Sample records for procedures technical factors

  1. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  2. Safety in the operating room during orthopedic trauma surgery-incidence of adverse events related to technical equipment and logistics.

    PubMed

    van Delft, E A K; Schepers, T; Bonjer, H J; Kerkhoffs, G M M J; Goslings, J C; Schep, N W L

    2018-04-01

    Safety in the operating room is widely debated. Adverse events during surgery are potentially dangerous for the patient and staff. The incidence of adverse events during orthopedic trauma surgery is unknown. Therefore, we performed a study to quantify the incidence of these adverse events. Primary objective was to determine the incidence of adverse events related to technical equipment and logistics. The secondary objective was to evaluate the consequences of these adverse events. We completed a cross-sectional observational study to assess the incidence, consequences and preventability of adverse events related to technical equipment and logistics during orthopedic trauma surgery. During a 10 week period, all orthopedic trauma operations were evaluated by an observer. Six types of procedures were differentiated: osteosynthesis; arthroscopy; removal of hardware; joint replacement; bone grafting and other. Adverse events were divided in six categories: staff dependent factors; patient dependent factors; anaesthesia; imaging equipment; operation room equipment and instruments and implants. Adverse events were defined as any factor affecting the surgical procedure in a negative way. Hundred-fifty operative procedures were included. In 54% of the procedures, at least one adverse event occurred. In total, 147 adverse events occurred, with a range of 1-5 per procedure. Most adverse events occurred during joint replacement procedures. Thirty-seven percent of the incidents concerned defect, incorrect connected or absent instruments. In 36% of the procedures adverse events resulted in a prolonged operation time with a median prolongation of 10.0 min. In more than half of orthopedic trauma surgical procedures adverse events related to technical equipment and logistics occurred, most of them could easily be prevented. These adverse events could endanger the safety of the patient and staff and should therefore be reduced. 4.

  3. Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures

    PubMed Central

    Journy, N; Sinno-Tellier, S; Maccia, C; Le Tertre, A; Pirard, P; Pagès, P; Eilstein, D; Donadieu, J; Bar, O

    2012-01-01

    Objective The study aimed to characterise the factors related to the X-ray dose delivered to the patient's skin during interventional cardiology procedures. Methods We studied 177 coronary angiographies (CAs) and/or percutaneous transluminal coronary angioplasties (PTCAs) carried out in a French clinic on the same radiography table. The clinical and therapeutic characteristics, and the technical parameters of the procedures, were collected. The dose area product (DAP) and the maximum skin dose (MSD) were measured by an ionisation chamber (Diamentor; Philips, Amsterdam, The Netherlands) and radiosensitive film (Gafchromic; International Specialty Products Advanced Materials Group, Wayne, NJ). Multivariate analyses were used to assess the effects of the factors of interest on dose. Results The mean MSD and DAP were respectively 389 mGy and 65 Gy cm−2 for CAs, and 916 mGy and 69 Gy cm−2 for PTCAs. For 8% of the procedures, the MSD exceeded 2 Gy. Although a linear relationship between the MSD and the DAP was observed for CAs (r=0.93), a simple extrapolation of such a model to PTCAs would lead to an inadequate assessment of the risk, especially for the highest dose values. For PTCAs, the body mass index, the therapeutic complexity, the fluoroscopy time and the number of cine frames were independent explanatory factors of the MSD, whoever the practitioner was. Moreover, the effect of technical factors such as collimation, cinematography settings and X-ray tube orientations on the DAP was shown. Conclusion Optimising the technical options for interventional procedures and training staff on radiation protection might notably reduce the dose and ultimately avoid patient skin lesions. PMID:22457404

  4. ARC-2011-ACD11-0152-006

    NASA Image and Video Library

    2011-08-25

    Aeronautics Technical Seminar with Dennis Koehler, Vice President, Science Applications International Corporation (and former FAA executive) presenting 'Beyond the Technical: Procedural, Operational and Economic Factors 'POET' for NextGen Success

  5. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    PubMed

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Raj, E-mail: rajdas@nhs.net, E-mail: raj.das@stgeorges.nhs.uk; Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com; Wang, Haofan, E-mail: wwhhff123@gmail.com

    AimA clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill.MethodsTen IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to threemore » groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters).ResultsMean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %.ConclusionUAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.« less

  7. Operational Interventions to Maintenance Error

    NASA Technical Reports Server (NTRS)

    Kanki, Barbara G.; Walter, Diane; Dulchinos, VIcki

    1997-01-01

    A significant proportion of aviation accidents and incidents are known to be tied to human error. However, research of flight operational errors has shown that so-called pilot error often involves a variety of human factors issues and not a simple lack of individual technical skills. In aircraft maintenance operations, there is similar concern that maintenance errors which may lead to incidents and accidents are related to a large variety of human factors issues. Although maintenance error data and research are limited, industry initiatives involving human factors training in maintenance have become increasingly accepted as one type of maintenance error intervention. Conscientious efforts have been made in re-inventing the team7 concept for maintenance operations and in tailoring programs to fit the needs of technical opeRAtions. Nevertheless, there remains a dual challenge: 1) to develop human factors interventions which are directly supported by reliable human error data, and 2) to integrate human factors concepts into the procedures and practices of everyday technical tasks. In this paper, we describe several varieties of human factors interventions and focus on two specific alternatives which target problems related to procedures and practices; namely, 1) structured on-the-job training and 2) procedure re-design. We hope to demonstrate that the key to leveraging the impact of these solutions comes from focused interventions; that is, interventions which are derived from a clear understanding of specific maintenance errors, their operational context and human factors components.

  8. Reduction of Maintenance Error Through Focused Interventions

    NASA Technical Reports Server (NTRS)

    Kanki, Barbara G.; Walter, Diane; Rosekind, Mark R. (Technical Monitor)

    1997-01-01

    It is well known that a significant proportion of aviation accidents and incidents are tied to human error. In flight operations, research of operational errors has shown that so-called "pilot error" often involves a variety of human factors issues and not a simple lack of individual technical skills. In aircraft maintenance operations, there is similar concern that maintenance errors which may lead to incidents and accidents are related to a large variety of human factors issues. Although maintenance error data and research are limited, industry initiatives involving human factors training in maintenance have become increasingly accepted as one type of maintenance error intervention. Conscientious efforts have been made in re-inventing the "team" concept for maintenance operations and in tailoring programs to fit the needs of technical operations. Nevertheless, there remains a dual challenge: to develop human factors interventions which are directly supported by reliable human error data, and to integrate human factors concepts into the procedures and practices of everyday technical tasks. In this paper, we describe several varieties of human factors interventions and focus on two specific alternatives which target problems related to procedures and practices; namely, 1) structured on-the-job training and 2) procedure re-design. We hope to demonstrate that the key to leveraging the impact of these solutions comes from focused interventions; that is, interventions which are derived from a clear understanding of specific maintenance errors, their operational context and human factors components.

  9. Development of an accelerated creep testing procedure for geosynthetics : technical summary.

    DOT National Transportation Integrated Search

    1997-09-01

    Temperature-creep relationships in geosynthetics vary for each type of geogrid and depend on many factors such as polymer structure, manufacture process, degree of crystallinity, and glass-transition temperature. The extrapolation procedures to predi...

  10. A Human Factors Analysis of Technical and Team Skills Among Surgical Trainees During Procedural Simulations in a Simulated Operating Theatre

    PubMed Central

    Moorthy, Krishna; Munz, Yaron; Adams, Sally; Pandey, Vikas; Darzi, Ara

    2005-01-01

    Background: High-risk organizations such as aviation rely on simulations for the training and assessment of technical and team performance. The aim of this study was to develop a simulated environment for surgical trainees using similar principles. Methods: A total of 27 surgical trainees carried out a simulated procedure in a Simulated Operating Theatre with a standardized OR team. Observation of OR events was carried out by an unobtrusive data collection system: clinical data recorder. Assessment of performance consisted of blinded rating of technical skills, a checklist of technical events, an assessment of communication, and a global rating of team skills by a human factors expert and trained surgical research fellows. The participants underwent a debriefing session, and the face validity of the simulated environment was evaluated. Results: While technical skills rating discriminated between surgeons according to experience (P = 0.002), there were no differences in terms of the checklist and team skills (P = 0.70). While all trainees were observed to gown/glove and handle sharps correctly, low scores were observed for some key features of communication with other team members. Low scores were obtained by the entire cohort for vigilance. Interobserver reliability was 0.90 and 0.89 for technical and team skills ratings. Conclusions: The simulated operating theatre could serve as an environment for the development of surgical competence among surgical trainees. Objective, structured, and multimodal assessment of performance during simulated procedures could serve as a basis for focused feedback during training of technical and team skills. PMID:16244534

  11. Predictive factors for outcomes of patients undergoing endoscopic therapy for bile leak after hepatobiliary surgery.

    PubMed

    Yabe, Shuntaro; Kato, Hironari; Mizukawa, Sho; Akimoto, Yutaka; Uchida, Daisuke; Seki, Hiroyuki; Tomoda, Takeshi; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki

    2017-05-01

    Endoscopic procedures are used as first-line treatment for bile leak after hepatobiliary surgery. Advances have been made in endoscopic techniques and devices, but few reports have described the effectiveness of endoscopic procedures and the management principles based on severity of bile leak. We evaluated the effectiveness of an endoscopic procedure for the treatment of bile leak after hepatobiliary surgery. Fifty-eight patients underwent an endoscopic procedure for suspected bile leak after hepatobiliary surgery; the presence of bile leak on endoscopic retrograde cholangiopancreatography (ERCP) was evaluated retrospectively. Two groups were created based on bile leak severity at ERCP. We defined success as follows: technical, successful placement of the plastic stent at the intended bile duct; clinical, improvement in symptoms of bile leak; and eventual, disappearance of bile leak at ERCP. We evaluated several factors that influenced the success of the endoscopic procedure and the differences between bile leak severity. Success rates were as follows: technical, 90%; clinical, 79%; and eventual, 71%. Median interval between first endoscopic procedure and achievement of eventual success was 135 days (IQR, 86-257 days). Bile leak severity was the only independent factor associated with eventual success (P = 0.01). Endoscopic therapy is safe and effective for postoperative bile leak. Bile leak severity is the most important factor influencing successful endoscopic therapy. © 2016 Japan Gastroenterological Endoscopy Society.

  12. Feasibility, efficacy, and predictive factors for the technical success of endoscopic nasogallbladder drainage: a prospective study.

    PubMed

    Yane, Kei; Maguchi, Hiroyuki; Katanuma, Akio; Takahashi, Kuniyuki; Osanai, Manabu; Kin, Toshifumi; Takaki, Ryo; Matsumoto, Kazuyuki; Gon, Katsushige; Matsumori, Tomoaki; Tomonari, Akiko; Nojima, Masanori

    2015-03-01

    Several studies have shown the useful-ness of endoscopic nasogallbladder drainage (ENGBD) in patients with acute cholecystitis. However, the procedure is difficult, and factors that affect technical success have not yet been clarified. We conducted a prospective study to eval-uate the technical feasibility, efficacy, and predictive factors for the technical success of ENGBD in patients with acute cholecystitis. All patients with moderate or severe acute cholecystitis who were enrolled underwent ENGBD between April 2009 and April 2011. Patients with surgically altered anatomy or pancreatobiliary malignancies were ex-cluded. The primary outcomes included technical success, clinical success, and complications. Factors that could affect the technical success were also examined. Of the 27 patients who underwent ENGBD during the study period, technical success was achieved in 21 (78%) and clinical improvement was achieved in 20 (95%). Early complications were encountered in four patients (15%). Gallbladder wall thickness (odds ratio [OR], 1.64; 95% confidence interval [CI], 1.08 to 2.47) and age (OR, 1.16; 95% CI, 1.00 to 1.35) were effective predictors of technical failure. ENGBD was effective in resolving acute cholecystitis; however, this modality was technically challenging and had a limited suc-cess rate. Because of technical difficulties, ENGBD should be reserved for limited indications. (Gut Liver, 2015;9239-246).

  13. Human Factors Analysis of Pipeline Monitoring and Control Operations: Final Technical Report

    DOT National Transportation Integrated Search

    2008-11-26

    The purpose of the Human Factors Analysis of Pipeline Monitoring and Control Operations project was to develop procedures that could be used by liquid pipeline operators to assess and manage the human factors risks in their control rooms that may adv...

  14. Determination of need for water soaking period in measurement of concrete volume of permeable voids : technical summary.

    DOT National Transportation Integrated Search

    2016-10-01

    Water permeability of concrete is one of the key factors concerning : many concrete deterioration problems. It is often evaluated indirectly by : measuring the volume of permeable voids through the KT-73 (2012) testing : procedures. These procedures ...

  15. 'Buildings in Use' Study. Technical Factors.

    ERIC Educational Resources Information Center

    Wisconsin Univ., Milwaukee. School of Architecture and Urban Planning.

    The second report of the 'Buildings in Use' study documents the results of over 100 field tests conducted at four elementary schools, as well as discussion of these results and relevant technical specifications and details. The procedural framework used in the Field Tests Manual is followed and test results are rated numerically wherever possible.…

  16. Human Factors and Ergonomics for the Dental Profession.

    PubMed

    Ross, Al

    2016-09-01

    This paper proposes that the science of Human Factors and Ergonomics (HFE) is suitable for wide application in dental education, training and practice to improve safety, quality and efficiency. Three areas of interest are highlighted. First it is proposed that individual and team Non-Technical Skills (NTS), such as communication, leadership and stress management can improve error rates and efficiency of procedures. Secondly, in a physically and technically challenging environment, staff can benefit from ergonomic principles which examine design in supporting safe work. Finally, examination of organizational human factors can help anticipate stressors and plan for flexible responses to multiple, variable demands, and fluctuating resources. Clinical relevance: HFE is an evidence-based approach to reducing error rates and procedural complications, and avoiding problems associated with stress and fatigue. Improved teamwork and organizational planning and efficiency can impact directly on patient outcomes.

  17. Technical approaches for measurement of human errors

    NASA Technical Reports Server (NTRS)

    Clement, W. F.; Heffley, R. K.; Jewell, W. F.; Mcruer, D. T.

    1980-01-01

    Human error is a significant contributing factor in a very high proportion of civil transport, general aviation, and rotorcraft accidents. The technical details of a variety of proven approaches for the measurement of human errors in the context of the national airspace system are presented. Unobtrusive measurements suitable for cockpit operations and procedures in part of full mission simulation are emphasized. Procedure, system performance, and human operator centered measurements are discussed as they apply to the manual control, communication, supervisory, and monitoring tasks which are relevant to aviation operations.

  18. Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.

    PubMed

    Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P

    2008-08-01

    The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.

  19. The Applicability of the ISD 4-Factor Model of Job Analysis in Identifying Task Training Priority in Nine Technical Military Occupational Specialties.

    ERIC Educational Resources Information Center

    Siebold, Guy L.

    Research was conducted to assess the applicability of the Instructional Systems Development (ISD) job analysis procedures to nine technical aviation maintenance military occupational specialties (MOS). Job analysis questionnaires were developed for each of the nine aviation maintenance MOS's. Research teams administered the questionnaires to…

  20. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    PubMed

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (p<0.001), longer transparenchymal distance (p<0.001), and prone position (p=0.027). There was positive correlation between the need for chest tube placement and longer transparenchymal distance (p=0.007) and smaller lesion diameter (p=0.018). Lesions in the left lower lobe had the lowest rates of pneumothorax (p=0.008) and chest tube drainage (p=0.018). Patients whose pneumothoraces were diagnosed on the follow-up chest X-ray, but not on the immediate post-procedural CT scan had significantly higher requirement for chest tube drainage (p=0.039). CT-guided lung biopsy has a high rate of technical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Technical Performance as a Predictor of Clinical Outcomes in Laparoscopic Gastric Cancer Surgery.

    PubMed

    Fecso, Andras B; Bhatti, Junaid A; Stotland, Peter K; Quereshy, Fayez A; Grantcharov, Teodor P

    2018-03-23

    The purpose of this study was to evaluate the relationship between technical performance and patient outcomes in laparoscopic gastric cancer surgery. Laparoscopic gastrectomy for cancer is an advanced procedure with high rate of postoperative morbidity and mortality. Many variables including patient, disease, and perioperative management factors have been shown to impact postoperative outcomes; however, the role of surgical performance is insufficiently investigated. A retrospective review was performed for all patients who had undergone laparoscopic gastrectomy for cancer at 3 teaching institutions between 2009 and 2015. Patients with available, unedited video-recording of their procedure were included in the study. Video files were rated for technical performance, using Objective Structured Assessments of Technical Skills (OSATS) and Generic Error Rating Tool instruments. The main outcome variable was major short-term complications. The effect of technical performance on patient outcomes was assessed using logistic regression analysis with backward selection strategy. Sixty-one patients with available video recordings were included in the study. The overall complication rate was 29.5%. The mean Charlson comorbidity index, type of procedure, and the global OSATS score were included in the final predictive model. Lower performance score (OSATS ≤29) remained an independent predictor for major short-term outcomes (odds ratio 6.49), while adjusting for comorbidities and type of procedure. Intraoperative technical performance predicts major short-term outcomes in laparoscopic gastrectomy for cancer. Ongoing assessment and enhancement of surgical skills using modern, evidence-based strategies might improve short-term patient outcomes. Future work should focus on developing and studying the effectiveness of such interventions in laparoscopic gastric cancer surgery.

  2. Orthogonal Higher Order Structure of the WISC-IV Spanish Using Hierarchical Exploratory Factor Analytic Procedures

    ERIC Educational Resources Information Center

    McGill, Ryan J.; Canivez, Gary L.

    2016-01-01

    As recommended by Carroll, the present study examined the factor structure of the Wechsler Intelligence Scale for Children-Fourth Edition Spanish (WISC-IV Spanish) normative sample using higher order exploratory factor analytic techniques not included in the WISC-IV Spanish Technical Manual. Results indicated that the WISC-IV Spanish subtests were…

  3. Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy.

    PubMed

    Jones, A Kyle; Pasciak, Alexander S; Wagner, Louis K

    2016-07-01

    To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (Eavg) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

  4. Exploratory Bifactor Analysis of the WJ-III Cognitive in Adulthood via the Schmid-Leiman Procedure

    ERIC Educational Resources Information Center

    Dombrowski, Stefan C.

    2014-01-01

    The Woodcock-Johnson-III cognitive in the adult time period (age 20 to 90 plus) was analyzed using exploratory bifactor analysis via the Schmid-Leiman orthogonalization procedure. The results of this study suggested possible overfactoring, a different factor structure from that posited in the Technical Manual and a lack of invariance across both…

  5. Technical aspects of a demonstration tape for three-dimensional sound displays

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Wenzel, Elizabeth M.

    1990-01-01

    This document was developed to accompany an audio cassette that demonstrates work in three-dimensional auditory displays, developed at the Ames Research Center Aerospace Human Factors Division. It provides a text version of the audio material, and covers the theoretical and technical issues of spatial auditory displays in greater depth than on the cassette. The technical procedures used in the production of the audio demonstration are documented, including the methods for simulating rotorcraft radio communication, synthesizing auditory icons, and using the Convolvotron, a real-time spatialization device.

  6. Patient-specific rehearsal prior to EVAR: a pilot study.

    PubMed

    Desender, L; Rancic, Z; Aggarwal, R; Duchateau, J; Glenck, M; Lachat, M; Vermassen, F; Van Herzeele, I

    2013-06-01

    This study aims to evaluate feasibility, face validity, influence on technical factors and subjective sense of utility of patient-specific rehearsal (PsR) prior to endovascular aortic aneurysm repair (EVAR). A prospective, multicentre pilot study. Patients suitable for EVAR were enrolled and a three-dimensional (3D) model of the patient's anatomy was generated. Less than 24 h prior to the real case, rehearsals were conducted in the laboratory or clinical angiosuite. Technical metrics were recorded during both procedures. A subjective questionnaire was used to evaluate realism, technical and human factor aspects (scale 1-5). Ten patients were enrolled. In one case, the treatment plan was altered based on PsR. In 7/9 patients, the rehearsal significantly altered the optimal C-arm position for the proximal landing zone and an identical fluoroscopy angle was chosen in the real procedure. All team members found the rehearsal useful for selecting the optimal fluoroscopy angle (median 4). The realism of the EVAR procedure simulation was rated highly (median 4). All team members found the PsR useful to prepare the individual team members and the entire team (median 4). PsR for EVAR permits creation of realistic case studies. Subjective evaluation indicates that it may influence optimal C-arm angles and be valuable to prepare the entire team. A randomised controlled trial (RCT) is planned to evaluate how this technology may influence technical and team performance, ultimately leading to improved patient safety. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Nighttime kidney transplantation is associated with less pure technical graft failure.

    PubMed

    Brunschot, Denise M D Özdemir-van; Hoitsma, Andries J; van der Jagt, Michel F P; d'Ancona, Frank C; Donders, Rogier A R T; van Laarhoven, Cees J H M; Hilbrands, Luuk B; Warlé, Michiel C

    2016-07-01

    To minimize cold ischemia time, transplantations with kidneys from deceased donors are frequently performed during the night. However, sleep deprivation of those who perform the transplantation may have adverse effects on cognitive and psychomotor performance and may cause reduced cognitive flexibility. We hypothesize that renal transplantations performed during the night are associated with an increased incidence of pure technical graft failure. A retrospective analysis of data of the Dutch Organ Transplant Registry concerning all transplants from deceased donors between 2000 and 2013 was performed. Nighttime surgery was defined as the start of the procedure between 8 p.m. and 8 a.m. The primary outcome measure was technical graft failure, defined as graft loss within 10 days after surgery without signs of (hyper)acute rejection. Of 4.519 renal transplantations in adult recipients, 1.480 were performed during the night. The incidence of pure technical graft failure was 1.0 % for procedures started during the night versus 2.6 % for daytime surgery (p = .001). In a multivariable model, correcting for relevant donor, recipient and graft factors, daytime surgery was an independent predictor of pure technical graft failure (p < .001). Limitation of this study is mainly to its retrospective design, and the influence of some relevant variables, such as the experience level of the surgeon, could not be assessed. We conclude that nighttime surgery is associated with less pure technical graft failures. Further research is required to explore factors that may positively influence the performance of the surgical team during the night.

  8. The socio-technical organisation of community pharmacies as a factor in the Electronic Prescription Service Release Two implementation: a qualitative study

    PubMed Central

    2012-01-01

    Background The introduction of a new method of transmitting prescriptions from general practices to community pharmacies in England (Electronic Prescription Service Release 2 (EPS2)) has generated debate on how it will change work practice. As EPS2 will be a key technical element in dispensing, we reviewed the literature to find that there were no studies on how social and technical elements come together to form work practice in community pharmacies. This means the debate has little point of reference. Our aim therefore was to study the ways social and technical elements of a community pharmacy are used to achieve dispensing through the development of a conceptual model on pharmacy work practice, and to consider how a core technical element such the EPS2 could change work practice. Method We used ethnographic methods inclusive of case-study observations and interviews to collect qualitative data from 15 community pharmacies that were in the process of adopting or were soon to adopt EPS2. We analysed the case studies thematically and used rigorous multi-dimensional and multi-disciplinary interpretive validation techniques to cross analyse findings. Results In practice, dispensing procedures were not designed to take into account variations in human and technical integration, and assumed that repetitive and collective use of socio-technical elements were at a constant. Variables such as availability of social and technical resources, and technical know-how of staff were not taken into account in formalised procedures. Yet community pharmacies were found to adapt their dispensing in relation to the balance of social and technical elements available, and how much of the social and technical elements they were willing to integrate into dispensing. While some integrated as few technical elements as possible, some depended entirely on technical artefacts. This pattern also applied to the social elements of dispensing. Through the conceptual model development process, we identified three approaches community pharmacies used to appropriate procedures in practice. These were ‘technically oriented’, ‘improvising’ or ‘socially oriented’. Conclusion We offer a model of different work approaches community pharmacies use to dispense, which suggests that when adopting a core technical element such as the EPS2 system of dispensing there could be variations in its successful adoption. Technically oriented pharmacies might find it easiest to integrate a similar artefact into work practice although needs EPS2 to synchronise effectively with existing technologies. Pharmacies adopting an improvising-approach have the potential to improve how they organise dispensing through EPS2 although they will need to improve how they apply their operating procedures. Socially oriented pharmacies will need to dramatically adapt their approach to dispensing since they usually rely on few technical tools. PMID:23256484

  9. The socio-technical organisation of community pharmacies as a factor in the Electronic Prescription Service Release Two implementation: a qualitative study.

    PubMed

    Harvey, Jasmine; Avery, Anthony J; Waring, Justin; Barber, Nick

    2012-12-20

    The introduction of a new method of transmitting prescriptions from general practices to community pharmacies in England (Electronic Prescription Service Release 2 (EPS2)) has generated debate on how it will change work practice. As EPS2 will be a key technical element in dispensing, we reviewed the literature to find that there were no studies on how social and technical elements come together to form work practice in community pharmacies. This means the debate has little point of reference. Our aim therefore was to study the ways social and technical elements of a community pharmacy are used to achieve dispensing through the development of a conceptual model on pharmacy work practice, and to consider how a core technical element such the EPS2 could change work practice. We used ethnographic methods inclusive of case-study observations and interviews to collect qualitative data from 15 community pharmacies that were in the process of adopting or were soon to adopt EPS2. We analysed the case studies thematically and used rigorous multi-dimensional and multi-disciplinary interpretive validation techniques to cross analyse findings. In practice, dispensing procedures were not designed to take into account variations in human and technical integration, and assumed that repetitive and collective use of socio-technical elements were at a constant. Variables such as availability of social and technical resources, and technical know-how of staff were not taken into account in formalised procedures. Yet community pharmacies were found to adapt their dispensing in relation to the balance of social and technical elements available, and how much of the social and technical elements they were willing to integrate into dispensing. While some integrated as few technical elements as possible, some depended entirely on technical artefacts. This pattern also applied to the social elements of dispensing. Through the conceptual model development process, we identified three approaches community pharmacies used to appropriate procedures in practice. These were 'technically oriented', 'improvising' or 'socially oriented'. We offer a model of different work approaches community pharmacies use to dispense, which suggests that when adopting a core technical element such as the EPS2 system of dispensing there could be variations in its successful adoption. Technically oriented pharmacies might find it easiest to integrate a similar artefact into work practice although needs EPS2 to synchronise effectively with existing technologies. Pharmacies adopting an improvising-approach have the potential to improve how they organise dispensing through EPS2 although they will need to improve how they apply their operating procedures. Socially oriented pharmacies will need to dramatically adapt their approach to dispensing since they usually rely on few technical tools.

  10. Factors that influence the non-technical skills performance of scrub nurses: a prospective study.

    PubMed

    Kang, Evelyn; Massey, Debbie; Gillespie, Brigid M

    2015-12-01

    To identify and describe the factors that impact on the performance of scrub nurses' non-technical skills performance during the intra-operative phase of surgery. Non-technical skills have been identified as important precursors to errors in the operating room. However, few studies have investigated factors influencing non-technical skills of scrub nurses. Prospective observational study. Structured observations were performed on a sample of 182 surgical procedures across eight specialities by two trained observers from August 2012-April 2013 at two hospital sites. Participants were purposively selected scrub nurses. Bivariate correlations and a multiple linear regression model were used to identify associations among length of surgery, patients' acuity using the American Society of Anesthesiologists classification system, team familiarity, number of occasions scout nurses leave the operating room, change of scout nurse and the outcome, the non-technical skills performance of scrub nurses. Patient acuity and team familiarity were the strongest predictors of scrub nurses' non-technical skills performance at hospital site A. There were no correlations between the predictors and the performance of scrub nurses at hospital site B. A dedicated surgical team and patient acuity potentially influence the performance of scrub nurses' non-technical skills. Familiarity with team members foster advanced planning, thus minimizing distractions and interruptions that impact on scrub nurses' performance. Development of interventions aimed at improving non-technical skills has the potential to make a substantial difference and enhance patient care. © 2015 John Wiley & Sons Ltd.

  11. A Procedural Skills OSCE: Assessing Technical and Non-Technical Skills of Internal Medicine Residents

    ERIC Educational Resources Information Center

    Pugh, Debra; Hamstra, Stanley J.; Wood, Timothy J.; Humphrey-Murto, Susan; Touchie, Claire; Yudkowsky, Rachel; Bordage, Georges

    2015-01-01

    Internists are required to perform a number of procedures that require mastery of technical and non-technical skills, however, formal assessment of these skills is often lacking. The purpose of this study was to develop, implement, and gather validity evidence for a procedural skills objective structured clinical examination (PS-OSCE) for internal…

  12. The Vendors' Corner--The Request for Proposal.

    ERIC Educational Resources Information Center

    Sugnet, Chris; And Others

    1987-01-01

    Several online vendors address the issue of RFPs (requests for proposals) for library systems, discussing the documents' style, technical standards, library expectations, liabilities associated with using this procedure, factors in the decision to bid, and the need for a standardized document and national clearinghouse. (CLB)

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org

    Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according tomore » measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A; Pasciak, A; Wagner, L

    Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluationsmore » studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.« less

  15. A procedural skills OSCE: assessing technical and non-technical skills of internal medicine residents.

    PubMed

    Pugh, Debra; Hamstra, Stanley J; Wood, Timothy J; Humphrey-Murto, Susan; Touchie, Claire; Yudkowsky, Rachel; Bordage, Georges

    2015-03-01

    Internists are required to perform a number of procedures that require mastery of technical and non-technical skills, however, formal assessment of these skills is often lacking. The purpose of this study was to develop, implement, and gather validity evidence for a procedural skills objective structured clinical examination (PS-OSCE) for internal medicine (IM) residents to assess their technical and non-technical skills when performing procedures. Thirty-five first to third-year IM residents participated in a 5-station PS-OSCE, which combined partial task models, standardized patients, and allied health professionals. Formal blueprinting was performed and content experts were used to develop the cases and rating instruments. Examiners underwent a frame-of-reference training session to prepare them for their rater role. Scores were compared by levels of training, experience, and to evaluation data from a non-procedural OSCE (IM-OSCE). Reliability was calculated using Generalizability analyses. Reliabilities for the technical and non-technical scores were 0.68 and 0.76, respectively. Third-year residents scored significantly higher than first-year residents on the technical (73.5 vs. 62.2%) and non-technical (83.2 vs. 75.1%) components of the PS-OSCE (p < 0.05). Residents who had performed the procedures more frequently scored higher on three of the five stations (p < 0.05). There was a moderate disattenuated correlation (r = 0.77) between the IM-OSCE and the technical component of the PS-OSCE scores. The PS-OSCE is a feasible method for assessing multiple competencies related to performing procedures and this study provides validity evidence to support its use as an in-training examination.

  16. 32 CFR 250.5 - Procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.5 Procedures. All determinations to disseminate or withhold technical data subject to this part shall be consistent both with the policies set forth in § 250.4 of this part, and with the following procedures: (a) Requests for technical data shall be...

  17. Groundwater technical procedures of the U.S. Geological Survey

    USGS Publications Warehouse

    Cunningham, William L.; Schalk, Charles W.

    2011-01-01

    A series of groundwater technical procedures documents (GWPDs) has been released by the U.S. Geological Survey, Water-Resources Discipline, for general use by the public. These technical procedures were written in response to the need for standardized technical procedures of many aspects of groundwater science, including site and measuring-point establishment, measurement of water levels, and measurement of well discharge. The techniques are described in the GWPDs in concise language and are accompanied by necessary figures and tables derived from cited manuals, reports, and other documents. Because a goal of this series of procedures is to remain current with the state of the science, and because procedures change over time, this report is released in an online format only. As new procedures are developed and released, they will be linked to this document.

  18. Intradural Procedural Time to Assess Technical Difficulty of Superciliary Keyhole and Pterional Approaches for Unruptured Middle Cerebral Artery Aneurysms

    PubMed Central

    Choi, Yeon-Ju; Son, Wonsoo; Park, Ki-Su

    2016-01-01

    Objective This study used the intradural procedural time to assess the overall technical difficulty involved in surgically clipping an unruptured middle cerebral artery (MCA) aneurysm via a pterional or superciliary approach. The clinical and radiological variables affecting the intradural procedural time were investigated, and the intradural procedural time compared between a superciliary keyhole approach and a pterional approach. Methods During a 5.5-year period, patients with a single MCA aneurysm were enrolled in this retrospective study. The selection criteria for a superciliary keyhole approach included : 1) maximum diameter of the unruptured MCA aneurysm <15 mm, 2) neck diameter of the MCA aneurysm <10 mm, and 3) aneurysm location involving the sphenoidal or horizontal segment of MCA (M1) segment and MCA bifurcation, excluding aneurysms distal to the MCA genu. Meanwhile, the control comparison group included patients with the same selection criteria as for a superciliary approach, yet who preferred a pterional approach to avoid a postoperative facial wound or due to preoperative skin trouble in the supraorbital area. To determine the variables affecting the intradural procedural time, a multiple regression analysis was performed using such data as the patient age and gender, maximum aneurysm diameter, aneurysm neck diameter, and length of the pre-aneurysm M1 segment. In addition, the intradural procedural times were compared between the superciliary and pterional patient groups, along with the other variables. Results A total of 160 patients underwent a superciliary (n=124) or pterional (n=36) approach for an unruptured MCA aneurysm. In the multiple regression analysis, an increase in the diameter of the aneurysm neck (p<0.001) was identified as a statistically significant factor increasing the intradural procedural time. A Pearson correlation analysis also showed a positive correlation (r=0.340) between the neck diameter and the intradural procedural time. When comparing the superciliary and pterional groups, no statistically significant between-group difference was found in terms of the intradural procedural time reflecting the technical difficulty (mean±standard deviation : 29.8±13.0 min versus 27.7±9.6 min). Conclusion A superciliary keyhole approach can be a useful alternative to a pterional approach for an unruptured MCA aneurysm with a maximum diameter <15 mm and neck diameter <10 mm, representing no more of a technical challenge. For both surgical approaches, the technical difficulty increases along with the neck diameter of the MCA aneurysm. PMID:27847568

  19. Effects of a Velocity-Vector Based Command Augmentation System and Synthetic Vision System Terrain Portrayal and Guidance Symbology Concepts on Single-Pilot Performance

    NASA Technical Reports Server (NTRS)

    Liu, Dahai; Goodrich, Kenneth H.; Peak, Bob

    2010-01-01

    This study investigated the effects of synthetic vision system (SVS) concepts and advanced flight controls on the performance of pilots flying a light, single-engine general aviation airplane. We evaluated the effects and interactions of two levels of terrain portrayal, guidance symbology, and flight control response type on pilot performance during the conduct of a relatively complex instrument approach procedure. The terrain and guidance presentations were evaluated as elements of an integrated primary flight display system. The approach procedure used in the study included a steeply descending, curved segment as might be encountered in emerging, required navigation performance (RNP) based procedures. Pilot performance measures consisted of flight technical performance, perceived workload, perceived situational awareness and subjective preference. The results revealed that an elevation based generic terrain portrayal significantly improved perceived situation awareness without adversely affecting flight technical performance or workload. Other factors (pilot instrument rating, control response type, and guidance symbology) were not found to significantly affect the performance measures.

  20. Writing a technical note.

    PubMed

    Ng, K H; Peh, W C G

    2010-02-01

    A technical note is a short article giving a brief description of a specific development, technique or procedure, or it may describe a modification of an existing technique, procedure or device applicable to medicine. The technique, procedure or device described should have practical value and should contribute to clinical diagnosis or management. It could also present a software tool, or an experimental or computational method. Technical notes are variously referred to as technical innovations or technical developments. The main criteria for publication will be the novelty of concepts involved, the validity of the technique and its potential for clinical applications.

  1. The Aortic Bifurcation Angle as a Factor in Application of the Outback for Femoropopliteal Lesions in Ipsilateral Versus Contralateral Approaches.

    PubMed

    Raskin, Daniel; Khaitovich, Boris; Balan, Shmuel; Silverberg, Daniel; Halak, Moshe; Rimon, Uri

    2018-01-01

    To assess the technical success of the Outback reentry device in contralateral versus ipsilateral approaches for femoropopliteal arterial occlusion. A retrospective review of patients treated for critical limb ischemia (CLI) using the Outback between January 2013 and July 2016 was performed. Age, gender, length and site of the occlusion, approach site, aortic bifurcation angle, and reentry site were recorded. Calcification score was assigned at both aortic bifurcation and reentry site. Technical success was assessed. During the study period, a total of 1300 endovascular procedures were performed on 489 patients for CLI. The Outback was applied on 50 femoropopliteal chronic total occlusions. Thirty-nine contralateral and 11 ipsilateral antegrade femoral were accessed. The device was used successfully in 41 patients (82%). There were nine failures, all in the contralateral approach group. Six due to inability to deliver the device due to acute aortic bifurcation angle and three due to failure to achieve luminal reentry. Procedural success was significantly affected by the aortic bifurcation angle (p = 0.013). The Outback has high technical success rates in treatment of femoropopliteal occlusion, when applied from either an ipsi- or contralateral approach. When applied in contralateral access, acute aortic bifurcation angle predicts procedural failure.

  2. Controversy of hand-assisted laparoscopic colorectal surgery

    PubMed Central

    Meshikhes, Abdul-Wahed Nasir

    2010-01-01

    Laparoscopically assisted colorectal procedures are time-consuming and technically demanding and hence have a long steep learning curve. In the technical demand, surgeons need to handle a long mobile organ, the colon, and have to operate on multiple abdominal quadrants, most of the time with the need to secure multiple mesenteric vessels. Therefore, a new surgical innovation called hand-assisted laparoscopic surgery (HALS) was introduced in the mid 1990s as a useful alternative to totally laparoscopic procedures. This hybrid operation allows the surgeon to introduce the non-dominant hand into the abdominal cavity through a special hand port while maintaining the pneumoperitoneum. A hand in the abdomen can restore the tactile sensation which is usually lacking in laparoscopic procedures. It also improves the eye-to-hand coordination, allows the hand to be used for blunt dissection or retraction and also permits rapid control of unexpected bleeding. All of those factors can contribute tremendously to reducing the operative time. Moreover, this procedure is also considered as a hybrid procedure that combines the advantages of both minimally invasive and conventional open surgery. Nevertheless, the exact role of HALS in colorectal surgery has not been well defined during the advanced totally laparoscopic procedures. This article reviews the current status of hand-assisted laparoscopic colorectal surgery as a minimally invasive procedure in the era of laparoscopic surgery. PMID:21128315

  3. Performance and capacity assessment of reinforced concrete bridge piers considering the current load and resistance factor design provisions and plastic hinge length in Kansas : [technical summary].

    DOT National Transportation Integrated Search

    2014-05-01

    Kansas Department of Transportation (KDOT) has implemented the new AASHTO : LRFD provisions in the state specific LRFD design procedure (KDOT-LRFD). There : have been some significant updates in new version of AASHTO-LRFD (2010), compared : to previo...

  4. A Big Data Analytics Methodology Program in the Health Sector

    ERIC Educational Resources Information Center

    Lawler, James; Joseph, Anthony; Howell-Barber, H.

    2016-01-01

    The benefits of Big Data Analytics are cited frequently in the literature. However, the difficulties of implementing Big Data Analytics can limit the number of organizational projects. In this study, the authors evaluate business, procedural and technical factors in the implementation of Big Data Analytics, applying a methodology program. Focusing…

  5. Measuring the Utility of a Basic French Vocabulary.

    ERIC Educational Resources Information Center

    Savard, Jean-Guy; Richards, Jack C.

    Using frequency, range, availability, and coverage as objectively weighted indices of utility in the development of a basic French vocabulary list, the authors describe the technical procedure used in this study and list the resultant first 153 words according to the four indices and the utility rating. Weighting factors for each index, based on…

  6. New Mexico Standards Based Assessment (NMSBA) Technical Report: 2006 Spring Administration

    ERIC Educational Resources Information Center

    Griph, Gerald W.

    2006-01-01

    The purpose of the NMSBA technical report is to provide users and other interested parties with a general overview of and technical characteristics of the 2006 NMSBA. The 2006 technical report contains the following information: (1) Test development; (2) Scoring procedures; (3) Calibration, scaling, and equating procedures; (4) Standard setting;…

  7. 26 CFR 601.106 - Appeals functions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... obtain Appeals consideration in (1) all office interview or correspondence examination cases or (2) a... technical advice on any technical or procedural question that develops during the processing and... on any technical or procedural question arising in connection with a case described in subdivision (i...

  8. Human Factors Topics in Flight Simulation: An Annotated Bibliography

    DTIC Science & Technology

    1976-01-01

    and technical information; - Continuously stimulating advances in the aerospace sciences relevant to strengthening the common defence posture...Topics treated under cost effectiveness are effectiveness as a function of training procedures, physical stimulation versus psychological stimulation ...fidelity of physical stimulation . HUDDLESTON. H.F. and ROLFE, J.M. Behaviouralfactors influencing aircrew response in training and research simulators

  9. Hydrostatic collapse research in support of the Oman India gas pipeline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stark, P.R.; McKeehan, D.S.

    1995-12-01

    This paper provides a summary of the collapse test program conducted as part of the technical development for the Ultra Deep Oman to India Pipeline. The paper describes the motivation for conducting the collapse test program, outlines the test objectives and procedures, presents the results obtained, and draws conclusions on the factors affecting collapse resistance.

  10. Transapical aortic valve implantation – a rescue procedure for patients with aortic stenosis and “porcelain aorta”

    PubMed Central

    Czerwinska, Katarzyna; Orłowska-Baranowska, Ewa; Witkowski, Adam; Demkow, Marcin; Abramczuk, Elżbieta; Michałek, Piotr; Greszata, Lidia; Stoklosa, Patrycjusz; Kuśmierski, Krzysztof; Kowal, Jaroslaw; Stepinska, Janina

    2011-01-01

    Surgical aortic valve replacement (AVR) still remains the treatment of choice in symptomatic significant aortic stenosis (AS). Due to technical problems, extensive calcification of the ascending aorta (“porcelain aorta”) is an additional risk factor for surgery and transapical aortic valve implantation (TAAVI) is likely to be the only rescue procedure for this group of patients. We describe the case of an 81-year-old woman with severe AS and “porcelain aorta”, in whom the only available life-saving intervention was TAAVI. PMID:22295040

  11. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  12. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  13. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  14. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  15. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  16. The IAEA’s activities on radiation protection in interventional cardiology

    PubMed Central

    Rehani, MM

    2007-01-01

    The International Atomic Energy Agency (IAEA) under its mandate of developing and applying standards of radiation safety has initiated a number of activities in recent years on radiation protection in interventional cardiology. These activities are implemented through four mechanisms, namely training, providing information through the website, research projects and assistance to Member States through Technical Cooperation (TC) projects. Major international initiatives have been taken in the area of training where more than half a dozen regional training courses have been conducted for cardiologists from over 50 countries. Additionally four national training events for over 300 medical and paramedical staff members involved in interventional procedures were held. The training material is freely available on CD from the IAEA. The newly established website provides information on radiation protection issues [1]. Two coordinated research projects have just been completed where peak skin doses to patients undergoing high dose interventional procedures were studied and factors to manage patient doses were identified. The technical cooperation projects involving protection in cardiac interventional procedures have 30 countries as participants. PMID:21614275

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, Osman, E-mail: osman1423@gmail.com; Patel, Mikin V.; Masrani, Abdulrahman

    PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-relatedmore » complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.« less

  18. 48 CFR 227.7103-11 - Contractor procedures and records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Rights in Technical Data 227.7103-11 Contractor procedures and records. (a) The clause at 252.227-7013, Rights in Technical Data—Noncommercial Items, requires a contractor, and its subcontractors or suppliers that will deliver technical data with other than unlimited rights, to establish and follow written...

  19. Technical Operating Procedures for Resource Documentation Under the Oil Pollution Act of 1990

    DOT National Transportation Integrated Search

    1996-06-01

    Technical Operating Procedures (TOPs) for Resource Documentation under the Oil Pollution Act of 1990 (P.L.101-380) have been developed to provide guidance to users operating as, or in support of, the Federal On-Scene Coordinator(FOSC). The procedures...

  20. Simulation center training as a means to improve resident performance in percutaneous noncontinuous CT-guided fluoroscopic procedures with dose reduction.

    PubMed

    Mendiratta-Lala, Mishal; Williams, Todd R; Mendiratta, Vivek; Ahmed, Hafeez; Bonnett, John W

    2015-04-01

    The purpose of this study was to evaluate the effectiveness of a multifaceted simulation-based resident training for CT-guided fluoroscopic procedures by measuring procedural and technical skills, radiation dose, and procedure times before and after simulation training. A prospective analysis included 40 radiology residents and eight staff radiologists. Residents took an online pretest to assess baseline procedural knowledge. Second-through fourth-year residents' baseline technical skills with a procedural phantom were evaluated. First-through third-year residents then underwent formal didactic and simulation-based procedural and technical training with one of two interventional radiologists and followed the training with 1 month of supervised phantom-based practice. Thereafter, residents underwent final written and practical examinations. The practical examination included essential items from a 20-point checklist, including site and side marking, consent, time-out, and sterile technique along with a technical skills portion assessing pedal steps, radiation dose, needle redirects, and procedure time. The results indicated statistically significant improvement in procedural and technical skills after simulation training. For residents, the median number of pedal steps decreased by three (p=0.001), median dose decreased by 15.4 mGy (p<0.001), median procedure time decreased by 4.0 minutes (p<0.001), median number of needle redirects decreased by 1.0 (p=0.005), and median number of 20-point checklist items successfully completed increased by three (p<0.001). The results suggest that procedural skills can be acquired and improved by simulation-based training of residents, regardless of experience. CT simulation training decreases procedural time, decreases radiation dose, and improves resident efficiency and confidence, which may transfer to clinical practice with improved patient care and safety.

  1. Underappreciated Factors to Consider in Revision Anterior Cruciate Ligament Reconstruction: A Current Concepts Review

    PubMed Central

    Southam, Brendan R.; Colosimo, Angelo J.; Grawe, Brian

    2018-01-01

    Primary anterior cruciate ligament (ACL) reconstructions (ACLRs) are being performed with increasing frequency. While many of these will have successful outcomes, failures will occur in a subset of patients who will require revision ACLRs. As such, the number of revision procedures will continue to rise as well. While many reviews have focused on factors that commonly contribute to failure of primary ACLR, including graft choice, patient factors, early return to sport, and technical errors, this review focused on several factors that have received less attention in the literature. These include posterior tibial slope, varus malalignment, injury to the anterolateral ligament, and meniscal injury or deficiency. This review also appraised several emerging techniques that may be useful in the context of revision ACL surgery. While outcomes of revision ACLR are generally inferior to those of primary procedures, identifying these potentially underappreciated contributing factors preoperatively will allow the surgeon to address them at the time of revision, ideally improving patient outcomes and preventing recurrent ACL failure. PMID:29399591

  2. Surgeon and type of anesthesia predict variability in surgical procedure times.

    PubMed

    Strum, D P; Sampson, A R; May, J H; Vargas, L G

    2000-05-01

    Variability in surgical procedure times increases the cost of healthcare delivery by increasing both the underutilization and overutilization of expensive surgical resources. To reduce variability in surgical procedure times, we must identify and study its sources. Our data set consisted of all surgeries performed over a 7-yr period at a large teaching hospital, resulting in 46,322 surgical cases. To study factors associated with variability in surgical procedure times, data mining techniques were used to segment and focus the data so that the analyses would be both technically and intellectually feasible. The data were subdivided into 40 representative segments of manageable size and variability based on headers adopted from the common procedural terminology classification. Each data segment was then analyzed using a main-effects linear model to identify and quantify specific sources of variability in surgical procedure times. The single most important source of variability in surgical procedure times was surgeon effect. Type of anesthesia, age, gender, and American Society of Anesthesiologists risk class were additional sources of variability. Intrinsic case-specific variability, unexplained by any of the preceding factors, was found to be highest for shorter surgeries relative to longer procedures. Variability in procedure times among surgeons was a multiplicative function (proportionate to time) of surgical time and total procedure time, such that as procedure times increased, variability in surgeons' surgical time increased proportionately. Surgeon-specific variability should be considered when building scheduling heuristics for longer surgeries. Results concerning variability in surgical procedure times due to factors such as type of anesthesia, age, gender, and American Society of Anesthesiologists risk class may be extrapolated to scheduling in other institutions, although specifics on individual surgeons may not. This research identifies factors associated with variability in surgical procedure times, knowledge of which may ultimately be used to improve surgical scheduling and operating room utilization.

  3. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  4. 75 FR 16345 - Administrative Practices and Procedures; Good Guidance Practices; Technical Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-01

    .... FDA-1999-N-3539] (formerly Docket No. 1999N-4783) Administrative Practices and Procedures; Good Guidance Practices; Technical Amendment AGENCY: Food and Drug Administration, HHS. ACTION: Final rule... Subjects in 21 CFR Part 10 Administrative practice and procedure, News media. 0 Therefore, under the...

  5. Portal Vein Embolization: State-of-the-Art Technique and Options to Improve Liver Hypertrophy.

    PubMed

    Huang, Steven Y; Aloia, Thomas A

    2017-12-01

    Portal vein embolization (PVE) is associated with a high technical and clinical success rate for induction of future liver remnant hypertrophy prior to surgical resection. The degree of hypertrophy is variable and depends on multiple factors, including technical aspects of the procedure and underlying chronic liver disease. For patients with insufficient liver volume following PVE, adjunctive techniques, such as intra-portal administration of stem cells, dietary supplementation, transarterial embolization, and hepatic vein embolization, are available. Our purpose is to review the state-of-the-art technique associated with high-quality PVE and to discuss options to improve hypertrophy of the future liver remnant.

  6. Management of the athlete with a failed shoulder instability procedure.

    PubMed

    Gwathmey, F Winston; Warner, Jon J P

    2013-10-01

    The athlete with a failed instability procedure requires a thoughtful and systematic approach to achieve a good outcome. Goals of treatment should be defined and realistic expectations should be set. Revision stabilization has a high rate of recurrent instability, low rates of return to play, and low clinical outcome scores. Fundamental to successful revision surgery is choosing the correct procedure. The decision is straightforward in athletes with clear factors that predict recurrence (significant glenoid bone loss, engaging Hill-Sachs lesions) because only a bony procedure can restore the articular arc of the glenoid. Arthroscopic revision Bankart repair may be appropriate in those athletes who have an obvious Bankart tear and no bone loss after a traumatic reinjury. The challenge for the shoulder surgeon is identifying the best surgery for the athlete who does not have such clear-cut indications. Each factor that has the potential to lead to a poor outcome needs to be collected and calculated. Patient factors (age, laxity, type and level of sport), injury factors (mechanism of injury, capsulolabral injury, glenoid bone loss, Hill-Sachs lesion), and technical factors (previous surgery performed, integrity of repair, scarring) must be integrated into the treatment algorithm. Based on this collection of factors, the shoulder surgeon should be prepared to provide the athlete with the surgery that provides the best chance to return to playing sports and the lowest risk of recurrent instability. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Bayesian hypothesis testing for human threat conditioning research: an introduction and the condir R package

    PubMed Central

    Krypotos, Angelos-Miltiadis; Klugkist, Irene; Engelhard, Iris M.

    2017-01-01

    ABSTRACT Threat conditioning procedures have allowed the experimental investigation of the pathogenesis of Post-Traumatic Stress Disorder. The findings of these procedures have also provided stable foundations for the development of relevant intervention programs (e.g. exposure therapy). Statistical inference of threat conditioning procedures is commonly based on p-values and Null Hypothesis Significance Testing (NHST). Nowadays, however, there is a growing concern about this statistical approach, as many scientists point to the various limitations of p-values and NHST. As an alternative, the use of Bayes factors and Bayesian hypothesis testing has been suggested. In this article, we apply this statistical approach to threat conditioning data. In order to enable the easy computation of Bayes factors for threat conditioning data we present a new R package named condir, which can be used either via the R console or via a Shiny application. This article provides both a non-technical introduction to Bayesian analysis for researchers using the threat conditioning paradigm, and the necessary tools for computing Bayes factors easily. PMID:29038683

  8. Minimum-complexity helicopter simulation math model

    NASA Technical Reports Server (NTRS)

    Heffley, Robert K.; Mnich, Marc A.

    1988-01-01

    An example of a minimal complexity simulation helicopter math model is presented. Motivating factors are the computational delays, cost, and inflexibility of the very sophisticated math models now in common use. A helicopter model form is given which addresses each of these factors and provides better engineering understanding of the specific handling qualities features which are apparent to the simulator pilot. The technical approach begins with specification of features which are to be modeled, followed by a build up of individual vehicle components and definition of equations. Model matching and estimation procedures are given which enable the modeling of specific helicopters from basic data sources such as flight manuals. Checkout procedures are given which provide for total model validation. A number of possible model extensions and refinement are discussed. Math model computer programs are defined and listed.

  9. Impact of the BALLOTS Shared Cataloging System on the Amount of Change in the Library Technical Processing Department.

    ERIC Educational Resources Information Center

    Kershner, Lois M.

    The amount of change resulting from the implementation of the Bibliographic Automation of Large Library Operations using a Time-sharing System (BALLOTS) is analyzed, in terms of (1) physical room arrangement, (2) work procedure, and (3) organizational structure. Also considered is the factor of amount of time the new system has been in use.…

  10. Skin prick tests and allergy diagnosis.

    PubMed

    Antunes, João; Borrego, Luís; Romeira, Ana; Pinto, Paula

    2009-01-01

    Skin testing remains an essential diagnostic tool in modern allergy practice. A significant variability has been reported regarding technical procedures, interpretation of results and documentation. This review has the aim of consolidating methodological recommendations through a critical analysis on past and recent data. This will allow a better understanding on skin prick test (SPT) history; technique; (contra-) indications; interpretation of results; diagnostic pitfalls; adverse reactions; and variability factors.

  11. Carotid artery stenting in patients with symptomatic carotid stenosis: a single-center series.

    PubMed

    Kessler, I; Gory, B; Macian, F; Nakiri, G; Al-Khawaldeh, M; Riva, R; Boncoeur, M P; Mounayer, C

    2013-03-01

    Carotid angioplasty with stenting (CAS) in patients with carotid stenosis (CS) has become more restricted in France especially since the disclosure of such studies as EVA-3S and Stent-supported percutaneous angioplasty of the carotid artery versus endarterectomy (SPACE). This report is of a series of CS cases contraindicated for endarterectomy that underwent CAS at a French center of interventional neuroradiology. Fifty-five patients with symptomatic CS more than 60% consecutively submitted to CAS between September 2008 and February 2011. The primary endpoint was either death or stroke within 30 days of the procedure; a secondary goal was to identify any possible factors that might have influenced the success and outcome of the intervention. The overall periprocedural stroke/death rate at 30 days was 5.4% (three out of 55 patients), with three non-disabling strokes and no deaths. Twenty-seven patients (49.1%) were treated with a cerebral protection device (CPD). Stent placement was achieved in all cases. Open- and closed-cell stents were implanted in 40 (72.7%) and 15 procedures (27.3%), respectively. Neither the use of a CPD, the carotid stent cell design nor any anatomical or technical factors were associated with a lower risk of stroke or death within 30 days of CAS. CAS in symptomatic patients with CS contraindicated for endarterectomy in this selected French series proved feasible and safe, with acceptable levels of morbidity. Use of a CPD, type of stent (open- or closed-cell), and anatomical and technical factors had no influence on the success of the procedure or the outcome within 30 days of the operation. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  12. Catheter-based treatment of coronary artery disease: past, present, and future.

    PubMed

    Holmes, David R; Williams, David O

    2008-08-01

    September 2007 marked the 30-year anniversary of the first human percutaneous coronary intervention, an index event that changed the course of modern-day cardiovascular care. Before that first procedure, adult invasive cardiology focused on diagnostic angiography as well as hemodynamic assessment of structural heart disease. Since that initial procedure, percutaneous coronary intervention has become the most frequently performed coronary revascularization procedure worldwide. Several factors have been responsible for this dramatic paradigm shift, the most prominent being identification of opportunities for technical improvement and the application of innovation and investigation in concert with colleagues, professional societies, and industry. These approaches will continue to be of paramount importance as new technologies are brought to bear on an increasingly broader group of patients with cardiovascular disease.

  13. Evaluation and treatment of failed shoulder instability procedures.

    PubMed

    Ho, Anthony G; Gowda, Ashok L; Michael Wiater, J

    2016-09-01

    Management of the unstable shoulder after a failed stabilization procedure can be difficult and challenging. Detailed understanding of the native shoulder anatomy, including its static and dynamic restraints, is necessary for determining the patient's primary pathology. In addition, evaluation of the patient's history, physical exam, and imaging is important for identifying the cause for failure after the initial procedure. Common mistakes include under-appreciation of bony defects, failure to recognize capsular laxity, technical errors, and missed associated pathology. Many potential treatment options exist for revision surgery, including open or arthroscopic Bankart repair, bony augmentation procedures, and management of Hill Sachs defects. The aim of this narrative review is to discuss in-depth the common risk factors for post-surgical failure, components for appropriate evaluation, and the different surgical options available for revision stabilization. Level of evidence Level V.

  14. [Using an employee survey as a means of quality assurance in newborn hearing screening].

    PubMed

    Depenbrock, A; Matulat, P; am Zehnhoff-Dinnesen, A

    2013-03-01

    Studies drawing information not only from technical data but also from surveying human resources behind the universal newborn hearing screening (UNHS) appear to be a rarity. This study aims at showing how the state of both knowledge and practical skills among the screening staff are essential aspects in future quality management. A self-developed questionnaire was sent to hospital staff addressing a total of 710 nurses who were registered as having undertaken a UNHS training course. Questions were aimed at aspects of organization, personal practical skills, current problems and improvement possibilities. High rates of occupancy, lack of trained personnel, technical issues and background noise disturbances were considered to be factors that increased time pressure and slowed down procedures. Of the participants 16 % considered communicating a "refer" result to parents a difficult step and 8 % felt insecure when explaining the aims and procedures to parents. There was a high interest in further training sessions. This survey served well to reveal aspects of improvement in screening procedures and meeting staff needs. The training sessions should outline practical aspects of conducting screening and also professional, sensitive communication to parents.

  15. AgRISTARS: Foreign Commodity production forecasting. Project procedures designation and description document, volume 1

    NASA Technical Reports Server (NTRS)

    Waggoner, J. T.; Phinney, D. E. (Principal Investigator)

    1981-01-01

    The crop estimation analysis procedures documentation of the AgRISTARS - Foreign Commodity Production Forecasting Project (FCPF) is presented. Specifically it includes the technical/management documentation of the remote sensing data analysis procedures prepared in accordance with the guidelines provided in the FCPF communication/documentation standards manual. Standard documentation sets are given arranged by procedural type and level then by crop types or other technically differentiating categories.

  16. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    PubMed

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-06-01

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  17. A visual graphic/haptic rendering model for hysteroscopic procedures.

    PubMed

    Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer

    2006-03-01

    Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilises an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organised curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynaecologic endoscopy training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopy factors, current training and accreditation, and proposes a hysteroscopic simulator design that is suitable for educating and training.

  18. Is the learning curve endless? One surgeon's experience with robotic prostatectomy

    NASA Astrophysics Data System (ADS)

    Patel, Vipul; Thaly, Rahul; Shah, Ketul

    2007-02-01

    Introduction: After performing 1,000 robotic prostatectomies we reflected back on our experience to determine what defined the learning curve and the essential elements that were the keys to surmounting it. Method: We retrospectively assessed our experience to attempt to define the learning curve(s), key elements of the procedure, technical refinements and changes in technology that facilitated our progress. Result: The initial learning curve to achieve basic competence and the ability to smoothly perform the procedure in less than 4 hours with acceptable outcomes was approximately 25 cases. A second learning curve was present between 75-100 cases as we approached more complicated patients. At 200 cases we were comfortably able to complete the procedure routinely in less than 2.5 hours with no specific step of the procedure hindering our progression. At 500 cases we had the introduction of new instrumentation (4th arm, biopolar Maryland, monopolar scissors) that changed our approach to the bladder neck and neurovascular bundle dissection. The most challenging part of the procedure was the bladder neck dissection. Conclusion: There is no single parameter that can be used to assess or define the learning curve. We used a combination of factors to make our subjective definition this included: operative time, smoothness of technical progression during the case along with clinical outcomes. The further our case experience progressed the more we expected of our outcomes, thus we continually modified our technique and hence embarked upon yet a new learning curve.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful;more » in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.« less

  20. Financial auditing at enterprises for control of projects realized with credit fund-raising

    NASA Astrophysics Data System (ADS)

    Lukmanova, Inessa

    2017-10-01

    The article analyzes methods of conducting financial audit under the construction control of projects implemented with raising credit funds in modern conditions. This work aims to improve the methodological toolkit of construction control when lending projects of the construction of transport infrastructure. The paper considers correlations of various procedures of construction control, financial audit and organizational and technical factors affecting investment and construction projects. The authors presented the logical scheme of the process of lending to legal entities and developed an algorithm of the procedure for conducting a financial audit, allowing to make possible adjustments and the right decision.

  1. Developing technical expertise in emergency medicine--the role of simulation in procedural skill acquisition.

    PubMed

    Wang, Ernest E; Quinones, Joshua; Fitch, Michael T; Dooley-Hash, Suzanne; Griswold-Theodorson, Sharon; Medzon, Ron; Korley, Frederick; Laack, Torrey; Robinett, Adam; Clay, Lamont

    2008-11-01

    Developing technical expertise in medical procedures is an integral component of emergency medicine (EM) practice and training. This article is the work of an expert panel composed of members from the Society for Academic Emergency Medicine (SAEM) Interest Group, the SAEM Technology in Medical Education Committee, and opinions derived from the May 2008 Academic Emergency Medicine Consensus Conference, "The Science of Simulation in Healthcare." The writing group reviewed the simulation literature on procedures germane to EM training, virtual reality training, and instructional learning theory as it pertains to skill acquisition and procedural skills decay. The authors discuss the role of simulation in teaching technical expertise, identify training conditions that lead to effective learning, and provide recommendations for future foci of research.

  2. Cardiovascular Surgery Residency Program: Training Coronary Anastomosis Using the Arroyo Simulator and UNIFESP Models.

    PubMed

    Maluf, Miguel Angel; Gomes, Walter José; Bras, Ademir Massarico; Araújo, Thiago Cavalcante Vila Nova de; Mota, André Lupp; Cardoso, Caio Cesar; Coutinho, Rafael Viana dos S

    2015-01-01

    Engage the UNIFESP Cardiovascular Surgery residents in coronary anastomosis, assess their skills and certify results, using the Arroyo Anastomosis Simulator and UNIFESP surgical models. First to 6th year residents attended a weekly program of technical training in coronary anastomosis, using 4 simulation models: 1. Arroyo simulator; 2. Dummy with a plastic heart; 3. Dummy with a bovine heart; and 4. Dummy with a beating pig heart. The assessment test was comprised of 10 items, using a scale from 1 to 5 points in each of them, creating a global score of 50 points maximum. The technical performance of the candidate showed improvement in all items, especially manual skill and technical progress, critical sense of the work performed, confidence in the procedure and reduction of the time needed to perform the anastomosis after 12 weeks practice. In response to the multiplicity of factors that currently influence the cardiovascular surgeon training, there have been combined efforts to reform the practices of surgical medical training. 1 - The four models of simulators offer a considerable contribution to the field of cardiovascular surgery, improving the skill and dexterity of the surgeon in training. 2 - Residents have shown interest in training and cooperate in the development of innovative procedures for surgical medical training in the art.

  3. Cardiovascular Surgery Residency Program: Training Coronary Anastomosis Using the Arroyo Simulator and UNIFESP Models

    PubMed Central

    Maluf, Miguel Angel; Gomes, Walter José; Bras, Ademir Massarico; de Araújo, Thiago Cavalcante Vila Nova; Mota, André Lupp; Cardoso, Caio Cesar; Coutinho, Rafael Viana dos S.

    2015-01-01

    OBJECTIVE Engage the UNIFESP Cardiovascular Surgery residents in coronary anastomosis, assess their skills and certify results, using the Arroyo Anastomosis Simulator and UNIFESP surgical models. METHODS First to 6th year residents attended a weekly program of technical training in coronary anastomosis, using 4 simulation models: 1. Arroyo simulator; 2. Dummy with a plastic heart; 3. Dummy with a bovine heart; and 4. Dummy with a beating pig heart. The assessment test was comprised of 10 items, using a scale from 1 to 5 points in each of them, creating a global score of 50 points maximum. RESULTS The technical performance of the candidate showed improvement in all items, especially manual skill and technical progress, critical sense of the work performed, confidence in the procedure and reduction of the time needed to perform the anastomosis after 12 weeks practice. In response to the multiplicity of factors that currently influence the cardiovascular surgeon training, there have been combined efforts to reform the practices of surgical medical training. CONCLUSION 1 - The four models of simulators offer a considerable contribution to the field of cardiovascular surgery, improving the skill and dexterity of the surgeon in training. 2 - Residents have shown interest in training and cooperate in the development of innovative procedures for surgical medical training in the art. PMID:26735604

  4. 42 CFR 493.1449 - Standard; Technical supervisor qualifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... service in which the laboratory performs high complexity tests or procedures. The director of a laboratory... may perform anatomic and clinical laboratory procedures and tests in all specialties and... tests in the subspecialty of bacteriology, the individual functioning as the technical supervisor must...

  5. Technical Operating Procedures for State Access Under the Oil Pollution Act of 1990

    DOT National Transportation Integrated Search

    1992-11-01

    Technical Operating Procedures (TOPs) to be used by the National Pollution Funds : Center (NPFC) to provide guidance to Federal On-Scene Coordinators (FOSCs) and : Coast Guard Districts concerning a State Governor's request for access to the : Oil Sp...

  6. 7 CFR 1775.31 - Authorization.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (CONTINUED) TECHNICAL ASSISTANCE GRANTS Technical Assistance and Training Grants § 1775.31 Authorization. This subpart sets forth additional policies and procedures for making Technical Assistance and Training...

  7. A National Needs Assessment to Identify Technical Procedures in Vascular Surgery for Simulation Based Training.

    PubMed

    Nayahangan, L J; Konge, L; Schroeder, T V; Paltved, C; Lindorff-Larsen, K G; Nielsen, B U; Eiberg, J P

    2017-04-01

    Practical skills training in vascular surgery is facing challenges because of an increased number of endovascular procedures and fewer open procedures, as well as a move away from the traditional principle of "learning by doing." This change has established simulation as a cornerstone in providing trainees with the necessary skills and competences. However, the development of simulation based programs often evolves based on available resources and equipment, reflecting convenience rather than a systematic educational plan. The objective of the present study was to perform a national needs assessment to identify the technical procedures that should be integrated in a simulation based curriculum. A national needs assessment using a Delphi process was initiated by engaging 33 predefined key persons in vascular surgery. Round 1 was a brainstorming phase to identify technical procedures that vascular surgeons should learn. Round 2 was a survey that used a needs assessment formula to explore the frequency of procedures, the number of surgeons performing each procedure, risk and/or discomfort, and feasibility for simulation based training. Round 3 involved elimination and ranking of procedures. The response rate for round 1 was 70%, with 36 procedures identified. Round 2 had a 76% response rate and resulted in a preliminary prioritised list after exploring the need for simulation based training. Round 3 had an 85% response rate; 17 procedures were eliminated, resulting in a final prioritised list of 19 technical procedures. A national needs assessment using a standardised Delphi method identified a list of procedures that are highly suitable and may provide the basis for future simulation based training programs for vascular surgeons in training. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  8. 75 FR 54063 - Demand Response Compensation in Organized Wholesale Energy Markets; Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ... FURTHER INFORMATION CONTACT: David Hunger (Technical Information), Office of Energy Policy and Innovation....hunger@ferc.gov . Caroline Daly (Technical Information), Office of Energy Policy and [[Page 54064... information about the technical conference or comment procedures, please contact: David Hunger (Technical...

  9. Identifying content for simulation-based curricula in urology: a national needs assessment.

    PubMed

    Nayahangan, Leizl Joy; Bølling Hansen, Rikke; Gilboe Lindorff-Larsen, Karen; Paltved, Charlotte; Nielsen, Bjørn Ulrik; Konge, Lars

    2017-12-01

    Simulation-based training is well recognized in the transforming field of urological surgery; however, integration into the curriculum is often unstructured. Development of simulation-based curricula should follow a stepwise approach starting with a needs assessment. This study aimed to identify technical procedures in urology that should be included in a simulation-based curriculum for residency training. A national needs assessment was performed using the Delphi method involving 56 experts with significant roles in the education of urologists. Round 1 identified technical procedures that newly qualified urologists should perform. Round 2 included a survey using an established needs assessment formula to explore: the frequency of procedures; the number of physicians who should be able to perform the procedure; the risk and/or discomfort to patients when a procedure is performed by an inexperienced physician; and the feasibility of simulation training. Round 3 involved elimination and reranking of procedures according to priority. The response rates for the three Delphi rounds were 70%, 55% and 67%, respectively. The 34 procedures identified in Round 1 were reduced to a final prioritized list of 18 technical procedures for simulation-based training. The five procedures that reached the highest prioritization were cystoscopy, transrectal ultrasound-guided biopsy of the prostate, placement of ureteral stent, insertion of urethral and suprapubic catheter, and transurethral resection of the bladder. The prioritized list of technical procedures in urology that were identified as highly suitable for simulation can be used as an aid in the planning and development of simulation-based training programs.

  10. Teaching and assessing procedural skills using simulation: metrics and methodology.

    PubMed

    Lammers, Richard L; Davenport, Moira; Korley, Frederick; Griswold-Theodorson, Sharon; Fitch, Michael T; Narang, Aneesh T; Evans, Leigh V; Gross, Amy; Rodriguez, Elliot; Dodge, Kelly L; Hamann, Cara J; Robey, Walter C

    2008-11-01

    Simulation allows educators to develop learner-focused training and outcomes-based assessments. However, the effectiveness and validity of simulation-based training in emergency medicine (EM) requires further investigation. Teaching and testing technical skills require methods and assessment instruments that are somewhat different than those used for cognitive or team skills. Drawing from work published by other medical disciplines as well as educational, behavioral, and human factors research, the authors developed six research themes: measurement of procedural skills; development of performance standards; assessment and validation of training methods, simulator models, and assessment tools; optimization of training methods; transfer of skills learned on simulator models to patients; and prevention of skill decay over time. The article reviews relevant and established educational research methodologies and identifies gaps in our knowledge of how physicians learn procedures. The authors present questions requiring further research that, once answered, will advance understanding of simulation-based procedural training and assessment in EM.

  11. The Vocational-Technical Resource Consortia Serving Business and Industry in Ohio. Digest of Study: Operational Procedures for Successful Vocational-Technical Resource Consortia in Serving Business and Industry in Ohio.

    ERIC Educational Resources Information Center

    Frasier, James E.; Stanton, William

    This publication reports the development of the vocational-technical resource consortia in Ohio and identifies the operational procedures associated with successful programs. Five exemplary consortia were studied in some depth; however, data were obtained from all of the 23 consortia in the state. The research indicates that the consortium is an…

  12. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    PubMed

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  13. How family carers engage with technical health procedures in the home: a grounded theory study.

    PubMed

    McDonald, Janet; McKinlay, Eileen; Keeling, Sally; Levack, William

    2015-07-06

    To explore the experiences of family carers who manage technical health procedures at home and describe their learning process. A qualitative study using grounded theory. New Zealand family carers (21 women, 5 men) who managed technical health procedures such as enteral feeding, peritoneal dialysis, tracheostomy care, a central venous line or urinary catheter. In addition, 15 health professionals involved in teaching carers were interviewed. Semistructured interviews were coded soon after completion and preliminary analysis influenced subsequent interviews. Additional data were compared with existing material and as analysis proceeded, initial codes were grouped into higher order concepts until a core concept was described. Interviewing continued until no new ideas emerged and concepts were well defined. The response of carers to the role of managing technical health procedures in the home is presented in terms of five dispositions: (1) Embracing care, (2) Resisting, (3) Reluctant acceptance, (4) Relinquishing and (5) Being overwhelmed. These dispositions were not static and carers commonly changed between them. Embracing care included cognitive understanding of the purpose and benefits of a procedure; accepting a 'technical' solution; practical management; and an emotional response. Accepting embrace is primarily motivated by perceived benefits for the recipient. It may also be driven by a lack of alternatives. Resisting or reluctant acceptance results from a lack of understanding about the procedure or willingness to manage it. Carers need adequate support to avoid becoming overwhelmed, and there are times when it is appropriate to encourage them to relinquish care for the sake of their own needs. The concept of embracing care encourages health professionals to extend their attention beyond simply the practical aspects of technical procedures to assessing and addressing carers' emotional and behavioural responses to health technology during the training process. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Insight into the da Vinci® Xi - technical notes for single-docking left-sided colorectal procedures.

    PubMed

    Ngu, James Chi-Yong; Sim, Sarah; Yusof, Sulaiman; Ng, Chee-Yung; Wong, Andrew Siang-Yih

    2017-12-01

    The adoption of robot-assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi-quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left-sided colorectal procedures. Our initial series of left-sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Between March 2015 and April 2016, 54 cases of robot-assisted laparoscopic left-sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi-quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. The da Vinci® Xi simplifies the docking procedure and makes single-docking feasible for multi-quadrant left-sided colorectal procedures. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Developing a tool to preserve eye contact with patients undergoing colonoscopy for pain monitoring

    PubMed Central

    Niv, Yaron; Tal, Yossi

    2012-01-01

    Colonoscopy has become the leading procedure for early detection and prevention of colorectal cancer. Patients’ experience of colonic endoscopic procedures is scarcely reported, even though it is considered a major factor in colorectal cancer screening participation. Pain due to air inflation or stretching the colon with an endoscope is not rare during examination and may be the main obstacle to cooperation and participation in a screening program. We propose a four-stage study for developing a tool dedicated to pain monitoring during colonoscopy, as follows: (1) comparison of patient, nurse, and endoscopist questionnaire responses about patient pain and technical details of the procedure using the PAINAD tool during colonoscopy; (2) observation of the correlation between patients’ facial expressions and other parameters (using the short PAINAD); (3) development of a device for continuous monitoring of the patient’s facial expression during the procedure; (4) assessment of the usability of such a tool and its contribution to the outcomes of colonoscopy procedures. Early intervention by the staff performing the procedure, in reaction to alerts encoded by this tool, may prevent adverse events during the procedure. PMID:22977314

  16. Enhanced waterflooding design with dilute surfactant concentrations for North Sea conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michels, A.M.; Djojosoeparto, R.S.; Haas, H.

    1996-08-01

    Efficient selection procedures for surfactants have been applied to design a low-concentration surfactant-flooding process for North Sea oilfield application. Anionic surfactants of the propoxy ethoxy glyceryl sulfonate type can be used at 0.1 wt% concentrations together with sacrificial agents and without a polymer drive. Currently estimated unit technical costs (UTC`s)--at 8%--for application in the North Sea oil fields range frommore » $81 to $$94/incremental m{sup 3}, without taking uncertainty factors into account. Including such factors would likely add another $$31/m{sup 3} to the costs.« less

  17. Hysteroscopic simulator for training and educational purposes.

    PubMed

    Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer

    2006-01-01

    Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilizes an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organized curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynecological endoscopic training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopic factors as well as current training and accreditation norms, and proposes a hysteroscopic simulator design that is suitable for educating and training.

  18. Progress report on CCIR studies for guaranteeing access to the geostationary satellite orbit

    NASA Astrophysics Data System (ADS)

    Reinhart, E. E.

    Overall responsibility for preparing a report on the technical information necessary for the World Administrative Radio Conference to be held in the spring of 1984 is vested in the Interim Working Party (IWP) 4/1. The various approaches being considered by the IWP 4/1 to guarantee orbital access are described, along with the criteria that the party has proposed for evaluating and comparing the approaches. These approaches include the following: a regional detailed long-term (10-20 years) a priori allotment plan, a periodically revised (3-5 years) regional detailed allotment plan, a regional or subregional allotment plan with guaranteed access, guaranteed access by means of multilateral coordination, and coordination procedures and technical factors that are revised periodically.

  19. 48 CFR 242.7400 - General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Contractor Facilities 242.7400 General. (a) Program managers may conclude that they need technical... manager may assign technical representatives under the procedures in 242.7401. (b) A technical representative is a representative of a DoD program, project, or system office performing non-CAS technical...

  20. 48 CFR 242.7400 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Contractor Facilities 242.7400 General. (a) Program managers may conclude that they need technical... manager may assign technical representatives under the procedures in 242.7401. (b) A technical representative is a representative of a DoD program, project, or system office performing non-CAS technical...

  1. Patterns of technical error among surgical malpractice claims: an analysis of strategies to prevent injury to surgical patients.

    PubMed

    Regenbogen, Scott E; Greenberg, Caprice C; Studdert, David M; Lipsitz, Stuart R; Zinner, Michael J; Gawande, Atul A

    2007-11-01

    To identify the most prevalent patterns of technical errors in surgery, and evaluate commonly recommended interventions in light of these patterns. The majority of surgical adverse events involve technical errors, but little is known about the nature and causes of these events. We examined characteristics of technical errors and common contributing factors among closed surgical malpractice claims. Surgeon reviewers analyzed 444 randomly sampled surgical malpractice claims from four liability insurers. Among 258 claims in which injuries due to error were detected, 52% (n = 133) involved technical errors. These technical errors were further analyzed with a structured review instrument designed by qualitative content analysis. Forty-nine percent of the technical errors caused permanent disability; an additional 16% resulted in death. Two-thirds (65%) of the technical errors were linked to manual error, 9% to errors in judgment, and 26% to both manual and judgment error. A minority of technical errors involved advanced procedures requiring special training ("index operations"; 16%), surgeons inexperienced with the task (14%), or poorly supervised residents (9%). The majority involved experienced surgeons (73%), and occurred in routine, rather than index, operations (84%). Patient-related complexities-including emergencies, difficult or unexpected anatomy, and previous surgery-contributed to 61% of technical errors, and technology or systems failures contributed to 21%. Most technical errors occur in routine operations with experienced surgeons, under conditions of increased patient complexity or systems failure. Commonly recommended interventions, including restricting high-complexity operations to experienced surgeons, additional training for inexperienced surgeons, and stricter supervision of trainees, are likely to address only a minority of technical errors. Surgical safety research should instead focus on improving decision-making and performance in routine operations for complex patients and circumstances.

  2. [Interpersonal competence in orthopedics and traumatology : Why technical and procedural skills alone are not sufficient].

    PubMed

    Seemann, R; Münzberg, M; Stange, R; Rüsseler, M; Egerth, M; Bouillon, B; Hoffmann, R; Mutschler, M

    2016-10-01

    Patient safety has increasingly gained significance as criterion which clinics and doctors will be measured against in terms of ethics and finances. The "human factor" moved into focus regarding the question of how to reduce treatment errors in clinical daily routine. Nevertheless, systematic mediation of interpersonal competences only plays a minor role in the catalogue of requirements for medical specialization and professional training. This is the case not only in orthopedics and traumatology, but in other medical fields as well. At the insistence of DGOU and in cooperation with Lufthansa Flight Training, a training model was initiated, comparable to training models used in aviation. In aviation, apart from the training of procedural and technical abilities, regular soft skills training has become standard in the training of all Lufthansa staff. Several studies confirm that by improving communication, interaction, and teamwork skills not only a reduction of intolerable incidents is observed, but also a positive economic effect. Interpersonal competences should be firmly anchored in orthopedics and traumatology and thus be implemented as third post in specialist training.

  3. 48 CFR 2052.216-72 - Task order procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...; (5) Technical skills required; and (6) Estimated level of effort. (b) Task order technical proposal. By the date specified in the TORFP, the contractor shall deliver to the contracting officer a written or verbal (as specified in the TORFP technical proposal submittal instructions) technical proposal...

  4. 15 CFR 911.8 - Technical requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... PROCEDURES CONCERNING USE OF THE NOAA SPACE-BASED DATA COLLECTION SYSTEMS § 911.8 Technical requirements. (a) All platform operators of the NOAA DCS must use a data collection platform radio set whose technical...

  5. 15 CFR 911.8 - Technical requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... PROCEDURES CONCERNING USE OF THE NOAA SPACE-BASED DATA COLLECTION SYSTEMS § 911.8 Technical requirements. (a) All platform operators of the NOAA DCS must use a data collection platform radio set whose technical...

  6. 15 CFR 911.8 - Technical requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... PROCEDURES CONCERNING USE OF THE NOAA SPACE-BASED DATA COLLECTION SYSTEMS § 911.8 Technical requirements. (a) All platform operators of the NOAA DCS must use a data collection platform radio set whose technical...

  7. 15 CFR 911.8 - Technical requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... PROCEDURES CONCERNING USE OF THE NOAA SPACE-BASED DATA COLLECTION SYSTEMS § 911.8 Technical requirements. (a) All platform operators of the NOAA DCS must use a data collection platform radio set whose technical...

  8. 15 CFR 911.8 - Technical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PROCEDURES CONCERNING USE OF THE NOAA SPACE-BASED DATA COLLECTION SYSTEMS § 911.8 Technical requirements. (a) All platform operators of the NOAA DCS must use a data collection platform radio set whose technical...

  9. Assisted Reproduction: What factors interfere in the professional's decisions? Are single women an issue?

    PubMed Central

    2011-01-01

    Background With the development of medical technology, many countries around the world have been implementing ethical guidelines and laws regarding Medically Assisted Reproduction (MAR). A physician's reproductive decisions are not solely based on technical criteria but are also influenced by society values. Therefore, the aim of this study was to analyze the factors prioritized by MAR professionals when deciding on whether to accept to perform assisted reproduction and to show any existing cultural differences. Methods Cross-sectional study involving 224 healthcare professionals working with assisted reproduction in Brazil, Italy, Germany and Greece. Instrument used for data collection: a questionnaire, followed by the description of four special MAR cases (a single woman, a lesbian couple, an HIV discordant couple and gender selection) which included case-specific questions regarding the professionals' decision on whether to perform the requested procedure as well as the following factors: socio-demographic variables, moral and legal values as well as the technical aspects which influence decision-making. Results Only the case involving a single woman who wishes to have a child (without the intention of having a partner in the future) demonstrated significant differences. Therefore, the study was driven towards the results of this case specifically. The analyses we performed demonstrated that professionals holding a Master's Degree, those younger in age, female professionals, those having worked for less time in reproduction, those in private clinics and Brazilian health professionals all had a greater tendency to perform the procedure in that case. A multivariate analysis demonstrated that the reasons for the professional's decision to perform the procedure were the woman's right to gestate and the duty of MAR professionals to help her. The professionals who decided not to perform the procedure identified the woman's marital status and the child's right to a father as the reason to withhold treatment. Conclusion The study indicates differences among countries in the evaluation of the single woman case. It also discloses the undervaluation of bioethics committees and the need for a greater participation of healthcare professionals in debates on assisted reproduction laws. PMID:21627812

  10. Assisted reproduction: what factors interfere in the professional's decisions? Are single women an issue?

    PubMed

    Záchia, Suzana; Knauth, Daniela; Goldim, José R; Chachamovich, Juliana R; Chachamovich, Eduardo; Paz, Ana H; Felberbaum, Ricardo; Crosignani, PierGiorgio; Tarlatzis, Basil C; Passos, Eduardo P

    2011-05-31

    With the development of medical technology, many countries around the world have been implementing ethical guidelines and laws regarding Medically Assisted Reproduction (MAR). A physician's reproductive decisions are not solely based on technical criteria but are also influenced by society values. Therefore, the aim of this study was to analyze the factors prioritized by MAR professionals when deciding on whether to accept to perform assisted reproduction and to show any existing cultural differences. Cross-sectional study involving 224 healthcare professionals working with assisted reproduction in Brazil, Italy, Germany and Greece. Instrument used for data collection: a questionnaire, followed by the description of four special MAR cases (a single woman, a lesbian couple, an HIV discordant couple and gender selection) which included case-specific questions regarding the professionals' decision on whether to perform the requested procedure as well as the following factors: socio-demographic variables, moral and legal values as well as the technical aspects which influence decision-making. Only the case involving a single woman who wishes to have a child (without the intention of having a partner in the future) demonstrated significant differences. Therefore, the study was driven towards the results of this case specifically. The analyses we performed demonstrated that professionals holding a Master's Degree, those younger in age, female professionals, those having worked for less time in reproduction, those in private clinics and Brazilian health professionals all had a greater tendency to perform the procedure in that case. A multivariate analysis demonstrated that the reasons for the professional's decision to perform the procedure were the woman's right to gestate and the duty of MAR professionals to help her. The professionals who decided not to perform the procedure identified the woman's marital status and the child's right to a father as the reason to withhold treatment. The study indicates differences among countries in the evaluation of the single woman case. It also discloses the undervaluation of bioethics committees and the need for a greater participation of healthcare professionals in debates on assisted reproduction laws.

  11. CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma: specific technical aspects and clinical results.

    PubMed

    Sommer, C M; Lemm, G; Hohenstein, E; Bellemann, N; Stampfl, U; Goezen, A S; Rassweiler, J; Kauczor, H U; Radeleff, B A; Pereira, P L

    2013-06-01

    This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  12. Cost Finding Principles and Procedures. Preliminary Field Review Edition. Technical Report 26.

    ERIC Educational Resources Information Center

    Ziemer, Gordon; And Others

    This report is part of the Larger Cost Finding Principles Project designed to develop a uniform set of standards, definitions, and alternative procedures that will use accounting and statistical data to find the full cost of resources utilized in the process of producing institutional outputs. This technical report describes preliminary procedures…

  13. Technical Operating Procedures for Providing Funding to Natural Resource Trustees to Conduct an Initiation of Assessment of Natural Resource Damages Under the Oil Pollution Act of 1990

    DOT National Transportation Integrated Search

    1996-06-01

    Technical Operating Procedures (TOPS) for Providing Funding to Natural Resources : Trustees To Conduct An Initiation of Assessment of Natural Resource Damages : under the Oil Pollution Act of 1990 have been developed to provide guidance on : funding ...

  14. Policies and Procedures Governing the Operation of Vocational-Technical Education in Nevada.

    ERIC Educational Resources Information Center

    Nevada State Dept. of Education, Carson City. Div. of Vocational-Technical and Adult Education.

    This manual was prepared to assist local public schools in organizing and conducting a broadened program of vocational education of significant scope. Operating policies and procedures are provided in areas of: (1) Administration of Vocational-Technical Education, (2) Agricultural Education, (3) Vocational Business and Office Occupations, (4)…

  15. Value Engineering. Technical Manual. School Facilities Development Procedures Manual.

    ERIC Educational Resources Information Center

    Washington Office of the State Superintendent of Public Instruction, Olympia.

    Value Engineering (VE) is a cost-optimizing technique used to analyze design quality and cost-effectiveness. The application of VE procedures to the design and construction of school facilities has been adopted by the state of Washington. This technical manual provides guidance in developing the scope and applicability of VE to school projects; in…

  16. 75 FR 34734 - Improving Market and Planning Efficiency Through Improved Software; Notice of Agenda and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... Market and Planning Efficiency Through Improved Software; Notice of Agenda and Procedures for Staff Technical Conference June 10, 2010. This notice establishes the agenda and procedures for the staff[email protected] . Kimberly D. Bose, Secretary. Agenda for AD10-12 Staff Technical Conference on Enhanced Power...

  17. US-Guided, Direct Puncture Retrograde Thoracic Duct Access, Lymphangiography, and Embolization: Feasibility and Efficacy.

    PubMed

    Guevara, Carlos J; Rialon, Kristy L; Ramaswamy, Raja S; Kim, Seung K; Darcy, Michael D

    2016-12-01

    To describe technical details, success rate, and advantages of direct puncture of the thoracic duct (TD) under direct ultrasound (US) guidance at venous insertion in the left neck. All patients who underwent attempted thoracic duct embolization (TDE) via US-guided retrograde TD access in the left neck were retrospectively reviewed. Indications for lymphangiography were iatrogenic chyle leak, pulmonary lymphangiectasia, and plastic bronchitis. Ten patients with mean age 41.4 years (range, 21 d to 72 y) underwent US-guided TD access via the left neck. Technical details, procedural times, and clinical outcomes were evaluated. TD access time was defined as time from start of procedure to successful access of TD, and total procedural time was defined from start of procedure until TDE. All attempts at TD access via the neck were successful. Technical and clinical success of TDE was 60%. There were no complications. Mean TD access time was 17 minutes (range, 2-47 min), and mean total procedure time was 49 minutes (range, 25-69 min). Mean follow-up time was 5.4 months (range, 3-10 months). TDE via US-guided access in the left neck is technically feasible and safe with a potential decrease in procedure time and elimination of oil-based contrast material. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  18. 48 CFR 252.246-7001 - Warranty of data.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...

  19. 48 CFR 252.246-7001 - Warranty of data.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...

  20. 48 CFR 252.246-7001 - Warranty of data.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...

  1. 48 CFR 252.246-7001 - Warranty of data.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...

  2. 48 CFR 252.246-7001 - Warranty of data.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...

  3. Simulation fails to replicate stress in trainees performing a technical procedure in the clinical environment.

    PubMed

    Baker, B G; Bhalla, A; Doleman, B; Yarnold, E; Simons, S; Lund, J N; Williams, J P

    2017-01-01

    Simulation-based training (SBT) has become an increasingly important method by which doctors learn. Stress has an impact upon learning, performance, technical, and non-technical skills. However, there are currently no studies that compare stress in the clinical and simulated environment. We aimed to compare objective (heart rate variability, HRV) and subjective (state trait anxiety inventory, STAI) measures of stress theatre with a simulated environment. HRV recordings were obtained from eight anesthetic trainees performing an uncomplicated rapid sequence induction at pre-determined procedural steps using a wireless Polar RS800CX monitor © in an emergency theatre setting. This was repeated in the simulated environment. Participants completed an STAI before and after the procedure. Eight trainees completed the study. The theatre environment caused an increase in objective stress vs baseline (p = .004). There was no significant difference between average objective stress levels across all time points (p = .20) between environments. However, there was a significant interaction between the variables of objective stress and environment (p = .045). There was no significant difference in subjective stress (p = .27) between environments. Simulation was unable to accurately replicate the stress of the technical procedure. This is the first study that compares the stress during SBT with the theatre environment and has implications for the assessment of simulated environments for use in examinations, rating of technical and non-technical skills, and stress management training.

  4. 42 CFR 493.1838 - Training and technical assistance for unsuccessful participation in proficiency testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Training and technical assistance for unsuccessful... REQUIREMENTS Enforcement Procedures § 493.1838 Training and technical assistance for unsuccessful participation... may require the laboratory to undertake training of its personnel, or to obtain necessary technical...

  5. Unresolved Technical Issues in Fair Interest Measurement.

    ERIC Educational Resources Information Center

    Cole, Nancy S.

    The problem of sex differences in interest measurement involves many technical issues and procedures. The purpose of this paper is to provide a description of the technical problems involved in construction, scoring, and interpretation of interest measures as related to sex differences and to suggest guidelines within these technical issues which…

  6. Fluoroscopy-assisted vs fluoroless endoscopic ultrasound-guided transmural drainage of pancreatic fluid collections: A comparative study.

    PubMed

    Consiglieri, Claudia F; Gornals, Joan B; Busquets, Juli; Peláez, Nuria; Secanella, Lluis; De-La-Hera, Meritxell; Sanzol, Resurrección; Fabregat, Joan; Castellote, José

    2018-01-01

    The need for fluoroscopy guidance in patients undergoing endoscopic ultrasound-guided transmural drainage (EUS-TMD) of peripancreatic fluid collections (PFCs) remains unclear. The aim of this study was to compare general outcomes of EUS-TMD of PFCs under fluoroscopy (F) vs fluoroless (FL). This is a comparative study with a retrospective analysis of a prospective and consecutive inclusion database at a tertiary centre, from 2009 to 2015. All patients were symptomatic pseudocyst (PSC) and walled-off pancreatic necrosis (WON). Two groups were assigned depending on availability of fluoroscopy. The groups were heterogeneous in terms of their demographic characteristics, PFCs and procedure. The main outcome measures included technical and clinical success, incidences, adverse events (AEs), and follow-up. Fifty EUS-TMD of PFCs from 86 EUS-guided drainages were included during the study period. Group F included 26 procedures, PSC 69.2%, WON 30.8%, metal stents 61.5% (46.1% lumen-apposing stent) and plastic stents 38.5%. Group FL included 24 procedures, PSC 37.5%, WON 62.5%, and metal stents 95.8% (lumen-apposing stents). Technical success was 100% in both groups, and clinical success was similar (F 88.5%, FL 87.5%). Technical incidences and intra-procedure AEs were only described in group F (7.6% and 11.5%, respectively) and none in group FL. Procedure time was less in group FL (8min, p=0.0341). Fluoroless in the EUS-TMD of PFCs does not involve more technical incidences or intra-procedure AEs. Technical and clinical success was similar in the two groups. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  7. Guidelines for producing training films and videos.

    PubMed

    Harper, P B

    1991-01-01

    Drawing from experience in producing a film on the surgical procedure of female sterilization, 4 guidelines to technical film production for training purposes are presented and discussed in this paper. In order of presentation in the text, the paper 1st encourages identifying and securing a technical expert, then clearly identifying steps of the technical procedure, involving trainees and trainers in the production process, and working with experienced producers, scriptwriters, and crew members. Returning to the 1st guideline, the technical advisor will have a central presence during all photography and editing, and ideally should not have any personal investment in the procedure being shown. Prior to script finalization and sorting, research is urged to ensure concrete procedural steps. Printed materials, slides, interviews of experienced clinicians, procedure observation, and test videotape shooting may be called upon and employed as parts of the research phase. Trainees should participate during preliminary research, script development, and pretesting of early film versions, their suggestions for change incorporated where appropriate in the final version. On the final point of securing experienced workers, country nationals sensitive to relevant cultural and background dynamics should be included in the team. The special concerns of airport security regulation and customs requirements knowledge are essential, as well as their attention to assuring adequate on-site electricity for camera equipment.

  8. Treatment of benign biliary leaks with transhepatic placement of coated self-expanding metallic stents.

    PubMed

    Páramo, M; García-Barquín, P; Carrillo, M; Millor Muruzábal, M; Vivas, I; Bilbao, J I

    To analyze the safety and efficacy of percutaneous placement of coated self-expanding metallic stents (SEMS) in patients with biliary leaks. This ethics committee at our center approved this study. We retrospectively reviewed all coated SEMS placed between October 2008 and September 2015. We analyzed patient-related factors such as the primary underlying disease, prior hepatic procedures, and clinical outcome. We evaluated the location, the number and type of leak (anastomotic or non-anastomotic), and the characteristics of the interventional procedure (number of stents deployed, location of the stents, technical success, and primary functionality). We recorded the complications registered. We studied 14 patients (11 men and 3 women). The mean follow-up period was 375.5 days (range 15-1920 days). Leaks were postsurgical in 12 patients. One patient developed an arteriobilioportal fistula. In another, the biliary leak occurred secondary to the rupture of the common bile duct after ERCP. A total of 23 coated SEMS were placed, including 21 Fluency ® stents (Bard, Tempe, AZ, USA) and 2 Wallflex ® stents (Boston Scientific, Galway, Republic of Ireland). The technical success of the procedure was considered total in 11 (78.6%) patients, partial in 2 (14.3%) patients, and null in 1 (7.2%) patient. The clinical outcome was good in 13 of the 14 patients. The mean period of primary functionality of the coated SEMS was 331 days (range 15-1920 days). No major complications were observed in 11 (78.6%) patients. Percutaneous placement of coated SEMS for the treatment of benign biliary leaks is safe and efficacious, with a high rate of technical and clinical success and a moderate rate of complications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Submucosal Tunneling Endoscopic Resection vs Thoracoscopic Enucleation for Large Submucosal Tumors in the Esophagus and the Esophagogastric Junction.

    PubMed

    Chen, Tao; Lin, Zong-Wu; Zhang, Yi-Qun; Chen, Wei-Feng; Zhong, Yun-Shi; Wang, Qun; Yao, Li-Qing; Zhou, Ping-Hong; Xu, Mei-Dong

    2017-12-01

    Submucosal tunneling endoscopic resection (STER) is regarded as a promising method for resection of submucosal tumors (SMTs); however, little is known about a comprehensive comparison of STER and thoracoscopic enucleation (TE). The aim of this study was to compare the clinical outcomes of STER and TE for large symptomatic SMTs in the esophagus and esophagogastric junction, as well as to analyze the factors that affect the feasibility and safety of STER. We enrolled 166 patients with large symptomatic SMTs in the esophagus and esophagogastric junction from September 2011 to March 2016 in this retrospective study. The clinicopathologic features and treatment results were collected and analyzed. En bloc resection was achieved in 84.6% of the patients in the STER group and 86.7% of the patients in the TE group (p = 0.708). Notably, the procedure time and hospital stay in the STER group were considerably shorter than those in the TE group. Tumor transverse diameter is a significant risk factor for piecemeal resection, adverse events, and technical difficulties. No recurrence or metastasis was found during a mean follow-up period of more than 2 years. Submucosal tunneling endoscopic resection is effective and safe for large SMTs in the esophagus and esophagogastric junction. This procedure has the advantage of being more minimally invasive with a shorter procedure time and hospital stay compared with TE. Submucosal tunneling endoscopic resection for tumors with a transverse diameter ≥3.5 cm and an irregular shape is associated with relatively high risk for piecemeal resection, adverse events, and technical difficulties. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Energy recovery from solid waste. Volume 2: Technical report. [pyrolysis and biodegradation

    NASA Technical Reports Server (NTRS)

    Huang, C. J.; Dalton, C.

    1975-01-01

    A systems analysis of energy recovery from solid waste demonstrates the feasibility of several current processes for converting solid waste to an energy form. The social, legal, environmental, and political factors are considered in depth with recommendations made in regard to new legislation and policy. Biodegradation and thermal decomposition are the two areas of disposal that are considered with emphasis on thermal decomposition. A technical and economic evaluation of a number of available and developing energy-recovery processes is given. Based on present technical capabilities, use of prepared solid waste as a fuel supplemental to coal seems to be the most economic process by which to recover energy from solid waste. Markets are considered in detail with suggestions given for improving market conditions and for developing market stability. A decision procedure is given to aid a community in deciding on its options in dealing with solid waste, and a new pyrolysis process is suggested. An application of the methods of this study are applied to Houston, Texas.

  11. 77 FR 48112 - Pipeline Safety: Administrative Procedures; Updates and Technical Corrections

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ...This Notice of Proposed Rulemaking updates the administrative civil penalty maximums for violation of the pipeline safety regulations to conform to current law, updates the informal hearing and adjudication process for pipeline enforcement matters to conform to current law, amends other administrative procedures used by PHMSA personnel, and makes other technical corrections and updates to certain administrative procedures. The proposed amendments do not impose any new operating, maintenance, or other substantive requirements on pipeline owners or operators.

  12. A Review of Legal Decisions Relevant to Technical Standards Used in Pharmacy School Admissions

    PubMed Central

    2017-01-01

    The implementation of an effective and legally sound technical standards procedure for pharmacy schools requires a proactive approach by admissions officers. Applicants with disabilities are accorded significant rights that must not be infringed during the admissions process in order to ensure compliance with applicable law. This article provides a review of applicable state cases, federal cases, and OCR decisions and guidance to help pharmacy schools identify procedures and implement technical standards into their admissions processes as required by ACPE Standards 2016. PMID:28381897

  13. Principles and Procedures in Technical Assistance: An Approach to Educational Change

    ERIC Educational Resources Information Center

    Lillie, David L.; Black, Talbot

    1976-01-01

    The Technical Assistance Development System (TADS) has developed through the years a system for technical assistance and has identified some important principles that should be followed in the operation of organizational support systems. (Author/ER)

  14. Long-term outcomes and risk factors of biliary stent dysfunction after endoscopic double stenting for malignant biliary and duodenal obstructions.

    PubMed

    Matsumoto, Kazuyuki; Kato, Hironari; Tsutsumi, Koichiro; Mizukawa, Sho; Yabe, Syuntaro; Seki, Hiroyuki; Akimoto, Yutaka; Uchida, Daisuke; Tomoda, Takeshi; Yamamoto, Naoki; Horiguchi, Shigeru; Kuwaki, Kenji; Okada, Hiroyuki

    2017-07-01

    Few reports describe the endoscopic double-stenting procedure for malignant biliary and duodenal obstructions. We evaluated the clinical outcomes from double stenting, and analyzed the risk factors for biliary stent dysfunction following double stenting. Eighty-one patients who underwent endoscopic double stenting for malignant biliary and duodenal obstructions were retrospectively analyzed. We determined the stent dysfunction rate and the biliary stent dysfunction risk factors, and analyzed the endoscopic reintervention results. Overall survival time and survival time following double stenting were 365 (38-1673) days and 73 (20-954) days, respectively. After double stenting, the 3-month and 6-month duodenal stent dysfunction rates were 14% and 41%, respectively. Reintervention technical success rate was 100% (10/10), and mean gastric outlet obstruction scoring system scores improved from 0.7 to 2.4 points (P < 0.001). The 3-month and 6-month biliary stent dysfunction rates were 26% and 41%, respectively. The reintervention technical and clinical success rates were 95% (20/21) and 81% (17/21), respectively. Risk factors for biliary stent dysfunction following double stenting were events associated with duodenal stent dysfunction (odds ratio [OR], 11.1; 95% confidence interval [CI], 2.09-87.4; P = 0.0044) and the biliary stent end's location (OR, 6.93; 95% CI, 1.37-40.2; P = 0.0019). Some patients had stent dysfunction irrespective of the survival period after double stenting. Endoscopic reintervention was technically feasible and clinically effective even after double stenting. Duodenal stent dysfunction and biliary stent end's location were risk factors for biliary stent dysfunction. © 2017 Japan Gastroenterological Endoscopy Society.

  15. Technical note: Design flood under hydrological uncertainty

    NASA Astrophysics Data System (ADS)

    Botto, Anna; Ganora, Daniele; Claps, Pierluigi; Laio, Francesco

    2017-07-01

    Planning and verification of hydraulic infrastructures require a design estimate of hydrologic variables, usually provided by frequency analysis, and neglecting hydrologic uncertainty. However, when hydrologic uncertainty is accounted for, the design flood value for a specific return period is no longer a unique value, but is represented by a distribution of values. As a consequence, the design flood is no longer univocally defined, making the design process undetermined. The Uncertainty Compliant Design Flood Estimation (UNCODE) procedure is a novel approach that, starting from a range of possible design flood estimates obtained in uncertain conditions, converges to a single design value. This is obtained through a cost-benefit criterion with additional constraints that is numerically solved in a simulation framework. This paper contributes to promoting a practical use of the UNCODE procedure without resorting to numerical computation. A modified procedure is proposed by using a correction coefficient that modifies the standard (i.e., uncertainty-free) design value on the basis of sample length and return period only. The procedure is robust and parsimonious, as it does not require additional parameters with respect to the traditional uncertainty-free analysis. Simple equations to compute the correction term are provided for a number of probability distributions commonly used to represent the flood frequency curve. The UNCODE procedure, when coupled with this simple correction factor, provides a robust way to manage the hydrologic uncertainty and to go beyond the use of traditional safety factors. With all the other parameters being equal, an increase in the sample length reduces the correction factor, and thus the construction costs, while still keeping the same safety level.

  16. NECAP 4.1: NASA's energy-cost analysis program user's manual

    NASA Technical Reports Server (NTRS)

    Jensen, R. N.; Henninger, R. H.; Miner, D. L.

    1983-01-01

    The Enery Cost Analysis Program (NECAP) is a powerful computerized method to determine and to minimize building energy consumption. The program calculates hourly heat gain or losses taking into account the building thermal resistance and mass, using hourly weather and a "response factor' method. Internal temperatures are allowed to vary in accordance with thermostat settings and equipment capacity. A simplified input procedure and numerous other technical improvements are presented. This Users Manual describes the program and provides examples.

  17. Why does Acute Postwhiplash Injury Pain Transform into Chronic Pain Multimodal Assessment of Risk Factors and Predictors of Pain Chronification

    DTIC Science & Technology

    2016-10-19

    data acquisition. iii. We determined working procedures with the Technion genetic lab. iv. We exercised data transfer between our site and the MRI ... MRI protocols and training of the technical staff. viii. A meeting of the study investigators was held during the world pain conference in Japan in...participated in the study. 20 subjects had withdrawn their consent mainly due to MRI scanner availability and scheduling issues, or excluded from the

  18. SADI-S WITH RIGHT GASTRIC ARTERY LIGATION: TECHNICAL SYSTEMATIZATION AND EARLY RESULTS

    PubMed Central

    GEBELLI, Jordi Pujol; de GORDEJUELA, Amador Garcia Ruiz; RAMOS, Almino Cardoso; NORA, Mario; PEREIRA, Ana Marta; CAMPOS, Josemberg Marins; RAMOS, Manoela Galvão; BASTOS, Eduardo Lemos de Souza; MARCHESINI, João Batista

    2016-01-01

    ABSTRACT Background: Bariatric surgery is performed all over the world with close to 500.000 procedures per year. The most performed techniques are Roux-en-Y gastric bypass and sleeve gastrectomy. Despite this data, the most effective procedure, biliopancreatic diversion with or without duodenal switch, represents only no more than 1.5% of the procedures. Technical complexity, morbidity, mortality, and severe nutritional adverse effects related to the procedure are the main fears that prevent most universal acceptance. Aim: To explain the technical aspects and the benefits of the SADI-S with right gastric artery ligation as an effective simplification from the original duodenal switch. Methods: Were included all patients undergoing this procedure from the November 2014 to May 2016, describing and analysing aspects of this technique, the systematization and early complications associated with the procedure. Results: A series of 67 patients were operated; 46 were women (68.7%); mean age of the group was 44 years old (33-56); and an average BMI of 53.5 kg/m2 (50-63.5). Surgical time was 115 min (80-180). A total of five patients (7.5%) had any complication and two (2.9%) had to be reoperated. There were two patients with leak, one at the duodenal stump and other at the esophagogastric angle. There was no mortality. Patients stayed at the hospital a median of 2.5 days (1-25). Conclusions: SADI-S with right gastric artery ligation is a safe procedure with few preliminary complications. The technical variations introduced to the classical duodenal switch are reproducible and may allow this procedure to be more popular. All the complications in this series were not related to the ligation of the right gastric artery. PMID:27683784

  19. Radiation exposure from fluoroscopy during orthopedic surgical procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, S.A.

    1989-11-01

    The use of fluoroscopy has enabled orthopedic surgeons to become technically more proficient. In addition, these surgical procedures tend to have less associated patient morbidity by decreasing operative time and minimizing the area of the operative field. The trade-off, however, may be an increased risk of radiation exposure to the surgeon on an annual or lifetime basis. The current study was designed to determine the amount of radiation received by the primary surgeon and the first assistant during selected surgical procedures involving the use of fluoroscopy. Five body sites exposed to radiation were monitored for dosage. The results of thismore » study indicate that with appropriate usage, (1) radiation exposure from fluoroscopy is relatively low; (2) the surgeon's dominant hand receives the most exposure per case; and (3) proper maintenance and calibration of fluoroscopic machines are important factors in reducing exposure risks. Therefore, with proper precautions, the use of fluoroscopy in orthopedic procedures can remain a safe practice.« less

  20. Restoring tactile and erogenous penile sensation in low-spinal-lesion patients: procedural and technical aspects following 43 TOMAX nerve transfer procedures.

    PubMed

    Overgoor, Max L E; de Jong, Tom P V M; Kon, Moshe

    2014-08-01

    The "TOMAX" (TO MAX-imize sensation, sexuality, and quality of life) procedure restores genital sensation in men with low spinal lesions, improving sexual health, as shown previously. It connects the dorsal nerve of the penis to the intact ipsilateral ilioinguinal nerve, unilaterally or bilaterally. This study reports on the technical aspects based on 43 TOMAX nerve transfers. In 40 patients with no penile but intact groin sensation, 43 nerve transfers were performed. Data on patient selection, surgical history, anatomy of the ilioinguinal nerve and dorsal nerve of the penis, unilateral or bilateral surgery, surgical technique, complications, and patient information were collected prospectively. Regardless of origin, all patients with no penile but good groin sensation are eligible for the procedure, provided the ilioinguinal nerve is not damaged because of former inguinal surgery or absent because of anatomical variations. Selection of a unilateral or bilateral procedure depends on the presence or absence of reflex erections and bulbocavernosus reflex. Preliminary experience with the first three bilateral cases shows that it is technically feasible, with encouraging results. The surgical technique has evolved (described in detail, including video) to enhance outcome and reduce complications. Patients are better informed, resulting in realistic expectations. This article synthesizes the procedural and technical experience of 43 TOMAX nerve transfers. Anyone skilled in peripheral nerve surgery and microsurgery can adopt this concept and further develop it. The TOMAX procedure can then be used to restore erogenous penile sensation and improve the quality of sexual health in patients with absent penile but good groin sensation.

  1. How family carers engage with technical health procedures in the home: a grounded theory study

    PubMed Central

    McDonald, Janet; McKinlay, Eileen; Keeling, Sally; Levack, William

    2015-01-01

    Objectives To explore the experiences of family carers who manage technical health procedures at home and describe their learning process. Design A qualitative study using grounded theory. Participants New Zealand family carers (21 women, 5 men) who managed technical health procedures such as enteral feeding, peritoneal dialysis, tracheostomy care, a central venous line or urinary catheter. In addition, 15 health professionals involved in teaching carers were interviewed. Methods Semistructured interviews were coded soon after completion and preliminary analysis influenced subsequent interviews. Additional data were compared with existing material and as analysis proceeded, initial codes were grouped into higher order concepts until a core concept was described. Interviewing continued until no new ideas emerged and concepts were well defined. Results The response of carers to the role of managing technical health procedures in the home is presented in terms of five dispositions: (1) Embracing care, (2) Resisting, (3) Reluctant acceptance, (4) Relinquishing and (5) Being overwhelmed. These dispositions were not static and carers commonly changed between them. Embracing care included cognitive understanding of the purpose and benefits of a procedure; accepting a ‘technical’ solution; practical management; and an emotional response. Accepting embrace is primarily motivated by perceived benefits for the recipient. It may also be driven by a lack of alternatives. Resisting or reluctant acceptance results from a lack of understanding about the procedure or willingness to manage it. Carers need adequate support to avoid becoming overwhelmed, and there are times when it is appropriate to encourage them to relinquish care for the sake of their own needs. Conclusions The concept of embracing care encourages health professionals to extend their attention beyond simply the practical aspects of technical procedures to assessing and addressing carers’ emotional and behavioural responses to health technology during the training process. PMID:26150143

  2. Procedures For Microbial-Ecology Laboratory

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Microbial Ecology Laboratory Procedures Manual provides concise and well-defined instructions on routine technical procedures to be followed in microbiological laboratory to ensure safety, analytical control, and validity of results.

  3. An adequate level of training for technically competent colonoscopic polypectomy.

    PubMed

    Boo, Sun-Jin; Jung, Ji Hoon; Park, Jae Ho; Na, Soo-Young; Kim, Seon Ok; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho; Byeon, Jeong-Sik

    2015-07-01

    The purpose of this study is to investigate the learning curve for colonoscopic polypectomy (CP) by trainee endoscopists. The amount of training required to achieve technical competence for CP is uncertain. The CP times and en bloc resection rates of three experienced colonoscopists were obtained from 240 procedures. These data were compared to those of three gastroenterology trainees who performed 750 CP procedures. A trainee procedure was deemed to be a success if en bloc resection was obtained and the CP time was within twice the median CP time of the experienced colonoscopists. Trainees were deemed to be technically competent when they achieved a CP success rate of greater than or equal to 80%. The median CP times and en bloc resection rates for the experienced colonoscopists and trainees were 79 s (range, 20-301 s) and 99.6% (239/240), and 118 s (range, 36-1051 s) and 95.6% (717/750), respectively. The trainee success rate of CP was 72% (540/750). The success rate of the procedure was associated with increased trainee experience (p = 0.003) and reached 80% after 250 procedures. The CP time significantly decreased (p < 0.001) and en bloc resection rate significantly increased (p = 0.011) as trainee experience accumulated. The level of experience was an independent predictor for successful CP. The achievement of technical competence with CP was associated with an accumulation of approximately 250 procedures. These findings suggest that dedicated education and training programs for CP are warranted.

  4. Trochleoplasty: Indications and Technique.

    PubMed

    Nolan, John E; Schottel, Patrick C; Endres, Nathan K

    2018-05-09

    Trochlear dysplasia is a well-described risk factor for patellar instability. Trochleoplasty has emerged as a procedure within the surgical armamentarium for patellar instability, yet its role is unclear. A variety of trochleoplasty procedures have emerged. The purpose of this review is to clarify indications for trochleoplasty, outline the technical steps involved in performing common trochleoplasties and report the published outcomes and potential complications of these procedures. Patellar instability with severe trochlear dysplasia is the main indication for trochleoplasty. Three types of trochleoplasty have emerged: (1) lateral facet elevation; (2) sulcus deepening; and (3) recession wedge. Deepening and recession wedge trochleoplasties are the most commonly performed. Trochleoplasty is a surgical option for addressing patellar instability in patients with severe trochlear dysplasia. Deepening and recession wedge trochleoplasties that address Dejour B and D dysplastic trochleas are the most studied, with both short- and midterm outcomes reported. Long-term outcomes are lacking and comparative studies are needed.

  5. Efficacy and complications in the use of self-expanding colonic stents: an analysis of 15 years' experience.

    PubMed

    Samper Wamba, J D; Fernández Martínez, A; González Pastrana, L; López González, L; Balboa Arregui, Ó

    2015-01-01

    To analyze the efficacy and safety of the procedure for placing self-expanding stents in the colon. To evaluate the factors associated with complications. To analyze the dose of radiation delivered in the procedure. This was a retrospective descriptive study of 478 procedures done at a single center to place self-expanding metallic stents in the colon. A total of 423 nitinol stents and 79 stainless steel stents were placed. We included all colonic obstructions, of which 446 had malignant causes and 8 had benign causes. We excluded patients with intestinal perforation, severe colonic bleeding, short life expectancy, or lesions located less than 5 cm from the anus. We collected the dosimetric data and analyzed the technical success, clinical success, and complications during follow-up. The procedure was a technical success in 92.26% of cases (n=441) and a clinical success in 78.45% (n=375); complications occurred during follow-up in 18.5% of cases. Complications occurred more frequently with the stainless steel stents than with the nitinol stents (OR: 3.2; 95% CI: 1.8-5.7). The mean value of the dose area product was 35 Gy*cm(2). When instead of being done by the interventional radiologist working together with an endoscopist the procedure was done exclusively by the interventional radiologist, the time under fluoroscopy (p=0.001), dose area product (p=0.029), and kinetic energy released per unit mass (p=0.001) were greater. The procedure for placing self-expanding colonic stents is efficacious and safe with an acceptable rate of complications. The doses of radiation delivered were low, and the radiation doses and time under fluoroscopy were lower when the procedure was done together with an endoscopist. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  6. Feasible and technical aspects of transcatheter arterial chemoembolization for non-resectable hepatocellular carcinoma using a 3.5-French catheter system.

    PubMed

    Yagyu, Yukinobu; Tsurusaki, Masakatsu; Kamiyama, Kazutoshi; Kitagaki, Hajime; Murakami, Takamichi

    2014-12-01

    To evaluate the feasibility and technical aspects of transcatheter arterial chemoembolization (TACE) for non-resectable hepatocellular carcinoma (HCC) using a 3.5-French (Fr) catheter system. This study included 328 consecutive cases of HCC among 232 patients who underwent TACE procedures using both a 3.5-Fr catheter system and a microcatheter fitted to a 3.5-Fr system between April 2009 and November 2011. We assessed the ability to reach the catheter into the proper hepatic artery (PHA), main hepatic branch, segmental artery, and subsegmental or sub-subsegmental artery. The feasibility was rated according to the following factors: (1) the number of arteries that could be used to reach the target artery/total number of procedures using the 3.5-Fr system, (2) the rate of successful completion of the procedures without changing over to the 4-Fr system and (3) the reasons for changing over the 4-Fr system. TACE of the PHA (27 sessions), RHA/LHA (103 sessions), segmental (31 sessions), or subsegmental/sub-subsegmental arteries (162 sessions) was performed. The rate of successfully reaching the target artery using the 3.5-Fr system was 93% (306/328 sessions). We were unable to reach the target artery in 22 sessions, including 11/8/3 procedures targeting the sub-subsegmental artery, subsegmental artery, and RHA/LHA, respectively. We changed over to the 4-Fr system in six sessions; therefore, the rate of successful completion of the procedures without changing over to the 4-Fr system was 98% (322/328 sessions). TACE of the target artery can be successfully performed using the 3.5-Fr system in most patients with HCC.

  7. 9 CFR 351.6 - Official number.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Procedure for Obtaining Service: Administration of Program § 351.6 Official number. The Administrator will assign a certified technical animal fat... to identify all certified technical animal fat prepared or stored by the plant. ...

  8. 9 CFR 351.6 - Official number.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Procedure for Obtaining Service: Administration of Program § 351.6 Official number. The Administrator will assign a certified technical animal fat... to identify all certified technical animal fat prepared or stored by the plant. ...

  9. 9 CFR 351.6 - Official number.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Procedure for Obtaining Service: Administration of Program § 351.6 Official number. The Administrator will assign a certified technical animal fat... to identify all certified technical animal fat prepared or stored by the plant. ...

  10. 9 CFR 351.6 - Official number.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Procedure for Obtaining Service: Administration of Program § 351.6 Official number. The Administrator will assign a certified technical animal fat... to identify all certified technical animal fat prepared or stored by the plant. ...

  11. 9 CFR 351.6 - Official number.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR EXPORT Procedure for Obtaining Service: Administration of Program § 351.6 Official number. The Administrator will assign a certified technical animal fat... to identify all certified technical animal fat prepared or stored by the plant. ...

  12. 7 CFR 3203.4 - Procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., DEPARTMENT OF AGRICULTURE GUIDELINES FOR THE TRANSFER OF EXCESS COMPUTERS OR OTHER TECHNICAL EQUIPMENT..., in writing, an authorized official to approve transfers of excess computers or other technical...) Excess computers or other technical equipment must first be internally screened to ensure it is not...

  13. 7 CFR 3203.4 - Procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., DEPARTMENT OF AGRICULTURE GUIDELINES FOR THE TRANSFER OF EXCESS COMPUTERS OR OTHER TECHNICAL EQUIPMENT..., in writing, an authorized official to approve transfers of excess computers or other technical...) Excess computers or other technical equipment must first be internally screened to ensure it is not...

  14. Investigation of the factor structure of the Wechsler Adult Intelligence Scale--Fourth Edition (WAIS-IV): exploratory and higher order factor analyses.

    PubMed

    Canivez, Gary L; Watkins, Marley W

    2010-12-01

    The present study examined the factor structure of the Wechsler Adult Intelligence Scale--Fourth Edition (WAIS-IV; D. Wechsler, 2008a) standardization sample using exploratory factor analysis, multiple factor extraction criteria, and higher order exploratory factor analysis (J. Schmid & J. M. Leiman, 1957) not included in the WAIS-IV Technical and Interpretation Manual (D. Wechsler, 2008b). Results indicated that the WAIS-IV subtests were properly associated with the theoretically proposed first-order factors, but all but one factor-extraction criterion recommended extraction of one or two factors. Hierarchical exploratory analyses with the Schmid and Leiman procedure found that the second-order g factor accounted for large portions of total and common variance, whereas the four first-order factors accounted for small portions of total and common variance. It was concluded that the WAIS-IV provides strong measurement of general intelligence, and clinical interpretation should be primarily at that level.

  15. [Causes of vocal cord dyscinesia and its original factors after endotracheal intubation].

    PubMed

    Sun, Anke; Zhang, Tiezheng; Liu, Wenyuan; Tang, Weiwei; Guo, Xiaohong

    2012-03-01

    To research the causes of postintubation vocal cord dyskinesia and its contributing factors. The causes of vocal cord dyskinesia were confirmed by laryngoscope, three-dimensional spiral CT, stroboscope, and the analysis of therapy. The factors relevant to the causes of vocal cord dyskinesia were analysed based on the following elements: (1) the anatomic or pathological condition of patients or the technical skills of anesthetists. (2) emaciated or obese body and neck. (3) the age of patients. (4) the duration of endotracheal tube retention. (5) the types of operations. (6) anesthesia procedure. Among 135 patients, 128 cases (94.81%) manifested arytenoid dislocation, 7 cases (5.19%) vocal cord paralysis. The study showed that the vocal cord dyskinesia associated with anatomic or pathological condition of patients and technical skills of anesthetists (with intubation difficulty) accounted for 76.30%. The patients with relative emaciated body or neck accounted for 90.62% in cases without intubation difficulty. Age had no significant analytical relationship with vocal cord dyskinesia. Prolonged intubation (endotracheal tube retention over 12 hours) was accounted for only 17.64%. The incidence of vocal cord dyskinesia was nearly 0.5% in patients underwent cardio-thoracic surgery, accounting for 59.26% of all the patients. There are two major causes of vocal cord dyskinesia: arytenoid dislocation and vocal cord paralysis, and the rate of vocal cord dyskinesia could be reduced by the improvement of technical skill of anesthetists and/or sufficient attention to the intubation condition of patients.

  16. 77 FR 57196 - Proposed Collection; Comment Request for Revenue Procedure 2011-4, Revenue Procedure 2011-5...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-17

    ...) of the Internal Revenue Service to give advice on filing letter ruling, determination letter, and... Procedure 2011-4 (Letter Rulings), Revenue Procedure 2011-5 (Technical Advice), Revenue Procedure 2011-6... Advice), Revenue Procedure 2011-6 (Determination Letters), and Revenue Procedure 2011-8 (User Fees). OMB...

  17. Vertical ridge augmentation using an equine bone and collagen block infused with recombinant human platelet-derived growth factor-BB: a randomized single-masked histologic study in non-human primates.

    PubMed

    Nevins, Myron; Al Hezaimi, Khalid; Schupbach, Peter; Karimbux, Nadeem; Kim, David M

    2012-07-01

    This study tests the effectiveness of hydroxyapatite and collagen bone blocks of equine origin (eHAC), infused with recombinant human platelet-derived growth factor-BB (rhPDGF-BB), to augment localized posterior mandibular defects in non-human primates (Papio hamadryas). Bilateral critical-sized defects simulating severe atrophy were created at the time of the posterior teeth extraction. Test and control blocks (without growth factor) were randomly grafted into the respective sites in each non-human primate. All sites exhibited vertical ridge augmentation, with physiologic hard- and soft-tissue integration of the blocks when clinical and histologic examinations were done at 4 months after the vertical ridge augmentation procedure. There was a clear, although non-significant, tendency to increased regeneration in the test sites. As in the first two preclinical studies in this series using canines, experimental eHAC blocks infused with rhPDGF-BB proved to be a predictable and technically viable method to predictably regenerate bone and soft tissue in critical-sized defects. This investigation supplies additional evidence that eHAC blocks infused with rhPDGF-BB growth factor is a predictable and technically feasible option for vertical augmentation of severely resorbed ridges.

  18. Technical and Clinical Outcomes Following Colonic Stenting: A Seven-Year Analysis of 268 Procedures.

    PubMed

    Little, M W; Oakley, T; Briggs, J H; Sutcliffe, J A; Allouni, A K; Makris, G; Bratby, M J; Tapping, C R; Patel, R; Wigham, A; Anthony, S; Phillips-Hughes, J; Uberoi, R

    2016-10-01

    To assess the factors contributing to the technical and clinical success of colorectal stenting for large bowel obstruction. 268 cases of colonic stenting for large bowel obstruction were performed in 249 patients of mean age of 72 years (28-98) between 2006 and 2013. The majority of strictures were due to malignant disease, 244/268 (91 %). Diverticular strictures accounted for 24/268 (9 %). Overall technical success rate was 81 % (217/268), with a clinical success rate of 65 % (174/268). Duration of symptoms ranged from 0 to 180 days (mean 8 days). Technical success rate was seen to decrease with increasing symptom duration. For symptom duration of less than 1 week, technical success was 85.4 % (181/212) versus 69.6 % (39/56) for those with symptoms of greater than a week (p < 0.05). Clinical success rates fell from 71.3 % (107/150) to 59.3 % (70/118) (p < 0.05) when attempting to stent lesions of greater than 5 cm. There was also a significant reduction in clinical success when stenting lesions on a bend rather than a straight segment of colon 75.7 % (109/144) versus 59.7 % (74/124) (p < 0.05). A total of 20 (7.46 %) perforations were identified during the study. Stent migration occurred in 6.6 % of cases. In-stent stenosis occurred in 3.3 %. The overall 30-day all cause mortality rate was 9 %. Lesion size, location and duration of obstructive symptoms are statistically significant determinants of patient outcome. These factors could be used to advise patient selection for colonic stenting or direct progression to surgical intervention.

  19. 32 CFR 250.6 - Responsibilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... WITHHOLDING OF UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.6 Responsibilities. (a) The Under... technical data that may be withheld from public disclosure under this Directive. (5) Establish procedures to... with this Directive. (2) Disseminate and withhold from public disclosure technical data subject to this...

  20. 32 CFR 250.6 - Responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... WITHHOLDING OF UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.6 Responsibilities. (a) The Under... technical data that may be withheld from public disclosure under this Directive. (5) Establish procedures to... with this Directive. (2) Disseminate and withhold from public disclosure technical data subject to this...

  1. 32 CFR 250.6 - Responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... WITHHOLDING OF UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.6 Responsibilities. (a) The Under... technical data that may be withheld from public disclosure under this Directive. (5) Establish procedures to... with this Directive. (2) Disseminate and withhold from public disclosure technical data subject to this...

  2. 32 CFR 250.6 - Responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... WITHHOLDING OF UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.6 Responsibilities. (a) The Under... technical data that may be withheld from public disclosure under this Directive. (5) Establish procedures to... with this Directive. (2) Disseminate and withhold from public disclosure technical data subject to this...

  3. 32 CFR 250.6 - Responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... WITHHOLDING OF UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.6 Responsibilities. (a) The Under... technical data that may be withheld from public disclosure under this Directive. (5) Establish procedures to... with this Directive. (2) Disseminate and withhold from public disclosure technical data subject to this...

  4. 48 CFR 742.1170-2 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... policies, procedures, and limitations of this section do not apply to technical reports, studies, papers... section applies to USAID non-personal, professional/technical services contracts exceeding the simplified... FAR 48 CFR subpart 42.11 are compatible with the types of technical assistance contracts usually...

  5. 48 CFR 742.1170-2 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... policies, procedures, and limitations of this section do not apply to technical reports, studies, papers... section applies to USAID non-personal, professional/technical services contracts exceeding the simplified... FAR 48 CFR subpart 42.11 are compatible with the types of technical assistance contracts usually...

  6. 48 CFR 742.1170-2 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... policies, procedures, and limitations of this section do not apply to technical reports, studies, papers... section applies to USAID non-personal, professional/technical services contracts exceeding the simplified... FAR 48 CFR subpart 42.11 are compatible with the types of technical assistance contracts usually...

  7. TADS Needs Assessment Procedures Manual, Summer 1980.

    ERIC Educational Resources Information Center

    Black, Talbot; And Others

    The TADS (Technical Assistance Development System) Needs Assessment Manual is designed to guide the comprehensive review of Handicapped Children's Early Education Program (HCEEP) demonstration projects in identifying technical assistance needs. An introduction reviews the TADS technical assistance model which includes program planning, needs…

  8. Toolbox of assessment tools of technical skills in otolaryngology-head and neck surgery: A systematic review.

    PubMed

    Labbé, Mathilde; Young, Meredith; Nguyen, Lily H P

    2017-10-08

    To support the development of programs of assessment of technical skills in the operating room (OR), we systematically reviewed the literature to identify assessment tools specific to otolaryngology-head and neck surgery (OTL-HNS) core procedures and summarized their characteristics. We systematically searched Embase, MEDLINE, PubMed, and Cochrane to identify and report on assessment tools that can be used to assess residents' technical surgical skills in the operating room for OTL-HNS core procedures. Of the 736 unique titles retrieved, 16 articles met inclusion criteria, covering 11 different procedures (in otology, rhinology, laryngology, head and neck, and general otolaryngology). The tools were composed of a task-specific checklist and/or global rating scale and were developed in the OR, on human cadavers, or in a simulation setting. Our study reports on published tools for assessing technical skills for OTL-HNS residents during core procedures conducted in the OR. These assessment tools could facilitate the provision of timely feedback to trainees including specific goals for improvement. However, the paucity of publications suggests little agreement on how to best perform work-based direct-observation assessment for core surgical procedures in OTL-HNS. The sparsity of tools specific to OTL-HNS may become a barrier to a fluid transition to competency-based medical education. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  9. 34 CFR 86.302 - What are the procedures used by the Secretary for providing information or technical assistance?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... providing information or technical assistance? 86.302 Section 86.302 Education Office of the Secretary... information or technical assistance? (a) The Secretary provides information or technical assistance to an IHE in writing, through site visits, or by other means. (b) The IHE shall inform the Secretary of any...

  10. 32 CFR 250.1 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.1 Purpose. This part establishes policy, prescribes procedures, and assigns responsibilities for the dissemination and withholding of technical data. ...

  11. 32 CFR 250.1 - Purpose.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.1 Purpose. This part establishes policy, prescribes procedures, and assigns responsibilities for the dissemination and withholding of technical data. ...

  12. 32 CFR 250.1 - Purpose.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.1 Purpose. This part establishes policy, prescribes procedures, and assigns responsibilities for the dissemination and withholding of technical data. ...

  13. 32 CFR 250.1 - Purpose.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.1 Purpose. This part establishes policy, prescribes procedures, and assigns responsibilities for the dissemination and withholding of technical data. ...

  14. 32 CFR 250.1 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... UNCLASSIFIED TECHNICAL DATA FROM PUBLIC DISCLOSURE § 250.1 Purpose. This part establishes policy, prescribes procedures, and assigns responsibilities for the dissemination and withholding of technical data. ...

  15. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    PubMed

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  16. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices

    PubMed Central

    Kraft, Marc

    2008-01-01

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority. PMID:20204095

  17. Laparoscopic repair of inguinal hernia in adults

    PubMed Central

    Yang, Xue-Fei

    2016-01-01

    Laparoscopic repair of inguinal hernia is mini-invasive and has confirmed effects. The procedures include intraperitoneal onlay mesh (IPOM) repair, transabdominal preperitoneal (TAPP) repair and total extraperitoneal (TEP) repair. These procedures have totally different anatomic point of view, process and technical key points from open operations. The technical details of these operations are discussed in this article, also the strategies of treatment for some special conditions. PMID:27867954

  18. Procedural Influence on Internal and External Assessment Scores of Undergraduate Vocational and Technical Education Research Projects in Nigerian Universities

    ERIC Educational Resources Information Center

    A. C., John; Manabete, S. S.

    2015-01-01

    This study sought to determine the procedural influence on internal and external assessment scores of undergraduate research projects in vocational and technical education programmes in the university under study. A survey research design was used for the conduct of this study. The population consisted of 130 lecturers and 1,847 students in the…

  19. Productivity change of surgeons in an academic year.

    PubMed

    Nakata, Yoshinori; Watanabe, Yuichi; Otake, Hiroshi; Nakamura, Toshihito; Oiso, Giichiro; Sawa, Tomohiro

    2015-01-01

    The goal of this study was to calculate total factor productivity of surgeons in an academic year and to evaluate the effect of surgical trainees on their productivity. We analyzed all the surgical procedures performed from April 1 through September 30, 2013 in the Teikyo University Hospital. The nonradial and nonoriented Malmquist model under the variable returns-to-scale assumptions was employed. A decision-making unit is defined as a surgeon with the highest academic rank in the surgery. Inputs were defined as the number of physicians who assisted in surgery, and the time of surgical operation from skin incision to skin closure. The output was defined as the surgical fee for each surgery. April is the beginning month of a new academic year in Japan, and we divided the study period into April to June and July to September 2013. We computed each surgeon's Malmquist index, efficiency change, and technical change. We analyzed 2789 surgical procedures that were performed by 105 surgeons. The Malmquist index of all surgeons was significantly greater than 1 (p = 0.0033). The technical change was significantly greater than 1 (p < 0.0001). However, the efficiency change was not statistically significantly different from 1 (p = 0.1817). The surgeons are less productive in the beginning months of a new academic year. The main factor of this productivity loss is considered to be surgical training. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  20. 29 CFR 95.44 - Procurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., record of past performance, financial and technical resources or accessibility to other necessary..., whenever practicable, of technical requirements in terms of functions to be performed or performance...

  1. 15 CFR 14.44 - Procurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., record of past performance, financial and technical resources or accessibility to other necessary... practicable, of technical requirements in terms of functions to be performed or performance required...

  2. Simulator-Based Angiography and Endovascular Neurosurgery Curriculum: A Longitudinal Evaluation of Performance Following Simulator-Based Angiography Training.

    PubMed

    Pannell, J Scott; Santiago-Dieppa, David R; Wali, Arvin R; Hirshman, Brian R; Steinberg, Jeffrey A; Cheung, Vincent J; Oveisi, David; Hallstrom, Jon; Khalessi, Alexander A

    2016-08-29

    This study establishes performance metrics for angiography and neuroendovascular surgery procedures based on longitudinal improvement in individual trainees with differing levels of training and experience. Over the course of 30 days, five trainees performed 10 diagnostic angiograms, coiled 10 carotid terminus aneurysms in the setting of subarachnoid hemorrhage, and performed 10 left middle cerebral artery embolectomies on a Simbionix Angio Mentor™ simulator. All procedures were nonconsecutive. Total procedure time, fluoroscopy time, contrast dose, heart rate, blood pressures, medications administered, packing densities, the number of coils used, and the number of stent-retriever passes were recorded. Image quality was rated, and the absolute value of technically unsafe events was recorded. The trainees' device selection, macrovascular access, microvascular access, clinical management, and the overall performance of the trainee was rated during each procedure based on a traditional Likert scale score of 1=fail, 2=poor, 3=satisfactory, 4=good, and 5=excellent. These ordinal values correspond with published assessment scales on surgical technique. After performing five diagnostic angiograms and five embolectomies, all participants demonstrated marked decreases in procedure time, fluoroscopy doses, contrast doses, and adverse technical events; marked improvements in image quality, device selection, access scores, and overall technical performance were additionally observed (p < 0.05). Similarly, trainees demonstrated marked improvement in technical performance and clinical management after five coiling procedures (p < 0.05). However, trainees with less prior experience deploying coils continued to experience intra-procedural ruptures up to the eighth embolization procedure; this observation likely corresponded with less tactile procedural experience to an exertion of greater force than appropriate for coil placement. Trainees across all levels of training and prior experience demonstrated a significant performance improvement after completion of our simulator curriculum consisting of five diagnostic angiograms, five embolectomy cases, and 10 aneurysm coil embolizations.

  3. 48 CFR 227.7108 - Contractor data repositories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Technical Data 227.7108 Contractor data repositories. (a) Contractor data repositories may be established... procedures for protecting technical data delivered to or stored at the repository from unauthorized release... disclosure of technical data from the repository to third parties consistent with the Government's rights in...

  4. 48 CFR 715.303-70 - Responsibilities of USAID evaluation committees.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... evaluation committees. A technical evaluation committee shall be established for each proposed procurement. In each case, the committee shall be composed of a chair representing the cognizant technical office... representatives from other concerned offices as appropriate. (b) Technical evaluation procedures. (1) The...

  5. 75 FR 12740 - Wyoming Interstate Company, Inc.; Notice of Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ... additional technical, engineering, and operational support for its proposed gas quality allocation procedures... should be prepared to support its position with adequate technical, engineering, and operational information. FERC conferences are accessible under section 508 of the Rehabilitation Act of 1973. For...

  6. Providing Services to Virtual Patrons.

    ERIC Educational Resources Information Center

    Hulshof, Robert

    1999-01-01

    Discusses the types of services libraries need to support patrons who access the library via the Internet or e-mail. Highlights include issues in technical support; establishing policies and procedures; tools for technical support, including hardware and software; impacts of technical support on staff; and future possibilities. (LRW)

  7. Technical results and effects of operator experience on uterine artery embolization for fibroids: the Ontario Uterine Fibroid Embolization Trial.

    PubMed

    Pron, Gaylene; Bennett, John; Common, Andrew; Sniderman, Kenneth; Asch, Murray; Bell, Stuart; Kozak, Roman; Vanderburgh, Leslie; Garvin, Greg; Simons, Martin; Tran, Cuong; Kachura, John

    2003-05-01

    To document the technical results and spectrum of practice of uterine artery embolization (UAE) for fibroids in the health care setting in Canada. The effects of interventional radiologist's (IR's) experience with UAE on procedure and fluoroscopy time were also investigated. The study involved a multicenter prospective single-arm clinical treatment trial and included the practices of 11 IRs at eight university-affiliated teaching and community hospitals. Vascular access with percutaneous femoral artery approach was followed by transcatheter delivery of polyvinyl alcohol (PVA) particles into uterine arteries with fluoroscopic guidance. Technical success, complications, procedural time, fluoroscopy time, and effects of operator experience were outcomes analyzed. Between November 1998 and November 2000, 570 embolization procedures were performed in 555 patients. UAE was bilaterally successful in 97% (95% CI: 95%-98%). Variant anatomy was the most common reason for failure to embolize bilaterally. The procedural complication rate was 5.3% (95% CI: 3.6%-7.4%). Of the 30 events, three involved major complications (one seizure and two allergic reactions) that resulted in additional care or extended hospital stay. Procedure time and fluoroscopy time averaged 61 minutes (95% CI; 58-63 minutes) and 18.9 minutes (95% CI; 18-19.8) and varied significantly among IRs (P <.001; P <.001). The average 27% reduction in procedure time (20 minutes; P <.001) and 24% reduction in fluoroscopy time (5.1 minutes; P <.001) with increasing UAE experience were significant. A high level of technical success with few complications was obtained with a variety of operators in diverse practice settings. Increased experience in UAE significantly reduced procedure and fluoroscopy time.

  8. Investment alternative: the status quo or PACS?

    NASA Astrophysics Data System (ADS)

    Vanden Brink, John A.; Cywinski, Jozef K.

    1990-08-01

    While the cost of Picture Archiving and Communication Systems (PACS) can be substantial, the cost of continuing with present manual methods may become prohibitive in growing departments as the need for additional space and personnel (both technical and professional) to meet the increasing requirements for all image management activities continues to grow. This will occur simultaneously with increasing pressures on problems of the present system, i.e., lost films, lost revenues, delayed reporting and longer diagnostic cycle times. Present methods of image archiving communication and management i.e. the relationship of procedure volume to VFE requirements for professional and technical personnel, costs of film, film storage space, and other performance factors are analyzed based on the database created by the Technology Marketing Group (TMG) computerized cost analysis model applied to over 50 US hospitals. Also, the model is used to provide the projected cost of present methods of film management for an average US 400 +bed hospital based on ten year growth rate assumptions. TMG PACS Tracking data provides confirmation of staffmg pattern correlation to procedure volume. The data presented in the paper provides a basis for comparing the investment in maintaining the status quo to an investment in PACS.

  9. Morphologic Characteristics and Relating Factors to the Need of Technical Modification in Transcatheter Closure of Large Atrial Septal Defect (≥25 mm)

    PubMed Central

    Park, Su-Jin; Kim, Nam Kyun; Kim, Jung Ok; Yoo, Byung Won; Sul, Jun Hee

    2010-01-01

    Background and Objectives The rigid coupling between the delivery wire and the right atrial disk has been occasionally encountered during transcatheter closure of atrial septal defect (ASD). Therefore the device frequently makes a perpendicular angle, and the leading edge of left atrial disk slips through the defect and prolapses into right atrium (RA) before it is properly placed in the septum. The purpose of this study is to investigate relating factors to the need of technical modification in transcatheter closure of large ASD and to evaluate relevant morphologic characteristics of atrial septal rim in this situation. Subjects and Methods From July, 2003 to May, 2007, 312 patients underwent transcatheter occlusion of ASD with Amplatzer Septal Occluder® (ASO, AGA medical corporation, Golden Valley, MN, USA) at Yonsei Cardiovascular Center and among them 109 patients had large ASD (≥25 mm) and these patients were enrolled in our study. Patients were divided into two groups according to the deploying methods of the device (Group I: standard method, Group II: modified methods). Assessments of the defects and its surrounding rims were made by echocardiography. Results There were no differences between 2 groups in age, body weight and height except for balloon-stretched diameter (stop-flow technique) and device size. Group II patients with modified methods showed larger balloon-stretched diameter and device size than group I patients with standard method. The mean length of anterosuperior (AS) rim in group II was significantly shorter than group I (p<0.05). As the size of the device used in procedure increased, there was a trend towards increase in the need of modified methods. Conclusion This study shows that AS rim deficiency and the size of ASD may be the relating factors to the need of technical modification in transcatheter closure of ASD. Therefore, when the initial try with standard method is not successful in large ASD with deficient AS rim, we suggest that changing strategy of implantation may save time and efforts and possibly reduce the risk of complications associated with prolonged procedure. PMID:20421960

  10. Small scale rainfall simulators: Challenges for a future use in soil erosion research

    NASA Astrophysics Data System (ADS)

    Ries, Johannes B.; Iserloh, Thomas; Seeger, Manuel

    2013-04-01

    Rainfall simulation on micro-plot scale is a method used worldwide to assess the generation of overland flow, soil erosion, infiltration and interrelated processes such as soil sealing, crusting, splash and redistribution of solids and solutes. The produced data are of great significance not only for the analysis of the simulated processes, but also as a source of input-data for soil erosion modelling. The reliability of the data is therefore of paramount importance, and quality management of rainfall simulation procedure a general responsibility of the rainfall simulation community. This was an accepted outcome at the "International Rainfall Simulator Workshop 2011" at Trier University. The challenges of the present and near future use of small scale rainfall simulations concern the comparability of results and scales, the quality of the data for soil erosion modelling, and further technical developments to overcome physical limitations and constraints. Regarding the high number of research questions, different fields of application, and due to the great technical creativity of researchers, a large number of different types of rainfall simulators is available. But each of the devices produces a different rainfall, leading to different kinetic energy values influencing soil surface and erosion processes. Plot sizes are also variable, as well as the experimental simulation procedures. As a consequence, differing runoff and erosion results are produced. The presentation summarises the three important aspects of rainfall simulations, following a processual order: 1. Input-factor "rain" and its calibration 2. Surface-factor "plot" and its documentation 3. Output-factors "runoff" and "sediment concentration" Finally, general considerations about the limitations and challenges for further developments and applications of rainfall simulation data are presented.

  11. Adrenal vein sampling: substantial need for technical improvement at regional referral centres.

    PubMed

    Elliott, Panda; Holmes, Daniel T

    2013-10-01

    Adrenal vein sampling (AVS) is the gold standard for localization of aldosterone producing adenoma. The anatomy of the right adrenal vein makes this procedure technically demanding and it may yield no clinical information if the adrenal veins are not adequately cannulated. Having frequently observed the technical failure of AVS, we undertook a review of 220 procedures in British Columbia, Canada. Subjects were retrospectively identified through the laboratory information system. The following were collected: demographics, screening aldosterone concentration and renin activity/mass, results of dynamic function tests, AVS aldosterone and cortisol results. Standard calculations were performed on AVS data and site-specific success rates were compared. The effect of adrenocorticotropin hormone (ACTH) stimulation on the selectivity index (SI) and lateralization index (LI) were explored. The overall technical success-rate of AVS procedures was only 44% in procedures where no ACTH-stimulation was used (n=200) but this rose significantly (p<0.01) to 82% for those employing ACTH (n=139). ACTH-stimulation significantly increased the median SI (left: 5.8 vs 36.7, p<0.01; right: 7.0 vs 51.2, p<0.01), and salvaged 36 procedures from yielding no information, 21 of which demonstrated lateralization of aldosterone production. In 64 cases showing lateralization both pre and post-stimulation, ACTH significantly decreased the median LI from 5.4 to 2.2, p<0.01, creating substantial risk for spurious loss of lateralization. The technical success of AVS is lower than reported elsewhere. Provided that effects on the LI are considered, the use of ACTH-stimulation during AVS assists in the identification of unilateral forms of PA. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Transesophageal echocardiography and intracardiac echocardiography differently predict potential technical challenges or failures of interatrial shunts catheter-based closure.

    PubMed

    Rigatelli, Gianluca; Rigateli, Gianluca; Cardaioli, Paolo; Braggion, Gabriele; Aggio, Silvio; Giordan, Massimo; Magro, Beatrice; Nascimben, Alberto; Favaro, Alberto; Roncon, Loris; Rincon, Loris

    2007-02-01

    We sought to prospectively assess the role of transesophageal (TEE) and intracardiac echocardiography (ICE) in detecting potential technical difficulties or failures in patients submitted to interatrial shunts percutaneous closure. We prospectively enrolled 46 consecutive patients (mean age 35+/-28, 8 years, 30 female) referred to our center for catheter-based closure of interatrial shunts. All patients were screened with TEE before the intervention. Patients who met the inclusion criteria underwent ICE study before the closure attempt (40 patients). TEE detected potential technical difficulties in 22.5% (9/40) patients, whereas ICE detected technical difficulties in 32.5% (13/40 patients). In patients with positive TEE/ICE the procedural success (92.4% versus 100% and, P = ns) and follow-up failure rate (7.7% versus 0%, P = ns) were similar to patients with negative TEE/ICE, whereas the fluoroscopy time (7 +/- 1.2 versus 5 +/- 0.7 minutes, P < 0.03), the procedural time (41 +/- 4.1 versus 30 +/- 8.2 minutes, P +/- 0.03), and technical difficulties rate (23.1% versus 0%, P = 0.013) were higher. Differences between ICE and TEE in the evaluation of rims, measurement of ASD or fossa ovalis, and detection of venous valve and embryonic septal membrane remnants impacted on technical challenges and on procedural and fluoroscopy times but did not influence the success rate and follow-up failure rate.

  13. 47 CFR 68.7 - Technical criteria for terminal equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK General § 68.7 Technical criteria for... switched telephone network. (b) Technical criteria published by the Administrative Council for Terminal... network from harms caused by the connection of terminal equipment, subject to the appeal procedures in...

  14. 47 CFR 68.7 - Technical criteria for terminal equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK General § 68.7 Technical criteria for... switched telephone network. (b) Technical criteria published by the Administrative Council for Terminal... network from harms caused by the connection of terminal equipment, subject to the appeal procedures in...

  15. Scaffolding Collaborative Technical Writing with Procedural Facilitation and Synchronous Discussion

    ERIC Educational Resources Information Center

    Yeh, Shiou-Wen; Lo, Jia-Jiunn; Huang, Jeng-Jia

    2011-01-01

    With the advent of computer technology, researchers and instructors are attempting to devise computer support for effective collaborative technical writing. In this study, a computer-supported environment for collaborative technical writing was developed. This system (Process-Writing Wizard) provides process-oriented scaffolds and a synchronous…

  16. The 1996 NAEP Technical Report.

    ERIC Educational Resources Information Center

    Allen, Nancy L.; Carlson, James E.; Zelenak, Christine A.

    This report documents the design, administration, and data analysis procedure of the National Assessment of Education Progress (NAEP) for 1996. It indicates the technical decisions that were made and the rationale behind them. Detailed substantive findings are not presented in this report. These chapters provide technical information about the…

  17. The Aristotle score: a complexity-adjusted method to evaluate surgical results.

    PubMed

    Lacour-Gayet, F; Clarke, D; Jacobs, J; Comas, J; Daebritz, S; Daenen, W; Gaynor, W; Hamilton, L; Jacobs, M; Maruszsewski, B; Pozzi, M; Spray, T; Stellin, G; Tchervenkov, C; Mavroudis And, C

    2004-06-01

    Quality control is difficult to achieve in Congenital Heart Surgery (CHS) because of the diversity of the procedures. It is particularly needed, considering the potential adverse outcomes associated with complex cases. The aim of this project was to develop a new method based on the complexity of the procedures. The Aristotle project, involving a panel of expert surgeons, started in 1999 and included 50 pediatric surgeons from 23 countries, representing the EACTS, STS, ECHSA and CHSS. The complexity was based on the procedures as defined by the STS/EACTS International Nomenclature and was undertaken in two steps: the first step was establishing the Basic Score, which adjusts only the complexity of the procedures. It is based on three factors: the potential for mortality, the potential for morbidity and the anticipated technical difficulty. A questionnaire was completed by the 50 centers. The second step was the development of the Comprehensive Aristotle Score, which further adjusts the complexity according to the specific patient characteristics. It includes two categories of complexity factors, the procedure dependent and independent factors. After considering the relationship between complexity and performance, the Aristotle Committee is proposing that: Performance = Complexity x Outcome. The Aristotle score, allows precise scoring of the complexity for 145 CHS procedures. One interesting notion coming out of this study is that complexity is a constant value for a given patient regardless of the center where he is operated. The Aristotle complexity score was further applied to 26 centers reporting to the EACTS congenital database. A new display of centers is presented based on the comparison of hospital survival to complexity and to our proposed definition of performance. A complexity-adjusted method named the Aristotle Score, based on the complexity of the surgical procedures has been developed by an international group of experts. The Aristotle score, electronically available, was introduced in the EACTS and STS databases. A validation process evaluating its predictive value is being developed.

  18. The history of head transplantation: a review.

    PubMed

    Lamba, Nayan; Holsgrove, Daniel; Broekman, Marike L

    2016-12-01

    Since the turn of the last century, the prospect of head transplantation has captured the imagination of scientists and the general public. Recently, head transplant has regained attention in popular media, as neurosurgeons have proposed performing this procedure in 2017. Given the potential impact of such a procedure, we were interested in learning the history of the technical hurdles that need to be overcome, and determine if it is even technically possible to perform such a procedure on humans today. We conducted a historical review of available literature on the technical challenges and developments of head transplantation. The many social, psychological, ethical, religious, cultural, and legal questions of head transplantation were beyond the scope of this review. Our historical review identified the following important technical considerations related to performing a head transplant: maintenance of blood flow to an isolated brain via vessel anastomosis; availability of immunosuppressive agents; spinal anastomosis and fusion following cord transfection; pain control in the recipient. Several animal studies have demonstrated success in maintaining recipient cerebral perfusion and achieving immunosuppression. However, there is currently sparse evidence in favor of successful spinal anastomosis and fusion after transection. While recent publications by an Italian group offer novel approaches to this challenge, research on this topic has been sparse and hinges on procedures performed in animal models in the 1970s. How transferrable these older methods are to the human nervous system is unclear and warrants further exploration. Our review identified several important considerations related to performing a viable head transplantation. Besides the technical challenges that remain, there are important ethical issues to consider, such as exploitation of vulnerable patients and informed consent. Thus, besides the remaining technical challenges, these ethical issues will also need to be addressed before moving these studies to the clinic.

  19. 45 CFR 2543.44 - Procurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., record of past performance, financial and technical resources or accessibility to other necessary... technical requirements in terms of functions to be performed or performance required, including the range of...

  20. 36 CFR 1210.44 - Procurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., record of past performance, financial and technical resources or accessibility to other necessary... technical requirements in terms of functions to be performed or performance required, including the range of...

  1. 14 CFR 1260.144 - Procurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., record of past performance, financial and technical resources or accessibility to other necessary... technical requirements in terms of functions to be performed or performance required, including the range of...

  2. Statistical Analysis of Complexity Generators for Cost Estimation

    NASA Technical Reports Server (NTRS)

    Rowell, Ginger Holmes

    1999-01-01

    Predicting the cost of cutting edge new technologies involved with spacecraft hardware can be quite complicated. A new feature of the NASA Air Force Cost Model (NAFCOM), called the Complexity Generator, is being developed to model the complexity factors that drive the cost of space hardware. This parametric approach is also designed to account for the differences in cost, based on factors that are unique to each system and subsystem. The cost driver categories included in this model are weight, inheritance from previous missions, technical complexity, and management factors. This paper explains the Complexity Generator framework, the statistical methods used to select the best model within this framework, and the procedures used to find the region of predictability and the prediction intervals for the cost of a mission.

  3. 21 CFR 1271.47 - What procedures must I establish and maintain?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.47 What procedures... technical manual prepared by another organization, provided that you have verified that the procedures are...

  4. Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paik, Nam Chull, E-mail: pncspine@gmail.com

    2016-07-15

    PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median proceduralmore » times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.« less

  5. Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Rodt, Thomas, E-mail: rodt.thomas@mh-hannover.de; Rosenthal, Herbert, E-mail: rosenthal.herbert@mh-hannover.de

    PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successfulmore » TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.« less

  6. Relationship between intraoperative non-technical performance and technical events in bariatric surgery.

    PubMed

    Fecso, A B; Kuzulugil, S S; Babaoglu, C; Bener, A B; Grantcharov, T P

    2018-03-30

    The operating theatre is a unique environment with complex team interactions, where technical and non-technical performance affect patient outcomes. The correlation between technical and non-technical performance, however, remains underinvestigated. The purpose of this study was to explore these interactions in the operating theatre. A prospective single-centre observational study was conducted at a tertiary academic medical centre. One surgeon and three fellows participated as main operators. All patients who underwent a laparoscopic Roux-en-Y gastric bypass and had the procedures captured using the Operating Room Black Box ® platform were included. Technical assessment was performed using the Objective Structured Assessment of Technical Skills and Generic Error Rating Tool instruments. For non-technical assessment, the Non-Technical Skills for Surgeons (NOTSS) and Scrub Practitioners' List of Intraoperative Non-Technical Skills (SPLINTS) tools were used. Spearman rank-order correlation and N-gram statistics were conducted. Fifty-six patients were included in the study and 90 procedural steps (gastrojejunostomy and jejunojejunostomy) were analysed. There was a moderate to strong correlation between technical adverse events (r s  = 0·417-0·687), rectifications (r s  = 0·380-0·768) and non-technical performance of the surgical and nursing teams (NOTSS and SPLINTS). N-gram statistics showed that after technical errors, events and prior rectifications, the staff surgeon and the scrub nurse exhibited the most positive non-technical behaviours, irrespective of operator (staff surgeon or fellow). This study demonstrated that technical and non-technical performances are related, on both an individual and a team level. Valuable data can be obtained around intraoperative errors, events and rectifications. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  7. 19 CFR 115.30 - Technical requirements for containers by design type.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.30 Technical... 19 Customs Duties 1 2011-04-01 2011-04-01 false Technical requirements for containers by design...

  8. 19 CFR 115.30 - Technical requirements for containers by design type.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.30 Technical... 19 Customs Duties 1 2012-04-01 2012-04-01 false Technical requirements for containers by design...

  9. 19 CFR 115.30 - Technical requirements for containers by design type.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.30 Technical... 19 Customs Duties 1 2014-04-01 2014-04-01 false Technical requirements for containers by design...

  10. 19 CFR 115.30 - Technical requirements for containers by design type.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.30 Technical... 19 Customs Duties 1 2010-04-01 2010-04-01 false Technical requirements for containers by design...

  11. 19 CFR 115.30 - Technical requirements for containers by design type.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.30 Technical... 19 Customs Duties 1 2013-04-01 2013-04-01 false Technical requirements for containers by design...

  12. 78 FR 48407 - Defense Federal Acquisition Regulation Supplement: Clauses With Alternates-Quality Assurance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or...

  13. Use of an Objective Structured Assessment of Technical Skill After a Sports Medicine Rotation.

    PubMed

    Dwyer, Tim; Slade Shantz, Jesse; Kulasegaram, Kulamakan Mahan; Chahal, Jaskarndip; Wasserstein, David; Schachar, Rachel; Devitt, Brian; Theodoropoulos, John; Hodges, Brian; Ogilvie-Harris, Darrell

    2016-12-01

    The purpose of this study was to determine if the use of an Objective Structured Assessment of Technical skill (OSATS), using dry models, would be a valid method of assessing residents' ability to perform sports medicine procedures after training in a competency-based model. Over 18 months, 27 residents (19 junior [postgraduate year (PGY) 1-3] and 8 senior [PGY 4-5]) sat the OSATS after their rotation, in addition to 14 sports medicine staff and fellows. Each resident was provided a list of 10 procedures in which they were expected to show competence. At the end of the rotation, each resident undertook an OSATS composed of 6 stations sampled from the 10 procedures using dry models-faculty used the Arthroscopic Surgical Skill Evaluation Tool (ASSET), task-specific checklists, as well as an overall 5-point global rating scale (GRS) to score each resident. Each procedure was videotaped for blinded review. The overall reliability of the OSATS (0.9) and the inter-rater reliability (0.9) were both high. A significant difference by year in training was seen for the overall GRS, the total ASSET score, and the total checklist score, as well as for each technical procedure (P < .001). Further analysis revealed a significant difference in the total ASSET score between junior (mean 18.4, 95% confidence interval [CI] 16.8 to 19.9) and senior residents (24.2, 95% CI 22.7 to 25.6), senior residents and fellows (30.1, 95% CI 28.2 to 31.9), as well as between fellows and faculty (37, 95% CI 36.1 to 27.8) (P < .05). The results of this study show that an OSATS using dry models shows evidence of validity when used to assess performance of technical procedures after a sports medicine rotation. However, junior residents were not able to perform as well as senior residents, suggesting that overall surgical experience is as important as intensive teaching. As postgraduate medical training shifts to a competency-based model, methods of assessing performance of technical procedures become necessary. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. The utility of live video capture to enhance debriefing following transcatheter aortic valve replacement.

    PubMed

    Seamans, David P; Louka, Boshra F; Fortuin, F David; Patel, Bhavesh M; Sweeney, John P; Lanza, Louis A; DeValeria, Patrick A; Ezrre, Kim M; Ramakrishna, Harish

    2016-10-01

    The surgical and procedural specialties are continually evolving their methods to include more complex and technically difficult cases. These cases can be longer and incorporate multiple teams in a different model of operating room synergy. Patients are frequently older, with comorbidities adding to the complexity of these cases. Recording of this environment has become more feasible recently with advancement in video and audio capture systems often used in the simulation realm. We began using live capture to record a new procedure shortly after starting these cases in our institution. This has provided continued assessment and evaluation of live procedures. The goal of this was to improve human factors and situational challenges by review and debriefing. B-Line Medical's LiveCapture video system was used to record successive transcatheter aortic valve replacement (TAVR) procedures in our cardiac catheterization/laboratory. An illustrative case is used to discuss analysis and debriefing of the case using this system. An illustrative case is presented that resulted in long-term changes to our approach of these cases. The video capture documented rare events during one of our TAVR procedures. Analysis and debriefing led to definitive changes in our practice. While there are hurdles to the use of this technology in every institution, the role for the ongoing use of video capture, analysis, and debriefing may play an important role in the future of patient safety and human factors analysis in the operating environment.

  15. The utility of live video capture to enhance debriefing following transcatheter aortic valve replacement

    PubMed Central

    Seamans, David P.; Louka, Boshra F.; Fortuin, F. David; Patel, Bhavesh M.; Sweeney, John P.; Lanza, Louis A.; DeValeria, Patrick A.; Ezrre, Kim M.; Ramakrishna, Harish

    2016-01-01

    Background: The surgical and procedural specialties are continually evolving their methods to include more complex and technically difficult cases. These cases can be longer and incorporate multiple teams in a different model of operating room synergy. Patients are frequently older, with comorbidities adding to the complexity of these cases. Recording of this environment has become more feasible recently with advancement in video and audio capture systems often used in the simulation realm. Aims: We began using live capture to record a new procedure shortly after starting these cases in our institution. This has provided continued assessment and evaluation of live procedures. The goal of this was to improve human factors and situational challenges by review and debriefing. Setting and Design: B-Line Medical's LiveCapture video system was used to record successive transcatheter aortic valve replacement (TAVR) procedures in our cardiac catheterization/laboratory. An illustrative case is used to discuss analysis and debriefing of the case using this system. Results and Conclusions: An illustrative case is presented that resulted in long-term changes to our approach of these cases. The video capture documented rare events during one of our TAVR procedures. Analysis and debriefing led to definitive changes in our practice. While there are hurdles to the use of this technology in every institution, the role for the ongoing use of video capture, analysis, and debriefing may play an important role in the future of patient safety and human factors analysis in the operating environment. PMID:27762242

  16. Dimensions of patient satisfaction with comprehensive abortion care in Addis Ababa, Ethiopia.

    PubMed

    Mossie Chekol, Bekalu; Abera Abdi, Dame; Andualem Adal, Tamirie

    2016-12-07

    Patient satisfaction is a measure of the extent to which a patient is content with the health care received from health care providers. It has been recognized as one of the most vital indicators of quality. Hence, it has been studied and measured extensively as part of service quality and as a standalone construct. In spite of this, there has been limited or no studies in Ethiopia that describe factors of abortion care contributed to women's satisfaction. This study aimed to identifying the underlying factors that contribute to patient satisfaction with comprehensive abortion care and at exploring relationships between total satisfaction scores and socio-demographic and care-related variables in Addis Ababa, Ethiopia. At the beginning of the study in-depth interviews with 16 participants and a focus group discussion of 8 participants were conducted consecutively at the time of discharge to generate questions used to evaluate women's satisfaction with abortion care. Following generation of the perceived indicators, expert review, pilot study, and item analysis were performed in order to produce the reduced and better 26 items used to measure abortion care satisfaction. A total sample size of 450 participants from eight health facilities completed the survey. Principal component exploratory factor analysis and confirmatory factor analysis were conducted respectively to identify and confirm the factors of abortion care contributing to women's satisfaction. Mean satisfaction scores were compared across socio demographic and care-related variables such as age, educational level, gestational age (first trimester and second trimester), and facility type using analysis of variance. Exploratory factor analysis of the 26 items indicated that satisfaction with abortion care consisted of five main components accounting for 60.48% of the variance in total satisfaction scores. Factor loadings of all items were found to be greater than 0.4. These factors are named as follows: "art of care" which means interpersonal relationships with the care-provider, "physical environment" which means the perceived quality of physical surroundings in which care is delivered, including cleanliness of facilities and equipment, "information" which means the information received related to abortion procedures, "privacy and confidentiality", "quality of care" which refers to technical quality of the care provider. Furthermore, analysis of variance showed that overall satisfaction is found to be related to facility type, relationship status, gestational age, and procedural type. The findings provided support that women's satisfaction with comprehensive abortion care has five major factors. Therefore, to improve the overall quality of comprehensive abortion care, attention should be given to the advancement of these components namely, positive interpersonal communication with care-receiver, pleasantness of physical environment, offering enough information related to the procedure, securing clients' privacy during counseling and treatment, and technical quality of the providers.

  17. Feasibility and safety of transfemoral intra-arterial chemotherapy for head and neck cancer using a 3-French catheter system: comparison with a 4-French catheter system.

    PubMed

    Watanabe, Shigeru; Yamamoto, Akira; Torigoe, Teruyuki; Kanki, Akihiko; Tamada, Tsutomu; Ito, Katsuyoshi

    2016-02-01

    To assess the technical feasibility of transfemoral intra-arterial chemotherapy for head and neck cancer using a 3-French catheter system (3-Fr). Sixty-two patients with head and neck cancer who underwent transfemoral intra-arterial chemotherapy were included in this study. Thirty-three patients underwent treatment using a 3-Fr (group 3-Fr). Twenty-nine patients underwent treatment using a 4-French catheter system (group 4-Fr). The technical success rate, duration of the procedure with fluoroscopy, and rate of procedure-related complications were compared between group 3-Fr and group 4-Fr. In addition, in group 3-Fr, bleeding at the puncture site after 1.5 h of bed rest was evaluated. The technical success rate was 100% in both groups. The duration of the procedure with fluoroscopy didn't differ between group 3-Fr (mean 28.0 min) and group 4-Fr (mean 30.2 min) (p = 0.524). There was no procedure-related complication in either group. In group 3-Fr, no hemorrhagic complication was observed. A 3-French catheter system can be used to perform transfemoral intra-arterial chemotherapy for head and neck cancer and is technically feasible with approximately the same duration of the procedure with fluoroscopy. Furthermore, this method may shorten the bed rest time without hemorrhagic complication, and may reduce the risk of pulmonary embolism.

  18. Learning curves for transapical transcatheter aortic valve replacement in the PARTNER-I trial: Technical performance, success, and safety.

    PubMed

    Suri, Rakesh M; Minha, Sa'ar; Alli, Oluseun; Waksman, Ron; Rihal, Charanjit S; Satler, Lowell P; Greason, Kevin L; Torguson, Rebecca; Pichard, Augusto D; Mack, Michael; Svensson, Lars G; Rajeswaran, Jeevanantham; Lowry, Ashley M; Ehrlinger, John; Mick, Stephanie L; Tuzcu, E Murat; Thourani, Vinod H; Makkar, Raj; Holmes, David; Leon, Martin B; Blackstone, Eugene H

    2016-09-01

    Introduction of hybrid techniques, such as transapical transcatheter aortic valve replacement (TA-TAVR), requires skills that a heart team must master to achieve technical efficiency: the technical performance learning curve. To date, the learning curve for TA-TAVR remains unknown. We therefore evaluated the rate at which technical performance improved, assessed change in occurrence of adverse events in relation to technical performance, and determined whether adverse events after TA-TAVR were linked to acquiring technical performance efficiency (the learning curve). From April 2007 to February 2012, 1100 patients, average age 85.0 ± 6.4 years, underwent TA-TAVR in the PARTNER-I trial. Learning curves were defined by institution-specific patient sequence number using nonlinear mixed modeling. Mean procedure time decreased from 131 to 116 minutes within 30 cases (P = .06) and device success increased to 90% by case 45 (P = .0007). Within 30 days, 354 patients experienced a major adverse event (stroke in 29, death in 96), with possibly decreased complications over time (P ∼ .08). Although longer procedure time was associated with more adverse events (P < .0001), these events were associated with change in patient risk profile, not the technical performance learning curve (P = .8). The learning curve for TA-TAVR was 30 to 45 procedures performed, and technical efficiency was achieved without compromising patient safety. Although fewer patients are now undergoing TAVR via nontransfemoral access, understanding TA-TAVR learning curves and their relationship with outcomes is important as the field moves toward next-generation devices, such as those to replace the mitral valve, delivered via the left ventricular apex. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. The financial implications of endovascular aneurysm repair in the cost containment era.

    PubMed

    Stone, David H; Horvath, Alexander J; Goodney, Philip P; Rzucidlo, Eva M; Nolan, Brian W; Walsh, Daniel B; Zwolak, Robert M; Powell, Richard J

    2014-02-01

    Endovascular aneurysm repair (EVAR) is associated with significant direct device costs. Such costs place EVAR at odds with efforts to constrain healthcare expenditures. This study examines the procedure-associated costs and operating margins associated with EVAR at a tertiary care academic medical center. All infrarenal EVARs performed from April 2011 to March 2012 were identified (n = 127). Among this cohort, 49 patients met standard commercial instruction for use guidelines, were treated using a single manufacturer device, and billed to Medicare diagnosis-related group (DRG) 238. Of these 49 patients, net technical operating margins (technical revenue minus technical cost) were calculated in conjunction with the hospital finance department. EVAR implant costs were determined for each procedure. DRG 238-associated costs and length of stay were benchmarked against other academic medical centers using University Health System Consortium 2012 data. Among the studied EVAR cohort (age 75, 82% male, mean length of stay, 1.7 days), mean technical costs totaled $31,672. Graft implants accounted for 52% of the allocated technical costs. Institutional overhead was 17% ($5495) of total technical costs. Net mean total technical EVAR-associated operating margins were -$4015 per procedure. Our institutional costs and length of stay, when benchmarked against comparable centers, remained in the lowest quartile nationally using University Health System Consortium costs for DRG 238. Stent graft price did not correlate with total EVAR market share. EVAR is currently associated with significant negative operating margins among Medicare beneficiaries. Currently, device costs account for over 50% of EVAR-associated technical costs and did not impact EVAR market share, reflecting an unawareness of cost differential among surgeons. These data indicate that EVAR must undergo dramatic care delivery redesign for this practice to remain sustainable. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  20. Colorectal endoscopic submucosal dissection: Recent technical advances for safe and successful procedures

    PubMed Central

    Yamamoto, Katsumi; Michida, Tomoki; Nishida, Tsutomu; Hayashi, Shiro; Naito, Masafumi; Ito, Toshifumi

    2015-01-01

    Endoscopic submucosal dissection (ESD) is very useful in en bloc resection of large superficial colorectal tumors but is a technically difficult procedure because the colonic wall is thin and endoscopic maneuverability is poor because of colonic flexure and extensibility. A high risk of perforation has been reported in colorectal ESD. To prevent complications such as perforation and unexpected bleeding, it is crucial to ensure good visualization of the submucosal layer by creating a mucosal flap, which is an exfoliated mucosa for inserting the tip of the endoscope under it. The creation of a mucosal flap is often technically difficult; however, various types of equipment, appropriate strategy, and novel procedures including our clip-flap method, appear to facilitate mucosal flap creation, improving the safety and success rate of ESD. Favorable treatment outcomes with colorectal ESD have already been reported in many advanced institutions, and appropriate understanding of techniques and development of training systems are required for world-wide standardization of colorectal ESD. Here, we describe recent technical advances for safe and successful colorectal ESD. PMID:26468335

  1. Transfer of knowledge in international cooperation: the Farmanguinhos - SMM case.

    PubMed

    Silva, Samuel Araujo Gomes da; Duarte, Roberto Gonzalez; Castro, José Márcio de

    2017-01-01

    To analyze the influence of four mechanisms of knowledge transfer (training, technical visits, expatriation, and standard operating procedures) on the different dimensions (potential and realized) of absorptive capacity in international technical cooperation. We examine the case of implementation of the Sociedade Moçambicana de Medicamentos. Data have been collected using semi-structured interviews (applied to 21 professionals of the Sociedade Moçambicana de Medicamentos, Farmanguinhos, FIOCRUZ, and Itamaraty) and official documents. The data of the interviews have been submitted to content analysis, using the software NVivo. Training and technical visits directly influenced the acquisition and, partly, the assimilation of knowledge. Expatriation contributed with the transformation of this knowledge from the development and refinement of operational routines. Finally, the definition of standard operating procedures allowed the Mozambican technicians to be the actors of the transformation of the knowledge previously acquired and assimilated and, at the same time, it laid the foundations for a future exploration of the knowledge. Training and technical visits mainly influence the potential absorptive capacity, while expatriation and standard operating procedures most directly affect the realized absorptive capacity.

  2. OB's high voltage laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1966-01-01

    The January issue of Hi-Tension News provides a detailed description of the advanced surge test facilities and procedures in daily operation at the OB High Voltage Laboratory in Barberton, Ohio. Technical competences achieved in this laboratory contribute to the essential factors of design confirmation to basic studies of ehv insulation systems, conductor and hardware performance, and optimum tower construction. Known throughout the industry for authenticity of its full scale, all weather outdoor testing, OB's High Voltage Laboratory is a full-fledged participant in the NEMA-sponsored program to make testing facilities available on a cooperative basis.

  3. Becoming an expert carer: the process of family carers learning to manage technical health procedures at home.

    PubMed

    McDonald, Janet; McKinlay, Eileen; Keeling, Sally; Levack, William

    2016-09-01

    To describe the learning process of family carers who manage technical health procedures (such as enteral tube feeding, intravenous therapy, dialysis or tracheostomy care) at home. Increasingly, complex procedures are being undertaken at home but little attention has been paid to the experiences of family carers who manage such procedures. Grounded theory, following Charmaz's constructivist approach. Interviews with 26 family carers who managed technical health procedures and 15 health professionals who taught carers such procedures. Data collection took place in New Zealand over 19 months during 2011-2013. Grounded theory procedures of iterative data collection, coding and analysis were followed, with the gradual development of theoretical ideas. The learning journey comprised three phases: (1) an initial, concentrated period of training; (2) novice carers taking responsibility for day-to-day care of procedures while continuing their learning; and (3) with time, experience and ongoing self-directed learning, the development of expertise. Teaching and support by health professionals (predominantly nurses) was focussed on the initial phase, but carers' learning continued throughout, developed through their own experience and using additional sources of information (notably the Internet and other carers). Further work is needed to determine the best educational process for carers, including where to locate training, who should teach them, optimal teaching methods and how structured or individualized teaching should be. Supporting carers well also benefits patient care. © 2016 John Wiley & Sons Ltd.

  4. Transjugular intrahepatic porto-systemic shunt in the elderly: Palliation for complications of portal hypertension.

    PubMed

    Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert

    2012-02-27

    To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients.

  5. STP 4-06 Model-Based Technical Data in Procurement, 3D PDF Technology Data Demonstration Project. Phase 1 Summary

    DTIC Science & Technology

    2015-07-01

    O R G STP 4-06 MODEL-BASED TECHNICAL DATA IN PROCUREMENT 3D PDF TECHNOLOGY DATA DEMONSTRATION PROJECT PHASE 1 SUMMARY REPORT DL309T2...LMI’s ISO- certified quality management procedures. J U L Y 2 0 1 5 STP 4-06 MODEL-BASED TECHNICAL DATA IN PROCUREMENT 3D PDF TECHNICAL DATA...Based Technical Data ..................................................................................... 5 3D PDF Demonstration Team

  6. Factor structure of the Wechsler Intelligence Scale for Children-Fifth Edition: Exploratory factor analyses with the 16 primary and secondary subtests.

    PubMed

    Canivez, Gary L; Watkins, Marley W; Dombrowski, Stefan C

    2016-08-01

    The factor structure of the 16 Primary and Secondary subtests of the Wechsler Intelligence Scale for Children-Fifth Edition (WISC-V; Wechsler, 2014a) standardization sample was examined with exploratory factor analytic methods (EFA) not included in the WISC-V Technical and Interpretive Manual (Wechsler, 2014b). Factor extraction criteria suggested 1 to 4 factors and results favored 4 first-order factors. When this structure was transformed with the Schmid and Leiman (1957) orthogonalization procedure, the hierarchical g-factor accounted for large portions of total and common variance while the 4 first-order factors accounted for small portions of total and common variance; rendering interpretation at the factor index level less appropriate. Although the publisher favored a 5-factor model where the Perceptual Reasoning factor was split into separate Visual Spatial and Fluid Reasoning dimensions, no evidence for 5 factors was found. It was concluded that the WISC-V provides strong measurement of general intelligence and clinical interpretation should be primarily, if not exclusively, at that level. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  7. Information Exchange Procedures. Outcomes Study Procedures. Technical Report No. 66.

    ERIC Educational Resources Information Center

    Byers, Maureen

    The Information Exchange Procedures (IEP) developed by the National Center for Higher Education Management Systems (NCHEMS) are a set of standard definitions and procedures for collecting information about disciplines and student degree programs, outcomes of instructional programs, and general institutional characteristics. A fundamental purpose…

  8. Methylation analysis of polysaccharides: Technical advice.

    PubMed

    Sims, Ian M; Carnachan, Susan M; Bell, Tracey J; Hinkley, Simon F R

    2018-05-15

    Glycosyl linkage (methylation) analysis is used widely for the structural determination of oligo- and poly-saccharides. The procedure involves derivatisation of the individual component sugars of a polysaccharide to partially methylated alditol acetates which are analysed and quantified by gas chromatography-mass spectrometry. The linkage positions for each component sugar can be determined by correctly identifying the partially methylated alditol acetates. Although the methods are well established, there are many technical aspects to this procedure and both careful attention to detail and considerable experience are required to achieve a successful methylation analysis and to correctly interpret the data generated. The aim of this article is to provide the technical details and critical procedural steps necessary for a successful methylation analysis and to assist researchers (a) with interpreting data correctly and (b) in providing the comprehensive data required for reviewers to fully assess the work. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. [High voltage objects and radiocommunication investments in view of requirements of the environmental protection act].

    PubMed

    Szuba, Marek

    2006-01-01

    This paper presents the most important elements of the localization procedure of high voltage overhead lines and substations and radiocommunication objects which are the source of electromagnetic fields. These fields are perceived as a major threat to human health. The point of departure to make a choice of investments is the special classification of technical installations described in one of the executive directive issued by virtue of the Environmental Protection Act. This special executive directive enumerates a lot of technical objects (installation), classified in the group of investments which have significant impact on the environment and some objects which could be classified in this group. For all this technical installations (e.g., overhead high voltage power lines) the provisions of the Environmental Protection Act impose an obligation to take particular steps to assure transparency of the environmental protection procedures, transborder procedures and the protection of areas included in the Natura 2000 network.

  10. Procedures for Determining Historical Full Costs. Technical Report 65. Second Edition.

    ERIC Educational Resources Information Center

    National Association of College and University Business Officers, Washington, DC.

    The procedures form the costing component of the National Center for Higher Education Management Systems'"Information Exchange Procedures" (IEP). The IEP are a set of standard definitions and procedures for collecting information about disciplines and student degree programs, outcomes of instructional programs, and general institutional…

  11. What Consultation and Freelance Writing Can Do for You and for Your Students.

    ERIC Educational Resources Information Center

    Muller, John A.

    This paper advises teachers of technical writing to "practice what they preach" by occasionally doing field work in technical communication. The possibilities for off-campus work include consultation, perhaps for an in-house manual of technical writing procedures and skills, editing assignments for businesses and public agencies, and freelance…

  12. 15 CFR 40.3 - Cooperation with bilateral technical assistance programs of the United States.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Cooperation with bilateral technical... to Commerce and Foreign Trade BUREAU OF THE CENSUS, DEPARTMENT OF COMMERCE TRAINING OF FOREIGN PARTICIPANTS IN CENSUS PROCEDURES AND GENERAL STATISTICS § 40.3 Cooperation with bilateral technical assistance...

  13. Design Study for Project on Standard Operating Procedures for Technical Library Services.

    ERIC Educational Resources Information Center

    Libbey, Miles A.; And Others

    The overall objective of the Technical Information Support Activities (TISA) Project is the production of a "Post Commander's Handbook." The handbook will be instrumental in achieving greater utilization of available technical information resources to assist army scientists and engineers engaged in the support of army combat and other…

  14. RTO Technical Publications: A Quarterly Listing

    NASA Technical Reports Server (NTRS)

    2005-01-01

    A quarterly listing of RTO technical publications is presented. The topics include: Handbook on the Analysis of Smaller-Scale Contingency Operations in Long Term Defence Planning; 2) Radar Polarimetry and Interferometry; 3) Combat Casualty Care in Ground-Based Tactical Situations: Trauma Technology and Emergency Medical Procedures; and 4) RTO Technical Publications: A Quarterly Listing

  15. 76 FR 52955 - Medicare Program; Meeting of the Technical Advisory Panel on Medicare Trustee Reports

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-24

    ... Panel's discussion is expected to be very technical in nature and will focus on the actuarial and... discussion is expected to focus on highly technical aspects of estimation involving economics and actuarial science. Panelists are not restricted, however, in the topics that they choose to discuss. Procedure and...

  16. 76 FR 58514 - Medicare Program; Meeting of the Technical Advisory Panel on Medicare Trustee Reports

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-21

    ... to be very technical in nature and will focus on the actuarial and economic assumptions and methods... discussion is expected to focus on highly technical aspects of estimation involving economics and actuarial science. Panelists are not restricted, however, in the topics that they choose to discuss. Procedure and...

  17. Approval of Modified Seating Systems Initially Approved Under A Technical Standard Order

    DOT National Transportation Integrated Search

    1997-06-03

    The Advisory Circular (AC) provides information, clarification, and procedural : guidance concerning the approval and installation of modified Technical Standard : Order (TSO) seating systems in U.S. type certificated aircraft.

  18. PRODUCTION OF HEAVY WATER SAVANNAH RIVER AND DANA PLANTS. Technical Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bebbington, W.P.; Thayer, V.R. eds.; Proctor, J.F. comp.

    1959-07-01

    A summary is presented of the basic technical iniormation that pertains to processes that are used at the Dana and Savannah River Plants for the production of heavy water. The manual is intended primarily for plant operating and technical personnel and was prepared to supplement and provide technical support for detailed operating procedures. Introductory sections contain some background information on the history, uses, available processes, and analytical procedures for heavy water. They also include a general comparison of the design and laserformance of the two plants and an analysis of their differences. The technology of the heavy water separation processesmore » used, namely hydrogen sulfide exchange, distillation of water, and electrolysis is discussed in detail. The manufacture and storage of hydrogen sulfide gas and the process water treatment facilities are also discussed. (auth)« less

  19. Lightning arrestor connector lead magnesium niobate qualification pellet test procedures.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuohig, W.; Mahoney, Patrick A.; Tuttle, Bruce Andrew

    2009-02-01

    Enhanced knowledge preservation for DOE DP technical component activities has recently received much attention. As part of this recent knowledge preservation effort, improved documentation of the sample preparation and electrical testing procedures for lead magnesium niobate--lead titanate (PMN/PT) qualification pellets was completed. The qualification pellets are fabricated from the same parent powders used to produce PMN/PT lightning arrestor connector (LAC) granules at HWF&T. In our report, the procedures for fired pellet surface preparation, electrode deposition, electrical testing and data recording are described. The dielectric measurements described in our report are an information only test. Technical reasons for selecting the electrodemore » material, electrode size and geometry are presented. The electrical testing is based on measuring the dielectric constant and dissipation factor of the pellet during cooling from 280 C to 220 C. The most important data are the temperature for which the peak dielectric constant occurs (Curie Point temperature) and the peak dielectric constant magnitude. We determined that the peak dielectric constant for our procedure would be that measured at 1 kHz at the Curie Point. Both the peak dielectric constant and the Curie point parameters provide semi-quantitative information concerning the chemical and microstructural homogeneity of the parent material used for the production of PMN/PT granules for LACs. Finally, we have proposed flag limits for the dielectric data for the pellets. Specifically, if the temperature of the peak dielectric constant falls outside the range of 250 C {+-} 30 C we propose that a flag limit be imposed that will initiate communication between production agency and design agency personnel. If the peak dielectric constant measured falls outside the range 25,000 {+-} 10,000 we also propose that a flag limit be imposed.« less

  20. Qualitative and quantitative analysis of women's perceptions of transvaginal surgery.

    PubMed

    Bingener, Juliane; Sloan, Jeff A; Ghosh, Karthik; McConico, Andrea; Mariani, Andrea

    2012-04-01

    Prior surveys evaluating women's perceptions of transvaginal surgery both support and refute the acceptability of transvaginal access. Most surveys employed mainly quantitative analysis, limiting the insight into the women's perspective. In this mixed-methods study, we include qualitative and quantitative methodology to assess women's perceptions of transvaginal procedures. Women seen at the outpatient clinics of a tertiary-care center were asked to complete a survey. Demographics and preferences for appendectomy, cholecystectomy, and tubal ligation were elicited, along with open-ended questions about concerns or benefits of transvaginal access. Multivariate logistic regression models were constructed to examine the impact of age, education, parity, and prior transvaginal procedures on preferences. For the qualitative evaluation, content analysis by independent investigators identified themes, issues, and concerns raised in the comments. The completed survey tool was returned by 409 women (grouped mean age 53 years, mean number of 2 children, 82% ≥ some college education, and 56% with previous transvaginal procedure). The transvaginal approach was acceptable for tubal ligation to 59%, for appendectomy to 43%, and for cholecystectomy to 41% of the women. The most frequently mentioned factors that would make women prefer a vaginal approach were decreased invasiveness (14.4%), recovery time (13.9%), scarring (13.7%), pain (6%), and surgical entry location relative to organ removed (4.4%). The most frequently mentioned concerns about the vaginal approach were the possibility of complications/safety (14.7%), pain (9%), infection (5.6%), and recovery time (4.9%). A number of women voiced technical concerns about the vaginal approach. As in prior studies, scarring and pain were important issues to be considered, but recovery time and increased invasiveness were also in the "top five" list. The surveyed women appeared to actively participate in evaluating the technical components of the procedures.

  1. Escalating role of piezosurgery in dental therapeutics.

    PubMed

    Agarwal, Esha; Masamatti, Sujata Surendra; Kumar, Ashish

    2014-10-01

    Dentistry, an art in science and tranquilizer in medicine, has seen a lot of changing concepts over a decade and one such novel innovation is piezosurgery. Piezosurgery is a true revolution in bone surgery as it fulfils both biological and technical criteria. It has a variety of applications ranging from minor surgical procedures to complex implantology, plastic and reconstructive surgeries. Piezosurgery uses a low frequency modulated ultrasonic insert which produces microvibrations in the range of 60-200micro meter/sec and leads to safe and precise bony incision without damaging underlying vital structures like nerves, mucosa and vessels. It overcomes technical difficulties such as visibility by producing bloodless field during surgery and removes debris simultaneously through internal irrigation mechanism. The soft tissues remain safe and biological factors like release of certain cytokines promote bone healing and enhance patients recovery. This critical review outweighs piezosurgery over traditional tools and emphasizes on its clinical and biological aspects contributing to beneficial dental health.

  2. Virtual Preoperative Planning and Intraoperative Navigation in Facial Prosthetic Reconstruction: A Technical Note.

    PubMed

    Verma, Suzanne; Gonzalez, Marianela; Schow, Sterling R; Triplett, R Gilbert

    This technical protocol outlines the use of computer-assisted image-guided technology for the preoperative planning and intraoperative procedures involved in implant-retained facial prosthetic treatment. A contributing factor for a successful prosthetic restoration is accurate preoperative planning to identify prosthetically driven implant locations that maximize bone contact and enhance cosmetic outcomes. Navigational systems virtually transfer precise digital planning into the operative field for placing implants to support prosthetic restorations. In this protocol, there is no need to construct a physical, and sometimes inaccurate, surgical guide. The report addresses treatment workflow, radiologic data specifications, and special considerations in data acquisition, virtual preoperative planning, and intraoperative navigation for the prosthetic reconstruction of unilateral, bilateral, and midface defects. Utilization of this protocol for the planning and surgical placement of craniofacial bone-anchored implants allows positioning of implants to be prosthetically driven, accurate, precise, and efficient, and leads to a more predictable treatment outcome.

  3. Assessing the surgical skills of trainees in the operating theatre: a prospective observational study of the methodology.

    PubMed

    Beard, J D; Marriott, J; Purdie, H; Crossley, J

    2011-01-01

    To compare user satisfaction and acceptability, reliability and validity of three different methods of assessing the surgical skills of trainees by direct observation in the operating theatre across a range of different surgical specialties and index procedures. A 2-year prospective, observational study in the operating theatres of three teaching hospitals in Sheffield. The assessment methods were procedure-based assessment (PBA), Objective Structured Assessment of Technical Skills (OSATS) and Non-technical Skills for Surgeons (NOTSS). The specialties were obstetrics and gynaecology (O&G) and upper gastrointestinal, colorectal, cardiac, vascular and orthopaedic surgery. Two to four typical index procedures were selected from each specialty. Surgical trainees were directly observed performing typical index procedures and assessed using a combination of two of the three methods (OSATS or PBA and NOTSS for O&G, PBA and NOTSS for the other specialties) by the consultant clinical supervisor for the case and the anaesthetist and/or scrub nurse, as well as one or more independent assessors from the research team. Information on user satisfaction and acceptability of each assessment method from both assessor and trainee perspectives was obtained from structured questionnaires. The reliability of each method was measured using generalisability theory. Aspects of validity included the internal structure of each tool and correlation between tools, construct validity, predictive validity, interprocedural differences, the effect of assessor designation and the effect of assessment on performance. Of the 558 patients who were consented, a total of 437 (78%) cases were included in the study: 51 consultant clinical supervisors, 56 anaesthetists, 39 nurses, 2 surgical care practitioners and 4 independent assessors provided 1635 assessments on 85 trainees undertaking the 437 cases. A total of 749 PBAs, 695 NOTSS and 191 OSATSs were performed. Non-O&G clinical supervisors and trainees provided mixed, but predominantly positive, responses about a range of applications of PBA. Most felt that PBA was important in surgical education, and would use it again in the future and did not feel that it added time to the operating list. The overall satisfaction of O&G clinical supervisors and trainees with OSATS was not as high, and a majority of those who used both preferred PBA. A majority of anaesthetists and nurses felt that NOTSS allowed them to rate interpersonal skills (communication, teamwork and leadership) more easily than cognitive skills (situation awareness and decision-making), that it had formative value and that it was a valuable adjunct to the assessment of technical skills. PBA demonstrated high reliability (G > 0.8 for only three assessor judgements on the same index procedure). OSATS had lower reliability (G > 0.8 for five assessor judgements on the same index procedure). Both were less reliable on a mix of procedures because of strong procedure-specific factors. A direct comparison of PBA between O&G and non-O&G cases showed a striking difference in reliability. Within O&G, a good level of reliability (G > 0.8) could not be obtained using a feasible number of assessments. Conversely, the reliability within non-O&G cases was exceptionally high, with only two assessor judgements being required. The reasons for this difference probably include the more summative purpose of assessment in O&G and the much higher proportion of O&G trainees in this study with training concerns (42% vs 4%). The reliability of NOTSS was lower than that for PBA. Reliability for the same procedure (G > 0.8) required six assessor judgements. However, as procedure-specific factors exerted a lesser influence on NOTSS, reliability on a mix of procedures could be achieved using only eight assessor judgements. NOTSS also demonstrated a valid internal structure. The strongest correlations between NOTSS and PBA or OSATS were in the 'decision-making' domain. PBA and NOTSS showed better construct validity than OSATS, the year of training and the number of recent index procedures performed being significant independent predictors of performance. There was little variation in scoring between different procedures or different designations of assessor. The results suggest that PBA is a reliable and acceptable method of assessing surgical skills, with good construct validity. Specialties that use OSATS may wish to consider changing the design or switching to PBA. Whatever workplace-based assessment method is used, the purpose, timing and frequency of assessment require detailed guidance. NOTSS is a promising tool for the assessment of non-technical skills, and surgical specialties may wish to consider its inclusion in their assessment framework. Further research is required into the use of health-care professionals other than consultant surgeons to assess trainees, the relationship between performance and experience, the educational impact of assessment and the additional value of video recording.

  4. Engineering Technical Review Planning Briefing

    NASA Technical Reports Server (NTRS)

    Gardner, Terrie

    2012-01-01

    The general topics covered in the engineering technical planning briefing are 1) overviews of NASA, Marshall Space Flight Center (MSFC), and Engineering, 2) the NASA Systems Engineering(SE) Engine and its implementation , 3) the NASA Project Life Cycle, 4) MSFC Technical Management Branch Services in relation to the SE Engine and the Project Life Cycle , 5) Technical Reviews, 6) NASA Human Factor Design Guidance , and 7) the MSFC Human Factors Team. The engineering technical review portion of the presentation is the primary focus of the overall presentation and will address the definition of a design review, execution guidance, the essential stages of a technical review, and the overall review planning life cycle. Examples of a technical review plan content, review approaches, review schedules, and the review process will be provided and discussed. The human factors portion of the presentation will focus on the NASA guidance for human factors. Human factors definition, categories, design guidance, and human factor specialist roles will be addressed. In addition, the NASA Systems Engineering Engine description, definition, and application will be reviewed as background leading into the NASA Project Life Cycle Overview and technical review planning discussion.

  5. Development of CMS monitoring procedures : technical summary.

    DOT National Transportation Integrated Search

    1998-04-01

    This research study is concerned with the development of a set of procedures for monitoring congestion using GPS and GIS. These procedures are meant to be used more as a planning tool than for everyday traffic monitoring. Under this assumption, a ser...

  6. A comparative evaluation of two decompression procedures for technical diving using inflammatory responses: compartmental versus ratio deco.

    PubMed

    Spisni, Enzo; Marabotti, Claudio; De Fazio, Luigia; Valerii, Maria Chiara; Cavazza, Elena; Brambilla, Stefano; Hoxha, Klarida; L'Abbate, Antonio; Longobardi, Pasquale

    2017-03-01

    The aim of this study was to compare two decompression procedures commonly adopted by technical divers: the ZH-L16 algorithm modified by 30/85 gradient factors (compartmental decompression model, CDM) versus the 'ratio decompression strategy' (RDS). The comparison was based on an analysis of changes in diver circulating inflammatory profiles caused by decompression from a single dive. Fifty-one technical divers performed a single trimix dive to 50 metres' sea water (msw) for 25 minutes followed by enriched air (EAN50) and oxygen decompression. Twenty-three divers decompressed according to a CDM schedule and 28 divers decompressed according to a RDS schedule. Peripheral blood for detection of inflammatory markers was collected before and 90 min after diving. Venous gas emboli were measured 30 min after diving using 2D echocardiography. Matched groups of 23 recreational divers (dive to 30 msw; 25 min) and 25 swimmers were also enrolled as control groups to assess the effects of decompression from a standard air dive or of exercise alone on the inflammatory profile. Echocardiography at the single 30 min observation post dive showed no significant differences between the two decompression procedures. Divers adopting the RDS showed a worsening of post-dive inflammatory profile compared to the CDM group, with significant increases in circulating chemokines CCL2 (P = 0.001) and CCL5 (P = 0.006) levels. There was no increase in chemokines following the CDM decompression. The air scuba group also showed a statistically significant increase in CCL2 (P < 0.001) and CCL5 (P = 0.003) levels post dive. No cases of decompression sickness occurred. The ratio deco strategy did not confer any benefit in terms of bubbles but showed the disadvantage of increased decompression-associated secretion of inflammatory chemokines involved in the development of vascular damage.

  7. 42 CFR 411.351 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...

  8. 42 CFR 411.351 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...

  9. 42 CFR 411.351 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...

  10. 44 CFR 78.7 - Grant application procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION ASSISTANCE § 78.7 Grant application procedures. States will apply for Technical Assistance and...

  11. 44 CFR 78.7 - Grant application procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION ASSISTANCE § 78.7 Grant application procedures. States will apply for Technical Assistance and...

  12. 44 CFR 78.7 - Grant application procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION ASSISTANCE § 78.7 Grant application procedures. States will apply for Technical Assistance and...

  13. 44 CFR 78.7 - Grant application procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION ASSISTANCE § 78.7 Grant application procedures. States will apply for Technical Assistance and...

  14. 44 CFR 78.7 - Grant application procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION ASSISTANCE § 78.7 Grant application procedures. States will apply for Technical Assistance and...

  15. The Unfortunate Human Factor: A Selective History of Human Factors for Technical Communicators.

    ERIC Educational Resources Information Center

    Johnson, Robert R.

    1994-01-01

    Reviews moments in the history of human factors that are especially relevant to the field of technical communications. Discusses human factors research that is applicable to technical communications. Focuses on qualitative usability research, minimalism, and human activity interface design. (HB)

  16. Synergistic effect of business reputation in the result of application of innovations on the enterprises of the transport industry

    NASA Astrophysics Data System (ADS)

    Doroshin, Ivan; Diakonova, Sophia; Sharapova, Elena

    2017-10-01

    In the conditions of dynamic innovative development of the enterprises of transport branch along with maintaining economic instability it has become necessary to consider not only traditional factors at assessment of efficiency of activity and cost of business, but also consider business reputation factor, which depends on the level of innovative development of the enterprise and generates effect of synergy. Paper considers the concept of synergistic effect. Classification of types of synergistic effects is cited. Estimation procedure for influence of the technical level and innovative development of transport enterprises on the value of business reputation is considered. Functional dependence of the cost of business reputation on the innovative development and synergistic effect is defined.

  17. Planning a DSN support section technical library

    NASA Technical Reports Server (NTRS)

    Bailey, T.; Chatburn, C. C.

    1980-01-01

    The planning procedure being used to establish a technical library for the Deep Space Network support section is described. The inventory and survey methods employed are described and the preliminary results of these methods are discussed.

  18. An Environmental Management Model of Thermal Waters in Entre Ríos Province, Argentina

    NASA Astrophysics Data System (ADS)

    Pablo, Mársico Daniel; Luís, Díaz Eduardo; Ivana, Zecca; Oscar, Dallacosta; Antonio, Paz-González

    2015-04-01

    Deep exploratory drillings, i.e. those with more than 500 meters depth, have been performed in the Entre Ríos province, Argentina, in order to ascertain the presence of thermal water. Drilling began in 1994, and until now there have been 18 polls with very variable results in terms of mineralization, resource flow, and temperature. The aim of this study was to present a management model, which should allow operators of thermal complexes to further develop procedures for safeguarding the biodiversity of the ecosystems involved, both during exploration and exploitation activities. The environmental management Plan proposed is constituted by a set of technical procedures that are formulated and should be performed during the stages of exploration and exploitation of the resource, and consists of: environmental monitoring, environmental audit, public information and contingency programs. This Plan describes the measures and proposals aimed at protecting environmental quality in the area of influence of a thermal complex project, ensuring that its execution remains environmentally responsibly, and allowing implementation of specific actions to prevent or correct environmental impacts, as predicted in the evaluation of the Environmental Program. The audit of environmental impact includes and takes into account natural factors, such as water, soil, atmosphere, flora and fauna, and also cultural factors. The technical audit Plan was prepared in order to get a systematic structure and organization of the verification process, and also with regard to document the degree of implementation of the proposed mitigation measures. Finally, an environmental contingency program was implemented, and its objective was to consider the safeguarding of life and its natural environment. Thus, a guide has been developed with the main actions to be taken on a contingency, since forecast increases the efficiency of the response. The methodology developed here was adopted as the procedure required by the authority for the application and regulation of the hydro-geo-thermal resources of the province of Entre Ríos, and it is also useful for the control and protection of the resource.

  19. Ontogeny of a surgical technique: Robotic kidney transplantation with regional hypothermia.

    PubMed

    Sood, Akshay; McCulloch, Peter; Dahm, Philipp; Ahlawat, Rajesh; Jeong, Wooju; Bhandari, Mahendra; Menon, Mani

    2016-01-01

    Innovation is a hallmark of surgical practice. It is generally accepted that a new procedure will undergo technical changes during its evolution; however, quantitative accounts of the process are limited. Multiple groups, including our own, have recently described a minimally-invasive approach to conventional kidney transplantation (KT) operation. Unique to our experience is a structured development of the technique within the confines of a safe surgical innovation framework - the IDEAL framework (idea, development, exploration, assessment, long-term monitoring; stages 0-4). We here provide a first-hand narrative of the progress of robotic KT operation from preclinical trial to clinical application. Overall, 54 patients underwent robotic KT with regional hypothermia successfully. Major technical changes including selection of optimal patient position (flank vs. lithotomy), robotic instrumentation, vascular occlusion method (bulldog vs. tourniquet) and suture material (prolene vs. GoreTex) occurred early during the procedure development (IDEAL stage 0, preclinical). Minor technical changes such as utilization of the aortic punch for arteriotomy (case 3), use of barbed suture during ureteroneocystostomy (case 6) and extraperitonealization of the graft kidney (case 6) that increased the efficiency and safety of the procedure continued throughout procedure development (IDEAL stages 1-2, clinical stages). We demonstrate that a surgical technique evolves continually; although, the majority of technical alterations occur early in the life-cycle of the procedure. Development of a new technique within the confines a structured surgical innovation framework allows for evidence based progression of the technique and may minimize the risk of harm to the patient. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  20. Vertebral Artery Origin Stent Placement Using the Dual Lumen Qureshi-Jiao Guidecatheter

    PubMed Central

    Qureshi, Adnan I.; Wang, Yabing; Afzal, Mohammad Rauf; Jiao, Liqun

    2017-01-01

    Objective We report the first experience with a new dual lumen guide catheter with lumen A with curved tip designed for delivery of stent and angioplasty catheters and lumen B with side exit for coaxial placement of stiff 0.014 inch wire. Methods We prospectively determined technical success, intended procedure (stent delivery at target lesion and a final residual stenosis <30%) completed without a need for a different catheter, and technical ease, intended procedure completed without ≥3 unsuccessful attempts in patients with symptomatic vertebral artery origin stenosis. Vertebral artery origin was classified as type A if originated from ascending segment and type B if originated from an arch or horizontal segment of subclavian artery. Results The mean age of the four treated patients was 66.2 years (range 64–68 years). The mean percentage of vertebral artery origin stenosis was 82.7% (range 60–92%). The origin of vertebral artery from subclavian artery was classified as type A and type B origins in two patients each. The dual lumen catheter was advanced over an exchange length of 0.035 inch glide wire in one patient and directly through transfemoral insertion in three patients. Technical success and technical ease was achieved in all four procedures. Post procedure residual stenosis was 6% (range 5–7%). The primary operator rated the performance of guide catheter as superior compared with another catheter used in such procedures. Conclusion The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a dual lumen catheter with superior performance. PMID:29445438

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien; Department of Interventional Radiology, Nouvel Hôpital Civil

    ObjectivesThe purpose of this study is to discuss technical aspects and rationales of magnetic resonance (MR)-guided cryoablation (CA) of Morton’s neuroma (MN); preliminary clinical experience is also retrospectively reviewed.MethodsProcedures were performed under local anaesthesia on an outpatient basis. Lesion size and location, procedural (technical success, procedural time, complications) and clinical outcomes (patient satisfaction according to a four-point scale, residual pain according to a 0–10 visual analogue scale and instances of “stump neuroma”) were assessed via chart review and cross-sectional telephone survey after the 20th case.ResultsTwenty patients (15 female, 5 male; mean age 50.3 years) were included; 24 MN (mean size 12.7 mm)more » were treated. Technical success was 100 %. Mean procedural time was 40.9 ± 10.4 min (range 35–60). One minor complication (superficial cellulitis) was reported (4.2 %). Follow-up (mean 19.7 months) was available for 18/24 MN. Patient satisfaction on a per-lesion basis was as follows: “completely satisfied” in 77.7 %, “satisfied with minor reservations” in 16.6 % and “satisfied with major reservations” in 5.7 % of cases. Mean pain score at last follow-up post-CA was 3.0. No instances of “stump neuroma” were reported.ConclusionsMR-guided CA of MN is a novel therapy which appears technically feasible. Clinical advantages of the procedure are high patient satisfaction, reduced risk of “stump neuroma” syndrome and good patient tolerance on an outpatient basis. Further, prospective studies are needed to confirm these encouraging results.« less

  2. Patient-specific simulation in carotid artery stenting.

    PubMed

    Willaert, Willem; Aggarwal, Rajesh; Bicknell, Colin; Hamady, Mo; Darzi, Ara; Vermassen, Frank; Cheshire, Nicholas

    2010-12-01

    Patient-specific virtual reality (VR) simulation is a technologic advancement that allows planning and practice of the carotid artery stenting (CAS) procedure before it is performed on the patient. The initial findings are reported, using this novel VR technique as a tool to optimize technical and nontechnical aspects of this complex endovascular procedure. In the angiography suite, the same interventional team performed the VR rehearsal and the actual CAS on the patient. All proceedings were recorded to allow for video analysis of team, technical, and nontechnical skills. Analysis of both procedures showed identical use of endovascular tools, similar access strategy, and a high degree of similarity between the angiography images. The total procedure time (24.04 vs 60.44 minutes), fluoroscopy time (11.19 vs 21.04 minutes), and cannulation of the common carotid artery (1.35 vs 9.34) took considerably longer in reality. An extensive questionnaire revealed that all team members found that the rehearsal increased the subjective sense of teamwork (4/5), communication (4/5), and patient safety (4/5). A VR procedure rehearsal is a practical and feasible preparatory tool for CAS and shows a high correlation with the real procedure. It has the potential to enhance the technical, nontechnical, and team performance. Further research is needed to evaluate if this technology can lead to improved outcomes for patients. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  3. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...

  4. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...

  5. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...

  6. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...

  7. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...

  8. Transjugular intrahepatic porto-systemic shunt in the elderly: Palliation for complications of portal hypertension

    PubMed Central

    Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert

    2012-01-01

    AIM: To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. METHODS: A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). RESULTS: Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. CONCLUSION: We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients. PMID:22400084

  9. Development of an improved overlay procedure for Oregon : volume III, field manual.

    DOT National Transportation Integrated Search

    1987-12-01

    This report is the third in a three-volume series dealing with the development of an improved overlay design procedure for Oregon. This report presents technical guidelines for using the proposed overlay design procedure. Four areas are described, in...

  10. NAEP 1999 Long-Term Trend Technical Analysis Report: Three Decades of Student Performance. NCES 2005-484

    ERIC Educational Resources Information Center

    Allen, Nancy L.; McClellan, Catherine A.; Stoeckel, Joan J.

    2005-01-01

    This report provides an update to the technical analysis procedures documenting the 1996 National Assessment of Educational Progress (NAEP) as presented in "The NAEP 1996 Technical Report" (Allen, Carlson, and Zelenak, 1999). It describes how the 1999 long-term trend data were incorporated into the trend analyses. Since no national main…

  11. 76 FR 11417 - Public Workshop and Hearing for Rear Visibility; Federal Motor Vehicle Safety Standard, Rearview...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-02

    ...), Department of Transportation (DOT). ACTION: Notice of proposed rulemaking: Announcement of a public technical... this proposal. The first event, a public technical workshop, will be held on March 11, 2011, to discuss technical issues relevant to the test procedure described in the proposed rule. The second event, a public...

  12. Preparing Research and Development Proposals for Vocational-Technical Education. Research Series No. 40.

    ERIC Educational Resources Information Center

    Lamberth, Edwin E.

    The purpose of this handbook is to present in a simple form the processes and procedures involved in preparing research and development projects in vocational-technical education in the State of Tennessee. It was prepared in conjunction with the Research Coordinating Unit (RCU) and the division of Vocational-Technical Education, State Department…

  13. Observation of behavioural markers of non-technical skills in the operating room and their relationship to intra-operative incidents.

    PubMed

    Siu, Joey; Maran, Nikki; Paterson-Brown, Simon

    2016-06-01

    The importance of non-technical skills in improving surgical safety and performance is now well recognised. Better understanding is needed of the impact that non-technical skills of the multi-disciplinary theatre team have on intra-operative incidents in the operating room (OR) using structured theatre-based assessment. The interaction of non-technical skills that influence surgical safety of the OR team will be explored and made more transparent. Between May-August 2013, a range of procedures in general and vascular surgery in the Royal Infirmary of Edinburgh were performed. Non-technical skills behavioural markers and associated intra-operative incidents were recorded using established behavioural marking systems (NOTSS, ANTS and SPLINTS). Adherence to the surgical safety checklist was also observed. A total of 51 procedures were observed, with 90 recorded incidents - 57 of which were considered avoidable. Poor situational awareness was a common area for surgeons and anaesthetists leading to most intra-operative incidents. Poor communication and teamwork across the whole OR team had a generally large impact on intra-operative incidents. Leadership was shown to be an essential set of skills for the surgeons as demonstrated by the high correlation of poor leadership with intra-operative incidents. Team-working and management skills appeared to be especially important for anaesthetists in the recovery from an intra-operative incident. A significant number of avoidable incidents occur during operative procedures. These can all be linked to failures in non-technical skills. Better training of both individual and team in non-technical skills is needed in order to improve patient safety in the operating room. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  14. Research on the industry environmental total factor productivity in Jiangsu Province based on the SBM-SML

    NASA Astrophysics Data System (ADS)

    Lingfang, Sun; Han, Wang; Jian, Gong

    2017-03-01

    This paper uses the SBM-SML to measure the industry environmental total factor productivity in Jiangsu province of its 13 cities during 2005-2014 with SO2 emissions as the undesirable output, and discomposes the total factor productivity into the pure technical efficiency, the scale efficiency change, the pure technical change and the scale technical change. The research shows that the overall trend of the industry environmental total factor productivity is increasing in Jiangsu province during 2005-2014, the technical change is a main reason pushing up growth rates of economy, and the pure technical change is the intrinsic motivation of the technical change.Introduction.

  15. [Home hemodialysis: the technical overview. A 2010 survey].

    PubMed

    Ponson, Laurent; Arkouche, Walid; Laville, Maurice

    2012-04-01

    Compared to the daily work in dialysis units, home haemodialysis represents a particular task for the technical services of healthcare facilities. This survey concerns this modality of treatment of end-stage chronic renal failure, and was led to three objectives: to make a snapshot of the practices done by the technical staff, to point out significant differences, and to identify common issues. This is also an opportunity to discuss about the future of this treatment. Numbers of registries show a continuous decline of home haemodialysis during past decades. This could be explained by many factors, but on the other hand several points tend to forecast a renewed interest for this method of treatment. A questionnaire was sent to every technical service of health organizations dispensing dialysis in France. Seventeen health facilities providing home haemodialysis have sent back their information, representing 238 patients, that to say almost the totality of the patients of the country. These data were analysed, relevant indicators were sorted out, so that initial objectives could be completed. The results are explained as follows: site activities, procedures before and during patient installation, equipment, preventive visits, and corrective maintenance. In lack of a precise regulation on the technical support of these patients, significant differences of operations were noted and are detailed, as well as several common difficulties. All these elements can be used as a basis for the development of a practical guide intended to technical services. This work is voluntarily centered on the technical aspects, but other levers exist to revitalize this method. Copyright © 2012 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  16. Soil Gas Sampling

    EPA Pesticide Factsheets

    Field Branches Quality System and Technical Procedures: This document describes general and specific procedures, methods and considerations to be used and observed when collecting soil gas samples for field screening or laboratory analysis.

  17. Evaluation of human exposure to complex waveform magnetic fields generated by arc-welding equipment according to European safety standards.

    PubMed

    Zoppetti, Nicola; Bogi, Andrea; Pinto, Iole; Andreuccetti, Daniele

    2015-02-01

    In this paper, a procedure is described for the assessment of human exposure to magnetic fields with complex waveforms generated by arc-welding equipment. The work moves from the analysis of relevant guidelines and technical standards, underlining their strengths and their limits. Then, the procedure is described with particular attention to the techniques used to treat complex waveform fields. Finally, the procedure is applied to concrete cases encountered in the workplace. The discussion of the results highlights the critical points in the procedure, as well as those related to the evolution of the technical and exposure standards. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. [The LESS (Laparo-endoscopic Single-Site) procedure in urology. Technical and clinical aspects].

    PubMed

    Neri, F; Cindolo, L; Gidaro, S; Schips, L

    2010-01-01

    Minimally invasive urology is rapidly advancing, and single-site laparoscopic surgery is being explored clinically. Such laparoscopic procedures are technically challenging and require an experienced laparoscopic surgeon due to the lack of port placement triangulation and instrument clashing. In the last years several surgeons all over the world have explored the feasibility and safety of LESS using several and different ports, approaches and devices. Hundreds of procedures have been described with overall favorable intraoperative and postoperative outcomes. Our experience consists of more than 30 procedures successfully completed for adrenal, kidney disease and varicocele. To date, LESS could be considered feasible and effective using currently available devices, however it is to be considered as an initial status technique requiring further confirmatory studies and advanced laparoscopic skills.

  19. The Role of Physicists in Anti-Terrorism: Transportation

    NASA Astrophysics Data System (ADS)

    Fainberg, Anthony

    2002-04-01

    Physicists, along with many other categories of scientists, participate in efforts against terrorism in a multitude of ways, including developing explosive detectors, sensors, security procedures, technical analyses, and decision tools. Transportation, especially civil aviation, is a field of focus within the anti- and counterterrorism arenas. The most spectacular terrorist acts have generally aimed at this sector and this trend is likely to continue. Physicists play their roles in all sectors: government, private industry, and even academia. Defense against terrorism has become a national priority in the United States, and one may expect the roles of scientific experts to become more important. The tactics of terrorists will change and develop, so it will become necessary to develop ever more sophisticated measures to fight them. Technology is part of the answer, but human factors, vulnerability analyses, threat assessment, and security procedures are equally important.

  20. Transfer of knowledge in international cooperation: the Farmanguinhos – SMM case

    PubMed Central

    da Silva, Samuel Araujo Gomes; Duarte, Roberto Gonzalez; de Castro, José Márcio

    2017-01-01

    ABSTRACT OBJECTIVE To analyze the influence of four mechanisms of knowledge transfer (training, technical visits, expatriation, and standard operating procedures) on the different dimensions (potential and realized) of absorptive capacity in international technical cooperation. METHODS We examine the case of implementation of the Sociedade Moçambicana de Medicamentos. Data have been collected using semi-structured interviews (applied to 21 professionals of the Sociedade Moçambicana de Medicamentos, Farmanguinhos, FIOCRUZ, and Itamaraty) and official documents. The data of the interviews have been submitted to content analysis, using the software NVivo. RESULTS Training and technical visits directly influenced the acquisition and, partly, the assimilation of knowledge. Expatriation contributed with the transformation of this knowledge from the development and refinement of operational routines. Finally, the definition of standard operating procedures allowed the Mozambican technicians to be the actors of the transformation of the knowledge previously acquired and assimilated and, at the same time, it laid the foundations for a future exploration of the knowledge. CONCLUSIONS Training and technical visits mainly influence the potential absorptive capacity, while expatriation and standard operating procedures most directly affect the realized absorptive capacity. PMID:29166441

  1. Transradial access for visceral endovascular interventions in morbidly obese patients: safety and feasibility.

    PubMed

    Biederman, Derek M; Marinelli, Brett; O'Connor, Paul J; Titano, Joseph J; Patel, Rahul S; Kim, Edward; Tabori, Nora E; Nowakowski, Francis S; Lookstein, Robert A; Fischman, Aaron M

    2016-05-07

    Transradial access (TRA) has been shown to lower morbidity and bleeding complications compared to transfemoral access in percutaneous coronary interventions. Morbid obesity, commonly defined as a body mass index (BMI) ≥40 kg/m2, has been shown to be a risk factor for access site complications irrespective of access site. This study evaluates the safety and feasibility of performing visceral endovascular interventions in morbidly obese patients via TRA. Procedural details, technical success, and 30-day major and minor access site, bleeding, and neurological adverse events were prospectively recorded in a database of 1057 procedures performed via the radial artery. From this database we identified 22 visceral interventions performed with TRA in 17 morbidly obese patients (age: 53 ± 11 years, female: 71%) with a median BMI of 42.7 kg/m2. Interventions included radio-embolization (n = 7, 31.8%), chemo-embolization (n = 6, 27.3%), uterine fibroid embolization (n = 4, 18.2%), renal embolization (n = 2, 9.1%), hepatic embolization (n = 1, 4.5%), lumbar artery embolization (n = 1, 4.5%), and renal angioplasty (n = 1, 4.5%). The technical success was 100%. There were no major or minor adverse access site, bleeding, or neurological complications at 30 days. This study suggests visceral endovascular interventions performed in morbidly obese patients are safe and feasible.

  2. 10 CFR 600.144 - Procurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... integrity, record of past performance, financial and technical resources or accessibility to other necessary... DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL ASSISTANCE RULES Uniform Administrative... practicable, of technical requirements in terms of functions to be performed or performance required...

  3. Electrical and optical evaluation aspects of public lighting systems

    NASA Astrophysics Data System (ADS)

    Tulbure, Adrian; Marc, Gheorghe; Kurt, Ünal

    2016-12-01

    This paper briefs a few issues regarding the technical validation of public lighting solutions. The novelty of the work is justified by the fact that it combines technical legislation in force [1], with practical analysis procedures [2]. Thus, in order to select the optimal solution, the paper describes a case study of measurement procedure which confirms the high electrical and optical characteristics [3] of the proposed solutions. At the end of the contribution, comparative design purposes for the two versions of modern street lighting are presented.

  4. 10 CFR 455.62 - Contents of a technical assistance program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... and document energy conservation maintenance and operating procedure changes and energy conservation... operating procedure changes, if any, and energy conservation measures selected in accordance with the State... conservation maintenance and operating procedure change and an estimate of the costs of adopting such energy...

  5. 10 CFR 455.62 - Contents of a technical assistance program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... and document energy conservation maintenance and operating procedure changes and energy conservation... operating procedure changes, if any, and energy conservation measures selected in accordance with the State... conservation maintenance and operating procedure change and an estimate of the costs of adopting such energy...

  6. 10 CFR 455.62 - Contents of a technical assistance program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... and document energy conservation maintenance and operating procedure changes and energy conservation... operating procedure changes, if any, and energy conservation measures selected in accordance with the State... conservation maintenance and operating procedure change and an estimate of the costs of adopting such energy...

  7. 10 CFR 455.62 - Contents of a technical assistance program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... and document energy conservation maintenance and operating procedure changes and energy conservation... operating procedure changes, if any, and energy conservation measures selected in accordance with the State... conservation maintenance and operating procedure change and an estimate of the costs of adopting such energy...

  8. 10 CFR 455.62 - Contents of a technical assistance program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... and document energy conservation maintenance and operating procedure changes and energy conservation... operating procedure changes, if any, and energy conservation measures selected in accordance with the State... conservation maintenance and operating procedure change and an estimate of the costs of adopting such energy...

  9. Designing Flightdeck Procedures: Literature Resources

    NASA Technical Reports Server (NTRS)

    Feldman, Jolene; Barshi, Immanuel; Degani, Asaf; Loukopoulou, Loukia; Mauro, Robert

    2017-01-01

    This technical publication contains the titles, abstracts, summaries, descriptions, and/or annotations of available literature sources on procedure design and development, requirements, and guidance. It is designed to provide users with an easy access to available resources on the topic of procedure design, and with a sense of the contents of these sources. This repository of information is organized into the following publication sources: Research (e.g., journal articles, conference proceedings), Manufacturers' (e.g., operation manuals, newsletters), and Regulatory and/or Government (e.g., advisory circulars, reports). An additional section contains synopses of Accident/Incident Reports involving procedures. This work directly supports a comprehensive memorandum by Barshi, Mauro, Degani, & Loukopoulou (2016) that summarizes the results of a multi-year project, partially funded by the FAA, to develop technical reference materials that support guidance on the process of developing cockpit procedures (see "Designing Flightdeck Procedures" https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20160013263.pdf). An extensive treatment of this topic is presented in a forthcoming book by the same authors.

  10. The Fibroid Registry for outcomes data (FIBROID) for uterine embolization: short-term outcomes.

    PubMed

    Worthington-Kirsch, Robert; Spies, James B; Myers, Evan R; Mulgund, Jyotsna; Mauro, Matthew; Pron, Gaylene; Peterson, Eric D; Goodwin, Scott

    2005-07-01

    To investigate the short-term safety of uterine embolization for leiomyomata in a large cohort of patients treated in a variety of clinical settings. Examining the FIBROID Registry, a multicenter prospective voluntary registry of patients undergoing uterine embolization for leiomyomata, we studied the frequency of adverse events and predictors of adverse events within 30 days of the procedure. We also report on the technical aspects of the procedure, including details of periprocedural care, technique, and short-term recovery. All adverse events were recorded and classified using standard definitions, both in terms of type and severity. Summary statistics were used to describe the data set, and univariate and multivariate analyses were used to determine which factors might influence the incidence of adverse events. Of the 3,160 patients enrolled at 72 contributing sites, major in-hospital complications occurred in 0.66%, and postdischarge major events occurred in 4.8% within the first 30 days. The most common adverse event after discharge was inadequate pain relief requiring additional hospital treatment (2.4%). Thirty-one patients required additional surgical intervention within 30 days after treatment, 3 of whom required hysterectomy (0.1%). There were no deaths. Multivariate analysis showed modest increased odds for an adverse event for African Americans, smokers, and those with prior leiomyoma procedures. There were no differences in outcome based on the practice site experience, practice type, or any procedure-related factors. Uterine embolization for leiomyomata is a low-risk procedure with little variability in short-term outcome based on either patient demographics or practice setting. II-3.

  11. Plug-Assisted Retrograde Transvenous Obliteration for the Treatment of Gastric Varices: The Role of Intra-Procedural Cone-Beam Computed Tomography

    PubMed Central

    Ko, Gi-Young; Kwon, Young Baek; Yoon, Hyun-Ki; Sung, Kyu-Bo

    2018-01-01

    Objective To investigate the technical and clinical outcomes of plug-assisted retrograde transvenous obliteration (PARTO) for the treatment of gastric varices (GV) and to evaluate the role of intra-procedural cone-beam computed tomography (CBCT) performed during PARTO to confirm its technical success. Materials and Methods From January 2016 to December 2016, 17 patients with GV who had undergone PARTO were retrospectively evaluated. When the proximal part of the afferent vein was identified on a fluoroscopy, non-contrast CBCT images were obtained. In patients with incomplete embolization of GV, an additional injection of gelatin sponges was performed. Follow-up data from contrast-enhanced CT and upper intestinal endoscopy, as well as clinical and laboratory data were collected. Results Plug-assisted retrograde transvenous obliteration procedures were technically successful in all 17 patients. Complete embolization of GV was detected on CBCT images in 15 patients; whereas, incomplete embolization was detected in two. Complete embolization of GV was then achieved after an additional injection of gelatin sponges in these two patients as demonstrated on the 2nd CBCT image. The mean follow-up period after PARTO was 193 days (range, 73–383 days). A follow-up CT obtained 2–4 months after PARTO demonstrated marked shrinkage or complete obliteration of GV and portosystemic shunts in all 17 patients. There were no cases of variceal bleeding during the follow-up. Conclusion Plug-assisted retrograde transvenous obliteration is technically and clinically effective for the treatment of GV. In addition, intra-procedural CBCT can be an adjunct tool to fluoroscopy, because it can provide an immediate and accurate evaluation of the technical success of PARTO. PMID:29520179

  12. Surgical resident technical skill self-evaluation: increased precision with training progression.

    PubMed

    Quick, Jacob A; Kudav, Vishal; Doty, Jennifer; Crane, Megan; Bukoski, Alex D; Bennett, Bethany J; Barnes, Stephen L

    2017-10-01

    Surgical resident ability to accurately evaluate one's own skill level is an important part of educational growth. We aimed to determine if differences exist between self and observer technical skill evaluation of surgical residents performing a single procedure. We prospectively enrolled 14 categorical general surgery residents (six post-graduate year [PGY] 1-2, three PGY 3, and five PGY 4-5). Over a 6-month period, following each laparoscopic cholecystectomy, residents and seven faculty each completed the Objective Structured Assessment of Technical Skills (OSATS). Spearman's coefficient was calculated for three groups: senior (PGY 4-5), PGY3, and junior (PGY 1-2). Rho (ρ) values greater than 0.8 were considered well correlated. Of the 125 paired assessments (resident-faculty each evaluating the same case), 58 were completed for senior residents, 54 for PGY3 residents, and 13 for junior residents. Using the mean from all OSATS categories, trainee self-evaluations correlated well to faculty (senior ρ 0.97, PGY3 ρ 0.9, junior ρ 0.9). When specific OSATS categories were analyzed, junior residents exhibited poor correlation in categories of respect for tissue (ρ -0.5), instrument handling (ρ 0.71), operative flow (ρ 0.41), use of assistants (ρ 0.05), procedural knowledge (ρ 0.32), and overall comfort with the procedure (ρ 0.73). PGY3 residents lacked correlation in two OSATS categories, operative flow (ρ 0.7) and procedural knowledge (ρ 0.2). Senior resident self-evaluations exhibited strong correlations to observers in all areas. Surgical residents improve technical skill self-awareness with progressive training. Less-experienced trainees have a tendency to over-or-underestimate technical skill. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Technical and Clinical Outcomes Following Colonic Stenting: A Seven-Year Analysis of 268 Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, M. W.; Oakley, T.; Briggs, J. H.

    AimsTo assess the factors contributing to the technical and clinical success of colorectal stenting for large bowel obstruction.Methodology268 cases of colonic stenting for large bowel obstruction were performed in 249 patients of mean age of 72 years (28–98) between 2006 and 2013. The majority of strictures were due to malignant disease, 244/268 (91 %). Diverticular strictures accounted for 24/268 (9 %).ResultsOverall technical success rate was 81 % (217/268), with a clinical success rate of 65 % (174/268). Duration of symptoms ranged from 0 to 180 days (mean 8 days). Technical success rate was seen to decrease with increasing symptom duration. For symptom duration of less than 1 week,more » technical success was 85.4 % (181/212) versus 69.6 % (39/56) for those with symptoms of greater than a week (p < 0.05). Clinical success rates fell from 71.3 % (107/150) to 59.3 % (70/118) (p < 0.05) when attempting to stent lesions of greater than 5 cm. There was also a significant reduction in clinical success when stenting lesions on a bend rather than a straight segment of colon 75.7 % (109/144) versus 59.7 % (74/124) (p < 0.05). A total of 20 (7.46 %) perforations were identified during the study. Stent migration occurred in 6.6 % of cases. In-stent stenosis occurred in 3.3 %. The overall 30-day all cause mortality rate was 9 %.ConclusionLesion size, location and duration of obstructive symptoms are statistically significant determinants of patient outcome. These factors could be used to advise patient selection for colonic stenting or direct progression to surgical intervention.« less

  14. Management of large bowel obstruction with self-expanding metal stents. A multicentre retrospective study of factors determining outcome.

    PubMed

    Geraghty, J; Sarkar, S; Cox, T; Lal, S; Willert, R; Ramesh, J; Bodger, K; Carlson, G L

    2014-06-01

    UK cancer guidelines recommend patients with colonic obstruction due to suspected malignancy be considered for stenting with a self-expanding metal stent (SEMS). Considerable variation in practice exists due to a lack of expertise, technical difficulties and other, as yet ill-defined features. This retrospective multi-centre study aims to determine the outcome following colonic stenting for large bowel obstruction and identify factors associated with successful intervention. A regional programme of colonic stenting for large bowel obstruction, in five UK centres from 2005 to 2010 was evaluated for outcome including technical and clinical success, survival, complications and reoperation. A SEMS was inserted in 334 patients, including 264 (79.0%) for palliation and 52 (15.6%) as a bridge to surgery. Technical success was achieved in 292 (87.4%) patients, with 46 (13.8%) experiencing a complication or technical failure. Reoperation was required in 39 (14.8%) patients stented for palliation of colorectal cancer of whom 16 (6.1%) subsequently required a colostomy. A one-stage primary anastomosis was achieved in 35 (67.3%) of the 52 patients undergoing stenting as a bridge to resection. Technical success did not vary by indication or site of obstruction (P = 0.60) but was higher for operators who had performed more than 10 procedures (OR 3.34, P = 0.001). ASA grade ≥3 predicted a worse clinical outcome (OR 0.43, P = 0.04). The through-the-scope (TTS) endoscopy technique was more successful than radiological placement alone (90.3% vs 74.8%, P < 0.001). Experienced operators using a TTS technique achieved a better outcome for the emergency management of large bowel obstruction. Older, sicker patients and those with extracolonic and benign strictures fared less well. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  15. Factors predictive of survival after stapler hepatectomy of hepatocellular carcinoma: a multivariate, single-center analysis.

    PubMed

    Hoffmann, Katrin; Müller-Bütow, Verena; Franz, Clemens; Hinz, Ulf; Longerich, Thomas; Büchler, Markus W; Schemmer, Peter

    2014-02-01

    New technical devices for hepatic parenchymal transection have improved perioperative safety and patient survival. The aim of the present study was to determine the oncological outcome after stapler hepatectomy in patients with HCC. Data of 95 patients who underwent stapler hepatectomy for HCC between 2001 and 2011 were analyzed retrospectively regarding clinical safety of the procedure and predictive factors for survial. Thirty-nine minor (≤2 segments) and 56 major (≥3 segments) hepatic resections were performed. The median survival was 47.5 months, after 36 months follow-up. Low grading, tumors ≥5 cm, multiple nodules and liver cirrhosis were predictors of decreased overall survival using multivariate analysis with hazard ratio(HR)=2.62, 2.41, 2.05, and 1.92 respectively. An estimated intra-operative blood loss of ≥1.2l was inversely correlated to disease free survival (HR=1.96). Stapler hepatectomy is a safe procedure in patients with HCC. Substantial intraoperative blood loss and the presence of cirrhosis independently predict the overall probability of patient survival. Intraoperative blood loss directly impacts HCC recurrence.

  16. Intra-operative disruptions, surgeon's mental workload, and technical performance in a full-scale simulated procedure.

    PubMed

    Weigl, Matthias; Stefan, Philipp; Abhari, Kamyar; Wucherer, Patrick; Fallavollita, Pascal; Lazarovici, Marc; Weidert, Simon; Euler, Ekkehard; Catchpole, Ken

    2016-02-01

    Surgical flow disruptions occur frequently and jeopardize perioperative care and surgical performance. So far, insights into subjective and cognitive implications of intra-operative disruptions for surgeons and inherent consequences for performance are inconsistent. This study aimed to investigate the effect of surgical flow disruption on surgeon's intra-operative workload and technical performance. In a full-scale OR simulation, 19 surgeons were randomly allocated to either of the two disruption scenarios (telephone call vs. patient discomfort). Using a mixed virtual reality simulator with a computerized, high-fidelity mannequin, all surgeons were trained in performing a vertebroplasty procedure and subsequently performed such a procedure under experimental conditions. Standardized measures on subjective workload and technical performance (trocar positioning deviation from expert-defined standard, number, and duration of X-ray acquisitions) were collected. Intra-operative workload during simulated disruption scenarios was significantly higher compared to training sessions (p < .01). Surgeons in the telephone call scenario experienced significantly more distraction compared to their colleagues in the patient discomfort scenario (p < .05). However, workload tended to be increased in surgeons who coped with distractions due to patient discomfort. Technical performance was not significantly different between both disruption scenarios. We found a significant association between surgeons' intra-operative workload and technical performance such that surgeons with increased mental workload tended to perform worse (β = .55, p = .04). Surgical flow disruptions affect surgeons' intra-operative workload. Increased mental workload was associated with inferior technical performance. Our simulation-based findings emphasize the need to establish smooth surgical flow which is characterized by a low level of process deviations and disruptions.

  17. 14 CFR 1240.109 - Hearing procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Awards for Scientific and Technical Contributions § 1240.109 Hearing procedure. (a) An Oral hearing held... and arguments in support of the application. Evidence may be presented through means of such witnesses...

  18. 14 CFR 1240.109 - Hearing procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Awards for Scientific and Technical Contributions § 1240.109 Hearing procedure. (a) An Oral hearing held... and arguments in support of the application. Evidence may be presented through means of such witnesses...

  19. 14 CFR 1240.109 - Hearing procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Awards for Scientific and Technical Contributions § 1240.109 Hearing procedure. (a) An Oral hearing held... and arguments in support of the application. Evidence may be presented through means of such witnesses...

  20. The French Space Operation Act: Technical Regulations

    NASA Astrophysics Data System (ADS)

    Trinchero, J. P.; Lazare, B.

    2010-09-01

    The French Space Operation Act(FSOA) stipulates that a prime objective of the National technical regulations is to protect people, property, public health and the environment. Compliance with these technical regulations is mandatory as of 10 December 2010 for space operations by French space operators and for space operations from French territory. The space safety requirements and regulations governing procedures are based on national and international best practices and experience. A critical design review of the space system and procedures shall be carried out by the applicant, in order to verify compliance with the Technical Regulations. An independent technical assessment of the operation is delegated to CNES. The principles applied when drafting technical regulations are as follows: requirements must as far as possible establish the rules according to the objective to be obtained, rather than how it is to be achieved; requirements must give preference to international standards recognised as being the state of the art; requirements must take previous experience into account. Technical regulations are divided into three sections covering common requirements for the launch, control and return of a space object. A dedicated section will cover specific rules to be applied at the Guiana Space Centre. The main topics addressed by the technical regulations are: operator safety management system; study of risks to people, property, public health and the Earth’s environment; impact study on the outer space environment: space debris generated by the operation; planetary protection.

  1. Technical skills rotation for general surgery residents.

    PubMed

    Gonzalez, Ray I; Martinez, Jose M; Iglesias, Alberto R; Lo Menzo, Emanuele; Hutson, Duane; Sleeman, Danny; Livingstone, Alan S; Madan, Atul K

    2010-06-15

    Technical skills are an important part of any general surgery residency curriculum. With the demands of limited work weeks, it is imperative that educators create novel methods of teaching technical skills to their residents. Our program utilizes a dedicated month to help accomplish this. This study hypothesized that general surgery residents would report a positive effect of a dedicated technical skills rotation. Residents who had undergone a 1 mo rotation in technical skills during their first year were asked to fill out a survey concerning their experience. During the 1-mo rotation, the residents had almost no clinical responsibilities. Teaching of technical skills was performed with various activities, including video content (VC), virtual reality simulators (VR), open foam procedures (OF), laparoscopic box trainers (BT), surgical equipment in-service (SE), and animate sessions (AS). Responses were given on a Likert scale (1-10) with higher numbers being more positive responses. There were seven residents in this study. The residents gave a very positive response to the overall rotation (9.4) and exposure to laparoscopic procedures (9.6). The other responses were enthusiastic as well: exposure to open procedures (8.9) and preparation for operative room (9.4). After their rotation, the residents were comfortable performing a laparoscopic cholecystectomy (9.2), a hand-sewn anastomosis (8.7), and a stapled anastomosis (9.4). The residents found theses activities helpful in increasing order: VC (7.8), VR (8.0), BT (9.0), ES (9.7), OF (9.8), and AS (9.8). A 1-mo dedicated technical skills rotations was perceived to be extremely positive by the residents. The residents felt very comfortable performing a laparoscopic cholecystectomy, a hand-sewn anastomosis, and a stapled anastomosis. With the 80-h work week, alternatives to learning technical skills in the operating room are essential. Further studies need to be performed to determine if this rotation aids in accomplishing this goal. Copyright 2010. Published by Elsevier Inc.

  2. The effect of gender on early and intermediate results of endovascular aneurysm repair.

    PubMed

    Nordness, Paul J; Carter, Glen; Tonnessen, Britt; Charles Sternbergh, W; Money, Samuel R

    2003-11-01

    Results of endovascular aneurysm repair (EVAR) may be gender dependent. Between September 1997 and September 2001, 118 AneuRx aortic grafts were placed for aneurysmal disease. During this period, 17 females and 101 males were treated with this device. A prospective database was maintained and supplemented with retrospectively gathered information to evaluate early and mid-term end points. A total of 113 devices were deployed in 118 attempts. Length of procedure was greater for females (3.3 +/- 1.75 vs. 2.3 +/- 0.8 hr, p = 0.05) and they were more likely to have significant arterial dissections (12% vs. 1%, p = 0.05). The mortality rates at 1 month were 12% for females and 0% for males ( p = 0.02); the complication rates at 1 month were 41% for females and 15% for males ( p = 0.02). Although technical success was not significantly different between the sexes, assisted primary technical success (requiring endovascular assistance) and assisted secondary technical success (requiring open surgical assistance) were significantly different (71% vs. 96%, p = 0.003; and 76% vs. 98%, p = 0.004, respectively). Clinical success at 1 month was 59% for females and 84% for males ( p = 0.02). This difference was also significant when assessing 1-month assisted primary clinical success (59% vs. 90%, p = 0.003) and assisted secondary clinical success as well (71% vs. 96%, p = 0.003). Clinical success and assisted primary clinical success were not different at 6- or 12-month intervals, however, assisted secondary clinical successes differed at both time intervals (56% vs. 83%, p = 0.02; and 56% vs. 81%, p = 0.05, respectively). As-yet undetermined factors appear to predispose females to complications and technical difficulties in the short term. Endovascular and open procedures required to achieve ongoing clinical success in the following months appear to favor males to a greater degree than females.

  3. Predictors of Perioperative Stroke/Death after Carotid Artery Stenting: A Review Article

    PubMed Central

    AbuRahma, Ali F.

    2018-01-01

    Carotid artery stenting (CAS) has been recommended as an alternative treatment to carotid endarterectomy for patients with significant carotid stenosis. Only a few studies have analyzed clinical/anatomical and technical variables that affect perioperative outcomes of CAS. Following a comprehensive Medline search, it was reported that clinical factors, including age of >80 years, chronic renal failure, diabetes mellitus, symptomatic indications, and procedures performed within 2 weeks of transient ischemic attack symptoms, are associated with high perioperative stroke and death rates. They also highlighted that angiographic variables, e.g., ulcerated and calcified plaques, left carotid intervention, >90% stenosis, >10-mm target lesion length, ostial involvement, type III aortic arch, and >60°-angulated internal carotid and common carotid arteries, are predictors of increased stroke rates. Technical factors associated with increased perioperative risk of stroke include percutaneous transluminal angioplasty (PTA) without embolic protection devices, PTA before stent placement, and the use of multiple stents. This review describes the most widely quoted data in defining various predictors of perioperative stroke and death after CAS. (This is a review article based on the invited lecture of the 45th Annual Meeting of Japanese Society for Vascular Surgery.) PMID:29682104

  4. Human Factors Throughout the Life Cycle: Lessons Learned from the Shuttle Program. [Human Factors in Ground Processing

    NASA Technical Reports Server (NTRS)

    Kanki, Barbara G.

    2011-01-01

    With the ending of the Space Shuttle Program, it is critical that we not forget the Human Factors lessons we have learned over the years. At every phase of the life cycle, from manufacturing, processing and integrating vehicle and payload, to launch, flight operations, mission control and landing, hundreds of teams have worked together to achieve mission success in one of the most complex, high-risk socio-technical enterprises ever designed. Just as there was great diversity in the types of operations performed at every stage, there was a myriad of human factors that could further complicate these human systems. A single mishap or close call could point to issues at the individual level (perceptual or workload limitations, training, fatigue, human error susceptibilities), the task level (design of tools, procedures and aspects of the workplace), as well as the organizational level (appropriate resources, safety policies, information access and communication channels). While we have often had to learn through human mistakes and technological failures, we have also begun to understand how to design human systems in which individuals can excel, where tasks and procedures are not only safe but efficient, and how organizations can foster a proactive approach to managing risk and supporting human enterprises. Panelists will talk about their experiences as they relate human factors to a particular phase of the shuttle life cycle. They will conclude with a framework for tying together human factors lessons-learned into system-level risk management strategies.

  5. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. 75 FR 5225 - Professional Conduct for Practitioners: Rules, Procedures, Representation, and Appearances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-02

    ... Justice (DOJ); clarify who is authorized to represent applicants and petitioners in cases before DHS... regulations; make technical and procedural changes; and conform terminology. This rule enhances the integrity... existing regulations; and eliminates references to procedural matters that are solely within the authority...

  7. 14 CFR § 1240.109 - Hearing procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CONTRIBUTIONS Awards for Scientific and Technical Contributions § 1240.109 Hearing procedure. (a) An Oral... present evidence and arguments in support of the application. Evidence may be presented through means of...

  8. 14 CFR 1240.109 - Hearing procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Scientific and Technical Contributions § 1240.109 Hearing procedure. (a) An Oral hearing held by the Board... arguments in support of the application. Evidence may be presented through means of such witnesses, exhibits...

  9. Cryoablation of Osteoid Osteoma in the Pediatric and Adolescent Population.

    PubMed

    Whitmore, Morgan J; Hawkins, C Matthew; Prologo, J David; Marshall, Kelley W; Fabregas, Jorge A; Yim, Douglas B; Monson, David; Oskouei, Shervin V; Fletcher, Nicholas D; Williams, Roger S

    2016-02-01

    To evaluate the technical feasibility and clinical efficacy of osteoid osteoma (OO) cryoablation in a large, pediatric/adolescent cohort. An electronic medical record and imaging archive review was performed to identify all cryoablations performed for OOs between 2011 and 2015 at a single tertiary care pediatric hospital. The subsequent analysis included 29 patients with suspected OOs treated by cryoablation (age range, 3-18 y; mean age, 11.3 y; 17 boys; 12 girls). Conventional CT guidance was used in 22 procedures; cone-beam CT guidance was used in 7 procedures. Follow-up data were obtained via a standardized telephone questionnaire (23/29 patients; 79.3%) and clinical notes (5/29 patients; 17.2%). One patient was lost to follow-up. Technical success was achieved in 100% of patients (29/29). Immediate clinical success (cessation of pain and nonsteroidal antiinflammatory drug [NSAID] use within 1 mo after the procedure) was achieved in 27/28 patients (96.4%). Short-term clinical success (cessation of pain and NSAID use for > 3 mo after the procedure) was achieved in 24/25 patients (96%). Long-term clinical success (cessation of pain and NSAID use for > 12 mo after the procedure) was achieved in 19/21 patients (90.5%). Median pain scale score before the procedure was 10 (range, 5-10); median pain scale score after the procedure was 0 (range, 0-8; P < .0001). There were 6 minor complications (21%) and no major complications. Image-guided cryoablation is a technically feasible, clinically efficacious therapeutic option for children and adolescents with symptomatic OO. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  10. Meta-analysis of the technical performance of an imaging procedure: guidelines and statistical methodology.

    PubMed

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2015-02-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test-retest repeatability data for illustrative purposes. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Meta-analysis of the technical performance of an imaging procedure: Guidelines and statistical methodology

    PubMed Central

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2017-01-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test–retest repeatability data for illustrative purposes. PMID:24872353

  12. Three-dimensional path planning software-assisted transjugular intrahepatic portosystemic shunt: a technical modification.

    PubMed

    Tsauo, Jiaywei; Luo, Xuefeng; Ye, Linchao; Li, Xiao

    2015-06-01

    This study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS). 3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate the angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients. Failure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures. Adjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.

  13. Cost accounting in radiation oncology: a computer-based model for reimbursement.

    PubMed

    Perez, C A; Kobeissi, B; Smith, B D; Fox, S; Grigsby, P W; Purdy, J A; Procter, H D; Wasserman, T H

    1993-04-02

    The skyrocketing cost of medical care in the United States has resulted in multiple efforts in cost containment. The present work offers a rational computer-based cost accounting approach to determine the actual use of resources in providing a specific service in a radiation oncology center. A procedure-level cost accounting system was developed by using recorded information on actual time and effort spent by individual staff members performing various radiation oncology procedures, and analyzing direct and indirect costs related to staffing (labor), facilities and equipment, supplies, etc. Expenditures were classified as direct or indirect and fixed or variable. A relative value unit was generated to allocate specific cost factors to each procedure. Different costs per procedure were identified according to complexity. Whereas there was no significant difference in the treatment time between low-energy (4 and 6 MV) or high-energy (18 MV) accelerators, there were significantly higher costs identified in the operation of a high-energy linear accelerator, a reflection of initial equipment investment, quality assurance and calibration procedures, maintenance costs, service contract, and replacement parts. Utilization of resources was related to the complexity of the procedures performed and whether the treatments were delivered to inpatients or outpatients. In analyzing time motion for physicians and other staff, it was apparent that a greater effort must be made to train the staff to accurately record all times involved in a given procedure, and it is strongly recommended that each institution perform its own time motion studies to more accurately determine operating costs. Sixty-six percent of our facility's global costs were for labor, 20% for other operating expenses, 10% for space, and 4% for equipment. Significant differences were noted in the cost allocation for professional or technical functions, as labor, space, and equipment costs are higher in the latter. External beam treatment-related procedures accounted for more than 50% of all technical and professional revenues, simulation for 8% to 10%, and other physics/dosimetry procedures for 11% to 14% of revenues. Some discrepancies were identified between the actual cost and level of reimbursement of various procedures. Details are described in the manuscript. It is imperative to develop an equitable reimbursement system for radiation oncology services, based on cost accounting and other measures that may enhance productivity and reduce the cost per procedure unit, while at the same time preserving the highest quality of service provided to patients.

  14. The 'wayfinding' experience of family carers who learn to manage technical health procedures at home: a grounded theory study.

    PubMed

    McDonald, Janet; McKinlay, Eileen; Keeling, Sally; Levack, William

    2017-12-01

    With more care taking place in the home, family carers play an important role in supporting patients. Some family carers undertake technical health procedures generally managed by health professionals in hospital settings (e.g. managing a tracheostomy or enteral feeding). To explore how family carers learn to manage technical health procedures in order to help health professionals better understand and support this process. A grounded theory study using data from interviews with 26 New Zealand family carers who managed technical health procedures including nasogastric or gastrostomy feeding, stoma care, urinary catheterisation, tracheostomy management, intravenous therapy, diabetes management and complex wound dressings. Most (20 participants) were caring for their child and the remaining six for their spouse, parent or grandparent. Following grounded theory methods, each interview was coded soon after completion. Additional data were compared with existing material, and as analysis proceeded, initial codes were grouped into higher order concepts until a core concept was developed. Interviewing continued until no new ideas emerged and concepts were well defined. The core concept of 'wayfinding' indicates that the learning process for family carers is active, individualised and multi-influenced, developing over time as a response to lived experience. Health professional support was concentrated on the initial phase of carers' training, reducing and becoming more reactive as carers took responsibility for day-to-day management. Wayfinding involves self-navigation by carers, in contrast to patient navigator models which provide continuing professional assistance to patients receiving cancer or chronic care services. Wayfinding by carers raises questions about how carers should be best supported in their initial and ongoing learning as the management of these procedures changes over time. © 2017 Nordic College of Caring Science.

  15. Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center

    PubMed Central

    Ahn, Se Jin; Chung, Jin Wook; An, Sang Bu; Yin, Yong Hu; Jae, Hwan Jun; Park, Jae Hyung

    2012-01-01

    Objective To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate. PMID:22563269

  16. Effects of educational intervention on adherence to the technical recommendations for tracheobronchial aspiration in patients admitted to an intensive care unit

    PubMed Central

    de Lima, Erimara Dall'Agnol; Fleck, Caren Schlottefeld; Borges, Januário José Vieira; Condessa, Robledo Leal; Vieira, Sílvia Regina Rios

    2013-01-01

    Objective To evaluate the effectiveness of an educational intervention on healthcare professionals' adherence to the technical recommendations for tracheobronchial aspiration in intensive care unit patients. Methods A quasi-experimental study was performed to evaluate intensive care unit professionals' adherence to the tracheobronchial aspiration technical recommendations in intensive care unit patients both before and after a theoretical and practical educational intervention. Comparisons were performed using the chi-square test, and the significance level was set to p<0.05. Results A total of 124 procedures, pre- and post-intervention, were observed. Increased adherence was observed in the following actions: the use of personal protective equipment (p=0.01); precaution when opening the catheter package (p<0.001); the use of a sterile glove on the dominant hand to remove the catheter (p=0.003); the contact of the sterile glove with the catheter only (p<0.001); the execution of circular movements during the catheter removal (p<0.001); wrapping the catheter in the sterile glove at the end of the procedure (p=0.003); the use of distilled water, opened at the start of the procedure, to wash the connection latex (p=0.002); the disposal of the leftover distilled water at the end of the procedure (p<0.001); and the performance of the aspiration technique procedures (p<0.001). Conclusion There was a low adherence by health professionals to the preventive measures against hospital infection, indicating the need to implement educational strategies. The educational intervention used was shown to be effective in increasing adherence to the technical recommendations for tracheobronchial aspiration. PMID:23917976

  17. Technical skills acquisition in surgery-bound senior medical students: an evaluation of student assertiveness.

    PubMed

    Talbott, Vanessa A; Marks, Joshua A; Bodzin, Adam S; Comeau, Jason A; Maxwell, Pinckney J; Isenberg, Gerald A; Martin, Niels D

    2012-01-01

    To prepare students pursuing surgical careers, we devised a senior subinternship curriculum supplement that focused on the acquisition of technical skills required of surgical residents. We hypothesized that more assertive students, those that accomplished more of the curriculum, would perform better on a technical skills Objective Structured Clinical Examination (OSCE). Senior medical students rotating on their first general surgery subinternship were administered a 6-station OSCE on the first day of their subinternship and again during the final week of the month-long rotation. A self-directed, 38-task "scavenger hunt" representing common intern level clinical skills, procedures, and patient care activities was provided to each student. The study was performed at Jefferson Medical College, a large, private medical school in Philadelphia, PA. Forty-nine senior students completed surgical subinternships between July 2009 and September 2010, and participated both in the pre-/post-OSCEs and the scavenger hunt. Students performed significantly better on the post-rotation OSCE than on the pre-rotation OSCE; 70.2% ± 8.1% vs. 60.4% ± 12.0%, p < 0.0001. Assertiveness scores from the "scavenger hunt" did not correlate with final OSCE scores (r = -0.328, p = 0.25), and were negatively correlated with the change between pre- and post-OSCE scores (r = -0.573, p < 0.04). Individual student assertiveness scores were determined by the number of tasks completed over the course of the rotation. As surgical education becomes more streamlined with evolving work hour restrictions, medical school education is playing an increasingly pivotal role in preparing students for internship. In our study, individual assertiveness in completing structured self-directed learning tasks did not directly predict the acquisition of proficiency in technical skills. We feel assertiveness is overshadowed by other factors that may carry more weight in terms of technical skills acquisition. Further studies are required to delineate these factors and ultimately enhance technical skills acquisition during medical school. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jalaeian, Hamed, E-mail: hjalaeia@umn.edu; Talaie, Reza; D’Souza, Donna

    PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in themore » conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.« less

  19. Impact of Medicare Advantage penetration and hospital competition on technical efficiency of nursing care in US intensive care units.

    PubMed

    Min, Ari; Scott, Linda D; Park, Chang; Vincent, Catherine; Ryan, Catherine J; Lee, Taewha

    2018-04-10

    This study aimed to evaluate technical efficiency of US intensive care units and determine the effects of environmental factors on technical efficiency in providing quality of nursing care. Data were obtained from the 2014 National Database of Nursing Quality Indicators and the Centers for Medicare and Medicaid Services. Data envelopment analysis was used to estimate technical efficiency for each intensive care unit. Multilevel modeling was used to determine the effects of environmental factors on technical efficiency. Overall, Medicare Advantage penetration and hospital competition in a market did not create pressure for intensive care units to become more efficient by reducing their inputs. However, these 2 environmental factors showed positive influences on technical efficiency in intensive care units with certain levels of technical efficiency. The implications of the study results for management strategies and health policy may vary according to the levels of technical efficiency in intensive care units. Further studies are needed to examine why and how intensive care units with particular levels of technical efficiency are differently affected by certain environmental factors. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Training Manuals and Technical Publications.

    ERIC Educational Resources Information Center

    Army Test and Evaluation Command, Aberdeen Proving Ground, MD.

    The objective of the Materiel Test Procedure is to describe methods for determining the need for adequacy of comprehensiveness, and clarity of training manuals and technical publications (or other pertinent types of literature) relating to the ammunition or ammunition components being tested. (Author)

  1. TECHNICAL GUIDANCE DOCUMENT: QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES

    EPA Science Inventory

    This Technical Guidance Document provides comprehensive guidance on procedures for quality assurance and quality control for waste containment facilities. he document includes a discussion of principles and concepts, compacted soil liners, soil drainage systems, geosynthetic drai...

  2. TECHNICAL GUIDANCE DOCUMENT: QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES

    EPA Science Inventory

    This Technical Guidance Document provides comprehensive guidance on procedures for quality assurance and quality control for waste containment facilities. The document includes a discussion of principles and concepts, compacted soil liners, soil drainage systems, geosynthetic dr...

  3. Technical Criteria and Procedures for Evaluating the Crashworthiness and Occupant Protection Performance of Alternatively Designed Passenger Rail Equipment for Use in Tier I Service

    DOT National Transportation Integrated Search

    2011-10-01

    Criteria and procedures have been developed for assessing crashworthiness and occupant protection performance of alternatively designed trainsets to be used in Tier I (not exceeding 125 mph) passenger service. These criteria and procedures take advan...

  4. Space Geodesy Project Information and Configuration Management Procedure

    NASA Technical Reports Server (NTRS)

    Merkowitz, Stephen M.

    2016-01-01

    This plan defines the Space Geodesy Project (SGP) policies, procedures, and requirements for Information and Configuration Management (CM). This procedure describes a process that is intended to ensure that all proposed and approved technical and programmatic baselines and changes to the SGP hardware, software, support systems, and equipment are documented.

  5. 40 CFR 53.43 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedures. 53.43 Section 53.43... PM10 § 53.43 Test procedures. (a) Sampling effectiveness—(1) Technical definition. The ratio (expressed... or filters to the mass concentration of particles of the same size approaching the sampler. (2) Test...

  6. 40 CFR 53.43 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test procedures. 53.43 Section 53.43... PM10 § 53.43 Test procedures. (a) Sampling effectiveness—(1) Technical definition. The ratio (expressed... or filters to the mass concentration of particles of the same size approaching the sampler. (2) Test...

  7. Using Three-Dimensional Interactive Graphics To Teach Equipment Procedures.

    ERIC Educational Resources Information Center

    Hamel, Cheryl J.; Ryan-Jones, David L.

    1997-01-01

    Focuses on how three-dimensional graphical and interactive features of computer-based instruction can enhance learning and support human cognition during technical training of equipment procedures. Presents guidelines for using three-dimensional interactive graphics to teach equipment procedures based on studies of the effects of graphics, motion,…

  8. Student Services Program Planning and Evaluation: Responsibility, Procedures, Instrument, and Guidelines.

    ERIC Educational Resources Information Center

    Repp, Charles A.; Brach, Ronald C.

    The manual provides a rationale, procedural guidelines, time-schedules, instruments, and supporting documentation for student services program evaluation at SUNY Agricultural and Technical College, Delhi. Six procedural guidelines include: (1) all programs and services should be evaluated at least once every four years, with provision for annual…

  9. Classification of municipal occupations.

    PubMed

    Ilmarinen, J; Suurnäkki, T; Nygård, C H; Landau, K

    1991-01-01

    Eighty-eight job titles were analyzed with the "ergonomic job analysis procedure" [Arbeitswissenschaftliche Erhebungsverfahren zur Tätigkeits-analyse abbreviated (AET) in German]. The objective was to classify the wide range of municipal jobs into homogeneous groups according to job demand and to provide better possibilities to study the relationships between work and health among the aging municipal working population. Altogether 216 items were classified. First, a hierarchical cluster analysis was made, and a dendrogram of the analyzed job titles was drawn. Second, a profile analysis was done in which the single items were grouped into 39 sum items, and a graphic profile was drawn. Finally, the stress factors were listed and drawn in ranking order. The cluster analysis formed 13 groups. Groups exposed to the highest stress factor level were kitchen supervisors, dentists, and physicians. More than 10 stress factors (greater than 50% of the maximum) were found in nursing, administration, installation, transport, and technical supervision.

  10. Naval Training Equipment Center Index of Technical Reports,

    DTIC Science & Technology

    1982-09-01

    741 RECOMMENDED PROCEDURES AND TRAINING NAVAL TRAINING AIDS. tAMPHIBIOUS OPERATIONS PROCEDURES AND RESEARCH PLANNING AD- 642 590 TRAINING DEVICES FOR...PROCEDURES AND RESEARCH PLANNING OBSERVATION AND FIRE CONTROL WITH FOR ANTI-AIR WARFARE TRAINING SPECIFIC REFERENCE TO THE TRAINING *AMPUTEES PROGRAM...619 AD- 707 757 NAVAL PERSONNEL *COMMUNICATION SATELLITES PROCEDURES AND RESEARCH PLANNING *COMBUSTION PRODUCTS Computer Managed Instruction by FOR

  11. CAT-ASVAB Technical Bulletin Number 1

    DTIC Science & Technology

    2006-03-01

    CAT -ASVAB Technical Bulletin #1 Personnel Testing Division Defense Manpower Data Center March 2006 Report...2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE CAT -ASVAB Technical Bulletin #1 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...Hetter, R. D. "Psychometric Procedures for Administering CAT -ASVAB" (pp. 131-140) Chapter 4 Hetter, R. D., & Sympson J. B. "Item Exposure

  12. [The problems of assessment of the high noise impact on the experts of the Air Force].

    PubMed

    Zinkin, V N; Sheshegov, P M

    2012-01-01

    Air Force specialists are exposed to high intensity noise levels exceeded the maximum permissible levels. Infrasound as a productive factor in accordance with the general technical requirements (OTT) Air Force-86 is not included in the list of standardized factors. The adverse acoustic environment makes the risk of occupational (sensorineural deafness) and professionally-related diseases of the nervous and cardiovascular systems. The system of physical fitness for military service in the Air Force and serving in the Air Force with high-intensity sources of noise, the system of treatment and preventive measures for adverse effects of noise and the procedure for examination of persons with diseases caused by the influence of noise are needed to be reviewed in accordance with the existing state legislative frameworks.

  13. A perspective of percutaneous transluminal angioplasty.

    PubMed

    Stanson, A W

    1983-01-01

    PTA is a relatively new procedure which is still evolving. More technical improvements are needed. Stiffer balloon plastics and devices to measure arterial wall compliance during balloon inflation are predicted to lead to better long-term success rates. Increasing case numbers provide greater expertise and subsequent refinements in performance and case selection. These factors will lead to improved statistics. Other features of overall patient care must be considered also. The procedure is easy for patients to tolerate, and they can return to activities and work in three or four days. The overall cost is much cheaper than surgery, even at a conservative success rate of 65 percent. There is minimal risk and morbidity, and virtually no mortality. PTA can be repeated if the lesion recurs. Severe complications are rare and almost always surgically treatable. If PTA fails to achieve success, a traditional surgical procedure can be performed. Percutaneous transluminal angioplasty is an important therapeutic alternative to traditional medical and surgical treatment for occlusive arterial disease. It can save legs, veins, time, and money. We need to refine and accurately record the use of this procedure. Total cooperation among clinicians, surgeons, and radiologists is essential for proper utilization of PTA.

  14. Percutaneous radiofrequency ablation of hepatic tumours: factors affecting technical failure of artificial ascites formation using an angiosheath.

    PubMed

    Kang, T W; Lee, M W; Hye, M J; Song, K D; Lim, S; Rhim, H; Lim, H K; Cha, D I

    2014-12-01

    To evaluate the technical feasibility of artificial ascites formation using an angiosheath before percutaneous radiofrequency ablation (RFA) for hepatic tumours and to determine predictive factors affecting the technical failure of artificial ascites formation. This retrospective study was approved by the institutional review board. One hundred and thirteen patients underwent percutaneous RFA of hepatic tumours after trying to make artificial ascites using an angiosheath to avoid collateral thermal damage. The technical success rate of making artificial ascites using an angiosheath and conversion rate to other techniques after initial failure of making artificial ascites were evaluated. The technical success rate for RFA was assessed. In addition, potential factors associated with technical failure including previous history of transcatheter arterial chemoembolization (TACE) or RFA, type of abdominal surgery, and adjacent perihepatic structures were reviewed. Predictive factors for the technical failure of artificial ascites formation were analysed using multivariate analysis. The technical success rates of artificial ascites formation by angiosheath and that of RFA were 84.1% (95/113) and 97.3% (110/113), respectively. The conversion rate to other techniques after the failure of artificial ascites formation using an angiosheath was 15.9% (18/113). Previous hepatic resection was the sole independent predictive factor affecting the technical failure of artificial ascites formation (p<0.001, odds ratio = 29.03, 95% confidence interval: 4.56-184.69). Making artificial ascites for RFA of hepatic tumours using an angiosheath was technically feasible in most cases. However, history of hepatic resection was a significant predictive factor affecting the technical failure of artificial ascites formation. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. Analysis of localizer and glide slope Flight Technical Error

    DOT National Transportation Integrated Search

    2008-12-09

    A new wake turbulence procedure has been developed that permits two dependent arrival traffic streams during instrument meteorological conditions : to runways with centerline separations less than 2500 ft. For the proposed procedure, aircraft approac...

  16. Accessible Electronic and Information Technology: Standards, Procedures, and Guidance

    EPA Pesticide Factsheets

    Defines electronic and information technology (EIT), and the technical and functional performance criteria for EIT to comply with Section 508 accessibility standards. Includes EPA procedures for EIT approval, 508 complaints, and undue burden justification.

  17. Validation of the grown-ups with congenital heart disease score.

    PubMed

    Hörer, Jürgen; Roussin, Régine; LeBret, Emanuel; Ly, Mohamed; Abdullah, Jarrah; Marzullo, Rafaella; Pabst von Ohain, Jelena; Belli, Emre

    2018-06-01

    Adults with congenital heart disease in need of heart surgery frequently present with significant comorbidity. Furthermore, additional technical difficulties often related to redo operations increase the risk for postoperative mortality and morbidity. Hence, next to the type of the procedure, additional procedure-dependent and procedure-independent factors have to be considered for risk evaluation. The recently proposed grown-ups with congenital heart disease (GUCH) mortality and morbidity scores account for these additional risk factors. We sought to validate their predictive power in a large population operated in a single centre. Data of all consecutive patients aged 18 years or more, who underwent surgery for congenital heart disease between 2005 and 2016, were collected. Mortality was defined as hospital mortality or mortality within 30 days following surgery. Morbidity was defined as occurrence of one or more of the following complications: renal failure requiring dialysis, neurologic deficit persisting at discharge, atrioventricular block requiring permanent pacemaker implantation, mechanical circulatory support, phrenic nerve injury and unplanned reoperation. The discriminatory power of the GUCH scores was assessed using the area under the receiver operating characteristics curve (c-index, including 95% CI). Eight hundred and twenty-four operations were evaluated. Additional procedure-dependent and procedure-independent factors, as defined in the GUCH scores, were present in 165 patients (20.0%) and 544 patients (66.0%), respectively. Hospital mortality and morbidity was 3.4% and 10.0%, respectively. C-index for GUCH mortality score was 0.809 (0.742-0.877). C-index for GUCH morbidity score was 0.676 (0.619-0.734). We could confirm the good predictive power of the GUCH mortality score for postoperative mortality in a large population of adults with congenital heart disease. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Development and Validation of a Novel Scoring System for Predicting Technical Success of Chronic Total Occlusion Percutaneous Coronary Interventions: The PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) Score.

    PubMed

    Christopoulos, Georgios; Kandzari, David E; Yeh, Robert W; Jaffer, Farouc A; Karmpaliotis, Dimitri; Wyman, Michael R; Alaswad, Khaldoon; Lombardi, William; Grantham, J Aaron; Moses, Jeffrey; Christakopoulos, Georgios; Tarar, Muhammad Nauman J; Rangan, Bavana V; Lembo, Nicholas; Garcia, Santiago; Cipher, Daisha; Thompson, Craig A; Banerjee, Subhash; Brilakis, Emmanouil S

    2016-01-11

    This study sought to develop a novel parsimonious score for predicting technical success of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) performed using the hybrid approach. Predicting technical success of CTO PCI can facilitate clinical decision making and procedural planning. We analyzed clinical and angiographic parameters from 781 CTO PCIs included in PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) using a derivation and validation cohort (2:1 sampling ratio). Variables with strong association with technical success in multivariable analysis were assigned 1 point, and a 4-point score was developed from summing all points. The PROGRESS CTO score was subsequently compared with the J-CTO (Multicenter Chronic Total Occlusion Registry in Japan) score in the validation cohort. Technical success was 92.9%. On multivariable analysis, factors associated with technical success included proximal cap ambiguity (beta coefficient [b] = 0.88), moderate/severe tortuosity (b = 1.18), circumflex artery CTO (b = 0.99), and absence of "interventional" collaterals (b = 0.88). The resulting score demonstrated good calibration and discriminatory capacity in the derivation (Hosmer-Lemeshow chi-square = 2.633; p = 0.268, and receiver-operator characteristic [ROC] area = 0.778) and validation (Hosmer-Lemeshow chi-square = 5.333; p = 0.070, and ROC area = 0.720) subset. In the validation cohort, the PROGRESS CTO and J-CTO scores performed similarly in predicting technical success (ROC area 0.720 vs. 0.746, area under the curve difference = 0.026, 95% confidence interval = -0.093 to 0.144). The PROGRESS CTO score is a novel useful tool for estimating technical success in CTO PCI performed using the hybrid approach. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. [Low-field magnetic resonance imaging for rheumatoid arthritis].

    PubMed

    Ostendorf, B; Edelmann, E; Kellner, H; Scherer, A

    2010-02-01

    Magnetic resonance imaging (MRI) as a cross-sectional imaging procedure allows a three-dimensional representation of musculature, ligaments, tendons, capsules, synovial membranes, bones and cartilage with high resolution quality. An activity assessment is further possible by application of a contrast medium (gadolinium-DTPA) to differentiate between active and chronic inflammatory processes. Evidence of a bone marrow edema detected by MRI in patients with rheumatoid arthritis (RA) can be interpreted as a prognostic and predictive factor for the development of bone erosions. On the basis of these advantages MRI is being employed more and more in the early diagnosis of inflammatory joint diseases. Semi-quantitative scores for analysis and grading of findings have already been developed and are in clinical use. Because MRI technical performances are invariably reproducible they can be practically retrieved in the course of examination which is particularly relevant in rheumatology. Therapy response or progression can thus be adequately displayed. Open, dedicated low-field MRI with a low signal strength of 0.2 Tesla (T) has been known since the 90s and now represents new MRI examination options in rheumatology. Smaller devices with lower acquisition and maintenance expenses as well as considerably more convenience due to the device itself result in a higher subjective acceptability by the patients as well as objectively more data records of low-field MRI scans of RA, which underline the significance of this new technical method. The German Society for Rheumatology (DGRh), represented by the Committee for "Diagnostic Imaging", meets this development with the release of recommendations and standards for the procedures of low-field MRI and their scoring and summarizes the most important technical data and information on clinical indications.

  20. Multimodal Analgesia in Breast Surgical Procedures: Technical and Pharmacological Considerations for Liposomal Bupivacaine Use

    PubMed Central

    Newman, Martin I.; Seeley, Neil; Hutchins, Jacob; Smith, Kevin L.; Mena, Gabriel; Selber, Jesse C.; Saint-Cyr, Michel H.; Gadsden, Jeffrey C.

    2017-01-01

    Enhanced recovery after surgery is a multidisciplinary perioperative clinical pathway that uses evidence-based interventions to improve the patient experience as well as increase satisfaction, reduce costs, mitigate the surgical stress response, accelerate functional recovery, and decrease perioperative complications. One of the most important elements of enhanced recovery pathways is multimodal pain management. Herein, aspects relating to multimodal analgesia following breast surgical procedures are discussed with the understanding that treatment decisions should be individualized and guided by sound clinical judgment. A review of liposomal bupivacaine, a prolonged-release formulation of bupivacaine, in the management of postoperative pain following breast surgical procedures is presented, and technical guidance regarding optimal administration of liposomal bupivacaine is provided. PMID:29062649

  1. Privacy and security compliance in the E-healthcare marketplace.

    PubMed

    Lutes, M

    2000-03-01

    Complying with security and privacy regulations proposed by HHS in response to the Health Insurance Portability and Accountability Act (HIPAA) will require healthcare managers to address both internal and external business interactions and initiatives. The proposed regulations mandate certain procedures regarding administration, physical safeguards, technical security for data integrity and confidentiality, and technical security against unauthorized access. In particular, the proposed regulations require organizations to contractually ensure that vendors adhere to the regulations. Healthcare organizations also must implement training procedures for staff members who have contact with protected health information and designate a privacy officer to guard against improper disclosure of such information. Documented policies for organizational decision making are vital to an organization's efforts to implement procedures for compliance with the regulations.

  2. [Robotic surgery -- the modern surgical treatment of prostate cancer].

    PubMed

    Szabó, Ferenc János; Alexander, de la Taille

    2014-09-01

    Minimally invasive laparoscopic surgery replaces many open surgery procedures in urology due to its advantages concerning post-operative morbidity. However, the technical challenges and need of learning have limited the application of this method to the work of highly qualified surgeons. The introduction of da Vinci surgical system has offered important technical advantages compared to the laparoscopic surgical procedure. Robot-assisted radical prostatectomy became a largely accepted procedure. It has paved the way for urologists to start other, more complex operations, decreasing this way the operative morbidity. The purpose of this article is to overview the history of robotic surgery, its current and future states in the treatment of the cancer. We present our robot-assisted radical prostatectomy and the results.

  3. A Schema Theory Account of Some Cognitive Processes in Complex Learning. Technical Report No. 81.

    ERIC Educational Resources Information Center

    Munro, Allen; Rigney, Joseph W.

    Procedural semantics models have diminished the distinction between data structures and procedures in computer simulations of human intelligence. This development has theoretical consequences for models of cognition. One type of procedural semantics model, called schema theory, is presented, and a variety of cognitive processes are explained in…

  4. Factors Influencing the Pursuit of IT Certifications: A Study of Minnesota Public Community and Technical College Students

    ERIC Educational Resources Information Center

    Wilkens, Eric S.

    2013-01-01

    This quantitative study attempted to understand the factors that influence Minnesota community and technical college students to pursue Information Technology (IT) certification. The study investigated the problem of determining the factors that influence Minnesota community and technical college students to pursue IT certification along with…

  5. 47 CFR 15.611 - General technical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false General technical requirements. 15.611 Section 15.611 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Access... shut-off procedure, by the use of a non-volatile memory, or some other method, to immediately restore...

  6. 78 FR 3893 - Enbridge Energy, Limited Partnership; Notice of Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-17

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. IS13-17-000] Enbridge Energy... Energy, Limited Partnership's proposed revision to its downstream Nomination Verification Procedure. \\1\\ Enbridge Energy, Limited Partnership, 141 FERC ] 61,246 (2012). Take notice that a technical conference...

  7. A technical report on structural evaluation of the Meade County reinforced concrete bridge.

    DOT National Transportation Integrated Search

    2009-01-01

    This is a technical report on the first phase of the evaluation of the Meade County reinforced concrete bridge. : The first three chapters introduce the main problem and provide a general review of the existing evaluation : methods and the procedures...

  8. [A technical modification of the use of Dwyer's equipment].

    PubMed

    Carlioz, H; Damsin, J P

    1991-01-01

    Dwyer's technique for correction and anterior fusion of the spine was improved by using lockers at the level of each screw. So, like with the Zielke's technic this procedure allowed a global progressive and controllable correction and a real derotation of the spine.

  9. 14 CFR 21.601 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PROCEDURES FOR PRODUCTS AND PARTS Technical Standard Order Authorizations § 21.601 Applicability. (a) This... requirements for the issuance of a letter of Technical Standard Order design approval. (b) For the purpose of..., articles means materials, parts, processes, or appliances) used on civil aircraft. (2) A TSO authorization...

  10. Predicting Influential Factors of Secondary Career and Technical Education Teachers' Intent to Stay in the Profession

    ERIC Educational Resources Information Center

    Dainty, Julie D.

    2012-01-01

    Retaining highly qualified career and technical education teachers is important in maintaining and growing quality secondary career and technical education programs. Therefore, the purpose of this study was to identify factors contributing to teacher retention specifically in the area of career and technical education (CTE) and determine…

  11. 48 CFR 242.7401 - Procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Procedures. 242.7401 Section 242.7401 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT CONTRACT ADMINISTRATION AND AUDIT SERVICES Technical Representation at...

  12. Percutaneous Coronary Revascularization for Chronic Total Occlusions: A Novel Predictive Score of Technical Failure Using Advanced Technologies.

    PubMed

    Galassi, Alfredo R; Boukhris, Marouane; Azzarelli, Salvatore; Castaing, Marine; Marzà, Francesco; Tomasello, Salvatore D

    2016-05-09

    The aims of this study were to describe the 10-year experience of a single operator dedicated to chronic total occlusion (CTO) and to establish a model for predicting technical failure. During the last decade, the interest in percutaneous coronary interventions (PCIs) of chronic total occlusions (CTOs) has increased, allowing the improvement of success rate. One thousand nineteen patients with CTO underwent 1,073 CTO procedures performed by a single CTO-dedicated operator. The study population was subdivided into 2 groups by time period: period 1 (January 2005 to December 2009, n = 378) and period 2 (January 2010 to December 2014, n = 641). Observations were randomly assigned to a derivation set and a validation set (in a 2:1 ratio). A prediction score was established by assigning points for each independent predictor of technical failure in the derivation set according to the beta coefficient and summing all points accrued. Lesions attempted in period 2 were more complex in comparison with those in period 1. Compared with period 1, both technical and clinical success rates significantly improved (from 87.8% to 94.4% [p = 0.001] and from 77.6% to 89.9% [p < 0.001], respectively). A prediction score for technical failure including age ≥75 years (1 point), ostial location (1 point), and collateral filling Rentrop grade <2 (2 points) was established, stratifying procedures into 4 difficulty groups: easy (0), intermediate (1), difficult (2), and very difficult (3 or 4), with decreasing technical success rates. In derivation and validation sets, areas under the curve were comparable (0.728 and 0.772, respectively). With growing expertise, the success rate has increased despite increasing complexity of attempted lesions. The established model predicted the probability of technical failure and thus might be applied to grading the difficulty of CTO procedures. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Vasectomy reversal: a clinical update

    PubMed Central

    Patel, Abhishek P; Smith, Ryan P

    2016-01-01

    Vasectomy is a safe and effective method of contraception used by 42–60 million men worldwide. Approximately 3%–6% of men opt for a vasectomy reversal due to the death of a child or divorce and remarriage, change in financial situation, desire for more children within the same marriage, or to alleviate the dreaded postvasectomy pain syndrome. Unlike vasectomy, vasectomy reversal is a much more technically challenging procedure that is performed only by a minority of urologists and places a larger financial strain on the patient since it is usually not covered by insurance. Interest in this procedure has increased since the operating microscope became available in the 1970s, which consequently led to improved patency and pregnancy rates following the procedure. In this clinical update, we discuss patient evaluation, variables that may influence reversal success rates, factors to consider in choosing to perform vasovasostomy versus vasoepididymostomy, and the usefulness of vasectomy reversal to alleviate postvasectomy pain syndrome. We also review the use of robotics for vasectomy reversal and other novel techniques and instrumentation that have emerged in recent years to aid in the success of this surgery. PMID:26975488

  14. Battery Test Manual For Electric Vehicles, Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christophersen, Jon P.

    2015-06-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Electric Vehicles (EV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for EVs. However, it does share some methods described in the previously published battery test manual for plug-in hybrid electric vehicles. Due to the complexity of some of themore » procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Chul Bae of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).« less

  15. Three-Dimensional Path Planning Software-Assisted Transjugular Intrahepatic Portosystemic Shunt: A Technical Modification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsauo, Jiaywei, E-mail: 80732059@qq.com; Luo, Xuefeng, E-mail: luobo-913@126.com; Ye, Linchao, E-mail: linchao.ye@siemens.com

    2015-06-15

    PurposeThis study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS).Methods3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate themore » angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients.ResultsFailure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures.ConclusionsAdjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.« less

  16. Virtual reality laparoscopy: which potential trainee starts with a higher proficiency level?

    PubMed

    Paschold, M; Schröder, M; Kauff, D W; Gorbauch, T; Herzer, M; Lang, H; Kneist, W

    2011-09-01

    Minimally invasive surgery requires technical skills distinct from those used in conventional surgery. The aim of this prospective study was to identify personal characteristics that may predict the attainable proficiency level of first-time virtual reality laparoscopy (VRL) trainees. Two hundred and seventy-nine consecutive undergraduate medical students without experience attended a standardized VRL training. Performance data of an abstract and a procedural task were correlated with possible predictive factors providing potential competence in VRL. Median global score requirement status was 86.7% (interquartile range (IQR) 75-93) for the abstract task and 74.4% (IQR 67-88) for the procedural task. Unadjusted analysis showed significant increase in the global score in both tasks for trainees who had a gaming console at home and frequently used it as well as for trainees who felt self-confident to assist in a laparoscopic operation. Multiple logistic regression analysis identified frequency of video gaming (often/frequently vs. rarely/not at all, odds ratio: abstract model 2.1 (95% confidence interval 1.2; 3.6), P = 0.009; virtual reality operation procedure 2.4 (95% confidence interval 1.3; 4.2), P = 0.003) as a predictive factor for VRL performance. Frequency of video gaming is associated with quality of first-time VRL performance. Video game experience may be used as trainee selection criteria for tailored concepts of VRL training programs.

  17. Identification of non-technical skills from the resilience engineering perspective: a case study of an electricity distributor.

    PubMed

    Wachs, Priscila; Righi, Angela Weber; Saurin, Tarcisio Abreu

    2012-01-01

    Training in non-technical skills (NTS) does not usually question the design of the work system, and thus focuses narrowly on workers as the unit of analysis. This study discusses how the identification of NTS, a major step for developing an NTS training program, might be re-interpreted from the perspective of resilience engineering (RE). This discussion is based on a case study of identifying NTS for electricians who perform emergency maintenance activities in an electricity distribution power line. The results of the case study point out that four data analysis procedures might operationalize the RE perspective: (a) identifying factors that make the work difficult and which could be integrated into NTS training scenarios; (b) identifying recommendations for re-designing the system, in order either to reduce or eliminate the need for NTS; (c) classifying the NTS into pragmatic categories, which are meaningful for workers; and (d) regarding the identification of NTS as an opportunity to give visibility to adaptations carried out by workers.

  18. [Ambulatory laparoscopic cholecystectomy by minilaparoscopy versus traditional multiport ambulatory laparoscopic cholecystectomy. Prospective randomized trial].

    PubMed

    Planells Roig, Manuel; Arnal Bertomeu, Consuelo; Garcia Espinosa, Rafael; Cervera Delgado, Maria; Carrau Giner, Miguel

    2016-02-01

    Difference analysis of ambulatorization rate, pain, analgesic requirements and daily activities recovery in patients undergoing laparoscopic cholecystectomy with standard multiport access (CLMP) versus a minilaparoscopic, 3mm size, technique. Prospective randomized trial of 40 consecutive patients undergoing laparoscopic cholecystectomy. Comparison criteria included predictive ultrasound factors of difficult cholecystectomy, previous history of complicated biliary disease and demographics. Results are analyzed in terms of ambulatorization rate, pain, analgesic requirements, postoperative recovery, technical difficulty, hemorrhage intensity, overnight stay, readmission rate and total or partial conversion. Both procedures were similar in surgery time, technical score and hemorrhage score. MLC was associated with similar ambulatorization rate, 85%, and over-night stay 15%, with only 15% partial conversion rate. MLC showed less postoperative pain (P=.026), less analgesic consumption (P=.006) and similar DAR (P=.879). MLC is similar to CLMP in terms of ambulatorization with less postoperative pain and analgesic requirements without differences in postoperative recovery. Copyright © 2014 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Technical analysis of the Slosson Written Expression Test.

    PubMed

    Erford, Bradley T; Hofler, Donald B

    2004-06-01

    The Slosson Written Expression Test was designed to assess students ages 8-17 years at risk for difficulties in written expression. Scores from three independent samples were used to evaluate the test's reliability and validity for measuring students' written expression. Test-retest reliability of the SWET subscales ranged from .80 to .94 (n = 151), and .95 for the Written Expression Total Standard Scores. The median alternate-form reliability for students' Written Expression Total Standard Scores was .81 across the three forms. Scores on the Slosson test yielded concurrent validity coefficients (n = 143) of .60 with scores from the Woodcock-Johnson: Tests of Achievement-Third Edition Broad Written Language Domain and .49 with scores on the Test of Written Language-Third Edition Spontaneous Writing Quotient. Exploratory factor analytic procedures suggested the Slosson test is comprised of two dimensions, Writing Mechanics and Writing Maturity (47.1% and 20.1% variance accounted for, respectively). In general, the Slosson Written Expression Test presents with sufficient technical characteristics to be considered a useful written expression screening test.

  20. Non-invasive Renal Denervation: Update on External Ultrasound Approaches.

    PubMed

    Schmieder, Roland E; Ott, Christian; Bramlage, Peter

    2016-06-01

    In the last decade, intravenous renal denervation (RDN) has emerged as an alternative to pharmacological treatment in patients with resistant hypertension, but currently involves an invasive and technically challenging procedure. The Surround Sound™ system utilises externally delivered ultrasound to achieve RDN using a completely non-invasive, automated real-time tracking system coupled with a therapeutic delivery module thereby addressing these limitations. A brief history, technical overview and summary of preclinical and clinical studies of the KonaMedical Surround Sound™ system are presented. A literature search using the terms "renal denervation", "resistant hypertension" and "external ultrasound" was performed using PubMed, and references retrieved were selected based on relevancy and year of publication (date range 1991-2015). The Surround Sound™ system appears to be a promising approach to RDN which eliminates several of the factors currently limiting the intravenous approach. So far, it has demonstrated efficacy for reducing blood pressure in resistant hypertension patients with minimal adverse effects. Several double-blind, sham-controlled clinical trials are currently underway to confirm the validity of these findings.

  1. [Management of technology in intensive care].

    PubMed

    Madureira, C R; Veiga, K; Sant'ana, A F

    2000-12-01

    The lives of hospitalized patients depend on diagnostic-therapeutic procedures and on the care provided by the health team. It also depends on the quality and availability of factors such as: physical structure and material and human and financial resources. The need to optimize these resources and re-establish patients' health has brought about the Intensive Care Units (ICU), whose design must consider the physical environment and clinical equipment which are indispensable in health care. Aiming at identifying the level of knowledge of health professionals as to technical and operational information in equipment manuals and the perception of the interviewed professionals in relation to the adequacy of the physical and electrical installations of such units, we conducted a descriptive study in an ICU of a public hospital in Salvador, Brazil. The results show that such installations were considered to be unsuitable for the safe development of activities and that most of the health team members did not know the technical or operational specifications in the equipment manuals.

  2. Escalating Role of Piezosurgery in Dental Therapeutics

    PubMed Central

    Masamatti, Sujata Surendra; Kumar, Ashish

    2014-01-01

    Dentistry, an art in science and tranquilizer in medicine, has seen a lot of changing concepts over a decade and one such novel innovation is piezosurgery. Piezosurgery is a true revolution in bone surgery as it fulfils both biological and technical criteria. It has a variety of applications ranging from minor surgical procedures to complex implantology, plastic and reconstructive surgeries. Piezosurgery uses a low frequency modulated ultrasonic insert which produces microvibrations in the range of 60-200micro meter/sec and leads to safe and precise bony incision without damaging underlying vital structures like nerves, mucosa and vessels. It overcomes technical difficulties such as visibility by producing bloodless field during surgery and removes debris simultaneously through internal irrigation mechanism. The soft tissues remain safe and biological factors like release of certain cytokines promote bone healing and enhance patients recovery. This critical review outweighs piezosurgery over traditional tools and emphasizes on its clinical and biological aspects contributing to beneficial dental health. PMID:25478473

  3. Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

    PubMed Central

    Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin

    2015-01-01

    Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380

  4. Reliable assessment of laparoscopic performance in the operating room using videotape analysis.

    PubMed

    Chang, Lily; Hogle, Nancy J; Moore, Brianna B; Graham, Mark J; Sinanan, Mika N; Bailey, Robert; Fowler, Dennis L

    2007-06-01

    The Global Operative Assessment of Laparoscopic Skills (GOALS) is a valid assessment tool for objectively evaluating the technical performance of laparoscopic skills in surgery residents. We hypothesized that GOALS would reliably differentiate between an experienced (expert) and an inexperienced (novice) laparoscopic surgeon (construct validity) based on a blinded videotape review of a laparoscopic cholecystectomy procedure. Ten board-certified surgeons actively engaged in the practice and teaching of laparoscopy reviewed and evaluated the videotaped operative performance of one novice and one expert laparoscopic surgeon using GOALS. Each reviewer recorded a score for both the expert and the novice videotape reviews in each of the 5 domains in GOALS (depth perception, bimanual dexterity, efficiency, tissue handling, and overall competence). The scores for the expert and the novice were compared and statistically analyzed using single-factor analysis of variance (ANOVA). The expert scored significantly higher than the novice did in the domains of depth perception (p = .005), bimanual dexterity (p = .001), efficiency (p = .001), and overall competence ( p = .001). Interrater reliability for the reviewers of the novice tape was Cronbach alpha = .93 and the expert tape was Cronbach alpha = .87. There was no difference between the two for tissue handling. The Global Operative Assessment of Laparoscopic Skills is a valid, objective assessment tool for evaluating technical surgical performance when used to blindly evaluate an intraoperative videotape recording of a laparoscopic procedure.

  5. ONE-DIMENSIONAL HYDRODYNAMIC/SEDIMENT TRANSPORT MODEL FOR STREAM NETWORKS: TECHNICAL REPORT

    EPA Science Inventory

    This technical report describes a new sediment transport model and the supporting post-processor, and sampling procedures for sediments in streams. Specifically, the following items are described herein:

    EFDC1D - This is a new one-dimensional hydrodynamic and sediment tr...

  6. 26 CFR 601.106 - Appeals functions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... advice adverse to the taxpayer should be given and a conference has been requested, the taxpayer will be... after payment, but shall be made before the filing of a claim for refund. Technical advice procedures... Office technical advice is furnished concerning exemption or qualification, the decision of the National...

  7. 77 FR 20377 - Biomass Research and Development Technical Advisory Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-04

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Biomass Research and... Biomass Research and Development Technical Advisory Committee under Section 9008(d) of the Food... procedures, members of the public are welcome to observe the business of the Biomass Research and Development...

  8. Fox Valley Technical Institute Economic Development Plan.

    ERIC Educational Resources Information Center

    Fox Valley Technical Inst., Appleton, WI.

    Designed as an operating blueprint for Fox Valley Technical Institute's (FVTI's) economic development efforts, this guide incorporates the necessary operation procedures, descriptions, and resources for those involved in FVTI's effort to assist existing businesses to expand and to attract new businesses to the area. Introductory material describes…

  9. Emerging from Resistance: The Origins of the Virginia Technical College System

    ERIC Educational Resources Information Center

    Hodges, Richard Allen

    2016-01-01

    The purpose of this study was to explore factors leading to the founding of the Virginia Technical College System (VTCS). These factors are observed primarily within the timeframe of 1954-1966. The Virginia Community College System (VCCS) evolved from the Technical College System, and began in 1964. Classes started at the first technical colleges…

  10. Final Rule for Procedures for Testing Highway and Nonroad Engines and Omnibus Technical Amendments

    EPA Pesticide Factsheets

    This common set of test requirements is intended to streamline laboratory efforts for EPA and industry and to form the basis for internationally harmonized test procedures for nearly all categories of engines.

  11. Relationship between Procedural Tactical Knowledge and Specific Motor Skills in Young Soccer Players

    PubMed Central

    Aquino, Rodrigo; Marques, Renato Francisco R.; Petiot, Grégory Hallé; Gonçalves, Luiz Guilherme C.; Moraes, Camila; Santiago, Paulo Roberto P.; Puggina, Enrico Fuini

    2016-01-01

    The purpose of this study was to investigate the association between offensive tactical knowledge and the soccer-specific motor skills performance. Fifteen participants were submitted to two evaluation tests, one to assess their technical and tactical analysis. The motor skills performance was measured through four tests of technical soccer skills: ball control, shooting, passing and dribbling. The tactical performance was based on a tactical assessment system called FUT-SAT (Analyses of Procedural Tactical Knowledge in Soccer). Afterwards, technical and tactical evaluation scores were ranked with and without the use of the cluster method. A positive, weak correlation was perceived in both analyses (rho = 0.39, not significant p = 0.14 (with cluster analysis); and rho = 0.35; not significant p = 0.20 (without cluster analysis)). We can conclude that there was a weak association between the technical and the offensive tactical knowledge. This shows the need to reflect on the use of such tests to assess technical skills in team sports since they do not take into account the variability and unpredictability of game actions and disregard the inherent needs to assess such skill performance in the game. PMID:29910300

  12. Radiation Dose Reduction in CT Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection by Modifying Scout and Planning Steps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paik, Nam Chull, E-mail: pncspine@gmail.com

    Background and PurposeIn CT fluoroscopy (CTF)-guided cervical transforaminal epidural steroid injection (TFESI), the majority of radiation dose is contributed by the planning CT scan rather than the CTF procedure itself. We replaced the planning helical CT with a spot CTF and accordingly changed the patient posture during scout and planning scans. The aim of this study was to test whether radiation dose reduction would be achieved by this protocol modification while still maintaining technical performance.MethodsOverall, 338 consecutive procedures before (control group: n = 163) and after (study group: n = 175) instituting the above-mentioned protocol modification were analyzed retrospectively, comparing patient characteristics (age, sex,more » neck diameter, and level injected) and technical performance [technical success rate, dose-length product (DLP), inadvertent contrast flow incidence, number of CTF acquisitions, and procedural time] between the two groups.ResultsAll injections were technically successful at every level from C3–C4 to C7–T1 without serious complications in both groups. The median DLP of the study group (7.92 mGy·cm) was significantly reduced compared to that of the control group (39.05 mGy·cm, P < 0.001). There were no significant differences between the two groups regarding the incidence of inadvertent contrast flow (20.6 vs. 17.2 %, P = 0.426), number of CTF acquisitions (median 5 vs. 4, P = 0.123), and the procedural time (median 6.62 vs. 6.90 min, P = 0.100).ConclusionsWhen conducting CTF-guided cervical TFESIs, a significant radiation dose reduction (median 79.7 % in DLP) can be achieved by modifying scout and planning steps, without compromising the technical performance.« less

  13. NECAP 4.1: NASA's Energy-Cost Analysis Program fast input manual and example

    NASA Technical Reports Server (NTRS)

    Jensen, R. N.; Miner, D. L.

    1982-01-01

    NASA's Energy-Cost Analysis Program (NECAP) is a powerful computerized method to determine and to minimize building energy consumption. The program calculates hourly heat gain or losses taking into account the building thermal resistance and mass, using hourly weather and a response factor method. Internal temperatures are allowed to vary in accordance with thermostat settings and equipment capacity. NECAP 4.1 has a simplified input procedure and numerous other technical improvements. A very short input method is provided. It is limited to a single zone building. The user must still describe the building's outside geometry and select the type of system to be used.

  14. CSPD Technical Manual: Procedures for Comprehensive Assessment of Educational Personnel Supply/Demand. 1990 Edition.

    ERIC Educational Resources Information Center

    Lauritzen, Paul; Friedman, Stephen

    This manual presents procedures for collecting data to project personnel needs in the field of special education, addressing in part the Comprehensive System of Personnel Development requirements of Public Law 94-142. Implementation of the procedures identifies: areas of education that show need for additional teachers as well as areas of surplus;…

  15. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedures. 53.23 Section 53.23... Methods SO2, CO, O3, and NO2 § 53.23 Test procedures. (a) Range—(1) Technical definition. Nominal minimum... specified at the lower and upper range limits in concentration units, for example, 0-0.5 p/m. (2) Test...

  16. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test procedures. 53.23 Section 53.23... Methods SO2, CO, O3, and NO2 § 53.23 Test procedures. (a) Range—(1) Technical definition. Nominal minimum... specified at the lower and upper range limits in concentration units, for example, 0-0.5 p/m. (2) Test...

  17. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    PubMed

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  18. Automatically inserted technical details improve radiology report accuracy.

    PubMed

    Abujudeh, Hani H; Govindan, Siddharth; Narin, Ozden; Johnson, Jamlik Omari; Thrall, James H; Rosenthal, Daniel I

    2011-09-01

    To assess the effect of automatically inserted technical details on the concordance of a radiology report header with the actual procedure performed. The study was IRB approved and informed consent was waived. We obtained radiology report audit data from the hospital's compliance office from the period of January 2005 through December 2009 spanning a total of 20 financial quarters. A "discordance percentage" was defined as the percentage of total studies in which a procedure code change was made during auditing. Using Chi-square analysis we compared discordance percentages between reports with manually inserted technical details (MITD) and automatically inserted technical details (AITD). The second quarter data of 2007 was not included in the analysis as the switch from MITD to AITD occurred during this quarter. The hospital's compliance office audited 9,110 studies from 2005-2009. Excluding the 564 studies in the second quarter of 2007, we analyzed a total of 8,546 studies, 3,948 with MITD and 4,598 with AITD. The discordance percentage in the MITD group was 3.95% (156/3,948, range per quarter, 1.5- 6.1%). The AITD discordance percentage was 1.37% (63/4,598, range per quarter, 0.0-2.6%). A Chi-square analysis determined a statistically significant difference between the 2 groups (P < 0.001). There was a statistically significant improvement in the concordance of a radiology report header with the performed procedure using automatically inserted technical details compared to manually inserted details. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Remote navigation systems in electrophysiology.

    PubMed

    Schmidt, Boris; Chun, Kyoung Ryul Julian; Tilz, Roland R; Koektuerk, Buelent; Ouyang, Feifan; Kuck, Karl-Heinz

    2008-11-01

    Today, atrial fibrillation (AF) is the dominant indication for catheter ablation in big electrophysiologists (EP) centres. AF ablation strategies are complex and technically challenging. Therefore, it would be desirable that technical innovations pursue the goal to improve catheter stability to increase the procedural success and most importantly to increase safety by helping to avoid serious complications. The most promising technical innovation aiming at the aforementioned goals is remote catheter navigation and ablation. To date, two different systems, the NIOBE magnetic navigation system (MNS, Stereotaxis, USA) and the Sensei robotic navigation system (RNS, Hansen Medical, USA), are commercially available. The following review will introduce the basic principles of the systems, will give an insight into the merits and demerits of remote navigation, and will further focus on the initial clinical experience at our centre with focus on pulmonary vein isolation (PVI) procedures.

  20. Fluoroscopic guide wire manipulation of malfunctioning peritoneal dialysis catheters initially placed by interventional radiologists.

    PubMed

    Kwon, Young Ho; Kwon, Se Hwan; Oh, Joo Hyeong; Jeong, Kyung Hwan; Lee, Tae Won

    2014-06-01

    To assess the efficacy of fluoroscopic guide wire manipulation in patients with malfunctioning peritoneal dialysis (PD) catheters that were initially placed by interventional radiologists under fluoroscopic guidance. From January 2002 to April 2012, 52 patients (mean age, 52.8 y ± 2.10s; range, 12-79 y) with malfunctioning PD catheters in whom fluoroscopic guide wire manipulation was performed were retrospectively reviewed. Technical success, clinical success, and complications were evaluated. Technical success was defined as fluoroscopically verified, successful catheter repositioning and adequate dialysate drainage after the procedure. Clinical success was defined as maintenance of PD catheter function for at least 30 days after the manipulation. During the study period, 72 manipulations (68 initial manipulations and 4 remanipulations) for malfunctioning PD catheters were done. The technical success rate was 74% (50 of 68) for initial manipulations and 75% (3 of 4) for remanipulations. The overall clinical success rate was 47% (32 of 68) for initial manipulations and 0% (0 of 4) for remanipulations. The primary causes of catheter malfunction were extraluminal obstruction by omental wrapping or adhesions in 43 of 68 cases (63.2%) and catheter malposition in 25 of 68 (36.8%) cases. There were no procedure-related major complications. Fluoroscopic guide wire manipulation in patients with malfunctioning PD catheters initially placed by interventional radiologists is a simple procedure, an effective way of prolonging PD catheter life, and a recommended procedure before invasive surgical procedures. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  1. 76 FR 80226 - Technical Amendments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-23

    ... final rule, effective upon publication. Generally, the Administrative Procedure Act (APA) requires a.... Additionally, the APA requires that a final rule must have a delayed effective date of 30 days from the date of... delayed effective date requirement under the APA. 5 U.S.C. 553(d)(3). Again the technical change conforms...

  2. 78 FR 36083 - Small Business Size Standards; Educational Services; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... industries and the Job Corps Centers exception under NAICS 611519, Other Technical and Trade Schools, within.... List of Subjects in 13 CFR Part 121 Administrative practice and procedure, Government procurement... * * * * * * * 611519 Other Technical and Trade Schools. $14.0 Except, Job Corps Centers \\16\\ \\16\\ 35.5...

  3. Student Flow Model SFM-IA: System Documentation. Technical Report 41B. Preliminary Edition.

    ERIC Educational Resources Information Center

    Busby, John C.; Johnson, Richard S.

    Technical specifications, operating procedures, and reference information for the National Center for Higher Education Management Systems' (NCHEMS) Student Flow Model (SFM) computer programs are presented. Included are narrative descriptions of the system and its modules, specific program documentation for each of the modules, system flowcharts,…

  4. Computerising the Salesforce: The Introduction of Technical Change in a Non-Union Workforce.

    ERIC Educational Resources Information Center

    Newell, Helen; Lloyd, Caroline

    1998-01-01

    Results of interviews with 13 pharmaceutical sales representatives, five sales managers, and six human-resource managers and 47 survey responses showed that introduction of information technology was seen as purely technical; human-resources departments played no role; and informal communication procedures enabled management to ignore individual…

  5. 15 CFR Supplement No. 2 to Part 730 - Technical Advisory Committees

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... utilization of production technology; licensing procedures that affect the level of export controls applicable... questions involving technical matters, worldwide availability and actual utilization of production and... of U.S. producers of such items; and (ii) The volume of annual production by such persons or firms of...

  6. 10 CFR 1303.101 - Scope

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Scope 1303.101 Section 1303.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PUBLIC INFORMATION AND REQUESTS § 1303.101 Scope This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding public access to...

  7. 10 CFR 1303.101 - Scope

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Scope 1303.101 Section 1303.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PUBLIC INFORMATION AND REQUESTS § 1303.101 Scope This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding public access to...

  8. 10 CFR 1303.101 - Scope

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Scope 1303.101 Section 1303.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PUBLIC INFORMATION AND REQUESTS § 1303.101 Scope This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding public access to...

  9. 10 CFR 1303.101 - Scope

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Scope 1303.101 Section 1303.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PUBLIC INFORMATION AND REQUESTS § 1303.101 Scope This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding public access to...

  10. 10 CFR 1303.101 - Scope

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Scope 1303.101 Section 1303.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PUBLIC INFORMATION AND REQUESTS § 1303.101 Scope This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding public access to...

  11. Automation and the Workplace. Selected Labor, Education, and Training Issues. A Technical Memorandum.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Office of Technology Assessment.

    This technical memorandum discusses procedures for evaluating potential employment change associated with automation and outlines associated problems. It also describes the nature and modes of delivery of education, training, and retraining for persons holding or seeking employment in manufacturing industries. An introduction provides a brief…

  12. 46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Subpart C of Part 197—Substance Technical Guidelines, Benzene I. Physical and Chemical Data (a) Substance...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... engineering). (b) Reactivity. (1) Conditions contributing to instability: Heat. (2) Incompatibility: Heat and...

  13. Women in Technical Education. Annual Report 1990-91.

    ERIC Educational Resources Information Center

    Texas State Technical Coll., Waco.

    First-year activities of Women in Technical Education, a project to develop a model for women in that field, were evaluated. A formative evaluation showed that intense development and implementation activity enabled achievement of first-year goals and objectives during the 1990-91 year. Procedures to accomplish objectives were effective.…

  14. 78 FR 38949 - Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-28

    ... information as part of the research needed to write a NIST Special Publication (SP) to help Computer Security.... The NIST SP will identify technical standards, methodologies, procedures, and processes that facilitate prompt and effective response. This RFI requests information regarding technical best practices...

  15. 48 CFR 31.205-43 - Trade, business, technical, and professional activity costs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Trade, business, technical, and professional activity costs. 31.205-43 Section 31.205-43 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Contracts With Commercial Organizations...

  16. 48 CFR 31.205-43 - Trade, business, technical, and professional activity costs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Trade, business, technical, and professional activity costs. 31.205-43 Section 31.205-43 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Contracts With Commercial Organizations...

  17. 48 CFR 31.205-43 - Trade, business, technical, and professional activity costs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Trade, business, technical, and professional activity costs. 31.205-43 Section 31.205-43 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Contracts With Commercial Organizations...

  18. 48 CFR 31.205-43 - Trade, business, technical, and professional activity costs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Trade, business, technical, and professional activity costs. 31.205-43 Section 31.205-43 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Contracts With Commercial Organizations...

  19. Design Software Gives Rocketry a Boost in the Classroom

    ERIC Educational Resources Information Center

    Wilson, Spencer C.

    2005-01-01

    Building and launching model rockets makes a great activity for a technology education class. A model rocket curriculum provides a valuable tool for improving students' technical skills, including following technical instructions and procedures while learning about aerospace technology. This article describes a way of making model rocketry more…

  20. Design Software Gives Rocketry a Boost in the Classroom

    ERIC Educational Resources Information Center

    Wilson, Spencer C.

    2005-01-01

    Building and launching model rockets makes a great activity for a technology education class. A model rocket curriculum provides a valuable tool for improving students' technical skills that includes, but is not limited to, following technical instructions and procedures while learning about aerospace technology. This article describes a way that…

  1. 76 FR 58144 - Defense Federal Acquisition Regulation Supplement; Presumption of Development Exclusively at...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    ... technical data package, in cases where the Government may have funded only a small portion of the... subcontractor's asserted restrictions on technical data and computer software. DATES: Effective date: September... data and computer software. More specifically, the final rule affects these validation procedures in...

  2. Problems Relating to Examinations in Three-Year Technical/Natural Science Courses of Study at the Federal Armed Forces University, Munich.

    ERIC Educational Resources Information Center

    Ulbricht, Kurt; Zimmermann, Peter

    1981-01-01

    Problems encountered in testing in aerospace engineering courses in an accelerated technical program of a German military university are outlined. Four common grading procedures are compared, and the optimum length of written tests is discussed. (MSE)

  3. An evaluation of patient attitudes to colonoscopy and the importance of endoscopist interaction and the endoscopy environment to satisfaction and value.

    PubMed

    McEntire, Jude; Sahota, Jagdeep; Hydes, Theresa; Trebble, Timothy Mark

    2013-03-01

    Understanding patients' attitudes to their medical experience is essential for identifying value in the patient pathway, optimizing care and use of resources. This service evaluation was undertaken to determine patients' preferences and expectations for day case colonoscopy, a common gastrointestinal procedure for which there is limited such data. Patients attending for elective colonoscopy were invited to complete a composite, validated dedicated endoscopy questionnaire, with Likert-scale questions and a 15-point preference (ranking) scale of domains of endoscopy care that were considered most important (1) to least important (15) as contributing to a satisfactory experience. Two hundred and sixteen out of 224 patients returned questionnaires. Moderate to severe anxiety was recorded in 56% of patients, commonly with respect to anticipation of pain or the results of the procedure. The median values for ranked preference scores consistent with greatest importance for satisfaction were technical skill of the endoscopist (1), discomfort during the procedure (4), and manner of the endoscopist (5). Factors considered of relatively low importance included the single-sex environment (15) (although this was more important to female patients), noise levels (13), and explanation of delay (11). Only 14% of patients responded that they would be prepared to delay an appointment for a single-sex environment. Patients undergoing colonoscopy highly prioritize aspects of care relating to the interaction with the endoscopist and the procedure itself. Environment factors are considered to be less important. These findings may assist in service redesign around patient-identified value within the patient pathway.

  4. Current status and perspectives in split liver transplantation

    PubMed Central

    Lauterio, Andrea; Di Sandro, Stefano; Concone, Giacomo; De Carlis, Riccardo; Giacomoni, Alessandro; De Carlis, Luciano

    2015-01-01

    Growing experience with the liver splitting technique and favorable results equivalent to those of whole liver transplant have led to wider application of split liver transplantation (SLT) for adult and pediatric recipients in the last decade. Conversely, SLT for two adult recipients remains a challenging surgical procedure and outcomes have yet to improve. Differences in organ shortages together with religious and ethical issues related to cadaveric organ donation have had an impact on the worldwide distribution of SLT. Despite technical refinements and a better understanding of the complex liver anatomy, SLT remains a technically and logistically demanding surgical procedure. This article reviews the surgical and clinical advances in this field of liver transplantation focusing on the role of SLT and the issues that may lead a further expansion of this complex surgical procedure. PMID:26494957

  5. 7 CFR 614.3 - Decisions subject to informal appeal procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Soil and Water Conservation Program; (iv) Water Bank Program; (v) Watershed Protection and Flood... CONSERVATION SERVICE, DEPARTMENT OF AGRICULTURE CONSERVATION OPERATIONS NRCS APPEAL PROCEDURES § 614.3... technical determinations made with respect to: (1) Conservation programs and regulatory requirements...

  6. 7 CFR 614.3 - Decisions subject to informal appeal procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Soil and Water Conservation Program; (iv) Water Bank Program; (v) Watershed Protection and Flood... CONSERVATION SERVICE, DEPARTMENT OF AGRICULTURE CONSERVATION OPERATIONS NRCS APPEAL PROCEDURES § 614.3... technical determinations made with respect to: (1) Conservation programs and regulatory requirements...

  7. Evaluation of contract time estimation and contracting procedures : technical summary.

    DOT National Transportation Integrated Search

    1996-08-01

    The objective of this research was 1) to provide the DOTD with a systematic approach to the determination of contract duration, and 2) to explore innovative contracting procedures that may prove beneficial in DOTD projects. The innovative contracting...

  8. 16 CFR 1616.32 - Method for establishment and use of alternate laundering procedures under section 5(c)(4)(ii) of...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... after Repeated Home Laundering,” Technical Manual of the American Association of Textile Chemists and... containing the same identity while in production. (b) Application procedure. (1) Applicants seeking approval...

  9. 16 CFR 1615.32 - Method for establishment and use of alternate laundering procedures under section 4(g)(4)(ii) of...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... after Repeated Home Laundering,” Technical Manual of the American Association of Textile Chemists and... containing the same identity while in production. (b) Application procedure. (1) Applicants seeking approval...

  10. Partial Red Blood Cell Exchange in Children and Young Patients with Sickle Cell Disease: Manual Versus Automated Procedure.

    PubMed

    Escobar, Carlos; Moniz, Marta; Nunes, Pedro; Abadesso, Clara; Ferreira, Teresa; Barra, António; Lichtner, Anabela; Loureiro, Helena; Dias, Alexandra; Almeida, Helena

    2017-10-31

    The benefits of manual versus automated red blood cell exchange have rarely been documented and studies in young sickle cell disease patients are scarce. We aim to describe and compare our experience in these two procedures. Young patients (≤ 21 years old) who underwent manual- or automated-red blood cell exchange for prevention or treatment of sickle cell disease complications were included. Clinical, technical and hematological data were prospectively recorded and analyzed. Ninety-four red blood cell exchange sessions were performed over a period of 68 months, including 57 manual and 37 automated, 63 for chronic complications prevention, 30 for acute complications and one in the pre-operative setting. Mean decrease in sickle hemoglobin levels was higher in automated-red blood cell exchange (p < 0.001) and permitted a higher sickle hemoglobin level decrease per volume removed (p < 0.001), while hemoglobin and hematocrit remained stable. Ferritin levels on chronic patients decreased 54%. Most frequent concern was catheter outflow obstruction on manual-red blood cell exchange and access alarm on automated-red blood cell exchange. No major complication or alloimunization was recorded. Automated-red blood cell exchange decreased sickle hemoglobin levels more efficiently than manual procedure in the setting of acute and chronic complications of sickle cell disease, with minor technical concerns mainly due to vascular access. The threshold of sickle hemoglobin should be individualized for clinical and hematological goals. In our cohort of young patients, the need for an acceptable venous access was a limiting factor, but iron-overload was avoided. Automated red blood cell exchange is safe and well tolerated. It permits a higher sickle hemoglobin removal efficacy, better volume status control and iron-overload avoidance.

  11. Technical considerations and precautions in in situ bronchoalveolar lavage and alveolar infiltrating cells isolation in rats.

    PubMed

    Qamar, Wajhul

    2015-01-01

    Bronchoalveolar lavage fluid (BALF) is an important tool in experimental toxicology and pharmacology. A number of researchers have utilized BAL in studies involving rodents. However, the detailed procedure of performing BAL in rodents has rarely been reported. In the present article, in situ BAL in rats has been described with technical points that ensure the quality and validity of BALF samples. BAL was performed in rats of Wistar strain. Flow cytometry and microscopy were utilized to analyze the BAL cells. The collected volume of BALF was 84.32 ± 2.7% of instilled volume. Alveolar macrophages were found to be prevalent in normal lungs when analyzed under microscope and by flow cytometry. The main problem that one may face is the accidental contamination of BALF samples with blood of the animal itself. Presence of blood in BALF certainly adds a significant number of cells and other biochemical variables. No blood contamination was detected in BALF. Here, a simple procedure for BAL and collection of alveolar cells (macrophages in the present study) is explained with an emphasis on technical steps and precautions, which ensures the quality of the BALF samples. Data exhibit that there is no blood contamination in the BALF and provide evidence that the technical points considered in the procedure here are successful in maintaining the quality and validity of BALF samples.

  12. Quantification of a Non-conventional Protein Secretion: The Low-Molecular-Weight FGF-2 Example.

    PubMed

    Arcondéguy, Tania; Touriol, Christian; Lacazette, Eric

    2016-01-01

    Quantification of secreted factors is most often measured with enzyme-linked immunosorbent assay (ELISA), Western Blot, or more recently with antibody arrays. However, some of these, like low-molecular-weight fibroblast growth factor-2 (LMW FGF-2; the 18 kDa form), exemplify a set of secreted but almost non-diffusible molecular actors. It has been proposed that phosphorylated FGF-2 is secreted via a non-vesicular mechanism and that heparan sulfate proteoglycans function as extracellular reservoir but also as actors for its secretion. Heparan sulfate is a linear sulfated polysaccharide present on proteoglycans found in the extracellular matrix or anchored in the plasma membrane (syndecan). Moreover the LMW FGF-2 secretion appears to be activated upon FGF-1 treatment. In order to estimate quantification of such factor export across the plasma membrane, technical approaches are presented (evaluation of LMW FGF-2: (1) secretion, (2) extracellular matrix reservoir, and (3) secretion modulation by surrounding factors) and the importance of such procedures in the comprehension of the biology of these growth factors is underlined.

  13. The influence of individual and organisational factors on nurses' behaviour to use lifting devices in healthcare.

    PubMed

    Koppelaar, E; Knibbe, J J; Miedema, H S; Burdorf, A

    2013-07-01

    This study evaluates the influence of individual and organisational factors on nurses' behaviour to use lifting devices in healthcare. Interviews among nurses were conducted to collect individual characteristics and to establish their behaviour regarding lifting devices use. Organisational factors were collected by questionnaires and walk-through-surveys, comprising technical facilities, organisation of care, and management-efforts. Generalised-Estimating-Equations for repeated measurements were used to estimate determinants of nurses' behaviour. Important determinants of nurses' behaviour to use lifting devices were knowledge of workplace procedures (OR = 5.85), strict guidance on required lifting devices use (OR = 2.91), and sufficient lifting devices (OR = 1.92). Management-support and supportive-management-climate were associated with these determinants. Since nurses' behaviour to use lifting devices is influenced by factors at different levels, studies in ergonomics should consider how multi-level factors impact each other. An integral approach, addressing individual and organisational levels, is necessary to facilitate appropriate implementation of ergonomic interventions, like lifting devices. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. Are general surgeons able to accurately self-assess their level of technical skills?

    PubMed

    Rizan, C; Ansell, J; Tilston, T W; Warren, N; Torkington, J

    2015-11-01

    Self-assessment is a way of improving technical capabilities without the need for trainer feedback. It can identify areas for improvement and promote professional medical development. The aim of this review was to identify whether self-assessment is an accurate form of technical skills appraisal in general surgery. The PubMed, MEDLINE(®), Embase(™) and Cochrane databases were searched for studies assessing the reliability of self-assessment of technical skills in general surgery. For each study, we recorded the skills assessed and the evaluation methods used. Common endpoints between studies were compared to provide recommendations based on the levels of evidence. Twelve studies met the inclusion criteria from 22,292 initial papers. There was no level 1 evidence published. All papers compared the correlation between self-appraisal versus an expert score but differed in the technical skills assessment and the evaluation tools used. The accuracy of self-assessment improved with increasing experience (level 2 recommendation), age (level 3 recommendation) and the use of video playback (level 3 recommendation). Accuracy was reduced by stressful learning environments (level 2 recommendation), lack of familiarity with assessment tools (level 3 recommendation) and in advanced surgical procedures (level 3 recommendation). Evidence exists to support the reliability of self-assessment of technical skills in general surgery. Several variables have been shown to affect the accuracy of self-assessment of technical skills. Future work should focus on evaluating the reliability of self-assessment during live operating procedures.

  15. A model to determine payments associated with radiology procedures.

    PubMed

    Mabotuwana, Thusitha; Hall, Christopher S; Thomas, Shiby; Wald, Christoph

    2017-12-01

    Across the United States, there is a growing number of patients in Accountable Care Organizations and under risk contracts with commercial insurance. This is due to proliferation of new value-based payment models and care delivery reform efforts. In this context, the business model of radiology within a hospital or health system context is shifting from a primary profit-center to a cost-center with a goal of cost savings. Radiology departments need to increasingly understand how the transactional nature of the business relates to financial rewards. The main challenge with current reporting systems is that the information is presented only at an aggregated level, and often not broken down further, for instance, by type of exam. As such, the primary objective of this research is to provide better visibility into payments associated with individual radiology procedures in order to better calibrate expense/capital structure of the imaging enterprise to the actual revenue or value-add to the organization it belongs to. We propose a methodology that can be used to determine technical payments at a procedure level. We use a proportion based model to allocate payments to individual radiology procedures based on total charges (which also includes non-radiology related charges). Using a production dataset containing 424,250 radiology exams we calculated the overall average technical charge for Radiology to be $873.08 per procedure and the corresponding average payment to be $326.43 (range: $48.27 for XR and $2750.11 for PET/CT) resulting in an average payment percentage of 37.39% across all exams. We describe how charges associated with a procedure can be used to approximate technical payments at a more granular level with a focus on Radiology. The methodology is generalizable to approximate payment for other services as well. Understanding payments associated with each procedure can be useful during strategic practice planning. Charge-to-total charge ratio can be used to approximate radiology payments at a procedure level. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.

    PubMed

    Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K

    2016-08-01

    To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  17. 76 FR 33999 - Spouse and Surviving Spouse; Technical Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-10

    ... procedure, Aged, Authority delegations, Blind, Buildings, Civil rights, Employment, Equal educational... Administrative practice and procedure, Armed forces, Civil rights, Claims, Colleges and universities, Conflict of...-ASSISTED PROGRAMS OF THE DEPARTMENT OF VETERANS AFFAIRS--EFFECTUATION OF TITLE VI OF THE CIVIL RIGHTS ACT...

  18. Technical Assistance Document for Complying with the Toxicity Characteristics Rule and Implementing the Toxicity Characteristic Leaching Procedure

    EPA Pesticide Factsheets

    The goal of this document is to assist the regulated community to make proper utilization of the Toxicity Characteristic Leaching Procedure (TCLP) to demonstrate compliance with the Toxicity Characteristic (TC) and Land Ban Regulations.

  19. 7 CFR 614.3 - Decisions subject to informal appeal procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Innovation Grants, (E) Ground and Surface Water Conservation Program, (F) Klamath Basin Program, and (G... CONSERVATION SERVICE, DEPARTMENT OF AGRICULTURE CONSERVATION OPERATIONS NRCS APPEAL PROCEDURES § 614.3... technical determinations made with respect to: (1) Conservation programs and regulatory requirements...

  20. 7 CFR 614.3 - Decisions subject to informal appeal procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Innovation Grants, (E) Ground and Surface Water Conservation Program, (F) Klamath Basin Program, and (G... CONSERVATION SERVICE, DEPARTMENT OF AGRICULTURE CONSERVATION OPERATIONS NRCS APPEAL PROCEDURES § 614.3... technical determinations made with respect to: (1) Conservation programs and regulatory requirements...

  1. Quality assurance software inspections at NASA Ames: Metrics for feedback and modification

    NASA Technical Reports Server (NTRS)

    Wenneson, G.

    1985-01-01

    Software inspections are a set of formal technical review procedures held at selected key points during software development in order to find defects in software documents--is described in terms of history, participants, tools, procedures, statistics, and database analysis.

  2. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education

    PubMed Central

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J.A.; Dandorf, Stewart J.; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-01-01

    Introduction Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. Methods This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Results Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). Conclusion The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills. PMID:27330672

  3. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    PubMed

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills.

  4. Learning from technical documents: the role of intermodal referring expressions.

    PubMed

    Dupont, Vincent; Bestgen, Yves

    2006-01-01

    We investigated the impact of two types of intermodal referring expressions on efficiency of instructions for use. User manuals for software or technical devices such as a video recording system frequently combine verbal instructions and illustrations. Much research has shown that the presence of an illustration has a beneficial effect on learning. The present study focuses on a factor that modulates this beneficial effect. The combination of text and an illustration can be effective only if the user integrates the information coming from these two media. This integration depends largely on the intermodal referential expressions, the function of which is to mark explicitly the relations between the text and the illustration. In an experiment (N = 104), we compared the effectiveness of two intermodal referring expressions often used in procedural texts: indexes (numbers introduced in the illustrations and in the instructions to establish cross-references) and icons (visual representations of the components of the device, which are inserted in the verbal instructions). The icons condition led to the most efficient use of the device. This experiment shows that learning from multimedia documents depends on the possibility of effectively connecting the verbal instructions to the illustration. Taking into account the ergonomic properties of the cross-media referring expressions should allow text designers to improve the effectiveness of technical documents.

  5. Seismic microzonation in Latin America and the Caribbean: social, cultural, economic and political aspects

    NASA Astrophysics Data System (ADS)

    Murria, J.

    2009-04-01

    The lack of success, not to say failure, of seismic microzonation projects in the Latin America and Caribbean nations-and for that matter elsewhere in the world-should not be attributed to the lack of technical and scientific expertise of our engineers and scientists as there exists in our continent sufficient knowledge and information about the techniques and procedures that have been successfully used elsewhere in the world in the implementation of seismic microzonation projects. The main constrains to the implementation of seismic microzonation projects in Latin America and the Caribbean are of an economic, social, political, and cultural aspects rather than the purely scientific and engineering aspects. Another very important factor contributing to this lack of success has been the apparent failure of the scientific and technical community to convince decision makers (both official and private) that the sound implementation of seismic microzonation projects are a valid instrument to mitigate the negative effects that earthquakes have on the population, on the physical infrastructure and on the environment. An attempt will be made in this paper to analyze these "non technical" aspects and try to arrive at some conclusions as well as to some possible lines of action for the successful implementation of seismic microzonation projects in the seismic risk prone Latin American and Caribbean nations.

  6. Competency-Based Education in Low Resource Settings: Development of a Novel Surgical Training Program.

    PubMed

    McCullough, Meghan; Campbell, Alex; Siu, Armando; Durnwald, Libby; Kumar, Shubha; Magee, William P; Swanson, Jordan

    2018-03-01

    The unmet burden of surgical disease represents a major global health concern, and a lack of trained providers is a critical component of the inadequacy of surgical care worldwide. Competency-based training has been advanced in high-income countries, improving technical skills and decreasing training time, but it is poorly understood how this model might be applied to low- and middle-income countries. We describe the development of a competency-based program to accelerate specialty training of in-country providers in cleft surgery techniques. The program was designed and piloted among eight trainees at five international cleft lip and palate surgical mission sites in Latin America and Africa. A competency-based evaluation form, designed for the program, was utilized to grade general technical and procedure-specific competencies, and pre- and post-training scores were analyzed using a paired t test. Trainees demonstrated improvement in average procedure-specific competency scores for both lip repairs (60.4-71.0%, p < 0.01) and palate (50.6-66.0%, p < 0.01). General technical competency scores also improved (63.6-72.0%, p < 0.01). Among the procedural competencies assessed, surgical markings showed the greatest improvement (19.0 and 22.8% for lip and palate, respectively), followed by nasal floor/mucosal approximation (15.0%) and hard palate dissection (17.1%). Surgical delivery models in LMICs are varied, and trade-offs often exist between goals of case throughput, quality and training. Pilot program results show that procedure-specific and general technical competencies can be improved over a relatively short time and demonstrate the feasibility of incorporating such a training program into surgical outreach missions.

  7. U.S. Department of Energy Vehicle Technologies Program: Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christophersen, Jon P.

    2014-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of somemore » of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).« less

  8. Interventional Radiology-Operated Cholecystoscopy for the Management of Symptomatic Cholelithiasis: Approach, Technical Success, Safety, and Clinical Outcomes.

    PubMed

    Patel, Nishant; Chick, Jeffrey Forris Beecham; Gemmete, Joseph J; Castle, Jordan C; Dasika, Narasimham; Saad, Wael E; Srinivasa, Ravi N

    2018-05-01

    The objective of our study was to report the technique, complications, and clinical outcomes of interventional radiology-operated cholecystoscopy with stone removal for the management of symptomatic cholelithiasis. Ten (77%) men and three (23%) women (mean age, 65 years) with symptomatic cholelithiasis underwent cholecystostomy followed by interventional radiology-operated cholecystoscopy with stone removal. Major comorbidities precluding cholecystectomy included prior cardiac, pulmonary, or abdominal surgery; cirrhosis; sepsis with hyponatremia; seizure disorder; developmental delay; and cholecystoduodenal fistula. Cholecystostomy access, time between cholecystostomy and cholecystoscopy, endoscopic and fragmentation devices used, technical success, procedure time, fluoroscopy time, complications, length of hospital stay, time between cholecystoscopy and cholecystostomy removal, follow-up, and acute cholecystitis recurrence were recorded. Eleven (85%) patients underwent transhepatic cholecystostomy, and two (15%) patients underwent transperitoneal cholecystostomy. The mean time from cholecystostomy to cholecystoscopy was 151 days. Flexible endoscopy was used in eight (62%) patients, rigid endoscopy in three (23%), and both flexible and rigid in two (15%). Electrohydraulic lithotripsy was used in eight procedures, nitinol baskets in seven, ultrasonic lithotripsy in two, and percutaneous thrombectomy devices in one. Primary technical success was achieved in 11 (85%) patients, and secondary technical success was achieved in 13 (100%) patients. The mean procedure time was 164 minutes, and the mean number of procedures required to clear all gallstones was 1. One (8%) patient developed acute pancreatitis, and one (8%) patient died of gastrointestinal hemorrhage. The median hospital length of stay after cholecystoscopy was 1 day for postoperative monitoring. The mean time between cholecystoscopy and cholecystostomy removal was 39 days. One (8%) patient developed recurrent acute cholecystitis 1095 days after cholecystoscopy. Interventional radiology-operated cholecystoscopy may serve as an effective method for percutaneous gallstone removal in patients with multiple comorbidities precluding cholecystectomy.

  9. Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com; Ierardi, Anna Maria; Radaelli, Alessandro

    AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrastmore » utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.« less

  10. Technical skills assessment toolbox: a review using the unitary framework of validity.

    PubMed

    Ghaderi, Iman; Manji, Farouq; Park, Yoon Soo; Juul, Dorthea; Ott, Michael; Harris, Ilene; Farrell, Timothy M

    2015-02-01

    The purpose of this study was to create a technical skills assessment toolbox for 35 basic and advanced skills/procedures that comprise the American College of Surgeons (ACS)/Association of Program Directors in Surgery (APDS) surgical skills curriculum and to provide a critical appraisal of the included tools, using contemporary framework of validity. Competency-based training has become the predominant model in surgical education and assessment of performance is an essential component. Assessment methods must produce valid results to accurately determine the level of competency. A search was performed, using PubMed and Google Scholar, to identify tools that have been developed for assessment of the targeted technical skills. A total of 23 assessment tools for the 35 ACS/APDS skills modules were identified. Some tools, such as Operative Performance Rating System (OSATS) and Objective Structured Assessment of Technical Skill (OPRS), have been tested for more than 1 procedure. Therefore, 30 modules had at least 1 assessment tool, with some common surgical procedures being addressed by several tools. Five modules had none. Only 3 studies used Messick's framework to design their validity studies. The remaining studies used an outdated framework on the basis of "types of validity." When analyzed using the contemporary framework, few of these studies demonstrated validity for content, internal structure, and relationship to other variables. This study provides an assessment toolbox for common surgical skills/procedures. Our review shows that few authors have used the contemporary unitary concept of validity for development of their assessment tools. As we progress toward competency-based training, future studies should provide evidence for various sources of validity using the contemporary framework.

  11. Cross-national research on contractor evaluation procedures in public works procurement

    NASA Astrophysics Data System (ADS)

    Kinoshita, Seiya; Sato, Naoyoshi; Matsumoto, Naoya

    Contractor evaluation methods in Japan's public works procurement, beginning with construction business licensure, going through biennial preliminary firm rating, up to project-by-project prequalification and comprehensive point rating, were developed during the period when public works were mostly procured through designated competitive bidding. It is essential to focus attention on contractor evaluation methods for introducing different types of procurement procedures which enhance the use of technological capabilities held by private businesses. An overall review of contractor evaluation procedures should be conducted in view of the present situation, where the open competitive bidding has become mainly used in combination with comprehensive evaluation, as well as to allow for further diversification of procurement methods. In Western countries, improvements have been made for the past several years in contractor evaluation procedures with more emphasis on "Value for Money." Advanced efforts made by these countries will be useful as a reference for overhauling Japan's contractor evaluation system. This study conducts a comparative review of contractor evaluation procedures for public procurement in Western countries such as the United States, the United Kingdom and France by identifying similarities and differences between those of Japan and the above mentioned countries. This reveals that a contractor's technical or professional ability is looked at separately from its economic and financial standing in those countries studied, and there is no case like Japan in which those two factors are integrated into one for evaluation.

  12. Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, D.R. Jr.; Wondrow, M.A.; Gray, J.E.

    1990-01-01

    The increased application of therapeutic interventional cardiology procedures is associated with increased radiation exposure to physicians, patients and technical personnel. New advances in imaging techniques have the potential for reducing radiation exposure. A progressive scanning video system with a standard vascular phantom has been shown to decrease entrance radiation exposure. The effect of this system on reducing actual radiation exposure to physicians and technicians was assessed from 1984 through 1987. During this time, progressive fluoroscopy was added sequentially to all four adult catheterization laboratories; no changes in shielding procedures were made. During this time, the case load per physician increasedmore » by 63% and the number of percutaneous transluminal coronary angioplasty procedures (a high radiation procedure) increased by 244%. Despite these increases in both case load and higher radiation procedures, the average radiation exposure per physician declined by 37%. During the same time, the radiation exposure for technicians decreased by 35%. Pulsed progressive fluoroscopy is effective for reducing radiation exposure to catheterization laboratory physicians and technical staff.« less

  13. Characterization of technical surfaces by structure function analysis

    NASA Astrophysics Data System (ADS)

    Kalms, Michael; Kreis, Thomas; Bergmann, Ralf B.

    2018-03-01

    The structure function is a tool for characterizing technical surfaces that exhibits a number of advantages over Fourierbased analysis methods. So it is optimally suited for analyzing the height distributions of surfaces measured by full-field non-contacting methods. The structure function is thus a useful method to extract global or local criteria like e. g. periodicities, waviness, lay, or roughness to analyze and evaluate technical surfaces. After the definition of line- and area-structure function and offering effective procedures for their calculation this paper presents examples using simulated and measured data of technical surfaces including aircraft parts.

  14. Lightning Protection Guidelines for Aerospace Vehicles

    NASA Technical Reports Server (NTRS)

    Goodloe, C. C.

    1999-01-01

    This technical memorandum provides lightning protection engineering guidelines and technical procedures used by the George C. Marshall Space Flight Center (MSFC) Electromagnetics and Aerospace Environments Branch for aerospace vehicles. The overviews illustrate the technical support available to project managers, chief engineers, and design engineers to ensure that aerospace vehicles managed by MSFC are adequately protected from direct and indirect effects of lightning. Generic descriptions of the lightning environment and vehicle protection technical processes are presented. More specific aerospace vehicle requirements for lightning protection design, performance, and interface characteristics are available upon request to the MSFC Electromagnetics and Aerospace Environments Branch, mail code EL23.

  15. Task-Based EFL Language Teaching with Procedural Information Design in a Technical Writing Context

    ERIC Educational Resources Information Center

    Roy, Debopriyo

    2017-01-01

    Task-based language learning (TBLL) has heavily influenced syllabus design, classroom teaching, and learner assessment in a foreign or second language teaching context. In this English as foreign language (EFL) learning environment, the paper discussed an innovative language learning pedagogy based on design education and technical writing. In…

  16. Mechanisation and Automation of Information Library Procedures in the USSR.

    ERIC Educational Resources Information Center

    Batenko, A. I.

    Scientific and technical libraries represent a fundamental link in a complex information storage and retrieval system. The handling of a large volume of scientific and technical data and provision of information library services requires the utilization of computing facilities and automation equipment, and was started in the Soviet Union on a…

  17. 77 FR 1129 - Revisions to Test Methods and Testing Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-09

    ...This action proposes editorial and technical corrections necessary for source testing of emissions and operations. The revisions include the addition of alternative equipment and methods as well as corrections to technical and typographical errors. We also solicit public comment on potential changes to the current procedures for determining emission stratification.

  18. Use of "t"-Test and ANOVA in Career-Technical Education Research

    ERIC Educational Resources Information Center

    Rojewski, Jay W.; Lee, In Heok; Gemici, Sinan

    2012-01-01

    Use of t-tests and analysis of variance (ANOVA) procedures in published research from three scholarly journals in career and technical education (CTE) during a recent 5-year period was examined. Information on post hoc analyses, reporting of effect size, alpha adjustments to account for multiple tests, power, and examination of assumptions…

  19. 10 CFR 1304.101 - Purpose and scope.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Purpose and scope. 1304.101 Section 1304.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.101 Purpose and scope. This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding...

  20. 10 CFR 1304.101 - Purpose and scope.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Purpose and scope. 1304.101 Section 1304.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.101 Purpose and scope. This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding...

  1. 10 CFR 1304.101 - Purpose and scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Purpose and scope. 1304.101 Section 1304.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.101 Purpose and scope. This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding...

  2. 10 CFR 1304.101 - Purpose and scope.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Purpose and scope. 1304.101 Section 1304.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.101 Purpose and scope. This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding...

  3. 10 CFR 1304.101 - Purpose and scope.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Purpose and scope. 1304.101 Section 1304.101 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.101 Purpose and scope. This part sets forth the policies and procedures of the U.S. Nuclear Waste Technical Review Board (Board) regarding...

  4. Statewide Curriculum Articulation Project for Vocational-Technical Education in Minnesota. Final Report.

    ERIC Educational Resources Information Center

    Burger, Laura J.; And Others

    The goal of this project was to develop, validate, and utilize a process for vertically articulating curriculum between secondary and post secondary levels of vocational technical education throughout the state of Minnesota. Procedures involved the identification of two areas of staff responsibility: research and development, and service to local…

  5. IDEA Technical Report No. 2. Description of Data Base, 1976-77.

    ERIC Educational Resources Information Center

    Cashin, William E.; Slawson, Hugh M.

    The data and computational procedures used by the IDEA system at Kansas State University (during the 1976-77 academic year) to interpret ratings of teacher performance are described in this technical report. The computations for each of the seven parts (evaluation, course description, students' self ratings, methods, additional questions,…

  6. IDEA Technical Report No. 3. Description of Data Base, 1977-78.

    ERIC Educational Resources Information Center

    Cashin, William E.; Slawson, Hugh M.

    The data and computational procedures used by the IDEA System during the 1977-78 academic year at Kansas State University to interpret ratings of teacher performance are described in this technical report. The computations for each of the seven parts (evaluation, course description, students' self-ratings, methods, additional questions, diagnostic…

  7. Organizing, Concerns and Control Numbers.

    ERIC Educational Resources Information Center

    Washington, Gene

    A heuristic procedure can be used to teach organizational skills to students of technical writing. Designed to allow students on their own to explore ways that numbers can be used to give a definite shape to technical information, its central feature is a matrix composed of a series of control numbers (horizontal axis) and organizing concerns…

  8. Factors that Influence Women's Technical Skill Development in Outdoor Adventure

    ERIC Educational Resources Information Center

    Warren, Karen; Loeffler, TA

    2006-01-01

    This article provides a theoretical foundation for understanding women's technical skill development (TSD) in outdoor adventure. An examination of societal and biological factors influencing women's TSD focuses on gender role socialization, sense of competence, technical conditioning, sexism, spatial ability, and risk-taking. The article suggests…

  9. A Systematic Review of Autologous Platelet-Rich Plasma and Fat Graft Preparation Methods.

    PubMed

    Luck, Joshua; Smith, Oliver J; Mosahebi, Afshin

    2017-12-01

    The addition of platelet-rich plasma (PRP) to adipose tissue may improve fat graft survival, although graft retention rates vary markedly between studies. To what extent this outcome heterogeneity reflects differing methodological factors remains unknown. This systematic review aims to synthesize and critically review methodological approaches to autologous PRP and fat cotransplantation in both human and animal studies. In accordance with PRISMA guidelines, Ovid MEDLINE, Scopus, and Cochrane Library databases were searched from inception to April 2017. Data were extracted from all in vivo studies involving autologous PRP and fat cotransplantation. A secondary aim was to assess reporting of technical detail; authors were not contacted to provide missing data. From 335 articles, 23 studies were included in the qualitative synthesis. Some 21 were performed in humans and 2 in rabbits. Six studies were randomized control trials; the remainder reported on observational data. Methods of PRP extraction and activation varied markedly between studies. Fat graft preparation was comparatively more consistent. Methods of PRP and fat mixing differed significantly, especially with regards to relative volume/volume ratios. Our study represents the first systematic review of methodological factors in autologous PRP and fat cotransplantation. It demonstrates that technical factors in graft preparation and administration vary significantly between in vivo studies. Such methodological heterogeneity may explain observed differences in experimental and clinical outcomes. Reporting of key procedural information is inconsistent and often inadequate. These issues make meaningful evaluation of the PRP-enhanced fat grafting literature difficult and may limit its translation into clinical practice.

  10. Technosocial Modeling of IED Threat Scenarios and Attacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitney, Paul D.; Brothers, Alan J.; Coles, Garill A.

    2009-03-23

    This paper describes an approach for integrating sociological and technical models to develop more complete threat assessment. Current approaches to analyzing and addressing threats tend to focus on the technical factors. This paper addresses development of predictive models that encompass behavioral as well as these technical factors. Using improvised explosive device (IED) attacks as motivation, this model supports identification of intervention activities 'left of boom' as well as prioritizing attack modalities. We show how Bayes nets integrate social factors associated with IED attacks into general threat model containing technical and organizational steps from planning through obtaining the IED to initiationmore » of the attack. The social models are computationally-based representations of relevant social science literature that describes human decision making and physical factors. When combined with technical models, the resulting model provides improved knowledge integration into threat assessment for monitoring. This paper discusses the construction of IED threat scenarios, integration of diverse factors into an analytical framework for threat assessment, indicator identification for future threats, and future research directions.« less

  11. Laparoscopic Ultrasound-Guided Radiofrequency Ablation of Uterine Fibroids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milic, Andrea; Asch, Murray R.; Hawrylyshyn, Peter A.

    Four patients with symptomatic uterine fibroids measuring less than 6 cm underwent laparoscopic ultrasound-guided radiofrequency ablation (RFA) using multiprobe-array electrodes. Follow-up of the treated fibroids was performed with gadolinium-enhanced magnetic resonance imaging (MRI) and patients' symptoms were assessed by telephone interviews. The procedure was initially technically successful in 3 of the 4 patients and MRI studies at 1 month demonstrated complete fibroid ablation. Symptom improvement, including a decrease in menstrual bleeding and pain, was achieved in 2 patients at 3 months. At 7 months, 1 of these 2 patients experienced symptom worsening which correlated with recurrent fibroid on MRI. Themore » third, initially technically successfully treated patient did not experience any symptom relief after the procedure and was ultimately diagnosed with adenomyosis. Our preliminary results suggest that RFA is a technically feasible treatment for symptomatic uterine fibroids in appropriately selected patients.« less

  12. A comparison of transjugular and plugged-percutaneous liver biopsy in patients with contraindications to ordinary percutaneous liver biopsy and an "in-house" protocol for selecting the procedure of choice.

    PubMed

    Atar, Eli; Ben Ari, Ziv; Bachar, Gil N; Amlinski, Yelena; Neyman, Chaim; Knizhnik, Michael; Litvin, Sergey; Schmilovitz-Weiss, Hemda; Shapiro, Riki; Bruckhaimer, Elchanan; Tur-Kaspa, Ran; Belenky, Alexander

    2010-06-01

    The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

  13. [Impact of 3 years of contract implementation on the quality of cataract surgery].

    PubMed

    Begiristain, J; Elizalde, B; Ibarluzea, J; Mendicute, J; Sola, C

    1999-01-01

    To assess the adequacy to clinical practice of cataract procedures contracted in the Gipuzkoa Health Area (in public as well as concerted hospitals) from 1995. A second aim is to identify the achievements obtained three years after its implementation comparing the data with those of 1994, a year before. Before its implementation a multidisciplinar team established the number of surgical procedures to be contracted each year by age and sex, as well as the technical and quality conditions (out-patient surgery, loco-regional anaesthetic, facoemulsification, etc.). Data used for the assessment: Cataracts Registry of the Ophthalmologic Unit, Patient Management Categories and surgical waiting lists. During the period studied, 8,073 cataract operations were performed, 9% higher than expected. The distribution by age and sex was as estimated. Technical and quality standards were fulfilled, except for the surgical waiting list, in at least 75% of the procedures. The surgical technique mainly used was facoenmulsification, increasing from 15% in 1994 to 76.5% in 1997. The contracting of cataract surgery has allowed the assessment, reordering, and establishment of standards of care for all the professionals involved in the process. There were improvements in clinical practice during the period studied. This has given raise to the homogenisation of care in all the units following technical and quality standards, meaning better equity for the patients in need of the procedure.

  14. Retrograde Transpedal Access for Revascularization of Below-the-Knee Arteries in Patients with Critical Limb Ischemia after an Unsuccessful Antegrade Transfemoral Approach.

    PubMed

    Goltz, J P; Planert, M; Horn, M; Wiedner, M; Kleemann, M; Barkhausen, J; Stahlberg, E

    2016-10-01

    To evaluate the safety and technical and clinical success of endovascular below-the-knee (BTK) artery revascularization by a retrograde transpedal access. We retrospectively identified 16/172 patients (9.3 %) with endovascular BTK revascularization in whom a transfemoral approach had failed and transpedal access had been attempted. The dorsal pedal (n = 13) or posterior tibial (n = 3) artery was accessed using a dedicated access set and ultrasound guidance. The procedure was finished in antegrade fashion by plain old balloon angioplasty (POBA). Comorbidities, vessel diameter and calcification at the access site were recorded. The analyzed outcomes were technical success, procedural complications, procedure time, crossing (guidewire beyond lesion and intra-luminal) and procedural (residual stenosis < 30 % after POBA) success, and limb salvage. Diabetes, coronary artery disease and hypertension were present in 15 patients (93.8 %), and both renal impairment and previous amputations in 7 (43.8 %). Pedal access vessel calcification was present in 5/16 patients (31.3 %). The mean diameter was 1.75 +/-0.24 mm. The procedure time was 92.4 +/-23 min. The success rate for achieving retrograde access was 100 %. Retrograde crossing was successful in 12/16 patients (75.0 %). Procedural success was observed in 10/16 patients (68.8 %). Minor complications occurred in 2/16 patients (12.5 %). The rate of limb salvage was 72.9 %, and the overall survival was 100 % at 12 months. Major amputations after revascularization occurred in 2/16 patients (12.5 %). If an antegrade transfemoral approach to BTK lesions fails, a retrograde transpedal approach may nevertheless facilitate treatment. This approach appears to be safe and offers high technical and acceptable clinical success rates. • Retrograde approaches via transpedal or transtibial vessels are safe and offer high technical success.• One problem after technically successful puncture might be the re-entry following subintimal retrograde lesion crossing.• After a failed attempt at antegrade revascularization of a BTK occlusion, a retrograde approach should be performed. Citation Format: • Goltz JP, Planert M, Horn M et al. Retrograde Transpedal Access for Revascularization of Below-the-Knee Arteries in Patients with Critical Limb Ischemia after an Unsuccessful Antegrade Transfemoral Approach. Fortschr Röntgenstr 2016; 188: 940 - 948. © Georg Thieme Verlag KG Stuttgart · New York.

  15. 47 CFR 2.915 - Grant of application.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... RULES AND REGULATIONS Equipment Authorization Procedures Application Procedures for Equipment... officially notice, that: (1) The equipment is capable of complying with pertinent technical standards of the rule part(s) under which it is to be operated; and, (2) A grant of the application would serve the...

  16. 47 CFR 2.915 - Grant of application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... RULES AND REGULATIONS Equipment Authorization Procedures Application Procedures for Equipment... officially notice, that: (1) The equipment is capable of complying with pertinent technical standards of the rule part(s) under which it is to be operated; and, (2) A grant of the application would serve the...

  17. 44 CFR 67.8 - Appeal procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technical or scientific data submitted by the community that tend to negate or contradict the information... FLOOD ELEVATION DETERMINATIONS § 67.8 Appeal procedure. (a) If a community appeals the proposed flood... to an independent scientific body or appropriate Federal agency for advice. (c) The final...

  18. 44 CFR 67.8 - Appeal procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... technical or scientific data submitted by the community that tend to negate or contradict the information... FLOOD ELEVATION DETERMINATIONS § 67.8 Appeal procedure. (a) If a community appeals the proposed flood... to an independent scientific body or appropriate Federal agency for advice. (c) The final...

  19. 77 FR 53889 - Statement of Organization, Functions, and Delegations of Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ..., methods, and statistical procedures for assessing and monitoring the health of communities and measuring... methods and the Community Guide, and coordinates division responses to requests for technical assistance...-federal partners in developing indicators, methods, and statistical procedures for measuring and reporting...

  20. 77 FR 71208 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-29

    ... Government Entities) of the Internal Revenue Service to give advice on filing letter ruling, determination... be registered and the purchaser must give the seller a resale certificate. Affected Public: Private... collection. Title: Revenue Procedure 2011-4 (Letter Rulings), Revenue Procedure 2011-5 (Technical Advice...

  1. 48 CFR 342.7101-2 - Procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Procedures. 342.7101-2 Section 342.7101-2 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES CONTRACT MANAGEMENT... data received; (2) Request audit or cost advisory services, and technical support, as necessary, for...

  2. Combining principles of Cognitive Load Theory and diagnostic error analysis for designing job aids: Effects on motivation and diagnostic performance in a process control task.

    PubMed

    Kluge, Annette; Grauel, Britta; Burkolter, Dina

    2013-03-01

    Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. (Dry) arthroscopic partial wrist arthrodesis: tips and tricks.

    PubMed

    del Piñal, F; Tandioy-Delgado, F

    2014-10-01

    One of the options for performing a partial wrist arthrodesis is the arthroscopic technique. As a first advantage arthroscopy allows us to directly assess the state of the articular surface of the carpal bones and define the best surgical option during the salvage operation. Furthermore, it allows performance of the procedure with minimal ligament damage and minimal interference with the blood supply of the carpals. These will (presumably) entail less capsular scarring and more rapid healing. Lastly, there is cosmetic benefit by reducing the amount of external scarring. The procedure has a steep learning curve even for accomplished arthroscopists but can be performed in a competitive manner to the open procedure if the dry technique is used. The aim of this paper is to present the technical details, tricks and tips to make the procedure accessible to all hand specialists with an arthroscopic interest. As it is paramount that the surgeon is acquainted with the "dry" technique, some technical details about it will also be presented. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis.

    PubMed

    Bagla, Sandeep; Smirniotopoulos, John; Orlando, Julie C; Piechowiak, Rachel

    2017-03-01

    Prostatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH. IRB-approved retrospective study of 40 consecutive patients 49-81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months. No significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm 2 vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred. Robotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  5. Percutaneous Cryoablation of Clinical T2 (> 7 cm) Renal Masses: Technical Considerations, Complications, and Short-Term Outcomes.

    PubMed

    Moynagh, Michael R; Schmit, Grant D; Thompson, Robert H; Boorjian, Stephen A; Woodrum, David A; Curry, Timothy B; Atwell, Thomas D

    2015-06-01

    To determine the technical success, safety, and preliminary clinical outcome of percutaneous cryoablation of large (> 7 cm) renal masses. Twelve patients underwent percutaneous cryoablation for treatment of renal tumors measuring greater than 7 cm (clinical stage II, T2aN0M0) between 2004 and 2013. Median patient age was 75 years (range, 46-84 y), median Charlson comorbidity index was 5 (range, 4-9), and median maximal tumor diameter was 8.4 cm (range, 7.2-9.7 cm). Seven of the 12 patients underwent superselective intraarterial tumor embolization before cryoablation. Technical success, procedural complications, renal function, and oncologic and survival outcomes were evaluated for each patient. All cryoablation procedures were technically successful in a single treatment session, with no mortalities at 30 days. Two patients (17%) experienced major complications related to postprocedural hemorrhage. Median change in estimated glomerular filtration rate within 7 days following cryoablation treatment was 11 mL/min (range, 7-14 mL/min). One patient with baseline stage IV chronic kidney disease and a major bleeding complication required temporary dialysis in the periprocedural period. In 11 patients (92%) who had follow-up beyond 3 months after the procedure (mean, 19 mo; range, 4-49 mo), recurrence-free survival and overall survival rates at 2 years were 100% and 91%, respectively. Percutaneous cryoablation of large (> 7 cm) renal masses was technically successful, with effective preliminary clinical outcomes. However, major complications are more common with cryoablation of stage T2 tumors than is typically encountered with treatment of smaller stage T1 tumors. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  6. Transition to Office-based Obstetric and Gynecologic Procedures: Safety, Technical, and Financial Considerations.

    PubMed

    Peacock, Lisa M; Thomassee, May E; Williams, Valerie L; Young, Amy E

    2015-06-01

    Office-based surgery is increasingly desired by patients and providers due to ease of access, overall efficiency, reimbursement, and satisfaction. The adoption of office-based surgery requires careful consideration of safety, efficacy, cost, and feasibility within a providers practice. This article reviews the currently available data regarding patient and provider satisfaction as well as practical considerations of staffing, equipment, and supplies. To aid the practitioner, issues of office-based anesthesia and safety with references to currently available national guidelines and protocols are provided. Included is a brief review of billing, coding, and reimbursement. Technical procedural aspects with information and recommendations are summarized.

  7. Results of the first provisional technical secretariat interlaboratory comparison test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuff, J.R.; Hoffland, L.

    1995-06-01

    The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.

  8. [Radical prostatectomy - pro robotic].

    PubMed

    Gillitzer, R

    2012-05-01

    Anatomical radical prostatectomy was introduced in the early 1980s by Walsh and Donker. Elucidation of key anatomical structures led to a significant reduction in the morbidity of this procedure. The strive to achieve similar oncological and functional results to this gold standard open procedure but with further reduction of morbidity through a minimally invasive access led to the establishment of laparoscopic prostatectomy. However, this procedure is complex and difficult and is associated with a long learning curve. The technical advantages of robotically assisted surgery coupled with the intuitive handling of the device led to increased precision and shortening of the learning curve. These main advantages, together with a massive internet presence and aggressive marketing, have resulted in a rapid dissemination of robotic radical prostatectomy and an increasing patient demand. However, superiority of robotic radical prostatectomy in comparison to the other surgical therapeutic options has not yet been proven on a scientific basis. Currently robotic-assisted surgery is an established technique and future technical improvements will certainly further define its role in urological surgery. In the end this technical innovation will have to be balanced against the very high purchase and running costs, which remain the main limitation of this technology.

  9. Improved technical success and radiation safety of adrenal vein sampling using rapid, semi-quantitative point-of-care cortisol measurement.

    PubMed

    Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D

    2018-01-01

    Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.

  10. Modular Engine Noise Component Prediction System (MCP) Technical Description and Assessment Document

    NASA Technical Reports Server (NTRS)

    Herkes, William H.; Reed, David H.

    2005-01-01

    This report describes an empirical prediction procedure for turbofan engine noise. The procedure generates predicted noise levels for several noise components, including inlet- and aft-radiated fan noise, and jet-mixing noise. This report discusses the noise source mechanisms, the development of the prediction procedures, and the assessment of the accuracy of these predictions. Finally, some recommendations for future work are presented.

  11. FID Statutes, Rules of Procedures, Terms of Reference.

    ERIC Educational Resources Information Center

    International Federation for Documentation, The Hague (Netherlands).

    Following a brief historical chronology of the International Federation for Documentation (FID), the organization's statutes are presented in the original French text and in English. The rules of procedures outline membership policy, conduct of technical bodies, FID conferences, publications, and regional commissions. Terms of reference are…

  12. An outcomes analysis of patients undergoing body contouring surgery after massive weight loss.

    PubMed

    Shermak, Michele A; Chang, David; Magnuson, Thomas H; Schweitzer, Michael A

    2006-09-15

    Although published reports about technical management of massive weight loss patients are beginning to appear, risk factors for complications following body contouring operations are not known. A retrospective analysis of massive weight loss patients who had body contouring operations between March of 1998 and October of 2004 was performed. Demographic and surgical factors were analyzed. Outcome measures included seroma, wound dehiscence, thromboembolic complications, blood transfusion after surgery, and extended lengths of stay (>2 days). A total of 139 patients were analyzed; 82.7 percent of them were female; mean age was 41 years. On multiple logistic regression, male gender was associated with significant risks for wound dehiscence (odds ratio, 6.4; p = 0.01). There were also trends toward increased risk for wound dehiscence with hypothyroidism (odds ratio, 4.3; p = 0.06) and Ehlers-Danlos syndrome (odds ratio, 18.7; p = 0.05). In terms of risk of blood transfusion, asthma and having three or more procedures were the two variables that emerged with significant association (odds ratio, 16.8 and 13.7, respectively; both p < 0.01). Increased length of stay to greater than 2 days was also significantly associated with having three or more procedures (odds ratio, 4.72; p < 0.01). Male gender, hypothyroidism, and Ehlers-Danlos syndrome may be risk factors for wound dehiscence following body contour operations for massive weight loss. Asthma may be a marker of poor general health status, and asthmatic patients are at increased risk for requiring blood transfusions. Having three or more procedures is associated with an increased risk of blood transfusion and increased length of stay.

  13. Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids: Effect of Bowel Interposition on Procedure Feasibility and a Unique Bowel Displacement Technique.

    PubMed

    Kim, Young-Sun; Lim, Hyo Keun; Rhim, Hyunchul

    2016-01-01

    To evaluate the effect of bowel interposition on assessing procedure feasibility, and the usefulness and limiting conditions of bowel displacement techniques in magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. Institutional review board approved this study. A total of 375 screening MR exams and 206 MR-HIFU ablations for symptomatic uterine fibroids performed between August 2010 and March 2015 were retrospectively analyzed. The effect of bowel interposition on procedure feasibility was assessed by comparing pass rates in periods before and after adopting a unique bowel displacement technique (bladder filling, rectal filling and subsequent bladder emptying; BRB maneuver). Risk factors for BRB failure were evaluated using logistic regression analysis. Overall pass rates of pre- and post-BRB periods were 59.0% (98/166) and 71.7% (150/209), and in bowel-interposed cases they were 14.6% (7/48) and 76.4% (55/72), respectively. BRB maneuver was technically successful in 81.7% (49/60). Through-the-bladder sonication was effective in eight of eleven BRB failure cases, thus MR-HIFU could be initiated in 95.0% (57/60). A small uterus on treatment day was the only significant risk factor for BRB failure (B = 0.111, P = 0.017). The BRB maneuver greatly reduces the fraction of patients deemed ineligible for MR-HIFU ablation of uterine fibroids due to interposed bowels, although care is needed when the uterus is small.

  14. NOTES: a review of the technical problems encountered and their solutions.

    PubMed

    Mintz, Yoav; Horgan, Santiago; Cullen, John; Stuart, David; Falor, Eric; Talamini, Mark A

    2008-08-01

    Natural orifice translumenal endoscopic surgery (NOTES) is currently investigated and developed worldwide. In the past few years, multiple groups have confronted this challenge. Many technical problems are encountered in this technique due to the currently available tools for this approach. Some of the unique technical problems in NOTES include: blindly performed primary incisions; uncontrolled pneumoperitoneal pressure; no support for the endoscope in the abdominal cavity; inadequate vision; insufficient illumination; limited retraction and exposure; and the complexity of suturing and performing a safe anastomosis. In this paper, we review the problems encountered in NOTES and provide possible temporary solutions. Acute and survival studies were performed on 15 farm pigs. The hybrid technique approach (i.e., endoscopic surgery with the aid of laparoscopic vision) was performed in all cases. Procedures performed included liver biopsies, bilateral tubal ligation, oophprectomy, cholecystectomy, splenectomy and small bowel resection, and anastomosis. All attempted procedures were successfully performed. New methods and techniques were developed to overcome the technical problems. Closure of the gastrotomy was achieved by T-bar sutures and by stapler closure of the stomach incision. Small bowel anastomosis was achieved by the dual-lumen NOTES technique. The hybrid technique serves as a temporary approach to aid in developing the NOTES technique. A rectal or vaginal port of entry enables and facilitates gastrointestinal NOTES by using available laparoscopic instruments. The common operations performed today in the laparoscopic fashion could be probably performed in the NOTES approach. The safety of these procedures, however, is yet to be determined.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, Kengo, E-mail: yesterday.is.yesterday@gmail.com; Shimohira, Masashi, E-mail: mshimohira@gmail.com; Sasaki, Shigeru, E-mail: ssasaki916@yahoo.co.jp

    PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success ratesmore » of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors.« less

  16. Balloon dilation of the eustachian tube in a cadaver model: technical considerations, learning curve, and potential barriers.

    PubMed

    McCoul, Edward D; Singh, Ameet; Anand, Vijay K; Tabaee, Abtin

    2012-04-01

    The surgical management options for eustachian tube dysfunction have historically been limited. The goal of the current study was to evaluate the technical considerations, learning curve, and potential barriers for balloon dilation of the eustachian tube (BDET) as an alternative treatment modality. Prospective preclinical trial of BDET in a cadaver model. A novel balloon catheter device was used for eustachian tube dilation. Twenty-four BDET procedures were performed by three independent rhinologists with no prior experience with the procedure (eight procedures per surgeon). The duration and number of attempts of the individual steps and overall procedure were recorded. Endoscopic examination of the eustachian tube was performed after each procedure, and the surgeon was asked to rate the subjective difficulty on a five-point scale. Successful completion of the procedure occurred in each case. The overall mean duration of the procedure was 284 seconds, and a mean number of 1.15 attempts were necessary to perform the individual steps. The mean subjective procedure difficulty was noted as somewhat easy. Statistically shorter duration and subjectively easier procedure were noted in the second compared to the first half of the series, indicating a favorable learning curve. Linear fissuring within the eustachian tube lumen without submucosal disruption (nine procedures, 37%) and with submucosal disruption (five procedures, 21%) were noted. The significance of these physical findings is unclear. Preclinical testing of BDET is associated with favorable duration, learning curve, and overall ease of completion. Clinical trials are necessary to evaluate safety and efficacy. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  17. CIVIL TECHNOLOGY, HIGHWAY AND STRUCTURAL OPTIONS, A SUGGESTED 2-YEAR POST HIGH SCHOOL CURRICULUM. TECHNICAL EDUCATION PROGRAM SERIES, NUMBER 8.

    ERIC Educational Resources Information Center

    BEAUMONT, JOHN A; AND OTHERS

    DESIGNED TO ASSIST ADMINISTRATORS, SUPERVISORS, AND TEACHERS TO PLAN, DEVELOP, AND EVALUATE PROGRAMS, THIS CURRICULUM GUIDE OFFERS COURSE OUTLINES, PROCEDURES, LABORATORY LAYOUTS, TEXTS AND REFERENCES, LISTS OF LABORATORY EQUIPMENT AND ITS COST, AND A SELECTED LIST OF SCIENTIFIC AND TECHNICAL SOCIETIES. BASIC MATERIALS WERE PREPARED AT THE…

  18. Meta-Analysis as a Choice to Improve Research in Career and Technical Education

    ERIC Educational Resources Information Center

    Gordon, Howard R. D.; McClain, Clifford R.; Kim, Yeonsoo; Maldonado, Cecilia

    2010-01-01

    A search of the ERIC and Academic Search Premier data bases, and a comprehensive review of literature suggest that meta-analysis is ignored by career and technical education (CTE) researchers, a situation that is regrettable but remediable. The purpose of this theoretical paper is to provide CTE researchers and consumers with procedures for…

  19. An Assessment of Future Educational and Occupational Plans for Brevard Community College Technical Program Students.

    ERIC Educational Resources Information Center

    Whitehead, Everett

    This practicum studies the future educational and/or occupational plans of 223 technical program students enrolled in Brevard Community College (BCC) during the Fall 1973 term in order to suggest adjustments in college procedures to facilitate student transition to continued college or to their chosen professions. The characteristics of technical…

  20. 25 CFR 900.28 - Is technical assistance available to an Indian tribe or tribal organization to avoid declination...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... tribal organization to avoid declination of a proposal? 900.28 Section 900.28 Indians BUREAU OF INDIAN... CONTRACTS UNDER THE INDIAN SELF-DETERMINATION AND EDUCATION ASSISTANCE ACT Declination Procedures § 900.28 Is technical assistance available to an Indian tribe or tribal organization to avoid declination of a...

  1. 75 FR 30387 - Improving Market and Planning Efficiency Through Improved Software; Notice of Agenda and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-01

    ... Market and Planning Efficiency Through Improved Software; Notice of Agenda and Procedures for Staff... planning models and software. The technical conference will be held from 8 a.m. to 5:30 p.m. (EDT) on June.... Agenda for AD10-12 Staff Technical Conference on Planning Models and Software Federal Energy Regulatory...

  2. Job Placement Rates for Graduates of Washington Community and Technical College Vocational Programs. Research Report No. 94-7.

    ERIC Educational Resources Information Center

    Seppanen, Loretta

    Each year, the Washington State Board for Community and Technical Colleges (SBCTC) compiles data on educational and job related outcomes for graduates of vocational preparation programs. The automated data matching procedure examines state unemployment insurance and benefits records, public post-secondary enrollments, U.S. Armed Forces…

  3. 50 CFR 91.13 - Technical requirements for design and submission of entry.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Technical requirements for design and submission of entry. 91.13 Section 91.13 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) MISCELLANEOUS PROVISIONS MIGRATORY BIRD HUNTING AND CONSERVATION STAMP CONTEST Procedures for Entering the...

  4. 50 CFR 91.13 - Technical requirements for design and submission of entry.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Technical requirements for design and submission of entry. 91.13 Section 91.13 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) MISCELLANEOUS PROVISIONS MIGRATORY BIRD HUNTING AND CONSERVATION STAMP CONTEST Procedures for Entering the...

  5. Task Inventory Construction. Evaluation of the Marine Corps Task Analysis Program. Technical Report No. 14.

    ERIC Educational Resources Information Center

    Kishi, Akemi

    To aid in the construction of effective task analysis inventories, this technical report discusses: (1) an optimum questionnaire length that adequately covers Marine tasks without unduly fatiguing respondents; (2) procedures for the phrasing of task statements to avoid ambiguities and be understandable to as broad a range of Marines as is…

  6. An Assessment of Workplace Skills Acquired by Students of Vocational and Technical Education Institutions

    ERIC Educational Resources Information Center

    Bakar, Ab Rahim; Mohamed, Shamsiah; Hamzah, Ramlah

    2013-01-01

    This study was performed to identify the employability skills of technical students from the Industrial Training Institutes (ITI) and Indigenous People's Trust Council (MARA) Skills Training Institutes (IKM) in Malaysia. The study sample consisted of 850 final year trainees of IKM and ITI. The sample was chosen by a random sampling procedure from…

  7. 76 FR 36539 - Office of the Assistant Secretary for Planning and Evaluation; Medicare Program; Meeting of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-22

    ... discussion is expected to be very technical in nature and will focus on the actuarial and economic... discussion is expected to focus on highly technical aspects of estimation involving economics and actuarial science. Panelists are not restricted, however, in the topics that they choose to discuss. Procedure and...

  8. 76 FR 19360 - Office of the Assistant Secretary for Planning and Evaluation; Medicare Program; Meeting of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-07

    ... be very technical in nature and will focus on the actuarial and economic assumptions and methods by... discussion is expected to focus on highly technical aspects of estimation involving economics and actuarial science. Panelists are not restricted, however, in the topics that they choose to discuss. Procedure and...

  9. Multi-Cultural Competency-Based Vocational Curricula. Clerical Clusters. Multi-Cultural Competency-Based Vocational/Technical Curricula Series.

    ERIC Educational Resources Information Center

    Hepburn, Larry; Shin, Masako

    This document, one of eight in a multi-cultural competency-based vocational/technical curricula series, is on clerical occupations. This program is designed to run 36 weeks and cover 10 instructional areas: beginning typing, typing I, typing II, duplicating, receptionist activities, general office procedures, operation of electronic calculator,…

  10. Third Progress and Information Report of the Vocational-Technical Education Consortium of States.

    ERIC Educational Resources Information Center

    Lee, Connie W.; And Others

    This description of major activities and accomplishments of the Vocational-Technical Education Consortium of the States (V-TECS) since the second progress report of May, 1975, is designed to provide the reader with a basic understanding of the processes and procedures used by the consortium in achieving its major goal: The production of catalogs…

  11. An Exploration of Alternative Scoring Methods Using Curriculum-Based Measurement in Early Writing

    ERIC Educational Resources Information Center

    Allen, Abigail A.; Poch, Apryl L.; Lembke, Erica S.

    2018-01-01

    This manuscript describes two empirical studies of alternative scoring procedures used with curriculum-based measurement in writing (CBM-W). Study 1 explored the technical adequacy of a trait-based rubric in first grade. Study 2 explored the technical adequacy of a trait-based rubric, production-dependent, and production-independent scores in…

  12. Materials Testing and Quality Control Soils, 3-28. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This instructional package on material testing and quality control of soils has been adapted from military curriculum materials for use in technical and vocational education programs. This short course presents basic information on soils as well as exploration, field identification, and laboratory procedures that will enable students completing…

  13. Dealing with the predicted increase in demand for revision total knee arthroplasty: challenges, risks and opportunities.

    PubMed

    Hamilton, D F; Howie, C R; Burnett, R; Simpson, A H R W; Patton, J T

    2015-06-01

    Worldwide rates of primary and revision total knee arthroplasty (TKA) are rising due to increased longevity of the population and the burden of osteoarthritis. Revision TKA is a technically demanding procedure generating outcomes which are reported to be inferior to those of primary knee arthroplasty, and with a higher risk of complication. Overall, the rate of revision after primary arthroplasty is low, but the number of patients currently living with a TKA suggests a large potential revision healthcare burden. Many patients are now outliving their prosthesis, and consideration must be given to how we are to provide the necessary capacity to meet the rising demand for revision surgery and how to maximise patient outcomes. The purpose of this review was to examine the epidemiology of, and risk factors for, revision knee arthroplasty, and to discuss factors that may enhance patient outcomes. ©2015 The British Editorial Society of Bone & Joint Surgery.

  14. Paediatric CT protocol optimisation: a design of experiments to support the modelling and optimisation process.

    PubMed

    Rani, K; Jahnen, A; Noel, A; Wolf, D

    2015-07-01

    In the last decade, several studies have emphasised the need to understand and optimise the computed tomography (CT) procedures in order to reduce the radiation dose applied to paediatric patients. To evaluate the influence of the technical parameters on the radiation dose and the image quality, a statistical model has been developed using the design of experiments (DOE) method that has been successfully used in various fields (industry, biology and finance) applied to CT procedures for the abdomen of paediatric patients. A Box-Behnken DOE was used in this study. Three mathematical models (contrast-to-noise ratio, noise and CTDI vol) depending on three factors (tube current, tube voltage and level of iterative reconstruction) were developed and validated. They will serve as a basis for the development of a CT protocol optimisation model. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Advancing Free Flight Through Human Factors: Workshop Report

    DOT National Transportation Integrated Search

    1995-08-01

    This report describes the results of the Advancing Free Flight Through Human : Factors technical workshop held on June 20 and 21, 1995. The purpose of this : technical workshop was to begin the process of identifying and solving human : factors issue...

  16. Myocardial infarction and subsequent death in a patient undergoing robotic prostatectomy.

    PubMed

    Thompson, Judy

    2009-10-01

    A 52-year-old patient, ASA physical status IV, undergoing a radical prostatectomy for cancer with a robotic system had a cardiac arrest 3 hours into the case. All attempts to resuscitate were unsuccessful, and several hours later he was pronounced dead. Underlying patient comorbidity and procedural issues contributed to the patient's death. The patient had a history of coronary artery disease that required the placement of drug-eluting stents 2 years before this surgical procedure. The preoperative cardiac evaluation and pharmacological management of patients with drug-eluting coronary stents are reviewed. There are a number of positional and technical considerations for patients undergoing robotic surgical procedures, especially in relation to the requirement of low-lithotomy and steep Trendelenburg positions. The cardiac and respiratory systems are especially vulnerable to the extreme and lengthy head-down position. The needed positioning, combined with the problems associated with insufflation, presents a unique challenge in anesthetic management. This course reviews the current literature on the surgical implications for patients with drug-eluting stents and the physiologic factors related to position and pneumoperitoneum and their associated stressors. By using a review of the contemporary literature, a best-evidence approach to anesthetic management is reviewed.

  17. 41 CFR 109-50.205 - Procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... DISPOSAL AUTHORITIES 50.2-Math and Science Equipment Gift Program § 109-50.205 Procedure. (a) The DOE... math and science projects where the equipment would further enhance the progress of the project. (e... will be used to improve math and science curricula or in the conduct of technical and scientific...

  18. 41 CFR 109-50.205 - Procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... DISPOSAL AUTHORITIES 50.2-Math and Science Equipment Gift Program § 109-50.205 Procedure. (a) The DOE... math and science projects where the equipment would further enhance the progress of the project. (e... will be used to improve math and science curricula or in the conduct of technical and scientific...

  19. 41 CFR 109-50.205 - Procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DISPOSAL AUTHORITIES 50.2-Math and Science Equipment Gift Program § 109-50.205 Procedure. (a) The DOE... math and science projects where the equipment would further enhance the progress of the project. (e... will be used to improve math and science curricula or in the conduct of technical and scientific...

  20. 41 CFR 109-50.205 - Procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... DISPOSAL AUTHORITIES 50.2-Math and Science Equipment Gift Program § 109-50.205 Procedure. (a) The DOE... math and science projects where the equipment would further enhance the progress of the project. (e... will be used to improve math and science curricula or in the conduct of technical and scientific...

Top