, missed approaches, path deviations, and any navigational path can be reviewed and rehearsed before performing the actual task. By rehearsing a particular mission, check list items can be reviewed, terrain awareness can be highlighted, and missed approach procedures can be discussed by the flight crew. Further, the use of Controller Pilot Datalink Communications enables data-linked path, flight plan changes, and Air Traffic Control requests to be integrated into the flight display of the present invention.
NASA Technical Reports Server (NTRS)
Pachlhofer, Peter M.; Panek, Joseph W.; Dicki, Dennis J.; Piendl, Barry R.; Lizanich, Paul J.; Klann, Gary A.
2006-01-01
The Propulsion Systems Laboratory at the National Aeronautics and Space Administration (NASA) Glenn Research Center is one of the premier U.S. facilities for research on advanced aeropropulsion systems. The facility can simulate a wide range of altitude and Mach number conditions while supplying the aeropropulsion system with all the support services necessary to operate at those conditions. Test data are recorded on a combination of steady-state and highspeed data-acquisition systems. Recently a number of upgrades were made to the facility to meet demanding new requirements for the latest aeropropulsion concepts and to improve operational efficiency. Improvements were made to data-acquisition systems, facility and engine-control systems, test-condition simulation systems, video capture and display capabilities, and personnel training procedures. This paper discusses the facility s capabilities, recent upgrades, and planned future improvements.
Simulation Evaluation of Equivalent Vision Technologies for Aerospace Operations
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Williams, Steven P.; Wilz, Susan J.; Arthur, Jarvis J.
2009-01-01
A fixed-based simulation experiment was conducted in NASA Langley Research Center s Integration Flight Deck simulator to investigate enabling technologies for equivalent visual operations (EVO) in the emerging Next Generation Air Transportation System operating environment. EVO implies the capability to achieve or even improve on the safety of current-day Visual Flight Rules (VFR) operations, maintain the operational tempos of VFR, and perhaps even retain VFR procedures - all independent of the actual weather and visibility conditions. Twenty-four air transport-rated pilots evaluated the use of Synthetic/Enhanced Vision Systems (S/EVS) and eXternal Vision Systems (XVS) technologies as enabling technologies for future all-weather operations. The experimental objectives were to determine the feasibility of XVS/SVS/EVS to provide for all weather (visibility) landing capability without the need (or ability) for a visual approach segment and to determine the interaction of XVS/EVS and peripheral vision cues for terminal area and surface operations. Another key element of the testing investigated the pilot's awareness and reaction to non-normal events (i.e., failure conditions) that were unexpectedly introduced into the experiment. These non-normal runs served as critical determinants in the underlying safety of all-weather operations. Experimental data from this test are cast into performance-based approach and landing standards which might establish a basis for future all-weather landing operations. Glideslope tracking performance appears to have improved with the elimination of the approach visual segment. This improvement can most likely be attributed to the fact that the pilots didn't have to simultaneously perform glideslope corrections and find required visual landing references in order to continue a landing. Lateral tracking performance was excellent regardless of the display concept being evaluated or whether or not there were peripheral cues in the side window. Although workload ratings were significantly less when peripheral cues were present compared to when there were none, these differences appear to be operationally inconsequential. Larger display concepts tested in this experiment showed significant situation awareness (SA) improvements and workload reductions compared to smaller display concepts. With a fixed display size, a color display was more influential in SA and workload ratings than a collimated display.
Sleep-Effects on Implicit and Explicit Memory in Repeated Visual Search
Assumpcao, Leonardo; Gais, Steffen
2013-01-01
In repeated visual search tasks, facilitation of reaction times (RTs) due to repetition of the spatial arrangement of items occurs independently of RT facilitation due to improvements in general task performance. Whereas the latter represents typical procedural learning, the former is a kind of implicit memory that depends on the medial temporal lobe (MTL) memory system and is impaired in patients with amnesia. A third type of memory that develops during visual search is the observers’ explicit knowledge of repeated displays. Here, we used a visual search task to investigate whether procedural memory, implicit contextual cueing, and explicit knowledge of repeated configurations, which all arise independently from the same set of stimuli, are influenced by sleep. Observers participated in two experimental sessions, separated by either a nap or a controlled rest period. In each of the two sessions, they performed a visual search task in combination with an explicit recognition task. We found that (1) across sessions, MTL-independent procedural learning was more pronounced for the nap than rest group. This confirms earlier findings, albeit from different motor and perceptual tasks, showing that procedural memory can benefit from sleep. (2) Likewise, the sleep group compared with the rest group showed enhanced context-dependent configural learning in the second session. This is a novel finding, indicating that the MTL-dependent, implicit memory underlying contextual cueing is also sleep-dependent. (3) By contrast, sleep and wake groups displayed equivalent improvements in explicit recognition memory in the second session. Overall, the current study shows that sleep affects MTL-dependent as well as MTL-independent memory, but it affects different, albeit simultaneously acquired, forms of MTL-dependent memory differentially. PMID:23936363
STS-40 crewmembers use inflight blood collection system (IBCS) kit on middeck
NASA Technical Reports Server (NTRS)
1991-01-01
STS-40 crewmembers follow procedures for Experiment No. 261, The Influence of Space Flight on Erythrokinetics in Man, while on the middeck of Columbia, Orbiter Vehicle (OV) 102. Mission Specialist (MS) James P. Bagian (right) draws blood from Payload Specialist F. Drew Gaffney (center) as the second Spacelab Life Sciences 1 (SLS-1) Payload Specialist Millie Hughes-Fulford looks on. The crewmembers are using the inflight blood collection system (IBCS) kit in front of the forward lockers and the orbiter refrigerator freezer (ORF). Displayed on the forward lockers are decals representing the University of Tennessee, Colorado State, and Stanford University and several drink containers.
NASA Astrophysics Data System (ADS)
Kittle, David S.; Patil, Chirag G.; Mamelak, Adam; Hansen, Stacey; Perry, Jeff; Ishak, Laura; Black, Keith L.; Butte, Pramod V.
2016-03-01
Current surgical microscopes are limited in sensitivity for NIR fluorescence. Recent developments in tumor markers attached with NIR dyes require newer, more sensitive imaging systems with high resolution to guide surgical resection. We report on a small, single camera solution enabling advanced image processing opportunities previously unavailable for ultra-high sensitivity imaging of these agents. The system captures both visible reflectance and NIR fluorescence at 300 fps while displaying full HD resolution video at 60 fps. The camera head has been designed to easily mount onto the Zeiss Pentero microscope head for seamless integration into surgical procedures.
Portable Microcomputer Utilization for On-Line Pulmonary Testing
Pugh, R.; Fourre, J.; Karetzky, M.
1981-01-01
A host-remote pulmonary function testing system is described that is flexible, non-dedicated, inexpensive, and readily upgradable. It is applicable for laboratories considering computerization as well as for those which have converted to one of the already available but restricted systems. The remote unit has an 8 slot bus for memory, input-output boards, and an A-D converter. It has its own terminal for manual input and display of computed and measured data which is transmitted via an acoustic modem to a larger microcomputer. The program modules are written in Pascal-Z and/or the supplied Z-80 macro assembler as external procedures.
Dynamic optical projection of acquired luminescence for aiding oncologic surgery
NASA Astrophysics Data System (ADS)
Sarder, Pinaki; Gullicksrud, Kyle; Mondal, Suman; Sudlow, Gail P.; Achilefu, Samuel; Akers, Walter J.
2013-12-01
Optical imaging enables real-time visualization of intrinsic and exogenous contrast within biological tissues. Applications in human medicine have demonstrated the power of fluorescence imaging to enhance visualization in dermatology, endoscopic procedures, and open surgery. Although few optical contrast agents are available for human medicine at this time, fluorescence imaging is proving to be a powerful tool in guiding medical procedures. Recently, intraoperative detection of fluorescent molecular probes that target cell-surface receptors has been reported for improvement in oncologic surgery in humans. We have developed a novel system, optical projection of acquired luminescence (OPAL), to further enhance real-time guidance of open oncologic surgery. In this method, collected fluorescence intensity maps are projected onto the imaged surface rather than via wall-mounted display monitor. To demonstrate proof-of-principle for OPAL applications in oncologic surgery, lymphatic transport of indocyanine green was visualized in live mice for intraoperative identification of sentinel lymph nodes. Subsequently, peritoneal tumors in a murine model of breast cancer metastasis were identified using OPAL after systemic administration of a tumor-selective fluorescent molecular probe. These initial results clearly show that OPAL can enhance adoption and ease-of-use of fluorescence imaging in oncologic procedures relative to existing state-of-the-art intraoperative imaging systems.
Image standards in tissue-based diagnosis (diagnostic surgical pathology).
Kayser, Klaus; Görtler, Jürgen; Goldmann, Torsten; Vollmer, Ekkehard; Hufnagl, Peter; Kayser, Gian
2008-04-18
Progress in automated image analysis, virtual microscopy, hospital information systems, and interdisciplinary data exchange require image standards to be applied in tissue-based diagnosis. To describe the theoretical background, practical experiences and comparable solutions in other medical fields to promote image standards applicable for diagnostic pathology. THEORY AND EXPERIENCES: Images used in tissue-based diagnosis present with pathology-specific characteristics. It seems appropriate to discuss their characteristics and potential standardization in relation to the levels of hierarchy in which they appear. All levels can be divided into legal, medical, and technological properties. Standards applied to the first level include regulations or aims to be fulfilled. In legal properties, they have to regulate features of privacy, image documentation, transmission, and presentation; in medical properties, features of disease-image combination, human-diagnostics, automated information extraction, archive retrieval and access; and in technological properties features of image acquisition, display, formats, transfer speed, safety, and system dynamics. The next lower second level has to implement the prescriptions of the upper one, i.e. describe how they are implemented. Legal aspects should demand secure encryption for privacy of all patient related data, image archives that include all images used for diagnostics for a period of 10 years at minimum, accurate annotations of dates and viewing, and precise hardware and software information. Medical aspects should demand standardized patients' files such as DICOM 3 or HL 7 including history and previous examinations, information of image display hardware and software, of image resolution and fields of view, of relation between sizes of biological objects and image sizes, and of access to archives and retrieval. Technological aspects should deal with image acquisition systems (resolution, colour temperature, focus, brightness, and quality evaluation procedures), display resolution data, implemented image formats, storage, cycle frequency, backup procedures, operation system, and external system accessibility. The lowest third level describes the permitted limits and threshold in detail. At present, an applicable standard including all mentioned features does not exist to our knowledge; some aspects can be taken from radiological standards (PACS, DICOM 3); others require specific solutions or are not covered yet. The progress in virtual microscopy and application of artificial intelligence (AI) in tissue-based diagnosis demands fast preparation and implementation of an internationally acceptable standard. The described hierarchic order as well as analytic investigation in all potentially necessary aspects and details offers an appropriate tool to specifically determine standardized requirements.
Improving the color fidelity of cameras for advanced television systems
NASA Astrophysics Data System (ADS)
Kollarits, Richard V.; Gibbon, David C.
1992-08-01
In this paper we compare the accuracy of the color information obtained from television cameras using three and five wavelength bands. This comparison is based on real digital camera data. The cameras are treated as colorimeters whose characteristics are not linked to that of the display. The color matrices for both cameras were obtained by identical optimization procedures that minimized the color error The color error for the five band camera is 2. 5 times smaller than that obtained from the three band camera. Visual comparison of color matches on a characterized color monitor indicate that the five band camera is capable of color measurements that produce no significant visual error on the display. Because the outputs from the five band camera are reduced to the normal three channels conventionally used for display there need be no increase in signal handling complexity outside the camera. Likewise it is possible to construct a five band camera using only three sensors as in conventional cameras. The principal drawback of the five band camera is the reduction in effective camera sensitivity by about 3/4 of an I stop. 1.
Techniques for capturing expert knowledge - An expert systems/hypertext approach
NASA Technical Reports Server (NTRS)
Lafferty, Larry; Taylor, Greg; Schumann, Robin; Evans, Randy; Koller, Albert M., Jr.
1990-01-01
The knowledge-acquisition strategy developed for the Explosive Hazards Classification (EHC) Expert System is described in which expert systems and hypertext are combined, and broad applications are proposed. The EHC expert system is based on rapid prototyping in which primary knowledge acquisition from experts is not emphasized; the explosive hazards technical bulletin, technical guidance, and minimal interviewing are used to develop the knowledge-based system. Hypertext is used to capture the technical information with respect to four issues including procedural, materials, test, and classification issues. The hypertext display allows the integration of multiple knowlege representations such as clarifications or opinions, and thereby allows the performance of a broad range of tasks on a single machine. Among other recommendations, it is suggested that the integration of hypertext and expert systems makes the resulting synergistic system highly efficient.
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.
Podder, Tarun K; Beaulieu, Luc; Caldwell, Barrett; Cormack, Robert A; Crass, Jostin B; Dicker, Adam P; Fenster, Aaron; Fichtinger, Gabor; Meltsner, Michael A; Moerland, Marinus A; Nath, Ravinder; Rivard, Mark J; Salcudean, Tim; Song, Danny Y; Thomadsen, Bruce R; Yu, Yan
2014-10-01
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the applications of this technology have been in the implantation of seeds in patients with early-stage prostate cancer. Nevertheless, the techniques apply to any clinical site where interstitial brachytherapy is appropriate. In consideration of the rapid developments in this area, the American Association of Physicists in Medicine (AAPM) commissioned Task Group 192 to review the state-of-the-art in the field of robotic interstitial brachytherapy. This is a joint Task Group with the Groupe Européen de Curiethérapie-European Society for Radiotherapy & Oncology (GEC-ESTRO). All developed and reported robotic brachytherapy systems were reviewed. Commissioning and quality assurance procedures for the safe and consistent use of these systems are also provided. Manual seed placement techniques with a rigid template have an estimated in vivo accuracy of 3-6 mm. In addition to the placement accuracy, factors such as tissue deformation, needle deviation, and edema may result in a delivered dose distribution that differs from the preimplant or intraoperative plan. However, real-time needle tracking and seed identification for dynamic updating of dosimetry may improve the quality of seed implantation. The AAPM and GEC-ESTRO recommend that robotic systems should demonstrate a spatial accuracy of seed placement ≤1.0 mm in a phantom. This recommendation is based on the current performance of existing robotic brachytherapy systems and propagation of uncertainties. During clinical commissioning, tests should be conducted to ensure that this level of accuracy is achieved. These tests should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot-clinician and robot-patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.
System status display information
NASA Technical Reports Server (NTRS)
Summers, L. G.; Erickson, J. B.
1984-01-01
The system Status Display is an electronic display system which provides the flight crew with enhanced capabilities for monitoring and managing aircraft systems. Guidelines for the design of the electronic system displays were established. The technical approach involved the application of a system engineering approach to the design of candidate displays and the evaluation of a Hernative concepts by part-task simulation. The system engineering and selection of candidate displays are covered.
NASA Astrophysics Data System (ADS)
Brauer, U.
2007-08-01
The Open Navigator Framework (ONF) was developed to provide a unified and scalable platform for user interface integration. The main objective for the framework was to raise usability of monitoring and control consoles and to provide a reuse of software components in different application areas. ONF is currently applied for the Columbus onboard crew interface, the commanding application for the Columbus Control Centre, the Columbus user facilities specialized user interfaces, the Mission Execution Crew Assistant (MECA) study and EADS Astrium internal R&D projects. ONF provides a well documented and proven middleware for GUI components (Java plugin interface, simplified concept similar to Eclipse). The overall application configuration is performed within a graphical user interface for layout and component selection. The end-user does not have to work in the underlying XML configuration files. ONF was optimized to provide harmonized user interfaces for monitoring and command consoles. It provides many convenience functions designed together with flight controllers and onboard crew: user defined workspaces, incl. support for multi screens efficient communication mechanism between the components integrated web browsing and documentation search &viewing consistent and integrated menus and shortcuts common logging and application configuration (properties) supervision interface for remote plugin GUI access (web based) A large number of operationally proven ONF components have been developed: Command Stack & History: Release of commands and follow up the command acknowledges System Message Panel: Browse, filter and search system messages/events Unified Synoptic System: Generic synoptic display system Situational Awareness : Show overall subsystem status based on monitoring of key parameters System Model Browser: Browse mission database defintions (measurements, commands, events) Flight Procedure Executor: Execute checklist and logical flow interactive procedures Web Browser : Integrated browser reference documentation and operations data Timeline Viewer: View master timeline as Gantt chart Search: Local search of operations products (e.g. documentation, procedures, displays) All GUI components access the underlying spacecraft data (commanding, reporting data, events, command history) via a common library providing adaptors for the current deployments (Columbus MCS, Columbus onboard Data Management System, Columbus Trainer raw packet protocol). New Adaptors are easy to develop. Currently an adaptor to SCOS 2000 is developed as part of a study for the ESTEC standardization section ("USS for ESTEC Reference Facility").
Skill accreditation system for laparoscopic gastroenterologic surgeons in Japan.
Mori, Toshiyuki; Kimura, Taizo; Kitajima, Masaki
2010-01-01
The Japan Society for Endoscopic Surgery (JSES) has established an Endoscopic Surgical Skill Qualification System and started examination in 2004. Non-edited videotapes were assessed by two judges in a double-blinded fashion with strict criteria. Two kinds of criteria, namely common and procedure-specific, were prepared. The common criteria were designed to evaluate set-ups, autonomy of the operator, display of the surgical field, recognition of surgical anatomy, co-operation of the surgical team. The procedure-specific criteria were made to assess the operation in a step-by-step fashion. In total, out of 1.114 surgeons who were assessed by this qualification system over a period of four years, 537 (48.2%) have been accredited. The qualification rate in each surgical field has remained at the same level of 40 to 50% to date. Inter-rater agreement of two judges was low at 0.31 in the first year, but improved with revision of the criteria and consensus meetings. Surgeons assessed by this system as qualified experienced less frequent complications when compared to those who failed. This system has impacted on the improvement and standardization of laparoscopic surgery in Japan.
Design of high-fidelity haptic display for one-dimensional force reflection applications
NASA Astrophysics Data System (ADS)
Gillespie, Brent; Rosenberg, Louis B.
1995-12-01
This paper discusses the development of a virtual reality platform for the simulation of medical procedures which involve needle insertion into human tissue. The paper's focus is the hardware and software requirements for haptic display of a particular medical procedure known as epidural analgesia. To perform this delicate manual procedure, an anesthesiologist must carefully guide a needle through various layers of tissue using only haptic cues for guidance. As a simplifying aspect for the simulator design, all motions and forces involved in the task occur along a fixed line once insertion begins. To create a haptic representation of this procedure, we have explored both physical modeling and perceptual modeling techniques. A preliminary physical model was built based on CT-scan data of the operative site. A preliminary perceptual model was built based on current training techniques for the procedure provided by a skilled instructor. We compare and contrast these two modeling methods and discuss the implications of each. We select and defend the perceptual model as a superior approach for the epidural analgesia simulator.
ERIC Educational Resources Information Center
Debert, Paula; Huziwara, Edson M.; Faggiani, Robson Brino; de Mathis, Maria Eugenia Simoes; McIlvane, William J.
2009-01-01
Past research has demonstrated emergent conditional relations using a go/no-go procedure with pairs of figures displayed side-by-side on a computer screen. The present study sought to extend applications of this procedure. In Experiment 1, we evaluated whether emergent conditional relations could be demonstrated when two-component stimuli were…
Debert, Paula; Huziwara, Edson M; Faggiani, Robson Brino; De Mathis, Maria Eugênia Simões; McIlvane, William J
2009-09-01
Past research has demonstrated emergent conditional relations using a go/no-go procedure with pairs of figures displayed side-by-side on a computer screen. The present study sought to extend applications of this procedure. In Experiment 1, we evaluated whether emergent conditional relations could be demonstrated when two-component stimuli were displayed in figure-ground relationships-abstract figures displayed on backgrounds of different colors. Five normally capable adults participated. During training, each two-component stimulus was presented successively. Responses emitted in the presence of some stimulus pairs (A1B1, A2B2, A3B3, B1C1, B2C2 and B3C3) were reinforced, whereas responses emitted in the presence of other pairs (A1B2, A1B3, A2B1, A2B3, A3B1, A3B2, B1C2, B1C3, B2C1, B2C3, B3C1 and B3C2) were not. During tests, new configurations (AC and CA) were presented, thus emulating structurally the matching-to-sample tests employed in typical equivalence studies. All participants showed emergent relations consistent with stimulus equivalence during testing. In Experiment 2, we systematically replicated the procedures with stimulus compounds consisting of four figures (A1, A2, C1 and C2) and two locations (left - B1 and right - B2). All 6 normally capable adults exhibited emergent stimulus-stimulus relations. Together, these experiments show that the go/no-go procedure is a potentially useful alternative for studying emergent conditional relations when matching-to-sample is procedurally cumbersome or impossible to use.
Crew and Display Concepts Evaluation for Synthetic / Enhanced Vision Systems
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Kramer, Lynda J.; Prinzel, Lawrence J., III
2006-01-01
NASA s Synthetic Vision Systems (SVS) project is developing technologies with practical applications that strive to eliminate low-visibility conditions as a causal factor to civil aircraft accidents and replicate the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. Enhanced Vision System (EVS) technologies are analogous and complementary in many respects to SVS, with the principle difference being that EVS is an imaging sensor presentation, as opposed to a database-derived image. The use of EVS in civil aircraft is projected to increase rapidly as the Federal Aviation Administration recently changed the aircraft operating rules under Part 91, revising the flight visibility requirements for conducting operations to civil airports. Operators conducting straight-in instrument approach procedures may now operate below the published approach minimums when using an approved EVS that shows the required visual references on the pilot s Head-Up Display. An experiment was conducted to evaluate the complementary use of SVS and EVS technologies, specifically focusing on new techniques for integration and/or fusion of synthetic and enhanced vision technologies and crew resource management while operating under the newly adopted FAA rules which provide operating credit for EVS. Overall, the experimental data showed that significant improvements in SA without concomitant increases in workload and display clutter could be provided by the integration and/or fusion of synthetic and enhanced vision technologies for the pilot-flying and the pilot-not-flying.
NASA Astrophysics Data System (ADS)
Zamorano, Lucia J.; Dujovny, Manuel; Ausman, James I.
1990-01-01
"Real time" surgical treatment planning utilizing multimodality imaging (CT, MRI, DA) has been developed to provide the neurosurgeon with 2D multiplanar and 3D views of a patient's lesion for stereotactic planning. Both diagnostic and therapeutic stereotactic procedures have been implemented utilizing workstation (SUN 1/10) and specially developed software and hardware (developed in collaboration with TOMO Medical Imaging Technology, Southfield, MI). This provides complete 3D and 2D free-tilt views as part of the system instrumentation. The 2D Multiplanar includes reformatted sagittal, coronal, paraaxial and free tilt oblique vectors at any arbitrary plane of the patient's lesion. The 3D includes features for extracting a view of the target volume localized by a process including steps of automatic segmentation, thresholding, and/or boundary detection with 3D display of the volumes of interest. The system also includes the capability of interactive playback of reconstructed 3D movies, which can be viewed at any hospital network having compatible software on strategical locations or at remote sites through data transmission and record documentation by image printers. Both 2D and 3D menus include real time stereotactic coordinate measurements and trajectory definition capabilities as well as statistical functions for computing distances, angles, areas, and volumes. A combined interactive 3D-2D multiplanar menu allows simultaneous display of selected trajectory, final optimization, and multiformat 2D display of free-tilt reformatted images perpendicular to selected trajectory of the entire target volume.
5-inch-size liquid crystal flat panel display evaluation test by flight simulator
NASA Astrophysics Data System (ADS)
Kawahara, Hiroyasu; Watanabe, Akira; Wakairo, Kaoru; Udagawa, Tomoyuki; Kurihara, Yoichiro
An evaluation test is conducted on the function, performance, and display format of a 5x5 inch flat panel display (FPD) in a flight simulator. The FPD utilizes a color liquid crystal panel that is compact and lightweight and has excellent visibility. The simulator evaluation test is carried out in sequence with the conventional takeoff and landing to altitude, and then conversion to STOL procedures for flight path and subsequent approach and landing. It is shown that the liquid crystal display could be employed as a satisfactory indicator for aircraft instrumentation.
Rana, V K; Rudin, S; Bednarek, D R
2016-09-01
Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.
Rana, V. K.; Rudin, S.; Bednarek, D. R.
2016-01-01
Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries. PMID:27587043
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rana, V. K., E-mail: vkrana@buffalo.edu
Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, amore » data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.« less
Augmented microscopy with near-infrared fluorescence detection
NASA Astrophysics Data System (ADS)
Watson, Jeffrey R.; Martirosyan, Nikolay; Skoch, Jesse; Lemole, G. Michael; Anton, Rein; Romanowski, Marek
2015-03-01
Near-infrared (NIR) fluorescence has become a frequently used intraoperative technique for image-guided surgical interventions. In procedures such as cerebral angiography, surgeons use the optical surgical microscope for the color view of the surgical field, and then switch to an electronic display for the NIR fluorescence images. However, the lack of stereoscopic, real-time, and on-site coregistration adds time and uncertainty to image-guided surgical procedures. To address these limitations, we developed the augmented microscope, whereby the electronically processed NIR fluorescence image is overlaid with the anatomical optical image in real-time within the optical path of the microscope. In vitro, the augmented microscope can detect and display indocyanine green (ICG) concentrations down to 94.5 nM, overlaid with the anatomical color image. We prepared polyacrylamide tissue phantoms with embedded polystyrene beads, yielding scattering properties similar to brain matter. In this model, 194 μM solution of ICG was detectable up to depths of 5 mm. ICG angiography was then performed in anesthetized rats. A dynamic process of ICG distribution in the vascular system overlaid with anatomical color images was observed and recorded. In summary, the augmented microscope demonstrates NIR fluorescence detection with superior real-time coregistration displayed within the ocular of the stereomicroscope. In comparison to other techniques, the augmented microscope retains full stereoscopic vision and optical controls including magnification and focus, camera capture, and multiuser access. Augmented microscopy may find application in surgeries where the use of traditional microscopes can be enhanced by contrast agents and image guided delivery of therapeutics, including oncology, neurosurgery, and ophthalmology.
Astronauts Gibson and Pogue at Apollo Telescope Mount display/control panel
1973-09-10
S73-32837 (10 Sept. 1973) --- Scientist-astronaut Edward G. Gibson, seated, and astronaut William R. Pogue discuss a mission procedure at the Apollo Telescope Mount (ATM) display and control panel mock-up in the one-G trainer for the Multiple Docking Adapter (MDA) at Johnson Space Center. Photo credit: NASA
46 CFR 502.991 - OMB control numbers assigned pursuant to the Paperwork Reduction Act.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROVISIONS RULES OF PRACTICE AND PROCEDURE Paperwork Reduction Act § 502.991 OMB control numbers assigned pursuant to the Paperwork Reduction Act. This section displays the control numbers assigned to information... comply with the Act, which requires that agencies display a current control number assigned by the...
39 CFR 3001.117 - Posting of documents by Postal Service for inspection by affected postal patrons.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PERSONNEL RULES OF PRACTICE AND PROCEDURE Rules Applicable to Appeals of Postal Service Determinations To... cause to be displayed prominently, in the post office or offices serving the patrons affected by the... display prominently any such document shall be deemed sufficient reason to suspend the effectiveness of...
The Trifold Display Board: A Visual and Portable Way to Present Physical Education Class Information
ERIC Educational Resources Information Center
Lavay, Barry; Alexander, Susan; Lawrence, Barbara
2008-01-01
Physical educators at all grade levels often provide instruction in open environments and classrooms without walls, such as gymnasiums, school playgrounds and athletic fields. Open teaching environments present unique challenges when it comes to implementing and displaying class information such as class schedules, routines and procedures, rules…
Out with the old? The role of selective attention in retaining targets in partial report.
Lindsey, Dakota R B; Bundesen, Claus; Kyllingsbæk, Søren; Petersen, Anders; Logan, Gordon D
2017-01-01
In the partial-report task, subjects are asked to report only a portion of the items presented. Selective attention chooses which objects to represent in short-term memory (STM) on the basis of their relevance. Because STM is limited in capacity, one must sometimes choose which objects are removed from memory in light of new relevant information. We tested the hypothesis that the choices among newly presented information and old information in STM involve the same process-that both are acts of selective attention. We tested this hypothesis using a two-display partial-report procedure. In this procedure, subjects had to select and retain relevant letters (targets) from two sequentially presented displays. If selection in perception and retention in STM are the same process, then irrelevant letters (distractors) in the second display, which demanded attention because of their similarity to the targets, should have decreased target report from the first display. This effect was not obtained in any of four experiments. Thus, choosing objects to keep in STM is not the same process as choosing new objects to bring into STM.
Real-Time Imaging System for the OpenPET
NASA Astrophysics Data System (ADS)
Tashima, Hideaki; Yoshida, Eiji; Kinouchi, Shoko; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Suga, Mikio; Haneishi, Hideaki; Yamaya, Taiga
2012-02-01
The OpenPET and its real-time imaging capability have great potential for real-time tumor tracking in medical procedures such as biopsy and radiation therapy. For the real-time imaging system, we intend to use the one-pass list-mode dynamic row-action maximum likelihood algorithm (DRAMA) and implement it using general-purpose computing on graphics processing units (GPGPU) techniques. However, it is difficult to make consistent reconstructions in real-time because the amount of list-mode data acquired in PET scans may be large depending on the level of radioactivity, and the reconstruction speed depends on the amount of the list-mode data. In this study, we developed a system to control the data used in the reconstruction step while retaining quantitative performance. In the proposed system, the data transfer control system limits the event counts to be used in the reconstruction step according to the reconstruction speed, and the reconstructed images are properly intensified by using the ratio of the used counts to the total counts. We implemented the system on a small OpenPET prototype system and evaluated the performance in terms of the real-time tracking ability by displaying reconstructed images in which the intensity was compensated. The intensity of the displayed images correlated properly with the original count rate and a frame rate of 2 frames per second was achieved with average delay time of 2.1 s.
Computer aided diagnosis and treatment planning for developmental dysplasia of the hip
NASA Astrophysics Data System (ADS)
Li, Bin; Lu, Hongbing; Cai, Wenli; Li, Xiang; Meng, Jie; Liang, Zhengrong
2005-04-01
The developmental dysplasia of the hip (DDH) is a congenital malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Early diagnosis and treatment is important because failure to diagnose and improper treatment can result in significant morbidity. In this paper, we designed and implemented a computer aided system for the diagnosis and treatment planning of this disease. With the design, the patient received CT (computed tomography) or MRI (magnetic resonance imaging) scan first. A mixture-based PV partial-volume algorithm was applied to perform bone segmentation on CT image, followed by three-dimensional (3D) reconstruction and display of the segmented image, demonstrating the special relationship between the acetabulum and femurs for visual judgment. Several standard procedures, such as Salter procedure, Pemberton procedure and Femoral Shortening osteotomy, were simulated on the screen to rehearse a virtual treatment plan. Quantitative measurement of Acetabular Index (AI) and Femoral Neck Anteversion (FNA) were performed on the 3D image for evaluation of DDH and treatment plans. PC graphics-card GPU architecture was exploited to accelerate the 3D rendering and geometric manipulation. The prototype system was implemented on PC/Windows environment and is currently under clinical trial on patient datasets.
An object-oriented class library for medical software development.
O'Kane, K C; McColligan, E E
1996-12-01
The objective of this research is the development of a Medical Object Library (MOL) consisting of reusable, inheritable, portable, extendable C++ classes that facilitate rapid development of medical software at reduced cost and increased functionality. The result of this research is a library of class objects that range in function from string and hierarchical file handling entities to high level, procedural agents that perform increasingly complex, integrated tasks. A system built upon these classes is compatible with any other system similarly constructed with respect to data definitions, semantics, data organization and storage. As new objects are built, they can be added to the class library for subsequent use. The MOL is a toolkit of software objects intended to support a common file access methodology, a unified medical record structure, consistent message processing, standard graphical display facilities and uniform data collection procedures. This work emphasizes the relationship that potentially exists between the structure of a hierarchical medical record and procedural language components by means of a hierarchical class library and tree structured file access facility. In doing so, it attempts to establish interest in and demonstrate the practicality of the hierarchical medical record model in the modern context of object oriented programming.
Deng, Lei; Linero, Florencia; Saelens, Xavier
2016-01-01
Viruslike particles often combine high physical stability with robust immunogenicity. Furthermore, when such particles are based on bacteriophages, they can be produced in high amounts at minimal cost and typically will require only standard biologically contained facilities. We provide protocols for the characterization and purification of recombinant viruslike particles derived from filamentous bacteriophages. As an example, we focus on filamentous Escherichia coli fd phage displaying a conserved influenza A virus epitope that is fused genetically to the N-terminus of the major coat protein of this phage. A step-by-step procedure to obtain a high-titer, pure recombinant phage preparation is provided. We also describe a quality control experiment based on a biological readout of the purified fd phage preparation. These protocols together with the highlighted critical steps may facilitate generic implementation of the provided procedures for the display of other epitopes by recombinant fd phages.
Effects on locomotion and memory in 2 models of cerebral hypoperfusion in male Wistar rats.
Martínez-Díaz, J A; García, L I; Hernández, M E; Aranda-Abreu, G E
2015-09-01
Cerebral ischaemia is one of the most common neurological diseases worldwide. Its many sequelae range from motor and sensory symptoms to cognitive decline and dementia. Animal models of cerebral ischaemia/hypoperfusion elicit effects on long term memory; however, the effects of these procedures on short term memory are not clearly understood and effects induced by alternative hypoperfusion models are completely unknown. We evaluated the effects of 2 cerebral hyperperfusion models on memory in 3-month-old male rats. Episodic memory and working memory were assessed using the new object recognition test and the spontaneous alteration test, respectively. Neurological assessment was also performed, along with an open field test to evaluate locomotor activity. Rats in both hyperperfusion models displayed no cognitive changes. Rats with unilateral left-sided ligation plus temporary ligation of the right carotid tended to show slightly impaired performance on the new object recognition test on the second day after the procedure. In contrast, the group with permanent unilateral ligation tended to display alterations in working and episodic memory 9 days after the procedure, but they subsequently recovered. Despite these differences, both hypoperfusion groups displayed clear signs of motor impairment 2 days after the procedure, as reflected by their decreased locomotor activity during the open field test. Copyright © 2014 Sociedad Española de Neurología. Published by Elsevier España, S.L.U. All rights reserved.
Resource Document for the Design of Electronic Instrument Approach Procedure Displays
DOT National Transportation Integrated Search
1995-03-01
Instrument approach procedure (IAP) charts play a large role in contributing to the success or failure of approaches and : landings. Paper IAP charts have been criticized for excessive clutter, for text sizes that are too small to read, and : for ina...
21 CFR 352.50 - Principal display panel of all sunscreen drug products.
Code of Federal Regulations, 2013 CFR
2013-04-01
... sunscreen product testing procedures in § 352.76. (1) (Select one of the following: “Water,” “Water/Sweat... product testing procedures in § 352.76. (1) “Very” (select one of the following: “Water,” “Water/Sweat...
21 CFR 352.50 - Principal display panel of all sunscreen drug products.
Code of Federal Regulations, 2012 CFR
2012-04-01
... sunscreen product testing procedures in § 352.76. (1) (Select one of the following: “Water,” “Water/Sweat... product testing procedures in § 352.76. (1) “Very” (select one of the following: “Water,” “Water/Sweat...
21 CFR 352.50 - Principal display panel of all sunscreen drug products.
Code of Federal Regulations, 2014 CFR
2014-04-01
... sunscreen product testing procedures in § 352.76. (1) (Select one of the following: “Water,” “Water/Sweat... product testing procedures in § 352.76. (1) “Very” (select one of the following: “Water,” “Water/Sweat...
21 CFR 352.50 - Principal display panel of all sunscreen drug products.
Code of Federal Regulations, 2011 CFR
2011-04-01
... sunscreen product testing procedures in § 352.76. (1) (Select one of the following: “Water,” “Water/Sweat... product testing procedures in § 352.76. (1) “Very” (select one of the following: “Water,” “Water/Sweat...
21 CFR 352.50 - Principal display panel of all sunscreen drug products.
Code of Federal Regulations, 2010 CFR
2010-04-01
... sunscreen product testing procedures in § 352.76. (1) (Select one of the following: “Water,” “Water/Sweat... product testing procedures in § 352.76. (1) “Very” (select one of the following: “Water,” “Water/Sweat...
Lahmar, Aida; Akcan, Tolga; Chekir-Ghedira, Leila; Estévez, Mario
2018-04-01
The present study provides molecular insight into the effect of thymol and carvacrol on the oxidative damage caused to myofibrillar proteins by a hydroxyl-radical generating system (HRGS). An innovative model system was designed, in which gels, prepared with increasing levels of myofibrillar proteins, were oxidized by a HRGS (Fe 3+ /H 2 O 2 , 60 °C and 7 days) in the presence of lipids. The molecular affinity between myofibrillar proteins and both terpenes, as well as their effect on the oxidative stability of the gel systems, were studied using a non-destructive and solvent-free procedure based on fluorescence spectroscopy. Carvacrol displayed more affinity than thymol for establishing chemical interactions with protein residues. Both terpenes exhibited a significant antioxidant potential against the generation of lipid-derived volatile carbonyls and against the formation of protein crosslinking. This procedure may be applied to meat products to assess the effectiveness of a given antioxidant additive without size reduction or sample processing. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sun, Yue; Ban, Bhupal; Bradbury, Andrew; ...
2016-08-29
The development of antibodies to low molecular weight haptens remains challenging due to both the low immunogenicity of many haptens and the cross-reactivity of the protein carriers used to generate the immune response. Recombinant antibodies and novel display technologies have greatly advanced antibody development; however, new techniques are still required to select rare hapten-specific antibodies from large recombinant libraries. In the present study, we used a combination of phage and yeast display to screen an immune antibody library (size, 4.4 × 10 6 ) against hapten markers for petroleum contamination (phenanthrene and methylphenanthrenes). Selection via phage display was used firstmore » to enrich the library between 20- and 100- fold for clones that bound to phenanthrene-protein conjugates. The enriched libraries were subsequently transferred to a yeast display system and a newly developed competitive FACS procedure was employed to select rare hapten-specific clones. Competitive FACS increased the frequency of hapten-specific scFvs in our yeast-displayed scFvs from 0.025 to 0.005% in the original library to between 13 and 35% in selected pools. The presence of hapten-specific scFvs was confirmed by competitive ELISA using periplasmic protein. Three distinct antibody clones that recognize phenanthrene and methylphenanthrenes were selected, and their distinctive binding properties were characterized. To our knowledge, these are first antibodies that can distinguish between methylated (petrogenic) versus unmethylated (pyrogenic) phenanthrenes; such antibodies will be useful in detecting the sources of environmental contamination. Furthermore, this selection method could be generally adopted in the selection of other hapten-specific recombinant antibodies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yue; Ban, Bhupal; Bradbury, Andrew
The development of antibodies to low molecular weight haptens remains challenging due to both the low immunogenicity of many haptens and the cross-reactivity of the protein carriers used to generate the immune response. Recombinant antibodies and novel display technologies have greatly advanced antibody development; however, new techniques are still required to select rare hapten-specific antibodies from large recombinant libraries. In the present study, we used a combination of phage and yeast display to screen an immune antibody library (size, 4.4 × 10 6 ) against hapten markers for petroleum contamination (phenanthrene and methylphenanthrenes). Selection via phage display was used firstmore » to enrich the library between 20- and 100- fold for clones that bound to phenanthrene-protein conjugates. The enriched libraries were subsequently transferred to a yeast display system and a newly developed competitive FACS procedure was employed to select rare hapten-specific clones. Competitive FACS increased the frequency of hapten-specific scFvs in our yeast-displayed scFvs from 0.025 to 0.005% in the original library to between 13 and 35% in selected pools. The presence of hapten-specific scFvs was confirmed by competitive ELISA using periplasmic protein. Three distinct antibody clones that recognize phenanthrene and methylphenanthrenes were selected, and their distinctive binding properties were characterized. To our knowledge, these are first antibodies that can distinguish between methylated (petrogenic) versus unmethylated (pyrogenic) phenanthrenes; such antibodies will be useful in detecting the sources of environmental contamination. Furthermore, this selection method could be generally adopted in the selection of other hapten-specific recombinant antibodies.« less
Platform for intraoperative analysis of video streams
NASA Astrophysics Data System (ADS)
Clements, Logan; Galloway, Robert L., Jr.
2004-05-01
Interactive, image-guided surgery (IIGS) has proven to increase the specificity of a variety of surgical procedures. However, current IIGS systems do not compensate for changes that occur intraoperatively and are not reflected in preoperative tomograms. Endoscopes and intraoperative ultrasound, used in minimally invasive surgery, provide real-time (RT) information in a surgical setting. Combining the information from RT imaging modalities with traditional IIGS techniques will further increase surgical specificity by providing enhanced anatomical information. In order to merge these techniques and obtain quantitative data from RT imaging modalities, a platform was developed to allow both the display and processing of video streams in RT. Using a Bandit-II CV frame grabber board (Coreco Imaging, St. Laurent, Quebec) and the associated library API, a dynamic link library was created in Microsoft Visual C++ 6.0 such that the platform could be incorporated into the IIGS system developed at Vanderbilt University. Performance characterization, using two relatively inexpensive host computers, has shown the platform capable of performing simple image processing operations on frames captured from a CCD camera and displaying the processed video data at near RT rates both independent of and while running the IIGS system.
NASA Johnson Space Center Usability Testing and Analysis facility (UTAF) Overview
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Holden, Kritina L.
2005-01-01
The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility performs research for NASA's HumanSystems Integration Program, under the HumanSystems Research and Technology Division. Specifically, the UTAF provides human factors support for space vehicles, including the International Space Station, the Space Shuttle, and the forthcoming Crew Exploration Vehicle. In addition, there are ongoing collaborative research efforts with external corporations and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes and requirements. This presentation will provide an overview of ongoing activities, and will address how the UTAF projects will evolve to meet new space initiatives.
A portable high-definition electronic endoscope based on embedded system
NASA Astrophysics Data System (ADS)
Xu, Guang; Wang, Liqiang; Xu, Jin
2012-11-01
This paper presents a low power and portable highdefinition (HD) electronic endoscope based on CortexA8 embedded system. A 1/6 inch CMOS image sensor is used to acquire HD images with 1280 *800 pixels. The camera interface of A8 is designed to support images of various sizes and support multiple inputs of video format such as ITUR BT601/ 656 standard. Image rotation (90 degrees clockwise) and image process functions are achieved by CAMIF. The decode engine of the processor plays back or records HD videos at speed of 30 frames per second, builtin HDMI interface transmits high definition images to the external display. Image processing procedures such as demosaicking, color correction and auto white balance are realized on the A8 platform. Other functions are selected through OSD settings. An LCD panel displays the real time images. The snapshot pictures or compressed videos are saved in an SD card or transmited to a computer through USB interface. The size of the camera head is 4×4.8×15 mm with more than 3 meters working distance. The whole endoscope system can be powered by a lithium battery, with the advantages of miniature, low cost and portability.
NASA Technical Reports Server (NTRS)
Prinzel, Lawrence J., III; Shelton, Kevin J.; Kramer, Lynda J.; Arthur, Jarvis J.; Bailey, Randall E.; Norman, Rober M.; Ellis, Kyle K. E.; Barmore, Bryan E.
2011-01-01
An emerging Next Generation Air Transportation System concept - Equivalent Visual Operations (EVO) - can be achieved using an electronic means to provide sufficient visibility of the external world and other required flight references on flight deck displays that enable the safety, operational tempos, and visual flight rules (VFR)-like procedures for all weather conditions. Synthetic and enhanced flight vision system technologies are critical enabling technologies to EVO. Current research evaluated concepts for flight deck-based interval management (FIM) operations, integrated with Synthetic Vision and Enhanced Vision flight-deck displays and technologies. One concept involves delegated flight deck-based separation, in which the flight crews were paired with another aircraft and responsible for spacing and maintaining separation from the paired aircraft, termed, "equivalent visual separation." The operation required the flight crews to acquire and maintain an "equivalent visual contact" as well as to conduct manual landings in low-visibility conditions. The paper describes results that evaluated the concept of EVO delegated separation, including an off-nominal scenario in which the lead aircraft was not able to conform to the assigned spacing resulting in a loss of separation.
Systems workplace for endoscopic surgery.
Irion, K M; Novak, P
2000-01-01
With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.
Mursch, K; Gotthardt, T; Kröger, R; Bublat, M; Behnke-Mursch, J
2005-08-01
We evaluated an advanced concept for patient-based navigation during minimally invasive neurosurgical procedures. An infrared-based, off-line neuro-navigation system (LOCALITE, Bonn, Germany) was applied during operations within a 0.5 T intraoperative MRI scanner (iMRI) (Signa SF, GE Medical Systems, Milwaukee, WI, USA) in addition to the conventional real-time system. The three-dimensional (3D) data set was acquired intraoperatively and up-dated when brain-shift was suspected. Twenty-three patients with subcortical lesions were operated upon with the aim to minimise the operative trauma. Small craniotomies (median diameter 30 mm, mean diameter 27 mm) could be placed exactly. In all cases, the primary goal of the operation (total resection or biopsy) was achieved in a straightforward procedure without permanent morbidity. The navigation system could be easily used without technical problems. In contrast to the real-time navigation mode of the MR system, the higher quality as well as the real-time display of the MR images reconstructed from the 3D reference data provided sufficient visual-manual coordination. The system combines the advantages of conventional neuro-navigation with the ability to adapt intraoperatively to the continuously changing anatomy. Thus, small and/or deep lesions can be operated upon in straightforward minimally invasive operations.
Computer-assisted navigation in orthopedic surgery.
Mavrogenis, Andreas F; Savvidou, Olga D; Mimidis, George; Papanastasiou, John; Koulalis, Dimitrios; Demertzis, Nikolaos; Papagelopoulos, Panayiotis J
2013-08-01
Computer-assisted navigation has a role in some orthopedic procedures. It allows the surgeons to obtain real-time feedback and offers the potential to decrease intra-operative errors and optimize the surgical result. Computer-assisted navigation systems can be active or passive. Active navigation systems can either perform surgical tasks or prohibit the surgeon from moving past a predefined zone. Passive navigation systems provide intraoperative information, which is displayed on a monitor, but the surgeon is free to make any decisions he or she deems necessary. This article reviews the available types of computer-assisted navigation, summarizes the clinical applications and reviews the results of related series using navigation, and informs surgeons of the disadvantages and pitfalls of computer-assisted navigation in orthopedic surgery. Copyright 2013, SLACK Incorporated.
NASA Technical Reports Server (NTRS)
Grove, R. D.; Mayhew, S. C.
1973-01-01
A computer program (Langley program C1123) has been developed for estimating aircraft stability and control parameters from flight test data. These parameters are estimated by the maximum likelihood estimation procedure implemented on a real-time digital simulation system, which uses the Control Data 6600 computer. This system allows the investigator to interact with the program in order to obtain satisfactory results. Part of this system, the control and display capabilities, is described for this program. This report also describes the computer program by presenting the program variables, subroutines, flow charts, listings, and operational features. Program usage is demonstrated with a test case using pseudo or simulated flight data.
NASA Technical Reports Server (NTRS)
Tappa, M. J.; Simon, J. I; Jordan, M. K.; Young, E. D.
2015-01-01
Many elements display both linear (mass-dependent) and non-linear (mass-independent) isotope anomalies (relative to a common reservoir). In early Solar System objects, with the exception of oxygen, mass-dependent isotope anomalies are most commonly thought to result from phase separation processes such as evaporation and condensation, whereas many mass-independent isotope anomalies likely reflect radiogenic ingrowth or incomplete mixing of presolar components in the proto-planetary disk. Coupling the isotopic characterization of multiple elements with differing volatilities in single objects may provide information regarding the location, source material, and/or processes involved in the formation of early Solar System solids. Here, we follow up on the work presented in, and detail new procedures developed to make high-precision multi-isotope measurements of Calcium, Chromium, and Titanium with small or limited amounts of sample using thermal ionization mass spectrometry and multi-collector ICP-MS, and characterize a suite of chondritic and terrestrial standards.
Use of an engineering data management system in the analysis of space shuttle orbiter tiles
NASA Technical Reports Server (NTRS)
Giles, G. L.; Vallas, M.
1981-01-01
The use of an engineering data management system to facilitate the extensive stress analyses of the space shuttle orbiter thermal protection system is demonstrated. The methods used to gather, organize, and store the data; to query data interactively; to generate graphic displays of the data; and to access, transform, and prepare the data for input to a stress analysis program are described. Information related to many separate tiles can be accessed individually from the data base which has a natural organization from an engineering viewpoint. The flexible user features of the system facilitate changes in data content and organization which occur during the development and refinement of the tile analysis procedure. Additionally, the query language supports retrieval of data to satisfy a variety of user-specified conditions.
NASA Technical Reports Server (NTRS)
Bodley, C. S.; Devers, A. D.; Park, A. C.
1975-01-01
Analytical procedures and digital computer code are presented for the dynamic analysis of a flexible spacecraft with rotating components. Topics, considered include: (1) nonlinear response in the time domain, and (2) linear response in the frequency domain. The spacecraft is assumed to consist of an assembly of connected rigid or flexible subassemblies. The total system is not restricted to a topological connection arrangement and may be acting under the influence of passive or active control systems and external environments. The analytics and associated digital code provide the user with the capability to establish spacecraft system nonlinear total response for specified initial conditions, linear perturbation response about a calculated or specified nominal motion, general frequency response and graphical display, and spacecraft system stability analysis.
A new database sub-system for grain-size analysis
NASA Astrophysics Data System (ADS)
Suckow, Axel
2013-04-01
Detailed grain-size analyses of large depth profiles for palaeoclimate studies create large amounts of data. For instance (Novothny et al., 2011) presented a depth profile of grain-size analyses with 2 cm resolution and a total depth of more than 15 m, where each sample was measured with 5 repetitions on a Beckman Coulter LS13320 with 116 channels. This adds up to a total of more than four million numbers. Such amounts of data are not easily post-processed by spreadsheets or standard software; also MS Access databases would face serious performance problems. The poster describes a database sub-system dedicated to grain-size analyses. It expands the LabData database and laboratory management system published by Suckow and Dumke (2001). This compatibility with a very flexible database system provides ease to import the grain-size data, as well as the overall infrastructure of also storing geographic context and the ability to organize content like comprising several samples into one set or project. It also allows easy export and direct plot generation of final data in MS Excel. The sub-system allows automated import of raw data from the Beckman Coulter LS13320 Laser Diffraction Particle Size Analyzer. During post processing MS Excel is used as a data display, but no number crunching is implemented in Excel. Raw grain size spectra can be exported and controlled as Number- Surface- and Volume-fractions, while single spectra can be locked for further post-processing. From the spectra the usual statistical values (i.e. mean, median) can be computed as well as fractions larger than a grain size, smaller than a grain size, fractions between any two grain sizes or any ratio of such values. These deduced values can be easily exported into Excel for one or more depth profiles. However, such a reprocessing for large amounts of data also allows new display possibilities: normally depth profiles of grain-size data are displayed only with summarized parameters like the clay content, sand content, etc., which always only displays part of the available information at each depth. Alternatively, full spectra were displayed at one depth. The new software now allows to display the whole grain-size spectrum at each depth in a three dimensional display. LabData and the grain-size subsystem are based on MS Access as front-end and MS SQL Server as back-end database systems. The SQL code for the data model, SQL server procedures and triggers and the MS Access basic code for the front end are public domain code, published under the GNU GPL license agreement and are available free of charge. References: Novothny, Á., Frechen, M., Horváth, E., Wacha, L., Rolf, C., 2011. Investigating the penultimate and last glacial cycles of the Sütt dating, high-resolution grain size, and magnetic susceptibility data. Quaternary International 234, 75-85. Suckow, A., Dumke, I., 2001. A database system for geochemical, isotope hydrological and geochronological laboratories. Radiocarbon 43, 325-337.
Use of asymptotic methods in vibration analysis
NASA Technical Reports Server (NTRS)
Ashley, H.
1978-01-01
The derivation of dynamic differential equations, suitable for studying the vibrations of rotating, curved, slender structures was examined, and the Hamiltonian procedure was advocated for this purpose. Various reductions of the full system are displayed, which govern the vibrating troposkien when various order of magnitude restrictions are placed on important parameters. Possible advantages of the WKB asymptotic method for solving these classes of problems are discussed. A special case of this method is used illustratively to calculate eigenvalues and eigenfunctions for a flat turbine blade with small flexural stiffness.
Helmet-Mounted Display Of Clouds Of Harmful Gases
NASA Technical Reports Server (NTRS)
Diner, Daniel B.; Barengoltz, Jack B.; Schober, Wayne R.
1995-01-01
Proposed helmet-mounted opto-electronic instrument provides real-time stereoscopic views of clouds of otherwise invisible toxic, explosive, and/or corrosive gas. Display semitransparent: images of clouds superimposed on scene ordinarily visible to wearer. Images give indications on sizes and concentrations of gas clouds and their locations in relation to other objects in scene. Instruments serve as safety devices for astronauts, emergency response crews, fire fighters, people cleaning up chemical spills, or anyone working near invisible hazardous gases. Similar instruments used as sensors in automated emergency response systems that activate safety equipment and emergency procedures. Both helmet-mounted and automated-sensor versions used at industrial sites, chemical plants, or anywhere dangerous and invisible or difficult-to-see gases present. In addition to helmet-mounted and automated-sensor versions, there could be hand-held version. In some industrial applications, desirable to mount instruments and use them similarly to parking-lot surveillance cameras.
NASA Technical Reports Server (NTRS)
Coulam, C. M.; Dunnette, W. H.; Wood, E. H.
1970-01-01
Two methods whereby a digital computer may be used to regulate a scintiscanning process are discussed from the viewpoint of computer input-output software. The computer's function, in this case, is to govern the data acquisition and storage, and to display the results to the investigator in a meaningful manner, both during and subsequent to the scanning process. Several methods (such as three-dimensional maps, contour plots, and wall-reflection maps) have been developed by means of which the computer can graphically display the data on-line, for real-time monitoring purposes, during the scanning procedure and subsequently for detailed analysis of the data obtained. A computer-governed method for converting scintiscan data recorded over the dorsal or ventral surfaces of the thorax into fractions of pulmonary blood flow traversing the right and left lungs is presented.
Testing the accuracy of timing reports in visual timing tasks with a consumer-grade digital camera.
Smyth, Rachael E; Oram Cardy, Janis; Purcell, David
2017-06-01
This study tested the accuracy of a visual timing task using a readily available and relatively inexpensive consumer grade digital camera. A visual inspection time task was recorded using short high-speed video clips and the timing as reported by the task's program was compared to the timing as recorded in the video clips. Discrepancies in these two timing reports were investigated further and based on display refresh rate, a decision was made whether the discrepancy was large enough to affect the results as reported by the task. In this particular study, the errors in timing were not large enough to impact the results of the study. The procedure presented in this article offers an alternative method for performing a timing test, which uses readily available hardware and can be used to test the timing in any software program on any operating system and display.
Panoramic, large-screen, 3-D flight display system design
NASA Technical Reports Server (NTRS)
Franklin, Henry; Larson, Brent; Johnson, Michael; Droessler, Justin; Reinhart, William F.
1995-01-01
The report documents and summarizes the results of the required evaluations specified in the SOW and the design specifications for the selected display system hardware. Also included are the proposed development plan and schedule as well as the estimated rough order of magnitude (ROM) cost to design, fabricate, and demonstrate a flyable prototype research flight display system. The thrust of the effort was development of a complete understanding of the user/system requirements for a panoramic, collimated, 3-D flyable avionic display system and the translation of the requirements into an acceptable system design for fabrication and demonstration of a prototype display in the early 1997 time frame. Eleven display system design concepts were presented to NASA LaRC during the program, one of which was down-selected to a preferred display system concept. A set of preliminary display requirements was formulated. The state of the art in image source technology, 3-D methods, collimation methods, and interaction methods for a panoramic, 3-D flight display system were reviewed in depth and evaluated. Display technology improvements and risk reductions associated with maturity of the technologies for the preferred display system design concept were identified.
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. (a) Electronic display..., considering the expected electronic display brightness level at the end of an electronic display indictor's...
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. (a) Electronic display..., considering the expected electronic display brightness level at the end of an electronic display indictor's...
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. (a) Electronic display..., considering the expected electronic display brightness level at the end of an electronic display indictor's...
NASA Astrophysics Data System (ADS)
Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai
2013-12-01
In this paper, the laser speckle pattern on human retina for a laser projection display is simulated. By introducing a specific eye model `Indiana Eye', the statistical properties of the laser speckle are numerical investigated. The results show that the aberrations of human eye (mostly spherical and chromatic) will decrease the speckle contrast felt by people. When the wavelength of the laser source is 550 nm (green), people will feel the strongest speck pattern and the weakest when the wavelength is 450 nm (blue). Myopia and hyperopia will decrease the speckle contrast by introducing large spherical aberrations. Although aberration is good for speckle reduction, but it will degrade the imaging capability of the eye. The results show that laser source (650 nm) will have the best image quality on the retina. At last, we compare the human eye with an aberration-free imaging system. Both the speckle contrast and the image quality appear different behavior in these two imaging systems. The results are useful when a standardized measurement procedure for speckle contrast needs to be built.
Orion Underway Recovery Test 5 (URT-5) Trip - "52 Weeks of Scien
2016-10-19
Students visit the displays at the Logan Heights Library in San Diego, California, during the “52 Weeks of Science” celebration. The Ground Systems Development and Operations (GSDO) Program is participating in the special event with a Journey to Mars display before the start of Underway Recovery Test 5 using a test version of the Orion spacecraft in the Pacific Ocean off the coast of California. The test will allow NASA, Orion manufacturer Lockheed Martin and the U.S. Navy to demonstrate and evaluate the recovery processes, procedures, hardware and personnel necessary for recovery of the Orion crew module on its return from a deep space mission. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch atop NASA’s Space Launch System rocket in 2018. For more information, visit http://www.nasa.gov/orion.
Orion Underway Recovery Test 5 (URT-5) Trip - "52 Weeks of Scien
2016-10-19
A young student visits the displays at the Logan Heights Library in San Diego, California, during the “52 Weeks of Science” celebration. The Ground Systems Development and Operations (GSDO) Program is participating in the special event with a Journey to Mars display before the start of Underway Recovery Test 5 using a test version of the Orion spacecraft in the Pacific Ocean off the coast of California. The test will allow NASA, Orion manufacturer Lockheed Martin and the U.S. Navy to demonstrate and evaluate the recovery processes, procedures, hardware and personnel necessary for recovery of the Orion crew module on its return from a deep space mission. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch atop NASA’s Space Launch System rocket in 2018. For more information, visit http://www.nasa.gov/orion.
Orion Underway Recovery Test 5 (URT-5) Trip - "52 Weeks of Scien
2016-10-19
Students and parents visit the displays at the Logan Heights Library in San Diego, California, during the “52 Weeks of Science” celebration. The Ground Systems Development and Operations (GSDO) Program is participating in the special event with a Journey to Mars display before the start of Underway Recovery Test 5 using a test version of the Orion spacecraft in the Pacific Ocean off the coast of California. The test will allow NASA, Orion manufacturer Lockheed Martin and the U.S. Navy to demonstrate and evaluate the recovery processes, procedures, hardware and personnel necessary for recovery of the Orion crew module on its return from a deep space mission. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch atop NASA’s Space Launch System rocket in 2018. For more information, visit http://www.nasa.gov/orion.
2014-05-10
CAPE CANAVERAL, Fla. – Doug Lenhardt, Kennedy Space Center's Exploration Flight Test-1, or EFT-1, mission integration manager displays a baseball from the San Diego Padres inside Petco Park in San Diego, California. NASA's Orion boilerplate test vehicle is on display at the stadium. The boilerplate test vehicle is being prepared for an EFT-1 pre-transportation test. The Ground Systems Development and Operations Program will run the test to simulate retrieval and transportation procedures for Orion after it splashes down in the ocean and is retrieved for return to land and ground transportation back to Kennedy Space Center in Florida. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of the Orion is scheduled to launch later this year atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
Measurement of urinary calcium using AT89C51RD2 microcontroller.
Neelamegam, P; Jamaludeen, A; Rajendran, A; Raghunathan, R
2009-04-01
A simple and inexpensive absorption technique for determination of calcium ion in urine samples is developed, comprising a light emitting diode (650 nm) as the light source and photodiode as the detector with AT89C51RD2 microcontroller. The design of the system and details of interface, calibration, and procedure of operation are explained in this paper. Software is developed to monitor sample processing and to display the results in liquid crystal display screen. With 15 microl sample volume, a linear output is obtained in the range of 2.5-7.5 mM calcium with a detection limit of 0.06 mM. Interferences from other cations such as monovalent ion and divalent ion are investigated in the expected range, which are normally present in clinical samples, and absorption changes over the pH range of 3-12 are also determined. This system has been demonstrated successfully for the successive assay of calcium in urine samples, with the results comparing well to those achieved and in good agreement with values obtained with the current clinical spectrophotometric method at 95% of confidence level.
Advanced Transport Operating System (ATOPS) color displays software description: MicroVAX system
NASA Technical Reports Server (NTRS)
Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.
1992-01-01
This document describes the software created for the Display MicroVAX computer used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery of February 27, 1991, known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global references section includes subroutines, functions, and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight Cathode Ray Tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.
Segmental intelligibility of synthetic speech produced by rule.
Logan, J S; Greene, B G; Pisoni, D B
1989-08-01
This paper reports the results of an investigation that employed the modified rhyme test (MRT) to measure the segmental intelligibility of synthetic speech generated automatically by rule. Synthetic speech produced by ten text-to-speech systems was studied and compared to natural speech. A variation of the standard MRT was also used to study the effects of response set size on perceptual confusions. Results indicated that the segmental intelligibility scores formed a continuum. Several systems displayed very high levels of performance that were close to or equal to scores obtained with natural speech; other systems displayed substantially worse performance compared to natural speech. The overall performance of the best system, DECtalk--Paul, was equivalent to the data obtained with natural speech for consonants in syllable-initial position. The findings from this study are discussed in terms of the use of a set of standardized procedures for measuring intelligibility of synthetic speech under controlled laboratory conditions. Recent work investigating the perception of synthetic speech under more severe conditions in which greater demands are made on the listener's processing resources is also considered. The wide range of intelligibility scores obtained in the present study demonstrates important differences in perception and suggests that not all synthetic speech is perceptually equivalent to the listener.
Segmental intelligibility of synthetic speech produced by rule
Logan, John S.; Greene, Beth G.; Pisoni, David B.
2012-01-01
This paper reports the results of an investigation that employed the modified rhyme test (MRT) to measure the segmental intelligibility of synthetic speech generated automatically by rule. Synthetic speech produced by ten text-to-speech systems was studied and compared to natural speech. A variation of the standard MRT was also used to study the effects of response set size on perceptual confusions. Results indicated that the segmental intelligibility scores formed a continuum. Several systems displayed very high levels of performance that were close to or equal to scores obtained with natural speech; other systems displayed substantially worse performance compared to natural speech. The overall performance of the best system, DECtalk—Paul, was equivalent to the data obtained with natural speech for consonants in syllable-initial position. The findings from this study are discussed in terms of the use of a set of standardized procedures for measuring intelligibility of synthetic speech under controlled laboratory conditions. Recent work investigating the perception of synthetic speech under more severe conditions in which greater demands are made on the listener’s processing resources is also considered. The wide range of intelligibility scores obtained in the present study demonstrates important differences in perception and suggests that not all synthetic speech is perceptually equivalent to the listener. PMID:2527884
Inattentional blindness increased with augmented reality surgical navigation.
Dixon, Benjamin J; Daly, Michael J; Chan, Harley H L; Vescan, Allan; Witterick, Ian J; Irish, Jonathan C
2014-01-01
Augmented reality (AR) surgical navigation systems, designed to increase accuracy and efficiency, have been shown to negatively impact on attention. We wished to assess the effect "head-up" AR displays have on attention, efficiency, and accuracy, while performing a surgical task, compared with the same information being presented on a submonitor (SM). Fifty experienced otolaryngology surgeons (n = 42) and senior otolaryngology trainees (n = 8) performed an endoscopic surgical navigation exercise on a predissected cadaveric model. Computed tomography-generated anatomic contours were fused with the endoscopic image to provide an AR view. Subjects were randomized to perform the task with a standard endoscopic monitor with the AR navigation displayed on an SM or with AR as a single display. Accuracy, task completion time, and the recognition of unexpected findings (a foreign body and a critical complication) were recorded. Recognition of the foreign body was significantly better in the SM group (15/25 [60%]) compared with the AR alone group (8/25 [32%]; p = 0.02). There was no significant difference in task completion time (p = 0.83) or accuracy (p = 0.78) between the two groups. Providing identical surgical navigation on a SM, rather than on a single head-up display, reduced the level of inattentional blindness as measured by detection of unexpected findings. These gains were achieved without any measurable impact on efficiency or accuracy. AR displays may distract the user and we caution injudicious adoption of this technology for medical procedures.
Yoshimitsu, Kitaro; Suzuki, Takashi; Muragaki, Yoshihiro; Chernov, Mikhail; Iseki, Hiroshi
2010-01-01
Gliomas represent the most frequent type of primary intracranial tumors, which originate from the brain tissue itself, have infiltrative growth, unclear borders, and usually affect functionally-important cerebral structures. From March 2000 till March 2010, 839 neurosurgical procedures directed on resection of such neoplasms were performed in the intelligent operating theater of Tokyo Women's Medical University with the use of intraoperative MRI, real-time updated neuronavigation system, and Hi-vision operative microscope. To facilitate maximal possible tumor resection with minimal risk of neurological morbidity a special device, called Intraoperative Examination Monitor for Awake Surgery (IEMAS) was developed by us. It provides an opportunity to visualize a wide spectrum of inraoperative information related to condition of the patient, nuances of the surgical procedure, and details of the cortical mapping. The wide set of both anatomical and functional parameters, such as view of the patient's mimic and face movements during answering on the specific questions, type of examination test, position of the surgical instruments, parameters of the bispectral index monitor, and general view of the surgical field through the operating microscope and/or endoscope, is presented compactly in one screen with several displays, which allows fast integrated real-time analysis of the multiple data, nearly without interruption of the surgical manipulations. All members of the surgical team can share this information using several in-room liquid crystal displays. However, the initially designed IEMAS system was occasionally affected by interruption or detachment of the connecting cables, which could interfere with effective advancement of the surgical procedure. To avoid this problem a modified device was created. Its specific feature is wireless information transmitting function attained by incorporation of transmitters with a frequency range of 2.4 GHz. The clinical testing of t- - his system was initiated on February 1, 2010, but quickly revealed crossed line effect between transmitters and receivers. To overcome this obstacle and to isolate transmitters, one channel was changed from wireless connection into wired, which resulted in significant improvement of the clearness of both transmitted images and sounds, and provides an opportunity for effective clinical use of the device. In perspective we wish to make IEMAS system fully wireless, using several types of frequency range transmitters.
Video display engineering and optimization system
NASA Technical Reports Server (NTRS)
Larimer, James (Inventor)
1997-01-01
A video display engineering and optimization CAD simulation system for designing a LCD display integrates models of a display device circuit, electro-optics, surface geometry, and physiological optics to model the system performance of a display. This CAD system permits system performance and design trade-offs to be evaluated without constructing a physical prototype of the device. The systems includes a series of modules which permit analysis of design trade-offs in terms of their visual impact on a viewer looking at a display.
Designing a wearable navigation system for image-guided cancer resection surgery
Shao, Pengfei; Ding, Houzhu; Wang, Jinkun; Liu, Peng; Ling, Qiang; Chen, Jiayu; Xu, Junbin; Zhang, Shiwu; Xu, Ronald
2015-01-01
A wearable surgical navigation system is developed for intraoperative imaging of surgical margin in cancer resection surgery. The system consists of an excitation light source, a monochromatic CCD camera, a host computer, and a wearable headset unit in either of the following two modes: head-mounted display (HMD) and Google glass. In the HMD mode, a CMOS camera is installed on a personal cinema system to capture the surgical scene in real-time and transmit the image to the host computer through a USB port. In the Google glass mode, a wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A software program is written in Python to call OpenCV functions for image calibration, co-registration, fusion, and display with augmented reality. The imaging performance of the surgical navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex vivo tissue model. Surgical margins identified by the wearable navigation system are co-incident with those acquired by a standard small animal imaging system, indicating the technical feasibility for intraoperative surgical margin detection. The proposed surgical navigation system combines the sensitivity and specificity of a fluorescence imaging system and the mobility of a wearable goggle. It can be potentially used by a surgeon to identify the residual tumor foci and reduce the risk of recurrent diseases without interfering with the regular resection procedure. PMID:24980159
Designing a wearable navigation system for image-guided cancer resection surgery.
Shao, Pengfei; Ding, Houzhu; Wang, Jinkun; Liu, Peng; Ling, Qiang; Chen, Jiayu; Xu, Junbin; Zhang, Shiwu; Xu, Ronald
2014-11-01
A wearable surgical navigation system is developed for intraoperative imaging of surgical margin in cancer resection surgery. The system consists of an excitation light source, a monochromatic CCD camera, a host computer, and a wearable headset unit in either of the following two modes: head-mounted display (HMD) and Google glass. In the HMD mode, a CMOS camera is installed on a personal cinema system to capture the surgical scene in real-time and transmit the image to the host computer through a USB port. In the Google glass mode, a wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A software program is written in Python to call OpenCV functions for image calibration, co-registration, fusion, and display with augmented reality. The imaging performance of the surgical navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex vivo tissue model. Surgical margins identified by the wearable navigation system are co-incident with those acquired by a standard small animal imaging system, indicating the technical feasibility for intraoperative surgical margin detection. The proposed surgical navigation system combines the sensitivity and specificity of a fluorescence imaging system and the mobility of a wearable goggle. It can be potentially used by a surgeon to identify the residual tumor foci and reduce the risk of recurrent diseases without interfering with the regular resection procedure.
Apollo experience report: Real-time display system
NASA Technical Reports Server (NTRS)
Sullivan, C. J.; Burbank, L. W.
1976-01-01
The real time display system used in the Apollo Program is described; the systematic organization of the system, which resulted from hardware/software trade-offs and the establishment of system criteria, is emphasized. Each basic requirement of the real time display system was met by a separate subsystem. The computer input multiplexer subsystem, the plotting display subsystem, the digital display subsystem, and the digital television subsystem are described. Also described are the automated display design and the generation of precision photographic reference slides required for the three display subsystems.
NASA Technical Reports Server (NTRS)
Baxley, B.; Williams, D.; Consiglio, M.; Conway, S.; Adams, C.; Abbott, T.
2005-01-01
The ability to conduct concurrent, multiple aircraft operations in poor weather, at virtually any airport, offers an important opportunity for a significant increase in the rate of flight operations, a major improvement in passenger convenience, and the potential to foster growth of charter operations at small airports. The Small Aircraft Transportation System, (SATS) Higher Volume Operations (HVO) concept is designed to increase traffic flow at any of the 3400 nonradar, non-towered airports in the United States where operations are currently restricted to one-in/one-out procedural separation during Instrument Meteorological Conditions (IMC). The concept's key feature is pilots maintain their own separation from other aircraft using procedures, aircraft flight data sent via air-to-air datalink, cockpit displays, and on-board software. This is done within the Self-Controlled Area (SCA), an area of flight operations established during poor visibility or low ceilings around an airport without Air Traffic Control (ATC) services. The research described in this paper expands the HVO concept to include most off-nominal situations that could be expected to occur in a future SATS environment. The situations were categorized into routine off-nominal operations, procedural deviations, equipment malfunctions, and aircraft emergencies. The combination of normal and off-nominal HVO procedures provides evidence for an operational concept that is safe, requires little ground infrastructure, and enables concurrent flight operations in poor weather.
NASA Astrophysics Data System (ADS)
Galadí-Enríquez, D.
2018-02-01
Correlated color temperature (CCT) is a semi-quantitative system that roughly describes the spectra of lamps. This parameter gives the temperature (measured in kelvins) of the black body that would show the hue more similar to that of the light emitted by the lamp. Modern lamps for indoor and outdoor lighting display many spectral energy distributions, most of them extremely different to those of black bodies, what makes CCT to be far from a perfect descriptor from the physical point of view. The spectral index system presented in this work provides an accurate, objective, quantitative procedure to characterize the spectral properties of lamps, with just a few numbers. The system is an adaptation to lighting technology of the classical procedures of multi-band astronomical photometry with wide and intermediate-band filters. We describe the basic concepts and we apply the system to a representative set of lamps of many kinds. The results lead to interesting, sometimes surprising conclusions. The spectral index system is extremely easy to implement from the spectral data that are routinely measured at laboratories. Thus, including this kind of computations in the standard protocols for the certification of lamps will be really straightforward, and will enrich the technical description of lighting devices.
Development and evaluation of an instrumented linkage system for total knee surgery.
Walker, Peter S; Wei, Chih-Shing; Forman, Rachel E; Balicki, M A
2007-10-01
The principles and application of total knee surgery using optical tracking have been well demonstrated, but electromagnetic tracking may offer further advantages. We asked whether an instrumented linkage that attaches directly to the bone can maintain the accuracy of the optical and electromagnetic systems but be quicker, more convenient, and less expensive to use. Initial testing using a table-mounted digitizer to navigate a drill guide for placing pins to mount a cutting guide demonstrated the feasibility in terms of access and availability. A first version (called the Mark 1) instrumented linkage designed to fix directly to the bone was constructed and software was written to carry out a complete total knee replacement procedure. The results showed the system largely fulfilled these goals, but some surgeons found that using a visual display for pin placement was difficult and time consuming. As a result, a second version of a linkage system (called the K-Link) was designed to further develop the concept. User-friendly flexible software was developed for facilitating each step quickly and accurately while the placement of cutting guides was facilitated. We concluded that an instrumented linkage system could be a useful and potentially lower-cost option to the current systems for total knee replacement and could possibly have application to other surgical procedures.
2015-01-01
1 3.0 Methods, Assumptions, and Procedures ...18 4.6.3. LineUp Web... Procedures A search of the internet looking at web sites specializing in graphics, graphics engines, web browser applications, and games was conducted to
NASA Technical Reports Server (NTRS)
1975-01-01
Flow charts and display formats for the simulation of five experiments are given. The experiments are: (1) electromagnetic wave transmission; (2) passive observations of ambient plasma; (3) ionospheric measurements with subsatellite; (4) electron accelerator beam measurements; and (5) measurement of acoustical gravity waves in the sodium layer using lasers. A detailed explanation of the simulation procedure, definition of variables, and an explanation of how the experimenter makes display choices is also presented. A functional description is included on each flow chart and the assumptions and definitions of terms and scope of the flow charts and displays are presented.
Selection dynamic of Escherichia coli host in M13 combinatorial peptide phage display libraries.
Zanconato, Stefano; Minervini, Giovanni; Poli, Irene; De Lucrezia, Davide
2011-01-01
Phage display relies on an iterative cycle of selection and amplification of random combinatorial libraries to enrich the initial population of those peptides that satisfy a priori chosen criteria. The effectiveness of any phage display protocol depends directly on library amino acid sequence diversity and the strength of the selection procedure. In this study we monitored the dynamics of the selective pressure exerted by the host organism on a random peptide library in the absence of any additional selection pressure. The results indicate that sequence censorship exerted by Escherichia coli dramatically reduces library diversity and can significantly impair phage display effectiveness.
NASA Technical Reports Server (NTRS)
Fales, Janine L.
1991-01-01
The capabilities of the postprocessing program CANDI (Color Animation of Nastran DIsplacements) were expanded to accept results from axisymmetric analysis. An auxiliary program, ANIMATE, was developed to allow color display of CANDI output on the IRIS 4D-series workstations. The user can interactively manipulate the graphics display by three-dimensional rotations, translations, and scaling through the use of the keyboard and/or dials box. The user can also specify what portion of the model is displayed. These developments are limited to the display of complex displacements calculated with the NASHUA/NASTRAN procedure for structural acoustics analysis.
NASA Astrophysics Data System (ADS)
Apollonio, F. I.; Baldissini, S.; Clini, P.; Gaiani, M.; Palestini, C.; Trevisan, C.
2013-07-01
The paper describes objectives, methods, procedures and outcomes of the development of the digital archive of Palladio works and documentation: the PALLADIOLibrary of Centro Internazionale di Studi di Architettura Andrea Palladio di Vicenza (CISAAP). The core of the application consists of fifty-one reality-based 3D models usable and navigable within a system grounded on GoogleEarth. This information system, a collaboration of four universities bearers of specific skills returns a comprehensive, structured and coherent semantic interpretation of Palladian landscape through shapes realistically reconstructed from historical sources and surveys and treated for GE with Ambient Occlusion techniques, overcoming the traditional display mode.
NASA Turbulence Technologies In-Service Evaluation: Delta Air Lines Report-Out
NASA Technical Reports Server (NTRS)
Amaral, Christian; Dickson, Steve; Watts, Bill
2007-01-01
Concluding an in-service evaluation of two new turbulence detection technologies developed in the Turbulence Prediction and Warning Systems (TPAWS) element of the NASA Aviation Safety and Security Program's Weather Accident Prevention Project (WxAP), this report documents Delta's experience working with the technologies, feedback gained from pilots and dispatchers concerning current turbulence techniques and procedures, and Delta's recommendations regarding directions for further efforts by the research community. Technologies evaluated included an automatic airborne turbulence encounter reporting technology called the Turbulence Auto PIREP System (TAPS), and a significant enhancement to the ability of modern airborne weather radars to predict and display turbulence of operational significance, called E-Turb radar.
Effect of protein properties on display efficiency using the M13 phage display system.
Imai, S; Mukai, Y; Takeda, T; Abe, Y; Nagano, K; Kamada, H; Nakagawa, S; Tsunoda, S; Tsutsumi, Y
2008-10-01
The M13 phage display system is a powerful technology for engineering proteins such as functional mutant proteins and peptides. In this system, it is necessary that the protein is displayed on the phage surface. Therefore, its application is often limited when a protein is poorly displayed. In this study, we attempted to understand the relationship between a protein's properties and its display efficiency using the well-known pIII and pVIII type phage display system. The display of positively charged SV40 NLS and HIV-1 Tat peptides on pill was less efficient than that of the neutrally charged RGDS peptide. When different molecular weight proteins (1.5-58 kDa) were displayed on pIII and pVIII, their display efficiencies were directly influenced by their molecular weights. These results indicate the usefulness in predicting a desired protein's compatibility with protein and peptide engineering using the phage display system.
Measurements of striae in CR+ doped YAG laser crystals
NASA Astrophysics Data System (ADS)
Cady, Fredrick M.
1994-12-01
Striations in Czochralski (CZ) grown crystals have been observed in materials such as GaAs, silicon, photorefractive crystals used for data storage, potassium titanyl phosphate crystals and LiNbO3. Several techniques have been used for investigating these defects including electron microscopy, laser scanning tomography, selective photoetching, X-ray diffuse scattering, interference orthoscopy, laser interferometry and micro-Fourier transform infrared spectroscopy mapping. A 2mm thick sample of the material to be investigated is illuminated with light that is absorbed and non-absorbed by the ion concentration to be observed. The back surface of the sample is focused onto a solid-state image detector and images of the input beam and absorbed (and diffracted) beams are captured at two wavelengths. The variation of the coefficient of absorption asa function of distance on the sample can be derived from these measurements. A Big Sky Software Beamcode system is used to capture and display images. Software has been written to convert the Beamcode data files to a format that can be imported into a spreadsheet program such as Quatro Pro. The spreadsheet is then used to manipulate and display data. A model of the intensity map of the striae collected by the imaging system has been proposed and a data analysis procedure derived. From this, the variability of the attenuation coefficient alpha can be generated. Preliminary results show that alpha may vary by a factor of four or five over distances of 100 mu m. Potential errors and problems have been discovered and additional experiments and improvements to the experimental setup are in progress and we must now show that the measurement techniques and data analysis procedures provide 'real' information. Striae are clearly visible at all wavelengths including white light. Their basic spatial frequency does not change radically, at least when changing from blue to green to white light. Further experimental and theoretical work can be done to improve the data collection techniques and to verify the data analysis procedures.
A function-based approach to cockpit procedure aids
NASA Technical Reports Server (NTRS)
Phatak, Anil V.; Jain, Parveen; Palmer, Everett
1990-01-01
The objective of this research is to develop and test a cockpit procedural aid that can compose and present procedures that are appropriate for the given flight situation. The procedure would indicate the status of the aircraft engineering systems, and the environmental conditions. Prescribed procedures already exist for normal as well as for a number of non-normal and emergency situations, and can be presented to the crew using an interactive cockpit display. However, no procedures are prescribed or recommended for a host of plausible flight situations involving multiple malfunctions compounded by adverse environmental conditions. Under these circumstances, the cockpit procedural aid must review the prescribed procedures for the individual malfunction (when available), evaluate the alternatives or options, and present one or more composite procedures (prioritized or unprioritized) in response to the given situation. A top-down function-based conceptual approach towards composing and presenting cockpit procedures is being investigated. This approach is based upon the thought process that an operating crew must go through while attempting to meet the flight objectives given the current flight situation. In order to accomplish the flight objectives, certain critical functions must be maintained during each phase of the flight, using the appropriate procedures or success paths. The viability of these procedures depends upon the availability of required resources. If resources available are not sufficient to meet the requirements, alternative procedures (success paths) using the available resources must be constructed to maintain the critical functions and the corresponding objectives. If no success path exists that can satisfy the critical functions/objectives, then the next level of critical functions/objectives must be selected and the process repeated. Information is given in viewgraph form.
ORF phage display to identify cellular proteins with different functions.
Li, Wei
2012-09-01
Open reading frame (ORF) phage display is a new branch of phage display aimed at improving its efficiency to identify cellular proteins with specific binding or functional activities. Despite the success of phage display with antibody libraries and random peptide libraries, phage display with cDNA libraries of cellular proteins identifies a high percentage of non-ORF clones encoding unnatural short peptides with minimal biological implications. This is mainly because of the uncontrollable reading frames of cellular proteins in conventional cDNA libraries. ORF phage display solves this problem by eliminating non-ORF clones to generate ORF cDNA libraries. Here I summarize the procedures of ORF phage display, discuss the factors influencing its efficiency, present examples of its versatile applications, and highlight evidence of its capability of identifying biologically relevant cellular proteins. ORF phage display coupled with different selection strategies is capable of delineating diverse functions of cellular proteins with unique advantages. Copyright © 2012 Elsevier Inc. All rights reserved.
Advanced Caution and Warning System, Final Report - 2011
NASA Technical Reports Server (NTRS)
Spirkovska, Lilly; Aaseng, Gordon; Iverson, David; McCann, Robert S.; Robinson, Peter; Dittemore, Gary; Liolios, Sotirios; Baskaran, Vijay; Johnson, Jeremy; Lee, Charles;
2013-01-01
The work described in this report is a continuation of the ACAWS work funded in fiscal year (FY) 2010 under the Exploration Technology Development Program (ETDP), Integrated Systems Health Management (ISHM) project. In FY 2010, we developed requirements for an ACAWS system and vetted the requirements with potential users via a concept demonstration system. In FY 2011, we developed a working prototype of aspects of that concept, with placeholders for technologies to be fully developed in future phases of the project. The objective is to develop general capability to assist operators with system health monitoring and failure diagnosis. Moreover, ACAWS was integrated with the Discrete Controls (DC) task of the Autonomous Systems and Avionics (ASA) project. The primary objective of DC is to demonstrate an electronic and interactive procedure display environment and multiple levels of automation (automatic execution by computer, execution by computer if the operator consents, and manual execution by the operator).
NASA Astrophysics Data System (ADS)
Witkowski, Marcin; Lenar, Janusz; Sitnik, Robert; Verdonschot, Nico
2012-03-01
We present a human-computer interface that enables the operator to plan a surgical procedure on the musculoskeletal (MS) model of the patient's lower limbs, send the modified model to the bio-mechanical analysis module, and export the scenario parameters to the surgical navigation system. The interface provides the operator with tools for: importing customized MS model of the patient, cutting bones and manipulating/removal of bony fragments, repositioning muscle insertion points, muscle removal and placing implants. After planning the operator exports the modified MS model for bio-mechanical analysis of the functional outcome. If the simulation result is satisfactory the exported scenario data may be directly used during the actual surgery. The advantages of the developed interface are the possibility of installing it in various hardware configurations and coherent operation regardless of the devices used. The hardware configurations proposed to be used with the interface are: (a) a standard computer keyboard and mouse, and a 2-D display, (b) a touch screen as a single device for both input and output, or (c) a 3-D display and a haptic device for natural manipulation of 3-D objects. The interface may be utilized in two main fields. Experienced surgeons may use it to simulate their intervention plans and prepare input data for a surgical navigation system while student or novice surgeons can use it for simulating results of their hypothetical procedure. The interface has been developed in the TLEMsafe project (www.tlemsafe.eu) funded by the European Commission FP7 program.
Monocular display unit for 3D display with correct depth perception
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Hosomi, Takashi
2009-11-01
A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.
Jiang, Taoran; Zhu, Ming; Zan, Tao; Gu, Bin; Li, Qingfeng
2017-08-01
In perforator flap transplantation, dissection of the perforator is an important but difficult procedure because of the high variability in vascular anatomy. Preoperative imaging techniques could provide substantial information about vascular anatomy; however, it cannot provide direct guidance for surgeons during the operation. In this study, a navigation system (NS) was established to overlie a vascular map on surgical sites to further provide a direct guide for perforator flap transplantation. The NS was established based on computed tomographic angiography and augmented reality techniques. A virtual vascular map was reconstructed according to computed tomographic angiography data and projected onto real patient images using ARToolKit software. Additionally, a screw-fixation marker holder was created to facilitate registration. With the use of a tracking and display system, we conducted the NS on an animal model and measured the system error on a rapid prototyping model. The NS assistance allowed for correct identification, as well as a safe and precise dissection of the perforator. The mean value of the system error was determined to be 3.474 ± 1.546 mm. Augmented reality-based NS can provide precise navigation information by directly displaying a 3-dimensional individual anatomical virtual model onto the operative field in real time. It will allow rapid identification and safe dissection of a perforator in free flap transplantation surgery.
Interactive wire-frame ship hullform generation and display
NASA Technical Reports Server (NTRS)
Calkins, D. E.; Garbini, J. L.; Ishimaru, J.
1984-01-01
An interactive automated procedure to generate a wire frame graphic image of a ship hullform, which uses a digitizing tablet in conjunction with the hullform lines drawing, was developed. The geometric image created is displayed on an Evans & Sutherland PS-300 graphics terminal for real time interactive viewing or is output as hard copy on an inexpensive dot matrix printer.
Correction of gummy smile: A report of two cases
Narayan, Sarita; Narayan, T. V.; Jacob, P. C.
2011-01-01
Cosmetically acceptable smiles show a gingival display of up to 3 mm. Gingival display of greater than 3 mm results in a gummy smile which is often unsightly for the individual and correction is sought. There are a variety of procedures used for surgical crown lengthening. Here, we describe two such cases requiring two different approaches for surgical crown lengthening. PMID:22368373
Technical aspects of a demonstration tape for three-dimensional sound displays
NASA Technical Reports Server (NTRS)
Begault, Durand R.; Wenzel, Elizabeth M.
1990-01-01
This document was developed to accompany an audio cassette that demonstrates work in three-dimensional auditory displays, developed at the Ames Research Center Aerospace Human Factors Division. It provides a text version of the audio material, and covers the theoretical and technical issues of spatial auditory displays in greater depth than on the cassette. The technical procedures used in the production of the audio demonstration are documented, including the methods for simulating rotorcraft radio communication, synthesizing auditory icons, and using the Convolvotron, a real-time spatialization device.
Automated system function allocation and display format: Task information processing requirements
NASA Technical Reports Server (NTRS)
Czerwinski, Mary P.
1993-01-01
An important consideration when designing the interface to an intelligent system concerns function allocation between the system and the user. The display of information could be held constant, or 'fixed', leaving the user with the task of searching through all of the available information, integrating it, and classifying the data into a known system state. On the other hand, the system, based on its own intelligent diagnosis, could display only relevant information in order to reduce the user's search set. The user would still be left the task of perceiving and integrating the data and classifying it into the appropriate system state. Finally, the system could display the patterns of data. In this scenario, the task of integrating the data is carried out by the system, and the user's information processing load is reduced, leaving only the tasks of perception and classification of the patterns of data. Humans are especially adept at this form of display processing. Although others have examined the relative effectiveness of alphanumeric and graphical display formats, it is interesting to reexamine this issue together with the function allocation problem. Currently, Johnson Space Center is the test site for an intelligent Thermal Control System (TCS), TEXSYS, being tested for use with Space Station Freedom. Expert TCS engineers, as well as novices, were asked to classify several displays of TEXSYS data into various system states (including nominal and anomalous states). Three different display formats were used: fixed, subset, and graphical. The hypothesis tested was that the graphical displays would provide for fewer errors and faster classification times by both experts and novices, regardless of the kind of system state represented within the display. The subset displays were hypothesized to be the second most effective display format/function allocation condition, based on the fact that the search set is reduced in these displays. Both the subset and the graphic display conditions were hypothesized to be processed more efficiently than the fixed display conditions.
NASA Technical Reports Server (NTRS)
Axholt, Magnus; Skoglund, Martin; Peterson, Stephen D.; Cooper, Matthew D.; Schoen, Thomas B.; Gustafsson, Fredrik; Ynnerman, Anders; Ellis, Stephen R.
2010-01-01
Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.
Talamonti, Walter; Tijerina, Louis; Blommer, Mike; Swaminathan, Radhakrishnan; Curry, Reates; Ellis, R Darin
2017-11-01
This paper describes a new method, a 'mirage scenario,' to support formative evaluation of driver alerting or warning displays for manual and automated driving. This method provides driving contexts (e.g., various Times-To-Collision (TTCs) to a lead vehicle) briefly presented and then removed. In the present study, during each mirage event, a haptic steering display was evaluated. This haptic display indicated a steering response may be initiated to drive around an obstacle ahead. A motion-base simulator was used in a 32-participant study to present vehicle motion cues similar to the actual application. Surprise was neither present nor of concern, as it would be for a summative evaluation of a forward collision warning system. Furthermore, no collision avoidance maneuvers were performed, thereby reducing the risk of simulator sickness. This paper illustrates the mirage scenario procedures, the rating methods and definitions used with the mirage scenario, and analysis of the ratings obtained, together with a multi-attribute utility theory (MAUT) approach to evaluate and select among alternative designs for future summative evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.
A Procedure for the Computerized Analysis of Cleft Palate Speech Transcription
ERIC Educational Resources Information Center
Fitzsimons, David A.; Jones, David L.; Barton, Belinda; North, Kathryn N.
2012-01-01
The phonetic symbols used by speech-language pathologists to transcribe speech contain underlying hexadecimal values used by computers to correctly display and process transcription data. This study aimed to develop a procedure to utilise these values as the basis for subsequent computerized analysis of cleft palate speech. A computer keyboard…
A Pilot Study to Increase Chewing in Children with Feeding Disorders
ERIC Educational Resources Information Center
Volkert, Valerie M.; Piazza, Cathleen C.; Vaz, Petula C. M.; Frese, Jana
2013-01-01
Children with feeding disorders often display chewing deficits. Unfortunately, there is a paucity of research examining procedures to increase or teach chewing to children with feeding disorders. The few studies on this topic have utilized multicomponent treatments typically involving a shaping procedure. In addition, to our knowledge, studies on…
Displaying Special Characters and Symbols in Computer-Controlled Reaction Time Experiments.
ERIC Educational Resources Information Center
Friel, Brian M.; Kennison, Shelia M.
A procedure for using MEL2 (Version 2.0 of Microcomputer Experimental Laboratory) and FontWINDOW to present special characters and symbols in computer-controlled reaction time experiments is described. The procedure permits more convenience and flexibility than in tachistocopic and projection techniques. FontWINDOW allows researchers to design…
Aviation safety and automation technology for subsonic transports
NASA Technical Reports Server (NTRS)
Albers, James A.
1991-01-01
Discussed here are aviation safety human factors and air traffic control (ATC) automation research conducted at the NASA Ames Research Center. Research results are given in the areas of flight deck and ATC automations, displays and warning systems, crew coordination, and crew fatigue and jet lag. Accident investigation and an incident reporting system that is used to guide the human factors research is discussed. A design philosophy for human-centered automation is given, along with an evaluation of automation on advanced technology transports. Intelligent error tolerant systems such as electronic checklists are discussed along with design guidelines for reducing procedure errors. The data on evaluation of Crew Resource Management (CRM) training indicates highly significant positive changes in appropriate flight deck behavior and more effective use of available resources for crew members receiving the training.
Environmental Control System Development
NASA Technical Reports Server (NTRS)
Stewart, Raymond
2017-01-01
With the ever-growing desire for mankind to reach destinations whose distances had been deemed impossible to transit, the largest rocket known to man was designed and is being developed. The Space Launch System (SLS), National Aeronautics and Space Administration’s (NASA) solution for deep space travel, will begin its missions with the launch of Exploration Mission 1 (EM-1) and Exploration Mission 2 (EM-2). In order to accommodate the larger rocket, Kennedy Space Center made crucial upgrades to its existing facilities. At Launch Complex 39B, an entirely new Environmental Control System (ECS) was developed to supply the vehicle with the appropriate air or nitrogen gas mixture for launch. The new ECS displays must undergo Validation and Verification (V&V) using testing procedures developed to meet this requirement.
How children remember the Strange Situation: The role of attachment.
Chae, Yoojin; Goodman, Miranda; Goodman, Gail S; Troxel, Natalie; McWilliams, Kelly; Thompson, Ross A; Shaver, Phillip R; Widaman, Keith F
2018-02-01
This study tested predictions from Bowlby's attachment theory about children's memory and suggestibility. Young children (3-5years old, N=88; 76% Caucasians) and their parents took part in the Strange Situation Procedure, a moderately distressing event and "gold standard" for assessing children's attachment quality. The children were then interviewed about what occurred during the event. Children's age and attachment security scores positively predicted correct information in free recall and accuracy in answering specific questions. For children with higher (vs. lower) attachment security scores, greater distress observed during the Strange Situation Procedure predicted increased resistance to misleading suggestions. In addition, for children who displayed relatively low distress during the Strange Situation Procedure, significant age differences in memory and suggestibility emerged as expected. However, for children who displayed greater distress during the Strange Situation Procedure, younger and older children's memory performances were equivalent. Findings suggest that attachment theory provides an important framework for understanding facets of memory development with respect to attachment-related information and that distress may alter assumed age patterns in memory development. Copyright © 2017 Elsevier Inc. All rights reserved.
Tools virtualization for command and control systems
NASA Astrophysics Data System (ADS)
Piszczek, Marek; Maciejewski, Marcin; Pomianek, Mateusz; Szustakowski, Mieczysław
2017-10-01
Information management is an inseparable part of the command process. The result is that the person making decisions at the command post interacts with data providing devices in various ways. Tools virtualization process can introduce a number of significant modifications in the design of solutions for management and command. The general idea involves replacing physical devices user interface with their digital representation (so-called Virtual instruments). A more advanced level of the systems "digitalization" is to use the mixed reality environments. In solutions using Augmented reality (AR) customized HMI is displayed to the operator when he approaches to each device. Identification of device is done by image recognition of photo codes. Visualization is achieved by (optical) see-through head mounted display (HMD). Control can be done for example by means of a handheld touch panel. Using the immersive virtual environment, the command center can be digitally reconstructed. Workstation requires only VR system (HMD) and access to information network. Operator can interact with devices in such a way as it would perform in real world (for example with the virtual hands). Because of their procedures (an analysis of central vision, eye tracking) MR systems offers another useful feature of reducing requirements for system data throughput. Due to the fact that at the moment we focus on the single device. Experiments carried out using Moverio BT-200 and SteamVR systems and the results of experimental application testing clearly indicate the ability to create a fully functional information system with the use of mixed reality technology.
An Electronic Pressure Profile Display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPI) unit which interfaces with a host computer. The host computer collects the pressure data from the DPI unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
An electronic pressure profile display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPT) unit which interfaces with a host computer. The host computer collects the pressure data from the DPT unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
Display technologies: application for the discovery of drug and gene delivery agents
Sergeeva, Anna; Kolonin, Mikhail G.; Molldrem, Jeffrey J.; Pasqualini, Renata; Arap, Wadih
2007-01-01
Recognition of molecular diversity of cell surface proteomes in disease is essential for the development of targeted therapies. Progress in targeted therapeutics requires establishing effective approaches for high-throughput identification of agents specific for clinically relevant cell surface markers. Over the past decade, a number of platform strategies have been developed to screen polypeptide libraries for ligands targeting receptors selectively expressed in the context of various cell surface proteomes. Streamlined procedures for identification of ligand-receptor pairs that could serve as targets in disease diagnosis, profiling, imaging and therapy have relied on the display technologies, in which polypeptides with desired binding profiles can be serially selected, in a process called biopanning, based on their physical linkage with the encoding nucleic acid. These technologies include virus/phage display, cell display, ribosomal display, mRNA display and covalent DNA display (CDT), with phage display being by far the most utilized. The scope of this review is the recent advancements in the display technologies with a particular emphasis on molecular mapping of cell surface proteomes with peptide phage display. Prospective applications of targeted compounds derived from display libraries in the discovery of targeted drugs and gene therapy vectors are discussed. PMID:17123658
Optimal cooperative control synthesis of active displays
NASA Technical Reports Server (NTRS)
Garg, S.; Schmidt, D. K.
1985-01-01
A technique is developed that is intended to provide a systematic approach to synthesizing display augmentation for optimal manual control in complex, closed-loop tasks. A cooperative control synthesis technique, previously developed to design pilot-optimal control augmentation for the plant, is extended to incorporate the simultaneous design of performance enhancing displays. The technique utilizes an optimal control model of the man in the loop. It is applied to the design of a quickening control law for a display and a simple K/s(2) plant, and then to an F-15 type aircraft in a multi-channel task. Utilizing the closed loop modeling and analysis procedures, the results from the display design algorithm are evaluated and an analytical validation is performed. Experimental validation is recommended for future efforts.
A rule-based expert system for generating control displays at the Advanced Photon Source
NASA Astrophysics Data System (ADS)
Coulter, Karen J.
1994-12-01
The integration of a rule-based expert system for generating screen displays for controlling and monitoring instrumentation under the Experimental Physics and Industrial Control System (EPICS) is presented. The expert system is implemented using CLIPS, an expert system shell from the Software Technology Branch at Lyndon B. Johnson Space Center. The user selects the hardware input and output to be displayed and the expert system constructs a graphical control screen appropriate for the data. Such a system provides a method for implementing a common look and feel for displays created by several different users and reduces the amount of time required to create displays for new hardware configurations. Users are able to modify the displays as needed using the EPICS display editor tool.
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: Report of Task Group 192
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podder, Tarun K., E-mail: tarun.podder@uhhospitals.org; Beaulieu, Luc; Caldwell, Barrett
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the applications of this technology have been in the implantation of seeds in patients with early-stage prostate cancer. Nevertheless, the techniques apply to any clinical site where interstitial brachytherapy is appropriate. In consideration of the rapid developments in this area, the American Association of Physicistsmore » in Medicine (AAPM) commissioned Task Group 192 to review the state-of-the-art in the field of robotic interstitial brachytherapy. This is a joint Task Group with the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO). All developed and reported robotic brachytherapy systems were reviewed. Commissioning and quality assurance procedures for the safe and consistent use of these systems are also provided. Manual seed placement techniques with a rigid template have an estimated in vivo accuracy of 3–6 mm. In addition to the placement accuracy, factors such as tissue deformation, needle deviation, and edema may result in a delivered dose distribution that differs from the preimplant or intraoperative plan. However, real-time needle tracking and seed identification for dynamic updating of dosimetry may improve the quality of seed implantation. The AAPM and GEC-ESTRO recommend that robotic systems should demonstrate a spatial accuracy of seed placement ≤1.0 mm in a phantom. This recommendation is based on the current performance of existing robotic brachytherapy systems and propagation of uncertainties. During clinical commissioning, tests should be conducted to ensure that this level of accuracy is achieved. These tests should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot–clinician and robot–patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.« less
NASA Astrophysics Data System (ADS)
Eichenlaub, Jesse B.
1995-03-01
Mounting a lenticular lens in front of a flat panel display is a well known, inexpensive, and easy way to create an autostereoscopic system. Such a lens produces half resolution 3D images because half the pixels on the LCD are seen by the left eye and half by the right eye. This may be acceptable for graphics, but it makes full resolution text, as displayed by common software, nearly unreadable. Very fine alignment tolerances normally preclude the possibility of removing and replacing the lens in order to switch between 2D and 3D applications. Lenticular lens based displays are therefore limited to use as dedicated 3D devices. DTI has devised a technique which removes this limitation, allowing switching between full resolution 2D and half resolution 3D imaging modes. A second element, in the form of a concave lenticular lens array whose shape is exactly the negative of the first lens, is mounted on a hinge so that it can be swung down over the first lens array. When so positioned the two lenses cancel optically, allowing the user to see full resolution 2D for text or numerical applications. The two lenses, having complementary shapes, naturally tend to nestle together and snap into perfect alignment when pressed together--thus obviating any need for user operated alignment mechanisms. This system represents an ideal solution for laptop and notebook computer applications. It was devised to meet the stringent requirements of a laptop computer manufacturer including very compact size, very low cost, little impact on existing manufacturing or assembly procedures, and compatibility with existing full resolution 2D text- oriented software as well as 3D graphics. Similar requirements apply to high and electronic calculators, several models of which now use LCDs for the display of graphics.
Simulation System for Training in Laparoscopic Surgery
NASA Technical Reports Server (NTRS)
Basdogan, Cagatay; Ho, Chih-Hao
2003-01-01
A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.
NASA Technical Reports Server (NTRS)
Johnson, Walter W.; Lachter, Joel B.; Battiste, Vernol; Lim, Veranika; Brandt, Summer L.; Koteskey, Robert W.; Dao, Arik-Quang V.; Ligda, Sarah V.; Wu, Shu-Chieh
2011-01-01
A primary feature of the Next Generation Air Transportation System (NextGen) is trajectory based operations (TBO). Under TBO, aircraft flight plans are known to computer systems on the ground that aid in scheduling and separation. The Future Air Navigation System (FANS) was developed to support TBO, but relatively few aircraft in the US are FANSequipped. Thus, any near-term implementation must provide TBO procedures for non-FANS aircraft. Previous research has explored controller clearances, but any implementation must also provide procedures for aircraft requests. The work presented here aims to surface issues surrounding TBO communication procedures for non-FANS aircraft and for aircraft requesting deviations around weather. Three types of communication were explored: Voice, FANS, and ACARS,(Aircraft Communications Addressing and Reporting System). ACARS and FANS are datacom systems that differ in that FANS allows uplinked flight plans to be loaded into the Flight Management System (FMS), while ACARS delivers flight plans as text that must be entered manually via the Control Display Unit (CDU). Sixteen pilots (eight two-person flight decks) and four controllers participated in 32 20-minute scenarios that required the flight decks to navigate through convective weather as they approached their top of descents (TODs). Findings: The rate of non-conformance was higher than anticipated, with aircraft off path more than 20% of the time. Controllers did not differentiate between the ACARS and FANS datacom, and were mixed in their preference for Voice vs. datacom (ACARS and FANS). Pilots uniformly preferred Voice to datacom, particularly ACARS. Much of their dislike appears to result from the slow response times in the datacom conditions. As a result, participants frequently resorted to voice communication. These results imply that, before implementing TBO in environments where pilots make weather deviation requests, further research is needed to develop communication procedures that integrate voice and datacom.
Use of an engineering data management system in the analysis of Space Shuttle Orbiter tiles
NASA Technical Reports Server (NTRS)
Giles, G. L.; Vallas, M.
1981-01-01
This paper demonstrates the use of an engineering data management system to facilitate the extensive stress analyses of the Space Shuttle Orbiter thermal protection system. Descriptions are given of the approach and methods used (1) to gather, organize, and store the data, (2) to query data interactively, (3) to generate graphic displays of the data, and (4) to access, transform, and prepare the data for input to a stress analysis program. The relational information management system was found to be well suited to the tile analysis problem because information related to many separate tiles could be accessed individually from a data base having a natural organization from an engineering viewpoint. The flexible user features of the system facilitated changes in data content and organization which occurred during the development and refinement of the tile analysis procedure. Additionally, the query language supported retrieval of data to satisfy a variety of user-specified conditions.
Usability engineering: domain analysis activities for augmented-reality systems
NASA Astrophysics Data System (ADS)
Gabbard, Joseph; Swan, J. E., II; Hix, Deborah; Lanzagorta, Marco O.; Livingston, Mark; Brown, Dennis B.; Julier, Simon J.
2002-05-01
This paper discusses our usability engineering process for the Battlefield Augmented Reality System (BARS). Usability engineering is a structured, iterative, stepwise development process. Like the related disciplines of software and systems engineering, usability engineering is a combination of management principals and techniques, formal and semi- formal evaluation techniques, and computerized tools. BARS is an outdoor augmented reality system that displays heads- up battlefield intelligence information to a dismounted warrior. The paper discusses our general usability engineering process. We originally developed the process in the context of virtual reality applications, but in this work we are adapting the procedures to an augmented reality system. The focus of this paper is our work on domain analysis, the first activity of the usability engineering process. We describe our plans for and our progress to date on our domain analysis for BARS. We give results in terms of a specific urban battlefield use case we have designed.
Development of Land Analysis System display modules
NASA Technical Reports Server (NTRS)
Gordon, Douglas; Hollaren, Douglas; Huewe, Laurie
1986-01-01
The Land Analysis System (LAS) display modules were developed to allow a user to interactively display, manipulate, and store image and image related data. To help accomplish this task, these modules utilize the Transportable Applications Executive and the Display Management System software to interact with the user and the display device. The basic characteristics of a display are outlined and some of the major modifications and additions made to the display management software are discussed. Finally, all available LAS display modules are listed along with a short description of each.
Color Helmet-Mounted Display System for In-Flight Simulation on the RASCAL Research Helicopter
NASA Technical Reports Server (NTRS)
Edwards, Tim; Barnhart, Warren; Sawyer, Kevin; Aiken, Edwin W. (Technical Monitor)
1995-01-01
A high performance color helmet mounted display (HMD) system for in-flight simulation and research has been developed for the Rotorcraft Aircrew Systems Concepts Laboratory (RASCAL). The display system consists of a programmable display generator, a display electronics unit, a head tracker, and the helmet with display optics. The system provides a maximum of 1024 x 1280 resolution, a 4:1 contrast ratio, and a brightness of 1100fL utilizing currently available technologies. This paper describes the major features and components of the system. Also discussed are the measured performance of the system and the design techniques that allowed the development of a full color HMD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, D; MacDougall, R
2016-06-15
Purpose: Accurate values for Kerma-Area-Product (KAP) are needed for patient dosimetry and quality control for exams utilizing radiographic and/or fluoroscopic imaging. The KAP measured using a typical direct KAP meter built with parallel-plate transmission ionization chamber is not precise and depends on the energy spectrum of diagnostic x-rays. This study compared the accuracy and reproducibility of KAP derived from system parameters with values measured with a direct KAP meter. Methods: IEC tolerance for displayed KAP is specified up to ± 35% above 2.5 Gy-cm{sup 2} and manufacturer’s specifications are typically ± 25%. KAP values from the direct KAP meter driftsmore » with time leading to replacement or re-calibration. More precise and consistent KAP is achievable utilizing a database of known radiation output for various system parameters. The integrated KAP meter was removed from a radiography system. A total of 48 measurements of air kerma were acquired at x-ray tube potential from 40 to 150 kVp with 10 kVp increment using ion chamber type external dosimeter at free-in-air geometry for four different types of filter combinations following the manufacturer’s service procedure. These data were used to create updated correction factors that determine air kerma computationally for given system parameters. Results of calculated KAP were evaluated against results using a calibrated ion chamber based dosimeter and a computed radiography imaging plate to measure x-ray field size. Results: The accuracy of calculated KAP from the system parameters was better within 4% deviation in all diagnostic x-ray tube potentials tested from 50 to 140 kVp. In contrast, deviations of up to 25% were measured from KAP displayed from the direct KAP meter. Conclusion: The “calculated KAP” approach provides the nominal advantage of improved accuracy and precision of displayed KAP as well as reduced cost of calibrating or replacing integrated KAP meters.« less
,
2004-01-01
The Ground-Water Site-Inventory (GWSI) System is a ground-water data storage and retrieval system that is part of the National Water Information System (NWIS) developed by the U.S. Geological Survey (USGS). The NWIS is a distributed water database in which data can be processed over a network of workstations and file servers at USGS offices throughout the United States. This system comprises the GWSI, the Automated Data Processing System (ADAPS), the Water-Quality System (QWDATA), and the Site-Specific Water-Use Data System (SWUDS). The GWSI System provides for entering new sites and updating existing sites within the local database. In addition, the GWSI provides for retrieving and displaying ground-water and sitefile data stored in the local database. Finally, the GWSI provides for routine maintenance of the local and national data records. This manual contains instructions for users of the GWSI and discusses the general operating procedures for the programs found within the GWSI Main Menu.
,
2005-01-01
The Ground-Water Site-Inventory (GWSI) System is a ground-water data storage and retrieval system that is part of the National Water Information System (NWIS) developed by the U.S. Geological Survey (USGS). The NWIS is a distributed water database in which data can be processed over a network of workstations and file servers at USGS offices throughout the United States. This system comprises the GWSI, the Automated Data Processing System (ADAPS), the Water-Quality System (QWDATA), and the Site- Specific Water-Use Data System (SWUDS). The GWSI System provides for entering new sites and updating existing sites within the local database. In addition, the GWSI provides for retrieving and displaying groundwater and Sitefile data stored in the local database. Finally, the GWSI provides for routine maintenance of the local and national data records. This manual contains instructions for users of the GWSI and discusses the general operating procedures for the programs found within the GWSI Main Menu.
Flexible, Photopatterned, Colloidal CdSe Semiconductor Nanocrystal Integrated Circuits
NASA Astrophysics Data System (ADS)
Stinner, F. Scott
As semiconductor manufacturing pushes towards smaller and faster transistors, a parallel goal exists to create transistors which are not nearly as small. These transistors are not intended to match the performance of traditional crystalline semiconductors; they are designed to be significantly lower in cost and manufactured using methods that can make them physically flexible for applications where form is more important than speed. One of the developing technologies for this application is semiconductor nanocrystals. We first explore methods to develop CdSe nanocrystal semiconducting "inks" into large-scale, high-speed integrated circuits. We demonstrate photopatterned transistors with mobilities of 10 cm2/Vs on Kapton substrates. We develop new methods for vertical interconnect access holes to demonstrate multi-device integrated circuits including inverting amplifiers with 7 kHz bandwidths, ring oscillators with <10 micros stage delays, and NAND and NOR logic gates. In order to produce higher performance and more consistent transistors, we develop a new hybrid procedure for processing the CdSe nanocrystals. This procedure produces transistors with repeatable performance exceeding 40 cm2/Vs when fabricated on silicon wafers and 16 cm 2/vs when fabricated as part of photopatterned integrated circuits on Kapton substrates. In order to demonstrate the full potential of these transistors, methods to create high-frequency oscillators were developed. These methods allow for transistors to operate at higher voltages as well as provide a means for wirebonding to the Kapton substrate, both of which are required for operating and probing high-frequency oscillators. Simulations of this system show the potential for operation at MHz frequencies. Demonstration of these transistors in this frequency range would open the door for development of CdSe integrated circuits for high-performance sensor, display, and audio applications. To develop further applications of electronics on flexible substrates, procedures are developed for the integration of polychromatic displays on polyethylene terephthalate (PET) substrates and a commercial near field communication (NFC) link. The device draws its power from the NFC transmitter common on smartphones and eliminates the need for a fixed battery. This allows for the mass deployment of flexible, interactive displays on product packaging.
Study to design and develop remote manipulator system. [computer simulation of human performance
NASA Technical Reports Server (NTRS)
Hill, J. W.; Mcgovern, D. E.; Sword, A. J.
1974-01-01
Modeling of human performance in remote manipulation tasks is reported by automated procedures using computers to analyze and count motions during a manipulation task. Performance is monitored by an on-line computer capable of measuring the joint angles of both master and slave and in some cases the trajectory and velocity of the hand itself. In this way the operator's strategies with different transmission delays, displays, tasks, and manipulators can be analyzed in detail for comparison. Some progress is described in obtaining a set of standard tasks and difficulty measures for evaluating manipulator performance.
Application of the Lucy–Richardson Deconvolution Procedure to High Resolution Photoemission Spectra
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rameau, J.; Yang, H.-B.; Johnson, P.D.
2010-07-01
Angle-resolved photoemission has developed into one of the leading probes of the electronic structure and associated dynamics of condensed matter systems. As with any experimental technique the ability to resolve features in the spectra is ultimately limited by the resolution of the instrumentation used in the measurement. Previously developed for sharpening astronomical images, the Lucy-Richardson deconvolution technique proves to be a useful tool for improving the photoemission spectra obtained in modern hemispherical electron spectrometers where the photoelectron spectrum is displayed as a 2D image in energy and momentum space.
Proceedings of the 8th Annual Conference on Manual Control
NASA Technical Reports Server (NTRS)
Pew, R. W.
1972-01-01
The volume presents recent developments in the field of manual control theory and applications. The papers give analytical methods as well as examples of the important interplay between man and machine, such as how man controls and stabilizes machine dynamics, and how machines extend man's capability. Included in the broad range of subjects are procedures to evaluate and identify display systems, controllers, manipulators, human operators, aircraft, and non-flying vehicles. Of particular interest is the continuing trend of applying control theory to problems in medicine and psychology, as well as to problems in vehicle control.
Concept of Operations for Commercial and Business Aircraft Synthetic Vision Systems. 1.0
NASA Technical Reports Server (NTRS)
Williams Daniel M.; Waller, Marvin C.; Koelling, John H.; Burdette, Daniel W.; Capron, William R.; Barry, John S.; Gifford, Richard B.; Doyle, Thomas M.
2001-01-01
A concept of operations (CONOPS) for the Commercial and Business (CaB) aircraft synthetic vision systems (SVS) is described. The CaB SVS is expected to provide increased safety and operational benefits in normal and low visibility conditions. Providing operational benefits will promote SVS implementation in the Net, improve aviation safety, and assist in meeting the national aviation safety goal. SVS will enhance safety and enable consistent gate-to-gate aircraft operations in normal and low visibility conditions. The goal for developing SVS is to support operational minima as low as Category 3b in a variety of environments. For departure and ground operations, the SVS goal is to enable operations with a runway visual range of 300 feet. The system is an integrated display concept that provides a virtual visual environment. The SVS virtual visual environment is composed of three components: an enhanced intuitive view of the flight environment, hazard and obstacle defection and display, and precision navigation guidance. The virtual visual environment will support enhanced operations procedures during all phases of flight - ground operations, departure, en route, and arrival. The applications selected for emphasis in this document include low visibility departures and arrivals including parallel runway operations, and low visibility airport surface operations. These particular applications were selected because of significant potential benefits afforded by SVS.
Quick-disconnect harness system for helmet-mounted displays
NASA Astrophysics Data System (ADS)
Bapu, P. T.; Aulds, M. J.; Fuchs, Steven P.; McCormick, David M.
1992-10-01
We have designed a pilot's harness-mounted, high voltage quick-disconnect connectors with 62 pins, to transmit voltages up to 13.5 kV and video signals with 70 MHz bandwidth, for a binocular helmet-mounted display system. It connects and disconnects with power off, and disconnects 'hot' without pilot intervention and without producing external sparks or exposing hot embers to the explosive cockpit environment. We have implemented a procedure in which the high voltage pins disconnect inside a hermetically-sealed unit before the physical separation of the connector. The 'hot' separation triggers a crowbar circuit in the high voltage power supplies for additional protection. Conductor locations and shields are designed to reduce capacitance in the circuit and avoid crosstalk among adjacent circuits. The quick- disconnect connector and wiring harness are human-engineered to ensure pilot safety and mobility. The connector backshell is equipped with two hybrid video amplifiers to improve the clarity of the video signals. Shielded wires and coaxial cables are molded as a multi-layered ribbon for maximum flexibility between the pilot's harness and helmet. Stiff cabling is provided between the quick-disconnect connector and the aircraft console to control behavior during seat ejection. The components of the system have been successfully tested for safety, performance, ergonomic considerations, and reliability.
CT imaging with a mobile C-arm prototype
NASA Astrophysics Data System (ADS)
Cheryauka, Arvi; Tubbs, David; Langille, Vinton; Kalya, Prabhanjana; Smith, Brady; Cherone, Rocco
2008-03-01
Mobile X-ray imagery is an omnipresent tool in conventional musculoskeletal and soft tissue applications. The next generation of mobile C-arm systems can provide clinicians of minimally-invasive surgery and pain management procedures with both real-time high-resolution fluoroscopy and intra-operative CT imaging modalities. In this study, we research two C-arm CT experimental system configurations and evaluate their imaging capabilities. In a non-destructive evaluation configuration, the X-ray Tube - Detector assembly is stationary while an imaging object is placed on a rotating table. In a medical imaging configuration, the C-arm gantry moves around the patient and the table. In our research setting, we connect the participating devices through a Mobile X-Ray Imaging Environment known as MOXIE. MOXIE is a set of software applications for internal research at GE Healthcare - Surgery and used to examine imaging performance of experimental systems. Anthropomorphic phantom volume renderings and orthogonal slices of reconstructed images are obtained and displayed. The experimental C-arm CT results show CT-like image quality that may be suitable for interventional procedures, real-time data management, and, therefore, have great potential for effective use on the clinical floor.
De Deyne, Cathy; Heylen, René
2004-01-01
Operating Room (OR) information systems should manage the OR time, assigned to every surgeon, thereby minimizing the sum of costs of unused OR time and minimizing the costs of elective cases performed outside normal allocated OR time (excess OR-time). The aim of this paper is to illustrate how the introduction of an OR information system influenced daily OR activity performance. Since January 2001, we introduced an OR information system with a visual, airport-like, screen as central part, displaying all scheduled OR activity linked in real-time activity with all OR theatres. For the aim of this paper, we compared all data of OR activity for elective abdominal surgery (EAS) for the first half of 2000 compared to the first half of 2001, after the introduction of our information system. In 2000, 764 elective cases were performed, compared to 815 cases in 2001. For both periods, the total OR time allocated to EAS for this 6 months period was 805 h. For 2000, the total duration of OR activity for EAS was 1044 h 50 min (implicating 239 h 50 min over-time), compared to 1127 h 35 min (implicating 322 h 35 min overtime) for 2001. For 2000, we recorded 147 h 20 min excess time (=exceeding the time limits of OR activity and inducing extra costs) and 46h45min unused OR time. For 2001, we recorded 123 h 04 min excess time and 35 h 21 min unused time. In conclusion, in 2001 we recorded an increase in total OR activity for elective abdominal surgery by 7% in number of procedures and by 8% in total duration. However, in 2001 we recorded a decrease in excess time by 16% (123 h 04 min vs 147 h 20 min), which was for a large part due to a 23% decrease in unused OR time in 2001 compared to 2000 (35 h 21min vs 46 h 45 min). Therefore, the introduction of an OR information system, with a real-time visual display of ongoing OR activity, resulted in a increased performance of OR activity, with more OR procedures performed despite less excess time and less extra costs.
Implementing Computer-Based Procedures: Thinking Outside the Paper Margins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oxstrand, Johanna; Bly, Aaron
In the past year there has been increased interest from the nuclear industry in adopting the use of electronic work packages and computer-based procedures (CBPs) in the field. The goal is to incorporate the use of technology in order to meet the Nuclear Promise requirements of reducing costs and improve efficiency and decrease human error rates of plant operations. Researchers, together with the nuclear industry, have been investigating the benefits an electronic work package system and specifically CBPs would have over current paper-based procedure practices. There are several classifications of CBPs ranging from a straight copy of the paper-based proceduremore » in PDF format to a more intelligent dynamic CBP. A CBP system offers a vast variety of improvements, such as context driven job aids, integrated human performance tools (e.g., placekeeping and correct component verification), and dynamic step presentation. The latter means that the CBP system could only display relevant steps based on operating mode, plant status, and the task at hand. The improvements can lead to reduction of the worker’s workload and human error by allowing the work to focus on the task at hand more. A team of human factors researchers at the Idaho National Laboratory studied and developed design concepts for CBPs for field workers between 2012 and 2016. The focus of the research was to present information in a procedure in a manner that leveraged the dynamic and computational capabilities of a handheld device allowing the worker to focus more on the task at hand than on the administrative processes currently applied when conducting work in the plant. As a part of the research the team identified type of work, instructions, and scenarios where the transition to a dynamic CBP system might not be as beneficial as it would for other types of work in the plant. In most cases the decision to use a dynamic CBP system and utilize the dynamic capabilities gained will be beneficial to the worker. However, tasks that are reliant on the skill of the craft or have a short set of instructions may not provide a way or even need to utilize all the advanced capabilities in a dynamic CBP system. Therefore, a hybrid CBP system that could handle all the classifications of a CBP would be the best solution to take advantage of all that a CBP system offers. The implementation of a CBP system does not automatically improve the quality of procedures. Utilities should look into why each procedure is written the way it currently is on paper. Utilities should take the time before implementation to review, standardize format and update current procedures. Implementation of a CBP system can be a time to break out of traditional procedure writing processes and create new processes and procedures that take advantage of the capabilities a CBP system. This paper will summarize the research on CBPs and provide suggestions to take into consideration when implementing a CBP system.« less
Need for evaluative methodologies in land use, regional resource and waste management planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croke, E. J.
The transfer of planning methodology from the research community to the practitioner very frequently takes the form of analytical and evaluative techniques and procedures. In the end, these become operational in the form of data acquisition, management and display systems, computational schemes that are codified in the form of manuals and handbooks, and computer simulation models. The complexity of the socioeconomic and physical processes that govern environmental resource and waste management have reinforced the need for computer assisted, scientifically sophisticated planning models that are fully operational, dependent on an attainable data base and accessible in terms of the resources normallymore » available to practitioners of regional resource management, waste management, and land use planning. A variety of models and procedures that attempt to meet one or more of the needs of these practitioners are discussed.« less
NASA Technical Reports Server (NTRS)
Lillesand, T. M.; Meisner, D. E. (Principal Investigator)
1980-01-01
An investigation was conducted into ways to improve the involvement of state and local user personnel in the digital image analysis process by isolating those elements of the analysis process which require extensive involvement by field personnel and providing means for performing those activities apart from a computer facility. In this way, the analysis procedure can be converted from a centralized activity focused on a computer facility to a distributed activity in which users can interact with the data at the field office level or in the field itself. A general image processing software was developed on the University of Minnesota computer system (Control Data Cyber models 172 and 74). The use of color hardcopy image data as a primary medium in supervised training procedures was investigated and digital display equipment and a coordinate digitizer were procured.
Global positioning system supported pilot's display
NASA Technical Reports Server (NTRS)
Scott, Marshall M., Jr.; Erdogan, Temel; Schwalb, Andrew P.; Curley, Charles H.
1991-01-01
The hardware, software, and operation of the Microwave Scanning Beam Landing System (MSBLS) Flight Inspection System Pilot's Display is discussed. The Pilot's Display is used in conjunction with flight inspection tests that certify the Microwave Scanning Beam Landing System used at Space Shuttle landing facilities throughout the world. The Pilot's Display was developed for the pilot of test aircraft to set up and fly a given test flight path determined by the flight inspection test engineers. This display also aids the aircraft pilot when hazy or cloud cover conditions exist that limit the pilot's visibility of the Shuttle runway during the flight inspection. The aircraft position is calculated using the Global Positioning System and displayed in the cockpit on a graphical display.
Optimal front light design for reflective displays under different ambient illumination
NASA Astrophysics Data System (ADS)
Wang, Sheng-Po; Chang, Ting-Ting; Li, Chien-Ju; Bai, Yi-Ho; Hu, Kuo-Jui
2011-01-01
The goal of this study is to find out the optimal luminance and color temperature of front light for reflective displays in different ambient illumination by conducting series of psychophysical experiments. A color and brightness tunable front light device with ten LED units was built and been calibrated to present 256 luminance levels and 13 different color temperature at fixed luminance of 200 cd/m2. The experiment results revealed the best luminance and color temperature settings for human observers under different ambient illuminant, which could also assist the e-paper manufacturers to design front light device, and present the best image quality on reflective displays. Furthermore, a similar experiment procedure was conducted by utilizing new flexible e-signage display developed by ITRI and an optimal front light device for the new display panel has been designed and utilized.
A flexible flight display research system using a ground-based interactive graphics terminal
NASA Technical Reports Server (NTRS)
Hatfield, J. J.; Elkins, H. C.; Batson, V. M.; Poole, W. L.
1975-01-01
Requirements and research areas for the air transportation system of the 1980 to 1990's were reviewed briefly to establish the need for a flexible flight display generation research tool. Specific display capabilities required by aeronautical researchers are listed and a conceptual system for providing these capabilities is described. The conceptual system uses a ground-based interactive graphics terminal driven by real-time radar and telemetry data to generate dynamic, experimental flight displays. These displays are scan converted to television format, processed, and transmitted to the cockpits of evaluation aircraft. The attendant advantages of a Flight Display Research System (FDRS) designed to employ this concept are presented. The detailed implementation of an FDRS is described. The basic characteristics of the interactive graphics terminal and supporting display electronic subsystems are presented and the resulting system capability is summarized. Finally, the system status and utilization are reviewed.
Cryotherapy simulator for localized prostate cancer.
Hahn, James K; Manyak, Michael J; Jin, Ge; Kim, Dongho; Rewcastle, John; Kim, Sunil; Walsh, Raymond J
2002-01-01
Cryotherapy is a treatment modality that uses a technique to selectively freeze tissue and thereby cause controlled tissue destruction. The procedure involves placement of multiple small diameter probes through the perineum into the prostate tissue at selected spatial intervals. Transrectal ultrasound is used to properly position the cylindrical probes before activation of the liquid Argon cooling element, which lowers the tissue temperature below -40 degrees Centigrade. Tissue effect is monitored by transrectal ultrasound changes as well as thermocouples placed in the tissue. The computer-based cryotherapy simulation system mimics the major surgical steps involved in the procedure. The simulated real-time ultrasound display is generated from 3-D ultrasound datasets where the interaction of the ultrasound with the instruments as well as the frozen tissue is simulated by image processing. The thermal and mechanical simulations of the tissue are done using a modified finite-difference/finite-element method optimized for real-time performance. The simulator developed is a part of a comprehensive training program, including a computer-based learning system and hands-on training program with a proctor, designed to familiarize the physician with the technique and equipment involved.
On-the-fly augmented reality for orthopedic surgery using a multimodal fiducial.
Andress, Sebastian; Johnson, Alex; Unberath, Mathias; Winkler, Alexander Felix; Yu, Kevin; Fotouhi, Javad; Weidert, Simon; Osgood, Greg; Navab, Nassir
2018-04-01
Fluoroscopic x-ray guidance is a cornerstone for percutaneous orthopedic surgical procedures. However, two-dimensional (2-D) observations of the three-dimensional (3-D) anatomy suffer from the effects of projective simplification. Consequently, many x-ray images from various orientations need to be acquired for the surgeon to accurately assess the spatial relations between the patient's anatomy and the surgical tools. We present an on-the-fly surgical support system that provides guidance using augmented reality and can be used in quasiunprepared operating rooms. The proposed system builds upon a multimodality marker and simultaneous localization and mapping technique to cocalibrate an optical see-through head mounted display to a C-arm fluoroscopy system. Then, annotations on the 2-D x-ray images can be rendered as virtual objects in 3-D providing surgical guidance. We quantitatively evaluate the components of the proposed system and, finally, design a feasibility study on a semianthropomorphic phantom. The accuracy of our system was comparable to the traditional image-guided technique while substantially reducing the number of acquired x-ray images as well as procedure time. Our promising results encourage further research on the interaction between virtual and real objects that we believe will directly benefit the proposed method. Further, we would like to explore the capabilities of our on-the-fly augmented reality support system in a larger study directed toward common orthopedic interventions.
NASA Technical Reports Server (NTRS)
Waller, Marvin C.; Scanlon, Charles H.
1999-01-01
A number of our nations airports depend on closely spaced parallel runway operations to handle their normal traffic throughput when weather conditions are favorable. For safety these operations are curtailed in Instrument Meteorological Conditions (IMC) when the ceiling or visibility deteriorates and operations in many cases are limited to the equivalent of a single runway. Where parallel runway spacing is less than 2500 feet, capacity loss in IMC is on the order of 50 percent for these runways. Clearly, these capacity losses result in landing delays, inconveniences to the public, increased operational cost to the airlines, and general interruption of commerce. This document presents a description and the results of a fixed-base simulation study to evaluate an initial concept that includes a set of procedures for conducting safe flight in closely spaced parallel runway operations in IMC. Consideration of flight-deck information technology and displays to support the procedures is also included in the discussions. The procedures and supporting technology rely heavily on airborne capabilities operating in conjunction with the air traffic control system.
Sayler, Elaine; Eldredge-Hindy, Harriet; Dinome, Jessie; Lockamy, Virginia; Harrison, Amy S
2015-01-01
The planning procedure for Valencia and Leipzig surface applicators (VLSAs) (Nucletron, Veenendaal, The Netherlands) differs substantially from CT-based planning; the unfamiliarity could lead to significant errors. This study applies failure modes and effects analysis (FMEA) to high-dose-rate (HDR) skin brachytherapy using VLSAs to ensure safety and quality. A multidisciplinary team created a protocol for HDR VLSA skin treatments and applied FMEA. Failure modes were identified and scored by severity, occurrence, and detectability. The clinical procedure was then revised to address high-scoring process nodes. Several key components were added to the protocol to minimize risk probability numbers. (1) Diagnosis, prescription, applicator selection, and setup are reviewed at weekly quality assurance rounds. Peer review reduces the likelihood of an inappropriate treatment regime. (2) A template for HDR skin treatments was established in the clinic's electronic medical record system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planner as well as increases the detectability of an error. (3) A screen check was implemented during the second check to increase detectability of an error. (4) To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display, facilitating data entry and verification. (5) VLSAs are color coded and labeled to match the electronic medical record prescriptions, simplifying in-room selection and verification. Multidisciplinary planning and FMEA increased detectability and reduced error probability during VLSA HDR brachytherapy. This clinical model may be useful to institutions implementing similar procedures. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Telementoring systems in the operating room: a new approach in medical training.
Wachs, Juan P; Gomez, Gerardo
2013-01-01
This paper discusses the challenges and innovations related to the use of telementoring systems in the operating room. Most of the systems presented leverage on three types of interaction channels: audio, visual and physical. The audio channel enables the mentor to verbally instruct the trainee, and allows the trainee to ask questions. The visual channel is used to deliver annotations, alerts and other messages graphically to the trainee during the surgery. These visual representations are often displayed through a telestrator. The physical channel has been used in laparoscopic procedures by partially controlling the laparoscope through force-feedback. While in face to face instruction, the mentor produces gestures to convey certain aspects of the surgical instruction, there is not equivalent of this form of physical interaction between the mentor and trainee in open surgical procedures in telementoring systems. Even that the trend is to perform more minimally invasive surgery (MIS), trauma surgeries are still necessary, where initial resuscitation and stabilization of the patient in a timely manner is crucial. This paper presents a preliminary study conducted at the Indiana University Medical School and Purdue University, where initial lexicons of surgical instructive gestures (SIGs) were determined through systematic observation when mentor and trainee operate together. The paper concludes with potential ways to convey gestural information through surgical robots.
COMPARING THE TEACHING INTERACTION PROCEDURE TO SOCIAL STORIES FOR PEOPLE WITH AUTISM
Leaf, Justin B; Oppenheim-Leaf, Misty L; Call, Nikki A; Sheldon, Jan B; Sherman, James A; Taubman, Mitchell; McEachin, John; Dayharsh, Jamison; Leaf, Ronald
2012-01-01
This study compared social stories and the teaching interaction procedure to teach social skills to 6 children and adolescents with an autism spectrum disorder. Researchers taught 18 social skills with social stories and 18 social skills with the teaching interaction procedure within a parallel treatment design. The teaching interaction procedure resulted in mastery of all 18 skills across the 6 participants. Social stories, in the same amount of teaching sessions, resulted in mastery of 4 of the 18 social skills across the 6 participants. Participants also displayed more generalization of social skills taught with the teaching interaction procedure to known adults and peers. PMID:22844137
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... Devices, Navigation and Display Systems, Radar Systems, Navigational Aids, Mapping Systems and Related... navigation products, including GPS devices, navigation and display systems, radar systems, navigational aids..., radar systems, navigational aids, mapping systems and related software by reason of infringement of one...
Technical aspects of telepathology with emphasis on future development.
Schwarzmann, P; Binder, B; Klose, R
2000-01-01
Pathology undergoes presently changes due to new developments in diagnostic opportunities and cost saving efforts in health care. Out of the wide field of telepathology the paper selects three prototype applications: telepathology in teleeducation, expert advice for preselected details of a slide and finally telepathology for remote diagnosis. The most challenging field for remote diagnosis is the application in the frozen section scenario. The paper starts with the mental experiment to map conventional procedures to counterparts in telepathology. Technical opportunities and economical restrictions of telepathology equipment are discussed with respect to the components: electronic camera, display devices, haptic sensors and displays, available telecommunication channels and telepathology software. As an example and for illustration of the state of the art for an advanced telemicroscopy system able to perform remote frozen section diagnosis, the HISTKOM equipment is presented in more details. The section concerning future developments regards the aspects of the acceptance by tentative users, legal aspects, costs and affordability of equipment, the market for equipment components and the adequate telecommunication services. Further is regarded the mutual influence of properties of existing systems and application experiences gained with them on the next generation of equipment and application software. Conclusions and references close the paper.
Onboard Short Term Plan Viewer
NASA Technical Reports Server (NTRS)
Hall, Tim; LeBlanc, Troy; Ulman, Brian; McDonald, Aaron; Gramm, Paul; Chang, Li-Min; Keerthi, Suman; Kivlovitz, Dov; Hadlock, Jason
2011-01-01
Onboard Short Term Plan Viewer (OSTPV) is a computer program for electronic display of mission plans and timelines, both aboard the International Space Station (ISS) and in ISS ground control stations located in several countries. OSTPV was specifically designed both (1) for use within the limited ISS computing environment and (2) to be compatible with computers used in ground control stations. OSTPV supplants a prior system in which, aboard the ISS, timelines were printed on paper and incorporated into files that also contained other paper documents. Hence, the introduction of OSTPV has both reduced the consumption of resources and saved time in updating plans and timelines. OSTPV accepts, as input, the mission timeline output of a legacy, print-oriented, UNIX-based program called "Consolidated Planning System" and converts the timeline information for display in an interactive, dynamic, Windows Web-based graphical user interface that is used by both the ISS crew and ground control teams in real time. OSTPV enables the ISS crew to electronically indicate execution of timeline steps, launch electronic procedures, and efficiently report to ground control teams on the statuses of ISS activities, all by use of laptop computers aboard the ISS.
Simulation Evaluation of Synthetic Vision as an Enabling Technology for Equivalent Visual Operations
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Williams, Steven P.; Bailey, Randall E.
2008-01-01
Enhanced Vision (EV) and synthetic vision (SV) systems may serve as enabling technologies to meet the challenges of the Next Generation Air Transportation System (NextGen) Equivalent Visual Operations (EVO) concept ? that is, the ability to achieve or even improve on the safety of Visual Flight Rules (VFR) operations, maintain the operational tempos of VFR, and even, perhaps, retain VFR procedures independent of actual weather and visibility conditions. One significant challenge lies in the definition of required equipage on the aircraft and on the airport to enable the EVO concept objective. A piloted simulation experiment was conducted to evaluate the effects of the presence or absence of Synthetic Vision, the location of this information during an instrument approach (i.e., on a Head-Up or Head-Down Primary Flight Display), and the type of airport lighting information on landing minima. The quantitative data from this experiment were analyzed to begin the definition of performance-based criteria for all-weather approach and landing operations. Objective results from the present study showed that better approach performance was attainable with the head-up display (HUD) compared to the head-down display (HDD). A slight performance improvement in HDD performance was shown when SV was added, as the pilots descended below 200 ft to a 100 ft decision altitude, but this performance was not tested for statistical significance (nor was it expected to be statistically significant). The touchdown data showed that regardless of the display concept flown (SV HUD, Baseline HUD, SV HDD, Baseline HDD) a majority of the runs were within the performance-based defined approach and landing criteria in all the visibility levels, approach lighting systems, and decision altitudes tested. For this visual flight maneuver, RVR appeared to be the most significant influence in touchdown performance. The approach lighting system clearly impacted the pilot's ability to descend to 100 ft height above touchdown based on existing Federal Aviation Regulation (FAR) 91.175 using a 200 ft decision height, but did not appear to influence touchdown performance or approach path maintenance
Apollo experience report: Crew station integration. Volume 2: Crew station displays and controls
NASA Technical Reports Server (NTRS)
Langdoc, W. A.; Nassman, D. A.
1975-01-01
The functional requirements for the Apollo displays and controls system are presented. The configuration of the displays, controls, and panels for both the command module and the lunar module are described, and the design development and operational experience of the displays and controls system are discussed. Pertinent recommendations for future displays and controls system design efforts are made.
NASA Technical Reports Server (NTRS)
Wiegman, E. J.; Evans, W. E.; Hadfield, R.
1975-01-01
Measurements are examined of snow coverage during the snow-melt season in 1973 and 1974 from LANDSAT imagery for the three Columbia River Subbasins. Satellite derived snow cover inventories for the three test basins were obtained as an alternative to inventories performed with the current operational practice of using small aircraft flights over selected snow fields. The accuracy and precision versus cost for several different interactive image analysis procedures was investigated using a display device, the Electronic Satellite Image Analysis Console. Single-band radiance thresholding was the principal technique employed in the snow detection, although this technique was supplemented by an editing procedure involving reference to hand-generated elevation contours. For each data and view measured, a binary thematic map or "mask" depicting the snow cover was generated by a combination of objective and subjective procedures. Photographs of data analysis equipment (displays) are shown.
NASA Spinoff Article: Automated Procedures To Improve Safety on Oil Rigs
NASA Technical Reports Server (NTRS)
Garud, Sumedha
2013-01-01
On May 11th, 2013, two astronauts emerged from the interior of the International Space Station (ISS) and worked their way toward the far end of spacecraft. Over the next 51/2 hours, the two replaced an ammonia pump that had developed a significant leak a few days before. On the ISS, ammonia serves the vital role of cooling components-in this case, one of the station's eight solar arrays. Throughout the extravehicular activity (EVA), the astronauts stayed in constant contact with mission control: every movement, every action strictly followed a carefully planned set of procedures to maximize crew safety and the chances of success. Though the leak had come as a surprise, NASA was prepared to handle it swiftly thanks in part to the thousands of procedures that have been written to cover every aspect of the ISS's operations. The ISS is not unique in this regard: Every NASA mission requires well-written procedures-or detailed lists of step-by-step instructions-that cover how to operate equipment in any scenario, from normal operations to the challenges created by malfunctioning hardware or software. Astronauts and mission control train and drill extensively in procedures to ensure they know what the proper procedures are and when they should be used. These procedures used to be exclusively written on paper, but over the past decade, NASA has transitioned to digital formats. Electronic-based documentation simplifies storage and use, allowing astronauts and flight controllers to find instructions more quickly and display them through a variety of media. Electronic procedures are also a crucial step toward automation: once instructions are digital, procedure display software can be designed to assist in authoring, reviewing, and even executing them.
Behavioral analysis of children's response to induction of anesthesia.
Chorney, Jill MacLaren; Kain, Zeev N
2009-11-01
It is documented that children experience distress at anesthesia induction, but little is known about the prevalence of specific behaviors exhibited by children. Digital audiovisual recordings of 293 children undergoing outpatient elective surgery were coded using Observer XT software and the validated Revised Perioperative Child-Adult Medical Procedure Interaction Scale. Multiple pass second-by-second data recording was used to capture children's behaviors across phases of anesthesia induction. More than 40% of children aged 2-10 yr displayed some distress behavior during induction with 17% of these children displaying significant distress and more than 30% of children resisting anesthesiologists during induction. Children's distress and nondistress behaviors displayed four profiles over the course of anesthesia induction: Acute Distress, Anticipatory Distress, Early Regulating Behaviors, and Engagement with Procedure. Older children had higher scores on early regulating and engagement profiles whereas younger children had higher scores on Acute Distress. There were no differences across age in children's Anticipatory Distress. Construct validity of behavior profiles was supported via correlations of profile score (overall and on the walk to the operating room) with a validated assessment of children's anxiety at induction. Children undergoing anesthesia display a range of distress and nondistress behaviors. A group of behaviors was identified that, when displayed on the walk to the operating room, is associated with less distress at anesthesia induction. These data provide the first examination of potentially regulating behaviors of children, but more detailed sequential analysis is required to validate specific functions of these behaviors.
Scaling theory of topological phase transitions
NASA Astrophysics Data System (ADS)
Chen, Wei
2016-02-01
Topologically ordered systems are characterized by topological invariants that are often calculated from the momentum space integration of a certain function that represents the curvature of the many-body state. The curvature function may be Berry curvature, Berry connection, or other quantities depending on the system. Akin to stretching a messy string to reveal the number of knots it contains, a scaling procedure is proposed for the curvature function in inversion symmetric systems, from which the topological phase transition can be identified from the flow of the driving energy parameters that control the topology (hopping, chemical potential, etc) under scaling. At an infinitesimal operation, one obtains the renormalization group (RG) equations for the driving energy parameters. A length scale defined from the curvature function near the gap-closing momentum is suggested to characterize the scale invariance at critical points and fixed points, and displays a universal critical behavior in a variety of systems examined.
Effectiveness of an Expert System for Astronaut Assistance on a Sleep Experiment
NASA Technical Reports Server (NTRS)
Heher, Dennis; Callini, Gianluca; Essig, Susanne M.; Young, Laurence R.; Koga, Dennis (Technical Monitor)
1998-01-01
Principal Investigator-in-a-Box ([PI]) is an expert system designed to train and assist astronauts with the performance of an experiment outside their field of expertise, particularly when contact with the Principal Investigators on the ground is limited or impossible. In the current case, [PI] was designed to assist with the calibration and troubleshooting procedures of the Neurolab Sleep and Respiration Experiment during the pre-sleep period of no ground contact. It displays physiological signals in real time during the pre-sleep instrumentation period, and alerts the astronauts when a poor signal quality is detected. Results of the first study indicated a beneficial effect of [PI] and training in reducing anomaly detection time and the number of undetected anomalies. For the in-flight performance, excluding the saturated signals, the expert system had an 84.2% detection accuracy, and the questionnaires filled out by the astronauts showed positive crew reactions to the expert system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murav’ev, V. P., E-mail: murval@mail.ru; Kochetkov, A. V.; Glazova, E. G.
An algorithm and software for calculating the optimal operating regimes of the process water supply system at the Kalininskaya NPP are described. The parameters of the optimal regimes are determined for time varying meteorological conditions and condensation loads of the NPP. The optimal flow of the cooling water in the turbines is determined computationally; a regime map with the data on the optimal water consumption distribution between the coolers and displaying the regimes with an admissible heat load on the natural cooling lakes is composed. Optimizing the cooling system for a 4000-MW NPP will make it possible to conserve atmore » least 155,000 MW · h of electricity per year. The procedure developed can be used to optimize the process water supply systems of nuclear and thermal power plants.« less
Atlas-based system for functional neurosurgery
NASA Astrophysics Data System (ADS)
Nowinski, Wieslaw L.; Yeo, Tseng T.; Yang, Guo L.; Dow, Douglas E.
1997-05-01
This paper addresses the development of an atlas-based system for preoperative functional neurosurgery planning and training, intraoperative support and postoperative analysis. The system is based on Atlas of Stereotaxy of the Human Brain by Schaltenbrand and Wahren used for interactive segmentation and labeling of clinical data in 2D/3D, and for assisting stereotactic targeting. The atlas microseries are digitized, enhanced, segmented, labeled, aligned and organized into mutually preregistered atlas volumes 3D models of the structures are also constructed. The atlas may be interactively registered with the actual patient's data. Several other features are also provided including data reformatting, visualization, navigation, mensuration, and stereotactic path display and editing in 2D/3D. The system increases the accuracy of target definition, reduces the time of planning and time of the procedure itself. It also constitutes a research platform for the construction of more advanced neurosurgery supporting tools and brain atlases.
50 CFR 15.21 - General application procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... purposes only: Scientific research; zoological breeding or display programs; cooperative breeding programs...: Office of Management Authority), 4401 N. Fairfax Drive, Room 700, Arlington, VA 22203. Each application...
50 CFR 15.21 - General application procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... purposes only: Scientific research; zoological breeding or display programs; cooperative breeding programs...: Office of Management Authority), 4401 N. Fairfax Drive, Room 700, Arlington, VA 22203. Each application...
Standardized access, display, and retrieval of medical video
NASA Astrophysics Data System (ADS)
Bellaire, Gunter; Steines, Daniel; Graschew, Georgi; Thiel, Andreas; Bernarding, Johannes; Tolxdorff, Thomas; Schlag, Peter M.
1999-05-01
The system presented here enhances documentation and data- secured, second-opinion facilities by integrating video sequences into DICOM 3.0. We present an implementation for a medical video server extended by a DICOM interface. Security mechanisms conforming with DICOM are integrated to enable secure internet access. Digital video documents of diagnostic and therapeutic procedures should be examined regarding the clip length and size necessary for second opinion and manageable with today's hardware. Image sources relevant for this paper include 3D laparoscope, 3D surgical microscope, 3D open surgery camera, synthetic video, and monoscopic endoscopes, etc. The global DICOM video concept and three special workplaces of distinct applications are described. Additionally, an approach is presented to analyze the motion of the endoscopic camera for future automatic video-cutting. Digital stereoscopic video sequences are especially in demand for surgery . Therefore DSVS are also integrated into the DICOM video concept. Results are presented describing the suitability of stereoscopic display techniques for the operating room.
NASA Johnson Space Center Usability Testing and Analysis Facility (UTAF) Overview
NASA Technical Reports Server (NTRS)
Whitmore, M.
2004-01-01
The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility provides support to the Office of Biological and Physical Research, the Space Shuttle Program, the International Space Station Program, and other NASA organizations. In addition, there are ongoing collaborative research efforts with external businesses and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes. This presentation will provide an overview of ongoing activities, and will address how the projects will evolve to meet new space initiatives.
NASA Johnson Space Center Usability Testing and Analysis Facility (WAF) Overview
NASA Technical Reports Server (NTRS)
Whitmore, M.
2004-01-01
The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility provides support to the Office of Biological and Physical Research, the Space Shuttle Program, the International Space Station Program, and other NASA organizations. In addition, there are ongoing collaborative research efforts with external businesses and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes. This presentation will provide an overview of ongoing activities, and will address how the projects will evolve to meet new space initiatives.
Interpersonal distance regulates functional grouping tendencies of agents in team sports.
Passos, Pedro; Milho, João; Fonseca, Sofia; Borges, João; Araújo, Duarte; Davids, Keith
2011-01-01
The authors examined whether, similar to collective agent behaviors in complex, biological systems (e.g., schools of fish and colonies of ants), performers in team sports displayed functional coordination tendencies, based on local interaction rules during performance. To investigate this issue, they used videogrammetry and digitizing procedures to observe interpersonal interactions in common 4 versus 2 + 2 subphases of the team sport of rugby union, involving 16 participants aged between 16 and 17 years of age. They observed pattern-forming dynamics in attacking subunits (n = 4 players) attempting to penetrate 2 defensive lines (n = 2 players in each). Data showed that within each attacking subunit, the 4 players displayed emergent functional grouping tendencies that differed between the 2 defensive lines. Results confirmed that grouping tendencies in attacking subunits of team games are sensitive to different task constraints, such as relative positioning to nearest defenders. It was concluded that running correlations were particularly useful for measuring the level of interpersonal coordination in functional grouping tendencies within attacking subunits.
The Multiple Doppler Radar Workshop, November 1979.
NASA Astrophysics Data System (ADS)
Carbone, R. E.; Harris, F. I.; Hildebrand, P. H.; Kropfli, R. A.; Miller, L. J.; Moninger, W.; Strauch, R. G.; Doviak, R. J.; Johnson, K. W.; Nelson, S. P.; Ray, P. S.; Gilet, M.
1980-10-01
The findings of the Multiple Doppler Radar Workshop are summarized by a series of six papers. Part I of this series briefly reviews the history of multiple Doppler experimentation, fundamental concepts of Doppler signal theory, and organization and objectives of the Workshop. Invited presentations by dynamicists and cloud physicists are also summarized.Experimental design and procedures (Part II) are shown to be of critical importance. Well-defined and limited experimental objectives are necessary in view of technological limitations. Specified radar scanning procedures that balance temporal and spatial resolution considerations are discussed in detail. Improved siting for suppression of ground clutter as well as scanning procedures to minimize errors at echo boundaries are discussed. The need for accelerated research using numerically simulated proxy data sets is emphasized.New technology to eliminate various sampling limitations is cited as an eventual solution to many current problems in Part III. Ground clutter contamination may be curtailed by means of full spectral processing, digital filters in real time, and/or variable pulse repetition frequency. Range and velocity ambiguities also may be minimized by various pulsing options as well as random phase transmission. Sidelobe contamination can be reduced through improvements in radomes, illumination patterns, and antenna feed types. Radar volume-scan time can be sharply reduced by means of wideband transmission, phased array antennas, multiple beam antennas, and frequency agility.Part IV deals with synthesis of data from several radars in the context of scientific requirements in cumulus clouds, widespread precipitation, and severe convective storms. The important temporal and spatial scales are examined together with the accuracy required for vertical air motion in each phenomenon. Factors that introduce errors in the vertical velocity field are identified and synthesis techniques are discussed separately for the dual Doppler and multiple Doppler cases. Various filters and techniques, including statistical and variational approaches, are mentioned. Emphasis is placed on the importance of experiment design and procedures, technological improvements, incorporation of all information from supporting sensors, and analysis priority for physically simple cases. Integrated reliability is proposed as an objective tool for radar siting.Verification of multiple Doppler-derived vertical velocity is discussed in Part V. Three categories of verification are defined as direct, deductive, and theoretical/numerical. Direct verification consists of zenith-pointing radar measurements (from either airborne or ground-based systems), air motion sensing aircraft, instrumented towers, and tracking of radar chaff. Deductive sources include mesonetworks, aircraft (thermodynamic and microphysical) measurements, satellite observations, radar reflectivity, multiple Doppler consistency, and atmospheric soundings. Theoretical/numerical sources of verification include proxy data simulation, momentum checking, and numerical cloud models. New technology, principally in the form of wide bandwidth radars, is seen as a development that may reduce the need for extensive verification of multiple Doppler-derived vertical air motions. Airborne Doppler radar is perceived as the single most important source of verification within the bounds of existing technology.Nine stages of data processing and display are identified in Part VI. The stages are identified as field checks, archival, selection, editing, coordinate transformation, synthesis of Cartesian fields, filtering, display, and physical analysis. Display of data is considered to be a problem critical to assimilation of data at all stages. Interactive computing systems and software are concluded to be very important, particularly for the editing stage. Three- and 4-dimensional displays are considered essential for data assimilation, particularly at the physical analysis stage. The concept of common data tape formats is approved both for data in radar spherical space as well as for synthesized Cartesian output.1169
Security Police Career Ladders AFSCs 811X0, 811X2, and 811X2A.
1984-11-01
MONITORS (GRP658) PERCENT MEMBERS PERFORMING TASKS (N=186) J424 PERFORM SPCDS OPERATOR REACTIONS TO SENSOR ALARM, LINE FAULT, OR UNIQUE LINE FAULT...MESSAGES 96 J426 PERFORM SPCDS VERIFICATION PROCEDURES 96 J423 PERFORM SMALL PERMANENT COMMUNICATIONS DISPLAY SEGMENT ( SPCDS ) SHUT-DOWN PROCEDURES 92 J425...PERFORM SPCDS START-UP PROCEDURES 91 J419 PERFORM BISS OPERATOR REACTION TO PRIME POWER LOSS OR SEVERE WEATHER WARNINGS 91 E192 MAKE ENTRIES ON AF
Design and Testing of a Low Noise Flight Guidance Concept
NASA Technical Reports Server (NTRS)
Williams, David H.; Oseguera-Lohr, Rosa M.; Lewis, Elliot T.
2004-01-01
A flight guidance concept was developed to assist in flying continuous descent approach (CDA) procedures designed to lower the noise under the flight path of jet transport aircraft during arrival operations at an airport. The guidance consists of a trajectory prediction algorithm that was tuned to produce a high-efficiency, low noise flight profile with accompanying autopilot and flight display elements needed by the flight control system and pilot to fly the approach. A key component of the flight guidance was a real-time display of energy error relative to the predicted flight path. The guidance was integrated with the conventional Flight Management System (FMS) guidance of a modern jet transport airplane and tested in a high fidelity flight simulation. A charted arrival procedure, which allowed flying conventional arrivals, CDA arrivals with standard guidance, and CDA arrivals with the new low noise guidance, was developed to assist in the testing and evaluation of the low noise guidance concept. Results of the simulation testing showed the low noise guidance was easy to use by airline pilot test subjects and effective in achieving the desired noise reduction. Noise under the flight path was reduced by at least 2 decibels in Sound Exposure Level (SEL) at distances from about 3 nautical miles out to about 17.5 nautical miles from the runway, with a peak reduction of 8.5 decibels at about 10.5 nautical miles. Fuel consumption was also reduced by about 17% for the LNG conditions compared to baseline runs for the same flight distance. Pilot acceptance and understanding of the guidance was quite high with favorable comments and ratings received from all test subjects.
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. Link to an amendment published at 76 FR 75760, December 2, 2011. (a) Electronic display indicators, including those with features...
Latency Requirements for Head-Worn Display S/EVS Applications
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Trey Arthur, J. J., III; Williams, Steven P.
2004-01-01
NASA s Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas flight control, flight simulation, and virtual reality are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.
Latency requirements for head-worn display S/EVS applications
NASA Astrophysics Data System (ADS)
Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.
2004-08-01
NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.
NASA Technical Reports Server (NTRS)
Mckee, James W.
1990-01-01
This volume (4 of 4) contains the description, structured flow charts, prints of the graphical displays, and source code to generate the displays for the AMPS graphical status system. The function of these displays is to present to the manager of the AMPS system a graphical status display with the hot boxes that allow the manager to get more detailed status on selected portions of the AMPS system. The development of the graphical displays is divided into two processes; the creation of the screen images and storage of them in files on the computer, and the running of the status program which uses the screen images.
Construction of High-Quality Camel Immune Antibody Libraries.
Romão, Ema; Poignavent, Vianney; Vincke, Cécile; Ritzenthaler, Christophe; Muyldermans, Serge; Monsion, Baptiste
2018-01-01
Single-domain antibodies libraries of heavy-chain only immunoglobulins from camelids or shark are enriched for high-affinity antigen-specific binders by a short in vivo immunization. Thus, potent binders are readily retrieved from relatively small-sized libraries of 10 7 -10 8 individual transformants, mostly after phage display and panning on a purified target. However, the remaining drawback of this strategy arises from the need to generate a dedicated library, for nearly every envisaged target. Therefore, all the procedures that shorten and facilitate the construction of an immune library of best possible quality are definitely a step forward. In this chapter, we provide the protocol to generate a high-quality immune VHH library using the Golden Gate Cloning strategy employing an adapted phage display vector where a lethal ccdB gene has to be substituted by the VHH gene. With this procedure, the construction of the library can be shortened to less than a week starting from bleeding the animal. Our libraries exceed 10 8 individual transformants and close to 100% of the clones harbor a phage display vector having an insert with the length of a VHH gene. These libraries are also more economic to make than previous standard approaches using classical restriction enzymes and ligations. The quality of the Nanobodies that are retrieved from immune libraries obtained by Golden Gate Cloning is identical to those from immune libraries made according to the classical procedure.
Structured grid technology to enable flow simulation in an integrated system environment
NASA Astrophysics Data System (ADS)
Remotigue, Michael Gerard
An application-driven Computational Fluid Dynamics (CFD) environment needs flexible and general tools to effectively solve complex problems in a timely manner. In addition, reusable, portable, and maintainable specialized libraries will aid in rapidly developing integrated systems or procedures. The presented structured grid technology enables the flow simulation for complex geometries by addressing grid generation, grid decomposition/solver setup, solution, and interpretation. Grid generation is accomplished with the graphical, arbitrarily-connected, multi-block structured grid generation software system (GUM-B) developed and presented here. GUM-B is an integrated system comprised of specialized libraries for the graphical user interface and graphical display coupled with a solid-modeling data structure that utilizes a structured grid generation library and a geometric library based on Non-Uniform Rational B-Splines (NURBS). A presented modification of the solid-modeling data structure provides the capability for arbitrarily-connected regions between the grid blocks. The presented grid generation library provides algorithms that are reliable and accurate. GUM-B has been utilized to generate numerous structured grids for complex geometries in hydrodynamics, propulsors, and aerodynamics. The versatility of the libraries that compose GUM-B is also displayed in a prototype to automatically regenerate a grid for a free-surface solution. Grid decomposition and solver setup is accomplished with the graphical grid manipulation and repartition software system (GUMBO) developed and presented here. GUMBO is an integrated system comprised of specialized libraries for the graphical user interface and graphical display coupled with a structured grid-tools library. The described functions within the grid-tools library reduce the possibility of human error during decomposition and setup for the numerical solver by accounting for boundary conditions and connectivity. GUMBO is linked with a flow solver interface, to the parallel UNCLE code, to provide load balancing tools and solver setup. Weeks of boundary condition and connectivity specification and validation has been reduced to hours. The UNCLE flow solver is utilized for the solution of the flow field. To accelerate convergence toward a quick engineering answer, a full multigrid (FMG) approach coupled with UNCLE, which is a full approximation scheme (FAS), is presented. The prolongation operators used in the FMG-FAS method are compared. The procedure is demonstrated on a marine propeller in incompressible flow. Interpretation of the solution is accomplished by vortex feature detection. Regions of "Intrinsic Swirl" are located by interrogating the velocity gradient tensor for complex eigenvalues. The "Intrinsic Swirl" parameter is visualized on a solution of a marine propeller to determine if any vortical features are captured. The libraries and the structured grid technology presented herein are flexible and general enough to tackle a variety of complex applications. This technology has significantly enabled the capability of the ERC personnel to effectively calculate solutions for complex geometries.
A Workstation for Interactive Display and Quantitative Analysis of 3-D and 4-D Biomedical Images
Robb, R.A.; Heffeman, P.B.; Camp, J.J.; Hanson, D.P.
1986-01-01
The capability to extract objective and quantitatively accurate information from 3-D radiographic biomedical images has not kept pace with the capabilities to produce the images themselves. This is rather an ironic paradox, since on the one hand the new 3-D and 4-D imaging capabilities promise significant potential for providing greater specificity and sensitivity (i.e., precise objective discrimination and accurate quantitative measurement of body tissue characteristics and function) in clinical diagnostic and basic investigative imaging procedures than ever possible before, but on the other hand, the momentous advances in computer and associated electronic imaging technology which have made these 3-D imaging capabilities possible have not been concomitantly developed for full exploitation of these capabilities. Therefore, we have developed a powerful new microcomputer-based system which permits detailed investigations and evaluation of 3-D and 4-D (dynamic 3-D) biomedical images. The system comprises a special workstation to which all the information in a large 3-D image data base is accessible for rapid display, manipulation, and measurement. The system provides important capabilities for simultaneously representing and analyzing both structural and functional data and their relationships in various organs of the body. This paper provides a detailed description of this system, as well as some of the rationale, background, theoretical concepts, and practical considerations related to system implementation. ImagesFigure 5Figure 7Figure 8Figure 9Figure 10Figure 11Figure 12Figure 13Figure 14Figure 15Figure 16
ERIC Educational Resources Information Center
Murph, Debra; McCormick, Sandra
1985-01-01
A 12-step procedure was used in teaching five minimally literate, male juvenile offenders to read and interpret prototypes of road signs displaying words, and a 5-step procedure for interpreting a sign without words. All students' correct responses in reading and interpreting signs increased and were maintained during subsequent post-checks.…
Free Flight and Self-Separation from the Flight Deck Perspective
NASA Technical Reports Server (NTRS)
Lozito, Sandra; McGann, Alison; Mackintosh, Margaret-Anne; Cashion, Patricia; Shafto, Michael G. (Technical Monitor)
1997-01-01
The concept of "free flight", while still being developed, is intended to emphasize more, flexibility for operators in the National Airspace System (NAS) by providing more separation responsibility to pilots, New technologies, procedures, and concepts have been suggested by the aviation community to enable this task; however, much work needs to be accomplished to help define and evaluate the concept feasibility. The purpose of this simulation was to begin examining some of the communication and procedural issues associated with self-separation in the enroute environment. A simulation demonstration was conducted in the Boeing 747-400 simulator at NASA Ames Research Center. Commercial pilots (from a U.S. domestic carrier) current on the B747-400 aircraft were the participants. Ten flight crews (10 captains, 10 first officers) flew in the Denver enroute airspace environment. A new alerting logic designed to allow for airborne self-separation was created for this demonstration. This logic assumes automatic dependent surveillance broadcast (ADS-B) capability and represented aircraft up to 120 nautical miles on the display. The new flight deck display features were designed and incorporated on the existing navigational display in the simulator to allow for increased traffic and maneuvering information to the flight crew. New tools were also provided to allow the crews to assess conflicts and potential maneuvers before implementing them. Each of the flight crews flew eight different scenarios in the Denver enroute airspace. The scenarios included eight to ten other aircraft, and each scenario was created with the intent of having one of the other aircraft become an operational conflict for our simulator aircraft. Different types of conflict geometries were represented across the eight scenarios. Also, some scenarios allowed for more time to detect a potential clearance, while others allowed for less time for'detection. Additionally, the crews were asked to a ply the Visual Flight Rules (VFR) right of way rules when determining who should maneuver in a conflict situation; therefore, the scenarios were designed to test different applications of those recommendations, Data analyses include an evaluation of crew procedures and communication. The application of the VFR right-of-way rules are being explored. Timing variables are being examined to determine potential efficiency differences between scenarios and conflict types. Proximity of aircraft will be assessed as one indication of the operational safety. The intent of these evaluations is to help provide definitions and guidelines of negotiation procedures in a self-separation environment assuming automated data link technology (ADS-B). Also, definitions of likely flight crew maneuvers and application to current VFR right-of-way rules may be obtained, along with guidelines for negotiation procedures between flight crews.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oxstrand, Johanna; Le Blanc, Katya L.; Bly, Aaron
The paper-based procedures currently used for nearly all activities in the commercial nuclear power industry have a long history of ensuring safe operation of the plants. However, there is potential to greatly increase efficiency and safety by improving how the human operator interacts with the procedures. One way to achieve these improvements is through the use of computer-based procedures (CBPs). A CBP system offers a vast variety of improvements, such as context driven job aids, integrated human performance tools (e.g., placekeeping, correct component verification, etc.), and dynamic step presentation. The latter means that the CBP system could only display relevantmore » steps based on operating mode, plant status, and the task at hand. A dynamic presentation of the procedure (also known as context-sensitive procedures) will guide the operator down the path of relevant steps based on the current conditions. This feature will reduce the operator’s workload and inherently reduce the risk of incorrectly marking a step as not applicable and the risk of incorrectly performing a step that should be marked as not applicable. The research team at the Idaho National Laboratory has developed a prototype CBP system for field workers, which has been evaluated from a human factors and usability perspective in four laboratory studies. Based on the results from each study revisions were made to the CBP system. However, a crucial step to get the end users' (e.g., auxiliary operators, maintenance technicians, etc.) acceptance is to put the system in their hands and let them use it as a part of their everyday work activities. In the spring 2014 the first field evaluation of the INL CBP system was conducted at a nuclear power plant. Auxiliary operators conduct a functional test of one out of three backup air compressors each week. During the field evaluation activity, one auxiliary operator conducted the test with the paper-based procedure while a second auxiliary operator followed along with the computer-based procedure. After each conducted functional test the operators were asked a series of questions designed to provide feedback on the feasibility to use a CBP system in the plant and the general user experience of the CBP system. This paper will describe the field evaluation and its results in detail. For example, the result shows that the context driven job aids and the incorporated human performance tools are much liked by the auxiliary operators. The paper will describe and present initial findings from a second field evaluation conducted at second nuclear utility. For this field evaluation a preventive maintenance work order for the HVAC system was used. In addition, there will be a description of the method and objective of two field evaluations planned to be conducted late 2014 or early 2015.« less
Features and limitations of mobile tablet devices for viewing radiological images.
Grunert, J H
2015-03-01
Mobile radiological image display systems are becoming increasingly common, necessitating a comparison of the features of these systems, specifically the operating system employed, connection to stationary PACS, data security and rang of image display and image analysis functions. In the fall of 2013, a total of 17 PACS suppliers were surveyed regarding the technical features of 18 mobile radiological image display systems using a standardized questionnaire. The study also examined to what extent the technical specifications of the mobile image display systems satisfy the provisions of the Germany Medical Devices Act as well as the provisions of the German X-ray ordinance (RöV). There are clear differences in terms of how the mobile systems connected to the stationary PACS. Web-based solutions allow the mobile image display systems to function independently of their operating systems. The examined systems differed very little in terms of image display and image analysis functions. Mobile image display systems complement stationary PACS and can be used to view images. The impacts of the new quality assurance guidelines (QS-RL) as well as the upcoming new standard DIN 6868 - 157 on the acceptance testing of mobile image display units for the purpose of image evaluation are discussed. © Georg Thieme Verlag KG Stuttgart · New York.
Enhanced visualization of inner ear structures
NASA Astrophysics Data System (ADS)
Niemczyk, Kazimierz; Kucharski, Tomasz; Kujawinska, Malgorzata; Bruzgielewicz, Antoni
2004-07-01
Recently surgery requires extensive support from imaging technologies in order to increase effectiveness and safety of operations. One of important tasks is to enhance visualisation of quasi-phase (transparent) 3d structures. Those structures are characterized by very low contrast. It makes differentiation of tissues in field of view very difficult. For that reason the surgeon may be extremly uncertain during operation. This problem is connected with supporting operations of inner ear during which physician has to perform cuts at specific places of quasi-transparent velums. Conventionally during such operations medical doctor views the operating field through stereoscopic microscope. In the paper we propose a 3D visualisation system based on Helmet Mounted Display. Two CCD cameras placed at the output of microscope perform acquisition of stereo pairs of images. The images are processed in real-time with the goal of enhancement of quasi-phased structures. The main task is to create algorithm that is not sensitive to changes in intensity distribution. The disadvantages of existing algorithms is their lack of adaptation to occuring reflexes and shadows in field of view. The processed images from both left and right channels are overlaid on the actual images exported and displayed at LCD's of Helmet Mounted Display. A physician observes by HMD (Helmet Mounted Display) a stereoscopic operating scene with indication of the places of special interest. The authors present the hardware ,procedures applied and initial results of inner ear structure visualisation. Several problems connected with processing of stereo-pair images are discussed.
Wentink, M; Jakimowicz, J J; Vos, L M; Meijer, D W; Wieringa, P A
2002-08-01
Compared to open surgery, minimally invasive surgery (MIS) relies heavily on advanced technology, such as endoscopic viewing systems and innovative instruments. The aim of the study was to objectively compare three technologically advanced laparoscopic viewing systems with the standard viewing system currently used in most Dutch hospitals. We evaluated the following advanced laparoscopic viewing systems: a Thin Film Transistor (TFT) display, a stereo endoscope, and an image projection display. The standard viewing system was comprised of a monocular endoscope and a high-resolution monitor. Task completion time served as the measure of performance. Eight surgeons with laparoscopic experience participated in the experiment. The average task time was significantly greater (p <0.05) with the stereo viewing system than with the standard viewing system. The average task times with the TFT display and the image projection display did not differ significantly from the standard viewing system. Although the stereo viewing system promises improved depth perception and the TFT and image projection displays are supposed to improve hand-eye coordination, none of these systems provided better task performance than the standard viewing system in this pelvi-trainer experiment.
2009-12-01
forward-looking infrared FOV field-of-view HDU helmet display unit HMD helmet-mounted display IHADSS Integrated Helmet and Display...monocular Integrated Helmet and Display Sighting System (IHADSS) helmet-mounted display ( HMD ) in the British Army’s Apache AH Mk 1 attack helicopter has any...Integrated Helmet and Display Sighting System, IHADSS, Helmet-mounted display, HMD , Apache helicopter, Visual performance UNCLAS UNCLAS UNCLAS SAR 96
DeltaPhage—a novel helper phage for high-valence pIX phagemid display
Nilssen, Nicolay R.; Frigstad, Terje; Pollmann, Sylvie; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger; Løset, Geir Å.
2012-01-01
Phage display has been instrumental in discovery of novel binding peptides and folded domains for the past two decades. We recently reported a novel pIX phagemid display system that is characterized by a strong preference for phagemid packaging combined with low display levels, two key features that support highly efficient affinity selection. However, high diversity in selected repertoires are intimately coupled to high display levels during initial selection rounds. To incorporate this additional feature into the pIX display system, we have developed a novel helper phage termed DeltaPhage that allows for high-valence display on pIX. This was obtained by inserting two amber mutations close to the pIX start codon, but after the pVII translational stop, conditionally inactivating the helper phage encoded pIX. Until now, the general notion has been that display on pIX is dependent on wild-type complementation, making high-valence display unachievable. However, we found that DeltaPhage does facilitate high-valence pIX display when used with a non-suppressor host. Here, we report a side-by-side comparison with pIII display, and we find that this novel helper phage complements existing pIX phagemid display systems to allow both low and high-valence display, making pIX display a complete and efficient alternative to existing pIII phagemid display systems. PMID:22539265
DeltaPhage--a novel helper phage for high-valence pIX phagemid display.
Nilssen, Nicolay R; Frigstad, Terje; Pollmann, Sylvie; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger; Løset, Geir Å
2012-09-01
Phage display has been instrumental in discovery of novel binding peptides and folded domains for the past two decades. We recently reported a novel pIX phagemid display system that is characterized by a strong preference for phagemid packaging combined with low display levels, two key features that support highly efficient affinity selection. However, high diversity in selected repertoires are intimately coupled to high display levels during initial selection rounds. To incorporate this additional feature into the pIX display system, we have developed a novel helper phage termed DeltaPhage that allows for high-valence display on pIX. This was obtained by inserting two amber mutations close to the pIX start codon, but after the pVII translational stop, conditionally inactivating the helper phage encoded pIX. Until now, the general notion has been that display on pIX is dependent on wild-type complementation, making high-valence display unachievable. However, we found that DeltaPhage does facilitate high-valence pIX display when used with a non-suppressor host. Here, we report a side-by-side comparison with pIII display, and we find that this novel helper phage complements existing pIX phagemid display systems to allow both low and high-valence display, making pIX display a complete and efficient alternative to existing pIII phagemid display systems.
NASA Technical Reports Server (NTRS)
Granaas, Michael M.; Rhea, Donald C.
1989-01-01
In recent years the needs of ground-based researcher-analysts to access real-time engineering data in the form of processed information has expanded rapidly. Fortunately, the capacity to deliver that information has also expanded. The development of advanced display systems is essential to the success of a research test activity. Those developed at the National Aeronautics and Space Administration (NASA), Western Aeronautical Test Range (WATR), range from simple alphanumerics to interactive mapping and graphics. These unique display systems are designed not only to meet basic information display requirements of the user, but also to take advantage of techniques for optimizing information display. Future ground-based display systems will rely heavily not only on new technologies, but also on interaction with the human user and the associated productivity with that interaction. The psychological abilities and limitations of the user will become even more important in defining the difference between a usable and a useful display system. This paper reviews the requirements for development of real-time displays; the psychological aspects of design such as the layout, color selection, real-time response rate, and interactivity of displays; and an analysis of some existing WATR displays.
Zheng, Hao; Wang, Xiong; Ren, Feifei; Zou, Shenglong; Feng, Min; Xu, Liangliang; Yao, Lunguang; Sun, Jingchen
2018-06-19
The classical baculovirus display system (BDS) has often recruited fields including gene delivery, gene therapy, and the genetic engineering of vaccines, as it is capable of presenting foreign polypeptides on the membranes of recombinant baculovirus through a transmembrane protein. However, classical BDS's high cost, complicated operation, low display efficiency and its inability to simultaneously display multiple gene products impede its practicality. In this study, we present a novel and highly efficient display system based on ires-dependent gp64 for rescuing gp64-null Bacmid of baculovirus construction without affecting the viral replication cycle, which we name the baculovirus multigene display system (BMDS). Laser scanning confocal microscopy demonstrated that eGFP, eYFP, and mCherry were translocated on the membrane of Spodoptera frugiperda 9 cell successfully as expected. Western blot analysis further confirmed the presence of the fluorescent proteins on the budded, mature viral particles. The results showed the display efficiency of target gene on cell surface is fourfold that of classical BDS. In addition, a recombinant baculovirus displaying three kinds of fluorescent proteins simultaneously was constructed, thereby demonstrating the effectiveness of BMDS as a co-display system.
Functional display of family 11 endoxylanases on the surface of phage M13.
Beliën, T; Hertveldt, K; Van den Brande, K; Robben, J; Van Campenhout, S; Volckaert, G
2005-02-09
Two family 11 endoxylanases (EC 3.2.1.8) were functionally displayed on the surface of bacteriophage M13. The genes encoding endo-1,4-xylanase I from Aspergillus niger (ExlA) and endo-1,4-xylanase A from Bacillus subtilis (XynA) were fused to the gene encoding the minor coat protein g3p in phagemid vector pHOS31. Phage rescue resulted in functional monovalent display of the enzymes as was demonstrated by three independent tests. Firstly, purified recombinant phage particles showed a clear hydrolytic activity in an activity assay based on insoluble, chromagenic arabinoxylan substrate. Secondly, specific binding of endoxylanase displaying phages to immobilized endoxylanase inhibitors was demonstrated by interaction ELISA. Finally, two rounds of selection and amplification in a biopanning procedure against immobilized endoxylanase inhibitor were performed. Phages displaying endoxylanases were strongly enriched from background phages displaying unrelated proteins. These results open perspectives to use phage display for analysing protein-protein interactions at the interface between endoxylanases and their inhibitors. In addition, this technology should enable engineering of endoxylanases into novel variants with altered binding properties towards endoxylanase inhibitors.
Time delays in flight simulator visual displays
NASA Technical Reports Server (NTRS)
Crane, D. F.
1980-01-01
It is pointed out that the effects of delays of less than 100 msec in visual displays on pilot dynamic response and system performance are of particular interest at this time because improvements in the latest computer-generated imagery (CGI) systems are expected to reduce CGI displays delays to this range. Attention is given to data which quantify the effects of display delays in the range of 0-100 msec on system stability and performance, and pilot dynamic response for a particular choice of aircraft dynamics, display, controller, and task. The conventional control system design methods are reviewed, the pilot response data presented, and data for long delays, all suggest lead filter compensation of display delay. Pilot-aircraft system crossover frequency information guides compensation filter specification.
Six-Message Electromechanical Display System
NASA Technical Reports Server (NTRS)
Howard, Richard T.
2007-01-01
A proposed electromechanical display system would be capable of presenting as many as six distinct messages. In the proposed system, each display element would include a cylinder having a regular hexagonal cross section.
Filamentous bacteriophage as a novel therapeutic tool for Alzheimer's disease treatment.
Solomon, Beka
2008-10-01
Antibodies towards the N-terminal region of the amyloid-beta peptide (AbetaP) bind to Abeta fibrils, leading to their disaggregation. We developed an immunization procedure using filamentous phages displaying the only four amino acids EFRH encompassing amino acids 3-6 of the 42 residues of AbetaP, found to be the main regulatory site for Abeta formation. Phages displaying EFRH epitope are effective in eliciting humoral response against AbetaP which, in turn, relieves amyloid burden in brains of amyloid-beta protein precursor transgenic mice, improving their ability to perform cognitive tasks. In order to overcome the low permeability of the blood brain barrier for targeting 'anti-aggregating' monoclonal antibodies (mAbs) to Abeta plaques in the brain, we applied antibody engineering methods to minimize the size of mAbs while maintaining their biological activity. Single-chain antibodies displayed on the surface of filamentous phage showed the ability to enter the central nervous system (CNS). The genetically engineered filamentous bacteriophage proved to be an efficient, nontoxic viral delivery vector to the brain, offering an obvious advantage over other mammalian vectors. The feasibility of these novel strategies for production and targeting of anti-aggregating antibodies against Abeta plaques to disease affected regions in the CNS may have clinical potential for treatment of Alzheimer's disease.
Burns-Nader, Sherwood; Joe, Lindsay; Pinion, Kelly
2017-09-01
Distraction is often used in conjunction with analgesics to minimize pain in pediatric burn patients during treatment procedures. Computer tablets provide many options for distraction items in one tool and are often used during medical procedures. Few studies have examined the effectiveness of tablet distraction in improving the care of pediatric burn patients. This study examines the effectiveness of tablet distraction provided by a child life specialist to minimize pain and anxiety in pediatric burn patients undergoing hydrotherapy. Thirty pediatric patients (4-12) undergoing hydrotherapy for the treatment of burns participated in this randomized clinical trial. The tablet distraction group received tablet distraction provided by a child life specialist while those in the control group received standard care. Pain was assessed through self-reports and observation reports. Anxiety was assessed through behavioral observations. Length of procedure was also recorded. Nurses reported significantly less pain for the tablet distraction group compared to the control group. There was no significant difference between groups on self-reported pain. The tablet distraction group displayed significantly less anxiety during the procedure compared to the control group. Also, the tablet distraction group returned to baseline after the procedure while those in the control group displayed higher anxiety post-procedure. There was no difference in the length of the procedure between groups. These findings suggest tablet distraction provided by a child life specialist may be an effective method for improving pain and anxiety in children undergoing hydrotherapy treatment for burns. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.
Dual use display systems for telerobotics
NASA Technical Reports Server (NTRS)
Massimino, Michael J.; Meschler, Michael F.; Rodriguez, Alberto A.
1994-01-01
This paper describes a telerobotics display system, the Multi-mode Manipulator Display System (MMDS), that has applications for a variety of remotely controlled tasks. Designed primarily to assist astronauts with the control of space robotics systems, the MMDS has applications for ground control of space robotics as well as for toxic waste cleanup, undersea, remotely operated vehicles, and other environments which require remote operations. The MMDS has three modes: (1) Manipulator Position Display (MPD) mode, (2) Joint Angle Display (JAD) mode, and (3) Sensory Substitution (SS) mode. These three modes are discussed in the paper.
Tesoriero, Ricardo; Gallud Lazaro, Jose A; Altalhi, Abdulrahman H
2017-02-01
Improve the quantity and quality of information obtained from traditional Loewenstein Occupational Therapy Cognitive Assessment Battery systems to monitor the evolution of patients' rehabilitation process as well as to compare different rehabilitation therapies. The system replaces traditional artefacts with virtual versions of them to take advantage of cutting edge interaction technology. The system is defined as a Distributed User Interface (DUI) supported by a display ecosystem, including mobile devices as well as multi-touch surfaces. Due to the heterogeneity of the devices involved in the system, the software technology is based on a client-server architecture using the Web as the software platform. The system provides therapists with information that is not available (or it is very difficult to gather) using traditional technologies (i.e. response time measurements, object tracking, information storage and retrieval facilities, etc.). The use of DUIs allows therapists to gather information that is unavailable using traditional assessment methods as well as adapt the system to patients' profile to increase the range of patients that are able to take this assessment. Implications for Rehabilitation Using a Distributed User Interface environment to carry out LOTCAs improves the quality of the information gathered during the rehabilitation assessment. This system captures physical data regarding patient's interaction during the assessment to improve the rehabilitation process analysis. Allows professionals to adapt the assessment procedure to create different versions according to patients' profile. Improves the availability of patients' profile information to therapists to adapt the assessment procedure.
An intelligent control and virtual display system for evolutionary space station workstation design
NASA Technical Reports Server (NTRS)
Feng, Xin; Niederjohn, Russell J.; Mcgreevy, Michael W.
1992-01-01
Research and development of the Advanced Display and Computer Augmented Control System (ADCACS) for the space station Body-Ported Cupola Virtual Workstation (BP/VCWS) were pursued. The potential applications were explored of body ported virtual display and intelligent control technology for the human-system interfacing applications is space station environment. The new system is designed to enable crew members to control and monitor a variety of space operations with greater flexibility and efficiency than existing fixed consoles. The technologies being studied include helmet mounted virtual displays, voice and special command input devices, and microprocessor based intelligent controllers. Several research topics, such as human factors, decision support expert systems, and wide field of view, color displays are being addressed. The study showed the significant advantages of this uniquely integrated display and control system, and its feasibility for human-system interfacing applications in the space station command and control environment.
Redesigning of Microbial Cell Surface and Its Application to Whole-Cell Biocatalysis and Biosensors.
Han, Lei; Zhao, Yukun; Cui, Shan; Liang, Bo
2018-06-01
Microbial cell surface display technology can redesign cell surfaces with functional proteins and peptides to endow cells some unique features. Foreign peptides or proteins are transported out of cells and immobilized on cell surface by fusing with anchoring proteins, which is an effective solution to avoid substance transfer limitation, enzyme purification, and enzyme instability. As the most frequently used prokaryotic and eukaryotic protein surface display system, bacterial and yeast surface display systems have been widely applied in vaccine, biocatalysis, biosensor, bioadsorption, and polypeptide library screening. In this review of bacterial and yeast surface display systems, different cell surface display mechanisms and their applications in biocatalysis as well as biosensors are described with their strengths and shortcomings. In addition to single enzyme display systems, multi-enzyme co-display systems are presented here. Finally, future developments based on our and other previous reports are discussed.
Desmottes, Lise; Meulemans, Thierry; Maillart, Christelle
2016-01-01
According to the Procedural Deficit Hypothesis (PDH), difficulties in the procedural memory system may contribute to the language difficulties encountered by children with Specific Language Impairment (SLI). Most studies investigating the PDH have used the sequence learning paradigm; however these studies have principally focused on initial sequence learning in a single practice session. The present study sought to extend these investigations by assessing the consolidation stage and longer-term retention of implicit sequence-specific knowledge in 42 children with or without SLI. Both groups of children completed a serial reaction time task and were tested 24h and one week after practice. Results showed that children with SLI succeeded as well as children with typical development (TD) in the early acquisition stage of the sequence learning task. However, as training blocks progressed, only TD children improved their sequence knowledge while children with SLI did not appear to evolve any more. Moreover, children with SLI showed a lack of the consolidation gains in sequence knowledge displayed by the TD children. Overall, these results were in line with the predictions of the PDH and suggest that later learning stages in procedural memory are impaired in SLI. Copyright © 2015 Elsevier Ltd. All rights reserved.
Selection of stable scFv antibodies by phage display.
Brockmann, Eeva-Christine
2012-01-01
ScFv fragments are popular recombinant antibody formats but often suffer from limited stability. Phage display is a powerful tool in antibody engineering and applicable also for stability selection. ScFv variants with improved stability can be selected from large randomly mutated phage displayed libraries with a specific antigen after the unstable variants have been inactivated by heat or GdmCl. Irreversible scFv denaturation, which is a prerequisite for efficient selection, is achieved by combining denaturation with reduction of the intradomain disulfide bonds. Repeated selection cycles of increasing stringency result in enrichment of stabilized scFv fragments. Procedures for constructing a randomly mutated scFv library by error-prone PCR and phage display selection for enrichment of stable scFv antibodies from the library are described here.
NASA Astrophysics Data System (ADS)
Kucera, P. A.; Burek, T.; Halley-Gotway, J.
2015-12-01
NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.
Meng, Hu; Li, Jiang-Yuan; Tang, Yong-Huai
2009-01-01
The virtual instrument system based on LabVIEW 8.0 for ion analyzer which can measure and analyze ion concentrations in solution is developed and comprises homemade conditioning circuit, data acquiring board, and computer. It can calibrate slope, temperature, and positioning automatically. When applied to determine the reaction rate constant by pX, it achieved live acquiring, real-time displaying, automatical processing of testing data, generating the report of results; and other functions. This method simplifies the experimental operation greatly, avoids complicated procedures of manual processing data and personal error, and improves veracity and repeatability of the experiment results.
SSL: A software specification language
NASA Technical Reports Server (NTRS)
Austin, S. L.; Buckles, B. P.; Ryan, J. P.
1976-01-01
SSL (Software Specification Language) is a new formalism for the definition of specifications for software systems. The language provides a linear format for the representation of the information normally displayed in a two-dimensional module inter-dependency diagram. In comparing SSL to FORTRAN or ALGOL, it is found to be largely complementary to the algorithmic (procedural) languages. SSL is capable of representing explicitly module interconnections and global data flow, information which is deeply imbedded in the algorithmic languages. On the other hand, SSL is not designed to depict the control flow within modules. The SSL level of software design explicitly depicts intermodule data flow as a functional specification.
Piloting considerations for terminal area operations of civil tiltwing and tiltrotor aircraft
NASA Technical Reports Server (NTRS)
Hindson, William S.; Hardy, Gordon H.; Tucker, George E.; Decker, William A.
1993-01-01
The existing body of research to investigate airworthiness, performance, handling, and operational requirements for STOL and V/STOL aircraft was reviewed for its applicability to the tiltrotor and tiltwing design concepts. The objective of this study was to help determine the needs for developing civil certification criteria for these aircraft concepts. Piloting tasks that were considered included configuration and thrust vector management, glidepath control, deceleration to hover, and engine failure procedures. Flight control and cockpit display systems that have been found necessary to exploit the low-speed operating characteristics of these aircraft are described, and beneficial future developments are proposed.