Sample records for process management bpm

  1. BPM 3.0

    NASA Astrophysics Data System (ADS)

    Scheer, August-Wilhelm; Klueckmann, Joerg

    Business Process Management (BPM) is an established management discipline. Since today’s organizations expect every employee to think and act like an entrepreneur, i.e., like a manager, BPM is also increasingly becoming part of everyday operations. But merely adopting a process-based approach across the enterprise is not enough to enable BPM at every level. What is needed is a combination of organizational forms and technologies that support distributed BPM initiatives while simultaneously consolidating them company-wide. Every employee must be empowered to model and optimize their own processes. At the same time, the entire BPM community needs a platform that brings together all the individual initiatives. This is the only way to leverage the full potential of process-oriented management. In the following article, the authors describe the trends in BPM development that are turning users into process managers and supporting the creation of a BPM community.

  2. Developing cloud-based Business Process Management (BPM): a survey

    NASA Astrophysics Data System (ADS)

    Mercia; Gunawan, W.; Fajar, A. N.; Alianto, H.; Inayatulloh

    2018-03-01

    In today’s highly competitive business environment, modern enterprises are dealing difficulties to cut unnecessary costs, eliminate wastes and delivery huge benefits for the organization. Companies are increasingly turning to a more flexible IT environment to help them realize this goal. For this reason, the article applies cloud based Business Process Management (BPM) that enables to focus on modeling, monitoring and process management. Cloud based BPM consists of business processes, business information and IT resources, which help build real-time intelligence systems, based on business management and cloud technology. Cloud computing is a paradigm that involves procuring dynamically measurable resources over the internet as an IT resource service. Cloud based BPM service enables to address common problems faced by traditional BPM, especially in promoting flexibility, event-driven business process to exploit opportunities in the marketplace.

  3. Process-aware EHR BPM systems: two prototypes and a conceptual framework.

    PubMed

    Webster, Charles; Copenhaver, Mark

    2010-01-01

    Systematic methods to improve the effectiveness and efficiency of electronic health record-mediated processes will be key to EHRs playing an important role in the positive transformation of healthcare. Business process management (BPM) systematically optimizes process effectiveness, efficiency, and flexibility. Therefore BPM offers relevant ideas and technologies. We provide a conceptual model based on EHR productivity and negative feedback control that links EHR and BPM domains, describe two EHR BPM prototype modules, and close with the argument that typical EHRs must become more process-aware if they are to take full advantage of BPM ideas and technology. A prediction: Future extensible clinical groupware will coordinate delivery of EHR functionality to teams of users by combining modular components with executable process models whose usability (effectiveness, efficiency, and user satisfaction) will be systematically improved using business process management techniques.

  4. Service Contract Compliance Management in Business Process Management

    NASA Astrophysics Data System (ADS)

    El Kharbili, Marwane; Pulvermueller, Elke

    Compliance management is a critical concern for corporations, required to respect contracts. This concern is particularly relevant in the context of business process management (BPM) as this paradigm is getting adopted more widely for-designing and building IT systems. Enforcing contractual compliance needs to be modeled at different levels of a BPM framework, which also includes the service layer. In this paper, we discuss requirements and methods for modeling contractual compliance for an SOA-supported BPM. We also show how business rule management integrated into an industry BPM tool allows modeling and processing functional and non-functional-property constraints which may be extracted from business process contracts. This work proposes a framework that responds to the requirements identified and proposes an architecture implementing it. Our approach is also illustrated by an example.

  5. Towards a typology of business process management professionals: identifying patterns of competences through latent semantic analysis

    NASA Astrophysics Data System (ADS)

    Müller, Oliver; Schmiedel, Theresa; Gorbacheva, Elena; vom Brocke, Jan

    2016-01-01

    While researchers have analysed the organisational competences that are required for successful Business Process Management (BPM) initiatives, individual BPM competences have not yet been studied in detail. In this study, latent semantic analysis is used to examine a collection of 1507 BPM-related job advertisements in order to develop a typology of BPM professionals. This empirical analysis reveals distinct ideal types and profiles of BPM professionals on several levels of abstraction. A closer look at these ideal types and profiles confirms that BPM is a boundary-spanning field that requires interdisciplinary sets of competence that range from technical competences to business and systems competences. Based on the study's findings, it is posited that individual and organisational alignment with the identified ideal types and profiles is likely to result in high employability and organisational BPM success.

  6. Improvement of hospital processes through business process management in Qaem Teaching Hospital: A work in progress.

    PubMed

    Yarmohammadian, Mohammad H; Ebrahimipour, Hossein; Doosty, Farzaneh

    2014-01-01

    In a world of continuously changing business environments, organizations have no option; however, to deal with such a big level of transformation in order to adjust the consequential demands. Therefore, many companies need to continually improve and review their processes to maintain their competitive advantages in an uncertain environment. Meeting these challenges requires implementing the most efficient possible business processes, geared to the needs of the industry and market segments that the organization serves globally. In the last 10 years, total quality management, business process reengineering, and business process management (BPM) have been some of the management tools applied by organizations to increase business competiveness. This paper is an original article that presents implementation of "BPM" approach in the healthcare domain that allows an organization to improve and review its critical business processes. This project was performed in "Qaem Teaching Hospital" in Mashhad city, Iran and consists of four distinct steps; (1) identify business processes, (2) document the process, (3) analyze and measure the process, and (4) improve the process. Implementing BPM in Qaem Teaching Hospital changed the nature of management by allowing the organization to avoid the complexity of disparate, soloed systems. BPM instead enabled the organization to focus on business processes at a higher level.

  7. Notification Event Architecture for Traveler Screening: Predictive Traveler Screening Using Event Driven Business Process Management

    ERIC Educational Resources Information Center

    Lynch, John Kenneth

    2013-01-01

    Using an exploratory model of the 9/11 terrorists, this research investigates the linkages between Event Driven Business Process Management (edBPM) and decision making. Although the literature on the role of technology in efficient and effective decision making is extensive, research has yet to quantify the benefit of using edBPM to aid the…

  8. Extending BPM Environments of Your Choice with Performance Related Decision Support

    NASA Astrophysics Data System (ADS)

    Fritzsche, Mathias; Picht, Michael; Gilani, Wasif; Spence, Ivor; Brown, John; Kilpatrick, Peter

    What-if Simulations have been identified as one solution for business performance related decision support. Such support is especially useful in cases where it can be automatically generated out of Business Process Management (BPM) Environments from the existing business process models and performance parameters monitored from the executed business process instances. Currently, some of the available BPM Environments offer basic-level performance prediction capabilities. However, these functionalities are normally too limited to be generally useful for performance related decision support at business process level. In this paper, an approach is presented which allows the non-intrusive integration of sophisticated tooling for what-if simulations, analytic performance prediction tools, process optimizations or a combination of such solutions into already existing BPM environments. The approach abstracts from process modelling techniques which enable automatic decision support spanning processes across numerous BPM Environments. For instance, this enables end-to-end decision support for composite processes modelled with the Business Process Modelling Notation (BPMN) on top of existing Enterprise Resource Planning (ERP) processes modelled with proprietary languages.

  9. Democratizing Process Innovation? On Citizen Involvement in Public Sector BPM

    NASA Astrophysics Data System (ADS)

    Niehaves, Björn; Malsch, Robert

    ‘Open Innovation’ has been heavily discussed for product innovations; however, an information systems (IS) perspective on ‘process innovation’ has not yet been taken. Analyzing the example of the public sector in Germany, the paper seeks to investigate the factors that hinder and support ‘open process innovation’, a concept we define as the involvement of citizens in business process management (BPM) activities. With the help of a quantitative study (n=358), six factors are examined for their impact on citizen involvement in local government BPM initiatives. The results show that citizen involvement in reform processes is not primarily motivated by the aim of cost reduction, but rather related to legitimacy reasons and the intent to increase employee motivation. Based on these findings, implications for (design) theory and practice are discussed: Instead of detailed collaborative business processes modeling, the key of citizen involvement in public sector BPM lies in communication and mutual understanding.

  10. Towards an Understanding of the Business Process Analyst: An Analysis of Competencies

    ERIC Educational Resources Information Center

    Sonteya, Thembela; Seymour, Lisa

    2012-01-01

    The increase in adoption of business process management (BPM) and service oriented architecture (SOA) has created a high demand for qualified professionals with a plethora of skills. However, despite the growing amount of literature available on the topics of BPM and SOA, little research has been conducted around developing a detailed list of…

  11. Common Workflow Service: Standards Based Solution for Managing Operational Processes

    NASA Astrophysics Data System (ADS)

    Tinio, A. W.; Hollins, G. A.

    2017-06-01

    The Common Workflow Service is a collaborative and standards-based solution for managing mission operations processes using techniques from the Business Process Management (BPM) discipline. This presentation describes the CWS and its benefits.

  12. The Tail of BPM

    NASA Astrophysics Data System (ADS)

    Kruba, Steve; Meyer, Jim

    Business process management suites (BPMS's) represent one of the fastest growing segments in the software industry as organizations automate their key business processes. As this market matures, it is interesting to compare it to Chris Anderson's 'Long Tail.' Although the 2004 "Long Tail" article in Wired magazine was primarily about the media and entertainment industries, it has since been applied (and perhaps misapplied) to other markets. Analysts describe a "Tail of BPM" market that is, perhaps, several times larger than the traditional BPMS product market. This paper will draw comparisons between the concepts in Anderson's article (and subsequent book) and the BPM solutions market.

  13. Ontology-based approaches for cross-enterprise collaboration: a literature review on semantic business process management

    NASA Astrophysics Data System (ADS)

    Hoang, Hanh H.; Jung, Jason J.; Tran, Chi P.

    2014-11-01

    Based on an in-depth analysis of the existing approaches in applying semantic technologies to business process management (BPM) research in the perspective of cross-enterprise collaboration or so-called business-to-business integration, we analyse, discuss and compare methodologies, applications and best practices of the surveyed approaches with the proposed criteria. This article identifies various relevant research directions in semantic BPM (SBPM). Founded on the result of our investigation, we summarise the state of art of SBPM. We also address areas and directions for further research activities.

  14. Application fields for the new Object Management Group (OMG) Standards Case Management Model and Notation (CMMN) and Decision Management Notation (DMN) in the perioperative field.

    PubMed

    Wiemuth, M; Junger, D; Leitritz, M A; Neumann, J; Neumuth, T; Burgert, O

    2017-08-01

    Medical processes can be modeled using different methods and notations. Currently used modeling systems like Business Process Model and Notation (BPMN) are not capable of describing the highly flexible and variable medical processes in sufficient detail. We combined two modeling systems, Business Process Management (BPM) and Adaptive Case Management (ACM), to be able to model non-deterministic medical processes. We used the new Standards Case Management Model and Notation (CMMN) and Decision Management Notation (DMN). First, we explain how CMMN, DMN and BPMN could be used to model non-deterministic medical processes. We applied this methodology to model 79 cataract operations provided by University Hospital Leipzig, Germany, and four cataract operations provided by University Eye Hospital Tuebingen, Germany. Our model consists of 85 tasks and about 20 decisions in BPMN. We were able to expand the system with more complex situations that might appear during an intervention. An effective modeling of the cataract intervention is possible using the combination of BPM and ACM. The combination gives the possibility to depict complex processes with complex decisions. This combination allows a significant advantage for modeling perioperative processes.

  15. Teaching Business Process Management with Simulation in Graduate Business Programs: An Integrative Approach

    ERIC Educational Resources Information Center

    Saraswat, Satya Prakash; Anderson, Dennis M.; Chircu, Alina M.

    2014-01-01

    This paper describes the development and evaluation of a graduate level Business Process Management (BPM) course with process modeling and simulation as its integral component, being offered at an accredited business university in the Northeastern U.S. Our approach is similar to that found in other Information Systems (IS) education papers, and…

  16. Enabling Healthcare IT Governance: Human Task Management Service for Administering Emergency Department's Resources for Efficient Patient Flow.

    PubMed

    Rodriguez, Salvador; Aziz, Ayesha; Chatwin, Chris

    2014-01-01

    The use of Health Information Technology (HIT) to improve healthcare service delivery is constantly increasing due to research advances in medical science and information systems. Having a fully automated process solution for a Healthcare Organization (HCO) requires a combination of organizational strategies along with a selection of technologies that facilitate the goal of improving clinical outcomes. HCOs, requires dynamic management of care capability to realize the full potential of HIT. Business Process Management (BPM) is being increasingly adopted to streamline the healthcare service delivery and management processes. Emergency Departments (EDs) provide a case in point, which require multidisciplinary resources and services to deliver effective clinical outcomes. Managed care involves the coordination of a range of services in an ED. Although fully automated processes in emergency care provide a cutting edge example of service delivery, there are many situations that require human interactions with the computerized systems; e.g. Medication Approvals, care transfer, acute patient care. This requires a coordination mechanism for all the resources, computer and human, to work side by side to provide the best care. To ensure evidence-based medical practice in ED, we have designed a Human Task Management service to model the process of coordination of ED resources based on the UK's NICE Clinical guideline for managing the care of acutely ill patients. This functionality is implemented using Java Business process Management (jBPM).

  17. Improved compliance by BPM-driven workflow automation.

    PubMed

    Holzmüller-Laue, Silke; Göde, Bernd; Fleischer, Heidi; Thurow, Kerstin

    2014-12-01

    Using methods and technologies of business process management (BPM) for the laboratory automation has important benefits (i.e., the agility of high-level automation processes, rapid interdisciplinary prototyping and implementation of laboratory tasks and procedures, and efficient real-time process documentation). A principal goal of the model-driven development is the improved transparency of processes and the alignment of process diagrams and technical code. First experiences of using the business process model and notation (BPMN) show that easy-to-read graphical process models can achieve and provide standardization of laboratory workflows. The model-based development allows one to change processes quickly and an easy adaption to changing requirements. The process models are able to host work procedures and their scheduling in compliance with predefined guidelines and policies. Finally, the process-controlled documentation of complex workflow results addresses modern laboratory needs of quality assurance. BPMN 2.0 as an automation language to control every kind of activity or subprocess is directed to complete workflows in end-to-end relationships. BPMN is applicable as a system-independent and cross-disciplinary graphical language to document all methods in laboratories (i.e., screening procedures or analytical processes). That means, with the BPM standard, a communication method of sharing process knowledge of laboratories is also available. © 2014 Society for Laboratory Automation and Screening.

  18. An Information System Development Method Connecting Business Process Modeling and its Experimental Evaluation

    NASA Astrophysics Data System (ADS)

    Okawa, Tsutomu; Kaminishi, Tsukasa; Kojima, Yoshiyuki; Hirabayashi, Syuichi; Koizumi, Hisao

    Business process modeling (BPM) is gaining attention as a measure of analysis and improvement of the business process. BPM analyses the current business process as an AS-IS model and solves problems to improve the current business and moreover it aims to create a business process, which produces values, as a TO-BE model. However, researches of techniques that connect the business process improvement acquired by BPM to the implementation of the information system seamlessly are rarely reported. If the business model obtained by BPM is converted into UML, and the implementation can be carried out by the technique of UML, we can expect the improvement in efficiency of information system implementation. In this paper, we describe a method of the system development, which converts the process model obtained by BPM into UML and the method is evaluated by modeling a prototype of a parts procurement system. In the evaluation, comparison with the case where the system is implemented by the conventional UML technique without going via BPM is performed.

  19. An Information System Development Method Combining Business Process Modeling with Executable Modeling and its Evaluation by Prototyping

    NASA Astrophysics Data System (ADS)

    Okawa, Tsutomu; Kaminishi, Tsukasa; Hirabayashi, Syuichi; Suzuki, Ryo; Mitsui, Hiroyasu; Koizumi, Hisao

    The business in the enterprise is closely related with the information system to such an extent that the business activities are difficult without the information system. The system design technique that considers the business process well, and that enables a quick system development is requested. In addition, the demand for the development cost is also severe than before. To cope with the current situation, the modeling technology named BPM(Business Process Management/Modeling)is drawing attention and becoming important as a key technology. BPM is a technology to model business activities as business processes and visualize them to improve the business efficiency. However, a general methodology to develop the information system using the analysis result of BPM doesn't exist, and a few development cases are reported. This paper proposes an information system development method combining business process modeling with executable modeling. In this paper we describe a guideline to support consistency of development and development efficiency and the framework enabling to develop the information system from model. We have prototyped the information system with the proposed method and our experience has shown that the methodology is valuable.

  20. A methodology proposal for collaborative business process elaboration using a model-driven approach

    NASA Astrophysics Data System (ADS)

    Mu, Wenxin; Bénaben, Frédérick; Pingaud, Hervé

    2015-05-01

    Business process management (BPM) principles are commonly used to improve processes within an organisation. But they can equally be applied to supporting the design of an Information System (IS). In a collaborative situation involving several partners, this type of BPM approach may be useful to support the design of a Mediation Information System (MIS), which would ensure interoperability between the partners' ISs (which are assumed to be service oriented). To achieve this objective, the first main task is to build a collaborative business process cartography. The aim of this article is to present a method for bringing together collaborative information and elaborating collaborative business processes from the information gathered (by using a collaborative situation framework, an organisational model, an informational model, a functional model and a metamodel and by using model transformation rules).

  1. Interplay between Clinical Guidelines and Organizational Workflow Systems. Experience from the MobiGuide Project.

    PubMed

    Shabo, Amnon; Peleg, Mor; Parimbelli, Enea; Quaglini, Silvana; Napolitano, Carlo

    2016-12-07

    Implementing a decision-support system within a healthcare organization requires integration of clinical domain knowledge with resource constraints. Computer-interpretable guidelines (CIG) are excellent instruments for addressing clinical aspects while business process management (BPM) languages and Workflow (Wf) engines manage the logistic organizational constraints. Our objective is the orchestration of all the relevant factors needed for a successful execution of patient's care pathways, especially when spanning the continuum of care, from acute to community or home care. We considered three strategies for integrating CIGs with organizational workflows: extending the CIG or BPM languages and their engines, or creating an interplay between them. We used the interplay approach to implement a set of use cases arising from a CIG implementation in the domain of Atrial Fibrillation. To provide a more scalable and standards-based solution, we explored the use of Cross-Enterprise Document Workflow Integration Profile. We describe our proof-of-concept implementation of five use cases. We utilized the Personal Health Record of the MobiGuide project to implement a loosely-coupled approach between the Activiti BPM engine and the Picard CIG engine. Changes in the PHR were detected by polling. IHE profiles were used to develop workflow documents that orchestrate cross-enterprise execution of cardioversion. Interplay between CIG and BPM engines can support orchestration of care flows within organizational settings.

  2. A pivotal-based approach for enterprise business process and IS integration

    NASA Astrophysics Data System (ADS)

    Ulmer, Jean-Stéphane; Belaud, Jean-Pierre; Le Lann, Jean-Marc

    2013-02-01

    A company must be able to describe and react against any endogenous or exogenous event. Such flexibility can be achieved through business process management (BPM). Nevertheless a BPM approach highlights complex relations between business and IT domains. A non-alignment is exposed between heterogeneous models: this is the 'business-IT gap' as described in the literature. Through concepts from business engineering and information systems driven by models and IT, we define a generic approach ensuring multi-view consistency. Its role is to maintain and provide all information related to the structure and semantic of models. Allowing the full return of a transformed model in the sense of reverse engineering, our platform enables synchronisation between analysis model and implementation model.

  3. Potential of Laboratory Execution Systems (LESs) to Simplify the Application of Business Process Management Systems (BPMSs) in Laboratory Automation.

    PubMed

    Neubert, Sebastian; Göde, Bernd; Gu, Xiangyu; Stoll, Norbert; Thurow, Kerstin

    2017-04-01

    Modern business process management (BPM) is increasingly interesting for laboratory automation. End-to-end workflow automation and improved top-level systems integration for information technology (IT) and automation systems are especially prominent objectives. With the ISO Standard Business Process Model and Notation (BPMN) 2.X, a system-independent and interdisciplinary accepted graphical process control notation is provided, allowing process analysis, while also being executable. The transfer of BPM solutions to structured laboratory automation places novel demands, for example, concerning the real-time-critical process and systems integration. The article discusses the potential of laboratory execution systems (LESs) for an easier implementation of the business process management system (BPMS) in hierarchical laboratory automation. In particular, complex application scenarios, including long process chains based on, for example, several distributed automation islands and mobile laboratory robots for a material transport, are difficult to handle in BPMSs. The presented approach deals with the displacement of workflow control tasks into life science specialized LESs, the reduction of numerous different interfaces between BPMSs and subsystems, and the simplification of complex process modelings. Thus, the integration effort for complex laboratory workflows can be significantly reduced for strictly structured automation solutions. An example application, consisting of a mixture of manual and automated subprocesses, is demonstrated by the presented BPMS-LES approach.

  4. BPM System for Electron Cooling in the Fermilab Recycler Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joireman, Paul W.; Cai, Jerry; Chase, Brian E.

    2004-11-10

    We report a VXI based system used to acquire and process BPM data for the electron cooling system in the Fermilab Recycler ring. The BPM system supports acquisition of data from 19 BPM locations in five different sections of the electron cooling apparatus. Beam positions for both electrons and anti-protons can be detected simultaneously with a resolution of {+-}50 {mu}m. We calibrate the system independently for each beam type at each BPM location. We describe the system components, signal processing and modes of operation used in support of the electron-cooling project and present experimental results of system performance for themore » developmental electron cooling installation at Fermilab.« less

  5. Scaffolding protein RanBPM and its interactions in diverse signaling pathways in health and disease.

    PubMed

    Das, Soumyadip; Haq, Saba; Ramakrishna, Suresh

    2018-04-01

    Ran-binding protein in the microtubule-organizing center (RanBPM) is an evolutionarily conserved, nucleocytoplasmic scaffolding protein involved in various cellular processes and several signal transduction pathways. RanBPM has a crucial role in mediating disease pathology by interacting with diverse proteins to regulate their functions. Previously, we compiled diverse cellular functions of RanBPM. Since then the functions of RanBPM have increased exponentially. In this article, we have updated the functions of RanBPM through its manifold interactions that have been investigated to date, according to their roles in protein stability, transcriptional activity, cellular development, neurobiology, and the cell cycle. Our review provides a complete guide on RanBPM interactors, the physiological role of RanBPM in cellular functions, and potential applications in disease therapeutics.

  6. Ontological Model of Business Process Management Systems

    NASA Astrophysics Data System (ADS)

    Manoilov, G.; Deliiska, B.

    2008-10-01

    The activities which constitute business process management (BPM) can be grouped into five categories: design, modeling, execution, monitoring and optimization. Dedicated software packets for business process management system (BPMS) are available on the market. But the efficiency of its exploitation depends on used ontological model in the development time and run time of the system. In the article an ontological model of BPMS in area of software industry is investigated. The model building is preceded by conceptualization of the domain and taxonomy of BPMS development. On the base of the taxonomy an simple online thesaurus is created.

  7. New methods for clinical pathways-Business Process Modeling Notation (BPMN) and Tangible Business Process Modeling (t.BPM).

    PubMed

    Scheuerlein, Hubert; Rauchfuss, Falk; Dittmar, Yves; Molle, Rüdiger; Lehmann, Torsten; Pienkos, Nicole; Settmacher, Utz

    2012-06-01

    Clinical pathways (CP) are nowadays used in numerous institutions, but their real impact is still a matter of debate. The optimal design of a clinical pathway remains unclear and is mainly determined by the expectations of the individual institution. The purpose of the here described pilot project was the development of two CP (colon and rectum carcinoma) according to Business Process Modeling Notation (BPMN) and Tangible Business Process Modeling (t.BPM). BPMN is an established standard for business process modelling in industry and economy. It is, in the broadest sense, a computer programme which enables the description and a relatively easy graphical imaging of complex processes. t.BPM is a modular construction system of the BPMN symbols which enables the creation of an outline or raw model, e.g. by placing the symbols on a spread-out paper sheet. The thus created outline can then be transferred to the computer and further modified as required. CP for the treatment of colon and rectal cancer have been developed with support of an external IT coach. The pathway was developed in an interdisciplinary and interprofessional manner (55 man-days over 15 working days). During this time, necessary interviews with medical, nursing and administrative staffs were conducted as well. Both pathways were developed parallel. Subsequent analysis was focussed on feasibility, expenditure, clarity and suitability for daily clinical practice. The familiarization with BPMN was relatively quick and intuitive. The use of t.BPM enabled the pragmatic, effective and results-directed creation of outlines for the CP. The development of both CP was finished from the diagnostic evaluation to the adjuvant/neoadjuvant therapy and rehabilitation phase. The integration of checklists, guidelines and important medical or other documents is easily accomplished. A direct integration into the hospital computer system is currently not possible for technical reasons. BPMN and t.BPM are sufficiently suitable for the planned modelling and imaging of CP. The application in medicine is new, and transfer from the industrial process management is in principle possible. BPMN-CP may be used for teaching and training, patient information and quality management. The graphical image is clearly structured and appealing. Even though the efficiency in the creation of BPMN-CP increases markedly after the training phase, high amounts of manpower and time are required. The most sensible and consequent application of a BPMN-CP would be the direct integration into the hospital computer system. The integration of a modelling language, such as BPMN, into the hospital computer systems could be a very sensible approach for the development of new hospital information systems in the future.

  8. A literature review on business process modelling: new frontiers of reusability

    NASA Astrophysics Data System (ADS)

    Aldin, Laden; de Cesare, Sergio

    2011-08-01

    Business process modelling (BPM) has become fundamental for modern enterprises due to the increasing rate of organisational change. As a consequence, business processes need to be continuously (re-)designed as well as subsequently aligned with the corresponding enterprise information systems. One major problem associated with the design of business processes is reusability. Reuse of business process models has the potential of increasing the efficiency and effectiveness of BPM. This article critically surveys the existing literature on the problem of BPM reusability and more specifically on that State-of-the-Art research that can provide or suggest the 'elements' required for the development of a methodology aimed at discovering reusable conceptual artefacts in the form of patterns. The article initially clarifies the definitions of business process and business process model; then, it sets out to explore the previous research conducted in areas that have an impact on reusability in BPM. The article concludes by distilling directions for future research towards the development of apatterns-based approach to BPM; an approach that brings together the contributions made by the research community in the areas of process mining and discovery, declarative approaches and ontologies.

  9. Advances in industrial biopharmaceutical batch process monitoring: Machine-learning methods for small data problems.

    PubMed

    Tulsyan, Aditya; Garvin, Christopher; Ündey, Cenk

    2018-04-06

    Biopharmaceutical manufacturing comprises of multiple distinct processing steps that require effective and efficient monitoring of many variables simultaneously in real-time. The state-of-the-art real-time multivariate statistical batch process monitoring (BPM) platforms have been in use in recent years to ensure comprehensive monitoring is in place as a complementary tool for continued process verification to detect weak signals. This article addresses a longstanding, industry-wide problem in BPM, referred to as the "Low-N" problem, wherein a product has a limited production history. The current best industrial practice to address the Low-N problem is to switch from a multivariate to a univariate BPM, until sufficient product history is available to build and deploy a multivariate BPM platform. Every batch run without a robust multivariate BPM platform poses risk of not detecting potential weak signals developing in the process that might have an impact on process and product performance. In this article, we propose an approach to solve the Low-N problem by generating an arbitrarily large number of in silico batches through a combination of hardware exploitation and machine-learning methods. To the best of authors' knowledge, this is the first article to provide a solution to the Low-N problem in biopharmaceutical manufacturing using machine-learning methods. Several industrial case studies from bulk drug substance manufacturing are presented to demonstrate the efficacy of the proposed approach for BPM under various Low-N scenarios. © 2018 Wiley Periodicals, Inc.

  10. Validation of PEP-II Resonantly Excited Turn-by-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Yiton T.; Cai, Yunhai; Colocho, William.

    2007-06-28

    For optics measurement and modeling of the PEP-II electron (HER) and position (LER) storage rings, we have been doing well with MIA [1] which requires analyzing turn-by-turn Beam Position Monitor (BPM) data that are resonantly excited at the horizontal, vertical, and longitudinal tunes. However, in anticipation that certain BPM buttons and even pins in the PEP-II IR region would be missing for the run starting in January 2007, we had been developing a data validation process to reduce the effect due to the reduced BPM data accuracy on PEP-II optics measurement and modeling. Besides the routine process for ranking BPMmore » noise level through data correlation among BPMs with a singular-value decomposition (SVD), we could also check BPM data symplecticity by comparing the invariant ratios. Results from PEP-II measurement will be presented.« less

  11. Educating Information Systems Students on Business Process Management (BPM) through Digital Gaming Metaphors of Virtual Reality

    ERIC Educational Resources Information Center

    Lawler, James P.; Joseph, Anthony

    2010-01-01

    Digital gaming continues to be an approach for enhancing methods of pedagogy. The study evaluates the effectiveness of a gaming product of a leading technology firm in engaging graduate students in an information systems course at a major northeast institution. Findings from a detailed perception survey of the students indicate favorable…

  12. Design and performance of the LCLS cavity BPM system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Norum, E.; Morrison, L.

    2008-01-01

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low- noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  13. Design and Performance of the LCLS Cavity BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.M.; Morrison, L.H.; Norum, W.E.

    2008-01-23

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  14. Digital signal processing the Tevatron BPM signals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cancelo, G.; James, E.; Wolbers, S.

    2005-05-01

    The Beam Position Monitor (TeV BPM) readout system at Fermilab's Tevatron has been updated and is currently being commissioned. The new BPMs use new analog and digital hardware to achieve better beam position measurement resolution. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiproton measurements. The signals provided by the two ends of the BPM pickups are processed by analog band-pass filters and sampled by 14-bit ADCs at 74.3MHz. A crucial part of this work has been the design of digital filters that process the signal. This paper describesmore » the digital processing and estimation techniques used to optimize the beam position measurement. The BPM electronics must operate in narrow-band and wide-band modes to enable measurements of closed-orbit and turn-by-turn positions. The filtering and timing conditions of the signals are tuned accordingly for the operational modes. The analysis and the optimized result for each mode are presented.« less

  15. Multicriteria framework for selecting a process modelling language

    NASA Astrophysics Data System (ADS)

    Scanavachi Moreira Campos, Ana Carolina; Teixeira de Almeida, Adiel

    2016-01-01

    The choice of process modelling language can affect business process management (BPM) since each modelling language shows different features of a given process and may limit the ways in which a process can be described and analysed. However, choosing the appropriate modelling language for process modelling has become a difficult task because of the availability of a large number modelling languages and also due to the lack of guidelines on evaluating, and comparing languages so as to assist in selecting the most appropriate one. This paper proposes a framework for selecting a modelling language in accordance with the purposes of modelling. This framework is based on the semiotic quality framework (SEQUAL) for evaluating process modelling languages and a multicriteria decision aid (MCDA) approach in order to select the most appropriate language for BPM. This study does not attempt to set out new forms of assessment and evaluation criteria, but does attempt to demonstrate how two existing approaches can be combined so as to solve the problem of selection of modelling language. The framework is described in this paper and then demonstrated by means of an example. Finally, the advantages and disadvantages of using SEQUAL and MCDA in an integrated manner are discussed.

  16. The RiverFish Approach to Business Process Modeling: Linking Business Steps to Control-Flow Patterns

    NASA Astrophysics Data System (ADS)

    Zuliane, Devanir; Oikawa, Marcio K.; Malkowski, Simon; Alcazar, José Perez; Ferreira, João Eduardo

    Despite the recent advances in the area of Business Process Management (BPM), today’s business processes have largely been implemented without clearly defined conceptual modeling. This results in growing difficulties for identification, maintenance, and reuse of rules, processes, and control-flow patterns. To mitigate these problems in future implementations, we propose a new approach to business process modeling using conceptual schemas, which represent hierarchies of concepts for rules and processes shared among collaborating information systems. This methodology bridges the gap between conceptual model description and identification of actual control-flow patterns for workflow implementation. We identify modeling guidelines that are characterized by clear phase separation, step-by-step execution, and process building through diagrams and tables. The separation of business process modeling in seven mutually exclusive phases clearly delimits information technology from business expertise. The sequential execution of these phases leads to the step-by-step creation of complex control-flow graphs. The process model is refined through intuitive table and diagram generation in each phase. Not only does the rigorous application of our modeling framework minimize the impact of rule and process changes, but it also facilitates the identification and maintenance of control-flow patterns in BPM-based information system architectures.

  17. Status of the ATF Damping Ring BPM Upgrade Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briegel, C.; /Fermilab; Eddy, N.

    2011-12-01

    A substantial upgrade of the beam position monitors (BPM) at the ATF (Accelerator Test Facility) damping ring is currently in progress. Implementing digital read-out signal processing techniques in line with an optimized, low-noise analog downconverter, a resolution well below 1 mum could be demonstrated at 20 (of 96) upgraded BPM stations. The narrowband, high resolution BPM mode permits investigation of all types of non-linearities, imperfections and other obstacles in the machine which may limit the very low target aimed vertical beam emittance of < 2 pm. The technical status of the project, first beam measurements and an outlook to it'smore » finalization are presented.« less

  18. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  19. Spinal Cord Injury Impairs Cardiovascular Capacity in Elite Wheelchair Rugby Athletes.

    PubMed

    Gee, Cameron M; Currie, Katharine D; Phillips, Aaron A; Squair, Jordan W; Krassioukov, Andrei V

    2017-12-19

    To examine differences in heart rate (HR) responses during international wheelchair rugby competition between athletes with and without a cervical spinal cord injury (SCI) and across standardized sport classifications. Observational study. The 2015 Parapan American Games wheelchair rugby competition. Forty-three male athletes (31 ± 8 years) with a cervical SCI (n = 32) or tetraequivalent impairment (non-SCI, n = 11). Average and peak HR (HRavg and HRpeak, respectively). To characterize HR responses in accordance with an athletes' International Wheelchair Rugby Federation (IWRF) classification, we separated athletes into 3 groups: group I (IWRF classification 0.5-1.5, n = 15); group II (IWRF classification 2.0, n = 15); and group III (IWRF classification 2.5-3.5, n = 13). Athletes with SCI had lower HRavg (111 ± 14 bpm vs 155 ± 13 bpm) and HRpeak (133 ± 12 bpm vs 178 ± 13 bpm) compared with non-SCI (both P < 0.001). Average HR was higher in group III than in I (136 ± 25 bpm vs 115 ± 20 bpm, P = 0.045); however, SCI athletes showed no difference in HRavg or HRpeak between groups. Within group III, SCI athletes had lower HRavg (115 ± 6 bpm vs 160 ± 8 bpm) and HRpeak (135 ± 11 bpm vs 183 ± 11 bpm) than non-SCI athletes (both P < 0.001). This study is the first to demonstrate attenuated HR responses during competition in SCI compared with non-SCI athletes, likely due to injury to spinal autonomic pathways. Among athletes with SCI, IWRF classification was not related to differences in HR. Specific assessment of autonomic function after SCI may be able to predict HR during competition and consideration of autonomic impairments may improve the classification process.

  20. Statistical analysis of RHIC beam position monitors performance

    NASA Astrophysics Data System (ADS)

    Calaga, R.; Tomás, R.

    2004-04-01

    A detailed statistical analysis of beam position monitors (BPM) performance at RHIC is a critical factor in improving regular operations and future runs. Robust identification of malfunctioning BPMs plays an important role in any orbit or turn-by-turn analysis. Singular value decomposition and Fourier transform methods, which have evolved as powerful numerical techniques in signal processing, will aid in such identification from BPM data. This is the first attempt at RHIC to use a large set of data to statistically enhance the capability of these two techniques and determine BPM performance. A comparison from run 2003 data shows striking agreement between the two methods and hence can be used to improve BPM functioning at RHIC and possibly other accelerators.

  1. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    PubMed

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  2. Analog Signal Pre-Processing For The Fermilab Main Injector BPM Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, A. L.; Rapisarda, S. M.; Wendt, M.

    2006-11-20

    An analog signal pre-processing scheme was developed, in the framework of the Fermilab Main Injector Beam Position Monitor (BPM) Upgrade, to interface BPM pickup signals to the new digital receiver based read-out system. A key component is the 8-channel electronics module, which uses separate frequency-selective gain stages to acquire 53 MHz bunched proton and 2.5 MHz antiproton signals. Related hardware includes a filter and combiner box to sum pickup electrode signals in the tunnel. A controller module allows local/remote control of gain settings and activation of gain stages and supplies test signals. Theory of operation, system overview, and some designmore » details are presented, as well as first beam measurements of the prototype hardware.« less

  3. Surgical management of bronchopulmonary malformations.

    PubMed

    Wagenaar, Amy E; Tashiro, Jun; Hirzel, Alicia; Rodriguez, Luis I; Perez, Eduardo A; Hogan, Anthony R; Neville, Holly L; Sola, Juan E

    2015-10-01

    Bronchopulmonary malformations (BPM) are rare conditions, which typically arise below the carina and can result in significant morbidity (infection and/or hemorrhage) and mortality (respiratory failure). All children with BPM surgically treated from 2001-2014 at a tertiary care children's hospital were identified. Patient demographics, surgical indications, procedure type, estimated blood loss, pathology, perioperative complications, length of stay, and outcomes were analyzed. A total of 41 BPM patients underwent surgery with 98% overall survival (one abdominal BPM expired) but 100% for thoracic lesions. Resections were performed thoracoscopically (37%), thoracoscopy converted to open (22%), and via thoracotomy (37%). Poor visualization (67%) or inability to tolerate single lung ventilation (33%) led to conversions. No conversions resulted from hemorrhage or received blood transfusions. Patients with prenatally diagnosed BPM were more likely to undergo thoracoscopic surgery (odds ratio [OR], 18.2) versus nonprenatally diagnosed, P = 0.002. Open/converted patients had longer chest tube days (6.2) versus thoracoscopic (2.9), P = 0.048. Additionally, respiratory distress was a more common indication in patients aged <4 mo (OR, 28.0) versus ≥4 mo and <6 kg (OR, 40.5) versus ≥6 kg, P < 0.001. Open resections were more common in patients aged <4 mo (OR, 26.3) versus ≥4 mo, P = 0.002. Operative time was shorter and estimated blood loss (mL/kg) was greater for <6 versus ≥6 kg, P < 0.05. BPM resections have high overall survival. Chest tube days are shorter among thoracoscopic patients, but conversion to thoracotomy can avoid hemorrhage and need for transfusion. Size and respiratory distress limit use of thoracoscopy in young infants with BPM. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. RHIC BPM SYSTEM MODIFICATIONS AND PERFORMANCE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SATOGATA, T.; CALAGA, R.; CAMERON, P.

    2005-05-16

    The RHIC beam position monitor (BPM) system provides independent average orbit and turn-by-turn (TBT) position measurements. In each ring, there are 162 measurement locations per plane (horizontal and vertical) for a total of 648 BPM planes in the RHIC machine. During 2003 and 2004 shutdowns, BPM processing electronics were moved from the RHIC tunnel to controls alcoves to reduce radiation impact, and the analog signal paths of several dozen modules were modified to eliminate gain-switching relays and improve signal stability. This paper presents results of improved system performance, including stability for interaction region beam-based alignment efforts. We also summarize performancemore » of recently-added DSP profile scan capability, and improved million-turn TBT acquisition channels for 10 Hz triplet vibration, nonlinear dynamics, and echo studies.« less

  5. Statistical baseline assessment in cardiotocography.

    PubMed

    Agostinelli, Angela; Braccili, Eleonora; Marchegiani, Enrico; Rosati, Riccardo; Sbrollini, Agnese; Burattini, Luca; Morettini, Micaela; Di Nardo, Francesco; Fioretti, Sandro; Burattini, Laura

    2017-07-01

    Cardiotocography (CTG) is the most common non-invasive diagnostic technique to evaluate fetal well-being. It consists in the recording of fetal heart rate (FHR; bpm) and maternal uterine contractions. Among the main parameters characterizing FHR, baseline (BL) is fundamental to determine fetal hypoxia and distress. In computerized applications, BL is typically computed as mean FHR±ΔFHR, with ΔFHR=8 bpm or ΔFHR=10 bpm, both values being experimentally fixed. In this context, the present work aims: to propose a statistical procedure for ΔFHR assessment; to quantitatively determine ΔFHR value by applying such procedure to clinical data; and to compare the statistically-determined ΔFHR value against the experimentally-determined ΔFHR values. To these aims, the 552 recordings of the "CTU-UHB intrapartum CTG database" from Physionet were submitted to an automatic procedure, which consisted in a FHR preprocessing phase and a statistical BL assessment. During preprocessing, FHR time series were divided into 20-min sliding windows, in which missing data were removed by linear interpolation. Only windows with a correction rate lower than 10% were further processed for BL assessment, according to which ΔFHR was computed as FHR standard deviation. Total number of accepted windows was 1192 (38.5%) over 383 recordings (69.4%) with at least an accepted window. Statistically-determined ΔFHR value was 9.7 bpm. Such value was statistically different from 8 bpm (P<;10 -19 ) but not from 10 bpm (P=0.16). Thus, ΔFHR=10 bpm is preferable over 8 bpm because both experimentally and statistically validated.

  6. Flexible End2End Workflow Automation of Hit-Discovery Research.

    PubMed

    Holzmüller-Laue, Silke; Göde, Bernd; Thurow, Kerstin

    2014-08-01

    The article considers a new approach of more complex laboratory automation at the workflow layer. The authors purpose the automation of end2end workflows. The combination of all relevant subprocesses-whether automated or manually performed, independently, and in which organizational unit-results in end2end processes that include all result dependencies. The end2end approach focuses on not only the classical experiments in synthesis or screening, but also on auxiliary processes such as the production and storage of chemicals, cell culturing, and maintenance as well as preparatory activities and analyses of experiments. Furthermore, the connection of control flow and data flow in the same process model leads to reducing of effort of the data transfer between the involved systems, including the necessary data transformations. This end2end laboratory automation can be realized effectively with the modern methods of business process management (BPM). This approach is based on a new standardization of the process-modeling notation Business Process Model and Notation 2.0. In drug discovery, several scientific disciplines act together with manifold modern methods, technologies, and a wide range of automated instruments for the discovery and design of target-based drugs. The article discusses the novel BPM-based automation concept with an implemented example of a high-throughput screening of previously synthesized compound libraries. © 2014 Society for Laboratory Automation and Screening.

  7. Analog signal pre-processing for the Fermilab Main Injector BPM upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, A.L.; Rapisarda, S.M.; Wendt, M.

    2006-05-01

    An analog signal pre-processing scheme was developed, in the framework of the Fermilab Main Injector Beam Position Monitor (BPM) Upgrade, to interface BPM pickup signals to the new digital receiver based read-out system. A key component is the 8-channel electronics module, which uses separate frequency selective gain stages to acquire 53 MHz bunched proton, and 2.5 MHz anti-proton signals. Related hardware includes a filter and combiner box to sum pickup electrode signals in the tunnel. A controller module allows local/remote control of gain settings and activation of gain stages, and supplies test signals. Theory of operation, system overview, and somemore » design details are presented, as well as first beam measurements of the prototype hardware.« less

  8. Some Solved Problems with the SLAC PEP-II B-Factory Beam-Position Monitor System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Ronald G.

    2000-05-05

    The Beam-Position Monitor (BPM) system for the SLAC PEP-II B-Factory has been in operation for over two years. Although the BPM system has met all of its specifications, several problems with the system have been identified and solved. The problems include errors and limitations in both the hardware and software. Solutions of such problems have led to improved performance and reliability. In this paper the authors report on this experience. The process of identifying problems is not at an end and they expect continued improvement of the BPM system.

  9. Results from the RF BPM Upgrade Prototype at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, Anthony; Lill, Robert; Norum, Eric

    2006-11-20

    The Advanced Photon Source (APS), a third-generation synchrotron light source, has been in operation for 10 years. The monopulse radio frequency (RF) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field programmable gate array (FPGA) that performs the signal processing. A prototype systemmore » was constructed and is currently being evaluated. This paper presents the results obtained from laboratory and field tests of the prototype system.« less

  10. Results from the RF BPM upgrade prototype at the Advanced Photon Source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, A.; Lill, R.; Norum, E.

    2006-01-01

    The Advanced Photon Source (APS), a third-generation synchrotron light source, has been in operation for 10 years. The monopulse radio frequency (RF) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field programmable gate array (FPGA) that performs the signal processing. A prototype systemmore » was constructed and is currently being evaluated. This paper presents the results obtained from laboratory and field tests of the prototype system.« less

  11. 500 MHz narrowband beam position monitor electronics for electron synchrotrons

    NASA Astrophysics Data System (ADS)

    Mohos, I.; Dietrich, J.

    1998-12-01

    Narrowband beam position monitor electronics were developed in the Forschungszentrum Jülich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network.

  12. Effect of TE Mode Power on the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Cho-K

    2011-08-26

    The beam chamber of the PEP-II B-Factory Low Energy Ring (LER) arc sections is connected to an antechamber for the absorption of synchrotron radiation on discrete photon stops. The presence of the antechamber substantially reduces the cutoff frequency of the vacuum chamber and, in particular, allows the propagation of higher-order-mode (HOM) TE power generated by beamline components at the BPM signal processing frequency. Calculations of the transmission properties of the TE mode in different sections of the vacuum chamber show that the power is trapped between widely separated bellows in the arc sections. Because of the narrow signal bandwidth andmore » weak coupling of the TE mode to the BPM buttons, the noise contributed by the HOM TE power will not produce a noticeable effect on the BPM position signal voltage. The LER arc vacuum chamber employs an antechamber with a discrete photon stop for absorption of synchrotron radiation and with pumps for maintaining pressure below 10 nTorr [1]. The horizontal dimensions of the antechambers at the pumping chamber section and the magnet chamber section are larger or comparable to that of the beam chamber. Because of the increase in the horizontal dimension, the cutoff frequency of the TE10-like mode (in rectangular coordinates) of the vacuum chamber is considerably reduced and, in particular, is less than the BPM signal processing frequency at 952 MHz. TE power propagating in the vacuum chamber will penetrate through the BPM buttons and will affect the pickup signal if its magnitude is not properly controlled. It is the purpose of this note to clarify various issues pertaining to this problem. TE power is generated when the beam passes a noncylindrically symmetric beamline component such as the RF cavity, the injection region, the IR crotch and the IP region. The beampipes connected to these components have TE cutoff frequencies greater than 952 MHz (for example, the TE cutoff frequency of the RF cavity beampipe is 1.8 GHz), and hence no TE power at this frequency propagates from the component. TE power can also be generated by the scattering of TM power through these beamline components. Since the cutoff frequency of the TM mode is in general higher than that of the TE mode, this mechanism is not pertinent to the problem related to the BPM signal. Consequently, the TE power that needs to be considered is mainly generated by components of the LER arc vacuum chamber, where the TE cutoff frequency is less than the BPM processing frequency.« less

  13. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    NASA Astrophysics Data System (ADS)

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A.; won Jang, Si; Vinokurov, Nikolay A.; Jeong, Young UK; Hee Park, Seong; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  14. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser.

    PubMed

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A; Jang, Si won; Vinokurov, Nikolay A; Jeong, Young U K; Park, Seong Hee; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  15. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noh, Seon Yeong; Kim, Eun-San, E-mail: eskim1@knu.ac.kr; Hwang, Ji-Gwang

    2015-01-15

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using anmore » oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.« less

  16. Physiological strain in the Hungarian mining industry: The impact of physical and psychological factors.

    PubMed

    Varga, József; Nagy, Imre; Szirtes, László; Pórszász, János

    2016-01-01

    The objectives of these investigations completed on workplaces in the Hungarian mining industry were to characterize the physiological strain of workers by means of work pulse and to examine the effects of work-related psychological factors. Continuous heart rate (HR) recording was completed on 71 miners over a total of 794 shifts between 1987 and 1992 in mining plants of the Hungarian mining industry using a 6-channel recorder - Bioport (ZAK, Germany). The work processes were simultaneously documented by video recording along with drawing up the traditional ergonomic workday schedule. All workers passed health evaluation for fitness for work. The effects of different psychological factors (simulated danger, "instrument stress," presence of managers, and effect of prior involvement in accidents as well as different mining technologies and work place illumination) on the work pulse were evaluated. The statistical analysis was completed using SPSS software (version 13.0, SPSS Inc., USA). The work-related physiological strain differed between work places with different mining technologies in groups of 12-18 workers. The work pulse was lowest in bauxite mining (ΔHR = 22±8.9 bpm) and highest in drift drilling in dead rock with electric drilling machine (ΔHR = 30±6.9 bpm). During sham alarm situation the work pulse was significantly higher than during normal activities with the same physical task (ΔHR = 36.7±4.8 bpm vs. 25.8±1.6 bpm, p < 0.001). When work was performed under different psychological stress, the work pulse was consistently higher, while improving the work place illumination decreased the physiological strain appreciably (ΔHR (median, 25-75 percentiles) = 23, 20-26 bmp vs. 28, 25-31.3 bpm, p < 0.001). Recording the heart rate during whole-shift work along with the work conditions gives reliable results and helps isolating factors that contribute to increased strain. The results can be used to implement preventive and health promotion measures. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. Status of the RF BPM upgrade at the Advanced Photon Source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, A.; Bui, H.; Decker, G.

    2008-01-01

    The Advanced Photon Source (APS),a third-generation synchrotron light source, has been in operation for eleven years. The monopulse radio frequency (rf) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field-programmable gate array (FPGA) that performs the signal processing. A first-article system has beenmore » constructed and is currently being evaluated. This paper presents the results of testing of the first-article system as well as the progress made in other areas of this upgrade effort.« less

  18. [Impact of admission heart rate on short-term outcome of ST-elevation myocardial infarction patients].

    PubMed

    Zhang, Han; Yang, Yan-min; Zhu, Jun; Tan, Hui-qiong; Liu, Li-sheng

    2012-01-01

    To evaluate the impact of admission heart rate (HR) on 30-day all-cause death and cardiovascular events in Chinese patients with ST-elevation acute myocardial infarction (STEMI). A total of 7485 Chinese STEMI patients from a global randomized controlled trial (CREATE) database were divided into six groups by admission HR: < 60, 60 - 69, 70 - 79, 80 - 89, 90 - 99 and ≥ 100 bpm. The primary outcome was 30-day all-cause death; the secondary outcomes were the composite of 30-day all-cause death, reinfarction, cardiogenic shock or deadly arrhythmia. Admission glucose level, proportion of female gender, incidence of anterior myocardial infarction, previous diabetes mellitus, hypertension and Killip level II-IV were significantly higher in patients with admission HR ≥ 90 bpm compared to 60 - 69 bpm group (P < 0.05). The 30-day mortality was lowest (6.3%) in the 60 - 69 bpm group and was 9.6% in HR < 60 bpm group (P < 0.05 vs. 60 - 69 bpm group). In patients with admission HR > 60 bpm, the 30-day mortality increased in proportion to higher admission HR: 8.1% in 70 - 79 bpm, 9.2% in 80 - 89 bpm, 12.6% in 90 - 99 bpm and 24.6% in ≥ 100 bpm groups (all P < 0.05 vs. 60 - 69 bpm group). The incidence of MACE was similar as that of 30-day mortality: 27.0% in < 60 bpm, 12.5% in 60 - 69 bpm, 13.7% in 70 - 79 bpm, 14.3% in 80 - 89 bpm, 17.5% in 90 - 99 bpm and 31.1% in ≥ 100 bpm groups. Multivariate analysis showed that the incidence of 30-day mortality positively correlated with the admission HR (P < 0.05) except in the patients with admission HR < 60 bpm (OR = 0.832, P = 0.299), the risk of joint endpoint events was higher in the patients with HR < 60 bpm (OR = 1.532, 95%CI: 1.201 - 1.954, P < 0.05), 90 - 99 bpm (OR = 1.436, 95%CI: 1.091 - 1.889, P < 0.05) or ≥ 100 bpm (OR = 1.893, 95%CI: 1.471 - 2.436, P < 0.001). Admission HR is an independent risk factor for short-term outcome in Chinese STEMI patients.

  19. Correlation of arterial fetal base deficit and lactate changes with severity of variable heart rate decelerations in the near-term ovine fetus.

    PubMed

    Ross, Michael G; Jessie, Marquis; Amaya, Kevin; Matushewski, Brad; Durosier, L Daniel; Frasch, Martin G; Richardson, Bryan S

    2013-04-01

    Recent guidelines classify variable decelerations without detail as to degree of depth. We hypothesized that variable deceleration severity is highly correlated with fetal base deficit accumulation. Seven near-term fetal sheep underwent a series of graded umbilical cord occlusions resulting in mild (30 bpm decrease), moderate (60 bpm decrease), or severe (decrease of 90 bpm to baseline <70 bpm) variable decelerations at 2.5 minute intervals. Mild, moderate, and severe variable decelerations increased fetal base deficit (0.21 ± 0.03, 0.27 ± 0.03, and 0.54 ± 0.09 mEq/L per minute) in direct proportion to severity. During recovery, fetal base deficit cleared at 0.12 mEq/L per minute. In this model, ovine fetuses can tolerate repetitive mild and moderate variable decelerations with minimal change in base deficit and lactate. In contrast, repetitive severe variable decelerations may result in significant base deficit increases, dependent on frequency. Modified guideline differentiation of mild/moderate vs severe variable decelerations may aid in the interpretation of fetal heart rate tracings and optimization of clinical management paradigms. Copyright © 2013 Mosby, Inc. All rights reserved.

  20. CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW)

    NASA Technical Reports Server (NTRS)

    Yamamoto, Clifford K.; Orozco, David S.; Byrne, D. J.; Allen, Steven J.; Sahasrabudhe, Adit; Lang, Minh

    2012-01-01

    This software provides essential startup and initialization routines for the CoNNeCT baseband processor module (BPM) hardware upon power-up. A command and data handling (C&DH) interface is provided via 1553 and diagnostic serial interfaces to invoke operational, reconfiguration, and test commands within the code. The BCSW has features unique to the hardware it is responsible for managing. In this case, the CoNNeCT BPM is configured with an updated CPU (Atmel AT697 SPARC processor) and a unique set of memory and I/O peripherals that require customized software to operate. These features include configuration of new AT697 registers, interfacing to a new HouseKeeper with a flash controller interface, a new dual Xilinx configuration/scrub interface, and an updated 1553 remote terminal (RT) core. The BCSW is intended to provide a "safe" mode for the BPM when initially powered on or when an unexpected trap occurs, causing the processor to reset. The BCSW allows the 1553 bus controller in the spacecraft or payload controller to operate the BPM over 1553 to upload code; upload Xilinx bit files; perform rudimentary tests; read, write, and copy the non-volatile flash memory; and configure the Xilinx interface. Commands also exist over 1553 to cause the CPU to jump or call a specified address to begin execution of user-supplied code. This may be in the form of a real-time operating system, test routine, or specific application code to run on the BPM.

  1. Development of BPM Electronics at the JLAB FEL

    NASA Astrophysics Data System (ADS)

    Sexton, D.; Evtushenko, P.; Jordan, K.; Yan, J.; Dutton, S.; Moore, W.; Evans, R.; Coleman, J.

    2006-11-01

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with a 74.85 MHz micropulse frequency. For diagnostic reasons and for machine tune up, the micropulse frequency can be reduced to 1.17 MHz, which corresponds to about 160 μA of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 μm is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.

  2. Development of BPM Electronics at the JLAB FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, D.; Evtushenko, P.; Jordan, K.

    2006-11-20

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with a 74.85 MHz micropulse frequency. For diagnostic reasons and for machine tune up, the micropulse frequency can be reducedmore » to 1.17 MHz, which corresponds to about 160 {mu}A of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 {mu}m is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.« less

  3. Development of BPM Electronics at the JLAB FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel Sexton; Pavel Evtushenko; Kevin Jordan

    2006-05-01

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with the micropulse up to 74.85 MHz. For diagnostic reasons and for the machine tune up, the micropulse frequency canmore » be reduced to 1.17 MHz, which corresponds to about 160 ?A of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 ?m is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.« less

  4. Innovative practice model to optimize resource utilization and improve access to care for high-risk and BRCA+ patients.

    PubMed

    Head, Linden; Nessim, Carolyn; Usher Boyd, Kirsty

    2017-02-01

    Bilateral prophylactic mastectomy (BPM) has demonstrated breast cancer risk reduction in high-risk/ BRCA + patients. However, priority of active cancers coupled with inefficient use of operating room (OR) resources presents challenges in offering BPM in a timely manner. To address these challenges, a rapid access prophylactic mastectomy and immediate reconstruction (RAPMIR) program was innovated. The purpose of this study was to evaluate RAPMIR with regards to access to care and efficiency. We retrospectively reviewed the cases of all high-risk/ BRCA + patients having had BPM between September 2012 and August 2014. Patients were divided into 2 groups: those managed through the traditional model and those managed through the RAPMIR model. RAPMIR leverages 2 concurrently running ORs with surgical oncology and plastic surgery moving between rooms to complete 3 combined BPMs with immediate reconstruction in addition to 1-2 independent cases each operative day. RAPMIR eligibility criteria included high-risk/ BRCA + status; BPM with immediate, implant-based reconstruction; and day surgery candidacy. Wait times, case volumes and patient throughput were measured and compared. There were 16 traditional patients and 13 RAPMIR patients. Mean wait time (days from referral to surgery) for RAPMIR was significantly shorter than for the traditional model (165.4 v. 309.2 d, p = 0.027). Daily patient throughput (4.3 v. 2.8), plastic surgery case volume (3.7 v. 1.6) and surgical oncology case volume (3.0 v. 2.2) were significantly greater in the RAPMIR model than the traditional model ( p = 0.003, p < 0.001 and p = 0.015, respectively). A multidisciplinary model with optimized scheduling has the potential to improve access to care and optimize resource utilization.

  5. Innovative practice model to optimize resource utilization and improve access to care for high-risk and BRCA+ patients

    PubMed Central

    Head, Linden; Nessim, Carolyn; Boyd, Kirsty Usher

    2017-01-01

    Background Bilateral prophylactic mastectomy (BPM) has shown breast cancer risk reduction in high-risk/BRCA+ patients. However, priority of active cancers coupled with inefficient use of operating room (OR) resources presents challenges in offering BPM in a timely manner. To address these challenges, a rapid access prophylactic mastectomy and immediate reconstruction (RAPMIR) program was innovated. The purpose of this study was to evaluate RAPMIR with regards to access to care and efficiency. Methods We retrospectively reviewed the cases of all high-risk/BRCA+ patients having had BPM between September 2012 and August 2014. Patients were divided into 2 groups: those managed through the traditional model and those managed through the RAPMIR model. RAPMIR leverages 2 concurrently running ORs with surgical oncology and plastic surgery moving between rooms to complete 3 combined BPMs with immediate reconstruction in addition to 1–2 independent cases each operative day. RAPMIR eligibility criteria included high-risk/BRCA+ status; BPM with immediate, implant-based reconstruction; and day surgery candidacy. Wait times, case volumes and patient throughput were measured and compared. Results There were 16 traditional patients and 13 RAPMIR patients. Mean wait time (days from referral to surgery) for RAPMIR was significantly shorter than for the traditional model (165.4 v. 309.2 d, p = 0.027). Daily patient throughput (4.3 v. 2.8), plastic surgery case volume (3.7 v. 1.6) and surgical oncology case volume (3.0 v. 2.2) were significantly greater in the RAPMIR model than the traditional model (p = 0.003, p < 0.001 and p = 0.015, respectively). Conclusion A multidisciplinary model with optimized scheduling has the potential to improve access to care and optimize resource utilization. PMID:28234588

  6. Innovative practice model to optimize resource utilization and improve access to care for high-risk and BRCA+ patients.

    PubMed

    Head, Linden; Nessim, Carolyn; Usher Boyd, Kirsty

    2016-12-01

    Bilateral prophylactic mastectomy (BPM) has demonstrated breast cancer risk reduction in high-risk/ BRCA + patients. However, priority of active cancers coupled with inefficient use of operating room (OR) resources presents challenges in offering BPM in a timely manner. To address these challenges, a rapid access prophylactic mastectomy and immediate reconstruction (RAPMIR) program was innovated. The purpose of this study was to evaluate RAPMIR with regards to access to care and efficiency. We retrospectively reviewed the cases of all high-risk/ BRCA + patients having had BPM between September 2012 and August 2014. Patients were divided into 2 groups: those managed through the traditional model and those managed through the RAPMIR model. RAPMIR leverages 2 concurrently running ORs with surgical oncology and plastic surgery moving between rooms to complete 3 combined BPMs with immediate reconstruction in addition to 1-2 independent cases each operative day. RAPMIR eligibility criteria included high-risk/ BRCA + status; BPM with immediate, implant-based reconstruction; and day surgery candidacy. Wait times, case volumes and patient throughput were measured and compared. There were 16 traditional patients and 13 RAPMIR patients. Mean wait time (days from referral to surgery) for RAPMIR was significantly shorter than for the traditional model (165.4 v. 309.2 d, p = 0.027). Daily patient throughput (4.3 v. 2.8), plastic surgery case volume (3.7 v. 1.6) and surgical oncology case volume (3.0 v. 2.2) were significantly greater in the RAPMIR model than the traditional model ( p = 0.003, p < 0.001 and p = 0.015, respectively). A multidisciplinary model with optimized scheduling has the potential to improve access to care and optimize resource utilization.

  7. Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography.

    PubMed

    Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro

    2018-01-01

    We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.

  8. Heart rate at admission is a predictor of in-hospital mortality in patients with acute coronary syndromes: Results from 58 European hospitals: The European Hospital Benchmarking by Outcomes in acute coronary syndrome Processes study.

    PubMed

    Jensen, Magnus T; Pereira, Marta; Araujo, Carla; Malmivaara, Anti; Ferrieres, Jean; Degano, Irene R; Kirchberger, Inge; Farmakis, Dimitrios; Garel, Pascal; Torre, Marina; Marrugat, Jaume; Azevedo, Ana

    2018-03-01

    The purpose of this study was to investigate the relationship between heart rate at admission and in-hospital mortality in patients with ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation acute coronary syndrome (NSTE-ACS). Consecutive ACS patients admitted in 2008-2010 across 58 hospitals in six participant countries of the European Hospital Benchmarking by Outcomes in ACS Processes (EURHOBOP) project (Finland, France, Germany, Greece, Portugal and Spain). Cardiogenic shock patients were excluded. Associations between heart rate at admission in categories of 10 beats per min (bpm) and in-hospital mortality were estimated by logistic regression in crude models and adjusting for age, sex, obesity, smoking, hypertension, diabetes, known heart failure, renal failure, previous stroke and ischaemic heart disease. In total 10,374 patients were included. In both STEMI and NSTE-ACS patients, a U-shaped relationship between admission heart rate and in-hospital mortality was found. The lowest risk was observed for heart rates between 70-79 bpm in STEMI and 60-69 bpm in NSTE-ACS; risk of mortality progressively increased with lower or higher heart rates. In multivariable models, the relationship persisted but was significant only for heart rates >80 bpm. A similar relationship was present in both patients with or without diabetes, above or below age 75 years, and irrespective of the presence of atrial fibrillation or use of beta-blockers. Heart rate at admission is significantly associated with in-hospital mortality in patients with both STEMI and NSTE-ACS. ACS patients with admission heart rate above 80 bpm are at highest risk of in-hospital mortality.

  9. An ontological knowledge framework for adaptive medical workflow.

    PubMed

    Dang, Jiangbo; Hedayati, Amir; Hampel, Ken; Toklu, Candemir

    2008-10-01

    As emerging technologies, semantic Web and SOA (Service-Oriented Architecture) allow BPMS (Business Process Management System) to automate business processes that can be described as services, which in turn can be used to wrap existing enterprise applications. BPMS provides tools and methodologies to compose Web services that can be executed as business processes and monitored by BPM (Business Process Management) consoles. Ontologies are a formal declarative knowledge representation model. It provides a foundation upon which machine understandable knowledge can be obtained, and as a result, it makes machine intelligence possible. Healthcare systems can adopt these technologies to make them ubiquitous, adaptive, and intelligent, and then serve patients better. This paper presents an ontological knowledge framework that covers healthcare domains that a hospital encompasses-from the medical or administrative tasks, to hospital assets, medical insurances, patient records, drugs, and regulations. Therefore, our ontology makes our vision of personalized healthcare possible by capturing all necessary knowledge for a complex personalized healthcare scenario involving patient care, insurance policies, and drug prescriptions, and compliances. For example, our ontology facilitates a workflow management system to allow users, from physicians to administrative assistants, to manage, even create context-aware new medical workflows and execute them on-the-fly.

  10. Optics measurement and correction for the Relativistic Heavy Ion Collider

    NASA Astrophysics Data System (ADS)

    Shen, Xiaozhe

    The quality of beam optics is of great importance for the performance of a high energy accelerator like the Relativistic Heavy Ion Collider (RHIC). The turn-by-turn (TBT) beam position monitor (BPM) data can be used to derive beam optics. However, the accuracy of the derived beam optics is often limited by the performance and imperfections of instruments as well as measurement methods and conditions. Therefore, a robust and model-independent data analysis method is highly desired to extract noise-free information from TBT BPM data. As a robust signal-processing technique, an independent component analysis (ICA) algorithm called second order blind identification (SOBI) has been proven to be particularly efficient in extracting physical beam signals from TBT BPM data even in the presence of instrument's noise and error. We applied the SOBI ICA algorithm to RHIC during the 2013 polarized proton operation to extract accurate linear optics from TBT BPM data of AC dipole driven coherent beam oscillation. From the same data, a first systematic estimation of RHIC BPM noise performance was also obtained by the SOBI ICA algorithm, and showed a good agreement with the RHIC BPM configurations. Based on the accurate linear optics measurement, a beta-beat response matrix correction method and a scheme of using horizontal closed orbit bumps at sextupoles for arc beta-beat correction were successfully applied to reach a record-low beam optics error at RHIC. This thesis presents principles of the SOBI ICA algorithm and theory as well as experimental results of optics measurement and correction at RHIC.

  11. A preliminary study of a running speed based heart rate prediction during an incremental treadmill exercise.

    PubMed

    Dae-Geun Jang; Byung-Hoon Ko; Sub Sunoo; Sang-Seok Nam; Hun-Young Park; Sang-Kon Bae

    2016-08-01

    This preliminary study investigates feasibility of a running speed based heart rate (HR) prediction. It is basically motivated from the assumption that there is a significant relationship between HR and the running speed. In order to verify the assumption, HR and running speed data from 217 subjects of varying aerobic capabilities were simultaneously collected during an incremental treadmill exercise. A running speed was defined as a treadmill speed and its corresponding heart rate was calculated by averaging the last one minute HR values of each session. The feasibility was investigated by assessing a correlation between the heart rate and the running speed using inter-subject (between-subject) and intra-subject (within-subject) datasets with regression orders of 1, 2, 3, and 4, respectively. Furthermore, HR differences between actual and predicted HRs were also employed to investigate the feasibility of the running speed in predicting heart rate. In the inter-subject analysis, a strong positive correlation and a reasonable HR difference (r = 0.866, 16.55±11.24 bpm @ 1st order; r = 0.871, 15.93±11.49 bpm @ 2nd order; r = 0.897, 13.98±10.80 bpm @ 3rd order; and r = 0.899, 13.93±10.64 bpm @ 4th order) were obtained, and a very high positive correlation and a very low HR difference (r = 0.978, 6.46±3.89 bpm @ 1st order; r = 0.987, 5.14±2.87 bpm @ 2nd order; r = 0.996, 2.61±2.03 bpm @ 3rd order; and r = 0.997, 2.04±1.73 bpm @ 4th order) were obtained in the intra-subject analysis. It can therefore be concluded that 1) heart rate is highly correlated with a running speed; 2) heart rate can be approximately estimated by a running speed with a proper statistical model (e.g., 3rd-order regression); and 3) an individual HR-speed calibration process may improve the prediction accuracy.

  12. ProcessGene-Connect: SOA Integration between Business Process Models and Enactment Transactions of Enterprise Software Systems

    NASA Astrophysics Data System (ADS)

    Wasser, Avi; Lincoln, Maya

    In recent years, both practitioners and applied researchers have become increasingly interested in methods for integrating business process models and enterprise software systems through the deployment of enabling middleware. Integrative BPM research has been mainly focusing on the conversion of workflow notations into enacted application procedures, and less effort has been invested in enhancing the connectivity between design level, non-workflow business process models and related enactment systems such as: ERP, SCM and CRM. This type of integration is useful at several stages of an IT system lifecycle, from design and implementation through change management, upgrades and rollout. The paper presents an integration method that utilizes SOA for connecting business process models with corresponding enterprise software systems. The method is then demonstrated through an Oracle E-Business Suite procurement process and its ERP transactions.

  13. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction.

    PubMed

    Messias, Leandro Rocha; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas; Azevedo, Jader Cunha de; Messias, Ana Carolina Nader Vasconcelos; Maróstica, Elisabeth; Mesquita, Claudio Tinoco

    2016-05-01

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO2). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO2 and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity.

  14. Bipyrimidine ruthenium(II) arene complexes: structure, reactivity and cytotoxicity.

    PubMed

    Betanzos-Lara, Soledad; Novakova, Olga; Deeth, Robert J; Pizarro, Ana M; Clarkson, Guy J; Liskova, Barbora; Brabec, Viktor; Sadler, Peter J; Habtemariam, Abraha

    2012-10-01

    The synthesis and characterization of complexes [(η(6)-arene)Ru(N,N')X][PF(6)], where arene is para-cymene (p-cym), biphenyl (bip), ethyl benzoate (etb), hexamethylbenzene (hmb), indane (ind) or 1,2,3,4-tetrahydronaphthalene (thn), N,N' is 2,2'-bipyrimidine (bpm) and X is Cl, Br or I, are reported, including the X-ray crystal structures of [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)I][PF(6)] and [(η(6)-etb)Ru(bpm)Cl][PF(6)]. Complexes in which N,N' is 1,10-phenanthroline (phen), 1,10-phenanthroline-5,6-dione or 4,7-diphenyl-1,10-phenanthroline (bathophen) were studied for comparison. The Ru(II) arene complexes undergo ligand-exchange reactions in aqueous solution at 310 K; their half-lives for hydrolysis range from 14 to 715 min. Density functional theory calculations on [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-p-cym)Ru(bpm)Br][PF(6)], [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)Br][PF(6)] and [(η(6)-bip)Ru(bpm)I][PF(6)] suggest that aquation occurs via an associative pathway and that the reaction is thermodynamically favourable when the leaving ligand is I > Br ≈ Cl. pK (a)* values for the aqua adducts of the complexes range from 6.9 to 7.32. A binding preference for 9-ethylguanine (9-EtG) compared with 9-ethyladenine (9-EtA) was observed for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-hmb)Ru(bpm)Cl](+), [(η(6)-ind)Ru(bpm)Cl](+), [(η(6)-thn)Ru(bpm)Cl](+), [(η(6)-p-cym)Ru(phen)Cl](+) and [(η(6)-p-cym)Ru(bathophen)Cl](+) in aqueous solution at 310 K. The X-ray crystal structure of the guanine complex [(η(6)-p-cym)Ru(bpm)(9-EtG-N7)][PF(6)](2) shows multiple hydrogen bonding. Density functional theory calculations show that the 9-EtG adducts of all complexes are thermodynamically preferred compared with those of 9-EtA. However, the bmp complexes are inactive towards A2780 human ovarian cancer cells. Calf thymus DNA interactions for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)] and [(η(6)-p-cym)Ru(phen)Cl][PF(6)] consist of weak coordinative, intercalative and monofunctional coordination. Binding to biomolecules such as glutathione may play a role in deactivating the bpm complexes.

  15. Discovering Collaboration and Knowledge Management Practices for the Future Digital Factory

    NASA Astrophysics Data System (ADS)

    Flores, Myrna; Vera, Tomas; Tucci, Christopher

    Recently there has been an explosion of new technologies and tools such as wikis, blogs, tags, Facebook, among many others, that are commonly identified under Web 2.0 and which promise a new digital business ecosystem fed by formal/informal and internal/external relationships and interactions. Although Web 2.0 is very promising to enable such collective knowledge creation, technology by itself is not the only ingredient. It is also required to define the right strategy, governance, culture, processes, training, incentives among others, before implementing such innovative open spaces for collaboration and knowledge sharing. Therefore, the objective of this paper is to present a Knowledge Management (KM) Framework and a Maturity Model developed by a CEMEX and EPFL collaborative research project to discover the AS-IS collaboration practices in CEMEX before the implementation of the SMARTBRICKS Web 2.0 prototype for Business Process Management (BPM), currently under development by the Intelligent Manufacturing Systems (IMS) Swiss Digital Factory (DiFac) project.

  16. Resting Bradycardia, Enhanced Postexercise Heart Rate Recovery and Cardiorespiratory Fitness in Recreational Ballroom Dancers.

    PubMed

    Cruz, Carlos Janssen Gomes da; Molina, Guilherme Eckhardt; Porto, Luiz Guilherme Grossi; Junqueira, Luiz Fernando

    2017-09-01

    In a cross-sectional study design, we evaluated the resting heart rate (HR baseline ) and exercise and postexercise stress test-related chronotropic responses in male practitioners of recreational ballroom dancing (BD; n = 25, M age = 26.6 ± 6.1 years) compared to a control group of insufficiently active nondancers (CG; n = 25, M age = 25.9 ± 4.5 years). All participants underwent a submaximal exercise test. At 85% of the maximal predicted HR, the recovery protocol was started, and heart rate recovery (HRR) was recorded during 1-min intervals for 5 min. Compared with CG, BD showed lower HR baseline (70 beats per minute [bpm] vs. 62 bpm, respectively, U = 143, p < .05, ES = .46), lower preexercise HR (94 bpm vs. 86 bpm, U = 157, p < .05, ES = .42), longer exercise test duration (346 s vs. 420 s, U = 95.5, p < .05, ES = .59), and higher HRR for 5 min postexercise (U = 1.29-1.89, p < .05, ES = .33-.50) as follows: 1st min (32 bpm vs. 40 bpm), 2nd min (45 bpm vs. 53 bpm), 3rd min (51 bpm vs. 58 bpm), 4th min (55 bpm vs. 59 bpm), and 5th min (59 bpm vs. 63 bpm). The coefficient of HRR from the 1st min to the 5th min postexercise was similar in both groups (U = 229-311, p > .05, ES = < .10-.22). Heightened cardiovascular functional status characterized by favorable enhanced chronotropic dynamics appears to occur in practitioners of recreational ballroom dancing, which suggests that this modality of exercise may result in health benefits.

  17. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    PubMed

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (p<0.05) than forearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (p<0.05) than those found for forearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  18. Upgrade of BPM Electronics for the SPring-8 Storage Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, Shigeki; Fujita, Takahiro; Shoji, Masazumi

    2006-11-20

    SPring-8, a 3rd generation synchrotron light source, has operated since 1997. Improvement of BPM performance is required as a part of upgrading activities of the storage ring as a light source. We have developed new electronics circuits for signal processing of the storage ring BPM, with target performance of sub-{mu}m range resolution with sufficiently fast measurement speed and good long-term stability. A set of the new circuits consists of multiplexers, an RF amplifier, a mixer, an IF amplifier, and a local oscillator for analog signal processing. The IF amplifier outputs are sampled with 16-bit 2-MSPS ADC on ADC boards andmore » the data are sent to a DSP board. The sampled data are processed and converted to position information in the DSP. A multiplexing method was employed to have a better stability of the performance by cancellation of variation common to each channel. Evaluation of the performance by using a prototype shows that position resolution well into the sub-{mu}m range has been achieved with a bandwidth of 1 kHz, and long-term stability of within 1 {mu}m has also been achieved.« less

  19. Measurement and Compensation of BPM Chamber Motion in HLS

    NASA Astrophysics Data System (ADS)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-06-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  20. Empowerment of Patients with Hypertension through BPM, IoT and Remote Sensing.

    PubMed

    Ruiz-Fernández, Daniel; Marcos-Jorquera, Diego; Gilart-Iglesias, Virgilio; Vives-Boix, Víctor; Ramírez-Navarro, Javier

    2017-10-04

    Hypertension affects one in five adults worldwide. Healthcare processes require interdisciplinary cooperation and coordination between medical teams, clinical processes, and patients. The lack of patients' empowerment and adherence to treatment makes necessary to integrate patients, data collecting devices and clinical processes. For this reason, in this paper we propose a model based on Business Process Management paradigm, together with a group of technologies, techniques and IT principles which increase the benefits of the paradigm. To achieve the proposed model, the clinical process of the hypertension is analyzed with the objective of detecting weaknesses and improving the process. Once the process is analyzed, an architecture that joins health devices and environmental sensors, together with an information system, has been developed. To test the architecture, a web system connected with health monitors and environment sensors, and with a mobile app have been implemented.

  1. Empowerment of Patients with Hypertension through BPM, IoT and Remote Sensing

    PubMed Central

    Ramírez-Navarro, Javier

    2017-01-01

    Hypertension affects one in five adults worldwide. Healthcare processes require interdisciplinary cooperation and coordination between medical teams, clinical processes, and patients. The lack of patients’ empowerment and adherence to treatment makes necessary to integrate patients, data collecting devices and clinical processes. For this reason, in this paper we propose a model based on Business Process Management paradigm, together with a group of technologies, techniques and IT principles which increase the benefits of the paradigm. To achieve the proposed model, the clinical process of the hypertension is analyzed with the objective of detecting weaknesses and improving the process. Once the process is analyzed, an architecture that joins health devices and environmental sensors, together with an information system, has been developed. To test the architecture, a web system connected with health monitors and environment sensors, and with a mobile app have been implemented. PMID:28976940

  2. Photobiomodulation therapy in the management of oral mucositis: search for the optimal clinical treatment parameters.

    PubMed

    Elad, Sharon; Arany, Praveen; Bensadoun, Rene-Jean; Epstein, Joel B; Barasch, Andrei; Raber-Durlacher, Judith

    2018-05-22

    This commentary attempts to clarify the setting of photobiomodulation (BPM) therapy in the management of oral mucositis. The suggested dose range balances efficacy data with our current understanding about PBM safety. The literature about the molecular basis of photobiomodulation and its controversial relationship to malignant transformation is briefly presented.

  3. Measurement and Compensation of BPM Chamber Motion in HLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J. W.; Sun, B. G.; Cao, Y.

    2010-06-23

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS.more » The horizontal drifts of beam orbit have been really suppressed within 20{mu}m without the compensation of BPM chamber motion in the runtime.« less

  4. Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics

    PubMed Central

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2012-01-01

    Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296

  5. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    PubMed

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  6. Hedgehog activity controls opening of the primary mouth

    PubMed Central

    Tabler, Jacqueline M.; Bolger, Trióna G.; Wallingford, John; Liu, Karen J.

    2014-01-01

    To feed or breathe, the oral opening must connect with the gut. The foregut and oral tissues converge at the primary mouth, forming the buccopharyngeal membrane (BPM), a bilayer epithelium. Failure to form the opening between gut and mouth has significant ramifications, and many craniofacial disorders have been associated with defects in this process. Oral perforation is characterized by dissolution of the BPM, but little is known about this process. In humans, failure to form a continuous mouth opening is associated with mutations in Hedgehog (Hh) pathway members; however, the role of Hh in primary mouth development is untested. Here, we show, using Xenopus, that Hh signaling is necessary and sufficient to initiate mouth formation, and that Hh activation is required in a dose-dependent fashion to determine the size of the mouth. This activity lies upstream of the previously demonstrated role for Wnt signal inhibition in oral perforation. We then turn to mouse mutants to establish that SHH and Gli3 are indeed necessary for mammalian mouth development. Our data suggest that Hh-mediated BPM persistence may underlie oral defects in human craniofacial syndromes. PMID:25300580

  7. Imprint lithography template technology for bit patterned media (BPM)

    NASA Astrophysics Data System (ADS)

    Lille, J.; Patel, K.; Ruiz, R.; Wu, T.-W.; Gao, H.; Wan, Lei; Zeltzer, G.; Dobisz, E.; Albrecht, T. R.

    2011-11-01

    Bit patterned media (BPM) for magnetic recording has emerged as a promising technology to deliver thermally stable magnetic storage at densities beyond 1Tb/in2. Insertion of BPM into hard disk drives will require the introduction of nanoimprint lithography and other nanofabrication processes for the first time. In this work, we focus on nanoimprint and nanofabrication challenges that are being overcome in order to produce patterned media. Patterned media has created the need for new tools and processes, such as an advanced rotary e-beam lithography tool and block copolymer integration. The integration of block copolymer is through the use of a chemical contrast pattern on the substrate which guides the alignment of di-block copolymers. Most of the work on directed self assembly for patterned media applications has, until recently, concentrated on the formation of circular dot patterns in a hexagonal close packed lattice. However, interactions between the read head and media favor a bit aspect ratio (BAR) greater than one. This design constraint has motivated new approaches for using self-assembly to create suitable high-BAR master patterns and has implications for template fabrication.

  8. Heart rate at baseline influences the effect of ivabradine on cardiovascular outcomes in chronic heart failure: analysis from the SHIFT study.

    PubMed

    Böhm, Michael; Borer, Jeffrey; Ford, Ian; Gonzalez-Juanatey, Jose R; Komajda, Michel; Lopez-Sendon, Jose; Reil, Jan-Christian; Swedberg, Karl; Tavazzi, Luigi

    2013-01-01

    We analysed the effect of ivabradine on outcomes in heart failure (HF) patients on recommended background therapies with heart rates ≥75 bpm and <75 bpm in the SHIFT trial. A cut-off value of ≥75 bpm was chosen by the EMEA for approval for the use of ivabradine in chronic heart failure. The SHIFT population was divided by baseline heart rate ≥75 or <75 bpm. The effect of ivabradine was analysed for primary composite endpoint (cardiovascular death or HF hospitalization) and other endpoints. In the ≥75 bpm group, ivabradine reduced primary endpoint (HR 0.76, 95 % CI 0.68-0.85, P < 0.0001), all-cause mortality (HR 0.83, 95 % CI, 0.72-0.96, P = 0.0109), cardiovascular mortality (HR 0.83, 95 % CI, (0.71-0.97, P = 0.0166), HF death (HR 0.61, 95 % CI, 0.46-0.81, P < 0.0006), and HF hospitalization (HR 0.70, 95 % CI, 0.61-0.80, P < 0.0001). Risk reduction depended on heart rate after 28 days, with the best protection for heart rates <60 bpm or reductions >10 bpm. None of the endpoints was significantly reduced in the <75 bpm group, though there were trends for risk reductions in HF death and hospitalization for heart rate <60 bpm and reductions >10 bpm. Ivabradine was tolerated similarly in both groups. The effect of ivabradine on outcomes is greater in patients with heart rate ≥75 bpm with heart rates achieved <60 bpm or heart rate reductions >10 bpm predicting best risk reduction. Our findings emphasize the importance of identification of high-risk HF patients by high heart rates and their treatment with heart rate-lowering drugs such as ivabradine.

  9. Quality of life among patients after bilateral prophylactic mastectomy: a systematic review of patient-reported outcomes.

    PubMed

    Razdan, Shantanu N; Patel, Vishal; Jewell, Sarah; McCarthy, Colleen M

    2016-06-01

    Bilateral prophylactic mastectomy (BPM) is effective in reducing the risk of breast cancer in women with a well-defined family history of breast cancer or in women with BRCA 1 or 2 mutations. Evaluating patient-reported outcomes following BPM are thus essential for evaluating success of BPM from patient's perspective. Our systematic review aimed to: (1) identify studies describing health-related quality of life (HRQOL) in patients following BPM with or without reconstruction; (2) assess the effect of BPM with or without reconstruction on HRQOL; and (3) identify predictors of HRQOL post-BPM. We performed a systematic review of literature using the PRISMA guidelines. PubMed, Embase, PsycINFO, Web of Science, Scopus and Cochrane databases were searched. The initial search resulted in 1082 studies; 22 of these studies fulfilled our inclusion criteria. Post-BPM, patients are satisfied with the outcomes and report high psychosocial well-being and positive body image. Sexual well-being and somatosensory function are most negatively affected. Vulnerability, psychological distress and preoperative cancer distress are significant negative predictors of quality of life and body image post-BPM. There is a paucity of high-quality data on outcomes of different HRQOL domains post-BPM. Future studies should strive to use validated and breast-specific PRO instruments for measuring HRQOL. This will facilitate shared decision-making by enabling surgeons to provide evidence-based answers to women contemplating BPM.

  10. Design and cold test of S-BAND cavity BPM for HLS

    NASA Astrophysics Data System (ADS)

    Luo, Qing; Sun, BaoGen; Jia, QiKa; He, DuoHui; Fang, Jia

    2011-12-01

    An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.

  11. The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jankowiak, A.; Wille, K.; /Dortmund U. /SLAC

    2011-08-25

    For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn outmore » to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.« less

  12. Infrared vibrational spectroscopy of [Ru(bpy)2(bpm)]2+ and [Ru(bpy)3]2+ in the excited triplet state.

    PubMed

    Mukuta, Tatsuhiko; Fukazawa, Naoto; Murata, Kei; Inagaki, Akiko; Akita, Munetaka; Tanaka, Sei'ichi; Koshihara, Shin-ya; Onda, Ken

    2014-03-03

    This work involved a detailed investigation into the infrared vibrational spectra of ruthenium polypyridyl complexes, specifically heteroleptic [Ru(bpy)2(bpm)](2+) (bpy = 2,2'-bipyridine and bpm = 2,2'-bipyrimidine) and homoleptic [Ru(bpy)3](2+), in the excited triplet state. Transient spectra were acquired 500 ps after photoexcitation, corresponding to the vibrational ground state of the excited triplet state, using time-resolved infrared spectroscopy. We assigned the observed bands to specific ligands in [Ru(bpy)2(bpm)](2+) based on the results of deuterium substitution and identified the corresponding normal vibrational modes using quantum-chemical calculations. Through this process, the more complex vibrational bands of [Ru(bpy)3](2+) were assigned to normal vibrational modes. The results are in good agreement with the model in which excited electrons are localized on a single ligand. We also found that the vibrational bands of both complexes associated with the ligands on which electrons are little localized appear at approximately 1317 and 1608 cm(-1). These assignments should allow the study of the reaction dynamics of various photofunctional systems including ruthenium polypyridyl complexes.

  13. A novel electromagnetic design and a new manufacturing process for the cavity BPM (Beam Position Monitor)

    NASA Astrophysics Data System (ADS)

    Dal Forno, Massimo; Craievich, Paolo; Baruzzo, Roberto; De Monte, Raffaele; Ferianis, Mario; Lamanna, Giuseppe; Vescovo, Roberto

    2012-01-01

    The Cavity Beam Position Monitor (BPM) is a beam diagnostic instrument which, in a seeded Free Electron Laser (FEL), allows the measurement of the electron beam position in a non-destructive way and with sub-micron resolution. It is composed by two resonant cavities called reference and position cavity, respectively. The measurement exploits the dipole mode that arises when the electron bunch passes off axis. In this paper we describe the Cavity BPM that has been designed and realized in the context of the FERMI@Elettra project [1]. New strategies have been adopted for the microwave design, for both the reference and the position cavities. Both cavities have been simulated by means of Ansoft HFSS [2] and CST Particle Studio [3], and have been realized using high precision lathe and wire-EDM (Electro-Discharge) machine, with a new technique that avoids the use of the sinker-EDM machine. Tuners have been used to accurately adjust the working frequencies for both cavities. The RF parameters have been estimated, and the modifications of the resonant frequencies produced by brazing and tuning have been evaluated. Finally, the Cavity BPM has been installed and tested in the presence of the electron beam.

  14. Workflow-Based Software Development Environment

    NASA Technical Reports Server (NTRS)

    Izygon, Michel E.

    2013-01-01

    The Software Developer's Assistant (SDA) helps software teams more efficiently and accurately conduct or execute software processes associated with NASA mission-critical software. SDA is a process enactment platform that guides software teams through project-specific standards, processes, and procedures. Software projects are decomposed into all of their required process steps or tasks, and each task is assigned to project personnel. SDA orchestrates the performance of work required to complete all process tasks in the correct sequence. The software then notifies team members when they may begin work on their assigned tasks and provides the tools, instructions, reference materials, and supportive artifacts that allow users to compliantly perform the work. A combination of technology components captures and enacts any software process use to support the software lifecycle. It creates an adaptive workflow environment that can be modified as needed. SDA achieves software process automation through a Business Process Management (BPM) approach to managing the software lifecycle for mission-critical projects. It contains five main parts: TieFlow (workflow engine), Business Rules (rules to alter process flow), Common Repository (storage for project artifacts, versions, history, schedules, etc.), SOA (interface to allow internal, GFE, or COTS tools integration), and the Web Portal Interface (collaborative web environment

  15. Development of a BPM Lock-In Diagnostic System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard Dickson

    2003-05-12

    A system has been developed for the acquisition and analysis of high rate, time coherent BPM data across the Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF). This system will allow the acquisition of Beam Position Monitor (BPM) position and intensity information at a rate in excess 7 KHz for approximately 200 BPMs in a time synchronous manner. By inducing minute sinusoidal transverse beam motion in the CEBAF injector, with known phase relative to the synchronized BPM acquisition, it is possible to derive several types of useful information. Analysis of the BPM intensity data, which is proportional to beam current,more » by beating the signal with an in-phase sinusoidal representation of the transverse kick can localize beam scraping to a particular BPM. Similarly, real-time optics information may be deduced with an analysis of BPM position data. This paper will detail the frequency lock-in technique applied and present status.« less

  16. Analytical expression for position sensitivity of linear response beam position monitor having inter-electrode cross talk

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Ojha, A.; Garg, A. D.; Puntambekar, T. A.; Senecha, V. K.

    2017-02-01

    According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.

  17. Successive approximation algorithm for beam-position-monitor-based LHC collimator alignment

    NASA Astrophysics Data System (ADS)

    Valentino, Gianluca; Nosych, Andriy A.; Bruce, Roderik; Gasior, Marek; Mirarchi, Daniele; Redaelli, Stefano; Salvachua, Belen; Wollmann, Daniel

    2014-02-01

    Collimators with embedded beam position monitor (BPM) button electrodes will be installed in the Large Hadron Collider (LHC) during the current long shutdown period. For the subsequent operation, BPMs will allow the collimator jaws to be kept centered around the beam orbit. In this manner, a better beam cleaning efficiency and machine protection can be provided at unprecedented higher beam energies and intensities. A collimator alignment algorithm is proposed to center the jaws automatically around the beam. The algorithm is based on successive approximation and takes into account a correction of the nonlinear BPM sensitivity to beam displacement and an asymmetry of the electronic channels processing the BPM electrode signals. A software implementation was tested with a prototype collimator in the Super Proton Synchrotron. This paper presents results of the tests along with some considerations for eventual operation in the LHC.

  18. Leap-frog-based BPM (LF-BPM) method for solving nanophotonic structures

    NASA Astrophysics Data System (ADS)

    Ayoub, Ahmad B.; Swillam, Mohamed A.

    2018-02-01

    In this paper, we propose an efficient approach to solve the BPM equation. By splitting the complex field into real and imaginary parts, the method is proved to be at least 30% faster than the conventional BPM. This method was tested on several optical components to test the accuracy.

  19. Preliminary evidence for good psychometric properties of the Norwegian version of the Brief Problems Monitor (BPM).

    PubMed

    Richter, Jörg

    2015-04-01

    Methods to assess intervention progress and outcome for frequent use are needed. To provide preliminary information about psychometric properties for the Norwegian version of the Brief Problems Monitor. Cronbach's alpha scores and intra-class correlation coefficients as indicators for internal consistency (reliability) and Pearson correlation coefficients between corresponding subscales of the long and short ASEBA form versions as well as multiple regression coefficients to explore the predictive power of the reduced item-set related to the corresponding scale-scores of the long version were calculated in large, representative data sets of Norwegian children and adolescents. Cronbach's alpha scores of the Norwegian version of the BPM subscales varied between 0.67 (attention BPM-youth) and 0.88 (attention BPM-teacher) and between 0.90 (BPM-youth) and 0.96 (BPM-teacher) for its total problem score. Corresponding subscales from the long versions and the BPM as well as the total problems scores were closely correlated with coefficients of high effect size (all r > 0.80). The variance of the items of the BPM explained about three-quarters or more of the variance in the corresponding subscales of the long version. The Norwegian BPM has good psychometric properties in terms of 1) being acceptable to good internal consistency and in terms of 2) regression coefficients of high effect size from the BPM items to the problem-scale scores of the long versions as validity indicators. Its use in clinical practice and research can be recommended.

  20. The relationship between admission heart rate and early prognosis in patients with ST-elevation myocardial infarction.

    PubMed

    Salwa, Paweł; Gorczyca-Michta, Iwona; Wożakowska-Kapłon, Beata

    2015-01-01

    Heart rate (HR) is a basic cardiovascular parameter. The relationship between HR and cardiovascular mortality and morbidity has been indicated in clinical trials and epidemiological studies. The evaluation of the relationship between HR upon hospital admission and the in-hospital prognosis in a group of patients with ST-elevation myocardial infarction (STEMI). The medical records of 927 patients were subject to retrospective analysis. The patients were classified on the basis of HR upon hospital admission: < 60 bpm (n = 75), 60-69 bpm (n = 169), 70-79 bpm (n = 245), 80-89 bpm (n = 172), 90-99 bpm (n = 134), and ≥ 100 bpm (n = 132). A group of patients with HR of 60-69 bpm on hospital admission (n = 169) constituted a reference group. Patients with atrioventricular blocks and arrhythmias were excluded from the analysis. Early mortality and co-existing diseases were evaluated in the study population. Patients with HR ≥ 90 bpm demonstrated heart failure symptoms considerably more often than patients with HR of 60-69 bpm (p = 0.0010). In-hospital mortality was significantly higher in patients with a HR of more than 90 bpm and bradycardia. The relationship between HR and cardiovascular mortality is shown with a J-shaped curve. HR is strictly correlated with early cardiovascular mortality in a population of patients with STEMI. The relationship between HR and early mortality is demonstrated by a J-shaped curve.

  1. Quality of life among patients after bilateral prophylactic mastectomy: A systematic review of patient reported outcomes

    PubMed Central

    Razdan, Shantanu N.; Patel, Vishal; Jewell, Sarah; McCarthy, Colleen M.

    2016-01-01

    Purpose Bilateral prophylactic mastectomy (BPM) is effective in reducing the risk of breast cancer in women with a well-defined family history of breast cancer or in women with BRCA 1 or 2 mutations. Evaluating patient-reported outcomes following BPM are thus essential for evaluating success of BPM from patient’s perspective. Our systematic review aimed to: (1) identify studies describing health-related quality of life (HRQOL) in patients following BPM with or without reconstruction; (2) assess the effect of BPM with or without reconstruction on HRQOL; and, (3) identify predictors of HRQOL post BPM. Methods We performed a systematic review of literature using the PRISMA guidelines. PubMed, Embase, PsycINFO, Web of Science, Scopus and Cochrane databases were searched. Results The initial search resulted in 1082 studies; 22 of these studies fulfilled our inclusion criteria. Post BPM, patients are satisfied with the outcomes and report high psychosocial well-being and positive body image. Sexual well-being and somatosensory function are most negatively affected. Vulnerability, psychological distress and preoperative cancer distress are significant negative predictors of quality of life and body image post BPM. Conclusion There is a paucity of high quality data on outcomes of different HRQOL domains post BPM. Future studies should strive to use validated and breast-specific PRO instruments for measuring HRQOL. This will facilitate shared decision-making by enabling surgeons to provide evidence-based answers to women contemplating BPM. PMID:26577764

  2. High resolution upgrade of the ATF damping ring BPM system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terunuma, N.; Urakawa, J.; /KEK, Tsukuba

    2008-05-01

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished in its first stage, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital downconversion techniques, digital signal processing, and also tests a new automatic gain error correction schema. The technical concept and realization, as well as preliminary results of beam studies are presented.

  3. Admission Systolic Blood Pressure Predicts the Number of Blood Pressure Medications at Discharge in Patients With Primary Intracerebral Hemorrhage.

    PubMed

    Khawaja, Ayaz M; Shiue, Harn; Boehme, Amelia K; Albright, Karen C; Venkatraman, Anand; Kumar, Gyanendra; Lyerly, Michael J; Hays-Shapshak, Angela; Mirza, Maira; Gropen, Toby I; Harrigan, Mark R

    2018-03-01

    Control of systolic blood pressure (SBP) after primary intracerebral hemorrhage improves outcomes. Factors determining the number of blood pressure medications (BPM) required for goal SBP<160 mm Hg at discharge are unknown. We hypothesized that higher admission-SBPs require a greater number of BPM for goal discharge-SBP<160 mm Hg, and investigated factors influencing this goal. We conducted a retrospective review of 288 patients who presented with primary intracerebral hemorrhage. Admission-SBP was obtained. Primary outcome was the number of BPM at discharge. Comparison was made between patients presenting with and without a history of hypertension, and patients discharged on <3 and ≥3 BPM. Patients with hypertension history had a higher median admission-SBP compared with those without (180 vs. 157 mm Hg, P=0.0001). In total, 133 of 288 (46.2%) patients were discharged on <3 BPM; 155/288 (53.8%) were discharged on ≥3 BPM. Hypertension history (P<0.0001) and admission-SBP (P<0.0001) predicted the number of BPM at discharge. In patients without hypertension history, every 10 mm Hg increase in SBP resulted in an absolute increase of 0.5 BPM at discharge (P=0.0011), whereas in those with hypertension, the absolute increase was 1.3 BPM (P=0.0012). In comparison with patients discharged on <3 BPM, patients discharged on ≥3 BPM were more likely to have a higher median admission-SBP, be younger in age, belong to the African-American race, have a history of diabetes, have higher median admission-National Institutes of Health Stroke Scale and modified Rankin Scale of 4 to 5 at discharge. An understanding of the factors influencing BPM at discharge may help clinicians better optimize blood pressure control both before and after discharge.

  4. Retrospective Evaluation of the Effect of Heart Rate on Survival in Dogs with Atrial Fibrillation.

    PubMed

    Pedro, B; Dukes-McEwan, J; Oyama, M A; Kraus, M S; Gelzer, A R

    2018-01-01

    Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown. Heart rate affects survival in dogs with chronic AF. Forty-six dogs with AF and 24-hour ambulatory recordings were evaluated. Retrospective study. Holter-derived HR variables were analyzed as follows: mean HR (meanHR, 24-hour average), minimum HR (minHR, 1-minute average), maximum HR (maxHR, 1-minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all-cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR <125 bpm versus ≥125 bpm. All 46 dogs had structural heart disease; 31 of 46 had congestive heart failure (CHF), 44 of 46 received antiarrhythmic drugs. Of 15 dogs with cardiac death, 14 had CHF. Median time to all-cause death was 524 days (Interquartile range (IQR), 76-1,037 days). MeanHR was 125 bpm (range, 62-203 bpm), minHR was 82 bpm (range, 37-163 bpm), maxHR was 217 bpm (range, 126-307 bpm). These were significantly correlated with all-cause and cardiac-related mortality. For every 10 bpm increase in meanHR, the risk of all-cause mortality increased by 35% (hazard ratio, 1.35; 95% CI, 1.17-1.55; P < 0.001). Median survival time of dogs with meanHR<125 bpm (n = 23) was significantly longer (1,037 days; range, 524-open) than meanHR ≥125 bpm (n = 23; 105 days; range, 67-267 days; P = 0.0012). Mean HR was independently associated with all-cause and cardiovascular mortality (P < 0.003). Holter-derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Difference between BPM reading one bunch and the average of multi-bunch in Booster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi Yang

    2004-08-18

    Differences caused by BPM reading one bunch and multi-bunch average need to be well understood before the beam parameters, such as the synchrotron tune, betatron tune, and chromaticity, are extracted from those BPM data. It is easy to perform such a study using numerical simulation other than modifying the BPM electronics.

  6. PAL-XFEL cavity beam position monitor pick-up design and beam test

    NASA Astrophysics Data System (ADS)

    Lee, Sojeong; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-01

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  7. Inflight workload assessment: comparison of subjective and physiological measurements.

    PubMed

    Lee, Yung-Hui; Liu, Bor-Shong

    2003-10-01

    Assessment of pilot workload during flight is an important aviation safety consideration. The aim of this study was to assess inflight pilot workload using both physiological and multidimensional subjective-ratings measurements (heart rate and NASA Task Load Index, respectively), comparing relative sensitivity during the four phases of flight: take-off, cruise, approach, and landing. Ten male pilots volunteered to participate in the trials, which took place in a Boeing 747-400 flight simulator. Electrocardiography was performed throughout the test using the portable Cardiovis ECG system. Mean heart rate (HR) and incremental heart rate (delta HR) were considered indices of physiological workload. Peak HR was observed during take-off (83.2 bpm) and landing (88.6 bpm); moreover, delta HR was also greatest (14.2 bpm and 18.8 bpm). The Task Load Index (TLX) scale revealed that mental and performance demands were essential components of workload during flight. In addition, temporal demand was an important component of workload during take-off and physical demand was significant during cruise. Analysis of correlation revealed that the delta HR is significantly related to TLX scores (r = 0.81, n = 40). Management of the individual sources of stress, which tend to become predominant during different flight phases, should be emphasized in periodic recurrent training. For example, a pilot must be trained to cope with the increased temporal stresses associated with take-off. In addition, the recommendations will be concerned with maintaining vigilance, task allocation between pilots, and inflight rest during long-haul cruise.

  8. Leveraging People-Related Maturity Issues for Achieving Higher Maturity and Capability Levels

    NASA Astrophysics Data System (ADS)

    Buglione, Luigi

    During the past 20 years Maturity Models (MM) become a buzzword in the ICT world. Since the initial Crosby's idea in 1979, plenty of models have been created in the Software & Systems Engineering domains, addressing various perspectives. By analyzing the content of the Process Reference Models (PRM) in many of them, it can be noticed that people-related issues have little weight in the appraisals of the capabilities of organizations while in practice they are considered as significant contributors in traditional process and organizational performance appraisals, as stressed instead in well-known Performance Management models such as MBQA, EFQM and BSC. This paper proposes some ways for leveraging people-related maturity issues merging HR practices from several types of maturity models into the organizational Business Process Model (BPM) in order to achieve higher organizational maturity and capability levels.

  9. CoNNeCT Baseband Processor Module

    NASA Technical Reports Server (NTRS)

    Yamamoto, Clifford K; Jedrey, Thomas C.; Gutrich, Daniel G.; Goodpasture, Richard L.

    2011-01-01

    A document describes the CoNNeCT Baseband Processor Module (BPM) based on an updated processor, memory technology, and field-programmable gate arrays (FPGAs). The BPM was developed from a requirement to provide sufficient computing power and memory storage to conduct experiments for a Software Defined Radio (SDR) to be implemented. The flight SDR uses the AT697 SPARC processor with on-chip data and instruction cache. The non-volatile memory has been increased from a 20-Mbit EEPROM (electrically erasable programmable read only memory) to a 4-Gbit Flash, managed by the RTAX2000 Housekeeper, allowing more programs and FPGA bit-files to be stored. The volatile memory has been increased from a 20-Mbit SRAM (static random access memory) to a 1.25-Gbit SDRAM (synchronous dynamic random access memory), providing additional memory space for more complex operating systems and programs to be executed on the SPARC. All memory is EDAC (error detection and correction) protected, while the SPARC processor implements fault protection via TMR (triple modular redundancy) architecture. Further capability over prior BPM designs includes the addition of a second FPGA to implement features beyond the resources of a single FPGA. Both FPGAs are implemented with Xilinx Virtex-II and are interconnected by a 96-bit bus to facilitate data exchange. Dedicated 1.25- Gbit SDRAMs are wired to each Xilinx FPGA to accommodate high rate data buffering for SDR applications as well as independent SpaceWire interfaces. The RTAX2000 manages scrub and configuration of each Xilinx.

  10. Using Shoulder Straps Decreases Heart Rate Variability and Salivary Cortisol Concentration in Swedish Ambulance Personnel.

    PubMed

    Karlsson, Kåre J; Niemelä, Patrik H; Jonsson, Anders R; Törnhage, Carl-Johan A

    2016-03-01

    Previous research has shown that paramedics are exposed to risks in the form of injuries to the musculoskeletal system. In addition, there are studies showing that they are also at increased risk of cardiovascular disease, cancer, and psychiatric diseases, which can partly be explained by their constant exposure to stress. The aim of this study is to evaluate whether the use of shoulder straps decreases physical effort in the form of decreased heart rate and cortisol concentration. A stretcher with a dummy was carried by 20 participants for 400 m on two occasions, one with and one without the shoulder straps. Heart rate was monitored continuously and cortisol samples were taken at intervals of 0 minutes, 15 minutes, 30 minutes, 45 minutes, and 60 minutes. Each participant was her or his own control. A significant decrease in heart rate and cortisol concentration was seen when shoulder straps were used. The median values for men (with shoulder straps) at 0 minutes was 78 bpm/21.1 nmol/L (heart rate/cortisol concentration), at 15 minutes was 85 bpm/16.9 nmol/L, and at 60 minutes was 76 bpm/15.7 nmol/L; for men without shoulder straps, these values were 78 bpm/21.9 nmol/L, 93 bpm/21.9 nmol/L, and 73 bpm/20.5 nmol/L. For women, the values were 85 bpm/23.3 nmol/L, 92 bpm/20.8 nmol/L, and 70 bpm/18.4 nmol/L and 84 bpm/32.4 nmol/L, 100 bpm/32.5 nmol/L, and 75 bpm/25.2 nmol/L, respectively. The use of shoulder straps decreases measurable physical stress and should therefore be implemented when heavy equipment or a stretcher needs to be carried. An easy way to ensure that staff use these or similar lifting aids is to provide them with personalized, well-adapted shoulder straps. Another better option would be to routinely sewn these straps into the staff's personal alarm jackets so they are always in place and ready to be used.

  11. Effect of station-specific alerting and ramp-up tones on firefighters' alarm time heart rates.

    PubMed

    MacNeal, James J; Cone, David C; Wistrom, Christopher L

    2016-11-01

    A number of long-term health effects are suffered by emergency responders, some influenced by psychological stress and fatigue. This study explored if stress and fatigue can be reduced by changing the method by which firefighters are alerted to emergency responses. Over several months, the method by which responders at a fire department were alerted was altered. Firefighter heart rates were measured first with standard alerting as a control (phase 1: all stations alerted simultaneously, with high-volume tones). The department then implemented station-specific (phase 2) and gradual volume ramp-up (phase 3) tone alerting, and heart rate increases were compared. The Fatigue Severity Score was used to examine firefighter fatigue, and the department administered a follow-up survey on personnel preferences. Individual heart rate increases (Δbpm) ranged from 2-48 bpm. Median increases were 7 bpm (IQR 4-11 bpm) during phase 1 (72.2% of alarms Δbpm<10), 7 bpm (IQR 5-12 bpm) during phase 2 (60.7% of alarms Δbpm<10), and 5 bpm (IQR 3-8 bpm) during phase 3 (82.7% of alarms Δbpm<10). The difference in medians was lower for phases 1 and 2 than for phase 3 (p = 0.0069), and more alarms in phase 3 resulted in increases of <10 bpm than in phase 2 (p = 0.0089). The Fatigue Severity Scale showed little variability: median scores 7 in phase 1, 8 in phase 2, and 7 in phase 3. Firefighters reported a strong preference for the "ramp-up" tones, and were roughly evenly divided between preferring alerting all stations simultaneously 24/7 (40% rating this 4 or 5 on a five-point Likert scale), station-specific alerting 24/7 (47.5%), or all stations during the day but station-specific at night (40%). Ramp-up tones were perceived as the best method to reduce stress during the day and overnight. Small but significant decreases in the amount of tachycardic response to station alerting are associated with simple alterations in alerting methods. Station-specific and ramp-up tones improve perceived working conditions for emergency responders.

  12. Performance of a Nanometer Resolution BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vogel, V; Hayano, H; Honda, Y

    2005-10-14

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. it is important to the ongoing ILC design effort to demonstrate that these tolerances can be achieved--ideally using beam-based stability measurements. It has been estimated that an RF cavity BPM with modern waveform processing could provide a position measurement resolution of less than one nanometer. Such a system could form the basis of the desired beam-based stability measurement, as well as be used for other specialized purposes. They have developed a high resolution RF cavity BPM and associated electronics.more » A triplet comprised of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. The three BPMs are rigidly mounted inside an alignment frame on six variable-length struts which can be used to move the BPMs in position and angle. they have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, they have been able to demonstrate a resolution of approximately 20 nm over a dynamic range of {+-} 20 {micro}m. They report on the progress of these ongoing tests.« less

  13. Time Series Spectroscopic and Photometric Observations of the Massive DAV BPM 37093

    NASA Astrophysics Data System (ADS)

    Nitta, Atsuko; Kepler, S. O.; Chene, Andre–Nicolas; Koester, D.; Provencal, J. L.; Sullivan, D. J.; Chote, Paul; Safeko, Ramotholo; Kanaan, Antonio; Romero, Alejandra; Corti, Mariela; Corti, Mariela; Kilic, Mukremin; Winget, D. E.

    2015-06-01

    BPM 37093 was the first of only a handful of massive (1.05+/-0.05 M⊙; Bergeron 2004;Koester & Allard 2000) white dwarf pulsators discovered (Kanaan et al. 1992). These stars are particularly interesting because the crystallized mass-fraction as a function of mass and temperature is poorly constrained by observation, yet this process adds 1-2 Gyr uncertainty in ages of the oldest white dwarf stars observed and hence, in the ages of associations that contain them (Abrikosov 1960; Kirzhnits 1960; Salpeter 1961). Last year, we discovered that ESO uses BPM 37093 as a standard star and extracted corresponding spectra from the public archive. The data suggested a large variation in the observed hydrogen line profiles that could potentially be due to pulsations, but the measurement did not reach a detection-quality threshold. To further explore this possibility, though, we obtained 4hrs of continuous time series spectroscopy of BPM 37093 with Gemini in the Northern Spring of 2014. We present our preliminary results from these data along with those from the accompanying time series photometric observations we gathered from Mt. John (New Zealand), South African Astronomical Observatory (SAAO), Panchromatic Robotic optical Monitoring and Polarimetry Telescopes (PROMPT) in Chile, and Complejo Astronomico El Leoncito (Argentina) to support the Gemini observations.

  14. Stimulatory effect on rat thymocytes proliferation and antimicrobial activity of two 6-(propan-2-yl)-4-methyl-morpholine-2,5-diones.

    PubMed

    Pavlovic, Voja; Djordjevic, Aleksandra; Cherneva, Emiliya; Yancheva, Denitsa; Smelcerovic, Andrija

    2012-03-01

    Recently we reported the identification and synthesis of cyclodidepsipeptides, 3,6-di(propan-2-yl)-4-methyl-morpholine-2,5-dione (PPM) and 3-(2-methylpropyl)-6-(propan-2-yl)-4-methyl-morpholine-2,5-dione (BPM), as potential precursors of enniatin B in Fusarium sporotrichioides. No data concerning biological activity of PPM and BPM have hitherto been published. The possible immunomodulatory effect and antimicrobial activity of PPM and BPM were investigated in this study, due to well known biological activities of enniatin B. The cytotoxicity effect of PPM and BPM on rat thymocytes demonstrated that increasing concentrations (0.1, 1, 10 μg/well) of PPM and BPM to cell culture, showed no significant effect on thymocytes toxicity. Simultaneously, incubation with studied cyclodidepsipeptides did not result with decreased mitochondrial membrane potential. Further, thymocytes exposure to increasing concentration of PPM and BPM was not able to induce significant reactive oxygen species (ROS) production in rat thymocytes. PPM and BPM administrations to cell culture in concentrations of 0.1 and 1 μg/well resulted with no significant increase of proliferative activity. However, significantly increased proliferative activity was detected with 10 μg of PPM (p<0.001) and BPM (p<0.05), as compared to their respective controls. The in vitro antimicrobial activity of PPM and BPM was tested against two Gram-positive and three Gram-negative bacteria. The results indicated that MIC values against tested strains ranged between 2.00 and 25.00 mg/ml. PPM showed much better activity against all tested bacteria in comparison with BPM. PPM was equally effective against both Gram-positive and Gram-negative bacteria, at the dose of 2.00 mg/ml. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Effects of smoking on heart rate at rest and during exercise, and on heart rate recovery, in young adults.

    PubMed

    Papathanasiou, George; Georgakopoulos, Dimitris; Papageorgiou, Effie; Zerva, Efthimia; Michalis, Lampros; Kalfakakou, Vasiliki; Evangelou, Angelos

    2013-01-01

    There is an established link between smoking, abnormal heart rate (HR) values, and impaired cardiovascular health in middle-aged or older populations. The purpose of this study was to examine the effects of smoking on resting HR and on HR responses during and after exercise in young adults. A sample of 298 young adults (159 men), aged 20-29 years old, were selected from a large population of health-science students based on health status, body mass index, physical activity, and smoking habit. All subjects underwent a maximal Bruce treadmill test and their HR was recorded during, at peak, and after termination of exercise. Smokers had significantly higher resting HR values than non-smokers. Both female and male smokers showed a significantly slower HR increase during exercise. Female smokers failed to reach their age-predicted maximum HR by 6.0 bpm and males by 3.6 bpm. The actual maximum HR achieved (HRmax) was significantly lower for both female smokers (191.0 bpm vs.198.0 bpm) and male smokers (193.2 bpm vs.199.3 bpm), compared to non-smokers. Heart rate reserve was also significantly lower in female (114.6 bpm vs. 128.1 bpm) and male smokers (120.4 bpm vs. 133.0 bpm). During recovery, the HR decline was significantly attenuated, but only in female smokers. Females had a higher resting HR and showed a higher HR response during sub-maximal exercise compared to males. Smoking was found to affect young smokers' HR, increasing HR at rest, slowing HR increase during exercise and impairing their ability to reach the age-predicted HRmax. In addition, smoking was associated with an attenuated HR decline during recovery, but only in females.

  16. Evaluation of in-hospital electrocardiography versus 24-hour Holter for rate control in dogs with atrial fibrillation.

    PubMed

    Gelzer, A R; Kraus, M S; Rishniw, M

    2015-07-01

    To determine if the in-clinic ECG-derived heart rate could predict the at-home Holter-derived 24-hour average heart rate (Holter24h ), and whether it is useful to identify slow versus fast atrial fibrillation in dogs. 82 pairs of 1-minute ECGs and 24-hour Holter recordings were acquired in 34 dogs with atrial fibrillation. The initial 24-hour Holter was used to test if the ECG heart rate can identify dogs with "slow" versus "fast" atrial fibrillation based on a Holter24h threshold value of 140 bpm. ECG heart rate overestimated Holter24h by 26 bpm (95% CI: 3 bpm, 48 bpm; P < 0 · 015) with a 95% limit of agreement of -21 to 83 bpm. The in-clinic ECG-derived heart rate Ä155 bpm had a sensitivity of 73% and a specificity of 100% for identifying a Holter24h HR Ä140 bpm; an in-clinic ECG-derived HR <160 bpm had a sensitivity and specificity of 91% each. In-clinic ECG assessment of heart rate in dogs with atrial fibrillation does not reliably predict the heart rate in their home environment. However, an in-clinic heart rate greater than 155 bpm is useful in identifying "fast" atrial fibrillation, allowing clinicians to stratify which case may benefit from antiarrhythmic therapy. © 2015 British Small Animal Veterinary Association.

  17. Synthesis, structure, and magnetic properties of regular alternating μ-bpm/di-μ-X copper(II) chains (bpm = 2,2'-bipyrimidine; X = OH, F).

    PubMed

    Marino, Nadia; Armentano, Donatella; De Munno, Giovanni; Cano, Joan; Lloret, Francesc; Julve, Miguel

    2012-04-02

    The preparation and X-ray crystal structure of four 2,2'-bipyrimidine (bpm)-containing copper(II) complexes of formula {[Cu(2)(μ-bpm)(H(2)O)(4)(μ-OH)(2)][Mn(H(2)O)(6)](SO(4))(2)}(n) (1), {[Cu(2)(μ-bpm)(H(2)O)(4)(μ-OH)(2)]SiF(6)}(n) (2), {Cu(2)(μ-bpm)(H(2)O)(2)(μ-F)(2)F(2)}(n) (3), and [Cu(bpm)(H(2)O)(2)F(NO(3))][Cu(bpm)(H(2)O)(3)F]NO(3)·2H(2)O (4) are reported. The structures of 1-3 consist of chains of copper(II) ions with regular alternation of bis-bidentate bpm and di-μ-hydroxo (1 and 2) or di-μ-fluoro (3) groups, the electroneutrality being achieved by either hexaaqua manganese(II) cations plus uncoordinated sulfate anions (1), uncoordinated hexafluorosilicate anions (2), or terminally bound fluoride ligands (3). Each copper(II) ion in 1-4 is six-coordinated in elongated octahedral surroundings. 1 and 2 show identical, linear chain motifs with two bpm-nitrogen atoms and two hydroxo groups building the equatorial plane at each copper(II) ion and the axial position being filled by water molecules. In the case of 3, the axial sites at the copper atom are occupied by a bpm-nitrogen atom and a bis-monodentate fluoride anion, producing a "step-like" chain motif. The values of the angle at the hydroxo and fluoro bridges are 94.11(6) (1), 94.75(4) (2), and 101.43(4)° (3). In each case, the copper-copper separation through the bis-bidentate bpm [5.428(1) (1), 5.449(1) (2), and 5.9250(4) Å (3)] is considerably longer than that through the di-μ-hydroxo [2.8320(4) (1) and 2.824(1) Å (2)] or di-μ-fluoro [3.3027(4) Å (3)] bridges. Compound 4 is a mononuclear species whose structure is made up of neutral [Cu(bpm)(H(2)O)(2)F(NO(3))] units, [Cu(bpm)(H(2)O)(3)F](+) cations, uncoordinated nitrate anions, and crystallization water molecules, giving rise to a pseudo-helical, one-dimensional (1D) supramolecular motif. The magnetic properties of 1-3 have been investigated in the temperature range 1.9-300 K. Relatively large, alternating antiferro- [J = -149 (1) and -141 cm(-1) (2) across bis-bidentate bpm] and ferromagnetic [αJ = +194 (1) and +176 cm(-1) (2) through the dihydroxo bridges] interactions occur in 1 and 2 [the Hamiltonian being defined as H = -J∑(i=1)(n/2) (S(2i)·S(2i-1) - αS(2i)·S(2i+1))]. These values compare well with those previously reported for parent examples. Two weak intrachain antiferromagnetic interactions [J = -0.30 and αJ = -8.1 cm(-1) across bpm and the di-μ-fluoro bridges, respectively] whose values were substantiated by density functional theory (DFT)-type calculations occur in 3.

  18. Fundamentals of Mold Free Casting: Experimental and Computational Studies

    NASA Technical Reports Server (NTRS)

    Tryggvason, Gretar; Ceccio, Steven

    1997-01-01

    Researchers are developing the technology of 'Ballistic Particle Manufacturing' (BPM) in which individual drops are precisely layered onto a substrate, and the drops are deposited so as to prevent splatting. These individual drops will ultimately be combined to form a net-shape, three-dimensional object. Our understanding of controlled drop deposition as applied to BPM is far from complete. Process parameters include the size and temperature of the liquid metal drop, its impact velocity and trajectory, and the condition and temperature of the substrate. Quantitative knowledge of the fluid mechanics and heat transfer of drop deposition and solidification are necessary to fully optimize the manufacturing process and to control the material microstructure of the final part. The object of this study is to examine the dynamics of liquid metal drops as they impinge upon a solid surface and solidify under conditions consistent with BPM (i.e. conditions which produce non-splatting drops). A program of both numerical simulations and experiments will be conducted. Questions this study will address include the following: How do the deformation and solidification of the drop depend on the properties of the fluid drop and the solid substrate? How does the presence of previously deposited drops affect the impingement and solidification process? How does the impingement of the new drop affect already deposited material? How does the cooling rate and solidification of the drops influence the material microstructure?

  19. BPMs with Precise Alignment for TTF2

    NASA Astrophysics Data System (ADS)

    Noelle, D.; Priebe, G.; Wendt, M.; Werner, M.

    2004-11-01

    Design and technology of the new, standardized BPM-system for the warm sections of the TESLA Test Facility phase II (TTF2) are presented. Stripline- and button-BPM pickups are read-out with an upgraded version of the AM/PM BPM-electronics of TTF1. The Stripline-BPMs are fixed inside the quadrupole magnets. A stretched wire measurement was used to calibrate the electrical axis of the BPM wrt. to the magnetic axis of the quadrupole.

  20. ACCELERATORS: Beam based alignment of the SSRF storage ring

    NASA Astrophysics Data System (ADS)

    Zhang, Man-Zhou; Li, Hao-Hu; Jiang, Bo-Cheng; Liu, Gui-Min; Li, De-Ming

    2009-04-01

    There are 140 beam position monitors (BPMs) in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring used for measuring the closed orbit. As the BPM pickup electrodes are assembled directly on the vacuum chamber, it is important to calibrate the electrical center offset of the BPM to an adjacent quadrupole magnetic center. A beam based alignment (BBA) method which varies individual quadrupole magnet strength and observes its effects on the orbit is used to measure the BPM offsets in both the horizontal and vertical planes. It is a completely automated technique with various data processing methods. There are several parameters such as the strength change of the correctors and the quadrupoles which should be chosen carefully in real measurement. After several rounds of BBA measurement and closed orbit correction, these offsets are set to an accuracy better than 10 μm. In this paper we present the method of beam based calibration of BPMs, the experimental results of the SSRF storage ring, and the error analysis.

  1. Postural tachycardia syndrome and inappropriate sinus tachycardia: role of autonomic modulation and sinus node automaticity.

    PubMed

    Nwazue, Victor C; Paranjape, Sachin Y; Black, Bonnie K; Biaggioni, Italo; Diedrich, André; Dupont, William D; Robertson, David; Raj, Satish R

    2014-04-10

    Inappropriate sinus tachycardia (IST) and postural tachycardia syndrome (POTS) are 2 disorders characterized by sinus tachycardia. It is debated whether the pathophysiology of IST and POTS results from abnormal autonomic regulation or abnormal sinus node function. We hypothesized that intrinsic heart rate (IHR) after autonomic blockade would be increased in patients with IST but not POTS. We enrolled 48 POTS patients, 8 IST patients, and 17 healthy control (HC) subjects. Intravenous propranolol and atropine were given to block the sympathetic and parasympathetic limbs of the autonomic nervous system in order to determine the IHR. Patients with IST have a higher sympathetic contribution to heart rate when compared with POTS patients (31±13 bpm versus 12±7 bpm, P<0.001) and HC (8±4 bpm; P<0.001) and a trend to less parasympathetic contribution than POTS and HC (IST: 31±11 bpm versus POTS: 46±11 bpm versus HC: 48±11 bpm, ANOVA P=0.108). IHR was not significantly different between IST and either POTS or HC (IST: 111±11 bpm versus POTS: 108±11 bpm versus HC: 106±12 bpm, ANOVA P=0.237). IST patients have more sympathetic tone when compared with either POTS or HC, but IST patients do not have abnormal sinus node automaticity. These data suggest that the treatment of IST and POTS should focus on sympatholysis, reserving sinus node modification for patients with continued debilitating symptoms after beta-blockade and possibly ivabradine. http://clinicaltrials.gov/. Unique identifier: NCT00262470.

  2. High Resolution BPM Upgrade for the ATF Damping Ring at KEK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eddy, N.; Briegel, C.; Fellenz, B.

    2011-08-17

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital down-conversion techniques, digital signal processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented. The next generation of linear colliders require ultra-low vertical emittance of <2 pm-rad. The damping ring at the KEK Accelerator Test Facilitymore » (ATF) is designed to demonstrate this mission critical goal. A high resolution beam position monitor (BPM) system for the damping ring is one of the key tools for realizing this goal. The BPM system needs to provide two distnict measurements. First, a very high resolution ({approx}100-200nm) closed-orbit measurement which is averaged over many turns and realized with narrowband filter techniques - 'narrowband mode'. This is needed to monitor and steer the beam along an optimum orbit and to facilitate beam-based alignment to minimize non-linear field effects. Second, is the ability to make turn by turn (TBT) measurements to support optics studies and corrections necessary to achieve the design performance. As the TBT measurement necessitates a wider bandwidth, it is often referred to as 'wideband mode'. The BPM upgrade was initiated as a KEK/SLAC/FNAL collaboration in the frame of the Global Design Initiative of the International Linear Collider. The project was realized and completed using Japan-US funds with Fermilab as the core partner.« less

  3. Linac coherent light source (LCLS) undulator RF BPM system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Waldschmidt, G.; Morrison, L.

    2006-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, andmore » prototype test results.« less

  4. Linac Coherent Light Source Undulator RF BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.M.; Morrison, L.H.; Waldschmidt, G.J.

    2007-04-17

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, andmore » prototype test results.« less

  5. Performance evaluation of BPM system in SSRF using PCA method

    NASA Astrophysics Data System (ADS)

    Chen, Zhi-Chu; Leng, Yong-Bin; Yan, Ying-Bing; Yuan, Ren-Xian; Lai, Long-Wei

    2014-07-01

    The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related information was extracted before the evaluation of the BPM performance. A series of studies had been made in the Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved to be an effective and robust method in the performance evaluations of our BPM system.

  6. Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm.

    PubMed

    Pansini, Vittorio; Remy-Jardin, Martine; Tacelli, Nunzia; Faivre, Jean-Baptiste; Flohr, Thomas; Deken, Valérie; Duhamel, Alain; Remy, Jacques

    2008-10-01

    To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P=0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P

  7. Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate.

    PubMed

    Machida, Haruhiko; Lin, Xiao-Zhu; Fukui, Rika; Shen, Yun; Suzuki, Shigeru; Tanaka, Isao; Ishikawa, Takuya; Tate, Etsuko; Ueno, Eiko

    2015-02-01

    We retrospectively investigated the effect of the motion correction algorithm (MCA) on image quality and interpretability by heart rate (HR) in coronary CT angiography (CCTA). For 105 patients (6 HR groups) undergoing CCTA, 2 readers independently graded the image quality of the 4 major coronary arteries reconstructed with and without MCA at diastole with HR ≤64 bpm and at systole and diastole ≥65 bpm using a 5-point scale. For each HR group and cardiac phase, we compared per-vessel and per-segment image quality using Wilcoxon signed rank test and percentages of interpretable image quality (scores 3-5) among without MCA at diastole with HR ≤64 bpm, as a reference, with MCA at diastole ≤69 bpm and at systole 70-79 bpm using the chi-square test. The motion correction algorithm reconstruction provided similar or better image quality and interpretability in all groups, with 96-100 % per-vessel (P = 0.008 for the right coronary artery; otherwise, P > 0.05) and 99 % per-segment interpretable image quality (P = 0.0002) at diastole with HR ≤69 bpm and at systole 70-79 bpm compared to the reference (88-100 and 97 %, respectively). MCA reconstruction preserved image quality and interpretability of CCTA with HR ≤79 bpm.

  8. Reduction of resting heart rate with antianginal drugs: review and meta-analysis.

    PubMed

    Cucherat, Michel; Borer, Jeffrey S

    2012-07-01

    The benefit of heart rate (HR) reduction in patients with stable coronary artery disease is well demonstrated for symptom prevention and relief, and benefits on outcomes are being actively investigated. We aimed to quantify the reduction in resting HR induced by 5 antianginal drugs frequently used for symptom prevention (diltiazem, verapamil, atenolol, metoprolol, and ivabradine) in stable angina pectoris. We identified studies published between 1966 and 2007 in PubMed, Embase, and the Cochrane database and reviewed the bibliographies to locate additional studies. Eligible studies were double-blind, randomized, placebo-controlled trials in patients with stable angina. Trials were combined using weighted mean difference and fixed-effect model meta-analysis. The main outcome measure was resting HR at the study end. For diltiazem, resting HR reduction versus placebo ranged from -0.08 beats per minute (bpm) [95% confidence interval (CI) -1.5 to +1.4] for 120 mg/d to -8.0 bpm (95% CI, -11.1 to -5.0) with 360 mg/d. For sustained-release diltiazem, there was a reduction in resting HR of -4.5 bpm (95% CI, -6.4 to -2.5), with no dose-response relationship (heterogeneity P = 0.62). Resting HR reductions for the other agents were -3.2 bpm (95% CI, -5.1 to -1.3) for verapamil (with no dose-response relationship, heterogeneity P = 0.87); -19.0 bpm (95% CI, -20.4 to -17.6) for atenolol; -13.2 bpm (95% CI, -14.7 to -11.7) for metoprolol (with greater reductions for 150 mg/d and long-acting 190 mg/d); and between -9.3 bpm (95% CI, -13.8 to -4.8) and -19.6 bpm (95% CI, -23.8 to -15.4) for ivabradine. Ivabradine, atenolol, and metoprolol give similar reductions in resting HR (-10 to -20 bpm), whereas verapamil and diltiazem produce only marginal reductions (<10 bpm).

  9. [Heart rate control in chronic heart failure patients received cardiovascular implantable electronic device therapy: effects of optimized medication].

    PubMed

    Gao, Y; Liang, Y C; Yu, H B; Yan, X L; Xu, B G; Liu, R; Wang, N; Xu, G Q; Wang, Z L

    2018-03-24

    Objective: To investigate the heart rate control situation of chronic heart failure (CHF) patients who received cardiovascular implantable electronic device (CIED) therapy, and to assess the heart rate control efficacy by optimized medication adjustment. Methods: We performed a perspective study in heart failure with reduced left ventricular ejection fraction (HFrEF) patients who received CIED according to guideline recommendations, patients were enrolled from January 2012 to January 2017. Resting heart rate (RHR) recorded by electrocardiogram after 10 minutes' rest and medication usage within 1 month were recorded at baseline. RHR less than 70 beats per minute (bpm) was regarded as well controlled. β-receptor blockers and (or) ivabradine would be added in patients whose RHR were over 70 bpm. RHR after optimized medication adjustment was recorded during follow-up period. Results: One hundred and fifty patients were included in this study with average RHR (80.6±11.9) bpm. RHR was<70 bpm in 27.3% (41/150) patients at baseline and β-receptor blockers was underused in 80.7% patients (88/109) whose RHR was>70 bpm. The overall RHR decreased to (73.1±10.4) bpm and percent of patients with RHR<70 bpm increased to 70.0% (105/150) after up-titration of β-receptor blockers compared to baseline (χ 2 =52.958, P< 0.001). Ivabradine was added in the rest 45 patients and RHR was<70 bpm in 43 out of 45 patients after ivabradine use. The overall RHR decreased to (67.1±2.7) bpm and percent of RHR<70 bpm significantly increased to 98.7% (148/150) (χ 2 =44.504, P< 0.001 vs. up-titration of β-receptor blockers only). Conclusion: RHR in CHF patients who received CIED therapy is not ideally controlled in this patient cohort, individual up-titration ofβ-receptor blockers and ivabradine use may help to optimize RHR in these patients.

  10. Association between resting heart rate, metabolic syndrome and cardiorespiratory fitness in Korean male adults.

    PubMed

    Kang, Seol-Jung; Ha, Gi-Chul; Ko, Kwang-Jun

    2017-06-01

    The present study aimed to investigate the association between metabolic syndrome and cardiorespiratory fitness according to resting heart rate of Korean male adults. A total of 11,876 male adults aged 20-65 years who underwent health examinations from 2010 to 2015 at a National Fitness Centre in South Korea were included. Subjects' resting heart rate, cardiorespiratory fitness (VO 2 max), and metabolic syndrome parameters were collected. The subjects were divided into 5 categories (<60 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and ≥90 bpm) of resting heart rate for further analysis. We found that elevated resting heart rate was positively associated with body mass index, systolic blood pressure, diastolic blood pressure, triglycerides, and fasting blood glucose levels ( p  < 0.001, respectively); in contrast, elevated resting heart rate was inversely associated with VO 2 max ( p  < 0.001). When resting heart rate of subjects was categorized into quintiles and analysed, the results showed that the relative risk of metabolic syndrome was 1.53-fold higher (95% CI, 1.34 to 1.82) in the range of 60-69 beats per minute (bpm), 2.08-fold higher (95% CI, 1.77 to 2.45) in the range of 70-79 bpm, 2.28-fold higher (95% CI, 1.73 to 3.00) in the range of 80-89 bpm, and 2.61-fold higher (95% CI, 1.62 to 4.20) in the range of ≥90 bpm, compared to those <60 bpm; this indicated that as resting heart rate increased, the relative risk of metabolic syndrome also increased. Resting heart rate of male adults was found to be associated with cardiorespiratory fitness; the risk factors for metabolic syndrome and relative risk of metabolic syndrome increased as resting heart rate increased.

  11. [Time-dependent heart rate variability in the head-up tilt test in children with postural orthostatic tachycardia syndrome].

    PubMed

    Ran, Jing; Wang, Cheng; Zou, Run-Mei; Wu, Li-Jia; Lin, Ping; Li, Fang; Xu, Yi

    2015-10-01

    To study the time-dependent heart rate (HR) variability in the head-up tilt test (HUTT) in children with postural orthostatic tachycardia syndrome (POTS) and to explore the HR diagnostic criteria for POTS in children. A retrospective analysis was performed on the clinical data of 105 children diagnosed with POTS with HR≥120 beats per minute (bpm) within the first 10 minutes of HUTT between January 2007 and December 2014. Their HR variability within the first 10 minutes of HUTT was analyzed. The HR of children with POTS increased gradually from the supine position to a 60° head-up tilt position, and the increase in HR was 24±12 bpm at the beginning of HUTT, 30±14 bpm at 3 minutes of HUTT, 32±13 bpm at 5 minutes of HUTT, and 38±12 bpm at 10 minutes of HUTT. The average maximal HR increase within the first 10 minutes of HUTT was 43±10 bpm. In children with POTS, the HR variability gradually increases with time, and therefore, it is suggested that HR increase ≥40 bpm is more suitable for diagnosis of POTS in children.

  12. Modulation of Ca(v)3.1 T-type Ca2+ channels by the ran binding protein RanBPM.

    PubMed

    Kim, Taehyun; Kim, Sunoh; Yun, Hyung-Mun; Chung, Kwang Chul; Han, Ye Sun; Shin, Hee-Sup; Rhim, Hyewhon

    2009-01-02

    In order to study the currently unknown cellular signaling pathways of Ca(v)3.1 T-type Ca(2+) channels (Ca(v)3.1 channels), we performed a yeast two-hybrid screening using intracellular domains of Ca(v)3.1 alpha1 subunit as bait. After screening the human brain cDNA library, several proteins, including RanBPM, were identified as interacting with Ca(v)3.1 channels. RanBPM was found to bind to the cytoplasmic intracellular loop between transmembrane domains I and II of Ca(v)3.1 channels. Using whole-cell patch-clamp techniques, we found that Ca(v)3.1 currents were increased by the expression of RanBPM in HEK293/Ca(v)3.1 cells. We next examined whether RanBPM affected the biophysical properties and plasma membrane expression of Ca(v)3.1 channels. Furthermore, we showed that the PKC activator inhibited Ca(v)3.1 currents, an effect that was abolished by the expression of RanBPM. These results suggest that RanBPM could be a key regulator of Ca(v)3.1 channel-mediated signaling pathways.

  13. Law Enforcement Head-Borne Personal Protective Equipment Hearing Attenuation

    DTIC Science & Technology

    2009-04-01

    thus allowing for a binaural recording to be captured. The BOB was placed on a manual turntable to allow the BOB to be rotated along the azimuth...listed in the Appendix. Each movement should be conducted 8 times at a rate of 50 beats per minute (BPM) and 80 BPM; this will be defined as slow...APPENDIX FABRIC NOISE TEST MOVEMENTS AND SPEEDS The below movements must be performed at a rate of 50 beats per minute (BPM) and 80 BPM: Movement

  14. Development of the PEFP's beam line BPM

    NASA Astrophysics Data System (ADS)

    Ryu, Jin-Yeong; Kwon, Hyeok-Jung; Jang, Ji-Ho; Kim, Han-Sung; Seol, Kyung-Tae; Cho, Yong-Sub

    2013-01-01

    The Proton Engineering Frontier Project (PEFP) has 20-MeV and 100-MeV beam lines to supply proton beams to users. A stripline-type Beam Position Monitor (BPM) was designed and fabricated in order to measure the beam's position in the beam line. The RF properties of the BPM were measured and compared with the simulation. After the sensitivity of the BPM at a test stand had been obtained, we performed a beam test in a test beam line of the PEFP 20-MeV proton linac.

  15. Comparing in vitro and in vivo virulence phenotypes of Burkholderia pseudomallei type G strains.

    PubMed

    Lewis, Eric R G; Kilgore, Paul B; Mott, Tiffany M; Pradenas, Gonzalo A; Torres, Alfredo G

    2017-01-01

    Burkholderia pseudomallei (Bpm) is a saprophytic rod-shaped gram-negative bacterium and the causative agent of melioidosis. This disease has previously been described as endemic in areas such as northern Australia and Southeast Asia, but, more recently, a better understanding of the epidemiology of melioidosis indicated that the disease is distributed worldwide, including regions of the Americas and Africa. A 16S-23S rDNA internal transcribed spacer (ITS) typing system has been developed for Bpm and has revealed that ITS types C, E, and hybrid CE are mainly associated with Australia and Southeast Asia while type G strains are more associated with cases of melioidosis in the Western Hemisphere. The purpose of the current study was to determine the in vitro and in vivo virulence profiles of the understudied Bpm type G strains Ca2009, Ca2013a, Mx2013, and 724644 and compared such phenotypes to the commonly studied Bpm type C strain K96243. We evaluated virulence by measuring invasion/uptake and survival of these Bpm strains in murine respiratory epithelial LA-4 cells and alveolar macrophage MH-S cells using different multiplicity of infections (MOIs of 1 and 10). We also calculated the lethal dose 50 values (LD50) in BALB/c mice that were inoculated intranasally with either Ca2009, Ca2013a, or Mx2013. Overall, the virulence and lethality phenotypes of Bpm type G strains were similar to the Bpm type C strain K96243. Additional comparative analyses between the Bpm ITS types may lead to a better understanding of the contribution of the ITS type to the epidemiology and ecology of Bpm strains.

  16. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

    PubMed

    Morsbach, Fabian; Gordic, Sonja; Desbiolles, Lotus; Husarik, Daniela; Frauenfelder, Thomas; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian

    2014-08-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

  17. Comparing in vitro and in vivo virulence phenotypes of Burkholderia pseudomallei type G strains

    PubMed Central

    Mott, Tiffany M.; Pradenas, Gonzalo A.

    2017-01-01

    Burkholderia pseudomallei (Bpm) is a saprophytic rod-shaped gram-negative bacterium and the causative agent of melioidosis. This disease has previously been described as endemic in areas such as northern Australia and Southeast Asia, but, more recently, a better understanding of the epidemiology of melioidosis indicated that the disease is distributed worldwide, including regions of the Americas and Africa. A 16S-23S rDNA internal transcribed spacer (ITS) typing system has been developed for Bpm and has revealed that ITS types C, E, and hybrid CE are mainly associated with Australia and Southeast Asia while type G strains are more associated with cases of melioidosis in the Western Hemisphere. The purpose of the current study was to determine the in vitro and in vivo virulence profiles of the understudied Bpm type G strains Ca2009, Ca2013a, Mx2013, and 724644 and compared such phenotypes to the commonly studied Bpm type C strain K96243. We evaluated virulence by measuring invasion/uptake and survival of these Bpm strains in murine respiratory epithelial LA-4 cells and alveolar macrophage MH-S cells using different multiplicity of infections (MOIs of 1 and 10). We also calculated the lethal dose 50 values (LD50) in BALB/c mice that were inoculated intranasally with either Ca2009, Ca2013a, or Mx2013. Overall, the virulence and lethality phenotypes of Bpm type G strains were similar to the Bpm type C strain K96243. Additional comparative analyses between the Bpm ITS types may lead to a better understanding of the contribution of the ITS type to the epidemiology and ecology of Bpm strains. PMID:28414823

  18. Effects of renal sympathetic denervation on heart rate and atrioventricular conduction in patients with resistant hypertension.

    PubMed

    Ukena, Christian; Mahfoud, Felix; Spies, Aline; Kindermann, Ingrid; Linz, Dominik; Cremers, Bodo; Laufs, Ulrich; Neuberger, Hans-Ruprecht; Böhm, Michael

    2013-09-10

    Renal sympathetic denervation (RDN) reduces sympathetic activity and blood pressure (BP) in patients with resistant hypertension. The present study aimed to investigate the effects of RDN on HR and other electrocardiographic parameters. 136 patients aged 62.2 ± 0.8 years (58% male, BP 177 ± 2/93 ± 1 mmHg) with resistant hypertension underwent RDN. BP and a 12-lead electrocardiogram (ECG) were recorded before, 3 months (n=127), and 6 months (n=88) after RDN. After 3 months (3M) and 6 months (6M), systolic BP was reduced by 25.5 ± 2.4 mmHg (p<0.0001) and 28.1 ± 3 mmHg (p<0.0001). HR at baseline was 66.1 ± 1 beats per minute (bpm) and was reduced by 2.6 ± 0.8 bpm after 3 months (p=0.001) and 2.1 ± 1.1 bpm after 6 months (p=0.046). Patients with HR at baseline between 60-71 bpm and ≥ 71 bpm had a reduction of 2.9 ± 7.6 bpm (p=0.008) and 9.0 ± 8.6 bpm (p<0.0001), respectively, whereas in patients with baseline HR<60 bpm HR slightly increased after 3 months (2.7 ± 8.4 bpm; p=0.035). Neither baseline HR nor change of HR correlated with the reduction of systolic BP. The PR interval was prolonged by 11.3 ± 2.5 ms (p<0.0001) and 10.3 ± 2.5 ms (p<0.0001) at 3 and 6 months after RDN, respectively. Renal sympathetic denervation reduced heart rate and the PR interval as indicators of cardiac autonomic activity. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Respiratory rates measured by a standardised clinical approach, ward staff, and a wireless device.

    PubMed

    Granholm, A; Pedersen, N E; Lippert, A; Petersen, L F; Rasmussen, L S

    2016-11-01

    Respiratory rate is among the first vital signs to change in deteriorating patients. The aim was to investigate the agreement between respiratory rate measurements by three different methods. This prospective observational study included acutely admitted adult patients in a medical ward. Respiratory rate was measured by three methods: a standardised approach over 60 s while patients lay still and refrained from talking, by ward staff and by a wireless electronic patch (SensiumVitals). The Bland-Altman method was used to compare measurements and three breaths per minute (BPM) was considered a clinically relevant difference. We included 50 patients. The mean difference between the standardised approach and the electronic measurement was 0.3 (95% CI: -1.4 to 2.0) BPM; 95% limits of agreement were -11.5 (95% CI: -14.5 to -8.6) and 12.1 (95% CI: 9.2 to 15.1) BPM. Removal of three outliers with huge differences lead to a mean difference of -0.1 (95% CI: -0.7 to 0.5) BPM and 95% limits of agreement of -4.2 (95% CI: -5.3 to -3.2) BPM and 4.0 (95% CI: 2.9 to 5.0) BPM. The mean difference between staff and electronic measurements was 1.7 (95% CI: -0.5 to 3.9) BPM; 95% limits of agreement were -13.3 (95% CI: -17.2 to -9.5) BPM and 16.8 (95% CI: 13.0 to 20.6) BPM. A concerning lack of agreement was found between a wireless monitoring system and a standardised clinical approach. Ward staff's measurements also seemed to be inaccurate. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Designing Process Improvement of Finished Good On Time Release and Performance Indicator Tool in Milk Industry Using Business Process Reengineering Method

    NASA Astrophysics Data System (ADS)

    Dachyar, M.; Christy, E.

    2014-04-01

    To maintain position as a major milk producer, the Indonesian milk industry should do some business development with the purpose of increasing customer service level. One strategy is to create on time release conditions for finished goods which will be distributed to customers and distributors. To achieve this condition, management information systems of finished goods on time release needs to be improved. The focus of this research is to conduct business process improvement using Business Process Reengineering (BPR). The deliverable key of this study is a comprehensive business strategy which is the solution of the root problems. To achieve the goal, evaluation, reengineering, and improvement of the ERP system are conducted. To visualize the predicted implementation, a simulation model is built by Oracle BPM. The output of this simulation showed that the proposed solution could effectively reduce the process lead time and increase the number of quality releases.

  1. Towards a better understanding of honeycomb alternating magnetic networks.

    PubMed

    Marino, Nadia; Armentano, Donatella; De Munno, Giovanni; Lloret, Francesc; Cano, Joan; Julve, Miguel

    2015-06-28

    Two new two-dimensional homometallic compounds {[M2(bpm)(ox)2]n·5nH2O} with M = Co(II) (1) and Zn(II) (2) and the mononuclear nickel(II) complex [Ni(bpm)2(ox)]·2H2O (3) [bpm = 2,2'-bipyrimidine and ox = oxalate] have been prepared and structurally characterized. 1 and 2 are isostructural compounds whose structures are made up of oxalate-bridged M(II) cations cross-linked by bis-bidentate bpm molecules to afford a honeycomb layered network extending in the crystallographic ab plane. The layers are eclipsed along the crystallographic c axis and show graphitic-like interactions between the bpm rings. The three-dimensional supramolecular network deriving from such interactions is characterized by hexagonal-shaped channels extending in the same direction. Each M(II) ion in 1 and 2 is tris-chelated with four oxygen atoms from two oxalate groups and two bpm-nitrogen atoms building a distorted octahedral surrounding. The reduced values of the angles subtended by the bis-chelating bpm [77.69(8) (1) and 76.59(8)° (2)] and oxalate [79.69(6) (1) and 80.01(5)° (2)] are the main factors accounting for this distortion. The values of the metal-metal separation through bridging bpm are 5.6956(7) (1) and 5.7572(9) Å (2), whereas those across the bis-bidentate oxalate are 5.4306(4) (1) and 5.4058(5) Å (2). 3 is a neutral mononuclear nickel(II) complex where each metal ion is six-coordinate with four nitrogen atoms from two bpm ligands in a cis arrangement and two oxalate-oxygen atoms building a somewhat distorted octahedral surrounding. The values of the angles subtended at the nickel(II) ion by bpm and oxalate are 78.14(4) and 80.95(5)°, respectively. The magnetic properties of 1 have been investigated in the temperature range 1.9-295 K. They are typical of an overall antiferromagnetic coupling with a maximum of the magnetic susceptibility at 22.0 K. The analysis of the susceptibility data of 1 through an effective spin Hamiltonian allowed a satisfactory simulation in the temperature range 10-295 K with the best-fit parameters λ = -110 cm(-1), α = 1.1, |Δ| = 400 cm(-1), J(ox) = -11.1 cm(-1) and J(bpm) = -5.0 cm(-1). The values of the antiferromagnetic coupling through bpm and ox in 1 have also been supported by electronic structure calculations based on Density Functional Theory (DFT) and they compare well with those reported in the literature for bpm-bridged dicobalt(II) complexes and oxalate-bridged cobalt(II) chains.

  2. Measured maximal heart rates compared to commonly used age-based prediction equations in the Heritage Family Study.

    PubMed

    Sarzynski, M A; Rankinen, T; Earnest, C P; Leon, A S; Rao, D C; Skinner, J S; Bouchard, C

    2013-01-01

    The purpose of this study was to examine how well two commonly used age-based prediction equations for maximal heart rate (HRmax ) estimate the actual HRmax measured in Black and White adults from the HERITAGE Family Study. A total of 762 sedentary subjects (39% Black, 57% Females) from HERITAGE were included. HRmax was measured during maximal exercise tests using cycle ergometers. Age-based HRmax was predicted using the Fox (220-age) and Tanaka (208 - 0.7 × age) formulas. The standard error of estimate (SEE) of predicted HRmax was 12.4 and 11.4 bpm for the Fox and Tanaka formulas, respectively, indicating a wide-spread of measured-HRmax values are compared to their age-predicted values. The SEE (shown as Fox/Tanaka) was higher in Blacks (14.4/13.1 bpm) and Males (12.6/11.7 bpm) compared to Whites (11.0/10.2 bpm) and Females (12.3/11.2 bpm) for both formulas. The SEE was higher in subjects above the BMI median (12.8/11.9 bpm) and below the fitness median (13.4/12.4 bpm) when compared to those below the BMI median (12.2/11.0 bpm) and above the fitness median (11.4/10.3) for both formulas. Our findings show that based on the SEE, the prevailing age-based estimated HRmax equations do not precisely predict an individual's measured-HRmax . Copyright © 2013 Wiley Periodicals, Inc.

  3. A Method for Transforming Existing Web Service Descriptions into an Enhanced Semantic Web Service Framework

    NASA Astrophysics Data System (ADS)

    Du, Xiaofeng; Song, William; Munro, Malcolm

    Web Services as a new distributed system technology has been widely adopted by industries in the areas, such as enterprise application integration (EAI), business process management (BPM), and virtual organisation (VO). However, lack of semantics in the current Web Service standards has been a major barrier in service discovery and composition. In this chapter, we propose an enhanced context-based semantic service description framework (CbSSDF+) that tackles the problem and improves the flexibility of service discovery and the correctness of generated composite services. We also provide an agile transformation method to demonstrate how the various formats of Web Service descriptions on the Web can be managed and renovated step by step into CbSSDF+ based service description without large amount of engineering work. At the end of the chapter, we evaluate the applicability of the transformation method and the effectiveness of CbSSDF+ through a series of experiments.

  4. Small Aperture BPM to Quadrupole Assembly Tolerance Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, K. W.

    2010-12-07

    The LCLS injector and linac systems utilize a series of quadrupole magnets with a beam position monitor (BPM) captured in the magnet pole tips. The BPM measures the electron beam position by comparing the electrical signal from 4 electrodes and interpolating beam position from these signals. The manufacturing tolerances of the magnet and BPM are critical in determining the mechanical precision of the electrodes relative to the nominal electron beam Z-axis. This study evaluates the statistical uncertainty of the electrodes center axis relative to the nominal electron beam axis.

  5. Cavity BPM with Dipole-Mode-Selective Coupler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zenghai; Johnson, Ronald; Smith, Stephen R.

    2006-06-21

    In this paper, we present a novel position sensitive signal pickup scheme for a cavity BPM. The scheme utilizes the H-plane of the waveguide to couple magnetically to the side of the cavity, which results in a selective coupling to the dipole mode and a total rejection of the monopole mode. This scheme greatly simplifies the BPM geometry and relaxes machining tolerances. We will present detailed numerical studies on such a cavity BPM, analyze its resolution limit and tolerance requirements for a nanometer resolution. Finally present the measurement results of a X-band prototype.

  6. RanBPM: a potential therapeutic target for modulating diverse physiological disorders.

    PubMed

    Das, Soumyadip; Suresh, Bharathi; Kim, Hyongbum Henry; Ramakrishna, Suresh

    2017-12-01

    The Ran-binding protein microtubule-organizing center (RanBPM) is a highly conserved nucleocytoplasmic protein involved in a variety of intracellular signaling pathways that control diverse cellular functions. RanBPM interacts with proteins that are linked to various diseases, including Alzheimer's disease (AD), schizophrenia (SCZ), and cancer. In this article, we define the characteristics of the scaffolding protein RanBPM and focus on its interaction partners in diverse physiological disorders, such as neurological diseases, fertility disorders, and cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Overview of recent trends and developments for BPM systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendt, M.; /Fermilab

    2011-08-01

    Beam position monitoring (BPM) systems are the workhorse of beam diagnostics for almost any kind of charged particle accelerator: linear, circular or transport-lines, operating with leptons, hadrons or heavy ions. BPMs are essential for beam commissioning, accelerator fault analysis and trouble shooting, machine optics, as well as lattice measurements, and finally, for accelerator optimization, in order to achieve the ultimate beam quality. This presentation summarizes the efforts of the beam instrumentation community on recent developments and advances on BPM technologies, i.e. BPM pickup monitors and front-end electronics (analog and digital). Principles, examples, and state-of-the-art status on various BPM techniques, servingmore » hadron and heavy ion machines, sync light synchrotron's, as well as electron linacs for FEL or HEP applications are outlined.« less

  8. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells

    PubMed Central

    Singh, Satyendra; Klarmann, Kimberly D.; Coppola, Vincenzo; Keller, Jonathan R.; Tessarollo, Lino

    2016-01-01

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies. PMID:27835883

  9. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells.

    PubMed

    Puverel, Sandrine; Kiris, Erkan; Singh, Satyendra; Klarmann, Kimberly D; Coppola, Vincenzo; Keller, Jonathan R; Tessarollo, Lino

    2016-12-20

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies.

  10. [Relationship between baseline heart rate and all-cause death in general population].

    PubMed

    Chen, Ji; Chen, Shuo-hua; Liu, Xing; Zhang, Cai-feng; Yao, Tao; Yang, Hui; Wang, Jian-li; Wu, Shou-ling

    2013-06-01

    To investigate the relationship between baseline heart rate(HR) and all-cause death(ACD)in general population. 93 716 workers with heart rate between 40 bpm/min-120 bpm/min and without histories of stroke were selected from the '2006-2007 health examination records' in Kailuan and completed the electrocardiogram exam. Related information were also gathered. These subjects were followed up from July 2006 to December 2010, with the mean time of follow-up as 47.5±4.3 months. During the follow-up period, the occurrence of all-cause death was observed every half a year. (1)The lowest cumulative mortality rate was 1.61% in the group with 60-69 bpm/min. The lowest cumulative mortality rate was 1.78% in the group of 60-69 bpm/min in men. There was no death events observed in women with less than 50 bpm/min and the lowest cumulative mortality rate was 0.60% in the group of 80-89 bpm/min in women. (2)Data from Cox proportional hazard regression analysis showed that the RR(95%CI)of cumulative mortality rates in general population were 1.187 (1.039-1.336), 1.392(1.185-1.636), 1.733(1.404-2.139)and 2.716 (2.171-3.398)in the groups of 70-79, 80-89, 90-99 and ≥100 bpm/min, respectively. The RRs (95% CI) of cumulative mortality in men were 1.227(1.067-1.410), 1.481(1.254-1.750), 1.754 (1.406-2.188)and 2.831 (2.245-3.571) respectively. In women, when comparing with the group of 80-89 bpm/min, the RRs (95%CI)of all-cause death were 0.671(0.568-0.793), 0.825(0.703-0.970) and 1.925 (1.512-2.453)respectively in the groups of 60-69, 70-79 and ≥100 bpm/min. When HR exceeding ≥70 bpm/min, the increase of HR would also increase the rate of ACD. Results of our study also showed a J-shaped curve relation between HR and mortality.

  11. Influences on Satisfaction with Reconstructed Breasts and Intimacy in Younger Women Following Bilateral Prophylactic Mastectomy: a Qualitative Analysis.

    PubMed

    Glassey, Rachael; O'Connor, Moira; Ives, Angela; Saunders, Christobel; Hardcastle, Sarah J

    2018-04-30

    The aim of this study was to explore the influences on satisfaction with reconstructed breasts and intimacy following bilateral prophylactic mastectomy (BPM) in younger women (< 35) with a strong family history of breast cancer. Twenty-six women who had undergone BPM between 1 and6 years ago were recruited from New Zealand and Australia through a genetics clinic, registry, research cohort, and online (M age  = 31). Twenty-three were BRCA mutation carriers. Qualitative interviews guided by interpretative phenomenological analysis were conducted. Four themes were identified: satisfaction with breasts before surgery, outcome expectations, type of mastectomy, and open communication. Women who liked their breasts pre-BPM appeared less satisfied with their reconstructed breasts post-surgery, and women who disliked their breasts before BPM were more satisfied with their reconstructed breasts. Women with unrealistic expectations concerning the look and feel of reconstructed breasts were often unhappy with their reconstructed breasts and felt they did not meet their expectations. Unrealistic photos of breast reconstruction and satisfactory communication of realistic outcome expectations by surgeons or psychologists also appeared to influence satisfaction. Communication with partners prior to BPM appeared to improve satisfaction with intimacy post-BPM. The findings suggest that satisfaction with reconstructed breasts for younger women post-BPM appeared to be influenced by realistic outcome expectations and communication with others concerning reconstructed breast appearance and intimacy post-BPM. Implications for practice include discussion of realistic reconstructed breast appearance, referral to a psychologist to discuss sensitive issues, and accurate communication of surgical risks and consequences.

  12. A diminished aortic-cardiac reflex during hypotension in aerobically fit young men

    NASA Technical Reports Server (NTRS)

    Shi, X.; Crandall, C. G.; Potts, J. T.; Williamson, J. W.; Foresman, B. H.; Raven, P. B.

    1993-01-01

    We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

  13. Resting heart rate associates with one-year risk of major adverse cardiovascular events in patients with acute coronary syndrome after percutaneous coronary intervention.

    PubMed

    Wang, Shao-Li; Wang, Cheng-Long; Wang, Pei-Li; Xu, Hao; Du, Jian-Peng; Zhang, Da-Wu; Gao, Zhu-Ye; Zhang, Lei; Fu, Chang-Geng; Chen, Ke-Ji; Shi, Da-Zhuo

    2016-03-01

    The study was to access the association between resting heart rate (RHR) and one-year risk of major adverse cardiovascular events (MACE) in acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). Patients with ACS after PCI (n = 808) were prospectively followed-up for MACE. RHR was obtained from electrocardiogram. MACE was defined as a composite of cardiac death, nonfatal recurrent myocardial infarction, ischemic-driven revascularization, and ischemic stroke. The association between RHR and one-year risk of MACE was assessed using Cox proportional hazards regression model. Compared with patients with RHR >76 bpm, the adjusted hazard ratio (AHR) was 0.51 (95% confidence intervals [CI]: 0.23-1.14; P = 0.100) for patients with RHR < 61 bpm, and 0.44 (95%CI: 0.23-0.85; P = 0.014) for those with RHR 61-76 bpm. For patients with RHR ≥ 61 bpm, an increase of 10 bpm in RHR was associated with an increase by 38.0% in the risk of MACE (AHR: 1.38; 95% CI: 1.04-1.83; P = 0.026). ACS patients after PCI with RHR >76 bpm were at higher risk of MACE during one-year follow-up compared with patients with RHR 61-76 bpm. An elevated RHR ≥ 61 bpm was associated with increased risk of one-year MACE in ACS patients. © 2015 by the Society for Experimental Biology and Medicine.

  14. Resting heart rate associates with one-year risk of major adverse cardiovascular events in patients with acute coronary syndrome after percutaneous coronary intervention

    PubMed Central

    Wang, Shao-Li; Wang, Cheng-Long; Wang, Pei-Li; Xu, Hao; Du, Jian-Peng; Zhang, Da-Wu; Gao, Zhu-Ye; Zhang, Lei; Fu, Chang-Geng; Chen, Ke-Ji

    2015-01-01

    The study was to access the association between resting heart rate (RHR) and one-year risk of major adverse cardiovascular events (MACE) in acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). Patients with ACS after PCI (n = 808) were prospectively followed-up for MACE. RHR was obtained from electrocardiogram. MACE was defined as a composite of cardiac death, nonfatal recurrent myocardial infarction, ischemic-driven revascularization, and ischemic stroke. The association between RHR and one-year risk of MACE was assessed using Cox proportional hazards regression model. Compared with patients with RHR >76 bpm, the adjusted hazard ratio (AHR) was 0.51 (95% confidence intervals [CI]: 0.23–1.14; P = 0.100) for patients with RHR < 61 bpm, and 0.44 (95%CI: 0.23–0.85; P = 0.014) for those with RHR 61–76 bpm. For patients with RHR ≥ 61 bpm, an increase of 10 bpm in RHR was associated with an increase by 38.0% in the risk of MACE (AHR: 1.38; 95% CI: 1.04–1.83; P = 0.026). ACS patients after PCI with RHR >76 bpm were at higher risk of MACE during one-year follow-up compared with patients with RHR 61–76 bpm. An elevated RHR ≥ 61 bpm was associated with increased risk of one-year MACE in ACS patients. PMID:26585407

  15. Optically Remote Noncontact Heart Rates Sensing Technique

    NASA Astrophysics Data System (ADS)

    Thongkongoum, W.; Boonduang, S.; Limsuwan, P.

    2017-09-01

    Heart rate monitoring via optically remote noncontact technique was reported in this research. A green laser (5 mW, 532±10 nm) was projected onto the left carotid artery. The reflected laser light on the screen carried the deviation of the interference patterns. The interference patterns were recorded by the digital camera. The recorded videos of the interference patterns were frame by frame analysed by 2 standard digital image processing (DIP) techniques, block matching (BM) and optical flow (OF) techniques. The region of interest (ROI) pixels within the interference patterns were analysed for periodically changes of the interference patterns due to the heart pumping action. Both results of BM and OF techniques were compared with the reference medical heart rate monitoring device by which a contact measurement using pulse transit technique. The results obtained from BM technique was 74.67 bpm (beats per minute) and OF technique was 75.95 bpm. Those results when compared with the reference value of 75.43±1 bpm, the errors were found to be 1.01% and 0.69%, respectively.

  16. Identification of Arabidopsis MYB56 as a novel substrate for CRL3(BPM) E3 ligases.

    PubMed

    Chen, Liyuan; Bernhardt, Anne; Lee, JooHyun; Hellmann, Hanjo

    2015-02-01

    Controlled stability of proteins is a highly efficient mechanism to direct diverse processes in living cells. A key regulatory system for protein stability is given by the ubiquitin proteasome pathway, which uses E3 ligases to mark specific proteins for degradation. In this work, MYB56 is identified as a novel target of a CULLIN3 (CUL3)-based E3 ligase. Its stability depends on the presence of MATH-BTB/POZ (BPM) proteins, which function as substrate adaptors to the E3 ligase. Genetic studies have indicated that MYB56 is a negative regulator of flowering, while BPMs positively affect this developmental program. The interaction between BPMs and MYB56 occurs at the promoter of FLOWERING LOCUS T (FT), a key regulator in initiating flowering in Arabidopsis, and results in instability of MYB56. Overall the work establishes MYB transcription factors as substrates of BPM proteins, and provides novel information on components that participate in controlling flowering time in plants. Copyright © 2015 The Author. Published by Elsevier Inc. All rights reserved.

  17. Syntheses, crystal structures, and magnetic properties of the oxalato-bridged mixed-valence complexes (FeII(bpm)3]2[FeIII2(ox)5].8H2O and FeII(bpm)3Na(H2O)2Fe(ox)(3).4H2O (bpm = 2,2'-bipyrimidine).

    PubMed

    Armentano, D; De Munno, G; Faus, J; Lloret, F; Julve, M

    2001-02-12

    The preparation and crystal structures of two oxalato-bridged FeII-FeIII mixed-valence compounds, [FeII(bpm)3]2[FeIII2(ox)5].8H2O (1) and FeII(bpm)3Na(H2O)2FeIII(ox)(3).4H2O (2) (bpm = 2,2'-bipyrimidine; ox = oxalate dianion) are reported here. Complex 1 crystallizes in the triclinic system, space group P1, with a = 10.998(2) A, b = 13.073(3) A, c = 13.308(3) A, alpha = 101.95(2) degrees, beta = 109.20(2) degrees, gamma = 99.89(2) degrees, and Z = 1. Complex 2 crystallizes in the monoclinic system, space group P2(1)/c, with a = 12.609(2) A, b = 19.670(5) A, c = 15.843(3) A, beta = 99.46(1) degrees, and Z = 4. The structure of complex 1 consists of centrosymmetric oxalato-bridged dinuclear high-spin iron(III) [Fe2(ox)5]2- anions, tris-chelated low-spin iron(II) [Fe(bpm)3]2+ cations, and lattice water molecules. The iron atoms are hexacoordinated: six oxygen atoms (iron(III)) from two bidentate and one bisbidentate oxalato ligands and six nitrogen atoms (iron(II)) from three bidentate bpm groups. The Fe(III)-O(ox) and Fe(II)-N(bpm) bond distances vary in the ranges 1.967(3)-2.099(3) and 1.967(4)-1.995(3) A, respectively. The iron(III)-iron(III) separation across the bridging oxalato is 5.449(2) A, whereas the shortest intermolecular iron(III)-iron(II) distance is 6.841(2) A. The structure of complex 2 consists of neutral heterotrinuclear Fe(bpm)2Na(H2O)2Fe(ox)3 units and water molecules of crystallization. The tris-chelated low-spin iron(II) ([Fe(bpm)3]2+) and high-spin iron(III) ([Fe(ox)3]3-) entities act as bidentate ligands (through two bpm-nitrogen and two oxalato-oxygen atoms, respectively) toward the univalent sodium cation, yielding the trinuclear (bpm)2Fe(II)-bpm-Na(I)-ox-Fe(III)(ox)2 complex. Two cis-coordinated water molecules complete the distorted octahedral surrounding of the sodium atom. The ranges of the Fe(II)-N(bpm) and Fe(III)-O(ox) bond distances [1.968(6)-1.993(5) and 1.992(6)-2.024(6) A, respectively] compare well with those observed in 1. The Na-N(bpm) bond lengths (2.548(7) and 2.677(7) A) are longer than those of Na-O(ox) (2.514(7) and 2.380(7) A) and Na-O(water) (2.334(15) and 2.356(12) A). The intramolecular Fe(II)...Fe(III) separation is 6.763(2) A, whereas the shortest intermolecular Fe(II)...Fe(II) and Fe(III)...Fe(III) distances are 8.152(2) and 8.992(2) A, respectively. Magnetic susceptibility measurements in the temperature range 2.0-290 K for 1 reveal that the high-spin iron(III) ions are antiferromagnetically coupled (J = -6.6 cm-1, the Hamiltonian being defined as H = -JS1.S2). The magnitude of the antiferromagnetic coupling through the bridging oxalato in the magneto-structurally characterized family of formula [M2(ox)5](2m-10)+ (M = Fe(III) (1), Cr(III), and Ni(II)) is analyzed and discussed by means of a simple orbital model.

  18. Maximal heart rate in soccer players: measured versus age-predicted.

    PubMed

    Nikolaidis, Pantelis T

    2015-01-01

    Although maximal heart rate (HR max) is widely used to assess exercise intensity in sport training, and particularly in soccer, there are limited data with regards to the use of age-based prediction equations of HR max in soccer players. The aim of this study was to compare the measured-HR max with two prediction equations (Fox-HR max = 220 - age and Tanaka-HR max = 208 - 0.7 × age) in soccer players. Adolescent (n = 162, 15.8 ± 1.5 years) and adult players (n = 158, 23.4 ± 4.6 years), all members of competitive clubs, voluntarily performed a graded exercise field test (Conconi protocol) to assess HR max . The measured-HR max (197.6 ± 9.4 bpm in total, 200.2 ± 7.9 bpm in adolescent players, and 195.0 ± 10.0 bpm in adult players) was explained by the formula HR max = 212.3 - 0.75 × age (r = -0.41, standard error of the estimate = 8.6). In the total sample, Fox-HR max overestimated measured-HR max [mean difference (95% confidence intervals) = 2.8 bpm (1.6; 3.9)], while Tanaka-HR max underestimated HR max [-3.3 bpm (-4.5; -2.2)]. In adolescents, Fox-HR max overestimated measured-HR max [4.0 bpm (2.5; 5.5)] and Tanaka-HR max underestimated HR max [- 3.2 bpm (-4.7; -1.8)]. In adults, Tanaka-HR max underestimated HR max [-5.0 bpm (-5.3; -4.7)], while there was not any difference between Fox-HR max and measured-HR max [1.6 bpm (-3.4; 0.2)]. The results of this study failed to validate two widely used prediction equations in a large sample of soccer players, indicating the need for a sport-specific equation. On the other hand, the new equation that we presented should be investigated further by future studies before being adopted by coaches and fitness trainers.

  19. Heart rate as an independent risk factor in patients with multiple organ dysfunction: a prospective, observational study.

    PubMed

    Hoke, Robert S; Müller-Werdan, Ursula; Lautenschläger, Christine; Werdan, Karl; Ebelt, Henning

    2012-02-01

    To study the association between baseline heart rate and outcome in patients with multiple organ dysfunction (MODS) as well as the course of heart rate over the first 4 days during MODS. Prospective observational study in 89 patients with MODS, defined as an APACHE-II score ≥20. Baseline heart rate (HR(0)) was determined over a 60-minute period at the time of MODS diagnosis. 28-day all-cause mortality was the primary endpoint of the study, a fall of the APACHE-II score by 4 points or more from day 0 to day 4 constituted the secondary endpoint. Hazard ratios for heart rate of 90 beats per minute (bpm) or greater relative to less than 90 bpm were calculated using Cox proportional hazards model and adjusted for confounding variables. Median baseline heart rate was 83 bpm in survivors and 92 bpm in non-survivors (p = 0.048). 28-day mortality was 32 and 61% in patients with HR(0) < 90 bpm and HR(0) ≥ 90 bpm, respectively. The adjusted hazard ratio for 28-day mortality was 2.30 (95% confidence interval 1.21-4.36, p = 0.001) for HR(0) ≥ 90 bpm relative to HR(0) < 90 bpm. No correlation was found between baseline heart rate and the secondary endpoint. From day 0 to day 4, heart rate remained elevated in all patients, as well as in survivors and non-survivors. A heart rate ≥90 bpm at the time of MODS diagnosis is an independent risk factor for increased 28-day mortality. As in patients with cardiovascular conditions such as coronary heart disease or chronic heart failure, heart rate might constitute a target for heart rate-lowering therapy in the narrow initial treatment window of MODS.

  20. Successful implantation of an abdominal aortic blood pressure transducer and radio-telemetry transmitter in guinea pigs - Anaesthesia, analgesic management and surgical methods, and their influence on hemodynamic parameters and body temperature.

    PubMed

    Schmitz, Sabrina; Henke, Julia; Tacke, Sabine; Guth, Brian

    2016-01-01

    Guinea pigs (GPs) are a valuable cardiovascular pharmacology model. Implantation of a radio-telemetry system into GPs is, however, challenging and has been associated with a high failure rate in the past. We provide information on a novel procedure for implanting telemetry devices into GPs and we have measured the hemodynamics (arterial blood pressure, BP and heart rate, HR) and core body temperature (BT) in the 24h after surgery. Male Hartley GPs (Crl:HA, 350-400g, 6.5weeks, n=16) were implanted with a radio transmitter abdominally and were then monitored continuously (HR, BP and BT) for 24h after surgery. 13 of 16 GPs (81%) survived the surgery. Surgery duration was 94min (min) (range: 76-112min) and anaesthesia duration was 131min (range: 107-158min). GPs lost body weight until 2days after surgery and then regained weight. Mean arterial BP increased from 33.7mmHg directly after surgery to 59.1mmHg after 24h. HR increased from 206bpm directly after surgery to 286bpm at 8h and fell to 251bpm at 24h after implantation. BT was 36°C directly after surgery, fell to 35.4°C until regaining of the righting reflex and then stabilized at 38.5°C after 24h. A high survival rate in telemetered GPs is possible. We achieved this through a procedure with minimal stress through habituation and planning, continuous warming during anaesthesia, an optimal anaesthetic and analgesic management, efficient surgical techniques and vitamin C supplementation. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  1. A beating heart cell model to predict cardiotoxicity: effects of the dietary supplement ingredients higenamine, phenylethylamine, ephedrine and caffeine.

    PubMed

    Calvert, Richard; Vohra, Sanah; Ferguson, Martine; Wiesenfeld, Paddy

    2015-04-01

    Some dietary supplements may contain cardiac stimulants and potential cardiotoxins. In vitro studies may identify ingredients of concern. A beating human cardiomyocyte cell line was used to evaluate cellular effects following phenylethylamine (PEA), higenamine, ephedrine or caffeine treatment. PEA and higenamine exposure levels simulated published blood levels in humans or animals after intravenous administration. Ephedrine and caffeine levels approximated published blood levels following human oral intake. At low or midrange levels, each chemical was examined plus or minus 50 µM caffeine, simulating human blood levels reported after consumption of caffeine-enriched dietary supplements. To measure beats per minute (BPM), peak width, etc., rhythmic rise and fall in intracellular calcium levels following 30 min of treatment was examined. Higenamine 31.3 ng/ml or 313 ng/ml significantly increased BPM in an escalating manner. PEA increased BPM at 0.8 and 8 µg/ml, while 80 µg/ml PEA reduced BPM and widened peaks. Ephedrine produced a significant BPM dose response from 0.5 to 5.0 µM. Caffeine increased BPM only at a toxic level of 250 µM. Adding caffeine to PEA or higenamine but not ephedrine further increased BPM. These in vitro results suggest that additional testing may be warranted in vivo to further evaluate these effects. Published by Elsevier Ltd.

  2. A Big Data-driven Model for the Optimization of Healthcare Processes.

    PubMed

    Koufi, Vassiliki; Malamateniou, Flora; Vassilacopoulos, George

    2015-01-01

    Healthcare organizations increasingly navigate a highly volatile, complex environment in which technological advancements and new healthcare delivery business models are the only constants. In their effort to out-perform in this environment, healthcare organizations need to be agile enough in order to become responsive to these increasingly changing conditions. To act with agility, healthcare organizations need to discover new ways to optimize their operations. To this end, they focus on healthcare processes that guide healthcare delivery and on the technologies that support them. Business process management (BPM) and Service-Oriented Architecture (SOA) can provide a flexible, dynamic, cloud-ready infrastructure where business process analytics can be utilized to extract useful insights from mountains of raw data, and make them work in ways beyond the abilities of human brains, or IT systems from just a year ago. This paper presents a framework which provides healthcare professionals gain better insight within and across your business processes. In particular, it performs real-time analysis on process-related data in order reveal areas of potential process improvement.

  3. Design of the detector to observe the energetic charged particles: a part of the solar X-ray spectrophotometer ChemiX onboard Interhelio-Probe mission

    NASA Astrophysics Data System (ADS)

    Dudnik, Oleksiy; Sylwester, Janusz; Kowalinski, Miroslaw; Bakala, Jaroslaw; Siarkowski, Marek; Evgen Kurbatov, mgr..

    2016-07-01

    Cosmic particle radiation may damages payload's electronics, optics, and sensors during of long-term scientific space mission especially the interplanetary ones. That is why it's extremely important to prevent failures of digital electronics, CCDs, semiconductor detectors at the times of passing through regions of enhanced charged particle fluxes. Well developed models of the Earth's radiation belts allow to predict and to protect sensitive equipment against disastrous influence of radiation due to energetic particle contained in the Van Allen belts. In the contrary interplanetary probes flying far away from our planet undergoes passages through clouds of plasma and solar cosmic rays not predictable by present models. Especially these concerns missions planned for non-ecliptic orbits. The practical approach to protect sensitive modules may be to measure the in situ particle fluxes with high time resolution and generation of alarm flags, which will switch off sensitive units of particular scientific equipment. The ChemiX (Chemical composition in X-rays) instrument is being developed by the Solar Physics Division of Polish Space Research Centre for the Interhelio-Probe interplanetary mission. Charged particle bursts can badly affect the regular measurements of X-ray spectra of solar origin. In order to detect presence of these enhanced particle fluxes the Background Particle Monitor (BPM) was developed constituting now a vital part of ChemiX. The BPM measurements of particle fluxes will assist to determine level of X-ray spectra contamination. Simultaneously BPM will measure the energy spectra of ambient particles. We present overall structure, design, technical and a scientific characteristic of BPM, particle sorts, and energy ranges to be registered. We describe nearly autonomous modular structure of BPM consisting of detector head, analogue and digital electronics modules, and of module of secondary power supply [1-3]. Detector head consists of three-layer detector stack: first two layers consist of silicon detectors; the third one is based on the p-terphenyl scintillation detector coupled with pixelated silicon photomultiplier. Coincidence logic allows collecting systematic data on particle variety and their energy with 1 and/or 10 s time resolutions. Digital processing unit is constructed based on FPGA Actel ProAsic M1A3PE1500, and contains each event processing logic, forms telemetry data and housekeeping frames, communicates with ChemiX digital processing unit and executes received telecommands. In order to increase the reliability and time resource of the BPM its digital processing unit and secondary power supply unit has backup sets. Switching between backup sets is commanded by externally orders. The BPM is capable to sort out in situ abundances of individual particle constituents from electrons up to oxygen nuclei. 1. O.V.Dudnik, E.V.Kurbatov, V.O.Tarasov, L.A.Andryushenko, I.L.Zajtsevsky, J.Sylwester, J.Bąkala, M.Kowaliński. Background particle detector for the solar X-ray photometer ChemiX of space mission "Interhelioprobe": an adjustment of breadboard model modules (in Russian) / ISSN 1561-8889: Kosmichna Nauka I Tekhnologiya, 2015, Vol.21, No.2, P.3-14. 2. O.V.Dudnik, E.V.Kurbatov, J.Sylwester, M.Siarkowski, P.Podgórski, M.Kowaliński. Background Particle Monitor - a part of the solar X-ray spectrophotometer ChemiX: principles of the operation and construction / in: Abstracts of 15th Ukrainian conference on space research, Odesa, Ukraine, August 24-28, 2015, P.80, doi:10.13140/RG.2.1.2284.2649. 3. O.V.Dudnik, E.V.Kurbatov, M.Kowaliński, M.Siarkowski, P.Podgórski, J.Sylwester. Operational features of Background Particle Monitor, a vital part of the solar X-ray spectrophotometer ChemiX / in: Abstract book of the Conference "Progress on EUV&X-ray spectroscopy and imaging II", Wroclaw, Poland, November 17 19, 2015, P.9, doi:10.13140/RG.2.1.1184.3604.

  4. Temporal dynamics and the identification of musical key.

    PubMed

    Farbood, Morwaread Mary; Marcus, Gary; Poeppel, David

    2013-08-01

    A central process in music cognition involves the identification of key; however, little is known about how listeners accomplish this task in real time. This study derives from work that suggests overlap between the neural and cognitive resources underlying the analyses of both music and speech and is the first, to our knowledge, to explore the timescales at which the brain infers musical key. We investigated the temporal psychophysics of key-finding over a wide range of tempi using melodic sequences with strong structural cues, where statistical information about overall key profile was ambiguous. Listeners were able to provide robust judgments within specific limits, at rates as high as 400 beats per minute (bpm; ∼7 Hz) and as low as 30 bpm (0.5 Hz), but not outside those bounds. These boundaries on reliable performance show that the process of key-finding is restricted to timescales that are closely aligned with beat induction and speech processing. 2013 APA, all rights reserved

  5. 75 FR 57410 - Address Correction Notices for Letters and Flats Qualifying for Full-Service Intelligent Mail and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-21

    ... First-Class Mail[supreg], Standard Mail[supreg], and Bound Printed Matter (BPM) pieces that are eligible...-Class Mail, Standard Mail, or BPM prices. This change will coincide with the current Move Update... First-Class Mail, Standard Mail, and BPM full-service pieces. Prices for notices provided after this...

  6. Fetal QRS detection and heart rate estimation: a wavelet-based approach.

    PubMed

    Almeida, Rute; Gonçalves, Hernâni; Bernardes, João; Rocha, Ana Paula

    2014-08-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR.

  7. Factors associated with sinus bradycardia during crizotinib treatment: a retrospective analysis of two large-scale multinational trials (PROFILE 1005 and 1007).

    PubMed

    Ou, Sai-Hong Ignatius; Tang, Yiyun; Polli, Anna; Wilner, Keith D; Schnell, Patrick

    2016-04-01

    Decreases in heart rate (HR) have been described in patients receiving crizotinib. We performed a large retrospective analysis of HR changes during crizotinib therapy. HRs from vital-sign data for patients with anaplastic lymphoma kinase (ALK)-positive nonsmall cell lung cancer enrolled in PROFILE 1005 and the crizotinib arm of PROFILE 1007 were analyzed. Sinus bradycardia (SB) was defined as HR <60 beats per minute (bpm). Magnitude and timing of HR changes were assessed. Potential risk factors for SB were investigated by logistic regression analysis. Progression-free survival (PFS) was evaluated according to HR decrease by <20 versus ≥ 20 bpm within the first 50 days of starting treatment. For the 1053 patients analyzed, the mean maximum postbaseline HR decrease was 25 bpm (standard deviation 15.8). Overall, 441 patients (41.9%) had at least one episode of postbaseline SB. The mean precrizotinib treatment HR was significantly lower among patients with versus without postbaseline SB (82.2 bpm vs. 92.6 bpm). The likelihood of experiencing SB was statistically significantly higher among patients with a precrizotinib treatment HR <70 bpm. PFS was comparable among patients with or without HR decrease of ≥ 20 bpm within the first 50 days of starting crizotinib. Decrease in HR is very common among patients on crizotinib. The likelihood of experiencing SB was statistically significantly higher among patients with a precrizotinib treatment HR <70 bpm. This is the first large-scale report investigating the association between treatment with a tyrosine kinase inhibitor and the development of bradycardia. HRs should be closely monitored during crizotinib treatment. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  8. Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    PubMed

    Wright, J M; Mattu, G S; Perry, T L; Gelferc, M E; Strange, K D; Zorn, A; Chen, Y

    2001-06-01

    To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. Raw pulse wave and cuff pressure data were stored electronically using embedded software in the BPM-100(Beta), during the validation trial. The 391 sets of measurements were separated objectively into two subsets. A subset of 136 measurements was used to develop a new algorithm to enhance the accuracy of the device when reading higher systolic pressures. The larger subset of 255 measurements (three readings for 85 subjects) was used as test data to validate the accuracy of the new algorithm. Differences between the new algorithm BPM-100 and the reference (mean of two observers) were determined and expressed as the mean difference +/- SD, plus the percentage of measurements within 5, 10, and 15 mmHg. The mean difference between the BPM-100 and reference systolic BP was -0.16 +/- 5.13 mmHg, with 73.7% < or = 5 mmHg, 94.9% < or = 10 mmHg and 98.8% < or = 15 mmHg. The mean difference between the BPM-100 and reference diastolic BP was -1.41 +/- 4.67 mmHg, with 78.4% < or = 5 mmHg, 92.5% < or = 10 mmHg, and 99.2% < or = 15 mmHg. These data improve upon that of the BPM-100(Beta) and pass the AAMI standard, and 'A' grade BHS protocol. This study illustrates a new method for developing and testing a change in an algorithm for an oscillometric BP monitor utilizing collected and stored electronic data and demonstrates that the new algorithm meets the AAMI standard and BHS protocol.

  9. Comparison of the oscillometric blood pressure monitor (BPM-100(Beta) ) with the auscultatory mercury sphygmomanometer.

    PubMed

    Mattu, G S; Perry, T L; Wright, J M

    2001-06-01

    To compare directly the accuracy of the BPM-100(Beta) monitor (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry. The BPM-100(Beta) was connected in parallel via a T-tube to a mercury sphygmomanometer. The BPM-100(Beta) and two trained observers (blinded from each other and from the BPM-100(Beta)) measured the sitting blood pressure simultaneously. Means, standard deviations and ranges were calculated for all the demographic data: age, arm size, heart rate and blood pressure. The agreement between the BPM-100(Beta) and the mean of two observers (the reference) was determined and expressed as the mean +/- SD, as well as the percentage of differences falling within 5, 10 and 15 mmHg. Of the 92 subjects recruited, 85 (92.4%) met the inclusion criteria, and 391 sets of sitting blood pressure and heart rate measurements were available for analysis. The mean difference between the BPM-100(Beta) monitor and the reference was -0.62 +/- 6.96 mmHg for systolic blood pressure, -1.48 +/- 4.80 mmHg for diastolic blood pressure and 0.14 +/- 1.86 beats/min for heart rate. The only limitation of the device was its tendency to underestimate higher systolic blood pressures. This problem has been addressed by a minor change in the algorithm (see the companion publication, Blood Press Monit, 6, 161-165, 2001). The BPM-100(Beta) is an accurate blood pressure monitor for the office setting, meeting all requirements of the Association for the Advancement of Medical Instrumentation and achieving an 'A' grade according to the British Hypertension Society protocol.

  10. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.

    PubMed

    Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh

    2017-11-01

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.

  11. Association of Fetal Heart Rate Baseline Change and Neonatal Outcomes.

    PubMed

    Yang, Michael; Stout, Molly J; López, Julia D; Colvin, Ryan; Macones, George A; Cahill, Alison G

    2017-07-01

    Objective  The objective of this study was to describe the incidence of baseline change within normal range during labor and its prediction of neonatal outcomes. Materials and Methods  This was a prospective cohort of singleton, nonanomalous, term neonates with continuous electronic fetal monitoring and normal baseline fetal heart rate throughout the last 2 hours of labor. We determined baseline in 10-minute segments using Eunice Kennedy Shriver National Institute of Child Health and Human Development criteria. We evaluated baseline changes of ≥ 20 and ≥ 30 bpm for association with acidemia (umbilical cord arterial pH ≤ 7.10) and neonatal intensive care unit (NICU) admission. Finally, we performed a sensitivity analysis of normal neonates, excluding those with acidemia, NICU admission, or 5-minute Apgar < 4. Results  Among all neonates ( n  = 3,021), 1,267 (41.9%) had change ≥ 20 bpm; 272 (9.0%) had ≥ 30 bpm. Among normal neonates ( n  = 2,939), 1,221 (41.5%) had change ≥20 bpm. Acidemia was not associated with baseline change of any direction or magnitude. NICU admission was associated with decrease ≥ 20 bpm (adjusted odds ratio [aOR]: 2.93; 95% confidence interval [CI]: 1.19 - 7.21) or any direction ≥ 20 bpm (aOR: 4.06; 95% CI: 1.46-11.29). For decrease ≥ 20 bpm, sensitivity and specificity were 40.0 and 81.7%; for any direction ≥ 20 bpm, 75.0 and 58.3%. Conclusion  Changes of normal baseline are common in term labor and poorly predict morbidity, regardless of direction or magnitude. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio

    2015-09-01

    Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    NASA Astrophysics Data System (ADS)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  14. Numerical analysis of the beam position monitor pickup for the Iranian light source facility

    NASA Astrophysics Data System (ADS)

    Shafiee, M.; Feghhi, S. A. H.; Rahighi, J.

    2017-03-01

    In this paper, we describe the design of a button type Beam Position Monitor (BPM) for the low emittance storage ring of the Iranian Light Source Facility (ILSF). First, we calculate sensitivities, induced power and intrinsic resolution based on solving Laplace equation numerically by finite element method (FEM), in order to find the potential at each point of BPM's electrode surface. After the optimization of the designed BPM, trapped high order modes (HOM), wakefield and thermal loss effects are calculated. Finally, after fabrication of BPM, it is experimentally tested by using a test-stand. The results depict that the designed BPM has a linear response in the area of 2×4 mm2 inside the beam pipe and the sensitivity of 0.080 and 0.087 mm-1 in horizontal and vertical directions. Experimental results also depict that they are in a good agreement with numerical analysis.

  15. Managing business compliance using model-driven security management

    NASA Astrophysics Data System (ADS)

    Lang, Ulrich; Schreiner, Rudolf

    Compliance with regulatory and governance standards is rapidly becoming one of the hot topics of information security today. This is because, especially with regulatory compliance, both business and government have to expect large financial and reputational losses if compliance cannot be ensured and demonstrated. One major difficulty of implementing such regulations is caused the fact that they are captured at a high level of abstraction that is business-centric and not IT centric. This means that the abstract intent needs to be translated in a trustworthy, traceable way into compliance and security policies that the IT security infrastructure can enforce. Carrying out this mapping process manually is time consuming, maintenance-intensive, costly, and error-prone. Compliance monitoring is also critical in order to be able to demonstrate compliance at any given point in time. The problem is further complicated because of the need for business-driven IT agility, where IT policies and enforcement can change frequently, e.g. Business Process Modelling (BPM) driven Service Oriented Architecture (SOA). Model Driven Security (MDS) is an innovative technology approach that can solve these problems as an extension of identity and access management (IAM) and authorization management (also called entitlement management). In this paper we will illustrate the theory behind Model Driven Security for compliance, provide an improved and extended architecture, as well as a case study in the healthcare industry using our OpenPMF 2.0 technology.

  16. Association of heart rate at hospital discharge with mortality and hospitalizations in patients with heart failure.

    PubMed

    Habal, Marlena V; Liu, Peter P; Austin, Peter C; Ross, Heather J; Newton, Gary E; Wang, Xuesong; Tu, Jack V; Lee, Douglas S

    2014-01-01

    Heart failure (HF) is associated with a high burden of morbidity and mortality. Hospital discharge is an opportunity for identification of modifiable prognostic factors in the transition to chronic HF. We examined the association of discharge heart rate with 30-day and 1-year mortality and hospitalization outcomes in a cohort of 9097 patients with HF discharged from hospital. Discharge heart rate was categorized into predefined groups: 40 to 60 (n=1333), 61 to 70 (n=2170), 71 to 80 (n=2631), 81 to 90 (n=1700), and >90 bpm (n=1263). There was a significant increase in all-cause 30-day mortality with adjusted odds ratios of 1.59 (95% confidence interval [CI], 1.18-2.14; P=0.003) for discharge heart rates 81 to 90 bpm and 1.56 (95% CI, 1.13-2.16; P=0.007) for heart rates>90 bpm when compared with the reference group (heart rates, 61-70 bpm). Cardiovascular death risk at 30 days was also higher with adjusted odds ratio 1.59 (discharge heart rates, 81-90 bpm; 95% CI, 1.09-2.33; P=0.017) and 1.65 (discharge heart rates, >90 bpm; 95% CI, 1.09-2.48; P=0.017). One-year all-cause mortality (adjusted odds ratio, 1.41; 95% CI, 1.16-1.72; P<0.001) and cardiovascular death (adjusted odds ratio, 1.47; 95% CI, 1.12-1.92; P=0.005) were higher with discharge heart rates>90 bpm when compared with the reference group (heart rates, 40-60 bpm). Readmissions for HF (adjusted hazard ratio, 1.26; 95% CI, 1.04-1.54; P=0.021) and cardiovascular disease (adjusted hazard ratio, 1.29; 95% CI, 1.08-1.54; P=0.004) within 30 days were also higher with discharge heart rates>90 bpm. Higher discharge heart rates were associated with greater risk of all-cause and cardiovascular mortality≤1-year follow-up and an elevated risk of 30-day readmission for HF and cardiovascular disease.

  17. Crystallographic and general use programs for the XDS Sigma 5 computer

    NASA Technical Reports Server (NTRS)

    Snyder, R. L.

    1973-01-01

    Programs in basic FORTRAN 4 are described, which fall into three catagories: (1) interactive programs to be executed under time sharing (BTM); (2) non interactive programs which are executed in batch processing mode (BPM); and (3) large non interactive programs which require more memory than is available in the normal BPM/BTM operating system and must be run overnight on a special system called XRAY which releases about 45,000 words of memory to the user. Programs in catagories (1) and (2) are stored as FORTRAN source files in the account FSNYDER. Programs in catagory (3) are stored in the XRAY system as load modules. The type of file in account FSNYDER is identified by the first two letters in the name.

  18. Manually Operatable On-Chip Bistable Pneumatic Microstructures for Microfluidic Manipulations

    PubMed Central

    Chen, A.; Pan, T.

    2014-01-01

    Bistable microvalves are of particular interest because of their distinct nature requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries for microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integratability and small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPM) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly comprised of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), which users have direct control through finger pressing to switch between bistable vacuum state (VS) or atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that process blood samples to identify the distinct blood types (A/B/O) on chip. PMID:25007840

  19. A mobile system for assessment of physiological response to posture transitions.

    PubMed

    Jovanov, Emil; Milosevic, Mladen; Milenković, Aleksandar

    2013-01-01

    Posture changes initiate a dynamic physiological response that can be used as an indicator of the overall health status. We introduce an inconspicuous mobile wellness monitoring system (imWell) that continuously assesses the dynamic physiological response to posture transitions during activities of daily living. imWell utilizes a Zephyr BioHarness 3 physiological monitor that continually reports heart activity and physical activity via Bluetooth to a personal device (e.g. smartphone). The personal device processes the reported activity data in real-time to recognize posture transitions from the accelerometer data and to characterize dynamic heart response to posture changes. It annotates, logs, and uploads the heart activity data to our mHealth server. In this paper we present algorithms for detection of posture transitions and heart activity characterization during a sit-to-stand transition. The proposed system was tested on seven healthy subjects performing a predefined protocol. The total average and standard deviation for sit-to-stand transition time is 2.7 ± 0.69 s, resulting in the change of heart rate of 27.36 ± 9.30 bpm (from 63.3 ± 9.02 bpm to 90.66 ± 10.09 bpm).

  20. Identification of Arabidopsis MYB56 as a novel substrate for CRL3BPM E3 ligases.

    PubMed

    Chen, Liyuan; Bernhardt, Anne; Lee, JooHyun; Hellmann, Hanjo

    2014-10-24

    Controlled stability of proteins is a highly efficient mechanism to direct diverse processes in living cells. A key regulatory system for protein stability is given by the ubiquitin proteasome pathway, which uses E3 ligases to mark specific proteins for degradation. In this work MYB56 is identified as a novel target of a CULLIN3 (CUL3)-based E3 ligase. Its stability depends on the presence of MATH-BTB/POZ (BPM) proteins, which function as substrate adaptors to the E3 ligase. Genetic studies pointed out that MYB56 is a negative regulator of flowering, while BPMs positively affect this developmental program. The interaction between BPMs and MYB56 occurs at the promoter of FLOWERING LOCUS T (FT), a key regulator in initiating flowering in Arabidopsis, and results in instability of MYB56. Overall the work establishes MYB transcription factors as substrates of BPM proteins, and provides novel information on components that participate in controlling the flowering time point in plants. © The Author 2014. Published by the Molecular Plant Shanghai Editorial Office in association with Oxford University Press on behalf of CSPB and IPPE, SIBS, CAS.

  1. A high resolution cavity BPM for the CLIC Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chritin, N.; Schmickler, H.; Soby, L.

    2010-08-01

    In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

  2. Heart rate never lies: interventional cardiologist and Braude's quote revised

    PubMed Central

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Background Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. Objectives To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. Design This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Results Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Conclusions Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions. PMID:26835145

  3. Heart rate never lies: interventional cardiologist and Braude's quote revised.

    PubMed

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions.

  4. Use of Statechart Assertions for Modeling Human-in-the-Loop Security Analysis and Decision-Making Processes

    DTIC Science & Technology

    2012-06-01

    THIS PAGE INTENTIONALLY LEFT BLANK xv LIST OF ACRONYMS AND ABBREVIATIONS BPM Business Process Model BPMN Business Process Modeling Notation C&A...checking leads to an improvement in the quality and success of enterprise software development. Business Process Modeling Notation ( BPMN ) is an...emerging standard that allows business processes to be captured in a standardized format. BPMN lacks formal semantics which leaves many of its features

  5. Exercise Training Attenuates Sympathetic Activity and Improves Morphometry of Splenic Arterioles in Spontaneously Hipertensive Rats.

    PubMed

    Lemos, Marina de Paiva; Mota, Gustavo Ribeiro da; Marocolo, Moacir; Sordi, Carla Cristina de; Chriguer, Rosângela Soares; Barbosa Neto, Octávio

    2018-03-01

    Alterations in the structure of resistance vessels contribute to elevated systemic vascular resistance in hypertension and are linked to sympathetic hyperactivity and related lesions in target organs. To assess the effects of exercise training on hemodynamic and autonomic parameters, as well as splenic arteriolar damages in male Wistar Kyoto (WKY) and Spontaneously Hypertensive Rats (SHR). Normotensive sedentary (WKYS) and trained (WKYT) rats, and hypertensive sedentary (SHRS) and trained (SHRT) rats were included in this study. After 9 weeks of experimental protocol (swimming training or sedentary control), arterial pressure (AP) and heart rate (HR) were recorded in freely moving rats. We assessed the autonomic control of the heart by sympathetic and vagal autonomic blockade. Morphometric analyses of arterioles were performed in spleen tissues. The statistical significance level was set at p < 0.05. Resting bradycardia was observed in both trained groups (WKYT: 328.0 ± 7.3 bpm; SHRT: 337.0 ± 5.2 bpm) compared with their respective sedentary groups (WKYS: 353.2 ± 8.5 bpm; SHRS: 412.1 ± 10.4 bpm; p < 0.001). Exercise training attenuated mean AP only in SHRT (125.9 ± 6.2 mmHg) vs. SHRS (182.5 ± 4.2 mmHg, p < 0.001). The WKYT showed a higher vagal effect (∆HR: 79.0 ± 2.3 bpm) compared with WKYS (∆HR: 67.4 ± 1.7 bpm; p < 0.05). Chronic exercise decreased sympathetic effects on SHRT (∆HR: -62.8 ± 2.8 bpm) in comparison with SHRS (∆HR: -99.8 ± 9.2 bpm; p = 0.005). The wall thickness of splenic arterioles in SHR was reduced by training (332.1 ± 16.0 µm2 in SHRT vs. 502.7 ± 36.3 µm2 in SHRS; p < 0.05). Exercise training attenuates sympathetic activity and AP in SHR, which may be contributing to the morphological improvement of the splenic arterioles.

  6. Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose.

    PubMed

    Jiménez-Juan, Laura; Nguyen, Elsie T; Wintersperger, Bernd J; Moshonov, Hadas; Crean, Andrew M; Deva, Djeven P; Paul, Narinder S; Torres, Felipe S

    2013-01-01

    The purpose of this study was to evaluate the effect of intravenous (i.v.) metoprolol after a suboptimal heart rate (HR) response to oral metoprolol (75-150 mg) on HR control, image quality (IQ) and radiation dose during coronary CTA using 320-MDCT. Fifty-three consecutive patients who failed to achieve a target HR of < 60 bpm after an oral dose of metoprolol and required supplementary i.v. metoprolol (5-20 mg) prior to coronary CTA were evaluated. Patients with HR < 60 bpm during image acquisition were defined as responders (R) and those with HR ≥ 60 bpm as non-responders (NR). Two observers assessed IQ using a 3-point scale (1-2, diagnostic and 3, non-diagnostic). Effective dose (ED) was estimated using dose-length product and a 0.014 mSV/mGy.cm conversion factor. Baseline characteristics and HR on arrival were similar in the two groups. 58% of patients didn't achieve the target HR after receiving i.v. metoprolol (NR). R had a significantly higher HR reduction after oral (mean HR 63.9 ± 4.5 bpm vs. 69.6 ± 5.6 bpm) (p < 0.005) and i.v. (mean HR 55.4 ± 3.9 bpm vs. 67.4 ± 5.3 bpm) (p < 0.005) doses of metoprolol. Studies from NR showed a significantly higher ED in comparison to R (8.0 ± 2.9 vs. 6.1 ± 2.2 mSv) (p = 0.016) and a significantly higher proportion of non-diagnostic coronary segments (9.2 vs. 2.5%) (p < 0.001). 58% of patients who do not achieve a HR of <60 bpm prior to coronary CTA with oral fail to respond to additional i.v. metoprolol and have studies with higher radiation dose and worse image quality.

  7. Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography.

    PubMed

    Aguiar Rosa, Sílvia; Ramos, Ruben; Marques, Hugo; Santos, Rosana; Leal, Cecília; Casado, Helena; Saraiva, Márcia; Figueiredo, Luísa; Cruz Ferreira, Rui

    2016-12-01

    To evaluate the efficacy and safety of a heart rate (HR) reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography angiography (CCTA) with 64-slice multidetector computed tomography (64-MDCT). Patients who underwent cardiac 64-MDCT in a single institution between 2011 and 2014 were analyzed. Those with HR above 60 beats per minute (bpm) on presentation received oral metoprolol (50-200 mg) at least one hour before CCTA. Intravenous esmolol 1-2 mg/kg was administered as a bolus whenever HR remained over 65 bpm just before imaging. The primary efficacy endpoint was HR <65 bpm during CCTA. The primary safety endpoint was symptomatic hypotension or bradycardia up to hospital discharge. During the study period CCTA was performed in 947 cases. In 86% of these, oral metoprolol was the only medication required to successfully reduce HR <60 bpm. Esmolol was used in the remaining 130 patients (14%). For esmolol-treated patients mean baseline and acquisition HR were 74±14 bpm and 63±9 bpm, respectively (p<0.001). The target HR of <65 bpm was achieved in 82 of the 130 esmolol-treated patients (63%). Considering the whole population, esmolol use led to a significant increase in the primary efficacy endpoint from 86% to 95% (p<0.001). Esmolol also resulted in a statistically, but not clinically, significant reduction in systolic blood pressure (144±22 to 115±17 mmHg; p<0.001). The combined primary safety endpoint was only observed in two (1.5%) patients. Despite optimal use of oral beta-blockers, 14% of patients needed intravenous esmolol for HR control. The pre-medication combination of oral metoprolol and on-demand administration of intravenous esmolol was safe and effective and enabled 95% of patients to be imaged with HR below 65 bpm. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Heart rate at discharge and long-term prognosis following percutaneous coronary intervention in stable and acute coronary syndromes--results from the BASKET PROVE trial.

    PubMed

    Jensen, Magnus Thorsten; Kaiser, Christoph; Sandsten, Karl Erik; Alber, Hannes; Wanitschek, Maria; Iversen, Allan; Jensen, Jan Skov; Pedersen, Sune; Soerensen, Rikke; Rickli, Hans; Zurek, Marzena; Fahrni, Gregor; Bertel, Osmund; De Servi, Stefano; Erne, Paul; Pfisterer, Matthias; Galatius, Søren

    2013-10-09

    Elevated heart rate (HR) is associated with mortality in a number of heart diseases. We examined the long-term prognostic significance of HR at discharge in a contemporary population of patients with stable angina (SAP), non-ST-segment elevation acute coronary syndromes (NSTE-ACS), and ST-segment elevation myocardial infarction (STEMI) revascularized with percutaneous coronary intervention (PCI). Patients from the BASKET-PROVE trial, an 11-center randomized all-comers trial comparing bare-metal and drug-eluting stenting in large coronary vessels, were included. Discharge HR was determined from a resting ECG. Long-term outcomes (7 days to 2 years) were evaluated for all-cause mortality and cardiovascular death and non-fatal myocardial infarction. A total of 2029 patients with sinus rhythm were included, 722 (35.6%) SAP, 647 (31.9%) NSTE-ACS, and 660 (32.5%) STEMI. Elevated discharge HR was associated significantly with all-cause mortality: when compared to a reference of <60 beats per minute (bpm), the adjusted hazard ratios were (95% CI) 4.5 (1.5-13.5, p=0.006) for 60-69 bpm, 3.8 (1.2-11.9, p=0.022) for 70-79 bpm, 4.3 (1.2-15.6, p=0.025) for 80-89 bpm, and 16.9 (5.2-55.0, p<0.001) for >90 bpm. For cardiovascular death/myocardial infarction, a discharge HR >90 bpm was associated with a hazard ratio of 6.2 (2.5-15.5, p<0.001) compared to a HR <60 bpm. No interaction was found for disease presentation, diabetes or betablocker use. In patients revascularized with PCI for stable angina or acute coronary syndromes an elevated discharge HR was independently associated with poor prognosis. Conversely, a HR <60 bpm at discharge was associated with a good long-term prognosis irrespective of indication for PCI. © 2013.

  9. Utility of Time and Frequency Domain Parameters of Heart Rate Variability in the Context of Autonomic Disorders Characterized by Orthostatic Dysfunction.

    PubMed

    Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt

    2018-03-01

    The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.

  10. Central antioxidant therapy inhibits parasympathetic baroreflex control in conscious rats.

    PubMed

    Giusti, Marcelo Franchini; Sato, Monica Akemi; Cardoso, Leonardo Máximo; Braga, Valdir Andrade; Colombari, Eduardo

    2011-02-04

    Baroreceptor reflex is an important system for neural control of blood pressure. Recently, reactive oxygen species (ROS) have been shown to play an important role in neuronal activity of central areas related to blood pressure control. The aim of this study was to investigate the effects elicited by ascorbic acid (AAC) and N-acetylcysteine (NAC) injections into the 4thV on the parasympathetic component of the baroreflex. Male Wistar rats were implanted with a stainless steel guide cannula into the 4thV. One day prior to the experiments, the femoral artery and vein were cannulated for pulsatile arterial pressure, mean arterial pressure and heart rate measurements and drug administration, respectively. After baseline recordings, the baroreflex was tested with a pressor dose of phenylephrine (PHE, 3 μg/kg, i.v.) and a depressor dose of sodium nitroprusside (SNP, 30 μg/kg, i.v.) before (control) and 5, 15, 30 and 60 min after AAC or NAC into the 4thV. Control PHE injection induced baroreflex-mediated bradycardia (-93 ± 13 bpm, n=7). Interestingly, after AAC injection into the 4thV, PHE injection produced a transient tachycardia at 5 (40 ± 23 bpm), 15 (26 ± 22 bpm) and 30 min (59 ± 21 bpm). No changes were observed in baroreflex-mediated tachycardia evoked by SNP after AAC injection on 4thV (control: 151 ± 23bpm vs. 135 ± 18 bpm at 5 min after AAC, n=7). In the NAC treated group, PHE induced a reduction in reflex bradycardia at 5 min when compared to control (-11 ± 17 bpm vs. -83 ± 15 bpm, n=7). No changes were observed in baroreflex-mediated tachycardia evoked by SNP after NAC injection on 4thV. The antioxidants AAC and NAC may act in the central nervous system affecting the parasympathetic component of the cardiac baroreflex. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Association of Asymptomatic Bradycardia With Incident Cardiovascular Disease and Mortality: The Multi-Ethnic Study of Atherosclerosis (MESA).

    PubMed

    Dharod, Ajay; Soliman, Elsayed Z; Dawood, Farah; Chen, Haiying; Shea, Steven; Nazarian, Saman; Bertoni, Alain G

    2016-02-01

    Bradycardia has been associated with lower cardiovascular disease (CVD) risk in selected populations. There is a paucity of information available about heart rate (HR) less than 50 beats per minute (bpm) among middle-aged or older adults. To determine whether asymptomatic bradycardia was associated with a lower cardiovascular risk profile, less subclinical atherosclerosis, and decreased incident CVD and mortality. This retrospective analysis includes 6733 participants of the Multi-Ethnic Study of Atherosclerosis, which recruited men and women free of clinical cardiovascular disease ages 45 to 84 years from 2000 to 2002 and followed them over 10 years for incident CVD events and mortality. The HR was measured by baseline electrocardiogram. The analysis was performed in June 2014. The association between HR categories with CVD events and all-cause mortality were examined using Cox proportional hazards models adjusted for potential confounders and mediators. The 6733 participants had a mean (SD) age of 62 (10.2) years; 47% were male. The mean (SD) HR was 63 (9.5) bpm among the 5831 participants not taking an HR-modifying drug; 5.3% had an HR lower than 50 bpm. Preliminary results revealed significant interaction for HR categories according to use of HR-modifying drugs for mortality (P = .002); thus, all further analyses were stratified. An HR of less than 50 bpm was not associated with incident CVD in either subgroup (participants taking or not taking HR-modifying drugs). Among participants not taking HR-modifying drugs, the fully adjusted mortality risk was not different for an HR less than 50 bpm (hazard ratio, 0.71 [95% CI, 0.41-1.09]; P = .12) and increased among those with an HR greater than 80 bpm (hazard ratio, 1.49 [95% CI, 1.08-2.05]; P = .01) (reference HR, 60-69 bpm). Among the 902 participants taking HR-modifying drugs there was an elevated mortality risk associated with an HR less than 50 bpm (hazard ratio, 2.42 [95% CI, 1.39-4.20]; P = .002) and with an HR greater than 80 bpm (hazard ratio, 3.55 [95% CI, 1.65-7.65]; P = .001) (reference HR, 60-69 bpm). In a contemporary, community-based cohort, bradycardia was generally not associated with incident CVD or mortality except for a potential adverse association between bradycardia among those taking HR-modifying drugs.

  12. A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals

    PubMed Central

    Song, Jiajia; Li, Dan; Ma, Xiaoyuan; Teng, Guowei; Wei, Jianming

    2017-01-01

    Dynamic accurate heart-rate (HR) estimation using a photoplethysmogram (PPG) during intense physical activities is always challenging due to corruption by motion artifacts (MAs). It is difficult to reconstruct a clean signal and extract HR from contaminated PPG. This paper proposes a robust HR-estimation algorithm framework that uses one-channel PPG and tri-axis acceleration data to reconstruct the PPG and calculate the HR based on features of the PPG and spectral analysis. Firstly, the signal is judged by the presence of MAs. Then, the spectral peaks corresponding to acceleration data are filtered from the periodogram of the PPG when MAs exist. Different signal-processing methods are applied based on the amount of remaining PPG spectral peaks. The main MA-removal algorithm (NFEEMD) includes the repeated single-notch filter and ensemble empirical mode decomposition. Finally, HR calibration is designed to ensure the accuracy of HR tracking. The NFEEMD algorithm was performed on the 23 datasets from the 2015 IEEE Signal Processing Cup Database. The average estimation errors were 1.12 BPM (12 training datasets), 2.63 BPM (10 testing datasets) and 1.87 BPM (all 23 datasets), respectively. The Pearson correlation was 0.992. The experiment results illustrate that the proposed algorithm is not only suitable for HR estimation during continuous activities, like slow running (13 training datasets), but also for intense physical activities with acceleration, like arm exercise (10 testing datasets). PMID:29068403

  13. BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weathersby, Stephen; Novokhatski, Alexander; /SLAC

    2010-02-10

    High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.

  14. Noise estimation of beam position monitors at RHIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, X.; Bai, M.; Lee, S. Y.

    2014-02-10

    Beam position monitors (BPM) are used to record the average orbits and transverse turn-by-turn displacements of the beam centroid motion. The Relativistic Hadron Ion Collider (RHIC) has 160 BPMs for each plane in each of the Blue and Yellow rings: 72 dual-plane BPMs in the insertion regions (IR) and 176 single-plane modules in the arcs. Each BPM is able to acquire 1024 or 4096 consecutive turn-by-turn beam positions. Inevitably, there are broadband noisy signals in the turn-by-turn data due to BPM electronics as well as other sources. A detailed study of the BPM noise performance is critical for reliable opticsmore » measurement and beam dynamics analysis based on turn-by-turn data.« less

  15. Cavity BPM system tests for the ILC energy spectrometer

    NASA Astrophysics Data System (ADS)

    Slater, M.; Adolphsen, C.; Arnold, R.; Boogert, S.; Boorman, G.; Gournaris, F.; Hildreth, M.; Hlaing, C.; Jackson, F.; Khainovski, O.; Kolomensky, Yu. G.; Lyapin, A.; Maiheu, B.; McCormick, D.; Miller, D. J.; Orimoto, T. J.; Szalata, Z.; Thomson, M.; Ward, D.; Wing, M.; Woods, M.

    2008-07-01

    The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10-4 or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 h for a 1 m long BPM triplet. We find micron-level stability over 1 h for 3 BPM stations distributed over a 30 m long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.

  16. Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients

    PubMed Central

    Akgöz, Ayça; Akata, Deniz; Hazırolan, Tuncay; Karçaaltıncaba, Muşturay

    2014-01-01

    PURPOSE We aimed to evaluate the visibility of coronary arteries and bypass-grafts in patients who underwent dual source computed tomography (DSCT) angiography without heart rate (HR) control and to determine optimal intervals for image reconstruction. MATERIALS AND METHODS A total of 285 consecutive cases who underwent coronary (n=255) and bypass-graft (n=30) DSCT angiography at our institution were identified retrospectively. Patients with atrial fibrillation were excluded. Ten datasets in 10% increments were reconstructed in all patients. On each dataset, the visibility of coronary arteries was evaluated using the 15-segment American Heart Association classification by two radiologists in consensus. RESULTS Mean HR was 76±16.3 bpm, (range, 46–127 bpm). All coronary segments could be visualized in 277 patients (97.19%). On a segment-basis, 4265 of 4275 (99.77%) coronary artery segments were visible. All segments of 56 bypass-grafts in 30 patients were visible (100%). Total mean segment visibility scores of all coronary arteries were highest at 70%, 40%, and 30% intervals for all HRs. The optimal reconstruction intervals to visualize the segments of all three coronary arteries in descending order were 70%, 60%, 80%, and 30% intervals in patients with a mean HR <70 bpm; 40%, 70%, and 30% intervals in patients with a mean HR 70–100 bpm; and 40%, 50%, and 30% in patients with a mean HR >100 bpm. CONCLUSION Without beta-blocker administration, DSCT coronary angiography offers excellent visibility of vascular segments using both end-systolic and mid-late diastolic reconstructions at HRs up to 100 bpm, and only end-systolic reconstructions at HRs over 100 bpm. PMID:24834490

  17. Prognostic impact of heart rate in elderly with systolic heart failure and concomitant atrial fibrillation.

    PubMed

    Barywani, Salim; Petzold, Max

    2017-08-01

    The present study aimed to investigate the impact of resting heart rate (HR) on 5-year all-cause mortality in patients ≥80 years with heart failure (HF) with reduced ejection fraction (HFrEF) and concomitant atrial fibrillation (AF) after optimal up-titration of beta-blockers (BBs). Patients (n = 185) aged ≥80 years with HF and left ventricular ejection fraction ≤40% were included between January 2000 and January 2008 from two university hospitals, Sahlgrenska and Östra and retrospectively studied from January 2 to May 30, 2013. Up-titrations of guideline recommended medications were performed at HF outpatient clinics. Of whole study population, 54% (n= 100) had AF. After optimal up-titration of BBs and angiotensin converting enzyme inhibitors (ACEIs)/angiotensin receptor blockers (ARBs), mean HR in patients with AF was 73 ± 15 beats/minute (bpm), 36% had resting HR ≤65 bpm. Five-year all-cause mortality among patients with AF was significantly lower in patients with HR ≤65 bpm (63%) compared to HR >65 (80%). Cox proportional-hazard regression analysis adjusted for clinically important baseline variables and doses of ACEIs/ARBs and BBs demonstrated resting HR ≤65 bpm as an independent predictor of improved survival compared to resting HR >65 bpm (HR 0.3, 95%CI 0.1-0.7, P 0.005). In octogenarians with HFrEF and concomitant AF, lowering resting HR to levels as low as HR ≤65 bpm was still associated with improved survival from all-cause mortality. Our data indicate that mortality in AF became comparable to SR when patients were on maximally up-titrated beta-blocker doses with HR as low as 75 bpm.

  18. Dependency of exercise-induced T-wave alternans predictive power for the occurrence of ventricular arrhythmias from heart rate.

    PubMed

    Burattini, Laura; Man, Sumche; Fioretti, Sandro; Di Nardo, Francesco; Swenne, Cees A

    2015-07-01

    T-wave alternans (TWA) is a noninvasive index of risk for the occurrence of ventricular arrhythmias. It is known that TWA amplitude (TWAA) increases with heart rate (HR) but how the TWA predictive power varies with HR remains unknown. Thus, the aim of this study was to evaluate the dependency of exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias from HR. TWA was identified using our HR adaptive match filter in exercise ECGs from 248 patients with implanted cardiac defibrillator (ICD), of which 72 developed ventricular tachycardia and/or fibrillation during the 4 year follow-up (ICD_Cases) and 176 did not (ICD_Controls). TWA predictive power was evaluated at HRs from 80 to 120 bpm by computing the area under the receiver operating characteristic curve (AUC) obtained using the maximum TWAA (maxTWAA) and the TWAA ratio (TWAAratio; i.e., the ratio between TWAA at a specific HR and at 80 bpm). TWAA increased with HR. At 80 bpm maxTWAA was lower than at 120 bpm in both ICD_Cases (22 μV vs 41 μV; P < 10(-2) ) and ICD_ Controls (16 μV vs 36 μV; P < 10(-4) ). However, only at 80 bpm ICD_Cases showed significantly higher maxTWAA than ICD_Controls (AUC = 0.6486; P = 0.0080). TWAAratio was higher in ICD_Controls than ICD_Cases for all HR but 120 bpm, and its predictive power was maximum at 115 bpm (AUC = 0.6914; P < 0.05). Exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias, quantified using both maxTWAA and TWAAratio, was higher at low rather than at high HR. © 2014 Wiley Periodicals, Inc.

  19. Reliability and Validity the Brief Problem Monitor, an Abbreviated Form of the Child Behavior Checklist

    PubMed Central

    Piper, Brian J.; Gray, Hilary M.; Raber, Jacob; Birkett, Melissa A.

    2014-01-01

    Aim The parent form of the 113 item Child Behavior Checklist (CBCL) is widely utilized by child psychiatrists and psychologists. This report examines the reliability and validity of a recently developed abbreviated version of the CBCL, the Brief Problem Monitor (BPM). Methods Caregivers (N=567) completed the CBCL online and the 19 BPM items were examined separately. Results Internal consistency of the BPM was high (Cronbach’s alpha=0.91) and satisfactory for the Internalizing (0.78), Externalizing (0.86), and Attention (0.87) scales. High correlations between the CBCL and BPM were identified for the total score (r=0.95) as well as the Internalizing (0.86), Externalizing (0.93), and Attention (0.97) scales. The BPM and scales were sensitive and identified significantly higher behavioral and emotional problems among children whose caregiver reported a psychiatric diagnosis of Attention Deficit Hyperactivity Disorder, bipolar, depression, anxiety, developmental disabilities, or Autism Spectrum Disorders relative to a comparison group that had not been diagnosed with these disorders. BPM ratings also differed by the socioeconomic status and education of the caregiver. Mothers with higher annual incomes rated their children as having 38.8% fewer total problems (Cohen’s d=0.62) as well as 42.8% lower Internalizing (d=0.53), 44.1% less Externalizing (d=0.62), and 30.9% decreased Attention (d=0.39). A similar pattern was evident for maternal education (d=0.30 to 0.65). Conclusion Overall, these findings provide strong psychometric support for the BPM although the differences based on the characteristics of the parent indicates that additional information from other sources (e.g., teachers) should be obtained to complement parental reports. PMID:24735087

  20. Heart rate in patients with reduced ejection fraction: relationship between single time point measurement and mean heart rate on prolonged implantable cardioverter defibrillator monitoring.

    PubMed

    Habal, Marlena V; Nanthakumar, Kumaraswamy; Austin, Peter C; Freitas, Cassandra; Labos, Christopher; Lee, Douglas S

    2018-01-31

    Heart rate (HR) is a prognostic marker that is increasingly used as a therapeutic target in patients with cardiovascular disease. The association between resting and mean HR remains unclear. We therefore set out to determine the relationship between resting HR on the electrocardiogram (ECG) obtained at a single time point, and mean HR on implantable cardioverter defibrillator (ICD) interrogation amongst patients with a reduced left ventricular ejection fraction (LVEF). Prospective ICD data were obtained from 54 patients with LVEF < 40%. Mean HR determined using the ICD HR histograms was compared with resting HR measured on the ECG performed in the clinic. Average resting and ICD mean HRs were 67.9 ± 10.1 and 67.8 ± 9.6 bpm respectively. There was good correlation in the overall cohort (r = 0.79), in those with resting ECG HRs ≤ 70 bpm (r = 0.62), and amongst the 27 patients on intermediate-to-high dose beta-blockers (r = 0.91). However, Bland-Altman analysis demonstrated wide limits of agreement in the overall cohort (- 12.5, 12.7 bpm), at resting HRs ≤ 70 bpm (- 12.7, 9.8 bpm), and on intermediate-to-high dose beta-blockers (- 8.9, 7.4 bpm). Moreover, resting HR did not predict the 10-bpm interval where the most time was spent. While resting HR correlated with mean HR in patients with reduced LVEF, and in important subgroups, the limits of agreement were unacceptably wide raising concern over the use of single time point resting HR as a therapeutic target.

  1. Comparing the Effects of Rest and Massage on Return to Homeostasis Following Submaximal Aerobic Exercise: a Case Study.

    PubMed

    Resnick, Portia B

    2016-03-01

    Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject's heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session.

  2. Renal sympathetic denervation improves rate control in patients with symptomatic persistent atrial fibrillation and hypertension.

    PubMed

    Qiu, Min; Shan, Qijun; Chen, Chun; Geng, Jie; Guo, Jiqun; Zhou, Xiujuan; Qian, Weichong; Tang, Lijun; Yin, Yuehui

    2016-02-01

    The aim of this study was to investigate whether renal sympathetic denervation (RSD) improves ventricular heart rate (HR) control in patients with persistent atrial fibrillation (AF). Twenty-one patients (aged 57.5 ± 10.2 years, 76.2% male) with persistent AF and hypertension underwent RSD and completed 7-days follow-up evaluations, including 24-hour Holter monitoring (Holter), blood pressure (BP), 24-hour ambulatory BP monitoring (ABPM). Patients were grouped into tertiles of average HR at baseline Holter recording for evaluation of RSD effects on atrioventricular (AV) node (group 1: HR ≧ 90 bpm; group 2: 80 bpm ≦ HR < 90 bpm; group 3: HR < 80 bpm). All patients successfully underwent RSD without any complications. The clinical and procedural characteristics were similar in all groups of patients. No significant changes in BP were observed in the three groups before and after RSD. Compared with baseline, the average HR (Holter) of patients in group 1, 2 and 3 had a reduction of 22.6 ± 13.2 bpm (83.3 ± 4.9 vs 106.0 ± 14.6, P = 0.004), 9.7 ± 7.8 bpm (75.7 ± 7.6 vs 85.4 ± 3.7, P = 0.017) and 2.3 ± 2.9 bpm (71.4 ± 4.0 vs 73.7 ± 4.7, P = 0.089) at 7 days after RSD, respectively. RSD could improve ventricular HR control in patients with persistent AF. RSD slowed AV node conduction in baseline HR-dependent manner. RSD may become an alternative non-pharmaceutical tool for rate control in patients with persistent AF.

  3. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    USGS Publications Warehouse

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged < 10 sec. During agonistic encounters, heart rate exceeded 400 BPM; heart rates during social interactions were not predictable solely from postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  4. Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

    NASA Astrophysics Data System (ADS)

    Xu, Wei; Li, Jing-Yi; Huang, Sen-Lin; Z. Wu, W.; Hao, H.; P., Wang; K. Wu, Y.

    2014-10-01

    The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). It is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

  5. Electronic digital display watch having solar and geographical functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salah, I.M.

    1984-10-30

    In order to provide easily accessible knowledge of the correlations between time, the geographical locale and the solar positions, the watch in question in addition to time-keeping means capable of displaying the current time also provides means capable of storing, processing in a microprocessor mode and displaying in a particular panel mode data of solar elevation and azimuth as well as date data, a computer performing correlating operations between these various values. Pushbuttons (BPH', BPM', BPB') allow using this watch in various operational and correction situations, and other pushbuttons (BPH, BPM, BPB) allow more specific commands for correction, for searchmore » operations regarding date and place based on the solar data, for storage and call from memory of the various processed data. This watch can easily be implemented as a small wrist watch. It will be advantageously used by those interested in knowing the solar positions, by solar facility engineers, architects, airline pilots, believers in the Moslem faith etc.« less

  6. A full vectorial generalized discontinuous Galerkin beam propagation method (GDG-BPM) for nonsmooth electromagnetic fields in waveguides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan Kai; Cai Wei; Ji Xia

    2008-07-20

    In this paper, we propose a new full vectorial generalized discontinuous Galerkin beam propagation method (GDG-BPM) to accurately handle the discontinuities in electromagnetic fields associated with wave propagations in inhomogeneous optical waveguides. The numerical method is a combination of the traditional beam propagation method (BPM) with a newly developed generalized discontinuous Galerkin (GDG) method [K. Fan, W. Cai, X. Ji, A generalized discontinuous Galerkin method (GDG) for Schroedinger equations with nonsmooth solutions, J. Comput. Phys. 227 (2008) 2387-2410]. The GDG method is based on a reformulation, using distributional variables to account for solution jumps across material interfaces, of Schroedinger equationsmore » resulting from paraxial approximations of vector Helmholtz equations. Four versions of the GDG-BPM are obtained for either the electric or magnetic field components. Modeling of wave propagations in various optical fibers using the full vectorial GDG-BPM is included. Numerical results validate the high order accuracy and the flexibility of the method for various types of interface jump conditions.« less

  7. Detection of Instrumental Drifts in the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wittmer, W.; Fisher, A.S.; Martin, D.J.

    2007-11-07

    During the last PEP-II run a major goal was to bring the Low-Energy Ring optics as close as possible to the design. A large number of BPMs exhibited sudden artificial jumps that interfered with this effort. The source of the majority of these jumps had been traced to the filter-isolator boxes (FIBs) near the BPM buttons. A systematic approach to find and repair the failing units had been developed and implemented. Despite this effort, the instrumental orbit jumps never completely disappeared. To trace the source of this behavior a test setup, using a spare Bergoz MX-BPM processor (kindly provided bymore » SPEAR III at SSRL), was connected in parallel to various PEP-II BPM processors. In the course of these measurements a slow instrumental orbit drift was found which was clearly not induced by a moving positron beam. Based on the size of the system and the limited time before PEP-II closes in Oct.2008, an accelerator improvement project was initiated to install BERGOZ BPM-MX processors close to all sextupoles.« less

  8. A Reverse-Translational Approach to Bipolar Disorder: Rodent and human studies in the Behavioral Pattern Monitor

    PubMed Central

    Young, Jared W.; Minassian, Arpi; Paulus, Martin P.; Geyer, Mark A.; Perry, William

    2007-01-01

    Mania is the defining feature of Bipolar Disorder (BD). There has been limited progress in understanding the neurobiological underpinnings of BD mania and developing novel therapeutics, in part due to a paucity of relevant animal models with translational potential. Hyperactivity is a cardinal symptom of mania, traditionally measured in humans using observer-rated scales. Multivariate assessment of unconditioned locomotor behavior using the rat Behavioral Pattern Monitor (BPM) developed in our laboratory has shown that hyperactivity includes complex multifaceted behaviors. The BPM has been used to demonstrate differential effects of drugs on locomotor activity and exploratory behavior in rats. Studies of genetically engineered mice in a mouse BPM have confirmed its utility as a cross-species tool. In a “reverse-translational” approach to this work, we developed the human BPM to characterize motor activity in BD patients. Increased activity, object interactions, and altered locomotor patterns provide multidimensional phenotypes to model in the rodent BPM. This unique approach to modeling BD provides an opportunity to identify the neurobiology underlying BD mania and test novel antimanic agents. PMID:17706782

  9. Rosiglitazone Improves Insulin Sensitivity and Baroreflex Gain in Rats with Diet-Induced Obesity

    PubMed Central

    Zhao, Ding; McCully, Belinda H.

    2012-01-01

    Obesity decreases baroreflex gain (BRG); however, the mechanisms are unknown. We tested the hypothesis that impaired BRG is related to the concurrent insulin resistance, and, therefore, BRG would be improved after treatment with the insulin-sensitizing drug rosiglitazone. Male rats fed a high-fat diet diverged into obesity-prone (OP) and obesity-resistant (OR) groups after 2 weeks. Then, OP and OR rats, as well as control (CON) rats fed a standard diet, were treated daily for 2 to 3 weeks with rosiglitazone (3 or 6 mg/kg) or its vehicle by gavage. Compared with OR and CON rats, conscious OP rats exhibited reductions in BRG (OP, 2.9 ± 0.1 bpm/mm Hg; OR, 4.0 ± 0.2 bpm/mm Hg; CON, 3.9 ± 0.2 bpm/mm Hg; P < 0.05) and insulin sensitivity (hyperinsulinemic euglycemic clamp; OP, 6.8 ± 0.9 mg/kg · min; OR, 22.2 ± 1.2 mg/kg · min; CON, 17.7 ± 0.8 mg/kg · min; P < 0.05), which were well correlated (r2 = 0.49; P < 0.01). In OP rats, rosiglitazone dose-dependently improved (P < 0.05) insulin sensitivity (12.8 ± 0.6 mg/kg · min at 3 mg/kg; 16.0 ± 1.5 mg/kg · min at 6 mg/kg) and BRG (3.8 ± 0.4 bpm/mm Hg at 3 mg/kg; 5.3 ± 0.7 bpm/mm Hg at 6 mg/kg). However, 6 mg/kg rosiglitazone also increased BRG in OR rats without increasing insulin sensitivity, disrupted the correlation between BRG and insulin sensitivity (r2 = 0.08), and, in OP and OR rats, elevated BRG relative to insulin sensitivity (analysis of covariance; P < 0.05). Moreover, in OP rats, stimulation of the aortic depressor nerve, to activate central baroreflex pathways, elicited markedly reduced decreases in heart rate and arterial pressure, but these responses were not improved by rosiglitazone. In conclusion, diet-induced obesity impairs BRG via a central mechanism that is related to the concurrent insulin resistance. Rosiglitazone normalizes BRG, but not by improving brain baroreflex processing or insulin sensitivity. PMID:22815534

  10. Cavity BPM System Tests for the ILC Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slater, M.

    2007-12-21

    The main physics program of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10{sup -4} or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a 1 m long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a 30 m long baseline. The understanding ofmore » the behavior and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.« less

  11. Video-based heart rate monitoring across a range of skin pigmentations during an acute hypoxic challenge.

    PubMed

    Addison, Paul S; Jacquel, Dominique; Foo, David M H; Borg, Ulf R

    2017-11-09

    The robust monitoring of heart rate from the video-photoplethysmogram (video-PPG) during challenging conditions requires new analysis techniques. The work reported here extends current research in this area by applying a motion tolerant algorithm to extract high quality video-PPGs from a cohort of subjects undergoing marked heart rate changes during a hypoxic challenge, and exhibiting a full range of skin pigmentation types. High uptimes in reported video-based heart rate (HR vid ) were targeted, while retaining high accuracy in the results. Ten healthy volunteers were studied during a double desaturation hypoxic challenge. Video-PPGs were generated from the acquired video image stream and processed to generate heart rate. HR vid was compared to the pulse rate posted by a reference pulse oximeter device (HR p ). Agreement between video-based heart rate and that provided by the pulse oximeter was as follows: Bias = - 0.21 bpm, RMSD = 2.15 bpm, least squares fit gradient = 1.00 (Pearson R = 0.99, p < 0.0001), with a 98.78% reporting uptime. The difference between the HR vid and HR p exceeded 5 and 10 bpm, for 3.59 and 0.35% of the reporting time respectively, and at no point did these differences exceed 25 bpm. Excellent agreement was found between the HR vid and HR p in a study covering the whole range of skin pigmentation types (Fitzpatrick scales I-VI), using standard room lighting and with moderate subject motion. Although promising, further work should include a larger cohort with multiple subjects per Fitzpatrick class combined with a more rigorous motion and lighting protocol.

  12. BPM CALIBRATION INDEPENDENT LHC OPTICS CORRECTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CALAGA,R.; TOMAS, R.; GIOVANNOZZI, M.

    2007-06-25

    The tight mechanical aperture for the LHC imposes severe constraints on both the beta and dispersion beating. Robust techniques to compensate these errors are critical for operation of high intensity beams in the LHC. We present simulations using realistic errors from magnet measurements and alignment tolerances in the presence of BPM noise. Correction reveals that the use of BPM calibration and model independent observables are key ingredients to accomplish optics correction. Experiments at RHIC to verify the algorithms for optics correction are also presented.

  13. Evaluation of Heat Dissipation in the BPM Buttons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Blednyhk, A.

    2009-05-04

    Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.

  14. A BPM calibration procedure using TBT data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, M.J.; Crisp, J.; Prieto, P.

    2007-06-01

    Accurate BPM calibration is crucial for lattice analysis. It is also reassuring when the calibration can be independently verified. This paper outlines a procedure that can extract BPM calibration information from TBT orbit data. The procedure is developed as an extension to the Turn-By-Turn lattice analysis [1]. Its application to data from both Recycler Ring and Main Injector (MI) at Fermilab have produced very encouraging results. Some specifics in hardware design will be mentioned to contrast that of analysis results.

  15. Deep-Diving California Sea Lions: Are They Pushing Their Physiological Limit

    DTIC Science & Technology

    2015-09-30

    resting heart rate (70 bpm ) (Ponganis et al. 1997) is reached, and e) duration of and heart rate during the ascent tachycardia. If possible, heart rate...Resting heart rates were 54 + 6 beats min-1 ( bpm ), and in dives of 1-3 min, 3-5 min, and > 5 min, dive heart rates (number of beats/dive duration...were 55 + 8, 51 + 6, and 40 + bpm . As illustrated in Figs. 1 and 2, the heart rate profile was characterized by rapid development of a bradycardia

  16. Increased Heart Rate Is Associated With Higher Mortality in Patients With Atrial Fibrillation (AF): Results From the Outcomes Registry for Better Informed Treatment of AF (ORBIT-AF)

    PubMed Central

    Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P

    2015-01-01

    Background Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. Methods and Results We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Conclusions Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. Clinical Trial Registration URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. PMID:26370445

  17. Evaluation of anti-asthmatic and antioxidant potential of Boerhavia procumbens in toluene diisocyanate (TDI) treated rats.

    PubMed

    Bokhari, Jasia; Khan, Muhammad Rashid

    2015-08-22

    Asthma is an ailment of airways characterized by activation of the T helper (Th) 2 lymphocytes and subsequent movement of inflammatory cells. Boerhavia procumbens of family Nyctaginaceae is locally used for the treatment of asthma, cough, hemorrhoids, dropsy, cardiac, eyes and kidney problems. We have evaluated its methanol extract (BPM) as a therapeutic candidate for asthma against toluene diisocyanate (TDI) allergic model in rat. The BPM extract was obtained from the whole plant of B. procumbens in methanol. Sprague-Dawley male 36 rats (200-250 g) were categorized into 6 groups having six rats in each category. The animals were provoked (10%) and sensitized (5%) by TDI. Animals of groups I-III were vehicle control (ethyl acetate), diseased control (TDI) and reference control (TDI+dexamethasone {2.5mg/kg bw}), respectively. Animals of group IV (TDI+200mg/kg bw) and group V (TDI+400mg/kg bw) were administered with BPM whereas group VI was administered with 400mg/kg bw alone of BPM. Protective effects of BPM were determined by counting the number of leucocytes and estimation of interleukines in blood, bronchoalveolar lavage (BAL) and in in vitro culture of spleen cells. Estimation of antioxidant enzymes, lipid peroxides and H2O2 and histopathology of lungs were carried out for antioxidant potential of plant extract used. Methanol extract of B. procumbens suppressed the asthmatic symptoms and inhibited the infiltration of eosinophils and lymphocytes in lungs of TDI provoked rats. Administration of BPM to TDI provoked rats, dose dependently, inhibited the release of interleukins (IL)-2 in serum and IL-4, IL-6 interferon gamma (IFN-γ) in bronchoalveolar lavage (BAL) and in in vitro culture of spleen cells, and ameliorated the oxidative stress in lung tissues. Quantitative scoring of the lung histopathology exhibited protective effects of BPM and the inflammation, mucus, thickening of peribronchial smooth muscle layer and subepithelial deposition of collagen induced with TDI were ameliorated. The BPM has the anti-inflammatory properties that may be used to treat the asthma and inflammatory related ailments. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Increased Heart Rate Is Associated With Higher Mortality in Patients With Atrial Fibrillation (AF): Results From the Outcomes Registry for Better Informed Treatment of AF (ORBIT-AF).

    PubMed

    Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P

    2015-09-14

    Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  19. CCISS, Vascular and BP Reg: Canadian space life science research on ISS

    NASA Astrophysics Data System (ADS)

    Hughson, Richard L.; Shoemaker, J. Kevin; Arbeille, Philippe

    2014-11-01

    A comprehensive goal of the Canadian Space Agency studies (CCISS, Vascular and BP Reg) has been to investigate the efficacy of current exercise countermeasures to maintain cardiovascular and cerebrovascular health on return to Earth after up to 6-months in space. Results from the CCISS experiments revealed no significant change of in-flight heart rate during daily activities or sleep, and small, but variable between astronauts, post-flight elevation. The between astronaut differences were exaggerated during measurement of spontaneous baroreflex slope, which was reduced post-flight (P<0.05) during paced breathing with 3 astronauts having significant correlations between reduced baroreflex and reduced RR-interval (consistent with reduced fitness). Cerebrovascular autoregulation and CO2 response were mildly impaired after flight. Some loss of in-flight fitness of astronauts in Vascular was reflected by the increase in HR at a work rate of 161±46 W of 12.3±10.5 bpm, 10.4±5.9 bpm and 13.4±5.7 bpm for early-flight, late-flight and R+1, respectively. On return to gravity, changes in resting heart rate for supine (5.9±3.5 bpm), sit (8.1±3.3 bpm) and stand (10.3±10.0 bpm) were small but variable between individuals (from -5 bpm to +20 bpm in post-flight standing) and not related to the change in exercise heart rate. In Vascular astronauts, pulse wave transit time measured to the finger tended to be reduced post-flight and carotid artery distensibility was significantly reduced (P=0.03, and n=6). The heart rate and baroreflex data suggest that some astronauts return with cardiovascular deconditioning in spite of the exercise regimes. However, greater arterial stiffness is common among all astronauts studied to date. The new CSA project, BP Reg, will monitor inflight blood pressure in an attempt to identify astronauts in greater need for countermeasures. Future research should focus on whether Vascular changes in astronauts might make them an appropriate model to study the mechanisms of arterial aging on Earth.

  20. Concurrent validity of resting pulse-rate measurements: a comparison of 2 smartphone applications, the polar H7 belt monitor, and a pulse oximeter with bluetooth.

    PubMed

    Cheatham, Scott W; Kolber, Morey J; Ernst, Michael P

    2015-05-01

    Pulse rate is commonly measured manually or with commercial wrist or belt monitors. More recently, pulse-rate monitoring has become convenient with the use of mobile technology that allows monitoring through a smartphone camera. This optical technology offers many benefits, although the clinimetric properties have not been extensively studied. Observational study of reliability Setting: University kinesiology laboratory. 30 healthy, recreationally active adults. Concurrent measurement of pulse rate using 2 smartphone applications (fingertip, face-scan,) with the Polar H7 belt and pulse oximeter. Average resting pulse rate for 5 min in 3 positions (supine, sitting, and prone). Concurrent validity in supine and standing was good between the 2 applications and the Polar H7 (intraclass correlation coefficient [ICC] .80-.98) and pulse oximeter (ICC .82-.98). For sitting, the validity was good between the fingertip application, Polar H7 (ICC .97), and pulse oximeter (ICC .97). The face-scan application had moderate validity with the Polar H7 (ICC .74) and pulse oximeter (ICC .69). The minimal detectable change (MDC90) between the fingertip application and Polar H7 ranged from 1.38 to 4.36 beats/min (BPM) and from 0.69 to 2.97 BPM for the pulse oximeter with both positions. The MDC90 between the face-scan application and Polar H7 ranged from 11.88 to 12.83 BPM and from 0.59 to 17.72 BPM for the pulse oximeter. The 95% limits of agreement suggest that the fingertip application may vary between 2.40 and 3.59 BPM with the Polar H7 and between 3.40 and 3.42 BPM with the pulse oximeter. The face-scan application may vary between 3.46 and 3.52 BPM with the Polar H7 and between 2.54 and 3.46 BPM with the pulse oximeter. Pulse-rate measurements may be effective using a fingertip application, belt monitor, and pulse oximeter. The fingertip scanner showed superior results compared with the face scanner, which only demonstrated modest validity compared with the Polar H7 and pulse oximeter.

  1. Bladder pressure measurements and urinary tract infection in trauma patients.

    PubMed

    Duane, Therèse M; Young, Andrew; Weber, William; Wolfe, Luke G; Malhotra, Ajai K; Aboutanos, Michel B; Whelan, James F; Mayglothling, Julie; Ivatury, Rao R

    2012-04-01

    The purpose of this trial was to determine if using a closed technique for bladder pressure measurements (BPMs) would eliminate them as a risk factor for urinary tract infection (UTI) in trauma patients, as was shown previously using an open technique. Data were collected prospectively from January 2006 until December 2009 by a dedicated epidemiology nurse and combined with trauma registry data at our Level 1 trauma center. All trauma patients admitted to the surgical trauma intensive care unit (STICU) with and without UTIs were compared for demographic and epidemiologic data. A closed system was used in which the urinary drainage catheter (UDC) remained connected to the bag and 45 mL of saline was injected through a two-way valved sideport, with subsequent measurements through the sideport. There were 1,641 patients in the trial. The UTI group was sicker (Injury Severity Score [ISS] 18.7±11.9 no UTI vs. 28±10.7 UTI; p<0.0001), with longer stays (11.4±12.4 days no UTI vs. 37.9±20.3 days UTI; p<0.0001) and more UDC days (4.3±6.6 no UTI vs. 23.9±16.6 UTI; p<0.0001). The BPM group had more UDC days (15.6 days±16.0 BPM vs. 5.4 days±7.3 no BPM; p<0.0001), yet no difference in UTI rate/1,000 UDC days (5.7 no BPM vs. 8.0 BPM; p=0.5291). Logistic regression demonstrated only UDC days to be a predictor of UTI (1.125; 95% confidence interval [CI] 1.097-1.154; p<0.0001), whereas ISS (1.083, 95% CI 1.063-1.104; p<0.0001) and age (1.051, 95% CI 1.037-1.065; p<0.0001) were the only predictors of death. Although patients undergoing BPM have more UTIs than patients without BPM, the measurements are not an independent predictor of UTI when done by the closed technique. These findings emphasize the judicious use of BPM with a closed system and, more importantly, the need for early removal of catheters.

  2. Precision PEP-II optics measurement with an SVD-enhanced Least-Square fitting

    NASA Astrophysics Data System (ADS)

    Yan, Y. T.; Cai, Y.

    2006-03-01

    A singular value decomposition (SVD)-enhanced Least-Square fitting technique is discussed. By automatic identifying, ordering, and selecting dominant SVD modes of the derivative matrix that responds to the variations of the variables, the converging process of the Least-Square fitting is significantly enhanced. Thus the fitting speed can be fast enough for a fairly large system. This technique has been successfully applied to precision PEP-II optics measurement in which we determine all quadrupole strengths (both normal and skew components) and sextupole feed-downs as well as all BPM gains and BPM cross-plane couplings through Least-Square fitting of the phase advances and the Local Green's functions as well as the coupling ellipses among BPMs. The local Green's functions are specified by 4 local transfer matrix components R12, R34, R32, R14. These measurable quantities (the Green's functions, the phase advances and the coupling ellipse tilt angles and axis ratios) are obtained by analyzing turn-by-turn Beam Position Monitor (BPM) data with a high-resolution model-independent analysis (MIA). Once all of the quadrupoles and sextupole feed-downs are determined, we obtain a computer virtual accelerator which matches the real accelerator in linear optics. Thus, beta functions, linear coupling parameters, and interaction point (IP) optics characteristics can be measured and displayed.

  3. Improvement of the thermo-mechanical position stability of the beam position monitor in the PLS-II

    NASA Astrophysics Data System (ADS)

    Ha, Taekyun; Hong, Mansu; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-09-01

    In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.

  4. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    PubMed

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  5. Effects of rhythmical and extra-rhythmical qualities of music on heart rate during stationary bike activities.

    PubMed

    DI Cagno, Alessandra; Iuliano, Enzo; Fiorilli, Giovanni; Aquino, Giovanna; Giombini, Arrigo; Menotti, Federica; Tsopani, Despina; Calcagno, Giuseppe

    2016-10-01

    The aim of this study was to evaluate the effects of rhythmical and extra-rhythmical qualities of music on the heart rate (HR) and rates of perceived exertion (RPE), during sub-maximal stationary bike activity. HR of 28 female adult participants was monitored during 3 session of physical activity, performed under 3 different conditions: Hi-BPM (music with 150-170 BPM), RHYTHM (rhythmical qualities only of Hi-BPM condition) and control condition without music (CONTROL). Four parameters were analyzed: the highest HR value (High-HR), High-HR minus starting HR (∆HR), time to reach the 75% of Maximal HR (MHR) (TimeTo75%) and time over 75% MHR (TimeOver75%). HR trend analysis was performed to evaluate differences among the three conditions. OMNI-Cycle Scale was administered to evaluate RPE. MANOVA showed significant differences between the three conditions in TimeTo75%, ∆HR (P<0.01) and TimeOver75% (P<0.05). In RHYTHM and CONTROL conditions after reaching 75% MHR, the HR increase were significantly lower than Hi-BPM (P<0.01). No significant differences were found in OMNI-Cycle Scale scores of Hi-BPM and RHYTHM whereas RPE was significantly higher in CONTROL condition (P<0.05). Hi-BPM and RHYTHM music allowed a faster reaching of the aerobic training zone compared to CONTROL conditions. Nevertheless, after 75% MHR, extra-rhythmical qualities are necessary to maintain or to increase the working HR levels.

  6. DEVS Unified Process for Web-Centric Development and Testing of System of Systems

    DTIC Science & Technology

    2008-05-20

    gathering from the user. Further, methodologies have been developed to generate DEVS models from BPMN /BPEL-based and message-based requirement specifications...27] 3. BPMN /BPEL based system specifications: Business Process Modeling Notation ( BPMN ) [bpm] or Business Process Execution Language (BPEL) provide a...information is stored in .wsdl and .bpel files for BPEL but in proprietary format for BPMN . 4. DoDAF-based requirement specifications: Department of

  7. Adherence to optimal heart rate control in heart failure with reduced ejection fraction: insight from a survey of heart rate in heart failure in Sweden (HR-HF study).

    PubMed

    Fu, M; Ahrenmark, U; Berglund, S; Lindholm, C J; Lehto, A; Broberg, A Månsson; Tasevska-Dinevska, G; Wikstrom, G; Ågard, A; Andersson, B

    2017-12-01

    Despite that heart rate (HR) control is one of the guideline-recommended treatment goals for heart failure (HF) patients, implementation has been painstakingly slow. Therefore, it would be important to identify patients who have not yet achieved their target heart rates and assess possible underlying reasons as to why the target rates are not met. The survey of HR in patients with HF in Sweden (HR-HF survey) is an investigator-initiated, prospective, multicenter, observational longitudinal study designed to investigate the state of the art in the control of HR in HF and to explore potential underlying mechanisms for suboptimal HR control with focus on awareness of and adherence to guidelines for HR control among physicians who focus on the contributing role of beta-blockers (BBs). In 734 HF patients the mean HR was 68 ± 12 beats per minute (bpm) (37.2% of the patients had a HR >70 bpm). Patients with HF with reduced ejection fraction (HFrEF) (n = 425) had the highest HR (70 ± 13 bpm, with 42% >70 bpm), followed by HF with preserved ejection fraction and HF with mid-range ejection fraction. Atrial fibrillation, irrespective of HF type, had higher HR than sinus rhythm. A similar pattern was observed with BB treatment. Moreover, non-achievement of the recommended target HR (<70 bpm) in HFrEF and sinus rhythm was unrelated to age, sex, cardiovascular risk factors, cardiovascular diseases, and comorbidities, but was related to EF and the clinical decision of the physician. Approximately 50% of the physicians considered a HR of >70 bpm optimal and an equal number considered a HR of >70 bpm too high, but without recommending further action. Furthermore, suboptimal HR control cannot be attributed to the use of BBs because there was neither a difference in use of BBs nor an interaction with BBs for HR >70 bpm compared with HR <70 bpm. Suboptimal control of HR was noted in HFrEF with sinus rhythm, which appeared to be attributable to physician decision making rather than to the use of BBs. Therefore, our results underline the need for greater attention to HR control in patients with HFrEF and sinus rhythm and thus a potential for improved HF care.

  8. BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G.M.; Shaftan; T.

    2011-03-28

    Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used tomore » measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.« less

  9. Event-synchronized data acquisition system for the SPring-8 linac beam position monitors

    NASA Astrophysics Data System (ADS)

    Masuda, T.; Fukui, T.; Tanaka, R.; Taniuchi, T.; Yamashita, A.; Yanagida, K.

    2005-05-01

    By the summer of 2003, we had completed the installation of a new non-destructive beam position monitor (BPM) system to facilitate beam trajectory and energy correction for the SPring-8 linac. In all, 47 BPM sets were installed on the 1-GeV linac and three beam-transport lines. All of the BPM data acquisition system was required to operate synchronously with the electron beam acceleration cycle. We have developed an event-synchronized data acquisition system for the BPM data readout. We have succeeded in continuously taking all the BPMs data from six VME computers synchronized with the 10 pps operation of the linac to continuously acquire data. For each beam shot, the data points are indexed by event number and stored in a database. Using the real-time features of the Solaris operating system and distributed database technology, we currently have achieved about 99.9% efficiency in capturing and archiving all of the 10 Hz data. The linac BPM data is available for off-line analysis of the beam trajectory, but also for real-time control and automatic correction of the beam trajectory and energy.

  10. APPLICATION OF NEURAL NETWORK ALGORITHMS FOR BPM LINEARIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musson, John C.; Seaton, Chad; Spata, Mike F.

    2012-11-01

    Stripline BPM sensors contain inherent non-linearities, as a result of field distortions from the pickup elements. Many methods have been devised to facilitate corrections, often employing polynomial fitting. The cost of computation makes real-time correction difficult, particulalry when integer math is utilized. The application of neural-network technology, particularly the multi-layer perceptron algorithm, is proposed as an efficient alternative for electrode linearization. A process of supervised learning is initially used to determine the weighting coefficients, which are subsequently applied to the incoming electrode data. A non-linear layer, known as an activation layer, is responsible for the removal of saturation effects. Implementationmore » of a perceptron in an FPGA-based software-defined radio (SDR) is presented, along with performance comparisons. In addition, efficient calculation of the sigmoidal activation function via the CORDIC algorithm is presented.« less

  11. [Successful outcome of a pregnancy with an extremely low fetal heart rate (34 bpm) due to isolated complete heart block--case report].

    PubMed

    Hamela-Olkowska, Anita; Dangel, Joanna; Miszczak-Knecht, Maria

    2009-09-01

    Isolated complete congenital heart block (CHB) in the majority of cases is associated with the presence of autoantibodies to SSA (Ro) and SSB (La) antigens in the maternal serum. The prognosis is less favorable in fetuses with a ventricular rate < 55bpm. We have reported a case of a fetus with an isolated non-autoimmune CHB with an extremely low ventricular rate (34bpm) in which the outcome was favorable. In the neonate the non-compaction of the myocardium was diagnosed.

  12. Utilizing the N beam position monitor method for turn-by-turn optics measurements

    NASA Astrophysics Data System (ADS)

    Langner, A.; Benedetti, G.; Carlà, M.; Iriso, U.; Martí, Z.; de Portugal, J. Coello; Tomás, R.

    2016-09-01

    The N beam position monitor method (N -BPM) which was recently developed for the LHC has significantly improved the precision of optics measurements that are based on BPM turn-by-turn data. The main improvement is due to the consideration of correlations for statistical and systematic error sources, as well as increasing the amount of BPM combinations which are used to derive the β -function at one location. We present how this technique can be applied at light sources like ALBA, and compare the results with other methods.

  13. An approach to define semantics for BPM systems interoperability

    NASA Astrophysics Data System (ADS)

    Rico, Mariela; Caliusco, María Laura; Chiotti, Omar; Rosa Galli, María

    2015-04-01

    This article proposes defining semantics for Business Process Management systems interoperability through the ontology of Electronic Business Documents (EBD) used to interchange the information required to perform cross-organizational processes. The semantic model generated allows aligning enterprise's business processes to support cross-organizational processes by matching the business ontology of each business partner with the EBD ontology. The result is a flexible software architecture that allows dynamically defining cross-organizational business processes by reusing the EBD ontology. For developing the semantic model, a method is presented, which is based on a strategy for discovering entity features whose interpretation depends on the context, and representing them for enriching the ontology. The proposed method complements ontology learning techniques that can not infer semantic features not represented in data sources. In order to improve the representation of these entity features, the method proposes using widely accepted ontologies, for representing time entities and relations, physical quantities, measurement units, official country names, and currencies and funds, among others. When the ontologies reuse is not possible, the method proposes identifying whether that feature is simple or complex, and defines a strategy to be followed. An empirical validation of the approach has been performed through a case study.

  14. Differences Among a Modern Cohort of BRCA Mutation Carriers Choosing Bilateral Prophylactic Mastectomies Compared to Breast Surveillance.

    PubMed

    Gilbert, Elizabeth; Zabor, Emily C; Stempel, Michelle; Mangino, Debra; Heerdt, Alexandra; Pilewskie, Melissa

    2017-10-01

    Women with a BRCA mutation have significantly elevated breast cancer risk, which can be reduced by >90% with bilateral prophylactic mastectomy (BPM). We sought to compare a cohort of BRCA mutation carriers choosing BPM versus breast surveillance to better elucidate factors that may impact decision making. Women with a BRCA mutation were retrospectively identified from a prospectively maintained database. The surveillance cohort (n = 313) consisted of women seen in a high-risk clinic between 2014 and 2016, while the surgery cohort (n = 142) consisted of women who underwent BPM between 2010 and 2016. Clinical and familial factors were compared between the groups. Women choosing BPM were more likely to have a BRCA1 than BRCA2 mutation compared with the surveillance group (57 vs. 45%, p = 0.02) and were less likely to have a personal history of ovarian cancer (10 vs. 20%, p = 0.01). Furthermore, women undergoing BPM were more likely to be married (78 vs. 62%, p = 0.01), to have more children (median 2 vs. 1, p < 0.001), and to have undergone a prophylactic oophorectomy (61 vs. 37%, p < 0.001). Women choosing BPM had more first-degree relatives (63 vs. 48%, p = 0.01) or a sister (23 vs. 14%, p = 0.02) with a history of breast cancer and were more likely to have a family member with ovarian cancer under the age of 40 years (9 vs. 4%, p = 0.03). There was no difference in the number of prior breast biopsies or history of atypia/lobular carcinoma in situ. The decision to undergo BPM appears multifactorial, with gene mutation, family history, and relationships appearing to have the strongest influence on decision making.

  15. Heart Rate Dependency of Large Artery Stiffness.

    PubMed

    Tan, Isabella; Spronck, Bart; Kiat, Hosen; Barin, Edward; Reesink, Koen D; Delhaas, Tammo; Avolio, Alberto P; Butlin, Mark

    2016-07-01

    Carotid-femoral pulse wave velocity (cfPWV) quantifies large artery stiffness, it is used in hemodynamic research and is considered a useful cardiovascular clinical marker. cfPWV is blood pressure (BP) dependent. Intrinsic heart rate (HR) dependency of cfPWV is unknown because increasing HR is commonly accompanied by increasing BP. This study aims to quantify cfPWV dependency on acute, sympathovagal-independent changes in HR, independent of BP. Individuals (n=52, age 40-93 years, 11 female) with in situ cardiac pacemakers or cardioverter defibrillators were paced at 60, 70, 80, 90, and 100 bpm. BP and cfPWV were measured at each HR. Both cfPWV (mean [95% CI], 0.31 [0.26-0.37] m/s per 10 bpm; P<0.001) and central aortic diastolic pressure (3.78 [3.40-4.17] mm Hg/10 bpm; P<0.001) increased with HR. The HR effect on cfPWV was isolated by correcting the BP effects by 3 different methods: (1) statistically, by a linear mixed model; (2) mathematically, using an exponential relationship between BP and cross-sectional lumen area; and (3) using measured BP dependency of cfPWV derived from changes in BP induced by orthostatic changes (seated and supine) in a subset of subjects (n=17). The BP-independent effects of HR on cfPWV were quantified as 0.20 [0.11-0.28] m/s per 10 bpm (P<0.001, method 1), 0.16 [0.11-0.22] m/s per 10 bpm (P<0.001, method 2), and 0.16 [0.11-0.21] m/s per 10 bpm (P<0.001, method 3). With a mean HR dependency in the range of 0.16 to 0.20 m/s per 10 bpm, cfPWV may be considered to have minimal physiologically relevant changes for small changes in HR, but larger differences in HR must be considered as contributing to significant differences in cfPWV. © 2016 American Heart Association, Inc.

  16. Heart rate is a prognostic risk factor for myocardial infarction: a post hoc analysis in the PERFORM (Prevention of cerebrovascular and cardiovascular Events of ischemic origin with teRutroban in patients with a history oF ischemic strOke or tRansient ischeMic attack) study population.

    PubMed

    Fox, Kim; Bousser, Marie-Germaine; Amarenco, Pierre; Chamorro, Angel; Fisher, Marc; Ford, Ian; Hennerici, Michael G; Mattle, Heinrich P; Rothwell, Peter M

    2013-10-09

    Elevated resting heart rate is known to be detrimental to morbidity and mortality in cardiovascular disease, though its effect in patients with ischemic stroke is unclear. We analyzed the effect of baseline resting heart rate on myocardial infarction (MI) in patients with a recent noncardioembolic cerebral ischemic event participating in PERFORM. We compared fatal or nonfatal MI using adjusted Cox proportional hazards models for PERFORM patients with baseline heart rate <70 bpm (n=8178) or ≥70 bpm (n=10,802). In addition, heart rate was analyzed as a continuous variable. Other cerebrovascular and cardiovascular outcomes were also explored. Heart rate ≥70 bpm was associated with increased relative risk for fatal or nonfatal MI (HR 1.32, 95% CI 1.03-1.69, P=0.029). For every 5-bpm increase in heart rate, there was an increase in relative risk for fatal and nonfatal MI (11.3%, P=0.0002). Heart rate ≥70 bpm was also associated with increased relative risk for a composite of fatal or nonfatal ischemic stroke, fatal or nonfatal MI, or other vascular death (excluding hemorrhagic death) (P<0001); vascular death (P<0001); all-cause mortality (P<0001); and fatal or nonfatal stroke (P=0.04). For every 5-bpm increase in heart rate, there were increases in relative risk for fatal or nonfatal ischemic stroke, fatal or nonfatal MI, or other vascular death (4.7%, P<0.0001), vascular death (11.0%, P<0.0001), all-cause mortality (8.0%, P<0.0001), and fatal and nonfatal stroke (2.4%, P=0.057). Elevated heart rate ≥70 bpm places patients with a noncardioembolic cerebral ischemic event at increased risk for MI. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Tannate complexes of antihistaminic drug: sustained release and taste masking approaches.

    PubMed

    Rahman, Ziyaur; Zidan, Ahmed S; Berendt, Robert T; Khan, Mansoor A

    2012-01-17

    The aim of this investigation was to evaluate the complexation potential of brompheniramine maleate (BPM) and tannic acid (TA) for sustained release and taste masking effects. The complexes (1:1-1:7 TA to BPM ratio) were prepared by the solvent evaporation method using methanol, phosphate buffer pH 6.8 or 0.1N HCl as common solvents. The complexes were characterized microscopically by scanning electron microscopy (SEM), chemically by Fourier transform infrared (FTIR) and solid-state NMR (SSNMR), thermally by differential scanning calorimetry (DSC), for crystallinity by powder X-ray powder diffraction (PXRD), for organoleptic evaluation by electronic tongue (e-tongue), and for solubility in 0.1N HCl and phosphate buffer pH 6.8. The dissolution studies were carried out using the USP II method at 50 rpm in 500 ml of dissolution media (0.1N HCl or phosphate buffer pH 6.8). SEM images revealed that the morphology of complexes were completely different from the individual components, and all complexes had the same morphological characteristics, irrespective of the solvent used for their preparation, pH or ratio of BPM and TA. The FTIR spectra showed the presence of chemical interactions between the TA and BPM. DSC, PXRD and SSNMR indicated that the drug lost its crystalline nature by formation of the complex. Complexation has significantly reduced the solubility of BPM and sustained the drug release up to 24h in phosphate buffer pH 6.8 media. The bitter taste of the BPM was completely masked which was indicated by Euclidean distance values which was far from the drug but near to its placebo in the complexes in all ratios studied. The taste masked complexes can be potentially developed as suitable dosage forms for pediatric use. In summary, complexation of BPM and TA effectively sustained the dissolution and masked the bitter taste of drug for the development of suitable dosage forms for pediatric use. Published by Elsevier B.V.

  18. Comparing the Effects of Rest and Massage on Return to Homeostasis Following Submaximal Aerobic Exercise: a Case Study

    PubMed Central

    Resnick, Portia B.

    2016-01-01

    Introduction Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject’s heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. Methods One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Results Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. Conclusions No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session. PMID:26977215

  19. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff R.; Biscardi, C.; Cerniglia, P.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less

  20. Optimization of pharmacotherapy in chronic heart failure: is heart rate adequately addressed?

    PubMed

    Franke, Jennifer; Wolter, Jan Sebastian; Meme, Lillian; Keppler, Jeannette; Tschierschke, Ramon; Katus, Hugo A; Zugck, Christian

    2013-01-01

    The aim of the study is to evaluate the use of beta-blockers in chronic heart failure (CHF) and the extent of heart rate reduction achieved in clinical practice and to determine differences in outcome of patients who fulfilled select inclusion criteria of the SHIFT study according to resting heart rate modulated by beta-blocker therapy. We evaluated an all-comer population of our dedicated CHF outpatient clinic between 2006 and 2010. For inclusion, individually optimized doses of guideline-recommended pharmacotherapy including beta-blockers had to be maintained for at least 3 months and routine follow-up performed at our outpatient CHF-clinic thereafter. Treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate were assessed. The outcome of patients who fulfilled select inclusion criteria of the SHIFT study (left-ventricular ejection fraction (LVEF) ≤35 %, sinus rhythm, NYHA II-IV) and were followed-up for at least 1 year was stratified according to resting heart rates: ≥75 versus <75 bpm and ≥70 versus <70 bpm. The composite primary endpoint was defined as all-cause death or hospital admission for worsening heart failure during 12-month follow-up. In total, 3,181 patients were assessed in regard to treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate. Of the overall studied population, 443 patients fulfilled all inclusion criteria and entered outcome analysis. Median observation time of survivors was 27.5 months with 1,039.7 observation-years in total. Up-titration to at least half the evidence-based target dose of beta-blockers was achieved in 69 % and full up-titration in 29 % of these patients. Patients with increased heart rates were younger, more often male, exhibited a higher NYHA functional class and lower LVEF. The primary endpoint occurred in 21 % of patients in the ≥70 bpm group versus 9 % of patients in the group with heart rates <70 bpm (p <0.01). Likewise, comparing the groups ≥75 and <75 bpm, the primary endpoint was significantly increased in the group of patients with heart rates ≥75 bpm 27 vs. 12.2 %; p < 0.01). 5-year event-free survival was significantly lower among patients with heart rates ≥70 bpm as compared to those with <70 bpm (log-rank test p < 0.05) and among patients in the ≥75 bpm group versus <75 bpm group (log-rank test p < 0.01). In conclusion, in clinical practice, 53 % of CHF patients have inadequate heart rate control (heart rates ≥75 bpm) despite concomitant beta-blocker therapy. In this non-randomized cohort, adequate heart rate control under individually optimized beta-blocker therapy was associated with improved mid- and long-term clinical outcome up to 5 years. As further up titration of beta-blockers is not achievable in many patients, the administration of a selective heart rate lowering agent, such as ivabradine adjuvant to beta-blockers may pose an opportunity to further modulate outcome.

  1. Metal-Organic Frameworks of Pyrazolate Derivatives: Synthesis and Applications for Chemical Sensing, Gas Separation, and Catalysis

    NASA Astrophysics Data System (ADS)

    Kivi, Charlie Eric William

    In this work we examine the structure and applications of metal-organic frameworks (MOFs) synthesized from pyrazolate derivatives. In total, six pyrazolate ligands were examined: 4-(4-(3,5-dimethyl-1H-pyrazol-4-yl)phenyl)pyridine (HL), 1,1'-methylenebis(3,5-dimethyl-1H-pyrazolyl-4-carboxylic acid) (H2BPM), triethyl-1,1',1''-methanetriyltris(3,5-dimethyl-1H-pyrazole-4-carboxylate) (TPM-1), triethyl-4,4',4''-(methanetriyltris[3,5-dimethyl-1H-pyrazole-1,4-diyl])tribenzoate (TPM-2), 1,1',1'',1'''-(propane-1,1,3,3-tetrayl)tetrakis(3,5-dimethyl-1H-pyrazole-4-carboxylic acid) (H4TPP), tetraethyl-1,1',1'',1'''-(1,4-phenylenebis[methanetriyl]) tetrakis(3,5-dimethyl-1H-pyrazole-4-carboxylate)pyridinephenylpyrazole ( TPX). These ligands were used to synthesize a variety of MOFs that were subsequently investigated for luminescent sensing, gas storage, and catalytic performance. In Chapter 2, three MOFs synthesized from the reaction of HL and CuX (X = Br, I) were investigated. These materials were found to form MOFs which contained the luminescent trinuclear Cu(I) pyrazolate unit. Only CuBr and HL alone resulted in a MOF of sufficient purity and stability to permit evaluation as a luminescent sensor. Experiments with various volatile organic compounds revealed turn-on (luminescence enhancement) behaviour for ethyl acetate, pentane, and benzene and turn-off (luminescence quenching) behaviour for diethyl ether and chloroform for this material. In Chapters 3 and 4, ten MOFs are described. These were synthesized from H2BPM and metal-acetate salts. Chapter 3 encompassed two MOFs: [Ni(BPM)]n·xDMSO and [Cd(BPM)]n·xDMSO. These MOFs are isostructural, microporous materials. Evacuation of the pores led to collapse of the [Cd(BPM)]n·xDMSO material but [Ni(BPM)]n·xDMSO proved to be permanently porous. Further investigations revealed [Ni(BPM)] n·xDMSO selectively adsorbed methane over nitrogen indicating it may serve as a porous material for coal mine methane capture. Chapter 4 investigated the many other structures H2BPM can assume in the presence of manganese, cobalt, iron, copper, and europium. Cobalt in particular proved highly tunable with 4 separate structures being synthesized such as [Co2(BPM)2(H2 O)4(Bpy)0.5]n·2DMF·2(H 2O). This was achieved through varying the synthetic conditions. [Co 2(BPM)2(H2O)4(Bpy) 0.5]n·2DMF·2(H2O)and [Eu( BPM)(OAc)]n were further investigated for the oxidation of olefins and luminescence respectively. In Chapter 5, metal complexes Mo(TPM-1)(CO)3, Mo(TPM-2)(CO)3, Pd2(H4TPP )Cl4, and Pd2(TPX)Cl4 were synthesized. The catalytic performance of Mo(TPM-1)(CO) 3 was evaluated and found to be effective for the oxidation of olefins. MOF synthesis was attempted with all four compounds but was ultimately unsuccessful. Although one MOF was produced from Mo(TPM-1)(CO)3, large scale synthesis was not possible preventing full investigation of its properties.

  2. Differential Resting-State Functional Connectivity of Striatal Subregions in Bipolar Depression and Hypomania

    PubMed Central

    Altinay, Murat I.; Hulvershorn, Leslie A.; Karne, Harish; Beall, Erik B.

    2016-01-01

    Abstract Bipolar disorder (BP) is characterized by periods of depression (BPD) and (hypo)mania (BPM), but the underlying state-related brain circuit abnormalities are not fully understood. Striatal functional activation and connectivity abnormalities have been noted in BP, but consistent findings have not been reported. To further elucidate striatal abnormalities in different BP states, this study investigated differences in resting-state functional connectivity of six striatal subregions in BPD, BPM, and healthy control (HC) subjects. Ninety medication-free subjects (30 BPD, 30 BPM, and 30 HC), closely matched for age and gender, were scanned using 3T functional magnetic resonance imaging (fMRI) acquired at resting state. Correlations of low-frequency blood oxygen level dependent signal fluctuations for six previously described striatal subregions were used to obtain connectivity maps of each subregion. Using a factorial design, main effects for differences between groups were obtained and post hoc pairwise group comparisons performed. BPD showed increased connectivity of the dorsal caudal putamen with somatosensory areas such as the insula and temporal gyrus. BPM group showed unique increased connectivity between left dorsal caudate and midbrain regions, as well as increased connectivity between ventral striatum inferior and thalamus. In addition, both BPD and BPM exhibited widespread functional connectivity abnormalities between striatal subregions and frontal cortices, limbic regions, and midbrain structures. In summary, BPD exhibited connectivity abnormalities of associative and somatosensory subregions of the putamen, while BPM exhibited connectivity abnormalities of associative and limbic caudate. Most other striatal subregion connectivity abnormalities were common to both groups and may be trait related. PMID:26824737

  3. Preoperative risk assessment among women undergoing bilateral prophylactic mastectomy for cancer risk reduction.

    PubMed

    Rueth, Natasha M; McMahon, Melissa; Arrington, Amanda K; Swenson, Karen; Leach, Joseph; Tuttle, Todd M

    2011-09-01

    Cancer risk assessment is an important decision-making tool for women considering irreversible risk-reducing surgery. Our objective was to determine the prevalence of BRCA testing among women undergoing bilateral prophylactic mastectomy (BPM) and to review the characteristics of women who choose BPM within a metropolitan setting. We retrospectively reviewed records of women who underwent BPM in the absence of cancer within 2 health care systems that included 5 metropolitan hospitals. Women with invasive carcinoma or ductal carcinoma in situ (DCIS) were excluded; neither lobular carcinoma in situ (LCIS) nor atypical hyperplasia (AH) were exclusion criteria. We collected demographic information and preoperative screening and risk assessment, BRCA testing, reconstruction, and associated cancer risk-reducing surgery data. We compared women who underwent BRCA testing to those not tested. From January 2002 to July 2009, a total of 71 BPMs were performed. Only 25 women (35.2%) had preoperative BRCA testing; 88% had a BRCA mutation. Compared with tested women, BRCA nontested women were significantly older (39.1 vs. 49.2 years, P < 0.001), had significantly more preoperative biopsies and mammograms and had fewer previous or simultaneous cancer risk-reducing surgery (oophorectomy). Among BRCA nontested women, common indications for BPM were family history of breast cancer (n = 21, 45.6%) or LCIS or AH (n = 16, 34.8%); 9 nontested women (19.6%) chose BPM based on exclusively on cancer-risk anxiety or personal preference. Most women who underwent BPM did not receive preoperative genetic testing. Further studies are needed to corroborate our findings in other geographic regions and practice settings.

  4. Heart rate differentiates urgency and emergency in hypertensive crisis.

    PubMed

    Al Bannay, Rashed; Böhm, Michael; Husain, Aysha

    2013-08-01

    To study the clinical significance of presenting blood pressure parameters and heart rate in patients with hypertensive crisis. In patients admitted with hypertensive crisis between January 2011 and May 2011, demography, mode of presentation, co-morbidities, blood pressure readings, and heart rate at presentation were documented. Further clustering of hypertensive crisis into emergency or urgency was based on the presence or absence of target organ involvement. The relationship between blood pressure parameters, heart rate, and other variables was analyzed. 189 patients in sinus rhythm were enrolled in this pilot study. The rate of hypertensive urgency was 56 %, whereas the rate of hypertensive emergency was 44 %, respectively. Subjects with hypertensive emergency had a higher mean heart rate (93 ± 22.7 bpm) than those with urgency (81 ± 11.5 bpm) (P = 0.015). Women had higher heart rates (92 ± 18.5 bpm) than men (86 ± 17.6 bpm) (P = 0.014). Heart rates below 100 bpm had a specificity of 94 %, classifying patients as hypertensive urgency. Tachycardia had a powerful statistical association with hypertensive left ventricular failure (P < 0.0001). Other hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, pulse pressure, and mean blood pressure relates neither to urgency nor to emergency. Diabetic patients with HBA1c levels of more than 53 mmol/mol had a heart rate of more than 100 bpm (P = 0.015) during hypertensive crisis. Normal heart rate is characteristic of hypertensive urgency. Tachycardia in this setting is an ominous sign and denotes hypertensive complications in particular left ventricular failure. Among diabetics, elevated heart rate is associated with poor glycemic control.

  5. Patients' perspectives and experiences concerning barriers to accessing information about bilateral prophylactic mastectomy.

    PubMed

    Glassey, Rachael; O'Connor, Moira; Ives, Angela; Saunders, Christobel; kConFab Investigators; O'Sullivan, Sarah; Hardcastle, Sarah J

    2018-05-11

    To explore the barriers and experiences of accessing information for women who have received genetic risk assessment/testing results for breast cancer (BC) and are considering a bilateral prophylactic mastectomy (BPM) and, exploring participants' preferences concerning information and support needs. A qualitative retrospective study guided by interpretative phenomenological analysis was utilised. Semi-structured interviews were conducted with forty-six women who were either considering BPM or had already undergone the surgery. Three themes identified barriers to accessing information; difficulties accessing information, inconsistent information and clinical focus/medicalized information. A fourth theme - preferences of information and support needs, identified three subthemes; these were, psychological support, clearly defined processes and photos of mastectomies/reconstruction surgeries. Barriers to accessing information appeared to be widespread. A lack of integrated services contributed to inconsistent information, and medicalized terminology/clinical focus of consultations further complicated understanding. Preferences for information include clearly defined processes, so women know the pathways after confirmation of familial BC risk. Clinical implications include a multidisciplinary team approach, and a protocol that reflects current practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Coupled optics reconstruction from TBT data using MAD-X

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexahin, Y.; Gianfelice-Wendt, E.; /Fermilab

    2007-06-01

    Turn-by-turn BPM data provide immediate information on the coupled optics functions at BPM locations. In the case of small deviations from the known (design) uncoupled optics some cognizance of the sources of perturbation, BPM calibration errors and tilts can also be inferred without detailed lattice modeling. In practical situations, however, fitting the lattice model with the help of some optics code would lead to more reliable results. We present an algorithm for coupled optics reconstruction from TBT data on the basis of MAD-X and give examples of its application for the Fermilab Tevatron accelerator.

  7. Performance Evaluation of LDPC Coding and Iterative Decoding System in BPM R/W Channel Affected by Head Field Gradient, Media SFD and Demagnetization Field

    NASA Astrophysics Data System (ADS)

    Nakamura, Yasuaki; Okamoto, Yoshihiro; Osawa, Hisashi; Aoi, Hajime; Muraoka, Hiroaki

    We evaluate the performance of the write-margin for the low-density parity-check (LDPC) coding and iterative decoding system in the bit-patterned media (BPM) R/W channel affected by the write-head field gradient, the media switching field distribution (SFD), the demagnetization field from adjacent islands and the island position deviation. It is clarified that the LDPC coding and iterative decoding system in R/W channel using BPM at 3 Tbit/inch2 has a write-margin of about 20%.

  8. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  9. Extracellular matrices for gastrointestinal surgery: Ex vivo testing and current applications

    PubMed Central

    Hoeppner, Jens; Marjanovic, Goran; Helwig, Peter; Hopt, Ulrich Theodor; Keck, Tobias

    2010-01-01

    AIM: To assess the effects of bile and pancreatic juice on structural and mechanical resistance of extracellular matrices (ECMs) in vitro. METHODS: Small-intestinal submucosa (SIS), porcine dermal matrix (PDM), porcine pericardial matrix (PPM) and bovine pericardial matrix (BPM) were incubated in human bile and pancreatic juice in vitro. ECMs were examined by macroscopic observation, scanning electron microscopy (SEM) and testing of mechanical resistance. RESULTS: PDM dissolved within 4 d after exposure to bile or pancreatic juice. SIS, PPM and PDM retained their integrity for > 60 d when incubated in either digestive juice. The effect of bile was found to be far more detrimental to mechanical stability than pancreatic juice in all tested materials. In SIS, the loss of mechanical stability after incubation in either of the digestive secretions was less distinct than in PPM and BPM [mFmax 4.01/14.27 N (SIS) vs 2.08/5.23 N (PPM) vs 1.48/7.89 N (BPM)]. In SIS, the extent of structural damage revealed by SEM was more evident in bile than in pancreatic juice. In PPM and BPM, structural damage was comparable in both media. CONCLUSION: PDM is less suitable for support of gastrointestinal healing. Besides SIS, PPM and BPM should also be evaluated experimentally for gastrointestinal indications. PMID:20731016

  10. Effect of varying heart rate on intra-ventricular filling fluid dynamics

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Okafor, Ikechukwu; Angirish, Yagna; Yoganathan, Ajit

    2013-11-01

    Impaired exercise tolerance is used to delineate asymptomatic patients during the clinical diagnosis of diastolic left heart failure. Examining the effects of varying heart rate on intra-ventricular filling can provide a physical understanding of the specific flow characteristics that are impacted during exercise. In this study, diastolic filling was investigated with an anatomical left ventricle (LV) physical model under normal heart rate of 70 bpm, and varying exercise conditions of 100 bpm and 120 bpm. The LV model was incorporated into a flow loop and tuned for physiological inflow rates and outflow pressures. 2D PIV measurements were conducted along 3 parallel longitudinal planes. The systemic pressure was maintained the same across all test conditions. The E/A ratio was maintained within 1.0-1.2 across all heart rates. The strength of the mitral vortex ring formed during E-wave, as well as the peak incoming jet velocity, decreased with increasing heart rate. During peak flow of the A-wave, the vortex ring propagated farther into the LV for 120 bpm as compared to 70 bpm. The results point to the heightened role of the atrial kick for optimal LV filling during exercise conditions. This study was funded by a grant from the National Heart, Lung and Blood Institute (RO1HL70262).

  11. Ligand effects on the structure and magnetic properties of alternating copper(II) chains with 2,2'-bipyrimidine- and polymethyl-substituted pyrazolates as bridging ligands.

    PubMed

    Castro, Isabel; Calatayud, M Luisa; Barros, Wdeson P; Carranza, José; Julve, Miguel; Lloret, Francesc; Marino, Nadia; De Munno, Giovanni

    2014-06-02

    A novel series of heteroleptic copper(II) compounds of formulas {[Cu2(μ-H2O)(μ-pz)2(μ-bpm)(ClO4)(H2O)]ClO4·2H2O}n (1), {[Cu2(μ-H2O)(μ-3-Mepz)2(μ-bpm)](ClO4)2·2H2O}n (2), and {[Cu2(μ-OH)(μ-3,5-Me2pz)(μ-bpm)(H-3,5-Me2pz)2](ClO4)2}n (3) [bpm = 2,2'-bipyrimidine, Hpz = pyrazole, H-3-Mepz = 3-methylpyrazole, and H-3,5-Me2pz = 3,5-dimethylpyrazole] have been synthesized and structurally characterized by X-ray diffraction methods. The crystal structures of 1 and 2 consist of copper(II) chains with regular alternating bpm and bis(pyrazolate)(aqua) bridges, whereas that of 3 is made up of copper(II) chains with regular alternating bpm and (pyrazolate)(hydroxo) bridges. The copper centers are six- (1) or five-coordinate (2) in axially elongated, octahedral (1) or square-pyramidal (2) environments in 1 and 2, whereas they are five-coordinate in distorted trigonal-bipyramidal surroundings in 3. The values of the copper-copper separations across the bpm/pyrazolate bridges are 5.5442(7)/3.3131(6) (1), 5.538(1)/3.235(1) (2), and 5.7673(7)/3.3220(6) Å (3). The magnetic properties of 1-3 have been investigated in the temperature range of 25-300 K. The analysis of their magnetic susceptibility data through the isotropic Hamiltonian for an alternating antiferromagnetic copper(II) chain model [H = -J∑i=1-n/2 (S2i·S2i-1 + αS2i·S2i+1), with α = J'/J and Si = SCu = 1/2] reveals the presence of a strong to moderate antiferromagnetic coupling through the bis(pyrazolate)(aqua) [-J = 217 (1) and 215 cm(-1) (2)] and (pyrazolate)(hydroxo) bridges [-J = 153 cm(-1) (3)], respectively, whereas a strong to weak antiferromagnetic coupling occurs through the bis-bidentate bpm [-J' = 211 (1), 213 (2), and 44 cm(-1) (3)]. A simple orbital analysis of the magnetic exchange interaction within the bpm- and pyrazolate-bridged dicopper(II) fragments of 1-3 visualizes the σ-type pathways involving the (dx(2)-y(2)) (1 and 2) or d(z(2)) (3) magnetic orbitals on each metal ion, which account for the variation of the magnetic properties in these three novel examples of one-dimensional copper(II) compounds with regular alternating intrachain antiferromagnetic interactions.

  12. Energy expenditure and heart rate response to breaking up sedentary time with three different physical activity interventions.

    PubMed

    Carter, S E; Jones, M; Gladwell, V F

    2015-05-01

    Prolonged sedentary behaviour is associated with increased cardiovascular disease risk and decreased energy expenditure (EE). Workplace interventions breaking up sedentary time have increased EE but the cardiovascular responses are unknown. The practicalities of these interventions, such as required costs and workplace adaptations, are questioned. Calisthenics exercises overcome such limitations, but have not been assessed. The aim of this study was to assess the EE and heart rate (HR) response when breaking up sedentary time with a short bout of standing, walking or calisthenics. Twenty healthy participants (15 male) completed four 30 min conditions: a) 30 min sitting, or breaking up this period with two minutes of b) standing, c) treadmill walking (4 km·h(-1)) or d) a set of calisthenics exercises (including squats and lunges). HR and EE (indirect calorimetry) were assessed throughout. During the activity break, calisthenics caused the highest HR (90 ± 12 bpm) compared to all other conditions (Sit: 70 ± 12 bpm; Stand:72 ± 13 bpm; Walk:84 ± 10 bpm; p < 0.001) and EE was the highest with calisthenics (13 ± 5 kcal) compared to all conditions except walking (Sit:3 ± 1 kcal; Stand:5 ± 1 kcal; p < 0.001). The recovery following calisthenics had highest total EE (27 ± 7 kcal) compared to walking (23 ± 6 kcal) and standing (22 ± 6 kcal) and also the longest elevation of HR (p < 0.001). Calisthenics led to a greater total EE and HR response compared to standing or walking interventions. Calisthenics may be a time efficient method to break up sedentary time without individuals leaving their work environment. Hence calisthenics could be utilised to disrupt workplace sedentary time and improve cardiovascular health and assist in weight management. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Ultra-Reliable Digital Avionics (URDA) processor

    NASA Astrophysics Data System (ADS)

    Branstetter, Reagan; Ruszczyk, William; Miville, Frank

    1994-10-01

    Texas Instruments Incorporated (TI) developed the URDA processor design under contract with the U.S. Air Force Wright Laboratory and the U.S. Army Night Vision and Electro-Sensors Directorate. TI's approach couples advanced packaging solutions with advanced integrated circuit (IC) technology to provide a high-performance (200 MIPS/800 MFLOPS) modular avionics processor module for a wide range of avionics applications. TI's processor design integrates two Ada-programmable, URDA basic processor modules (BPM's) with a JIAWG-compatible PiBus and TMBus on a single F-22 common integrated processor-compatible form-factor SEM-E avionics card. A separate, high-speed (25-MWord/second 32-bit word) input/output bus is provided for sensor data. Each BPM provides a peak throughput of 100 MIPS scalar concurrent with 400-MFLOPS vector processing in a removable multichip module (MCM) mounted to a liquid-flowthrough (LFT) core and interfacing to a processor interface module printed wiring board (PWB). Commercial RISC technology coupled with TI's advanced bipolar complementary metal oxide semiconductor (BiCMOS) application specific integrated circuit (ASIC) and silicon-on-silicon packaging technologies are used to achieve the high performance in a miniaturized package. A Mips R4000-family reduced instruction set computer (RISC) processor and a TI 100-MHz BiCMOS vector coprocessor (VCP) ASIC provide, respectively, the 100 MIPS of a scalar processor throughput and 400 MFLOPS of vector processing throughput for each BPM. The TI Aladdim ASIC chipset was developed on the TI Aladdin Program under contract with the U.S. Army Communications and Electronics Command and was sponsored by the Advanced Research Projects Agency with technical direction from the U.S. Army Night Vision and Electro-Sensors Directorate.

  14. Hybrid Imaging for Extended Depth of Field Microscopy

    NASA Astrophysics Data System (ADS)

    Zahreddine, Ramzi Nicholas

    An inverse relationship exists in optical systems between the depth of field (DOF) and the minimum resolvable feature size. This trade-off is especially detrimental in high numerical aperture microscopy systems where resolution is pushed to the diffraction limit resulting in a DOF on the order of 500 nm. Many biological structures and processes of interest span over micron scales resulting in significant blurring during imaging. This thesis explores a two-step computational imaging technique known as hybrid imaging to create extended DOF (EDF) microscopy systems with minimal sacrifice in resolution. In the first step a mask is inserted at the pupil plane of the microscope to create a focus invariant system over 10 times the traditional DOF, albeit with reduced contrast. In the second step the contrast is restored via deconvolution. Several EDF pupil masks from the literature are quantitatively compared in the context of biological microscopy. From this analysis a new mask is proposed, the incoherently partitioned pupil with binary phase modulation (IPP-BPM), that combines the most advantageous properties from the literature. Total variation regularized deconvolution models are derived for the various noise conditions and detectors commonly used in biological microscopy. State of the art algorithms for efficiently solving the deconvolution problem are analyzed for speed, accuracy, and ease of use. The IPP-BPM mask is compared with the literature and shown to have the highest signal-to-noise ratio and lowest mean square error post-processing. A prototype of the IPP-BPM mask is fabricated using a combination of 3D femtosecond glass etching and standard lithography techniques. The mask is compared against theory and demonstrated in biological imaging applications.

  15. Fermilab Recycler Ring BPM Upgrade Based on Digital Receiver Technology

    NASA Astrophysics Data System (ADS)

    Webber, R.; Crisp, J.; Prieto, P.; Voy, D.; Briegel, C.; McClure, C.; West, R.; Pordes, S.; Mengel, M.

    2004-11-01

    Electronics for the 237 BPMs in the Fermilab Recycler Ring have been upgraded from a log-amplifier based system to a commercially produced digitizer-digital down converter based system. The hardware consists of a pre-amplifier connected to a split-plate BPM, an analog differential receiver-filter module and an 8-channel 80-MHz digital down converter VME board. The system produces position and intensity with a dynamic range of 30 dB and a resolution of ±10 microns. The position measurements are made on 2.5-MHz bunched beam and barrier buckets of the un-bunched beam. The digital receiver system operates in one of six different signal processing modes that include 2.5-MHz average, 2.5-MHz bunch-by-bunch, 2.5-MHz narrow band, unbunched average, un-bunched head/tail and 89-kHz narrow band. Receiver data is acquired on any of up to sixteen clock events related to Recycler beam transfers and other machine activities. Data from the digital receiver board are transferred to the front-end CPU for position and intensity computation on an on-demand basis through the VME bus. Data buffers are maintained for each of the acquisition events and support flash, closed orbit and turn-by-turn measurements. A calibration system provides evaluation of the BPM signal path and application programs.

  16. Sub-micron resolution rf cavity beam position monitor system at the SACLA XFEL facility

    NASA Astrophysics Data System (ADS)

    Maesaka, H.; Ego, H.; Inoue, S.; Matsubara, S.; Ohshima, T.; Shintake, T.; Otake, Y.

    2012-12-01

    We have developed and constructed a C-band (4.760 GHz) rf cavity beam position monitor (RF-BPM) system for the XFEL facility at SPring-8, SACLA. The demanded position resolution of the RF-BPM is less than 1 μm, because an electron beam and x-rays must be overlapped within 4 μm precision in the undulator section for sufficient FEL interaction between the electrons and x-rays. In total, 57 RF-BPMs, including IQ demodulators and high-speed waveform digitizers for signal processing, were produced and installed into SACLA. We evaluated the position resolutions of 20 RF-BPMs in the undulator section by using a 7 GeV electron beam having a 0.1 nC bunch charge. The position resolution was measured to be less than 0.6 μm, which was sufficient for the XFEL lasing in the wavelength region of 0.1 nm, or shorter.

  17. Measurements of a Newly Designed BPM for the Tevatron Electron Lens 2

    NASA Astrophysics Data System (ADS)

    Scarpine, V. E.; Kamerdzhiev, V.; Fellenz, B.; Olson, M.; Kuznetsov, G.; Kamerdzhiev, V.; Shiltsev, V. D.; Zhang, X. L.

    2006-11-01

    Fermilab has developed a second electron lens (TEL-2) for beam-beam compensation in the Tevatron as part of its Run II upgrade program. Operation of the beam position monitors (BPMs) in the first electron lens (TEL-1) showed a systematic transverse position difference between short proton bunches (2 ns sigma) and long electron pulses (˜1 us) of up to ˜1.5 mm. This difference was attributed to frequency dependence in the BPM system. The TEL-2 BPMs utilize a new, compact four-plate design with grounding strips between plates to minimize crosstalk. In-situ measurements of these new BPMs are made using a stretched wire pulsed with both proton and electron beam formats. In addition, longitudinal impedance measurements of the TEL-2 are presented. Signal processing algorithm studies indicate that the frequency-dependent transverse position offset may be reduced to ˜0.1 mm for the beam structures of interest.

  18. The correlation between fetal bradycardia area in the second stage of labor and acidemia at birth.

    PubMed

    Tranquilli, Andrea L; Biagini, Alessandra; Greco, Pantaleo; Di Tommaso, Mariarosaria; Giannubilo, Stefano R

    2013-09-01

    To quantify fetal bradycardia in the second stage of labor and to determine the threshold of the area that correlates with neonatal acidemia. We analyzed the cardiotocograms of 33 women with single pregnancy and term spontaneous labor who presented fetal bradycardia in the second stage of labor. We retrospectively calculated the fetal bradycardia area in the last 60 min before delivery with an upper limit of 90 bpm and correlated the area with neonatal pH. The study of the regression line determined the cut-off threshold between fetal well-being and distress. Significance was set at p < 0.05. The linear correlation between the bradycardia area and neonatal pH indicate that increasing bradycardia area was correlated with significant pH decrease. The threshold value of the area indicative of severe acidemia was ≥ 12.72 cm(2) (Pearson r = -0.76, p < 0.002). The diagnostic accuracy of the test was 73%. The PPV = 78.5% and the NPV = 68.4%. With such a cut-off, the timing of acidemia can be calculated as 25 min for a fetal heart rate (FHR) of 80 bpm, 13 min for a FHR of 70 bpm, 8 min for a FHR of 60 bpm, 6 min for a FHR of 50 bpm and 5 min for a FHR of 40 bpm. The bradycardia area in the second stage of labor significantly correlates with an accurate timing of fetal acidemia. Regardless of the cause of the bradycardia, the time for intervention is often short, meaning that any available intervention may be ineffective in preventing acidemia or even injury.

  19. Dopamine depletion attenuates some behavioral abnormalities in a hyperdopaminergic mouse model of bipolar disorder

    PubMed Central

    van Enkhuizen, Jordy; Geyer, Mark A.; Halberstadt, Adam L.; Zhuang, Xiaoxi; Young, Jared W.

    2014-01-01

    Background Patients with BD suffer from multifaceted symptoms, including hyperactive and psychomotor agitated behaviors. Previously, we quantified hyperactivity, increased exploration, and straighter movements of patients with BD mania in the human Behavioral Pattern Monitor (BPM). A similar BPM profile is observed in mice that are hyperdopaminergic due to reduced dopamine transporter (DAT) functioning. We hypothesized that dopamine depletion through alpha-methyl-p-tyrosine (AMPT) administration would attenuate this mania-like profile. Methods Male and female DAT wild-type (WT; n=26) and knockdown (KD; n=28) mice on a C57BL/6 background were repeatedly tested in the BPM to assess profile robustness and stability. The optimal AMPT dose was identified by treating male C57BL/6 mice (n=39) with vehicle or AMPT (10, 30, or 100 mg/kg) at 24, 20, and 4 h prior to testing in the BPM. Then, male and female DAT WT (n=40) and KD (n=37) mice were tested in the BPM after vehicle or AMPT (30 mg/kg) treatment. Results Compared to WT littermates, KD mice exhibited increased activity, exploration, straighter movement, and disorganized behavior. AMPT-treatment reduced hyperactivity and increased path organization, but potentiated specific exploration in KD mice without affecting WT mice. Limitations AMPT is not specific to dopamine and also depletes norepinephrine. Conclusions KD mice exhibit abnormal exploration in the BPM similar to patients with BD mania. AMPT-induced dopamine depletion attenuated some, but potentiated other, aspects of this mania-like profile in mice. Future studies should extend these findings into other aspects of mania to determine the suitability of AMPT as a treatment for BD mania. PMID:24287168

  20. BPM-CUL3 E3 ligase modulates thermotolerance by facilitating negative regulatory domain-mediated degradation of DREB2A in Arabidopsis.

    PubMed

    Morimoto, Kyoko; Ohama, Naohiko; Kidokoro, Satoshi; Mizoi, Junya; Takahashi, Fuminori; Todaka, Daisuke; Mogami, Junro; Sato, Hikaru; Qin, Feng; Kim, June-Sik; Fukao, Yoichiro; Fujiwara, Masayuki; Shinozaki, Kazuo; Yamaguchi-Shinozaki, Kazuko

    2017-10-03

    DEHYDRATION-RESPONSIVE ELEMENT BINDING PROTEIN 2A (DREB2A) acts as a key transcription factor in both drought and heat stress tolerance in Arabidopsis and induces the expression of many drought- and heat stress-inducible genes. Although DREB2A expression itself is induced by stress, the posttranslational regulation of DREB2A, including protein stabilization, is required for its transcriptional activity. The deletion of a 30-aa central region of DREB2A known as the negative regulatory domain (NRD) transforms DREB2A into a stable and constitutively active form referred to as DREB2A CA. However, the molecular basis of this stabilization and activation has remained unknown for a decade. Here we identified BTB/POZ AND MATH DOMAIN proteins (BPMs), substrate adaptors of the Cullin3 (CUL3)-based E3 ligase, as DREB2A-interacting proteins. We observed that DREB2A and BPMs interact in the nuclei, and that the NRD of DREB2A is sufficient for its interaction with BPMs. BPM -knockdown plants exhibited increased DREB2A accumulation and induction of DREB2A target genes under heat and drought stress conditions. Genetic analysis indicated that the depletion of BPM expression conferred enhanced thermotolerance via DREB2A stabilization. Thus, the BPM-CUL3 E3 ligase is likely the long-sought factor responsible for NRD-dependent DREB2A degradation. Through the negative regulation of DREB2A stability, BPMs modulate the heat stress response and prevent an adverse effect of excess DREB2A on plant growth. Furthermore, we found the BPM recognition motif in various transcription factors, implying a general contribution of BPM-mediated proteolysis to divergent cellular responses via an accelerated turnover of transcription factors.

  1. Heart rate and use of beta-blockers in stable outpatients with coronary artery disease.

    PubMed

    Steg, Ph Gabriel; Ferrari, Roberto; Ford, Ian; Greenlaw, Nicola; Tardif, Jean-Claude; Tendera, Michal; Abergel, Hélène; Fox, Kim M

    2012-01-01

    Heart rate (HR) is an emerging risk factor in coronary artery disease (CAD). However, there is little contemporary data regarding HR and the use of HR-lowering medications, particularly beta-blockers, among patients with stable CAD in routine clinical practice. The goal of the present analysis was to describe HR in such patients, overall and in relation to beta-blocker use, and to describe the determinants of HR. CLARIFY is an international, prospective, observational, longitudinal registry of outpatients with stable CAD, defined as prior myocardial infarction or revascularization procedure, evidence of coronary stenosis of >50%, or chest pain associated with proven myocardial ischemia. A total of 33,438 patients from 45 countries in Europe, the Americas, Africa, Middle East, and Asia/Pacific were enrolled between November 2009 and July 2010. Most of the 33,177 patients included in this analysis were men (77.5%). Mean (SD) age was 64.2 (10.5) years, HR by pulse was 68.3 (10.6) bpm, and by electrocardiogram was 67.2 (11.4) bpm. Overall, 44.0% had HR ≥ 70 bpm. Beta-blockers were used in 75.1% of patients and another 14.4% had intolerance or contraindications to beta-blocker therapy. Among 24,910 patients on beta-blockers, 41.1% had HR ≥ 70 bpm. HR ≥ 70 bpm was independently associated with higher prevalence and severity of angina, more frequent evidence of myocardial ischemia, and lack of use of HR-lowering agents. Despite a high rate of use of beta-blockers, stable CAD patients often have resting HR ≥ 70 bpm, which was associated with an overall worse health status, more frequent angina and ischemia. Further HR lowering is possible in many patients with CAD. Whether it will improve symptoms and outcomes is being tested.

  2. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    PubMed

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Body image issues after bilateral prophylactic mastectomy with breast reconstruction in healthy women at risk for hereditary breast cancer.

    PubMed

    Gopie, Jessica P; Mureau, Marc A M; Seynaeve, Caroline; Ter Kuile, Moniek M; Menke-Pluymers, Marian B E; Timman, Reinier; Tibben, Aad

    2013-09-01

    The outcome of bilateral prophylactic mastectomy with breast reconstruction (BPM-IBR) in healthy BRCA1/2 mutation carriers can be potentially burdensome for body image and the intimate relationship. Therefore, in the current analysis the impact on body image, sexual and partner relationship satisfaction was prospectively investigated in women opting for BPM-IBR as well as cancer distress and general quality of life. Healthy women undergoing BPM-IBR completed questionnaires preoperatively (T0, n = 48), at 6 months (T1, n = 44) and after finishing breast reconstruction (median 21 months, range 12-35) (T2, n = 36). With multi-level regression analyses the course of outcome variables was investigated and a statistically significant change in body image and/or sexual and partner relationship satisfaction was predicted by baseline covariates. Body image significantly decreased at T1. At T2 sexual relationship satisfaction and body image tended to be lower compared to baseline. The overall partner relationship satisfaction did not significantly change. At T2, 37 % of the women reported that their breasts felt unpleasantly, 29 % was not satisfied with their breast appearance and 21 % felt embarrassed for their naked body. Most body image issues remained unchanged in 30 % of the women. A negative body image was predicted by high preoperative cancer distress. BPM-IBR was associated with adverse impact on body image in a substantial subgroup, but satisfaction with the overall sexual and partner relationship did not significantly change in time. The psychosocial impact of BPM-IBR in unaffected women should not be underestimated. Psychological support should ideally be integrated both before and after BPM-IBR.

  4. Effects of various mouthpieces on respiratory physiology during steady-state exercise in college-aged subjects.

    PubMed

    Garner, Dena P

    2015-01-01

    Protective mouthpieces have been used in a variety of sports to decrease the risk of orofacial injury. There are limited data to suggest that mouthpiece use during exercise may also provide an ergogenic effect. The aim of the present study was to investigate the effects of 3 different mouthpiece designs-boil-and-bite (BB) mouthpiece, ethylene vinyl acetate (EVA) custom mandibular mouthpiece, and polypropylene (Poly) custom mandibular mouthpiece-on respiratory physiology parameters and compare them with results of a no-mouthpiece (NM) condition. Sixteen college-aged, recreationally fit subjects ran for 10 minutes in 4 separate trials; mouthpiece conditions were randomly assigned to each trial for all subjects. Respiratory and cardiorespiratory measures, including oxygen uptake, carbon dioxide exhalation, ventilation, heart rate, tidal volume, and respiratory rate (RR), were assessed throughout testing. A repeated-measures analysis of variance indicated that RR was significantly lower (P = 0.04) in the BB mouthpiece condition (27.92 breaths per minute [BPM]) than in the NM condition (30.63 BPM). In paired t tests between conditions, the RR demonstrated in the BB condition (27.92 BPM) was significantly lower (P = 0.04) than that of each other condition (NM, 30.63 BPM; EVA, 29.92 BPM; and Poly, 29.92 BPM). The outcomes of the present study demonstrate that the use of the BB mouthpiece decreased RR during exercise. The differences cited between conditions may be attributed to the design of the mouthpiece and its mandibular placement as well as the activity of the genioglossus muscle. However, future studies should assess these parameters to determine the plausibility of these theories.

  5. Assembly and analysis of a male sterile rubber tree mitochondrial genome reveals DNA rearrangement events and a novel transcript.

    PubMed

    Shearman, Jeremy R; Sangsrakru, Duangjai; Ruang-Areerate, Panthita; Sonthirod, Chutima; Uthaipaisanwong, Pichahpuk; Yoocha, Thippawan; Poopear, Supannee; Theerawattanasuk, Kanikar; Tragoonrung, Somvong; Tangphatsornruang, Sithichoke

    2014-02-10

    The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility.

  6. Analytical N beam position monitor method

    NASA Astrophysics Data System (ADS)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  7. High Resolution BPM for Linear Colliders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, C.; Chel, S.; Luong, M.

    2006-11-20

    A high resolution Beam Position Monitor (BPM) is necessary for the beam-based alignment systems of high energy and low emittance electron linacs. Such a monitor is developed in the framework of the European CARE/SRF programme, in a close collaboration between DESY and CEA/DSM/DAPNIA. This monitor is a radiofrequency re-entrant cavity, which can be used either at room or cryogenic temperature, in an environment where dust particle contamination has to be avoided, such as superconducting cavities in a cryomodule. A first prototype of a re-entrant BPM has already delivered measurements at 2K. inside the first cryomodule (ACC1) on the TESLA Testmore » Facility 2 (TTF2). The performances of this BPM are analyzed both experimentally and theoretically, and the limitations of this existing system clearly identified. A new cavity and new electronics have been designed in order to improve the position resolution down to 1 {mu}m and the damping time down to 10 ns.« less

  8. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    PubMed

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Intraosseous Hydroxocobalamin versus Intravenous Hydroxocobalamin Compared to Intraosseous Whole Blood or No Treatment for Hemorrhagic Shock in a Swine Model

    DTIC Science & Technology

    2016-05-02

    MAP significantly improved over time in both treated groups but not in the control group. By 60 minutes, mean HR was 116 and 135 bpm and MAP was 60...and 65 mm Hg for IV and IO HOC groups (not significantly different) whereas non-treated animals displayed a mean HR of 157 bpm and MAP of 43 mm Hg...group. By 60 minutes, mean HR was 116(9.9) and 100(11.2) bpm and MAP was 57(3.9) and 62(4.4) mm Hg for IV HOC and WB groups (not significantly

  10. Modifying middle school physical education: piloting strategies to increase physical activity.

    PubMed

    Jago, Russell; McMurray, Robert G; Bassin, Stanley; Pyle, Laura; Bruecker, Steve; Jakicic, John M; Moe, Esther; Murray, Tinker; Volpe, Stella L

    2009-05-01

    Two pilot studies were conducted to examine whether 6th grade students can achieve moderate to vigorous physical activity (MVPA) from 1) activity-based physical education (AB-PE) with 585 participants and 2) a curricular-based (CB-PE) program with 1,544 participants and randomly sampled heart rates during lessons. AB-PE participants spent between 54-66% with a heart rate >140 bpm. CB-PE participants spent between 49-58% with a heart rate >140 bpm. Girls' mean heart rate was 3.7 bpm lower than the boys. PE can be readily modified so that students spend more than 50% of time in MVPA.

  11. Modifying Middle School Physical Education: Piloting Strategies to Increase Physical Activity

    PubMed Central

    Jago, Russell; McMurray, Robert G.; Bassin, Stanley; Pyle, Laura; Bruecker, Steve; Jakicic, John M.; Moe, Esther; Murray, Tinker; Volpe, Stella L.

    2009-01-01

    Two pilot studies were conducted to examine whether 6th grade students can achieve moderate to vigorous physical activity (MVPA) from 1) activity-based physical education (AB-PE) with 585 participants and 2) a curricular-based (CB-PE) program with 1,544 participants and randomly sampled heart rates during lessons. AB-PE participants spent between 54-66% with a heart rate >140 bpm. CB-PE participants spent between 49-58% with a heart rate >140 bpm. Girls' mean heart rate was 3.7 bpm lower than the boys. PE can be readily modified so that students spend more than 50% of time in MVPA. PMID:19556623

  12. Single-pass BPM system of the Photon Factory storage ring.

    PubMed

    Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y

    1998-05-01

    At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.

  13. Applications Where Snap is BPM for Radioactive Waste Assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, T.J.

    2008-07-01

    Historically, the Atomic Weapons Establishment (AWE) at Aldermaston in the United Kingdom (UK), has used a variety of assay techniques to measure the radioactive content of a diverse range of waste packages from decommissioning, operational and legacy sources. The regulator, the Environment Agency in the UK, places conditions and limits on AWE through an authorisation within the Radioactive Substances Act (RSA93). The conditions and limits require Best Practical Means (BPM) measurements to be used to demonstrate compliance with the authorisation. Hence, the assay technique employed needs to achieve a balance between risk of exposure, environmental considerations, technological considerations, health andmore » safety considerations and cost effectiveness, without being grossly disproportionate in terms of money, time or trouble. Recently published work has concluded that the Spectral Non-destructive Assay Platform (SNAP) assay system is BPM for Depleted Uranium (DU) waste assay at AWE (1) and low level plutonium in soft drummed waste, HEPA filters and soils (2-4). The purpose of this paper is to highlight other applications where SNAP represents BPM for radioactive waste assay. This has been done by intercomparison studies of SNAP with other assay techniques, such as Segmented Gamma Scanner (SGS) and Passive Neutron Coincidence Counter (PNCC). It has been concluded that, for a large range of waste packages encountered at AWE, SNAP is BPM. (author)« less

  14. Diltiazem vs. Metoprolol in the Management of Atrial Fibrillation or Flutter with Rapid Ventricular Rate in the Emergency Department.

    PubMed

    Fromm, Christian; Suau, Salvador J; Cohen, Victor; Likourezos, Antonios; Jellinek-Cohen, Samantha; Rose, Jonathan; Marshall, John

    2015-08-01

    Diltiazem (calcium channel blocker) and metoprolol (beta-blocker) are both commonly used to treat atrial fibrillation/flutter (AFF) in the emergency department (ED). However, there is considerable regional variability in emergency physician practice patterns and debate among physicians as to which agent is more effective. To date, only one small prospective, randomized trial has compared the effectiveness of diltiazem and metoprolol for rate control of AFF in the ED and concluded no difference in effectiveness between the two agents. Our aim was to compare the effectiveness of diltiazem with metoprolol for rate control of AFF in the ED. A convenience sample of adult patients presenting with rapid atrial fibrillation or flutter was randomly assigned to receive either diltiazem or metoprolol. The study team monitored each subject's systolic and diastolic blood pressures and heart rates for 30 min. In the first 5 min, 50.0% of the diltiazem group and 10.7% of the metoprolol group reached the target heart rate (HR) of <100 beats per minute (bpm) (p < 0.005). By 30 min, 95.8% of the diltiazem group and 46.4% of the metoprolol group reached the target HR < 100 bpm (p < 0.0001). Mean decrease in HR for the diltiazem group was more rapid and substantial than that of the metoprolol group. From a safety perspective, there was no difference between the groups with respect to hypotension (systolic blood pressure < 90 mm Hg) and bradycardia (HR < 60 bpm). Diltiazem was more effective in achieving rate control in ED patients with AFF and did so with no increased incidence of adverse effects. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Fresh stillborn and severely asphyxiated neonates share a common hypoxic-ischemic pathway.

    PubMed

    Ersdal, Hege L; Eilevstjønn, Joar; Linde, Jørgen E; Yeconia, Anita; Mduma, Estomih R; Kidanto, Hussein; Perlman, Jeffrey

    2018-05-01

    To characterize, among non-breathing flaccid neonates at delivery, immediate heartrate and responses to ventilation in relation to the clinical diagnosis of fresh stillbirth (FSB) or early neonatal death (END) within 24 hours. The present cross-sectional study included all deliveries at Haydom Hospital in rural Tanzania between July 1, 2013, and July 31, 2016. Ventilation parameters and heartrate were recorded by monitors with ventilation and dry-electrocardiography sensors. Perinatal characteristics were recorded on data forms by trained research assistants. Among 12 789 neonates delivered, 915 were ventilated; among ventilated neonates, there were 53 (6%) FSBs and 64 (7%) ENDs. Electrocardiography was used in 46 FSBs and 55 ENDs, and these neonates were included in a subanalysis. Initial heartrate was detected in 27 (59%) of 46 FSBs and 52 (95%) of 55 ENDs, and was lower in FSBs (52 ± 19 vs 76 ± 37 bpm; P=0.003). More ENDs responded to ventilation (53% vs 9%; P<0.001), with heartrate increasing above 100 bpm. Heartrate at ventilation discontinuation was higher among ENDs (115 ± 49 vs 52 ± 33 bpm; P<0.001). Progression to FSB or END after intrapartum hypoxia/anoxia is probably part of the same circulatory end-process. Distinguishing FSB from severely asphyxiated newborns is clinically difficult and probably influences estimated global perinatal mortality rates. © 2017 International Federation of Gynecology and Obstetrics.

  16. Accurate Heart Rate Monitoring During Physical Exercises Using PPG.

    PubMed

    Temko, Andriy

    2017-09-01

    The challenging task of heart rate (HR) estimation from the photoplethysmographic (PPG) signal, during intensive physical exercises, is tackled in this paper. The study presents a detailed analysis of a novel algorithm (WFPV) that exploits a Wiener filter to attenuate the motion artifacts, a phase vocoder to refine the HR estimate and user-adaptive post-processing to track the subject physiology. Additionally, an offline version of the HR estimation algorithm that uses Viterbi decoding is designed for scenarios that do not require online HR monitoring (WFPV+VD). The performance of the HR estimation systems is rigorously compared with existing algorithms on the publically available database of 23 PPG recordings. On the whole dataset of 23 PPG recordings, the algorithms result in average absolute errors of 1.97 and 1.37 BPM in the online and offline modes, respectively. On the test dataset of 10 PPG recordings which were most corrupted with motion artifacts, WFPV has an error of 2.95 BPM on its own and 2.32 BPM in an ensemble with two existing algorithms. The error rate is significantly reduced when compared with the state-of-the art PPG-based HR estimation methods. The proposed system is shown to be accurate in the presence of strong motion artifacts and in contrast to existing alternatives has very few free parameters to tune. The algorithm has a low computational cost and can be used for fitness tracking and health monitoring in wearable devices. The MATLAB implementation of the algorithm is provided online.

  17. Assembly and analysis of a male sterile rubber tree mitochondrial genome reveals DNA rearrangement events and a novel transcript

    PubMed Central

    2014-01-01

    Background The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. Results We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. Conclusions The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility. PMID:24512148

  18. Submicron multi-bunch BPM for CLIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmickler, H.; Soby, L.; /CERN

    2010-08-01

    A common-mode free cavity BPM is currently under development at Fermilab within the ILC-CLIC collaboration. This monitor will be operated in a CLIC Main Linac multi-bunch regime, and needs to provide both, high spatial and time resolution. We present the design concept, numerical analysis, investigation on tolerances and error effects, as well as simulations on the signal response applying a multi-bunch stimulus. The proposed CERN linear collider (CLIC) requires a very precise measurement of beam trajectory to preserve the low emittance when transporting the beam through the Main Linac. An energy chirp within the bunch train will be applied tomore » measure and minimize the dispersion effects, which require high resolution (in both, time and space) beam position monitors (BPM) along the beam-line. We propose a low-Q waveguide loaded TM{sub 110} dipole mode cavity as BPM, which is complemented by a TM{sub 010} monopole mode resonator of same resonant frequency for reference signal purposes. The design is based on a well known TM{sub 110} selective mode coupling idea.« less

  19. Growth performance and carcase quality in broiler chickens fed on bacterial protein grown on natural gas.

    PubMed

    Øverland, M; Schøyen, H F; Skrede, A

    2010-10-01

    1. The effects of increasing concentrations (0, 40, 80 or 120 g/kg) of bacterial protein meal (BPM) and bacterial protein autolysate (BPA) grown on natural gas on growth performance and carcase quality in broiler chickens were examined. 2. Adding BPM to diets reduced feed intake and improved gain: feed from 0 to 21 d and overall to 35 d, but did not significantly affect weight gain compared to the soybean meal based control diet. 3. Increasing concentrations of BPA significantly reduced growth rate, feed intake, gain: feed, carcase weight and dressing percentage, but significantly increased carcase dry matter, fat and energy content. 4. Adding BPM to diets had no effect on viscosity of diets and jejunal digesta, and minor effects on litter quality, whereas BPA increased the viscosity of diets and jejunal digesta, improved litter quality at 21 d, but decreased litter quality at 32 d. 5. To conclude, broiler chickens performed better on a BPM product with intact proteins than on an autolysate with ruptured cell walls and a high content of free amino acids and low molecular-weight peptides.

  20. Electromechanical Wave Imaging of biologically and electrically paced canine hearts in vivo

    PubMed Central

    Costet, Alexandre; Provost, Jean; Gambhir, Alok; Bobkov, Yevgeniy; Danilo, Peter; Boink, Gerard J.J.; Rosen, Michael R.; Konofagou, Elisa

    2014-01-01

    Ultrasound-based, Electromechanical Wave (EW) Imaging (EWI) can directly and entirely noninvasively map the transmural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability in localizing electronic and, for the first time, biological pacemakers in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR), and idioventricular rhythms occurring in dogs in heart block instrumented with electronic and biological pacemakers (EPM and BPM respectively). After AV node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n=4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n=2). EWI was performed transthoracically during NSR, BPM, and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/second. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison demonstrated that EWI was repeatable and reliable. These findings thus indicate the EWI potential to serve as a simple, noninvasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof. PMID:24239363

  1. Autonomic Dysfunction Precedes Development of Rheumatoid Arthritis: A Prospective Cohort Study

    PubMed Central

    Koopman, F.A.; Tang, M.W.; Vermeij, J.; de Hair, M.J.; Choi, I.Y.; Vervoordeldonk, M.J.; Gerlag, D.M.; Karemaker, J.M.; Tak, P.P.

    2016-01-01

    Background Heart rate variability (HRV) is a validated method to establish autonomic nervous system (ANS) activity. Rheumatoid arthritis (RA) is accompanied by ANS imbalance. We hypothesized that ANS dysfunction may precede the development of RA, which would suggest that it plays a role in its etiopathogenesis. Methods First, we assessed HRV parameters in supine (resting) and upright (active) position in healthy subjects (HS, n = 20), individuals at risk of developing arthritis (AR subjects, n = 50) and RA patients (RA, n = 20). Next, we measured resting heart rate (RHR), a parasympathetic HRV parameter, in an independent prospective cohort of AR subjects (n = 45). We also evaluated expression levels of the parasympathetic nicotinic acetylcholine receptor type 7 (α7nAChR) on circulating monocytes. Findings Both AR subjects (68 beats per minute (bpm), interquartile range (IQR) 68–73) and RA patients (68 bpm, IQR 62–76) had a significantly higher RHR compared to HS (60 bpm, IQR 56–63). RHR was significantly higher at baseline in individuals who subsequently developed arthritis. Expression levels of α7nAChR were lower in AR subjects with RHR ≥ 70 bpm compared to those with RHR < 70 bpm, consistent with reduced activity of the parasympathetic cholinergic anti-inflammatory pathway. Interpretation These data support the notion that autonomic dysfunction precedes the development of RA. PMID:27211565

  2. Hatching behavior of eastern long-necked turtles (Chelodina longicollis): The influence of asynchronous environments on embryonic heart rate and phenotype.

    PubMed

    McGlashan, Jessica K; Loudon, Fiona K; Thompson, Michael B; Spencer, Ricky-John

    2015-10-01

    Variable temperatures within a nest cause asynchronous development within clutches of freshwater turtle embryos, yet synchronous hatching occurs and is thought to be an important survival strategy for hatchlings. Metabolic compensation and circadian rhythms in heart rates of embryonic turtles indicate the potential of communication between embryos in a nest. Heart rates were used to identify metabolic circadian rhythms in clutches of an Australian freshwater turtle (Chelodina longicollis) and determine whether embryos metabolically compensate and hatch synchronously when incubated in asynchronous environments. The effects of a group environment during incubation on egg development and incubation period were also investigated during the final 3 weeks of development. Chelodina longicollis hatch synchronously and metabolically compensate so that less advanced embryos catch up to more advanced clutch-mates. Heart rates of embryos remained stable from week 4-7 in asynchronous (M=89 bpm) and synchronous (M=92 bpm) groups and declined in the final 2 weeks of incubation (M=72 and 77 bpm). Circadian rhythms were present throughout development and diel heart rates of embryos in asynchronous groups showed less deviation from the mean (M=-0.5 bpm) than synchronous groups (M=-4 bpm). Eggs incubated in groups had a significantly shorter incubation period than eggs incubated individually. Phenotypic traits including size, performance, and growth of all hatchlings were not affected. Egg position within a turtle nest is important for coordinating development throughout incubation and facilitating synchronous hatching. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  4. BPM-CUL3 E3 ligase modulates thermotolerance by facilitating negative regulatory domain-mediated degradation of DREB2A in Arabidopsis

    PubMed Central

    Morimoto, Kyoko; Ohama, Naohiko; Kidokoro, Satoshi; Mizoi, Junya; Takahashi, Fuminori; Todaka, Daisuke; Mogami, Junro; Sato, Hikaru; Qin, Feng; Kim, June-Sik; Fukao, Yoichiro; Fujiwara, Masayuki; Shinozaki, Kazuo; Yamaguchi-Shinozaki, Kazuko

    2017-01-01

    DEHYDRATION-RESPONSIVE ELEMENT BINDING PROTEIN 2A (DREB2A) acts as a key transcription factor in both drought and heat stress tolerance in Arabidopsis and induces the expression of many drought- and heat stress-inducible genes. Although DREB2A expression itself is induced by stress, the posttranslational regulation of DREB2A, including protein stabilization, is required for its transcriptional activity. The deletion of a 30-aa central region of DREB2A known as the negative regulatory domain (NRD) transforms DREB2A into a stable and constitutively active form referred to as DREB2A CA. However, the molecular basis of this stabilization and activation has remained unknown for a decade. Here we identified BTB/POZ AND MATH DOMAIN proteins (BPMs), substrate adaptors of the Cullin3 (CUL3)-based E3 ligase, as DREB2A-interacting proteins. We observed that DREB2A and BPMs interact in the nuclei, and that the NRD of DREB2A is sufficient for its interaction with BPMs. BPM-knockdown plants exhibited increased DREB2A accumulation and induction of DREB2A target genes under heat and drought stress conditions. Genetic analysis indicated that the depletion of BPM expression conferred enhanced thermotolerance via DREB2A stabilization. Thus, the BPM-CUL3 E3 ligase is likely the long-sought factor responsible for NRD-dependent DREB2A degradation. Through the negative regulation of DREB2A stability, BPMs modulate the heat stress response and prevent an adverse effect of excess DREB2A on plant growth. Furthermore, we found the BPM recognition motif in various transcription factors, implying a general contribution of BPM-mediated proteolysis to divergent cellular responses via an accelerated turnover of transcription factors. PMID:28923951

  5. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.

    PubMed

    Wiesel, Joseph; Arbesfeld, Benjamin; Schechter, David

    2014-10-01

    Screening for atrial fibrillation (AF) by assessing the pulse is recommended in high-risk patients. Some clinical trials demonstrated that the Microlife blood pressure monitor (BPM) with AF detection is more accurate than pulse palpation. This led to a change in practice guidelines in the United Kingdom where AF screening with the Microlife device is recommended instead of pulse palpation. Many BPMs have irregular heart beat detection, but they have not been shown to detect AF reliably. Recently, one study, in a highly select population, suggested that the Omron BPM with irregular heart beat detection has a higher sensitivity for AF than the Microlife BPM. We compared the Microlife and Omron BPMs to electrocardiographic readings for AF detection in general cardiology patients. Inclusion criteria were age≥50 years without a pacemaker or defibrillator. A total of 199 subjects were enrolled, 30 with AF. Each subject had a 12-lead electrocardiography, 1 Omron BPM reading, and 3 Microlife BPM readings as per device instructions. The Omron device had a sensitivity of 30% (95% confidence interval [CI] 15.4% to 49.1%) with the sensitivity for the first Microlife reading of 97% (95% CI 81.4% to 100%) and the Microlife readings using the majority rule (AF positive if at least 2 of 3 individual readings were positive for AF) of 100% (95% CI 85.9% to 100%). Specificity for the Omron device was 97% (95% CI 92.5% to 99.2%) and for the first Microlife reading of 90% (95% CI 83.8% to 94.2%) and for the majority rule Microlife device of 92% (95% CI 86.2% to 95.7%; p<0.0001). The specificity of both devices is acceptable, but only the Microlife BPM has a sensitivity value that is high enough to be used for AF screening in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram.

    PubMed

    Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J

    2016-04-01

    Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of  -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and  -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of  -5.6 to 5.2 bpm and a bias of  -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.

  7. Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

    PubMed

    Kroll, Ryan R; Boyd, J Gordon; Maslove, David M

    2016-09-20

    As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

  8. Diurnal, seasonal, and sex patterns of heart rate in grip-restrained African giant rats (Cricetomys gambianus, Waterhouse).

    PubMed

    Dzenda, Tavershima; Ayo, Joseph O; Sinkalu, Victor O; Yaqub, Lukuman S

    2015-10-01

    This study was carried out to determine heart rate (HR) values, including diurnal, seasonal, and sex patterns, in the African giant rat (Cricetomys gambianus, Waterhouse). HR was measured using stethoscope in grip-restrained African giant rats of either sex (103 bucks and 98 does), live-trapped from a tropical Savannah, and caged individually in the laboratory during the harmattan (cold-dry), hot-dry, and rainy seasons over a 3-year period. The HR fluctuated between 90 and 210 beats per minute (bpm) throughout the study period. Diurnal changes in HR (mean ± SEM) during the hot-dry and rainy seasons were nonsignificant (P > 0.05), but the morning and afternoon values differed (P < 0.01) during the cold-dry season. The HR varied (P < 0.05) among seasons, with peak, nadir, and moderate values recorded during the cold-dry (165.8 ± 0.51 bpm), hot-dry (153.1 ± 0.74 bpm), and rainy (163.4 ± 0.70 bpm) seasons, respectively. Mean HR of bucks was lower than that of does during the cold-dry (P < 0.0001) and hot-dry (P < 0.01) seasons, but sex difference during the rainy season was insignificant (P > 0.05). Overall, mean HR was lower (P < 0.0001) in bucks (158.8 ± 0.53 bpm) than in does (164.8 ± 0.53 bpm). In conclusion, values of HR in African giant rats are shown for the first time. Season, sex, and daytime influenced the HR, and should be considered during clinical evaluations of the rats. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  9. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram

    PubMed Central

    Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J

    2016-01-01

    Abstract Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of  −4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and  −5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of  −5.6 to 5.2 bpm and a bias of  −0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available. PMID:27027672

  10. Is 10-second electrocardiogram recording enough for accurately estimating heart rate in atrial fibrillation.

    PubMed

    Shuai, Wei; Wang, Xi-Xing; Hong, Kui; Peng, Qiang; Li, Ju-Xiang; Li, Ping; Chen, Jing; Cheng, Xiao-Shu; Su, Hai

    2016-07-15

    At present, the estimation of rest heart rate (HR) in atrial fibrillation (AF) is obtained by apical auscultation for 1min or on the surface electrocardiogram (ECG) by multiplying the number of RR intervals on the 10second recording by six. But the reasonability of 10second ECG recording is controversial. ECG was continuously recorded at rest for 60s to calculate the real rest HR (HR60s). Meanwhile, the first 10s and 30s ECG recordings were used for calculating HR10s (sixfold) and HR30s (twofold). The differences of HR10s or HR30s with the HR60s were compared. The patients were divided into three sub-groups on the HR60s <80, 80-100 and >100bpm. No significant difference among the mean HR10s, HR30s and HR60s was found. A positive correlation existed between HR10s and HR60s or HR30s and HR60s. Bland-Altman plot showed that the 95% reference limits were high as -11.0 to 16.0bpm for HR10s, but for HR30s these values were only -4.5 to 5.2bpm. Among the three subgroups with HR60s <80, 80-100 and >100bpm, the 95% reference limits with HR60s were -8.9 to 10.6, -10.5 to 14.0 and -11.3 to 21.7bpm for HR10s, but these values were -3.9 to 4.3, -4.1 to 4.6 and -5.3 to 6.7bpm for HR30s. As 10s ECG recording could not provide clinically accepted estimation HR, ECG should be recorded at least for 30s in the patients with AF. It is better to record ECG for 60s when the HR is rapid. Copyright © 2016. Published by Elsevier Ireland Ltd.

  11. Impact of heart rate in atrial fibrillation versus sinus rhythm on mortality in octogenarian patients with acute coronary syndrome.

    PubMed

    Li, Shijun; Barywani, Salim; Fu, Michael

    2017-01-01

    Association of heart rate (HR) with mortality in patients with acute coronary syndrome (ACS) and aged ≥ 80 years are underrepresented in clinical trials. We therefore aimed to investigate the association of HR in atrial fibrillation (AF) versus sinus rhythm (SR) with all-cause mortality in octogenarian patients with ACS. A total of 336 patients with ACS patients and aged ≥ 80 years were enrolled into the current study. The end point of interest was death from any cause. Association of HR in AF versus SR with mortality was analyzed by Kaplan-Meier curve following log-rank test and multivariable Cox regression analysis. In total, 63 (87.5%) of patients with AF were dead and 147 (59.8%) of patients with SR were dead during the follow-up period. The best cut-off was 80 bpm, with a sensitivity of 62% and specificity of 66%. HR ≤ 80 bpm in SR but not in AF was associated with better outcome as compared with HR > 80 bpm (Chi-Square = 26.55, Log rank P < 0.001). In SR subgroup, the hazard ratios of HR ≤ 80 bpm were 0.51(95% CI 0.37-0.70, P < 0.001) adjusted for age, 0.46 (95%CI 0.33-0.63, P < 0.001) adjusted for gender, 0.62 (95%CI 0.42- 0.93, P = 0.020) adjusted for multivariables respectively. In AF subgroup, the hazard ratios of HR ≤ 80 bpm were 0.83(95% CI 0.49-1.38, P = 0.464) adjusted for age, 0.96 (95%CI 0.59-1.58, P = 0.882) adjusted for gender, 0.72(95% CI 0.41-1.26, P = 0.249) adjusted for multivariables respectively. The current study demonstrates that heart rate is an independent prognostic predictor for all-cause mortality, and HR ≤ 80 bpm is associated with improved outcome in SR but not in AF in octogenarian patients with ACS.

  12. Changes in Functional Mobility and Musculoskeletal Pain After Bariatric Surgery in Teens With Severe Obesity: Teen-Longitudinal Assessment of Bariatric Surgery (LABS) Study.

    PubMed

    Ryder, Justin R; Edwards, Nicholas M; Gupta, Resmi; Khoury, Jane; Jenkins, Todd M; Bout-Tabaku, Sharon; Michalsky, Marc P; Harmon, Carroll M; Inge, Thomas H; Kelly, Aaron S

    2016-09-01

    Severe obesity is associated with mobility limitations and higher incidence of multijoint musculoskeletal pain. It is unknown whether substantial weight loss improves these important outcomes in adolescents with severe obesity. To examine the association of bariatric surgery with functional mobility and musculoskeletal pain in adolescents with severe obesity up to 2 years after surgery. The Teen-Longitudinal Assessment of Bariatric Surgery Study is a prospective, multicenter, observational study, which enrolled 242 adolescents (≤19 years of age) who were undergoing bariatric surgery from March 2007 through February 2012 at 5 US adolescent bariatric surgery centers. This analysis was conducted in November 2015. Roux-en-Y gastric bypass (n = 161), sleeve gastrectomy (n = 67), or laparoscopic adjustable gastric band (n = 14). Participants completed a 400-m walk test prior to bariatric surgery (n = 206) and at 6 months (n = 195), 12 months (n = 176), and 24 months (n = 149) after surgery. Time to completion, resting heart rate (HR), immediate posttest HR, and HR difference (resting HR minus posttest HR) were measured and musculoskeletal pain concerns, during and after the test, were documented. Data were adjusted for age, sex, race/ethnicity, baseline body mass index (calculated as weight in kilograms divided by height in meters squared), and surgical center (posttest HR and HR difference were further adjusted for changes in time to completion). Of the 206 adolescents with severe obesity included in the study, 156 were female (75.7%), the mean (SD) age was 17.1 (1.6) years, and the mean (SD) body mass index was 51.7 (8.5). Compared with baseline, significant improvements were observed at 6 months for the walk test time to completion (mean, 376 seconds; 95% CI, 365-388 to 347 seconds; 95% CI, 340-358; P < .01), resting HR (mean, 84 beats per minute [bpm]; 95% CI, 82-86 to 74 bpm; 95% CI, 72-76), posttest HR (mean, 128 bpm; 95% CI, 125-131 to 113 bpm; 95% CI, 110-116), and HR difference (mean, 40 bpm; 95% CI, 36-42 to 34 bpm; 95% CI, 31-37). These changes in time to completion, resting HR, and HR difference persisted at 12 months and 24 months. Posttest HR further improved from 6 months to 12 months (mean, 113 bpm; 95% CI, 110-116 to 108 bpm; 95% CI, 105-111). There were statistically significant reductions in musculoskeletal pain concerns at all points. These data provide evidence that bariatric surgery in adolescents with severe obesity is associated with significant improvement in functional mobility and in the reduction of walking-related musculoskeletal pain up to 2 years after surgery.

  13. An Econometric Examination of the Behavioral Perspective Model in the Context of Norwegian Retailing

    ERIC Educational Resources Information Center

    Sigurdsson, Valdimar; Kahamseh, Saeed; Gunnarsson, Didrik; Larsen, Nils Magne; Foxall, Gordon R.

    2013-01-01

    The behavioral perspective model's (BPM; Foxall, 1990) retailing literature is built on extensive empirical research and techniques that were originally refined in choice experiments in behavioral economics and behavior analysis, and then tested mostly on British consumer panel data. We test the BPM in the context of Norwegian retailing. This…

  14. A neutral-beam profile monitor with a phosphor screen and a high-sensitivity camera for the J-PARC KOTO experiment

    NASA Astrophysics Data System (ADS)

    Matsumura, T.; Kamiji, I.; Nakagiri, K.; Nanjo, H.; Nomura, T.; Sasao, N.; Shinkawa, T.; Shiomi, K.

    2018-03-01

    We have developed a beam-profile monitor (BPM) system to align the collimators for the neutral beam-line at the Hadron Experimental Facility of J-PARC. The system is composed of a phosphor screen and a CCD camera coupled to an image intensifier mounted on a remote control X- Y stage. The design and detailed performance studies of the BPM are presented. The monitor has a spatial resolution of better than 0.6 mm and a deviation from linearity of less than 1%. These results indicate that the BPM system meets the requirements to define collimator-edge positions for the beam-line tuning. Confirmation using the neutral beam for the KOTO experiment is also presented.

  15. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    NASA Astrophysics Data System (ADS)

    Thieberger, P.; Gassner, D.; Hulsart, R.; Michnoff, R.; Miller, T.; Minty, M.; Sorrell, Z.; Bartnik, A.

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  16. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE PAGES

    Thieberger, Peter; Gassner, D.; Hulsart, R.; ...

    2018-04-25

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  17. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thieberger, Peter; Gassner, D.; Hulsart, R.

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  18. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets.

    PubMed

    Thieberger, P; Gassner, D; Hulsart, R; Michnoff, R; Miller, T; Minty, M; Sorrell, Z; Bartnik, A

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  19. MIA analysis of FPGA BPMs and beam optics at APS

    NASA Astrophysics Data System (ADS)

    Ji, Da-Heng; Wang, Chun-Xi; Qin, Qing

    2012-11-01

    Model independent analysis, which was developed for high precision and fast beam dynamics analysis, is a promising diagnostic tool for modern accelerators. We implemented a series of methods to analyze the turn-by-turn BPM data. Green's functions corresponding to the local transfer matrix elements R12 or R34 are extracted from BPM data and fitted with the model lattice using least-square fitting. Here, we report experimental results obtained from analyzing the transverse motion of a beam in the storage ring at the Advanced Photon Source. BPM gains and uncoupled optics parameters are successfully determined. Quadrupole strengths are adjusted for fitting but can not be uniquely determined in general due to an insufficient number of BPMs.

  20. Validation of the CQU-DTU-LN1 series of airfoils

    NASA Astrophysics Data System (ADS)

    Shen, W. Z.; Zhu, W. J.; Fischer, A.; Garcia, N. R.; Cheng, J. T.; Chen, J.; Madsen, J.

    2014-12-01

    The CQU-DTU-LN1 series of airfoils were designed with an objective of high lift and low noise emission. In the design process, the aerodynamic performance is obtained using XFOIL while noise emission is obtained with the BPM model. In this paper we present some validations of the designed CQU-DTU-LN118 airfoil by using wind tunnel measurements in the acoustic wind tunnel located at Virginia Tech and numerical computations with the inhouse Q3uic and EllipSys 2D/3D codes. To show the superiority of the new airfoils, comparisons with a NACA64618 airfoil are made. For the aerodynamic features, the designed Cl and Cl/Cd agrees well with the experiment and are in general higher than those of the NACA airfoil. For the acoustic features, the noise emission of the LN118 airfoil is compared with the acoustic measurements and that of the NACA airfoil. Comparisons show that the BPM model can predict correctly the noise changes.

  1. Imaging complex objects using learning tomography

    NASA Astrophysics Data System (ADS)

    Lim, JooWon; Goy, Alexandre; Shoreh, Morteza Hasani; Unser, Michael; Psaltis, Demetri

    2018-02-01

    Optical diffraction tomography (ODT) can be described using the scattering process through an inhomogeneous media. An inherent nonlinearity exists relating the scattering medium and the scattered field due to multiple scattering. Multiple scattering is often assumed to be negligible in weakly scattering media. This assumption becomes invalid as the sample gets more complex resulting in distorted image reconstructions. This issue becomes very critical when we image a complex sample. Multiple scattering can be simulated using the beam propagation method (BPM) as the forward model of ODT combined with an iterative reconstruction scheme. The iterative error reduction scheme and the multi-layer structure of BPM are similar to neural networks. Therefore we refer to our imaging method as learning tomography (LT). To fairly assess the performance of LT in imaging complex samples, we compared LT with the conventional iterative linear scheme using Mie theory which provides the ground truth. We also demonstrate the capacity of LT to image complex samples using experimental data of a biological cell.

  2. Acid and base recovery from brine solution using PVP intermediate-based bipolar membrane through water splitting technology

    NASA Astrophysics Data System (ADS)

    Venugopal, Krishnaveni; Murugappan, Minnoli; Dharmalingam, Sangeetha

    2017-07-01

    Potable water has become a scarce resource in many countries. In fact, the world is not running out of water, but rather, the relatively fixed quantity is becoming too contaminated for many applications. Hence, the present work was designed to evaluate the desalination efficiency of resin and glass fiber-reinforced Polysulfone polymer-based monopolar and bipolar (BPM) ion exchange membranes (with polyvinyl pyrrolidone as the intermediate layer) on a real sample brine solution for 8 h duration. The prepared ion exchange membranes (IEMs) were characterized using FTIR, SEM, TGA, water absorption, and contact angle measurements. The BPM efficiency, electrical conductivity, salinity, sodium, and chloride ion concentration were evaluated for both prepared and commercial-based IEM systems. The current efficiency and energy consumption values obtained during BPMED process were found to be 45 % and 0.41 Wh for RPSu-PVP-based IEM system and 38 % and 1.60 Wh for PSDVB-based IEM system, respectively.

  3. Experimental investigation of trailing edge noise from stationary and rotating airfoils

    PubMed Central

    Zajamsek, Branko; Doolan, Con J.; Moreau, Danielle J.; Fischer, Jeoffrey; Prime, Zebb

    2017-01-01

    Trailing edge noise from stationary and rotating NACA 0012 airfoils is characterised and compared with a noise prediction based on the semi-empirical Brooks, Pope, and Marcolini (BPM) model. The NACA 0012 is symmetrical airfoil with no camber and 12% thickness to chord length ratio. Acoustic measurements were conducted in an anechoic wind tunnel using a stationary NACA 0012 airfoil at 0° pitch angle. Airfoil self-noise emissions from rotating NACA 0012 airfoils mounted at 0° and 10° pitch angles on a rotor-rig are studied in an anechoic room. The measurements were carried out using microphone arrays for noise localisation and magnitude estimation using beamforming post-processing. Results show good agreement between peak radiating trailing edge noise emissions of stationary and rotating NACA 0012 airfoils in terms of the Strouhal number. Furthermore, it is shown that noise predictions based on the BPM model considering only two dimensional flow effects, are in good agreement with measurements for rotating airfoils, at these particular conditions. PMID:28599535

  4. Experimental investigation of trailing edge noise from stationary and rotating airfoils.

    PubMed

    Zajamsek, Branko; Doolan, Con J; Moreau, Danielle J; Fischer, Jeoffrey; Prime, Zebb

    2017-05-01

    Trailing edge noise from stationary and rotating NACA 0012 airfoils is characterised and compared with a noise prediction based on the semi-empirical Brooks, Pope, and Marcolini (BPM) model. The NACA 0012 is symmetrical airfoil with no camber and 12% thickness to chord length ratio. Acoustic measurements were conducted in an anechoic wind tunnel using a stationary NACA 0012 airfoil at 0° pitch angle. Airfoil self-noise emissions from rotating NACA 0012 airfoils mounted at 0° and 10° pitch angles on a rotor-rig are studied in an anechoic room. The measurements were carried out using microphone arrays for noise localisation and magnitude estimation using beamforming post-processing. Results show good agreement between peak radiating trailing edge noise emissions of stationary and rotating NACA 0012 airfoils in terms of the Strouhal number. Furthermore, it is shown that noise predictions based on the BPM model considering only two dimensional flow effects, are in good agreement with measurements for rotating airfoils, at these particular conditions.

  5. Measurements of a Newly Designed BPM for the Tevatron Electron Lens 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpine, V. E.; Kamerdzhiev, V.; Fellenz, B.

    2006-11-20

    Fermilab has developed a second electron lens (TEL-2) for beam-beam compensation in the Tevatron as part of its Run II upgrade program. Operation of the beam position monitors (BPMs) in the first electron lens (TEL-1) showed a systematic transverse position difference between short proton bunches (2 ns sigma) and long electron pulses ({approx}1 us) of up to {approx}1.5 mm. This difference was attributed to frequency dependence in the BPM system. The TEL-2 BPMs utilize a new, compact four-plate design with grounding strips between plates to minimize crosstalk. In-situ measurements of these new BPMs are made using a stretched wire pulsedmore » with both proton and electron beam formats. In addition, longitudinal impedance measurements of the TEL-2 are presented. Signal processing algorithm studies indicate that the frequency-dependent transverse position offset may be reduced to {approx}0.1 mm for the beam structures of interest.« less

  6. APS Storage Ring Monopulse RF BPM Upgrade

    NASA Astrophysics Data System (ADS)

    Lill, R.; Pietryla, A.; Norum, E.; Lenkszus, F.

    2004-11-01

    The Advanced Photon Source (APS) is a third-generation synchrotron light source in its ninth year of operation. The storage ring monopulse radio frequency (rf) beam position monitor (BPM) was designed to measure single-turn and multi-turn beam positions for operations and machine physics studies. Many of the components used in the original design are obsolete and costly to replace. In this paper we present a proposal to upgrade the monopulse rf BPMs in which the existing system hardware is repartitioned and the aging data acquisition system is replaced. By replacing only the data acquisition system, we will demonstrate a cost-effective approach to improved beam stability, reliability, and enhanced postmortem capabilities. An eight-channel ADC/digitizer VXI board with sampling rate of up to 105 MHz (per channel) and 14-bit resolution coupled with a field-programmable gate array and embedded central processing will provide the flexibility to revitalize this system for another decade of operation. We will discuss the upgrade system specifications, design, and prototype test results.

  7. Relation between detection rate and inappropriate shocks in single versus dual chamber cardioverter-defibrillator – an analysis from the OPTION trial

    PubMed Central

    Kolb, Christof; Sturmer, Marcio; Babuty, Dominique; Sick, Peter; Davy, Jean Marc; Molon, Giulio; Schwab, Jörg Otto; Mantovani, Giuseppe; Wickliffe, Andrew; Lennerz, Carsten; Semmler, Verena; Siot, Pierre-Henri; Reif , Sebastian

    2016-01-01

    The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ algorithm. In a post-hoc analysis, rates of patients with inappropriate and appropriate shocks were calculated for shocks triggered at heart rates ≥170 bpm (ventricular tachycardia zone) and at rates ≥200 bpm (ventricular fibrillation zone). In the SC group, higher rates of patients with total and inappropriate shocks were delivered at heart rates ≥170 bpm than at rates ≥200 bpm (total shocks: 21.1% vs. 16.6%; p = 0.002; inappropriate shocks: 7.6% vs. 4.5%, p = 0.016; appropriate shocks: 15.2% vs. 13.5%; p = n.s.). No such differences were observed in the DC group (total shocks: 14.3% vs. 12.6%; p = n.s.; inappropriate shocks: 3.9% vs. 3.6%; p = n.s.; appropriate shocks: 12.2% vs. 10.4%; p = n.s.). The higher frequency of patients with total shocks with SC settings than with DC settings that benefit from PARAD+ was driven by a higher percentage of patients with inappropriate shocks in the VT zone (170–200 bpm) in the SC population. PMID:26892534

  8. The Brief Problem Monitor-Parent form (BPM-P), a short version of the Child Behavior Checklist: Psychometric properties in Spanish 6- to 8-year-old children.

    PubMed

    Penelo, Eva; de la Osa, Núria; Navarro, José Blas; Domènech, Josep Maria; Ezpeleta, Lourdes

    2017-11-01

    We provide the first validation data on the Spanish version of the Brief Problem Monitor-Parent form (BPM-P), a recently developed abbreviated version of the 120-item Child Behavior Checklist for Ages 6 to 18 (CBCL/6-18) in young schoolchildren. Parents of a community sample of 521 children aged 6-8 answered the CBCL/6-18 yearly, and the 19 BPM-P items were examined; parents also provided different measures of psychopathology. Confirmatory factor analysis of the expected 3-factor model (attention, externalizing, and internalizing) showed adequate fit (root mean square error of approximation, RMSEA ≤ .057), and measurement invariance across sex and age was observed. Internal consistency for the derived scores was satisfactory (ω ≥ .83). Concurrent validity with the equivalent scale scores of the original full CBCL/6-18 (r ≥ .84) and convergent validity with parents' ratings of the Strengths and Difficulties Questionnaire scores (r ≥ .52) were good. BPM-P scores at age 7 showed good predictive accuracy for discriminating the use of mental health services (OR ≥ 1.12), functional impairment (B ≤ -1.25), and the presence of the corresponding disorders diagnosed with an independent clinical interview, both cross-sectionally at age 7 and longitudinally at age 8 (OR ≥ 1.24). The BPM-P provides reliable and valid scores as a very brief follow-up and screening tool for assessing behavioral and emotional problems in young schoolchildren. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  10. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  11. A Novel WA-BPM Based on the Generalized Multistep Scheme in the Propagation Direction in the Waveguide

    NASA Astrophysics Data System (ADS)

    Ji, Yang; Chen, Hong; Tang, Hongwu

    2017-06-01

    A highly accurate wide-angle scheme, based on the generalized mutistep scheme in the propagation direction, is developed for the finite difference beam propagation method (FD-BPM). Comparing with the previously presented method, the simulation shows that our method results in a more accurate solution, and the step size can be much larger

  12. Biological Parametric Mapping: A Statistical Toolbox for Multi-Modality Brain Image Analysis

    PubMed Central

    Casanova, Ramon; Ryali, Srikanth; Baer, Aaron; Laurienti, Paul J.; Burdette, Jonathan H.; Hayasaka, Satoru; Flowers, Lynn; Wood, Frank; Maldjian, Joseph A.

    2006-01-01

    In recent years multiple brain MR imaging modalities have emerged; however, analysis methodologies have mainly remained modality specific. In addition, when comparing across imaging modalities, most researchers have been forced to rely on simple region-of-interest type analyses, which do not allow the voxel-by-voxel comparisons necessary to answer more sophisticated neuroscience questions. To overcome these limitations, we developed a toolbox for multimodal image analysis called biological parametric mapping (BPM), based on a voxel-wise use of the general linear model. The BPM toolbox incorporates information obtained from other modalities as regressors in a voxel-wise analysis, thereby permitting investigation of more sophisticated hypotheses. The BPM toolbox has been developed in MATLAB with a user friendly interface for performing analyses, including voxel-wise multimodal correlation, ANCOVA, and multiple regression. It has a high degree of integration with the SPM (statistical parametric mapping) software relying on it for visualization and statistical inference. Furthermore, statistical inference for a correlation field, rather than a widely-used T-field, has been implemented in the correlation analysis for more accurate results. An example with in-vivo data is presented demonstrating the potential of the BPM methodology as a tool for multimodal image analysis. PMID:17070709

  13. Analysis of a Novel Diffractive Scanning Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatchyn, Roman; /SLAC

    2011-09-01

    Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPMmore » with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.« less

  14. Design, test, and calibration of an electrostatic beam position monitor

    NASA Astrophysics Data System (ADS)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  15. LBNP as useful tool for pilot candidates selection to the Polish Air Force: a preliminary study.

    PubMed

    Romuald, M; Mariusz, Z; Artur, D; Krzysztof, R

    2001-07-01

    Candidates to the Polish Air Force are to fulfill strict medical conditions. Every candidate, wanting to become a fighter pilot or not, has to pass a rigorous centrifuge examination. This is a costly and especially stressful process for the candidates, as first-timers. This article explores possibility for different approach to candidates fitness to fly assessment. 14 candidates (21-22 yrs old) were subjected to a regular GOR centrifuge profile (0.1 G/s; up to +7.0 Gz; unprotected) and to lower body negative pressure (LBNP) examination (2 min. rest period followed by 3 min. at -40 mm Hg; supine position). Both, centrifuge and LBNP examinations were carried out the same day, with about 1 hour gap between them. ECG and impedance cardiography (ICG) were being recorded during both tests. The following parameters were calculated: HR and QZ (time between ventricular depolarization [beginning of the Q wave in ECG] and local maximum of the first derivative [dZ/dt] in ICG). QZ was considered to be an effective measure of dynamic heart function. +Gz tolerance for the group was +5.94 +/- 0.98 Gz. Correlation between +Gz tolerance and QZ values during LBNP test (-40 mm Hg) for all subjects was equal to r=0.6. Correlation between sets of parameters (canonical analysis) for LBNP and centrifuge was equal to r=0.78. Both results were statistically insignificant (p<0.09). Baseline HR values were 121 +/- 19 bpm and 75 +/- 12 bpm, and maximal HR values were 172 +/- 21 bpm and 81 +/- 13 bpm, respectively for centrifuge and LBNP. For both, baseline and maximal HR during LBNP and G exposure canonical correlation was equal to r=0.72. The results were statistically not significant, however. Centrifuge examination is much more stressful than LBNP test. This could have implication on the objective results of centrifuge test. The results may suggest that LBNP test could be a used in pilot candidates selection, especially those presenting high baseline HR values.

  16. Beam-based calibrations of the BPM offset at C-ADS Injector II

    NASA Astrophysics Data System (ADS)

    Chen, Wei-Long; Wang, Zhi-Jun; Feng, Chi; Dou, Wei-Ping; Tao, Yue; Jia, Huan; Wang, Wang-Sheng; Liu, Shu-Hui; He, Yuan

    2016-07-01

    Beam-based BPM offset calibration was carried out for Injector II at the C-ADS demonstration facility at the Institute of Modern Physics (IMP), Chinese Academy of Science (CAS). By using the steering coils integrated in the quadrupoles, the beam orbit can be effectively adjusted and BPM positions recorded at the Medium Energy Beam Transport of the Injector II Linac. The studies were done with a 2 mA, 2.1 MeV proton beam in pulsed mode. During the studies, the “null comparison method” was applied for the calibration. This method is less sensitive to errors compared with the traditional transmission matrix method. In addition, the quadrupole magnet’s center can also be calibrated with this method. Supported by National Natural Science Foundation of China (91426303, 11525523)

  17. Heart Rate assessment by means of a novel approach applied to signals of different nature

    NASA Astrophysics Data System (ADS)

    Cosoli, G.; Casacanditella, L.; Tomasini, EP; Scalise, L.

    2017-01-01

    Electrocardiographic (ECG) signal presents many clinically relevant features (e.g. QT-interval, that is the duration of the ventricular depolarization). A novel processing technique has been demonstrated to be capable to measure some important characteristics according to the morphology of the waveform. Basing on that, the aim of this work is to propose an improved algorithm and to prove its efficacy in the assessment of the subject’s Heart Rate (HR) in comparison to standard algorithms (i.e. Pan & Tompkins). Results obtained in experimentally collected ECG signals for the identification of the main feature (R-peak) are comparable to those obtained with the traditional approach (sensitivity of 99.55% and 99.95%, respectively). Moreover, the use of this algorithm has been broaden to signals coming from different biomedical sensors (based on optical, acoustical and mechanical principles), all related to blood flow, for the computation of HR. In particular, it has been employed to PCG (Phonocardiography), PPG (Photoplethysmography) and VCG (Vibrocardiography), where standard algorithms could not be widely applied. HR results from a measurement campaign on 8 healthy subjects have shown, with respect to ECG, deviations (calculated as 2σ) of ±3.3 bpm, ±2.3 bpm and ±1.5 bpm for PCG, PPG and VCG, respectively. In conclusion, it is possible to state that the adopted algorithm is able to measure HR accurately from different biosignals. Future work will involve the extraction of additional morphological features in order to characterise the waveforms more deeply and to better describe the subject’s health status.

  18. Heart Rates of High School Physical Education Students during Team Sports, Individual Sports, and Fitness Activities

    ERIC Educational Resources Information Center

    Laurson, Kelly R.; Brown, Dale D.; Cullen, Robert W.; Dennis, Karen K.

    2008-01-01

    This study examined how activity type influenced heart rates and time spent in target heart rate zones of high school students participating in physical education classes. Significantly higher average heart rates existed for fitness (142 plus or minus 24 beats per minute [bpm]) compared to team (118 plus or minus 24 bpm) or individual (114 plus or…

  19. Ultraviolet carbon lines in the spectrum of the white dwarf BPM 11668

    NASA Technical Reports Server (NTRS)

    Wegner, G.

    1983-01-01

    The southern hemisphere DC white dwarf BPM 11668 has been found to show strong ultraviolet lines of neutral carbon using observations from the IUE satellite. This star seems typical of the growing number of DC white dwarfs found to be of this type and appears to have a carbon abundance near C:He = 0.0001, with an effective temperature of 8500 K.

  20. Bipedal hopping timed to a metronome to detect impairments in anticipatory motor control in people with mild multiple sclerosis.

    PubMed

    Kirkland, Megan C; Chen, Alice; Downer, Matthew B; Holloway, Brett J; Wallack, Elizabeth M; Lockyer, Evan J; Buckle, Natasha C M; Abbott, Courtney L; Ploughman, Michelle

    2018-06-01

    People with mild multiple sclerosis (MS) often report subtle deficits in balance and cognition but display no measurable impairment on clinical assessments. We examined whether hopping to a metronome beat had the potential to detect anticipatory motor control deficits among people with mild MS (Expanded Disability Status Scale ≤ 3.5). Participants with MS (n = 13), matched controls (n = 9), and elderly subjects (n = 13) completed tests of cognition (Montreal Cognitive Assessment (MoCA)) and motor performance (Timed 25 Foot Walk Test (T25FWT)). Participants performed two bipedal hopping tasks: at 40 beats/min (bpm) and 60-bpm in random order. Hop characteristics (length, symmetry, variability) and delay from the metronome beat were extracted from an instrumented walkway and compared between groups. The MS group became more delayed from the metronome beat over time whereas elderly subjects tended to hop closer to the beat (F = 4.52, p = 0.02). Delay of the first hop during 60-bpm predicted cognition in people with MS (R = 0.55, β = 4.64 (SD 4.63), F = 4.85, p = 0.05) but not among control (R = 0.07, p = 0.86) or elderly subjects (R = 0.17, p = 0.57). In terms of hopping characteristics, at 60-bpm, people with MS and matched controls were significantly different from the elderly group. However, at 40-bpm, the MS group was no longer significantly different from the elderly group, even though matched controls and elderly still differed significantly. This new timed hopping test may be able to detect both physical ability, and feed-forward anticipatory control impairments in people with mild MS. Hopping at a frequency of 40-bpm seemed more challenging. Several aspects of anticipatory motor control can be measured: including reaction time to the first metronome cue and the ability to adapt and anticipate the beat over time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  1. Sex Differences in Cardiac Baroreflex Sensitivity after Isometric Handgrip Exercise.

    PubMed

    Teixeira, André L; Ritti-Dias, Raphael; Antonino, Diego; Bottaro, Martim; Millar, Philip J; Vianna, Lauro C

    2018-04-01

    This study aimed to investigate potential sex-related differences on spontaneous cardiac baroreflex sensitivity (cBRS) after acute isometric handgrip (IHG) exercise. Twenty men (age, 23 ± 3 yr) and 20 women (age, 24 ± 4 yr) randomly performed four sets of 2-min IHG exercise (two sets for each limb) at 30% maximal voluntary contraction (experimental) or 3% maximal voluntary contraction (sham). Beat-to-beat heart rate (HR) and arterial blood pressure (BP) were monitored using finger photoplethysmography before and 10, 20, and 30 min after IHG. Spontaneous cBRS was assessed via the sequence technique and cardiac autonomic modulation via time- and frequency-domain HR variability. After IHG, spontaneous cBRS increased during 10 min of recovery in men (Δ13% ± 5%, P = 0.03 vs rest) and increased further in women (Δ23% ± 4%, P < 0.01 vs rest; P = 0.04 vs men). During 20 and 30 min of recovery, cBRS returned to baseline in men but remained elevated in women. HR decreased 10 min after IHG in men (10 min: Δ-2 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-1 ± 1 bpm, P = 0.39 vs rest; 30 min: Δ1 ± 1 bpm, P = 0.31 vs rest) and throughout recovery in women (10 min: Δ-5 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-3 ± 1 bpm, P < 0.01 vs rest; 30 min: Δ-2 ± 1 bpm, P < 0.01 vs rest). Systolic BP increased 10 min after IHG and remained elevated during 20 min and 30 min in men (P < 0.05). In women, systolic BP increased during 10 min (P < 0.01) and returned to baseline during 20 and 30 min of recovery. Time-domain HR variability (root mean square of successive differences) was increased during recovery in men and women (P < 0.05). Sham had no effect on any variables. Acute IHG exercise increases cBRS and cardiac vagal activity in healthy young subjects, but the magnitude and the time course of changes in cBRS differ between men and women.

  2. Impact of heart rate in atrial fibrillation versus sinus rhythm on mortality in octogenarian patients with acute coronary syndrome

    PubMed Central

    Li, Shijun; Barywani, Salim; Fu, Michael

    2017-01-01

    Introduction Association of heart rate (HR) with mortality in patients with acute coronary syndrome (ACS) and aged ≥ 80 years are underrepresented in clinical trials. We therefore aimed to investigate the association of HR in atrial fibrillation (AF) versus sinus rhythm (SR) with all-cause mortality in octogenarian patients with ACS. Methods A total of 336 patients with ACS patients and aged ≥ 80 years were enrolled into the current study. The end point of interest was death from any cause. Association of HR in AF versus SR with mortality was analyzed by Kaplan-Meier curve following log-rank test and multivariable Cox regression analysis. Results In total, 63 (87.5%) of patients with AF were dead and 147 (59.8%) of patients with SR were dead during the follow-up period. The best cut-off was 80 bpm, with a sensitivity of 62% and specificity of 66%. HR ≤ 80 bpm in SR but not in AF was associated with better outcome as compared with HR > 80 bpm (Chi-Square = 26.55, Log rank P < 0.001). In SR subgroup, the hazard ratios of HR ≤ 80 bpm were 0.51(95% CI 0.37-0.70, P < 0.001) adjusted for age, 0.46 (95%CI 0.33-0.63, P < 0.001) adjusted for gender, 0.62 (95%CI 0.42- 0.93, P = 0.020) adjusted for multivariables respectively. In AF subgroup, the hazard ratios of HR ≤ 80 bpm were 0.83(95% CI 0.49-1.38, P = 0.464) adjusted for age, 0.96 (95%CI 0.59-1.58, P = 0.882) adjusted for gender, 0.72(95% CI 0.41-1.26, P = 0.249) adjusted for multivariables respectively. Conclusion The current study demonstrates that heart rate is an independent prognostic predictor for all-cause mortality, and HR ≤ 80 bpm is associated with improved outcome in SR but not in AF in octogenarian patients with ACS. PMID:29255559

  3. Is the work flow model a suitable candidate for an observatory supervisory control infrastructure?

    NASA Astrophysics Data System (ADS)

    Daly, Philip N.; Schumacher, Germán.

    2016-08-01

    This paper reports on the early investigation of using the work flow model for observatory infrastructure software. We researched several work ow engines and identified 3 for further detailed, study: Bonita BPM, Activiti and Taverna. We discuss the business process model and how it relates to observatory operations and identify a path finder exercise to further evaluate the applicability of these paradigms.

  4. Electromechanical wave imaging of biologically and electrically paced canine hearts in vivo.

    PubMed

    Costet, Alexandre; Provost, Jean; Gambhir, Alok; Bobkov, Yevgeniy; Danilo, Peter; Boink, Gerard J J; Rosen, Michael R; Konofagou, Elisa E

    2014-01-01

    Electromechanical wave imaging (EWI) has been show capable of directly and entirely non-invasively mapping the trans mural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability of localizing electronic and, for the first time, biological pacing locations in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR) and idioventricular rhythms occurring in dogs with complete heart block instrumented with electronic and biologic pacemakers (EPM and BPM respectively). After atrioventricular node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n = 4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n = 2). EWI was performed trans thoracically during NSR, BPM and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/s. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison indicated that EWI was repeatable and reliable. These findings thus indicate the potential for EWI to serve as a simple, non-invasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Taurine supplementation improves economy of movement in the cycle test independently of the detrimental effects of ethanol.

    PubMed

    Paulucio, Dailson; Costa, Bruno M; Santos, Caleb G M; Nogueira, Fernando; Koch, Alexander; Machado, Marco; Velasques, Bruna; Ribeiro, Pedro; Pompeu, Fernando Ams

    2017-12-01

    Taurine (TA) ingestion has been touted as blunting the deleterious effects of ethanol (ET) ingestion on motor performance. This study investigated the effects of ingestion of 0.6 mL·kg -1 of ET, 6 grams of TA, and ethanol in combination with taurine (ET+TA) on economy of movement (EM) and heart rate (HR). Nine volunteers, five female (22 ± 3 years) and four male (26 ± 5 years), participated in a study that used a counterbalanced experimental design. EM and HR were measured for 6 min while the subjects were pedalling at a fixed load 10% below the anaerobic threshold. The blood alcohol concentration (BAC) was similar between ET and ET+TA treatments at 30 min after ingestion and after exercise (12.3 mmol·L -1 vs. 13.7 mmol·L -1 , and 9.7 mmol • L -1 vs 10.9 mmol·L -1 , respectively). EM was significantly different among treatments, with lower mL·W -1 following ingestion of TA (-7.1%, p<0.001) than placebo and ET+TA (-2.45%, p=0.001) compared to ET. HR (bpm) was significantly (p<0.05) higher for ET (137 ± 14 bpm) than the other three treatments (placebo = 129 ± 14 bpm; TA = 127 ± 11 bpm; TA+ET = 133 ± 12 and ET = 137 ± 14 bpm). Taurine improved EM when compared to placebo or ET, and reduced HR when compared to ET. The combination of ET+TA also enhanced EM compared to placebo, and reduced HR in comparison to ET alone. Therefore, these findings indicate that taurine improves EM and counteracts ethanol-induced increases in HR during submaximal exercise.

  6. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  7. Heart rate and outcome in heart failure with reduced ejection fraction: Differences between atrial fibrillation and sinus rhythm-A CIBIS II analysis.

    PubMed

    Mulder, Bart A; Damman, Kevin; Van Veldhuisen, Dirk J; Van Gelder, Isabelle C; Rienstra, Michiel

    2017-09-01

    Heart rate has been associated with prognosis in patients with heart failure with reduced ejection fraction (HFREF) and sinus rhythm; whether this also holds true in patients with atrial fibrillation (AF) is unknown. To evaluate cardiac rhythm and baseline heart rate and the influence of outcome in patients with HFREF enrolled in the Cardiac Insufficiency Bisoprolol Study II. In total, 2539 patients were stratified according to their baseline heart rhythm (AF or sinus rhythm) and into quartiles of heart rate (≤70 bpm, 71-78 bpm, 79-90 bpm, and >90 bpm). The primary outcome was all-cause mortality. Mean follow-up was 1.3 years. Mean age was 61 years, mean left ventricular ejection fraction was 28%, and 80% were male. A total of 521 (21%) patients had AF at baseline. The risk associated with all-cause mortality for each 5 bpm increase in heart rate in patients with sinus rhythm (hazard ratio [HR]: 1.06, 95% confidence interval [CI]: 1.01-1.11, P = 0.012) was significantly different from those with AF (HR: 1.00, 95% CI: 0.94-1.07, P = 0.90, P for interaction = 0.041). The risk associated with higher heart rate in sinus rhythm was primarily attributable to excess risk in the highest quartile (HR: 1.64, 95% CI: 1.18-2.30, P = 0.003). Allocation to bisoprolol did not modify the interaction between heart rate, rhythm and outcome. In HFREF patients with AF, a higher heart rate is not associated with increased event rates in contrast to HFREF patients with sinus rhythm. © 2017 Wiley Periodicals, Inc.

  8. Attenuated Heart Rate Recovery After Exercise Testing and Risk of Incident Hypertension in Men.

    PubMed

    Jae, Sae Young; Bunsawat, Kanokwan; Fadel, Paul J; Fernhall, Bo; Choi, Yoon-Ho; Park, Jeong Bae; Franklin, Barry A

    2016-09-01

    Although attenuated heart rate recovery (HRR) and reduced heart rate (HR) reserve to maximal exercise testing are associated with adverse cardiovascular outcomes, their relation to incident hypertension in healthy normotensive populations is unclear. We examined the hypothesis that both attenuated HRR and reduced HR reserve to exercise testing are associated with incident hypertension in men. A total of 1,855 participants were selected comprising of healthy, initially normotensive men who underwent peak or symptom-limited treadmill testing at baseline. HRR was calculated as the difference between peak HR during exercise testing and the HR at 2 minutes after exercise cessation. HR reserve was calculated as the percentage of HR reserve (peak HR - resting HR)/(220 - age - resting HR) × 100. During an average 4-year follow-up, 179 (9.6%) men developed hypertension. Incident hypertension was associated with HRR quartiles (Q1 (<42 (bpm)) 12.5%, Q2 (43-49 bpm) 8.5%, Q3 (50-56 bpm) 9.3%, and Q4 (>57 bpm) 8.3%; P = 0.05 for trend). The relative risk (RR) of the incident hypertension in the slowest HRR quartile vs. the fastest HRR quartile was 1.78 (95% confidence interval (CI): 1.14-2.78) after adjustment for confounders. Every 1 bpm increment in HRR was associated with a 2% (RR 0.98, 95% CI: 0.97-0.99) lower risk of incident hypertension after adjusting for potential confounders. In contrast, reduced HR reserve did not predict the risk of incident hypertension. Slow HRR after exercise testing is independently associated with the development of hypertension in healthy normotensive men. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Assessing the utility of bipolar membranes for use in photoelectrochemical water-splitting cells.

    PubMed

    Vargas-Barbosa, Nella M; Geise, Geoffrey M; Hickner, Michael A; Mallouk, Thomas E

    2014-11-01

    Membranes are important in water-splitting solar cells because they prevent crossover of hydrogen and oxygen. Here, bipolar membranes (BPMs) were tested as separators in water electrolysis cells. Steady-state membrane and solution resistances, electrode overpotentials, and pH gradients were measured at current densities relevant to solar photoelectrolysis. Under forward bias conditions, electrodialysis of phosphate buffer ions creates a pH gradient across a BPM. Under reverse bias, the BPM can maintain a constant buffer pH on both sides of the cell, but a large membrane potential develops. Thus, the BPM does not present a viable solution for electrolysis in buffered electrolytes. However, the membrane potential is minimized when the anode and cathode compartments of the cell contain strongly basic and acidic electrolytes, respectively. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Hemodynamic variables predict outcome of emergency thoracotomy in the pediatric trauma population.

    PubMed

    Wyrick, Deidre L; Dassinger, Melvin S; Bozeman, Andrew P; Porter, Austin; Maxson, R Todd

    2014-09-01

    Limited data exist regarding indications for resuscitative emergency thoracotomy (ETR) in the pediatric population. We attempt to define the presenting hemodynamic parameters that predict survival for pediatric patients undergoing ETR. We reviewed all pediatric patients (age <18years), entered into the National Trauma Data Bank from 2007 to 2010, who underwent ETR within one hour of ED arrival. Mechanism of injury and hemodynamics were analyzed using Chi squared and Wilcoxon tests. 316 children (70 blunt, 240 penetrating) underwent ETR, 31% (98/316) survived to discharge. Less than 5% of patients survived when presenting SBP was ≤50mmHg or heart rate was ≤70bpm. For blunt injuries there were no survivors with a pulse ≤80bpm or SBP ≤60mmHg. When survivors were compared to nonsurvivors, blood pressure, pulse, and injury type were statistically significant when treated as independent variables and in a logistic regression model. When ETR was performed for SBP ≤50mmHg or for heart rate ≤70bpm less than 5% of patients survived. There were no survivors of blunt trauma when SBP was ≤60mmHg or pulse was ≤80bpm. This review suggests that ETR may have limited benefit in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor

    PubMed Central

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L.; Minassian, Arpi

    2016-01-01

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. PMID:27138818

  12. Brevibacillus laterosporus strain BPM3, a potential biocontrol agent isolated from a natural hot water spring of Assam, India.

    PubMed

    Saikia, R; Gogoi, D K; Mazumder, S; Yadav, A; Sarma, R K; Bora, T C; Gogoi, B K

    2011-03-20

    A bacterial strain designated as BPM3 isolated from mud of a natural hot water spring of Nambar Wild Life Sanctuary, Assam, India, strongly inhibited growth of phytopathogenic fungi (Fusarium oxysporum f. sp. ciceri, F. semitectum, Magnaporthe grisea and Rhizoctonia oryzae) and gram-positive bacterium (Staphylococcus aureus). The maximum growth and antagonistic activity was recorded at 30°C, pH 8.5 when starch and peptone were amended as carbon and nitrogen sources, respectively. In greenhouse experiment, this bacterium (BPM3) suppressed blast disease of rice by 30-67% and protected the weight loss by 35-56.5%. The maximum disease protection (67%) and weight loss protection (56.5%) were recorded when the bacterium was applied before 2 days of the pathogen inoculation. Antifungal and antibacterial compounds were isolated from the bacterium which also inhibited the growth of these targeted pathogens. The compounds were purified and on spectroscopic analysis of a purified fraction having R(f) 0.22 which showed strong antifungal and antibacterial activity indicated the presence of C-H, carbonyl group, dimethyl group, -CH(2) and methyl group. The bacterium was characterized by morphological, biochemical and molecular approaches and confirmed that the strain BPM3 is Brevibacillus laterosporus. Copyright © 2010 Elsevier GmbH. All rights reserved.

  13. Doppler radar sensing of fish physiological motion

    NASA Astrophysics Data System (ADS)

    Hafner, Noah

    The monitoring vital of signs for fish is critical for advancing the study of trophic and energetic strategies, distributions and behavior, environmental impact, and aquaculture approaches. Presented here is a new approach for monitoring fish metabolic state without the trauma and stress associated with capture, surgical ECG, or other implanted sensing systems. Original research contributions include analysis for radar operation under water, development of radar systems for aquatic operation, and application of these systems to non invasively sense the heart and gill motion of fish. Tilapia and Sturgeon were studied to test the efficacy across varied fish body shapes and sizes, ranging from 0.1 to 1.3m in snout to tail length. Monitoring experiments were conducted with eleven tilapia and three sturgeons to assess activity level participated in these experiments, the results from which include activity level monitoring (tilapia: still or fidgeting 94% of time observed), ventilation rate (tilapia: 42 bpm, sturgeon: 145 bpm), and heart rate (tilapia: 41 bpm, sturgeon: 35 bpm). Bland-Altman analysis of radar and ECG measured heart rate indicate agreement between the two measurement techniques and the suitability of radar as an alternative to ECG. The initial steps for developing a system for practical application is also presented including designs for radar system miniaturization and discussion on further characterization steps with less constrained environments.

  14. Revisiting the relationship between exercise heart rate and music tempo preference.

    PubMed

    Karageorghis, Costas I; Jones, Leighton; Priest, David-Lee; Akers, Rose I; Clarke, Adam; Perry, Jennifer M; Reddick, Benjamin T; Bishop, Daniel T; Lim, Harry B T

    2011-06-01

    In the present study, we investigated a hypothesized quartic relationship (meaning three inflection points) between exercise heart rate (HR) and preferred music tempo. Initial theoretical predictions suggested a positive linear relationship (Iwanaga, 1995a, 1995b); however, recent experimental work has shown that as exercise HR increases, step changes and plateaus that punctuate the profile of music tempo preference may occur (Karageorghis, Jones, & Stuart, 2008). Tempi bands consisted of slow (95-100 bpm), medium (115-120 bpm), fast (135-140 bpm), and very fast (155-160 bpm) music. Twenty-eight active undergraduate students cycled at exercise intensities representing 40, 50, 60, 70, 80, and 90% of their maximal HR reserve while their music preference was assessed using a 10-point scale. The Exercise Intensity x Music Tempo interaction was significant, F(6.16, 160.05) = 7.08, p < .001, 7,2 = .21, as was the test for both cubic and quartic trajectories in the exercise HR-preferred-music-tempo relationship (p < .001). Whereas slow tempo music was not preferred at any exercise intensity, preference for fast tempo increased, relative to medium and very fast tempo music, as exercise intensity increased. The implications for the prescription of music in exercise and physical activity contexts are discussed.

  15. Adhesion of glucosyltransferase phase variants to Streptococcus gordonii bacterium-glucan substrata may involve lipoteichoic acid.

    PubMed

    Vickerman, M M; Jones, G W

    1992-10-01

    Growing Streptococcus gordonii Spp+ phase variants, which have normal levels of glucosyltransferase (GTF) activity, use sucrose to promote their accumulation on surfaces by forming a cohesive bacterium-insoluble glucan polymer mass (BPM). Spp- phase variants, which have lower levels of GTF activity, do not form BPMs and do not remain in BPMs formed by Spp+ cells when grown in mixed cultures. To test the hypothesis that segregation of attached Spp+ and unattached Spp- cells was due to differences in adhesiveness, adhesion between washed, [3H]thymidine-labeled cells and preformed BPM substrata was measured. Unexpectedly, the results showed that cells of both phenotypes, as well as GTF-negative cells, attached equally well to preformed BPMs, indicating that attachment to BPMs was independent of cell surface GTF activity. Initial characterization of this binding interaction suggested that a protease-sensitive component on the washed cells may be binding to lipoteichoic acids sequestered in the BPM, since exogenous lipoteichoic acid inhibited adhesion. Surprisingly, the adhesion of both Spp+ and Spp- cells was markedly inhibited in the presence of sucrose, which also released lipoteichoic acid from the BPM. These in vitro findings suggest that, in vivo, sucrose and lipoteichoic acid may modify dental plaque development by enhancing or inhibiting the attachment of additional bacteria.

  16. One elevated bladder pressure measurement may not be enough to diagnose abdominal compartment syndrome.

    PubMed

    Young, Andrew Joseph; Weber, William; Wolfe, Luke; Ivatury, Rao R; Duane, Therese Marie

    2013-02-01

    Bladder pressure measurements (BPMs) are considered a key component in the diagnosis of abdominal compartment syndrome (ACS). The purpose of this observational review was to determine risk factors of ACS and associated mortality with particular focus on the role of BPM. A retrospective trauma registry and chart review was performed on trauma patients from January 2003 through December 2010. Comparisons were made between patients with and without ACS. There were 3172 patients included in the study of whom 46 had ACS. Patients with ACS were younger, more severely injured, with longer lengths of stay. Logistic regression determined Injury Severity Score (ISS) and urinary catheter days as independent predictors of ACS, whereas independent predictors of mortality included age, ISS, and ACS. Subset analysis demonstrated no association between BPM 20 mmHg or greater and diagnosis of ACS versus no ACS. Logistic regression indicated independent predictors of mortality were number of BPM 20 mmHg or greater and age. Patients with ACS are more severely injured with worse outcomes. An isolated BPM 20 mmHg or greater was not associated with ACS and may be inadequate to independently diagnose ACS. These findings suggest the need for repeat measurements with early intervention if they remain elevated in an effort to decrease mortality associated with ACS.

  17. Adhesion of glucosyltransferase phase variants to Streptococcus gordonii bacterium-glucan substrata may involve lipoteichoic acid.

    PubMed Central

    Vickerman, M M; Jones, G W

    1992-01-01

    Growing Streptococcus gordonii Spp+ phase variants, which have normal levels of glucosyltransferase (GTF) activity, use sucrose to promote their accumulation on surfaces by forming a cohesive bacterium-insoluble glucan polymer mass (BPM). Spp- phase variants, which have lower levels of GTF activity, do not form BPMs and do not remain in BPMs formed by Spp+ cells when grown in mixed cultures. To test the hypothesis that segregation of attached Spp+ and unattached Spp- cells was due to differences in adhesiveness, adhesion between washed, [3H]thymidine-labeled cells and preformed BPM substrata was measured. Unexpectedly, the results showed that cells of both phenotypes, as well as GTF-negative cells, attached equally well to preformed BPMs, indicating that attachment to BPMs was independent of cell surface GTF activity. Initial characterization of this binding interaction suggested that a protease-sensitive component on the washed cells may be binding to lipoteichoic acids sequestered in the BPM, since exogenous lipoteichoic acid inhibited adhesion. Surprisingly, the adhesion of both Spp+ and Spp- cells was markedly inhibited in the presence of sucrose, which also released lipoteichoic acid from the BPM. These in vitro findings suggest that, in vivo, sucrose and lipoteichoic acid may modify dental plaque development by enhancing or inhibiting the attachment of additional bacteria. PMID:1398940

  18. Comparison of devices for newborn ventilation in the delivery room.

    PubMed

    Szyld, Edgardo; Aguilar, Adriana; Musante, Gabriel A; Vain, Nestor; Prudent, Luis; Fabres, Jorge; Carlo, Waldemar A

    2014-08-01

    To evaluate the effectiveness and safety of a T-piece resuscitator compared with a self-inflating bag for providing mask ventilation to newborns at birth. Newborns at ≥26 weeks gestational age receiving positive-pressure ventilation at birth were included in this multicenter cluster-randomized 2-period crossover trial. Positive-pressure ventilation was provided with either a self-inflating bag (self-inflating bag group) with or without a positive end-expiratory pressure valve or a T-piece with a positive end-expiratory pressure valve (T-piece group). Delivery room management followed American Academy of Pediatrics and International Liaison Committee on Resuscitation guidelines. The primary outcome was the proportion of newborns with heart rate (HR)≥100 bpm at 2 minutes after birth. A total of 1027 newborns were included. There was no statistically significant difference in the incidence of HR≥100 bpm at 2 minutes after birth between the T-piece and self-inflating bag groups: 94% (479 of 511) and 90% (466 of 516), respectively (OR, 0.65; 95% CI, 0.41-1.05; P=.08). A total of 86 newborns (17%) in the T-piece group and 134 newborns (26%) in the self-inflating bag group were intubated in the delivery room (OR, 0.58; 95% CI, 0.4-0.8; P=.002). The mean±SD maximum positive inspiratory pressure was 26±2 cm H2O in the T-piece group vs 28±5 cm H2O in the self-inflating bag group (P<.001). Air leaks, use of drugs/chest compressions, mortality, and days on mechanical ventilation did not differ significantly between groups. There was no difference between the T-piece resuscitator and a self-inflating bag in achieving an HR of ≥100 bpm at 2 minutes in newborns≥26 weeks gestational age resuscitated at birth. However, use of the T-piece decreased the intubation rate and the maximum pressures applied. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Cardiac Repolarization Instability during Psychological Stress in Patients with Ventricular Arrhythmias

    PubMed Central

    Abisse, Saddam S.; Lampert, Rachel; Burg, Mattew; Soufer, Robert; Shusterman, Vladimir

    2011-01-01

    Introduction Changes in the autonomic nervous system activity (ANS) are a major trigger of life-threatening ventricular tachyarrhythmias (VTA). Mental arithmetic, a condition administered in a laboratory setting, can provide insight into the ANS effects on cardiac physiology. We examined the responses of cardiac repolarization to laboratory-induced psychological stressors in patients with implantable cardioverter defibrillators (ICDs) with the objective of identifying the indices that differentiate patients with and without subsequent VTA in follow-up. Methods Continuous ECG signals were recorded using 3 standard bipolar (Holter) leads in 56 patients (age: 63.6±11.9, female: 12%, LVEF: 32.3±11) with ICDs during mental arithmetic. The patients were separated into those with subsequent VTA during 3–4 years of follow-up (Group 1: N=9 pts) and those without VTA (Group 2: N=47 pts). Changes in repolarization (QT-interval, mean T-wave amplitude (Tamp), and T-wave area (Tarea) were analyzed during 5min of baseline, stress and recovery. The temporal instability of Tamp and Tarea was examined using the range (Δ) and variance (σ2) of beat-to-beat variations of the corresponding parameters. Results There were no significant differences in HR between the two groups at baseline (61 vs. 63 bpm, p=0.97), during stress (64 vs. 65 bpm, p=0.40), and recovery (62 vs. 61 bpm, p= 0.88). However, during mental stress and post-stress recovery ΔTamp was almost 2-fold greater in Group 1 compared with Group 2 (111 (57–203)) vs. 68 (44–94) μV p=0.04, respectively). Changes in QT-intervals were also greater in Group 1 compared with Group 2 (p=0.02). Conclusion Among patients with ICDs, changes of T-wave amplitude after psychological stress were greater in those with subsequent arrhythmic events. This might signal proarrhythmic repolarization response and help identify patients who would benefit the most from ICD implantation and proactive management. PMID:21920534

  20. Advances in the management of heart failure: the role of ivabradine

    PubMed Central

    Müller-Werdan, Ursula; Stöckl, Georg; Werdan, Karl

    2016-01-01

    A high resting heart rate (≥70–75 b.p.m.) is a risk factor for patients with heart failure (HF) with reduced ejection fraction (EF), probably in the sense of accelerated atherosclerosis, with an increased morbidity and mortality. Beta-blockers not only reduce heart rate but also have negative inotropic and blood pressure-lowering effects, and therefore, in many patients, they cannot be given in the recommended dose. Ivabradine specifically inhibits the pacemaker current (funny current, If) of the sinoatrial node cells, resulting in therapeutic heart rate lowering without any negative inotropic and blood pressure-lowering effect. According to the European Society of Cardiology guidelines, ivabradine should be considered to reduce the risk of HF hospitalization and cardiovascular death in symptomatic patients with a reduced left ventricular EF ≤35% and sinus rhythm ≥70 b.p.m. despite treatment with an evidence-based dose of beta-blocker or a dose below the recommended dose (recommendation class “IIa” = weight of evidence/opinion is in favor of usefulness/efficacy: “should be considered”; level of evidence “B” = data derived from a single randomized clinical trial or large nonrandomized studies). Using a heart rate cutoff of ≥ 75 b.p.m., as licensed by the European Medicines Agency, treatment with ivabradine 5–7.5 mg b.i.d. reduces cardiovascular mortality by 17%, HF mortality by 39% and HF hospitalization rate by 30%. A high resting heart rate is not only a risk factor in HF with reduced EF but also at least a risk marker in HF with preserved EF, in acute HF and also in special forms of HF. In this review, we discuss the proven role of ivabradine in the validated indication “HF with reduced EF” together with interesting preliminary findings, and the potential role of ivabradine in further, specific forms of HF. PMID:27895488

  1. Geographical variations in the prevalence and management of cardiovascular risk factors in outpatients with CAD: Data from the contemporary CLARIFY registry.

    PubMed

    Ferrari, Roberto; Ford, Ian; Greenlaw, Nicola; Tardif, Jean-Claude; Tendera, Michal; Abergel, Hélène; Fox, Kim; Hu, Dayi; Shalnova, Svetlana; Steg, Ph Gabriel

    2015-08-01

    To determine the current prevalence and control of major cardiovascular risk factors in stable CAD outpatients worldwide. We analysed variations in cardiovascular risk factors in stable CAD outpatients from CLARIFY, a 5-year observational longitudinal cohort study, in seven geographical zones (Western/Central Europe; Canada/South Africa/Australia/UK; Eastern Europe; Central/South America; Middle East; East Asia; and India). Patient presentation (N=32,954, mean age 64.2 years, 78% male) varied between zones, as did prevalence of risk factors (all p < 0.0001). Obesity ranged from 20% (East Asia) to 42% (Middle East), raised blood pressure from 28% (Central/South America and East Asia) to 48% (Eastern Europe), raised LDL cholesterol from 24% (Canada/South Africa/Australia/UK) to 65% (Eastern Europe), elevated heart rate (≥70 bpm) from 38% (Western/Central Europe) to 78% (India), diabetes from 17% (Eastern Europe) to 60% (Middle East), and smoking from 6% (Central/South America) to 19% (Eastern Europe). Aspirin and lipid-lowering drugs were widely used everywhere (≥84% and ≥88%, respectively). Rates of risk factor control varied geographically (all p < 0.0001). Rate of controlled blood pressure in hypertension varied from 47% (Eastern Europe) to 66% (Central/South America), glucose control in diabetes from 23% (India) to 51% (Western/Central Europe and East Asia), controlled LDL cholesterol and dyslipidaemia from 32% (Eastern Europe) to 75% (Canada/South Africa/Australia/UK), heart rate <70 bpm from 22% (India) to 62% (Western/Central Europe), and heart rate ≤60 bpm in angina patients from 2% (India) to 29% (Canada/South Africa/Australia/UK and Central/South America). Prevalence and control of major cardiovascular risk factors in stable CAD vary markedly worldwide. Many stable CAD outpatients are being treated suboptimally. © The European Society of Cardiology 2014.

  2. Real-life indications to ivabradine treatment for heart rate optimization in patients with chronic systolic heart failure.

    PubMed

    Tondi, Lara; Fragasso, Gabriele; Spoladore, Roberto; Pinto, Giuseppe; Gemma, Marco; Slavich, Massimo; Godino, Cosmo; Salerno, Anna; Montanaro, Claudia; Margonato, Alberto

    2018-05-11

    : Ivabradine is a selective and specific inhibitor of If current. With its pure negative chronotropic action, it is recommended by European Society of Cardiology and American College of Cardiology/American Heart Association guidelines in symptomatic heart failure patients (NYHA ≥ 2) with ejection fraction 35% or less, sinus rhythm and heart rate (HR) at least 70 bpm, despite maximally titrated β-blocker therapy. Data supporting this indication mainly derive from the SHIFT study, in which ivabradine reduced the combined endpoint of mortality and hospitalization, despite the fact that only 26% of patients enrolled were on optimal β-blocker doses. The aim of the present analysis is to establish the real-life eligibility for ivabradine in a population of patients with systolic heart failure, regularly attending a single heart failure clinic and treated according to guideline-directed medical therapy (GDMT). The clinical cards of 308 patients with heart failure with reduced ejection fraction (HFrEF) through a 68-month period of observation were retrospectively analyzed. GDMT, including β-blocker up-titration to maximal tolerated dose, was implemented during consecutive visits at variable intervals. Demographic, clinical and echocardiographic data were collected at each visit, together with 12-leads ECG and N-terminal pro-B-type natriuretic peptide levels. Out of 308 analyzed HFrEF patients, 220 (71%) were on effective β-blocker therapy, up-titrated to effective/maximal tolerated dose (55 ± 28% of maximal dose) (HR 67 ± 10 bpm). Among the remaining 88 patients, 10 (3.2%) were on maximally tolerated β blocker and ivabradine; 21 patients (6.8%), despite being on maximal tolerated β-blocker dose, had still HR ≥70 bpm, ejection fraction 35% or less and were symptomatic NYHA ≥2, being therefore eligible for ivabradine treatment. The remaining 57 (18%) patients were not on β blocker due to either intolerance or major contraindications. Among them, 13 (4%) were taking ivabradine alone. Of the final 44 (14%) patients, 27 (9%) showed an inadequate HR control (74 ± 6 bpm). Of these, only eight (3%) patients resulted to be eligible for ivabradine introduction according to HR and ejection fraction parameters. Overall ivabradine was indicated in 52 patients (16.8%) out of 308 enrolled.In conclusion, in a carefully managed population of patients with moderate and stable HFrEF, in which optimal GDMT is properly attained, indication to ivabradine treatment is around 17%.

  3. Lattice Calibration with Turn-By-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xiaobiao; /SLAC; Sebek, James

    2012-07-02

    Turn-by-turn beam position monitor (BPM) data from multiple BPMs are fitted with a tracking code to calibrate magnet strengths in a manner similar to the well known LOCO code. Simulation shows that this turn-by-turn method can be a quick and efficient way for optics calibration. The method is applicable to both linacs and ring accelerators. Experimental results for a section of the SPEAR3 ring is also shown.

  4. Formic acid acting as an efficient oxygen scavenger in four-electron reduction of oxygen catalyzed by a heterodinuclear iridium-ruthenium complex in water.

    PubMed

    Fukuzumi, Shunichi; Kobayashi, Takeshi; Suenobu, Tomoyoshi

    2010-09-01

    A heterodinuclear iridium-ruthenium complex [Ir(III)(Cp*)(H(2)O)(bpm)Ru(II)(bpy)(2)](SO(4))(2) (Cp* = eta(5)-pentamethyl-cyclopentadienyl, bpm = 2,2'-bipyrimidine, bpy = 2,2'-bipyridine) acts as an effective catalyst for removal of dissolved O(2) by the four-electron reduction of O(2) with formic acid in water at an ambient temperature.

  5. Beam Position Monitoring in the CSU Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Einstein, Joshua; Vankeuren, Max; Watras, Stephen

    2014-03-01

    A Beam Position Monitoring (BPM) system is an integral part of an accelerator beamline, and modern accelerators can take advantage of newer technologies and designs when creating a BPM system. The Colorado State University (CSU) Accelerator Facility will include four stripline detectors mounted around the beamline, a low-noise analog front-end, and digitization and interface circuitry. The design will support a sampling rate greater than 10 Hz and sub-100 μm accuracy.

  6. Constraining the physics of carbon crystallization through pulsations of a massive DAV BPM37093

    NASA Astrophysics Data System (ADS)

    Nitta, Atsuko; Kepler, S. O.; Chené, André-Nicolas; Koester, D.; Provencal, J. L.; Kleinmani, S. J.; Sullivan, D. J.; Chote, Paul; Sefako, Ramotholo; Kanaan, Antonio; Romero, Alejandra; Corti, Mariela; Kilic, Mukremin; Montgomery, M. H.; Winget, D. E.

    We are trying to reduce the largest uncertainties in using white dwarf stars as Galactic chronometers by understanding the details of carbon crystalliazation that currently result in a 1-2 Gyr uncertainty in the ages of the oldest white dwarf stars. We expect the coolest white dwarf stars to have crystallized interiors, but theory also predicts hotter white dwarf stars, if they are massive enough, will also have some core crystallization. BPM 37093 is the first discovered of only a handful of known massive white dwarf stars that are also pulsating DAV, or ZZ Ceti, variables. Our approach is to use the pulsations to constrain the core composition and amount of crystallization. Here we report our analysis of 4 hours of continuous time series spectroscopy of BPM 37093 with Gemini South combined with simultaneous time-series photometry from Mt. John (New Zealand), SAAO, PROMPT, and Complejo Astronomico El Leoncito (CASLEO, Argentina).

  7. Constrained independent component analysis approach to nonobtrusive pulse rate measurements

    NASA Astrophysics Data System (ADS)

    Tsouri, Gill R.; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K.

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  8. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-06-22

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test themore » digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.« less

  9. Best practicable means (BPM) and as low as reasonably practicable (ALARP) in action at Sellafield.

    PubMed

    Morley, Bob

    2004-03-01

    Operators within the UK nuclear industry are required to employ 'best practicable means' (BPM) to control and minimise radioactive discharges. The requirement for the use of BPM is in order to ensure that doses from discharges are as low as reasonably practicable (ALARP). This facet is increasingly becoming the principal feature of discharge authorisations issued by the Environment Agencies under the Radioactive Substances Act, 1993 (RSA 93), which are enforceable by law. It is important to state at the outset, however, that scientific assessments to date indicate that there are no expectations of environmental harm from authorised discharges, even where those discharges have historically been up to two orders of magnitude higher than current levels. There is also no evidence to indicate that foreseeable future discharges from the Sellafield site will make any contribution to environmental harm.

  10. Effect of the type of ion exchange membrane on performance, ion transport, and pH in biocatalyzed electrolysis of wastewater.

    PubMed

    Rozendal, R A; Sleutels, T H J A; Hamelers, H V M; Buisman, C J N

    2008-01-01

    Previous studies have shown that the application of cation exchange membranes (CEMs) in bioelectrochemical systems running on wastewater can cause operational problems. In this paper the effect of alternative types of ion exchange membrane is studied in biocatalyzed electrolysis cells. Four types of ion exchange membranes are used: (i) a CEM, (ii) an anion exchange membrane (AEM), (iii) a bipolar membrane (BPM), and (iv) a charge mosaic membrane (CMM). With respect to the electrochemical performance of the four biocatalyzed electrolysis configurations, the ion exchange membranes are rated in the order AEM > CEM > CMM > BPM. However, with respect to the transport numbers for protons and/or hydroxyl ions (t(H/OH)) and the ability to prevent pH increase in the cathode chamber, the ion exchange membranes are rated in the order BPM > AEM > CMM > CEM.

  11. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    PubMed

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  12. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    PubMed

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  13. BPM analysis of all-optical fiber interferometric sensor based on a U-shape microcavity

    NASA Astrophysics Data System (ADS)

    Wu, Hongbin; Yuan, Lei; Wang, Sumei; Zhao, Longjiang; Cao, Zhitao

    2014-02-01

    Reflectivity spectrum of beam propagation method (BPM), for the first time to the best of our knowledge, is realized and utilized to model all-optical fiber interferometric sensor formed by a U-shape microcavity embedded in a single mode optical fiber and illustrate the principle of sensor structures varied by the length and the depth of U-shape microcavity. BPM analysis gives a constructive guideline to get a high interferometric fringe visibility which is most important for sensing application. The simulated results are completely in agreement with the interferometric sensor principle of Fabry-Perot interferometer (FPI) theory. With the conclusion of FPI sensor, refractive index (RI) sensitivity and temperature sensitivity are then simulated and obtained as 1049+/-5.2nm/RIU (refractive index unit) within RI range of solutions and 1.04+/-0.03pm/°C respectively.

  14. Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretched-wire RF measurements

    NASA Astrophysics Data System (ADS)

    Zorzetti, Silvia; Fanucci, Luca; Galindo Muñoz, Natalia; Wendt, Manfred

    2015-09-01

    The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-μm regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method.

  15. Constrained independent component analysis approach to nonobtrusive pulse rate measurements.

    PubMed

    Tsouri, Gill R; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  16. Performance of a high resolution cavity beam position monitor system

    NASA Astrophysics Data System (ADS)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  17. Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

    NASA Astrophysics Data System (ADS)

    Petrenko, A. V.; Valishev, A. A.; Lebedev, V. A.

    2011-09-01

    Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA) technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM) as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

  18. Mechanism linking T-wave alternans to the genesis of cardiac fibrillation.

    PubMed

    Pastore, J M; Girouard, S D; Laurita, K R; Akar, F G; Rosenbaum, D S

    1999-03-16

    Although T-wave alternans has been closely associated with vulnerability to ventricular arrhythmias, the cellular processes underlying T-wave alternans and their role, if any, in the mechanism of reentry remain unclear. -T-wave alternans on the surface ECG was elicited in 8 Langendorff-perfused guinea pig hearts during fixed-rate pacing while action potentials were recorded simultaneously from 128 epicardial sites with voltage-sensitive dyes. Alternans of the repolarization phase of the action potential was observed above a critical threshold heart rate (HR) (209+/-46 bpm) that was significantly lower (by 57+/-36 bpm) than the HR threshold for alternation of action potential depolarization. The magnitude (range, 2.7 to 47.0 mV) and HR threshold (range, 171 to 272 bpm) of repolarization alternans varied substantially between cells across the epicardial surface. T-wave alternans on the surface ECG was explained primarily by beat-to-beat alternation in the time course of cellular repolarization. Above a critical HR, membrane repolarization alternated with the opposite phase between neighboring cells (ie, discordant alternans), creating large spatial gradients of repolarization. In the presence of discordant alternans, a small acceleration of pacing cycle length produced a characteristic sequence of events: (1) unidirectional block of an impulse propagating against steep gradients of repolarization, (2) reentrant propagation, and (3) the initiation of ventricular fibrillation. Repolarization alternans at the level of the single cell accounts for T-wave alternans on the surface ECG. Discordant alternans produces spatial gradients of repolarization of sufficient magnitude to cause unidirectional block and reentrant ventricular fibrillation. These data establish a mechanism linking T-wave alternans of the ECG to the pathogenesis of sudden cardiac death.

  19. The Effect of Physical Resistance Training on Baroreflex Sensitivity of Hypertensive Rats.

    PubMed

    Gomes, Moisés Felipe Pereira; Borges, Mariana Eiras; Rossi, Vitor de Almeida; Moura, Elizabeth de Orleans C de; Medeiros, Alessandra

    2017-01-01

    Baroreceptors act as regulators of blood pressure (BP); however, its sensitivity is impaired in hypertensive patients. Among the recommendations for BP reduction, exercise training has become an important adjuvant therapy in this population. However, there are many doubts about the effects of resistance exercise training in this population. To evaluate the effect of resistance exercise training on BP and baroreceptor sensitivity in spontaneously hypertensive rats (SHR). Rats SHR (n = 16) and Wistar (n = 16) at 8 weeks of age, at the beginning of the experiment, were randomly divided into 4 groups: sedentary control (CS, n = 8); trained control (CT, n = 8); sedentary SHR (HS, n = 8) and trained SHR (HT, n = 8). Resistance exercise training was performed in a stairmaster-type equipment (1.1 × 0.18 m, 2 cm between the steps, 80° incline) with weights attached to their tails, (5 days/week, 8 weeks). Baroreceptor reflex control of heart rate (HR) was tested by loading/unloading of baroreceptors with phenylephrine and sodium nitroprusside. Resistance exercise training increased the soleus muscle mass in SHR when compared to HS (HS 0.027 ± 0.002 g/mm and HT 0.056 ± 0.003 g/mm). Resistance exercise training did not alter BP. On the other hand, in relation to baroreflex sensitivity, bradycardic response was improved in the TH group when compared to HS (HS -1.3 ± 0.1 bpm/mmHg and HT -2.6 ± 0.2 bpm/mmHg) although tachycardia response was not altered by resistance exercise (CS -3.3 ± 0.2 bpm/mmHg, CT -3.3 ± 0.1 bpm/mmHg, HS -1.47 ± 0.06 bpm/mmHg and HT -1.6 ± 0.1 bpm/mmHg). Resistance exercise training was able to promote improvements on baroreflex sensitivity of SHR rats, through the improvement of bradycardic response, despite not having reduced BP. Os barorreceptores atuam como reguladores da pressão arterial (PA); no entanto, sua sensibilidade encontra-se prejudicada em pacientes hipertensos. Dentre as recomendações para a redução da PA, o treinamento físico tem se tornado um importante adjunto na terapia dessa população. Porém, ainda há diversos questionamentos sobre os efeitos de treinamento físico resistido nessa população. Avaliar o efeito do treinamento físico resistido na PA e na sensibilidade de barorreceptores em ratos espontaneamente hipertensos (SHR). Ratos SHR (n = 16) e Wistar (n = 16) com 08 semanas de idade foram aleatoriamente divididos em 4 grupos: controle sedentário (CS, n = 8); controle treinado (CT, n = 8); SHR sedentário (HS, n = 8) e SHR treinado (HT, n = 8). O treinamento físico foi realizado em aparato com degraus (1,1 × 0,18 m, 2 cm entre os degraus, 80° inclinação) com peso fixado na cauda, (5 vezes por semana durante 8 semanas). O controle barorreflexo da frequência cardíaca (FC) foi testado com estímulos de fenilefrina e nitroprussiato de sódio. O treinamento resistido foi capaz de aumentar a massa muscular do sóleo em ratos SHR (HS 0,027 ± 0,002 g/mm e HT 0,056 ± 0,003 g/mm). Não houve alteração da PA com o treinamento. Por outro lado, houve melhora na resposta bradicárdica da sensibilidade barorreflexa no grupo HT (HS -1,3 ± 0,1 bpm/mmHg e HT -2,6 ± 0,2 bpm/mmHg), no entanto, a resposta taquicárdica não foi alterada pelo exercício resistido (CS -3,3 ± 0,2 bpm/mmHg, CT -3,3 ± 0,1 bpm/mmHg, HS -1,47 ± 0,06 e HT -1,6 ± 0,1). O exercício físico resistido foi capaz de otimizar a sensibilidade barorreflexa dos ratos SHR por meio da melhora à resposta bradicárdica, apesar de não alterar a PA.

  20. Heart Rate Responses to Autonomic Challenges in Obstructive Sleep Apnea

    PubMed Central

    Macey, Paul M.; Kumar, Rajesh; Woo, Mary A.; Yan-Go, Frisca L.; Harper, Ronald M.

    2013-01-01

    Obstructive sleep apnea (OSA) is accompanied by structural alterations and dysfunction in central autonomic regulatory regions, which may impair dynamic and static cardiovascular regulation, and contribute to other syndrome pathologies. Characterizing cardiovascular responses to autonomic challenges may provide insights into central nervous system impairments, including contributions by sex, since structural alterations are enhanced in OSA females over males. The objective was to assess heart rate responses in OSA versus healthy control subjects to autonomic challenges, and, separately, characterize female and male patterns. We studied 94 subjects, including 37 newly-diagnosed, untreated OSA patients (6 female, age mean±std: 52.1±8.1 years; 31 male aged 54.3±8.4 years), and 57 healthy control subjects (20 female, 50.5±8.1 years; 37 male, 45.6±9.2 years). We measured instantaneous heart rate with pulse oximetry during cold pressor, hand grip, and Valsalva maneuver challenges. All challenges elicited significant heart rate differences between OSA and control groups during and after challenges (repeated measures ANOVA, p<0.05). In post-hoc analyses, OSA females showed greater impairments than OSA males, which included: for cold pressor, lower initial increase (OSA vs. control: 9.5 vs. 7.3 bpm in females, 7.6 vs. 3.7 bpm in males), OSA delay to initial peak (2.5 s females/0.9 s males), slower mid-challenge rate-of-increase (OSA vs. control: −0.11 vs. 0.09 bpm/s in females, 0.03 vs. 0.06 bpm/s in males); for hand grip, lower initial peak (OSA vs. control: 2.6 vs. 4.6 bpm in females, 5.3 vs. 6.0 bpm in males); for Valsalva maneuver, lower Valsalva ratio (OSA vs. control: 1.14 vs. 1.30 in females, 1.29 vs. 1.34 in males), and OSA delay during phase II (0.68 s females/1.31 s males). Heart rate responses showed lower amplitude, delayed onset, and slower rate changes in OSA patients over healthy controls, and impairments may be more pronounced in females. The dysfunctions may reflect central injury in the syndrome, and suggest autonomic deficiencies that may contribute to further tissue and functional pathologies. PMID:24194842

  1. Coronary CT Angiography Incorporating Doppler-Guided Prospective ECG Gating in Patients with High Heart Rate: Comparison with Results of Traditional Prospective ECG Gating

    PubMed Central

    Li, Min; Yu, Bing-bing; Wu, Jian-hua; Xu, Lin; Sun, Gang

    2013-01-01

    Purpose As Doppler ultrasound has been proven to be an effective tool to predict and compress the optimal pulsing windows, we evaluated the effective dose and diagnostic accuracy of coronary CT angiography (CTA) incorporating Doppler-guided prospective electrocardiograph (ECG) gating, which presets pulsing windows according to Doppler analysis, in patients with a heart rate >65 bpm. Materials and Methods 119 patients with a heart rate >65 bpm who were scheduled for invasive coronary angiography were prospectively studied, and patients were randomly divided into traditional prospective (n = 61) and Doppler-guided prospective (n = 58) ECG gating groups. The exposure window of traditional prospective ECG gating was set at 30%–80% of the cardiac cycle. For the Doppler group, the length of diastasis was analyzed by Doppler. For lengths greater than 90 ms, the pulsing window was preset during diastole (during 60%–80%); otherwise, the optimal pulsing intervals were moved from diastole to systole (during 30%–50%). Results The mean heart rates of the traditional ECG and the Doppler-guided group during CT scanning were 75.0±7.7 bpm (range, 66–96 bpm) and 76.5±5.4 bpm (range: 66–105 bpm), respectively. The results indicated that whereas the image quality showed no significant difference between the traditional and Doppler groups (P = 0.42), the radiation dose of the Doppler group was significantly lower than that of the traditional group (5.2±3.4mSv vs. 9.3±4.5mSv, P<0.001). The sensitivities of CTA applying traditional and Doppler-guided prospective ECG gating to diagnose stenosis on a segment level were 95.5% and 94.3%, respectively; specificities 98.0% and 97.1%, respectively; positive predictive values 90.7% and 88.2%, respectively; negative predictive values 99.0% and 98.7%, respectively. There was no statistical difference in concordance between the traditional and Doppler groups (P = 0.22). Conclusion Doppler-guided prospective ECG gating represents an improved method in patients with a high heart rate to reduce effective radiation doses, while maintaining high diagnostic accuracy. PMID:23696793

  2. Changes in Heart Rate Associated with Exenatide Once Weekly: Pooled Analysis of Clinical Data in Patients with Type 2 Diabetes.

    PubMed

    Marso, Steven P; Hardy, Elise; Han, Jenny; Wang, Hui; Chilton, Robert J

    2018-04-01

    Glucagon-like peptide-1 receptor agonists (GLP-1RAs) improve glycemia in patients with type 2 diabetes, but heart rate increases have been observed. A pooled post hoc analysis of 11 randomized clinical trials (N = 4595) of 10-30 weeks' duration from the exenatide once-weekly (QW) development program evaluated heart rate with exenatide QW (intervention group) and exenatide twice daily (BID), liraglutide, and non-GLP-1RAs (insulin, metformin, pioglitazone, and sitagliptin) (comparison groups). The time course and size of heart rate changes from baseline and the relationship of heart rate change with baseline heart rate were studied. A multivariate analysis (9 studies; N = 3903) examined associations between patient characteristics or treatments and heart rate increases. Mean baseline heart rate ± standard deviation was 75.0 ± 8.5 beats per minute (bpm) with exenatide QW (n = 2096), 75.8 ± 8.7 bpm with exenatide BID (n = 606), 75.2 ± 8.9 bpm with liraglutide (n = 450), and 74.5 ± 8.6 bpm with non-GLP-1RAs (n = 1443). Least-squares mean ± standard error changes from baseline to final heart rate were + 2.7 ± 0.2, + 1.0 ± 0.3, and + 3.0 ± 0.4 bpm with exenatide QW, exenatide BID, and liraglutide, respectively, and - 0.8 ± 0.2 bpm with non-GLP-1RAs. The size and direction of heart rate changes in individual patients varied within each treatment group at all time points. At posttreatment follow-up, heart rate reverted to the baseline level after GLP-1RA discontinuation. Heart rate changes correlated negatively with baseline heart rate for all therapies (r = - 0.3 to - 0.4). Baseline heart rate was the strongest predictor of increased heart rate. Small increases in heart rate were associated with exenatide QW, exenatide BID, and liraglutide treatments but reverted to baseline after discontinuation. Increases were more likely in patients with a low baseline heart rate. The clinical relevance of these heart rate increases is unknown but will be clarified by several ongoing and recently completed cardiovascular outcome studies.

  3. Supporting interoperability of collaborative networks through engineering of a service-based Mediation Information System (MISE 2.0)

    NASA Astrophysics Data System (ADS)

    Benaben, Frederick; Mu, Wenxin; Boissel-Dallier, Nicolas; Barthe-Delanoe, Anne-Marie; Zribi, Sarah; Pingaud, Herve

    2015-08-01

    The Mediation Information System Engineering project is currently finishing its second iteration (MISE 2.0). The main objective of this scientific project is to provide any emerging collaborative situation with methods and tools to deploy a Mediation Information System (MIS). MISE 2.0 aims at defining and designing a service-based platform, dedicated to initiating and supporting the interoperability of collaborative situations among potential partners. This MISE 2.0 platform implements a model-driven engineering approach to the design of a service-oriented MIS dedicated to supporting the collaborative situation. This approach is structured in three layers, each providing their own key innovative points: (i) the gathering of individual and collaborative knowledge to provide appropriate collaborative business behaviour (key point: knowledge management, including semantics, exploitation and capitalisation), (ii) deployment of a mediation information system able to computerise the previously deduced collaborative processes (key point: the automatic generation of collaborative workflows, including connection with existing devices or services) (iii) the management of the agility of the obtained collaborative network of organisations (key point: supervision of collaborative situations and relevant exploitation of the gathered data). MISE covers business issues (through BPM), technical issues (through an SOA) and agility issues of collaborative situations (through EDA).

  4. An Autonomous Wireless Sensor Node With Asynchronous ECG Monitoring in 0.18 μ m CMOS.

    PubMed

    Mansano, Andre L; Li, Yongjia; Bagga, Sumit; Serdijn, Wouter A

    2016-06-01

    The design of a 13.56 MHz/402 MHz autonomous wireless sensor node with asynchronous ECG monitoring for near field communication is presented. The sensor node consists of an RF energy harvester (RFEH), a power management unit, an ECG readout, a data encoder and an RF backscattering transmitter. The energy harvester supplies the system with 1.25 V and offers a power conversion efficiency of 19% from a -13 dBm RF source at 13.56 MHz. The power management unit regulates the output voltage of the RFEH to supply the ECG readout with VECG = 0.95 V and the data encoder with VDE = 0.65 V . The ECG readout comprises an analog front-end (low noise amplifier and programmable voltage to current converter) and an asynchronous level crossing ADC with 8 bits resolution. The ADC output is encoded by a pulse generator that drives a backscattering transmitter at 402 MHz. The total power consumption of the sensor node circuitry is 9.7 μ W for a data rate of 90 kb/s and a heart rate of 70 bpm. The chip has been designed in a 0.18 μm CMOS process and shows superior RF input power sensitivity and lower power consumption when compared to previous works.

  5. NSLS-II BPM System Protection from Rogue Mode Coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blednykh, A.; Bach, B.; Borrelli, A.

    2011-03-28

    Rogue mode RF shielding has been successfully designed and implemented into the production multipole vacuum chambers. In order to avoid systematic errors in the NSLS-II BPM system we introduced frequency shift of HOM's by using RF metal shielding located in the antechamber slot of each multipole vacuum chamber. To satisfy the pumping requirement the face of the shielding has been perforated with roughly 50 percent transparency. It stays clear of synchrotron radiation in each chamber.

  6. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor.

    PubMed

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L; Minassian, Arpi

    2016-06-30

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Thermoregulatory responses of Holstein cows exposed to experimentally induced heat stress.

    PubMed

    de Andrade Ferrazza, Rodrigo; Mogollón Garcia, Henry David; Vallejo Aristizábal, Viviana Helena; de Souza Nogueira, Camilla; Veríssimo, Cecília José; Sartori, José Roberto; Sartori, Roberto; Pinheiro Ferreira, João Carlos

    2017-05-01

    Heat stress (HS) adversely influences productivity and welfare of dairy cattle. We hypothesized that the thermoregulatory mechanisms vary depending on the exposure time to HS, with a cumulative effect on the adaptive responses and thermal strain of the cow. To identify the effect of HS on adaptive thermoregulatory mechanisms and predictors of caloric balance, Holstein cows were housed in climate chambers and randomly distributed into thermoneutral (TN; n=12) or HS (n=12) treatments for 16 days. Vaginal temperature (VT), rectal temperature (Tre), respiratory rate (RR), heart rate (HR), and dry matter intake (DMI) were measured. The temperature and humidity under TN were 25.9±0.2°C and 73.0±0.8%, respectively, and under HS were 36.3±0.3°C and 60.9±0.9%, respectively. The RR of the HS cows increased immediately after exposure to heat and was higher (76.02±1.70bpm, p<0.001) than in the TN (39.70±0.71bpm). An increase in Tre (39.87±0.07°C in the HS vs. 38.56±0.03°C in the TN, p<0.001) and in VT (39.82±0.10°C in the HS vs. 38.26±0.03°C in the TN, p<0.001) followed the increase in RR. A decrease (p<0.05) in HR occurred in the HS (62.13±0.99bpm) compared with the TN (66.23±0.79bpm); however, the magnitude of the differences was not the same over time. The DMI was lower in HS cows from the third day (8.27±0.33kgd -1 in the HS vs. 14.03±0.29kgd -1 in the TN, p<0.001), and the reduction of DMI was strongly affected (r=-0.65) by changes in the temperature humidity index. The effect of environmental variables from the previous day on physiological parameters and DMI was more important than the immediate effect, and ambient temperature represented the most determinant factor for heat exchange. The difference in the responses to acute and chronic exposure to HS suggests an adaptive response. Thus, intense thermal stress strongly influence thermoregulatory mechanisms and the acclimation process depend critically on heat exposure time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Volumetric Single-Beat Coronary Computed Tomography Angiography: Relationship of Image Quality, Heart Rate, and Body Mass Index. Initial Patient Experience With a New Computed Tomography Scanner.

    PubMed

    Latif, Muhammad Aamir; Sanchez, Frank W; Sayegh, Karl; Veledar, Emir; Aziz, Muhammad; Malik, Rehan; Haider, Imran; Agatston, Arthur S; Batlle, Juan C; Janowitz, Warren; Peña, Constantino; Ziffer, Jack A; Nasir, Khurram; Cury, Ricardo C

    2016-01-01

    Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and greater than 70 bpm and also analyzed them in 2 BMI groupings: BMI less than or equal to 30 kg/m and BMI greater than 30 kg/m. Mean SNR was 8.7 (SD, 3.1) (n = 349) for group with HR 70 bpm or less and 7.7 (SD, 2.4) (n = 78) for group with HR greater than 70 bpm (P = 0.008). Mean CNR was 6.9 (SD, 2.7) (n = 349) for group with HR 70 bpm or less and 5.9 (SD, 2.2) (n = 78) for group with HR 70 bpm or greater (P = 0.002). Mean SNR was 8.8 (SD, 3.2) (n = 249) for group with BMI 30 kg/m or less and 8.1 (SD, 2.6) (n = 176) for group with BMI greater than 30 kg/m (P = 0.008). Mean CNR was 7.0 (SD, 2.8) (n = 249) for group with BMI 30 kg/m or less and 6.4 (SD, 2.4) (n = 176) for group with BMI greater than 30 kg/m (P = 0.002). The results for mean Likert scale values were statistically different, reflecting difference in IQ between people with HR 70 bpm or less and greater than 70 bpm, BMI 30 kg/m or less, and BMI greater than 30 kg/m.

  9. [Status of β-blocker use and heart rate control in Chinese patients with stable coronary artery disease].

    PubMed

    Sun, Yihong; Yu, Jinming; Hu, Dayi

    2016-01-01

    To observe the current status of β-blocker (BB) use and heart rate control in Chinese patients with stable coronary artery disease (SCAD) based on subgroup data of the prospective observational longitudinal registry of patients with stable coronary artery disease (CLARIFY). The CLARIFY study is an international prospective observational registry of outpatients with SCAD. From November 2009 to July 2010, patients with SCAD were enrolled, and demographic information, clinical indicators, medication and blood flow reconstruction were collected. Patients were divided in three mutually exclusive categories by baseline pulse palpation heart rate(HR)≤60 beats per minute (bpm)(n=397), 61-69 bpm(n=782), and ≥70 bpm(n=1 443). The patients were also divided into taking BB or not taking BB groups. The aim of present study is to describe and analyze the current status and factors related to the HR control and BB use in the Chinese subgroup of CLARIFY. A total of 2 622 patients were enrolled from 56 centers across China. The mean age was (63.6±10.3) years old with 75.6% (1 983) male patients, 55.0% (1 443) patients had HR≥70 bpm. Mean HR measure by electrocardiogram(ECG) was (69.4±10.2)bpm, 50.9% (1 334 cases) patients had myocardial infarction(MI) history. A total of 21.9%(575 cases) patients had anginal symptoms; coronary angiography was performed in 88.8%(2 327 cases) of the patients. 76.2%(1 997 cases) patients were treated with BB (any molecule and any dose), 2.7% (70 cases) with digoxin or derivatives, 3.9% (103 cases) with verapamil or diltiazem, and 1.8% (47 cases) with amiodarone or dronedarone and 0.1%(2 cases) received ivabradine. BB use was similar among 3 HR groups(P>0.05). The independent risk factors associated with HR≥70 bpm were diabetes(OR=1.31), current smoker(OR=1.57), chronic heart failure(CHF) with NYHA Ⅲ (OR=2.13) and increased diastolic blood pressure (OR=1.30). Conversely, high physical activity (OR=0.61), former smoker (OR=0.76) and history of percutaneous coronary intervention(PCI, OR=0.80) were associated with lower risk of HR≥70 bpm (all P<0.05). The independent risk factors associated with non-BB use were older age (OR=1.11, 95%CI 1.01-1.47, P=0.005), lower diastolic blood pressure (OR=1.47, 95%CI 1.32-1.68, P=0.012), no history of MI (OR=1.86, 95%CI 1.43-2.44, P<0.001) or PCI (OR=1.94, 95%CI 1.55-3.73, P<0.001), asthma/chronic obstructive pulmonary disease (OR=1.32, 95%CI 1.15-1.99, P<0.001). A total of 76.2% Chinese SCAD patients received BB medication but more than half of them did not reach the optimal HR. Clinical characteristics including diabetes, current smoker, CHF, increased diastolic blood pressure and no PCI were associated with poorly controlled HR(≥70 bpm). More efforts including adjusting the type and dose of heart rate lowering drugs are needed to achieve optimal HR control in Chinese SCAD patients. Clinical Trail Registry International Standard Randomized Controlled Trial, ISRCTN43070564.

  10. Effect of Metoprolol Succinate in Patients with Stable Angina and Elevated Heart Rate Receiving Low-Dose β-Blocker Therapy.

    PubMed

    Jiang, Jie; Cong, Hongliang; Zhang, Yan; Li, Zhanquan; Tao, Guizhou; Li, Xiaodong; Qing, Liang; Tan, Ning; Zhao, Zhichen; Dong, Yugang; Ji, Zheng; Chen, Yundai; Ge, Junbo; He, Ben; Sun, Yingxian; Cao, Kejiang; Huo, Yong

    2017-01-01

    Aims: β-blockers are underused in Chinese patients with coronary heart disease. The prescribed dose is often low. The aim of this study was to investigate the effect of metoprolol succinate doses of 95 mg and 190 mg on heart rate (HR) control, as well as drug tolerance, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Methods: This was a multicenter, randomized, open-label, parallel-group trial in 15 clinical sites. Patients with stable angina, taking low-dose β-blockers (equivalent to metoprolol succinate 23.75-47.5 mg/day), and having a resting HR of ≥ 65 bpm were enrolled and randomized to either the metoprolol 95-mg group or the 190-mg group. The change in 24-h average HR from baseline recorded by Holter monitoring and the percentages of patients with resting HR controlled to ≤ 60 bpm were compared between the two groups. Results: Two hundred thirty-one patients entered the intent-to-treat population for the main analysis. The change in 24-h average HR from baseline was -0.62 ± 0.66 bpm in the 95 mg group and -2.99 ± 0.62 bpm in the 190 mg group (p = 0.0077) after 8 weeks of treatment. The percentages of patients with resting HR controlled to ≤ 60 bpm were 24.1% (95% CI: 16.35%, 31.93%) and 40.0% (95% CI: 31.05%, 48.95%), respectively (p = 0.0019). Only 4 and 2 of the patients, respectively, discontinued the study drugs because of hypotension or bradycardia. Conclusions: The metoprolol succinate dose of 190 mg is superior to the 95 mg dose in terms of HR control, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Both doses were well tolerated.

  11. The cost effectiveness of ivabradine in the treatment of chronic heart failure from the U.K. National Health Service perspective.

    PubMed

    Griffiths, A; Paracha, N; Davies, A; Branscombe, N; Cowie, M R; Sculpher, M

    2014-07-01

    Ivabradine, a specific heart rate lowering therapy, has been shown in a randomised placebo-controlled study, Systolic HF Treatment with the If Inhibitor Ivabradine Trial (SHIfT), to significantly reduce the composite end point of cardiovascular death and hospitalisation for worsening heart failure (HF) in patients with systolic HF who are in sinus rhythm and with a heart rate ≥70 bpm, when added to optimised medical therapy (HR: 0.82, 95% CI 0.75 to 0.90, p<0.0001). We assessed the cost effectiveness of ivabradine, from a UK National Health Service perspective, based on the results of SHIfT. A Markov model estimated the cost effectiveness of ivabradine compared with standard care for two cohorts of patients with HF (heart rate ≥75 bpm in line with the EU labelled indication; and heart rate ≥70 bpm in line with the SHIfT study population). Modelled outcomes included death, hospitalisation, quality of life and New York Heart Association class. Total costs and quality adjusted life years (QALYs) for ivabradine and standard care were estimated over a lifetime horizon. The incremental cost per additional QALY for ivabradine plus standard care versus standard care has been estimated as £8498 for heart rate ≥75 bpm and £13 764 for heart rate ≥70 bpm. Ivabradine is expected to have a 95% chance of being cost-effective in the EU licensed population using the current National Institute for Health and Care Excellence cost effectiveness threshold of £20 000 per QALY. These results were robust in sensitivity analyses. This economic evaluation suggests that the use of ivabradine is likely to be cost-effective in eligible patients with HF from a UK National Health Service perspective. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Sympathetic activation in exercise is not dependent on muscle acidosis. Direct evidence from studies in metabolic myopathies

    NASA Technical Reports Server (NTRS)

    Vissing, J.; Vissing, S. F.; MacLean, D. A.; Saltin, B.; Quistorff, B.; Haller, R. G.; Blomqvist, C. G. (Principal Investigator)

    1998-01-01

    Muscle acidosis has been implicated as a major determinant of reflex sympathetic activation during exercise. To test this hypothesis we studied sympathetic exercise responses in metabolic myopathies in which muscle acidosis is impaired or augmented during exercise. As an index of reflex sympathetic activation to muscle, microneurographic measurements of muscle sympathetic nerve activity (MSNA) were obtained from the peroneal nerve. MSNA was measured during static handgrip exercise at 30% of maximal voluntary contraction force to exhaustion in patients in whom exercise-induced muscle acidosis is absent (seven myophosphorylase deficient patients; MD [McArdle's disease], and one patient with muscle phosphofructokinase deficiency [PFKD]), augmented (one patient with mitochondrial myopathy [MM]), or normal (five healthy controls). Muscle pH was monitored by 31P-magnetic resonance spectroscopy during handgrip exercise in the five control subjects, four MD patients, and the MM and PFKD patients. With handgrip to exhaustion, the increase in MSNA over baseline (bursts per minute [bpm] and total activity [%]) was not impaired in patients with MD (17+/-2 bpm, 124+/-42%) or PFKD (65 bpm, 307%), and was not enhanced in the MM patient (24 bpm, 131%) compared with controls (17+/-4 bpm, 115+/-17%). Post-handgrip ischemia studied in one McArdle patient, caused sustained elevation of MSNA above basal suggesting a chemoreflex activation of MSNA. Handgrip exercise elicited an enhanced drop in muscle pH of 0.51 U in the MM patient compared with the decrease in controls of 0.13+/-0.02 U. In contrast, muscle pH increased with exercise in MD by 0.12+/-0.05 U and in PFKD by 0.01 U. In conclusion, patients with glycogenolytic, glycolytic, and oxidative phosphorylation defects show normal muscle sympathetic nerve responses to static exercise. These findings indicate that muscle acidosis is not a prerequisite for sympathetic activation in exercise.

  13. Brain-computer interfaces using capacitive measurement of visual or auditory steady-state responses

    NASA Astrophysics Data System (ADS)

    Baek, Hyun Jae; Kim, Hyun Seok; Heo, Jeong; Lim, Yong Gyu; Park, Kwang Suk

    2013-04-01

    Objective. Brain-computer interface (BCI) technologies have been intensely studied to provide alternative communication tools entirely independent of neuromuscular activities. Current BCI technologies use electroencephalogram (EEG) acquisition methods that require unpleasant gel injections, impractical preparations and clean-up procedures. The next generation of BCI technologies requires practical, user-friendly, nonintrusive EEG platforms in order to facilitate the application of laboratory work in real-world settings. Approach. A capacitive electrode that does not require an electrolytic gel or direct electrode-scalp contact is a potential alternative to the conventional wet electrode in future BCI systems. We have proposed a new capacitive EEG electrode that contains a conductive polymer-sensing surface, which enhances electrode performance. This paper presents results from five subjects who exhibited visual or auditory steady-state responses according to BCI using these new capacitive electrodes. The steady-state visual evoked potential (SSVEP) spelling system and the auditory steady-state response (ASSR) binary decision system were employed. Main results. Offline tests demonstrated BCI performance high enough to be used in a BCI system (accuracy: 95.2%, ITR: 19.91 bpm for SSVEP BCI (6 s), accuracy: 82.6%, ITR: 1.48 bpm for ASSR BCI (14 s)) with the analysis time being slightly longer than that when wet electrodes were employed with the same BCI system (accuracy: 91.2%, ITR: 25.79 bpm for SSVEP BCI (4 s), accuracy: 81.3%, ITR: 1.57 bpm for ASSR BCI (12 s)). Subjects performed online BCI under the SSVEP paradigm in copy spelling mode and under the ASSR paradigm in selective attention mode with a mean information transfer rate (ITR) of 17.78 ± 2.08 and 0.7 ± 0.24 bpm, respectively. Significance. The results of these experiments demonstrate the feasibility of using our capacitive EEG electrode in BCI systems. This capacitive electrode may become a flexible and non-intrusive tool fit for various applications in the next generation of BCI technologies.

  14. A protocol to study ex vivo mouse working heart at human-like heart rate.

    PubMed

    Feng, Han-Zhong; Jin, Jian-Ping

    2018-01-01

    Genetically modified mice are widely used as experimental models to study human heart function and diseases. However, the fast rate of normal mouse heart at 400-600bpm limits its capacity of assessing kinetic parameters that are important for the physiology and pathophysiology of human heart that beats at a much slower rate (75-180bpm). To extend the value of mouse models, we established a protocol to study ex vivo mouse working hearts at a human-like heart rate. In the presence of 300μM lidocaine to lower pacemaker and conductive activities and prevent arrhythmia, a stable rate of 120-130bpm at 37°C is achieved for ex vivo mouse working hearts. The negative effects of decreased heart rate on force-frequency dependence and lidocaine as a myocardial depressant on intracellular calcium can be compensated by using a higher but still physiological level of calcium (2.75mM) in the perfusion media. Multiple parameters were studied to compare the function at the human-like heart rate with that of ex vivo mouse working hearts at the standard rate of 480bpm. The results showed that the conditions for slower heart rate in the presence of 300μM lidocaine did not have depressing effect on left ventricular pressure development, systolic and diastolic velocities and stroke volume with maintained positive inotropic and lusitropic responses to β-adrenergic stimulation. Compared with that at 480bpm, the human-like heart rate increased ventricular filling and end diastolic volume with enhanced Frank-Starling responses. Coronary perfusion was increased from longer relaxation time and interval between beats whereas cardiac efficiency was significantly improved. Although the intrinsic differences between mouse and human heart remain, this methodology for ex vivo mouse hearts to work at human-like heart rate extends the value of using genetically modified mouse models to study cardiac function and human heart diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Improved Heart Rate Recovery After Marked Weight Loss Induced by Gastric Bypass Surgery: 2 Year Follow Up in the Utah Obesity Study

    PubMed Central

    Wasmund, Stephen L.; Yanowitz, Frank G.; Adams, Ted D.; Hunt, Steven C.; Hamdan, Mohamed H.; Litwin, Sheldon E.

    2010-01-01

    Background Obesity is associated with significantly increased cardiovascular mortality that has been attributed, in part, to sympathetic activation. Gastric bypass surgery (GBS) appears to increase long-term survival in the severely obese, but mechanisms responsible for this increase are still being sought. Heart rate (HR) recovery after exercise reflects the balance of cardiac autonomic input from the sympathetic and parasympathetic systems. Blunted HR recovery is a very powerful predictor of increased mortality while enhanced HR recovery portends a good prognosis. Objectives To evaluate the effect of marked weight loss achieved via GBS on HR recovery. Methods Severely obese patients underwent submaximal exercise testing (80% predicted maximum HR) at baseline and 2 years after GBS (n=153) or nonsurgical treatment (n=188). Results Patients in the GBS group lost an average of 100±37 lbs compared to 3±22 lbs in the nonsurgical group (p<0.001, GBS vs. nonsurgical). Resting HR decreased from 73 beats/minute (bpm) to 60 bpm in the GBS group and from 74 bpm to 68 bpm in nonsurgical patients (p<0.001). Heart rate recovery improved by 13 bpm in the GBS group and did not change in the nonsurgical group (p<0.001 GBS vs. nonsurgical). In multivariable analysis, the independent correlates of HR recovery at the 2-year time point were resting HR, treadmill time, age, body mass index and HOMA-IR. Conclusion Marked weight loss 2 years after GBS resulted in a significant decrease in resting HR and an enhancement in HR recovery after exercise. These changes are likely attributable to improvement in insulin sensitivity and cardiac autonomic balance. Whether and to what extent this contributes to a reduction in cardiovascular mortality with GBS remains to be determined. PMID:20970524

  16. Effect of Metoprolol Succinate in Patients with Stable Angina and Elevated Heart Rate Receiving Low-Dose β-Blocker Therapy

    PubMed Central

    Jiang, Jie; Cong, Hongliang; Zhang, Yan; Li, Zhanquan; Tao, Guizhou; Li, Xiaodong; Qing, Liang; Tan, Ning; Zhao, Zhichen; Dong, Yugang; Ji, Zheng; Chen, Yundai; Ge, Junbo; He, Ben; Sun, Yingxian; Cao, Kejiang; Huo, Yong

    2017-01-01

    Aims: β-blockers are underused in Chinese patients with coronary heart disease. The prescribed dose is often low. The aim of this study was to investigate the effect of metoprolol succinate doses of 95 mg and 190 mg on heart rate (HR) control, as well as drug tolerance, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Methods: This was a multicenter, randomized, open-label, parallel-group trial in 15 clinical sites. Patients with stable angina, taking low-dose β-blockers (equivalent to metoprolol succinate 23.75-47.5 mg/day), and having a resting HR of ≥ 65 bpm were enrolled and randomized to either the metoprolol 95-mg group or the 190-mg group. The change in 24-h average HR from baseline recorded by Holter monitoring and the percentages of patients with resting HR controlled to ≤ 60 bpm were compared between the two groups. Results: Two hundred thirty-one patients entered the intent-to-treat population for the main analysis. The change in 24-h average HR from baseline was -0.62 ± 0.66 bpm in the 95 mg group and -2.99 ± 0.62 bpm in the 190 mg group (p = 0.0077) after 8 weeks of treatment. The percentages of patients with resting HR controlled to ≤ 60 bpm were 24.1% (95% CI: 16.35%, 31.93%) and 40.0% (95% CI: 31.05%, 48.95%), respectively (p = 0.0019). Only 4 and 2 of the patients, respectively, discontinued the study drugs because of hypotension or bradycardia. Conclusions: The metoprolol succinate dose of 190 mg is superior to the 95 mg dose in terms of HR control, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Both doses were well tolerated. PMID:28539824

  17. Training symmetry of weight distribution after stroke: a randomized controlled pilot study comparing task-related reach, Bobath and feedback training approaches.

    PubMed

    Mudie, M H; Winzeler-Mercay, U; Radwan, S; Lee, L

    2002-09-01

    To determine (1) the most effective of three treatment approaches to retrain seated weight distribution long-term after stroke and (2) whether improvements could be generalized to weight distribution in standing. Inpatient rehabilitation unit. Forty asymmetrical acute stroke subjects were randomly allocated to one of four groups in this pilot study. Changes in weight distribution were compared between the 10 subjects of each of three treatment groups (task-specific reach, Bobath, or Balance Performance Monitor [BPM] feedback training) and a no specific treatment control group. One week of measurement only was followed by two weeks of daily training sessions with the treatment to which the subject was randomly allocated. Measurements were performed using the BPM daily before treatment sessions, two weeks after cessation of treatment and 12 weeks post study. Weight distribution was calculated in terms of mean balance (percentage of total body weight) or the mean of 300 balance points over a 30-s data run. In the short term, the Bobath approach was the most effective treatment for retraining sitting symmetry after stroke (p = 0.004). Training with the BPM and no training were also significant (p = 0.038 and p = 0.035 respectively) and task-specific reach training failed to reach significance (p = 0.26). At 12 weeks post study 83% of the BPM training group, 38% of the task-specific reach group, 29% of the Bobath group and 0% of the untrained group were found to be distributing their weight to both sides. Some generalization of symmetry training in sitting to standing was noted in the BPM training group which appeared to persist long term. Results should be treated with caution due to the small group sizes. However, these preliminary findings suggest that it might be possible to restore postural symmetry in sitting in the early stages of rehabilitation with therapy that focuses on creating an awareness of body position.

  18. Heart rate and ischemic stroke: the REasons for Geographic And Racial Differences in Stroke (REGARDS) study.

    PubMed

    O'Neal, Wesley T; Qureshi, Waqas T; Judd, Suzanne E; Meschia, James F; Howard, Virginia J; Howard, George; Soliman, Elsayed Z

    2015-12-01

    The association between resting heart rate and ischemic stroke remains unclear. To examine the association between resting heart rate and ischemic stroke. A total of 24 730 participants (mean age: 64 ± 9·3 years; 59% women; 41% blacks) from the REasons for Geographic And Racial Differences in Stroke (REGARDS) study who were free of stroke at the time of enrollment (2003-2007) were included in this analysis. Resting heart rate was determined from baseline electrocardiogram data. Heart rate was examined as a continuous variable per 10 bpm increase and also as a categorical variable using tertiles ( <61 bpm, 61 to 70 bpm, and >70 bpm). First-time ischemic stroke events were identified during follow-up and adjudicated by physician review. Over a median follow-up of 7·6 years, a total of 646 ischemic strokes occurred. In a Cox regression model adjusted for socio-demographics, cardiovascular risk factors, and potential confounders, each 10 bpm increase in heart rate was associated with a 10% increase in the risk of ischemic stroke (hazard ratio = 1·10, 95% confidence interval = 1·02, 1·18). In the categorical model, an increased risk of ischemic stroke was observed for heart rates in the middle (hazard ratio = 1·29, 95% confidence interval = 1·06, 1·57) and upper (hazard ratio = 1·37, 95% confidence interval = 1·12, 1·67) tertiles compared with the lower tertile. The results were consistent when the analysis was stratified by age, gender, race, exercise habits, hypertension, and coronary heart disease. In REGARDS, high resting heart rates were associated with an increased risk of ischemic stroke compared with low heart rates. Further research is needed to examine whether interventions aimed to reduce heart rate decrease stroke risk. © 2015 World Stroke Organization.

  19. A randomised, simulated study assessing auscultation of heart rate at birth.

    PubMed

    Voogdt, Kevin G J A; Morrison, Allison C; Wood, Fiona E; van Elburg, Ruurd M; Wyllie, Jonathan P

    2010-08-01

    Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated resuscitation scenarios. The VitalSim((c)) manikin (Laerdal Medical, Stavanger, Norway) was used in this randomised, single blind study. Four heart rate settings (0, 40, 80, 120 beats per minute (bpm)) were randomly assigned. Participants assessed them by auscultation in three different scenarios. The first scenario was to assess the actual heart rate at birth. In the second scenario, heart rate was assessed during ventilation and assigned to standard ranges (<60, 60-100, >100bpm). In the third scenario, heart rate was assessed after three cycles of compressions and ventilation and assigned to standard ranges. In total 61 midwives, nurses and doctors performed 183 assessments. Mean time to estimate heart rate for scenarios 1, 2 and 3 was: 17.0, 9.8 and 7.8s respectively. Heart rate assessments were inaccurate in 31% (scenario 1), 28% (scenarios 2) and 26% (scenario 3). There was a trend for assessors who were accurate to be quicker and this achieved significance in scenario 2 (p<0.02). Inaccurate assessment would have made a difference to management in 28% of all cases. Mean time to estimate heart rate for the scenarios varied between 7.8 and 17.0s. Twenty-eight percent of all heart rate assessments would have prompted incorrect management during resuscitation or stabilization. Of incorrect assessments, 73% were overestimations. Further research is required to develop a rapid and accurate method for determining heart rate during newborn resuscitation. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Optical communication system performance with tracking error induced signal fading.

    NASA Technical Reports Server (NTRS)

    Tycz, M.; Fitzmaurice, M. W.; Premo, D. A.

    1973-01-01

    System performance is determined for an optical communication system using noncoherent detection in the presence of tracking error induced signal fading assuming (1) binary on-off modulation (OOK) with both fixed and adaptive threshold receivers, and (2) binary polarization modulation (BPM). BPM is shown to maintain its inherent 2- to 3-dB advantage over OOK when adaptive thresholding is used, and to have a substantially greater advantage when the OOK system is restricted to a fixed decision threshold.

  1. Comparison of RF BPM Receivers for NSLS-II Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Singh, O.

    2009-05-04

    The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.

  2. Characterization of the Li beam probe with a beam profile monitor on JETa)

    NASA Astrophysics Data System (ADS)

    Nedzelskiy, I. S.; Korotkov, A.; Brix, M.; Morgan, P.; Vince, J.; Jet Efda Contributors

    2010-10-01

    The lithium beam probe (LBP) is widely used for measurements of the electron density in the edge plasma of magnetically confined fusion experiments. The quality of LBP data strongly depends on the stability and profile shape of the beam. The main beam parameters are as follows: beam energy, beam intensity, beam profile, beam divergence, and the neutralization efficiency. For improved monitoring of the beam parameters, a beam profile monitor (BPM) from the National Electrostatics Corporation (NEC) has been installed in the Li beam line at JET. In the NEC BPM, a single grounded wire formed into a 45° segment of a helix is rotated by a motor about the axis of the helix. During each full revolution, the wire sweeps twice across the beam to give X and Y profiles. In this paper, we will describe the properties of the JET Li beam as measured with the BPM and demonstrate that it facilitates rapid optimization of the gun performance.

  3. BPM Design and Impedance Considerations for a Rotatable Collimator for the LHC Collimation Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Jeffrey Claiborne; /SLAC; Keller, Lewis

    2010-08-26

    The Phase II upgrade to the LHC collimation system calls for complementing the 30 high robust Phase I graphite secondary collimators with 30 high Z Phase II collimators. This paper reports on BPM and impedance considerations and measurements of the integrated BPMs in the prototype rotatable collimator to be installed in the Super Proton Synchrotron (SPS) at CERN. The BPMs are necessary to align the jaws with the beam. Without careful design the beam impedance can result in unacceptable heating of the chamber wall or beam instabilities. The impedance measurements involve utilizing both a single displaced wire and two wiresmore » excited in opposite phase to disentangle the driving and detuning transverse impedances. Trapped mode resonances and longitudinal impedance are to also be measured and compared with simulations. These measurements, when completed, will demonstrate the device is fully operational and has the impedance characteristics and BPM performance acceptable for installation in the SPS.« less

  4. Arabidopsis thaliana BTB/ POZ-MATH proteins interact with members of the ERF/AP2 transcription factor family.

    PubMed

    Weber, Henriette; Hellmann, Hanjo

    2009-11-01

    In Arabidopsis thaliana, the BTB/POZ-MATH (BPM) proteins comprise a small family of six members. They have been described previously to use their broad complex, tram track, bric-a-brac/POX virus and zinc finger (BTB/POZ) domain to assemble with CUL3a and CUL3b and potentially to serve as substrate adaptors to cullin-based E3-ligases in plants. In this article, we show that BPMs can also assemble with members of the ethylene response factor/Apetala2 transcription factor family, and that this is mediated by their meprin and TRAF (tumor necrosis factor receptor-associated factor) homology (MATH) domain. In addition, we provide a detailed description of BPM gene expression patterns in different tissues and on abiotic stress treatments, as well as their subcellular localization. This work connects, for the first time, BPM proteins with ethylene response factor/Apetala2 family members, which is likely to represent a novel regulatory mechanism of transcriptional control.

  5. Characterization of the International Linear Collider damping ring optics

    NASA Astrophysics Data System (ADS)

    Shanks, J.; Rubin, D. L.; Sagan, D.

    2014-10-01

    A method is presented for characterizing the emittance dilution and dynamic aperture for an arbitrary closed lattice that includes guide field magnet errors, multipole errors and misalignments. This method, developed and tested at the Cornell Electron Storage Ring Test Accelerator (CesrTA), has been applied to the damping ring lattice for the International Linear Collider (ILC). The effectiveness of beam based emittance tuning is limited by beam position monitor (BPM) measurement errors, number of corrector magnets and their placement, and correction algorithm. The specifications for damping ring magnet alignment, multipole errors, number of BPMs, and precision in BPM measurements are shown to be consistent with the required emittances and dynamic aperture. The methodology is then used to determine the minimum number of position monitors that is required to achieve the emittance targets, and how that minimum depends on the location of the BPMs. Similarly, the maximum tolerable multipole errors are evaluated. Finally, the robustness of each BPM configuration with respect to random failures is explored.

  6. Tilting-induced decrease in systolic blood pressure in bedridden hypertensive elderly inpatients: effects of azelnidipine.

    PubMed

    Morimoto, Shigeto; Takahashi, Takashi; Okaishi, Kohya; Nakahashi, Takeshi; Nomura, Kohji; Kanda, Tsugiyasu; Okuro, Masashi; Murai, Hiroshi; Nishino, Tomoichi; Matsumoto, Masayuki

    2006-12-01

    The object of this study was to examine blood pressure (BP) variability due to postural change in elderly hypertensive patients. The subjects studied were 154 elderly inpatients in a hospital for the elderly (48 male and 106 female; median age: 82 years), consisting of age- and sex-matched bedridden (n=39) and non-bedridden (n=39) normotensive controls and bedridden (n=38) and non-bedridden (n=38) hypertensive patients. BP and pulse rate (PR) were measured in the supine position, then again after a 2-min, 45 deg head-up tilt with the legs horizontal. The decrease in systolic BP (SBP) on tilting in the bedridden hypertensive group (median: -10 mmHg; range: -32 to 9 mmHg) was significantly (p<0.008) greater than those in the other three groups. Monotherapy with azeinidipine, a long-acting calcium channel blocker, for 3 months not only significantly reduced the basal BP and PR of hypertensive patients in the two groups, but also significantly (p<0.05) attenuated the tilt-induced decrease in the SBP to -3 mmHg (-19 to 25 mmHg) and enhanced the change in PR from -1 bpm (-10 to 7 bpm) to 1 bpm (-4 to 23 bpm) in the bedridden hypertensive group. Our findings indicate that tilt-induced decrease in SBP is a rather common phenomenon in bedridden elderly hypertensive patients, and that treatment with azelnidipine attenuates tilt-induced decrease in SBP, probably through an improvement of baroreceptor sensitivity.

  7. New approach for point pollution source identification in rivers based on the backward probability method.

    PubMed

    Wang, Jiabiao; Zhao, Jianshi; Lei, Xiaohui; Wang, Hao

    2018-06-13

    Pollution risk from the discharge of industrial waste or accidental spills during transportation poses a considerable threat to the security of rivers. The ability to quickly identify the pollution source is extremely important to enable emergency disposal of pollutants. This study proposes a new approach for point source identification of sudden water pollution in rivers, which aims to determine where (source location), when (release time) and how much pollutant (released mass) was introduced into the river. Based on the backward probability method (BPM) and the linear regression model (LR), the proposed LR-BPM converts the ill-posed problem of source identification into an optimization model, which is solved using a Differential Evolution Algorithm (DEA). The decoupled parameters of released mass are not dependent on prior information, which improves the identification efficiency. A hypothetical case study with a different number of pollution sources was conducted to test the proposed approach, and the largest relative errors for identified location, release time, and released mass in all tests were not greater than 10%. Uncertainty in the LR-BPM is mainly due to a problem with model equifinality, but averaging the results of repeated tests greatly reduces errors. Furthermore, increasing the gauging sections further improves identification results. A real-world case study examines the applicability of the LR-BPM in practice, where it is demonstrated to be more accurate and time-saving than two existing approaches, Bayesian-MCMC and basic DEA. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Directed self-assembly of high-chi block copolymer for nano fabrication of bit patterned media via solvent annealing

    NASA Astrophysics Data System (ADS)

    Xiong, Shisheng; Chapuis, Yves-Andre; Wan, Lei; Gao, He; Li, Xiao; Ruiz, Ricardo; Nealey, Paul F.

    2016-10-01

    We report the formation of nanoimprint master templates that can be used for the fabrication of bit patterned media (BPM). The template was formed by directed self-assembly, with solvent annealing, of a symmetric ABA triblock copolymer to form perpendicularly oriented lamellae on chemical patterns. We used a high-χ block copolymer, poly(2-vinyl pyridine)-block-polystyrene-block-poly(2-vinyl pyridine) to achieve smaller feature sizes than are possible with polystyrene-block-poly(methyl methacrylate). The work shows that triblock copolymers can provide a large processing window in terms of pitch commensurability. Using block-selective infiltration (atomic layer deposition with sequential long soaking/purge cycles), an alumina composite with high etch resistance was specifically incorporated into the polar and hydrophilic P2VP domains. Subsequently, the surface pattern was successfully transferred into underlying Si substrates by etching with a fluorine-containing plasma to create a nanoimprint master. The line/space pattern of the nanoimprint master met the BPM fabrication requirement of defectivity <10-3. For demonstration purposes, the nanoimprint master was used to imprint a replica pattern of photoresist on a quartz wafer.

  9. Oxygen enrichment and its application to life support systems for workers in high-altitude areas

    PubMed Central

    Li, Yongling; Liu, Yingshu

    2014-01-01

    Background: Workers coming from lowland regions are at risk of developing acute mountain sickness (AMS) when working in low oxygen high-altitude areas. Objectives: The aim of this study was to improve the conditions that lead to hypoxia and ensure the safety of the high-altitude workers. We analyzed the influence of low atmospheric pressure on the oxygen enrichment process in high-altitude areas using an engineering method called low-pressure swing adsorption (LPSA). Methods: Fourteen male subjects were screened and divided into three groups by type of oxygen supply system used: (1) oxygen cylinder group; (2) LPSA oxygen dispersal group; and (3) control group. These tests included arterial oxygen saturation (SaO2), pulse rate (PR), breaths per minute (BPM), and blood pressure (BP). Results: The results showed that after supplying oxygen using the LPSA method at the tunnel face, the SaO2 of workers increased; the incidence of acute mountain sickness, PR, and BPM significantly decreased. Conclusions: The LPSA life support system was found to be a simple, convenient, efficient, reliable, and applicable approach to ensure proper working conditions at construction sites in high-altitude areas. PMID:25000108

  10. Manually operatable on-chip bistable pneumatic microstructures for microfluidic manipulations.

    PubMed

    Chen, Arnold; Pan, Tingrui

    2014-09-07

    Bistable microvalves are of particular interest because of their distinct nature of requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries since microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integrability and a small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPMs) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly composed of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), of which users have direct control through finger pressing to switch either to the bistable vacuum state (VS) or the atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that processes blood samples to identify the distinct blood types (A/B/O) on-chip.

  11. Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking

    PubMed Central

    Jo, Edward; Lewis, Kiana; Directo, Dean; Kim, Michael J.; Dolezal, Brett A.

    2016-01-01

    The purpose of this study was to examine the validity of HR measurements by two commercial-use activity trackers in comparison to ECG. Twenty-four healthy participants underwent the same 77-minute protocol during a single visit. Each participant completed an initial rest period of 15 minutes followed by 5 minute periods of each of the following activities: 60W and 120W cycling, walking, jogging, running, resisted arm raises, resisted lunges, and isometric plank. In between each exercise task was a 5-minute rest period. Each subject wore a Basis Peak (BPk) on one wrist and a Fitbit Charge HR (FB) on the opposite wrist. Criterion measurement of HR was administered by 12-lead ECG. Time synced data from each device and ECG were concurrently and electronically acquired throughout the entire 77-minute protocol. When examining data in aggregate, there was a strong correlation between BPk and ECG for HR (r = 0.92, p < 0.001) with a mean bias of -2.5 bpm (95% LoA 19.3, -24.4). The FB demonstrated a moderately strong correlation with ECG for HR (r = 0.83, p < 0.001) with an average mean bias of -8.8 bpm (95% LoA 24.2, -41.8). During physical efforts eliciting ECG HR > 116 bpm, the BPk demonstrated an r = 0.77 and mean bias = -4.9 bpm (95% LoA 21.3, -31.0) while the FB demonstrated an r = 0.58 and mean bias = -12.7 bpm (95% LoA 28.6, -54.0). The BPk satisfied validity criteria for HR monitors, however showed a marginal decline in accuracy with increasing physical effort (ECG HR > 116 bpm). The FB failed to satisfy validity criteria and demonstrated a substantial decrease in accuracy during higher exercise intensities. Key points Modern day wearable multi-sensor activity trackers incorporate reflective photoplethymography (PPG) for heart rate detection and monitoring at the dorsal wrist. This study examined the validity of two PPG-based activity trackers, the Basis Peak and Fitbit Charge HR. The Basis Peak performed with accuracy compared with ECG and results substantiate validation of heart rate measurements. There was a slight decrease in performance during higher levels of physical exertion. The Fitbit Charge HR performed with poor accuracy compared with ECG especially during higher physical exertion and specific exercise tasks. The Fitbit Charge HR was not validated for heart rate monitoring, although better accuracy was observed during resting or recovery conditions. PMID:27803634

  12. Exposure to air pollution near a steel plant and effects on cardiovascular physiology: a randomized crossover study.

    PubMed

    Liu, Ling; Kauri, Lisa Marie; Mahmud, Mamun; Weichenthal, Scott; Cakmak, Sabit; Shutt, Robin; You, Hongyu; Thomson, Errol; Vincent, Renaud; Kumarathasan, Premkumari; Broad, Gayle; Dales, Robert

    2014-03-01

    Iron and steel industry is an important source of air pollution emissions. Few studies have investigated cardiovascular effects of air pollutants emitted from steel plants. We examined the influence of outdoor air pollution in the vicinity of a steel plant on cardiovascular physiology in Sault Ste. Marie, Canada. Sixty-one healthy, non-smoking subjects (females/males=33/28, median age 22 years) spent 5 consecutive 8-hour days outdoors in a residential area neighbouring a steel plant, or on a college campus approximately 5 kilometres away from the plant, and then crossed over to the other site with a 9-day washout. Mid day, subjects underwent daily 30-minute moderate intensity exercise. Blood pressure (BP) and pulse rate were determined daily and post exercise at both sites. Flow-mediated vasodilation (FMD) was determined at the site near the plant. Air pollution was monitored at both sites. Mixed-effects regressions were run for statistical associations, adjusting for weather variables. Concentrations of ultrafine particles, sulphur dioxide (SO2), nitrogen dioxide (NO2) and carbon monoxide (CO) were 50-100% higher at the site near the plant than at the college site, with minor differences in temperature, humidity, and concentrations of particulate matter ≤2.5 μm in size (PM2.5) and ozone (O3). Resting pulse rate [mean (95% confidence interval)] was moderately higher near the steel plant [+1.53 bpm (0.31, 2.78)] than at the college site, male subjects having the highest pulse rate elevation [+2.77 bpm (0.78, 4.76)]. Resting systolic and diastolic BP and pulse pressure, and post-exercise BP and pulse rate were not significantly different between two sites. Interquartile range concentrations of SO2 (2.9 ppb), NO2 (5.0 ppb) and CO (0.2 ppm) were associated with increased pulse rate [0.19 bpm (-0.00, 0.38), 0.86 bpm (0.03, 1.68), and 0.11 bpm (0.00, 0.22), respectively], ultrafine particles (10,256 count/cm(3)) associated with increased pulse pressure [0.85 mmHg (0.23, 1.48)], and NO2 and CO inversely associated with FMD [-0.14% (-0.31, 0.02), -0.02% (-0.03, -0.00), respectively]. SO2 during exercise was associated with increased pulse rate [0.26 bpm (0.01, 0.51)]. Air quality in residential areas near steel plants may influence cardiovascular physiology. Copyright © 2013 Elsevier GmbH. All rights reserved.

  13. New association of bone morphogenetic protein 4 concentrations with fat distribution in obesity and Exenatide intervention on it.

    PubMed

    Wang, Xingchun; Chen, Jiaqi; Li, Liang; Zhu, Cui Ling; Gao, Jingyang; Rampersad, Sharvan; Bu, Le; Qu, Shen

    2017-04-04

    Bone morphogenetic protein 4 (BMP-4) has been proven to regulate white adipogensis. We aimed to demonstrate the correlation of BMP-4 with fat distribution and Exenatide treatment on it. We enrolled 69 obese patients. Anthropometric and metabolic indexes were collected. Fat distribution was measured by dual-energy X-ray absorptiometry. BPM-4 levels were assessed using enzyme-link immunosorbent assay kit. 30 obese patients were treated with Exenatide twice a day. Change in body weight, metabolic-related indices and BPM-4 levels were evaluated after 18 weeks. 1) The mean(±SD) BMP-4 levels were 763.98 ± 324.11 pg/ml in the obese. BPM-4 levels were significantly positively correlated with estimated visceral adipose tissue mass in all subjects and also in females (r = 0.377, r = 0.625, respectively,all P < 0.05). BPM-4 levels were also significantly positively correlated with body mass index, hip circumference and total fat% in females (r = 0.375,r = 0.429,r = 0.493,respectively, all P < 0.05). BPM-4 levels were negatively correlated with total cholesterol(TC) in all subjects and males also (r = -0.373,r = -0.332,respectively, all P < 0.05). BPM-4 levels were also significantly positively correlated with free triiodothyronine in males (r = 0.441, P < 0.05). 3) Multivariate analyses showed that TC was risk factor of BMP-4 concentration in males and Est.VAT Area was risk factor of BMP-4 levels in females. 4) BMP-4 levels were significantly higher in the obesity with slightly increased thyroid stimulating hormone(TSH) than the obesity without slightly increased TSH (902.08 ± 354.74 pg/ml vs. 720.24 ± 306.41 pg/ml, P < 0.05). 5) Exenatide treatment leads to a significant decreased in BMP-4 from 860.05 ± 352.65 pg/ml to 649.44 + 277.49 pg/ml independent of weight loss(P < 0.05). BMP-4 levels were associated with the visceral adipose tissue and may play a certain role in fat distribution and subclinical hypothyroidism in obesity. Exenatide treatment reduced BMP-4 levels independent of weight loss. Clinicaltrials.gov Identifier: NCT02118376 , Registered 16 April.

  14. Beam propagation modeling of modified volume Fresnel zone plates fabricated by femtosecond laser direct writing.

    PubMed

    Srisungsitthisunti, Pornsak; Ersoy, Okan K; Xu, Xianfan

    2009-01-01

    Light diffraction by volume Fresnel zone plates (VFZPs) is simulated by the Hankel transform beam propagation method (Hankel BPM). The method utilizes circularly symmetric geometry and small step propagation to calculate the diffracted wave fields by VFZP layers. It is shown that fast and accurate diffraction results can be obtained with the Hankel BPM. The results show an excellent agreement with the scalar diffraction theory and the experimental results. The numerical method allows more comprehensive studies of the VFZP parameters to achieve higher diffraction efficiency.

  15. I(f) current inhibitor ivabradine in patients with idiopathic dilated cardiomyopathy: Impact on the exercise tolerance and quality of life.

    PubMed

    Abdel-Salam, Zainab; Rayan, Mona; Saleh, Ayman; Abdel-Barr, Mohamed G; Hussain, Mohamed; Nammas, Wail

    2015-01-01

    Evidence supported a beneficial effect of ivabradine on clinical outcome of patients with systolic heart failure, and a sinus heart rate (HR) ≥ 70 bpm. We explored the effect of ivabradine, vs. placebo, added to evidence-based treatment on exercise tolerance and quality of life in patients with idiopathic dilated cardiomyopathy. We enrolled 43 consecutive patients with dilated cardiomyopathy of no apparent cause, a left ventricular ejection fraction (LVEF) < 40%, New York Heart Association class ≥ II, sinus HR ≥ 70 bpm, and background evidence-based anti-failure medications. Ischemic heart disease was ruled out. Patients were randomized (1:1) to receive ivabradine or placebo. Ivabradine was titrated up gradually till 7.5 mg twice daily, or a HR < 60 bpm, and continued for 3 months. Symptom-limited exercise tolerance test was performed, and quality of life was assessed by the Minnesota Living With Heart Failure Questionnaire at 0, and 3 months. Forty-three patients were randomized to ivabradine (n = 20), or placebo (n = 23). Mean age was 50.8 ± 14.5 years (53.5% males). Mean HR was 85 ± 12 bpm, and mean LVEF was 32 ± 6%. Mean dose of carvedilol was 31.2% of the target dose. Baseline HR, blood pressure, exercise tolerance, Minnesota questionnaire score, and left ventricular systolic function were comparable between the two groups (p > 0.05 for all). At 3 months, mean dose of ivabradine was 6.8 mg bid. Ivabradine-treated patients had a lower HR, and improved left ventricular dimensions and systolic function, versus placebo-treated ones (p < 0.05 for all). HR dropped by a mean of 14 bpm in the ivabradine group, corrected for placebo. Both exercise tolerance, and Minnesota questionnaire score were better in the ivabradine group (p < 0.05 both). Ivabradine was well-tolerated. In symptomatic patients with idiopathic dilated cardiomyopathy, the addition of ivabradine, vs. placebo, to evidence-based treatment, reduced HR, and improved functional capacity, at short-term follow-up.

  16. The method used to set the pass mark in an objective structured clinical examination defines the performance of candidates for certification as rheumatologists.

    PubMed

    Pascual-Ramos, Virginia; Guilaisne Bernard-Medina, Ana; Flores-Alvarado, Diana Elsa; Portela-Hernández, Margarita; Maldonado-Velázquez, María Del Rocío; Jara-Quezada, Luis Javier; Amezcua-Guerra, Luis Manuel; Rubio-Judith López-Zepeda, Nadina E; Álvarez-Hernandez, Everardo; Saavedra, Miguel Ángel; Arce-Salinas, César Alejandro

    The Mexican Accreditation Council for Rheumatology certifies trainees (TR) on an annual basis using both a multiple-choice question (MCQ) test and an objective structured clinical examination (OSCE). For 2013 and 2014, the OSCE pass mark (PM) was set by criterion referencing as ≥6 (CPM), whereas overall rating of borderline performance method (BPM) was added for 2015 and 2016 accreditations. We compared OSCE TR performance according to CPM and BPM, and examined whether correlations between MCQ and OSCE were affected by PM. Forty-three (2015) and 37 (2016) candidates underwent both tests. Altogether, OSCE were integrated by 15 validated stations; one evaluator per station scored TR performance according to a station-tailored check-list and a Likert scale (fail, borderline, above range) of overall performance. A composite OSCE score was derived for each candidate. Appropriate statistics were used. Mean (±standard derivation [SD]) MCQ test scores were 6.6±0.6 (2015) and 6.4±0.6 (2016) with 5 candidates receiving a failing score each year. Mean (±SD) OSCE scores were 7.4±0.6 (2015) and 7.3±0.6 (2016); no candidate received a failing CPM score in either 2015 or 2016 OSCE, although 21 (49%) and 19 (51%) TR, respectively, received a failing BPM score (calculated as 7.3 and 7.4, respectively). Stations for BPM ranged from 4.5 to 9.5; overall, candidates showed better performance in CPM. In all, MCQ correlated with composite OSCE, r=0.67 (2015) and r=0.53 (2016); P≤.001. Trainees with a passing BPM score in OSCE had higher MCQ scores than those with a failing score. Overall, OSCE-PM selection impacted candidates' performance but had a limited affect on correlation between clinical and practical examinations. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  17. Music recommendation system for biofied building considering multiple residents

    NASA Astrophysics Data System (ADS)

    Ito, Takahiro; Mita, Akira

    2012-04-01

    This research presents a music recommendation system based on multiple users' communication excitement and productivity. Evaluation is conducted on following two points. 1, Does songA recommended by the system improve the situation of dropped down communication excitement? 2, Does songB recommended by the system improve the situation of dropped down and productivity of collaborative work? The objective of this system is to recommend songs which shall improve the situation of dropped down communication excitement and productivity. Songs are characterized according to three aspects; familiarity, relaxing and BPM(Beat Per Minutes). Communication excitement is calculated from speech data obtained by an audio sensor. Productivity of collaborative brainstorming is manually calculated by the number of time-series key words during mind mapping. First experiment was music impression experiment to 118 students. Based on 1, average points of familiarity, relaxing and BPM 2, cronbach alpha factor, songA(high familiarity, high relaxing and high BPM song) and songB(high familiarity, high relaxing and low BPM) are selected. Exploratory experiment defined dropped down communication excitement and dropped down and productivity of collaborative work. Final experiment was conducted to 32 first meeting students divided into 8 groups. First 4 groups had mind mapping 1 while listening to songA, then had mind mapping 2 while listening songB. Following 4 groups had mind mapping 1 while listening to songB, then had mind mapping 2 while listening songA. Fianl experiment shows two results. Firstly, ratio of communication excitement between music listening section and whole brain storming is 1.27. Secondly, this system increases 69% of average productivity.

  18. Using complexity metrics with R-R intervals and BPM heart rate measures.

    PubMed

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics-fractal (DFA) and recurrence (RQA) analyses-reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, "oversampled" BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics.

  19. Using complexity metrics with R-R intervals and BPM heart rate measures

    PubMed Central

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics—fractal (DFA) and recurrence (RQA) analyses—reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, “oversampled” BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics. PMID:23964244

  20. Raised cerebrovascular resistance in idiopathic orthostatic intolerance: evidence for sympathetic vasoconstriction

    NASA Technical Reports Server (NTRS)

    Jordan, J.; Shannon, J. R.; Black, B. K.; Paranjape, S. Y.; Barwise, J.; Robertson, D.

    1998-01-01

    Patients with idiopathic orthostatic intolerance (IOI) exhibit symptoms suggestive of cerebral hypoperfusion and an excessive decrease in cerebral blood flow associated with standing despite sustained systemic blood pressure. In 9 patients (8 women and 1 man aged 22 to 48 years) with IOI, we tested the hypothesis that volume loading (2000 cc normal saline) and alpha-adrenoreceptor agonism improve systemic hemodynamics and cerebral perfusion and that the decrease in cerebral blood flow with head-up tilt (HUT) could be attenuated by alpha-adrenoreceptor blockade with phentolamine. At 5 minutes of HUT, volume loading (-20+/-3.2 bpm) and phenylephrine (-18+/-3.4 bpm) significantly reduced upright heart rate compared with placebo; the effect was diminished at the end of HUT. Phentolamine substantially increased upright heart rate at 5 minutes (20+/-3.7 bpm) and at the end of HUT (14+/-5 bpm). With placebo, mean cerebral blood flow velocity decreased by 33+/-6% at the end of HUT. This decrease in cerebral blood flow with HUT was attenuated by all 3 interventions. We conclude that in patients with IOI, HUT causes a substantial decrease in cerebrovascular blood flow velocity. The decrease in blood flow velocity with HUT can be attenuated with interventions that improve systemic hemodynamics and therefore decrease reflex sympathetic activation. Moreover, alpha-adrenoreceptor blockade also blunts the decrease in cerebral blood flow with HUT but at the price of deteriorated systemic hemodynamics. These observations may suggest that in patients with IOI, excessive sympathetic activity contributes to the paradoxical decrease in cerebral blood flow with upright posture.

  1. Effect of training mode on post-exercise heart rate recovery of trained cyclists.

    PubMed

    McDonald, Kelia G; Grote, Silvie; Shoepe, Todd C

    2014-06-28

    The sympathetic nervous system dominates the regulation of body functions during exercise. Therefore after exercise, the sympathetic nervous system withdraws and the parasympathetic nervous system helps the body return to a resting state. In the examination of this relationship, the purpose of this study was to compare recovery heart rates (HR) of anaerobically versus aerobically trained cyclists. With all values given as means ± SD, anaerobically trained track cyclists (n=10, age=25.9 ± 6.0 yrs, body mass=82.7 ± 7.1 kg, body fat=10.0 ± 6.3%) and aerobically trained road cyclists (n=15, age=39.9 ± 8.5 yrs, body mass=75.3 ± 9.9 kg, body fat=13.1 ± 4.5%) underwent a maximal oxygen uptake test. Heart rate recovery was examined on a relative basis using heart rate reserve as well as the absolute difference between maximum HR and each of two recovery HRs. The post-exercise change in HR at minute one for the track cyclists and road cyclists respectively were 22 ± 8 bpm and 25 ± 12 bpm. At minute two, the mean drop for track cyclists was significantly (p<0.05) greater than the road cyclists (52 ± 15 bpm and 64 ± 11 bpm). Training mode showed statistically significant effects on the speed of heart rate recovery in trained cyclists. Greater variability in recovery heart rate at minute two versus minute one suggests that the heart rate should be monitored longer than one minute of recovery for a better analysis of post-exercise autonomic shift.

  2. Hemodynamic responses of unfit healthy women at a training session with nintendo wii: a possible impact on the general well-being.

    PubMed

    Monteiro-Junior, Renato S; Figueiredo, Luiz F; Conceição, Isabel; Carvalho, Carolina; Lattari, Eduardo; Mura, Gioia; Machado, Sérgio; da Silva, Elirez B

    2014-01-01

    The purpose of this study was assess the effect of a training session with Nintendo Wii® on the hemodynamic responses of healthy women not involved in regular physical exercise. Twenty-five healthy unfit women aged 28 ± 6 years played for 10 minutes the game Free Run (Wii Fit Plus). The resting heart rate (RHR), systolic and diastolic blood pressures (SBP and DBP), and double (rate-pressure) product (DP) were measured before and after activity. The HR during the activity (exercise heart rate, EHR) was measured every minute. A statistically significant difference was observed between the RHR (75 ± 9 bpm) and the mean EHR (176 ± 15 bpm) (P < 0.001). The EHR remained in the target zone for aerobic exercise until the fifth minute of activity, which coincided with the upper limit of the aerobic zone (80% heart rate reserve (HRR) + RHR) from the sixth to tenth minute. The initial (110 ± 8 mmHg) and final (145 ± 17 mmHg) SBP (P < 0.01) were significantly different, as were the initial (71 ± 8 mmHg) and final (79 ± 9 mmHg) DBP (P < 0.01). A statistically significant difference was observed between the pre- (8.233 ± 1.141 bpm-mmHg) and post-activity (25.590 ± 4.117 bpm-mmHg) DP (P < 0.01). Physical exercise while playing Free Run sufficed to trigger acute hemodynamic changes in healthy women who were not engaged in regular physical exercise.

  3. Hemodynamic Responses of Unfit Healthy Women at a Training Session with Nintendo Wii: A Possible Impact on the General Well-Being

    PubMed Central

    Monteiro-Junior, Renato S; Figueiredo, Luiz F; Conceição, Isabel; Carvalho, Carolina; Lattari, Eduardo; Mura, Gioia; Machado, Sérgio; da Silva, Elirez B

    2014-01-01

    Aims: The purpose of this study was assess the effect of a training session with Nintendo Wii® on the hemodynamic responses of healthy women not involved in regular physical exercise. Method: Twenty-five healthy unfit women aged 28 ± 6 years played for 10 minutes the game Free Run (Wii Fit Plus). The resting heart rate (RHR), systolic and diastolic blood pressures (SBP and DBP), and double (rate-pressure) product (DP) were measured before and after activity. The HR during the activity (exercise heart rate, EHR) was measured every minute. Results: A statistically significant difference was observed between the RHR (75 ± 9 bpm) and the mean EHR (176 ± 15 bpm) (P < 0.001). The EHR remained in the target zone for aerobic exercise until the fifth minute of activity, which coincided with the upper limit of the aerobic zone (80% heart rate reserve (HRR) + RHR) from the sixth to tenth minute. The initial (110 ± 8 mmHg) and final (145 ± 17 mmHg) SBP (P < 0.01) were significantly different, as were the initial (71 ± 8 mmHg) and final (79 ± 9 mmHg) DBP (P < 0.01). A statistically significant difference was observed between the pre- (8.233 ± 1.141 bpm-mmHg) and post-activity (25.590 ± 4.117 bpm-mmHg) DP (P < 0.01). Conclusion: Physical exercise while playing Free Run sufficed to trigger acute hemodynamic changes in healthy women who were not engaged in regular physical exercise. PMID:25614754

  4. The effect of practical cooling strategies on physiological response and cognitive function during simulated firefighting tasks

    PubMed Central

    Hemmatjo, Rasoul; Motamedzade, Majid; Aliabadi, Mohsen; Kalatpour, Omid; Farhadian, Maryam

    2017-01-01

    Background: Firefighters often perform multiple tasks during firefighting operations under unknown and unpredictable conditions in hot and hostile environments. Methods: In this interventional study each firefighters engaged in 4 conditions: namely (1) no cooling device; control (NC), (2) cooling gel (CG), (3) cool vest (CV), and (4) CG+CV. Cooling effects of the employed interventions were evaluated based on heart rate (HR), temporal temperature (TT), reaction time (RT), and the correct response (CR). Results: HR and TT values for use of CG+CV (147.47 bpm [SD 4.8]; 37.88°C [SD 0.20]) and CV bpm (147.53 [SD 4.67]; 37.90°C [SD 0.22]) were significantly lower than the CG (153.67 bpm [SD 4.82]; 38.10°C [SD 0.22]) and NC (154.4 bpm [SD 4.91]; 38.11°C [SD 0.23]) at the end of the activity. RT and CR for use of CG + CV (389.87 ms [SD 6.12]; 143.53 [SD 1.24]) and CV (389.53 ms [SD 6.24]; 143.47 [SD 1.18]) were significantly higher than the CG (385.73 [SD 7.25] ms; 143.07 [SD 0.88]) and NC (385.67 ms [SD 7.19]; 143.00 [SD 0.84]) at the end of the activity. Conclusion: It is concluded that CV was more effective than the CG in attenuating physiological responses and cognitive functions during firefighting operations. Furthermore, combining CV with CG provides no additional benefit. PMID:28326286

  5. Fault tolerance in protein interaction networks: stable bipartite subgraphs and redundant pathways.

    PubMed

    Brady, Arthur; Maxwell, Kyle; Daniels, Noah; Cowen, Lenore J

    2009-01-01

    As increasing amounts of high-throughput data for the yeast interactome become available, more system-wide properties are uncovered. One interesting question concerns the fault tolerance of protein interaction networks: whether there exist alternative pathways that can perform some required function if a gene essential to the main mechanism is defective, absent or suppressed. A signature pattern for redundant pathways is the BPM (between-pathway model) motif, introduced by Kelley and Ideker. Past methods proposed to search the yeast interactome for BPM motifs have had several important limitations. First, they have been driven heuristically by local greedy searches, which can lead to the inclusion of extra genes that may not belong in the motif; second, they have been validated solely by functional coherence of the putative pathways using GO enrichment, making it difficult to evaluate putative BPMs in the absence of already known biological annotation. We introduce stable bipartite subgraphs, and show they form a clean and efficient way of generating meaningful BPMs which naturally discard extra genes included by local greedy methods. We show by GO enrichment measures that our BPM set outperforms previous work, covering more known complexes and functional pathways. Perhaps most importantly, since our BPMs are initially generated by examining the genetic-interaction network only, the location of edges in the protein-protein physical interaction network can then be used to statistically validate each candidate BPM, even with sparse GO annotation (or none at all). We uncover some interesting biological examples of previously unknown putative redundant pathways in such areas as vesicle-mediated transport and DNA repair.

  6. Fault Tolerance in Protein Interaction Networks: Stable Bipartite Subgraphs and Redundant Pathways

    PubMed Central

    Brady, Arthur; Maxwell, Kyle; Daniels, Noah; Cowen, Lenore J.

    2009-01-01

    As increasing amounts of high-throughput data for the yeast interactome become available, more system-wide properties are uncovered. One interesting question concerns the fault tolerance of protein interaction networks: whether there exist alternative pathways that can perform some required function if a gene essential to the main mechanism is defective, absent or suppressed. A signature pattern for redundant pathways is the BPM (between-pathway model) motif, introduced by Kelley and Ideker. Past methods proposed to search the yeast interactome for BPM motifs have had several important limitations. First, they have been driven heuristically by local greedy searches, which can lead to the inclusion of extra genes that may not belong in the motif; second, they have been validated solely by functional coherence of the putative pathways using GO enrichment, making it difficult to evaluate putative BPMs in the absence of already known biological annotation. We introduce stable bipartite subgraphs, and show they form a clean and efficient way of generating meaningful BPMs which naturally discard extra genes included by local greedy methods. We show by GO enrichment measures that our BPM set outperforms previous work, covering more known complexes and functional pathways. Perhaps most importantly, since our BPMs are initially generated by examining the genetic-interaction network only, the location of edges in the protein-protein physical interaction network can then be used to statistically validate each candidate BPM, even with sparse GO annotation (or none at all). We uncover some interesting biological examples of previously unknown putative redundant pathways in such areas as vesicle-mediated transport and DNA repair. PMID:19399174

  7. Phosphorus removal from eutrophic water using modified biochar.

    PubMed

    Novais, Sarah Vieira; Zenero, Mariana Delgado Olivieira; Barreto, Matheus Sampaio Carneiro; Montes, Célia Regina; Cerri, Carlos Eduardo Pelegrino

    2018-08-15

    Increasing problems related to water eutrophication, commonly caused by the high concentration of phosphorus (P), are stimulating studies aimed at an environmentally safe solution. Moreover, some research has focused on the reuse of P due to concerns about the end of its natural reserves. Biochar appears to be a solution to both problems and may act as a recovery of eutrophic/residual water with the subsequent reuse of P in agriculture, the purpose of which is to test such an assertion. Samples of biochar from poultry manure (BPM) and sugarcane straw (BCS) had their maximum adsorption capacities of Al obtained by Langmuir isotherm. These values were used to conduct the so-called post-doping process, conferring P adsorption capacity to the pyrolysed materials. Langmuir and Freundlich isotherms were adjusted for the same biochar types (Al-doped) at increasing P concentrations, in order to obtain their maximum P adsorption capacities (MPAC) and their parameters. The desorption of the adsorbed P in its MPAC was tested by three extractors: H 2 SO 4 , NaHCO 3 , and H 2 O. Finally, these biochars were used in competitive adsorption assays of phosphate, sulfate, chloride and nitrate anions and applied in a synthetic eutrophic water. The high values of MPAC of the powder materials (701.65 and 758.96mgg -1 of P for BPM and BCS, respectively) are reduced by almost half for the fragment materials (356.04 and 468.84mgg -1 of P for BPM and BCS, respectively), these values being almost entirely extracted the extractors. Its application in eutrophic/residual water, in addition to presenting a good MPAC, these materials adsorbed, in equal proportions, phosphates and sulfates, as well as to a lesser extent, nitrates and chlorides. Thus, biochar from poultry manure and sugarcane straw, after post-doping with Al, have high MPAC, being excellent materials for the recovery of waters and subsequent reuse in agriculture. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. The impact of the perception of rhythmic music on self-paced oscillatory movements

    PubMed Central

    Peckel, Mathieu; Pozzo, Thierry; Bigand, Emmanuel

    2014-01-01

    Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping) while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20 s before a 2 s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced) while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with the task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e., motor/perceptual resonance). In general, our results give support to the notion that rhythmic music is processed in a motoric fashion. PMID:25278924

  9. Decreased baseline variability on fetal heart rate pattern in a fetus with heterotaxy syndrome.

    PubMed

    Yamada, Ryutaro; Takei, Kohta; Kaneshi, Yosuke; Morikawa, Mamoru; Cho, Kazutoshi; Minakami, Hisanori

    2015-12-01

    In a fetus with suspected heterotaxy syndrome, a decreased/absent baseline variability of fetal heart rate pattern developed at gestational week 36(+5) and continued for 5 days until birth at gestational week 37(+2), while repeat biophysical profile scorings with ultrasound were consistently unremarkable. This neonate weighing 2404 g with Apgar scores of 7 (1-min) and 8 (5-min) and umbilical arterial cord blood pH of 7.28 with base deficit of 3.9 mmol/L, showed a heart rate of 120 b.p.m. for 3 h after birth, but subsequently developed sinus bradycardia (84 b.p.m.) unresponsive to crying. Isoproterenol initiated 9 h after birth was effective in the increase of heart rate to 120 b.p.m. in this neonate. Brain magnetic resonance imaging at 16 days of age was unremarkable. The decreased/absent baseline variability of fetal heart rate pattern was speculated to have been caused by sinus node dysfunction, and not by reduced fetal oxygenation in this case. © 2015 Japan Society of Obstetrics and Gynecology.

  10. Results from a Test Fixture for button BPM Trapped Mode Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Bacha, B.; Blednykh, A.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1)more » Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.« less

  11. Improving the precision of linear optics measurements based on turn-by-turn beam position monitor data after a pulsed excitation in lepton storage rings

    NASA Astrophysics Data System (ADS)

    Malina, L.; Coello de Portugal, J.; Persson, T.; Skowroński, P. K.; Tomás, R.; Franchi, A.; Liuzzo, S.

    2017-08-01

    Beam optics control is of critical importance for machine performance and protection. Nowadays, turn-by-turn (TbT) beam position monitor (BPM) data are increasingly exploited as they allow for fast and simultaneous measurement of various optics quantities. Nevertheless, so far the best documented uncertainty of measured β -functions is of about 10‰ rms. In this paper we compare the β -functions of the ESRF storage ring measured from two different TbT techniques—the N-BPM and the Amplitude methods—with the ones inferred from a measurement of the orbit response matrix (ORM). We show how to improve the precision of TbT techniques by refining the Fourier transform of TbT data with properly chosen excitation amplitude. The precision of the N-BPM method is further improved by refining the phase advance measurement. This represents a step forward compared to standard TbT measurements. First experimental results showing the precision of β -functions pushed down to 4‰ both in TbT and ORM techniques are reported and commented.

  12. ETHERNET BASED EMBEDDED SYSTEM FOR FEL DIAGNOSTICS AND CONTROLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jianxun Yan; Daniel Sexton; Steven Moore

    2006-10-24

    An Ethernet based embedded system has been developed to upgrade the Beam Viewer and Beam Position Monitor (BPM) systems within the free-electron laser (FEL) project at Jefferson Lab. The embedded microcontroller was mounted on the front-end I/O cards with software packages such as Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS) running as an Input/Output Controller (IOC). By cross compiling with the EPICS, the RTEMS kernel, IOC device supports, and databases all of these can be downloaded into the microcontroller. The first version of the BPM electronics based on the embedded controller wasmore » built and is currently running in our FEL system. The new version of BPM that will use a Single Board IOC (SBIOC), which integrates with an Field Programming Gate Array (FPGA) and a ColdFire embedded microcontroller, is presently under development. The new system has the features of a low cost IOC, an open source real-time operating system, plug&play-like ease of installation and flexibility, and provides a much more localized solution.« less

  13. The use of 2D and 3D WA-BPM models to analyze total-internal-reflection-based integrated optical switches

    NASA Astrophysics Data System (ADS)

    Wang, Pengfei; Brambilla, Gilberto; Semenova, Yuliya; Wu, Qiang; Zheng, Jie; Farrell, Gerald

    2011-08-01

    The well known beam propagation method (BPM) has become one of the most useful, robust and effective numerical simulation tools for the investigation of guided-wave optics, for example integrated optical waveguides and fiber optic devices. In this paper we examine the use of the 2D and 3D wide angle-beam propagation method (WA-BPM) combined with the well known perfectly matched layer (PML) boundary conditions as a tool to analyze TIR based optical switches, in particular the relationship between light propagation and the geometrical parameters of a TIR based optical switch. To analyze the influence of the length and the width of the region in which the refractive index can be externally controlled, the 3D structure of a 2x2 TIR optical switch is firstly considered in 2D using the effective index method (EIM). Then the influence of the etching depth and the tilt angle of the reflection facet on the switch performance are investigated with a 3D model.

  14. A beam position monitor for the diagnostic line in MEBT2 of J-PARC linac

    NASA Astrophysics Data System (ADS)

    Miura, A.; Tamura, J.; Kawane, Y.

    2017-07-01

    In the linac of the Japan Proton Accelerator Research Complex (J-PARC), the neutral hydrogen (H0) beam from the negative hydrogen ion (H-) beam is one of key issues in mitigating beam losses. To diagnose H0 particles, we installed a set of beam-bump magnets to generate a chicane orbit of the H- beam. The beam position monitors (BPMs) in the beam line are used for orbit correction to maintain the beam displacement within 2.0 mm from the duct center. To measure the beam displacement under different drive currents of the beam-bump magnets, a new wide-range BPM was designed and manufactured to evaluate the horizontal beam position by using a correction function to compensate for non-linearity. We also employed the beam profile monitor (WSM: wire scanner monitor) to measure the H- beam profile, which helped us to compare the beam position measurements. In this paper, the design and the performance of the wide-range BPM are described. In addition, we present a comparison of the beam position measured by the BPM and the WSM.

  15. Independent component analysis applied to long bunch beams in the Los Alamos Proton Storage Ring

    NASA Astrophysics Data System (ADS)

    Kolski, Jeffrey S.; Macek, Robert J.; McCrady, Rodney C.; Pang, Xiaoying

    2012-11-01

    Independent component analysis (ICA) is a powerful blind source separation (BSS) method. Compared to the typical BSS method, principal component analysis, ICA is more robust to noise, coupling, and nonlinearity. The conventional ICA application to turn-by-turn position data from multiple beam position monitors (BPMs) yields information about cross-BPM correlations. With this scheme, multi-BPM ICA has been used to measure the transverse betatron phase and amplitude functions, dispersion function, linear coupling, sextupole strength, and nonlinear beam dynamics. We apply ICA in a new way to slices along the bunch revealing correlations of particle motion within the beam bunch. We digitize beam signals of the long bunch at the Los Alamos Proton Storage Ring with a single device (BPM or fast current monitor) for an entire injection-extraction cycle. ICA of the digitized beam signals results in source signals, which we identify to describe varying betatron motion along the bunch, locations of transverse resonances along the bunch, measurement noise, characteristic frequencies of the digitizing oscilloscopes, and longitudinal beam structure.

  16. Two-dimensional simulation of holographic data storage medium for multiplexed recording.

    PubMed

    Toishi, Mitsuru; Takeda, Takahiro; Tanaka, Kenji; Tanaka, Tomiji; Fukumoto, Atsushi; Watanabe, Kenjiro

    2008-02-18

    In this paper, we propose a new analysis model for photopolymer recording processes that calculate the two-dimensional refractive index distribution of multiplexed holograms. For the simulation of the photopolymer medium, time evolution of monomer diffusion and polymerization need to be calculated simultaneously. The distribution of the refractive index inside the medium is induced by these processes. By evaluating the refractive index pattern on each layer, the diffraction beams from the multiplexed hologram can be read out by beam propagation method (BPM). This is the first paper to determine the diffraction beam from a multiplexed hologram in a simulated photopolymer medium process. We analyze the time response of the multiplexed hologram recording processes in the photopolymer, and estimate the degradation of diffraction efficiency with multiplexed recording. This work can greatly contribute to understanding the process of hologram recording.

  17. Statistical characteristics of mechanical heart valve cavitation in accelerated testing.

    PubMed

    Wu, Changfu; Hwang, Ned H C; Lin, Yu-Kweng M

    2004-07-01

    Cavitation damage has been observed on mechanical heart valves (MHVs) undergoing accelerated testing. Cavitation itself can be modeled as a stochastic process, as it varies from beat to beat of the testing machine. This in-vitro study was undertaken to investigate the statistical characteristics of MHV cavitation. A 25-mm St. Jude Medical bileaflet MHV (SJM 25) was tested in an accelerated tester at various pulse rates, ranging from 300 to 1,000 bpm, with stepwise increments of 100 bpm. A miniature pressure transducer was placed near a leaflet tip on the inflow side of the valve, to monitor regional transient pressure fluctuations at instants of valve closure. The pressure trace associated with each beat was passed through a 70 kHz high-pass digital filter to extract the high-frequency oscillation (HFO) components resulting from the collapse of cavitation bubbles. Three intensity-related measures were calculated for each HFO burst: its time span; its local root-mean-square (LRMS) value; and the area enveloped by the absolute value of the HFO pressure trace and the time axis, referred to as cavitation impulse. These were treated as stochastic processes, of which the first-order probability density functions (PDFs) were estimated for each test rate. Both the LRMS value and cavitation impulse were log-normal distributed, and the time span was normal distributed. These distribution laws were consistent at different test rates. The present investigation was directed at understanding MHV cavitation as a stochastic process. The results provide a basis for establishing further the statistical relationship between cavitation intensity and time-evolving cavitation damage on MHV surfaces. These data are required to assess and compare the performance of MHVs of different designs.

  18. Estimation of heart rate and heart rate variability from pulse oximeter recordings using localized model fitting.

    PubMed

    Wadehn, Federico; Carnal, David; Loeliger, Hans-Andrea

    2015-08-01

    Heart rate variability is one of the key parameters for assessing the health status of a subject's cardiovascular system. This paper presents a local model fitting algorithm used for finding single heart beats in photoplethysmogram recordings. The local fit of exponentially decaying cosines of frequencies within the physiological range is used to detect the presence of a heart beat. Using 42 subjects from the CapnoBase database, the average heart rate error was 0.16 BPM and the standard deviation of the absolute estimation error was 0.24 BPM.

  19. Selective photoswitching of the binuclear spin crossover compound {[Fe(bt)(NCS)2]2(bpm)} into two distinct macroscopic phases.

    PubMed

    Moussa, N Ould; Molnár, G; Bonhommeau, S; Zwick, A; Mouri, S; Tanaka, K; Real, J A; Bousseksou, A

    2005-03-18

    The low-spin (LS-LS, S = 0) diamagnetic form of the binuclear spin crossover complex {[Fe(bt)(NCS)(2)](2)(bpm)} was selectively photoconverted into two distinct macroscopic phases at different excitation wavelengths (1342 or 647.1 nm). These long-lived metastable phases have been identified, respectively, as the symmetry-broken paramagnetic form (HS-LS, S = 2) and the antiferromagnetically coupled (HS-HS, S = 0) high-spin form of the compound. The selectivity may be explained by the strong coupling of the primary excited states to the paramagnetic state.

  20. Hill AFB, Utah Installation Restoration Program. Phase IIB, IRP Survey. Volume 1. Text. Volume 2. Appendices

    DTIC Science & Technology

    1984-09-11

    5 EPA 625 . Endosulfan sulfate wg/L 5 EPA 625 Chlordane pg/L * Toxaphene Pg/L * Acid Extractable Detection Analytical Compound Units Limit Method...ND ND ND ND 4,4’-DDT 5 ND ND ND ND Endosuif an sulfate 5 ND ND ND ND Chlordane* Toxa phene* Detection Acid Extractable Compound Limit M4-2 M4-6 14-9 Ge...Endosulfan sulfate 5 ND ND Chlordane * Toxaphene * Detection Acid Extractable Compound Limit BPM-1 BPM-2 2-Chlorophenol 2 ND ND 2-Nitrophenol 2 ND ND

  1. Multiple spatial modes based QKD over marine free-space optical channels in the presence of atmospheric turbulence.

    PubMed

    Sun, Xiaole; Djordjevic, Ivan B; Neifeld, Mark A

    2016-11-28

    We investigate a multiple spatial modes based quantum key distribution (QKD) scheme that employs multiple independent parallel beams through a marine free-space optical channel over open ocean. This approach provides the potential to increase secret key rate (SKR) linearly with the number of channels. To improve the SKR performance, we describe a back-propagation mode (BPM) method to mitigate the atmospheric turbulence effects. Our simulation results indicate that the secret key rate can be improved significantly by employing the proposed BPM-based multi-channel QKD scheme.

  2. Identifying the role of group III/IV muscle afferents in the carotid baroreflex control of mean arterial pressure and heart rate during exercise.

    PubMed

    Hureau, Thomas J; Weavil, Joshua C; Thurston, Taylor S; Broxterman, Ryan M; Nelson, Ashley D; Bledsoe, Amber D; Jessop, Jacob E; Richardson, Russell S; Wray, D Walter; Amann, Markus

    2018-04-15

    We investigated the contribution of group III/IV muscle afferents to carotid baroreflex resetting during electrically evoked (no central command) and voluntary (requiring central command) isometric knee extension exercise. Lumbar intrathecal fentanyl was used to attenuate the central projection of μ-opioid receptor-sensitive group III/IV leg muscle afferent feedback. Spontaneous carotid baroreflex control was assessed by loading and unloading the carotid baroreceptors with a variable pressure neck chamber. Group III/IV muscle afferents did not influence spontaneous carotid baroreflex responsiveness at rest or during exercise. Afferent feedback accounted for at least 50% of the exercise-induced increase in the carotid baroreflex blood pressure and heart rate operating points, adjustments that are critical for an appropriate cardiovascular response to exercise. These findings suggest that group III/IV muscle afferent feedback is, independent of central command, critical for the resetting of the carotid baroreflex blood pressure and heart rate operating points, but not for spontaneous baroreflex responsiveness. This study sought to comprehensively investigate the role of metabolically and mechanically sensitive group III/IV muscle afferents in carotid baroreflex responsiveness and resetting during both electrically evoked (EVO, no central command) and voluntary (VOL, requiring central command) isometric single-leg knee-extension (15% of maximal voluntary contraction; MVC) exercise. Participants (n = 8) were studied under control conditions (CTRL) and following lumbar intrathecal fentanyl injection (FENT) to inhibit μ-opioid receptor-sensitive lower limb muscle afferents. Spontaneous carotid baroreflex control of mean arterial pressure (MAP) and heart rate (HR) were assessed following rapid 5 s pulses of neck pressure (NP, +40 mmHg) or suction (NS, -60 mmHg). Resting MAP (87 ± 10 mmHg) and HR (70 ± 8 bpm) were similar between CTRL and FENT conditions (P > 0.4). In terms of spontaneous carotid baroreflex responsiveness, FENT did not alter the change in MAP or HR responses to NP (+13 ± 5 mmHg, P = 0.85; +9 ± 3 bpm; P = 0.99) or NS (-13 ± 5 mmHg, P = 0.99; -24 ± 11 bpm; P = 0.49) at rest or during either exercise protocol, which were of a remarkably similar magnitude to rest. In contrast, FENT administration reduced the exercise-induced resetting of the operating point for MAP and HR during both EVO (116 ± 10 mmHg to 100 ± 15 mmHg and 93 ± 14 bpm to 82 ± 10 bpm) and VOL (107 ± 13 mmHg to 100 ± 17 mmHg and 89 ± 10 bpm to 72 ± 10 bpm) exercise bouts. Together, these findings document that group III/IV muscle afferent feedback is critical for the resetting of the carotid baroreflex MAP and HR operating points, independent of exercise-induced changes in central command, but not for spontaneous carotid baroreflex responsiveness. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.

  3. Validation of a Standalone Smartphone Application for Measuring Heart Rate Using Imaging Photoplethysmography.

    PubMed

    Poh, Ming-Zher; Poh, Yukkee C

    2017-08-01

    The aim of this study was to determine the accuracy of a freely available smartphone application, Cardiio app (Cardiio, Inc., Cambridge, MA), to measure heart rate from the finger or face using imaging photoplethysmography, by comparing against an FDA-cleared pulse oximeter at rest, and after moderate to vigorous exercise. A total of 40 healthy adults participated in this study. Participants engaged in a period of rest, followed by 3 min of moderate to vigorous intensity cycling on a stationary bicycle. Heart rate measurements were obtained from both the finger and face of participants using the Cardiio app at rest, immediately after exercise, 1-2 min after exercise, and 2-3 min after exercise. Concurrent heart rate readings using an FDA-cleared finger pulse oximeter served as the reference measurement. There was a very strong agreement between heart rate measurements obtained using the Cardiio app and the pulse oximeter, both at rest (r = 0.99 for finger, r = 0.97 for face) and after exercise (r = 0.99 for finger, r = 0.97 for face). At rest, the accuracy of the Cardiio app was ±1.58 beats per minute (bpm) (or ±2.27%) using the finger mode and ±2.28 bpm (or ±3.17%) for the face mode, compared to the pulse oximeter. After moderate to vigorous exercise, the accuracy of the Cardiio app was ±2.97 bpm (or ±2.79%) using the finger mode and ±5.31 bpm (or ±4.50%) for the face mode, compared to the pulse oximeter. The Cardiio app provided accurate heart rate measurements from the finger and face, both at rest and after exercise.

  4. Modeling bipolar disorder in mice by increasing acetylcholine or dopamine: Chronic lithium treats most, but not all features

    PubMed Central

    van Enkhuizen, Jordy; Milienne-Petiot, Morgane; Geyer, Mark A.; Young, Jared W.

    2015-01-01

    Rationale Bipolar disorder (BD) is a disabling and life-threatening disease characterized by states of depression and mania. New and efficacious treatments have not been forthcoming partly due to a lack of well-validated models representing both facets of BD. Objectives We hypothesized that cholinergic- and dopaminergic-pharmacological manipulations would model depression and mania respectively, each attenuated by lithium treatment. Methods C57BL/6J mice received the acetylcholinesterase inhibitor physostigmine or saline before testing for ‘behavioral despair’ (immobility) in the tail-suspension test (TST) and forced-swim test (FST). Physostigmine effects on exploration and sensorimotor gating were assessed using the cross-species behavioral pattern monitor (BPM) and prepulse inhibition (PPI) paradigms. Other C57BL/6J mice received chronic lithium drinking water (300, 600, or 1200 mg/l) before assessing their effects alone in the BPM or with physostigmine on FST performance. Another group was tested with acute GBR12909 (dopamine transporter inhibitor) and chronic lithium (1000 mg/l) in the BPM. Results Physostigmine (0.03 mg/kg) increased immobility in the TST and FST without affecting activity, exploration, or PPI. Lithium (600 mg/l) resulted in low therapeutic serum concentrations and normalized the physostigmine-increased immobility in the FST. GBR12909 induced mania-like behavior in the BPM of which hyper-exploration was attenuated, though not reversed, after chronic lithium (1000 mg/ml). Conclusions Increased cholinergic levels induced depression-like behavior and hyperdopaminergia induced mania-like behavior in mice, while chronic lithium treated some, but not all, facets of these effects. These data support a cholinergic-monoaminergic mechanism for modeling BD aspects and provide a way to assess novel therapeutics. PMID:26141192

  5. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.

    2015-11-19

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the referencemore » cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2/3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Lastly, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.« less

  6. Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hulsart, R.; Cerniglia, P.; Michnoff, R.

    2011-03-28

    In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packetmore » size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.« less

  7. Modeling human orthostatic responses on the Moon and on Mars.

    PubMed

    Beck, Paula; Tank, Jens; Gauger, Peter; Beck, Luis E J; Zirngibl, Hubert; Jordan, Jens; Limper, Ulrich

    2018-06-01

    Since manned missions to the Moon and Mars are planned, we conducted active standing tests with lunar, Martian, terrestrial, and 1.8 loads of inertial resistance (+G z ) modeled through defined parabolic flight maneuvers. We hypothesized that the cardiovascular response to active standing is proportional to the +G z load. During partial-+G z parabolic flights, 14 healthy test subjects performed active stand-up maneuvers under 1 +G z , lunar (0.16 +G z ), Martian (0.38 +G z ), and hyper inertial resistance (1.8 +G z ) while heart rate and finger blood pressure were continuously monitored. We quantified amplitudes and timing of orthostatic response immediately following standing up. The maximum early heart rate increase was 21 (SD ± 10) bpm with lunar, 23 (± 11) bpm with Martian, 34 (± 17) bpm with terrestrial +G z , and 40 (± 11) bpm hyper +G z . The time to maximum heart rate increased gradually with increasing loads of inertial resistance. The transient blood pressure reduction was most pronounced with hyper +G z but did not differ significantly between lunar and Martian +G z . The mean arterial pressure nadir was reached significantly later with Martian and lunar compared to 1 +G z . Paradoxically, the time for blood pressure to recover was shortest with terrestrial +G z . While load of inertial resistance directly affects the magnitude of the transient blood pressure reduction and heart rate response to active standing, blood pressure stabilization is most rapidly attained during terrestrial +G z . The observation might suggest that the human cardiovascular system is tuned to cope with orthostatic stress on earth.

  8. Subjective and physiological effects, and expired carbon monoxide concentrations in frequent and occasional cannabis smokers following smoked, vaporized, and oral cannabis administration.

    PubMed

    Newmeyer, Matthew N; Swortwood, Madeleine J; Abulseoud, Osama A; Huestis, Marilyn A

    2017-06-01

    Although smoking is the most common cannabis administration route, vaporization and consumption of cannabis edibles are common. Few studies directly compare cannabis' subjective and physiological effects following multiple administration routes. Subjective and physiological effects, and expired carbon monoxide (CO) were evaluated in frequent and occasional cannabis users following placebo (0.001% Δ 9 -tetrahydrocannabinol [THC]), smoked, vaporized, and oral cannabis (6.9% THC, ∼54mg). Participants' subjective ratings were significantly elevated compared to placebo after smoking and vaporization, while only occasional smokers' ratings were significantly elevated compared to placebo after oral dosing. Frequent smokers' maximum ratings were significantly different between inhaled and oral routes, while no differences in occasional smokers' maximum ratings between active routes were observed. Additionally, heart rate increases above baseline 0.5h after smoking (mean 12.2bpm) and vaporization (10.7bpm), and at 1.5h (13.0bpm) and 3h (10.2bpm) after oral dosing were significantly greater than changes after placebo, with no differences between frequent and occasional smokers. Finally, smoking produced significantly increased expired CO concentrations 0.25-6h post-dose compared to vaporization. All participants had significant elevations in subjective effects after smoking and vaporization, but only occasional smokers after oral cannabis, indicating partial tolerance to subjective effects with frequent exposure. There were no differences in occasional smokers' maximum subjective ratings across the three active administration routes. Vaporized cannabis is an attractive alternative for medicinal administrations over smoking or oral routes; effects occur quickly and doses can be titrated with minimal CO exposure. These results have strong implications for safety and abuse liability assessments. Published by Elsevier B.V.

  9. Physiological work demands of Spanish wildland firefighters during wildfire suppression.

    PubMed

    Rodríguez-Marroyo, Jose A; López-Satue, Jorge; Pernía, Raul; Carballo, Belén; García-López, Juan; Foster, Carl; Villa, José G

    2012-02-01

    The aim of this study was to analyze the physiological demands and thermal strain of wildland firefighters during real wildfire suppression. The response of core temperature and heart rate (HR) were analyzed in 200 wildland firefighters during wildfire suppression activities of different duration: <1 h (n = 52), 1-3 h (n = 70), 3-5 h (n = 44), and >5 h (n = 34). The exercise workload (TRIMP), the physiological strain index (PSI), and cumulative heat strain index (CHSI) were calculated using the time spent in different intensity zones, the HR, and core temperature. Mean HR was significantly higher (P < 0.05) in wildfires <1 h (133 ± 2 bpm) and 1-3 h (128 ± 1 bpm) versus 3-5 h (120 ± 3 bpm) and >5 h (116 ± 32 bpm). The time spent in higher intensity zones increased (P < 0.05) when wildfire duration increased. TRIMP accumulation increased with wildfire duration (54.9 ± 3.2, 167.4 ± 5.9, 296.0 ± 8.3, 511.7 ± 12.8 in <1, 1-3, 3-5, and >5 h, respectively). Neither core temperature (37.4 ± 0.1°C) nor PSI (4.5 ± 0.2) were influenced by wildfire duration. The CHSI increased (p < 0.05) in the following order: <1 h (104 ± 23), 1-3 h (1,396 ± 275), 3-5 h (4,586 ± 387), and >5 h (10,703 ± 710). The results demonstrate the high work strain sustained by Spanish wildland firefighters during wildfire suppression. Both workload and CHSI increased with the wildfires duration although the pace of work was faster in wildfires of a shorter duration.

  10. Reliability and validity of the combined heart rate and movement sensor Actiheart.

    PubMed

    Brage, S; Brage, N; Franks, P W; Ekelund, U; Wareham, N J

    2005-04-01

    Accurate quantification of physical activity energy expenditure is a key part of the effort to understand disorders of energy metabolism. The Actiheart, a combined heart rate (HR) and movement sensor, is designed to assess physical activity in populations. To examine aspects of Actiheart reliability and validity in mechanical settings and during walking and running. In eight Actiheart units, technical reliability (coefficients of variation, CV) and validity for movement were assessed with sinusoid accelerations (0.1-20 m/s(2)) and for HR by simulated R-wave impulses (25-250 bpm). Agreement between Actiheart and ECG was determined during rest and treadmill locomotion (3.2-12.1 km/h). Walking and running intensity (in J/min/kg) was assessed with indirect calorimetry in 11 men and nine women (26-50 y, 20-29 kg/m(2)) and modelled from movement, HR, and movement + HR by multiple linear regression, adjusting for sex. Median intrainstrument CV was 0.5 and 0.03% for movement and HR, respectively. Corresponding interinstrument CV values were 5.7 and 0.03% with some evidence of heteroscedasticity for movement. The linear relationship between movement and acceleration was strong (R(2) = 0.99, P < 0.001). Simulated R-waves were detected within 1 bpm from 30 to 250 bpm. The 95% limits of agreement between Actiheart and ECG were -4.2 to 4.3 bpm. Correlations with intensity were generally high (R(2) > 0.84, P < 0.001) but significantly highest when combining HR and movement (SEE < 1 MET). The Actiheart is technically reliable and valid. Walking and running intensity may be estimated accurately but further studies are needed to assess validity in other activities and during free-living. The study received financial support from the Wellcome Trust and SB was supported by a scholarship from Unilever, UK.

  11. Estimating 'lost heart beats' rather than reductions in heart rate during the intubation of critically-ill children.

    PubMed

    Jones, Peter; Ovenden, Nick; Dauger, Stéphane; Peters, Mark J

    2014-01-01

    Reductions in heart rate occur frequently in children during critical care intubation and are currently considered the gold standard for haemodynamic instability. Our objective was to estimate loss of heart beats during intubation and compare this to reduction in heart rate alone whilst testing the impact of atropine pre-medication. Data were extracted from a prospective 2-year cohort study of intubation ECGs from critically ill children in PICU/Paediatric Transport. A three step algorithm was established to exclude variation in pre-intubation heart rate (using a 95%CI limit derived from pre-intubation heart rate variation of the children included), measure the heart rate over time and finally the estimate the numbers of lost beats. 333 intubations in children were eligible for inclusion of which 245 were available for analysis (74%). Intubations where the fall in heart rate was less than 50 bpm were accompanied almost exclusively by less than 25 lost beats (n = 175, median 0 [0-1]). When there was a reduction of >50 bpm there was a poor correlation with numbers of lost beats (n = 70, median 42 [15-83]). During intubation the median number of lost beats was 8 [1]-[32] when atropine was not used compared to 0 [0-0] when atropine was used (p<0.001). A reduction in heart rate during intubation of <50 bpm reliably predicted a minimal loss of beats. When the reduction in heart rate was >50 bpm the heart rate was poorly predictive of lost beats. A study looking at the relationship between lost beats and cardiac output needs to be performed. Atropine reduces both fall in heart rate and loss of beats. Similar area-under-the-curve methodology may be useful for estimating risk when biological parameters deviate outside normal range.

  12. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    PubMed

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  13. [Evaluation of Slavic continuity for electrocardiograph (ECG)-gated non-helical scan using multi detector-row computed tomography with 64 data acquisition system].

    PubMed

    Shiotani, Masataka; Ogawa, Masato; Watanabe, Ryo; Shinohara, Tamotsu

    2012-01-01

    Multi detector-row computed tomography with 64 data acquisition systems are widely used for coronary CT angiography with an electrocardiograph (ECG) gated helical scan (HS). Step and shoot with ECG gated non-helical scan (snap shot pulse: SSP) could reduce exposure dose but banding artifact-like discontinuity was observed between adjacent slabs on volume rendering (VR) and curved planner reconstruction (CPR). Therefore, we investigated the factors that influence continuity of VR and CPR images by calculating image properties of Z-axis direction of slab. The observer performance studies were performed for evaluating continuity of simulated blood vessels of VR and CPR images at simulated heart rates: 50, 55, 57 and 60 beat per minute (bpm). As a result, the value of SD at both slab edges in SSP were 20.5% lower than middle part of slab and differences of value of SD were up to 4.4 between adjacent slab edges. Slice thickness of both slab edges were 20.3% thinner than that of the peripheral part of slab. At the border of the adjacent slab, the position of the simulated blood vessel was shifted. VR images of SSP at 57 bpm was indicated as the highest score and HS was significantly superior to SSP at 55 and 60 bpm (p<0.05). In CPR images, there were no significant differences at all simulated heart rates. In conclusion, we considered that VR images of SSP were influenced heart rates except 57 bpm (resonance case) and there was little difference of visibility for discontinuity of both CPR images obtained by SSP and HS.

  14. Pedi-cap color change precedes a significant increase in heart rate during neonatal resuscitation.

    PubMed

    Blank, Doug; Rich, Wade; Leone, Tina; Garey, Donna; Finer, Neil

    2014-11-01

    Heart rate is the most important indicator of infant well-being during neonatal resuscitation. The Nellcor Pedi-Cap turns gold when exposed to exhaled gas with CO₂>15 mmHg. The aim of this study was to determine if Pedi-Cap gold color change during neonatal resuscitation precedes an increase in heart rate in babies with bradycardia receiving mask ventilation. This was a single-center retrospective review of video recordings and physiologic data of newborns with bradycardia receiving mask positive pressure ventilation during neonatal resuscitation. Subjects were included if the baby's HR<100 BPM within the first 90 s of resuscitation. The primary outcome was the change in HR prior to Pedi-Cap gold color change compared to the HR after Pedi-Cap gold color change. Forty-one newborns during the study period had HR<100 BPM and received mask positive pressure ventilation with a Pedi-Cap. The median heart rate 10s prior to Pedi-Cap gold color change was 75 BPM (IQR 62-85) and increased to 136 BPM (IQR 113-158) 30 s after gold color change (p<0.001). SpO₂ increased from 45 ± 17% prior to Pedi-Cap gold color change to 52 ± 17% 30s after gold color change (p=0.001). Colorimetric CO₂ detection during mask positive pressure ventilation in neonatal resuscitation precedes a significant increase in heart rate and SpO₂. The Pedi-Cap can be easily applied during resuscitation, requires no electricity, provides immediate feedback and may be a useful, simple tool early in resuscitation and may be especially useful in resource limited settings. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Rating of perceived exertion as a tool for prescribing and self regulating interval training: a pilot study

    PubMed Central

    Mantuani, SS; Neiva, CM; Verardi, CEL; Pessôa-Filho, DM

    2015-01-01

    The aim of the present study was to analyse the usefulness of the 6-20 rating of perceived exertion (RPE) scale for prescribing and self-regulating high-intensity interval training (HIT) in young individuals. Eight healthy young subjects (age = 27.5±6.7 years) performed maximal graded exercise testing to determine their maximal and reserve heart rate (HR). Subjects then performed two HIT sessions (20 min on a treadmill) prescribed and regulated by their HR (HR: 1 min at 50% alternated with 1 min at 85% of reserve HR) or RPE (RPE: 1 minute at the 9-11 level [very light-fairly light] alternated with 1 minute at the 15-17 level [hard-very hard]) in random order. HR response and walking/running speed during the 20 min of exercise were compared between sessions. No significant difference between sessions was observed in HR during low- (HR: 135±15 bpm; RPE: 138±20 bpm) and high-intensity intervals (HR: 168±15 bpm; RPE: 170±18 bpm). Walking/running speed during low- (HR: 5.7±1.2 km · h−1; RPE: 5.7±1.3 km · h−1) and high-intensity intervals (HR: 7.8±1.9 km · h−1; RPE: 8.2±1.7 km · h−1) was also not different between sessions. No significant differences were observed in HR response and walking/running speed between HIT sessions prescribed and regulated by HR or RPE. This finding suggests that the 6-20 RPE scale may be a useful tool for prescribing and self-regulating HIT in young subjects. PMID:26028809

  16. Hysteresis effect implicates calcium cycling as a mechanism of repolarization alternans.

    PubMed

    Walker, Mariah L; Wan, Xiaoping; Kirsch, Glenn E; Rosenbaum, David S

    2003-11-25

    T-wave alternans is due to alternation of membrane repolarization at the cellular level and is a risk factor for sudden cardiac death. Recently, a hysteresis effect has been reported in patients whereby T-wave alternans, once induced by rapid heart rate, persists even when heart rate is subsequently slowed. We hypothesized that alternans hysteresis is an intrinsic property of cardiac myocytes, directly related to an underlying mechanism for repolarization alternans that involves intracellular calcium cycling. Stepwise pacing was used to induce alternans in Langendorff-perfused guinea pig hearts from which optical action potentials were recorded simultaneously at 256 ventricular sites with voltage-sensitive dyes and in whole-cell patch-clamped cardiac myocytes treated with or without BAPTA-AM (1,2-bis[2-aminophenoxy]ethane-N,N,N',N'-tetraacetic acid tetrakis [acetoxymethyl ester]). Alternans hysteresis was observed in every isolated heart: threshold heart rate for alternans was 280+/-12 bpm, but during subsequent deceleration of pacing, alternans persisted to significantly slower heart rates (238+/-5 bpm, P<0.05). Optical mapping showed that this effect also applied to the threshold for spatially discordant alternans (313+/-2.2 bpm during acceleration versus 250+/-6.6 bpm during deceleration, P<0.05). Alternans hysteresis was also observed in isolated cardiac myocytes. Moreover, calcium chelation by BAPTA-AM raised the threshold for alternans and inhibited hysteresis in a dose-dependent manner with no effect on baseline action potential duration. Alternans hysteresis is an intrinsic property of cardiac myocytes that can lead to persistence of arrhythmogenic discordant alternans even after heart rate is slowed. These results also support an important underlying role of calcium cycling in the mechanism of alternans.

  17. WISE-2005: Integrative cardiovascular responses with LBNP during 60-day bed rest in women

    NASA Astrophysics Data System (ADS)

    Hughson, R. L.; Kerbeci, P.; Arbeille, P.; Mattar, L.; Shoemaker, J. K.

    2005-08-01

    During 2005, 24 women will take part in the Women International Space-simulation for Exploration (WISE). In this paper we report on the first phase that studied 4 Exercise (EX+LBNP), 4 nutrition (NUT), and 4 no countermeasure control (CON) subjects. The EX+LBNP group completed regular exercise on a treadmill inside LBNP, flywheel resistive exercise and static periods of LBNP, and had recovery days. The NUT group received daily protein supplements. Integrative cardiovascular responses were obtained and here we report data for heart rate during LBNP, blood volume and angiotensin II. LBNP was applied at 0, -10, -20 and -30 mmHg for 2-minutes for each stage. Blood was sampled pre- bed rest and on HDT-60. After 60-days head down bed rest, HR in the CON group increased by 6.1±2.8 bpm at rest and by 20.7±5.0 bpm at -30 mmHg LBNP. The EX+LBNP group had increases of 3.6±5.6 and 11.6±5.4 bpm, while the NUT group HR increased 2.6±3.1 and 9.4±3.6 bpm. The EX+LBNP group had almost no change in blood volume or plasma angiotensin II from pre-bed rest to HDT60, while both the CON and NUT groups had larger increases in plasma volume and almost double concentrations of angiotensin II. These data show a positive effect in the EX+LBNP group on the heart rate response as well as an unexpected possible benefit in the NUT group. Further studies are required to confirm possible cardiovascular benefits of the protein supplement.

  18. WISE-2005: Integrative Cardiovascular Responses with LBNP during 60-Day Bed Rest in Women

    NASA Technical Reports Server (NTRS)

    Hughson, R. L.; Kerbeci, P.; Arbeille, Ph.; Mattar, L.; Shoemaker, J. K.

    2005-01-01

    During 2005, 24 women will take part in the Women International Space-simulation for Exploration (WISE). In this paper we report on the first phase that studied 4 Exercise (EX+LBNP), 4 nutrition (NUT), and 4 no countermeasure control (CON) subjects. The EX+LBNP group completed regular exercise on a treadmill inside LBNP, flywheel resistive exercise and static periods of LBNP, and had recovery days. The NUT group received daily protein supplements. Integrative cardiovascular responses were obtained and here we report data for heart rate during LBNP, blood volume and angiotensin 11. LBNP was applied at 0, -10, -20 and -30 mmHg for 2-minutes for each stage. Blood was sampled prebed rest and on HDT-60. After 60-days head down bed rest, HR in the CON group increased by 6.1+/-2.8 bpm at rest and by 20.7+/-5.0 bpm at -30 mmHg LBNP. The EX+LBNP group had increases of 3.6+/-5.6 and 11.6+/-5.4 bpm, while the NUT group HR increased 2.6+/-3.1 and 9.4+/-3.6 bpm. The EX+LBNP group had almost no change in blood volume or plasma angiotensin II from pre-bed rest to HDT60, while both the CON and NUT groups had larger increases in plasma volume and almost double concentrations of angiotensin II. These data show a positive effect in the EX+LBNP group on the heart rate response as well as an unexpected possible benefit in the NUT group. Further studies are required to confirm possible cardiovascular benefits of the protein supplement.

  19. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    NASA Astrophysics Data System (ADS)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.; Lefevre, T.; Lunin, A.; Lyapin, A.; Søby, L.; Towler, J.; Wendt, M.

    2015-11-01

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2 /3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  20. Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT.

    PubMed

    Sommer, Wieland H; Albrecht, Edda; Bamberg, Fabian; Schenzle, Jan C; Johnson, Thorsten R; Neumaier, Klement; Reiser, Maximilian F; Nikolaou, Konstatin

    2010-12-01

    The objective of this study was to compare image quality and radiation dose between high-pitch and established retrospectively and prospectively gated cardiac CT protocols using an Alderson-Rando phantom and a set of patients. An anthropomorphic Alderson-Rando phantom equipped with thermoluminiscent detectors and a set of clinical patients underwent the following cardiac CT protocols: high-pitch acquisition (pitch 3.4), prospectively triggered acquisition, and retrospectively gated acquisition (pitch 0.2). For patients with sinus rhythm below 65 beats per minute (bpm), high-pitch protocol was used, whereas for patients in sinus rhythm between 65 and 100 bpm, prospective triggering was used. Patients with irregular heart rates or heart rates of ≥ 100 bpm, were examined using retrospectively gated acquisition. Evaluability of coronary artery segments was determined, and effective radiation dose was derived from the phantom study. In the phantom study, the effective radiation dose as determined with thermoluminescent detector (TLD) measurements was lowest in the high-pitch acquisition (1.21, 3.12, and 11.81 mSv, for the high-pitch, the prospectively triggered, and the retrospectively gated acquisition, respectively). There was a significant difference with respect to the percentage of motion-free coronary artery segments (99%, 87%, and 92% for high-pitch, prospectively triggered, and retrospectively gated, respectively (p < 0.001), whereas image noise was lowest for the high-pitch protocol (p < 0.05). High-pitch scans have the potential to reduce radiation dose up to 61.2% and 89.8% compared with prospectively triggered and retrospectively gated scans. High-pitch protocols lead to excellent image quality when used in patients with stable heart rates below 65 bpm.

  1. Theoretical design strategies of bipolar membrane fuel cell with enhanced self-humidification behavior

    NASA Astrophysics Data System (ADS)

    Li, Qiushi; Gong, Jian; Peng, Sikan; Lu, Shanfu; Sui, Pang-Chieh; Djilali, Ned; Xiang, Yan

    2016-03-01

    The bipolar membrane fuel cells (BPMFCs), which have a unique acid-alkaline jointed membrane electrode assembly (MEA) structure, have demonstrated their great potential for self-humidification during operation. Although the self-humidification ability of such bipolar membranes (BPMs) has recently been validated by a one-dimensional BPM model, the transport mechanism and the formation of self-humidification in the MEAs are not well understood. In the present study, a two-dimensional cross-channel MEA model is developed to elucidate the mechanisms and enhancement of water transport on self-humidification with comprehensive consideration of the three electrochemical reaction zones. The water-formation interface model has been successfully investigated by theoretical and experimental interface reaction kinetics, streamlines of water flux present the formation process and mechanism of self-humidification. A critical current (voltage) value, beyond which self-humidification is initiated, is identified. It is also found that such critical current (voltage) can be adjusted by changing the membrane thickness and the water uptake property of the ionomer. It is concluded that fabricating BPMs with proper membrane thickness and water uptake property are effective strategies to enhance the water management and cell performance in BPMFCs.

  2. Alcoholics' selective attention to alcohol stimuli: automated processing?

    PubMed

    Stormark, K M; Laberg, J C; Nordby, H; Hugdahl, K

    2000-01-01

    This study investigated alcoholics' selective attention to alcohol words in a version of the Stroop color-naming task. Alcoholic subjects (n = 23) and nonalcoholic control subjects (n = 23) identified the color of Stroop versions of alcohol, emotional, neutral and color words. Manual reaction times (RTs), skin conductance responses (SCRs) and heart rate (HR) were recorded. Alcoholics showed overall longer RTs than controls while both groups were slower in responding to the incongruent color words than to the other words. Alcoholics showed longer RTs to both alcohol (1522.7 milliseconds [ms]) and emotional words (1523.7 ms) than to neutral words (1450.8 ms) which suggests that the content of these words interfered with the ability to attend to the color of the words. There was also a negative correlation (r = -.41) between RT and response accuracy to alcohol words for the alcoholics, reflecting that the longer time the alcoholics used to respond to the color of the alcohol words, the more incorrect their responses were. The alcoholics also showed significantly greater SCRs to alcohol words (0.16 microSiemens) than to any of the other words (ranging from 0.04-0.08 microSiemens), probably reflecting the emotional significance of the alcohol words. Finally, the alcoholics evidenced smaller HR acceleration to alcohol (1.9 delta bpm) compared to neutral (2.8 delta bpm), which could be related to difficulties alcoholics experience in terminating their attention to the alcohol words. These findings indicate that it is difficult for alcoholics to regulate their attention to alcohol stimuli, suggesting that alcoholics' processing of alcohol information is automated.

  3. Dosimetric impact of a change in breathing period on VMAT stereotactic ablative body radiotherapy

    NASA Astrophysics Data System (ADS)

    Olding, T.; Alexander, KM

    2017-05-01

    The dosimetric impact of a change in breathing period during treatment was assessed for a volumetric modulated arc therapy (VMAT) stereotactic ablative radiotherapy (SABR) lung plan optimized according to our centre’s planning protocol. Plan delivery was evaluated at three breathing rates ranging from 7 to 23 breaths-per-minute (BPM) against the planning anatomy (15 BPM) calculated dose. Dynamic ion chamber, EBT3 film and Fricke-xylenol orange-gelatin (FXG) gel measurements were acquired using a motion phantom with appropriate inserts for each dosimeter. The results show good agreement between measured and calculated plan dose within the internal gross tumour volume (IGTV) target.

  4. Design of optical seven-segment decoder using Pockel's effect inside lithium niobate-based waveguide

    NASA Astrophysics Data System (ADS)

    Pal, Amrindra; Kumar, Santosh; Sharma, Sandeep

    2017-01-01

    Seven-segment decoder is a device that allows placing digital information from many inputs to many outputs optically, having 11 Mach-Zehnder interferometers (MZIs) for their implementation. The layout of the circuit is implemented to fit the electrical method on an optical logic circuit based on the beam propagation method (BPM). Seven-segment decoder is proposed using electro-optic effect inside lithium niobate-based MZIs. MZI structures are able to switch an optical signal to a desired output port. It consists of a mathematical explanation about the proposed device. The BPM is also used to analyze the study.

  5. Non-contact Doppler radar monitoring of cardiorespiratory motion for Siberian sturgeon.

    PubMed

    Hafner, Noah; Massagram, Wansuree; Lubecke, Victor

    2012-01-01

    This paper presents the first reported use of Doppler radar to remotely sense heart and ventilation rates of fish. The Radar reported 35 to 40 BPM heart rate and 115 to 145 BPM ventilation rates for Siberian Sturgeon, with agreement from a video reference. Conventional fish vital signs measurements require invasive surgery and human handling--these are problematic for large scale monitoring, for measuring deep sea fish, and other situations which preclude human interaction with each individual subject. These results show a useful application of radar to augment existing cardiovascular and ventilatory activity sensing techniques and enable monitoring in a wider range of situations.

  6. Maternal bradycardia occurring prior to onset of HELLP syndrome in a woman with pre-eclampsia.

    PubMed

    Hosokawa, Ami; Umazume, Takeshi; Yamada, Takahiro; Minakami, Hisanori

    2017-05-13

    A 36-year-old nulliparous woman developed pre-eclampsia at gestational week (GW) 28 -6/7 Cardiac status was checked regularly. Heart rate of 93 beats per minute (bpm) with left atrial diameter (LAD) of 35 mm, left ventricular hypertrophy and inferior vena cava diameter (IVCD) of 8 mm at GW 32 -0/7 decreased to 48 bpm with an expanded IVCD to 25 mm, dilated left atrium (LAD to 39 mm), increased pulmonary arterial pressure, increased systemic vascular resistance (approximate 3000  dyn s/cm 5 ) and biphasic intrarenal venous flow pattern 3.5 hours prior to childbirth at GW 32 -3/7 Epigastralgia, tachycardia (160 bpm) and marked hypertension (201/111 mm Hg) occurring 2 hours after echocardiography necessitated caesarean section, with subsequent development of HELLP syndrome. Acute fluid shift from the splanchnic vasculature to central vasculature may have occurred causing HELLP syndrome as a result from vasospasm associated with sympathetic hyperactivity. The cause of bradycardia prior to tachycardia remains unclear. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Boundary particle method for Laplace transformed time fractional diffusion equations

    NASA Astrophysics Data System (ADS)

    Fu, Zhuo-Jia; Chen, Wen; Yang, Hai-Tian

    2013-02-01

    This paper develops a novel boundary meshless approach, Laplace transformed boundary particle method (LTBPM), for numerical modeling of time fractional diffusion equations. It implements Laplace transform technique to obtain the corresponding time-independent inhomogeneous equation in Laplace space and then employs a truly boundary-only meshless boundary particle method (BPM) to solve this Laplace-transformed problem. Unlike the other boundary discretization methods, the BPM does not require any inner nodes, since the recursive composite multiple reciprocity technique (RC-MRM) is used to convert the inhomogeneous problem into the higher-order homogeneous problem. Finally, the Stehfest numerical inverse Laplace transform (NILT) is implemented to retrieve the numerical solutions of time fractional diffusion equations from the corresponding BPM solutions. In comparison with finite difference discretization, the LTBPM introduces Laplace transform and Stehfest NILT algorithm to deal with time fractional derivative term, which evades costly convolution integral calculation in time fractional derivation approximation and avoids the effect of time step on numerical accuracy and stability. Consequently, it can effectively simulate long time-history fractional diffusion systems. Error analysis and numerical experiments demonstrate that the present LTBPM is highly accurate and computationally efficient for 2D and 3D time fractional diffusion equations.

  8. Performance of a Nanometer Resolution BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walston, S.; Chung, C.; Fitsos, P.

    2007-04-24

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Acceleratormore » Test Facility (ATF) for testing with its ultra-low emittance beam. The three BPMs are rigidly mounted inside an alignment frame on variable-length struts which allow movement in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a calibration algorithm which is immune to beam jitter. To date, we have been able to demonstrate a resolution of approximately 20 nm over a dynamic range of +/- 20 microns. We report on the progress of these ongoing tests.« less

  9. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    PubMed

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  10. ZEP520A cold-development technique and tool for ultimate resolution to fabricate 1Xnm bit pattern EB master mold for nano-imprinting lithography for HDD/BPM development

    NASA Astrophysics Data System (ADS)

    Kobayashi, Hideo; Iyama, Hiromasa

    2012-06-01

    Poor solvent developers are effective for resolution enhancement on a polymer-type EB resist such as ZEP520A. Another way is to utilize "cold-development" technique which was accomplished by a dip-development technique usually. We then designed and successfully built a single-wafer spin-development tool for the cold-development down to -10degC in order to dissolve difficulties of the dip-development. The cold-development certainly helped improve ZEP520A resolution and hole CD size uniformity, and achieved 35nm pitch BPM patterns with the standard developer ZED-N50, but not 25nm pitch yet. By employing a poor solvent mixture of iso-Propyl Alcohol (IPA) and Fluoro-Carbon (FC), 25nm pitch BPM patterns were accomplished. However, the cold-development showed almost no improvement on the IPA/FC mixture developer solvent. This paper describes cold-development technique and a tool, as well as its results, for ZEP520A resolution enhancement to fabricate 1Xnm bits (holes) for EB master-mold for Nano-Imprinting Lithography for 1Tbit/inch2 and 25nm pitch Bit Patterned Media development.

  11. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review

    PubMed Central

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-01-01

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient’s quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up. PMID:28603590

  12. Performance of a reentrant cavity beam position monitor

    NASA Astrophysics Data System (ADS)

    Simon, Claire; Luong, Michel; Chel, Stéphane; Napoly, Olivier; Novo, Jorge; Roudier, Dominique; Rouvière, Nelly; Baboi, Nicoleta; Mildner, Nils; Nölle, Dirk

    2008-08-01

    The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs). In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryomodule, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10μm and has the possibility to perform bunch to bunch measurements for the x-ray free electron laser (X-FEL) and the International Linear Collider (ILC). Its other features are a small size of the rf cavity, a large aperture (78 mm), and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH), at Deutsches Elektronen-Synchrotron (DESY) and demonstrated its operation at cryogenic temperature inside a cryomodule. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4μm over a dynamic range ±5mm in single bunch.

  13. Systemic hypotensive effects of testosterone are androgen structure-specific and neuronal nitric oxide synthase-dependent

    PubMed Central

    Perusquía, Mercedes; Greenway, Clayton D.; Perkins, Lisa M.

    2015-01-01

    Testosterone (TES) and other androgens exert a direct vasorelaxing action on the vasculature in vitro that is structurally specific and independent of cytosolic androgen receptor (AR). The effects of intravenous androgen infusions on mean arterial blood pressure (BP) and heart rate (HR) were determined in conscious, unrestrained, chronically catheterized, ganglionically blocked (hexamethonium, HEX; 30 mg/kg ip) male Sprague-Dawley (SD) and testicular-feminized male (Tfm; AR-deficient) rats, 16–20 wk of age. BP and HR were recorded at baseline and with increasing doses of androgens (0.375–6.00 μmol·kg−1·min−1 iv; 10 min/dose). Data are expressed as means ± SE (n = 5–8 rats/group). In SD rats, baseline BP and HR averaged 103 ± 4 mmHg and 353 ± 12 beats/min (bpm). TES produced a dose-dependent reduction in BP to a low of 87 ± 4 mmHg (Δ16%), while HR was unchanged (354 ± 14 bpm). Neither BP (109 ± 3 mmHg) nor HR (395 ± 13 bpm) were altered by vehicle (10% EtOH in 0.9% saline; 0.15 ml·kg−1·min−1, iv). In Tfm, TES produced a similar reduction in BP (99 ± 3 to 86 ± 3 mmHg, Δ13%); HR was unchanged (369 ± 18 bpm). In SD, 5β-dihydrotestosterone (genomically inactive metabolite) produced a greater reduction in BP than TES (102 ± 2 to 79 ± 2 mmHg, Δ23%); HR was unchanged (361 ± 9). A 20-μg iv bolus of sodium nitroprusside in both SD and Tfm rats reduced BP 30–40 mmHg, while HR was unchanged, confirming blockade by HEX. Pretreatment of SD rats with neuronal nitric oxide synthase (nNOS) inhibitor (S-methyl-thiocitrulline, SMTC; 20 μg·kg−1·min−1 × 30 min) abolished the hypotensive effects of TES infusion on BP (104 ± 2 vs. 101 ± 2 mmHg) and HR (326 ± 11 vs. 324 ± 8 bpm). These data suggest the systemic hypotensive effect of TES and other androgens involves a direct vasodilatory action on the peripheral vasculature which, like the effect observed in isolated arteries, is structurally specific and AR-independent, and involves activation of nNOS. PMID:25947172

  14. Effects of renal sympathetic denervation on exercise blood pressure, heart rate, and capacity in patients with resistant hypertension.

    PubMed

    Ewen, Sebastian; Mahfoud, Felix; Linz, Dominik; Pöss, Janine; Cremers, Bodo; Kindermann, Ingrid; Laufs, Ulrich; Ukena, Christian; Böhm, Michael

    2014-04-01

    Renal denervation reduces office blood pressure in patients with resistant hypertension. This study investigated the effects of renal denervation on blood pressure, heart rate, and chronotropic index at rest, during exercise, and at recovery in 60 patients (renal denervation group=50, control group=10) with resistant hypertension using a standardized bicycle exercise test protocol performed 6 and 12 months after renal denervation. After renal denervation, exercise blood pressure at rest was reduced from 158±3/90±2 to 141±3/84±4 mm Hg (P<0.001 for systolic blood pressure/P=0.007 for diastolic blood pressure) after 6 months and 139±3/83±4 mm Hg (P<0.001/P=0.022) after 12 months. Exercise blood pressure tended to be lower at all stages of exercise at 6- and 12-month follow-up in patients undergoing renal denervation, although reaching statistical significance only at mild-to-moderate exercise levels (75-100 W). At recovery after 1 minute, blood pressure decreased from 201±4/95±2 to 177±4/88±2 (P<0.001/P=0.066) and 188±6/86±2 mm Hg (P=0.059/P=0.01) after 6 and 12 months, respectively. Heart rate was reduced after renal denervation from 71±3 bpm at rest, 128±5 bpm at maximum workload, and 96±5 bpm at recovery after 1 minute to 66±2 (P<0.001), 115±5 (P=0.107), and 89±3 bpm (P=0.008) after 6 months and to 69±3 (P=0.092), 122±7 (P=0.01), and 93±4 bpm (P=0.032) after 12 months. Mean exercise time increased from 6.59±0.33 to 8.4±0.32 (P<0.001) and 9.0±0.41 minutes (P=0.008), and mean workload increased from 93±2 to 100±2 (P<0.001) and 101±3 W (P=0.007) at 6- and 12-month follow-up, respectively. No changes were observed in the control group. In conclusion, renal denervation reduced blood pressure and heart rate during exercise, improved mean workload, and increased exercise time without impairing chronotropic competence.

  15. Caffeine Ingestion Increases Estimated Glycolytic Metabolism during Taekwondo Combat Simulation but Does Not Improve Performance or Parasympathetic Reactivation.

    PubMed

    Lopes-Silva, João Paulo; Silva Santos, Jonatas Ferreira da; Branco, Braulio Henrique Magnani; Abad, César Cavinato Cal; Oliveira, Luana Farias de; Loturco, Irineu; Franchini, Emerson

    2015-01-01

    The aim of this study was to evaluate the effect of caffeine ingestion on performance and estimated energy system contribution during simulated taekwondo combat and on post-exercise parasympathetic reactivation. Ten taekwondo athletes completed two experimental sessions separated by at least 48 hours. Athletes consumed a capsule containing either caffeine (5 mg∙kg-1) or placebo (cellulose) one hour before the combat simulation (3 rounds of 2 min separated by 1 min passive recovery), in a double-blind, randomized, repeated-measures crossover design. All simulated combat was filmed to quantify the time spent fighting in each round. Lactate concentration and rating of perceived exertion were measured before and after each round, while heart rate (HR) and the estimated contribution of the oxidative (WAER), ATP-PCr (WPCR), and glycolytic (W[La-]) systems were calculated during the combat simulation. Furthermore, parasympathetic reactivation after the combat simulation was evaluated through 1) taking absolute difference between the final HR observed at the end of third round and the HR recorded 60-s after (HRR60s), 2) taking the time constant of HR decay obtained by fitting the 6-min post-exercise HRR into a first-order exponential decay curve (HRRτ), or by 3) analyzing the first 30-s via logarithmic regression analysis (T30). Caffeine ingestion increased estimated glycolytic energy contribution in relation to placebo (12.5 ± 1.7 kJ and 8.9 ± 1.2 kJ, P = 0.04). However, caffeine did not improve performance as measured by attack number (CAF: 26. 7 ± 1.9; PLA: 27.3 ± 2.1, P = 0.48) or attack time (CAF: 33.8 ± 1.9 s; PLA: 36.6 ± 4.5 s, P = 0.58). Similarly, RPE (CAF: 11.7 ± 0.4 a.u.; PLA: 11.5 ± 0.3 a.u., P = 0.62), HR (CAF: 170 ± 3.5 bpm; PLA: 174.2 bpm, P = 0.12), oxidative (CAF: 109.3 ± 4.5 kJ; PLA: 107.9 kJ, P = 0.61) and ATP-PCr energy contributions (CAF: 45.3 ± 3.4 kJ; PLA: 46.8 ± 3.6 kJ, P = 0.72) during the combat simulation were unaffected. Furthermore, T30 (CAF: 869.1 ± 323.2 s; PLA: 735.5 ± 232.2 s, P = 0.58), HRR60s (CAF: 34 ± 8 bpm; PLA: 38 ± 9 bpm, P = 0.44), HRRτ (CAF: 182.9 ± 40.5 s, PLA: 160.3 ± 62.2 s, P = 0.23) and HRRamp (CAF: 70.2 ± 17.4 bpm; PLA: 79.2 ± 17.4 bpm, P = 0.16) were not affected by caffeine ingestion. Caffeine ingestion increased the estimated glycolytic contribution during taekwondo combat simulation, but this did not result in any changes in performance, perceived exertion or parasympathetic reactivation.

  16. Caffeine Ingestion Increases Estimated Glycolytic Metabolism during Taekwondo Combat Simulation but Does Not Improve Performance or Parasympathetic Reactivation

    PubMed Central

    2015-01-01

    Objectives The aim of this study was to evaluate the effect of caffeine ingestion on performance and estimated energy system contribution during simulated taekwondo combat and on post-exercise parasympathetic reactivation. Methods Ten taekwondo athletes completed two experimental sessions separated by at least 48 hours. Athletes consumed a capsule containing either caffeine (5 mg∙kg-1) or placebo (cellulose) one hour before the combat simulation (3 rounds of 2 min separated by 1 min passive recovery), in a double-blind, randomized, repeated-measures crossover design. All simulated combat was filmed to quantify the time spent fighting in each round. Lactate concentration and rating of perceived exertion were measured before and after each round, while heart rate (HR) and the estimated contribution of the oxidative (WAER), ATP-PCr (WPCR), and glycolytic (W[La-]) systems were calculated during the combat simulation. Furthermore, parasympathetic reactivation after the combat simulation was evaluated through 1) taking absolute difference between the final HR observed at the end of third round and the HR recorded 60-s after (HRR60s), 2) taking the time constant of HR decay obtained by fitting the 6-min post-exercise HRR into a first-order exponential decay curve (HRRτ), or by 3) analyzing the first 30-s via logarithmic regression analysis (T30). Results Caffeine ingestion increased estimated glycolytic energy contribution in relation to placebo (12.5 ± 1.7 kJ and 8.9 ± 1.2 kJ, P = 0.04). However, caffeine did not improve performance as measured by attack number (CAF: 26. 7 ± 1.9; PLA: 27.3 ± 2.1, P = 0.48) or attack time (CAF: 33.8 ± 1.9 s; PLA: 36.6 ± 4.5 s, P = 0.58). Similarly, RPE (CAF: 11.7 ± 0.4 a.u.; PLA: 11.5 ± 0.3 a.u., P = 0.62), HR (CAF: 170 ± 3.5 bpm; PLA: 174.2 bpm, P = 0.12), oxidative (CAF: 109.3 ± 4.5 kJ; PLA: 107.9 kJ, P = 0.61) and ATP-PCr energy contributions (CAF: 45.3 ± 3.4 kJ; PLA: 46.8 ± 3.6 kJ, P = 0.72) during the combat simulation were unaffected. Furthermore, T30 (CAF: 869.1 ± 323.2 s; PLA: 735.5 ± 232.2 s, P = 0.58), HRR60s (CAF: 34 ± 8 bpm; PLA: 38 ± 9 bpm, P = 0.44), HRRτ (CAF: 182.9 ± 40.5 s, PLA: 160.3 ± 62.2 s, P = 0.23) and HRRamp (CAF: 70.2 ± 17.4 bpm; PLA: 79.2 ± 17.4 bpm, P = 0.16) were not affected by caffeine ingestion. Conclusions Caffeine ingestion increased the estimated glycolytic contribution during taekwondo combat simulation, but this did not result in any changes in performance, perceived exertion or parasympathetic reactivation. PMID:26539982

  17. Postcaesarean open-heart surgery for Streptococcus sanguinis infective endocarditis

    PubMed Central

    Kongwattanakul, Kiattisak; Tribuddharat, Sirirat; Prathanee, Sompop; Pachirat, Orathai

    2013-01-01

    A 33-week pregnant (gravida 3), 29-year-old woman was transferred for management of Streptococcus sanguinis infective endocarditis. A vegetation was present on the posterior leaflet of the mitral valve with moderate mitral regurgitation. On admission (day 1), the ultrasound examination revealed splenic abscesses and retarded intrauterine growth albeit with normal vessels. The fetal heart rate was 140 bpm. On day 11, the baby was delivered by Caesarean, and then the mother underwent tubal ligation followed by a mitral valve repair. The splenic abscess was treated with antibiotics. The woman was clinically stable and recovered uneventfully. This successful outcome was achieved by a strategic (optimal and sequential) timeline for selecting the mode of delivery and type of mitral valve correction. PMID:24234426

  18. Automated generation of patient-tailored electronic care pathways by translating computer-interpretable guidelines into hierarchical task networks.

    PubMed

    González-Ferrer, Arturo; ten Teije, Annette; Fdez-Olivares, Juan; Milian, Krystyna

    2013-02-01

    This paper describes a methodology which enables computer-aided support for the planning, visualization and execution of personalized patient treatments in a specific healthcare process, taking into account complex temporal constraints and the allocation of institutional resources. To this end, a translation from a time-annotated computer-interpretable guideline (CIG) model of a clinical protocol into a temporal hierarchical task network (HTN) planning domain is presented. The proposed method uses a knowledge-driven reasoning process to translate knowledge previously described in a CIG into a corresponding HTN Planning and Scheduling domain, taking advantage of HTNs known ability to (i) dynamically cope with temporal and resource constraints, and (ii) automatically generate customized plans. The proposed method, focusing on the representation of temporal knowledge and based on the identification of workflow and temporal patterns in a CIG, makes it possible to automatically generate time-annotated and resource-based care pathways tailored to the needs of any possible patient profile. The proposed translation is illustrated through a case study based on a 70 pages long clinical protocol to manage Hodgkin's disease, developed by the Spanish Society of Pediatric Oncology. We show that an HTN planning domain can be generated from the corresponding specification of the protocol in the Asbru language, providing a running example of this translation. Furthermore, the correctness of the translation is checked and also the management of ten different types of temporal patterns represented in the protocol. By interpreting the automatically generated domain with a state-of-art HTN planner, a time-annotated care pathway is automatically obtained, customized for the patient's and institutional needs. The generated care pathway can then be used by clinicians to plan and manage the patients long-term care. The described methodology makes it possible to automatically generate patient-tailored care pathways, leveraging an incremental knowledge-driven engineering process that starts from the expert knowledge of medical professionals. The presented approach makes the most of the strengths inherent in both CIG languages and HTN planning and scheduling techniques: for the former, knowledge acquisition and representation of the original clinical protocol, and for the latter, knowledge reasoning capabilities and an ability to deal with complex temporal and resource constraints. Moreover, the proposed approach provides immediate access to technologies such as business process management (BPM) tools, which are increasingly being used to support healthcare processes. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Perspectives of human verification via binary QRS template matching of single-lead and 12-lead electrocardiogram.

    PubMed

    Krasteva, Vessela; Jekova, Irena; Schmid, Ramun

    2018-01-01

    This study aims to validate the 12-lead electrocardiogram (ECG) as a biometric modality based on two straightforward binary QRS template matching characteristics. Different perspectives of the human verification problem are considered, regarding the optimal lead selection and stability over sample size, gender, age, heart rate (HR). A clinical 12-lead resting ECG database, including a population of 460 subjects with two-session recordings (>1 year apart) is used. Cost-effective strategies for extraction of personalized QRS patterns (100ms) and binary template matching estimate similarity in the time scale (matching time) and dissimilarity in the amplitude scale (mismatch area). The two-class person verification task, taking the decision to validate or to reject the subject identity is managed by linear discriminant analysis (LDA). Non-redundant LDA models for different lead configurations (I,II,III,aVF,aVL,aVF,V1-V6) are trained on the first half of 230 subjects by stepwise feature selection until maximization of the area under the receiver operating characteristic curve (ROC AUC). The operating point on the training ROC at equal error rate (EER) is tested on the independent dataset (second half of 230 subjects) to report unbiased validation of test-ROC AUC and true verification rate (TVR = 100-EER). The test results are further evaluated in groups by sample size, gender, age, HR. The optimal QRS pattern projection for single-lead ECG biometric modality is found in the frontal plane sector (60°-0°) with best (Test-AUC/TVR) for lead II (0.941/86.8%) and slight accuracy drop for -aVR (-0.017/-1.4%), I (-0.01/-1.5%). Chest ECG leads have degrading accuracy from V1 (0.885/80.6%) to V6 (0.799/71.8%). The multi-lead ECG improves verification: 6-chest (0.97/90.9%), 6-limb (0.986/94.3%), 12-leads (0.995/97.5%). The QRS pattern matching model shows stable performance for verification of 10 to 230 individuals; insignificant degradation of TVR in women by (1.2-3.6%), adults ≥70 years (3.7%), younger <40 years (1.9%), HR<60bpm (1.2%), HR>90bpm (3.9%), no degradation for HR change (0 to >20bpm).

  20. Comparison of upright LBPP and supine LBNP in terms of cardiovascular and biomechanical parameters to simulate 1/6-G (lunar gravity) and 3/8-G (Martian gravity) activities

    NASA Astrophysics Data System (ADS)

    Schlabs, Thomas; Rosales-Velderrain, Armando; Ruckstuhl, Heidi; Richardson, Sara E.; Hargens, Alan

    Background: Missions of astronauts to Moon and Mars may be planned in the future. From over 40 years of manned spaceflight it is known that the human body experiences cardiovascular and musculoskeletal losses and a decrease in aerobic fitness while exposed to reduced gravity. Because future missions will be much longer than before, further research is needed to improve Earth-based simulations of reduced gravity. Among others, two methods are capable of simu-lating fractional gravity on Earth: upright Lower Body Positive Pressure (LBPP) and supine Lower Body Negative Pressure (LBNP). No previous study has directly compared these two methods to determine which method is better suited to simulate both the biomechanical and cardiovascular responses of performing activity in lunar (1/6-G) and Martian (3/8-G) gravities. Taken previous studies into account and considering the fact that supine posture is closer to the established 10 head-up-tilt lunar simulation, we hypothesized that exercise performed in supine LBNP better simulates the cardiovascular conditions that occur in lunar and Martian gravities. Methods: 12 healthy normal subjects underwent a protocol consisting of resting and walking (0.25 Froude) with LBNP and LBPP. Each protocol was performed in simulated 1/6-G and 3/8-G. Heart-rate (HR), blood pressure, oxygen consumption (VO2), vertical component of the ground reaction force, comfort of the subject and perceived exertion of the subject (Borg Scale) were assessed. The obtained parameters were compared to predicted values for lunar and Martian gravity conditions in order to determine the method that shows the best level of agreement. Results: There was no difference in gait parameters between LBPP and LBNP simulation of lunar and Martian gravity (cadence: P=0.427, normalized stride length: P=0.373, duty fac-tor: P=0.302, and normalized vertical peak force (P=0.064). Mean blood pressure (P=0.398), comfort (P=0.832) and BORG rating (P=0.186) did not differ between the two methods. How-ever, we found that the heart rate (P=0.022) and VO2 (P=0.038) were significantly higher during LBPP (HRM oon =74±3 bpm, HRM ars =80±3 bpm, VO2M oon =4.6±0.22 l*kg-1 *min-1 , VO2M ars =6.17±0.38 l*kg-1 *min-1 ) than in LBNP (HRM oon =72±3 bpm, HRM ars =77±3 bpm, VO2M oon =4.66±0.43 l*kg-1 *min-1 , VO2M ars =5.66±0.42 l*kg-1 *min-1 ). A further analysis of deviation from the predicted parameters (HRM oon =77 bpm, HRM ars =84 bpm, VO2M oon =5.40 l*kg-1 *min-1 , VO2M ars =7.14 l*kg-1 *min-1 ) revealed a smaller deviation for LBPP (∆HR=4 bpm, ∆VO2=0.89 l*kg-1 *min-1 ) as compared to LBNP (∆HR=6 bpm, ∆VO2=1.11 l*kg-1 *min-1 ). Discussion: We conclude that biomechanical characteristics of gait are not different between supine LBNP and upright LBPP. In terms of cardiovascular parameters there are only differ-ences in heart rate and VO2. The higher heart rate during upright LBPP is probably due to a lower preload of the heart; as venous return is attenuated when the subject is positioned upright instead of supine. The higher VO2 during upright LBPP reflects the increased activity of anti-gravity muscles working to keep the upper body in balance without body suspension. Most skeletal muscles are not used when lying at rest in supine LBNP. Considering that values for heart rate and VO2 produced with the LBPP simulation had a smaller deviation from the predicted values than with the LBNP simulation, we conclude that upright LBPP is obviously better suited to simulate both lunar and Martian activities.

  1. CCD Astrometric Measurements of Double Stars BAL 746, BPM 342, KU 92, and STF 897

    NASA Astrophysics Data System (ADS)

    Smith, Schuyler

    2017-07-01

    Double stars WDS 06589-0106 (BAL 746), WDS 06579+1430 (BPM 342), WDS 07006+0921 (KU 92), and WDS 06224+2640 (STF 897) were measured as part of a science fair project for the 2016 Greater San Diego Science and Engineering Fair. The goal was to measure the separation and position angles of stars by using a telescope with a charge-coupled device (CCD) on the iTelescope network. Five images were taken of each of the stars. These images were plate solved with Visual PinPoint and measured using Aladin Sky Atlas. Measurements for all five doubles compare well to the more recent values in the Washington Double Star Catalog.

  2. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Huang, Xiaobiao

    2016-05-13

    Here, we propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. Finally, the method has been successfully demonstrated on the NSLS-II storage ring.

  3. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Huang, Xiaobiao

    2016-08-01

    We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. Furthermore, the fitting results are used for lattice correction. Our method has been successfully demonstrated on the NSLS-II storage ring.

  4. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Huang, Xiaobiao

    2016-08-01

    We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

  5. Directed Block Copolymer Assembly versus Electron Beam Lithography for Bit-Patterned Media with Areal Density of 1 Terabit/inch(2) and Beyond.

    PubMed

    Yang, Xiaomin; Wan, Lei; Xiao, Shuaigang; Xu, Yuan; Weller, Dieter K

    2009-07-28

    The directed self-assembly of block copolymer (BCP) offers a new route to perfect nanolithographic patterning at sub-50 nm length scale with molecular scale precision. We have explored the feasibility of using the BCP approach versus the conventional electron beam (e-beam) lithography to create highly dense dot patterns for bit-patterned media (BPM) applications. Cylinder-forming poly(styrene-b-methyl methacrylate) (PS-b-PMMA) directly self-assembled on a chemically prepatterned substrate. The nearly perfect hexagonal arrays of perpendicularly oriented cylindrical pores at a density of approximately 1 Terabit per square inch (Tb/in.(2)) are achieved over an arbitrarily large area. Considerable gains in the BCP process are observed relative to the conventional e-beam lithography in terms of the dot size variation, the placement accuracy, the pattern uniformity, and the exposure latitude. The maximum dimensional latitude in the cylinder-forming BCP patterns and the maximum skew angle that the BCP can tolerate have been investigated for the first time. The dimensional latitude restricts the formation of more than one lattice configuration in certain ranges. More defects in BCP patterns are observed when using low molecular weight BCP materials or on non-hexagonal prepatterns due to the dimensional latitude restriction. Finally, the limitations and challenges in the BCP approach that are associated with BPM applications will be briefly discussed.

  6. Impact of electroviscosity on the hydraulic conductance of the bordered pit membrane: a theoretical investigation.

    PubMed

    Santiago, Michael; Pagay, Vinay; Stroock, Abraham D

    2013-10-01

    In perfusion experiments, the hydraulic conductance of stem segments ( ) responds to changes in the properties of the perfusate, such as the ionic strength ( ), pH, and cationic identity. We review the experimental and theoretical work on this phenomenon. We then proceed to explore the hypothesis that electrokinetic effects in the bordered pit membrane (BPM) contribute to this response. In particular, we develop a model based on electroviscosity in which hydraulic conductance of an electrically charged porous membrane varies with the properties of the electrolyte. We use standard electrokinetic theory, coupled with measurements of electrokinetic properties of plant materials from the literature, to determine how the conductance of BPMs, and therefore , may change due to electroviscosity. We predict a nonmonotonic variation of with with a maximum reduction of 18%. We explore how this reduction depends on the characteristics of the sap and features of the BPM, such as pore size, density of chargeable sites, and their dissociation constant. Our predictions are consistent with changes in observed for physiological values of sap and pH. We conclude that electroviscosity is likely responsible, at least partially, for the electrolyte dependence of conductance through pits and that electroviscosity may be strong enough to play an important role in other transport processes in xylem. We conclude by proposing experiments to differentiate the impact of electroviscosity on from that of other proposed mechanisms.

  7. Electro-optical parameters of bond polarizability model for aluminosilicates.

    PubMed

    Smirnov, Konstantin S; Bougeard, Daniel; Tandon, Poonam

    2006-04-06

    Electro-optical parameters (EOPs) of bond polarizability model (BPM) for aluminosilicate structures were derived from quantum-chemical DFT calculations of molecular models. The tensor of molecular polarizability and the derivatives of the tensor with respect to the bond length are well reproduced with the BPM, and the EOPs obtained are in a fair agreement with available experimental data. The parameters derived were found to be transferable to larger molecules. This finding suggests that the procedure used can be applied to systems with partially ionic chemical bonds. The transferability of the parameters to periodic systems was tested in molecular dynamics simulation of the polarized Raman spectra of alpha-quartz. It appeared that the molecular Si-O bond EOPs failed to reproduce the intensity of peaks in the spectra. This limitation is due to large values of the longitudinal components of the bond polarizability and its derivative found in the molecular calculations as compared to those obtained from periodic DFT calculations of crystalline silica polymorphs by Umari et al. (Phys. Rev. B 2001, 63, 094305). It is supposed that the electric field of the solid is responsible for the difference of the parameters. Nevertheless, the EOPs obtained can be used as an initial set of parameters for calculations of polarizability related characteristics of relevant systems in the framework of BPM.

  8. Six Years in the Life of a Mother Bear - The Longest Continuous Heart Rate Recordings from a Free-Ranging Mammal

    NASA Astrophysics Data System (ADS)

    Laske, Timothy G.; Iaizzo, Paul A.; Garshelis, David L.

    2017-01-01

    Physiological monitoring of free-ranging wild animals is providing new insights into their adaptations to a changing environment. American black bears (Ursus americanus) are highly adaptable mammals, spending up to half the year hibernating, and the remainder of the year attempting to gain weight on a landscape with foods that vary seasonally and year to year. We recorded heart rate (HR) and corresponding activity of an adult female black bear over the course of six years, using an implanted monitor. Despite yearly differences in food, and an every-other year reproductive cycle, this bear exhibited remarkable consistency in HR and activity. HR increased for 12 weeks in spring, from minimal hibernation levels (mean 20-25 beats/minute [bpm]; min 10 bpm) to summer active levels (July daytime: mean 95 bpm). Timing was delayed following one cold winter. In August the bear switched from primarily diurnal to nocturnal, coincident with the availability of baits set by legal hunters. Activity in autumn was higher when the bear was with cubs. Birthing of cubs in January was identified by a transient increase in HR and activity. Long-term physiological and behavioral monitoring is valuable for understanding adaptations of free-ranging animals to climate change, food availability, and human-related stressors.

  9. Influences on decision-making for young women undergoing bilateral prophylactic mastectomy.

    PubMed

    Glassey, Rachael; O'Connor, Moira; Ives, Angela; Saunders, Christobel; Hardcastle, Sarah J

    2018-02-01

    The objective of this study was to explore the influences on decision-making of younger women (<35) undergoing or considering bilateral prophylactic mastectomy (BPM). Qualitative interviews guided by interpretative phenomenological analysis (IPA) were conducted with forty-six women who had a strong family history of breast cancer (BC) who had either undergone (n=26) or were considering (n=20) BPM. Participants were recruited from Australia and New Zealand (NZ) via hospitals, a genetics clinic, a research cohort, a registry and online. Four themes underpinning the influences on decision-making were identified: fear and anxiety, children, personal experiences with BC, health professional's influence. The decision to undergo BPM for younger women (<35) was multifaceted, however, it appeared that fear and anxiety were the main influence. Younger women appear more anxious than previous research with older women. There appears to be few differences between those with confirmed BRCA1/2 mutations and those with no known mutation and this is clinically significant. These findings have important practice implications, particularly improving communication of risk statistics, especially to those with no known mutation. Health professionals need to take into account the way younger women perceive information given to them when discussing risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Four factors underlying mouse behavior in an open field

    PubMed Central

    Tanaka, Shoji; Young, Jared W.; Halberstadt, Adam L.; Masten, Virginia L.; Geyer, Mark A.

    2012-01-01

    The observation of the locomotor and exploratory behaviors of rodents in an open field is one of the most fundamental methods used in the field of behavioral pharmacology. A variety of behaviors can be recorded automatically and can readily generate a multivariate pattern of pharmacological effects. Nevertheless, the optimal ways to characterize observed behaviors and concomitant drug effects are still under development. The aim of this study was to extract meaningful behavioral factors that could explain variations in the observed variables from mouse exploration. Behavioral data were recorded from male C57BL/6J mice (n = 268) using the Behavioral Pattern Monitor (BPM). The BPM data were subjected to the exploratory factor analysis. The factor analysis extracted four factors: activity, sequential organization, diversive exploration, and inspective exploration. The activity factor and the two types of exploration factors correlated positively with one another, while the sequential organization factor negatively correlated with the remaining factors. The extracted factor structure constitutes a behavioral model of mouse exploration. This model will provide a platform on which one can assess the effects of psychoactive drugs and genetic manipulations on mouse exploratory behavior. Further studies are currently underway to examine the factor structure of similar multivariate data sets from humans tested in a human BPM. PMID:22569582

  11. Six Years in the Life of a Mother Bear - The Longest Continuous Heart Rate Recordings from a Free-Ranging Mammal.

    PubMed

    Laske, Timothy G; Iaizzo, Paul A; Garshelis, David L

    2017-01-17

    Physiological monitoring of free-ranging wild animals is providing new insights into their adaptations to a changing environment. American black bears (Ursus americanus) are highly adaptable mammals, spending up to half the year hibernating, and the remainder of the year attempting to gain weight on a landscape with foods that vary seasonally and year to year. We recorded heart rate (HR) and corresponding activity of an adult female black bear over the course of six years, using an implanted monitor. Despite yearly differences in food, and an every-other year reproductive cycle, this bear exhibited remarkable consistency in HR and activity. HR increased for 12 weeks in spring, from minimal hibernation levels (mean 20-25 beats/minute [bpm]; min 10 bpm) to summer active levels (July daytime: mean 95 bpm). Timing was delayed following one cold winter. In August the bear switched from primarily diurnal to nocturnal, coincident with the availability of baits set by legal hunters. Activity in autumn was higher when the bear was with cubs. Birthing of cubs in January was identified by a transient increase in HR and activity. Long-term physiological and behavioral monitoring is valuable for understanding adaptations of free-ranging animals to climate change, food availability, and human-related stressors.

  12. Four factors underlying mouse behavior in an open field.

    PubMed

    Tanaka, Shoji; Young, Jared W; Halberstadt, Adam L; Masten, Virginia L; Geyer, Mark A

    2012-07-15

    The observation of the locomotor and exploratory behaviors of rodents in an open field is one of the most fundamental methods used in the field of behavioral pharmacology. A variety of behaviors can be recorded automatically and can readily generate a multivariate pattern of pharmacological effects. Nevertheless, the optimal ways to characterize observed behaviors and concomitant drug effects are still under development. The aim of this study was to extract meaningful behavioral factors that could explain variations in the observed variables from mouse exploration. Behavioral data were recorded from male C57BL/6J mice (n=268) using the Behavioral Pattern Monitor (BPM). The BPM data were subjected to the exploratory factor analysis. The factor analysis extracted four factors: activity, sequential organization, diversive exploration, and inspective exploration. The activity factor and the two types of exploration factors correlated positively with one another, while the sequential organization factor negatively correlated with the remaining factors. The extracted factor structure constitutes a behavioral model of mouse exploration. This model will provide a platform on which one can assess the effects of psychoactive drugs and genetic manipulations on mouse exploratory behavior. Further studies are currently underway to examine the factor structure of similar multivariate data sets from humans tested in a human BPM. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality.

    PubMed

    DeFrance, Tony; Dubois, Eric; Gebow, Dan; Ramirez, Alex; Wolf, Florian; Feuchtner, Gudrun M

    2010-01-01

    Helical prospective ECG-gating (pECG) may reduce radiation dose while maintaining the advantages of helical image acquisition for coronary computed tomography angiography (CCTA). Aim of this study was to evaluate helical pECG-gating in CCTA in regards to radiation dose and image quality. 86 patients undergoing 64-multislice CCTA were enrolled. pECG-gating was performed in patients with regular heart rates (HR) < 65 bpm; with the gating window set at 70-85% of the cardiac cycle. All patients received oral and some received additional IV beta-blockers to achieve HR < 65 bpm. In patients with higher or irregular HR, or for functional evaluation, retrospective ECG-gating (rECG) was performed. The average X-ray dose was estimated from the dose length product. Each arterial segment (modified AHA/ACC 17-segment-model) was evaluated on a 4-point image quality scale (4 = excellent; 3 = good, mild artefact; 2 = acceptable, some artefact, 1 = uninterpretable). pECG-gating was applied in 57 patients, rECG-gating in 29 patients. There was no difference in age, gender, body mass index, scan length or tube output settings between both groups. HR in the pECG-group was 54.7 bpm (range, 43-64). The effective radiation dose was significantly lower for patients scanned with pECG-gating with mean 6.9 mSv +/- 1.9 (range, 2.9-10.7) compared to rECG with 16.9 mSv +/- 4.1 (P < 0.001), resulting in a mean dose reduction of 59.2%. For pECG-gating, out of 969 coronary segments, 99.3% were interpretable. Image quality was excellent in 90.2%, good in 7.8%, acceptable in 1.3% and non-interpretable in 0.7% (n = 7 segments). For patients with steady heart rates <65 bpm, helical prospective ECG-gating can significantly lower the radiation dose while maintaining high image quality.

  14. Physiologic Responses, Liking and Motivation for Playing the Same Video Game on an Active Versus a Traditional, Non-Active Gaming System.

    PubMed

    Sanders, Gabriel J; Santo, Antonio S; Peacock, Corey A; Williamson, Megan L; VON Carlowitz, Kyle-Patrick; Barkley, Jacob E

    Evidence suggests that individuals playing certain video games on the Nintendo Wii® (Wii) exhibit increased energy expenditure versus traditional video games, although little research examines non-Wii Sports/Fit games. The purpose of this study is to assess physiologic responses, liking, and the relative reinforcing value (RRV) of a popular, non-Wii sports video game for the Wii relative to the same game played on a traditional, non-active system. Twenty-four college-aged students participated. Heart rate and oxygen consumption (V̇O 2 ) was assessed during rest and when playing the following games: Madden NFL 2011® for Playstation 2 (PS2 Madden) and the Wii (Wii Madden), and Wii Sports Boxing. The RRV was assessed for Wii Madden versus PS2 Madden. Analysis of variance demonstrated a main effect for condition ( p ≤ 0.01) as V̇O 2 (5.2 ± 0.2 ml·kg -1 ·min -1 Wii, 4.1 ± 0.1 ml·kg -1 ·min -1 PS2, 3.7 ± 0.1 ml·kg -1 ·min -1 , rest) and heart rate (89.2 · 2.7 bpm Wii, 79.7 ± 2.5 bpm PS2, 79.1 ± 2.5 bpm, rest) was greater for Wii Madden than PS2 Madden and rest. Heart Rate (105.4 ± 5.3 bpm) and V̇O 2 (10.4 ml·kg -1 ·min -1 ) for Wii Sports Boxing was significantly greater than all other conditions ( p ≤ 0.003). The RRV was not significantly different between Wii Madden and PS2 Madden ( p = 0.50). Compared to the same game on a traditional system, Wii Madden is more physiologically challenging and equally reinforcing. However, Wii Madden would not be categorized as moderate-intensity physical activity.

  15. Physiologic Responses, Liking and Motivation for Playing the Same Video Game on an Active Versus a Traditional, Non-Active Gaming System

    PubMed Central

    SANDERS, GABRIEL J.; SANTO, ANTONIO S.; PEACOCK, COREY A.; WILLIAMSON, MEGAN L.; VON CARLOWITZ, KYLE-PATRICK; BARKLEY, JACOB E.

    2012-01-01

    Evidence suggests that individuals playing certain video games on the Nintendo Wii® (Wii) exhibit increased energy expenditure versus traditional video games, although little research examines non-Wii Sports/Fit games. The purpose of this study is to assess physiologic responses, liking, and the relative reinforcing value (RRV) of a popular, non-Wii sports video game for the Wii relative to the same game played on a traditional, non-active system. Twenty-four college-aged students participated. Heart rate and oxygen consumption (V̇O2) was assessed during rest and when playing the following games: Madden NFL 2011® for Playstation 2 (PS2 Madden) and the Wii (Wii Madden), and Wii Sports Boxing. The RRV was assessed for Wii Madden versus PS2 Madden. Analysis of variance demonstrated a main effect for condition (p ≤ 0.01) as V̇O2 (5.2 ± 0.2 ml·kg−1·min−1 Wii, 4.1 ± 0.1 ml·kg−1·min−1 PS2, 3.7 ± 0.1 ml·kg−1·min−1, rest) and heart rate (89.2 · 2.7 bpm Wii, 79.7 ± 2.5 bpm PS2, 79.1 ± 2.5 bpm, rest) was greater for Wii Madden than PS2 Madden and rest. Heart Rate (105.4 ± 5.3 bpm) and V̇O2 (10.4 ml·kg−1·min−1) for Wii Sports Boxing was significantly greater than all other conditions (p ≤ 0.003). The RRV was not significantly different between Wii Madden and PS2 Madden (p = 0.50). Compared to the same game on a traditional system, Wii Madden is more physiologically challenging and equally reinforcing. However, Wii Madden would not be categorized as moderate-intensity physical activity. PMID:27182381

  16. A novel modality for intrapartum fetal heart rate monitoring.

    PubMed

    Ashwal, Eran; Shinar, Shiri; Aviram, Amir; Orbach, Sharon; Yogev, Yariv; Hiersch, Liran

    2017-11-02

    Intrapartum fetal heart rate (FHR) monitoring is well recommended during labor to assess fetal wellbeing. Though commonly used, the external Doppler and fetal scalp electrode monitor have significant shortcomings. Lately, non-invasive technologies were developed as possible alternatives. The objective of this study is to compare the accuracy of FHR trace using novel Electronic Uterine Monitoring (EUM) to that of external Doppler and fetal scalp electrode monitor. A comparative study conducted in a single tertiary medical center. Intrapartum FHR trace was recorded simultaneously using three different methods: internal fetal scalp electrode, external Doppler, and EUM. The latter, a multichannel electromyogram (EMG) device acquires a uterine signal and maternal and fetal electrocardiograms. FHR traces obtained from all devices during the first and second stages of labor were analyzed. Positive percent of agreement (PPA) and accuracy (by measuring root means square error between observed and predicted values) of EUM and external Doppler were both compared to internal scalp electrode monitoring. A Bland-Altman agreement plot was used to compare the differences in FHR trace between all modalities. For momentary recordings of fetal heart rate <110 bpm or >160 bpm level of agreement, sensitivity, and specificity were also evaluated. Overall, 712,800 FHR momentary recordings were obtained from 33 parturients. Although both EUM and external Doppler highly correlated with internal scalp electrode monitoring (r 2  = 0.98, p < .001 for both methods), the accuracy of EUM was significantly higher than external Doppler (99.0% versus 96.6%, p < .001). In addition, for fetal heart rate <110 bpm or >160 bpm, the PPA, sensitivity, and specificity of EUM as compared with internal fetal scalp electrode, were significantly greater than those of external Doppler (p < .001). Intrapartum FHR using EUM is both valid and accurate, yielding higher correlations with internal scalp electrode monitoring than external Doppler. As such, it may provide a good framework for non-invasive evaluation of intrapartum FHR.

  17. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability.

    PubMed

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics

  18. Physical Demands of Women's Rugby Sevens Matches: Female Athletes in Motion (FAiM) Study.

    PubMed

    Vescovi, J D; Goodale, T

    2015-11-01

    This cross-sectional study characterized the locomotor, heart rate and metabolic power characteristics of women's rugby sevens matches. 4 Canadian teams were monitored during the USA Rugby Sevens event using global positioning system technology with players classified as International (n=16) or Developmental (n=13). Dependent variables were compared between these 2 groups using an ANOVA with duration played as a covariate. International players covered greater distances (1 468±88 m) than Developmental (1 252±135 m); mostly from more high-intensity (224±55 m vs. 131±44 m) and sprint distances (128±67 m vs. 57±44 m). International players also had more distance in high (264±36 m vs. 210±54 m), elevated (118±17 m vs. 76±20 m) and maximal (69±17 m vs. 30 ± 15 m) metabolic power categories. Time in various heart rate zones was similar between standards; however peak (187±6 bpm vs. 194±5 bpm) and mean (172±7 bpm vs. 180±9 bpm) heart rate values were lower for International players. International players had greater fitness scores (YoYo IRT1-1 160±191 m vs. 781±129 m) and maximal sprint speed (27.3±0.7 vs. 26.0±1.5 km·h(-1)). The current findings highlight developmental gaps in match demands between standards and show that field-based fitness tests discriminate among levels of play. The external and internal loads should be used by sport organizations to assist in forming appropriate training plans and utilize the performance tests to help monitor player development. © Georg Thieme Verlag KG Stuttgart · New York.

  19. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability

    NASA Astrophysics Data System (ADS)

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.

  20. Acute Autonomic Engagement Assessed by Heart Rate Dynamics During Vagus Nerve Stimulation in Patients With Heart Failure in the ANTHEM-HF Trial.

    PubMed

    Nearing, Bruce D; Libbus, Imad; Amurthur, Badri; Kenknight, Bruce H; Verrier, Richard L

    2016-09-01

    Chronic vagus nerve stimulation (VNS) applied to produce biomimetic levels of parasympathetic activation is feasible, well tolerated, safe, improves left ventricular ejection fraction, NYHA class, heart rate variability, and baroreflex function, and reduces T-wave alternans (TWA) in patients with chronic heart failure. However, the acute effects of VNS on beat-to-beat heart rate dynamics have not been systematically characterized in humans. We evaluated acute effects of VNS on R-R-interval dynamics during the VNS titration period in patients (n = 59) enrolled in ANTHEM-HF trial by quantifying effects during continuous cyclic VNS (14-seconds on-time, 66-seconds off-time) adjusted to the maximum tolerable dose without excessive (<4 bpm) bradycardia during the 10-week titration period. VNS elicited an immediate change in heart rate that was correlated to VNS current amplitude, pulse width, and frequency. Heart rate decreased more in the 28 patients with right-sided stimulation (-2.22 ± 0.13 bpm) than in the 31 patients with left-sided stimulation (-0.60 ± 0.08 bpm, P < 0.001). The linear correlation between stimulus intensity and lengthening of the R-R interval was stronger among the 28 patients with right-sided VNS implantation (r = 0.88, P < 0.0001) than among the 31 patients with left-sided VNS implantation (r = 0.49, P < 0.002). In all patients, the heart rate change elicited by VNS was significantly greater than the change during the same timing intervals in 10 randomly selected patients without stimulation (+0.08 ± 0.06 bpm, P < 0.001). Instantaneous heart rate change during therapeutic levels of VNS in patients with heart failure indicates consistent modulation of the autonomic nervous system for both left- and right-sided stimulation. © 2016 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.

  1. Age-Predicted Maximal Heart Rate in Recreational Marathon Runners: A Cross-Sectional Study on Fox's and Tanaka's Equations

    PubMed Central

    Nikolaidis, Pantelis T.; Rosemann, Thomas; Knechtle, Beat

    2018-01-01

    Age-based prediction equations of maximal heart rate (HRmax), such as the popular formulas Fox's 220-age, or Tanaka's 208-0.7 × age, have been widely used in various populations. Surprisingly, so far these equations have not been validated in marathon runners, despite the importance of the role of HRmax for training purposes in endurance running. The aim of the present study was to examine the validity of Fox and Tanaka equations in a large sample of women and men recreational marathon runners. Participants (n = 180, age 43.2 ± 8.5 years, VO2max 46.8 mL/min/kg, finishers in at least one marathon during the last year) performed a graded exercise test on a treadmill, where HRmax was measured. Measured HRmax correlated largely with age in the total sample (r = −0.50, p < 0.001), women (r = −0.60, p < 0.001) and men (r = −0.53, p < 0.001). In women, a large main effect of method on HRmax (p = 0.001, η2 = 0.294) was shown with measured HRmax lower than Fox-HRmax (−4.8 bpm; −8.4, −1.3) and Tanaka-HRmax (−4.9 bpm; −8.1, −1.8). In men, a moderate effect of assessment method on HRmax was found (p = 0.001, η2 = 0.066) with measured HRmax higher than Fox-HRmax (+2.8; 1.0, 4.6), Tanaka-HRmax higher than Fox-HRmax (+1.2; 0.7, 1.7). Based on these findings, it was concluded that Fox and Tanaka' formulas overestimated HRmax by ~5 bpm in women, whereas Fox underestimated HRmax in men by ~3 bpm. Thus, we recommend the further use of Tanaka's formula in men marathon runners. In addition, exercise physiologists and sport scientists should consider the observed differences among various assessment methods when performing exercise testing or prescribing training program relying on HR. PMID:29599724

  2. Cardiorespiratory Improvements Achieved by American College of Sports Medicine’s Exercise Prescription Implemented on a Mobile App

    PubMed Central

    Rospo, Gianluca; Valsecchi, Viola; Bonomi, Alberto G; Thomassen, Inge WJ; van Dantzig, Saskia; La Torre, Antonio

    2016-01-01

    Background Strong evidence shows that an increase in cardiorespiratory fitness (CRF) and physical activity (PA) reduces cardiovascular disease risk. Objective To test whether a scientifically endorsed program to increase CRF and PA, implemented on an easy-to-use, always-accessible mobile app would be effective in improving CRF. Methods Of 63 healthy volunteers participating, 18 tested the user interface of the Cardio-Fitness App (CF-App); and 45 underwent a 2-week intervention period, of whom 33 eventually concluded it. These were assigned into three groups. The Step-based App (Step-App) group (n=8), followed 10,000 steps/day prescription, the CF-App group (n=13), and the Supervised Cardio-Fitness (Super-CF) group (n=12), both followed a heart rate (HR)-based program according to American College of Sports Medicine (ACSM) guidelines, but either implemented on the app, or at the gym, respectively. Participants were tested for CRF, PA, resting systolic and diastolic blood pressures (SBP, DBP), resting, exercise, and recovery HR. Results CRF increased in all groups (+4.9%; P<.001). SBP decreased in all groups (-2.6 mm Hg; P=.03). DBP decrease was higher in the Super-CF group (-3.5 mm Hg) than in the Step-App group (-2.1 mm Hg; P<.001). Posttest exercise HR decreased in all groups (-3.4 bpm; P=.02). Posttest recovery HR was lower in the Super-CF group (-10.1 bpm) than in the other two groups (CF-App: -4.9 bpm, Step-App: -3.3 bpm; P<.001). The CF-App group, however, achieved these improvements with more training heart beats (P<.01). Conclusions A 10,000 steps/day target-based app improved CRF similar to an ACSM guideline-based program whether it was implemented on a mobile app or in supervised gym sessions. PMID:27339153

  3. Cugini's syndrome in statu nascendi. Oratio contra morem prevalentem et pro chronobiologica ratione ad pressione sanguinis curandam. A plea against the prevailing custom and in favor of a chronobiological approach to treating blood pressure.

    PubMed

    Cornélissen, G; Halberg, F; Beaty, L; Kumagai, Y; Halberg, E; Halberg, J; Lee, J; Schwartzkopff, O; Otsuka, K

    2009-01-01

    An increase in the circadian amplitude (A) of blood pressure (BP) had been reported to precede a rise in the circadian BP average (MESOR, M), as pre-hypertension in the stroke-prone Okamoto rat. In humans, children with a positive family history of high BP and/or related cardiovascular disease had, on average, a larger BP-A than children with a negative family history, and an elevated BP-A was associated with intermediate values of the left ventricular mass index (LVMI), whereas an elevation in BP-M was only observed for larger LVMI values. Against this background, with 24-hour ambulatory monitoring (ABPM) interpreted chronobiologically, Pietro Cugini (University La Sapienza of Rome, Italy) has reported an elevation of both the circadian BP-M and BP-A as occurring with a minimal change (hypertensive) retinopathy. He determined by cosinor the extent of predictable BP change within a day as BP-2A, estimated by the least squares fit of a 24-hour cosine curve to the data. As compared to controls without retinopathy, he found a retinal end-organ involvement associated with average systolic (S) / diastolic (D) BP-Ms of 124/76 vs. 112/72 mmHg, with corresponding SBP/DBP-As of 12/10 vs. 8/7 mmHg. We refer to "Cugini's syndrome", suggesting the need for clarification, preferably in longitudinal studies, of any generalizable sequence in end-organ involvement, that may occur in the course of the development of some human Vascular Variability Disorders (VVDs) of unknown etiology, that include an elevation of the circadian BP-A and/or BP-M, concomitantly or separately in a sequence with the BP-A increase preceding that in BP-M, as in models of high BP in the rat or vice versa. Seven-day half-hourly or hourly around-the-clock monitoring of BP and HR variability interpreted chronobiologically, C-ABPM, as a minimum, is recommended for routine medical care to detect VVDs consisting of 1. MESOR-hypertension, MH; 2. Circadian Hyper-Amplitude-Tension, CHAT (BP overswing); 3. odd timing of the circadian rhythm of BP but not that of HR; 4. above-threshold pulse pressure; and/or 5. below-threshold HR variability. All conditions are best determined by 24-hour/7-day or, when abnormality is detected, longer C-ABPM. Eventually, all conditions will need to be assessed in the light of reference values from gender- and age-matched peers, as is now the case for the fi rst three VVDs listed above. When C-ABPM is not practicable, a 7-day series of 3-hourly manual self-measurements during waking (and one measurement about mid-sleep) (C-MBPM) is recommended. When continuous monitoring becomes possible, as it is within the state of the science, detecting Cugini's syndrome will also become possible with the clarification as to whether any change in BP-M and/or BP-A occurs concomitantly or sequentially, with changes in BP-A anticipated to precede changes in BP-M.

  4. Noninterceptive transverse emittance measurements using BPM for Chinese ADS R&D project

    NASA Astrophysics Data System (ADS)

    Wang, Zhi-Jun; Feng, Chi; He, Yuan; Dou, Weiping; Tao, Yue; Chen, Wei-long; Jia, Huan; Liu, Shu-hui; Wang, Wang-sheng; Zhang, Yong; Wu, Jian-qiang; Zhang, Sheng-hu; Zhang, X. L.

    2016-04-01

    The noninterceptive four-dimensional transverse emittance measurements are essential for commissioning the high power continue-wave (CW) proton linacs as well as their operations. The conventional emittance measuring devices such as slits and wire scanners are not well suited under these conditions due to sure beam damages. Therefore, the method of using noninterceptive Beam Position Monitor (BPM) is developed and demonstrated on Injector Scheme II at the Chinese Accelerator Driven Sub-critical System (China-ADS) proofing facility inside Institute of Modern Physics (IMP) [1]. The results of measurements are in good agreements with wire scanners and slits at low duty-factor pulsed (LDFP) beam. In this paper, the detailed experiment designs, data analysis and result benchmarking are presented.

  5. Comparative Study of button BPM Trapped Mode Heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Singh, O.

    2009-05-04

    The combination of short bunches and high currents found in modern light sources and colliders can result in the deposition of tens of watts of power in BPM buttons. The resulting thermal distortion is potentially problematic for maintaining high precision beam position stability, and in the extreme case can result in mechanical damage. We present a simple algorithm that uses the input parameters of beam current, bunch length, button diameter, beampipe aperture, and fill pattern to calculate a relative figure-of-merit for button heating. Data for many of the world's light sources and colliders is compiled in a table. Using themore » algorithm, the table is sorted in order of the relative magnitude of button heating.« less

  6. RHIC BPM system average orbit calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff,R.; Cerniglia, P.; Degen, C.

    2009-05-04

    RHIC beam position monitor (BPM) system average orbit was originally calculated by averaging positions of 10000 consecutive turns for a single selected bunch. Known perturbations in RHIC particle trajectories, with multiple frequencies around 10 Hz, contribute to observed average orbit fluctuations. In 2006, the number of turns for average orbit calculations was made programmable; this was used to explore averaging over single periods near 10 Hz. Although this has provided an average orbit signal quality improvement, an average over many periods would further improve the accuracy of the measured closed orbit. A new continuous average orbit calculation was developed justmore » prior to the 2009 RHIC run and was made operational in March 2009. This paper discusses the new algorithm and performance with beam.« less

  7. Wide-angle full-vector beam propagation method based on an alternating direction implicit preconditioner

    NASA Astrophysics Data System (ADS)

    Chui, Siu Lit; Lu, Ya Yan

    2004-03-01

    Wide-angle full-vector beam propagation methods (BPMs) for three-dimensional wave-guiding structures can be derived on the basis of rational approximants of a square root operator or its exponential (i.e., the one-way propagator). While the less accurate BPM based on the slowly varying envelope approximation can be efficiently solved by the alternating direction implicit (ADI) method, the wide-angle variants involve linear systems that are more difficult to handle. We present an efficient solver for these linear systems that is based on a Krylov subspace method with an ADI preconditioner. The resulting wide-angle full-vector BPM is used to simulate the propagation of wave fields in a Y branch and a taper.

  8. Wide-angle full-vector beam propagation method based on an alternating direction implicit preconditioner.

    PubMed

    Chui, Siu Lit; Lu, Ya Yan

    2004-03-01

    Wide-angle full-vector beam propagation methods (BPMs) for three-dimensional wave-guiding structures can be derived on the basis of rational approximants of a square root operator or its exponential (i.e., the one-way propagator). While the less accurate BPM based on the slowly varying envelope approximation can be efficiently solved by the alternating direction implicit (ADI) method, the wide-angle variants involve linear systems that are more difficult to handle. We present an efficient solver for these linear systems that is based on a Krylov subspace method with an ADI preconditioner. The resulting wide-angle full-vector BPM is used to simulate the propagation of wave fields in a Y branch and a taper.

  9. Congenital bronchopulmonary malformation: CT histopathological correlation.

    PubMed

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  10. Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room.

    PubMed

    Kamlin, C Omar F; Dawson, Jennifer A; O'Donnell, Colm P F; Morley, Colin J; Donath, Susan M; Sekhon, Jasbir; Davis, Peter G

    2008-06-01

    To determine the accuracy of heart rate obtained by pulse oximetry (HR(PO)) relative to HR obtained by 3-lead electrocardiography (HR(ECG)) in newborn infants in the delivery room. Immediately after birth, a preductal PO sensor and ECG leads were applied. PO and ECG monitor displays were recorded by a video camera. Two investigators reviewed the videos. Every two seconds, 1 of the investigators recorded HR(PO) and indicators of signal quality from the oximeter while masked to ECG, whereas the other recorded HR(ECG) and ECG signal quality while masked to PO. HR(PO) and HR(ECG) measurements were compared using Bland-Altman analysis. We attended 92 deliveries; 37 infants were excluded due to equipment malfunction. The 55 infants studied had a mean (+/-standard deviation [SD]) gestational age of 35 (+/-3.7) weeks, and birth weight 2399 (+/-869) g. In total, we analyzed 5877 data pairs. The mean difference (+/-2 SD) between HR(ECG) and HR(PO) was -2 (+/-26) beats per minute (bpm) overall and -0.5 (+/-16) bpm in those infants who received positive-pressure ventilation and/or cardiac massage. The sensitivity and specificity of PO for detecting HR(ECG) <100 bpm was 89% and 99%, respectively. PO provided an accurate display of newborn infants' HR in the delivery room, including those infants receiving advanced resuscitation.

  11. Changes in Physiologic Parameters and Effects of Hooding in Red-tailed Hawks ( Buteo jamaicensis ) During Manual Restraint.

    PubMed

    Doss, Grayson A; Mans, Christoph

    2016-06-01

    Manual restraint in birds of prey is required for many veterinary and research procedures. To investigate the effects of handling stress on physiologic parameters in raptorial birds, 8 red-tailed hawks ( Buteo jamaicensis ) were manually restrained over a 15-minute period. Respiratory rate (RR), heart rate (HR), and cloacal temperature were monitored over time and recorded at defined intervals during the experiment. The effect of hooding on physiologic variables was also evaluated in a complete crossover design. Both RR and HR decreased significantly during the 15-minute restraint period (HR, -80 ± 101.4 beats/min [bpm], [P < .01]; RR, -17.5 ± 22.6 breaths/min, [P < .05]). Hooded birds had significantly lower HRs and RRs at 15 minutes of restraint (HR: 232.5 ± 26 bpm, [P < .037]; RR: 33.1 ± 6.7 breaths/min, [P < .05]) compared to birds restrained without a hood (HR: 280 ± 74.1 bpm; RR: 51.5 ± 28.8 breaths/min). Cloacal temperature increased significantly in all manually restrained birds (+2.2 ± 0.7°C, [P < .01]), with a comparable increase in hooded and nonhooded birds. In this study of the effects of manual restraint on red-tailed hawks, hooding versus nonhooding amplified the decrease in HR and RR but had no effect on stress-induced hyperthermia.

  12. Advanced diagnosis of the temporal characteristics of ultra-short electron beams

    NASA Astrophysics Data System (ADS)

    Otake, Yuji

    2011-05-01

    Monitoring the temporal structure of an ultra-short electron beam is an indispensable function in order to tune a machine to obtain a highly qualified beam for a recent sophisticated accelerator, such as an X-ray free electron laser (XFEL), and to maintain stable X-ray laser operation. For this purpose, various instruments, such as an HEM11-mode RF beam deflector (RFDEF), a screen monitor (SCM), an electro-optic (EO) sampling method that uses a ZnTe crystal, and a beam position monitor (BPM) have been developed. The SCM that is used to observe the deflected beam image has a position resolution of 2.5 μm, which corresponds to a temporal resolution of 0.5 fs and it is installed at a position 5 m downstream from the RFDEF. The EO sampling method showed the ability to observe an electron bunch length for up to 300 fs (FWHM) at the SCSS test accelerator. The phase reference cavity of the BPM has an additional function of providing beam arrival timing information. A test for the BPM showed temporal fluctuation of 46 fs on the beam arrival timing at the test accelerator. These monitors with high temporal resolutions allow us to achieve the fine beam tuning demanded for the XFEL. The above-mentioned activities are described in this paper as a review article.

  13. Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion.

    PubMed

    Lee, Jihyoung; Matsumura, Kenta; Yamakoshi, Ken-ichi; Rolfe, Peter; Tanaka, Shinobu; Yamakoshi, Takehiro

    2013-01-01

    Reflection photoplethysmography (PPG) using 530 nm (green) wavelength light has the potential to be a superior method for monitoring heart rate (HR) during normal daily life due to its relative freedom from artifacts. However, little is known about the accuracy of pulse rate (PR) measured by 530 nm light PPG during motion. Therefore, we compared the HR measured by electrocadiography (ECG) as a reference with PR measured by 530, 645 (red), and 470 nm (blue) wavelength light PPG during baseline and while performing hand waving in 12 participants. In addition, we examined the change of signal-to-noise ratio (SNR) by motion for each of the three wavelengths used for the PPG. The results showed that the limit of agreement in Bland-Altman plots between the HR measured by ECG and PR measured by 530 nm light PPG (±0.61 bpm) was smaller than that achieved when using 645 and 470 nm light PPG (±3.20 bpm and ±2.23 bpm, respectively). The ΔSNR (the difference between baseline and task values) of 530 and 470nm light PPG was significantly smaller than ΔSNR for red light PPG. In conclusion, 530 nm light PPG could be a more suitable method than 645 and 470nm light PPG for monitoring HR in normal daily life.

  14. Evidence for a medial prefrontal cortex-hippocampal axis associated with heart rate control in conscious humans.

    PubMed

    Norton, Katelyn N; Luchyshyn, Torri A; Kevin Shoemaker, J

    2013-11-13

    Cardiovascular arousal correlates to activity within the medial prefrontal cortex (MPFC). Additional evidence provides anatomical and functional links between the MPFC and hippocampus (HC). This study tested the hypothesis that the MPFC and HC form a sub-network associated with rapid heart rate (HR) responses to volitional effort. Primary analyses were performed on 29 individuals (18 males) ranging from 21 to 80 years of age, who produced a HR response >3bpm to an isometric handgrip (IHG) task. HR and cortical activity were recorded using functional magnetic resonance imaging with blood oxygen level-dependent contrast. The average change in HR from baseline was 6bpm ±2. Activity in the MPFC and left HC was reduced relative to baseline in all subjects when correlated with the HR time course. Measures of connectivity demonstrated that the MPFC engaged in significantly stronger functional connectivity to the left HC during a 40% IHG task. Effective connectivity revealed a directionality of influence from the MPFC to the left HC. A second group (n=15) of individuals without a HR response (~1bpm) to IHG were studied post-hoc and these individuals showed no deactivation in either the MPFC or left HC. These results suggest the presence of a MPFC-HC axis that participates in the neurally-mediated HR response to exercise. © 2013 Published by Elsevier B.V.

  15. Cellular responses of bioabsorbable polymeric material and Guglielmi detachable coil in experimental aneurysms.

    PubMed

    Murayama, Yuichi; Viñuela, Fernando; Tateshima, Satoshi; Gonzalez, Nestor R; Song, Joon K; Mahdavieh, Haleh; Iruela-Arispe, Luisa

    2002-04-01

    Acceleration of healing mechanisms is a promising approach to improve current limitations of endovascular aneurysm therapy with the use of platinum coils. We evaluated a new endovascular therapeutic, bioabsorbable polymeric material (BPM), which may promote cellular reaction in the aneurysms. Four different concentrations of lactide/glycolic acid copolymer [poly(D-L-lactic-co-glycolic acid)] (PLGA), 85/15, 75/25, 65/35, and 50/50, were used as BPMs. Sixteen experimental aneurysms were created in 8 swine. Eight-millimeter-long spiral-shaped BPMs were surgically implanted in the aneurysms without tight packing (n=3 for each BPM). Guglielmi detachable coils (GDCs) were used as control (n=4). The animals were killed 14 days after embolization, and angiographic, histological, and immunohistochemical analyses were performed. Despite loose packing of aneurysms with BPMs, faster BPMs such as 50/50 or 65/35 PLGA demonstrated more mature collagen formation and fibrosis in the sac and neck of the aneurysm. One aneurysm treated with 65/35 PLGA, 1 treated with 75/25 PLGA, and all 3 treated with 85/15 PLGA showed a neck remnant on angiography. There was a linear relationship between collagen levels and polymer degradation properties (r=-0.9513). This preliminary animal study indicates that acceleration of aneurysm healing with the use of BPM is feasible. This concept can be applied to decrease and perhaps prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.

  16. Monitoring the wild black bear's reaction to human and environmental stressors

    PubMed Central

    2011-01-01

    Background Bears are among the most physiologically remarkable mammals. They spend half their life in an active state and the other half in a state of dormancy without food or water, and without urinating, defecating, or physical activity, yet can rouse and defend themselves when disturbed. Although important data have been obtained in both captive and wild bears, long-term physiological monitoring of bears has not been possible until the recent advancement of implantable devices. Results Insertable cardiac monitors that were developed for use in human heart patients (Reveal® XT, Medtronic, Inc) were implanted in 15 hibernating bears. Data were recovered from 8, including 2 that were legally shot by hunters. Devices recorded low heart rates (pauses of over 14 seconds) and low respiration rates (1.5 breaths/min) during hibernation, dramatic respiratory sinus arrhythmias in the fall and winter months, and elevated heart rates in summer (up to 214 beats/min (bpm)) and during interactions with hunters (exceeding 250 bpm). The devices documented the first and last day of denning, a period of quiescence in two parturient females after birthing, and extraordinary variation in the amount of activity/day, ranging from 0 (winter) to 1084 minutes (summer). Data showed a transition toward greater nocturnal activity in the fall, preceding hibernation. The data-loggers also provided evidence of the physiological and behavioral responses of bears to our den visits to retrieve the data. Conclusions Annual variations in heart rate and activity have been documented for the first time in wild black bears. This technique has broad applications to wildlife management and physiological research, enabling the impact of environmental stressors from humans, changing seasons, climate change, social interactions and predation to be directly monitored over multiple years. PMID:21849079

  17. [Non operative treatment for perforated peptic ulcer: results of a prospective study].

    PubMed

    Songne, B; Jean, F; Foulatier, O; Khalil, H; Scotté, M

    2004-12-01

    The conservative management of perforated peptic ulcer has not gained widespread acceptance despite introduction of proton-pomp inhibitors because surgical procedures can achieve immediate closure by eventually using a laparoscopic approach. The aim of this prospective study was to evaluate the results of Taylor's method and to identify predictive factors of failure of medical treatment in patients presenting with perforated peptic ulcer. Between 1990 and 2000, 82 consecutive patients, with diagnosis of perforated peptic ulcer were prospectively included in this study. They were initially treated with non-operative procedure (nasogastric suction and intravenous administration of H2-blockers or proton-pomp inhibitors). No clinical improvement after 24 hours required a surgical treatment. Predictive factors of failure of non-operative treatment were tested in univariate or multivariate analysis. Clinical improvement was obtained with non-operative treatment in 54% of the patients (44/82). The overall mortality rate was 1%. In univariate analysis, significant predictive factors of failure of non-operative treatment were: size of pneumoperitoneum, heart beat >94 bpm, abdominal meteorism, pain at digital rectal exam, and age >59 years. In multivariate analysis, the significant factors were the size of pneumoperitoneum, heart beat, and abdominal meteorism. The association of these criteria: size of pneumoperitoneum >size of the first lumbar vertebra, heart beat >94 bpm, pain at digital rectal exam and age > 59 years , led to surgical treatment in all cases. These results suggest that more than 50% of patients with perforated peptic ulcer respond to conservative treatment without surgery and that the association of few criteria (size of pneumoperitoneum, heart beat, pain at digital rectal exam and age) require emergency surgery.

  18. Beam property measurement of a 300-kV ion source test stand for a 1-MV electrostatic accelerator

    NASA Astrophysics Data System (ADS)

    Park, Sae-Hoon; Kim, Dae-Il; Kim, Yu-Seok

    2016-09-01

    The KOMAC (Korea Multi-purpose Accelerator Complex) has been developing a 300-kV ion source test stand for a 1-MV electrostatic accelerator for industrial purposes. A RF ion source was operated at 200 MHz with its matching circuit. The beam profile and emittance were measured behind an accelerating column to confirm the beam property from the RF ion source. The beam profile was measured at the end of the accelerating tube and at the beam dump by using a beam profile monitor (BPM) and wire scanner. An Allison-type emittance scanner was installed behind the beam profile monitor (BPM) to measure the beam density in phase space. The measurement results for the beam profile and emittance are presented in this paper.

  19. A three-dimensional wide-angle BPM for optical waveguide structures.

    PubMed

    Ma, Changbao; Van Keuren, Edward

    2007-01-22

    Algorithms for effective modeling of optical propagation in three- dimensional waveguide structures are critical for the design of photonic devices. We present a three-dimensional (3-D) wide-angle beam propagation method (WA-BPM) using Hoekstra's scheme. A sparse matrix algebraic equation is formed and solved using iterative methods. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation, along with a technique for shifting the simulation window to reduce the dimension of the numerical equation and a threshold technique to further ensure its convergence. These techniques can ensure the implementation of iterative methods for waveguide structures by relaxing the convergence problem, which will further enable us to develop higher-order 3-D WA-BPMs based on Padé approximant operators.

  20. Error Correction for the JLEIC Ion Collider Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei, Guohui; Morozov, Vasiliy; Lin, Fanglei

    2016-05-01

    The sensitivity to misalignment, magnet strength error, and BPM noise is investigated in order to specify design tolerances for the ion collider ring of the Jefferson Lab Electron Ion Collider (JLEIC) project. Those errors, including horizontal, vertical, longitudinal displacement, roll error in transverse plane, strength error of main magnets (dipole, quadrupole, and sextupole), BPM noise, and strength jitter of correctors, cause closed orbit distortion, tune change, beta-beat, coupling, chromaticity problem, etc. These problems generally reduce the dynamic aperture at the Interaction Point (IP). According to real commissioning experiences in other machines, closed orbit correction, tune matching, beta-beat correction, decoupling, andmore » chromaticity correction have been done in the study. Finally, we find that the dynamic aperture at the IP is restored. This paper describes that work.« less

Top