Misra, Ashish; Green, Michael R
2017-01-01
Alternative splicing is a regulated process that leads to inclusion or exclusion of particular exons in a pre-mRNA transcript, resulting in multiple protein isoforms being encoded by a single gene. With more than 90 % of human genes known to undergo alternative splicing, it represents a major source for biological diversity inside cells. Although in vitro splicing assays have revealed insights into the mechanisms regulating individual alternative splicing events, our global understanding of alternative splicing regulation is still evolving. In recent years, genome-wide RNA interference (RNAi) screening has transformed biological research by enabling genome-scale loss-of-function screens in cultured cells and model organisms. In addition to resulting in the identification of new cellular pathways and potential drug targets, these screens have also uncovered many previously unknown mechanisms regulating alternative splicing. Here, we describe a method for the identification of alternative splicing regulators using genome-wide RNAi screening, as well as assays for further validation of the identified candidates. With modifications, this method can also be adapted to study the splicing regulation of pre-mRNAs that contain two or more splice isoforms.
PERFORMANCE DEMONSTRATIONS OF ALTERNATIVE SCREEN RECLAMATION PRODUCTS FOR SCREEN PRINTING
This project evaluated environmentally-preferable products for the screen reclamation process In screen printing during month-long demonstrations at 23 printing facilities nationwide. hrough the Environmental Protection Agency (EPA) Design for the Environment Printing Project, pr...
A prototype software methodology for the rapid evaluation of biomanufacturing process options.
Chhatre, Sunil; Francis, Richard; O'Donovan, Kieran; Titchener-Hooker, Nigel J; Newcombe, Anthony R; Keshavarz-Moore, Eli
2007-10-01
A three-layered simulation methodology is described that rapidly evaluates biomanufacturing process options. In each layer, inferior options are screened out, while more promising candidates are evaluated further in the subsequent, more refined layer, which uses more rigorous models that require more data from time-consuming experimentation. Screening ensures laboratory studies are focused only on options showing the greatest potential. To simplify the screening, outputs of production level, cost and time are combined into a single value using multi-attribute-decision-making techniques. The methodology was illustrated by evaluating alternatives to an FDA (U.S. Food and Drug Administration)-approved process manufacturing rattlesnake antivenom. Currently, antivenom antibodies are recovered from ovine serum by precipitation/centrifugation and proteolyzed before chromatographic purification. Alternatives included increasing the feed volume, replacing centrifugation with microfiltration and replacing precipitation/centrifugation with a Protein G column. The best alternative used a higher feed volume and a Protein G step. By rapidly evaluating the attractiveness of options, the methodology facilitates efficient and cost-effective process development.
IRAS: High-Throughput Identification of Novel Alternative Splicing Regulators.
Zheng, S
2016-01-01
Alternative splicing is a fundamental regulatory process of gene expression. Defects in alternative splicing can lead to various diseases, and modification of disease-causing splicing events presents great therapeutic promise. Splicing outcome is commonly affected by extracellular stimuli and signaling cascades that converge on RNA-binding splicing regulators. These trans-acting factors recognize cis-elements in pre-mRNA transcripts to affect spliceosome assembly and splice site choices. Identification of these splicing regulators and/or upstream modulators has been difficult and traditionally done by piecemeal. High-throughput screening strategies to find multiple regulators of exon splicing have great potential to accelerate the discovery process, but typically confront low sensitivity and low specificity of screening assays. Here we describe a unique screening strategy, IRAS (identifying regulators of alternative splicing), using a pair of dual-output minigene reporters to allow for sensitive detection of exon splicing changes. Each dual-output reporter produces green fluorescent protein (GFP) and red fluorescent protein (RFP) fluorescent signals to assay the two spliced isoforms exclusively. The two complementary minigene reporters alter GFP/RFP output ratios in the opposite direction in response to splicing change. Applying IRAS in cell-based high-throughput screens allows sensitive and specific identification of splicing regulators and modulators for any alternative exons of interest. In comparison to previous high-throughput screening methods, IRAS substantially enhances the specificity of the screening assay. This strategy significantly eliminates false positives without sacrificing sensitive identification of true regulators of splicing. © 2016 Elsevier Inc. All rights reserved.
P2P is a computer-based tool that supports the comparison of process and product alternatives in terms of environmental impacts. This tool provides screening-level information for use in process design and in product LCA. Twenty one impact categories and data for approximately ...
Alternative Solvents/Technologies for Paint Stripping: Phase 1.
1994-03-01
processes . Three phases of study are defined: Phase I, identify alternate solvents/strippers and screen them; Phase II, field test solvent/ strippers...Section Title Page 1 Metal Refinishing Process - Immersion Method ............... 8 2 Phase Summary Chart ........................ 12 3 The...of the following: (a) nontoxic chemical formulations, (b) new process development, and (c) new coating reformulations. This program consists of three
Li, Wei; Zhang, Min; Wang, Mingyu; Han, Zhantao; Liu, Jiankai; Chen, Zhezhou; Liu, Bo; Yan, Yan; Liu, Zhu
2018-06-01
Brownfield sites pollution and remediation is an urgent environmental issue worldwide. The screening and assessment of remedial alternatives is especially complex owing to its multiple criteria that involves technique, economy, and policy. To help the decision-makers selecting the remedial alternatives efficiently, the criteria framework conducted by the U.S. EPA is improved and a comprehensive method that integrates multiple criteria decision analysis (MCDA) with numerical simulation is conducted in this paper. The criteria framework is modified and classified into three categories: qualitative, semi-quantitative, and quantitative criteria, MCDA method, AHP-PROMETHEE (analytical hierarchy process-preference ranking organization method for enrichment evaluation) is used to determine the priority ranking of the remedial alternatives and the solute transport simulation is conducted to assess the remedial efficiency. A case study was present to demonstrate the screening method in a brownfield site in Cangzhou, northern China. The results show that the systematic method provides a reliable way to quantify the priority of the remedial alternatives.
Popova, Daria; Stonier, Adam; Pain, David; Titchener‐Hooker, Nigel J.
2016-01-01
Abstract Increases in mammalian cell culture titres and densities have placed significant demands on primary recovery operation performance. This article presents a methodology which aims to screen rapidly and evaluate primary recovery technologies for their scope for technically feasible and cost‐effective operation in the context of high cell density mammalian cell cultures. It was applied to assess the performance of current (centrifugation and depth filtration options) and alternative (tangential flow filtration (TFF)) primary recovery strategies. Cell culture test materials (CCTM) were generated to simulate the most demanding cell culture conditions selected as a screening challenge for the technologies. The performance of these technology options was assessed using lab scale and ultra scale‐down (USD) mimics requiring 25–110mL volumes for centrifugation and depth filtration and TFF screening experiments respectively. A centrifugation and depth filtration combination as well as both of the alternative technologies met the performance selection criteria. A detailed process economics evaluation was carried out at three scales of manufacturing (2,000L, 10,000L, 20,000L), where alternative primary recovery options were shown to potentially provide a more cost‐effective primary recovery process in the future. This assessment process and the study results can aid technology selection to identify the most effective option for a specific scenario. PMID:27067803
To nudge or not to nudge: cancer screening programmes and the limits of libertarian paternalism.
Ploug, Thomas; Holm, Søren; Brodersen, John
2012-12-01
'Nudging--and the underlying idea 'libertarian paternalism'--to an increasing degree influences policy thinking in the healthcare sector. This article discusses the influence exerted upon a woman's choice of participation in the Danish breast screening programme in light of 'libertarian paternalism'. The basic tenet of 'libertarian paternalism' is outlined and the relationship between 'libertarian paternalism' and informed consent investigated. Key elements in the process of enrolling women into the Danish mammography screening programme are introduced. It is shown that for several reasons the influence exerted upon women's choices of participation cannot be justified within a welfare-enhancing libertarian paternalistic framework. The article suggests that screening programmes alternatively adopt a liberty-enhancing approach and considers the practical implications of this alternative.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LUECK, K.J.
2004-10-18
This report documents an engineering study conducted to evaluate alternatives for treating secondary waste in the secondary treatment train (STT) of the Hanford Site 200 Area Effluent Treatment Facility (ETF). The study evaluates ETF STT treatment alternatives and recommends preferred alternatives for meeting the projected future missions of the ETF. The preferred alternative(s) will process projected future ETF influents to produce a solid waste acceptable for final disposal on the Hanford Site. The main text of this report summarizes the ETF past and projected operations, lists the assumptions about projected operations that provide the basis for the engineering evaluation, andmore » summarizes the evaluation process. The evaluation process includes identification of available modifications to the current ETF process, screens those modifications for technical viability, evaluates the technically viable alternatives, and provides conclusions and recommendations based on that evaluation.« less
Alternatives Analysis for the Resumption of Transient Testing Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee Nelson
2013-11-01
An alternatives analysis was performed for resumption of transient testing. The analysis considered eleven alternatives – including both US international facilities. A screening process was used to identify two viable alternatives from the original eleven. In addition, the alternatives analysis includes a no action alternative as required by the National Environmental Policy Act (NEPA). The alternatives considered in this analysis included: 1. Restart the Transient Reactor Test Facility (TREAT) 2. Modify the Annular Core Research Reactor (ACRR) which includes construction of a new hot cell and installation of a new hodoscope. 3. No Action
ERIC Educational Resources Information Center
Duhon-Haynes, Gwendolyn; And Others
This paper examines alternative certification programs in terms of entrance requirements, supervision and mentoring, and post-certification professional support. A good alternative program uses rigorous screening processes to ensure the selection of qualified teacher interns; provides high-quality preservice training in methodology, classroom…
Navy Fuel Composition and Screening Tool (FCAST) v.2.5
2014-07-18
a major impediment to certification of these fuels as Fit-For- Purpose (FFP) for the U.S. Navy. A method whereby a candidate fuel could be rapidly...the U.S. Navy. A method whereby a candidate fuel could be rapidly screened for many FFP properties, using a minimal volume (< 1 mL), would overcome...mobility fuels with new alternative fuels, regardless of their source or processing methods . The Fuel Composition and Screening Tool (FCAST) was
Procedures for central auditory processing screening in schoolchildren.
Carvalho, Nádia Giulian de; Ubiali, Thalita; Amaral, Maria Isabel Ramos do; Santos, Maria Francisca Colella
2018-03-22
Central auditory processing screening in schoolchildren has led to debates in literature, both regarding the protocol to be used and the importance of actions aimed at prevention and promotion of auditory health. Defining effective screening procedures for central auditory processing is a challenge in Audiology. This study aimed to analyze the scientific research on central auditory processing screening and discuss the effectiveness of the procedures utilized. A search was performed in the SciELO and PUBMed databases by two researchers. The descriptors used in Portuguese and English were: auditory processing, screening, hearing, auditory perception, children, auditory tests and their respective terms in Portuguese. original articles involving schoolchildren, auditory screening of central auditory skills and articles in Portuguese or English. studies with adult and/or neonatal populations, peripheral auditory screening only, and duplicate articles. After applying the described criteria, 11 articles were included. At the international level, central auditory processing screening methods used were: screening test for auditory processing disorder and its revised version, screening test for auditory processing, scale of auditory behaviors, children's auditory performance scale and Feather Squadron. In the Brazilian scenario, the procedures used were the simplified auditory processing assessment and Zaidan's battery of tests. At the international level, the screening test for auditory processing and Feather Squadron batteries stand out as the most comprehensive evaluation of hearing skills. At the national level, there is a paucity of studies that use methods evaluating more than four skills, and are normalized by age group. The use of simplified auditory processing assessment and questionnaires can be complementary in the search for an easy access and low-cost alternative in the auditory screening of Brazilian schoolchildren. Interactive tools should be proposed, that allow the selection of as many hearing skills as possible, validated by comparison with the battery of tests used in the diagnosis. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Remedial Action Assessment System: A computer-based methodology for conducting feasibility studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.K.; Buelt, J.L.; Stottlemyre, J.A.
1991-02-01
Because of the complexity and number of potential waste sites facing the US Department of Energy (DOE) for potential cleanup, DOE is supporting the development of a computer-based methodology to streamline the remedial investigation/feasibility study process. The Remedial Action Assessment System (RAAS), can be used for screening, linking, and evaluating established technology processes in support of conducting feasibility studies. It is also intended to do the same in support of corrective measures studies. The user interface employs menus, windows, help features, and graphical information while RAAS is in operation. Object-oriented programming is used to link unit processes into sets ofmore » compatible processes that form appropriate remedial alternatives. Once the remedial alternatives are formed, the RAAS methodology can evaluate them in terms of effectiveness, implementability, and cost. RAAS will access a user-selected risk assessment code to determine the reduction of risk after remedial action by each recommended alternative. The methodology will also help determine the implementability of the remedial alternatives at a site and access cost estimating tools to provide estimates of capital, operating, and maintenance costs. This paper presents the characteristics of two RAAS prototypes currently being developed. These include the RAAS Technology Information System, which accesses graphical, tabular and textual information about technologies, and the main RAAS methodology, which screens, links, and evaluates remedial technologies. 4 refs., 3 figs., 1 tab.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
...We, the U.S. Fish and Wildlife Service (Service) and the California Department of Fish and Wildlife (CDFW), announce that the record of decision (ROD) for the Llano Seco Riparian Sanctuary Unit Restoration and Princeton, Codora, Glenn & Provident Irrigation Districts (PCGID-PID) Pumping Plan/Fish Screen Facility Protection Project is now available. The ROD includes a statement of the decisions made, the basis for the decisions, a description of the alternative considered, a description of the environmentally preferable alternative, an overview of the measures to minimize environmental impacts, and a summary of public involvement in the decision-making process.
An approach to quantitative sustainability assessment in the early stages of process design.
Tugnoli, Alessandro; Santarelli, Francesco; Cozzani, Valerio
2008-06-15
A procedure was developed for the quantitative assessment of key performance indicators suitable for the sustainability analysis of alternative processes, mainly addressing the early stages of process design. The methodology was based on the calculation of a set of normalized impact indices allowing a direct comparison of the additional burden of each process alternative on a selected reference area. Innovative reference criteria were developed to compare and aggregate the impact indicators on the basis of the site-specific impact burden and sustainability policy. An aggregation procedure also allows the calculation of overall sustainability performance indicators and of an "impact fingerprint" of each process alternative. The final aim of the method is to support the decision making process during process development, providing a straightforward assessment of the expected sustainability performances. The application of the methodology to case studies concerning alternative waste disposal processes allowed a preliminary screening of the expected critical sustainability impacts of each process. The methodology was shown to provide useful results to address sustainability issues in the early stages of process design.
Determining the carcinogenicity and carcinogenic potency of new chemicals is both a labor-intensive and time-consuming process. In order to expedite the screening process, there is a need to either: (1) identify alternative toxicity measures (shorter duration) that may be used as...
Vanstone, Meredith; Kinsella, Elizabeth Anne; Nisker, Jeff
2012-03-01
The 2011 SOGC clinical practice guideline "Prenatal Screening for Fetal Aneuploidy in Singleton Pregnancies" recommends that clinicians offer prenatal screening to all pregnant women and provide counselling in a non-directive manner. Non-directive counselling is intended to facilitate autonomous decision-making and remove the clinician's views regarding a particular course of action. However, recent research in genetic counselling raises concerns that non-directive counselling is neither possible nor desirable, and that it may not be the best way to facilitate informed choice. We propose an alternative model of information-sharing specific to prenatal screening that combines attributes of the models of informative decision-making and shared decision-making. Our proposed model is intended to provide clinicians with a strategy to communicate information about prenatal screening in a way that facilitates a shared deliberative process and autonomous decision-making. Our proposed model may better prepare a pregnant woman to make an informed choice about participating in prenatal screening on the basis of her consideration of the medical information provided by her clinician and her particular circumstances and values.
Estimating the cost of cervical cancer screening in five developing countries
Goldhaber-Fiebert, Jeremy D; Goldie, Sue J
2006-01-01
Background Cost-effectiveness analyses (CEAs) can provide useful information to policymakers concerned with the broad allocation of resources as well as to local decision makers choosing between different options for reducing the burden from a single disease. For the latter, it is important to use country-specific data when possible and to represent cost differences between countries that might make one strategy more or less attractive than another strategy locally. As part of a CEA of cervical cancer screening in five developing countries, we supplemented limited primary cost data by developing other estimation techniques for direct medical and non-medical costs associated with alternative screening approaches using one of three initial screening tests: simple visual screening, HPV DNA testing, and cervical cytology. Here, we report estimation methods and results for three cost areas in which data were lacking. Methods To supplement direct medical costs, including staff, supplies, and equipment depreciation using country-specific data, we used alternative techniques to quantify cervical cytology and HPV DNA laboratory sample processing costs. We used a detailed quantity and price approach whose face validity was compared to an adaptation of a US laboratory estimation methodology. This methodology was also used to project annual sample processing capacities for each laboratory type. The cost of sample transport from the clinic to the laboratory was estimated using spatial models. A plausible range of the cost of patient time spent seeking and receiving screening was estimated using only formal sector employment and wages as well as using both formal and informal sector participation and country-specific minimum wages. Data sources included primary data from country-specific studies, international databases, international prices, and expert opinion. Costs were standardized to year 2000 international dollars using inflation adjustment and purchasing power parity. Results Cervical cytology laboratory processing costs were I$1.57–3.37 using the quantity and price method compared to I$1.58–3.02 from the face validation method. HPV DNA processing costs were I$6.07–6.59. Rural laboratory transport costs for cytology were I$0.12–0.64 and I$0.14–0.74 for HPV DNA laboratories. Under assumptions of lower resource efficiency, these estimates increased to I$0.42–0.83 and I$0.54–1.06. Estimates of the value of an hour of patient time using only formal sector participation were I$0.07–4.16, increasing to I$0.30–4.80 when informal and unpaid labor was also included. The value of patient time for traveling, waiting, and attending a screening visit was I$0.68–17.74. With the total cost of screening for cytology and HPV DNA testing ranging from I$4.85–40.54 and I$11.30–48.77 respectively, the cost of the laboratory transport, processing, and patient time accounted for 26–66% and 33–65% of the total costs. From a payer perspective, laboratory transport and processing accounted for 18–48% and 25–60% of total direct medical costs of I$4.11–19.96 and I$10.57–28.18 respectively. Conclusion Cost estimates of laboratory processing, sample transport, and patient time account for a significant proportion of total cervical cancer screening costs in five developing countries and provide important inputs for CEAs of alternative screening modalities. PMID:16887041
1996-04-01
This study is to screen and evaluate remediation alternatives for IRP sites at Alpena CR TC, Alpena , MI. The purpose of this FS is to develop, screen... Alpena CRTC. The first step in the PS process is to identify the RAOs and general response actions (GRAs). RAOs consist of medium-specific or site
Investigation of Advanced Processed Single-Crystal Turbine Blade Alloys
NASA Technical Reports Server (NTRS)
Peters, B. J.; Biondo, C. M.; DeLuca, D. P.
1995-01-01
This investigation studied the influence of thermal processing and microstructure on the mechanical properties of the single-crystal, nickel-based superalloys PWA 1482 and PWA 1484. The objective of the program was to develop an improved single-crystal turbine blade alloy that is specifically tailored for use in hydrogen fueled rocket engine turbopumps. High-gradient casting, hot isostatic pressing (HIP), and alternate heat treatment (HT) processing parameters were developed to produce pore-free, eutectic-free microstructures with different (gamma)' precipitate morphologies. Test materials were cast in high thermal gradient solidification (greater than 30 C/cm (137 F/in.)) casting furnaces for reduced dendrite arm spacing, improved chemical homogeneity, and reduced interdendritic pore size. The HIP processing was conducted in 40 cm (15.7 in.) diameter production furnaces using a set of parameters selected from a trial matrix study. Metallography was conducted on test samples taken from each respective trial run to characterize the as-HIP microstructure. Post-HIP alternate HT processes were developed for each of the two alloys. The goal of the alternate HT processing was to fully solution the eutectic gamma/(gamma)' phase islands and to develop a series of modified (gamma)' morphologies for subsequent characterization testing. This was accomplished by slow cooling through the (gamma)' solvus at controlled rates to precipitate volume fractions of large (gamma)'. Post-solution alternate HT parameters were established for each alloy providing additional volume fractions of finer precipitates. Screening tests included tensile, high-cycle fatigue (HCF), smooth and notched low-cycle fatigue (LCF), creep, and fatigue crack growth evaluations performed in air and high pressure (34.5 MPa (5 ksi)) hydrogen at room and elevated temperature. Under the most severe embrittling conditions (HCF and smooth and notched LCF in 34.5 MPa (5 ksi) hydrogen at 20 C (68 F), screening test results showed increases in fatigue life typically on the order of 1OX, when compared to the current Space Shuttle Main Engine (SSME) Alternate Turbopump (AT) blade alloy (PWA 1480).
Adaptive Gaussian mixture models for pre-screening in GPR data
NASA Astrophysics Data System (ADS)
Torrione, Peter; Morton, Kenneth, Jr.; Besaw, Lance E.
2011-06-01
Due to the large amount of data generated by vehicle-mounted ground penetrating radar (GPR) antennae arrays, advanced feature extraction and classification can only be performed on a small subset of data during real-time operation. As a result, most GPR based landmine detection systems implement "pre-screening" algorithms to processes all of the data generated by the antennae array and identify locations with anomalous signatures for more advanced processing. These pre-screening algorithms must be computationally efficient and obtain high probability of detection, but can permit a false alarm rate which might be higher than the total system requirements. Many approaches to prescreening have previously been proposed, including linear prediction coefficients, the LMS algorithm, and CFAR-based approaches. Similar pre-screening techniques have also been developed in the field of video processing to identify anomalous behavior or anomalous objects. One such algorithm, an online k-means approximation to an adaptive Gaussian mixture model (GMM), is particularly well-suited to application for pre-screening in GPR data due to its computational efficiency, non-linear nature, and relevance of the logic underlying the algorithm to GPR processing. In this work we explore the application of an adaptive GMM-based approach for anomaly detection from the video processing literature to pre-screening in GPR data. Results with the ARA Nemesis landmine detection system demonstrate significant pre-screening performance improvements compared to alternative approaches, and indicate that the proposed algorithm is a complimentary technique to existing methods.
Installation Restoration Program (IRP). Operable Unit B1 Remedial Investigation/Feasibility Study
1993-07-01
Alternative Evaluation Criteria ......................... 8-2 8-2 Remedial Alternative Evaluation Criteria Rating System ................ 8-3 8-3...ies, various technologies and process options relative numerical rating system was developed were identified and screened on the basis of (see Table 8-2...extensive paving and PCBs were found (north/central ditch). This storm drainage system , and because of the ditch was paved with asphalt in 1981; before
Foster-Chang, Sarah A; Manning, Mary L; Chandler, Laura
2014-11-01
Selection of the most suitable test(s) for detection of Mycobacterium tuberculosis (TB) infection should be based on purpose, setting, effectiveness, and cost. Two tests are available to screen for latent TB: the tuberculin skin test (TST) and the more recent interferon-gamma release assays (IGRAs). Based on the administrative, logistic, and technical ease of use, an IGRA trial was initiated by the occupational health department at an urban Veteran's Administration health care facility for TB screening of new employees. As a result, new employees completing the pre-placement process within the organization's designated 14 days increased from 77% to 97%, new employee clearance to work time decreased from 13.18 to 5.91 days, and new employee TB screening costs were reduced by 40%. The IGRA is an acceptable alternative to the TST and has significant potential to improve the process of pre-placement TB screening. Copyright 2014, SLACK Incorporated.
Recent trends in digital halftoning
NASA Astrophysics Data System (ADS)
Delabastita, Paul A.
1997-02-01
Screening is perhaps the oldest form of image processing. The word refers to the mechanical cross line screens that were used at the beginning of this century for the purpose of photomechanical reproduction. Later on, these mechanical screens were replaced by photographic contact screens that enabled significantly improved process control. In the early eighties, the optical screening on graphic arts scanners was replaced by a combination of laser optics and electronic screening. The algorithms, however, were still digital implementations of the original optical methods. The printing needs in the fast growing computer and software industry gave birth to a number of alternative printing technologies such as electrophotographic and inkjet printing. Originally these deices were only designed for printing text, but soon people started experimenting and using them for printing images. The relatively low spatial resolutions of these new devices however made complete review of 'the screening issue' necessary to achieve an acceptable image quality. In this paper a number of recent developments in screening technology are summarized. Special attention is given to the interaction that exists between a halftone screen and the printing devices on which they are rendered including the color mixing behavior. Improved screening techniques are presented that take advantage of modeling the physical behavior of the rendering device.
Considerations in Deciding to Treat Contaminated Unsaturated Soils In Situ
The purpose of this Issue Paper is to assist the user in deciding if in situ treatment of contaminated soil is a potentially feasible remedial alternative and to assist in the process of reviewing and screening in situ technologies.
Public stated preferences and predicted uptake for genome-based colorectal cancer screening
2014-01-01
Background Emerging developments in nanomedicine allow the development of genome-based technologies for non-invasive and individualised screening for diseases such as colorectal cancer. The main objective of this study was to measure user preferences for colorectal cancer screening using a nanopill. Methods A discrete choice experiment was used to estimate the preferences for five competing diagnostic techniques including the nanopill and iFOBT. Alternative screening scenarios were described using five attributes namely: preparation involved, sensitivity, specificity, complication rate and testing frequency. Fourteen random and two fixed choice tasks, each consisting of three alternatives, were offered to 2225 individuals. Data were analysed using the McFadden conditional logit model. Results Thirteen hundred and fifty-six respondents completed the questionnaire. The most important attributes (and preferred levels) were the screening technique (nanopill), sensitivity (100%) and preparation (no preparation). Stated screening uptake for the nanopill was 79%, compared to 76% for iFOBT. In the case of screening with the nanopill, the percentage of people preferring not to be screened would be reduced from 19.2% (iFOBT) to 16.7%. Conclusions Although the expected benefits of nanotechnology based colorectal cancer screening are improved screening uptake, assuming more accurate test results and less preparation involved, the relative preference of the nanopill is only slightly higher than the iFOBT. Estimating user preferences during the development of diagnostic technologies could be used to identify relative performance, including perceived benefits and harms compared to competitors allowing for significant changes to be made throughout the process of development. PMID:24642027
de Brugerolle, Anne
2007-01-01
SkinEthic Laboratories is a France-based biotechnology company recognised as the world leader in tissue engineering. SkinEthic is devoted to develop and produce reliable and robust in vitro alternative methods to animal use in cosmetic, chemical and pharmaceutical industries. SkinEthic models provide relevant tools for efficacy and safety screening tests in order to support an integrated decision-making during research and development phases. Some screening tests are referenced and validated as alternatives to animal use (Episkin), others are in the process of validation under ECVAM and OECD guidelines. SkinEthic laboratories provide a unique and joined experience of more than 20 years from Episkin SNC and SkinEthic SA. Their unique cell culture process allows in vitro reconstructed human tissues with well characterized histology, functionality and ultrastructure features to be mass produced. Our product line includes skin models: a reconstructed human epidermis with a collagen layer, Episkin, reconstructed human epidermis without or with melanocytes (with a tanning degree from phototype II to VI) and a reconstructed human epithelium, i.e. cornea, and other mucosa, i.e. oral, gingival, oesophageal and vaginal. Our philosophy is based on 3 main commitments: to support our customers by providing robust and reliable models, to ensure training and education in using validated protocols, allowing a large array of raw materials, active ingredients and finished products in solid, liquid, powder, cream or gel form to be screened, and, to provide a dedicated service to our partners.
Alternative Fuel Research in Fischer-Tropsch Synthesis
NASA Technical Reports Server (NTRS)
Surgenor, Angela D.; Klettlinger, Jennifer L.; Yen, Chia H.; Nakley, Leah M.
2011-01-01
NASA Glenn Research Center has recently constructed an Alternative Fuels Laboratory which is solely being used to perform Fischer-Tropsch (F-T) reactor studies, novel catalyst development and thermal stability experiments. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch synthesis. The purpose of this test facility is to conduct bench scale Fischer-Tropsch (F-T) catalyst screening experiments while focusing on reducing energy inputs, reducing CO2 emissions and increasing product yields within the F-T process. Fischer-Tropsch synthesis is considered a gas to liquid process which reacts syn-gas (a gaseous mixture of hydrogen and carbon monoxide), over the surface of a catalyst material which is then converted into liquids of various hydrocarbon chain length and product distributions1. These hydrocarbons can then be further processed into higher quality liquid fuels such as gasoline and diesel. The experiments performed in this laboratory will enable the investigation of F-T reaction kinetics to focus on newly formulated catalysts, improved process conditions and enhanced catalyst activation methods. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor used solely for cobalt catalyst activation.
Genome-wide CRISPR screen identifies HNRNPL as a prostate cancer dependency regulating RNA splicing.
Fei, Teng; Chen, Yiwen; Xiao, Tengfei; Li, Wei; Cato, Laura; Zhang, Peng; Cotter, Maura B; Bowden, Michaela; Lis, Rosina T; Zhao, Shuang G; Wu, Qiu; Feng, Felix Y; Loda, Massimo; He, Housheng Hansen; Liu, X Shirley; Brown, Myles
2017-06-27
Alternative RNA splicing plays an important role in cancer. To determine which factors involved in RNA processing are essential in prostate cancer, we performed a genome-wide CRISPR/Cas9 knockout screen to identify the genes that are required for prostate cancer growth. Functional annotation defined a set of essential spliceosome and RNA binding protein (RBP) genes, including most notably heterogeneous nuclear ribonucleoprotein L (HNRNPL). We defined the HNRNPL-bound RNA landscape by RNA immunoprecipitation coupled with next-generation sequencing and linked these RBP-RNA interactions to changes in RNA processing. HNRNPL directly regulates the alternative splicing of a set of RNAs, including those encoding the androgen receptor, the key lineage-specific prostate cancer oncogene. HNRNPL also regulates circular RNA formation via back splicing. Importantly, both HNRNPL and its RNA targets are aberrantly expressed in human prostate tumors, supporting their clinical relevance. Collectively, our data reveal HNRNPL and its RNA clients as players in prostate cancer growth and potential therapeutic targets.
Volunteers for biomedical research. Recruitment and screening of normal controls.
Shtasel, D L; Gur, R E; Mozley, P D; Richards, J; Taleff, M M; Heimberg, C; Gallacher, F; Gur, R C
1991-11-01
We examined the process of accruing healthy control subjects for biomedical research on brain function. Of 1670 responders to newspaper advertising, 23.1% were uninterested when learning more about the studies, and 50.9% of those remaining were found by structured telephone screening to meet exclusionary criteria for having a history of psychiatric, neurologic, or medical disease that might affect brain function. Of 312 volunteers passing the telephone screening who came to an in-person evaluation by a physician and agreed to participate, 49.7% were found to meet exclusionary criteria, and only 157 were admitted to the study. This underscores the importance of attending to the issue of screening and assessment of "normal volunteers." Alternative strategies should be considered for enriching the pool.
Lowry, Kathryn P.; Lee, Janie M.; Kong, Chung Y.; McMahon, Pamela M.; Gilmore, Michael E.; Cott Chubiz, Jessica E.; Pisano, Etta D.; Gatsonis, Constantine; Ryan, Paula D.; Ozanne, Elissa M.; Gazelle, G. Scott
2011-01-01
Background While breast cancer screening with mammography and MRI is recommended for BRCA mutation carriers, there is no current consensus on the optimal screening regimen. Methods We used a computer simulation model to compare six annual screening strategies [film mammography (FM), digital mammography (DM), FM and magnetic resonance imaging (MRI) or DM and MRI contemporaneously, and alternating FM/MRI or DM/MRI at six-month intervals] beginning at ages 25, 30, 35, and 40, and two strategies of annual MRI with delayed alternating DM/FM to clinical surveillance alone. Strategies were evaluated without and with mammography-induced breast cancer risk, using two models of excess relative risk. Input parameters were obtained from the medical literature, publicly available databases, and calibration. Results Without radiation risk effects, alternating DM/MRI starting at age 25 provided the highest life expectancy (BRCA1: 72.52 years, BRCA2: 77.63 years). When radiation risk was included, a small proportion of diagnosed cancers were attributable to radiation exposure (BRCA1: <2%, BRCA2: <4%). With radiation risk, alternating DM/MRI at age 25 or annual MRI at age 25/delayed alternating DM at age 30 were most effective, depending on the radiation risk model used. Alternating DM/MRI starting at age 25 also had the highest number of false-positive screens/person (BRCA1: 4.5, BRCA2: 8.1). Conclusions Annual MRI at 25/delayed alternating DM at age 30 is likely the most effective screening strategy in BRCA mutation carriers. Screening benefits, associated risks and personal acceptance of false-positive results, should be considered in choosing the optimal screening strategy for individual women. PMID:21935911
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia-Montero, Luis G., E-mail: luisgonzaga.garcia@upm.e; Lopez, Elena, E-mail: elopez@caminos.upm.e; Monzon, Andres, E-mail: amonzon@caminos.upm.e
Most Strategic Environmental Assessment (SEA) research has been concerned with SEA as a procedure, and there have been relatively few developments and tests of analytical methodologies. The first stage of the SEA is the 'screening', which is the process whereby a decision is taken on whether or not SEA is required for a particular programme or plan. The effectiveness of screening and SEA procedures will depend on how well the assessment fits into the planning from the early stages of the decision-making process. However, it is difficult to prepare the environmental screening for an infrastructure plan involving a whole country.more » To be useful, such methodologies must be fast and simple. We have developed two screening tools which would make it possible to estimate promptly the overall impact an infrastructure plan might have on biodiversity and global warming for a whole country, in order to generate planning alternatives, and to determine whether or not SEA is required for a particular infrastructure plan.« less
Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.
Doyle, Kelly; Strathmann, Frederick G
2017-02-01
This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.
Pluripotent stem cell derived hepatocyte like cells and their potential in toxicity screening.
Greenhough, Sebastian; Medine, Claire N; Hay, David C
2010-12-30
Despite considerable progress in modelling human liver toxicity, the requirement still exists for efficient, predictive and cost effective in vitro models to reduce attrition during drug development. Thousands of compounds fail in this process, with hepatotoxicity being one of the significant causes of failure. The cost of clinical studies is substantial, therefore it is essential that toxicological screening is performed early on in the drug development process. Human hepatocytes represent the gold standard model for evaluating drug toxicity, but are a limited resource. Current alternative models are based on immortalised cell lines and animal tissue, but these are limited by poor function, exhibit species variability and show instability in culture. Pluripotent stem cells are an attractive alternative as they are capable of self-renewal and differentiation to all three germ layers, and thereby represent a potentially inexhaustible source of somatic cells. The differentiation of human embryonic stem cells and induced pluripotent stem cells to functional hepatocyte like cells has recently been reported. Further development of this technology could lead to the scalable production of hepatocyte like cells for liver toxicity screening and clinical therapies. Additionally, induced pluripotent stem cell derived hepatocyte like cells may permit in vitro modelling of gene polymorphisms and genetic diseases. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Development and Validation of Cognitive Screening Instruments.
ERIC Educational Resources Information Center
Jarman, Ronald F.
The author suggests that most research on the early detection of learning disabilities is characterisized by an ineffective and a theoretical method of selecting and validating tasks. An alternative technique is proposed, based on a neurological theory of cognitive processes, whereby task analysis is a first step, with empirical analyses as…
A Cost-Utility Analysis of Prostate Cancer Screening in Australia.
Keller, Andrew; Gericke, Christian; Whitty, Jennifer A; Yaxley, John; Kua, Boon; Coughlin, Geoff; Gianduzzo, Troy
2017-02-01
The Göteborg randomised population-based prostate cancer screening trial demonstrated that prostate-specific antigen (PSA)-based screening reduces prostate cancer deaths compared with an age-matched control group. Utilising the prostate cancer detection rates from this study, we investigated the clinical and cost effectiveness of a similar PSA-based screening strategy for an Australian population of men aged 50-69 years. A decision model that incorporated Markov processes was developed from a health system perspective. The base-case scenario compared a population-based screening programme with current opportunistic screening practices. Costs, utility values, treatment patterns and background mortality rates were derived from Australian data. All costs were adjusted to reflect July 2015 Australian dollars (A$). An alternative scenario compared systematic with opportunistic screening but with optimisation of active surveillance (AS) uptake in both groups. A discount rate of 5 % for costs and benefits was utilised. Univariate and probabilistic sensitivity analyses were performed to assess the effect of variable uncertainty on model outcomes. Our model very closely replicated the number of deaths from both prostate cancer and background mortality in the Göteborg study. The incremental cost per quality-adjusted life-year (QALY) for PSA screening was A$147,528. However, for years of life gained (LYGs), PSA-based screening (A$45,890/LYG) appeared more favourable. Our alternative scenario with optimised AS improved cost utility to A$45,881/QALY, with screening becoming cost effective at a 92 % AS uptake rate. Both modelled scenarios were most sensitive to the utility of patients before and after intervention, and the discount rate used. PSA-based screening is not cost effective compared with Australia's assumed willingness-to-pay threshold of A$50,000/QALY. It appears more cost effective if LYGs are used as the relevant outcome, and is more cost effective than the established Australian breast cancer screening programme on this basis. Optimised utilisation of AS increases the cost effectiveness of prostate cancer screening dramatically.
Preventive Screening of Women Who Use Complementary and Alternative Medicine Providers
Tyree, Patrick T.; Lafferty, William E.
2009-01-01
Abstract Background Many women use complementary and alternative medicine (CAM). Although CAM use has been associated with reductions in conventionally recommended pediatric preventive care (e.g., vaccination), little is known about associations between CAM use and receipt of recommended preventive screening in women. Methods Using Washington State insurance data from 2000 to 2003, the authors generated clustered logistic regression models, examining associations between provider-based CAM use and receipt of screening tests for Chlamydia trachomatis, breast cancer, and cervical cancer: (1) contrasting women who used CAM providers only (alternative use) and women who used both conventional and CAM providers (complementary use) with women who used conventional care only and (2) testing associations between screening and use of four specific CAM provider types—naturopathic physicians, chiropractors, massage therapists, and acupuncturists. Results Both alternative and complementary use was associated with reduced Chlamydia screening. Cancer screening increased with complementary use but decreased with alternative use of CAM. Use of naturopathy was associated with decreased mammography, whereas all four CAM therapies were positively associated with Papanicolaou testing. Conclusions When used in conjunction with conventional care, use of provider-based CAM may signal high interest in various types of health-promoting behavior, including cancer screening. Negative associations between CAM and Chlamydia screening and between naturopathy and mammography require additional study. Interventions with CAM providers and their patients, aimed at improving rates of conventionally recommended screening, might encourage greater focus on preventive care, an important task when CAM providers serve as women's only contact with the healthcare system. PMID:19630554
He, Qiwei; Veldkamp, Bernard P; Glas, Cees A W; de Vries, Theo
2017-03-01
Patients' narratives about traumatic experiences and symptoms are useful in clinical screening and diagnostic procedures. In this study, we presented an automated assessment system to screen patients for posttraumatic stress disorder via a natural language processing and text-mining approach. Four machine-learning algorithms-including decision tree, naive Bayes, support vector machine, and an alternative classification approach called the product score model-were used in combination with n-gram representation models to identify patterns between verbal features in self-narratives and psychiatric diagnoses. With our sample, the product score model with unigrams attained the highest prediction accuracy when compared with practitioners' diagnoses. The addition of multigrams contributed most to balancing the metrics of sensitivity and specificity. This article also demonstrates that text mining is a promising approach for analyzing patients' self-expression behavior, thus helping clinicians identify potential patients from an early stage.
Coplanar back contacts for thin silicon solar cells
NASA Technical Reports Server (NTRS)
Thornhill, J. W.; Sipperly, W. E.
1980-01-01
A process for fabricating 2 to 3 mil wraparound solar cells was formulated. Sample thin wraparound cells were fabricated using this process. The process used a reinforced perimeter construction to reduce the breakage that occurs during handling of the wafers. A retracting piston post was designed and fabricated to help minimize the breakage that occurs during the screen printing process. Two alternative methods of applying the aluminum back surface field were investigated. In addition to the standard screen printed back surface field, both spin-on and evaporated aluminum techniques were researched. Neither spin-on nor evaporated aluminum made any noticeable improvement over the screen printing technique. A fine screen mesh was chosen for the application of the aluminum paste back surface field. The optimum time and temperature for firing the aluminum turned out to be thirty seconds at 850 C. The development work on the dielectric included looking at three dielectrics for the wraparound application. Transene 1000, Thick Film Systems 1126RCB and an in house formulation 61-2-2A were all tested. Cells with pre-dielectric thickness of 3.0-0-3.5 mils using Transene 1000 as the wraparound dielectric and the procedure outlined above showed an average efficiency of 10.7 percent. Thinner cells were fabricated, but had an unacceptable yield and efficiency.
American Cancer Society Lung Cancer Screening Guidelines
Wender, Richard; Fontham, Elizabeth T. H.; Barrera, Ermilo; Colditz, Graham A.; Church, Timothy R.; Ettinger, David S.; Etzioni, Ruth; Flowers, Christopher R.; Gazelle, G. Scott; Kelsey, Douglas K.; LaMonte, Samuel J.; Michaelson, James S.; Oeffinger, Kevin C.; Shih, Ya-Chen Tina; Sullivan, Daniel C.; Travis, William; Walter, Louise; Wolf, Andrew M. D.; Brawley, Otis W.; Smith, Robert A.
2013-01-01
Findings from the National Cancer Institute’s National Lung Screening Trial established that lung cancer mortality in specific high-risk groups can be reduced by annual screening with low-dose computed tomography. These findings indicate that the adoption of lung cancer screening could save many lives. Based on the results of the National Lung Screening Trial, the American Cancer Society is issuing an initial guideline for lung cancer screening. This guideline recommends that clinicians with access to high-volume, high-quality lung cancer screening and treatment centers should initiate a discussion about screening with apparently healthy patients aged 55 years to 74 years who have at least a 30-pack-year smoking history and who currently smoke or have quit within the past 15 years. A process of informed and shared decision-making with a clinician related to the potential benefits, limitations, and harms associated with screening for lung cancer with low-dose computed tomography should occur before any decision is made to initiate lung cancer screening. Smoking cessation counseling remains a high priority for clinical attention in discussions with current smokers, who should be informed of their continuing risk of lung cancer. Screening should not be viewed as an alternative to smoking cessation. PMID:23315954
NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Wollen, Mark; Bakke, Victor; Baker, James
2012-01-01
While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-06
The U.S. Army Environmental Center directed ABB Environmental Services, Inc. (ABB-ES), under Contract No. DAAA15-91-D-0008, to conduct a Remedial Investigation (RI) and Feasibility Study (FS) to address the contamination of soil and groundwater at Area of Contamination (AOC) 43J at Fort Devens, Massachusetts. This FS Report is prepared as part of the FS process in accordance with the 1988 U.S. Environmental Protection Agency (USEPA) guidance document entitled Guidance for Conducting Remedial Investigations and Feasibility Studies under CERCLA. The purpose of the FS Report is to initially identify and screen potentially feasible alternatives to control human health and environmental risks atmore » AOC 43J. Following this screening, the FS Report presents a detailed analysis and comparative analysis of the retained alternatives.« less
Adequacy of published screening criteria for retinopathy of prematurity.
Taranath, Deepa A; Oh, Dickson D-S; Keane, Miriam C; Fabel, Helen; Marshall, Peter
2016-03-01
Criteria for screening preterm infants for retinopathy of prematurity vary around the world. We aimed to analyse the efficacy of alternative screening criteria. We collected retrospective data at a tertiary level neonatal nursery. Our participants were 1007 babies, born between 1997 and 2011, at <32 weeks gestational age or <1500 g birth weight (as recommended by the National Health and Medical Research Council in 1996), who had completed follow-up to full retinal vascularization, with defined presence or absence of retinopathy of prematurity. We determined whether disease would be detected using an alternative Australian screening model (gestational age <30 weeks or birth weight <1250 g) or screening criteria utilized in developed countries with similar standards of neonatal care. Detection of retinopathy of prematurity is our main outcome. Using several of the alternative criteria, two neonates with clinically significant retinopathy of prematurity, one of whom required laser treatment to preserve sight, would not have been screened, and their disease may have gone undetected. Use of <30 weeks gestational age or <1500 g birth weight as the criteria would still have screened these infants but would have reduced the number of infants screened by 24.9%. Some commonly utilized international screening criteria for retinopathy of prematurity may risk clinically significant cases being missed and others may screen babies unnecessarily. Alternative criteria should be considered and '<30 weeks gestational age and/or <1500 g birth weight' appears a viable option. © 2015 Royal Australian and New Zealand College of Ophthalmologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W., II
1993-01-01
One of the initial stages in ecological risk assessment of hazardous waste sites is the screening of contaminants to determine which, if any, of them are worthy of further consideration; this process is termed contaminant screening. Screening is performed by comparing concentrations in ambient media to benchmark concentrations that are either indicative of a high likelihood of significant effects (upper screening benchmarks) or of a very low likelihood of significant effects (lower screening benchmarks). Exceedance of an upper screening benchmark indicates that the chemical in question is clearly of concern and remedial actions are likely to be needed. Exceedance ofmore » a lower screening benchmark indicates that a contaminant is of concern unless other information indicates that the data are unreliable or the comparison is inappropriate. Chemicals with concentrations below the lower benchmark are not of concern if the ambient data are judged to be adequate. This report presents potential screening benchmarks for protection of aquatic life from contaminants in water. Because there is no guidance for screening benchmarks, a set of alternative benchmarks is presented herein. The alternative benchmarks are based on different conceptual approaches to estimating concentrations causing significant effects. For the upper screening benchmark, there are the acute National Ambient Water Quality Criteria (NAWQC) and the Secondary Acute Values (SAV). The SAV concentrations are values estimated with 80% confidence not to exceed the unknown acute NAWQC for those chemicals with no NAWQC. The alternative chronic benchmarks are the chronic NAWQC, the Secondary Chronic Value (SCV), the lowest chronic values for fish and daphnids, the lowest EC20 for fish and daphnids from chronic toxicity tests, the estimated EC20 for a sensitive species, and the concentration estimated to cause a 20% reduction in the recruit abundance of largemouth bass. It is recommended that ambient chemical concentrations be compared to all of these benchmarks. If NAWQC are exceeded, the chemicals must be contaminants of concern because the NAWQC are applicable or relevant and appropriate requirements (ARARs). If NAWQC are not exceeded, but other benchmarks are, contaminants should be selected on the basis of the number of benchmarks exceeded and the conservatism of the particular benchmark values, as discussed in the text. To the extent that toxicity data are available, this report presents the alternative benchmarks for chemicals that have been detected on the Oak Ridge Reservation. It also presents the data used to calculate the benchmarks and the sources of the data. It compares the benchmarks and discusses their relative conservatism and utility. This report supersedes a prior aquatic benchmarks report (Suter and Mabrey 1994). It adds two new types of benchmarks. It also updates the benchmark values where appropriate, adds some new benchmark values, replaces secondary sources with primary sources, and provides more complete documentation of the sources and derivation of all values.« less
William G. Luppold; William G. Luppold
1995-01-01
The quality of data concerning international hardwood products trade declined in the 1980s because of several problems associated with the collection and processing of individual export transaction records. This note examines the source, impact, and remedies for data problems caused by data screening procedures, nonreporting, recording errors, and alternative...
A Stochastic Spiking Neural Network for Virtual Screening.
Morro, A; Canals, V; Oliver, A; Alomar, M L; Galan-Prado, F; Ballester, P J; Rossello, J L
2018-04-01
Virtual screening (VS) has become a key computational tool in early drug design and screening performance is of high relevance due to the large volume of data that must be processed to identify molecules with the sought activity-related pattern. At the same time, the hardware implementations of spiking neural networks (SNNs) arise as an emerging computing technique that can be applied to parallelize processes that normally present a high cost in terms of computing time and power. Consequently, SNN represents an attractive alternative to perform time-consuming processing tasks, such as VS. In this brief, we present a smart stochastic spiking neural architecture that implements the ultrafast shape recognition (USR) algorithm achieving two order of magnitude of speed improvement with respect to USR software implementations. The neural system is implemented in hardware using field-programmable gate arrays allowing a highly parallelized USR implementation. The results show that, due to the high parallelization of the system, millions of compounds can be checked in reasonable times. From these results, we can state that the proposed architecture arises as a feasible methodology to efficiently enhance time-consuming data-mining processes such as 3-D molecular similarity search.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert Boehlecke
2004-04-01
The six bunkers included in CAU 204 were primarily used to monitor atmospheric testing or store munitions. The ''Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 204: Storage Bunkers, Nevada Test Site, Nevada'' (NNSA/NV, 2002a) provides information relating to the history, planning, and scope of the investigation; therefore, it will not be repeated in this CADD. This CADD identifies potential corrective action alternatives and provides a rationale for the selection of a recommended corrective action alternative for each CAS within CAU 204. The evaluation of corrective action alternatives is based on process knowledge and the results of investigative activitiesmore » conducted in accordance with the CAIP (NNSA/NV, 2002a) that was approved prior to the start of the Corrective Action Investigation (CAI). Record of Technical Change (ROTC) No. 1 to the CAIP (approval pending) documents changes to the preliminary action levels (PALs) agreed to by the Nevada Division of Environmental Protection (NDEP) and DOE, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). This ROTC specifically discusses the radiological PALs and their application to the findings of the CAU 204 corrective action investigation. The scope of this CADD consists of the following: (1) Develop corrective action objectives; (2) Identify corrective action alternative screening criteria; (3) Develop corrective action alternatives; (4) Perform detailed and comparative evaluations of corrective action alternatives in relation to corrective action objectives and screening criteria; and (5) Recommend and justify a preferred corrective action alternative for each CAS within CAU 204.« less
Digital retinal imaging in a residency-based patient-centered medical home.
Newman, Robert; Cummings, Doyle M; Doherty, Lisa; Patel, Nick R
2012-03-01
Diabetic retinopathy is the leading cause of blindness in adults in the United States, and early screening/treatment may preserve vision. This study examined the feasibility of using non-mydriatic digital retinal imaging (DRI) for retinopathy screening in a busy family medicine residency program at the point of care using a nurse-driven protocol. We compared the number of diabetics screened during a 1-year period before and after DRI protocol implementation. We also determined the prevalence of retinopathy, assessed patient satisfaction with the alternative screening process, and tracked ophthalmologic appointment compliance for patients referred because of abnormal screening results. Screening approximately doubled from 161 patients/year before the protocol to 330 patients/year after protocol implementation. However, DRI screening had no impact on ophthalmologic appointment compliance; only 58% of 153 patients referred for ophthalmologic evaluation because of positive screening findings completed their referral appointment. Seven cases needing urgent ophthalmologic treatment were identified. Satisfaction with primary care retinopathy screening was high. Use of a nurse-driven protocol for digital retinal imaging at the point of care dramatically improves rates of annual retinopathy screening in academic family medicine practice and can identify patients who require subspecialty referral. However, DRI screening does not improve visit compliance rates with ophthalmologists for evaluation and management.
American Cancer Society lung cancer screening guidelines.
Wender, Richard; Fontham, Elizabeth T H; Barrera, Ermilo; Colditz, Graham A; Church, Timothy R; Ettinger, David S; Etzioni, Ruth; Flowers, Christopher R; Gazelle, G Scott; Kelsey, Douglas K; LaMonte, Samuel J; Michaelson, James S; Oeffinger, Kevin C; Shih, Ya-Chen Tina; Sullivan, Daniel C; Travis, William; Walter, Louise; Wolf, Andrew M D; Brawley, Otis W; Smith, Robert A
2013-01-01
Findings from the National Cancer Institute's National Lung Screening Trial established that lung cancer mortality in specific high-risk groups can be reduced by annual screening with low-dose computed tomography. These findings indicate that the adoption of lung cancer screening could save many lives. Based on the results of the National Lung Screening Trial, the American Cancer Society is issuing an initial guideline for lung cancer screening. This guideline recommends that clinicians with access to high-volume, high-quality lung cancer screening and treatment centers should initiate a discussion about screening with apparently healthy patients aged 55 years to 74 years who have at least a 30-pack-year smoking history and who currently smoke or have quit within the past 15 years. A process of informed and shared decision-making with a clinician related to the potential benefits, limitations, and harms associated with screening for lung cancer with low-dose computed tomography should occur before any decision is made to initiate lung cancer screening. Smoking cessation counseling remains a high priority for clinical attention in discussions with current smokers, who should be informed of their continuing risk of lung cancer. Screening should not be viewed as an alternative to smoking cessation. Copyright © 2013 American Cancer Society, Inc.
Cost-effectiveness analysis of mammography and clinical breast examination strategies
Ahern, Charlotte Hsieh; Shen, Yu
2009-01-01
Purpose Breast cancer screening by mammography and clinical breast exam are commonly used for early tumor detection. Previous cost-effectiveness studies considered mammography alone or did not account for all relevant costs. In this study, we assessed the cost-effectiveness of screening schedules recommended by three major cancer organizations and compared them with alternative strategies. We considered costs of screening examinations, subsequent work-up, biopsy, and treatment interventions after diagnosis. Methods We used a microsimulation model to generate women’s life histories, and assessed screening and treatment impacts on survival. Using statistical models, we accounted for age-specific incidence, preclinical disease duration, and age-specific sensitivity and specificity for each screening modality. The outcomes of interest were quality-adjusted life years (QALYs) saved and total costs with a 3% annual discount rate. Incremental cost-effectiveness ratios were used to compare strategies. Sensitivity analyses were performed by varying some of the assumptions. Results Compared to guidelines from the National Cancer Institute and the U.S. Preventive Services Task Force, alternative strategies were more efficient. Mammography and clinical breast exam in alternating years from ages 40 to 79 was a cost-effective alternative compared to the guidelines, costing $35,500 per QALY saved compared with no screening. The American Cancer Society guideline was the most effective and the most expensive, costing over $680,000 for an added QALY compared to the above alternative. Conclusion Screening strategies with lower costs and benefits comparable to those currently recommended should be considered for implementation in practice and for future guidelines. PMID:19258473
Feng, Qianmei
2007-10-01
Federal law mandates that every checked bag at all commercial airports be screened by explosive detection systems (EDS), explosive trace detection systems (ETD), or alternative technologies. These technologies serve as critical components of airport security systems that strive to reduce security risks at both national and global levels. To improve the operational efficiency and airport security, emerging image-based technologies have been developed, such as dual-energy X-ray (DX), backscatter X-ray (BX), and multiview tomography (MVT). These technologies differ widely in purchasing cost, maintenance cost, operating cost, processing rate, and accuracy. Based on a mathematical framework that takes into account all these factors, this article investigates two critical issues for operating screening devices: setting specifications for continuous security responses by different technologies; and selecting technology or combination of technologies for efficient 100% baggage screening. For continuous security responses, specifications or thresholds are used for classifying threat items from nonthreat items. By investigating the setting of specifications on system security responses, this article assesses the risk and cost effectiveness of various technologies for both single-device and two-device systems. The findings provide the best selection of image-based technologies for both single-device and two-device systems. Our study suggests that two-device systems outperform single-device systems in terms of both cost effectiveness and accuracy. The model can be readily extended to evaluate risk and cost effectiveness of multiple-device systems for airport checked-baggage security screening.
Lam, Carl W; Lim, Seong-Rin; Schoenung, Julie M
2011-05-15
Modern manufacturing of printed wiring boards (PWBs) involves extensive use of various hazardous chemicals in different manufacturing steps such as board preparation, circuit design transfer, etching and plating processes. Two complementary environmental screening methods developed by the U.S. EPA, namely: (i) the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI) and (ii) Risk-Screening Environmental Indicators (RSEI), are used to quantify geographic and chemical environmental impacts in the U.S. PWB manufacturing industry based on Toxics Release Inventory (TRI) data. Although the release weight percentages of industrial chemicals such as methanol, glycol ethers and dimethylformamide comprise the larger fraction of reported air and water emissions, results indicate that lead, copper and their compounds' releases correspond to the highest environmental impact from toxicity potentials and risk-screening scores. Combining these results with further knowledge of PWB manufacturing, select alternative chemical processes and materials for pollution prevention are discussed. Examples of effective pollution prevention options in the PWB industry include spent etchant recovery technologies, and process and material substitutions. In addition, geographic assessment of environmental burden highlights states where promotion of pollution prevention strategies and emissions regulations can have the greatest effect to curb the PWB industry's toxic release impacts. Copyright © 2011 Elsevier B.V. All rights reserved.
Cell and small animal models for phenotypic drug discovery.
Szabo, Mihaly; Svensson Akusjärvi, Sara; Saxena, Ankur; Liu, Jianping; Chandrasekar, Gayathri; Kitambi, Satish S
2017-01-01
The phenotype-based drug discovery (PDD) approach is re-emerging as an alternative platform for drug discovery. This review provides an overview of the various model systems and technical advances in imaging and image analyses that strengthen the PDD platform. In PDD screens, compounds of therapeutic value are identified based on the phenotypic perturbations produced irrespective of target(s) or mechanism of action. In this article, examples of phenotypic changes that can be detected and quantified with relative ease in a cell-based setup are discussed. In addition, a higher order of PDD screening setup using small animal models is also explored. As PDD screens integrate physiology and multiple signaling mechanisms during the screening process, the identified hits have higher biomedical applicability. Taken together, this review highlights the advantages gained by adopting a PDD approach in drug discovery. Such a PDD platform can complement target-based systems that are currently in practice to accelerate drug discovery.
Recovery and purification process development for monoclonal antibody production
Ma, Junfen; Winter, Charles; Bayer, Robert
2010-01-01
Hundreds of therapeutic monoclonal antibodies (mAbs) are currently in development, and many companies have multiple antibodies in their pipelines. Current methodology used in recovery processes for these molecules are reviewed here. Basic unit operations such as harvest, Protein A affinity chromatography and additional polishing steps are surveyed. Alternative processes such as flocculation, precipitation and membrane chromatography are discussed. We also cover platform approaches to purification methods development, use of high throughput screening methods, and offer a view on future developments in purification methodology as applied to mAbs. PMID:20647768
Ritvo, Paul; Myers, Ronald E; Serenity, Mardie; Gupta, Samir; Inadomi, John M; Green, Beverly B; Jerant, Anthony; Tinmouth, Jill; Paszat, Lawrence; Pirbaglou, Meysam; Rabeneck, Linda
2017-08-01
To derive a taxonomy for colorectal cancer screening that advances Randomized Controlled Trials (RCTs) and screening uptake. Detailed publication review, multiple interviews with principal investigators (PIs) and collaboration with PIs as co-authors produced a CRCS intervention taxonomy. Semi-structured interview questions with PIs (Drs. Inadomi, Myers, Green, Gupta, Jerant and Ritvo) yielded details about trial conduct. Interview comparisons led to an iterative process informing serial interviews until a consensus was obtained on final taxonomy structure. These taxonomy headings (Engagement Sponsor, Population Targeted, Alternative Screening Tests, Delivery Methods, and Support for Test Performance (EPADS)) were used to compare studies. Exemplary insights emphasized: 1) direct test delivery to patients; 2) linguistic-ethnic matching of staff to minority subjects; and 3) authorization of navigators to schedule or refer for colonoscopies and/or distribute stool blood tests during screening promotion. PIs of key RCTs (2012-2015) derived a CRCS taxonomy useful in detailed examination of CRCS promotion and design of future RCTs. Copyright © 2017 Elsevier Inc. All rights reserved.
Bell, Andrew S; Bradley, Joseph; Everett, Jeremy R; Loesel, Jens; McLoughlin, David; Mills, James; Peakman, Marie-Claire; Sharp, Robert E; Williams, Christine; Zhu, Hongyao
2016-11-01
High-throughput screening (HTS) is an effective method for lead and probe discovery that is widely used in industry and academia to identify novel chemical matter and to initiate the drug discovery process. However, HTS can be time consuming and costly and the use of subsets as an efficient alternative to screening entire compound collections has been investigated. Subsets may be selected on the basis of chemical diversity, molecular properties, biological activity diversity or biological target focus. Previously, we described a novel form of subset screening: plate-based diversity subset (PBDS) screening, in which the screening subset is constructed by plate selection (rather than individual compound cherry-picking), using algorithms that select for compound quality and chemical diversity on a plate basis. In this paper, we describe a second-generation approach to the construction of an updated subset: PBDS2, using both plate and individual compound selection, that has an improved coverage of the chemical space of the screening file, whilst only selecting the same number of plates for screening. We describe the validation of PBDS2 and its successful use in hit and lead discovery. PBDS2 screening became the default mode of singleton (one compound per well) HTS for lead discovery in Pfizer.
Print2Screen Mobile App: Embedding Multimedia in Printed ODL Course Materials Using QR Codes
ERIC Educational Resources Information Center
Abeywardena, Ishan Sudeera
2017-01-01
With the rise of OER and multimedia such as YouTube videos, many academic institutions are becoming mindful of the richness they bring into the teaching and learning process. Given that multimedia resources cannot be directly integrated into printed material, the only available alternative is to print hyperlinks, which teachers and learners can…
Fabrication of a wettability-gradient surface on copper by screen-printing techniques
NASA Astrophysics Data System (ADS)
Huang, Ding-Jun; Leu, Tzong-Shyng
2015-08-01
In this study, a screen-printing technique is utilized to fabricate a wettability-gradient surface on a copper substrate. The pattern definitions on the copper surface were freely fabricated to define the regions with different wettabilities, for which the printing definition technique was developed as an alternative to the existing costly photolithography techniques. This fabrication process using screen printing in tandem with chemical modification methods can easily realize an excellent wettability-gradient surface with superhydrophobicity and superhydrophilicity. Surface analyses were performed to characterize conditions in some fabrication steps. A water droplet movement sequence is provided to clearly demonstrate the droplet-driving effectiveness of the fabricated gradient surface. The droplet-driving efficiency offers a promising solution for condensation heat transfer applications in the foreseeable future.
Weidel, Elisabeth; Negri, Matthias; Empting, Martin; Hinsberger, Stefan; Hartmann, Rolf W
2014-01-01
In order to identify new scaffolds for drug discovery, surface plasmon resonance is frequently used to screen structurally diverse libraries. Usually, hit rates are low and identification processes are time consuming. Hence, approaches which improve hit rates and, thus, reduce the library size are required. In this work, we studied three often used strategies for their applicability to identify inhibitors of PqsD. In two of them, target-specific aspects like inhibition of a homologous protein or predicted binding determined by virtual screening were used for compound preselection. Finally, a fragment library, covering a large chemical space, was screened and served as comparison. Indeed, higher hit rates were observed for methods employing preselected libraries indicating that target-oriented compound selection provides a time-effective alternative.
Tribe, Candice; Webb, Janine
2012-01-01
Abstract Background Cervical cancer screening research has predominantly focused on one type of participation, namely compliance with medical recommendations, and has largely ignored other types of participation. While there is some research that has taken a different approach, findings in this research area are not well integrated under a theoretical framework. Objective The aim of this study is to show how consideration of a broader definition of participation and better integration of the theoretical conceptualization of participation in cervical cancer screening are both possible and desirable to enable a better understanding of women’s experiences of cervical cancer screening specifically and to improve women’s health generally. Main Conclusion It is suggested that alternative types of participation in cervical cancer screening warrant further investigation and that a social identity theoretical approach offers one way of integrating such conceptualizations of participation. The paper also argues for more explicit consideration of the role of social processes and of the variables, such as power, social identity and relational justice, which are involved in participation in cervical cancer screening. PMID:22646802
Wehage, Kristopher; Chenhansa, Panan; Schoenung, Julie M
2017-01-01
GreenScreen® for Safer Chemicals is a framework for comparative chemical hazard assessment. It is the first transparent, open and publicly accessible framework of its kind, allowing manufacturers and governmental agencies to make informed decisions about the chemicals and substances used in consumer products and buildings. In the GreenScreen® benchmarking process, chemical hazards are assessed and classified based on 18 hazard endpoints from up to 30 different sources. The result is a simple numerical benchmark score and accompanying assessment report that allows users to flag chemicals of concern and identify safer alternatives. Although the screening process is straightforward, aggregating and sorting hazard data is tedious, time-consuming, and prone to human error. In light of these challenges, the present work demonstrates the usage of automation to cull chemical hazard data from publicly available internet resources, assign metadata, and perform a GreenScreen® hazard assessment using the GreenScreen® "List Translator." The automated technique, written as a module in the Python programming language, generates GreenScreen® List Translation data for over 3000 chemicals in approximately 30 s. Discussion of the potential benefits and limitations of automated techniques is provided. By embedding the library into a web-based graphical user interface, the extensibility of the library is demonstrated. The accompanying source code is made available to the hazard assessment community. Integr Environ Assess Manag 2017;13:167-176. © 2016 SETAC. © 2016 SETAC.
Couturier, Jean‐Luc; Kokossis, Antonis; Dubois, Jean‐Luc
2016-01-01
Abstract Biorefineries offer a promising alternative to fossil‐based processing industries and have undergone rapid development in recent years. Limited financial resources and stringent company budgets necessitate quick capital estimation of pioneering biorefinery projects at the early stages of their conception to screen process alternatives, decide on project viability, and allocate resources to the most promising cases. Biorefineries are capital‐intensive projects that involve state‐of‐the‐art technologies for which there is no prior experience or sufficient historical data. This work reviews existing rapid cost estimation practices, which can be used by researchers with no previous cost estimating experience. It also comprises a comparative study of six cost methods on three well‐documented biorefinery processes to evaluate their accuracy and precision. The results illustrate discrepancies among the methods because their extrapolation on biorefinery data often violates inherent assumptions. This study recommends the most appropriate rapid cost methods and urges the development of an improved early‐stage capital cost estimation tool suitable for biorefinery processes. PMID:27484398
Interventions following hearing screening in adults: a systematic descriptive review.
Pronk, Marieke; Kramer, Sophia E; Davis, Adrian C; Stephens, Dafydd; Smith, Pauline A; Thodi, Chryssoula; Anteunis, Lucien J C; Parazzini, Marta; Grandori, Ferdinando
2011-09-01
Adult hearing screening may be a solution to the under-diagnosis and under-treatment of hearing loss in adults. Limited use and satisfaction with hearing aids indicate that consideration of alternative interventions following hearing screening may be needed. The primary aim of this study is to provide an overview of all intervention types that have been offered to adult (≥ 18 years) screen-failures. Systematic literature review. Articles were identified through systematic searches in PubMed, EMBASE, Cinahl, the Cochrane Library, private libraries, and through reference checking. Of the initial 3027 papers obtained from the searches, a total of 37 were found to be eligible. The great majority of the screening programmes (i.e. 26) referred screen-failures to a hearing specialist without further rehabilitation being specified. Most of the others (i.e. seven) led to the provision of hearing aids. Four studies offered alternative interventions comprising communication programme elements (e.g. speechreading, hearing tactics) or advice on environmental aids. Interventions following hearing screening generally comprised referral to a hearing specialist or hearing aid rehabilitation. Some programmes offered alternative rehabilitation options. These may be valuable as an addition to or replacement of hearing aid rehabilitation. It is recommended that this be addressed in future research.
An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.
ERIC Educational Resources Information Center
Square, Regina; And Others
1985-01-01
A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!
The report gives results of a screening evaluation of volatile organic emissions from printed circuit board laminates and potential pollution prevention alternatives. In the evaluation, printed circuit board laminates, without circuitry, commonly found in personal computer (PC) m...
Developmental neurotoxicity testing (DNT) is perceived by many stakeholders to be an area in critical need of alternative methods to current animal testing protocols and gUidelines. An immediate goal is to develop test methods that are capable of screening large numbers of chemic...
National Environmental Policy Act Hazards Assessment for the TREAT Alternative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd D. Christensen; Annette L. Schafer
2013-11-01
This document provides an assessment of hazards as required by the National Environmental Policy Act for the alternative of restarting the reactor at the Transient Reactor Test (TREAT) facility by the Resumption of Transient Testing Program. Potential hazards have been identified and screening level calculations have been conducted to provide estimates of unmitigated dose consequences that could be incurred through this alternative. Consequences considered include those related to use of the TREAT Reactor, experiment assembly handling, and combined events involving both the reactor and experiments. In addition, potential safety structures, systems, and components for processes associated with operating TREAT andmore » onsite handling of nuclear fuels and experiments are listed. If this alternative is selected, a safety basis will be prepared in accordance with 10 CFR 830, “Nuclear Safety Management,” Subpart B, “Safety Basis Requirements.”« less
National Environmental Policy Act Hazards Assessment for the TREAT Alternative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christensen, Boyd D.; Schafer, Annette L.
2014-02-01
This document provides an assessment of hazards as required by the National Environmental Policy Act for the alternative of restarting the reactor at the Transient Reactor Test (TREAT) facility by the Resumption of Transient Testing Program. Potential hazards have been identified and screening level calculations have been conducted to provide estimates of unmitigated dose consequences that could be incurred through this alternative. Consequences considered include those related to use of the TREAT Reactor, experiment assembly handling, and combined events involving both the reactor and experiments. In addition, potential safety structures, systems, and components for processes associated with operating TREAT andmore » onsite handling of nuclear fuels and experiments are listed. If this alternative is selected, a safety basis will be prepared in accordance with 10 CFR 830, “Nuclear Safety Management,” Subpart B, “Safety Basis Requirements.”« less
Thinking Style as a Predictor of Men’s Participation in Cancer Screening
McGuiness, Clare E.; Turnbull, Deborah; Wilson, Carlene; Duncan, Amy; Flight, Ingrid H.; Zajac, Ian
2016-01-01
Men’s participation in cancer screening may be influenced by their thinking style. Men’s need for cognition (NFC) and faith in intuition were measured to explore whether they varied by demographic variables or predicted screening behavior. Australian males (n = 585, aged 50-74 years) completed surveys about past screening and were subsequently offered mailed fecal occult blood tests (FOBTs). Demographic predictors included age, socioeconomic status, educational attainment, and language spoken at home. The screening behaviors were self-reported prostate cancer screening (prostate-specific antigen testing and digital rectal examinations [DREs]), and colorectal cancer screening (self-reported FOBT participation and recorded uptake of the FOBT offer). Analysis comprised principal component analysis and structural equation modelling. NFC was positively related to demographic variables education, socioeconomic status, and speaking English at home. Faith in intuition was negatively related to educational attainment. NFC predicted variance in self-reported DRE participation (r = .11, p = .016). No other relationships with thinking style were statistically significant. The relationship of NFC to DRE participation may reflect the way certain attributes of this screening method are processed, or alternatively, it may reflect willingness to report participation. The relationship of thinking style to a range of healthy behaviors should be further explored. PMID:27923966
Stickie removal using neutral enzymatic repulping pressure screening
Marguerite Sykes; John Klungness; Roland Gleisner; Said Abubakr
1998-01-01
Removal of stickie contaminants is currently a major focus of paper recycling research. Medium consistency alkaline repulping followed by pressure screening has proven to be effective for stickie removal. There is, however, an alternate method that is equally effective and more environmentally benign. This study compares the effectiveness of this alternative method,...
Alternative Affinity Ligands for Immunoglobulins.
Kruljec, Nika; Bratkovič, Tomaž
2017-08-16
The demand for recombinant therapeutic antibodies and Fc-fusion proteins is expected to increase in the years to come. Hence, extensive efforts are concentrated on improving the downstream processing. In particular, the development of better-affinity chromatography matrices, supporting robust time- and cost-effective antibody purification, is warranted. With the advances in molecular design and high-throughput screening approaches from chemical and biological combinatorial libraries, novel affinity ligands representing alternatives to bacterial immunoglobulin (Ig)-binding proteins have entered the scene. Here, we review the design, development, and properties of diverse classes of alternative antibody-binding ligands, ranging from engineered versions of Ig-binding proteins, to artificial binding proteins, peptides, aptamers, and synthetic small-molecular-weight compounds. We also provide examples of applications for the novel affinity matrices in chromatography and beyond.
NASA Astrophysics Data System (ADS)
Lau, Wan F.; Withka, Jane M.; Hepworth, David; Magee, Thomas V.; Du, Yuhua J.; Bakken, Gregory A.; Miller, Michael D.; Hendsch, Zachary S.; Thanabal, Venkataraman; Kolodziej, Steve A.; Xing, Li; Hu, Qiyue; Narasimhan, Lakshmi S.; Love, Robert; Charlton, Maura E.; Hughes, Samantha; van Hoorn, Willem P.; Mills, James E.
2011-07-01
Fragment Based Drug Discovery (FBDD) continues to advance as an efficient and alternative screening paradigm for the identification and optimization of novel chemical matter. To enable FBDD across a wide range of pharmaceutical targets, a fragment screening library is required to be chemically diverse and synthetically expandable to enable critical decision making for chemical follow-up and assessing new target druggability. In this manuscript, the Pfizer fragment library design strategy which utilized multiple and orthogonal metrics to incorporate structure, pharmacophore and pharmacological space diversity is described. Appropriate measures of molecular complexity were also employed to maximize the probability of detection of fragment hits using a variety of biophysical and biochemical screening methods. In addition, structural integrity, purity, solubility, fragment and analog availability as well as cost were important considerations in the selection process. Preliminary analysis of primary screening results for 13 targets using NMR Saturation Transfer Difference (STD) indicates the identification of uM-mM hits and the uniqueness of hits at weak binding affinities for these targets.
Lau, Wan F; Withka, Jane M; Hepworth, David; Magee, Thomas V; Du, Yuhua J; Bakken, Gregory A; Miller, Michael D; Hendsch, Zachary S; Thanabal, Venkataraman; Kolodziej, Steve A; Xing, Li; Hu, Qiyue; Narasimhan, Lakshmi S; Love, Robert; Charlton, Maura E; Hughes, Samantha; van Hoorn, Willem P; Mills, James E
2011-07-01
Fragment Based Drug Discovery (FBDD) continues to advance as an efficient and alternative screening paradigm for the identification and optimization of novel chemical matter. To enable FBDD across a wide range of pharmaceutical targets, a fragment screening library is required to be chemically diverse and synthetically expandable to enable critical decision making for chemical follow-up and assessing new target druggability. In this manuscript, the Pfizer fragment library design strategy which utilized multiple and orthogonal metrics to incorporate structure, pharmacophore and pharmacological space diversity is described. Appropriate measures of molecular complexity were also employed to maximize the probability of detection of fragment hits using a variety of biophysical and biochemical screening methods. In addition, structural integrity, purity, solubility, fragment and analog availability as well as cost were important considerations in the selection process. Preliminary analysis of primary screening results for 13 targets using NMR Saturation Transfer Difference (STD) indicates the identification of uM-mM hits and the uniqueness of hits at weak binding affinities for these targets.
Importance of perspective in economic analyses of cancer screening decisions.
Mansley, E C; McKenna, M T
2001-10-06
As the fifth, and final, report in this Lancet series on health economics, we discuss how economic analyses in public health, with cancer screening as the example, differ depending on the perspective taken. We identify nine different, but related, decision makers at various levels, from the individual patient to society as a whole, and discuss how their different viewpoints affect their ultimate decisions. Central to our discussion is the identification of seven distinct components of perspective, each potentially important in the screening decision. In many fields of healthcare, decisions about the use of resources, such as time, wealth, or energy, are made by weighing up the positive and negative consequences of the alternatives under consideration and are thus based on an economic analysis of the situation (although sometimes this process is subconscious). For simplicity, we restrict our report to the effect of perspective on cancer screening decisions and show how the costs (negative consequences) and benefits (positive consequences) vary depending on the decision maker.
Rapid screening and species identification of E. coli, Listeria, and Salmonella by SERS technique
NASA Astrophysics Data System (ADS)
Liu, Yongliang; Chao, Kuanglin; Kim, Moon S.; Nou, Xiangwu
2008-04-01
Techniques for routine and rapid screening of the presence of foodborne bacteria are needed, and this study reports the feasibility of citrate-reduced silver colloidal SERS for identifying E. coli, Listeria, and Salmonella. Relative standard deviation (RSD) of SERS spectra from silver colloidal suspensions and ratios of P-O SERS peaks from small molecule (K3PO4) were used to assess the reproducibility, stability, and binding effectiveness of citrate-reduced silver colloids over batch and storage process. The results suggested the reproducibility of silver colloids over batch process and also stability and consistent binding effectiveness over 60-day storage period. Notably, although silver colloidal nanoparticles were stable for at least 90 days, their binding effectiveness began to decrease slightly after 60-day storage, with a binding reduction of about 12% at 90th day. Colloidal silver SERS, as demonstrated here, could be an important alternative technique in the rapid and simultaneous screening of the presence of three most outbreak bacteria due to the exclusive biomarkers, label-free and easy sampling attribute.
Spotlight on Fluorescent Biosensors—Tools for Diagnostics and Drug Discovery
2013-01-01
Fluorescent biosensors constitute potent tools for probing biomolecules in their natural environment and for visualizing dynamic processes in complex biological samples, living cells, and organisms. They are well suited for highlighting molecular alterations associated with pathological disorders, thereby offering means of implementing sensitive and alternative technologies for diagnostic purposes. They constitute attractive tools for drug discovery programs, from high throughput screening assays to preclinical studies. PMID:24900780
Using skype as an alternative for residency selection interviews.
Edje, Louito; Miller, Christine; Kiefer, Jacklyn; Oram, David
2013-09-01
Residency interviews can place significant time and financial burdens on applicants. To determine whether the use of Skype as a screening tool during interview season in a family medicine residency is cost-effective and time-efficient for the applicant and the residency program. We surveyed 2 groups of medical students during interviews for our family medicine program. Thirty-two students were interviewed via our face-to-face, traditional interview (TI) process, and 10 students, the second group, who did not meet the program's standard interview selection criteria for TI, underwent our Skype interview (SI) process. Using an unpaired t test, we found that the applicants' costs of an SI were significantly less than a TI, $566 (95% confidence interval [CI] $784-$349, P < .001). Direct cash savings plus indirect salary savings to the program were $5,864, with a time savings of 7 interview days. Three of the applicants who were participants in the SI limb of the study were in our final rank order list. For interviewing in family medicine residencies, use of Skype may be a cost-effective and time-efficient screening tool for both the applicant and the program. Alternate uses of SI may include the time-sensitive, postmatch Supplemental Offer and Acceptance Program.
Using Skype as an Alternative for Residency Selection Interviews
Edje, Louito; Miller, Christine; Kiefer, Jacklyn; Oram, David
2013-01-01
Background Residency interviews can place significant time and financial burdens on applicants. Objective To determine whether the use of Skype as a screening tool during interview season in a family medicine residency is cost-effective and time-efficient for the applicant and the residency program. Methods We surveyed 2 groups of medical students during interviews for our family medicine program. Thirty-two students were interviewed via our face-to-face, traditional interview (TI) process, and 10 students, the second group, who did not meet the program's standard interview selection criteria for TI, underwent our Skype interview (SI) process. Results Using an unpaired t test, we found that the applicants' costs of an SI were significantly less than a TI, $566 (95% confidence interval [CI] $784–$349, P < .001). Direct cash savings plus indirect salary savings to the program were $5,864, with a time savings of 7 interview days. Three of the applicants who were participants in the SI limb of the study were in our final rank order list. Conclusions For interviewing in family medicine residencies, use of Skype may be a cost-effective and time-efficient screening tool for both the applicant and the program. Alternate uses of SI may include the time-sensitive, postmatch Supplemental Offer and Acceptance Program. PMID:24404318
Thomas, Duncan C
2017-07-01
Screening behavior depends on previous screening history and family members' behaviors, which can act as both confounders and intermediate variables on a causal pathway from screening to disease risk. Conventional analyses that adjust for these variables can lead to incorrect inferences about the causal effect of screening if high-risk individuals are more likely to be screened. Analyzing the data in a manner that treats screening as randomized conditional on covariates allows causal parameters to be estimated; inverse probability weighting based on propensity of exposure scores is one such method considered here. I simulated family data under plausible models for the underlying disease process and for screening behavior to assess the performance of alternative methods of analysis and whether a targeted screening approach based on individuals' risk factors would lead to a greater reduction in cancer incidence in the population than a uniform screening policy. Simulation results indicate that there can be a substantial underestimation of the effect of screening on subsequent cancer risk when using conventional analysis approaches, which is avoided by using inverse probability weighting. A large case-control study of colonoscopy and colorectal cancer from Germany shows a strong protective effect of screening, but inverse probability weighting makes this effect even stronger. Targeted screening approaches based on either fixed risk factors or family history yield somewhat greater reductions in cancer incidence with fewer screens needed to prevent one cancer than population-wide approaches, but the differences may not be large enough to justify the additional effort required. See video abstract at, http://links.lww.com/EDE/B207.
Tsagkari, Mirela; Couturier, Jean-Luc; Kokossis, Antonis; Dubois, Jean-Luc
2016-09-08
Biorefineries offer a promising alternative to fossil-based processing industries and have undergone rapid development in recent years. Limited financial resources and stringent company budgets necessitate quick capital estimation of pioneering biorefinery projects at the early stages of their conception to screen process alternatives, decide on project viability, and allocate resources to the most promising cases. Biorefineries are capital-intensive projects that involve state-of-the-art technologies for which there is no prior experience or sufficient historical data. This work reviews existing rapid cost estimation practices, which can be used by researchers with no previous cost estimating experience. It also comprises a comparative study of six cost methods on three well-documented biorefinery processes to evaluate their accuracy and precision. The results illustrate discrepancies among the methods because their extrapolation on biorefinery data often violates inherent assumptions. This study recommends the most appropriate rapid cost methods and urges the development of an improved early-stage capital cost estimation tool suitable for biorefinery processes. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.
Brisset, Hugues; Briand, Jean-François; Barry-Martinet, Raphaëlle; Duong, The Hy; Frère, Pierre; Gohier, Frédéric; Leriche, Philippe; Bressy, Christine
2018-04-17
Several alternatives are currently investigated to prevent and control the natural process of colonization of any seawater submerged surfaces by marine organisms. Since few years we develop an approach based on addressable electroactive coatings containing conducting polymers or polymers with lateral redox groups. In this article we describe the use of a screen-printed plate formed by 96 three-electrode electrochemical cells to assess the potential of these electroactive coatings to prevent the adhesion of marine bacteria. This novel platform is intended to control and record the redox properties of the electroactive coating in each well during the bioassay (15 h) and to allow screening its antiadhesion activity with enough replicates to support significant conclusions. Validation of this platform was carried out with poly(ethylenedioxythiophene) (PEDOT) as electroactive coating obtained by electropolymerization of EDOT monomer in artificial seawater electrolyte on the working electrode of each electrochemical cell of the 96-well microplate.
Classification of human pathogen bacteria for early screening using electronic nose
NASA Astrophysics Data System (ADS)
Zulkifli, Syahida Amani; Mohamad, Che Wan Syarifah Robiah; Abdullah, Abu Hassan
2017-10-01
This paper present human pathogen bacteria for early screening using electronic nose. Electronic nose (E-nose) known as gas sensor array is a device that analyze the odor measurement give the fast response and less time consuming for clinical diagnosis. Many bacterial pathogens could lead to life threatening infections. Accurate and rapid diagnosis is crucial for the successful management of these infections disease. The conventional method need more time to detect the growth of bacterial. Alternatively, the bacteria are Pseudomonas aeruginosa and Shigella cultured on different media agar can be detected and classifies according to the volatile compound in shorter time using electronic nose (E-nose). Then, the data from electronic nose (E-nose) is processed using statistical method which is principal component analysis (PCA). The study shows the capability of electronic nose (E-nose) for early screening for bacterial infection in human stomach.
Considerations for designing chemical screening strategies in plant biology
Serrano, Mario; Kombrink, Erich; Meesters, Christian
2015-01-01
Traditionally, biologists regularly used classical genetic approaches to characterize and dissect plant processes. However, this strategy is often impaired by redundancy, lethality or pleiotropy of gene functions, which prevent the isolation of viable mutants. The chemical genetic approach has been recognized as an alternative experimental strategy, which has the potential to circumvent these problems. It relies on the capacity of small molecules to modify biological processes by specific binding to protein target(s), thereby conditionally modifying protein function(s), which phenotypically resemble mutation(s) of the encoding gene(s). A successful chemical screening campaign comprises three equally important elements: (1) a reliable, robust, and quantitative bioassay, which allows to distinguish between potent and less potent compounds, (2) a rigorous validation process for candidate compounds to establish their selectivity, and (3) an experimental strategy for elucidating a compound's mode of action and molecular target. In this review we will discuss details of this general strategy and additional aspects that deserve consideration in order to take full advantage of the power provided by the chemical approach to plant biology. In addition, we will highlight some success stories of recent chemical screenings in plant systems, which may serve as teaching examples for the implementation of future chemical biology projects. PMID:25904921
Context-dependent effects of background colour in free recall with spatially grouped words.
Sakai, Tetsuya; Isarida, Toshiko K; Isarida, Takeo
2010-10-01
Three experiments investigated context-dependent effects of background colour in free recall with groups of items. Undergraduates (N=113) intentionally studied 24 words presented in blocks of 6 on a computer screen with two different background colours. The two background colours were changed screen-by-screen randomly (random condition) or alternately (alternation condition) during the study period. A 30-second filled retention interval was imposed before an oral free-recall test. A signal for free recall was presented throughout the test on one of the colour background screens presented at study. Recalled words were classified as same- or different-context words according to whether the background colours at study and test were the same or different. The random condition produced significant context-dependent effects, whereas the alternation condition showed no context-dependent effects, regardless of whether the words were presented once or twice. Furthermore, the words presented on the same screen were clustered in recall, whereas the words presented against the same background colour but on different screens were not clustered. The present results imply: (1) background colours can cue spatially massed words; (2) background colours act as temporally local context; and (3) predictability of the next background colour modulates the context-dependent effect.
Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen.
Bamford, J; Fortnum, H; Bristow, K; Smith, J; Vamvakas, G; Davies, L; Taylor, R; Watkin, P; Fonseca, S; Davis, A; Hind, S
2007-08-01
To describe and analyse in detail current practice of school entry hearing screening (SES) in the UK. Main electronic databases were searched up to May 2005. A national postal questionnaire survey was addressed to all leads for SES in the UK, considering current practice in terms of implementation, protocols, target population and performance data. Primary data from cohort studies in one area of London were examined. A systematic review of alternative SES tests, test performance and impact on outcomes was carried out. Finally, a review of published studies on costs, plus economic modelling of current and alternative programmes was prepared. The survey suggested that SES is used in most of England, Wales and Scotland; just over 10% of respondents have abandoned the screen; others are awaiting national guidance. Coverage of SES is variable, but is often over 90% for children in state schools. Referral rates are variable, with a median of about 8%. The test used for the screen is the pure tone sweep test but with wide variation in implementation, with differing frequencies, pass criteria and retest protocols; written examples of protocols were often poor and ambiguous. There is no national approach to data collection, audit and quality assurance, and there are variable approaches at local level. The screen is performed in less than ideal test conditions and resources are often limited, which has an impact on the quality of the screen. The primary cohort studies show that the prevalence of permanent childhood hearing loss continues to increase through infancy. Of the 3.47 in 1000 children with a permanent hearing loss at school screen age, 1.89 in 1000 required identification after the newborn screen. Newborn hearing screening is likely to reduce significantly the yield of SES for permanent bilateral and unilateral hearing impairments; yield had fallen from about 1.11 in 1000 before newborn screening to about 0.34 in 1000 for cohorts that had had newborn screening, of which only 0.07 in 1000 were unilateral impairments. Just under 20% of permanent moderate or greater bilateral, mild bilateral and unilateral impairments, known to services as 6-year-olds or older, remained to be identified around the time of school entry. No good-quality published comparative trials of alternative screens or tests for SES were identified and studies concerned with the relative accuracy of alternative tests are difficult to compare and often flawed by differing referral criteria and case definitions; with full pure tone audiometry as the reference test, the pure tone sweep test appears to have high sensitivity and high specificity for minimal, mild and greater hearing impairments, better than alternative tests for which evidence was identified. There is insufficient evidence regarding possible harm of the screen. There were no published studies identified that examined the possible effects of SES on longer term outcomes. No good-quality published economic evaluations of SES were identified and a universal SES based on pure tone sweep tests was associated with higher costs and slightly higher quality-adjusted life-years (QALYs) compared with no screen and other screen alternatives; the incremental cost-effectiveness ratio for such a screen is around 2500 pounds per QALY gained; the range of expected costs, QALYs and net benefits was broad, indicating a considerable degree of uncertainty. Targeted screening could be more cost-effective than universal school entry screening; however, the lack of primary data and the wide limits for variables in the modelling mean that any conclusions must be considered indicative and exploratory only. A national screening programme for permanent hearing impairment at school entry meets all but three of the criteria for a screening programme, but at least six criteria are not met for screening for temporary hearing impairment. The lack of good-quality evidence in this area remains a serious problem. Services should improve quality and audit screen performance for identification of previously unknown permanent hearing impairment, pending evidence-based policy decisions based on the research recommendations. Further research is needed into a number of important areas including the evaluation of an agreed national protocol for services delivering SES to make future studies and audits of screen performance more directly comparable.
NASA Astrophysics Data System (ADS)
Hendhratmoyo, Andri; Syafi'i; Pungky Pramesti, Florentina
2017-11-01
Due to the limited budget of urban roads maintenance and rehabilitation, its prioritizationis inevitable. Many models have been developed to solve these problems. That is the reason why the purpose of this study was to evaluate the screening process in the decision making of the urban roads maintenance and rehabilitation priority. The prioritization that have to be taken into account on the effect of important criteria are road condition, traffic volume, budget processing and land use. 30 stakeholders were asked to fill in the questionnaires. The object of this case study are 188 urban roads sections at Ponorogo in order to examine the priorities. The researchers collected the data from Surface Distress Index (SDI), traffic volume, budget processing and land use of these road sections. Based on analysis, the weights of the criteria were: road condition (W1) = 0,411; traffic volume (W2) = 0,122; budget processing (W3) = 0,363 and land use (W4) = 0,105. The result of this study by the comparison of the index values of the alternatives priorities, Nyi Ageng Serang Street, was revealed to have the highest priority over the other streets regarding of maintenance and rehabilitation activities.
Cost-effectiveness of organized versus opportunistic cervical cytology screening in Hong Kong.
Kim, Jane J; Leung, Gabriel M; Woo, Pauline P S; Goldie, Sue J
2004-06-01
To assess the cost-effectiveness of alternative cervical cancer screening strategies to inform the design and implementation of a government-sponsored population-based screening programme in Hong Kong. Cost-effectiveness analysis using a computer-based model of cervical carcinogenesis was performed. Strategies included no screening, opportunistic screening (status quo), organized screening using either conventional or liquid-based cytology conducted at different frequencies. The main outcome measures were cancer incidence reduction, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios. Data were from local hospitals and laboratories, clinical trials, prospective studies and other published literature. Compared with no screening, a simulation of the current situation of opportunistic screening using cervical cytology produced a nearly 40 per cent reduction in the lifetime risk of cervical cancer. However, with organized screening every 3, 4 and 5 years, corresponding reductions with conventional (and liquid-based) cytology were 90.4 (92.9), 86.8 (90.2) and 83.2 per cent (87.3 per cent) compared with no screening. For all cytology-based screening strategies, opportunistic screening was more costly and less effective than an organized programme of screening every 3, 4 and 5 years. Every 3-, 4- and 5-year screening cost $12,300, $7100 and $800 per YLS, each compared with the next best alternative. Compared with the status quo of opportunistic screening, adopting a policy of organized, mass cervical screening in Hong Kong can substantially increase benefits and reduce costs.
Comparison of Alternate and Original Items on the Montreal Cognitive Assessment.
Lebedeva, Elena; Huang, Mei; Koski, Lisa
2016-03-01
The Montreal Cognitive Assessment (MoCA) is a screening tool for mild cognitive impairment (MCI) in elderly individuals. We hypothesized that measurement error when using the new alternate MoCA versions to monitor change over time could be related to the use of items that are not of comparable difficulty to their corresponding originals of similar content. The objective of this study was to compare the difficulty of the alternate MoCA items to the original ones. Five selected items from alternate versions of the MoCA were included with items from the original MoCA administered adaptively to geriatric outpatients (N = 78). Rasch analysis was used to estimate the difficulty level of the items. None of the five items from the alternate versions matched the difficulty level of their corresponding original items. This study demonstrates the potential benefits of a Rasch analysis-based approach for selecting items during the process of development of parallel forms. The results suggest that better match of the items from different MoCA forms by their difficulty would result in higher sensitivity to changes in cognitive function over time.
ERIC Educational Resources Information Center
Salerno, Jennifer; Darling-Fisher, Cindy; Hawkins, Nicole M.; Fraker, Elizabeth
2013-01-01
Background: This article describes a school-wide sexually transmitted infection (STI) screening to identify adolescent high-risk sexual behaviors, STI history/incidence, and presence of chlamydia and gonorrhea, and examines relationships between high-risk behaviors and screening positive for chlamydia and gonorrhea in an alternative high school…
Sun, Guanghao; Nakayama, Yosuke; Dagdanpurev, Sumiyakhand; Abe, Shigeto; Nishimura, Hidekazu; Kirimoto, Tetsuo; Matsui, Takemi
2017-02-01
Infrared thermography (IRT) is used to screen febrile passengers at international airports, but it suffers from low sensitivity. This study explored the application of a combined visible and thermal image processing approach that uses a CMOS camera equipped with IRT to remotely sense multiple vital signs and screen patients with suspected infectious diseases. An IRT system that produced visible and thermal images was used for image acquisition. The subjects' respiration rates were measured by monitoring temperature changes around the nasal areas on thermal images; facial skin temperatures were measured simultaneously. Facial blood circulation causes tiny color changes in visible facial images that enable the determination of the heart rate. A logistic regression discriminant function predicted the likelihood of infection within 10s, based on the measured vital signs. Sixteen patients with an influenza-like illness and 22 control subjects participated in a clinical test at a clinic in Fukushima, Japan. The vital-sign-based IRT screening system had a sensitivity of 87.5% and a negative predictive value of 91.7%; these values are higher than those of conventional fever-based screening approaches. Multiple vital-sign-based screening efficiently detected patients with suspected infectious diseases. It offers a promising alternative to conventional fever-based screening. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Chan, Christine L; Pyle, Laura; Kelsey, Megan; Newnes, Lindsey; Zeitler, Philip S; Nadeau, Kristen J
2016-05-01
Hemoglobin A1c (HbA1c) is increasingly performed over the oral glucose tolerance test (OGTT) as the initial screening test for type 2 diabetes in youth. However, the optimal strategy for identifying type 2 diabetes in youth remains controversial. Alternate glycemic markers have been proposed as potentially useful tools for diabetes screening. We examined the relationships among fructosamine (FA), glycated albumin (GA), and 1,5-anhydroglucitol (1,5-AG) with traditional screening tests, HbA1c and OGTT. Youth 10-18 yrs, BMI ≥85th‰, and HbA1c <7.5% had a single visit with measurement of HbA1c, 1,5-AG, FA, GA, and a standard OGTT. Distributions of FA, GA, and 1,5-AG by HbA1c and 2-hour glucose (2hG) categories were compared. Receiver operating characteristic (ROC)-curves were generated to determine the cut points at which alternate markers maximized sensitivity and specificity for predicting prediabetes and diabetes. One hundred and seventeen, 62% female, 59% Hispanic, 22% White, 17% black, median 14.1 yr, and body mass index (BMI) z-score 2.3 participated. Median values of each alternate marker differed significantly between prediabetes and diabetes HbA1c and 2hG categories (p < 0.017). Only GA medians differed (p = 0.006) between normal and prediabetes HbA1c. Area under the receiver operating characteristic curves (ROC-AUCs) for alternate markers as predictors of prediabetes (0.5-0.66) were low; however, alternate marker ROC-AUCs for identifying diabetes (0.82-0.98) were excellent. Although the alternate markers were poor predictors of prediabetes, they all performed well predicting diabetes by 2hG and HbA1c. Whereas the usefulness of these markers for identifying prediabetes is limited, they may be useful in certain scenarios as second line screening tools for diabetes in overweight/obese youth. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Aiding alternatives assessment with an uncertainty-tolerant hazard scoring method.
Faludi, Jeremy; Hoang, Tina; Gorman, Patrick; Mulvihill, Martin
2016-11-01
This research developed a single-score system to simplify and clarify decision-making in chemical alternatives assessment, accounting for uncertainty. Today, assessing alternatives to hazardous constituent chemicals is a difficult task-rather than comparing alternatives by a single definitive score, many independent toxicological variables must be considered at once, and data gaps are rampant. Thus, most hazard assessments are only comprehensible to toxicologists, but business leaders and politicians need simple scores to make decisions. In addition, they must balance hazard against other considerations, such as product functionality, and they must be aware of the high degrees of uncertainty in chemical hazard data. This research proposes a transparent, reproducible method to translate eighteen hazard endpoints into a simple numeric score with quantified uncertainty, alongside a similar product functionality score, to aid decisions between alternative products. The scoring method uses Clean Production Action's GreenScreen as a guide, but with a different method of score aggregation. It provides finer differentiation between scores than GreenScreen's four-point scale, and it displays uncertainty quantitatively in the final score. Displaying uncertainty also illustrates which alternatives are early in product development versus well-defined commercial products. This paper tested the proposed assessment method through a case study in the building industry, assessing alternatives to spray polyurethane foam insulation containing methylene diphenyl diisocyanate (MDI). The new hazard scoring method successfully identified trade-offs between different alternatives, showing finer resolution than GreenScreen Benchmarking. Sensitivity analysis showed that different weighting schemes in hazard scores had almost no effect on alternatives ranking, compared to uncertainty from data gaps. Copyright © 2016 Elsevier Ltd. All rights reserved.
An economic evaluation of a genetic screening program for Tay-Sachs disease.
Nelson, W B; Swint, J M; Caskey, C T
1978-01-01
The resolution of policy questions relating to medical genetic screening programs will not be without considerable difficulty. Examples include such issues as the optimal degree of screening program expansion, the relative values of screening for different genetic diseases, the appropriate sources of program funding (public vs. private), and the relative value of funding expanded genetic screening programs vs. research directed toward elimination of genetic traits themselves. Information on the net impact of the relevant alternatives is greatly needed, and this need will increase if the National Genetics Act receives funding approval. We have provided what is hopefully a contribution toward this end. While our analysis pertains to a specific disease and a specific screening program for that disease, the methodology is readily generalizable to other genetic diseases, as well as programs of any size or structure. Hopefully, this will serve to stimulate further research efforts that we believe are needed for the objective consideration of resource allocation alternatives. PMID:418675
An economic evaluation of a genetic screening program for Tay-Sachs disease.
Nelson, W B; Swint, J M; Caskey, C T
1978-03-01
The resolution of policy questions relating to medical genetic screening programs will not be without considerable difficulty. Examples include such issues as the optimal degree of screening program expansion, the relative values of screening for different genetic diseases, the appropriate sources of program funding (public vs. private), and the relative value of funding expanded genetic screening programs vs. research directed toward elimination of genetic traits themselves. Information on the net impact of the relevant alternatives is greatly needed, and this need will increase if the National Genetics Act receives funding approval. We have provided what is hopefully a contribution toward this end. While our analysis pertains to a specific disease and a specific screening program for that disease, the methodology is readily generalizable to other genetic diseases, as well as programs of any size or structure. Hopefully, this will serve to stimulate further research efforts that we believe are needed for the objective consideration of resource allocation alternatives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaikuad, Apirat, E-mail: apirat.chaikuad@sgc.ox.ac.uk; Knapp, Stefan; Johann Wolfgang Goethe-University, Building N240 Room 3.03, Max-von-Laue-Strasse 9, 60438 Frankfurt am Main
An alternative strategy for PEG sampling is suggested through the use of four newly defined PEG smears to enhance chemical space in reduced screens with a benefit towards protein crystallization. The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially availablemore » crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.« less
Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics
RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.
2015-01-01
BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665
Remediation alternatives for low-level herbicide contaminated groundwater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conger, R.M.
In early 1995, an evaluation of alternatives for remediation of a shallow groundwater plume containing low-levels of an organic herbicide was conducted at BASF Corporation, a petrochemical facility located in Ascension Parish, Louisiana. The contaminated site is located on an undeveloped portion of property within 1/4 mile of the east bank of the Mississippi River near the community of Geismar. Environmental assessment data indicated that about two acres of the thirty acre site had been contaminated from past waste management practices with the herbicide bentazon. Shallow soils and groundwater between 5 to 15 feet in depth were affected. Maximum concentrationsmore » of bentazon in groundwater were less than seven parts per million. To identify potentially feasible remediation alternatives, the environmental assessment data, available research, and cost effectiveness were reviewed. After consideration of a preliminary list of alternatives, only two potentially feasible alternatives could be identified. Groundwater pumping, the most commonly used remediation alternative, followed by carbon adsorption treatment was identified as was a new innovative alternative known as vegetative transpiration. This alternative relies on the natural transpiration processes of vegetation to bioremediate organic contaminants. Advantages identified during screening suggest that the transpiration method could be the best remediation alternative to address both economic and environmental factors. An experiment to test critical factors of the vegetatived transpiration alternative with bentazon was recommended before a final decision on feasibility can be made.« less
The Use of HFC (CFC Free) Processes at the NASA Stennis Space Center
NASA Technical Reports Server (NTRS)
Ross, Richard H.
1997-01-01
The search for ozone depleting alternative chemicals was heightened when, in 1990, the more than 65 countries that had signed the Montreal Protocol agreed to phase out completely by the year 2000. In 1992, then-president Bush advanced this date for the United States to January l, 1996. In 1991, it was realized that the planned phase out and eventual elimination of ozone depleting chemicals imposed by the Montreal Protocol and the resulting Clean Air Act (CAA) amendments would impact the cleaning and testing of aerospace hardware at the NASA Stennis Space Center. Because of this regulation, the Test & Engineering Sciences Laboratory has been working on solvent conversion studies to replace CFC-113. Aerospace hardware and test equipment used in rocket propulsion systems require extreme cleanliness levels to function and maintain their integrity. Because the cleanliness of aerospace hardware will be affected by the elimination of CFC-113; alternate cleaning technologies, including the use of fluoridated solvents have been studied as potential replacements. Several aqueous processes have been identified for cleaning moderately sized components. However, no known aqueous alternative exists for cleaning and validating T&ME and complex geometry based hardware. This paper discusses the choices and the methodologies that were used to screen potential alternatives to CFC-113.
Zhu, Naishu; Ma, Shining; Sun, Xiaofeng
2016-12-28
In this paper, active screen plasma nitriding (ASPN) treatment was performed on polyacrylonitrile carbon fiber papers. Electric resistivity and microwave loss factor of carbon fiber were described to establish the relationship between processing parameters and fiber's ability to absorb microwaves. The surface processing effect of carbon fiber could be characterized by dynamic thermal mechanical analyzer testing on composites made of carbon fiber. When the process temperature was at 175 °C, it was conducive to obtaining good performance of dynamical mechanical properties. The treatment provided a way to change microwave heating properties of carbon fiber paper by performing different treatment conditions, such as temperature and time parameters. Atomic force microscope, scanning electron microscope, and X-ray photoelectron spectroscopy analysis showed that, during the course of ASPN treatment on carbon fiber paper, nitrogen group was introduced and silicon group was removed. The treatment of nitrogen-doped carbon fiber paper represented an alternative promising candidate for microwave curing materials used in repairing and heating technology, furthermore, an efficient dielectric layer material for radar-absorbing structure composite in metamaterial technology.
A Case Study on Reducing Children's Screen Time: The Project of Screen Free Week
ERIC Educational Resources Information Center
Kara, Hatice Gözde Ertürk
2018-01-01
The current study aims to direct children to alternative activities within a week period by applying the project of screen free week to voluntary families. The ultimate aim of the study is to reduce children's screen time. The instrumental case study method; one of the qualitative research methods, was employed. Five children attending the…
Alternative toxicity assessment methods to characterize the hazards of chemical substances have been proposed to reduce animal testing and screen thousands of chemicals in an efficient manner. Resources to accomplish these goals include utilizing large in vitro chemical screening...
DEVELOPMENT OF AN OBJECTIVE AND QUANTIFIABLE TERATOLOGICAL SCREEN FOR USE IN ZEBRAFISH LARVAE.
To address EPA’s need to prioritize large numbers of chemicals for testing, a rapid, cost-effective in vivo screen for potential developmental toxicity using an alternative vertebrate species (zebrafish;Danio rerio) has been developed. A component of that screen is the observatio...
Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis
2017-11-01
Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.
Screening of filamentous fungi for antimicrobial silver nanoparticles synthesis.
Ottoni, Cristiane Angélica; Simões, Marta Filipa; Fernandes, Sara; Dos Santos, Jonas Gomes; da Silva, Elda Sabino; de Souza, Rodrigo Fernando Brambilla; Maiorano, Alfredo Eduardo
2017-12-01
The present work had the goal of screening a batch of 20 fungal strains, isolated from sugar cane plantation soil, in order to identify those capable of biosynthesis of silver nanoparticles. These nanoparticles are known to have a large and effective application in clinical microbiology. Four strains were found to be capable of biosynthesis of silver nanoparticles. The biosynthesised nanoparticles were characterised by UV-vis spectroscopy, scanning electron microscopy, EDX, and XRD. They were found to have an average size of 30-100 nm, a regular round shape, and potential antimicrobial activity against Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The antimicrobial activity was found to be directly related to the nanoparticles concentration. Mycogenic synthesis of nanoparticles is a green biogenic process preferable to other alternatives. Because fungi are great producers of extracellular enzymes this process makes scaling-up an easier task with high importance for clinical microbiology on the fight against microbial resistance, as well as for other industrial applications.
NASA Technical Reports Server (NTRS)
Lewis, James P.
1953-01-01
An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.
Chemical chronobiology: Toward drugs manipulating time.
Wallach, Thomas; Kramer, Achim
2015-06-22
Circadian clocks are endogenous timing systems orchestrating the daily regulation of a huge variety of physiological, metabolic and behavioral processes. These clocks are important for health - in mammals, their disruption leads to a diverse number of pathologies. While genetic and biochemical approaches largely uncovered the molecular bases of circadian rhythm generation, chemical biology strategies targeting the circadian oscillator by small chemical compounds are increasingly developed. Here, we review the recent progress in the identification of small molecules modulating circadian rhythms. We focus on high-throughput screening approaches using circadian bioluminescence reporter cell lines as well as describe alternative mechanistic screens. Furthermore, we discuss the potential for chemical optimization of small molecule ligands with regard to the recent progress in structural chronobiology. Copyright © 2015 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.
Ye, Lidan; Yang, Chengcheng; Yu, Hongwei
2018-01-01
With increasing concerns in sustainable development, biocatalysis has been recognized as a competitive alternative to traditional chemical routes in the past decades. As nature's biocatalysts, enzymes are able to catalyze a broad range of chemical transformations, not only with mild reaction conditions but also with high activity and selectivity. However, the insufficient activity or enantioselectivity of natural enzymes toward non-natural substrates limits their industrial application, while directed evolution provides a potent solution to this problem, thanks to its independence on detailed knowledge about the relationship between sequence, structure, and mechanism/function of the enzymes. A proper high-throughput screening (HTS) method is the key to successful and efficient directed evolution. In recent years, huge varieties of HTS methods have been developed for rapid evaluation of mutant libraries, ranging from in vitro screening to in vivo selection, from indicator addition to multi-enzyme system construction, and from plate screening to computation- or machine-assisted screening. Recently, there is a tendency to integrate directed evolution with metabolic engineering in biosynthesis, using metabolites as HTS indicators, which implies that directed evolution has transformed from molecular engineering to process engineering. This paper aims to provide an overview of HTS methods categorized based on the reaction principles or types by summarizing related studies published in recent years including the work from our group, to discuss assay design strategies and typical examples of HTS methods, and to share our understanding on HTS method development for directed evolution of enzymes involved in specific catalytic reactions or metabolic pathways.
Multidimensional Programming Methods for Energy Facility Siting: Alternative Approaches
NASA Technical Reports Server (NTRS)
Solomon, B. D.; Haynes, K. E.
1982-01-01
The use of multidimensional optimization methods in solving power plant siting problems, which are characterized by several conflicting, noncommensurable objectives is addressed. After a discussion of data requirements and exclusionary site screening methods for bounding the decision space, classes of multiobjective and goal programming models are discussed in the context of finite site selection. Advantages and limitations of these approaches are highlighted and the linkage of multidimensional methods with the subjective, behavioral components of the power plant siting process is emphasized.
Intelligent Advanced Communications IP Telephony Feasibility for the U.S. Navy. Volume 1
2007-10-01
Monitors Control and Bearer Designed by the There are no bearing Circuitry Health through Non - manufacture of the circuits to be testing in Selectable... controlled process, only replacing non -tactical end devices at first and then replacing tactical when the sailors and the commanding officers build up...looked at as an alternative to the touch screen in a non -software research . A complete review of development of voice is larger then this test bed can
Circling motion and screen edges as an alternative input method for on-screen target manipulation.
Ka, Hyun W; Simpson, Richard C
2017-04-01
To investigate a new alternative interaction method, called circling interface, for manipulating on-screen objects. To specify a target, the user makes a circling motion around the target. To specify a desired pointing command with the circling interface, each edge of the screen is used. The user selects a command before circling the target. To evaluate the circling interface, we conducted an experiment with 16 participants, comparing the performance on pointing tasks with different combinations of selection method (circling interface, physical mouse and dwelling interface) and input device (normal computer mouse, head pointer and joystick mouse emulator). A circling interface is compatible with many types of pointing devices, not requiring physical activation of mouse buttons, and is more efficient than dwell-clicking. Across all common pointing operations, the circling interface had a tendency to produce faster performance with a head-mounted mouse emulator than with a joystick mouse. The performance accuracy of the circling interface outperformed the dwelling interface. It was demonstrated that the circling interface has the potential as another alternative pointing method for selecting and manipulating objects in a graphical user interface. Implications for Rehabilitation A circling interface will improve clinical practice by providing an alternative pointing method that does not require physically activating mouse buttons and is more efficient than dwell-clicking. The Circling interface can also work with AAC devices.
ENVIRONMENTAL LIFE CYCLE ASSESSMENT OF GASOLINE ALTERNATIVES: MTBE AND ETHANOL ADDITIVES
Currently, the U.S. is considering options for additives to reformulated gasoline. To inform this debate the U.S. EPA's Office of Research and Development is conducting a screening life cycle assessment (LCA) of three gasoline alternatives. These alternatives include gasoline w...
Eisenberg, Daniel A; Yu, Mengjing; Lam, Carl W; Ogunseitan, Oladele A; Schoenung, Julie M
2013-09-15
Copper-indium-gallium-selenium-sulfide (CIGS) thin film photovoltaics are increasingly penetrating the market supply for consumer solar panels. Although CIGS is attractive for producing less greenhouse gas emissions than fossil-fuel based energy sources, CIGS manufacturing processes and solar cell devices use hazardous materials that should be carefully considered in evaluating and comparing net environmental benefits of energy products. Through this research, we present a case study on the toxicity hazards associated with alternative materials selection for CIGS manufacturing. We applied two numeric models, The Green Screen for Safer Chemicals and the Toxic Potential Indicator. To improve the sensitivity of the model outputs, we developed a novel, life cycle thinking based hazard assessment method that facilitates the projection of hazards throughout material life cycles. Our results show that the least hazardous CIGS solar cell device and manufacturing protocol consist of a titanium substrate, molybdenum metal back electrode, CuInS₂ p-type absorber deposited by spray pyrolysis, ZnS buffer deposited by spray ion layer gas reduction, ZnO:Ga transparent conducting oxide (TCO) deposited by sputtering, and the encapsulant polydimethylsiloxane. Copyright © 2013 Elsevier B.V. All rights reserved.
Fixed-facility workplace screening mammography.
Reynolds, H E; Larkin, G N; Jackson, V P; Hawes, D R
1997-02-01
Potential barriers to compliance with screening mammography guidelines include the cost and inconvenience involved with undergoing the procedure. Workplace screening with mobile mammography is one possible approach to the convenience barrier. However, fixed-facility workplace screening is a viable alternative for any company with a large workforce in one location. This paper describes our initial experience with one such fixed facility. The facility was a cooperative venture by a large pharmaceutical company and an academic radiology department to provide convenient, no-cost (to the patient) screening mammography to employees, dependents, and retirees more than 40 years old. The pharmaceutical company built the facility within its corporate headquarters and the academic radiology department provided the equipment and personnel. The company was billed a fixed cost per examination. In the first 22 months of operation, 4210 (of 4559 scheduled) screening mammograms were obtained. The mean age of the population was 53 years old. Ninety percent of the screening mammograms were interpreted as negative or benign; 10% required additional workup. Of the screened population, 62 biopsies were recommended and 60 were performed. Of these, 42 were benign and 18 malignant. The cancer detection rate was 4.3 per 1000 (0.43%). At the time of diagnosis, six patients were stage 0, 10 patients were stage I, one patient was stage II, and one patient was stage III. Eleven of the 18 patients had minimal cancers. Of the patients who completed a satisfaction survey, 97% percent expressed a high degree of satisfaction with the screening process and stated they would use the facility in the future. A fixed facility for workplace screening mammography is a viable way to provide nearly barrier-free access to high-quality mammography. Patient acceptance is high.
McLachlan, E; Anderson, S; Hawkes, D; Saville, M; Arabena, K
2018-02-01
To examine factors that enhance under-screened and never-screened women's completion of the self-collection alternative pathway of the Renewed National Cervical Screening Program (ncsp) in Victoria, Australia. With the Australian ncsp changing, starting on 1 December 2017, the Medical Services Advisory Committee (msac) recommended implementing human papillomavirus (hpv) testing using a self-collected sample for under-screened and never-screened populations. In response, a multi-agency group implemented an hpv self-collection pilot project to trial self-collection screening pathways for eligible women. Quantitative data were collected on participation rates and compliance rates with follow-up procedures across three primary health care settings. Forty women who self-collected were interviewed in a semi-structured format, and seven agency staff completed in-depth interviews. Qualitative data were used to identify and understand clinical and personal enablers that assisted women to complete self-collection cervical screening pathways successfully. Eighty-five per cent (10 women) of participants who tested positive for hpv successfully received their results and completed follow-up procedures as required. Two remaining participants also received hpv-positive results. However, agencies were unable to engage them in follow-up services and procedures. The overall participation rate in screening (self-collection or Pap test) was 85.7% (84 women), with 79 women self-collecting. Qualitative data indicated that clear explanations on self-collection, development of trusting, empathetic relationships with health professionals, and recognition of participants' past experiences were critical to the successful completion of the self-collection pathway. When asked about possible inhibitors to screening and to following up on results and appointments, women cited poor physical and mental health, as well as financial and other structural barriers. A well-implemented process, led by trusted, knowledgeable, and engaged health care professionals who can provide appropriate support and information, can assist under-screened and never-screened women to complete the hpv self-collection pathway successfully.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Litchfield, J.W.; Watts, R.L.; Gurwell, W.E.
A materials assessment methodology for identifying specific critical material requirements that could hinder the implementation of solar energy has been developed and demonstrated. The methodology involves an initial screening process, followed by a more detailed materials assessment. The detailed assessment considers such materials concerns and constraints as: process and production constraints, reserve and resource limitations, lack of alternative supply sources, geopolitical problems, environmental and energy concerns, time constraints, and economic constraints. Data for 55 bulk and 53 raw materials are currently available on the data base. These materials are required in the example photovoltaic systems. One photovoltaic system and thirteenmore » photovoltaic cells, ten solar heating and cooling systems, and two agricultural and industrial process heat systems have been characterized to define their engineering and bulk material requirements.« less
Comparison of Alternate and Original Items on the Montreal Cognitive Assessment
Lebedeva, Elena; Huang, Mei; Koski, Lisa
2016-01-01
Background The Montreal Cognitive Assessment (MoCA) is a screening tool for mild cognitive impairment (MCI) in elderly individuals. We hypothesized that measurement error when using the new alternate MoCA versions to monitor change over time could be related to the use of items that are not of comparable difficulty to their corresponding originals of similar content. The objective of this study was to compare the difficulty of the alternate MoCA items to the original ones. Methods Five selected items from alternate versions of the MoCA were included with items from the original MoCA administered adaptively to geriatric outpatients (N = 78). Rasch analysis was used to estimate the difficulty level of the items. Results None of the five items from the alternate versions matched the difficulty level of their corresponding original items. Conclusions This study demonstrates the potential benefits of a Rasch analysis-based approach for selecting items during the process of development of parallel forms. The results suggest that better match of the items from different MoCA forms by their difficulty would result in higher sensitivity to changes in cognitive function over time. PMID:27076861
[New guidelines in regard to cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Acosta-Altamirano, Gustavo; Moreno-Eutimio, Mario Adán; Vargas-Aguilar, Víctor Manuel
2014-01-01
Cancer screening programs have been successful in reducing the incidence and mortality due to cervical cancer. For more than a decade, the human papillomavirus test has been recommended as part of these programs, however, Pap tests is not currently recommended for women 65 years of age who participated adequately in screening programs, continuing with these screening programs is not needed. Screening programs will be different in special populations at greatest risk where tests are frequently needed or use of alternative methods.
Non-aqueous cleaning solvent substitution
NASA Technical Reports Server (NTRS)
Meier, Gerald J.
1994-01-01
A variety of environmental, safety, and health concerns exist over use of chlorinated and fluorinated cleaning solvents. Sandia National Laboratories, Lawrence Livermore National Laboratories, and the Kansas City Division of AlliedSignal have combined efforts to focus on finding alternative cleaning solvents and processes which are effective, environmentally safe, and compliant with local, state, and federal regulations. An alternative solvent has been identified, qualified, and implemented into production of complex electronic assemblies, where aqueous and semi-aqueous cleaning processes are not allowed. Extensive compatibility studies were performed with components, piece-parts, and materials. Electrical testing and accelerated aging were used to screen for detrimental, long-term effects. A terpene, d-limonene, was selected as the solvent of choice, and it was found to be compatible with the components and materials tested. A brief history of the overall project will be presented, along with representative cleaning efficiency results, compatibility results, and residual solvent data. The electronics industry is constantly searching for proven methods and environmentally-safe materials to use in manufacturing processes. The information in this presentation will provide another option to consider on future projects for applications requiring high levels of quality, reliability, and cleanliness from non-aqueous cleaning processes.
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2011-01-01
A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.
Liao, Wei-Ching; Chuang, Min-Chieh; Ho, Ja-An Annie
2013-12-15
Genetically modified (GM) technique, one of the modern biomolecular engineering technologies, has been deemed as profitable strategy to fight against global starvation. Yet rapid and reliable analytical method is deficient to evaluate the quality and potential risk of such resulting GM products. We herein present a biomolecular analytical system constructed with distinct biochemical activities to expedite the computational detection of genetically modified organisms (GMOs). The computational mechanism provides an alternative to the complex procedures commonly involved in the screening of GMOs. Given that the bioanalytical system is capable of processing promoter, coding and species genes, affirmative interpretations succeed to identify specified GM event in terms of both electrochemical and optical fashions. The biomolecular computational assay exhibits detection capability of genetically modified DNA below sub-nanomolar level and is found interference-free by abundant coexistence of non-GM DNA. This bioanalytical system, furthermore, sophisticates in array fashion operating multiplex screening against variable GM events. Such a biomolecular computational assay and biosensor holds great promise for rapid, cost-effective, and high-fidelity screening of GMO. Copyright © 2013 Elsevier B.V. All rights reserved.
Campbell, Christine; Kafwafwa, Savel; Brown, Hilary; Walker, Graeme; Madetsa, Belito; Deeny, Miriam; Kabota, Beatrice; Morton, David; Ter Haar, Reynier; Grant, Liz; Cubie, Heather A
2016-08-15
The incidence of cervical cancer in Malawi is the highest in the world and projected to increase in the absence of interventions. Although government policy supports screening using visual inspection with acetic acid (VIA), screening provision is limited due to lack of infrastructure, trained personnel, and the cost and availability of gas for cryotherapy. Recently, thermo-coagulation has been acknowledged as a safe and acceptable procedure suitable for low-resource settings. We introduced thermo-coagulation for treatment of VIA-positive lesions as an alternative to cryotherapy within a cervical screening service based on VIA, coupled with appropriate, sustainable pathways of care for women with high-grade lesions and cancers. Detailed planning was undertaken for VIA clinics, and approvals were obtained from the Ministry of Health, Regional and Village Chiefs. Educational resources were developed. Thermo-coagulators were introduced into hospital and health centre settings, with theoretical and practical training in safe use and maintenance of equipment. A total of 7,088 previously unscreened women attended VIA clinics between October 2013 and March 2015. Screening clinics were held daily in the hospital and weekly in the health centres. Overall, VIA positivity was 6.1%. Almost 90% received same day treatment in the hospital setting, and 3- to 6-month cure rates of more than 90% are observed. Thermo-coagulation proved feasible and acceptable in this setting. Effective implementation requires comprehensive training and provider support, ongoing competency assessment, quality assurance and improvement audit. Thermo-coagulation offers an effective alternative to cryotherapy and encouraged VIA screening of many more women. © 2016 The Authors International Journal of Cancer published by John Wiley & Sons Ltd on behalf of UICC.
Cervinka, Miroslav; Cervinková, Zuzana; Novák, Jan; Spicák, Jan; Rudolf, Emil; Peychl, Jan
2004-06-01
Alternatives and their teaching are an essential part of the curricula at the Faculty of Medicine. Dynamic screen-based video recordings are the most important type of alternative models employed for teaching purposes. Currently, the majority of teaching materials for this purpose are based on PowerPoint presentations, which are very popular because of their high versatility and visual impact. Furthermore, current developments in the field of image capturing devices and software enable the use of digitised video streams, tailored precisely to the specific situation. Here, we demonstrate that with reasonable financial resources, it is possible to prepare video sequences and to introduce them into the PowerPoint presentation, thereby shaping the teaching process according to individual students' needs and specificities.
Jacobson, Sheldon H; Yu, Ge; Jokela, Janet A
2016-07-01
This paper provides an alternative policy for Ebola entry screening at airports in the United States. This alternative policy considers a social contact tracing (SCT) risk level, in addition to the current health risk level used by the CDC. The performances of both policies are compared based on the scenarios that occur and the expected cost associated with implementing such policies. Sensitivity analysis is performed to identify conditions under which one policy dominates the other policy. This analysis takes into account that the alternative policy requires additional data collection, which is balanced by a more cost-effective allocation of resources. Copyright © 2016 Elsevier Inc. All rights reserved.
Feldman, Joshua; Davie, Sam; Kiran, Tara
2017-01-01
Our Family Health Team is located in Toronto, Canada and provides care to over 35 000 patients. Like many practices in Canada, we took an opportunistic approach to cervical, breast, and colorectal cancer screening. We wanted to shift to a proactive, population-based approach but were unable to systematically identify patients overdue for screening or calculate baseline screening rates. Our initiative had two goals: (1) to develop a method for systematically identifying patients eligible for screening and whether they were overdue and (2) to increase screening rates for cervical, breast, and colorectal cancer. Using external government data in combination with our practice's electronic medical record, we developed a process to identify patients eligible and overdue for cancer screening. After generating baseline data, we implemented an evidence-based, multifaceted intervention to improve cancer screening rates. We sent a personalized reminder letter to overdue patients, provided physicians with practice-level audit and feedback, and improved our electronic reminder function by updating charts with accurate data on the Fecal Occult Blood Test (FOBT). Following our initial intervention, we sought to maintain and further improve our screening rates by experimenting with alternative recall methods and collecting patient feedback. Screening rates significantly improved for all three cancers. Between March 2014 and December 2016, the cervical cancer screening rate increased from 60% to 71% (p<0.05), the breast cancer screening rate increased from 56% to 65% (p<0.05), and the overall colorectal screening rate increased from 59% to 70% (p<0.05). The increase in colorectal screening rates was largely due to an increase in FOBT screening from 18% to 25%, while colonoscopy screening remained relatively unchanged, shifting from 45% to 46%. We also found that patients living in low income neighbourhoods were less likely to be screened. Following our intervention, this equity gap narrowed modestly for breast and colorectal cancer but did not change for cervical cancer screening. Our future improvement efforts will be focused on reducing the gap in screening between patients living in low-income and high-income neighbourhoods while maintaining overall gains.
USDA-ARS?s Scientific Manuscript database
The comprehensive identification of genes underlying phenotypic variation of complex traits remains a major challenge. Most genome-wide screens lack sufficient resolving power as they typically depend on linkage. An alternate method is to screen for allele-specific expression (ASE), a simple yet pow...
Comparison of Screen Sizes When Using Video Prompting to Teach Adolescents with Autism
ERIC Educational Resources Information Center
Bennett, Kyle D.; Gutierrez, Anibal, Jr.; Loughrey, Tara O.
2016-01-01
Recently, researchers have compared the effectiveness of video-based instruction (VBI), particularly video modeling, when using smaller versus larger screen sizes with positive, but mixed results. Using an adapted alternating treatments design, we compared two different screen sizes (i.e., iPhone 5 versus iPad 2) using video prompting as the VBI…
Lee, Jaeyoung; Yasmin, Shamsunnahar; Eluru, Naveen; Abdel-Aty, Mohamed; Cai, Qing
2018-02-01
In traffic safety literature, crash frequency variables are analyzed using univariate count models or multivariate count models. In this study, we propose an alternative approach to modeling multiple crash frequency dependent variables. Instead of modeling the frequency of crashes we propose to analyze the proportion of crashes by vehicle type. A flexible mixed multinomial logit fractional split model is employed for analyzing the proportions of crashes by vehicle type at the macro-level. In this model, the proportion allocated to an alternative is probabilistically determined based on the alternative propensity as well as the propensity of all other alternatives. Thus, exogenous variables directly affect all alternatives. The approach is well suited to accommodate for large number of alternatives without a sizable increase in computational burden. The model was estimated using crash data at Traffic Analysis Zone (TAZ) level from Florida. The modeling results clearly illustrate the applicability of the proposed framework for crash proportion analysis. Further, the Excess Predicted Proportion (EPP)-a screening performance measure analogous to Highway Safety Manual (HSM), Excess Predicted Average Crash Frequency is proposed for hot zone identification. Using EPP, a statewide screening exercise by the various vehicle types considered in our analysis was undertaken. The screening results revealed that the spatial pattern of hot zones is substantially different across the various vehicle types considered. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
N /A
The proposed action and three alternatives, including a No Build alternative, were evaluated along the existing RWIPL alignment to accommodate the placement of the proposed RWIPL. Construction feasibility, reasonableness and potential environmental impacts were considered during the evaluation of the four actions (and action alternatives) for the proposed RWIPL activities. Reasonable actions were identified as those actions which were considered to be supported by common sense and sound technical principles. Feasible actions were those actions which were considered to be capable of being accomplished, practicable and non-excessive in terms of cost. The evaluation process considered the following design specifications, whichmore » were determined to be important to the feasibility of the overall project. The proposed RWIPL replacement project must therefore: (1) Comply with the existing design basis and criteria, (2) Maintain continuity of operation of the facility during construction, (3)Provide the required service life, (4) Be cost effective, (5)Improve the operation and maintenance of the pipeline, and (6) Maintain minimal environmental impact while meeting the performance requirements. Sizing of the pipe, piping construction materials, construction method (e.g., open-cut trench, directional drilling, etc.) and the acquisition of new Right-of-Way (ROW) were additionally evaluated in the preliminary alternative identification, selection and screening process.« less
Biological Concerns on the Selection of Animal Models for Teratogenic Testing.
Alves-Pimenta, Sofia; Colaço, Bruno; Oliveira, Paula A; Venâncio, Carlos
2018-01-01
During pregnancy fetus can be exposed to a variety of chemicals which may induce abortion and malformations. Due to the amounts of new substances coming into the market every year, a high demand for a rapid, reliable, and cost-effective method to detect potential toxicity is necessary. Different species have been used as animal models for teratogen screening, most of them sharing similar development processes with humans. However, the application of embryology knowledge to teratology is hampered by the complexity of the reproduction processes.The present chapter outlines the essential development periods in different models, and highlights the similarities and differences between species, advantages and disadvantages of each group, and specific sensitivities for teratogenic tests. These models can be organized into the following categories: (1) invertebrate species such Caenorhabditis elegans and Drosophila melanogaster, which have become ideal for screening simple mechanisms in the early periods of reproductive cycle, allowing for rapid results and minor ethical concerns; (2) vertebrate nonmammalian species such Xenopus laevis and Danio rerio, important models to assess teratogenic potential in later development with fewer ethical requirements; and (3) the mammalian species Mus musculus, Rattus norvegicus, and Oryctolagus cuniculus, phylogenetically more close to humans, essential to assess complex specialized processes, that occur later in development.Rules for development toxicology tests require the use of mammalian species. However, ethical concerns and costs limit their use in large-scale screening. By contrast, invertebrate and vertebrate nonmammalian species are increasing as alternative animal models, as these organisms combine less ethical requirements, low costs and culture conditions compatible with large-scale screening. In contrast to the in vitro techniques, their main advantage is to allow for high-throughput screening in a whole-animal context, not dependent on the prior identification of a target. In this chapter, the biological development of the animals most used in teratogenic tests is adressed with the aims of maximizing human translation, reducing the number of animals used, and the time to market for new drugs.
Skally, Mairead; Hanly, Paul; Sharp, Linda
2013-06-01
Fecal DNA (fDNA) testing is a noninvasive potential alternative to current colorectal cancer screening tests. We conducted a systematic review and quality assessment of studies of cost-effectiveness of fDNA as a colorectal cancer screening tool (compared with no screening and other screening modalities), and identified key variables that impinged on cost-effectiveness. We searched MEDLINE, Embase, and the Centre for Reviews and Dissemination for cost-effectiveness studies of fDNA-based screening, published in English by September 2011. Studies that undertook an economic evaluation of fDNA, using either a cost-effectiveness or cost-utility analysis, compared with other relevant screening modalities and/or no screening were included. Additional inclusion criteria related to the presentation of data pertaining to model variables including time horizon, costs, fDNA performance characteristics, screening uptake, and comparators. A total of 369 articles were initially identified for review. After removing duplicates and applying inclusion and exclusion criteria, seven articles were included in the final review. Data was abstracted on key descriptor variables including screening scenarios, time horizon, costs, test performance characteristics, screening uptake, comparators, and incremental cost-effectiveness ratios. Quality assessment was undertaken using a standard checklist for economic evaluations. Studies cited by cost-effectiveness articles as the source of data on fDNA test performance characteristics were also reviewed. Seven cost-effectiveness studies were included, from the USA (4), Canada (1), Israel (1), and Taiwan (1). Markov models (5), a partially observable Markov decision process model (1) and MISCAN and SimCRC (1) microsimulation models were used. All studies took a third-party payer perspective and one included, in addition, a societal perspective. Comparator screening tests, screening intervals, and specific fDNA tests varied between studies. fDNA sensitivity and specificity parameters were derived from 12 research studies and one meta-analysis. Outcomes assessed were life-years gained and quality-adjusted life-years gained. fDNA was cost-effective when compared with no screening in six studies. Compared with other screening modalities, fDNA was not considered cost-effective in any of the base-case analyses: in five studies it was dominated by all alternatives considered. Sensitivity analyses identified cost, compliance, and test parameters as key influential parameters. In general, poor presentation of "study design" and "data collection" details lowered the quality of included articles. Although the literature searches were designed for high sensitivity, the possibility cannot be excluded that some eligible studies may have been missed. Reports (such as Health Technology Assessments produced by government agencies) and other forms of grey literature were excluded because they are difficult to identify systematically and/or may not report methods and results in sufficient detail for assessment. On the basis of the available (albeit limited) evidence, while fDNA is cost-effective when compared with no screening, it is currently dominated by most of the other available screening options. Cost and test performance appear to be the main influences on cost-effectiveness.
Erden, Emre; Ucar, M. Cigdem; Gezer, Tekin; Pazarlioglu, Nurdan Kasikara
2009-01-01
This study presents new and alternative fungal strains for the production of ligninolytic enzymes which have great potential to use in industrial and biotechnological processes. Thirty autochthonous fungal strains were harvested from Bornova-Izmir in Turkiye. In the fresh fruitbody extracts laccase, manganese peroxidase and lignin peroxidase activities, which are the principal enzymes responsible for ligninocellulose degradation by Basidiomycetes, were screened. Spores of some of the basidiomycetes species such as Cortinarius sp., Trametes versicolor, Pleurotus ostreatus, Abortiporus biennis, Lyophyllum subglobisporium, Ramaria stricta, Ganoderma carnosum, Lactarius delicious ve Lepista nuda were isolated and investigated optimum cultivation conditions in submerged fermentation for high yields of ligninolytic enzyme production. In addition, isolated fungal strains were monitored on agar plates whether having the capability of decolorization of a textile dye Remazol Marine Blue. PMID:24031371
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W. II; Tsao, C.L.
1996-06-01
This report presents potential screening benchmarks for protection of aquatic life form contaminants in water. Because there is no guidance for screening for benchmarks, a set of alternative benchmarks is presented herein. This report presents the alternative benchmarks for chemicals that have been detected on the Oak Ridge Reservation. It also presents the data used to calculate the benchmarks and the sources of the data. It compares the benchmarks and discusses their relative conservatism and utility. Also included is the updates of benchmark values where appropriate, new benchmark values, secondary sources are replaced by primary sources, and a more completemore » documentation of the sources and derivation of all values are presented.« less
Norton, D M; McCamey, M; Boor, K J; Wiedmann, M
2000-03-01
The cold-smoked fish industry was used as a model for the development of a system for monitoring Listeria spp. in foods and in the food processing environment. A total of 214 samples including raw fish, fish during the cold-smoking process, finished product, and environmental samples were collected from three processing facilities over two visits to each facility. Samples were screened for Listeria spp. using the BAX for Screening/genus Listeria polymerase chain reaction system (PCR) and by culture. Listeria spp., confirmed by the API Listeria test strip or by a PCR assay targeting the L. monocytogenes hlyA gene, were isolated from a total of 89 (41.6%) samples. Of these, 80 samples also tested positive for Listeria spp. using the BAX system. Specifically, 42 (55.3%) environmental samples (n = 76), 11 (25.6%) raw materials samples (n = 43), 20 (35.1%) samples from fish in various stages of processing (n = 57), and 7 (18.4%) finished product samples (n = 38) tested positive for Listeria spp. using the BAX system. Five (4.0%) of the 125 culture-negative samples yielded BAX system-positive results. Listeria isolates from each of nine culture-positive/BAX system-negative samples yielded a positive reaction when tested in pure culture by the BAX system, suggesting that our false-negative results were likely due to the presence of low Listeria numbers in the initial enrichment as opposed to nonreacting isolates. The employment of alternative enrichment protocols, such as the two-step enrichment recommended by the manufacturer, may increase the sensitivity of the assay.
Sicaire, Anne-Gaëlle; Vian, Maryline; Fine, Frédéric; Joffre, Florent; Carré, Patrick; Tostain, Sylvain; Chemat, Farid
2015-01-01
The present study was designed to evaluate the performance of alternative bio-based solvents, more especially 2-methyltetrahydrofuran, obtained from crop’s byproducts for the substitution of petroleum solvents such as hexane in the extraction of fat and oils for food (edible oil) and non-food (bio fuel) applications. First a solvent selection as well as an evaluation of the performance was made with Hansen Solubility Parameters and the COnductor-like Screening MOdel for Realistic Solvation (COSMO-RS) simulations. Experiments were performed on rapeseed oil extraction at laboratory and pilot plant scale for the determination of lipid yields, extraction kinetics, diffusion modeling, and complete lipid composition in term of fatty acids and micronutrients (sterols, tocopherols and tocotrienols). Finally, economic and energetic evaluations of the process were conducted to estimate the cost of manufacturing using 2-methyltetrahydrofuran (MeTHF) as alternative solvent compared to hexane as petroleum solvent. PMID:25884332
Behavorial assessments of larval zebrafish neurotoxicology
Fishes have long been a popular organism in ecotoxicology research, and are increasingly used in human health research as an alternative animal model for chemical screening. Our laboratory incorporates a zebrafish (Danio rerio) embryo/larval assay to screen chemicals for developm...
ERIC Educational Resources Information Center
Mariz, Candice; Carter, Mark; Stephenson, Jennifer
2017-01-01
Visual presentations may assist students with autism spectrum disorder (ASD) to access instruction, and they may be more engaged when interacting with screen media in particular. Interactive whiteboards (IWBs) are large electronic screens that are used for instruction in many classrooms. An alternating treatment design was used to compare the…
Use of an interrupted time-series design to evaluate a cancer screening program.
Michielutte, R; Shelton, B; Paskett, E D; Tatum, C M; Velez, R
2000-10-01
An alternative approach to intervention-control designs to evaluate community health education studies is to use a quasi-experimental design in which the outcomes of interest are examined over time in the intervention unit. The Forsyth County Cancer Screening Project (FoCaS) was a comprehensive clinic- and community-based education program to increase screening for cervical cancer and breast cancer among low-income women. This paper reports the use of piecewise regression accounting for potential effects of auto-correlation in the data to evaluate the effectiveness of the project in increasing mammography screening. Data for the evaluation of trends in screening consisted of all mammograms performed during the period of May 1992 through June 1995 at the Reynolds Health Center in Forsyth County, North Carolina. The results suggested that the FoCaS project was effective in increasing mammography screening among women age 40 or older in the study population. Analysis of the trends by age indicated that the program had differential effects on women age 40-49 and 50 or older. The results demonstrate that analyses of the type presented here can either complement or serve as an alternative to more traditional intervention-control analyses.
Cell-free fetal DNA screening in the USA: a cost analysis of screening strategies.
Evans, M I; Sonek, J D; Hallahan, T W; Krantz, D A
2015-01-01
To determine whether implementation of primary cell-free fetal DNA (cffDNA) screening would be cost-effective in the USA and to evaluate potential lower-cost alternatives. Three strategies to screen for trisomy 21 were evaluated using decision tree analysis: 1) a primary strategy in which cffDNA screening was offered to all patients, 2) a contingent strategy in which cffDNA screening was offered only to patients who were high risk on traditional first-trimester screening and 3) a hybrid strategy in which cffDNA screening was offered to all patients ≥ 35 years of age and only to patients < 35 years who were high risk after first-trimester screening. Four traditional screening protocols were evaluated, each assessing nuchal translucency (NT) and pregnancy-associated plasma protein-A (PAPP-A) along with either free or total beta-human chorionic gonadotropin (β-hCG), with or without nasal bone (NB) assessment. Utilizing a primary cffDNA screening strategy, the cost per patient was 1017 US$. With a traditional screening protocol using free β-hCG, PAPP-A and NT assessment as part of a hybrid screening strategy, a contingent strategy with a 1/300 cut-off and a contingent strategy with a 1/1000 cut-off, the cost per patient was 474, 430 and 409 US$, respectively. Findings were similar using the other traditional screening protocols. Marginal cost per viable case detected for the primary screening strategy as compared to the other strategies was 3-16 times greater than the cost of care for a missed case. Primary cffDNA screening is not currently a cost-effective strategy. The contingent strategy was the lowest-cost alternative, especially with a risk cut-off of 1/1000. The hybrid strategy, although less costly than primary cffDNA screening, was more costly than the contingent strategy. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Eco-Friendly Extraction of Biopolymer Chitin and Carotenoids from Shrimp Waste
NASA Astrophysics Data System (ADS)
Prameela, K.; Venkatesh, K.; Divya vani, K.; Sudesh Kumar, E.; Mohan, CH Murali
2017-08-01
Astaxanthin a nutraceutical and chitin a natural biopolymer present in shrimp waste. In current chemical extraction methods HCl and NaOH are used for extraction and these chemicals are introduced into aquatic ecosystems are spoiling aquatic flora and fauna, pollute the environment and destroy astaxanthin. Lactobacillus species were isolated from gut of Solenocera melantho and characterized phenotypically and genotypically. Initial screening experiments have shown to be an effective and identified as Lactobacillus plantaram based on morphological, biochemical characteristics and molecular analysis. Efficiency of fermentation has shown with good yield of astaxanthin and recovery of chitin. Hence this alternative microbial process is having advantage than existing hazardous, non-economical chemical process.
Detecting Developmental Neurotoxicants Using Zebrafish Embryos
As part of EPA’s program on the screening and prioritization of chemicals for developmental neurotoxicity, a rapid, cost-effective in vivo vertebrate screen is being developed using an alternative species approach. Zebrafish (Danio rerio), a small freshwater fish with external f...
Bolaños-Díaz, Rafael; Tejada, Romina A; Beltrán, Jessica; Escobedo-Palza, Seimer
2016-01-01
To determine the cost-effectiveness of human papillomavirus (HPV) vaccination and cervical lesion screening versus screening alone for the prevention of uterine cervical cancer (UCC). This cost-effectiveness evaluation from the perspective of the Ministry of Health employed a Markov model with a 70-year time horizon and three alternatives for UCC prevention (screening alone, screening + bivalent vaccine, and screening + quadrivalent vaccine) in a hypothetical cohort of 10-year-old girls. Our model, which was particularly sensitive to variations in coverage and in the prevalence of persistent infection by oncologic genotypes not included in the vaccine, revealed that HPV vaccination and screening is more cost-effective than screening alone, assuming a payment availability from S/ 2 000 (US dollars (USD) 1 290.32) per subject. In the deterministic analysis, the bivalent vaccine was marginally more cost-effective than the quadrivalent vaccine (S/ 48 [USD 30.97] vs. S/ 166 [USD 107.10] per quality-adjusted life-year, respectively). However, in the probabilistic analysis, both interventions generated clouds of overlapping points and were thus cost-effective and interchangeable, although the quadrivalent vaccine tended to be more cost-effective. Assuming a payment availability from S/ 2000 [USD 1,290.32], screening and vaccination were more cost-effective than screening alone. The difference in cost-effectiveness between the two vaccines lacked probabilistic robustness, and therefore the vaccines can be considered interchangeable from a cost-effectiveness perspective.
Anttila, Ahti; Pokhrel, Arun; Kotaniemi-Talonen, Laura; Hakama, Matti; Malila, Nea; Nieminen, Pekka
2011-03-01
The purpose was to evaluate alternative cytological screening methods in population-based screening for cervical cancer up to cancer incidence and mortality outcome. Automation-assisted screening was compared to conventional cytological screening in a randomized design. The study was based on follow-up of 503,391 women invited in the Finnish cervical cancer screening program during 1999-2003. The endpoints were incident cervical cancer, severe intraepithelial neoplasia and deaths from cervical cancer. One third of the women had been randomly allocated to automation-assisted screening and two thirds to conventional cytology. Information on cervical cancer and severe neoplasia were obtained through 1999-2007 from a linkage between screening and cancer registry files. There were altogether 3.2 million woman-years at risk, and the average follow-up time was 6.3 years. There was no difference in the risk of cervical cancer between the automation-assisted and conventional screening methods; the relative risk (RR) of cervical cancer between the study and control arm was 1.00 (95% confidence interval [CI] = 0.76-1.29) among all invited and 1.08 (95% CI = 0.76-1.51) among women who were test negative at entry. Comparing women who were test negative with nonscreened, RR of cervical cancer incidence was 0.26, 95% CI = 0.19-0.36 and of mortality 0.24 (0.13-0.43). Both methods were valid for screening. Because cervical cancer is rare in our country, we cannot rule out small differences between methods. Evidence on alternative methods for cervical cancer screening is increasing and it is thus feasible to evaluate new methods in large-scale population-based screening programs up to cancer outcome. Copyright © 2010 UICC.
EJSCREEN Version 1, EJ Index Alternatives
This map service displays alternative environmental justice (EJ) indexes used in EJSCREEN. The alternative EJ indexes combine each of the 12 environmental indicators and one of two demographic indexes using different methods than the Primary EJ Index. EJ Index Alternative 1 is a combination of a blockgroup environmental factor, the populaiton of the blockgroup, and the demographic index. This EJ Index measures how much a particular place contributes to the total burden faced by subpopulations highlighted by the demographic index. EJ Index Alternative 2 is a combination of a blockgroup environmental factor and the demographic index. Two options are presented for both EJ Index Alternative 1 and Alternative 2-- they are combined with the primary demographic index and alternative demographic index. EJSCREEN is an environmental justice screening tool that provides EPA with a nationally consistent approach to screening for potential areas of EJ concern that may warrant further investigation. The EJ indexes are block group level results that combine multiple demographic factors with a single environmental variable (such as proximity to traffic) that can be used to help identify communities living with the greatest potential for negative environmental and health effects. The EJSCREEN tool is currently for internal EPA use only. It is anticipated that as users become accustomed to this new tool, individual programs within the Agency will develop program use guidelines a
Rychetnik, Lucie; Doust, Jenny; Thomas, Rae; Gardiner, Robert; Mackenzie, Geraldine; Glasziou, Paul
2014-04-30
Cancer screening policies and programmes should take account of public values and concerns. This study sought to determine the priorities, values and concerns of men who were 'fully informed' about the benefits and harms of prostate-specific antigen (PSA) screening; and empirically examine the value of a community jury in eliciting public values on PSA screening. Community jury was convened on the Gold Coast, Queensland (Australia) to consider PSA screening benefits and harms, and whether government campaigns on PSA screening should be conducted. 27 men (volunteers) aged 50-70 with no personal history of prostate cancer and willing to attend jury 6-7 April 2013: 12 were randomly allocated to jury (11 attended). A qualitative analysis was conducted of the jury deliberations (audio-recorded and transcribed) to elicit the jury's views and recommendations. A survey determined the impact of the jury process on participants' individual testing decisions compared with control group. The jury concluded governments should not invest in programmes focused on PSA screening directed at the public because the PSA test did not offer sufficient reassurance or benefit and could raise unnecessary alarm. It recommended an alternative programme to support general practitioners to provide patients with better quality and more consistent information about PSA screening. After the jury, participants were less likely to be tested in the future compared with the controls, but around half said they would still consider doing so. The jury's unanimous verdict about government programmes was notable in the light of their divergent views on whether or not they would be screened themselves in the future. Community juries provide valuable insights into the priorities and concerns of men weighing up the benefits and harms of PSA screening. It will be important to assess the degree to which the findings are generalisable to other settings.
Schneider, Teresa; Graeff-Honninger, Simone; French, William Todd; ...
2012-01-01
The production of biodiesel has notably increased over the past decade. Currently, plant oil is the main feedstock for biodiesel production, but, due to concerns related to the competition with food production, alternative oil feedstocks have to be found. Oleaginous yeasts are known to produce high amounts of lipids, but no integrated process from microbial fermentation to final biodiesel production has reached commercial realization yet due to economic constraints. Therefore, growth and lipid production of red yeast Rhodotorula glutinis was tested on low-cost substrates, namely, wastewaters from potato, fruit juice, and lettuce processing. Additionally, the production of carotenoids as high-valuemore » by-products was examined. All evaluated wastewaters met the general criteria for microbial lipid production. However, no significant increase in lipid content was observed, probably due to lack of available carbon in wastewaters from fruit juice and lettuce processing, and excess of available nitrogen in potato processing wastewater, respectively. During growth on wastewaters from fruit juice and lettuce processing the carotenoid content increased significantly in the first 48 hours. The relations between carbon content, nitrogen content, and carotenoid production need to be further assessed. For economic viability, lipid and carotenoid production needs to be increased significantly. Lastly, the screening of feedstocks should be extended to other wastewaters.« less
Alternative Approaches for Screening Contaminated Sediments and Soils for PCDD/PCDF
Generating analytical data for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) using the traditional high resolution mass spectrometry (HRMS) analysis method, EPA Method 1613B, is time-consuming and expensive. Consequently, alternative methods to ...
Wearing surface testing and screening : Yukon River Bridge.
DOT National Transportation Integrated Search
2015-09-01
There is a demand and a need for cheaper and alternative surface coverings in environments with high temperature fluctuations. Our : design for an alternative surface covering involves a basic two-part component epoxy with the addition of a solvent. ...
Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick
2015-01-01
Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020
Kafwafwa, Savel; Brown, Hilary; Walker, Graeme; Madetsa, Belito; Deeny, Miriam; Kabota, Beatrice; Morton, David; Ter Haar, Reynier; Grant, Liz; Cubie, Heather A.
2016-01-01
The incidence of cervical cancer in Malawi is the highest in the world and projected to increase in the absence of interventions. Although government policy supports screening using visual inspection with acetic acid (VIA), screening provision is limited due to lack of infrastructure, trained personnel, and the cost and availability of gas for cryotherapy. Recently, thermo‐coagulation has been acknowledged as a safe and acceptable procedure suitable for low‐resource settings. We introduced thermo‐coagulation for treatment of VIA‐positive lesions as an alternative to cryotherapy within a cervical screening service based on VIA, coupled with appropriate, sustainable pathways of care for women with high‐grade lesions and cancers. Detailed planning was undertaken for VIA clinics, and approvals were obtained from the Ministry of Health, Regional and Village Chiefs. Educational resources were developed. Thermo‐coagulators were introduced into hospital and health centre settings, with theoretical and practical training in safe use and maintenance of equipment. A total of 7,088 previously unscreened women attended VIA clinics between October 2013 and March 2015. Screening clinics were held daily in the hospital and weekly in the health centres. Overall, VIA positivity was 6.1%. Almost 90% received same day treatment in the hospital setting, and 3‐ to 6‐month cure rates of more than 90% are observed. Thermo‐coagulation proved feasible and acceptable in this setting. Effective implementation requires comprehensive training and provider support, ongoing competency assessment, quality assurance and improvement audit. Thermo‐coagulation offers an effective alternative to cryotherapy and encouraged VIA screening of many more women. PMID:27006131
Brodeur, M; Lepore, F; Lepage, M; Bacon, B A; Jemel, B; Debruille, J B
2008-01-31
The mechanisms responsible for the perception of illusory modal figures are usually studied by presenting entire Kanizsa figures at stimulus onset. However, with this mode of presentation, the brain activity generated by the inducers (the 'pacmen') is difficult to differentiate from the activity underlying the perception of the illusory figure. Therefore, in addition to this usual presentation mode, we used an alternative presentation mode. Inducer disks remained permanently on the screen and the illusory figure was induced by just removing the notches from the disks. The results support the heuristic value of this alternative mode of presentation. The P1 deflection of the visual evoked potentials (VEPs) was found to be greater for the illusory modal figure than for its control and for an amodal figure. This modulation is one of the earliest direct evidences for a low-level processing of illusory forms in the human brain. Meanwhile, larger N1s were obtained for the control figures than for the illusory figures in the notch mode of presentation. While this new type of N1 modulation could shed some light on the stage of processing indexed by this deflection, several propositions are put forward to account for the P1 and N1 variations found.
Geiger, Simon; Kasian, Olga; Mingers, Andrea M; Nicley, Shannon S; Haenen, Ken; Mayrhofer, Karl J J; Cherevko, Serhiy
2017-09-18
In searching for alternative oxygen evolution reaction (OER) catalysts for acidic water splitting, fast screening of the material intrinsic activity and stability in half-cell tests is of vital importance. The screening process significantly accelerates the discovery of new promising materials without the need of time-consuming real-cell analysis. In commonly employed tests, a conclusion on the catalyst stability is drawn solely on the basis of electrochemical data, for example, by evaluating potential-versus-time profiles. Herein important limitations of such approaches, which are related to the degradation of the backing electrode material, are demonstrated. State-of-the-art Ir-black powder is investigated for OER activity and for dissolution as a function of the backing electrode material. Even at very short time intervals materials like glassy carbon passivate, increasing the contact resistance and concealing the degradation phenomena of the electrocatalyst itself. Alternative backing electrodes like gold and boron-doped diamond show better stability and are thus recommended for short accelerated aging investigations. Moreover, parallel quantification of dissolution products in the electrolyte is shown to be of great importance for comparing OER catalyst feasibility. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jan, Arif Tasleem; Azam, Mudsser; Choi, Inho; Ali, Arif; Haq, Qazi Mohd. Rizwanul
2016-01-01
Mercury, which is ubiquitous and recalcitrant to biodegradation processes, threatens human health by escaping to the environment via various natural and anthropogenic activities. Non-biodegradability of mercury pollutants has necessitated the development and implementation of economic alternatives with promising potential to remove metals from the environment. Enhancement of microbial based remediation strategies through genetic engineering approaches provides one such alternative with a promising future. In this study, bacterial isolates inhabiting polluted sites were screened for tolerance to varying concentrations of mercuric chloride. Following identification, several Pseudomonas and Klebsiella species were found to exhibit the highest tolerance to both organic and inorganic mercury. Screened bacterial isolates were examined for their genetic make-up in terms of the presence of genes (merP and merT) involved in the transport of mercury across the membrane either alone or in combination to deal with the toxic mercury. Gene sequence analysis revealed that the merP gene showed 86–99% homology, while the merT gene showed >98% homology with previously reported sequences. By exploring the genes involved in imparting metal resistance to bacteria, this study will serve to highlight the credentials that are particularly advantageous for their practical application to remediation of mercury from the environment. PMID:26887227
Alonso, Pau; Osca, Joaquín; Cano, Oscar; Pimenta, Pedro; Andrés, Ana; Yagüe, Jaime; Millet, José; Rueda, Joaquín; Sancho-Tello, María José
2017-02-01
Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P < 0.0001) and a trend to higher number of appropriate leads in right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P < 0.001). Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population. © 2017 Wiley Periodicals, Inc.
Johnson, Susan L; Tabaei, Bahman P; Herman, William H
2005-02-01
To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.
Haug, Ulrike; Knudsen, Amy B; Lansdorp-Vogelaar, Iris; Kuntz, Karen M
2015-06-15
Researchers are actively pursuing the development of a new non-invasive test (NIT) for colorectal cancer (CRC) screening as an alternative to fecal occult blood tests (FOBTs). The majority of pilot studies focus on the detection of invasive CRC rather than precursor lesions (i.e., adenomas). We aimed to explore the relevance of adenoma detection for the viability of an NIT for CRC screening by considering a hypothetical test that does not detect adenomas beyond chance. We used the Simulation Model of Colorectal Cancer (SimCRC) to estimate the effectiveness of CRC screening and the lifetime costs (payers' perspective) for a cohort of US 50-years-old persons to whom CRC screening is offered from age 50-75. We compared annual screening with guaiac and immunochemical FOBTs (with sensitivities up to 70 and 24% for CRC and adenomas, respectively) to annual screening with a hypothetical NIT (sensitivity of 90% for CRC, no detection of adenomas beyond chance, specificity and cost similar to FOBTs). Screening with the NIT was not more effective, but was 29-44% more costly than screening with FOBTs. The findings were robust to varying the screening interval, the NIT's sensitivity for CRC, adherence rates favoring the NIT, and the NIT's unit cost. A comparative modelling approach using a model that assumes a shorter adenoma dwell time (MISCAN-COLON) confirmed the superiority of the immunochemical FOBT over an NIT with no ability to detect adenomas. Information on adenoma detection is crucial to determine whether a new NIT is a viable alternative to FOBTs for CRC screening. Current evidence thus lacks an important piece of information to identify marker candidates that hold real promise and deserve further (large-scale) evaluation. © 2014 UICC.
Addressing safety aspects of drugs and environmental chemicals has historically been undertaken through animal testing. However, the quantity of chemicals needing assessment and the challenge of species extrapolation require development of alternative approaches. Assessing phenot...
DEMONSTRATION OF WATERBASED PLATEN ADHESIVES FOR GARMENT SCREEN PRINTERS
The paper discusses a demonstration of waterbased platen adhesives as a viable alternative to the organic-based aerosol adhesives that are predominantly used by garment screen printers to affix garments or fabric pieces to print platens. o demonstrate this, the effectiveness of s...
Identifying Structural Alerts Based on Zebrafish Developmental Morphological Toxicity (TDS)
Zebrafish constitute a powerful alternative animal model for chemical hazard evaluation. To provide an in vivo complement to high-throughput screening data from the ToxCast program, zebrafish developmental toxicity screens were conducted on the ToxCast Phase I (Padilla et al., 20...
Sparse information exists on many chemicals to guide developmental neurotoxicity (DNT) risk assessments. As DNT testing using rodents is laborious and expensive, alternative species such as zebrafish are being adapted for toxicity screening. Assessing the DNT potential of chem...
The U.S. Environmental Protection Agency is evaluating methods to screen and prioritize large numbers of chemicals for developmental toxicity. As such, we are exploring a behavioral testing paradigm, which can assess the effect of sublethal and subteratogenic concentrations of de...
The U.S. Environmental Protection Agency is developing and evaluating methods to screen and prioritize large numbers of chemicals for developmental toxicity. Towards this goal, we are exploring methods to detect developmental neurotoxicants in very young larval zebrafish. We have...
Phase I and II feasibility study report for the 300-FF-5 operable unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1993-12-31
The purpose of this Phase I/II feasibility study is to assemble and screen a list of alternatives for remediation of the 300-FF-5 operable site on the Hanford Reservation. This screening is based on information gathered in the Phase I Remedial Investigation (RI) and on currently available information on remediation technologies. The alternatives remaining after screening provide a range of response actions for remediation. In addition, key data needs are identified for collection during a Phase II RI (if necessary). This Phase I/II FS represents a primary document as defined by the Tri-Party Agreement, but will be followed by a Phasemore » III FS that will further develop the alternatives and provide a detailed evaluation of them. The following remedial action objectives were identified for the 300-FF-5 operable unit: Limit current human exposure to contaminated groundwater in the unit; Limit discharge of contaminated groundwater to the Columbia River; Reduce contaminant concentrations in groundwater below acceptable levels by the year 2018.« less
Systematic review of the methodological and reporting quality of case series in surgery.
Agha, R A; Fowler, A J; Lee, S-Y; Gundogan, B; Whitehurst, K; Sagoo, H K; Jeong, K J L; Altman, D G; Orgill, D P
2016-09-01
Case series are an important and common study type. No guideline exists for reporting case series and there is evidence of key data being missed from such reports. The first step in the process of developing a methodologically sound reporting guideline is a systematic review of literature relevant to the reporting deficiencies of case series. A systematic review of methodological and reporting quality in surgical case series was performed. The electronic search strategy was developed by an information specialist and included MEDLINE, Embase, Cochrane Methods Register, Science Citation Index and Conference Proceedings Citation index, from the start of indexing to 5 November 2014. Independent screening, eligibility assessments and data extraction were performed. Included articles were then analysed for five areas of deficiency: failure to use standardized definitions, missing or selective data (including the omission of whole cases or important variables), transparency or incomplete reporting, whether alternative study designs were considered, and other issues. Database searching identified 2205 records. Through the process of screening and eligibility assessments, 92 articles met inclusion criteria. Frequencies of methodological and reporting issues identified were: failure to use standardized definitions (57 per cent), missing or selective data (66 per cent), transparency or incomplete reporting (70 per cent), whether alternative study designs were considered (11 per cent) and other issues (52 per cent). The methodological and reporting quality of surgical case series needs improvement. The data indicate that evidence-based guidelines for the conduct and reporting of case series may be useful. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.
Efficient discovery of responses of proteins to compounds using active learning
2014-01-01
Background Drug discovery and development has been aided by high throughput screening methods that detect compound effects on a single target. However, when using focused initial screening, undesirable secondary effects are often detected late in the development process after significant investment has been made. An alternative approach would be to screen against undesired effects early in the process, but the number of possible secondary targets makes this prohibitively expensive. Results This paper describes methods for making this global approach practical by constructing predictive models for many target responses to many compounds and using them to guide experimentation. We demonstrate for the first time that by jointly modeling targets and compounds using descriptive features and using active machine learning methods, accurate models can be built by doing only a small fraction of possible experiments. The methods were evaluated by computational experiments using a dataset of 177 assays and 20,000 compounds constructed from the PubChem database. Conclusions An average of nearly 60% of all hits in the dataset were found after exploring only 3% of the experimental space which suggests that active learning can be used to enable more complete characterization of compound effects than otherwise affordable. The methods described are also likely to find widespread application outside drug discovery, such as for characterizing the effects of a large number of compounds or inhibitory RNAs on a large number of cell or tissue phenotypes. PMID:24884564
Systematic procedure for designing processes with multiple environmental objectives.
Kim, Ki-Joo; Smith, Raymond L
2005-04-01
Evaluation of multiple objectives is very important in designing environmentally benign processes. It requires a systematic procedure for solving multiobjective decision-making problems due to the complex nature of the problems, the need for complex assessments, and the complicated analysis of multidimensional results. In this paper, a novel systematic procedure is presented for designing processes with multiple environmental objectives. This procedure has four steps: initialization, screening, evaluation, and visualization. The first two steps are used for systematic problem formulation based on mass and energy estimation and order of magnitude analysis. In the third step, an efficient parallel multiobjective steady-state genetic algorithm is applied to design environmentally benign and economically viable processes and to provide more accurate and uniform Pareto optimal solutions. In the last step a new visualization technique for illustrating multiple objectives and their design parameters on the same diagram is developed. Through these integrated steps the decision-maker can easily determine design alternatives with respect to his or her preferences. Most importantly, this technique is independent of the number of objectives and design parameters. As a case study, acetic acid recovery from aqueous waste mixtures is investigated by minimizing eight potential environmental impacts and maximizing total profit. After applying the systematic procedure, the most preferred design alternatives and their design parameters are easily identified.
McLachlan, E.; Anderson, S.; Hawkes, D.; Saville, M.; Arabena, K.
2018-01-01
Objectives To examine factors that enhance under-screened and never-screened women’s completion of the self-collection alternative pathway of the Renewed National Cervical Screening Program (ncsp) in Victoria, Australia. Background With the Australian ncsp changing, starting on 1 December 2017, the Medical Services Advisory Committee (msac) recommended implementing human papillomavirus (hpv) testing using a self-collected sample for under-screened and never-screened populations. In response, a multi-agency group implemented an hpv self-collection pilot project to trial self-collection screening pathways for eligible women. Methods Quantitative data were collected on participation rates and compliance rates with follow-up procedures across three primary health care settings. Forty women who self-collected were interviewed in a semi-structured format, and seven agency staff completed in-depth interviews. Qualitative data were used to identify and understand clinical and personal enablers that assisted women to complete self-collection cervical screening pathways successfully. Results Eighty-five per cent (10 women) of participants who tested positive for hpv successfully received their results and completed follow-up procedures as required. Two remaining participants also received hpv-positive results. However, agencies were unable to engage them in follow-up services and procedures. The overall participation rate in screening (self-collection or Pap test) was 85.7% (84 women), with 79 women self-collecting. Qualitative data indicated that clear explanations on self-collection, development of trusting, empathetic relationships with health professionals, and recognition of participants’ past experiences were critical to the successful completion of the self-collection pathway. When asked about possible inhibitors to screening and to following up on results and appointments, women cited poor physical and mental health, as well as financial and other structural barriers. Conclusion A well-implemented process, led by trusted, knowledgeable, and engaged health care professionals who can provide appropriate support and information, can assist under-screened and never-screened women to complete the hpv self-collection pathway successfully. PMID:29507491
The applicability of chemical alternatives assessment for engineered nanomaterials.
Hjorth, Rune; Hansen, Steffen Foss; Jacobs, Molly; Tickner, Joel; Ellenbecker, Michael; Baun, Anders
2017-01-01
The use of alternatives assessment to substitute hazardous chemicals with inherently safer options is gaining momentum worldwide as a legislative and corporate strategy to minimize consumer, occupational, and environmental risks. Engineered nanomaterials represent an interesting case for alternatives assessment approaches, because they can be considered both emerging "chemicals" of concern, as well as potentially safer alternatives to hazardous chemicals. However, comparing the hazards of nanomaterials to traditional chemicals or to other nanomaterials is challenging, and critical elements in chemical hazard and exposure assessment may have to be fundamentally altered to sufficiently address nanomaterials. The aim of this paper is to assess the overall applicability of alternatives assessment methods for nanomaterials and to outline recommendations to enhance their use in this context. The present paper focuses on the adaptability of existing hazard and exposure assessment approaches to engineered nanomaterials as well as strategies to design inherently safer nanomaterials. We argue that alternatives assessment for nanomaterials is complicated by the sheer number of nanomaterials possible. As a result, the inclusion of new data tools that can efficiently and effectively evaluate nanomaterials as substitutes is needed to strengthen the alternatives assessment process. However, we conclude that with additional tools to enhance traditional hazard and exposure assessment modules of alternatives assessment, such as the use of mechanistic toxicity screens and control banding tools, alternatives assessment can be adapted to evaluate engineered nanomaterials as potential substitutes for chemicals of concern and to ensure safer nanomaterials are incorporated in the design of new products. Integr Environ Assess Manag 2017;13:177-187. © 2016 SETAC. © 2016 SETAC.
Robotham, Julie V; Deeny, Sarah R; Fuller, Chris; Hopkins, Susan; Cookson, Barry; Stone, Sheldon
2016-03-01
In December, 2010, National Health Service (NHS) England introduced national mandatory screening of all admissions for meticillin-resistant Staphylococcus aureus (MRSA). We aimed to assess the effectiveness and cost-effectiveness of this policy, from a regional or national health-care decision makers' perspective, compared with alternative screening strategies. We used an individual-based dynamic transmission model parameterised with national MRSA audit data to assess the effectiveness and cost-effectiveness of admission screening of patients in English NHS hospitals compared with five alternative strategies (including no screening, checklist-activated screening, and high-risk specialty-based screening), accompanied by patient isolation and decolonisation, over a 5 year time horizon. We evaluated strategies for different NHS hospital types (acute, teaching, and specialist), MRSA prevalence, and transmission potentials using probabilistic sensitivity analyses. Compared with no screening, mean cost per quality-adjusted life-year (QALY) of screening all admissions was £89,000-148,000 (range £68,000-222,000), and this strategy was consistently more costly and less effective than alternatives for all hospital types. At a £30,000/QALY willingness-to-pay threshold and current prevalence, only the no-screening strategy was cost effective. The next best strategies were, in acute and teaching hospitals, targeting of high-risk specialty admissions (30-40% chance of cost-effectiveness; mean incremental cost-effectiveness ratios [ICERs] £45,200 [range £35,300-61,400] and £48,000/QALY [£34,600-74,800], respectively) and, in specialist hospitals, screening these patients plus risk-factor-based screening of low-risk specialties (a roughly 20% chance of cost-effectiveness; mean ICER £62,600/QALY [£48,000-89,400]). As prevalence and transmission increased, targeting of high-risk specialties became the optimum strategy at the NHS willingness-to-pay threshold (£30,000/QALY). Switching from screening all admissions to only high-risk specialty admissions resulted in a mean reduction in total costs per year (not considering uncertainty) of £2·7 million per acute hospital, £2·9 million per teaching, and £474,000 per specialist hospital for a minimum rise in infections (about one infection per year per hospital). Our results show that screening all admissions for MRSA is unlikely to be cost effective in England at the current NHS willingness-to-pay threshold, and our findings informed modified guidance to NHS England in 2014. Screening admissions to high-risk specialties is likely to represent better resource use in terms of cost per QALY gained. UK Department of Health. Copyright © 2016 Elsevier Ltd. All rights reserved.
The effect of image processing on the detection of cancers in digital mammography.
Warren, Lucy M; Given-Wilson, Rosalind M; Wallis, Matthew G; Cooke, Julie; Halling-Brown, Mark D; Mackenzie, Alistair; Chakraborty, Dev P; Bosmans, Hilde; Dance, David R; Young, Kenneth C
2014-08-01
OBJECTIVE. The objective of our study was to investigate the effect of image processing on the detection of cancers in digital mammography images. MATERIALS AND METHODS. Two hundred seventy pairs of breast images (both breasts, one view) were collected from eight systems using Hologic amorphous selenium detectors: 80 image pairs showed breasts containing subtle malignant masses; 30 image pairs, biopsy-proven benign lesions; 80 image pairs, simulated calcification clusters; and 80 image pairs, no cancer (normal). The 270 image pairs were processed with three types of image processing: standard (full enhancement), low contrast (intermediate enhancement), and pseudo-film-screen (no enhancement). Seven experienced observers inspected the images, locating and rating regions they suspected to be cancer for likelihood of malignancy. The results were analyzed using a jackknife-alternative free-response receiver operating characteristic (JAFROC) analysis. RESULTS. The detection of calcification clusters was significantly affected by the type of image processing: The JAFROC figure of merit (FOM) decreased from 0.65 with standard image processing to 0.63 with low-contrast image processing (p = 0.04) and from 0.65 with standard image processing to 0.61 with film-screen image processing (p = 0.0005). The detection of noncalcification cancers was not significantly different among the image-processing types investigated (p > 0.40). CONCLUSION. These results suggest that image processing has a significant impact on the detection of calcification clusters in digital mammography. For the three image-processing versions and the system investigated, standard image processing was optimal for the detection of calcification clusters. The effect on cancer detection should be considered when selecting the type of image processing in the future.
Alternative Fuels Research Laboratory
NASA Technical Reports Server (NTRS)
Surgenor, Angela D.; Klettlinger, Jennifer L.; Nakley, Leah M.; Yen, Chia H.
2012-01-01
NASA Glenn has invested over $1.5 million in engineering, and infrastructure upgrades to renovate an existing test facility at the NASA Glenn Research Center (GRC), which is now being used as an Alternative Fuels Laboratory. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch (F-T) synthesis and thermal stability testing. This effort is supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing project. The purpose of this test facility is to conduct bench scale F-T catalyst screening experiments. These experiments require the use of a synthesis gas feedstock, which will enable the investigation of F-T reaction kinetics, product yields and hydrocarbon distributions. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor for catalyst activation studies. Product gas composition and performance data can be continuously obtained with an automated gas sampling system, which directly connects the reactors to a micro-gas chromatograph (micro GC). Liquid and molten product samples are collected intermittently and are analyzed by injecting as a diluted sample into designated gas chromatograph units. The test facility also has the capability of performing thermal stability experiments of alternative aviation fuels with the use of a Hot Liquid Process Simulator (HLPS) (Ref. 1) in accordance to ASTM D 3241 "Thermal Oxidation Stability of Aviation Fuels" (JFTOT method) (Ref. 2). An Ellipsometer will be used to study fuel fouling thicknesses on heated tubes from the HLPS experiments. A detailed overview of the test facility systems and capabilities are described in this paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, K.K.; Collins, J.L.; Hunt, R.D.
1999-02-01
The Department of Energy (DOE) is required by law to treat and safely dispose of the radioactive wastes from its nuclear weapon production activities. The primary radionuclide in the DOE liquid wastes or supernatants is {sup 137}Cs. At the Savannah River Site (SRS), the In-Tank Precipitation (ITP) process was selected as the baseline technology to remove {sup 137}Cs from the supernatants, which are stored in underground storage tanks. In the ITP process, tetraphenylborate reacts with the water-soluble cesium to form a precipitant. The treated supernatant can then be immobilized in grout or saltstone and stored in vaults at the SRS.more » However, problems were encountered during the full-scale ITP processing. These difficulties have led to the evaluation of alternative technologies and/or concepts to the currently configured ITP process. The High-Level Waste Salt Disposition Team at the SRS is currently performing this assessment. After an initial screening of all potential alternatives, the Salt Disposition Team selected four primary options to evaluate further before the final down-selection. Crystalline silicotitanate (CST), an inorganic ion exchanger, was chosen as one of the leading alternatives. Since nearly all of the CST tests have been performed on supernatants from Hanford and Oak Ridge, the Salt Disposition Team has requested that personnel at the SRS and Oak Ridge National Laboratory (ORNL) determine the performance of the engineered form of CST, IONSIV{reg_sign} IE-911, with actual and simulated SRS supernatants.« less
Rychetnik, Lucie; Doust, Jenny; Thomas, Rae; Gardiner, Robert; MacKenzie, Geraldine; Glasziou, Paul
2014-01-01
Objective Cancer screening policies and programmes should take account of public values and concerns. This study sought to determine the priorities, values and concerns of men who were ‘fully informed’ about the benefits and harms of prostate-specific antigen (PSA) screening; and empirically examine the value of a community jury in eliciting public values on PSA screening. Setting Community jury was convened on the Gold Coast, Queensland (Australia) to consider PSA screening benefits and harms, and whether government campaigns on PSA screening should be conducted. Participants 27 men (volunteers) aged 50–70 with no personal history of prostate cancer and willing to attend jury 6–7 April 2013: 12 were randomly allocated to jury (11 attended). Outcome measures A qualitative analysis was conducted of the jury deliberations (audio-recorded and transcribed) to elicit the jury's views and recommendations. A survey determined the impact of the jury process on participants’ individual testing decisions compared with control group. Results The jury concluded governments should not invest in programmes focused on PSA screening directed at the public because the PSA test did not offer sufficient reassurance or benefit and could raise unnecessary alarm. It recommended an alternative programme to support general practitioners to provide patients with better quality and more consistent information about PSA screening. After the jury, participants were less likely to be tested in the future compared with the controls, but around half said they would still consider doing so. Conclusions The jury's unanimous verdict about government programmes was notable in the light of their divergent views on whether or not they would be screened themselves in the future. Community juries provide valuable insights into the priorities and concerns of men weighing up the benefits and harms of PSA screening. It will be important to assess the degree to which the findings are generalisable to other settings. PMID:24785399
Nshimyumukiza, Léon; Durand, Audrey; Gagnon, Mathieu; Douville, Xavier; Morin, Suzanne; Lindsay, Carmen; Duplantie, Julie; Gagné, Christian; Jean, Sonia; Giguère, Yves; Dodin, Sylvie; Rousseau, François; Reinharz, Daniel
2013-01-01
A patient-level Markov decision model was used to simulate a virtual cohort of 500,000 women 40 years old and over, in relation to osteoporosis-related hip, clinical vertebral, and wrist bone fractures events. Sixteen different screening options of three main scenario groups were compared: (1) the status quo (no specific national prevention program); (2) a universal primary prevention program; and (3) a universal screening and treatment program based on the 10-year absolute risk of fracture. The outcomes measured were total directs costs from the perspective of the public health care system, number of fractures, and quality-adjusted life-years (QALYs). Results show that an option consisting of a program promoting physical activity and treatment if a fracture occurs is the most cost-effective (CE) (cost/fracture averted) alternative and also the only cost saving one, especially for women 40 to 64 years old. In women who are 65 years and over, bone mineral density (BMD)-based screening and treatment based on the 10-year absolute fracture risk calculated using a Canadian Association of Radiologists and Osteoporosis Canada (CAROC) tool is the best next alternative. In terms of cost-utility (CU), results were similar. For women less than 65 years old, a program promoting physical activity emerged as cost-saving but BMD-based screening with pharmacological treatment also emerged as an interesting alternative. In conclusion, a program promoting physical activity is the most CE and CU option for women 40 to 64 years old. BMD screening and pharmacological treatment might be considered a reasonable alternative for women 65 years old and over because at a healthcare capacity of $50,000 Canadian dollars ($CAD) for each additional fracture averted or for one QALY gained its probabilities of cost-effectiveness compared to the program promoting physical activity are 63% and 75%, respectively, which could be considered socially acceptable. Consideration of the indirect costs could change these findings. PMID:22991210
DOE Office of Scientific and Technical Information (OSTI.GOV)
DOE /NV
This Corrective Action Decision Document has been prepared for Corrective Action Unit 340, the NTS Pesticide Release Sites, in accordance with the Federal Facility Agreement and Consent Order of 1996 (FFACO, 1996). Corrective Action Unit 340 is located at the Nevada Test Site, Nevada, and is comprised of the following Corrective Action Sites: 23-21-01, Area 23 Quonset Hut 800 Pesticide Release Ditch; 23-18-03, Area 23 Skid Huts Pesticide Storage; and 15-18-02, Area 15 Quonset Hut 15-11 Pesticide Storage. The purpose of this Corrective Action Decision Document is to identify and provide a rationale for the selection of a recommended correctivemore » action alternative for each Corrective Action Site. The scope of this Corrective Action Decision Document consists of the following tasks: Develop corrective action objectives; Identify corrective action alternative screening criteria; Develop corrective action alternatives; Perform detailed and comparative evaluations of the corrective action alternatives in relation to the corrective action objectives and screening criteria; and Recommend and justify a preferred corrective action alternative for each Corrective Action Site.« less
Chaikuad, Apirat; Knapp, Stefan; von Delft, Frank
2015-01-01
The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant. PMID:26249344
Chaikuad, Apirat; Knapp, Stefan; von Delft, Frank
2015-08-01
The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.
Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer
NASA Astrophysics Data System (ADS)
Gran, R.; Betancourt, M.; Elkins, M.; Rodrigues, P. A.; Akbar, F.; Aliaga, L.; Andrade, D. A.; Bashyal, A.; Bellantoni, L.; Bercellie, A.; Bodek, A.; Bravar, A.; Budd, H.; Vera, G. F. R. Caceres; Cai, T.; Carneiro, M. F.; Coplowe, D.; da Motta, H.; Dytman, S. A.; Díaz, G. A.; Felix, J.; Fields, L.; Fine, R.; Gallagher, H.; Ghosh, A.; Haider, H.; Han, J. Y.; Harris, D. A.; Henry, S.; Jena, D.; Kleykamp, J.; Kordosky, M.; Le, T.; Leistico, J. R.; Lovlein, A.; Lu, X.-G.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; McFarland, K. S.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Nguyen, C.; Norrick, A.; Nuruzzaman, Olivier, A.; Paolone, V.; Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Ren, L.; Rimal, D.; Ruterbories, D.; Schellman, H.; Salinas, C. J. Solano; Su, H.; Sultana, M.; Falero, S. Sánchez; Valencia, E.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; Minerva Collaboration
2018-06-01
We report on multinucleon effects in low momentum transfer (<0.8 GeV /c ) antineutrino interactions on plastic (CH) scintillator. These data are from the 2010-2011 antineutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well described when a screening effect at a low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasielastic, Δ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this antineutrino sample. We present the results as a double-differential cross section to accelerate the investigation of alternate models for antineutrino scattering off nuclei.
Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer.
Gran, R; Betancourt, M; Elkins, M; Rodrigues, P A; Akbar, F; Aliaga, L; Andrade, D A; Bashyal, A; Bellantoni, L; Bercellie, A; Bodek, A; Bravar, A; Budd, H; Vera, G F R Caceres; Cai, T; Carneiro, M F; Coplowe, D; da Motta, H; Dytman, S A; Díaz, G A; Felix, J; Fields, L; Fine, R; Gallagher, H; Ghosh, A; Haider, H; Han, J Y; Harris, D A; Henry, S; Jena, D; Kleykamp, J; Kordosky, M; Le, T; Leistico, J R; Lovlein, A; Lu, X-G; Maher, E; Manly, S; Mann, W A; Marshall, C M; McFarland, K S; McGowan, A M; Messerly, B; Miller, J; Mislivec, A; Morfín, J G; Mousseau, J; Naples, D; Nelson, J K; Nguyen, C; Norrick, A; Nuruzzaman; Olivier, A; Paolone, V; Patrick, C E; Perdue, G N; Ramírez, M A; Ransome, R D; Ray, H; Ren, L; Rimal, D; Ruterbories, D; Schellman, H; Salinas, C J Solano; Su, H; Sultana, M; Falero, S Sánchez; Valencia, E; Wolcott, J; Wospakrik, M; Yaeggy, B
2018-06-01
We report on multinucleon effects in low momentum transfer (<0.8 GeV/c) antineutrino interactions on plastic (CH) scintillator. These data are from the 2010-2011 antineutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well described when a screening effect at a low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasielastic, Δ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this antineutrino sample. We present the results as a double-differential cross section to accelerate the investigation of alternate models for antineutrino scattering off nuclei.
Clinical Validity of hearScreen™ Smartphone Hearing Screening for School Children.
Mahomed-Asmail, Faheema; Swanepoel, De Wet; Eikelboom, Robert H; Myburgh, Hermanus C; Hall, James
2016-01-01
The study aimed to determine the validity of a smartphone hearing screening technology (hearScreen™) compared with conventional screening audiometry in terms of (1) sensitivity and specificity, (2) referral rate, and (3) test time. One thousand and seventy school-age children in grades 1 to 3 (8 ± 1.1 average years) were recruited from five public schools. Children were screened twice, once using conventional audiometry and once with the smartphone hearing screening. Screening was conducted in a counterbalanced sequence, alternating initial screen between conventional or smartphone hearing screening. No statistically significant difference in performance between techniques was noted, with smartphone screening demonstrating equivalent sensitivity (75.0%) and specificity (98.5%) to conventional screening audiometry. While referral rates were lower with the smartphone screening (3.2 vs. 4.6%), it was not significantly different (p > 0.05). Smartphone screening (hearScreen™) was 12.3% faster than conventional screening. Smartphone hearing screening using the hearScreen™ application is accurate and time efficient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sansone, M.J.
1979-02-01
On the basis of simple, first approximation calculations, it has been shown that catalytic gasification and hydrogasification are inherently superior to conventional gasification with respect to carbon utilization and thermal efficiency. However, most processes which are directed toward the production of substitute natural gas (SNG) by direct combination of coal with steam at low temperatures (catalytic processes) or with hydrogen (hydrogasification) will require a step for separation of product SNG from a recycle stream. The success or falure of the process could well depend upon the economics of this separation scheme. The energetics for the separation of mixtures of idealmore » gases has been considered in some detail. Minimum energies for complete separation of representative effluent mixtures have been calculated as well as energies for separation into product and recycle streams. The gas mixtures include binary systems of H/sub 2/ and CH/sub 4/ and ternary mixtures of H/sub 2/, CH/sub 4/, and CO. A brief summary of a number of different real separation schemes has also been included. We have arbitrarily divided these into five categories: liquefaction, absorption, adsorption, chemical, and diffusional methods. These separation methods will be screened and the more promising methods examined in more detail in later reports. Finally, a brief mention of alternative coal conversion processes concludes this report.« less
Rapid screening of guar gum using portable Raman spectral identification methods.
Srivastava, Hirsch K; Wolfgang, Steven; Rodriguez, Jason D
2016-01-25
Guar gum is a well-known inactive ingredient (excipient) used in a variety of oral pharmaceutical dosage forms as a thickener and stabilizer of suspensions and as a binder of powders. It is also widely used as a food ingredient in which case alternatives with similar properties, including chemically similar gums, are readily available. Recent supply shortages and price fluctuations have caused guar gum to come under increasing scrutiny for possible adulteration by substitution of cheaper alternatives. One way that the U.S. FDA is attempting to screen pharmaceutical ingredients at risk for adulteration or substitution is through field-deployable spectroscopic screening. Here we report a comprehensive approach to evaluate two field-deployable Raman methods--spectral correlation and principal component analysis--to differentiate guar gum from other gums. We report a comparison of the sensitivity of the spectroscopic screening methods with current compendial identification tests. The ability of the spectroscopic methods to perform unambiguous identification of guar gum compared to other gums makes them an enhanced surveillance alternative to the current compendial identification tests, which are largely subjective in nature. Our findings indicate that Raman spectral identification methods perform better than compendial identification methods and are able to distinguish guar gum from other gums with 100% accuracy for samples tested by spectral correlation and principal component analysis. Published by Elsevier B.V.
Hwang, Jessica P; Roundtree, Aimee K; Suarez-Almazor, Maria E
2012-10-01
We explored attitudes about prevention, screening and treatment of hepatitis B virus (HBV) infection in Chinese, Korean and Vietnamese communities. We use qualitative methods in 12 focus groups (n = 113) of adults who self-reported their ethnicity to be Chinese, Korean, or Vietnamese. We use grounded theory (i.e., consensus-building between co-coders about recurring, emerging themes) for analysis. Diet, nutrition, fatigue and stress were misidentified as HBV causes. Improving hygiene, diet, exercise, and holistic methods were misidentified as viable HBV prevention methods. Common screening problems included not affording test and not understanding test results. Participants shared reasons for using complementary and alternative medicine--when Western medicine fails or becomes unaffordable. Participants sought information from medical providers and fellow community members, but also from the internet. Many of the attitudes and opinions that emerged may deter participation in HBV screening, prevention and treatment, insofar as community members may factor them into healthcare decision-making, choose alternative but ineffective methods of prevention and treatment, and undervalue the benefits of screening. More patient education in both traditional and new media is necessary for clarifying transmission, screening and treatment misunderstandings.
Hwang, Jessica P.; Roundtree, Aimee K.; Suarez-Almazor, Maria E.
2017-01-01
Objectives We explored attitudes about prevention, screening and treatment of hepatitis B virus (HBV) infection in Chinese, Korean and Vietnamese communities. Methods We use qualitative methods in 12 focus groups (n=113) of adults who self-reported their ethnicity to be Chinese, Korean, or Vietnamese. We use grounded theory (i.e., consensus-building between co-coders about recurring, emerging themes) for analysis. Results Diet, nutrition, fatigue and stress were misidentified as HBV causes. Improving hygiene, diet, exercise, and holistic methods were misidentified as viable HBV prevention methods. Common screening problems included not affording test and not understanding test results. Participants shared reasons for using complementary and alternative medicine—when Western medicine fails or becomes unaffordable. Participants sought information from medical providers and fellow community members, but also from the internet. Conclusions Many of the attitudes and opinions that emerged may deter participation in HBV screening, prevention and treatment, insofar as community members may factor them into healthcare decision-making, choose alternative but ineffective methods of prevention and treatment, and undervalue the benefits of screening. More patient education in both traditional and new media is necessary for clarifying transmission, screening and treatment misunderstandings. PMID:22302653
HCFA and the states: politics and intergovernmental leverage.
Gormley, W T; Boccuti, C
2001-06-01
In this article, we seek to explain variations in the Health Care Financing Administration's (HCFA) relationship to state governments. After reviewing several alternative models of the policy-making process, we argue that the utility of each model depends on certain issue characteristics, especially salience and conflict. We further argue that HCFA's choice of intergovernmental tools, rooted in a political setting, depends on the same issue characteristics. We illustrate our arguments by examining HCFA's behavior during the Clinton administration and by focusing on four cases: HMO performance measurement, nursing home regulation, lead screening for children, and the Children's Health Insurance Program (CHIP).
Hunter, Sara A; Morris, Colleen; Nelson, Karl; Snyder, Brandon J; Poulton, Thomas B
2017-05-01
The purpose of this study was to determine whether digital breast tomosynthesis (DBT) is a cost-effective alternative to full-field digital mammography (FFDM) for both Medicare and privately insured patients undergoing screening mammography. A retrospective data analysis was performed between July 15, 2013, and July 14, 2014, with data on women presenting for screening mammography that included any additional radiologic workup (n = 6319). Patients chose to undergo DBT or FFDM on the basis of personal preference, physician suggestion, and cost difference. The summation of findings over the 1-year period were used to calculate recall rates, cancer detection rates, and billing costs for a regional private insurer and Medicare. Data from the 6319 patients who participated were divided: 3655 patients underwent DBT, and 2664 underwent FFDM during the year of screening. Private insurance billing cost $2.9 million, and Medicare cost $1.2 million for screening, follow-up imaging, and radiologic procedures. Per-person costs were approximately $40 higher for the DBT group using both forms of insurance. However, cost per cancer detected was lower in the DBT group for both private and governmental insurance, leading to potentially $3.7 million and $899,000 saved per 100 cancers found. After standardization of the difference in cancer detection rates between the two groups, DBT was a cost-equivalent alternative to FFDM for private insurance billing but was a cost-inefficient alternative with respect to Medicare costs. In a community-based setting, DBT is a cost-equivalent or potentially cost-effective alternative to FFDM and has the capacity for improving cancer detection and recall rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W. II; Mabrey, J.B.
1994-07-01
This report presents potential screening benchmarks for protection of aquatic life from contaminants in water. Because there is no guidance for screening benchmarks, a set of alternative benchmarks is presented herein. The alternative benchmarks are based on different conceptual approaches to estimating concentrations causing significant effects. For the upper screening benchmark, there are the acute National Ambient Water Quality Criteria (NAWQC) and the Secondary Acute Values (SAV). The SAV concentrations are values estimated with 80% confidence not to exceed the unknown acute NAWQC for those chemicals with no NAWQC. The alternative chronic benchmarks are the chronic NAWQC, the Secondary Chronicmore » Value (SCV), the lowest chronic values for fish and daphnids from chronic toxicity tests, the estimated EC20 for a sensitive species, and the concentration estimated to cause a 20% reduction in the recruit abundance of largemouth bass. It is recommended that ambient chemical concentrations be compared to all of these benchmarks. If NAWQC are exceeded, the chemicals must be contaminants of concern because the NAWQC are applicable or relevant and appropriate requirements (ARARs). If NAWQC are not exceeded, but other benchmarks are, contaminants should be selected on the basis of the number of benchmarks exceeded and the conservatism of the particular benchmark values, as discussed in the text. To the extent that toxicity data are available, this report presents the alternative benchmarks for chemicals that have been detected on the Oak Ridge Reservation. It also presents the data used to calculate benchmarks and the sources of the data. It compares the benchmarks and discusses their relative conservatism and utility.« less
Evaluation of Intraosseous Fluid as an Alternative Biological Specimen in Postmortem Toxicology.
Rodda, Luke N; Volk, Justin A; Moffat, Ellen; Williams, Chinyere M; Lynch, Kara L; Wu, Alan H B
2018-04-01
The postmortem redistribution phenomenon is an important factor in the interpretation of blood drug concentrations as a cause or factor in death. Intraosseous fluid (IOF) may serve as an alternative matrix for drug testing. Intraosseous fluid was collected from the left and right tibias and humerus of 29 decedents using the Arrow EZ-IO Intraosseous Vascular Access System. Standard autopsy specimens including blood were also collected at the same time during autopsy. Blood and IOF specimens were screened by immunoassay for opioids, fentanyl analogs, oxycodone, methadone, cocaine, methamphetamine, amphetamines, phencyclidine, tricyclic antidepressants, benzodiazepines and cannabinoids, using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Correlation between cardiac/central blood ELISA and IOF ELISA results was mostly 100% for drug targets. Further blood confirmation analysis was performed by gas chromatography mass spectrometry also showed comparable correlation to IOF screen results. There was no significant difference between the IOF sites or sides of the body. This novel study supports the use of IOF as an alternative postmortem specimen for toxicological investigations as a potentially less-compromised tissue in decomposed or traumatized bodies. Preliminary data is provided for the screening of common drugs of abuse in IOF that may show to be subject to alternative rates of postmortem redistribution than to that of other biological specimens in future studies that quantitate IOF drug concentrations.
A Method for Identifying Small-Molecule Aggregators Using Photonic Crystal Biosensor Microplates
Chan, Leo L.; Lidstone, Erich A.; Finch, Kristin E.; Heeres, James T.; Hergenrother, Paul J.; Cunningham, Brian T.
2010-01-01
Small molecules identified through high-throughput screens are an essential element in pharmaceutical discovery programs. It is now recognized that a substantial fraction of small molecules exhibit aggregating behavior leading to false positive results in many screening assays, typically due to nonspecific attachment to target proteins. Therefore, the ability to efficiently identify compounds within a screening library that aggregate can streamline the screening process by eliminating unsuitable molecules from further consideration. In this work, we show that photonic crystal (PC) optical biosensor microplate technology can be used to identify and quantify small-molecule aggregation. A group of aggregators and nonaggregators were tested using the PC technology, and measurements were compared with those gathered by three alternative methods: dynamic light scattering (DLS), an α-chymotrypsin colorimetric assay, and scanning electron microscopy (SEM). The PC biosensor measurements of aggregation were confirmed by visual observation using SEM, and were in general agreement with the α-chymotrypsin assay. DLS measurements, in contrast, demonstrated inconsistent readings for many compounds that are found to form aggregates in shapes, very different from the classical spherical particles assumed in DLS modeling. As a label-free detection method, the PC biosensor aggregation assay is simple to implement and provides a quantitative direct measurement of the mass density of material adsorbed to the transducer surface, whereas the microplate-based sensor format enables compatibility with high-throughput automated liquid-handling methods used in pharmaceutical screening. PMID:20930952
Bogavac-Stanojević, Natasa; Dopsaj, Violeta; Jelić-Ivanović, Zorana; Lakić, Dragana; Vasić, Dragan; Petrova, Guenka
2013-01-01
We examined the cost-effectiveness of the three different D-dimer measurements in the screening of DVT in models with and without calculation of pre-test probability (PTP) score. Moreover, we calculated the minimal cost in DVT detection. In the group of 192 patients with clinically suspected acute DVT, we examined the three different D-dimer measurements (Innovance D-dimer, Hemosil D-dimer HS and Vidas D-dimer Exclusion II) in combination with and without PTP assessment. The diagnostic alternative employing Vidas D-dimer Exclusion II assay without and with PTP calculation gave lower incremental cost-effectiveness ratio (ICER) than the alternative employing Hemosil D-dimer HS assay (0.187 Euros vs. 0.998 Euros per one additional DVT positive patient selected for CUS in model without PTP assessment and 0.450 vs. 0.753 Euros per one DVT positive patient selected for CUS in model with PTP assessment). According to sensitivity analysis, the Hemosil D-dimer HS assay was the most cost effective alternative when one patient was admitted to the vascular ambulance per day. Vidas D-dimer Exclusion II assay was the most cost effective alternative when more than one patient were admitted to the vascular ambulance per day. Cost minimisation analysis indicated that selection of patients according to PTP score followed by D-dimer analysis decreases the cost of DVT diagnosis. ICER analysis enables laboratories to choose optimal laboratory tests according to number of patients admitted to laboratory. Results support the feasibility of using PTP scoring and D-dimer measurement before CUS examination in DVT screening.
Quantitative screening of yeast surface-displayed polypeptide libraries by magnetic bead capture.
Yeung, Yik A; Wittrup, K Dane
2002-01-01
Magnetic bead capture is demonstrated here to be a feasible alternative for quantitative screening of favorable mutants from a cell-displayed polypeptide library. Flow cytometric sorting with fluorescent probes has been employed previously for high throughput screening for either novel binders or improved mutants. However, many laboratories do not have ready access to this technology as a result of the limited availability and high cost of cytometers, restricting the use of cell-displayed libraries. Using streptavidin-coated magnetic beads and biotinylated ligands, an alternative approach to cell-based library screening for improved mutants was developed. Magnetic bead capture probability of labeled cells is shown to be closely correlated with the surface ligand density. A single-pass enrichment ratio of 9400 +/- 1800-fold, at the expense of 85 +/- 6% binder losses, is achieved from screening a library that contains one antibody-displaying cell (binder) in 1.1 x 10(5) nondisplaying cells. Additionally, kinetic screening for an initial high affinity to low affinity (7.7-fold lower) mutant ratio of 1:95,000, the magnetic bead capture method attains a single-pass enrichment ratio of 600 +/- 200-fold with a 75 +/- 24% probability of loss for the higher affinity mutant. The observed high loss probabilities can be straightforwardly compensated for by library oversampling, given the inherently parallel nature of the screen. Overall, these results demonstrate that magnetic beads are capable of quantitatively screening for novel binders and improved mutants. The described methods are directly analogous to procedures in common use for phage display and should lower the barriers to entry for use of cell surface display libraries.
Varughese, Anna M; Hagerman, Nancy; Townsend, Mari E
2013-07-01
The anesthesia preoperative screening and evaluation of a patient prior to surgery is a critical element in the safe and effective delivery of anesthesia care. In this era of increased focus on cost containment, many anesthesia practices are looking for ways to maximize productivity while maintaining the quality of the preoperative evaluation process by harnessing and optimizing all available resources. We sought to develop a Nurse Practitioner-assisted Preoperative Anesthesia Screening process using quality improvement methods with the goal of maintaining the quality of the screening process, while at the same time redirecting anesthesiologists time for the provision of nonoperating room (OR) anesthesia. The Nurse practitioner (NP) time (approximately 10 h per week) directed to this project was gained as a result of an earlier resource utilization improvement project within the Department of Anesthesia. The goal of this improvement project was to increase the proportion of patient anesthesia screens conducted by NPs to 50% within 6 months. After discussion with key stakeholders of the process, a multidisciplinary improvement team identified a set of operational factors (key drivers) believed to be important to the success of the preoperative anesthesia screening process. These included the development of dedicated NP time for daily screening, NP competency and confidence with the screening process, effective mentoring by anesthesiologists, standardization of screening process, and communication with stakeholders of the process, that is, surgeons. These key drivers focused on the development of several interventions such as (i) NP education in the preoperative anesthesia screening for consultation process by a series of didactic lectures conducted by anesthesiologists, and NP's shadowing an anesthesiologist during the screening process, (ii) Anesthesiologist mentoring and assessment of NP screenings using the dual screening process whereby both anesthesiologists and NP conducted the screening process independently and results were compared and discussed, (iii) Examination and re-adjustment of NP schedules to provide time for daily screening while preserving other responsibilities, and (iv) Standardization through the development of guidelines for the preoperative screening process. Measures recorded included the percentage of patient anesthesia screens conducted by NP, the percentage of dual screens with MD and NP agreement regarding the screening decision, and the average times taken for the anesthesiologist and NP screening process. After implementation of these interventions, the percentage of successful NP-assisted anesthesia consultation screenings increased from 0% to 65% over a period of 6 months. The Anesthesiologists' time redirected to non-OR anesthesia averaged at least 8 h a week. The percentage of dual screens with agreement on the screening decision was 96% (goal >95%). The overall average time taken for a NP screen was 8.2 min vs 4.5 min for an anesthesiologist screen. The overall average operating room delays and cancelations for cases on the day of surgery remained the same. By applying quality improvement methods, we identified key drivers for the institution of an NP-assisted preoperative screening process and successfully implemented this process while redirecting anesthesiologists' time for the provision of non-OR anesthesia. This project was instrumental in improving the matching of provider skills with clinical need while maintaining superior outcomes at the lowest possible cost. © 2013 John Wiley & Sons Ltd.
Cervical cancer screening programs in Latin America and the Caribbean.
Murillo, Raul; Almonte, Maribel; Pereira, Ana; Ferrer, Elena; Gamboa, Oscar A; Jerónimo, José; Lazcano-Ponce, Eduardo
2008-08-19
Latin America and the Caribbean (LAC) have a significant burden of cervical cancer. Prophylactic human papillomavirus (HPV) vaccines are an opportunity for primary prevention and new screening methods, such as new HPV DNA testing, are promising alternatives to cytology screening that should be analyzed in the context of regional preventive programs. Cytology-based screening programs have not fulfilled their expectations and coverage does not sufficiently explain the lack of impact on screening in LAC. While improved evaluation of screening programs is necessary to increase the impact of screening on the reduction of incidence and mortality, other programmatic aspects will need to be addressed such as follow-up of positive tests and quality control. The implementation of new technologies might enhance screening performance and reduce mortality in the region. The characteristics, performance and impact of cervical cancer screening programs in LAC are reviewed in this article.
Evaluation of a Noncontact, Alternative Mosquito Repellent Assay System.
Tisgratog, Rungarun; Kongmee, Monthathip; Sanguanpong, Unchalee; Prabaripai, Atchariya; Bangs, Michael J; Chareonviriyaphap, Theeraphap
2016-09-01
A novel noncontact repellency assay system (NCRAS) was designed and evaluated as a possible alternative method for testing compounds that repel or inhibit mosquitoes from blood feeding. Deet and Aedes aegypti were used in a controlled laboratory setting. Using 2 study designs, a highly significant difference were seen between deet-treated and untreated skin placed behind the protective screens, indicating that deet was detected and was acting as a deterrence to mosquito landing and probing behavior. However, a 2nd study showed significant differences between protected (behind a metal screen barrier) and unprotected (exposed) deet-treated forearms, indicating the screen mesh might restrict the detection of deet and thus influences landing/biting response. These findings indicate the prototype NCRAS shows good promise but requires further evaluation and possible modification in design and testing protocol to achieve more desirable operational attributes in comparison with direct skin-contact repellency mosquito assays.
We are evaluating methods to screen/prioritize large numbers of chemicals using 6 day old zebrafish (Danio rerio) as an alternative model for detecting neurotoxic effects. Our behavioral testing paradigm simultaneously tests individual larval zebrafish under sequential light and...
The U.S. Environmental Protection Agency is evaluating methods to screen and prioritize large numbers of chemicals using 6 day old zebrafish (Danio rerio) as an alternative test model for detecting neurotoxic chemicals. We use a behavioral testing paradigm that simultaneously tes...
Due to their toxicity and persistence in the environment, brominated flame retardants (BFRs) are being phased out of commercial use, leading to the increased use of alternative chemicals such as the organophosphorus flame retardants (OPFRs). Due to the structural similarity of th...
One use of alternative methods is to target animal use at only those chemicals and tests that are absolutely necessary. We discuss prioritization of testing based on high-throughput screening assays (HTS), QSAR modeling, high-throughput toxicokinetics (HTTK), and exposure modelin...
Gopal, Hemavathi; Hassan, Hassan K.; Rodríguez-Pérez, Mario A.; Toé, Laurent D.; Lustigman, Sara; Unnasch, Thomas R.
2012-01-01
Background Entomological surveys of Simulium vectors are an important component in the criteria used to determine if Onchocerca volvulus transmission has been interrupted and if focal elimination of the parasite has been achieved. However, because infection in the vector population is quite rare in areas where control has succeeded, large numbers of flies need to be examined to certify transmission interruption. Currently, this is accomplished through PCR pool screening of large numbers of flies. The efficiency of this process is limited by the size of the pools that may be screened, which is in turn determined by the constraints imposed by the biochemistry of the assay. The current method of DNA purification from pools of vector black flies relies upon silica adsorption. This method can be applied to screen pools containing a maximum of 50 individuals (from the Latin American vectors) or 100 individuals (from the African vectors). Methodology/Principal Findings We have evaluated an alternative method of DNA purification for pool screening of black flies which relies upon oligonucleotide capture of Onchocerca volvulus genomic DNA from homogenates prepared from pools of Latin American and African vectors. The oligonucleotide capture assay was shown to reliably detect one O. volvulus infective larva in pools containing 200 African or Latin American flies, representing a two-four fold improvement over the conventional assay. The capture assay requires an equivalent amount of technical time to conduct as the conventional assay, resulting in a two-four fold reduction in labor costs per insect assayed and reduces reagent costs to $3.81 per pool of 200 flies, or less than $0.02 per insect assayed. Conclusions/Significance The oligonucleotide capture assay represents a substantial improvement in the procedure used to detect parasite prevalence in the vector population, a major metric employed in the process of certifying the elimination of onchocerciasis. PMID:22724041
Air impacts from three alternatives for producing JP-8 jet fuel.
Kositkanawuth, Ketwalee; Gangupomu, Roja Haritha; Sattler, Melanie L; Dennis, Brian H; MacDonnell, Frederick M; Billo, Richard; Priest, John W
2012-10-01
To increase U.S. petroleum energy independence, the University of Texas at Arlington (UT Arlington) has developed a direct coal liquefaction process which uses a hydrogenated solvent and a proprietary catalyst to convert lignite coal to crude oil. This sweet crude can be refined to form JP-8 military jet fuel, as well as other end products like gasoline and diesel. This paper presents an analysis of air pollutants resulting from using UT Arlington's liquefaction process to produce crude and then JP-8, compared with 2 alternative processes: conventional crude extraction and refining (CCER), and the Fischer-Tropsch process. For each of the 3 processes, air pollutant emissions through production of JP-8 fuel were considered, including emissions from upstream extraction/ production, transportation, and conversion/refining. Air pollutants from the direct liquefaction process were measured using a LandTEC GEM2000 Plus, Draeger color detector tubes, OhioLumex RA-915 Light Hg Analyzer, and SRI 8610 gas chromatograph with thermal conductivity detector. According to the screening analysis presented here, producing jet fuel from UT Arlington crude results in lower levels of pollutants compared to international conventional crude extraction/refining. Compared to US domestic CCER, the UTA process emits lower levels of CO2-e, NO(x), and Hg, and higher levels of CO and SO2. Emissions from the UT Arlington process for producing JP-8 are estimated to be lower than for the Fischer-Tropsch process for all pollutants, with the exception of CO2-e, which were high for the UT Arlington process due to nitrous oxide emissions from crude refining. When comparing emissions from conventional lignite combustion to produce electricity, versus UT Arlington coal liquefaction to make JP-8 and subsequent JP-8 transport, emissions from the UT Arlington process are estimated to be lower for all air pollutants, per MJ of power delivered to the end user. The United States currently imports two-thirds of its crude oil, leaving its transportation system especially vulnerable to disruptions in international crude supplies. At current use rates, U.S. coal reserves (262 billion short tons, including 23 billion short tons lignite) would last 236 years. Accordingly, the University of Texas at Arlington (UT Arlington) has developed a process that converts lignite to crude oil, at about half the cost of regular crude. According to the screening analysis presented here, producing jet fuel from UT Arlington crude generates lower levels of pollutants compared to international conventional crude extraction/refining (CCER).
Clark, Brian R.; Landon, Matthew K.; Kauffman, Leon J.; Hornberger, George Z.
2008-01-01
Contamination of public-supply wells has resulted in public-health threats and negative economic effects for communities that must treat contaminated water or find alternative water supplies. To investigate factors controlling vulnerability of public-supply wells to anthropogenic and natural contaminants using consistent and systematic data collected in a variety of principal aquifer settings in the United States, a study of Transport of Anthropogenic and Natural Contaminants to public-supply wells was begun in 2001 as part of the U.S. Geological Survey National Water-Quality Assessment Program. The area simulated by the ground-water flow model described in this report was selected for a study of processes influencing contaminant distribution and transport along the direction of ground-water flow towards a public-supply well in southeastern York, Nebraska. Ground-water flow is simulated for a 60-year period from September 1, 1944, to August 31, 2004. Steady-state conditions are simulated prior to September 1, 1944, and represent conditions prior to use of ground water for irrigation. Irrigation, municipal, and industrial wells were simulated using the Multi-Node Well package of the modular three-dimensional ground-water flow model code, MODFLOW-2000, which allows simulation of flow and solutes through wells that are simulated in multiple nodes or layers. Ground-water flow, age, and transport of selected tracers were simulated using the Ground-Water Transport process of MODFLOW-2000. Simulated ground-water age was compared to interpreted ground-water age in six monitoring wells in the unconfined aquifer. The tracer chlorofluorocarbon-11 was simulated directly using Ground-Water Transport for comparison with concentrations measured in six monitoring wells and one public supply well screened in the upper confined aquifer. Three alternative model simulations indicate that simulation results are highly sensitive to the distribution of multilayer well bores where leakage can occur and that the calibrated model resulted in smaller differences than the alternative models between simulated and interpreted ages and measured tracer concentrations in most, but not all, wells. Results of the first alternative model indicate that the distribution of young water in the upper confined aquifer is substantially different when well-bore leakage at known abandoned wells and test holes is removed from the model. In the second alternative model, simulated age near the bottom of the unconfined aquifer was younger than interpreted ages and simulated chlorofluorocarbon-11 concentrations in the upper confined aquifer were zero in five out of six wells because the conventional Well Package fails to account for flow between model layers though well bores. The third alternative model produced differences between simulated and interpreted ground-water ages and measured chlorofluorocarbon-11 concentrations that were comparable to the calibrated model. However, simulated hydraulic heads deviated from measured hydraulic heads by a greater amount than for the calibrated model. Even so, because the third alternative model simulates steady-state flow, additional analysis was possible using steady-state particle tracking to assess the contributing recharge area to a public supply well selected for analysis of factors contributing to well vulnerability. Results from particle-tracking software (MODPATH) using the third alternative model indicates that the contributing recharge area of the study public-supply well is a composite of elongated, seemingly isolated areas associated with wells that are screened in multiple aquifers. The simulated age distribution of particles at the study public-supply well indicates that all water younger than 58 years travels through well bores of wells screened in multiple aquifers. The age distribution from the steady-state model using MODPATH estimates the youngest 7 percent of the water to have a flow-weighted mean age
Use of unbalanced laminates as a screening method for microcracking
NASA Technical Reports Server (NTRS)
Papadopoulos, Demetrios S.; Bowles, Kenneth J.
1990-01-01
State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.
NASA Astrophysics Data System (ADS)
Lam, Carl
Due to technology proliferation, the environmental burden attributed to the production, use, and disposal of hazardous materials in electronics have become a worldwide concern. The major theme of this dissertation is to develop and apply hazardous materials assessment tools to systematically guide pollution prevention opportunities in the context of electronic product design, manufacturing and end-of-life waste management. To this extent, a comprehensive review is first provided on describing hazard traits and current assessment methods to evaluate hazardous materials. As a case study at the manufacturing level, life cycle impact assessment (LCIA)-based and risk-based screening methods are used to quantify chemical and geographic environmental impacts in the U.S. printed wiring board (PWB) industry. Results from this industrial assessment clarify priority waste streams and States to most effectively mitigate impact. With further knowledge of PWB manufacturing processes, select alternative chemical processes (e.g., spent copper etchant recovery) and material options (e.g., lead-free etch resist) are discussed. In addition, an investigation on technology transition effects for computers and televisions in the U.S. market is performed by linking dynamic materials flow and environmental assessment models. The analysis forecasts quantities of waste units generated and maps shifts in environmental impact potentials associated with metal composition changes due to product substitutions. This insight is important to understand the timing and waste quantities expected and the emerging toxic elements needed to be addressed as a consequence of technology transition. At the product level, electronic utility meter devices are evaluated to eliminate hazardous materials within product components. Development and application of a component Toxic Potential Indicator (TPI) assessment methodology highlights priority components requiring material alternatives. Alternative recommendations are provided and substitute materials such as aluminum alloys for stainless steel and high-density polyethylene for polyvinyl chloride and acrylonitrile-based polymers show promise to meet toxicity reduction, cost, and material functionality requirements. Furthermore, the TPI method, an European Union focused screening tool, is customized to reflect regulated U.S. toxicity parameters. Results show that, although it is possible to adopt U.S. parameters into the TPI method, harmonization of toxicity regulation and standards in various nations and regions is necessary to eliminate inconsistencies during hazard screening of substances used globally. As a whole, the present work helps to assimilate material hazard assessment methods into the larger framework of design for environment strategies so toxics use reduction could be achieved for the development and management of electronics and other consumer goods.
Tuite, Ashleigh R.; Burchell, Ann N.; Fisman, David N.
2014-01-01
Background Syphilis co-infection risk has increased substantially among HIV-infected men who have sex with men (MSM). Frequent screening for syphilis and treatment of men who test positive might be a practical means of controlling the risk of infection and disease sequelae in this population. Purpose We evaluated the cost-effectiveness of strategies that increased the frequency and population coverage of syphilis screening in HIV-infected MSM receiving HIV care, relative to current standard of care. Methods We developed a state-transition microsimulation model of syphilis natural history and medical care in HIV-infected MSM receiving care for HIV. We performed Monte Carlo simulations using input data derived from a large observational cohort in Ontario, Canada, and from published biomedical literature. Simulations compared usual care (57% of the population screened annually) to different combinations of more frequent (3- or 6-monthly) screening and higher coverage (100% screened). We estimated expected disease-specific outcomes, quality-adjusted survival, costs, and cost-effectiveness associated with each strategy from the perspective of a public health care payer. Results Usual care was more costly and less effective than strategies with more frequent or higher coverage screening. Higher coverage strategies (with screening frequency of 3 or 6 months) were expected to be cost-effective based on usually cited willingness-to-pay thresholds. These findings were robust in the face of probabilistic sensitivity analyses, alternate cost-effectiveness thresholds, and alternate assumptions about duration of risk, program characteristics, and management of underlying HIV. Conclusions We project that higher coverage and more frequent syphilis screening of HIV-infected MSM would be a highly cost-effective health intervention, with many potentially viable screening strategies projected to both save costs and improve health when compared to usual care. The baseline requirement for regular blood testing in this group (i.e., for viral load monitoring) makes intensification of syphilis screening appear readily practicable. PMID:24983455
Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gran, R.; Betancourt, M.; Elkins, M.
We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less
Anti-Neutrino Charged-Current Reactions on Scintillator with Low Momentum Transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gran, R.; et al.
2018-03-25
We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less
Anti-Neutrino Charged-Current Reactions on Scintillator with Low Momentum Transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gran, R.; et al.
2018-06-01
We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less
Biotechnological production of gluconic acid: future implications.
Singh, Om V; Kumar, Raj
2007-06-01
Gluconic acid (GA) is a multifunctional carbonic acid regarded as a bulk chemical in the food, feed, beverage, textile, pharmaceutical, and construction industries. The favored production process is submerged fermentation by Aspergillus niger utilizing glucose as a major carbohydrate source, which accompanied product yield of 98%. However, use of GA and its derivatives is currently restricted because of high prices: about US$ 1.20-8.50/kg. Advancements in biotechnology such as screening of microorganisms, immobilization techniques, and modifications in fermentation process for continuous fermentation, including genetic engineering programmes, could lead to cost-effective production of GA. Among alternative carbohydrate sources, sugarcane molasses, grape must show highest GA yield of 95.8%, and banana must may assist reducing the overall cost of GA production. These methodologies would open new markets and increase applications of GA.
Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer
Gran, R.; Betancourt, M.; Elkins, M.; ...
2018-06-01
We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less
Ahern, C H; Shih, Y-C T; Dong, W; Parmigiani, G; Shen, Y
2014-10-14
Magnetic resonance imaging (MRI) is recommended for women at high risk for breast cancer. We evaluated the cost-effectiveness of alternative screening strategies involving MRI. Using a microsimulation model, we generated life histories under different risk profiles, and assessed the impact of screening on quality-adjusted life-years, and lifetime costs, both discounted at 3%. We compared 12 screening strategies combining annual or biennial MRI with mammography and clinical breast examination (CBE) in intervals of 0.5, 1, or 2 years vs without, and reported incremental cost-effectiveness ratios (ICERs). Based on an ICER threshold of $100,000/QALY, the most cost-effective strategy for women at 25% lifetime risk was to stagger MRI and mammography plus CBE every year from age 30 to 74, yielding ICER $58,400 (compared to biennial MRI alone). At 50% lifetime risk and with 70% reduction in MRI cost, the recommended strategy was to stagger MRI and mammography plus CBE every 6 months (ICER=$84,400). At 75% lifetime risk, the recommended strategy is biennial MRI combined with mammography plus CBE every 6 months (ICER=$62,800). The high costs of MRI and its lower specificity are limiting factors for annual screening schedule of MRI, except for women at sufficiently high risk.
Tyagi, Rakesh Kumar
2003-04-01
Although a number of screening methods being used for identifying potential endocrine disruptors have generated a wealth of information, a search for alternative combination of methods is still needed to overcome experimental artefacts. There are no generally accepted or validated screening methods for monitoring and studying impact of environmental endocrine disruptors. Also, no single assay can accurately predict all the deleterious effects of endocrine disruptors. For this reason various environmental protection agencies, mainly European and US, have urged that a battery of tests in current use need to be designed to assess their adequacy in detecting the effects of endocrine disruptors. Some details about endocrine disruptors and screening programs can be found at http://www.epa.gov/scipoly/oscpendo/whatis.htm. Several studies in recent years have used fusion proteins between steroid receptors (estrogen, androgen, progesterone, etc.) and green fluorescent protein (GFP) that can serve as an alternative potent screening method to study intracellular dynamics of receptors in living cells. An approach employing nucleocytoplasmic trafficking of steroid receptors as a parameter in response to potential xenobiotic chemicals in living cells may prove to be promising in terms of being direct, fast, reliable, simple and inexpensive. Copyright 2003 Elsevier Science Ltd.
Mayousse, Céline; Celle, Caroline; Moreau, Eléonore; Mainguet, Jean-François; Carella, Alexandre; Simonato, Jean-Pierre
2013-05-31
Transparent flexible electrodes made of metallic nanowires, and in particular silver nanowires (AgNWs), appear as an extremely promising alternative to transparent conductive oxides for future optoelectronic devices. Though significant progresses have been made the last few years, there is still some room for improvement regarding the synthesis of high quality silver nanowire solutions and fabrication process of high performance electrodes. We show that the commonly used purification process can be greatly simplified through decantation. Using this process it is possible to fabricate flexible electrodes by spray coating with sheet resistance lower than 25 Ω sq⁻¹ at 90% transparency in the visible spectrum. These electrodes were used to fabricate an operative transparent flexible touch screen. To our knowledge this is the first reported AgNW based touch sensor relying on capacitive technology.
Nshimyumukiza, Léon; Durand, Audrey; Gagnon, Mathieu; Douville, Xavier; Morin, Suzanne; Lindsay, Carmen; Duplantie, Julie; Gagné, Christian; Jean, Sonia; Giguère, Yves; Dodin, Sylvie; Rousseau, François; Reinharz, Daniel
2013-02-01
A patient-level Markov decision model was used to simulate a virtual cohort of 500,000 women 40 years old and over, in relation to osteoporosis-related hip, clinical vertebral, and wrist bone fractures events. Sixteen different screening options of three main scenario groups were compared: (1) the status quo (no specific national prevention program); (2) a universal primary prevention program; and (3) a universal screening and treatment program based on the 10-year absolute risk of fracture. The outcomes measured were total directs costs from the perspective of the public health care system, number of fractures, and quality-adjusted life-years (QALYs). Results show that an option consisting of a program promoting physical activity and treatment if a fracture occurs is the most cost-effective (CE) (cost/fracture averted) alternative and also the only cost saving one, especially for women 40 to 64 years old. In women who are 65 years and over, bone mineral density (BMD)-based screening and treatment based on the 10-year absolute fracture risk calculated using a Canadian Association of Radiologists and Osteoporosis Canada (CAROC) tool is the best next alternative. In terms of cost-utility (CU), results were similar. For women less than 65 years old, a program promoting physical activity emerged as cost-saving but BMD-based screening with pharmacological treatment also emerged as an interesting alternative. In conclusion, a program promoting physical activity is the most CE and CU option for women 40 to 64 years old. BMD screening and pharmacological treatment might be considered a reasonable alternative for women 65 years old and over because at a healthcare capacity of $50,000 Canadian dollars ($CAD) for each additional fracture averted or for one QALY gained its probabilities of cost-effectiveness compared to the program promoting physical activity are 63% and 75%, respectively, which could be considered socially acceptable. Consideration of the indirect costs could change these findings. Copyright © 2013 American Society for Bone and Mineral Research.
A Triangulation Method for Identifying Hydrostratigraphic Locations of Well Screens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiteside, T. S.
2015-01-31
A method to identify the hydrostratigraphic location of well screens was developed using triangulation with known locations. This method was applied to all of the monitor wells being used to develop the new GSA groundwater model. Results from this method are closely aligned with those from an alternate method which uses a mesh surface.
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2013 CFR
2013-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2010 CFR
2010-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2011 CFR
2011-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2012 CFR
2012-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
USDA-ARS?s Scientific Manuscript database
The identification of specific genes underlying phenotypic variation of complex traits remains one of the greatest challenges in biology despite having genome sequences and more powerful tools. Most genome-wide screens lack sufficient resolving power as they typically depend on linkage. One altern...
Forkmann, Thomas; Vehren, Thomas; Boecker, Maren; Norra, Christine; Wirtz, Markus; Gauggel, Siegfried
2009-10-01
The Beck Depression Inventory (BDI) is widely used for depression screening in various patient populations. However, there are still insufficient data about its sensitivity and specificity in nonpsychiatric patients. Furthermore, some research suggests that somatic BDI items heighten its sum score artificially in physically ill patients. The aim of the present study was to validate the conventional BDI cut-off score by examination of its sensitivity and specificity in a mixed sample of cardiac inpatients and compare it to a modified "cognitive-emotional" BDI (BDI(c/e)) after exclusion of somatic items. A total of 126 cardiologic inpatients were assessed. Receiver operating characteristic curves (ROC) were calculated for total BDI (BDI(t)) and BDI(c/e). Screening performance of cut-off scores was evaluated using the Youden Index (Y). With the application of the conventional BDI cut-off score, ROC analysis revealed a moderate overall screening performance with Y=52.6 and an area under the curve (AUC) of 0.83. In contrast, Y improved to 57.5 at a cut-off score of >9, but screening performance was still not optimal. BDI(c/e) showed also a moderate screening performance (AUC=.82); Y was maximized at a cut-off score of >8 (Y=0.53.5). Again, no cut-off score provided optimal screening performance. The BDI cannot be recommended as a formal screening instrument in cardiac inpatients since no cut-off score for either BDI(t) or BDI(c/e) combined both sufficiently high sensitivity and specificity. However, the shorter BDI(c/e) could be used as alternative to BDI(t) which may be confounded in physically ill patients. Generally, researchers should consider using alternative screening instruments (e.g., the Hospital Anxiety and Depression Scale) instead.
A cost-effectiveness analysis of screening for silent atrial fibrillation after ischaemic stroke.
Levin, Lars-Åke; Husberg, Magnus; Sobocinski, Piotr Doliwa; Kull, Viveka Frykman; Friberg, Leif; Rosenqvist, Mårten; Davidson, Thomas
2015-02-01
The purpose of this study was to estimate the cost-effectiveness of two screening methods for detection of silent AF, intermittent electrocardiogram (ECG) recordings using a handheld recording device, at regular time intervals for 30 days, and short-term 24 h continuous Holter ECG, in comparison with a no-screening alternative in 75-year-old patients with a recent ischaemic stroke. The long-term (20-year) costs and effects of all alternatives were estimated with a decision analytic model combining the result of a clinical study and epidemiological data from Sweden. The structure of a cost-effectiveness analysis was used in this study. The short-term decision tree model analysed the screening procedure until the onset of anticoagulant treatment. The second part of the decision model followed a Markov design, simulating the patients' health states for 20 years. Continuous 24 h ECG recording was inferior to intermittent ECG in terms of cost-effectiveness, due to both lower sensitivity and higher costs. The base-case analysis compared intermittent ECG screening with no screening of patients with recent stroke. The implementation of the screening programme on 1000 patients resulted over a 20-year period in 11 avoided strokes and the gain of 29 life-years, or 23 quality-adjusted life years, and cost savings of €55 400. Screening of silent AF by intermittent ECG recordings in patients with a recent ischaemic stroke is a cost-effective use of health care resources saving costs and lives and improving the quality of life. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
The focus of this meeting is the SAP's review and comment on the Agency's proposed high-throughput computational model of androgen receptor pathway activity as an alternative to the current Tier 1 androgen receptor assay (OCSPP 890.1150: Androgen Receptor Binding Rat Prostate Cyt...
Osbourn, Gordon C.
1996-01-01
The shadow contrast sensitivity of the human vision system is simulated by configuring information obtained from an image sensor so that the information may be evaluated with multiple pixel widths in order to produce a machine vision system able to distinguish between shadow edges and abrupt object edges. A second difference of the image intensity for each line of the image is developed and this second difference is used to screen out high frequency noise contributions from the final edge detection signals. These edge detection signals are constructed from first differences of the image intensity where the screening conditions are satisfied. The positional coincidence of oppositely signed maxima in the first difference signal taken from the right and the second difference signal taken from the left is used to detect the presence of an object edge. Alternatively, the effective number of responding operators (ENRO) may be utilized to determine the presence of object edges.
Repurposing High-Throughput Image Assays Enables Biological Activity Prediction for Drug Discovery.
Simm, Jaak; Klambauer, Günter; Arany, Adam; Steijaert, Marvin; Wegner, Jörg Kurt; Gustin, Emmanuel; Chupakhin, Vladimir; Chong, Yolanda T; Vialard, Jorge; Buijnsters, Peter; Velter, Ingrid; Vapirev, Alexander; Singh, Shantanu; Carpenter, Anne E; Wuyts, Roel; Hochreiter, Sepp; Moreau, Yves; Ceulemans, Hugo
2018-05-17
In both academia and the pharmaceutical industry, large-scale assays for drug discovery are expensive and often impractical, particularly for the increasingly important physiologically relevant model systems that require primary cells, organoids, whole organisms, or expensive or rare reagents. We hypothesized that data from a single high-throughput imaging assay can be repurposed to predict the biological activity of compounds in other assays, even those targeting alternate pathways or biological processes. Indeed, quantitative information extracted from a three-channel microscopy-based screen for glucocorticoid receptor translocation was able to predict assay-specific biological activity in two ongoing drug discovery projects. In these projects, repurposing increased hit rates by 50- to 250-fold over that of the initial project assays while increasing the chemical structure diversity of the hits. Our results suggest that data from high-content screens are a rich source of information that can be used to predict and replace customized biological assays. Copyright © 2018 Elsevier Ltd. All rights reserved.
Gozalbes, Rafael; Carbajo, Rodrigo J; Pineda-Lucena, Antonio
2010-01-01
In the last decade, fragment-based drug discovery (FBDD) has evolved from a novel approach in the search of new hits to a valuable alternative to the high-throughput screening (HTS) campaigns of many pharmaceutical companies. The increasing relevance of FBDD in the drug discovery universe has been concomitant with an implementation of the biophysical techniques used for the detection of weak inhibitors, e.g. NMR, X-ray crystallography or surface plasmon resonance (SPR). At the same time, computational approaches have also been progressively incorporated into the FBDD process and nowadays several computational tools are available. These stretch from the filtering of huge chemical databases in order to build fragment-focused libraries comprising compounds with adequate physicochemical properties, to more evolved models based on different in silico methods such as docking, pharmacophore modelling, QSAR and virtual screening. In this paper we will review the parallel evolution and complementarities of biophysical techniques and computational methods, providing some representative examples of drug discovery success stories by using FBDD.
Schwaighofer, Andreas; Kuligowski, Julia; Quintás, Guillermo; Mayer, Helmut K; Lendl, Bernhard
2018-06-30
Analysis of proteins in bovine milk is usually tackled by time-consuming analytical approaches involving wet-chemical, multi-step sample clean-up procedures. The use of external cavity-quantum cascade laser (EC-QCL) based IR spectroscopy was evaluated as an alternative screening tool for direct and simultaneous quantification of individual proteins (i.e. casein and β-lactoglobulin) and total protein content in commercial bovine milk samples. Mid-IR spectra of protein standard mixtures were used for building partial least squares (PLS) regression models. A sample set comprising different milk types (pasteurized; differently processed extended shelf life, ESL; ultra-high temperature, UHT) was analysed and results were compared to reference methods. Concentration values of the QCL-IR spectroscopy approach obtained within several minutes are in good agreement with reference methods involving multiple sample preparation steps. The potential application as a fast screening method for estimating the heat load applied to liquid milk is demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hutton, John S
2013-01-01
The issue of electronic media use by young children is increasingly important in pediatrics, a major risk factor for numerous chronic conditions. Despite guidelines in place since 1999, screen time is on the rise, aided by new formats removing practically all barriers of use. Key drivers are technological allure, confusion about developmental readiness, and perception of educational value, fueled by potent marketing. This article describes the development of Baby Unplugged, a series of children's board books celebrating "old-school," screen-free childhood. Written by a pediatrician who also owns a children's bookstore, the books were inspired and informed by advocacy projects in the areas of media use and early literacy as a pediatric resident. They reinforce AAP Electronic Media Guidelines, notably discouraging screen-based media under 2 years old, largely by encouraging healthy, fun alternatives. Examples include Pets, Book, and Yard. Multi-sensorial exploration and parent-child engagement are emphasized in a non-prescriptive way, featuring gender and ethnic diversity and activities that are accessible and inexpensive. The author describes challenges faced by pediatricians providing anticipatory guidance for media use, given limited time and resources and the perception that we are out of touch. This is heightened by oft-deceptive marketing of screen-based products more likely to be perceived as "cool." Reach Out and Read is cited as an example of a successful, "cool" intervention, though limited to select populations. Baby Unplugged takes advocacy to the marketplace, where the screen time battle is being lost.
Yarnoff, Benjamin O; Hoerger, Thomas J; Simpson, Siobhan K; Leib, Alyssa; Burrows, Nilka R; Shrestha, Sundar S; Pavkov, Meda E
2017-03-13
Better treatment during early stages of chronic kidney disease (CKD) may slow progression to end-stage renal disease and decrease associated complications and medical costs. Achieving early treatment of CKD is challenging, however, because a large fraction of persons with CKD are unaware of having this disease. Screening for CKD is one important method for increasing awareness. We examined the cost-effectiveness of identifying persons for early-stage CKD screening (i.e., screening for moderate albuminuria) using published CKD risk scores. We used the CKD Health Policy Model, a micro-simulation model, to simulate the cost-effectiveness of using CKD two published risk scores by Bang et al. and Kshirsagar et al. to identify persons in the US for CKD screening with testing for albuminuria. Alternative risk score thresholds were tested (0.20, 0.15, 0.10, 0.05, and 0.02) above which persons were assigned to receive screening at alternative intervals (1-, 2-, and 5-year) for follow-up screening if the first screening was negative. We examined incremental cost-effectiveness ratios (ICERs), incremental lifetime costs divided by incremental lifetime QALYs, relative to the next higher screening threshold to assess cost-effectiveness. Cost-effective scenarios were determined as those with ICERs less than $50,000 per QALY. Among the cost-effective scenarios, the optimal scenario was determined as the one that resulted in the highest lifetime QALYs. ICERs ranged from $8,823 per QALY to $124,626 per QALY for the Bang et al. risk score and $6,342 per QALY to $405,861 per QALY for the Kshirsagar et al. risk score. The Bang et al. risk score with a threshold of 0.02 and 2-year follow-up screening was found to be optimal because it had an ICER less than $50,000 per QALY and resulted in the highest lifetime QALYs. This study indicates that using these CKD risk scores may allow clinicians to cost-effectively identify a broader population for CKD screening with testing for albuminuria and potentially detect people with CKD at earlier stages of the disease than current approaches of screening only persons with diabetes or hypertension.
Looking at genes in the workplace.
Holden, C
1982-07-23
The Office of Technology Assessment recently testified at a congressional hearing that many corporations are considering genetic screening of employees. Biochemical genetic screening of "susceptible" workers is aimed at identifying individuals unsuitable for specific jobs, and cytogenic monitoring involves the testing of groups of workers for chromosome aberrations that might occur as a result of exposure to chemicals. The apparent surge of interest in such testing requires that several legal, ethical, and policy issues be addressed, including the potential for discrimination, the misuse of screening as an alternative to cleaning up the workplace, the predictive capability of the tests, and the necessity for the development of guidelines for screening programs.
Alternative Fuels Data Center: Video Download Help
a Windows Media Video (WMV) link and select "Save Target As..." from the shortcut menu. To player on the screen. You can also expand the video to play in full-screen mode using Windows Media played in Windows Media Player. Download Windows Media Player. To watch videos on a Mac, double-click the
L.R. Grosenbaugh
1967-01-01
Describes an expansible computerized system that provides data needed in regression or covariance analysis of as many as 50 variables, 8 of which may be dependent. Alternatively, it can screen variously generated combinations of independent variables to find the regression with the smallest mean-squared-residual, which will be fitted if desired. The user can easily...
1997-09-30
Screen, abandoning changes. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official Screens The Ordering Official Screens are provided for...currendy selected Ordering Official will appear on the Ordering Official Information Screen. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official
A choice-based screening method for compulsive drug users in rats.
Lenoir, Magalie; Augier, Eric; Vouillac, Caroline; Ahmed, Serge H
2013-07-01
We describe a protocol for screening compulsive drug users among cocaine self-administering rats, the most frequently used animal model in addiction research. Rats are first trained on several alternating days to self-administer either cocaine (i.v.) or saccharin-sweetened water (by mouth)--a potent, albeit nonessential, nondrug reward. Then rats are allowed to choose between the two rewards over several days until the preference stabilizes. Most rats choose to stop using cocaine and pursue the alternative reward. Only a minority of Wistar strain rats (generally 15%) persist in taking the drug, regardless of the severity of past cocaine use and even when made hungry and offered the possibility to relieve their physiological need. Persistence of cocaine use in the face of a high-stakes choice is a core defining feature of compulsion. This choice-based screening method for compulsive drug users is easy to implement, has several important applications, and compares well with other methods in the field. 2013 by John Wiley & Sons, Inc.
Racz, Peter I; Wildwater, Marjolein; Rooseboom, Martijn; Kerkhof, Engelien; Pieters, Raymond; Yebra-Pimentel, Elena Santidrian; Dirks, Ron P; Spaink, Herman P; Smulders, Chantal; Whale, Graham F
2017-10-01
To enable selection of novel chemicals for new processes, there is a recognized need for alternative toxicity screening assays to assess potential risks to man and the environment. For human health hazard assessment these screening assays need to be translational to humans, have high throughput capability, and from an animal welfare perspective be harmonized with the principles of the 3Rs (Reduction, Refinement, Replacement). In the area of toxicology a number of cell culture systems are available but while these have some predictive value, they are not ideally suited for the prediction of developmental and reproductive toxicology (DART). This is because they often lack biotransformation capacity, multicellular or multi- organ complexity, for example, the hypothalamus pituitary gonad (HPG) axis and the complete life cycle of whole organisms. To try to overcome some of these limitations in this study, we have used Caenorhabditis elegans (nematode) and Danio rerio embryos (zebrafish) as alternative assays for DART hazard assessment of some candidate chemicals being considered for a new commercial application. Nematodes exposed to Piperazine and one of the analogs tested showed a slight delay in development compared to untreated animals but only at high concentrations and with Piperazine as the most sensitive compound. Total brood size of the nematodes was also reduced primarily by Piperazine and one of the analogs. In zebrafish Piperazine and analogs showed developmental delays. Malformations and mortality in individual fish were also scored. Significant malformations were most sensitively identified with Piperazine, significant mortality was only observed in Piperazine and only at the higest dose. Thus, Piperazine seemed the most toxic compound for both nematodes and zebrafish. The results of the nematode and zebrafish studies were in alignment with data obtained from conventional mammalian toxicity studies indicating that these have potential as developmental toxicity screening systems. The results of these studies also provided reassurance that none of the Piperazines tested are likely to have any significant developmental and/or reproductive toxicity issues to humans when used in their commercial applications. Copyright © 2017. Published by Elsevier Ltd.
Ji, Yu; Tian, Yang; Ahnfelt, Mattias; Sui, Lili
2014-06-27
Multivalent pneumococcal vaccines were used worldwide to protect human beings from pneumococcal diseases. In order to eliminate the toxic organic solutions used in the traditional vaccine purification process, an alternative chromatographic process for Streptococcus pneumoniae serotype 23F capsular polysaccharide (CPS) was proposed in this study. The strategy of Design of Experiments (DoE) was introduced into the process development to solve the complicated design procedure. An initial process analysis was given to review the whole flowchart, identify the critical factors of chromatography through FMEA and chose the flowthrough mode due to the property of the feed. A resin screening study was then followed to select candidate resins. DoE was utilized to generate a resolution IV fractional factorial design to further compare candidates and narrow down the design space. After Capto Adhere was selected, the Box-Behnken DoE was executed to model the process and characterize all effects of factors on the responses. Finally, Monte Carlo simulation was used to optimize the process, test the chosen optimal conditions and define the control limit. The results of three scale-up runs at set points verified the DoE and simulation predictions. The final results were well in accordance with the EU pharmacopeia requirements: Protein/CPS (w/w) 1.08%; DNA/CPS (w/w) 0.61%; the phosphorus content 3.1%; the nitrogen 0.315% and the Methyl-pentose percentage 47.9%. Other tests of final pure CPS also met the pharmacopeia specifications. This alternative chromatographic purification process for pneumococcal vaccine without toxic organic solvents was successfully developed by the DoE approach and proved scalability, robustness and suitability for large scale manufacturing. Copyright © 2014 Elsevier B.V. All rights reserved.
Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari
2016-01-01
Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25–69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway. PMID:27073929
Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari
2016-01-01
Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.
A Disposable Microfluidic Device with a Screen Printed Electrode for Mimicking Phase II Metabolism
Vasiliadou, Rafaela; Nasr Esfahani, Mohammad Mehdi; Brown, Nathan J.; Welham, Kevin J.
2016-01-01
Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler and a cheaper alternative to mimic the human metabolism. This paper describes the development of a disposable microfluidic device with a screen-printed electrode (SPE) for monitoring phase II GSH reactions. The proposed chip has the potential to be used as a primary screening tool, thus complementing the current in vitro methods. PMID:27598162
Predicting Sepsis Risk Using the "Sniffer" Algorithm in the Electronic Medical Record.
Olenick, Evelyn M; Zimbro, Kathie S; DʼLima, Gabrielle M; Ver Schneider, Patricia; Jones, Danielle
The Sepsis "Sniffer" Algorithm (SSA) has merit as a digital sepsis alert but should be considered an adjunct to versus an alternative for the Nurse Screening Tool (NST), given lower specificity and positive predictive value. The SSA reduced the risk of incorrectly categorizing patients at low risk for sepsis, detected sepsis high risk in half the time, and reduced redundant NST screens by 70% and manual screening hours by 64% to 72%. Preserving nurse hours expended on manual sepsis alerts may translate into time directed toward other patient priorities.
Nasir, Muhammad Zafir Mohamad; Pumera, Martin
2016-10-12
Impact electrochemistry provides a useful alternative technique for the detection of silver nanoparticles in solutions. The combined use of impact electrochemistry on screen-printed electrodes (SPEs) for the successful detection of silver nanoparticles provides an avenue for future on-site, point-of-care detection devices to be made for environmental, medicinal and biological uses. Here we discuss the use of screen-printed electrodes for the detection of well-defined monodispersed silver nanoparticles of sizes 10, 20, 40, 80, and 107 nm.
Friedman, Allison L; Bloodgood, Bonny
2013-01-01
Annual chlamydia screening is recommended for sexually active women aged 25 years and younger, though less than half of eligible women are screened each year. If acceptable to young women, nontraditional testing venues and new communication technologies could promote efficiencies in sexually transmitted disease (STD) screening and facilitate screening by overcoming barriers at systems and patient levels. This study sought to explore young women's technology use, preferences for STD-testing venues, attitudes toward nontraditional venues, and acceptability of test results delivery options. A total of 80 ethnographic one-on-one telephone interviews were conducted with African American, Caucasian, and Latina women, aged 15 to 25 years, in 10 metropolitan areas of the United States. Interviews were recorded, transcribed, and analyzed using NVivo2. Alternative STD-testing venues and results delivery channels are valued by young women for their convenience and accessibility, but they must also offer privacy, confidentiality, and emotional/informational support to be acceptable. Assuring provider (or self) competence and valid/accurate test results is also important. Although new technologies have been embraced by young women for personal and social uses, they may not be as readily embraced for the provision of STD-related services. Additional social marketing efforts may be needed to promote acceptance of nontraditional STD-testing settings and results delivery methods.
Martin, Todd M
2017-05-01
The goal of alternatives assessment (AA) is to facilitate a comparison of alternatives to a chemical of concern, resulting in the identification of safer alternatives. A two stage methodology for comparing chemical alternatives was developed. In the first stage, alternatives are compared using a variety of human health effects, ecotoxicity, and physicochemical properties. Hazard profiles are completed using a variety of online sources and quantitative structure activity relationship models. In the second stage, alternatives are evaluated utilizing an exposure/risk assessment over the entire life cycle. Exposure values are calculated using screening-level near-field and far-field exposure models. The second stage allows one to more accurately compare potential exposure to each alternative and consider additional factors that may not be obvious from separate binned persistence, bioaccumulation, and toxicity scores. The methodology was utilized to compare phosphate-based alternatives for decabromodiphenyl ether (decaBDE) in electronics applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurogi, Yutaro; Matsuo, Yota; Mihara, Yuki
2014-03-28
Highlights: • We identified tubercidin as a compound inducing aberrant formation of the speckles. • Tubercidin causes delocalization of poly (A){sup +}RNAs from nuclear speckles. • Tubercidin induces dispersion of splicing factors from nuclear speckles. • Tubercidin affects alternative pre-mRNA splicing. • Nuclear speckles play a role in regulation of alternative pre-mRNA splicing. - Abstract: Nuclear speckles are subnuclear structures enriched with RNA processing factors and poly (A){sup +} RNAs comprising mRNAs and poly (A){sup +} non-coding RNAs (ncRNAs). Nuclear speckles are thought to be involved in post-transcriptional regulation of gene expression, such as pre-mRNA splicing. By screening 3585 culturemore » extracts of actinomycetes with in situ hybridization using an oligo dT probe, we identified tubercidin, an analogue of adenosine, as an inhibitor of speckle formation, which induces the delocalization of poly (A){sup +} RNA and dispersion of splicing factor SRSF1/SF2 from nuclear speckles in HeLa cells. Treatment with tubercidin also decreased steady-state MALAT1 long ncRNA, thought to be involved in the retention of SRSF1/SF2 in nuclear speckles. In addition, we found that tubercidin treatment promoted exon skipping in the alternative splicing of Clk1 pre-mRNA. These results suggest that nuclear speckles play a role in modulating the concentration of splicing factors in the nucleoplasm to regulate alternative pre-mRNA splicing.« less
Smart material screening machines using smart materials and controls
NASA Astrophysics Data System (ADS)
Allaei, Daryoush; Corradi, Gary; Waigand, Al
2002-07-01
The objective of this product is to address the specific need for improvements in the efficiency and effectiveness in physical separation technologies in the screening areas. Currently, the mining industry uses approximately 33 billion kW-hr per year, costing 1.65 billion dollars at 0.05 cents per kW-hr, of electrical energy for physical separations. Even though screening and size separations are not the single most energy intensive process in the mining industry, they are often the major bottleneck in the whole process. Improvements to this area offer tremendous potential in both energy savings and production improvements. Additionally, the vibrating screens used in the mining processing plants are the most costly areas from maintenance and worker health and safety point of views. The goal of this product is to reduce energy use in the screening and total processing areas. This goal is accomplished by developing an innovative screening machine based on smart materials and smart actuators, namely smart screen that uses advanced sensory system to continuously monitor the screening process and make appropriate adjustments to improve production. The theory behind the development of Smart Screen technology is based on two key technologies, namely smart actuators and smart Energy Flow ControlT (EFCT) strategies, developed initially for military applications. Smart Screen technology controls the flow of vibration energy and confines it to the screen rather than shaking much of the mass that makes up the conventional vibratory screening machine. Consequently, Smart Screens eliminates and downsizes many of the structural components associated with conventional vibratory screening machines. As a result, the surface area of the screen increases for a given envelope. This increase in usable screening surface area extends the life of the screens, reduces required maintenance by reducing the frequency of screen change-outs and improves throughput or productivity.
Tufail, Adnan; Rudisill, Caroline; Egan, Catherine; Kapetanakis, Venediktos V; Salas-Vega, Sebastian; Owen, Christopher G; Lee, Aaron; Louw, Vern; Anderson, John; Liew, Gerald; Bolter, Louis; Srinivas, Sowmya; Nittala, Muneeswar; Sadda, SriniVas; Taylor, Paul; Rudnicka, Alicja R
2017-03-01
With the increasing prevalence of diabetes, annual screening for diabetic retinopathy (DR) by expert human grading of retinal images is challenging. Automated DR image assessment systems (ARIAS) may provide clinically effective and cost-effective detection of retinopathy. We aimed to determine whether ARIAS can be safely introduced into DR screening pathways to replace human graders. Observational measurement comparison study of human graders following a national screening program for DR versus ARIAS. Retinal images from 20 258 consecutive patients attending routine annual diabetic eye screening between June 1, 2012, and November 4, 2013. Retinal images were manually graded following a standard national protocol for DR screening and were processed by 3 ARIAS: iGradingM, Retmarker, and EyeArt. Discrepancies between manual grades and ARIAS results were sent to a reading center for arbitration. Screening performance (sensitivity, false-positive rate) and diagnostic accuracy (95% confidence intervals of screening-performance measures) were determined. Economic analysis estimated the cost per appropriate screening outcome. Sensitivity point estimates (95% confidence intervals) of the ARIAS were as follows: EyeArt 94.7% (94.2%-95.2%) for any retinopathy, 93.8% (92.9%-94.6%) for referable retinopathy (human graded as either ungradable, maculopathy, preproliferative, or proliferative), 99.6% (97.0%-99.9%) for proliferative retinopathy; Retmarker 73.0% (72.0 %-74.0%) for any retinopathy, 85.0% (83.6%-86.2%) for referable retinopathy, 97.9% (94.9%-99.1%) for proliferative retinopathy. iGradingM classified all images as either having disease or being ungradable. EyeArt and Retmarker saved costs compared with manual grading both as a replacement for initial human grading and as a filter prior to primary human grading, although the latter approach was less cost-effective. Retmarker and EyeArt systems achieved acceptable sensitivity for referable retinopathy when compared with that of human graders and had sufficient specificity to make them cost-effective alternatives to manual grading alone. ARIAS have the potential to reduce costs in developed-world health care economies and to aid delivery of DR screening in developing or remote health care settings. Copyright © 2016 American Academy of Ophthalmology. All rights reserved.
Grimm, Fabian A; Iwata, Yasuhiro; Sirenko, Oksana; Chappell, Grace A; Wright, Fred A; Reif, David M; Braisted, John; Gerhold, David L; Yeakley, Joanne M; Shepard, Peter; Seligmann, Bruce; Roy, Tim; Boogaard, Peter J; Ketelslegers, Hans B; Rohde, Arlean M; Rusyn, Ivan
2016-08-21
Comparative assessment of potential human health impacts is a critical step in evaluating both chemical alternatives and existing products on the market. Most alternatives assessments are conducted on a chemical-by-chemical basis and it is seldom acknowledged that humans are exposed to complex products, not individual substances. Indeed, substances of U nknown or V ariable composition, C omplex reaction products, and B iological materials (UVCBs) are ubiquitous in commerce yet they present a major challenge for registration and health assessments. Here, we present a comprehensive experimental and computational approach to categorize UVCBs according to global similarities in their bioactivity using a suite of in vitro models. We used petroleum substances, an important group of UVCBs which are grouped for regulatory approval and read-across primarily on physico-chemical properties and the manufacturing process, and only partially based on toxicity data, as a case study. We exposed induced pluripotent stem cell-derived cardiomyocytes and hepatocytes to DMSO-soluble extracts of 21 petroleum substances from five product groups. Concentration-response data from high-content imaging in cardiomyocytes and hepatocytes, as well as targeted high-throughput transcriptomic analysis of the hepatocytes, revealed distinct groups of petroleum substances. Data integration showed that bioactivity profiling affords clustering of petroleum substances in a manner similar to the manufacturing process-based categories. Moreover, we observed a high degree of correlation between bioactivity profiles and physico-chemical properties, as well as improved groupings when chemical and biological data were combined. Altogether, we demonstrate how novel in vitro screening approaches can be effectively utilized in combination with physico-chemical characteristics to group complex substances and enable read-across. This approach allows for rapid and scientifically-informed evaluation of health impacts of both existing substances and their chemical alternatives.
Isolated colorectal cancer screening or integrated cancer prevention? A provocative suggestion!
Stockbrugger, Reinhold
2012-01-01
Colorectal cancer (CRC) screening is still not fully established in the European Union. Recently, the United European Gastroenterology Federation (UEGF) supported CRC screening with the publication of quality guidelines and a written declaration in the European Parliament in favor of European-wide monitored CRC screening and primary prevention of CRC, the latter particularly in young citizens. In this article, the need for population-based CRC screening is once again stressed. In addition, the value of opportunistic CRC screening is pointed out, either as a regional or nation-wide alternative (such as in the USA and Germany) or as a 'forerunner' activity in view of subsequent population-based CRC screening. With regard to other parallel organ-related screening activities in Europe (breast, uterus) and the increasing need for primary prevention of malignant and benign diseases, the question is raised as to whether preventive activities should not be recognized as an integrated and logical part of a 'healthcare chain' offered to all European citizens. Copyright © 2012 S. Karger AG, Basel.
Organizational Factors and the Cancer Screening Process
Zapka, Jane; Edwards, Heather; Taplin, Stephen H.
2010-01-01
Cancer screening is a process of care consisting of several steps and interfaces. This article reviews what is known about the association between organizational factors and cancer screening rates and examines how organizational strategies can address the steps and interfaces of cancer screening in the context of both intraorganizational and interorganizational processes. We reviewed 79 studies assessing the relationship between organizational factors and cancer screening. Screening rates are largely driven by strategies to 1) limit the number of interfaces across organizational boundaries; 2) recruit patients, promote referrals, and facilitate appointment scheduling; and 3) promote continuous patient care. Optimal screening rates can be achieved when health-care organizations tailor strategies to the steps and interfaces in the cancer screening process that are most critical for their organizations, the providers who work within them, and the patients they serve. PMID:20386053
Organizational factors and the cancer screening process.
Anhang Price, Rebecca; Zapka, Jane; Edwards, Heather; Taplin, Stephen H
2010-01-01
Cancer screening is a process of care consisting of several steps and interfaces. This article reviews what is known about the association between organizational factors and cancer screening rates and examines how organizational strategies can address the steps and interfaces of cancer screening in the context of both intraorganizational and interorganizational processes. We reviewed 79 studies assessing the relationship between organizational factors and cancer screening. Screening rates are largely driven by strategies to 1) limit the number of interfaces across organizational boundaries; 2) recruit patients, promote referrals, and facilitate appointment scheduling; and 3) promote continuous patient care. Optimal screening rates can be achieved when health-care organizations tailor strategies to the steps and interfaces in the cancer screening process that are most critical for their organizations, the providers who work within them, and the patients they serve.
HRM and SNaPshot as alternative forensic SNP genotyping methods.
Mehta, Bhavik; Daniel, Runa; McNevin, Dennis
2017-09-01
Single nucleotide polymorphisms (SNPs) have been widely used in forensics for prediction of identity, biogeographical ancestry (BGA) and externally visible characteristics (EVCs). Single base extension (SBE) assays, most notably SNaPshot® (Thermo Fisher Scientific), are commonly used for forensic SNP genotyping as they can be employed on standard instrumentation in forensic laboratories (e.g. capillary electrophoresis). High resolution melt (HRM) analysis is an alternative method and is a simple, fast, single tube assay for low throughput SNP typing. This study compares HRM and SNaPshot®. HRM produced reproducible and concordant genotypes at 500 pg, however, difficulties were encountered when genotyping SNPs with high GC content in flanking regions and differentiating variants of symmetrical SNPs. SNaPshot® was reproducible at 100 pg and is less dependent on SNP choice. HRM has a shorter processing time in comparison to SNaPshot®, avoids post PCR contamination risk and has potential as a screening tool for many forensic applications.
A risk/cost analysis of alternative screening intervals for occupational tuberculosis infection.
Nicas, M
1998-02-01
The Centers for Disease Control and Prevention (CDC) recommends that new health care employees receive a baseline skin test for Mycobacterium tuberculosis (M. tb) infection and that testing be repeated periodically. However, CDC does not explain the quantitative basis for its suggested screening intervals. This article examines the efficacy of alternative screening intervals for workers subject to different annual rates of M. tb infection and estimates the costs. An equation is developed for the cumulative risk of tuberculosis (TB) at 12 years given a specified annual rate of infection (ARI), screening interval, and a combined proportion (p) of successful skin testing and antibiotic prophylaxis. Equations for total cost of screening and cost per disease case prevented are provided. Results assume: (a) costs of $10 per skin test and $10,000 per TB disease case; (b) p = 0.88; and (c) and acceptable cumulative TB risk of 1 per 1000. For ARIs that might be deemed low (0.2% to 0.5%) and medium (1%), CDC screening intervals of 12 months and 6-12 months, respectively, minimize the cost per disease case prevented but permit residual disease risks greater than 1 per 1000. Recommended screening intervals are (i) 6 months for low-risk employee groups and (ii) 3 months for medium- and high-risk (e.g., ARIs of > or = 5%) groups. Interval (i) limits risk to 1 per 1000 and is approximately 50% shorter than the CDC interval for a low-risk group. Interval (ii), which is 67% shorter than the CDC interval for medium-risk groups but equal to that recommended for high-risk groups, permits a risk above 1 per 1000, but is likely the shortest feasible interval.
Cathepsin D immobilized capillary reactors for on-flow screening assays.
Cornelio, Vivian Estevam; de Moraes, Marcela Cristina; Domingues, Vanessa de Cassia; Fernandes, João Batista; da Silva, Maria Fátima das Gracas Fernandes; Cass, Quezia Bezerra; Vieira, Paulo Cezar
2018-03-20
The treatment of diseases using enzymes as targets has called for the development of new and reliable methods for screening. The protease cathepsin D is one such target involved in several diseases such as tumors, degenerative processes, and vital processes of parasites causing schistosomiasis. Herein, we describe the preparation of a fused silica capillary, cathepsin D (CatD)-immobilized enzyme reactor (IMER) using in a multidimensional High Performance Liquid Chromatography-based method (2D-HPLC) and zonal affinity chromatography as an alternative in the search for new ligands. The activity and kinetic parameters of CatD-IMER were evaluated by monitoring the product MOCAc-Gly-Lys-Pro-Ile-Leu-Phe (P-MOCAc) (K M = 81.9 ± 7.49 μmol/L) generated by cleavage of the fluorogenic substrate MOCAc-Gly-Lys-Pro-Ile-Leu-Phe-Phe-Arg-Leu-Lys(DNP)-d-Arg-NH2 (S-MOCAc). Stability studies have indicated that CatD-IMER retained 20% of activity after 5 months, a relevant result, because proteases are susceptible to autoproteolysis in solution assays with free enzyme. In the search for inhibitors, 12 crude natural product extracts were analyzed using CatD-IMER as the target, resulting in the isolation of different classes of natural products. In addition, 26 compounds obtained from different species of plants were also screened, demonstrating the efficiency and reproducibility of the herein reported assay even in the case of complex matrices such as plant crude extracts. Copyright © 2018 Elsevier B.V. All rights reserved.
Ding, Zhiyong; German, Peter; Bai, Shanshan; Feng, Zhehui; Gao, Meng; Si, Wendy; Sobieski, Mary M.; Stephan, Clifford C.; Mills, Gordon B.; Jonasch, Eric
2014-01-01
Background von Hippel Lindau (VHL) disease is an autosomal dominant inherited disorder that results in multiple organ systems being affected. Treatment is mainly surgical, however, effective systemic therapies are needed. We developed and tested a cell-based screening tool to identify compounds that stabilize or upregulate full-length, point mutated VHL. Methods The 786-0 cell line was infected with full-length W117A mutated VHL linked to a C-terminal Venus fluorescent protein. This VHL-W117A-Venus line was used to screen the Prestwick drug library and was tested against the known proteasome inhibitors MG132 and bortezomib. Western blot validation and evaluation of downstream functional readouts, including HIF and GLUT1 levels, were performed. Results Bortezomib, MG132, and the Prestwick compounds 8-azaguanine, thiostrepton and thioguanosine were found to reliably upregulate VHL-W117A-Venus in 786-0 cells. 8-azaguanine was found to downregulate HIF2α levels, and was augmented by the presence of VHL W117A. VHL p30 band intensities varied as a function of compound used, suggesting alternate post-translational processing. In addition, nuclear-cytoplasmic localization of pVHL varied amongst the different compounds. Conclusion 786-0 cells containing VHL-W117A-Venus can be successfully used to identify compounds that upregulate VHL levels, and that have a differential effect on pVHL intracellular localization and posttranslational processing. Further screening efforts will broaden the number of pharmacophores available to develop therapeutic agents that will upregulate and refunctionalize mutated VHL. PMID:22357874
Kim, Jane J.; Schapira, Marilyn M.; Tosteson, Anna N. A.; Zauber, Ann G.; Geiger, Ann M.; Kamineni, Aruna; Weaver, Donald L.; Tiro, Jasmin A.
2015-01-01
General frameworks of the cancer screening process are available, but none directly compare the process in detail across different organ sites. This limits the ability of medical and public health professionals to develop and evaluate coordinated screening programs that apply resources and population management strategies available for one cancer site to other sites. We present a trans-organ conceptual model that incorporates a single screening episode for breast, cervical, and colorectal cancers into a unified framework based on clinical guidelines and protocols; the model concepts could be expanded to other organ sites. The model covers four types of care in the screening process: risk assessment, detection, diagnosis, and treatment. Interfaces between different provider teams (eg, primary care and specialty care), including communication and transfer of responsibility, may occur when transitioning between types of care. Our model highlights across each organ site similarities and differences in steps, interfaces, and transitions in the screening process and documents the conclusion of a screening episode. This model was developed within the National Cancer Institute–funded consortium Population-based Research Optimizing Screening through Personalized Regimens (PROSPR). PROSPR aims to optimize the screening process for breast, cervical, and colorectal cancer and includes seven research centers and a statistical coordinating center. Given current health care reform initiatives in the United States, this conceptual model can facilitate the development of comprehensive quality metrics for cancer screening and promote trans-organ comparative cancer screening research. PROSPR findings will support the design of interventions that improve screening outcomes across multiple cancer sites. PMID:25957378
Manner, Suvi; Fallarero, Adyary
2018-05-03
Owing to the failure of conventional antibiotics in biofilm control, alternative approaches are urgently needed. Inhibition of quorum sensing (QS) represents an attractive target since it is involved in several processes essential for biofilm formation. In this study, a compound library of natural product derivatives ( n = 3040) was screened for anti-quorum sensing activity using Chromobacterium violaceum as reporter bacteria. Screening assays, based on QS-mediated violacein production and viability, were performed in parallel to identify non-bactericidal QS inhibitors (QSIs). Nine highly active QSIs were identified, while 328 compounds were classified as moderately actives and 2062 compounds as inactives. Re-testing of the highly actives at a lower concentration against C. violaceum , complemented by a literature search, led to the identification of two flavonoid derivatives as the most potent QSIs, and their impact on biofilm maturation in Escherichia coli and Pseudomonas aeruginosa was further investigated. Finally, effects of these leads on swimming and swarming motility of P. aeruginosa were quantified. The identified flavonoids affected all the studied QS-related functions at micromolar concentrations. These compounds can serve as starting points for further optimization and development of more potent QSIs as adjunctive agents used with antibiotics in the treatment of biofilms.
Kaku, Hiroki; Inoue, Kanako; Muranaka, Yoshinori; Park, Pyoyun; Ikeda, Kenichi
2015-10-01
Uranyl salts are toxic and radioactive; therefore, several studies have been conducted to screen for substitutes of electron stains. In this regard, the contrast evaluation process is time consuming and the results obtained are inconsistent. In this study, we developed a novel contrast evaluation method using affinity beads and a backscattered electron image (BSEI), obtained using scanning electron microscopy. The contrast ratios of BSEI in each electron stain treatment were correlated with those of transmission electron microscopic images. The affinity beads bound to cell components independently. Protein and DNA samples were enhanced by image contrast treated with electron stains; however, this was not observed for sugars. Protein-conjugated beads showed an additive effect of image contrast when double-stained with lead. However, additive effect of double staining was not observed in DNA-conjugated beads. The varying chemical properties of oligopeptides showed differences in image contrast when treated with each electron stain. This BSEI-based evaluation method not only enables screening for alternate electron stains, but also helps analyze the underlying mechanisms of electron staining of cellular structures. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Predictive Models for Carcinogenicity and Mutagenicity ...
Mutagenicity and carcinogenicity are endpoints of major environmental and regulatory concern. These endpoints are also important targets for development of alternative methods for screening and prediction due to the large number of chemicals of potential concern and the tremendous cost (in time, money, animals) of rodent carcinogenicity bioassays. Both mutagenicity and carcinogenicity involve complex, cellular processes that are only partially understood. Advances in technologies and generation of new data will permit a much deeper understanding. In silico methods for predicting mutagenicity and rodent carcinogenicity based on chemical structural features, along with current mutagenicity and carcinogenicity data sets, have performed well for local prediction (i.e., within specific chemical classes), but are less successful for global prediction (i.e., for a broad range of chemicals). The predictivity of in silico methods can be improved by improving the quality of the data base and endpoints used for modelling. In particular, in vitro assays for clastogenicity need to be improved to reduce false positives (relative to rodent carcinogenicity) and to detect compounds that do not interact directly with DNA or have epigenetic activities. New assays emerging to complement or replace some of the standard assays include VitotoxTM, GreenScreenGC, and RadarScreen. The needs of industry and regulators to assess thousands of compounds necessitate the development of high-t
The Telephone Interview for Cognitive Status: Creating a crosswalk with the Mini-Mental State Exam
Fong, Tamara G.; Fearing, Michael A.; Jones, Richard N.; Shi, Peilin; Marcantonio, Edward R.; Rudolph, James L.; Yang, Frances M.; Kiely, Dan K.; Inouye, Sharon K.
2009-01-01
Background Brief cognitive screening measures are valuable tools for both research and clinical applications. The most widely used instrument, the Mini-Mental State Examination (MMSE) is limited in that it must be administered face-to-face, cannot be used in participants with visual or motor impairments, and is protected by copyright. Alternative screening instruments, such as the Telephone Interview for Cognitive Status (TICS) have been developed and may provide a valid alternative with comparable cut point scores to rate global cognitive function. Methods MMSE, TICS-30, and TICS-40 scores from 746 community dwelling elders who participated in the Aging, Demographics, and Memory Study (ADAMS) were analyzed with equipercentile equating, a statistical process of determining comparable scores based on percentile equivalents on different forms of an examination. Results Scores from the MMSE and the TICS-30 and TICS-40 corresponded well and clinically relevant cut point scores were determined; for example, an MMSE score of 23 is equivalent to 17 and 20 on the TICS-30 and TICS-40, respectively. Conclusions These findings provide scores that can be used to link TICS and MMSE scores directly. Clinically relevant and important MMSE cut points and the respective ADAMS TICS-30 and TICS-40 cut point scores have been included to identify the degree of cognitive impairment among respondents with any type of cognitive disorder. These results will help with the widespread application of the TICS in both research and clinical practice. PMID:19647495
NASA Astrophysics Data System (ADS)
Mai, Juliane; Cuntz, Matthias; Shafii, Mahyar; Zink, Matthias; Schäfer, David; Thober, Stephan; Samaniego, Luis; Tolson, Bryan
2016-04-01
Hydrologic models are traditionally calibrated against observed streamflow. Recent studies have shown however, that only a few global model parameters are constrained using this kind of integral signal. They can be identified using prior screening techniques. Since different objectives might constrain different parameters, it is advisable to use multiple information to calibrate those models. One common approach is to combine these multiple objectives (MO) into one single objective (SO) function and allow the use of a SO optimization algorithm. Another strategy is to consider the different objectives separately and apply a MO Pareto optimization algorithm. In this study, two major research questions will be addressed: 1) How do multi-objective calibrations compare with corresponding single-objective calibrations? 2) How much do calibration results deteriorate when the number of calibrated parameters is reduced by a prior screening technique? The hydrologic model employed in this study is a distributed hydrologic model (mHM) with 52 model parameters, i.e. transfer coefficients. The model uses grid cells as a primary hydrologic unit, and accounts for processes like snow accumulation and melting, soil moisture dynamics, infiltration, surface runoff, evapotranspiration, subsurface storage and discharge generation. The model is applied in three distinct catchments over Europe. The SO calibrations are performed using the Dynamically Dimensioned Search (DDS) algorithm with a fixed budget while the MO calibrations are achieved using the Pareto Dynamically Dimensioned Search (PA-DDS) algorithm allowing for the same budget. The two objectives used here are the Nash Sutcliffe Efficiency (NSE) of the simulated streamflow and the NSE of the logarithmic transformation. It is shown that the SO DDS results are located close to the edges of the Pareto fronts of the PA-DDS. The MO calibrations are hence preferable due to their supply of multiple equivalent solutions from which the user can choose at the end due to the specific needs. The sequential single-objective parameter screening was employed prior to the calibrations reducing the number of parameters by at least 50% in the different catchments and for the different single objectives. The single-objective calibrations led to a faster convergence of the objectives and are hence beneficial when using a DDS on single-objectives. The above mentioned parameter screening technique is generalized for multi-objectives and applied before calibration using the PA-DDS algorithm. Two different alternatives of this MO-screening are tested. The comparison of the calibration results using all parameters and using only screened parameters shows for both alternatives that the PA-DDS algorithm does not profit in terms of trade-off size and function evaluations required to achieve converged pareto fronts. This is because the PA-DDS algorithm automatically reduces search space with progress of the calibration run. This automatic reduction should be different for other search algorithms. It is therefore hypothesized that prior screening can but must not be beneficial for parameter estimation dependent on the chosen optimization algorithm.
Aviation Security: Vulnerabilities in, and Alternatives for, Preboard Screening Security Operations
2001-09-25
establishing the certification program. This regulation is particularly significant because it is to include requirements mandated by the Airport Security Improvement...Assessment of Airport Security Screener Performance and Retention, Sept. 15, 2000. Page 8 GAO-01-1171T Criteria for Assessing Shifting responsibility for...airline and airport security officials to assess each option for reassigning screening responsibility against the key criteria- Specifically, we asked
Comparison of the PSC-17 and Alternative Mental Health Screens in an At-Risk Primary Care Sample
ERIC Educational Resources Information Center
Gardner, William; Lucas, Amanda; Kolko, David J.; Campo, John V.
2007-01-01
Objective: To validate the 17-item version of the Pediatric Symptom Checklist (PSC-17) as a screen for common pediatric mental disorders in primary care. Method: Patients were 269 children and adolescents (8-15 years old) whose parents completed the PSC-17 in primary care waiting rooms. Children were later assessed using the Schedule for Affective…
Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R
2000-09-01
To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.
Managing seafood processing wastewater on the Oregon coast: A time of transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, M.D.; Miner, J.R.
1997-12-01
Seafood processors along the Oregon coast practice a wastewater management plan that is unique within the state. Most of these operations discharge wastewater under a General Permit issued by the Oregon Department of Environmental Quality (DEQ) that requires only that they screen the wastewater to remove particles that will not pass through a 40 mesh screen. The General Permit was issued in February of 1992 and was scheduled to expire at the end of December, 1996. It has been extended until a replacement is adopted. Alternatives are currently under consideration by the DEQ. A second issue is the increasing competitionmore » for water within the coastal communities that are experiencing a growing tourist industry and a static water supply. Tourism and seafood processing both have their peak water demands during the summer months when fresh water supplies are most limited. Disposal of solid wastes has been simplified for many of the processors along the Lower Columbia River by a Fisheries Enhancement Program which allows processors to grind the solid waste then to discharge it into the stream under appropriate tidal conditions. There is no data which indicates water quality damage from this practice nor is there clear evidence of enhanced fishery productivity.« less
NASA Astrophysics Data System (ADS)
Hikmah, M.; Setyaningsih, R.; Pangastuti, A.
2018-03-01
Plastic is experiencing buildup in the environment. Biodegradation process can be used as an alternative for LDPE plastic degradation because the process is environmentally friendly. Some fungi of the genus Trichoderma are known to have a role in plastic biodegradation. This study aims to find out how the potential of that lignolytic Trichoderma spp. isolates in LDPE biodegradation. Five isolates were screened by growing on MSMB (mineral salt medium broth) emulsified LDPE powder, with 35 days incubation at 30°C and shaking at 80 rpm. TL1, TL4, and TL5 are the three most potential isolates, indicated by the growth marked by increasing colony size on screening media. They were then tested for biodegradability by growing the isolates in MSMA (mineral salt medium agar) which then inoculated by 4 sheets of sterile LDPE 1x3 cm2 above the colony surface, incubated for 5, 15, 25 and 35 days. The degredability assessment is done by measuring the weight loss of LDPE sheets after biodegradation treatment. The obtained degradability percentage of TL1, TL4, and TL5 are 4.87%, 7.12%, and 7,51% respectively. The visual micrograph of LDPE film by SEM showed the appearance of damage and unevenness on the surface of the post-degradation film.
Impact of single particle oscillations on screening of a test charge
NASA Astrophysics Data System (ADS)
Ramazanov, Tlekkabul S.; Moldabekov, Zhandos A.; Gabdullin, Maratbek T.
2018-06-01
Screening of a test charge by electrons oscillating in an external alternating electrical (laser) field is analyzed. It is shown that single particle oscillations lead to the creation of an oscillatory pattern of the test charge's potential at large distances. Analysis has been done by considering and neglecting the contribution of ions on the screening. Impact of the quantum diffraction (non-locality) and of the collisional damping on the test charge's potential is considered. It is shown that electrons are unable to provide screening of the test charge if the frequency of the induced single particle oscillations larger than the electron-plasma frequency. In the opposite case of low frequencies, the potential of the test charge changes its sign if the screening by ions is neglected.
An NCI database that contains the latest information about cancer treatment, screening, prevention, genetics, supportive care, and complementary and alternative medicine, plus drug information and a dictionary of cancer terms.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requests personal property that is undergoing donation screening or in the sales process? 102-36.270... agency requests personal property that is undergoing donation screening or in the sales process? Prior to... property undergoing donation screening or in the sales process. Federal transfers may be authorized prior...
Code of Federal Regulations, 2012 CFR
2012-01-01
... requests personal property that is undergoing donation screening or in the sales process? 102-36.270... agency requests personal property that is undergoing donation screening or in the sales process? Prior to... property undergoing donation screening or in the sales process. Federal transfers may be authorized prior...
Code of Federal Regulations, 2014 CFR
2014-01-01
... requests personal property that is undergoing donation screening or in the sales process? 102-36.270... agency requests personal property that is undergoing donation screening or in the sales process? Prior to... property undergoing donation screening or in the sales process. Federal transfers may be authorized prior...
Code of Federal Regulations, 2013 CFR
2013-07-01
... requests personal property that is undergoing donation screening or in the sales process? 102-36.270... agency requests personal property that is undergoing donation screening or in the sales process? Prior to... property undergoing donation screening or in the sales process. Federal transfers may be authorized prior...
Code of Federal Regulations, 2011 CFR
2011-01-01
... requests personal property that is undergoing donation screening or in the sales process? 102-36.270... agency requests personal property that is undergoing donation screening or in the sales process? Prior to... property undergoing donation screening or in the sales process. Federal transfers may be authorized prior...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tessore, Nicolas; Metcalf, R. Benton; Winther, Hans A.
A number of alternatives to general relativity exhibit gravitational screening in the non-linear regime of structure formation. We describe a set of algorithms that can produce weak lensing maps of large scale structure in such theories and can be used to generate mock surveys for cosmological analysis. By analysing a few basic statistics we indicate how these alternatives can be distinguished from general relativity with future weak lensing surveys.
Building a virtual ligand screening pipeline using free software: a survey.
Glaab, Enrico
2016-03-01
Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. © The Author 2015. Published by Oxford University Press.
Building a virtual ligand screening pipeline using free software: a survey
2016-01-01
Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. PMID:26094053
Real-time 3-D X-ray and gamma-ray viewer
NASA Technical Reports Server (NTRS)
Yin, L. I. (Inventor)
1983-01-01
A multi-pinhole aperture lead screen forms an equal plurality of invisible mini-images having dissimilar perspectives of an X-ray and gamma-ray emitting object (ABC) onto a near-earth phosphor layer. This layer provides visible light mini-images directly into a visible light image intensifier. A viewing screen having an equal number of dissimilar perspective apertures distributed across its face in a geometric pattern identical to the lead screen, provides a viewer with a real, pseudoscopic image (A'B'C') of the object with full horizontal and vertical parallax. Alternatively, a third screen identical to viewing screen and spaced apart from a second visible light image intensifier, may be positioned between the first image intensifier and the viewing screen, thereby providing the viewer with a virtual, orthoscopic image (A"B"C") of the object (ABC) with full horizontal and vertical parallax.
Fragment Screening and HIV Therapeutics
Bauman, Joseph D.; Patel, Disha; Arnold, Eddy
2013-01-01
Fragment screening has proven to be a powerful alternative to traditional methods for drug discovery. Biophysical methods, such as X-ray crystallography, NMR spectroscopy, and surface plasmon resonance, are used to screen a diverse library of small molecule compounds. Although compounds identified via this approach have relatively weak affinity, they provide a good platform for lead development and are highly efficient binders with respect to their size. Fragment screening has been utilized for a wide-range of targets, including HIV-1 proteins. Here, we review the fragment screening studies targeting HIV-1 proteins using X-ray crystallography or surface plasmon resonance. These studies have successfully detected binding of novel fragments to either previously established or new sites on HIV-1 protease and reverse transcriptase. In addition, fragment screening against HIV-1 reverse transcriptase has been used as a tool to better understand the complex nature of ligand binding to a flexible target. PMID:21972022
Peer-reviewed, evidence-based summaries on topics including adult and pediatric cancer treatment, supportive and palliative care, screening, prevention, genetics, and complementary and alternative medicine. References to published literature are included.
A review of screening mammography participation and utilization in Canada.
Doyle, G P; Major, D; Chu, C; Stankiewicz, A; Harrison, M L; Pogany, L; Mai, V M; Onysko, J
2011-09-01
Participation rate is an important indicator for a screening program's effectiveness; however, the current approach to measuring participation rate in Canada is not comparable with other countries. The objective of this study is to review the measurement of screening mammography participation in Canada, make international comparisons, and propose alternative methods. Canadian breast cancer screening program data for women aged 50 to 69 years screened between 2004 and 2006 were extracted from the Canadian Breast Cancer Screening Database (CBCSD). The fee-for-services (FSS) mammography data (opportunistic screening mammography) were obtained from the provincial ministries of health. Both screening mammography program participation and utilization were examined over 24 and 30 months. Canada's screening participation rate increases from 39.4% for a 24-month cut-off to 43.6% for a 30-month cut-off. The 24-month mammography utilization rate is 63.1% in Canada, and the 30-month utilization rate is 70.4%. Due to the differences in health service delivery among Canadian provinces, both programmatic participation and overall utilization of mammography at 24 months and 30 months should be monitored.
Beaber, Elisabeth F; Kim, Jane J; Schapira, Marilyn M; Tosteson, Anna N A; Zauber, Ann G; Geiger, Ann M; Kamineni, Aruna; Weaver, Donald L; Tiro, Jasmin A
2015-06-01
General frameworks of the cancer screening process are available, but none directly compare the process in detail across different organ sites. This limits the ability of medical and public health professionals to develop and evaluate coordinated screening programs that apply resources and population management strategies available for one cancer site to other sites. We present a trans-organ conceptual model that incorporates a single screening episode for breast, cervical, and colorectal cancers into a unified framework based on clinical guidelines and protocols; the model concepts could be expanded to other organ sites. The model covers four types of care in the screening process: risk assessment, detection, diagnosis, and treatment. Interfaces between different provider teams (eg, primary care and specialty care), including communication and transfer of responsibility, may occur when transitioning between types of care. Our model highlights across each organ site similarities and differences in steps, interfaces, and transitions in the screening process and documents the conclusion of a screening episode. This model was developed within the National Cancer Institute-funded consortium Population-based Research Optimizing Screening through Personalized Regimens (PROSPR). PROSPR aims to optimize the screening process for breast, cervical, and colorectal cancer and includes seven research centers and a statistical coordinating center. Given current health care reform initiatives in the United States, this conceptual model can facilitate the development of comprehensive quality metrics for cancer screening and promote trans-organ comparative cancer screening research. PROSPR findings will support the design of interventions that improve screening outcomes across multiple cancer sites. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin
2015-11-04
Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25-65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium's accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development.
Singh, Jay P.; Grann, Martin; Lichtenstein, Paul; Långström, Niklas; Fazel, Seena
2012-01-01
Clinical guidelines recommend that violence risk be assessed in schizophrenia. Current approaches are resource-intensive as they employ detailed clinical assessments of dangerousness for most patients. An alternative approach would be to first screen out patients at very low risk of future violence prior to more costly and time-consuming assessments. In order to implement such a stepped strategy, we developed a simple tool to screen out individuals with schizophrenia at very low risk of violent offending. We merged high quality Swedish national registers containing information on psychiatric diagnoses, socio-demographic factors, and violent crime. A cohort of 13,806 individuals with hospital discharge diagnoses of schizophrenia was identified and followed for up to 33 years for violent crime. Cox regression was used to determine risk factors for violent crime and construct the screening tool, the predictive validity of which was measured using four outcome statistics. The instrument was calibrated on 6,903 participants and cross-validated using three independent replication samples of 2,301 participants each. Regression analyses resulted in a tool composed of five items: male sex, previous criminal conviction, young age at assessment, comorbid alcohol abuse, and comorbid drug abuse. At 5 years after discharge, the instrument had a negative predictive value of 0.99 (95% CI = 0.98–0.99), meaning that very few individuals who the tool screened out (n = 2,359 out of original sample of 6,903) were subsequently convicted of a violent offence. Screening out patients who are at very low risk of violence prior to more detailed clinical assessment may assist the risk assessment process in schizophrenia. PMID:22359622
Evaluation of Silicon Nitride for Brayton Turbine Wheel Application
NASA Technical Reports Server (NTRS)
Freedman, Marc R.
2008-01-01
Silicon nitride (Si3N4) is being evaluated as a risk-reduction alternative for a Jupiter Icy Moons Orbiter Brayton turbine wheel in the event that the Prometheus program design requirements exceed the creep strength of the baseline metallic superalloys. Five Si3N4 ceramics, each processed by a different method, were screened based on the Weibull distribution of bend strength at 1700 F (927 C). Three of the Si3N4 ceramics, Honeywell AS800, Kyocera SN282, and Saint-Gobain NT154, had bend strengths in excess of 87 ksi (600 MPa) at 1700 F (927 C). These were chosen for further assessment and consideration for future subcomponent and component fabrication and testing.
Films of Carbon Nanomaterials for Transparent Conductors
Ho, Xinning; Wei, Jun
2013-01-01
The demand for transparent conductors is expected to grow rapidly as electronic devices, such as touch screens, displays, solid state lighting and photovoltaics become ubiquitous in our lives. Doped metal oxides, especially indium tin oxide, are the commonly used materials for transparent conductors. As there are some drawbacks to this class of materials, exploration of alternative materials has been conducted. There is an interest in films of carbon nanomaterials such as, carbon nanotubes and graphene as they exhibit outstanding properties. This article reviews the synthesis and assembly of these films and their post-treatment. These processes determine the film performance and understanding of this platform will be useful for future work to improve the film performance. PMID:28809267
NASA Technical Reports Server (NTRS)
McMillan, R. Andrew; Howard, Jeanie; Zaluzec, Nestor J.; Kagawa, Hiromi K.; Li, Yi-Fen; Paavola, Chad D.; Trent, Jonathan D.
2004-01-01
Self-assembling biomolecules that form highly ordered structures have attracted interest as potential alternatives to conventional lithographic processes for patterning materials. Here we introduce a general technique for patterning materials on the nanoscale using genetically modified protein cage structures called chaperonins that self-assemble into crystalline templates. Constrained chemical synthesis of transition metal nanoparticles is specific to templates genetically functionalized with poly-Histidine sequences. These arrays of materials are ordered by the nanoscale structure of the crystallized protein. This system may be easily adapted to pattern a variety of materials given the rapidly growing list of peptide sequences selected by screening for specificity for inorganic materials.
Vahabi, Mandana; Lofters, Aisha
2016-08-24
Canada has observed significant decreases in incidence and mortality of cervical cancer in recent decades, and this has been attributed to appropriate screening (i.e., the Pap test). However, certain subgroups including Muslim immigrants show higher rates of cervical cancer mortality despite their lower incidence. Low levels of screening have been attributed to such barriers as lack of a family physician, inconvenient clinic hours, having a male physician, and cultural barriers (e.g., modesty, language). HPV self -sampling helps to alleviate many of these barriers. However, little is known about the acceptability of this evidence-based strategy among Muslim women. This study explored Muslim immigrant women's views on cervical cancer screening and the acceptability of HPV self-sampling. An exploratory community-based mixed methods design was used. A convenience sample of 30 women was recruited over a 3-month period (June-August 2015) in the Greater Toronto Area. All were between 21 and 69 years old, foreign-born, self-identified as Muslim, and had good knowledge of English. Data were collected through focus groups. This study provides critical insights about the importance of religious and cultural beliefs in shaping the daily and health care experiences of Muslim women and their cancer screening decisions. Our study showed the deterring impact of beliefs and health practices in home countries on Muslim immigrant women's utilization of screening services. Limited knowledge about cervical cancer and screening guidelines and need for provision of culturally appropriate sexual health information were emphasized. The results revealed that HPV self-sampling provides a favorable alternative model of care to the traditional provider-administered Pap testing for this population. To enhance Muslim immigrant women screening uptake, efforts should made to increase 1) their knowledge of the Canadian health care system and preventive services at the time of entry to Canada, and 2) access to culturally sensitive education programs, female health professionals, and alternative modes of screening like HPV self-sampling. Health professionals need to take an active role in offering screening during health encounters, be educated about sexual health communication with minority women, and be aware of the detrimental impact of preconceived assumptions about sexual activity of Muslim women.
Karami, Pari; Majidi, Mir Reza; Johari-Ahar, Mohammad; Barar, Jaleh; Omidi, Yadollah
2017-06-15
The development of analytical methods that respond to the emerging need to perform rapid 'in situ' analyses of human metabolic pathways (HMPs) demonstrates disposable screen-printed electrodes (SPEs) as an alternative to the traditional tools. In the kynurenine pathway, one of the important HMPs, increased production of kynurenine (Kyn) as a main catabolite of tryptophan (Trp) degradation is involved in the immuno-editing process supporting cancer cells in escaping from the human immune system. In the current study, we demonstrate the development of a screen-printed potentiometric immunosensor for in vitro evaluation of Trp consumption and Kyn production controlled by cancer cells in response to the activated T-lymphocytes. To engineer this immunosensor, uniform layer of carboxylated multiwall carbon nanotubes (MWCNT) was deposited on gold screen-printed electrode (AuSPE), and afterwards monoclonal antibody (mAb) specific to l-kynurenine was covalently conjugated with the MWCNT modified AuSPE. The engineered immunosensor was examined in monitoring Trp consumption and Kyn production in metastatic (Calu-6, NCI-H1299, and HT29) and nonmetastatic (HepG2 and 1321NI) cancer cell lines. Without applying preparation and separation steps, this Trp-Kyn immunosensor offers an improved limit of detection (0.5nM and 120nM for Kyn and Trp detection, respectively) and a broad linear range of detection (LRD: 0.001-1µM and 1-100µM for Kyn, and 0.1-300µM for Trp detection). However, this immunosensor was successfully used for in situ analysis of Kyn that are produced during immuno-editing process in cell culture media, and could reveal that Trp consumption and Kyn production by highly metastatic cancer cells (HT29) were significantly higher than nonmetastatic HepG2 cancer cells. Owing to the screen-printed nature, such kind of biosensors have capability of being integrated into lab-on-a-chip (LOC), microfluidics, and micro total analysis systems. Copyright © 2016 Elsevier B.V. All rights reserved.
The HLA-A*31:01 allele: influence on carbamazepine treatment
Yip, Vincent Lai Ming; Pirmohamed, Munir
2017-01-01
Carbamazepine (CBZ) is an effective anticonvulsant that can sometimes cause hypersensitivity reactions that vary in frequency and severity. Strong associations have been reported between specific human leukocyte antigen (HLA) alleles and susceptibility to CBZ hypersensitivity reactions. Screening for HLA-B*15:02 is mandated in patients from South East Asia because of a strong association with Stevens–Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN). HLA-A*31:01 predisposes to multiple phenotypes of CBZ hypersensitivity including maculopapular exanthema, hypersensitivity syndrome, and SJS/TEN in a range of populations including Europeans, Japanese, South Koreans and Han Chinese, although the effect size varies between the different phenotypes and populations. Between 47 Caucasians and 67 Japanese patients would need to be tested for HLA-A*31:01 in order to avoid a single case of CBZ hypersensitivity. A cost-effectiveness study has demonstrated that HLA-A*31:01 screening would be cost-effective. Patient preference assessment has also revealed that patients prefer pharmacogenetic screening and prescription of alternative anticonvulsants compared to current standard of practice without pharmacogenetic testing. For patients who test positive for HLA-A*31:01, alternative treatments are available. When alternatives have failed or are unavailable, HLA-A*31:01 testing can alert clinicians to 1) patients who are at increased risk of CBZ hypersensitivity who can then be targeted for more intensive monitoring and 2) increase diagnostic certainty in cases where hypersensitivity has already occurred, so patients can be advised to avoid structurally related drugs in the future. On the basis of the current evidence, we would favor screening all patients for HLA-A*31:01 and HLA-B*15:02 prior to starting CBZ therapy. PMID:28203102
Application of Adverse Outcome Pathways to U.S. EPA’s Endocrine Disruptor Screening Program
Noyes, Pamela D.; Casey, Warren M.; Dix, David J.
2017-01-01
Background: The U.S. EPA’s Endocrine Disruptor Screening Program (EDSP) screens and tests environmental chemicals for potential effects in estrogen, androgen, and thyroid hormone pathways, and it is one of the only regulatory programs designed around chemical mode of action. Objectives: This review describes the EDSP’s use of adverse outcome pathway (AOP) and toxicity pathway frameworks to organize and integrate diverse biological data for evaluating the endocrine activity of chemicals. Using these frameworks helps to establish biologically plausible links between endocrine mechanisms and apical responses when those end points are not measured in the same assay. Results: Pathway frameworks can facilitate a weight of evidence determination of a chemical’s potential endocrine activity, identify data gaps, aid study design, direct assay development, and guide testing strategies. Pathway frameworks also can be used to evaluate the performance of computational approaches as alternatives for low-throughput and animal-based assays and predict downstream key events. In cases where computational methods can be validated based on performance, they may be considered as alternatives to specific assays or end points. Conclusions: A variety of biological systems affect apical end points used in regulatory risk assessments, and without mechanistic data, an endocrine mode of action cannot be determined. Because the EDSP was designed to consider mode of action, toxicity pathway and AOP concepts are a natural fit. Pathway frameworks have diverse applications to endocrine screening and testing. An estrogen pathway example is presented, and similar approaches are being used to evaluate alternative methods and develop predictive models for androgen and thyroid pathways. https://doi.org/10.1289/EHP1304 PMID:28934726
A Proven Method for Meeting Export Control Objectives in Postal and Shipping Sectors
2015-02-01
Mellon University for the operation of the Software Engineering Institute, a federally funded research and development center sponsored by the United...Export Control at USPS 5 3.3 Objectives for Improving Export Screening at USPS 6 4 Development of the New Screening Process 7 4.1 “Walking the Model...Export Screening Development Process 10 Figure 2: Induction and Processing of International Mail 10 Figure 3: The Export Screening Process 11
Berkeley Screen: a set of 96 solutions for general macromolecular crystallization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Jose H.; McAndrew, Ryan P.; Tomaleri, Giovani P.
Using statistical analysis of the Biological Macromolecular Crystallization Database, combined with previous knowledge about crystallization reagents, a crystallization screen called the Berkeley Screen has been created. Correlating crystallization conditions and high-resolution protein structures, it is possible to better understand the influence that a particular solution has on protein crystal formation. Ions and small molecules such as buffers and precipitants used in crystallization experiments were identified in electron density maps, highlighting the role of these chemicals in protein crystal packing. The Berkeley Screen has been extensively used to crystallize target proteins from the Joint BioEnergy Institute and the Collaborative Crystallography programmore » at the Berkeley Center for Structural Biology, contributing to several Protein Data Bank entries and related publications. The Berkeley Screen provides the crystallographic community with an efficient set of solutions for general macromolecular crystallization trials, offering a valuable alternative to the existing commercially available screens. The Berkeley Screen provides an efficient set of solutions for general macromolecular crystallization trials.« less
Berkeley Screen: a set of 96 solutions for general macromolecular crystallization
Pereira, Jose H.; McAndrew, Ryan P.; Tomaleri, Giovani P.; ...
2017-09-05
Using statistical analysis of the Biological Macromolecular Crystallization Database, combined with previous knowledge about crystallization reagents, a crystallization screen called the Berkeley Screen has been created. Correlating crystallization conditions and high-resolution protein structures, it is possible to better understand the influence that a particular solution has on protein crystal formation. Ions and small molecules such as buffers and precipitants used in crystallization experiments were identified in electron density maps, highlighting the role of these chemicals in protein crystal packing. The Berkeley Screen has been extensively used to crystallize target proteins from the Joint BioEnergy Institute and the Collaborative Crystallography programmore » at the Berkeley Center for Structural Biology, contributing to several Protein Data Bank entries and related publications. The Berkeley Screen provides the crystallographic community with an efficient set of solutions for general macromolecular crystallization trials, offering a valuable alternative to the existing commercially available screens. The Berkeley Screen provides an efficient set of solutions for general macromolecular crystallization trials.« less
Sharp, Linda; Tilson, Lesley; Whyte, Sophie; Ceilleachair, Alan O; Walsh, Cathal; Usher, Cara; Tappenden, Paul; Chilcott, James; Staines, Anthony; Barry, Michael; Comber, Harry
2013-03-19
Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55-74 years, and (c) biennial faecal immunochemical tests (FIT) at 55-74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55-64 years) and staggered age-based roll-out across the 55-74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55-74). FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381-1,053 with FSIG-based, and 967-1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning.
Shinozaki, Takashi; Watanabe, Ryuichi; Kawatsu, Kentaro; Sakurada, Kiyonari; Takahi, Shinya; Ueno, Ken-ichi; Matsushima, Ryoji; Suzuki, Toshiyuki
2013-01-01
We investigated the applicability of enzyme-linked immunosorbent assay (PSP-ELISA) using a monoclonal antibody against paralytic shellfish toxins (PST) for screening oysters collected at several coastal areas in Kumamoto prefecture, Japan. Oysters collected between 2007 and 2010 were analyzed by PSP-ELISA. As an alternative calibrant, a naturally contaminated oyster extract was used to quantify toxins in the oyster samples. The toxicity of the calibrant oyster extract determined by the official testing method, mouse bioassay (MBA), was 4 MU/g. Oyster samples collected over 3 years showed a similar toxin profile to the alternative standard, resulting in good agreement between the PSP-ELISA and the MBA. The PSP-ELISA method was better than the MBA in terms of sensitivity, indicating that it may be useful for earlier warning of contamination of oysters by PST in the distinct coastal areas. To use the PSP-ELISA as a screening method prior to MBA, we finally set a screening level at 2 MU/g PSP-ELISA for oyster monitoring in Kumamoto prefecture. We confirmed that there were on samples exceeding the quarantine level (4 MU/g) in MBA among samples quantified as below the screening level by the PSP-ELISA. It was concluded that the use of PSP-ELISA could reduce the numbers of animals needed for MBA testing.
Etzioni, Ruth; Gulati, Roman
2013-04-01
In our article about limitations of basing screening policy on screening trials, we offered several examples of ways in which modeling, using data from large screening trials and population trends, provided insights that differed somewhat from those based only on empirical trial results. In this editorial, we take a step back and consider the general question of whether randomized screening trials provide the strongest evidence for clinical guidelines concerning population screening programs. We argue that randomized trials provide a process that is designed to protect against certain biases but that this process does not guarantee that inferences based on empirical results from screening trials will be unbiased. Appropriate quantitative methods are key to obtaining unbiased inferences from screening trials. We highlight several studies in the statistical literature demonstrating that conventional survival analyses of screening trials can be misleading and list a number of key questions concerning screening harms and benefits that cannot be answered without modeling. Although we acknowledge the centrality of screening trials in the policy process, we maintain that modeling constitutes a powerful tool for screening trial interpretation and screening policy development.
NASA Technical Reports Server (NTRS)
Samsa, M.
1980-01-01
An important effort is the Satellite Power System (SPS) comparative Assessment is the selection and characterization of alternative technologies to be compared with the SPS concept. The ground rules, criteria, and screening procedure applied in the selection of those alternative technologies are summarized. The final set of central station alternatives selected for comparison with the SPS concept includes: (1) light water reactor with improved fuel utilization, (2) conventional coal combustion with improved environmental controls, (3) open cycle gas turbine with integral low Btu gasifier, (4) terrestrial photovoltaic, (5) liquid metal fast breeder reactor, and (6) magnetic confinement fusion.
ERIC Educational Resources Information Center
Shin, Dong-Hee; An, Hyeri; Kim, Jang Hyun
2016-01-01
The use of a second screen can enhance information processing and the execution of search tasks within a given period. In this study, we examined the learner's attentional shift (AS) between two screens and controlled secondary tasks (STs) in the media multitasking setting and its effect on the learning process. In particular, we analyzed how…
Current and future needs for developmental toxicity testing.
Makris, Susan L; Kim, James H; Ellis, Amy; Faber, Willem; Harrouk, Wafa; Lewis, Joseph M; Paule, Merle G; Seed, Jennifer; Tassinari, Melissa; Tyl, Rochelle
2011-10-01
A review is presented of the use of developmental toxicity testing in the United States and international regulatory assessment of human health risks associated with exposures to pharmaceuticals (human and veterinary), chemicals (agricultural, industrial, and environmental), food additives, cosmetics, and consumer products. Developmental toxicology data are used for prioritization and screening of pharmaceuticals and chemicals, for evaluating and labeling of pharmaceuticals, and for characterizing hazards and risk of exposures to industrial and environmental chemicals. The in vivo study designs utilized in hazard characterization and dose-response assessment for developmental outcomes have not changed substantially over the past 30 years and have served the process well. Now there are opportunities to incorporate new technologies and approaches to testing into the existing assessment paradigm, or to apply innovative approaches to various aspects of risk assessment. Developmental toxicology testing can be enhanced by the refinement or replacement of traditional in vivo protocols, including through the use of in vitro assays, studies conducted in alternative nonmammalian species, the application of new technologies, and the use of in silico models. Potential benefits to the current regulatory process include the ability to screen large numbers of chemicals quickly, with the commitment of fewer resources than traditional toxicology studies, and to refine the risk assessment process through an enhanced understanding of the mechanisms of developmental toxicity and their relevance to potential human risk. As the testing paradigm evolves, the ability to use developmental toxicology data to meet diverse critical regulatory needs must be retained. © 2011 Wiley Periodicals, Inc.
Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio
2012-01-01
The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
Trefzer, Axel; Jungmann, Volker; Molnár, István; Botejue, Ajit; Buckel, Dagmar; Frey, Gerhard; Hill, D. Steven; Jörg, Mario; Ligon, James M.; Mason, Dylan; Moore, David; Pachlatko, J. Paul; Richardson, Toby H.; Spangenberg, Petra; Wall, Mark A.; Zirkle, Ross; Stege, Justin T.
2007-01-01
Discovery of the CYP107Z subfamily of cytochrome P450 oxidases (CYPs) led to an alternative biocatalytic synthesis of 4″-oxo-avermectin, a key intermediate for the commercial production of the semisynthetic insecticide emamectin. However, under industrial process conditions, these wild-type CYPs showed lower yields due to side product formation. Molecular evolution employing GeneReassembly was used to improve the regiospecificity of these enzymes by a combination of random mutagenesis, protein structure-guided site-directed mutagenesis, and recombination of multiple natural and synthetic CYP107Z gene fragments. To assess the specificity of CYP mutants, a miniaturized, whole-cell biocatalytic reaction system that allowed high-throughput screening of large numbers of variants was developed. In an iterative process consisting of four successive rounds of GeneReassembly evolution, enzyme variants with significantly improved specificity for the production of 4″-oxo-avermectin were identified; these variants could be employed for a more economical industrial biocatalytic process to manufacture emamectin. PMID:17483257
Apparel Research Network (ARN); Apparel Order Processing Module (AOPM): Field User Manual, Version 1
1997-09-30
changes. Cancel Button Closes the Site Information Screen, abandoning changes. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official...on the Ordering Official Information Screen. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official Information Screen (Jjj
Martin, Todd M.
2017-01-01
The goal of alternatives assessment (AA) is to facilitate a comparison of alternatives to a chemical of concern, resulting in the identification of safer alternatives. A two stage methodology for comparing chemical alternatives was developed. In the first stage, alternatives are compared using a variety of human health effects, ecotoxicity, and physicochemical properties. Hazard profiles are completed using a variety of online sources and quantitative structure activity relationship models. In the second stage, alternatives are evaluated utilizing an exposure/risk assessment over the entire life cycle. Exposure values are calculated using screening-level near-field and far-field exposure models. The second stage allows one to more accurately compare potential exposure to each alternative and consider additional factors that may not be obvious from separate binned persistence, bioaccumulation, and toxicity scores. The methodology was utilized to compare phosphate-based alternatives for decabromodiphenyl ether (decaBDE) in electronics applications. PMID:29333139
Methodologies for processing plant material into acceptable food on a small scale
NASA Technical Reports Server (NTRS)
Parks, Thomas R.; Bindon, John N.; Bowles, Anthony J. G.; Golbitz, Peter; Lampi, Rauno A.; Marquardt, Robert F.
1994-01-01
Based on the Controlled Environment Life Support System (CELSS) production of only four crops, wheat, white potatoes, soybeans, and sweet potatoes; a crew size of twelve; a daily planting/harvesting regimen; and zero-gravity conditions, estimates were made on the quantity of food that would need to be grown to provide adequate nutrition; and the corresponding amount of biomass that would result. Projections were made of the various types of products that could be made from these crops, the unit operations that would be involved, and what menu capability these products could provide. Equipment requirements to perform these unit operations were screened to identify commercially available units capable of operating (or being modified to operate) under CELSS/zero-gravity conditions. Concept designs were developed for those equipment needs for which no suitable units were commercially available. Prototypes of selected concept designs were constructed and tested on a laboratory scale, as were selected commercially available units. This report discusses the practical considerations taken into account in the various design alternatives, some of the many product/process factors that relate to equipment development, and automation alternatives. Recommendations are made on both general and specific areas in which it was felt additional investigation would benefit CELSS missions.
Fungal Beta-Glucosidases: A Bottleneck in Industrial Use of Lignocellulosic Materials
Sørensen, Annette; Lübeck, Mette; Lübeck, Peter S.; Ahring, Birgitte K.
2013-01-01
Profitable biomass conversion processes are highly dependent on the use of efficient enzymes for lignocellulose degradation. Among the cellulose degrading enzymes, beta-glucosidases are essential for efficient hydrolysis of cellulosic biomass as they relieve the inhibition of the cellobiohydrolases and endoglucanases by reducing cellobiose accumulation. In this review, we discuss the important role beta-glucosidases play in complex biomass hydrolysis and how they create a bottleneck in industrial use of lignocellulosic materials. An efficient beta-glucosidase facilitates hydrolysis at specified process conditions, and key points to consider in this respect are hydrolysis rate, inhibitors, and stability. Product inhibition impairing yields, thermal inactivation of enzymes, and the high cost of enzyme production are the main obstacles to commercial cellulose hydrolysis. Therefore, this sets the stage in the search for better alternatives to the currently available enzyme preparations either by improving known or screening for new beta-glucosidases. PMID:24970184
Ink jet assisted metallization for low cost flat plate solar cells
NASA Technical Reports Server (NTRS)
Teng, K. F.; Vest, R. W.
1987-01-01
Computer-controlled ink-jet-assisted metallization of the front surface of solar cells with metalorganic silver inks offers a maskless alternative method to conventional photolithography and screen printing. This method can provide low cost, fine resolution, reduced process complexity, avoidance of degradation of the p-n junction by firing at lower temperature, and uniform line film on rough surface of solar cells. The metallization process involves belt furnace firing and thermal spiking. With multilayer ink jet printing and firing, solar cells of about 5-6 percent efficiency without antireflection (AR) coating can be produced. With a titanium thin-film underlayer as an adhesion promoter, solar cells of average efficiency 8.08 percent without AR coating can be obtained. This efficiency value is approximately equal to that of thin-film solar cells of the same lot. Problems with regard to lower inorganic content of the inks and contact resistance are noted.
An update in breast cancer screening and management.
Warrier, Sanjay; Tapia, Grace; Goltsman, David; Beith, Jane
2016-01-01
This article provides an overview of the main controversies in a number of key areas of breast cancer management. Relevant studies that have contributed to guide the treatment of this heterogeneous disease in the field of breast screening, surgery, chemotherapy and radiotherapy are highlighted. Mammography and ultrasound are the main methods of breast screening. MRI and tomosynthesis are emerging as new screening tools for a selected group of breast cancer patients. From a surgical perspective, oncoplastic techniques and neoadjuvant chemotherapy are improving cosmetic results in breast-conserving surgery. For high-risk patients, controversies still remain regarding prophylactic mastectomies. Finally, the appropriate management of the axilla continues evolving with the increasing role of radiotherapy as an alternative treatment to axillary dissection.
A CRISPR toolbox to study virus–host interactions
Puschnik, Andreas S.; Majzoub, Karim; Ooi, Yaw Shin; Carette, Jan E.
2018-01-01
Viruses depend on their hosts to complete their replication cycles; they exploit cellular receptors for entry and hijack cellular functions to replicate their genome, assemble progeny virions and spread. Recently, genome-scale CRISPR–Cas screens have been used to identify host factors that are required for virus replication, including the replication of clinically relevant viruses such as Zika virus, West Nile virus, dengue virus and hepatitis C virus. In this Review, we discuss the technical aspects of genome-scale knockout screens using CRISPR–Cas technology, and we compare these screens with alternative genetic screening technologies. The relative ease of use and reproducibility of CRISPR–Cas make it a powerful tool for probing virus–host interactions and for identifying new antiviral targets. PMID:28420884
Screening in perturbative approaches to LSS
Fasiello, Matteo; Vlah, Zvonimir
2017-08-24
A specific value for the cosmological constant Λ can account for late-time cosmic acceleration. However, motivated by the so-called cosmological constant problem(s), several alternative mechanisms have been explored. To date, a host of well-studied dynamical dark energy and modified gravity models exists. Going beyond ΛCDM often comes with additional degrees of freedom (dofs). For these to pass existing observational tests, an efficient screening mechanism must be in place. Furthermore, the linear and quasi-linear regimes of structure formation are ideal probes of such dofs and can capture the onset of screening. We propose here a semi-phenomenological “filter” to account for screeningmore » dynamics on LSS observables, with special emphasis on Vainshtein-type screening.« less
An Update in Breast Cancer Screening and Management
Warrier, Sanjay; Tapia, Grace; Goltsman, David; Beith, Jane
2015-01-01
This article provides an overview of the main controversies in a number of key areas of breast cancer management. Relevant studies that have contributed to guide the treatment of this heterogeneous disease in the field of breast screening, surgery, chemotherapy and radiotherapy are highlighted. Mammography and ultrasound are the main methods of breast screening. MRI and tomosynthesis are emerging as new screening tools for a selected group of breast cancer patients. From a surgical perspective, oncoplastic techniques and neoadjuvant chemotherapy are improving cosmetic results in breast-conserving surgery. For high-risk patients, controversies still remain regarding prophylactic mastectomies. Finally, the appropriate management of the axilla continues evolving with the increasing role of radiotherapy as an alternative treatment to axillary dissection. PMID:26689336
NASA Technical Reports Server (NTRS)
Brock, T. W.; Field, M. B.
1979-01-01
Low-melting phosphate and borate glasses were screen printed on silicon wafers and heated to form n and p junctions. Data on surface appearance, sheet resistance and junction depth are presented. Similar data are reported for vapor phase transport from sintered aluminum metaphosphate and boron-containing glass-ceramic solid sources. Simultaneous diffusion of an N(+) layer with screen-printed glass and a p(+) layer with screen-printed Al alloy paste was attempted. No p(+) back surface field formation was achieved. Some good cells were produced but the heating in an endless-belt furnace caused a large scatter in sheet resistance and junction depth for three separate lots of wafers.
ERIC Educational Resources Information Center
Harpp, David N.; Snyder, James P.
1977-01-01
Describes a lecture teaching technique called lap-dissolve projection in which two slide projectors are operated alternately so that one visual image fades away while the next appears on the same screen area. (MLH)
... can be exacerbated by light sources such as computer screens or fluorescent lights. Use a flicker-free ... cubicle shield Allow frequent breaks from tasks involving computer Provide alternative light sources: Replace fluorescent lights with ...
Gluten screening of several dietary supplements by immunochromatographic assay.
Oancea, Simona; Wagner, Adriana; Cîrstea, Elena; Sima, Mirela
2011-01-01
Celiac disease (CD) is a chronic intestinal disorder of public health concern caused by gluten ingestion in sensitive individuals. Gluten is a protein found not only in gluten-containing food but also as normal component of drugs and dietary supplements. Detection of gluten in dietary supplements is a very important task required for establishing their gluten status, which is highly important for the safety of products consumed by CD and gluten-sensitive patients. In this paper, we investigated the presence of gluten in twenty one common dietary supplements from the national market using the immunochromatographic assay. This visual assay proved to be an efficient rapid tool for gluten screening as an alternative to the ELISA techniques. The results have shown the presence of gluten in 23.8% of the investigated samples (vitamins, minerals, plant extracts, probiotics supplements, lactoferrin, propolis supplements). The results provide information which may contribute to the completion of the existing lists of gluten-free pharmaceuticals. It is known that for CD patients obtaining accurate information about the gluten content of a particular item is a difficult and time-consuming process.
Ramkumar, Vidya; Selvakumar, K; Vanaja, C S; Hall, James W; Nagarajan, Roopa; Neethi, J
2016-10-01
Tele-diagnostic audiological testing in a hearing screening program for infants and young children is a novel practice, and this study is the first to explore its application in a rural community. It is important to understand parental perceptions and confidence when introducing a new process such as tele-audiological diagnostic testing in rural areas. A questionnaire with 17 rater-administered items was designed to elicit comments concerning the quality of tele-hearing testing and video-conferencing, access to tele-hearing testing, and parents' attitudes regarding tele-hearing testing in the village. The questionnaire was administered by an audiologist not involved in tele-diagnostic testing to avoid bias. Parents perceived tele-hearing testing as equal in quality to in-person testing. Technical factors such as good video-conferencing quality and logistical factors such as ease of access due to reasonable travel time to testing facility could have influenced these perceptions. While these results show tele-hearing testing is an acceptable alternative, occasional poor signal quality should be addressed prior to large-scale implementation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Critical screening in the one- and two-electron Yukawa atoms
NASA Astrophysics Data System (ADS)
Montgomery, H. E.; Sen, K. D.; Katriel, Jacob
2018-02-01
The one- and two-electron Yukawa atoms, also referred to as the Debye-Hückel or screened Coulomb atoms, have been topics of considerable interest both for intrinsic reasons and because of their relevance to terrestrial and astrophysical plasmas. At sufficiently high screening the one-electron Yukawa atom ceases to be bound. Some calculations appeared to suggest that as the screening increases in the ground state of the two-electron Yukawa atom (in which both the one-particle attraction and the interparticle repulsion are screened) the two electrons are detached simultaneously, at the same screening constant at which the one-electron atom becomes unbound. Our results rule this scenario out, offering an alternative that is not less interesting. In particular, it is found that for Z <1 a mild amount of screening actually increases the binding energy of the second electron. At the nuclear charge Zc≈0.911028 ... , at which the bare Coulomb two-electron atom becomes unbound, and even over a range of lower nuclear charges, an appropriate amount of screening gives rise to a bound two-electron system.
Basch, Charles E; Zybert, Patricia; Wolf, Randi L; Basch, Corey H; Ullman, Ralph; Shmukler, Celia; King, Fionnuala; Neugut, Alfred I; Shea, Steven
2015-10-01
This randomized controlled trial assessed different educational approaches for increasing colorectal cancer screening uptake in a sample of primarily non-US born urban minority individuals, over aged 50, with health insurance, and out of compliance with screening guidelines. In one group, participants were mailed printed educational material (n = 180); in a second, participants' primary care physicians received academic detailing to improve screening referral and follow-up practices (n = 185); in a third, physicians received academic detailing and participants received tailored telephone education (n = 199). Overall, 21.5% of participants (n = 121) received appropriate screening within one year of randomization. There were no statistically significant pairwise differences between groups in screening rate. Among those 60 years of age or older, however, the detailing plus telephone education group had a higher screening rate than the print group (27.3 vs. 7.7%, p = .02). Different kinds of interventions will be required to increase colorectal cancer screening among the increasingly small population segment that remains unscreened. ClinicalTrials.gov Identifier: NCT02392143.
7 CFR 361.8 - Cleaning of imported seed and processing of certain Canadian-origin screenings.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 5 2014-01-01 2014-01-01 false Cleaning of imported seed and processing of certain... SCREENINGS UNDER THE FEDERAL SEED ACT § 361.8 Cleaning of imported seed and processing of certain Canadian... compliance agreement for the cleaning of imported seed or processing of otherwise prohibited screenings from...
7 CFR 361.8 - Cleaning of imported seed and processing of certain Canadian-origin screenings.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 5 2012-01-01 2012-01-01 false Cleaning of imported seed and processing of certain... SCREENINGS UNDER THE FEDERAL SEED ACT § 361.8 Cleaning of imported seed and processing of certain Canadian... compliance agreement for the cleaning of imported seed or processing of otherwise prohibited screenings from...
7 CFR 361.8 - Cleaning of imported seed and processing of certain Canadian-origin screenings.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 5 2013-01-01 2013-01-01 false Cleaning of imported seed and processing of certain... SCREENINGS UNDER THE FEDERAL SEED ACT § 361.8 Cleaning of imported seed and processing of certain Canadian... compliance agreement for the cleaning of imported seed or processing of otherwise prohibited screenings from...
7 CFR 361.8 - Cleaning of imported seed and processing of certain Canadian-origin screenings.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Cleaning of imported seed and processing of certain... SCREENINGS UNDER THE FEDERAL SEED ACT § 361.8 Cleaning of imported seed and processing of certain Canadian... compliance agreement for the cleaning of imported seed or processing of otherwise prohibited screenings from...
7 CFR 361.8 - Cleaning of imported seed and processing of certain Canadian-origin screenings.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 5 2011-01-01 2011-01-01 false Cleaning of imported seed and processing of certain... SCREENINGS UNDER THE FEDERAL SEED ACT § 361.8 Cleaning of imported seed and processing of certain Canadian... compliance agreement for the cleaning of imported seed or processing of otherwise prohibited screenings from...
Gray, Ewan; Donten, Anna; Karssemeijer, Nico; van Gils, Carla; Evans, D Gareth; Astley, Sue; Payne, Katherine
2017-09-01
To identify the incremental costs and consequences of stratified national breast screening programs (stratified NBSPs) and drivers of relative cost-effectiveness. A decision-analytic model (discrete event simulation) was conceptualized to represent four stratified NBSPs (risk 1, risk 2, masking [supplemental screening for women with higher breast density], and masking and risk 1) compared with the current UK NBSP and no screening. The model assumed a lifetime horizon, the health service perspective to identify costs (£, 2015), and measured consequences in quality-adjusted life-years (QALYs). Multiple data sources were used: systematic reviews of effectiveness and utility, published studies reporting costs, and cohort studies embedded in existing NBSPs. Model parameter uncertainty was assessed using probabilistic sensitivity analysis and one-way sensitivity analysis. The base-case analysis, supported by probabilistic sensitivity analysis, suggested that the risk stratified NBSPs (risk 1 and risk-2) were relatively cost-effective when compared with the current UK NBSP, with incremental cost-effectiveness ratios of £16,689 per QALY and £23,924 per QALY, respectively. Stratified NBSP including masking approaches (supplemental screening for women with higher breast density) was not a cost-effective alternative, with incremental cost-effectiveness ratios of £212,947 per QALY (masking) and £75,254 per QALY (risk 1 and masking). When compared with no screening, all stratified NBSPs could be considered cost-effective. Key drivers of cost-effectiveness were discount rate, natural history model parameters, mammographic sensitivity, and biopsy rates for recalled cases. A key assumption was that the risk model used in the stratification process was perfectly calibrated to the population. This early model-based cost-effectiveness analysis provides indicative evidence for decision makers to understand the key drivers of costs and QALYs for exemplar stratified NBSP. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Evaluation of an enhanced gravity-based fine-coal circuit for high-sulfur coal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, M.K.; Samal, A.R.; Palit, A.
One of the main objectives of this study was to evaluate a fine-coal cleaning circuit using an enhanced gravity separator specifically for a high sulfur coal application. The evaluation not only included testing of individual unit operations used for fine-coal classification, cleaning and dewatering, but also included testing of the complete circuit simultaneously. At a scale of nearly 2 t/h, two alternative circuits were evaluated to clean a minus 0.6-mm coal stream utilizing a 150-mm-diameter classifying cyclone, a linear screen having a projected surface area of 0.5 m{sup 2}, an enhanced gravity separator having a bowl diameter of 250 mmmore » and a screen-bowl centrifuge having a bowl diameter of 500 mm. The cleaning and dewatering components of both circuits were the same; however, one circuit used a classifying cyclone whereas the other used a linear screen as the classification device. An industrial size coal spiral was used to clean the 2- x 0.6-mm coal size fraction for each circuit to estimate the performance of a complete fine-coal circuit cleaning a minus 2-mm particle size coal stream. The 'linear screen + enhanced gravity separator + screen-bowl circuit' provided superior sulfur and ash-cleaning performance to the alternative circuit that used a classifying cyclone in place of the linear screen. Based on these test data, it was estimated that the use of the recommended circuit to treat 50 t/h of minus 2-mm size coal having feed ash and sulfur contents of 33.9% and 3.28%, respectively, may produce nearly 28.3 t/h of clean coal with product ash and sulfur contents of 9.15% and 1.61 %, respectively.« less
ERIC Educational Resources Information Center
Dwyer, Daniel J.
Designed to assess the effect of alternative display (CRT) screen sizes and resolution levels on user ability to identify and locate printed circuit (PC) board points, this study is the first in a protracted research program on the legibility of graphics in computer-based job aids. Air Force maintenance training pipeline students (35 male and 1…
Caley, Matthew; Wall, Ivan B; Peake, Matthew; Kipling, David; Giles, Peter; Thomas, David W; Stephens, Phil
2018-03-27
Background : Chronic skin wounds are a growing financial burden for healthcare providers, causing discomfort/immobility to patients. Whilst animal chronic wound models have been developed to allow for mechanistic studies and to develop/test potential therapies, such systems are not good representations of the human chronic wound state. As an alternative, human chronic wound fibroblasts (CWFs) have permitted an insight into the dysfunctional cellular mechanisms that are associated with these wounds. However, such cells strains have a limited replicative lifespan and therefore a limited reproducibility/usefulness. Objectives : To develop/characterise immortalised cell lines of CWF and patient-matched normal fibroblasts (NFs). Methods and Results : Immortalisation with human telomerase resulted in both CWF and NF proliferating well beyond their replicative senescence end-point (respective cell strains senesced as normal). Gene expression analysis demonstrated that, whilst proliferation-associated genes were up-regulated in the cell lines (as would be expected), the immortalisation process did not significantly affect the disease-specific genotype. Immortalised CWF (as compared to NF) also retained a distinct impairment in their wound repopulation potential (in line with CWF cell strains). Conclusions : These novel CWF cell lines are a credible animal alternative and could be a valuable research tool for understanding both the aetiology of chronic skin wounds and for therapeutic pre-screening.
Barbara, Joanna E; Castro-Perez, Jose M
2011-10-30
Electrophilic reactive metabolite screening by liquid chromatography/mass spectrometry (LC/MS) is commonly performed during drug discovery and early-stage drug development. Accurate mass spectrometry has excellent utility in this application, but sophisticated data processing strategies are essential to extract useful information. Herein, a unified approach to glutathione (GSH) trapped reactive metabolite screening with high-resolution LC/TOF MS(E) analysis and drug-conjugate-specific in silico data processing was applied to rapid analysis of test compounds without the need for stable- or radio-isotope-labeled trapping agents. Accurate mass defect filtering (MDF) with a C-heteroatom dealkylation algorithm dynamic with mass range was compared to linear MDF and shown to minimize false positive results. MS(E) data-filtering, time-alignment and data mining post-acquisition enabled detection of 53 GSH conjugates overall formed from 5 drugs. Automated comparison of sample and control data in conjunction with the mass defect filter enabled detection of several conjugates that were not evident with mass defect filtering alone. High- and low-energy MS(E) data were time-aligned to generate in silico product ion spectra which were successfully applied to structural elucidation of detected GSH conjugates. Pseudo neutral loss and precursor ion chromatograms derived post-acquisition demonstrated 50.9% potential coverage, at best, of the detected conjugates by any individual precursor or neutral loss scan type. In contrast with commonly applied neutral loss and precursor-based techniques, the unified method has the advantage of applicability across different classes of GSH conjugates. The unified method was also successfully applied to cyanide trapping analysis and has potential for application to alternate trapping agents. Copyright © 2011 John Wiley & Sons, Ltd.
Cost analysis of colorectal cancer screening with CT colonography in Italy.
Mantellini, Paola; Lippi, Giuseppe; Sali, Lapo; Grazzini, Grazia; Delsanto, Silvia; Mallardi, Beatrice; Falchini, Massimo; Castiglione, Guido; Carozzi, Francesca Maria; Mascalchi, Mario; Milani, Stefano; Ventura, Leonardo; Zappa, Marco
2018-06-01
Unit costs of screening CT colonography (CTC) can be useful for cost-effectiveness analyses and for health care decision-making. We evaluated the unit costs of CTC as a primary screening test for colorectal cancer in the setting of a randomized trial in Italy. Data were collected within the randomized SAVE trial. Subjects were invited to screening CTC by mail and requested to have a pre-examination consultation. CTCs were performed with 64- and 128-slice CT scanners after reduced or full bowel preparation. Activity-based costing was used to determine unit costs per-process, per-participant to screening CTC, and per-subject with advanced neoplasia. Among 5242 subjects invited to undergo screening CTC, 1312 had pre-examination consultation and 1286 ultimately underwent CTC. Among 129 subjects with a positive CTC, 126 underwent assessment colonoscopy and 67 were ultimately diagnosed with advanced neoplasia (i.e., cancer or advanced adenoma). Cost per-participant of the entire screening CTC pathway was €196.80. Average cost per-participant for the screening invitation process was €17.04 and €9.45 for the pre-examination consultation process. Average cost per-participant of the CTC execution and reading process was €146.08 and of the diagnostic assessment colonoscopy process was €24.23. Average cost per-subject with advanced neoplasia was €3777.30. Cost of screening CTC was €196.80 per-participant. Our data suggest that the more relevant cost of screening CTC, amenable of intervention, is related to CTC execution and reading process.
Energy-Efficient Bioalcohol Recovery by Gel Stripping
NASA Astrophysics Data System (ADS)
Godbole, Rutvik; Ma, Lan; Hedden, Ronald
2014-03-01
Design of energy-efficient processes for recovering butanol and ethanol from dilute fermentations is a key challenge facing the biofuels industry due to the high energy consumption of traditional multi-stage distillation processes. Gel stripping is an alternative purification process by which a dilute alcohol is stripped from the fermentation product by passing it through a packed bed containing particles of a selectively absorbent polymeric gel material. The gel must be selective for the alcohol, while swelling to a reasonable degree in dilute alcohol-water mixtures. To accelerate materials optimization, a combinatorial approach is taken to screen a matrix of copolymer gels having orthogonal gradients in crosslinker concentration and hydrophilicity. Using a combination of swelling in pure solvents, the selectivity and distribution coefficients of alcohols in the gels can be predicted based upon multi-component extensions of Flory-Rehner theory. Predictions can be validated by measuring swelling in water/alcohol mixtures and conducting h HPLC analysis of the external liquid. 95% + removal of butanol from dilute aqueous solutions has been demonstrated, and a mathematical model of the unsteady-state gel stripping process has been developed. NSF CMMI Award 1335082.
Sagari, Akira; Iso, Naoki; Moriuchi, Takefumi; Ogahara, Kakuya; Kitajima, Eiji; Tanaka, Koji; Tabira, Takayuki; Higashi, Toshio
2015-01-01
Studies of cerebral hemodynamics during motor learning have mostly focused on neurorehabilitation interventions and their effectiveness. However, only a few imaging studies of motor learning and the underlying complex cognitive processes have been performed. We measured cerebral hemodynamics using near-infrared spectroscopy (NIRS) in relation to acquisition patterns of motor skills in healthy subjects using character entry into a touch-screen terminal. Twenty healthy, right-handed subjects who had no previous experience with character entry using a touch-screen terminal participated in this study. They were asked to enter the characters of a randomly formed Japanese syllabary into the touch-screen terminal. All subjects performed the task with their right thumb for 15 s alternating with 25 s of rest for 30 repetitions. Performance was calculated by subtracting the number of incorrect answers from the number of correct answers, and gains in motor skills were evaluated according to the changes in performance across cycles. Behavioral and oxygenated hemoglobin concentration changes across task cycles were analyzed using Spearman's rank correlations. Performance correlated positively with task cycle, thus confirming motor learning. Hemodynamic activation over the left sensorimotor cortex (SMC) showed a positive correlation with task cycle, whereas activations over the right prefrontal cortex (PFC) and supplementary motor area (SMA) showed negative correlations. We suggest that increases in finger momentum with motor learning are reflected in the activity of the left SMC. We further speculate that the right PFC and SMA were activated during the early phases of motor learning, and that this activity was attenuated with learning progress.
Scholz, S; Renner, P; Belanger, S E; Busquet, F; Davi, R; Demeneix, B A; Denny, J S; Léonard, M; McMaster, M E; Villeneuve, D L; Embry, M R
2013-01-01
Endocrine disruption is considered a highly relevant hazard for environmental risk assessment of chemicals, plant protection products, biocides and pharmaceuticals. Therefore, screening tests with a focus on interference with estrogen, androgen, and thyroid hormone pathways in fish and amphibians have been developed. However, they use a large number of animals and short-term alternatives to animal tests would be advantageous. Therefore, the status of alternative assays for endocrine disruption in fish and frogs was assessed by a detailed literature analysis. The aim was to (i) determine the strengths and limitations of alternative assays and (ii) present conclusions regarding chemical specificity, sensitivity, and correlation with in vivo data. Data from 1995 to present were collected related to the detection/testing of estrogen-, androgen-, and thyroid-active chemicals in the following test systems: cell lines, primary cells, fish/frog embryos, yeast and cell-free systems. The review shows that the majority of alternative assays measure effects directly mediated by receptor binding or resulting from interference with hormone synthesis. Other mechanisms were rarely analysed. A database was established and used for a quantitative and comparative analysis. For example, a high correlation was observed between cell-free ligand binding and cell-based reporter cell assays, between fish and frog estrogenic data and between fish embryo tests and in vivo reproductive effects. It was concluded that there is a need for a more systematic study of the predictive capacity of alternative tests and ways to reduce inter- and intra-assay variability.
Crockford, Christopher; Newton, Judith; Lonergan, Katie; Madden, Caoifa; Mays, Iain; O'Sullivan, Meabhdh; Costello, Emmet; Pinto-Grau, Marta; Vajda, Alice; Heverin, Mark; Pender, Niall; Al-Chalabi, Ammar; Hardiman, Orla; Abrahams, Sharon
2018-02-01
Cognitive impairment affects approximately 50% of people with amyotrophic lateral sclerosis (ALS). Research has indicated that impairment may worsen with disease progression. The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) was designed to measure neuropsychological functioning in ALS, with its alternate forms (ECAS-A, B, and C) allowing for serial assessment over time. The aim of the present study was to establish reliable change scores for the alternate forms of the ECAS, and to explore practice effects and test-retest reliability of the ECAS's alternate forms. Eighty healthy participants were recruited, with 57 completing two and 51 completing three assessments. Participants were administered alternate versions of the ECAS serially (A-B-C) at four-month intervals. Intra-class correlation analysis was employed to explore test-retest reliability, while analysis of variance was used to examine the presence of practice effects. Reliable change indices (RCI) and regression-based methods were utilized to establish change scores for the ECAS alternate forms. Test-retest reliability was excellent for ALS Specific, ALS Non-Specific, and ECAS Total scores of the combined ECAS A, B, and C (all > .90). No significant practice effects were observed over the three testing sessions. RCI and regression-based methods produced similar change scores. The alternate forms of the ECAS possess excellent test-retest reliability in a healthy control sample, with no significant practice effects. The use of conservative RCI scores is recommended. Therefore, a change of ≥8, ≥4, and ≥9 for ALS Specific, ALS Non-Specific, and ECAS Total score is required for reliable change.
Rein, David B; Wittenborn, John S; Zhang, Xinzhi; Allaire, Benjamin A; Song, Michael S; Klein, Ronald; Saaddine, Jinan B
2011-01-01
Objective To determine whether biennial eye evaluation or telemedicine screening are cost-effective alternatives to current recommendations for the estimated 10 million people aged 30–84 with diabetes but no or minimal diabetic retinopathy. Data Sources United Kingdom Prospective Diabetes Study, National Health and Nutrition Examination Survey, American Academy of Ophthalmology Preferred Practice Patterns, Medicare Payment Schedule. Study Design Cost-effectiveness Monte Carlo simulation. Data Collection/Extraction Methods Literature review, analysis of existing surveys. Principal Findings Biennial eye evaluation was the most cost-effective treatment option when the ability to detect other eye conditions was included in the model. Telemedicine was most cost-effective when other eye conditions were not considered or when telemedicine was assumed to detect refractive error. The current annual eye evaluation recommendation was costly compared with either treatment alternative. Self-referral was most cost-effective up to a willingness to pay (WTP) of U.S.$37,600, with either biennial or annual evaluation most cost-effective at higher WTP levels. Conclusions Annual eye evaluations are costly and add little benefit compared with either plausible alternative. More research on the ability of telemedicine to detect other eye conditions is needed to determine whether it is more cost-effective than biennial eye evaluation. PMID:21492158
Nel, Andre E.; Nasser, Elina; Godwin, Hilary; Avery, David; Bahadori, Tina; Bergeson, Lynn; Beryt, Elizabeth; Bonner, James C.; Boverhof, Darrell; Carter, Janet; Castranova, Vince; DeShazo, J. R.; Hussain, Saber M.; Kane, Agnes B.; Klaessig, Fred; Kuempel, Eileen; Lafranconi, Mark; Landsiedel, Robert; Malloy, Timothy; Miller, Mary Beth; Morris, Jeffery; Moss, Kenneth; Oberdorster, Gunter; Pinkerton, Kent; Pleus, Richard C.; Shatkin, Jo Anne; Thomas, Rusty; Tolaymat, Thabet; Wang, Amy; Wong, Jeffrey
2014-01-01
There has been a conceptual shift in toxicological studies from describing what happens to explaining how the adverse outcome occurs, thereby enabling a deeper and improved understanding of how biomolecular and mechanistic profiling can inform hazard identification and improve risk assessment. Compared to traditional toxicology methods, which have a heavy reliance on animals, new approaches to generate toxicological data are becoming available for the safety assessment of chemicals, including high-throughput and high-content screening (HTS, HCS). With the emergence of nanotechnology, the exponential increase in the total number of engineered nanomaterials (ENMs) in research, development, and commercialization requires a robust scientific approach to screen ENM safety in humans and the environment rapidly and efficiently. Spurred by the developments in chemical testing, a promising new toxicological paradigm for ENMs is to use alternative test strategies (ATS), which reduce reliance on animal testing through the use of in vitro and in silico methods such as HTS, HCS, and computational modeling. Furthermore, this allows for the comparative analysis of large numbers of ENMs simultaneously and for hazard assessment at various stages of the product development process and overall life cycle. Using carbon nanotubes as a case study, a workshop bringing together national and international leaders from government, industry, and academia was convened at the University of California, Los Angeles to discuss the utility of ATS for decision-making analyses of ENMs. After lively discussions, a short list of generally shared viewpoints on this topic was generated, including a general view that ATS approaches for ENMs can significantly benefit chemical safety analysis. PMID:23924032
Application of the ToxMiner Database: Network Analysis of ...
The US EPA ToxCast program is using in vitro HTS (High-Throughput Screening) methods to profile and model bioactivity of environmental chemicals. The main goals of the ToxCast program are to generate predictive signatures of toxicity, and ultimately provide rapid and cost-effective alternatives to animal testing. The chemicals selected for Phase I are composed largely by a diverse set of pesticide active ingredients, which had sufficient supporting in vivo data included as part of their registration process with the EPA. Other miscellaneous chemicals of environmental concern were also included. Application of HTS to environmental toxicants is a novel approach to predictive toxicology and health risk assessment, and differs from what is required for drug efficacy screening in that biochemical interaction of environmental chemicals are sometimes weaker than that seen with drugs and their intended targets. Additionally, the chemical space covered by environmental chemicals is much broader compared to that of pharmaceuticals. The ToxMiner database has been created and added to the EPA’s ACToR (Aggregated Computational Toxicology Resource) chemical database. One purpose of the ToxMiner database is to link biological, metabolic and cellular pathway data to genes and in vitro assay data for the initial subset of chemicals screened in the ToxCast Phase I HTS assays. Also included in ToxMiner is human disease information, which correlates with ToxCast assays that tar
Peng, Lan; Fan, Jialong; Tong, Chunyi; Xie, Zhenhua; Zhao, Chuan; Liu, Xuanming; Zhu, Yonghua; Liu, Bin
2016-09-15
Mung bean nuclease is a single stranded specific DNA and RNA endonuclease purified from mung bean sprouts. It yields 5'-phosphate terminated mono- and oligonucleotides. The activity level of this nuclease can act as a marker to monitor the developmental process of mung bean sprouts. In order to facilitate the activity and physiological analysis of this nuclease, we have developed a biosensing assay system based on the mung bean nuclease-induced single-stranded DNA scission and the affinity difference of graphene oxide for single-stranded DNA containing different numbers of bases. This end-point measurement method can detect mung bean nuclease in a range of 2×10(-4) to 4×10(-2) with a detection limit of 1×10(-4) unit/mL. In addition, we demonstrate the utility of the assay for screening chemical antibiotics and metal ions, resulting in the identification of several inhibitors of this enzyme in vitro. Furthermore, we firstly report that inhibiting mung bean nuclease by gentamycin sulfate and kanamycin in vivo can suppress mung bean sprouts growth. In summary, this method provides an alternative tool for the biochemical analysis for mung bean nuclease and indicates the feasibility of high-throughput screening specific inhibitors of this nuclease in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.
Application of the ToxMiner Database: Network Analysis ...
The US EPA ToxCast program is using in vitro HTS (High-Throughput Screening) methods to profile and model bioactivity of environmental chemicals. The main goals of the ToxCast program are to generate predictive signatures of toxicity, and ultimately provide rapid and cost-effective alternatives to animal testing. The chemicals selected for Phase I are composed largely by a diverse set of pesticide active ingredients, which had sufficient supporting in vivo data included as part of their registration process with the EPA. Other miscellaneous chemicals of environmental concern were also included. Application of HTS to environmental toxicants is a novel approach to predictive toxicology and health risk assessment, and differs from what is required for drug efficacy screening in that biochemical interaction of environmental chemicals are sometimes weaker than that seen with drugs and their intended targets. Additionally, the chemical space covered by environmental chemicals is much broader compared to that of pharmaceuticals. The ToxMiner database has been created and added to the EPA’s ACToR (Aggregated Computational Toxicology Resource) chemical database. One purpose of the ToxMiner database is to link biological, metabolic, and cellular pathway data to genes and in vitro assay data for the initial subset of chemicals screened in the ToxCast Phase I HTS assays. Also included in ToxMiner is human disease information, which correlates with ToxCast assays that ta
Survey of Older Drivers’ Experiences with Florida’s Mandatory Vision Re-Screening Law for Licensure
McGwin, Gerald; McCartt, Anne T.; Braitman, Keli A.; Owsley, Cynthia
2008-01-01
Purpose To document the license renewal experiences of Florida drivers ages 80 and older who must pass a visual acuity test when renewing their driver’s license. Participants A random sample of Florida residents ages 80 and older whose driver’s licenses were scheduled to expire between January 1, 2004 and June 30, 2005 as identified by the Florida Department of Highway Safety and Motor Vehicles. Methods Study participants (n=1,242 drivers) were contacted via telephone and completed a survey regarding their experiences with the license renewal process. Results The majority (80.2%) of those eligible for license renewal reportedly attempted to do so and 88.0% succeeded the first time they tried. A large percentage of drivers (88%) who failed the vision test said they sought treatment, and 77.6% of drivers who reattempted renewal reportedly passed the test. About half of drivers who did not seek renewal said they thought they would fail the vision test. The majority of those choosing not to renew their license (99.5%) reported using transportation alternatives. Conclusions This Study suggests that the Florida vision screening re-licensure law is not a deterrent to seeking license renewal for the ≥80-year-old population. Furthermore, only a small percentage of Florida drivers ages ≥ 80 years and older reported that they failed the visual acuity screening test and were denied license renewal. PMID:18432496
Nacheva, E P; Gribble, S; Andrews, K; Wienberg, J; Grace, C D
2000-10-15
We report the application of multi-color fluorescence in situ hydribidization (FISH) for bone marrow metaphase cell analysis of hematological malignancies using a sub-set of the human karyotype for chromosome painting. A combination of chromosome probes labeled with three haptens enabled the construction of a "painting probe" which detects seven different chromosomes. The probe was used to screen three chronic myeloid leukemia (CML) derived cell lines and ten CML patient bone marrow samples for aberrations, additional to the Ph rearrangement, that are associated with the onset of blast crisis of CML. This approach was shown to identify karyotype changes commonly seen by conventional karyotyping, and in addition revealed chromosome changes unresolved or undetected by conventional cytogenetic analysis. The seven-color painting probe provides a useful, fast, and reliable complementary tool for chromosome analysis, especially in cases with poor chromosome morphology. This is a simple approach, since the probes can be displayed in a standard red/green/blue format accessible to standard fluorescence microscopes and image-processing software. The proposed approach using panels of locus-specific probes as well as chromosome paints will be useful in all diagnostic routine environments where analysis is directed towards screening for genetic rearrangements and/or specific patterns of chromosome involvement with diagnostic/prognostic value.
Stadlmair, Lara F; Letzel, Thomas; Drewes, Jörg E; Grassmann, Johanna
2018-08-01
At present, the removal of trace organic chemicals such as pharmaceuticals in wastewater treatment plants is often incomplete resulting in a continuous discharge into the aqueous environment. To overcome this issue, bioremediation approaches gained significant importance in recent times, since they might have a lower carbon footprint than chemical or physical treatment methods. In this context, enzyme-based technologies represent a promising alternative since they are able to specifically target certain chemicals. For this purpose, versatile monitoring of enzymatic reactions is of great importance in order to understand underlying transformation mechanisms and estimate the suitability of various enzymes exhibiting different specificities for bioremediation purposes. This study provides a comprehensive review, summarizing research on enzymatic transformation of pharmaceuticals in water treatment applications using traditional and state-of-the-art enzyme screening approaches with a special focus on mass spectrometry (MS)-based and high-throughput tools. MS-based enzyme screening represents an approach that allows a comprehensive mechanistic understanding of enzymatic reactions and, in particular, the identification of transformation products. A critical discussion of these approaches for implementation in wastewater treatment processes is also presented. So far, there are still major gaps between laboratory- and field-scale research that need to be overcome in order to assess the viability for real applications. Copyright © 2018 Elsevier Ltd. All rights reserved.
Gravitational anti-screening as an alternative to dark matter
NASA Astrophysics Data System (ADS)
Penner, A. Raymond
2016-04-01
A semiclassical model of the screening of electric charge by virtual electric dipoles, as found in electrodynamic theory, will be presented. This model is then applied to the hypothetical case of an electric force where like charges attract. The resulting anti-screening of the electric charge is found to have the same functional dependence on the field source and observation distance that is found with the Baryonic Tully-Fisher Relationship. This leads to an anti-screening model for the gravitational force which is then used to determine the theoretical rotational curve of the Galaxy and the theoretical velocity dispersions and shear values for the Coma cluster. These theoretical results are found to be in good agreement with the corresponding astronomical observations. The screening of electric charge as found in QED and the larger apparent masses of galaxies and galactic clusters therefore appears to be two sides of the same coin.
Rotem, Asaf; Janzer, Andreas; Izar, Benjamin; Ji, Zhe; Doench, John G.; Garraway, Levi A.; Struhl, Kevin
2015-01-01
Colony formation in soft agar is the gold-standard assay for cellular transformation in vitro, but it is unsuited for high-throughput screening. Here, we describe an assay for cellular transformation that involves growth in low attachment (GILA) conditions and is strongly correlated with the soft-agar assay. Using GILA, we describe high-throughput screens for drugs and genes that selectively inhibit or increase transformation, but not proliferation. Such molecules are unlikely to be found through conventional drug screening, and they include kinase inhibitors and drugs for noncancer diseases. In addition to known oncogenes, the genetic screen identifies genes that contribute to cellular transformation. Lastly, we demonstrate the ability of Food and Drug Administration-approved noncancer drugs to selectively kill ovarian cancer cells derived from patients with chemotherapy-resistant disease, suggesting this approach may provide useful information for personalized cancer treatment. PMID:25902495
Rotem, Asaf; Janzer, Andreas; Izar, Benjamin; Ji, Zhe; Doench, John G; Garraway, Levi A; Struhl, Kevin
2015-05-05
Colony formation in soft agar is the gold-standard assay for cellular transformation in vitro, but it is unsuited for high-throughput screening. Here, we describe an assay for cellular transformation that involves growth in low attachment (GILA) conditions and is strongly correlated with the soft-agar assay. Using GILA, we describe high-throughput screens for drugs and genes that selectively inhibit or increase transformation, but not proliferation. Such molecules are unlikely to be found through conventional drug screening, and they include kinase inhibitors and drugs for noncancer diseases. In addition to known oncogenes, the genetic screen identifies genes that contribute to cellular transformation. Lastly, we demonstrate the ability of Food and Drug Administration-approved noncancer drugs to selectively kill ovarian cancer cells derived from patients with chemotherapy-resistant disease, suggesting this approach may provide useful information for personalized cancer treatment.
Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes
Titoiu, Ana Maria; Marty, Jean-Louis
2018-01-01
This review provides a brief overview of the fabrication and properties of screen-printed electrodes and details the different opportunities to apply them for the detection of antibiotics, detection of bacteria and antibiotic susceptibility. Among the alternative approaches to costly chromatographic or ELISA methods for antibiotics detection and to lengthy culture methods for bacteria detection, electrochemical biosensors based on screen-printed electrodes present some distinctive advantages. Chemical and (bio)sensors for the detection of antibiotics and assays coupling detection with screen-printed electrodes with immunomagnetic separation are described. With regards to detection of bacteria, the emphasis is placed on applications targeting viable bacterial cells. While the electrochemical sensors and biosensors face many challenges before replacing standard analysis methods, the potential of screen-printed electrodes is increasingly exploited and more applications are anticipated to advance towards commercial analytical tools. PMID:29562637
Risks of Liver (Hepatocellular) Cancer Screening
... rare, but serious, side effects : Hemorrhage . Trouble breathing. Leakage of bile , which can cause an infection of ... of the latest published information on cancer prevention, detection, genetics, treatment, supportive care, and complementary and alternative ...
[How can the cost of screening for toxoplasmosis during pregnancy be reduced?].
Ancelle, T; Yera, H; Talabani, H; Lebuisson, A; Thulliez, P; Dupouy-Camet, J
2009-12-01
A program of systematic serology screening for toxoplasmosis during pregnancy has been running in France since 1978. The program involves monthly follow-ups for all non-immune pregnant women. Due to the steady decline in the seroprevalence of toxoplasmosis, the cost of the program is steadily increasing. Current screening is based on the detection of IgG and IgM isotypes. The aim of this work was to estimate the benefit of replacing combined dosage of two isotypes, by an alternative strategy that detects total anti-Toxoplasma immunoglobulins. The rate of decreasing seroprevalence and the increasing burden on serological examinations was measured in a study population of pregnant women who were checked for toxoplasmosis by the parasitology laboratory of the Cochin Hospital, Paris. The increase in screening costs was estimated for the all-pregnant women and the expected benefits stemming from simply measuring total anti-Toxoplasma immunoglobulins compared to the double IgG-IgM assay were estimated. Between 1987 and 2008, the seroprevalence of toxoplasmosis measured at the Cochin hospital dropped from 70.8% to 48.6% with a 1.77% annual rate of decline. This downward trend is similar to that observed by the national perinatal surveys performed in 1995 and in 2003. As the number of non-immune women to follow-up each month is constantly increasing, the proportion of negative tests issued reached 87.6% in 2008. Extrapolating these results to the whole of France, we estimated that the number of required screening tests perform was increasing by 93,000 units per year with an additional associated cost of one million euros. Various alternative scenarios of antibody detection are proposed that could save between 40.2% and 48.4% of current screening costs. Replacement of combined dosage of IgG and IgM isotypes by determination of just total Ig would significantly reduce costs of toxoplasmosis screening for pregnant women, without effecting either the general strategy, or proven efficiency of the national program.
Fake facts and alternative truths in medical research.
Hofmann, Bjørn
2018-01-27
Fake news and alternative facts have become commonplace in these so-called "post-factual times." What about medical research - are scientific facts fake as well? Many recent disclosures have fueled the claim that scientific facts are suspect and that science is in crisis. Scientists appear to engage in facting interests instead of revealing interesting facts. This can be observed in terms of what has been called polarised research, where some researchers continuously publish positive results while others publish negative results on the same issue - even when based on the same data. In order to identify and address this challenge, the objective of this study is to investigate how polarised research produce "polarised facts." Mammography screening for breast cancer is applied as an example. The main benefit with mammography screening is the reduced breast cancer mortality, while the main harm is overdiagnosis and subsequent overtreatment. Accordingly, the Overdiagnosis to Mortality Reduction Ratio (OMRR) is an estimate of the risk-benefit-ratio for mammography screening. As there are intense interests involved as well as strong opinions in debates on mammography screening, one could expect polarisation in published results on OMRR. A literature search identifies 8 studies publishing results for OMRR and reveals that OMRR varies 25-fold, from 0.4 to 10. Two experts in polarised research were asked to rank the attitudes of the corresponding authors to mammography screening of the identified publications. The results show a strong correlation between the OMRR and the authors' attitudes to screening (R = 0.9). Mammography screening for breast cancer appears as an exemplary field of strongly polarised research. This is but one example of how scientists' strong professional interests can polarise research. Instead of revealing interesting facts researchers may come to fact interests. In order to avoid this and sustain trust in science, researchers should disclose professional and not only financial interests when submitting and publishing research.
Implementing a method of screening one-well hydraulic barrier design alternatives.
Rubin, Hillel; Shoemaker, Christine A; Köngeter, Jürgen
2009-01-01
This article provides details of applying the method developed by the authors (Rubin et al. 2008b) for screening one-well hydraulic barrier design alternatives. The present article with its supporting information (manual and electronic spreadsheets with a case history example) provides the reader complete details and examples of solving the set of nonlinear equations developed by Rubin et al. (2008b). It allows proper use of the analytical solutions and also depicting the various charts given by Rubin et al. (2008b). The final outputs of the calculations are the required position and the discharge of the pumping well. If the contaminant source is nonaqueous phase liquid (NAPL) entrapped within the aquifer, then the method provides an estimate of the aquifer remediation progress (which is a by-product) due to operating the hydraulic barrier.
Region-to-area screening methodology for the Crystalline Repository Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1985-04-01
The purpose of this document is to describe the Crystalline Repository Project's (CRP) process for region-to-area screening of exposed and near-surface crystalline rock bodies in the three regions of the conterminous United States where crystalline rock is being evaluated as a potential host for the second nuclear waste repository (i.e., in the North Central, Northeastern, and Southeastern Regions). This document indicates how the US Department of Energy's (DOE) General Guidelines for the Recommendation of Sites for Nuclear Waste Repositories (10 CFR 960) were used to select and apply factors and variables for the region-to-area screening, explains how these factors andmore » variable are to be applied in the region-to-area screening, and indicates how this methodology relates to the decision process leading to the selection of candidate areas. A brief general discussion of the screening process from the national survey through area screening and site recommendation is presented. This discussion sets the scene for detailed discussions which follow concerning the region-to-area screening process, the guidance provided by the DOE Siting Guidelines for establishing disqualifying factors and variables for screening, and application of the disqualifying factors and variables in the screening process. This document is complementary to the regional geologic and environmental characterization reports to be issued in the summer of 1985 as final documents. These reports will contain the geologic and environmental data base that will be used in conjunction with the methodology to conduct region-to-area screening.« less
[Cost-effectiveness analysis of universal screening for thyroid disease in pregnant women in Spain].
Donnay Candil, Sergio; Balsa Barro, José Antonio; Álvarez Hernández, Julia; Crespo Palomo, Carlos; Pérez-Alcántara, Ferrán; Polanco Sánchez, Carlos
2015-01-01
To assess the cost-effectiveness of universal screening for thyroid disease in pregnant women in Spain as compared to high risk screening and no screening. A decision-analytic model comparing the incremental cost per quality-adjusted life year (QALY) of universal screening versus high risk screening and versus no screening. was used for the pregnancy and postpartum period. Probabilities from randomized controlled trials were considered for adverse obstetrical outcomes. A Markov model was used to assess the lifetime period after the first postpartum year and account for development of overt hypothyroidism. The main assumptions in the model and use of resources were assessed by local clinical experts. The analysis considered direct healthcare costs only. Universal screening gained .011 QALYs over high risk screening and .014 QALYS over no screening. Total direct costs per patient were €5,786 for universal screening, €5,791 for high risk screening, and €5,781 for no screening. Universal screening was dominant compared to risk-based screening and a very cost-effective alternative as compared to no screening. Use of universal screening instead of high risk screening would result in €2,653,854 annual savings for the Spanish National Health System. Universal screening for thyroid disease in pregnant women in the first trimester is dominant in Spain as compared to risk-based screening, and is cost-effective as compared to no screening (incremental cost-effectiveness ratio of €374 per QALY). Moreover, it allows diagnosing and treating cases of clinical and subclinical hypothyroidism that may not be detected when only high-risk women are screened. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
Siedlikowski, Sophia; Ells, Carolyn; Bartlett, Gillian
2018-01-01
A decision to undertake screening for breast cancer often takes place within the primary care setting, but current controversies such as overdiagnosis and inconsistent screening recommendations based on evolving evidence render this a challenging process, particularly for average-risk women. Given the responsibility of primary care providers in counseling women in this decision-making process, it is important to understand their thoughts on these controversies and how they manage uncertainty in their practice. To review the perspectives and approaches of primary care providers regarding mammography decision-making with average-risk women. This study is a critical interpretive review of peer-review literature that reports primary care provider perspectives on mammography screening decision-making. Ovid MEDLINE®, Ovid PsycInfo, and Scopus databases were searched with dates from 2002 to 2017 using search terms related to mammography screening, uncertainty, counseling, decision-making, and primary health care providers. Nine articles were included following a review process involving the three authors. Using an inductive and iterative approach, data were grouped into four thematic categories: (1) perceptions on the effectiveness of screening, screening initiation age, and screening frequency; (2) factors guiding primary care providers in the screening decision-making process, including both provider and patient-related factors, (3) uncertainty faced by primary care providers regarding guidelines and screening discussions with their patients; and (4) informed decision-making with average-risk women, including factors that facilitate and hinder this process. The discussion of results addresses several factors about the diversity of perspectives and practices of physicians counseling average-risk women regarding breast cancer screening. This has implications for the challenge of understanding and explaining evidence, what should be shared with average-risk women considering screening, the forms of knowledge that physicians value to guide screening decision-making, and the consent process for population-based screening initiatives. Within the data, there was little attention placed on how physicians coped with uncertainty in practice. Given the dual responsibility of physicians in caring for both individuals and the larger population, further research should probe more deeply into how they balance their duties to individual patients with those to the larger population they serve.
Tufail, Adnan; Kapetanakis, Venediktos V; Salas-Vega, Sebastian; Egan, Catherine; Rudisill, Caroline; Owen, Christopher G; Lee, Aaron; Louw, Vern; Anderson, John; Liew, Gerald; Bolter, Louis; Bailey, Clare; Sadda, SriniVas; Taylor, Paul; Rudnicka, Alicja R
2016-12-01
Diabetic retinopathy screening in England involves labour-intensive manual grading of retinal images. Automated retinal image analysis systems (ARIASs) may offer an alternative to manual grading. To determine the screening performance and cost-effectiveness of ARIASs to replace level 1 human graders or pre-screen with ARIASs in the NHS diabetic eye screening programme (DESP). To examine technical issues associated with implementation. Observational retrospective measurement comparison study with a real-time evaluation of technical issues and a decision-analytic model to evaluate cost-effectiveness. A NHS DESP. Consecutive diabetic patients who attended a routine annual NHS DESP visit. Retinal images were manually graded and processed by three ARIASs: iGradingM (version 1.1; originally Medalytix Group Ltd, Manchester, UK, but purchased by Digital Healthcare, Cambridge, UK, at the initiation of the study, purchased in turn by EMIS Health, Leeds, UK, after conclusion of the study), Retmarker (version 0.8.2, Retmarker Ltd, Coimbra, Portugal) and EyeArt (Eyenuk Inc., Woodland Hills, CA, USA). The final manual grade was used as the reference standard. Arbitration on a subset of discrepancies between manual grading and the use of an ARIAS by a reading centre masked to all grading was used to create a reference standard manual grade modified by arbitration. Screening performance (sensitivity, specificity, false-positive rate and likelihood ratios) and diagnostic accuracy [95% confidence intervals (CIs)] of ARIASs. A secondary analysis explored the influence of camera type and patients' ethnicity, age and sex on screening performance. Economic analysis estimated the cost per appropriate screening outcome identified. A total of 20,258 patients with 102,856 images were entered into the study. The sensitivity point estimates of the ARIASs were as follows: EyeArt 94.7% (95% CI 94.2% to 95.2%) for any retinopathy, 93.8% (95% CI 92.9% to 94.6%) for referable retinopathy and 99.6% (95% CI 97.0% to 99.9%) for proliferative retinopathy; and Retmarker 73.0% (95% CI 72.0% to 74.0%) for any retinopathy, 85.0% (95% CI 83.6% to 86.2%) for referable retinopathy and 97.9% (95% CI 94.9 to 99.1%) for proliferative retinopathy. iGradingM classified all images as either 'disease' or 'ungradable', limiting further iGradingM analysis. The sensitivity and false-positive rates for EyeArt were not affected by ethnicity, sex or camera type but sensitivity declined marginally with increasing patient age. The screening performance of Retmarker appeared to vary with patient's age, ethnicity and camera type. Both EyeArt and Retmarker were cost saving relative to manual grading either as a replacement for level 1 human grading or used prior to level 1 human grading, although the latter was less cost-effective. A threshold analysis testing the highest ARIAS cost per patient before which ARIASs became more expensive per appropriate outcome than human grading, when used to replace level 1 grader, was Retmarker £3.82 and EyeArt £2.71 per patient. The non-randomised study design limited the health economic analysis but the same retinal images were processed by all ARIASs in this measurement comparison study. Retmarker and EyeArt achieved acceptable sensitivity for referable retinopathy and false-positive rates (compared with human graders as reference standard) and appear to be cost-effective alternatives to a purely manual grading approach. Future work is required to develop technical specifications to optimise deployment and address potential governance issues. The National Institute for Health Research (NIHR) Health Technology Assessment programme, a Fight for Sight Grant (Hirsch grant award) and the Department of Health's NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital and the University College London Institute of Ophthalmology.
Bergsdorf, Christian; Fiez-Vandal, Cédric; Sykes, David A; Bernet, Pascal; Aussenac, Sonia; Charlton, Steven J; Schopfer, Ulrich; Ottl, Johannes; Duckely, Myriam
2016-03-01
Integral membrane proteins (IMPs) play an important role in many cellular events and are involved in numerous pathological processes. Therefore, understanding the structure and function of IMPs is a crucial prerequisite to enable successful targeting of these proteins with low molecular weight (LMW) ligands early on in the discovery process. To optimize IMP purification/crystallization and to identify/characterize LMW ligand-target interactions, robust, reliable, high-throughput, and sensitive biophysical methods are needed. Here, we describe a differential scanning fluorimetry (DSF) screening method using the thiol-reactive BODIPY FL-cystine dye to monitor thermal unfolding of the G-protein-coupled receptor (GPCR), CXCR2. To validate this method, the seven-transmembrane protein CXCR2 was analyzed with a set of well-characterized antagonists. This study showed that the new DSF assay assessed reliably the stability of CXCR2 in a 384-well format. The analysis of 14 ligands with a potency range over 4 log units demonstrated the detection/characterization of LMW ligands binding to the membrane protein target. Furthermore, DSF results cross-validated with the label-free differential static light scattering (DSLS) thermal denaturation method. These results underline the potential of the BODIPY assay format as a general tool to investigate membrane proteins and their interaction partners. © 2015 Society for Laboratory Automation and Screening.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marmer, G.J.; Dunn, C.P.; Moeller, K.L.
Uranium enrichment in the United States has utilized a diffusion process to preferentially enrich the U-235 isotope in the uranium product. The U-AVLIS process is based on electrostatic extraction of photoionized U-235 atoms from an atomic vapor stream created by electron-beam vaporization of uranium metal alloy. The U-235 atoms are ionized when precisely tuned laser light -- of appropriate power, spectral, and temporal characteristics -- illuminates the uranium vapor and selectively photoionizes the U-235 isotope. A programmatic document for use in screening DOE site to locate a U-AVLIS production plant was developed and implemented in two parts. The first partmore » consisted of a series of screening analyses, based on exclusionary and other criteria, that identified a reasonable number of candidate sites. These sites were subjected to a more rigorous and detailed comparative analysis for the purpose of developing a short list of reasonable alternative sites for later environmental examination. This environmental site description (ESD) provides a detailed description of the PGDP site and vicinity suitable for use in an environmental impact statement (EIS). The report is based on existing literature, data collected at the site, and information collected by Argonne National Laboratory (ANL) staff during a site visit. 65 refs., 15 tabs.« less
DNA-Compatible Nitro Reduction and Synthesis of Benzimidazoles.
Du, Huang-Chi; Huang, Hongbing
2017-10-18
DNA-encoded chemical libraries have emerged as a cost-effective alternative to high-throughput screening (HTS) for hit identification in drug discovery. A key factor for productive DNA-encoded libraries is the chemical diversity of the small molecule moiety attached to an encoding DNA oligomer. The library structure diversity is often limited to DNA-compatible chemical reactions in aqueous media. Herein, we describe a facile process for reducing aryl nitro groups to aryl amines. The new protocol offers simple operation and circumvents the pyrophoric potential of the conventional method (Raney nickel). The reaction is performed in aqueous solution and does not compromise DNA structural integrity. The utility of this method is demonstrated by the versatile synthesis of benzimidazoles on DNA.
High throughput screening of active pharmaceutical ingredients by UPLC.
Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun
2008-07-01
Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.
Evaluation of the Occupational Risks from Jet Fuel (Toxicity Screening Battery)
2012-09-01
1α may serve as a marker of epidermal damage or stress due to irritation in this in vitro model. As an alternative to the 3-dimensional human skin...AFRL-RH-FS-SR-2013-0003 Final Report: Evaluation of the Occupational Risks from Jet Fuel (Toxicity Screening Battery) David R. Mattie...2. REPORT TYPE Special Report 3. DATES COVERED (From - To) Oct 2010 – Dec 2011 4. TITLE AND SUBTITLE Evaluation of the Occupational Risks from
Lin, Sung-Yao; Sun, Xing-Han; Hsiao, Yu-Hsuan; Chang, Shao-En; Li, Guan-Syun; Hu, Nien-Jen
2016-01-01
Membrane proteins play key roles in many fundamental functions in cells including ATP synthesis, ion and molecule transporter, cell signalling and enzymatic reactions, accounting for ~30% genes of whole genomes. However, the hydrophobic nature of membrane proteins frequently hampers the progress of structure determination. Detergent screening is the critical step in obtaining stable detergent-solubilized membrane proteins and well-diffracting protein crystals. Fluorescence Detection Size Exclusion Chromatography (FSEC) has been developed to monitor the extraction efficiency and monodispersity of membrane proteins in detergent micelles. By tracing the FSEC profiles of GFP-fused membrane proteins, this method significantly enhances the throughput of detergent screening. However, current methods to acquire FSEC profiles require either an in-line fluorescence detector with the SEC equipment or an off-line spectrofluorometer microplate reader. Here, we introduce an alternative method detecting the absorption of GFP (FA-SEC) at 485 nm, thus making this methodology possible on conventional SEC equipment through the in-line absorbance spectrometer. The results demonstrate that absorption is in great correlation with fluorescence of GFP. The comparably weaker absorption signal can be improved by using a longer path-length flow cell. The FA-SEC profiles were congruent with the ones plotted by FSEC, suggesting FA-SEC could be a comparable and economical setup for detergent screening of membrane proteins.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DADO MA
2008-07-31
This study focuses on the remediation methods and technologies applicable for use at 200-PO-I Groundwater Operable Unit (OU) at the Hanford Site. The 200-PO-I Groundwater au requires groundwater remediation because of the existence of contaminants of potential concern (COPC). A screening was conducted on alternative technologies and methods of remediation to determine which show the most potential for remediation of groundwater contaminants. The possible technologies were screened to determine which would be suggested for further study and which were not applicable for groundwater remediation. COPCs determined by the Hanford Site groundwater monitoring were grouped into categories based on properties linkingmore » them by remediation methods applicable to each COPC group. The screening considered the following criteria. (1) Determine if the suggested method or technology can be used for the specific contaminants found in groundwater and if the technology can be applied at the 200-PO-I Groundwater au, based on physical characteristics such as geology and depth to groundwater. (2) Evaluate screened technologies based on testing and development stages, effectiveness, implementability, cost, and time. This report documents the results of an intern research project conducted by Mathew Dado for Central Plateau Remediation in the Soil and Groundwater Remediation Project. The study was conducted under the technical supervision of Gloria Cummins and management supervision of Theresa Bergman and Becky Austin.« less
Lorvidhaya, Peem; Mendoza, Ivan; Sehli, Sharmila; Atalay, Michael K; Kim, Michael H
2013-11-01
Lead insulation defects with externalization of the conductors exist in Riata defibrillator leads. Cinefluoroscopy is currently the gold standard to detect such defects. Prospective evaluation of alternative screening options such as chest radiography (CXR), which has been recommended by the FDA, is not well described. Patients with Riata leads underwent cinefluoroscopy, CXR, and device interrogation. Leads were classified as abnormal (clear cable separation), borderline, or normal by independent evaluation of cinefluoroscopy and CXR. CXR evaluation was done in two ways as follows: (1) routine CXR read by daily staff radiologists for lead screening and (2) CXR evaluation by a radiologist educated about the lead defect. One hundred two patients were evaluated at our institution. Cinefluoroscopy showed externalized conductors in 33 patients (32 %). Twenty-five of 33 patients (76 %) who had abnormal cinefluoroscopic findings had abnormal CXR findings on blinded review by the educated radiologist. All 25 patients with abnormal CXR had abnormal findings on cinefluoroscopy. Daily staff radiologists without direct education other than prompts for lead screening detected CXR abnormalities in only 8 out of 102 (8 %) cases. Cinefluoroscopy appears to be more sensitive than CXR for the detection of Riata cable extrusion. Interpretation of CXR by a radiologist with education in lead defects correlates highly with cinefluoroscopy with very high specificity. Depending on available resources for screening, CXR may be a reasonable alternative to cinefluoroscopy. Multidisciplinary collaboration across specialties (radiology and electrophysiology) can lead to improved diagnostic capability and thus the potential for enhanced quality of care.
Valuing Equal Protection in Aviation Security Screening.
Nguyen, Kenneth D; Rosoff, Heather; John, Richard S
2017-12-01
The growing number of anti-terrorism policies has elevated public concerns about discrimination. Within the context of airport security screening, the current study examines how American travelers value the principle of equal protection by quantifying the "equity premium" that they are willing to sacrifice to avoid screening procedures that result in differential treatments. In addition, we applied the notion of procedural justice to explore the effect of alternative selective screening procedures on the value of equal protection. Two-hundred and twenty-two respondents were randomly assigned to one of three selective screening procedures: (1) randomly, (2) using behavioral indicators, or (3) based on demographic characteristics. They were asked to choose between airlines using either an equal or a discriminatory screening procedure. While the former requires all passengers to be screened in the same manner, the latter mandates all passengers undergo a quick primary screening and, in addition, some passengers are selected for a secondary screening based on a predetermined selection criterion. Equity premiums were quantified in terms of monetary cost, wait time, convenience, and safety compromise. Results show that equity premiums varied greatly across respondents, with many indicating little willingness to sacrifice to avoid inequitable screening, and a smaller minority willing to sacrifice anything to avoid the discriminatory screening. The selective screening manipulation was effective in that equity premiums were greater under selection by demographic characteristics compared to the other two procedures. © 2017 Society for Risk Analysis.
The Use of AlphaScreen Technology in HTS: Current Status
Eglen, Richard M; Reisine, Terry; Roby, Philippe; Rouleau, Nathalie; Illy, Chantal; Bossé, Roger; Bielefeld, Martina
2008-01-01
AlphaScreen (Amplified Luminescent Proximity Homogeneous Assay Screen) is versatile assay technology developed to measuring analytes using a homogenous protocol. This technology is an example of a bead-based proximity assay and was developed from a diagnostic assay technology known as LOCI (Luminescent Oxygen Channeling Assay). Here, singlet oxygen molecules, generated by high energy irradiation of Donor beads, travel over a constrained distance (approx. 200 nm) to Acceptor beads. This results in excitation of a cascading series of chemical reactions, ultimately causing generation of a chemiluminescent signal. In the past decade, a wide variety of applications has been reported, ranging from detection of analytes involved in cell signaling, including protein:protein, protein:peptide, protein:small molecule or peptide:peptide interactions. Numerous homogeneous HTS-optimized assays have been reported using the approach, including generation of second messengers (such as accumulation of cyclic AMP, cyclic GMP, inositol [1, 4, 5] trisphosphate or phosphorylated ERK) from liganded GPCRs or tyrosine kinase receptors, post-translational modification of proteins (such as proteolytic cleavage, phosphorylation, ubiquination and sumoylation) as well as protein-protein and protein-nucleic acid interactions. Recently, the basic AlphaScreen technology was extended in that the chemistry of the Acceptor bead was modified such that emitted light is more intense and spectrally defined, thereby markedly reducing interference from biological fluid matrices (such as trace hemolysis in serum and plasma). In this format, referred to as AlphaLISA, it provides an alternative technology to classical ELISA assays and is suitable for high throughput automated fluid dispensing and detection systems. Collectively, AlphaScreen and AlphaLISA technologies provide a facile assay platform with which one can quantitate complex cellular processes using simple no-wash microtiter plate based assays. They provide the means by which large compound libraries can be screened in a high throughput fashion at a diverse range of therapeutically important targets, often not readily undertaken using other homogeneous assay technologies. This review assesses the current status of the technology in drug discovery, in general, and high throughput screening (HTS), in particular. PMID:20161822
Martin, Michael S; Wells, George A; Crocker, Anne G; Potter, Beth K; Colman, Ian
2018-03-01
There is an increasing debate about the impact of mental health screening. We illustrate the use of a decision making framework that can be applied when there is no sufficient data to support a traditional cost-benefit analysis. We conducted secondary analyses of data from 459 male prisoners who were screened upon intake. We compared the potential benefit of different approaches (screening, history taking, and universal interventions) to allocating treatment resources using decision curve analysis. Screening prisoners for distress at typical levels of sensitivity (75%) and specificity (71%) were estimated to provide the greatest net benefit if between 2 and 5 false positives per detected illness are tolerable. History taking and self-harm screening provide the largest net benefit when only 1 or 2 false positives per detected illness would be tolerable. The benefits of screening were less among those without a recent psychiatric history, ethnic minorities, and those with fewer psychosocial needs. Although screening has potential to increase detection of treatment, important subgroup differences exist. Greater consideration of responses to positive screens or alternatives to screening are needed to maximize the impact of efforts to improve detection and treatment of mental illness. Copyright © 2017 John Wiley & Sons, Ltd.
24 CFR 3288.110 - Alternative Process agreements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Alternative Process agreements... HOUSING AND URBAN DEVELOPMENT MANUFACTURED HOME DISPUTE RESOLUTION PROGRAM Alternative Process in HUD-Administered States § 3288.110 Alternative Process agreements. (a) Required agreement. To use the Alternative...
Athletic Trainers' Attitudes Toward Drug Screening of Intercollegiate Athletes
Starkey, Chad; Abdenour, Thomas E.; Finnane, David
1994-01-01
Since the inception of NCAA-mandated drug screening in 1986, college athletic trainers have found themselves involved at various levels in institutional drug-screening programs. Several legal, moral, and ethical questions have been raised regarding the drug screening of college athletes, and studies have been conducted to rate athletes' attitudes toward this practice. We examined the responses of certified athletic trainers employed in college settings to ascertain their attitudes toward the drug screening of athletes in general, and, specifically, how they view their role in this process. Surveys were distributed to 500 college athletic trainers randomly selected from the membership database maintained by the National Athletic Trainers' Association, Inc (Dallas, TX). The results of this survey indicate that the majority of athletic trainers feel that their association with the drug-screening process places them in the dual role of police and counselor, but that this relationship does not negatively affect their rapport with their athletes. Opinions regarding the drug-screening process and the importance of education in deterring drug use are somewhat dependent upon the athletic trainer's involvement in the drug-screening process. Athletic trainers possess a stronger desire to serve as resource persons who organize substance abuse education programs rather than serving as administrators of the sampling process. PMID:16558274
Joint Test Report For Validation of Alternatives to Aliphatic Isocyanate Polyurethanes
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2007-01-01
National Aeronautics and Space Administration (NASA) and Air Force Space Command (AFSPC) have similar missions and therefore similar facilities and structures in similar environments. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. The most common topcoats used in coating systems are polyurethanes that contain isocyanates. Isocyanates are classified as potential human carcinogens and are known to cause cancer in animals. The primary objective of this effort was to demonstrate and validate alternatives to aliphatic isocyanate polyurethanes resulting in one or more isocyanate-free coatings qualified for use at AFSPC and NASA installations participating in this project. This joint Test Report (JTR) documents the results of the laboratory and field testing as well as any test modifications made during the execution of the testing. The technical stakeholders agreed upon test procedure modifications documented in this document. This JTR is made available as a reference for future pollution prevention endeavors by other NASA centers, the Department of Defense and commercial users to minimize duplication of effort. All coating system candidates were tested using approved NASA and AFSPC standard coating systems as experimental controls. This study looked at eight alternative coating systems and two control coating systems and was divided into Phase I Screening Tests, Phase II Tests, and Field Testing. The Phase I Screening Tests were preliminary tests performed on all the selected candidate coating systems. Candidate coating systems that did not meet the acceptance criteria of the screening tests were eliminated from further testing. Phase I Screening Tests included: Ease of Application, Surface Appearance, Dry-To-Touch (Sanding), Accelerated Storage Stability, Pot Life (Viscosity), Cure Time (Solvent Rubs), Cleanability, Knife Test, Tensile (pull-off) Adhesion, and X-Cut Adhesion by Wet Tape After a review of the Phase I test results, four of the alternative coating systems showed substandard performance in relation to the Control Systems and were eliminated from the Phase II testing. Due to the interest of stakeholders and time constraints, however, all eight alternatives were subjected to the following Phase II tests, along with field testing at Stennis Space Center (SSC), Mississippi: Hypergol Compatibility, Liquid Oxygen Compatibility, 18-Month Marine Exposure (Gloss Retention, Color Retention, Blistering, Visual Corrosion, Creepage from Scribe, Heat Adhesion), and Field Exposure (6- and 12-month Evaluation for Coating Condition, Color Retention, Gloss Retention). The remaining four alternative coating systems determined to be the best viable alternatives were carried on to Phase II testing that included: Removability, Repairability, Abrasion Resistance, Gravelometer, Fungus Resistance, Accelerated Weathering, Mandrel Bend Flexibility, and Cyclic Corrosion Resistance. Of the systems that continued to Phase II, three (3) alternative coating systems meet the performance requirements as identified by stakeholders. Two (2) other systems, that were not included in Phase II testing, performed well enough on the 18-Month Marine Exposure, the primary requirement for NASA technical standard NASA-STD-5008, Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment, that they were also considered to be successful candidates. In total, five (5) alternative coating systems were approved for inclusion in the NASA-STD- 5008 Qualified Products List (QPL). The standard is intended to provide a common framework for consistent practices across NASA and is often used by other entities. The standard's QPL does not connote endorsement of the products by NASA, but lists those products that have been tested and meet the requirements as specified.
The poly(A)-binding protein nuclear 1 suppresses alternative cleavage and polyadenylation sites.
Jenal, Mathias; Elkon, Ran; Loayza-Puch, Fabricio; van Haaften, Gijs; Kühn, Uwe; Menzies, Fiona M; Oude Vrielink, Joachim A F; Bos, Arnold J; Drost, Jarno; Rooijers, Koos; Rubinsztein, David C; Agami, Reuven
2012-04-27
Alternative cleavage and polyadenylation (APA) is emerging as an important layer of gene regulation. Factors controlling APA are largely unknown. We developed a reporter-based RNAi screen for APA and identified PABPN1 as a regulator of this process. Genome-wide analysis of APA in human cells showed that loss of PABPN1 resulted in extensive 3' untranslated region shortening. Messenger RNA transcription, stability analyses, and in vitro cleavage assays indicated enhanced usage of proximal cleavage sites (CSs) as the underlying mechanism. Using Cyclin D1 as a test case, we demonstrated that enhanced usage of proximal CSs compromises microRNA-mediated repression. Triplet-repeat expansion in PABPN1 (trePABPN1) causes autosomal-dominant oculopharyngeal muscular dystrophy (OPMD). The expression of trePABPN1 in both a mouse model of OPMD and human cells elicited broad induction of proximal CS usage, linked to binding to endogenous PABPN1 and its sequestration in nuclear aggregates. Our results elucidate a novel function for PABPN1 as a suppressor of APA. Copyright © 2012 Elsevier Inc. All rights reserved.
2013-01-01
Background Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. Methods A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55–74 years, and (c) biennial faecal immunochemical tests (FIT) at 55–74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55–64 years) and staggered age-based roll-out across the 55–74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55–74). Results FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381–1,053 with FSIG-based, and 967–1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. Conclusions While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning. PMID:23510135
Depression screening optimization in an academic rural setting.
Aleem, Sohaib; Torrey, William C; Duncan, Mathew S; Hort, Shoshana J; Mecchella, John N
2015-01-01
Primary care plays a critical role in screening and management of depression. The purpose of this paper is to focus on leveraging the electronic health record (EHR) as well as work flow redesign to improve the efficiency and reliability of the process of depression screening in two adult primary care clinics of a rural academic institution in USA. The authors utilized various process improvement tools from lean six sigma methodology including project charter, swim lane process maps, critical to quality tree, process control charts, fishbone diagrams, frequency impact matrix, mistake proofing and monitoring plan in Define-Measure-Analyze-Improve-Control format. Interventions included change in depression screening tool, optimization of data entry in EHR. EHR data entry optimization; follow up of positive screen, staff training and EHR redesign. Depression screening rate for office-based primary care visits improved from 17.0 percent at baseline to 75.9 percent in the post-intervention control phase (p<0.001). Follow up of positive depression screen with Patient History Questionnaire-9 data collection remained above 90 percent. Duplication of depression screening increased from 0.6 percent initially to 11.7 percent and then decreased to 4.7 percent after optimization of data entry by patients and flow staff. Impact of interventions on clinical outcomes could not be evaluated. Successful implementation, sustainability and revision of a process improvement initiative to facilitate screening, follow up and management of depression in primary care requires accounting for voice of the process (performance metrics), system limitations and voice of the customer (staff and patients) to overcome various system, customer and human resource constraints.
NASA Astrophysics Data System (ADS)
Pierce, S. A.; Figueroa B, E.
2016-12-01
Sound science and adequate models of systems are necessary for environmental decisions, yet frequently it is insufficient. This study documents the outcome of a co-design effort that was convened initially to explore the potential role that technology may have in supporting multi-stakeholder deliberation about sustainability transitions for a region. The project aims to create science-based deliberation among diverse stakeholders about water-energy-mineral use and choices in the Atacama Desert region of Chile. An interactive dashboard that pairs stakeholder preferences, concept maps with natural resource valuation models seeks to visualize useful information. The ultimate goal is to improve levels of understanding and open possibilities for collaborative problem solving by engaging industry, academics, and indigenous communities in a long- term participatory modeling process. Collaborative discussions build technical knowledge and bridge across sectors that are often at odds over management of earth resources. The project began in the shadow of marked conflict and tensions among participants. Methodologically, tensions have been reduced by combining social process with information delivery that leverages interactive touch screen applications. Models and information act as boundary objects among participants and the tenets of a conflict resolution process called sustained dialogue provide guidance for facilitating the group sessions. Early results indicate that the gesture-enabled touch screens are useful for establishing an accessible environment for deliberation because subject matter experts and laypeople can interact with information with equal ease. Social process has been critical for bridging scales, managing group expectations and relationships, and addressing differences in epistemological and cultural perspectives. Recent incorporation of economic and resource valuation highlights new aspects and alternative views of tradeoffs and potential impacts.
Vicente, Tiago; Mota, José P B; Peixoto, Cristina; Alves, Paula M; Carrondo, Manuel J T
2011-01-01
The advent of advanced therapies in the pharmaceutical industry has moved the spotlight into virus-like particles and viral vectors produced in cell culture holding great promise in a myriad of clinical targets, including cancer prophylaxis and treatment. Even though a couple of cases have reached the clinic, these products have yet to overcome a number of biological and technological challenges before broad utilization. Concerning the manufacturing processes, there is significant research focusing on the optimization of current cell culture systems and, more recently, on developing scalable downstream processes to generate material for pre-clinical and clinical trials. We review the current options for downstream processing of these complex biopharmaceuticals and underline current advances on knowledge-based toolboxes proposed for rational optimization of their processing. Rational tools developed to increase the yet scarce knowledge on the purification processes of complex biologicals are discussed as alternative to empirical, "black-boxed" based strategies classically used for process development. Innovative methodologies based on surface plasmon resonance, dynamic light scattering, scale-down high-throughput screening and mathematical modeling for supporting ion-exchange chromatography show great potential for a more efficient and cost-effective process design, optimization and equipment prototyping. Copyright © 2011 Elsevier Inc. All rights reserved.
Revolutionizing Toxicity Testing For Predicting Developmental Outcomes (DNT4)
Characterizing risk from environmental chemical exposure currently requires extensive animal testing; however, alternative approaches are being researched to increase throughput of chemicals screened, decrease reliance on animal testing, and improve accuracy in predicting adverse...
Media formulation influences chemical effects on neuronal growth and morphology
Abstract Screening for developmental neurotoxicity (DNT) using in vitro, cell-based test systems has been proposed as an efficient and cost-effective alternative to performing in vivo DNT studies. One of the pri...
Meeting Materials for the November 28-29, 2017 Scientific Advisory Panel
Meeting Materials for the November 28-30, 2017 Scientific Advisory Panel on Continuing Development of Alternative High-Throughput Screens to Determine Endocrine Disruption, Focusing on Androgen Receptor, Steroidogenesis, and Thyroid Pathways.
NASA Technical Reports Server (NTRS)
Powers. W. Edward
2010-01-01
This viewgraph presentation reviews the medical screening process and spacecraft launch and landing mission activities for astronauts. The topics include: 1) Launch and Landing Mission Overview; 2) Available Resources; and 3) Medical Screening Process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, Teresa; Graeff-Honninger, Simone; French, William Todd
The production of biodiesel has notably increased over the past decade. Currently, plant oil is the main feedstock for biodiesel production, but, due to concerns related to the competition with food production, alternative oil feedstocks have to be found. Oleaginous yeasts are known to produce high amounts of lipids, but no integrated process from microbial fermentation to final biodiesel production has reached commercial realization yet due to economic constraints. Therefore, growth and lipid production of red yeast Rhodotorula glutinis was tested on low-cost substrates, namely, wastewaters from potato, fruit juice, and lettuce processing. Additionally, the production of carotenoids as high-valuemore » by-products was examined. All evaluated wastewaters met the general criteria for microbial lipid production. However, no significant increase in lipid content was observed, probably due to lack of available carbon in wastewaters from fruit juice and lettuce processing, and excess of available nitrogen in potato processing wastewater, respectively. During growth on wastewaters from fruit juice and lettuce processing the carotenoid content increased significantly in the first 48 hours. The relations between carbon content, nitrogen content, and carotenoid production need to be further assessed. For economic viability, lipid and carotenoid production needs to be increased significantly. Lastly, the screening of feedstocks should be extended to other wastewaters.« less
Improved silicon nitride for advanced heat engines
NASA Technical Reports Server (NTRS)
Yeh, Hun C.; Fang, Ho T.
1987-01-01
The technology base required to fabricate silicon nitride components with the strength, reliability, and reproducibility necessary for actual heat engine applications is presented. Task 2 was set up to develop test bars with high Weibull slope and greater high temperature strength, and to conduct an initial net shape component fabrication evaluation. Screening experiments were performed in Task 7 on advanced materials and processing for input to Task 2. The technical efforts performed in the second year of a 5-yr program are covered. The first iteration of Task 2 was completed as planned. Two half-replicated, fractional factorial (2 sup 5), statistically designed matrix experiments were conducted. These experiments have identified Denka 9FW Si3N4 as an alternate raw material to GTE SN502 Si3N4 for subsequent process evaluation. A detailed statistical analysis was conducted to correlate processing conditions with as-processed test bar properties. One processing condition produced a material with a 97 ksi average room temperature MOR (100 percent of goal) with 13.2 Weibull slope (83 percent of goal); another condition produced 86 ksi (6 percent over baseline) room temperature strength with a Weibull slope of 20 (125 percent of goal).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poludniowski, Gavin G.; Evans, Philip M.
2013-04-15
Purpose: Monte Carlo methods based on the Boltzmann transport equation (BTE) have previously been used to model light transport in powdered-phosphor scintillator screens. Physically motivated guesses or, alternatively, the complexities of Mie theory have been used by some authors to provide the necessary inputs of transport parameters. The purpose of Part II of this work is to: (i) validate predictions of modulation transform function (MTF) using the BTE and calculated values of transport parameters, against experimental data published for two Gd{sub 2}O{sub 2}S:Tb screens; (ii) investigate the impact of size-distribution and emission spectrum on Mie predictions of transport parameters; (iii)more » suggest simpler and novel geometrical optics-based models for these parameters and compare to the predictions of Mie theory. A computer code package called phsphr is made available that allows the MTF predictions for the screens modeled to be reproduced and novel screens to be simulated. Methods: The transport parameters of interest are the scattering efficiency (Q{sub sct}), absorption efficiency (Q{sub abs}), and the scatter anisotropy (g). Calculations of these parameters are made using the analytic method of Mie theory, for spherical grains of radii 0.1-5.0 {mu}m. The sensitivity of the transport parameters to emission wavelength is investigated using an emission spectrum representative of that of Gd{sub 2}O{sub 2}S:Tb. The impact of a grain-size distribution in the screen on the parameters is investigated using a Gaussian size-distribution ({sigma}= 1%, 5%, or 10% of mean radius). Two simple and novel alternative models to Mie theory are suggested: a geometrical optics and diffraction model (GODM) and an extension of this (GODM+). Comparisons to measured MTF are made for two commercial screens: Lanex Fast Back and Lanex Fast Front (Eastman Kodak Company, Inc.). Results: The Mie theory predictions of transport parameters were shown to be highly sensitive to both grain size and emission wavelength. For a phosphor screen structure with a distribution in grain sizes and a spectrum of emission, only the average trend of Mie theory is likely to be important. This average behavior is well predicted by the more sophisticated of the geometrical optics models (GODM+) and in approximate agreement for the simplest (GODM). The root-mean-square differences obtained between predicted MTF and experimental measurements, using all three models (GODM, GODM+, Mie), were within 0.03 for both Lanex screens in all cases. This is excellent agreement in view of the uncertainties in screen composition and optical properties. Conclusions: If Mie theory is used for calculating transport parameters for light scattering and absorption in powdered-phosphor screens, care should be taken to average out the fine-structure in the parameter predictions. However, for visible emission wavelengths ({lambda} < 1.0 {mu}m) and grain radii (a > 0.5 {mu}m), geometrical optics models for transport parameters are an alternative to Mie theory. These geometrical optics models are simpler and lead to no substantial loss in accuracy.« less
Modality dependence and intermodal transfer in the Corsi Spatial Sequence Task: Screen vs. Floor.
Röser, Andrea; Hardiess, Gregor; Mallot, Hanspeter A
2016-07-01
Four versions of the Corsi Spatial Sequence Task (CSST) were tested in a complete within-subject design, investigating whether participants' performance depends on the modality of task presentation and reproduction that put different demands on spatial processing. Presentation of the sequence (encoding phase) and the reproduction (recall phase) were each carried out either on a computer screen or on the floor of a room, involving actual walking in the recall phase. Combinations of the two different encoding and recall procedures result in the modality conditions Screen-Screen, Screen-Floor, Floor-Screen, and Floor-Floor. Results show the expected decrease in performance with increasing sequence length, which is likely due to processing limitations of working memory. We also found differences in performance between the modality conditions indicating different involvements of spatial working memory processes. Participants performed best in the Screen-Screen modality condition. Floor-Screen and Floor-Floor modality conditions require additional working memory resources for reference frame transformation and spatial updating, respectively; the resulting impairment of the performance was about the same in these two conditions. Finally, the Screen-Floor modality condition requires both types of additional spatial demands and led to the poorest performance. Therefore, we suggest that besides the well-known spatial requirements of CSST, additional working memory resources are demanded in walking CSST supporting processes such as spatial updating, mental rotation, reference frame transformation, and the control of walking itself.
Schiffman, Mark; Katki, Hormuzd A.; Castle, Philip E.; Fetterman, Barbara; Wentzensen, Nicolas; Poitras, Nancy E.; Lorey, Thomas; Cheung, Li C.; Kinney, Walter K.
2014-01-01
Primary human papillomavirus (HPV) testing (without concurrent Pap tests) every 3 years is under consideration in the United States as an alternative to the two recommended cervical cancer screening strategies: primary Pap testing every 3 years, or concurrent Pap and HPV testing (“cotesting”) every 5 years. Using logistic regression and Weibull survival models, we estimated and compared risks of cancer and cervical intraepithelial neoplasia grade 3 or worse (CIN3+) for the three strategies among 1011092 women aged 30 to 64 years testing HPV-negative and/or Pap-negative in routine screening at Kaiser Permanente Northern California since 2003. All statistical tests were two sided. Three-year risks following an HPV-negative result were lower than 3-year risks following a Pap-negative result (CIN3+ = 0.069% vs 0.19%, P < .0001; Cancer = 0.011% vs 0.020%, P < .0001) and 5-year risks following an HPV-negative/Pap-negative cotest (CIN3+ = 0.069% vs 0.11%, P < .0001; Cancer = 0.011% vs 0.014%, P = .21). These findings suggest that primary HPV testing merits consideration as another alternative for cervical screening. PMID:25038467
Gage, Julia C; Schiffman, Mark; Katki, Hormuzd A; Castle, Philip E; Fetterman, Barbara; Wentzensen, Nicolas; Poitras, Nancy E; Lorey, Thomas; Cheung, Li C; Kinney, Walter K
2014-08-01
Primary human papillomavirus (HPV) testing (without concurrent Pap tests) every 3 years is under consideration in the United States as an alternative to the two recommended cervical cancer screening strategies: primary Pap testing every 3 years, or concurrent Pap and HPV testing ("cotesting") every 5 years. Using logistic regression and Weibull survival models, we estimated and compared risks of cancer and cervical intraepithelial neoplasia grade 3 or worse (CIN3+) for the three strategies among 1011092 women aged 30 to 64 years testing HPV-negative and/or Pap-negative in routine screening at Kaiser Permanente Northern California since 2003. All statistical tests were two sided. Three-year risks following an HPV-negative result were lower than 3-year risks following a Pap-negative result (CIN3+ = 0.069% vs 0.19%, P < .0001; Cancer = 0.011% vs 0.020%, P < .0001) and 5-year risks following an HPV-negative/Pap-negative cotest (CIN3+ = 0.069% vs 0.11%, P < .0001; Cancer = 0.011% vs 0.014%, P = .21). These findings suggest that primary HPV testing merits consideration as another alternative for cervical screening. © Published by Oxford University Press 2014.
Northrup, Jason C.; Lapierre, Coady; Kirk, Jeffrey; Rae, Cosette
2015-01-01
The Internet Process Addiction Test (IPAT) was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term “Internet addiction” is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT) demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed. PMID:26226007
Northrup, Jason C; Lapierre, Coady; Kirk, Jeffrey; Rae, Cosette
2015-07-28
The Internet Process Addiction Test (IPAT) was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term "Internet addiction" is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT) demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.
Breast Cancer Screening in an Era of Personalized Regimens
Onega, Tracy; Beaber, Elisabeth F.; Sprague, Brian L.; Barlow, William E.; Haas, Jennifer S.; Tosteson, Anna N.A.; Schnall, Mitchell D.; Armstrong, Katrina; Schapira, Marilyn M.; Geller, Berta; Weaver, Donald L.; Conant, Emily F.
2014-01-01
Breast cancer screening holds a prominent place in public health, health care delivery, policy, and women’s health care decisions. Several factors are driving shifts in how population-based breast cancer screening is approached, including advanced imaging technologies, health system performance measures, health care reform, concern for “overdiagnosis,” and improved understanding of risk. Maximizing benefits while minimizing the harms of screening requires moving from a “1-size-fits-all” guideline paradigm to more personalized strategies. A refined conceptual model for breast cancer screening is needed to align women’s risks and preferences with screening regimens. A conceptual model of personalized breast cancer screening is presented herein that emphasizes key domains and transitions throughout the screening process, as well as multilevel perspectives. The key domains of screening awareness, detection, diagnosis, and treatment and survivorship are conceptualized to function at the level of the patient, provider, facility, health care system, and population/policy arena. Personalized breast cancer screening can be assessed across these domains with both process and outcome measures. Identifying, evaluating, and monitoring process measures in screening is a focus of a National Cancer Institute initiative entitled PROSPR (Population-based Research Optimizing Screening through Personalized Regimens), which will provide generalizable evidence for a risk-based model of breast cancer screening, The model presented builds on prior breast cancer screening models and may serve to identify new measures to optimize benefits-to-harms tradeoffs in population-based screening, which is a timely goal in the era of health care reform. PMID:24830599
May, Folasade P; Yano, Elizabeth M; Provenzale, Dawn; Neil Steers, W; Washington, Donna L
2017-08-01
Colorectal cancer (CRC) is a deadly but largely preventable disease. Screening improves outcomes, but screening rates vary across healthcare coverage models. In the Veterans Health Administration (VA), screening rates are high; however, it is unknown how CRC screening rates compare for Veterans with other types of healthcare coverage. To determine whether Veterans with Veteran-status-related coverage (VA, military, TRICARE) have higher rates of CRC screening than Veterans with alternate sources of healthcare coverage. We conducted a cross-sectional analysis of Veterans 50-75 years from the 2014 Behavioral Risk Factor Surveillance System survey. We examined CRC screening rates and screening modalities. We performed multivariable logistic regression to identify the role of coverage type, demographics, and clinical factors on screening status. The cohort included 22,138 Veterans. Of these, 76.7% reported up-to-date screening. Colonoscopy was the most common screening modality (83.7%). Screening rates were highest among Veterans with Veteran-status-related coverage (82.3%), as was stool-based screening (10.8%). The adjusted odds of up-to-date screening among Veterans with Veteran-status-related coverage were 83% higher than among Veterans with private coverage (adjusted OR = 1.83, 95% CI = 1.52-2.22). Additional predictors of screening included older age, black race, high income, access to medical care, frequent medical visits, and employed or married status. CRC screening rates were highest among Veterans with Veteran-status-related coverage. High CRC screening rates among US Veterans may be related to system-level characteristics of VA and military care. Insight to these system-level characteristics may inform mechanisms to improve CRC screening in non-VA settings.
Björnsdotter, Maria K; Jonker, Willem; Legradi, Jessica; Kool, Jeroen; Ballesteros-Gómez, Ana
2017-12-01
Thermal paper contains potentially toxic additives, such as bisphenol A (BPA), as a common color developer. Because of its known endocrine disrupting effects, structural analogues to BPA, such as bisphenol S (BPS), D-8 and Pergafast 201, have been used as alternatives, but little is known about the presence and toxicological effects of alternatives other than BPS. In this study, thermal paper is screened by direct probe ambient mass spectrometry (rapid pre-screening method not requiring sample preparation) and by liquid chromatography (LC) with high resolution time-of flight (TOF-MS) mass spectrometry. Cash receipts and other thermal paper products (cinema tickets, boarding passes and luggage tags) were analyzed. Besides BPA and BPS, other developers only recently reported (Pergafast 201, D-8) or to the best of our knowledge not reported before (D-90, TGSA, BPS-MAE) were frequently found as well as some related unreported impurities (2,4-BPS that is a BPS related impurity and a TGSA related impurity). To gain some insight into the potential estrogenicity of the detected developers, a selection of extracts was further analyzed using a LC-nanofractionation platform in combination with cell-based bioassay testing. These preliminary results seems to indicate very low or absence of estrogenic activity for Pergafast 201, D-8, D-90, TGSA and BPS-MAE in comparison to BPA and BPS, although further dose-response tests with authentic standards are required to confirm these results. Compounds for which standards were available were also tested for developmental toxicity and neurotoxicity using zebrafish (Danio rerio) embryos. TGSA and D-8 induced similar teratogenic effects as BPA in zebrafish embryos. BPS and 2,4-BPS did not induce any developmental effects but 2,4-BPS did alter the locomotor activity at the tested concentration. Our findings suggest that the alternatives used as alternatives to BPA (except BPS) might not be estrogenic. However, TGSA and D-8 showed abnormal developmental effects similar to BPA. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Rezy, B. J.; Meyers, J. E.; Tucker, J. R.; Stuckas, S. J.
1976-01-01
An analysis was conducted to screen, evaluate, and select three engine exhaust emission reduction concepts from a group of 14 candidate alternatives. A comprehensive literature search was conducted to survey the emission reduction technology state-of-the-art and establish contact with firms working on intermittent combustion engine development and pollution reduction problems. Concept development, advantages, disadvantages, and expected emission reduction responses are stated. A set of cost effectiveness criteria was developed, appraised for relative importance, and traded off against each concept so that its merit could be determined. A decision model was used to aid the evaluators in managing the criteria, making consistent judgements, calculating merit scores, and ranking the concepts. An Improved Fuel Injection System, Improved Cooling Combustion Chamber, and a Variable Timing Ignition System were recommended to NASA for approval and further concept development. An alternate concept, Air Injection, was also recommended.
Turker, Hakan; Yıldırım, Arzu Birinci
2015-01-01
The antibacterial activity of ethanolic and aqueous crude extracts from 36 plants in Turkey, including seven endemic species, against fish pathogens was studied using the disc diffusion assay. The extract that was most active against all microbial strains, except Aeromonas salmonicida, was that of Dorycnium pentaphyllum. Some of the extracts also showed a very broad spectrum of potent antimicrobial activity. The extract of Anemone nemorosa showed the highest antimicrobial activity against Vibrio anguillarum. V. anguillarum, a Gram-negative bacterium, appeared to be the most susceptible to the plant extracts used in this experiment. To the best of our knowledge, this is the first report on the antimicrobial activity of 11 of the studied plants. The preliminary screening assay indicated that some of the Turkish plants with antibacterial properties may offer alternative therapeutic agents against bacterial infections in aquaculture industry. PMID:26019642
Canada's new drug-impaired driving law: the need to consider other approaches.
Solomon, Robert; Chamberlain, Erika
2014-01-01
The objects of this study were: To review the state of drug-impaired driving in Canada, particularly in light of the 2008 amendments to the Criminal Code, which authorized police to demand standardized field sobriety testing and drug recognition evaluations, and to consider whether alternative enforcement models would be more effective in terms of detecting and prosecuting drug-impaired drivers and thereby achieve greater deterrence. This article provides a review of survey data, roadside screening studies, and postmortem reports that indicate the prevalence of driving after drug use in Canada. It evaluates the Criminal Code's 2008 amendments and their impact on charges and convictions for drug-impaired driving. It then reviews some alternative enforcement models for drug-impaired driving that have been adopted in other jurisdictions, particularly toxicological testing, and evaluates them against Canada's social, political, and constitutional framework. Survey data, roadside screening studies, and postmortem reports indicate that driving after drug use is commonplace and is now more prevalent among young people than driving after drinking. Unfortunately, the 2008 Criminal Code amendments have not had their desired effects. The measures have proven to be costly, time-consuming, and cumbersome, and are readily susceptible to challenge in the courts. Accordingly, the charge rates for drug-impaired driving remain extremely low, and the law has had minimal deterrent effects. The review of alternative enforcement models suggests that a system of random roadside saliva screening, somewhat similar to the model used in Victoria, Australia, will be the most effective in terms of detecting and prosecuting drug-impaired drivers and most consistent with Canada's legal and constitutional system. Canada should establish per se limits for the most commonly used drugs, enforceable through a system of screening and evidentiary tests. This will be more efficient and cost-effective and will result in more reliable evidence for criminal trials. Although this system will inevitably be subject to constitutional challenge, existing case law suggests that it should be upheld as a reasonable limit on constitutional rights.
Lommen, Arjen; van der Kamp, Henk J; Kools, Harrie J; van der Lee, Martijn K; van der Weg, Guido; Mol, Hans G J
2012-11-09
A new alternative data processing tool set, metAlignID, is developed for automated pre-processing and library-based identification and concentration estimation of target compounds after analysis by comprehensive two-dimensional gas chromatography with mass spectrometric detection. The tool set has been developed for and tested on LECO data. The software is developed to run multi-threaded (one thread per processor core) on a standard PC (personal computer) under different operating systems and is as such capable of processing multiple data sets simultaneously. Raw data files are converted into netCDF (network Common Data Form) format using a fast conversion tool. They are then preprocessed using previously developed algorithms originating from metAlign software. Next, the resulting reduced data files are searched against a user-composed library (derived from user or commercial NIST-compatible libraries) (NIST=National Institute of Standards and Technology) and the identified compounds, including an indicative concentration, are reported in Excel format. Data can be processed batch wise. The overall time needed for conversion together with processing and searching of 30 raw data sets for 560 compounds is routinely within an hour. The screening performance is evaluated for detection of pesticides and contaminants in raw data obtained after analysis of soil and plant samples. Results are compared to the existing data-handling routine based on proprietary software (LECO, ChromaTOF). The developed software tool set, which is freely downloadable at www.metalign.nl, greatly accelerates data-analysis and offers more options for fine-tuning automated identification toward specific application needs. The quality of the results obtained is slightly better than the standard processing and also adds a quantitative estimate. The software tool set in combination with two-dimensional gas chromatography coupled to time-of-flight mass spectrometry shows great potential as a highly-automated and fast multi-residue instrumental screening method. Copyright © 2012 Elsevier B.V. All rights reserved.
e-Drug3D: 3D structure collections dedicated to drug repurposing and fragment-based drug design.
Pihan, Emilie; Colliandre, Lionel; Guichou, Jean-François; Douguet, Dominique
2012-06-01
In the drug discovery field, new uses for old drugs, selective optimization of side activities and fragment-based drug design (FBDD) have proved to be successful alternatives to high-throughput screening. e-Drug3D is a database of 3D chemical structures of drugs that provides several collections of ready-to-screen SD files of drugs and commercial drug fragments. They are natural inputs in studies dedicated to drug repurposing and FBDD. e-Drug3D collections are freely available at http://chemoinfo.ipmc.cnrs.fr/e-drug3d.html either for download or for direct in silico web-based screenings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fasiello, Matteo; Vlah, Zvonimir
A specific value for the cosmological constant Λ can account for late-time cosmic acceleration. However, motivated by the so-called cosmological constant problem(s), several alternative mechanisms have been explored. To date, a host of well-studied dynamical dark energy and modified gravity models exists. Going beyond ΛCDM often comes with additional degrees of freedom (dofs). For these to pass existing observational tests, an efficient screening mechanism must be in place. Furthermore, the linear and quasi-linear regimes of structure formation are ideal probes of such dofs and can capture the onset of screening. We propose here a semi-phenomenological “filter” to account for screeningmore » dynamics on LSS observables, with special emphasis on Vainshtein-type screening.« less
Comparison of Three Cognitive Screening Tools in Older Urban and Regional Aboriginal Australians.
Radford, Kylie; Mack, Holly A; Draper, Brian; Chalkley, Simon; Delbaere, Kim; Daylight, Gail; Cumming, Robert G; Bennett, Hayley; Broe, Gerald A
2015-01-01
Validated cognitive screening tools for use in urban and regional Aboriginal populations in Australia are lacking. In a cross-sectional community-based study, 235 participants were assessed on the Mini-Mental State Examination (MMSE), the Rowland Universal Dementia Assessment Scale (RUDAS) and an urban modification of the Kimberley Indigenous Cognitive Assessment (mKICA). Performance on these cognitive screening tools was compared to dementia diagnosis by clinical consensus. All tests were culturally acceptable with good psychometric properties. Receiver operating characteristic curve analyses revealed that the MMSE and mKICA were the most accurate. The MMSE is an effective cognitive screening tool in urban Aboriginal populations. The mKICA is a good alternative when illiteracy, language or cultural considerations deem it appropriate. The RUDAS also has adequate validity in this population. © 2015 S. Karger AG, Basel.
Howard, Barbara J; Sturner, Raymond
2017-12-01
To describe benefits and problems with screening and addressing developmental and behavioral problems in primary care and using an online clinical process support system as a solution. Screening has been found to have various implementation barriers including time costs, accuracy, workflow and knowledge of tools. In addition, training of clinicians in dealing with identified issues is lacking. Patients disclose more to and prefer computerized screening. An online clinical process support system (CHADIS) shows promise in addressing these issues. Use of a comprehensive panel of online pre-visit screens; linked decision support to provide moment-of-care training; and post-visit activities and resources for patient-specific education, monitoring and care coordination is an efficient way to make the entire process of screening and follow up care feasible in primary care. CHADIS fulfills these requirements and provides Maintenance of Certification credit to physicians as well as added income for screening efforts.
The effects of gray scale image processing on digital mammography interpretation performance.
Cole, Elodia B; Pisano, Etta D; Zeng, Donglin; Muller, Keith; Aylward, Stephen R; Park, Sungwook; Kuzmiak, Cherie; Koomen, Marcia; Pavic, Dag; Walsh, Ruth; Baker, Jay; Gimenez, Edgardo I; Freimanis, Rita
2005-05-01
To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations-manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE-were presented in soft copy display. There were three radiologists per presentation. Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type.
Monfregola, Luca; Vitale, Rosa Maria; Amodeo, Pietro; De Luca, Stefania
2009-10-01
The discovery of pharmaceutical agents is a complex, lengthy and costly process, critically depending on the availability of rapid and efficient screening methods. In particular, when targets are large, multidomain proteins, their complexity may affect unfavorably technical feasibility, costs and unambiguity of binding test interpretation. A possible strategy to overcome these problems relies on molecular design of receptor fragments that are: sensible targets for ligand screenings, conformationally stable also as standalone domains, easily synthesized and immobilized on chip for Biacore experiments. An additional desirable feature for new ligands is the ability of selectively targeting alternative conformational states typical of many proteins. To test the feasibility of such approach on a case with potential applicative interest, we developed a surface plasmon resonance (SPR)-based screening method for drug candidates toward HER2, a Tyr-kinase receptor targeted in anticancer therapies. HER2 was mimicked by HER2-DIVMP, a modified fragment of it immobilized onto the sensor surface specifically modeling HER2 domain IV in its bounded form, designed by structural comparison of HER2 alone and in complex with Herceptin, a monoclonal therapeutic anti-HER2 antibody. This design and its implementation in SPR devices was validated by investigating Herceptin- HER2-DIVMP affinity, measuring its dissociation constant (K(D)=19.2 nM). An efficient synthetic procedure to prepare the HER2-DIVMP peptide was also developed. The HER2-DIVMP conformational stability suggested by experimental and computational results, makes it also a valuable candidate as a mold to design new molecules selectively targeting domain IV of HER2.
Spjuth, Ola; Karlsson, Andreas; Clements, Mark; Humphreys, Keith; Ivansson, Emma; Dowling, Jim; Eklund, Martin; Jauhiainen, Alexandra; Czene, Kamila; Grönberg, Henrik; Sparén, Pär; Wiklund, Fredrik; Cheddad, Abbas; Pálsdóttir, Þorgerður; Rantalainen, Mattias; Abrahamsson, Linda; Laure, Erwin; Litton, Jan-Eric; Palmgren, Juni
2017-09-01
We provide an e-Science perspective on the workflow from risk factor discovery and classification of disease to evaluation of personalized intervention programs. As case studies, we use personalized prostate and breast cancer screenings. We describe an e-Science initiative in Sweden, e-Science for Cancer Prevention and Control (eCPC), which supports biomarker discovery and offers decision support for personalized intervention strategies. The generic eCPC contribution is a workflow with 4 nodes applied iteratively, and the concept of e-Science signifies systematic use of tools from the mathematical, statistical, data, and computer sciences. The eCPC workflow is illustrated through 2 case studies. For prostate cancer, an in-house personalized screening tool, the Stockholm-3 model (S3M), is presented as an alternative to prostate-specific antigen testing alone. S3M is evaluated in a trial setting and plans for rollout in the population are discussed. For breast cancer, new biomarkers based on breast density and molecular profiles are developed and the US multicenter Women Informed to Screen Depending on Measures (WISDOM) trial is referred to for evaluation. While current eCPC data management uses a traditional data warehouse model, we discuss eCPC-developed features of a coherent data integration platform. E-Science tools are a key part of an evidence-based process for personalized medicine. This paper provides a structured workflow from data and models to evaluation of new personalized intervention strategies. The importance of multidisciplinary collaboration is emphasized. Importantly, the generic concepts of the suggested eCPC workflow are transferrable to other disease domains, although each disease will require tailored solutions. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association.
2011-01-01
Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473
Martínez, Oscar; Sánchez, Antoni; Font, Xavier; Barrena, Raquel
2018-06-01
2-Phenylethanol (2-PE) and 2-phenethyl acetate (2-PEA) are important aroma compounds widely used in food and cosmetic industries due to their rose-like odor. Nowadays, due to the growing demand for natural products, the development of bioprocesses for obtaining value-added compounds has become of great significance. 2-PE and 2-PEA can be produced through the biotransformation of L-phenylalanine using the generally recognized as safe strain Kluyveromyces marxianus. L-phenylalanine bioconversion systems have been typically focused on submerged fermentation processes (SmF), but there is no information about other alternative productive approaches. Here, the solid-state fermentation (SSF) of sugarcane bagasse supplemented with L-phenylalanine was investigated as a sustainable alternative for producing 2-PE and 2-PEA in a residue-based system using Kluyveromyces marxianus as inoculum. An initial screening of the operational variables indicated that air supply, temperature, and initial moisture content significantly affect the product yield. Besides, it was found that the feeding strategy also affects the production and the efficiency of the process. While a basic batch system produced 16 mg products per gram of residue (dry basis), by using split feeding strategies (fed-batch) of only sugarcane bagasse, a maximum of 18.4 mg Products g -1 residue were achieved. Increase in product yield was also accompanied by an increase in the consumption efficiency of nutrients and precursor. The suggested system results as effective as other more complex SmF systems to obtain 2-PE and 2-PEA, showing the feasibility of SSF as an alternative for producing these compounds through the valorization of an agro-industrial residue.
Pargett, Michael; Rundell, Ann E.; Buzzard, Gregery T.; Umulis, David M.
2014-01-01
Discovery in developmental biology is often driven by intuition that relies on the integration of multiple types of data such as fluorescent images, phenotypes, and the outcomes of biochemical assays. Mathematical modeling helps elucidate the biological mechanisms at play as the networks become increasingly large and complex. However, the available data is frequently under-utilized due to incompatibility with quantitative model tuning techniques. This is the case for stem cell regulation mechanisms explored in the Drosophila germarium through fluorescent immunohistochemistry. To enable better integration of biological data with modeling in this and similar situations, we have developed a general parameter estimation process to quantitatively optimize models with qualitative data. The process employs a modified version of the Optimal Scaling method from social and behavioral sciences, and multi-objective optimization to evaluate the trade-off between fitting different datasets (e.g. wild type vs. mutant). Using only published imaging data in the germarium, we first evaluated support for a published intracellular regulatory network by considering alternative connections of the same regulatory players. Simply screening networks against wild type data identified hundreds of feasible alternatives. Of these, five parsimonious variants were found and compared by multi-objective analysis including mutant data and dynamic constraints. With these data, the current model is supported over the alternatives, but support for a biochemically observed feedback element is weak (i.e. these data do not measure the feedback effect well). When also comparing new hypothetical models, the available data do not discriminate. To begin addressing the limitations in data, we performed a model-based experiment design and provide recommendations for experiments to refine model parameters and discriminate increasingly complex hypotheses. PMID:24626201
Cost-Effectiveness Analysis of Breast Cancer Screening in Rural Iran.
Zehtab, Nooshin; Jafari, Mohammad; Barooni, Mohsen; Nakhaee, Nouzar; Goudarzi, Reza; Larry Zadeh, Mohammad Hassan
2016-01-01
Although breast cancer is the most common cancer in women, economic evaluation of breast cancer screening is not fully addressed in developing countries. The main objective of the present study was to analyze the cost-effectiveness of breast cancer screening using mammography in 35-69 year old women in an Iranian setting. This was an economic evaluation study assessing the cost-effectiveness of a population-based screening program in 35-69 year old women residing in rural areas of South east Iran. The study was conducted from the perspective of policy-makers of insurance. The study population consisted of 35- to 69-year old women in rural areas of Kerman with a population of about 19,651 in 2013. The decision tree modeling and economic evaluation software were used for cost-effectiveness and sensitivity analyses of the interventions. The total cost of the screening program was 7,067.69 US$ and the total effectiveness for screening and no-screening interventions was 0.06171 and 0.00864 disability adjusted life years averted, respectively. The average cost-effectiveness ratio DALY averted US$ for screening intervention was 7,7082.5 US$ per DALY averted and 589,027 US $ for no-screening intervention. The incremental cost-effectiveness ratio DALY averted was 6,264 US$ per DALY averted for screening intervention compared with no-screening intervention. Although the screening intervention is more cost-effective than the alternative (no- screening) strategy, it seems that including breast cancer screening program in health insurance package may not be recommended as long as the target group has a low participation rate.
Danyliv, Andriy; Gillespie, Paddy; O'Neill, Ciaran; Tierney, Marie; O'Dea, Angela; McGuire, Brian E; Glynn, Liam G; Dunne, Fidelma P
2016-03-01
The aim of the study was to assess the cost-effectiveness of screening for gestational diabetes mellitus (GDM) in primary and secondary care settings, compared with a no-screening option, in the Republic of Ireland. The analysis was based on a decision-tree model of alternative screening strategies in primary and secondary care settings. It synthesised data generated from a randomised controlled trial (screening uptake) and from the literature. Costs included those relating to GDM screening and treatment, and the care of adverse outcomes. Effects were assessed in terms of quality-adjusted life years (QALYs). The impact of the parameter uncertainty was assessed in a range of sensitivity analyses. Screening in either setting was found to be superior to no screening, i.e. it provided for QALY gains and cost savings. Screening in secondary care was found to be superior to screening in primary care, providing for modest QALY gains of 0.0006 and a saving of €21.43 per screened case. The conclusion held with high certainty across the range of ceiling ratios from zero to €100,000 per QALY and across a plausible range of input parameters. The results of this study demonstrate that implementation of universal screening is cost-effective. This is an argument in favour of introducing a properly designed and funded national programme of screening for GDM, although affordability remains to be assessed. In the current environment, screening for GDM in secondary care settings appears to be the better solution in consideration of cost-effectiveness.
Benigni, Romualdo; Bossa, Cecilia; Tcheremenskaia, Olga
2013-01-01
The study of the chemical carcinogenesis mechanisms and the design of efficient prevention strategies and measures are of crucial importance to protect human health. The long-term carcinogenesis bioassays have played a central role in protecting human health, but for ethical and practical reasons their use is dramatically diminishing, and the genotoxicity short-term tests have taken the pivotal role in the pre-screening of carcinogenicity. However, there is evidence that this strategy is not sensitive enough to detect all genotoxic carcinogens and it cannot detect nongenotoxic carcinogens. In a previous article, we have shown that an integrated strategy consisting of the in vitro Ames and Syrian Hamster Embryo cells transformation assays, combined with structure-activity relationships, is a valid alternative to the present pre-screening strategies. Here, we expand the previous investigation by (i) including results of cell transformation assays on inorganics, together with an additional assay (Bhas 42), and (ii) considering new structural alerts for nongenotoxic carcinogenicity. We also present a new analysis on global relationships between toxicological endpoints. The new results confirm that the previously proposed integrated, alternative strategy is an efficient tool to identify both genotoxic and nongenotoxic carcinogens, with an estimated 90-95% sensitivity.
Rajan, Shobana; Khanna, Ashish; Argalious, Maged; Kimatian, Stephen J; Mascha, Edward J; Makarova, Natalya; Nada, Eman M; Elsharkawy, Hesham; Firoozbakhsh, Farhad; Avitsian, Rafi
2016-02-01
Simulation-based learning is emerging as an alternative educational tool in this era of a relative shortfall of teaching anesthesiologists. The objective of the study is to assess whether screen-based (interactive computer simulated) case scenarios are more effective than problem-based learning discussions (PBLDs) in improving test scores 4 and 8 weeks after these interventions in anesthesia residents during their first neuroanesthesia rotation. Prospective, nonblinded quasi-crossover study. Cleveland Clinic. Anesthesiology residents. Two case scenarios were delivered from the Anesoft software as screen-based sessions, and parallel scripts were developed for 2 PBLDs. Each resident underwent both types of training sessions, starting with the PBLD session, and the 2 cases were alternated each month (ie, in 1 month, the screen-based intervention used case 1 and the PBLD used case 2, and vice versa for the next month). Test scores before the rotation (baseline), immediately after the rotation (4 weeks after the start of the rotation), and 8 weeks after the start of rotation were collected on each topic from each resident. The effect of training method on improvement in test scores was assessed using a linear mixed-effects model. Compared to the departmental standard of PBLD, the simulation method did not improve either the 4- or 8-week mean test scores (P = .41 and P = .40 for training method effect on 4- and 8-week scores, respectively). Resident satisfaction with the simulation module on a 5-point Likert scale showed subjective evidence of a positive impact on resident education. Screen-based simulators were not more effective than PBLD for education during the neuroanesthesia rotation in anesthesia residency. Copyright © 2016 Elsevier Inc. All rights reserved.
Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone.
Harvey, Virginia L; Egerton, Victoria M; Chamberlain, Andrew T; Manning, Phillip L; Buckley, Michael
2016-01-01
Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six (14)C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated (14)C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 1(4)C analysis.
Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone
Harvey, Virginia L.; Egerton, Victoria M.; Chamberlain, Andrew T.; Manning, Phillip L.; Buckley, Michael
2016-01-01
Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six 14C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated 14C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 14C analysis. PMID:26938469
Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.
2003-01-01
During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.
Fasting glycaemia to simplify screening for gestational diabetes.
Ryser Rüetschi, J; Jornayvaz, F R; Rivest, R; Huhn, E A; Irion, O; Boulvain, M
2016-12-01
Recommendations in Switzerland on screening for gestational diabetes endorse the International Association of Diabetes in Pregnancy Study Group consensus. As universal testing is time consuming and glucose loading is unpleasant, the recommendations include a simplification, not performing the glucose loading in women with fasting glycaemia <4.4 mmol/l. Our objective was to evaluate the diagnostic performance of this simplified strategy, compared with the complete test, in our population with a low prevalence of gestational diabetes. We collected 2298 complete 75-g glucose tolerance tests. We simulated stopping the test, so avoiding the glucose loading and further glycaemia, if fasting glycaemia was <4.4 or ≥5.1 mmol/l. Unselected pregnant women from Geneva and Basel, at 24-28 weeks of gestation. We calculated the sensitivity, and the percentage of women who would avoid the complete test with the strategy based on fasting glycaemia. The prevalence of gestational diabetes was 10.9% in our population. Among 251 women with gestational diabetes, fasting glycaemia was ≥5.1 mmol/l in 119 women (47.4%), between 4.4 and <5.1 mmol/l in 78 women (31.1%) and <4.4 mmol/l in 54 women (21.5%). Proceeding with the complete test only in women with fasting glycaemia between 4.4 and <5.1 mmol/l will result in a sensitivity of 78.5%. This strategy would avoid glucose loading in 63.8% of women. Screening with fasting glycaemia is an attractive alternative to universal screening with the complete 75-g glucose tolerance test. This strategy is, however, slightly less sensitive than previously reported in higher-risk populations. Fasting glycaemia can be considered as an alternative to the complete test for gestational diabetes screening. © 2016 Royal College of Obstetricians and Gynaecologists.
Can Untargeted Metabolomics Be Utilized in Drug Discovery/Development?
Caldwell, Gary W; Leo, Gregory C
2017-01-01
Untargeted metabolomics is a promising approach for reducing the significant attrition rate for discovering and developing drugs in the pharmaceutical industry. This review aims to highlight the practical decision-making value of untargeted metabolomics for the advancement of drug candidates in drug discovery/development including potentially identifying and validating novel therapeutic targets, creating alternative screening paradigms, facilitating the selection of specific and translational metabolite biomarkers, identifying metabolite signatures for the drug efficacy mechanism of action, and understanding potential drug-induced toxicity. The review provides an overview of the pharmaceutical process workflow to discover and develop new small molecule drugs followed by the metabolomics process workflow that is involved in conducting metabolomics studies. The pros and cons of the major components of the pharmaceutical and metabolomics workflows are reviewed and discussed. Finally, selected untargeted metabolomics literature examples, from primarily 2010 to 2016, are used to illustrate why, how, and where untargeted metabolomics can be integrated into the drug discovery/preclinical drug development process. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Broderick, Robert Joseph; Quiroz, Jimmy Edward; Reno, Matthew J.
2015-11-01
The third solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utility Commission (CPUC) is supporting the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with collaboration from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E), in research to improve the Utility Application Review and Approval process for interconnecting distributed energy resources to the distribution system. Currently this process is the most time - consuming of any step on the path to generating power onmore » the distribution system. This CSI RD&D solicitation three project has completed the tasks of collecting data from the three utilities, clustering feeder characteristic data to attain representative feeders, detailed modeling of 16 representative feeders, analysis of PV impacts to those feeders, refinement of current screening processes, and validation of those suggested refinements. In this report each task is summarized to produce a final summary of all components of the overall project.« less
ERIC Educational Resources Information Center
Fine, Leonard W.; And Others
1977-01-01
Discusses the use of lap-dissolve projection to give students pre-laboratory instruction on an upcoming experiment. In this technique, two slide projectors are operated alternately so that one visual image fades away while the next appears on the same screen area. (MLH)
Coed Football: Hazards, Implications, and Alternatives.
ERIC Educational Resources Information Center
Falls, Harold B.
1986-01-01
Football, it is argued, is too dangerous for most girls and for many boys. Data on male-female differences in size, speed, and strength are reviewed. A preparticipation screening program with equal requirements for both sexes is proposed. (Author/MT)
BIOLOGICALLY-BASED RAPID SCREENING METHODS FOR DIOXINS IN THE UNITED STATES
Because of the extensive cost, in personnel, time, equipment, and money to measure dioxin-like chemicals analytically, alternative technologies have been developed to measure the integrated sum of the activity of the dioxin-like chemicals.
DOT National Transportation Integrated Search
2001-09-25
This is the statement of Gerald L. Dillingham, Director, Physical Infrastructure Issues before the Committee on Governmental Affairs and Its Subcommittee on Oversight of Governmental Management, Restructuring and the District of Columbia, U.S. Senate...
78 FR 16694 - Chemical Security Assessment Tool (CSAT)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... information provided. Comments that include trade secrets, confidential commercial or financial information... secrets, confidential commercial or financial information, CVI, SSI, or PCII should be appropriately... Department make the instruments (e.g., Top-Screen, Security Vulnerability Assessment [SVA]/ Alternative...
Aviation security : vulnerabilities in, and alternatives for, preboard screening security operations
DOT National Transportation Integrated Search
2001-09-25
This is the statement of Gerald L. Dillingham, Director, Physical Infrastructure Issues before the Committee on Governmental Affairs and Its Subcommittee on Oversight of Governmental Management, Restructuring and the District of Columbia, U.S. Senate...
Terrain Display Alternatives Assessment of Information Density and Alerting Strategies
DOT National Transportation Integrated Search
1998-04-01
Current technology makes it possible to display navigation and terrain information on electronic : screens in the cockpit. The conventions used for position and terrain information must be clearly : presented so pilots can maintain their positional a...
Cost-effectiveness of prostate cancer screening: a simulation study based on ERSPC data.
Heijnsdijk, E A M; de Carvalho, T M; Auvinen, A; Zappa, M; Nelen, V; Kwiatkowski, M; Villers, A; Páez, A; Moss, S M; Tammela, T L J; Recker, F; Denis, L; Carlsson, S V; Wever, E M; Bangma, C H; Schröder, F H; Roobol, M J; Hugosson, J; de Koning, H J
2015-01-01
The results of the European Randomized Study of Screening for Prostate Cancer (ERSPC) trial showed a statistically significant 29% prostate cancer mortality reduction for the men screened in the intervention arm and a 23% negative impact on the life-years gained because of quality of life. However, alternative prostate-specific antigen (PSA) screening strategies for the population may exist, optimizing the effects on mortality reduction, quality of life, overdiagnosis, and costs. Based on data of the ERSPC trial, we predicted the numbers of prostate cancers diagnosed, prostate cancer deaths averted, life-years and quality-adjusted life-years (QALY) gained, and cost-effectiveness of 68 screening strategies starting at age 55 years, with a PSA threshold of 3, using microsimulation modeling. The screening strategies varied by age to stop screening and screening interval (one to 14 years or once in a lifetime screens), and therefore number of tests. Screening at short intervals of three years or less was more cost-effective than using longer intervals. Screening at ages 55 to 59 years with two-year intervals had an incremental cost-effectiveness ratio of $73000 per QALY gained and was considered optimal. With this strategy, lifetime prostate cancer mortality reduction was predicted as 13%, and 33% of the screen-detected cancers were overdiagnosed. When better quality of life for the post-treatment period could be achieved, an older age of 65 to 72 years for ending screening was obtained. Prostate cancer screening can be cost-effective when it is limited to two or three screens between ages 55 to 59 years. Screening above age 63 years is less cost-effective because of loss of QALYs because of overdiagnosis. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Onega, Tracy; Beaber, Elisabeth F; Sprague, Brian L; Barlow, William E; Haas, Jennifer S; Tosteson, Anna N A; D Schnall, Mitchell; Armstrong, Katrina; Schapira, Marilyn M; Geller, Berta; Weaver, Donald L; Conant, Emily F
2014-10-01
Breast cancer screening holds a prominent place in public health, health care delivery, policy, and women's health care decisions. Several factors are driving shifts in how population-based breast cancer screening is approached, including advanced imaging technologies, health system performance measures, health care reform, concern for "overdiagnosis," and improved understanding of risk. Maximizing benefits while minimizing the harms of screening requires moving from a "1-size-fits-all" guideline paradigm to more personalized strategies. A refined conceptual model for breast cancer screening is needed to align women's risks and preferences with screening regimens. A conceptual model of personalized breast cancer screening is presented herein that emphasizes key domains and transitions throughout the screening process, as well as multilevel perspectives. The key domains of screening awareness, detection, diagnosis, and treatment and survivorship are conceptualized to function at the level of the patient, provider, facility, health care system, and population/policy arena. Personalized breast cancer screening can be assessed across these domains with both process and outcome measures. Identifying, evaluating, and monitoring process measures in screening is a focus of a National Cancer Institute initiative entitled PROSPR (Population-based Research Optimizing Screening through Personalized Regimens), which will provide generalizable evidence for a risk-based model of breast cancer screening, The model presented builds on prior breast cancer screening models and may serve to identify new measures to optimize benefits-to-harms tradeoffs in population-based screening, which is a timely goal in the era of health care reform. © 2014 American Cancer Society.
NASA Astrophysics Data System (ADS)
Loring, B.; Karimabadi, H.; Rortershteyn, V.
2015-10-01
The surface line integral convolution(LIC) visualization technique produces dense visualization of vector fields on arbitrary surfaces. We present a screen space surface LIC algorithm for use in distributed memory data parallel sort last rendering infrastructures. The motivations for our work are to support analysis of datasets that are too large to fit in the main memory of a single computer and compatibility with prevalent parallel scientific visualization tools such as ParaView and VisIt. By working in screen space using OpenGL we can leverage the computational power of GPUs when they are available and run without them when they are not. We address efficiency and performance issues that arise from the transformation of data from physical to screen space by selecting an alternate screen space domain decomposition. We analyze the algorithm's scaling behavior with and without GPUs on two high performance computing systems using data from turbulent plasma simulations.
Early detection and management of pulmonary arterial hypertension.
Humbert, Marc; Gerry Coghlan, J; Khanna, Dinesh
2012-12-01
The long-term prognosis for patients with pulmonary arterial hypertension (PAH) remains poor, despite advances in treatment options that have been made in the past few decades. Recent evidence suggests that World Health Organization functional class I or II patients have significantly better long-term survival rates than patients in higher functional classes, thus providing a rationale for earlier diagnosis and treatment of PAH. However, early diagnosis is challenging and there is frequently a delay between symptom onset and diagnosis. Screening programmes play an important role in PAH detection and expert opinion favours echocardiographic screening of asymptomatic patients who may be predisposed to the development of PAH (i.e. those with systemic sclerosis or sickle cell disease), although current guidelines only recommend annual echocardiographic screening in symptomatic patients. This article reviews the currently available screening programmes, including their limitations, and describes alternative screening approaches that may identify more effectively those patients who require right heart catheterisation for a definitive PAH diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loring, Burlen; Karimabadi, Homa; Rortershteyn, Vadim
2014-07-01
The surface line integral convolution(LIC) visualization technique produces dense visualization of vector fields on arbitrary surfaces. We present a screen space surface LIC algorithm for use in distributed memory data parallel sort last rendering infrastructures. The motivations for our work are to support analysis of datasets that are too large to fit in the main memory of a single computer and compatibility with prevalent parallel scientific visualization tools such as ParaView and VisIt. By working in screen space using OpenGL we can leverage the computational power of GPUs when they are available and run without them when they are not.more » We address efficiency and performance issues that arise from the transformation of data from physical to screen space by selecting an alternate screen space domain decomposition. We analyze the algorithm's scaling behavior with and without GPUs on two high performance computing systems using data from turbulent plasma simulations.« less
Cost analysis of different cervical cancer screening strategies in Mexico.
Beal, Christyn M; Salmerón, Jorge; Flores, Yvonne N; Torres, Leticia; Granados-García, Víctor; Dugan, Ellen; Lazcano-Ponce, Eduardo
2014-01-01
To compare the costs and number of undetected cases of four cervical cancer screening strategies (CCSS) in Mexico. We estimated the costs and outcomes of the following CCSS: a) conventional Papanicolaou smear (Pap) alone; b) high-risk human papilloma virus testing (HR-HPV) as primary screening with Pap as reflex triage; c) HR-HPV as primary screening with HPV-16/18 typing, liquid-based cytology (LBC) and immunostaining for p16/Ki67 testing as reflex triage, and d) co-testing with HR-HPV and LBC with HPV-16/18 typing and immunostaining for p16/Ki67 as reflex triage. The outcome of interest was high-grade cervical lesions or cervical cancer. HR-HPV testing, HPV typing, LBC testing and immunostaining is the best alternative because it is the least expensive option with an acceptable number of missed cases. The opportunity costs of a poor quality CCSS is many false negatives. Combining multiple tests may be a more cost-effective way to screen for cervical cancer in Mexico.
Screening individual hybridomas by microengraving to discover monoclonal antibodies
Ogunniyi, Adebola O; Story, Craig M; Papa, Eliseo; Guillen, Eduardo; Love, J Christopher
2014-01-01
The demand for monoclonal antibodies (mAbs) in biomedical research is significant, but the current methodologies used to discover them are both lengthy and costly. Consequently, the diversity of antibodies available for any particular antigen remains limited. Microengraving is a soft lithographic technique that provides a rapid and efficient alternative for discovering new mAbs. This protocol describes how to use microengraving to screen mouse hybridomas to establish new cell lines producing unique mAbs. Single cells from a polyclonal population are isolated into an array of microscale wells (~105 cells per screen). The array is then used to print a protein microarray, where each element contains the antibodies captured from individual wells. The antibodies on the microarray are screened with antigens of interest, and mapped to the corresponding cells, which are then recovered from their microwells by micromanipulation. Screening and retrieval require approximately 1–3 d (9–12 d including the steps for preparing arrays of microwells). PMID:19528952
Selby-Harrington, M; Sorenson, J R; Quade, D; Stearns, S C; Tesh, A S; Donat, P L
1995-01-01
OBJECTIVES. A randomized controlled trial was conducted to test the effectiveness and cost effectiveness of three outreach interventions to promote well-child screening for children on Medicaid. METHODS. In rural North Carolina, a random sample of 2053 families with children due or overdue for screening was stratified according to the presence of a home phone. Families were randomly assigned to receive a mailed pamphlet and letter, a phone call, or a home visit outreach intervention, or the usual (control) method of informing at Medicaid intake. RESULTS. All interventions produced more screenings than the control method, but increases were significant only for families with phones. Among families with phones, a home visit was the most effective intervention but a phone call was the most cost-effective. However, absolute rates of effectiveness were low, and incremental costs per effect were high. CONCLUSIONS. Pamphlets, phone calls, and home visits by nurses were minimally effective for increasing well-child screenings. Alternate outreach methods are needed, especially for families without phones. PMID:7573627
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sig Drellack, Lance Prothro
2007-12-01
The Underground Test Area (UGTA) Project of the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is in the process of assessing and developing regulatory decision options based on modeling predictions of contaminant transport from underground testing of nuclear weapons at the Nevada Test Site (NTS). The UGTA Project is attempting to develop an effective modeling strategy that addresses and quantifies multiple components of uncertainty including natural variability, parameter uncertainty, conceptual/model uncertainty, and decision uncertainty in translating model results into regulatory requirements. The modeling task presents multiple unique challenges to the hydrological sciences as a result ofmore » the complex fractured and faulted hydrostratigraphy, the distributed locations of sources, the suite of reactive and non-reactive radionuclides, and uncertainty in conceptual models. Characterization of the hydrogeologic system is difficult and expensive because of deep groundwater in the arid desert setting and the large spatial setting of the NTS. Therefore, conceptual model uncertainty is partially addressed through the development of multiple alternative conceptual models of the hydrostratigraphic framework and multiple alternative models of recharge and discharge. Uncertainty in boundary conditions is assessed through development of alternative groundwater fluxes through multiple simulations using the regional groundwater flow model. Calibration of alternative models to heads and measured or inferred fluxes has not proven to provide clear measures of model quality. Therefore, model screening by comparison to independently-derived natural geochemical mixing targets through cluster analysis has also been invoked to evaluate differences between alternative conceptual models. Advancing multiple alternative flow models, sensitivity of transport predictions to parameter uncertainty is assessed through Monte Carlo simulations. The simulations are challenged by the distributed sources in each of the Corrective Action Units, by complex mass transfer processes, and by the size and complexity of the field-scale flow models. An efficient methodology utilizing particle tracking results and convolution integrals provides in situ concentrations appropriate for Monte Carlo analysis. Uncertainty in source releases and transport parameters including effective porosity, fracture apertures and spacing, matrix diffusion coefficients, sorption coefficients, and colloid load and mobility are considered. With the distributions of input uncertainties and output plume volumes, global analysis methods including stepwise regression, contingency table analysis, and classification tree analysis are used to develop sensitivity rankings of parameter uncertainties for each model considered, thus assisting a variety of decisions.« less
Screening for EIA in India: enhancing effectiveness through ecological carrying capacity approach.
Rajaram, T; Das, Ashutosh
2011-01-01
Developing countries across the world have embraced the policy of high economic growth as a means to reduce poverty. This economic growth largely based on industrial output is fast degrading the ecosystems, jeopardizing their long term sustainability. Environmental Impact Assessment (EIA) has long been recognized as a tool which can help in protecting the ecosystems and aid sustainable development. The Screening guidelines for EIA reflect the level of commitment the nation displays towards tightening its environmental protection system. The paper analyses the screening process for EIA in India and dissects the rationale behind the exclusions and thresholds set in the screening process. The screening process in India is compared with that of the European Union with the aim of understanding the extent of deviations from a screening approach in the context of better economic development. It is found that the Indian system excludes many activities from the purview of screening itself when compared to the EU. The constraints responsible for these exclusions are discussed and the shortcomings of the current command and control system of environmental management in India are also explained. It is suggested that an ecosystem carrying capacity based management system can provide significant inputs to enhance the effectiveness of EIA process from screening to monitoring. Copyright © 2010 Elsevier Ltd. All rights reserved.
Wall, Ivan B.; Peake, Matthew; Kipling, David; Giles, Peter; Thomas, David W.
2018-01-01
Background: Chronic skin wounds are a growing financial burden for healthcare providers, causing discomfort/immobility to patients. Whilst animal chronic wound models have been developed to allow for mechanistic studies and to develop/test potential therapies, such systems are not good representations of the human chronic wound state. As an alternative, human chronic wound fibroblasts (CWFs) have permitted an insight into the dysfunctional cellular mechanisms that are associated with these wounds. However, such cells strains have a limited replicative lifespan and therefore a limited reproducibility/usefulness. Objectives: To develop/characterise immortalised cell lines of CWF and patient-matched normal fibroblasts (NFs). Methods and Results: Immortalisation with human telomerase resulted in both CWF and NF proliferating well beyond their replicative senescence end-point (respective cell strains senesced as normal). Gene expression analysis demonstrated that, whilst proliferation-associated genes were up-regulated in the cell lines (as would be expected), the immortalisation process did not significantly affect the disease-specific genotype. Immortalised CWF (as compared to NF) also retained a distinct impairment in their wound repopulation potential (in line with CWF cell strains). Conclusions: These novel CWF cell lines are a credible animal alternative and could be a valuable research tool for understanding both the aetiology of chronic skin wounds and for therapeutic pre-screening. PMID:29584680
Vreugdenburg, Thomas D; Laurence, Caroline O; Willis, Cameron D; Mundy, Linda; Hiller, Janet E
2014-09-01
To describe the nature and frequency of information presented on direct-to-consumer websites for emerging breast cancer imaging devices. Content analysis of Australian website advertisements from 2 March 2011 to 30 March 2012, for three emerging breast cancer imaging devices: digital infrared thermal imaging, electrical impedance scanning and electronic palpation imaging. Type of imaging offered, device safety, device performance, application of device, target population, supporting evidence and comparator tests. Thirty-nine unique Australian websites promoting a direct-to-consumer breast imaging device were identified. Despite a lack of supporting evidence, 22 websites advertised devices for diagnosis, 20 advertised devices for screening, 13 advertised devices for prevention and 13 advertised devices for identifying breast cancer risk factors. Similarly, advertised ranges of diagnostic sensitivity (78%-99%) and specificity (44%-91%) were relatively high compared with published literature. Direct comparisons with conventional screening tools that favoured the new device were highly prominent (31 websites), and one-third of websites (12) explicitly promoted their device as a suitable alternative. Australian websites for emerging breast imaging devices, which are also available internationally, promote the use of such devices as safe and effective solutions for breast cancer screening and diagnosis in a range of target populations. Many of these claims are not supported by peer-reviewed evidence, raising questions about the manner in which these devices and their advertising material are regulated, particularly when they are promoted as direct alternatives to established screening interventions.
Sharaf, Ravi N; Ladabaum, Uri
2013-01-01
Fecal occult blood testing (FOBT) and sigmoidoscopy are proven to decrease colorectal cancer (CRC) incidence and mortality. Sigmoidoscopy's benefit is limited to the distal colon. Observational data are conflicting regarding the degree to which colonoscopy affords protection against proximal CRC. Our aim was to explore the comparative effectiveness and cost-effectiveness of colonoscopy vs. sigmoidoscopy and alternative CRC screening strategies in light of the latest published data. We performed a contemporary cost-utility analysis using a Markov model validated against data from randomized controlled trials of FOBT and sigmoidoscopy. Persons at average CRC risk within the general US population were modeled. Screening strategies included those recommended by the United States (US) Preventive Services Task Force, including colonoscopy every 10 years (COLO), flexible sigmoidoscopy every 5 years (FS), annual fecal occult blood testing, annual fecal immunochemical testing (FIT), and the combination FS/FIT. The main outcome measures were quality-adjusted life-years (QALYs) and costs. In the base case, FIT dominated other strategies. The advantage of FIT over FS and COLO was contingent on rates of uptake and adherence that are well above current US rates. Compared with FIT, FS and COLO both cost <$50,000/QALY gained when FIT per-cycle adherence was <50%. COLO cost $56,800/QALY gained vs. FS in the base case. COLO cost <$100,000/QALY gained vs. FS when COLO yielded a relative risk of proximal CRC of <0.5 vs. no screening. In probabilistic analyses, COLO was cost-effective vs. FS at a willingness-to-pay threshold of $100,000/QALY gained in 84% of iterations. Screening colonoscopy may be cost-effective compared with FIT and sigmoidoscopy, depending on the relative rates of screening uptake and adherence and the protective benefit of colonoscopy in the proximal colon. Colonoscopy's cost-effectiveness compared with sigmoidoscopy is contingent on the ability to deliver ~50% protection against CRC in the proximal colon.
Freshwater Planarians as an Alternative Animal Model for Neurotoxicology.
Hagstrom, Danielle; Cochet-Escartin, Olivier; Zhang, Siqi; Khuu, Cindy; Collins, Eva-Maria S
2015-09-01
Traditional toxicology testing has relied on low-throughput, expensive mammalian studies; however, timely testing of the large number of environmental toxicants requires new in vitro and in vivo platforms for inexpensive medium- to high-throughput screening. Herein, we describe the suitability of the asexual freshwater planarian Dugesia japonica as a new animal model for the study of developmental neurotoxicology. As these asexual animals reproduce by binary fission, followed by regeneration of missing body structures within approximately 1 week, development and regeneration occur through similar processes allowing us to induce neurodevelopment "at will" through amputation. This short time scale and the comparable sizes of full and regenerating animals enable parallel experiments in adults and developing worms to determine development-specific aspects of toxicity. Because the planarian brain, despite its simplicity, is structurally and molecularly similar to the mammalian brain, we are able to ascertain neurodevelopmental toxicity that is relevant to humans. As a proof of concept, we developed a 5-step semiautomatic screening platform to characterize the toxicity of 9 known neurotoxicants (consisting of common solvents, pesticides, and detergents) and a neutral agent, glucose, and quantified effects on viability, stimulated and unstimulated behavior, regeneration, and brain structure. Comparisons of our findings with other alternative toxicology animal models, such as zebrafish larvae and nematodes, demonstrated that planarians are comparably sensitive to the tested chemicals. In addition, we found that certain compounds induced adverse effects specifically in developing animals. We thus conclude that planarians offer new complementary opportunities for developmental neurotoxicology animal models. © The Author 2015. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Securing recruitment and obtaining informed consent in minority ethnic groups in the UK.
Lloyd, Cathy E; Johnson, Mark R D; Mughal, Shanaz; Sturt, Jackie A; Collins, Gary S; Roy, Tapash; Bibi, Rukhsana; Barnett, Anthony H
2008-03-30
Previous health research has often explicitly excluded individuals from minority ethnic backgrounds due to perceived cultural and communication difficulties, including studies where there might be language/literacy problems in obtaining informed consent. This study addressed these difficulties by developing audio-recorded methods of obtaining informed consent and recording data. This report outlines 1) our experiences with securing recruitment to a qualitative study investigating alternative methods of data collection, and 2) the development of a standardised process for obtaining informed consent from individuals from minority ethnic backgrounds whose main language does not have an agreed written form. Two researchers from South Asian backgrounds recruited adults with Type 2 diabetes whose main language was spoken and not written, to attend a series of focus groups. A screening tool was used at recruitment in order to assess literacy skills in potential participants. Informed consent was obtained using audio-recordings of the patient information and recording patients' verbal consent. Participants' perceptions of this method of obtaining consent were recorded. Recruitment rates were improved by using telephone compared to face-to-face methods. The screening tool was found to be acceptable by all potential participants. Audio-recorded methods of obtaining informed consent were easy to implement and accepted by all participants. Attrition rates differed according to ethnic group. Snowballing techniques only partly improved participation rates. Audio-recorded methods of obtaining informed consent are an acceptable alternative to written consent in study populations where literacy skills are variable. Further exploration of issues relating to attrition is required, and a range of methods may be necessary in order to maximise response and participation rates.
In vitro immunomodulatory activity of plants used by the Tacana ethnic group in Bolivia.
Deharo, E; Baelmans, R; Gimenez, A; Quenevo, C; Bourdy, G
2004-09-01
One hundred and seventy-eight ethanolic plant extracts from the pharmacopoeia of the Tacana, an ethnic group from Bolivia, were screened for immunomodulatory activity using complement cascade inhibition and ADP-induced platelet aggregation inhibition assays. Six impaired both complement pathways (classical and alternative): stem bark from Astronium urundeuvea (Anacardiaceae), Cochlospermum vitifolium (Cochlospermaceae), Terminalia amazonica (Combretaceae), Triplaris americana (Polygonaceae), Uncaria tomentosa (Rubiaceae) and Euterpe precatoria (Arecaceae) roots. Inhibition of complement cascade was independent of essential ion complexation, and was not due to direct hemolytic activity on target red blood cells. For A. urundeuvea, C. vitifolium, and T. amazonica, anti-inflammatory activity relied on cyclo-oxygenase inhibition. Four of these species (A. urundeuva, T. americana, U. tomentosa and E. precatoria) are used traditionally to treat inflammatory processes.
Johnson, L; Harrison, J H; Hunt, C; Shinners, K; Doggett, C G; Sapienza, D
1999-12-01
Stage of maturity at harvest and mechanical processing affect the nutritive value of corn silage. The change in nutritive value of corn silage as maturity advances can be measured by animal digestion and macro in situ degradation studies among other methods. Predictive equations using climatic data, vitreousness of corn grain in corn silage, starch reactivity, gelatinization enthalpy, dry matter (DM) of corn grain in corn silage, and DM of corn silage can be used to estimate starch digestibility of corn silage. Whole plant corn silage can be mechanically processed either pre- or postensiling with a kernel processor mounted on a forage harvester, a recutter screen on a forage harvester, or a stationary roller mill. Mechanical processing of corn silage can improve ensiling characteristics, reduce DM losses during ensiling, and improve starch and fiber digestion as a result of fracturing the corn kernels and crushing and shearing the stover and cobs. Improvements in milk production have ranged from 0.2 to 2.0 kg/d when cows were fed mechanically processed corn silage. A consistent improvement in milk protein yield has also been observed when mechanically processed corn silage has been fed. With the advent of mechanical processors, alternative strategies are evident for corn silage management, such as a longer harvest window.
Hausleiter, Jörg; Braun, Daniel; Orban, Mathias; Latib, Azeem; Lurz, Philipp; Boekstegers, Peter; von Bardeleben, Ralph Stephan; Kowalski, Marek; Hahn, Rebecca T; Maisano, Francesco; Hagl, Christian; Massberg, Steffen; Nabauer, Michael
2018-04-24
Severe tricuspid regurgitation (TR) has long been neglected despite its well known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though the device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and variability of tricuspid valve anatomy, echocardiographic visibility of the valve leaflets, and device steering to the tricuspid valve. Furthermore, it remains to be clarified which patients are suitable for a percutaneous tricuspid repair and which features predict a successful procedure. On the basis of the available experience, we describe criteria for patient selection including morphological valve features, a standardized process for echocardiographic screening, and a strategy for clip placement. These criteria will help to achieve standardization of valve assessment and the procedural approach, and to further develop interventional tricuspid valve repair using either currently available devices or dedicated tricuspid edge-to-edge repair devices in the future. In summary, this manuscript will provide guidance for patient selection and echocardiographic screening when considering edge-to-edge repair for severe TR.
Andrykowski, Michael A.; Pavlik, Edward J.
2009-01-01
All cancer screening tests produce a proportion of abnormal results requiring follow-up. Consequently, the cancer screening setting is a natural laboratory for examining psychological and behavioral response to a threatening health-related event. This study tested hypotheses derived from the Social Cognitive Processing and Cognitive-Social Health Information Processing models in trying to understand response to an abnormal ovarian cancer (OC) screening test result. Women (n=278) receiving an abnormal screening test result a mean of 7 weeks earlier were assessed prior to a repeat screening test intended to clarify their previous abnormal result. Measures of disposition (optimism, informational coping style), social environment (social support and constraint), emotional processing, distress, and benefit finding were obtained. Regression analyses indicated greater distress was associated with greater social constraint and emotional processing and a monitoring coping style in women with a family history of OC. Distress was unrelated to social support. Greater benefit finding was associated with both greater social constraint and support and greater distress. The primacy of social constraint in accounting for both benefit-finding and distress was noteworthy and warrants further research on the role of social constraint in adaptation to stressful events. PMID:20419561
Chou, Roger; Dana, Tracy; Blazina, Ian; Daeges, Monica; Bougatsos, Christina; Jeanne, Thomas L
2016-10-18
Dyslipidemia may occur in younger adults (defined as persons aged 21 to 39 years) and is an important risk factor for cardiovascular disease. Screening might identify younger adults with asymptomatic dyslipidemia who may benefit from lipid-lowering therapies. To update the 2008 U.S. Preventive Services Task Force review on dyslipidemia screening in younger adults. The Cochrane Central Register of Controlled Trials, the Cochrane Database of Systematic Reviews, and MEDLINE through May 2016, and reference lists. Randomized, controlled trials; cohort studies; and case-control studies on screening for or treatment of asymptomatic dyslipidemia in adults aged 21 to 39 years. The plan was for 1 investigator to abstract data and a second to check their accuracy, and for 2 investigators to independently assess study quality; however, no studies met the inclusion criteria. No study evaluated the effects of lipid screening versus no screening, treatment versus no treatment, or delayed versus earlier treatment on clinical outcomes in younger adults. In addition, no study evaluated the diagnostic yield of alternative screening strategies (such as targeted screening of persons with a family history of hyperlipidemia vs. general screening) in younger adults. No direct relevant evidence. Direct evidence on the benefits and harms of screening for or treatment of dyslipidemia in younger adults remains unavailable. Estimating the potential effects of screening for dyslipidemia in this population requires extrapolation from studies performed in older adults. Agency for Healthcare Research and Quality.
van Rossum, Leo G M; van Rijn, Anne F; Verbeek, Andre L M; van Oijen, Martijn G H; Laheij, Robert J F; Fockens, Paul; Jansen, Jan B M J; Adang, Eddy M M; Dekker, Evelien
2011-04-15
Comparability of cost-effectiveness of colorectal cancer (CRC) screening strategies is limited if heterogeneous study data are combined. We analyzed prospective empirical data from a randomized-controlled trial to compare cost-effectiveness of screening with either one round of immunochemical fecal occult blood testing (I-FOBT; OC-Sensor®), one round of guaiac FOBT (G-FOBT; Hemoccult-II®) or no screening in Dutch aged 50 to 75 years, completed with cancer registry and literature data, from a third-party payer perspective in a Markov model with first- and second-order Monte Carlo simulation. Costs were measured in Euros (€), effects in life-years gained, and both were discounted with 3%. Uncertainty surrounding important parameters was analyzed. I-FOBT dominated the alternatives: after one round of I-FOBT screening, a hypothetical person would on average gain 0.003 life-years and save the health care system €27 compared with G-FOBT and 0.003 life years and €72 compared with no screening. Overall, in 4,460,265 Dutch aged 50-75 years, after one round I-FOBT screening, 13,400 life-years and €320 million would have been saved compared with no screening. I-FOBT also dominated in sensitivity analyses, varying uncertainty surrounding important effect and cost parameters. CRC screening with I-FOBT dominated G-FOBT and no screening with or without accounting for uncertainty. Copyright © 2010 UICC.
Retinopathy of prematurity: the high cost of screening regional and remote infants.
Yu, Tzu-Ying; Donovan, Tim; Armfield, Nigel; Gole, Glen A
2018-01-25
Demand for retinopathy of prematurity (ROP) screening is increasing for infants born at rural and regional hospitals where the service is not generally available. The health system cost for screening regional/remote infants has not been reported. The objective of this study is to evaluate the cost of ROP screening at a large centralized tertiary neonatal service for infants from regional/rural hospitals. This is a retrospective study to establish the cost of transferring regional/rural infants to the Royal Brisbane and Women's Hospital for ROP screening over a 28-month period. A total of 131 infants were included in this study. Individual infant costs were calculated from analysis of clinical and administrative records. Economic cost of ROP screening for all transfers from regional/rural hospitals to Royal Brisbane and Women's Hospital. The average economic cost of ROP screening for this cohort was AUD$5110 per infant screened and the total cost was AUD$669 413. The average cost per infant screened was highest for infants from a regional centre with a population of 75 000 (AUD$14 856 per child), which was also geographically furthest from Brisbane. No infant in this cohort transferred from a regional nursery reached criteria for intervention for ROP by standard guidelines. Health system costs for ROP screening of remote infants at a centralized hospital are high. Alternative strategies using telemedicine can now be compared with centralized screening. © 2018 Royal Australian and New Zealand College of Ophthalmologists.
Consumer preferences for teledermoscopy screening to detect melanoma early.
Spinks, Jean; Janda, Monika; Soyer, H Peter; Whitty, Jennifer A
2016-01-01
'Store and forward' teledermoscopy is a technology with potential advantages for melanoma screening. Any large-scale implementation of this technology is dependent on consumer acceptance. To investigate preferences for melanoma screening options compared with skin self-examination in adults considered to be at increased risk of developing skin cancer. A discrete choice experiment was completed by 35 consumers, all of whom had prior experience with the use of teledermoscopy, in Queensland, Australia. Participants made 12 choices between screening alternatives described by seven attributes including monetary cost. A mixed logit model was used to estimate the relative weights that consumers place on different aspects of screening, along with the marginal willingness to pay for teledermoscopy as opposed to screening at a clinic. Overall, participants preferred screening/diagnosis by a health professional rather than skin self-examination. Key drivers of screening choice were for results to be reviewed by a dermatologist; a higher detection rate; fewer non-cancerous moles being removed in relation to every skin cancer detected; and less time spent away from usual activities. On average, participants were willing to pay AUD110 to have teledermoscopy with dermatologist review available to them as a screening option. Consumers preferentially value aspects of care that are more feasible with a teledermoscopy screening model, as compared with other skin cancer screening and diagnosis options. This study adds to previous literature in the area which has relied on the use of consumer satisfaction scales to assess the acceptability of teledermoscopy. © The Author(s) 2015.
Kittelmann, Jörg; Ottens, Marcel; Hubbuch, Jürgen
2015-04-15
High-throughput batch screening technologies have become an important tool in downstream process development. Although continuative miniaturization saves time and sample consumption, there is yet no screening process described in the 384-well microplate format. Several processes are established in the 96-well dimension to investigate protein-adsorbent interactions, utilizing between 6.8 and 50 μL resin per well. However, as sample consumption scales with resin volumes and throughput scales with experiments per microplate, they are limited in costs and saved time. In this work, a new method for in-well resin quantification by optical means, applicable in the 384-well format, and resin volumes as small as 0.1 μL is introduced. A HTS batch isotherm process is described, utilizing this new method in combination with optical sample volume quantification for screening of isotherm parameters in 384-well microplates. Results are qualified by confidence bounds determined by bootstrap analysis and a comprehensive Monte Carlo study of error propagation. This new approach opens the door to a variety of screening processes in the 384-well format on HTS stations, higher quality screening data and an increase in throughput. Copyright © 2015 Elsevier B.V. All rights reserved.
One-week 96-well soft agar growth assay for cancer target validation.
Ke, Ning; Albers, Aaron; Claassen, Gisela; Yu, De-hua; Chatterton, Jon E; Hu, Xiuyuan; Meyhack, Bernd; Wong-Staal, Flossie; Li, Qi-Xiang
2004-05-01
Soft agar growth, used to measure cell anchorage-independent proliferation potential, is one of the most important and most commonly used assays to detect cell transformation. However, the traditional soft agar assay is time-consuming, labor-intensive, and plagued with inconsistencies due to individual subjectivity. It does not, therefore, meet the increasing demands of today's oncology drug target screening or validation processes. This report describes an alternative 96-well soft agar growth assay that can function as a replacement for the traditional method and overcomes the aforementioned limitations. It offers the following advantages: a shortened assay duration (1 week instead of 4 weeks) that makes transient transfection or treatment possible; plate reader quantification of soft agar growth (measuring cloning efficiency and colony size); and a significant reduction in required labor. Higher throughput also makes it possible to process large numbers of samples and treatments simultaneously and in a much more efficient manner, while saving precious workspace and overall cost.
Lateral instability of high temperature pipelines, the 20-in. Sleipner Vest pipeline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saevik, S.; Levold, E.; Johnsen, O.K.
1996-12-01
The present paper addresses methods to control snaking behavior of high temperature pipelines resting on a flat sea bed. A case study is presented based on the detail engineering of the 12.5 km long 20 inch gas pipeline connecting the Sleipner Vest wellhead platform to the Sleipner T processing platform in the North Sea. The study includes screening and evaluation of alternative expansion control methods, ending up with a recommended method. The methodology and philosophy, used as basis to ensure sufficient structural strength throughout the lifetime of the pipeline, are thereafter presented. The results show that in order to findmore » the optimum technical solution to control snaking behavior, many aspects need to be considered such as process requirements, allowable strain, hydrodynamic stability, vertical profile, pipelay installation and trawlboard loading. It is concluded that by proper consideration of all the above aspects, the high temperature pipeline can be designed to obtain sufficient safety level.« less
Visual screening for malignant melanoma: a cost-effectiveness analysis.
Losina, Elena; Walensky, Rochelle P; Geller, Alan; Beddingfield, Frederick C; Wolf, Lindsey L; Gilchrest, Barbara A; Freedberg, Kenneth A
2007-01-01
To evaluate the cost-effectiveness of various melanoma screening strategies proposed in the United States. We developed a computer simulation Markov model to evaluate alternative melanoma screening strategies. Hypothetical cohort of the general population and siblings of patients with melanoma. Intervention We considered the following 4 strategies: background screening only, and screening 1 time, every 2 years, and annually, all beginning at age 50 years. Prevalence, incidence, and mortality data were taken from the Surveillance, Epidemiology, and End Results Program. Sibling risk, recurrence rates, and treatment costs were taken from the literature. Outcomes included life expectancy, quality-adjusted life expectancy, and lifetime costs. Cost-effectiveness ratios were in dollars per quality-adjusted life year (US dollars/QALY) gained. In the general population, screening 1 time, every 2 years, and annually saved 1.6, 4.4, and 5.2 QALYs per 1000 persons screened, with incremental cost-effectiveness ratios of US dollars 10,100/QALY, US dollars 80,700/QALY, and US dollars 586,800/QALY, respectively. In siblings of patients with melanoma (relative risk, 2.24 compared with the general population), 1-time, every-2-years, and annual screenings saved 3.6, 9.8, and 11.4 QALYs per 1000 persons screened, with incremental cost-effectiveness ratios of US dollars 4000/QALY, US dollars 35,500/QALY, and US dollars 257,800/QALY, respectively. In higher risk siblings of patients with melanoma (relative risk, 5.56), screening was more cost-effective. Results were most sensitive to screening cost, melanoma progression rate, and specificity of visual screening. One-time melanoma screening of the general population older than 50 years is very cost-effective compared with other cancer screening programs in the United States. Screening every 2 years in siblings of patients with melanoma is also cost-effective.
NASA Astrophysics Data System (ADS)
Swartz, Charles S.
2003-05-01
The process of distributing and exhibiting a motion picture has changed little since the Lumière brothers presented the first motion picture to an audience in 1895. While this analog photochemical process is capable of producing screen images of great beauty and expressive power, more often the consumer experience is diminished by third generation prints and by the wear and tear of the mechanical process. Furthermore, the film industry globally spends approximately $1B annually manufacturing and shipping prints. Alternatively, distributing digital files would theoretically yield great benefits in terms of image clarity and quality, lower cost, greater security, and more flexibility in the cinema (e.g., multiple language versions). In order to understand the components of the digital cinema chain and evaluate the proposed technical solutions, the Entertainment Technology Center at USC in 2000 established the Digital Cinema Laboratory as a critical viewing environment, with the highest quality film and digital projection equipment. The presentation describes the infrastructure of the Lab, test materials, and testing methodologies developed for compression evaluation, and lessons learned up to the present. In addition to compression, the Digital Cinema Laboratory plans to evaluate other components of the digital cinema process as well.
Performance Assessment Uncertainty Analysis for Japan's HLW Program Feasibility Study (H12)
DOE Office of Scientific and Technical Information (OSTI.GOV)
BABA,T.; ISHIGURO,K.; ISHIHARA,Y.
1999-08-30
Most HLW programs in the world recognize that any estimate of long-term radiological performance must be couched in terms of the uncertainties derived from natural variation, changes through time and lack of knowledge about the essential processes. The Japan Nuclear Cycle Development Institute followed a relatively standard procedure to address two major categories of uncertainty. First, a FEatures, Events and Processes (FEPs) listing, screening and grouping activity was pursued in order to define the range of uncertainty in system processes as well as possible variations in engineering design. A reference and many alternative cases representing various groups of FEPs weremore » defined and individual numerical simulations performed for each to quantify the range of conceptual uncertainty. Second, parameter distributions were developed for the reference case to represent the uncertainty in the strength of these processes, the sequencing of activities and geometric variations. Both point estimates using high and low values for individual parameters as well as a probabilistic analysis were performed to estimate parameter uncertainty. A brief description of the conceptual model uncertainty analysis is presented. This paper focuses on presenting the details of the probabilistic parameter uncertainty assessment.« less
Healthy participants in phase I clinical trials: the quality of their decision to take part.
Rabin, Cheryl; Tabak, Nili
2006-08-01
This study was set out to test the quality of the decision-making process of healthy volunteers in clinical trials. Researchers fear that the decision to volunteer for clinical trials is taken inadequately and that the signature on the consent forms, meant to affirm that consent was 'informed', is actually insubstantial. The study design was quasi-experimental, using a convenience quota sample. Over a period of a year, candidates were approached during their screening process for a proposed clinical trial, after concluding the required 'Informed Consent' procedure. In all, 100 participants in phase I trials filled out questionnaires based ultimately on the Janis and Mann model of vigilant information processing, during their stay in the research centre. Only 35% of the participants reached a 'quality decision'. There is a definite correlation between information processing and quality decision-making. However, many of the healthy research volunteers (58%) do not seek out information nor check alternatives before making a decision. Full disclosure is essential to a valid informed consent procedure but not sufficient; emphasis must be put on having the information understood and assimilated. Research nurses play a central role in achieving this objective.
Smart Screening System (S3) In Taconite Processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daryoush Allaei; Angus Morison; David Tarnowski
2005-09-01
The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supportingmore » structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key components include smart motor and associated electronics, resonators, and supporting structural elements. It is shown that the smart motors have an acceptable life and performance. Resonator (or motion amplifier) designs are selected based on the final system requirement and vibration characteristics. All the components for a fully functional prototype are fabricated. The development program is on schedule. The last semi-annual report described the process of FE model validation and correlation with experimental data in terms of dynamic performance and predicted stresses. It also detailed efforts into making the supporting structure less important to system performance. Finally, an introduction into the dry application concept was presented. Since then, the design refinement phase was completed. This has resulted in a Smart Screen design that meets performance targets both in the dry condition and with taconite slurry flow using PZT motors. Furthermore, this system was successfully demonstrated for the DOE and partner companies at the Coleraine Mineral Research Laboratory in Coleraine, Minnesota.« less
High-Throughput Screening in ToxCast/Tox21 (FutureToxII)
Addressing safety aspects of drugs and environmental chemicals relies extensively on animal testing. However, the quantity of chemicals needing assessment and challenges of species extrapolation require development of alternative approaches. The EPA’s ToxCast program addresses th...
Screening candidate water quality indicators for associations with swimming-related illness
ABSTRACT Traditional (culture-based) indicator organisms (e.g. enterococci, fecal and total coliforms) are used to regulate marine beaches for protecting human health. Despite the recent proliferation of new technology, few studies have examined alternatives to this decades...
ABSTRACT BODY: Thousands of chemicals lack adequate testing for adverse effects on nervous system development, stimulating research into alternative methods to screen chemicals for potential developmental neurotoxicity. Microelectrode arrays (MEA) collect action potential spiking...
Code of Federal Regulations, 2010 CFR
2010-10-01
... following risk categories: (i) Has a family history of an abdominal aortic aneurysm. (ii) Is a man age 65 to...: (1) A procedure using soundwaves (or other procedures using alternative technologies of commensurate...
Zebrafish Development: High-throughput Test Systems to Assess Developmental Toxicity
Abstract Because of its developmental concordance, ease of handling and rapid development, the small teleost, zebrafish (Danio rerio), is frequently promoted as a vertebrate model for medium-throughput developmental screens. This present chapter discusses zebrafish as an altern...
Leis, Benedikt; Angelov, Angel; Mientus, Markus; Li, Haijuan; Pham, Vu T T; Lauinger, Benjamin; Bongen, Patrick; Pietruszka, Jörg; Gonçalves, Luís G; Santos, Helena; Liebl, Wolfgang
2015-01-01
Functional metagenomic screening strategies, which are independent of known sequence information, can lead to the identification of truly novel genes and enzymes. Since E. coli has been used exhaustively for this purpose as a host, it is important to establish alternative expression hosts and to use them for functional metagenomic screening for new enzymes. In this study we show that Thermus thermophilus HB27 is an excellent screening host and can be used as an alternative provider of truly novel biocatalysts. In a previous study we constructed mutant strain BL03 with multiple markerless deletions in genes for major extra- and intracellular lipolytic activities. This esterase-diminished strain was no longer able to grow on defined minimal medium supplemented with tributyrin as the sole carbon source and could be used as a host to screen for metagenomic DNA fragments that could complement growth on tributyrin. Several thousand single fosmid clones from thermophilic metagenomic libraries from heated compost and hot spring water samples were subjected to a comparative screening for esterase activity in both T. thermophilus strain BL03 and E. coli EPI300. We scored a greater number of active esterase clones in the thermophilic bacterium than in the mesophilic E. coli. From several thousand functionally screened clones only two thermostable α/β-fold hydrolase enzymes with high amino acid sequence similarity to already characterized enzymes were identifiable in E. coli. In contrast, five further fosmids were found that conferred lipolytic activities in T. thermophilus only. Four open reading frames (ORFs) were found which did not share significant similarity to known esterase enzymes but contained the conserved GXSXG motif regularly found in lipolytic enzymes. Two of the genes were expressed in both hosts and the novel thermophilic esterases, which based on their primary structures could not be assigned to known esterase or lipase families, were purified and preliminarily characterized. Our work underscores the benefit of using additional screening hosts other than E. coli for the identification of novel biocatalysts with industrial relevance.
Smart Screening System (S3) In Taconite Processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daryoush Allaei; Ryan Wartman; David Tarnowski
2006-03-01
The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supportingmore » structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key components include smart motor and associated electronics, resonators, and supporting structural elements. It is shown that the smart motors have an acceptable life and performance. Resonator (or motion amplifier) designs are selected based on the final system requirement and vibration characteristics. All the components for a fully functional prototype are fabricated. The development program is on schedule. The last semi-annual report described the completion of the design refinement phase. This phase resulted in a Smart Screen design that meets performance targets both in the dry condition and with taconite slurry flow using PZT motors. This system was successfully demonstrated for the DOE and partner companies at the Coleraine Mineral Research Laboratory in Coleraine, Minnesota. Since then, the fabrication of the dry application prototype (incorporating an electromagnetic drive mechanism and a new deblinding concept) has been completed and successfully tested at QRDC's lab.« less
Screening of chemical compound libraries identified new anti-Toxoplasma gondii agents.
Adeyemi, Oluyomi Stephen; Sugi, Tatsuki; Han, Yongmei; Kato, Kentaro
2018-02-01
Toxoplasma gondii is the etiological agent of toxoplasmosis, a common parasitic disease that affects nearly one-third of the human population. The primary infection can be asymptomatic in healthy individuals but may prove fatal in immunocompromised individuals. Available treatment options for toxoplasmosis patients are limited, underscoring the urgent need to identify and develop new therapies. Non-biased screening of libraries of chemical compounds including the repurposing of well-characterized compounds is emerging as viable approach to achieving this goal. In the present investigation, we screened libraries of natural product and FDA-approved compounds to identify those that inhibited T. gondii growth. We identified 32 new compounds that potently inhibit T. gondii growth. Our findings are new and promising, and further strengthen the prospects of drug repurposing as well as the screening of a wide range of chemical compounds as a viable source of alternative anti-parasitic therapeutic agents.
Model dielectric function for 2D semiconductors including substrate screening
NASA Astrophysics Data System (ADS)
Trolle, Mads L.; Pedersen, Thomas G.; Véniard, Valerie
2017-01-01
Dielectric screening of excitons in 2D semiconductors is known to be a highly non-local effect, which in reciprocal space translates to a strong dependence on momentum transfer q. We present an analytical model dielectric function, including the full non-linear q-dependency, which may be used as an alternative to more numerically taxing ab initio screening functions. By verifying the good agreement between excitonic optical properties calculated using our model dielectric function, and those derived from ab initio methods, we demonstrate the versatility of this approach. Our test systems include: Monolayer hBN, monolayer MoS2, and the surface exciton of a 2 × 1 reconstructed Si(111) surface. Additionally, using our model, we easily take substrate screening effects into account. Hence, we include also a systematic study of the effects of substrate media on the excitonic optical properties of MoS2 and hBN.
Postgenomic strategies in antibacterial drug discovery.
Brötz-Oesterhelt, Heike; Sass, Peter
2010-10-01
During the last decade the field of antibacterial drug discovery has changed in many aspects including bacterial organisms of primary interest, discovery strategies applied and pharmaceutical companies involved. Target-based high-throughput screening had been disappointingly unsuccessful for antibiotic research. Understanding of this lack of success has increased substantially and the lessons learned refer to characteristics of targets, screening libraries and screening strategies. The 'genomics' approach was replaced by a diverse array of discovery strategies, for example, searching for new natural product leads among previously abandoned compounds or new microbial sources, screening for synthetic inhibitors by targeted approaches including structure-based design and analyses of focused libraries and designing resistance-breaking properties into antibiotics of established classes. Furthermore, alternative treatment options are being pursued including anti-virulence strategies and immunotherapeutic approaches. This article summarizes the lessons learned from the genomics era and describes discovery strategies resulting from that knowledge.
Tidjarat, Siripran; Winotapun, Weerapath; Opanasopit, Praneet; Ngawhirunpat, Tanasait; Rojanarata, Theerasak
2014-11-07
Uniaxially aligned cellulose acetate (CA) nanofibers were successfully fabricated by electrospinning and applied to use as stationary phase for thin layer chromatography. The control of alignment was achieved by using a drum collector rotating at a high speed of 6000 rpm. Spin time of 6h was used to produce the fiber thickness of about 10 μm which was adequate for good separation. Without any chemical modification after the electrospinning process, CA nanofibers could be readily devised for screening hydroquinone (HQ) and retinoic acid (RA) adulterated in cosmetics using the mobile phase consisting of 65:35:2.5 methanol/water/acetic acid. It was found that the separation run on the aligned nanofibers over a distance of 5 cm took less than 15 min which was two to three times faster than that on the non-aligned ones. On the aligned nanofibers, the masses of HQ and RA which could be visualized were 10 and 25 ng, respectively, which were two times lower than those on the non-aligned CA fibers and five times lower than those on conventional silica plates due to the appearance of darker and sharper of spots on the aligned nanofibers. Furthermore, the proposed method efficiently resolved HQ from RA and ingredients commonly found in cosmetic creams. Due to the satisfactory analytical performance, facile and inexpensive production process, uniaxially aligned electrospun CA nanofibers are promising alternative media for planar chromatography. Copyright © 2014 Elsevier B.V. All rights reserved.
Lyin’ Eyes: Ocular-motor Measures of Reading Reveal Deception
Cook, Anne E.; Hacker, Douglas J.; Webb, Andrea K.; Osher, Dahvyn; Kristjansson, Sean; Woltz, Dan J.; Kircher, John C.
2013-01-01
Our goal was to evaluate an alternative to current methods for detecting deception in security screening contexts. We evaluated a new cognitive-based test of deception that measured participants’ ocular-motor responses (pupil responses and reading behaviors) while they read and responded to statements on a computerized questionnaire. In Experiment 1, participants from a university community were randomly assigned to either a “guilty” group that committed one of two mock crimes or an “innocent” group that only learned about the crime. Participants then reported for testing, where they completed the computer-administered questionnaire that addressed their possible involvement in the crimes. Experiment 2 also manipulated participants’ incentive to pass the test and difficulty of statements on the test. In both experiments, guilty participants had increased pupil responses to statements answered deceptively; however, they spent less time fixating on, reading, and re-reading those statements than statements answered truthfully. These ocular-motor measures were optimally weighted in a discrimination function that correctly classified 85% of participants as either guilty or innocent. Findings from Experiment 2 indicated that group discrimination was improved with greater incentives to pass the test and the use of statements with simple syntax. The present findings suggest that two cognitive processes are involved in deception -- vigilance and strategy -- and that these processes are reflected in different ocular-motor measures. The ocular-motor test reported here represents a new approach to detecting deception that may fill an important need in security screening contexts. PMID:22545928
Van de Wouwer, Dorien; Decou, Raphaël; Audenaert, Dominique; Nguyen, Long
2016-01-01
Plant secondary-thickened cell walls are characterized by the presence of lignin, a recalcitrant and hydrophobic polymer that provides mechanical strength and ensures long-distance water transport. Exactly the recalcitrance and hydrophobicity of lignin put a burden on the industrial processing efficiency of lignocellulosic biomass. Both forward and reverse genetic strategies have been used intensively to unravel the molecular mechanism of lignin deposition. As an alternative strategy, we introduce here a forward chemical genetic approach to find candidate inhibitors of lignification. A high-throughput assay to assess lignification in Arabidopsis (Arabidopsis thaliana) seedlings was developed and used to screen a 10-k library of structurally diverse, synthetic molecules. Of the 73 compounds that reduced lignin deposition, 39 that had a major impact were retained and classified into five clusters based on the shift they induced in the phenolic profile of Arabidopsis seedlings. One representative compound of each cluster was selected for further lignin-specific assays, leading to the identification of an aromatic compound that is processed in the plant into two fragments, both having inhibitory activity against lignification. One fragment, p-iodobenzoic acid, was further characterized as a new inhibitor of CINNAMATE 4-HYDROXYLASE, a key enzyme of the phenylpropanoid pathway synthesizing the building blocks of the lignin polymer. As such, we provide proof of concept of this chemical biology approach to screen for inhibitors of lignification and present a broad array of putative inhibitors of lignin deposition for further characterization. PMID:27485881
Cost-effectiveness of cervical cancer screening with primary human papillomavirus testing in Norway.
Burger, E A; Ortendahl, J D; Sy, S; Kristiansen, I S; Kim, J J
2012-04-24
New screening technologies and vaccination against human papillomavirus (HPV), the necessary cause of cervical cancer, may impact optimal approaches to prevent cervical cancer. We evaluated the cost-effectiveness of alternative screening strategies to inform cervical cancer prevention guidelines in Norway. We leveraged the primary epidemiologic and economic data from Norway to contextualise a simulation model of HPV-induced cervical cancer. The current cytology-only screening was compared with strategies involving cytology at younger ages and primary HPV-based screening at older ages (31/34+ years), an option being actively deliberated by the Norwegian government. We varied the switch-age, screening interval, and triage strategies for women with HPV-positive results. Uncertainty was evaluated in sensitivity analysis. Current cytology-only screening was less effective and more costly than strategies that involve switching to primary HPV testing in older ages. For unvaccinated women, switching at age 34 years to primary HPV testing every 4 years was optimal given the Norwegian cost-effectiveness threshold ($83,000 per year of life saved). For vaccinated women, a 6-year screening interval was cost-effective. When we considered a wider range of strategies, we found that an earlier switch to HPV testing (at age 31 years) may be preferred. Strategies involving a switch to HPV testing for primary screening in older women is expected to be cost-effective compared with current recommendations in Norway.
Enhancement of the cervical cancer screening program in Malaysia: a qualitative study.
Abdullah, Fauziah; Su, Tin Tin
2010-01-01
Cervical cancer has long been known as a preventable disease. Yet it still is a prime women's health issue globally. In Malaysia, the current cervical cancer screening program, introduced in the 1960s, has been found to be unsuccessful in terms of Pap smear coverage. The aim of this study is to determine providers perceptives on the program and the feasibility of practicing an organized cervical screening program in Malaysia. 11 key informant interviews were conducted with policy makers and health care providers from the Ministry of Health in Malaysia from October 2009 to May 2010. Interviewees' perceptions were explored on current and organized cervical screening program based on their expertise and experience. The results highlighted that the existing cervical screening program in Malaysia faced flaws at all levels that failed to reduce cervical cancer morbidity and mortality. The identified weaknesses were poor acceptance by women, lack of commitment by health care providers, nature of the program, an improper follow-up system, limited resources and other competing needs. Complementarily, all interviewees perceived an organized cervical screening program as an alternative approach both feasible and acceptable by women and government to practice in Malaysia. Better screening coverage depends on an effective screening program that incorporates a behaviour-based strategy. A new program should be focused in the policy-making context to improve screening coverage and to effectively combat cervical cancer.
Health, safety, and ecological implications of using biobased floor-stripping products.
Massawe, Ephraim; Geiser, Kenneth; Ellenbecker, Michael; Marshall, Jason
2007-05-01
The main objective of the study reported here was to investigate the ecological, health, and safety (EHS) implications of using biobased floor strippers as alternatives to solvent-based products such as Johnson Wax Professional (Pro Strip). The authors applied a quick EHS-scoring technique developed by the Surface Solution Laboratory (SSL) of the Toxics Use Reduction Institute (TURI) to some alternative, biobased products that had previously performed as well as or close to as well as the currently used product. The quick technique is considered an important step in EHS assessment, particularly for toxics use reduction planners and advocates who may not have the resources to subject many alternative products or processes at once to detailed EHS analysis. Taking this step narrows available options to a manageable number. (Technical-performance experiments were also conducted, but the results are not discussed or reported in this paper). The cost of switching to biobased floor strippers was assessed and compared with the cost of using the traditional product, both at full strength and at the dilution ratios recommended by the respective manufacturers. The EHS analysis was based on a framework consisting of five parameters: volatile organic compounds (VOCs); pH; global-warming potential (GWP); ozone depletion potential (ODP); and safety scores in areas such as flammability, stability, and special hazards, based on ratings from the Hazardous Material Classification System (HMIS) and the National Fire Protection Association (NFPA). Total EHS scores were calculated with data derived from the material safety data sheets. For most cleaning products previously investigated by the TURI SSL, the investigators have demonstrated that the five key parameters used in the study reported here can successfully be used for quick screening of the EHS impacts of cleaning alternatives. All eight biobased, or green, products evaluated in the study had better EHS-screening scores than did Pro Strip. One product, Botanic Gold, had a screening score of 49 out of a possible 50. This score was much higher than the score of 26 achieved by Pro Strip. The other biobased floor strippers had EHS-screening scores of > or =37, which is the average value of solvent-based cleaning solutions. These results indicate that biobased cleaning products capable of floor stripping are potentially better than traditional products with respect to the five EHS parameters used. The cost of switching to biobased floor strippers at their full strength ranged from a minimum of U.S. $15.50 per gallon ($4.10 per liter) for Eco Natural Floor Stripper (WPR) to about $59.00 per gallon ($15.61 per liter) for Botanic Gold. At 25 percent volume by volume (v/v), the recommended dilution ratio for the traditional product, the cost of the Botanic Gold was $14.75 per gallon ($3.90 per liter), or about five times more than that of Pro Strip, which was $2.48 per gallon ($0.65 per liter). Since these figures do not reflect all of the EHS costs, such as disposal and recycling fees, it is likely that use of Botanic Gold could be cost-effective in the long run. The authors therefore recommend that detailed EHS analysis be conducted on this alternative biobased floor stripper. It is also recommended that large field trials be conducted and that janitors' or consumers' perceptions be determined. For detailed assessment of eco-toxicological properties of the biobased floor strippers, investigations of the common additives in the Botanic Gold formulation should be conducted through use of databases on the World Wide Web such as Toxnet. Finally, the current policies, regulations, and standards that promote biobased products should be investigated to determine their strengths and weaknesses. This would encourage a broader public debate about the future of the biobased industry in the context of sustainability.
Targeting the Synthetic Essential Kinases of Breast Cancers
2016-05-01
comments regarding the problems associated with siRNA screening and that CRISPR ‐Cas is a better alternative. I am a bit confused by this argument since the...SOW called for siRNA screening first followed by CRISPR ‐Cas validation. It is also not clear why genome wide CRISPR knock‐out is necessary since the...validated the phenotypes and made great progress on the mechanisms. As for the CRISPR -screens, we wish to accomplish several purposes. We plan to first
Majewski, Stanislaw; Weisenberger, Andrew G.; Wojcik, Randolph F.; Steinbach, Daniela
1999-01-01
A high resolution gamma ray imaging device includes an aluminum housing, a lead screen collimator at an opened end of the housing, a crystal scintillator array mounted behind the lead screen collimator, a foam layer between the lead screen collimator and the crystal scintillator array, a photomultiplier window coupled to the crystal with optical coupling grease, a photomultiplier having a dynode chain body and a base voltage divider with anodes, anode wire amplifiers each connected to four anodes and a multi pin connector having pin connections to each anode wire amplifier. In one embodiment the crystal scintillator array includes a yttrium aluminum perovskite (YAP) crystal array. In an alternate embodiment, the crystal scintillator array includes a gadolinium oxyorthosilicate (GSO) crystal array.
ERIC Educational Resources Information Center
Sidi, Yael; Ophir, Yael; Ackerman, Rakefet
2016-01-01
Screen inferiority in performance and metacognitive processes has been repeatedly found with text learning. Common explanations for screen inferiority relate to technological and physiological disadvantages associated with extensive reading on screen. However, recent studies point to lesser recruitment of mental effort on screen than on paper.…
Berrue, Fabrice; Withers, Sydnor T; Haltli, Brad; Withers, Jo; Kerr, Russell G
2011-03-21
Marine invertebrates have proven to be a rich source of secondary metabolites. The growing recognition that marine microorganisms associated with invertebrate hosts are involved in the biosynthesis of secondary metabolites offers new alternatives for the discovery and development of marine natural products. However, the discovery of microorganisms producing secondary metabolites previously attributed to an invertebrate host poses a significant challenge. This study describes an efficient chemical screening method utilizing a 96-well plate-based bacterial cultivation strategy to identify and isolate microbial producers of marine invertebrate-associated metabolites.
The Trojan Horse Method in nuclear astrophysics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spitaleri, C., E-mail: spitaleri@lns.infn.it; Mukhamedzhanov, A. M.; Blokhintsev, L. D.
2011-12-15
The study of energy production and nucleosynthesis in stars requires an increasingly precise knowledge of the nuclear reaction rates at the energies of interest. To overcome the experimental difficulties arising from the small cross sections at those energies and from the presence of the electron screening, the Trojan Horse Method has been introduced. The method provides a valid alternative path to measure unscreened low-energy cross sections of reactions between charged particles, and to retrieve information on the electron screening potential when ultra-low energy direct measurements are available.
CRISPR-STOP: gene silencing through base-editing-induced nonsense mutations.
Kuscu, Cem; Parlak, Mahmut; Tufan, Turan; Yang, Jiekun; Szlachta, Karol; Wei, Xiaolong; Mammadov, Rashad; Adli, Mazhar
2017-07-01
CRISPR-Cas9-induced DNA damage may have deleterious effects at high-copy-number genomic regions. Here, we use CRISPR base editors to knock out genes by changing single nucleotides to create stop codons. We show that the CRISPR-STOP method is an efficient and less deleterious alternative to wild-type Cas9 for gene-knockout studies. Early stop codons can be introduced in ∼17,000 human genes. CRISPR-STOP-mediated targeted screening demonstrates comparable efficiency to WT Cas9, which indicates the suitability of our approach for genome-wide functional screenings.
Pfeil, Johannes; Listl, Stefan; Hoffmann, Georg F; Kölker, Stefan; Lindner, Martin; Burgard, Peter
2013-10-17
Glutaric aciduria type I (GA-I) is a rare metabolic disorder caused by inherited deficiency of glutaryl-CoA dehydrogenase. Despite high prognostic relevance of early diagnosis and start of metabolic treatment as well as an additional cost saving potential later in life, only a limited number of countries recommend newborn screening for GA-I. So far only limited data is available enabling health care decision makers to evaluate whether investing into GA-I screening represents value for money. The aim of our study was therefore to assess the cost-effectiveness of newborn screening for GA-I by tandem mass spectrometry (MS/MS) compared to a scenario where GA-I is not included in the MS/MS screening panel. We assessed the cost-effectiveness of newborn screening for GA-I against the alternative of not including GA-I in MS/MS screening. A Markov model was developed simulating the clinical course of screened and unscreened newborns within different time horizons of 20 and 70 years. Monte Carlo simulation based probabilistic sensitivity analysis was used to determine the probability of GA-I screening representing a cost-effective therapeutic strategy. Within a 20 year time horizon, GA-I screening averts approximately 3.7 DALYs (95% CI 2.9 - 4.5) and about one life year is gained (95% CI 0.7 - 1.4) per 100,000 neonates screened initially . Moreover, the screening programme saves a total of around 30,682 Euro (95% CI 14,343 to 49,176 Euro) per 100,000 screened neonates over a 20 year time horizon. Within the limitations of the present study, extending pre-existing MS/MS newborn screening programmes by GA-I represents a highly cost-effective diagnostic strategy when assessed under conditions comparable to the German health care system.
At what costs will screening with CT colonography be competitive? A cost-effectiveness approach.
Lansdorp-Vogelaar, Iris; van Ballegooijen, Marjolein; Zauber, Ann G; Boer, Rob; Wilschut, Janneke; Habbema, J Dik F
2009-03-01
The costs of computed tomographic colonography (CTC) are not yet established for screening use. In our study, we estimated the threshold costs for which CTC screening would be a cost-effective alternative to colonoscopy for colorectal cancer (CRC) screening in the general population. We used the MISCAN-colon microsimulation model to estimate the costs and life-years gained of screening persons aged 50-80 years for 4 screening strategies: (i) optical colonoscopy; and CTC with referral to optical colonoscopy of (ii) any suspected polyp; (iii) a suspected polyp >or=6 mm and (iv) a suspected polyp >or=10 mm. For each of the 4 strategies, screen intervals of 5, 10, 15 and 20 years were considered. Subsequently, for each CTC strategy and interval, the threshold costs of CTC were calculated. We performed a sensitivity analysis to assess the effect of uncertain model parameters on the threshold costs. With equal costs ($662), optical colonoscopy dominated CTC screening. For CTC to gain similar life-years as colonoscopy screening every 10 years, it should be offered every 5 years with referral of polyps >or=6 mm. For this strategy to be as cost-effective as colonoscopy screening, the costs must not exceed $285 or 43% of colonoscopy costs (range in sensitivity analysis: 39-47%). With 25% higher adherence than colonoscopy, CTC threshold costs could be 71% of colonoscopy costs. Our estimate of 43% is considerably lower than previous estimates in literature, because previous studies only compared CTC screening to 10-yearly colonoscopy, where we compared to different intervals of colonoscopy screening.
Bias in ground-water data caused by well-bore flow in long-screen wells
Church, P.E.; Granato, G.E.
1996-01-01
The results of a field experiment comparing water-quality constituents, specific conductance, geophysical measurements, and well-bore hydraulics in two long-screen wells and adjacent vertical clusters of short-screen wells show bias in ground-water data caused by well-bore flow in long-screen wells. The well screen acts as a conduit for vertical flow because it connects zones of different head and transmissivity, even in a relatively homogeneous, unconfined, sand and gravel aquifer where such zones are almost indistinguishable. Flow in the well bore redistributes water and solutes in the aquifer adjacent to the well, increasing the risk of bias in water-quality samples, failure of plume detection, and cross-contamination of the aquifer. At one site, downward flow from a contaminated zone redistributes solutes over the entire length of the long-screen well. At another site, upward flow from an uncontaminated zone masks the presence of road salt plume. Borehole induction logs, conducted in a fully penetrating short-screen well, can provide a profile of solutes in the aquifer that is not attainable in long-screen wells. In this study, the induction-log profiles show close correlation with data from analyses of water-quality samples from the short-screen wells; however, both of these data sets differ markedly from the biased water-quality samples from the long-screen wells. Therefore, use of induction logs in fully cased wells for plume detection and accurate placement of short-screen wells is a viable alternative to use of long screen wells for water-quality sampling.
A closer look: Alternative pain management practices by heart failure patients with chronic pain.
McDonald, Deborah Dillon; Soutar, Christina; Chan, Maria Agudelo; Afriyie, Angela
2015-01-01
To describe alternative non-pharmaceutical non-nutraceutical pain self-management strategies used by people with heart failure (HF) in order to reduce chronic non-cardiac pain. Little is known about alternative pain self-treatments used by HF patients with chronic pain. A cross-sectional descriptive design was used with 25 hospitalized HF patients who had chronic pain and used at least one alternative pain treatment. Pain intensity, pain interference with function, and current pain treatments were measured with the Brief Pain Inventory. Alternative treatments included walking, stretching, use of heat and cold. Five patients used evidence-based pain treatments for their chronic pain conditions. Patients reported moderate pain intensity and pain interference with activity. Patients with HF and chronic pain use few alternative pain treatments. Screening for chronic pain and referral to Integrative Medicine and/or Palliative care for a pain management consult might reduce the added burden of pain in people with HF. Copyright © 2015 Elsevier Inc. All rights reserved.
Alternative Host Models for Testing Anti-Protozoal or Antifungal Compounds and Fungal Infection.
Torrecilhas, Ana Claudia; Xander, Patricia; Ferreira, Karen Spadari; Batista, Wagner Luiz
2018-01-01
The neglected tropical diseases (NTDs) are caused by several parasites, fungi, bacteria and viruses and affect more than one billion people in the world. The control and prevention against NTDs need implementation of alternative methods for testing new compounds against these diseases. For the implementation of alternative methods, it is necessary to apply the principles of replacement, reduction and refinement (the 3Rs) for the use of laboratory animals. Accordingly, the present review addressed a variety of alternative models to study the infections caused by protozoa and fungi. Overall, vertebrate and invertebrate models of fungal infection have been used to elucidate host-pathogen interactions. However, until now the insect model has not been used in protozoal studies as an alternative method, but there is interest in the scientific community to try new tools to screen alternative drugs to control and prevent protozoal infections. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
The cost-effectiveness of screening for oral cancer in primary care.
Speight, P M; Palmer, S; Moles, D R; Downer, M C; Smith, D H; Henriksson, M; Augustovski, F
2006-04-01
To use a decision-analytic model to determine the incremental costs and outcomes of alternative oral cancer screening programmes conducted in a primary care environment. The cost-effectiveness of oral cancer screening programmes in a number of primary care environments was simulated using a decision analysis model. Primary data on actual resource use and costs were collected by case note review in two hospitals. Additional data needed to inform the model were obtained from published costs, from systematic reviews and by expert opinion using the Trial Roulette approach. The value of future research was determined using expected value of perfect information (EVPI) for the decision to screen and for each of the model inputs. Hypothetical screening programmes conducted in a number of primary care settings. Eight strategies were compared: (A) no screen; (B) invitational screen--general medical practice; (C) invitational screen--general dental practice; (D) opportunistic screen--general medical practice; (E) opportunistic screen--general dental practice; (F) opportunistic high-risk screen--general medical practice; (G) opportunistic high-risk screen--general dental practice; and (H) invitational screen--specialist. A hypothetical population over the age of 40 years was studied. The main measures were mean lifetime costs and quality-adjusted life-years (QALYs) of each alternative screening scenario and incremental cost-effectiveness ratios (ICERs) to determine the additional costs and benefits of each strategy over another. No screening (strategy A) was always the cheapest option. Strategies B, C, E and H were never cost-effective and were ruled out by dominance or extended dominance. Of the remaining strategies, the ICER for the whole population (age 49-79 years) ranged from pound 15,790 to pound 25,961 per QALY. Modelling a 20% reduction in disease progression always gave the lowest ICERs. Cost-effectiveness acceptability curves showed that there is considerable uncertainty in the optimal decision identified by the ICER, depending on both the maximum amount that the NHS may be prepared to pay and the impact that treatment has on the annual malignancy transformation rate. Overall, however, high-risk opportunistic screening by a general dental or medical practitioner (strategies F and G) may be cost-effective. EVPIs were high for all parameters with population values ranging from pound 8 million to pound 462 million. However, the values were significantly higher in males than females but also varied depending on malignant transformation rate, effects of treatment and willingness to pay. Partial EVPIs showed the highest values for malignant transformation rate, disease progression, self-referral and costs of cancer treatment. Opportunistic high-risk screening, particularly in general dental practice, may be cost-effective. This screening may more effectively be targeted to younger age groups, particularly 40-60 year olds. However, there is considerable uncertainty in the parameters used in the model, particularly malignant transformation rate, disease progression, patterns of self-referral and costs. Further study is needed on malignant transformation rates of oral potentially malignant lesions and to determine the outcome of treatment of oral potentially malignant lesions. Evidence has been published to suggest that intervention has no greater benefit than 'watch and wait'. Hence a properly planned randomised controlled trial may be justified. Research is also needed into the rates of progression of oral cancer and on referral pathways from primary to secondary care and their effects on delay and stage of presentation.
Fluorescent screens and image processing for the APS linac test stand
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berg, W.; Ko, K.
A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image processing will also be discussed.
Blacket, Mark J; Malipatil, Mali B; Semeraro, Linda; Gillespie, Peter S; Dominiak, Bernie C
2017-04-01
Understanding the relationship between incursions of insect pests and established populations is critical to implementing effective control. Studies of genetic variation can provide powerful tools to examine potential invasion pathways and longevity of individual pest outbreaks. The major fruit fly pest in eastern Australia, Queensland fruit fly Bactrocera tryoni (Froggatt), has been subject to significant long-term quarantine and population reduction control measures in the major horticulture production areas of southeastern Australia, at the species southern range limit. Previous studies have employed microsatellite markers to estimate gene flow between populations across this region. In this study, we used an independent genetic marker, mitochondrial DNA (mtDNA) sequences, to screen genetic variation in established and adjacent outbreak populations in southeastern Australia. During the study period, favorable environmental conditions resulted in multiple outbreaks, which appeared genetically distinctive and relatively geographically localized, implying minimal dispersal between simultaneous outbreaks. Populations in established regions were found to occur over much larger areas. Screening mtDNA (female) lineages proved to be an effective alternative genetic tool to assist in understanding fruit fly population dynamics and provide another possible molecular method that could now be employed for better understanding of the ecology and evolution of this and other pest species.
Metushi, Imir G; Fitzgerald, Robert L; McIntyre, Iain M
2016-05-01
Alternative specimens have been occasionally considered as substitutes for whole blood for postmortem toxicology testing. We studied the applicability of vitreous humor, and evaluated whether it would be suitable to replace (or augment) whole blood for routine drug screening. Results showed that from 51 autopsy cases, we were able to identify an aggregate of 209 findings in whole blood compared with 169 in vitreous. The total number of compounds identified was 71 for whole blood and 60 for vitreous humor. Quantitative analysis showed that whole-blood concentrations of trazodone were several fold higher than vitreous humor concentrations (1.42 ± 0.57 vs. 0.15 ± 0.05 mg/L, respectively) and similar results were also obtained for diazepam (0.37 ± 0.06 vs. 0.13 ± 0.01, respectively). For other drugs such as oxycodone, hydrocodone and doxylamine, a trend suggesting higher concentrations in vitreous humor vs. whole blood was observed; however, this was not significant. Our results are consistent with the limited work of other investigators, and suggest that vitreous humor could be an appropriate matrix for drug screening in postmortem toxicology. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
10 CFR 960.3-2 - Siting process.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Siting process. 960.3-2 Section 960.3-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3-2 Siting process. The siting process begins with site screening...
10 CFR 960.3-2 - Siting process.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Siting process. 960.3-2 Section 960.3-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3-2 Siting process. The siting process begins with site screening...
10 CFR 960.3-2 - Siting process.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Siting process. 960.3-2 Section 960.3-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3-2 Siting process. The siting process begins with site screening...
10 CFR 960.3-2 - Siting process.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Siting process. 960.3-2 Section 960.3-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3-2 Siting process. The siting process begins with site screening...
NASA Technical Reports Server (NTRS)
Bair, E. K.
1986-01-01
The unbiased selection of the Space Transportation Main Engine (STME) configuration requires that the candidate engines be evaluated against a predetermined set of criteria which must be properly weighted to emphasize critical requirements defined prior to the actual evaluation. The evaluation and selection process involves the following functions: (1) determining if a configuration can satisfy basic STME requirements (yes/no); (2) defining the evaluation criteria; (3) selecting the criteria relative importance or weighting; (4) determining the weighting sensitivities; and (5) establishing a baseline for engine evaluation. The criteria weighting and sensitivities are cost related and are based on mission models and vehicle requirements. The evaluation process is used as a coarse screen to determine the candidate engines for the parametric studies and as a fine screen to determine concept(s) for conceptual design. The criteria used for the coarse and fine screen evaluation process is shown. The coarse screen process involves verifying that the candidate engines can meet the yes/no screening requirements and a semi-subjective quantitative evaluation. The fine screen engines have to meet all of the yes/no screening gates and are then subjected to a detailed evaluation or assessment using the quantitative cost evaluation processes. The option exists for re-cycling a concept through the quantitative portion of the screening and allows for some degree of optimization. The basic vehicle is a two stage LOX/HC, LOX/LH2 parallel burn vehicle capable of placing 150,000 lbs in low Earth orbit (LEO).
The U.S. EPA is developing alternative screening methods to identify putative developmental neurotoxicants and prioritize chemicals for additional testing. One method developmentally exposes zebrafish embryos and assesses nervous system structure at 2 days post-fertilization (dpf...
An Evaluation of Alternative Screening Procedures.
ERIC Educational Resources Information Center
Reid, Carol; Romanoff, Brenda; Algozzine, Bob; Udall, Ann
2000-01-01
This study compared the Problem Solving Assessment (PSA) procedure, an application based on Gardner's theory of multiple intelligences, with more traditional criteria for the identification of minority students for gifted education programs. Although positive correlations among approaches and intelligences were observed, different groups of…
20180312 - Mechanistic Modeling of Developmental Defects through Computational Embryology (SOT)
Significant advances in the genome sciences, in automated high-throughput screening (HTS), and in alternative methods for testing enable rapid profiling of chemical libraries for quantitative effects on diverse cellular activities. While a surfeit of HTS data and information is n...
Improving colon cancer screening in community clinics.
Davis, Terry; Arnold, Connie; Rademaker, Alfred; Bennett, Charles; Bailey, Stacy; Platt, Daci; Reynolds, Cristalyn; Liu, Dachao; Carias, Edson; Bass, Pat; Wolf, Michael
2013-11-01
The authors evaluated the effectiveness and cost effectiveness of 2 interventions designed to promote colorectal cancer (CRC) screening in safety-net settings. A 3-arm, quasi-experimental evaluation was conducted among 8 clinics in Louisiana. Screening efforts included: 1) enhanced usual care, 2) literacy-informed education of patients, and 3) education plus nurse support. Overall, 961 average-risk patients ages 50 to 85 years were eligible for routine CRC screening and were recruited. Outcomes included CRC screening completion and incremental cost effectiveness using literacy-informed education of patients and education plus nurse support versus enhanced usual care. The baseline screening rate was <3%. After the interventions, the screening rate was 38.6% with enhanced usual care, 57.1% with education, and 60.6% with education that included additional nurse support. After adjusting for age, race, sex, and literacy, patients who received education alone were not more likely to complete screening than those who received enhanced usual care; and those who received additional nurse support were 1.60-fold more likely to complete screening than those who received enhanced usual care (95% confidence interval, 1.06-2.42; P = .024). The incremental cost per additional individual screened was $1337 for education plus nurse support over enhanced usual care. Fecal occult blood test rates were increased beyond enhanced usual care by providing brief education and nurse support but not by providing education alone. More cost-effective alternatives to nurse support need to be investigated. © 2013 American Cancer Society.
Veronesi, Giulia; Colombo, Paolo; Novellis, Pierluigi; Crepaldi, Alessandro; Lutman, Romano Fabio; Dieci, Elisa; Profili, Manuel; Siracusano, Licia; Alloisio, Marco
2017-03-01
Widespread lung cancer screening with low-dose computed tomography is urgently needed in Europe to identify lung cancers early and reduce lung cancer deaths. The most effective method of identifying high-risk individuals and recruiting them for screening has not been determined. In the present pilot study we investigated direct telephoning to families as a way of identifying high risk individuals and recruiting them to a screening/smoking cessation program, that avoided the selection bias of voluntary screening. Families in the province of Milan, Italy, were contacted by telephone at their homes and asked about family members over 50 years who were heavy smokers (30 or more pack-years). Persons meeting these criteria were contacted and asked to participate in the program. Those who agreed were given an appointment to undergo screening and receive smoking cessation counseling. Among the 1000 contacted families, involving 2300 persons, 44 (1.9%) were eligible for LDCT screening, and 12 (27%) of these participated in the program. The cost of this recruitment strategy pilot study was around 150 euro per screened subject. We obtained useful information on the proportion of the general population eligible for lung cancer screening and the proportion of those who responded. However the cost of home telephone calling is probably too high to be practicable as a method of recruiting high risk persons for screening. Alternative recruitment methods, possibly involving family physicians practitioners, need to be investigated. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Zhang, Litao; Cvijic, Mary Ellen; Lippy, Jonathan; Myslik, James; Brenner, Stephen L; Binnie, Alastair; Houston, John G
2012-07-01
In this paper, we review the key solutions that enabled evolution of the lead optimization screening support process at Bristol-Myers Squibb (BMS) between 2004 and 2009. During this time, technology infrastructure investment and scientific expertise integration laid the foundations to build and tailor lead optimization screening support models across all therapeutic groups at BMS. Together, harnessing advanced screening technology platforms and expanding panel screening strategy led to a paradigm shift at BMS in supporting lead optimization screening capability. Parallel SAR and structure liability relationship (SLR) screening approaches were first and broadly introduced to empower more-rapid and -informed decisions about chemical synthesis strategy and to broaden options for identifying high-quality drug candidates during lead optimization. Copyright © 2012 Elsevier Ltd. All rights reserved.
Identification of small molecule inhibitors of cytokinesis and single cell wound repair
Clark, Andrew G.; Sider, Jenny R.; Verbrugghe, Koen; Fenteany, Gabriel; von Dassow, George; Bement, William M.
2013-01-01
Screening of small molecule libraries offers the potential to identify compounds that inhibit specific biological processes and, ultimately, to identify macromolecules that are important players in such processes. To date, however, most screens of small molecule libraries have focused on identification of compounds that inhibit known proteins or particular steps in a given process, and have emphasized automated primary screens. Here we have used “low tech” in vivo primary screens to identify small molecules that inhibit both cytokinesis and single cell wound repair, two complex cellular processes that possess many common features. The “diversity set”, an ordered array of 1990 compounds available from the National Cancer Institute, was screened in parallel to identify compounds that inhibit cytokinesis in D. excentricus (sand dollar) embryos and single cell wound repair in X. laevis (frog) oocytes. Two small molecules were thus identified: Sph1 and Sph2. Sph1 reduces Rho activation in wound repair and suppresses formation of the spindle midzone during cytokinesis. Sph2 also reduces Rho activation in wound repair and may inhibit cytokinesis by blocking membrane fusion. The results identify two small molecules of interest for analysis of wound repair and cytokinesis, reveal that these processes are more similar than often realized and reveal the potential power of low tech screens of small molecule libraries for analysis of complex cellular processes. PMID:23125193
Fatigue failure of regenerator screens in a high frequency Stirling engine
NASA Technical Reports Server (NTRS)
Hull, David R.; Alger, Donald L.; Moore, Thomas J.; Scheuermann, Coulson M.
1988-01-01
Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.
Inclusive intake screening: shaping medical problems into specialist-appropriate cases.
Jean, Yvette A
2004-05-01
This paper examines medical intake screening through the process of making appointments with medical specialists. By employing a multi-method, qualitative approach, it shows how decisions to schedule doctors' appointments are based on medical knowledge about physicians' specialties and specific organisational practices. It draws on insights from first-contact interactions between clients and institutional gatekeepers to enrich our understanding of intake screening. In relation to gatekeeping, rationing commonly gets framed as restrictive screening practices, with a preference for denying or limiting access to treatment. Restrictive screening practices are typically organised to elicit a narrow range of information ('facts') relevant to specific eligibility criteria; whereas inclusive intake screening tends to involve less scripted, more complex and open-ended interactional exchanges between workers and clients, wherein workers help clients frame their claims in ways that will increase their chances of getting accepted. Front-office workers hold a preference for inclusive intake screening, a preference that is undergirded by the referral-driven nature of this stage of patient processing, and by a work environment that favours inclusive screening. This finding builds on the literature within medical sociology, but also extends our understanding of frontline decision-making and the distribution of resources within a variety of people-processing institutions.
ERIC Educational Resources Information Center
Peace Corps, Washington, DC. Information Collection and Exchange Div.
Focusing on the production and utilization of printing processes in constructing effective visuals for teaching, this bulletin contains articles on the silk screening stencil process, use of a similar process with a portable mimeograph, and the hectograph process. The first article lists equipment needed to make a silk screen, steps in building…
Hasker, Epco; Lutumba, Pascal; Mumba, Dieudonné; Lejon, Veerle; Büscher, Phillipe; Kande, Victor; Muyembe, Jean Jacques; Menten, Joris; Robays, Jo; Boelaert, Marleen
2010-01-01
Control of human African trypanosomiasis (HAT) in the Democratic Republic of Congo is based on mass population screening by mobile teams; a costly and labor-intensive approach. We hypothesized that blood samples collected on filter paper by village health workers and processed in a central laboratory might be a cost-effective alternative. We estimated sensitivity and specificity of micro-card agglutination test for trypanosomiasis (micro-CATT) and enzyme-linked immunosorbent assay (ELISA)/T.b. gambiense on filter paper samples compared with parasitology-based case classification and used the results in a Monte Carlo simulation of a lot quality assurance sampling (LQAS) approach. Micro-CATT and ELISA/T.b. gambiense showed acceptable sensitivity (92.7% [95% CI 87.4–98.0%] and 82.2% [95% CI 75.3–90.4%]) and very high specificity (99.4% [95% CI 99.0–99.9%] and 99.8% [95% CI 99.5–100%]), respectively. Conditional on high sample size per lot (≥ 60%), both tests could reliably distinguish a 2% from a zero prevalence at village level. Alternatively, these tests could be used to identify individual HAT suspects for subsequent confirmation. PMID:20682885
Lei, Beilei; Liu, Jiyuan; Yao, Xiaojun
2015-12-01
Brassinosteroid (BR) phytohormones play indispensable roles in plant growth and development. Brassinolide (BL) and 24-epibrassinolide (24-epiBL) are the most active ones among the BRs reported thus far. Unfortunately, the extremely low natural content and intricate synthesis process limit their popularization in agricultural production. Earlier reports to discover alternative compounds have resulted in molecules with nearly same scaffold structure and without diversity in chemical space. In the present study, receptors structure based BRs regulation mechanism was analyzed. First, we examined the detailed binding interactions and their dynamic stability between BL and its receptor BRI1 and co-receptor BAK1. Then, the binding modes and binding free energies for 24-epiBL and a series of representative BRs binding with BRI1 and BRI1-BAK1 were carried out by molecular docking, energy minimization and MM-PBSA free energy calculation. The obtained binding structures and energetic results provided vital insights into the structural factors affecting the activity from both receptors and BRs aspects. Subsequently, the obtained knowledge will serve as valuable guidance to build pharmacophore models for rational screening of new scaffold alternative BRs. Copyright © 2015 Elsevier Inc. All rights reserved.
Ying, William; Levons, Jaquan K; Carney, Andrea; Gandhi, Rajesh; Vydra, Vicky; Rubin, A Erik
2016-06-01
A novel semiautomated buffer exchange process workflow was developed to enable efficient early protein formulation screening. An antibody fragment protein, BMSdab, was used to demonstrate the workflow. The process afforded 60% to 80% cycle time and scientist time savings and significant material efficiencies. These efficiencies ultimately facilitated execution of this stability work earlier in the drug development process, allowing this tool to inform the developability of potential candidates for development from a formulation perspective. To overcome the key technical challenges, the protein solution was buffer-exchanged by centrifuge filtration into formulations for stability screening in a 96-well plate with an ultrafiltration membrane, leveraging automated liquid handling and acoustic volume measurements to allow several cycles of exchanges. The formulations were transferred into a vacuum manifold and sterile filtered into a rack holding 96 glass vials. The vials were sealed with a capmat of individual caps and placed in stability stations. Stability of the samples prepared by this process and by the standard process was demonstrated to be comparable. This process enabled screening a number of formulations of a protein at an early pharmaceutical development stage with a short sample preparation time. © 2015 Society for Laboratory Automation and Screening.
Soh, Josephine Lay Peng; Grachet, Maud; Whitlock, Mark; Lukas, Timothy
2013-02-01
This is a study to fully assess a commercially available co-processed mannitol for its usefulness as an off-the-shelf excipient for developing orally disintegrating tablets (ODTs) by direct compression on a pilot scale (up to 4 kg). This work encompassed material characterization, formulation optimisation and process robustness. Overall, this co-processed mannitol possessed favourable physical attributes including low hygroscopicity and compactibility. Two design-of-experiments (DoEs) were used to screen and optimise the placebo formulation. Xylitol and crospovidone concentrations were found to have the most significant impact on disintegration time (p < 0.05). Higher xylitol concentrations retarded disintegration. Avicel PH102 promoted faster disintegration than PH101, at higher levels of xylitol. Without xylitol, higher crospovidone concentrations yielded faster disintegration and reduced tablet friability. Lubrication sensitivity studies were later conducted at two fill loads, three levels for lubricant concentration and number of blend rotations. Even at 75% fill load, the design space plot showed that 1.5% lubricant and 300 blend revolutions were sufficient to manufacture ODTs with ≤ 0.1% friability and disintegrated within 15 s. This study also describes results using a modified disintegration method based on the texture analyzer as an alternative to the USP method.
The relative importance of patient-reported barriers to colorectal cancer screening.
Jones, Resa M; Woolf, Steven H; Cunningham, Tina D; Johnson, Robert E; Krist, Alex H; Rothemich, Stephen F; Vernon, Sally W
2010-05-01
Colorectal cancer (CRC) screening rates are suboptimal. The most important barriers identified by patients are poorly understood. A comprehensive assessment of barriers to all recommended modalities is needed. In 2007, a questionnaire was mailed to 6100 patients, aged 50-75 years, from 12 family medicine practices in the Virginia Ambulatory Care Outcomes Research Network. People aged 65-75 years and African Americans were oversampled. Patients were asked to rate 19-21 barriers to each of four recommended tests. In 2008, responses were coded on a 5-point scale; higher scores reflected stronger barrier endorsement. The response rate was 55% (n=3357). Approximately 40% of respondents were aged >/=65 years, 30% were African-American, and 73% were adherent to screening. A clinician's failure to suggest screening and not knowing testing was necessary received the highest mean scores as barriers. Financial concerns and misconceptions were also cited. Barrier scores differed depending on whether respondents were never screened, overdue for screening, or adherent to guidelines. The top five barriers for each modality included test-specific barriers (e.g., handling stool, bowel preparation), which often outranked generic barriers to screening. Not knowing testing was necessary was a top barrier for all tests but colonoscopy. Although physician advice and awareness of the need for screening are important, barriers to screening are not homogenous across tests, and test-specific barriers warrant consideration in designing strategies to improve screening rates. Barrier scores differ by screening status, highlighting the need to address prior screening experience. Evidence that patients are more familiar with colonoscopy than with other modalities suggests an opportunity to improve screening rates by educating patients about alternative tests. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Cost-effectiveness of digital mammography screening before the age of 50 in The Netherlands.
Sankatsing, Valérie D V; Heijnsdijk, Eveline A M; van Luijt, Paula A; van Ravesteyn, Nicolien T; Fracheboud, Jacques; de Koning, Harry J
2015-10-15
In the Netherlands, routine mammography screening starts at age 50. This starting age may have to be reconsidered because of the increasing breast cancer incidence among women aged 40 to 49 and the recent implementation of digital mammography. We assessed the cost-effectiveness of digital mammography screening that starts between age 40 and 49, using a microsimulation model. Women were screened before age 50, in addition to the current programme (biennial 50-74). Screening strategies varied in starting age (between 40 and 50) and frequency (annual or biennial). The numbers of breast cancers diagnosed, life-years gained (LYG) and breast cancer deaths averted were predicted and incremental cost-effectiveness ratios (ICERs) were calculated to compare screening scenarios. Biennial screening from age 50 to 74 (current strategy) was estimated to gain 157 life years per 1,000 women with lifelong follow-up, compared to a situation without screening, and cost €3,376/LYG (3.5% discounted). Additional screening increased the number of LYG, compared to no screening, ranging from 168 to 242. The costs to generate one additional LYG (i.e., ICER), comparing a screening strategy to the less intensive alternative, were estimated at €5,329 (biennial 48-74 vs. current strategy), €7,628 (biennial 45-74 vs. biennial 48-74), €10,826 (biennial 40-74 vs. biennial 45-74) and €18,759 (annual 40-49 + biennial 50-74 vs. biennial 40-74). Other strategies (49 + biennial 50-74 and annual 45-49 + biennial 50-74) resulted in less favourable ICERs. These findings show that extending the Dutch screening programme by screening between age 40 and 49 is cost-effective, particularly for biennial strategies. © 2015 UICC.