Sample records for process sewer line

  1. Modelling of sedimentation and remobilization in in-line storage sewers for stormwater treatment.

    PubMed

    Frehmann, T; Flores, C; Luekewille, F; Mietzel, T; Spengler, B; Geiger, W F

    2005-01-01

    A special arrangement of combined sewer overflow tanks is the in-line storage sewer with downstream discharge (ISS-down). This layout has the advantage that, besides the sewer system, no other structures are required for stormwater treatment. The verification of the efficiency with respect to the processes of sedimentation and remobilization of sediment within the in-line storage sewer with downstream discharge is carried out in a combination of a field and a pilot plant study. The model study was carried out using a pilot plant model scaled 1:13. The following is intended to present some results of the pilot plant study and the mathematical empirical modelling of the sedimentation and remobilization process.

  2. Remediation of Mercury-Contaminated Storm Sewer Sediments from the West End Mercury Area at the Y-12 National Security Complex in Oak Ridge, Tennessee - 12061

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tremaine, Diana; Douglas, Steven G.

    2012-07-01

    The Y-12 National Security Complex in Oak Ridge, TN has faced an ongoing challenge from mercury entrapped in soils beneath and adjacent to buildings, storm sewers, and process pipelines. Previous actions to reduce the quantity and/or mobilization of mercury-contaminated media have included plugging of building floor drains, cleaning of sediment and sludge from sumps, manholes, drain lines, and storm sewers, lining/relining of storm sewers and replacement of a portion of the storm sewer trunk line, re-routing and removal of process piping, and installation of the Central Mercury Treatment System to capture and treat contaminated sump water. Despite the success ofmore » these actions, mercury flux in the storm sewer out-falls that discharge to Upper East Fork Poplar Creek (UEFPC) continues to pose a threat to long-term water quality. A video camera survey of the storm sewer network revealed several sections of storm sewer that had large cracks, separations, swells, and accumulations of sediment/sludge and debris. The selected remedy was to clean and line the sections of storm sewer pipe that were determined to be primary contributors to the mercury flux in the storm sewer out-falls. The project, referred to as the West End Mercury Area (WEMA) Storm Sewer Remediation Project, included cleaning sediment and debris from over 2,460 meters of storm sewer pipe followed by the installation of nearly 366 meters of cure-in-place pipe (CIPP) liner. One of the greatest challenges to the success of this project was the high cost of disposal associated with the mercury-contaminated sludge and wastewater generated from the storm sewer cleaning process. A contractor designed and operated an on-site wastewater pre-treatment system that successfully reduced mercury levels in 191 cubic meters of sludge to levels that allowed it to be disposed at Nevada Nuclear Security Site (NNSS) disposal cell as a non-hazardous, low-level waste. The system was also effective at pre-treating over 1,514,000 liters of wastewater to levels that met the waste acceptance criteria for the on-site West End [wastewater] Treatment Facility (WETF). This paper describes the storm sewer cleaning and lining process and the methods used to process the mercury-contaminated sludge and wastewater, as well as several 'lessons learned' that would be relevant to any future projects involving storm sewer cleaning and debris remediation. (authors)« less

  3. Evidence of a sewer vapor transport pathway at the USEPA ...

    EPA Pesticide Factsheets

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into the duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. These test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope. Highlights • The sewer line is an important pathway for VOC transport at the USEPA duplex. • The importance of this pathway was not identified during prior study of the duplex. • Sewer lines should be routinely evaluated

  4. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex.

    PubMed

    McHugh, Thomas; Beckley, Lila; Sullivan, Terry; Lutes, Chris; Truesdale, Robert; Uppencamp, Rob; Cosky, Brian; Zimmerman, John; Schumacher, Brian

    2017-11-15

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into the duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. These test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    DOE PAGES

    McHugh, Thomas; Beckley, Lila; Sullivan, Terry; ...

    2017-04-26

    We report the role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into themore » duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. Finally, these test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope.« less

  6. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McHugh, Thomas; Beckley, Lila; Sullivan, Terry

    We report the role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into themore » duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. Finally, these test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope.« less

  7. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    EPA Science Inventory

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampl...

  8. 24. The 184B Power House under construction, viewed to the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. The 184-B Power House under construction, viewed to the northeast in March 1944. The sewer line exiting to the Columbia river was used mainly for effluents from back-washing the filter basins. A separate Process Sewer Line (out of the picture to the right) for cooling water leaving the pile went to the 107-B Retention Basin, and ultimately to the river. P-1881 - B Reactor, Richland, Benton County, WA

  9. Flow measurements in sewers based on image analysis: automatic flow velocity algorithm.

    PubMed

    Jeanbourquin, D; Sage, D; Nguyen, L; Schaeli, B; Kayal, S; Barry, D A; Rossi, L

    2011-01-01

    Discharges of combined sewer overflows (CSOs) and stormwater are recognized as an important source of environmental contamination. However, the harsh sewer environment and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. An in situ system for sewer water flow monitoring based on video images was evaluated. Algorithms to determine water velocities were developed based on image-processing techniques. The image-based water velocity algorithm identifies surface features and measures their positions with respect to real world coordinates. A web-based user interface and a three-tier system architecture enable remote configuration of the cameras and the image-processing algorithms in order to calculate automatically flow velocity on-line. Results of investigations conducted in a CSO are presented. The system was found to measure reliably water velocities, thereby providing the means to understand particular hydraulic behaviors.

  10. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    PubMed

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Evaluation of the Effectiveness of Five Odor Reducing Agents for Sewer System Odors Using an On-Line Total Reduced Sulfur Analyzer

    PubMed Central

    Choi, Il; Lee, Hyunjoo; Shin, Joungdu; Kim, Hyunook

    2012-01-01

    Sewer odors have been a concern to citizens of the Metropolitan Seoul region, which has installed combined sewer systems (CSSs) in 86% of its area. Although a variety of odorants are released from sewers, volatile sulfur compounds (VSCs) have been recognized as major ones. A number of technologies have been proposed to monitor or control odors from sewers. One of the most popular strategies adopted for the control of sewage odor is by applying a commercial odor-reducing agent into the sewer. In this study, the effectiveness of five different commercial odor-reducing agents (i.e., an odor masking agent, an alkaline solution, two microbial agents, and a chemical oxidant) was evaluated by continuously monitoring VSCs released from the sewer with an on-line total reduced sulfur (TRS) analyzer before and after each agent was sprayed into CSSs at five different locations of the city. In short, when the effectiveness of odor treatment was tested in the sewer system using five commercial odor reducing treatments, only the chemical oxidant was good enough to reduce the odor in terms of TRS levels measured before and after the application (p < 0.01). PMID:23223148

  12. Demonstration of Innovative Sewer System Inspection Technology SewerBatt

    EPA Science Inventory

    The overall objective of this EPA-funded study was to demonstrate innovative a sewer line assessment technology that is designed for rapid deployment using portable equipment. This study focused on demonstration of a technology that is suitable for smaller diameter pipes (less th...

  13. Sanitary Sewer Systems and Association with Gastrointestinal Illness: A case crossover analysis of Massachusetts Data, 2006-2008

    EPA Science Inventory

    Sanitary sewer overflows (SSOs) occur when untreated sewage is discharged into water sources before reaching the treatment facility potentially contaminating them with gastrointestinal pathogens. Causes of SSOs include heavy rainfall and rupture/blockage of sewer lines. Few studi...

  14. Surface models for coupled modelling of runoff and sewer flow in urban areas.

    PubMed

    Ettrich, N; Steiner, K; Thomas, M; Rothe, R

    2005-01-01

    Traditional methods fail for the purpose of simulating the complete flow process in urban areas as a consequence of heavy rainfall and as required by the European Standard EN-752 since the bi-directional coupling between sewer and surface is not properly handled. The new methodology, developed in the EUREKA-project RisUrSim, solves this problem by carrying out the runoff on the basis of shallow water equations solved on high-resolution surface grids. Exchange nodes between the sewer and the surface, like inlets and manholes, are located in the computational grid and water leaving the sewer in case of surcharge is further distributed on the surface. Dense topographical information is needed to build a model suitable for hydrodynamic runoff calculations; in urban areas, in addition, many line-shaped elements like houses, curbs, etc. guide the runoff of water and require polygonal input. Airborne data collection methods offer a great chance to economically gather densely sampled input data.

  15. Contributions of wastewater, runoff and sewer deposit erosion to wet weather pollutant loads in combined sewer systems.

    PubMed

    Gasperi, J; Gromaire, M C; Kafi, M; Moilleron, R; Chebbo, G

    2010-12-01

    An observatory of urban pollutants was created in Paris for the purpose of assessing the dynamics of wastewater and wet weather flow (WW and WWF) pollutant loads within combined sewers. This observatory is composed of six urban catchments, covering land areas ranging in size from 42 ha to 2581 ha. For a wide array of parameters including total suspended solids (TSS), chemical and biochemical oxygen demand (COD and BOD(5)), total organic carbon (TOC), total Kjeldahl nitrogen (TKN), heavy metals (Cu and Zn) and polycyclic aromatic hydrocarbons (PAHs), this article is intended to evaluate the contributions of wastewater, runoff and in-sewer processes to WWF pollutant loads through the use of an entry-exit mass balance approach. To achieve this objective, a total of 16 rain events were sampled on these sites between May 2003 and February 2006. This study has confirmed that at the considered catchment scale (i.e. from 42 ha to 2581 ha) the production and transfer processes associated with WWF pollutant loads do not vary with basin scale. Entry-exit chemical mass balances over all catchments and for a large number of rain events indicate that wastewater constitutes the main source of organic and nitrogenous pollution, while runoff is the predominant source of Zn. For Cu, PAHs and TSS, the calculation underscores the major role played by in-sewer processes, specifically by sediment erosion, as a source of WWF pollution. A significant loss of dissolved metals was also observed during their transfer within the sewer network, likely as a consequence of the adsorption of dissolved metals on TSS and/or on sewer deposits. Moreover, the nature of eroded particles was examined and compared to the various sewer deposits. This comparison has highlighted that such particles exhibit similar organic and PAH contents to those measured in the organic layer, thus suggesting that the deposit eroded during a wet weather period is organic and of a nature comparable to the organic layer. Despite the extent of initial field investigations, no organic deposit was observed to be present on sewer lines within the catchments, which implies that this organic deposit is probably present in another form or to be found elsewhere in the main trunks. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Greenville, Mississippi Clean Water Settlement

    EPA Pesticide Factsheets

    The City of Greenville, MS (City) owns and operates the Greenville Wastewater Treatment Facility (WWTP), approximately 200 miles of sanitary sewer lines, and 100 sanitary sewer pump stations and associated appurtenances.

  17. Consent Decree for Greenville, Mississippi

    EPA Pesticide Factsheets

    The City of Greenville, MS (City) owns and operates the Greenville Wastewater Treatment Facility (WWTP), approximately 200 miles of sanitary sewer lines, and 100 sanitary sewer pump stations and associated appurtenances.

  18. Predicting concrete corrosion of sewers using artificial neural network.

    PubMed

    Jiang, Guangming; Keller, Jurg; Bond, Philip L; Yuan, Zhiguo

    2016-04-01

    Corrosion is often a major failure mechanism for concrete sewers and under such circumstances the sewer service life is largely determined by the progression of microbially induced concrete corrosion. The modelling of sewer processes has become possible due to the improved understanding of in-sewer transformation. Recent systematic studies about the correlation between the corrosion processes and sewer environment factors should be utilized to improve the prediction capability of service life by sewer models. This paper presents an artificial neural network (ANN)-based approach for modelling the concrete corrosion processes in sewers. The approach included predicting the time for the corrosion to initiate and then predicting the corrosion rate after the initiation period. The ANN model was trained and validated with long-term (4.5 years) corrosion data obtained in laboratory corrosion chambers, and further verified with field measurements in real sewers across Australia. The trained model estimated the corrosion initiation time and corrosion rates very close to those measured in Australian sewers. The ANN model performed better than a multiple regression model also developed on the same dataset. Additionally, the ANN model can serve as a prediction framework for sewer service life, which can be progressively improved and expanded by including corrosion rates measured in different sewer conditions. Furthermore, the proposed methodology holds promise to facilitate the construction of analytical models associated with corrosion processes of concrete sewers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Superfund record of decision (EPA Region 4): Alabama Army Ammunition Plant, Area B soils operable unit, Childersburg, AL, November 14, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    This decision document presents the selected remedial action for the contaminated soils and sediments in Study Areas, 6, 7, and 21, and the Industrial Sewer System (ISS) in Study Areas 6, 7, and 10 within Area B at the Alabama Army Ammunition Plant (ALAAP), Childersburg, Alabama. The Area B Soils Operable Unit addresses the principal threats from soils and sediments in Study Areas 6, 7, and 21, and underground industrial sewer lines in Study Areas 6, 7, and 10. The soils and sediments and the industrial sewer lines are contaminated with explosives and lead.

  20. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines), Waste Site Reclassification Form 2007-028

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. M. Dittmer

    2007-12-03

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  1. Simulation of the wastewater temperature in sewers with TEMPEST.

    PubMed

    Dürrenmatt, David J; Wanner, Oskar

    2008-01-01

    TEMPEST is a new interactive simulation program for the estimation of the wastewater temperature in sewers. Intuitive graphical user interfaces assist the user in managing data, performing calculations and plotting results. The program calculates the dynamics and longitudinal spatial profiles of the wastewater temperature in sewer lines. Interactions between wastewater, sewer air and surrounding soil are modeled in TEMPEST by mass balance equations, rate expressions found in the literature and a new empirical model of the airflow in the sewer. TEMPEST was developed as a tool which can be applied in practice, i.e., it requires as few input data as possible. These data include the upstream wastewater discharge and temperature, geometric and hydraulic parameters of the sewer, material properties of the sewer pipe and surrounding soil, ambient conditions, and estimates of the capacity of openings for air exchange between sewer and environment. Based on a case study it is shown how TEMPEST can be applied to estimate the decrease of the downstream wastewater temperature caused by heat recovery from the sewer. Because the efficiency of nitrification strongly depends on the wastewater temperature, this application is of practical relevance for situations in which the sewer ends at a nitrifying wastewater treatment plant.

  2. Demonstration of Innovative Sewer System Inspection Technology: SL-RAT

    EPA Science Inventory

    The overall objective of this EPA-funded study was to demonstrate innovative sewer line assessment technologies that are designed for rapid deployment using portable equipment. This study focused on demonstration of technologies that are suitable for smaller diameter pipes (less ...

  3. Sulfide and methane production in sewer sediments: Field survey and model evaluation.

    PubMed

    Liu, Yiwen; Tugtas, A Evren; Sharma, Keshab R; Ni, Bing-Jie; Yuan, Zhiguo

    2016-02-01

    Sewer sediment processes have been reported to significantly contribute to overall sulfide and methane production in sewers, at a scale comparable to that of sewer biofilms. The physiochemical and biological characteristics of sewer sediments are heterogeneous; however, the variability of in-sediments sulfide and methane production rates among sewers has not been assessed to date. In this study, five sewer sediment samples were collected from two cities in Australia with different climatic conditions. Batch assays were conducted to determine the rates of sulfate reduction and methane production under different flow velocity (shear stress) conditions as well as under completely mixed conditions. The tests showed substantial and variable sulfate reduction and methane production activities among different sediments. Sulfate reduction and methane production from sewer sediments were confirmed to be areal processes, and were dependent on flow velocity/shear stress. Despite of the varying characteristics and reactions kinetics, the sulfate reduction and methane production processes in all sediments could be well described by a one-dimensional sewer sediment model recently developed based on results obtained from a laboratory sewer sediment reactor. Model simulations indicated that the in-situ contribution of sewer sediment emissions could be estimated without the requirement of measuring the specific sediment characteristics or the sediment depths. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Modelling the viability of heat recovery from combined sewers.

    PubMed

    Abdel-Aal, M; Smits, R; Mohamed, M; De Gussem, K; Schellart, A; Tait, S

    2014-01-01

    Modelling of wastewater temperatures along a sewer pipe using energy balance equations and assuming steady-state conditions was achieved. Modelling error was calculated, by comparing the predicted temperature drop to measured ones in three combined sewers, and was found to have an overall root mean squared error of 0.37 K. Downstream measured wastewater temperature was plotted against modelled values; their line gradients were found to be within the range of 0.9995-1.0012. The ultimate aim of the modelling is to assess the viability of recovering heat from sewer pipes. This is done by evaluating an appropriate location for a heat exchanger within a sewer network that can recover heat without impacting negatively on the downstream wastewater treatment plant (WWTP). Long sewers may prove to be more viable for heat recovery, as heat lost can be reclaimed before wastewater reaching the WWTP.

  5. Effects of sanitary sewers on ground-water levels and streams in Nassau and Suffolk Counties, New York; Part 2, development and application of southwest Suffolk County model

    USGS Publications Warehouse

    Buxton, H.T.; Reilly, T.E.

    1985-01-01

    By 1990, sanitary sewers in Nassau County Sewage Disposal Districts 2 and 3 and Suffolk County Southwest Sewer District will discharge to the ocean 140 cu ft of water/sec that would otherwise be returned to the groundwater system through septic tanks and similar systems. To evaluate the effects of this loss on groundwater levels and streamflow, the U.S. Geological Survey developed a groundwater flow model that couples a fine-scale subregional model to a regional model of larger scale. The regional model generates flux boundary conditions for the subregional model, and the subregional model provides detail in the area of concern. Results indicate that the water table will decline by as much as 8 ft along the Suffolk-Nassau county line, with effects decreasing eastward. Base flow is predicted to decrease by as much as 73% in a stream along the county line, but this effect will decrease to zero just east of the sewered area. This report is one of a series describing the predicted hydrologic effects of sewers in southern Nassau and southwest Suffolk Counties. (USGS)

  6. Finding of No Significant Impact: Proposed Bank Stabilization Tennessee River River Mile 466.2 - 466.5, Hamilton County, Tennessee

    DTIC Science & Technology

    2013-05-02

    Bank erosion is endangering approximately 1,100 feet of a 42-inch concrete gravity sanitary main, two manholes, and a 30-inch iron sanitary sewer...stabilizing the bank. Kingfisher nests are excavated burrows with bare soil along stream banks (USACE, 2009). “Banks with a high content of clay , gravel, or...34’ g -- - -- - - ---- --- -------- 1 LEGEND ESTIMATED 42’’ GRAVITY SEWER LINE ESTIMATED 30’’ FORCE MAIN ® SANITARY SEWER MANHOLE • AUTO

  7. Damage estimation of sewer pipe using subtitles of CCTV inspection video

    NASA Astrophysics Data System (ADS)

    Park, Kitae; Kim, Byeongcheol; Kim, Taeheon; Seo, Dongwoo

    2017-04-01

    Recent frequent occurrence of urban sinkhole serves as a momentum of the periodic inspection of sewer pipelines. Sewer inspection using a CCTV device needs a lot of time and efforts. Many of previous studies which reduce the laborious tasks are mainly interested in the developments of image processing S/W and exploring H/W. And there has been no attempt to find meaningful information from the existing CCTV images stored by the sewer maintenance manager. This study adopts a cross-correlation based image processing method and extracts sewer inspection device's location data from CCTV images. As a result of the analysis of location-time relation, it show strong correlation between device stand time and the sewer damages. In case of using this method to investigate sewer inspection CCTV images, it will save the investigator's efforts and improve sewer maintenance efficiency and reliability.

  8. Bioenvironmental Engineer’s Guide to Indoor Air Quality Surveys

    DTIC Science & Technology

    2014-09-01

    housekeeping practices •Fresh air intake located near contaminant source •Check for sewer line leak, septic tank leak, fuel tank leaks...make-up air •Dirty coils/filters •Sewer gas, drain traps, sanitary vents •Leaky tanks , spills •Cleaning products, pesticides •Poor

  9. Sewers as a source and sink of chlorinated-solvent groundwater contamination, Marine Corps Recruit Depot, Parris Island, South Carolina

    USGS Publications Warehouse

    Vroblesky, D.A.; Petkewich, M.D.; Lowery, M.A.; Landmeyer, J.E.

    2011-01-01

    Groundwater contamination by tetrachloroethene and its dechlorination products is present in two partially intermingled plumes in the surficial aquifer near a former dry-cleaning facility at Site 45, Marine Corps Recruit Depot, Parris Island, South Carolina. The northern plume originates from the vicinity of former above-ground storage tanks. Free-phase tetrachloroethene from activities in this area entered the groundwater. The southern plume originates at a nearby, new dry-cleaning facility, but probably was the result of contamination released to the aquifer from a leaking sanitary sewer line from the former dry-cleaning facility. Discharge of dissolved groundwater contamination is primarily to leaking storm sewers below the water table. The strong influence of sanitary sewers on source distribution and of storm sewers on plume orientation and discharge at this site indicates that groundwater-contamination investigators should consider the potential influence of sewer systems at their sites. ?? 2011, National Ground Water Association.

  10. Assessment of pH shock as a method for controlling sulfide and methane formation in pressure main sewer systems.

    PubMed

    Gutierrez, Oriol; Sudarjanto, Gatut; Ren, Guo; Ganigué, Ramon; Jiang, Guangming; Yuan, Zhiguo

    2014-01-01

    Caustic dosing to raise pH above 10.0 for short periods (hours) is often used by water utilities for controlling sulfide formation in sewers. However the effectiveness of this strategy is rarely reported and the impact of pH level and exposure time on the effectiveness is largely unknown. The effectiveness of this strategy under various pH levels (10.5-12.5) and exposure time (0.5-6.0 h) in controlling sulfide and methane production was evaluated in laboratory scale anaerobic sewer reactors and then in a real sewer system. Laboratory studies showed that the sulfide production rate of the laboratory sewer biofilm was reduced by 70-90% upon the completion of the pH shock, while the methane production rate decreased by 95-100%. It took approximately one week for the sulfate-reducing activity to recover to normal levels. In comparison, the methanogenic activities recovered to only about 10% in 4 weeks. The slow recovery is explained by the substantially loss of cell viability upon pH shocks, which recovered slowly after the shocks. Laboratory studies further revealed that a pH level of 10.5 for 1-2 h represent cost-effective conditions for the pH shock treatment. However, field trials showed a higher pH (11.5) and larger dosing times are needed due to the pH decreases along the sewer line and at the two ends of the caustic-receiving wastewater slugs due to dilution. To have effective sulfide and methane control, it is important to ensure effective conditions (pH > 10.5 and duration >1-2 h) for the entire sewer line. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Use of Bio-Amp, a commercial bio-additive for the treatment of grease trap wastewater containing fat, oil, and grease.

    PubMed

    Tang, Hao L; Xie, Yuefeng F; Chen, Yen-Chih

    2012-11-01

    This research investigated the application of Bio-Amp, a commercial bio-additive for the treatment of fat, oil, and grease (FOG) in a grease trap, and evaluated potential impacts of treated effluent on downstream collection system and treatment processes. Results show that after Bio-Amp treatment, FOG deposit formation was reduced by 40%, implicating a potential reduction of sewer line blockages. Chemical oxygen demand (COD), total nitrogen (TN), total phosphorus (TP) and total fatty acids were reduced by 39%, 33%, 56%, and 59%, respectively, which represents an overall loading reduction of 9% COD, 5% TN and 40% TP received by the treatment plant from all the dining halls. On the other hand, readily biodegradable COD fractions significantly increased, which implies a potential improvement on Bio-P removal. Overall, the results showed that application of Bio-Amp in grease trap provides potential reduction of sewer line blockages, and can also alleviate downstream treatment burden. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. NORTH PORTAL-SANITARY SEWER CALCULATION-SHOP BUILDING #5006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S. Blackstone

    1996-01-24

    The purpose of this design calculation is to determine the demand on the waste system and to size the sanitary sewer line serving the Shop Building No.5006 in accordance with the Uniform Plumbing Code (Section 4.4.1) and US Department of Energy Order 6430.1A-1540 (Section 4.4.2).

  13. Changes in water quality parameters due to in-sewer processes.

    PubMed

    Boxall, J; Shepherd, W; Guymer, I; Fox, K

    2003-01-01

    Combined sewer systems contain a large number of organic and inorganic pollutants from both domestic and industrial sources. These pollutants are often retained within the combined sewer system for significant lengths of time before entering sewage treatment works, or being spilt to a watercourse via a combined sewer overflow (CSO) during storm conditions. Currently little knowledge exists concerning the effects of in sewer processes on pollutants. Understanding of in-sewer processes is important for the effective and efficient design of treatment works and CSO chambers and for impact assessments on receiving waters. A series of studies covering storm and dry weather flow conditions were undertaken with the aim of investigating the nature of in-sewer processes. These studies consisted of marking a body of water with a fluorescent tracer. The tracer was then monitored at a series of downstream sites, and discrete samples collected from the body of water as it progressed through the sewer. The samples were analysed for water quality parameters and these results investigated in tandem with the detailed hydraulic information gained through the tracer studies. The results highlight the hydraulic differences between storm and dry weather conditions such as increased travel times and mixing under storm conditions. The Advection Dispersion Equation (ADE) and Aggregated Dead Zone (ADZ) model parameters have been quantified for the tracer data. The ADE mixing coefficient is shown to increase by an order of magnitude for storm conditions. The ADZ dispersive fraction parameter is shown to be approximately constant with flow. Chemical reactions and decay within the sewer system were found to be consistent with oxygen limitation.

  14. Sewer solids separation by sedimentation--the problem of modeling, validation and transferability.

    PubMed

    Kutzner, R; Brombach, H; Geiger, W F

    2007-01-01

    Sedimentation of sewer solids in tanks, ponds and similar devices is the most relevant process for the treatment of stormwater and combined sewer overflows in urban collecting systems. In the past a lot of research work was done to develop deterministic models for the description of this separation process. But these modern models are not commonly accepted in Germany until today. Water Authorities are sceptical with regard to model validation and transferability. Within this paper it is checked whether this scepticism is reasonable. A framework-proposal for the validation of mathematical models with zero or one dimensional spatial resolution for particle separation processes for stormwater and combined sewer overflow treatment is presented. This proposal was applied to publications of repute on sewer solids separation by sedimentation. The result was that none of the investigated models described in literature passed the validation entirely. There is an urgent need for future research in sewer solids sedimentation and remobilization!

  15. The effect of inclusion of inlets in dual drainage modelling

    NASA Astrophysics Data System (ADS)

    Chang, Tsang-Jung; Wang, Chia-Ho; Chen, Albert S.; Djordjević, Slobodan

    2018-04-01

    In coupled sewer and surface flood modelling approaches, the flow process in gullies is often ignored although the overland flow is drained to sewer network via inlets and gullies. Therefore, the flow entering inlets is transferred to the sewer network immediately, which may lead to a different flood estimation than the reality. In this paper, we compared two modelling approach with and without considering the flow processes in gullies in the coupled sewer and surface modelling. Three historical flood events were adopted for model calibration and validation. The results showed that the inclusion of flow process in gullies can further improve the accuracy of urban flood modelling.

  16. Online dissolved methane and total dissolved sulfide measurement in sewers.

    PubMed

    Liu, Yiwen; Sharma, Keshab R; Fluggen, Markus; O'Halloran, Kelly; Murthy, Sudhir; Yuan, Zhiguo

    2015-01-01

    Recent studies using short-term manual sampling of sewage followed by off-line laboratory gas chromatography (GC) measurement have shown that a substantial amount of dissolved methane is produced in sewer systems. However, only limited data has been acquired to date due to the low frequency and short span of this method, which cannot capture the dynamic variations of in-sewer dissolved methane concentrations. In this study, a newly developed online measuring device was used to monitor dissolved methane concentrations at the end of a rising main sewer network, over two periods of three weeks each, in summer and early winter, respectively. This device uses an online gas-phase methane sensor to measure methane under equilibrium conditions after being stripped from the sewage. The data are then converted to liquid-phase methane concentrations according to Henry's Law. The detection limit and range are suitable for sewer application and can be adjusted by varying the ratio of liquid-to-gas phase volume settings. The measurement presented good linearity (R² > 0.95) during field application, when compared to off-line measurements. The overall data set showed a wide variation in dissolved methane concentration of 5-15 mg/L in summer and 3.5-12 mg/L in winter, resulting in a significant average daily production of 24.6 and 19.0 kg-CH₄/d, respectively, from the network with a daily average sewage flow of 2840 m³/day. The dissolved methane concentration demonstrated a clear diurnal pattern coinciding with flow and sulfide fluctuation, implying a relationship with the wastewater hydraulic retention time (HRT). The total dissolved sulfide (TDS) concentration in sewers can be determined simultaneously with the same principle.

  17. Total energy food plant 21 million gallon ethanol facility

    NASA Astrophysics Data System (ADS)

    1981-10-01

    The Phase I Engineering study includes the following: process description, waste water treatment plant, material summary, energy chart, capital cost estimate, equipment list, personnel requirements, drawings list, specifications list, and project schedule. The economic and financial feasibility of the technical process, and environmental, health, safety, and socio-economic assessments for the project are reported. The costs for extending the following utilities to the property line of the selected site are presented: potable water, sewer system, electricity, roads for truck traffic, and rail service.

  18. Source, Transport, and Fate of Groundwater Contamination at Site 45, Marine Corps Recruit Depot, Parris Island, South Carolina

    USGS Publications Warehouse

    Vroblesky, Don A.; Petkewich, Matthew D.; Landmeyer, James E.; Lowery, Mark A.

    2009-01-01

    Groundwater contamination by tetrachloroethene and its dechlorination products is present in two partially intermingled plumes in the surficial aquifer near a former dry-cleaning facility at Site 45, Marine Corps Recruit Depot, Parris Island, South Carolina. The northern plume originates from the vicinity of former above-ground storage tanks. Free-phase tetrachloroethene from activities in this area entered the groundwater and the storm sewer. The southern plume originates at a nearby new dry-cleaning facility, but probably was the result of contamination released to the aquifer from a leaking sanitary sewer line from the former dry-cleaning facility. Discharge of dissolved groundwater contamination is primarily to leaking storm sewers below the water table. Extensive biodegradation of the contamination takes place in the surficial aquifer; however, the biodegradation is insufficient to reduce trichloroethene to less than milligram-per-liter concentrations prior to discharging into the storm sewers. The groundwater volatile organic compounds entering the storm sewers are substantially diluted by tidal flushing upon entry and are subject to volatilization as they are transported through the storm sewer to a discharge point in a tributary to Ballast Creek. TCE concentrations of about 2-6 micrograms per liter were present in storm-sewer water near the discharge point (sampled at manhole STS26). On three out of four sampling events at manhole STS14, the storm-sewer water contained no vinyl chloride. During a time of relatively high groundwater levels, however, 20 micrograms per liter of vinyl chloride was present in STS14 storm-sewer water. Because groundwater leaks into that storm sewer and because the storm sewer upgradient from manhole STS14 is adjacent to part of the aquifer where 2,290 micrograms per liter of vinyl chloride have been detected, there is a potential for substantially increased concentrations of vinyl chloride to discharge at the storm-sewer outfall under conditions of high groundwater levels and low tidal flushing. In addition, the observation that free-phase tetrachloroethene may have entered the storm-sewer system during the 1994 discharge means that dense nonaqueous phase liquid tetrachloroethene could have leaked from various parts of the storm sewer or discharged to surface water at the storm-sewer outfall.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Departmentmore » of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field.« less

  20. 32 CFR 552.33 - Estates and methods of acquisition.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... similar provision will be by letter from the Chief of Engineers to the owner of the property, based upon a...” in connection with a military public works project, prior to express authorization by law for the..., power lines, communication lines, water lines, and sewer lines will be the same as prescribed in...

  1. 32 CFR 552.33 - Estates and methods of acquisition.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... similar provision will be by letter from the Chief of Engineers to the owner of the property, based upon a...” in connection with a military public works project, prior to express authorization by law for the..., power lines, communication lines, water lines, and sewer lines will be the same as prescribed in...

  2. 32 CFR 552.33 - Estates and methods of acquisition.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... similar provision will be by letter from the Chief of Engineers to the owner of the property, based upon a...” in connection with a military public works project, prior to express authorization by law for the..., power lines, communication lines, water lines, and sewer lines will be the same as prescribed in...

  3. 32 CFR 552.33 - Estates and methods of acquisition.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... similar provision will be by letter from the Chief of Engineers to the owner of the property, based upon a...” in connection with a military public works project, prior to express authorization by law for the..., power lines, communication lines, water lines, and sewer lines will be the same as prescribed in...

  4. Transformation and Sorption of Illicit Drug Biomarkers in Sewer Systems: Understanding the Role of Suspended Solids in Raw Wastewater.

    PubMed

    Ramin, Pedram; Libonati Brock, Andreas; Polesel, Fabio; Causanilles, Ana; Emke, Erik; de Voogt, Pim; Plósz, Benedek Gy

    2016-12-20

    Sewer pipelines, although primarily designed for sewage transport, can also be considered as bioreactors. In-sewer processes may lead to significant variations of chemical loadings from source release points to the treatment plant influent. In this study, we assessed in-sewer utilization of growth substrates (primary metabolic processes) and transformation of illicit drug biomarkers (secondary metabolic processes) by suspended biomass. Sixteen drug biomarkers were targeted, including mephedrone, methadone, cocaine, heroin, codeine, and tetrahydrocannabinol (THC) and their major human metabolites. Batch experiments were performed under aerobic and anaerobic conditions using raw wastewater. Abiotic biomarker transformation and partitioning to suspended solids and reactor wall were separately investigated under both redox conditions. A process model was identified by combining and extending the Wastewater Aerobic/anaerobic Transformations in Sewers (WATS) model and Activated Sludge Model for Xenobiotics (ASM-X). Kinetic and stoichiometric model parameters were estimated using experimental data via the Bayesian optimization method DREAM (ZS) . Results suggest that biomarker transformation significantly differs from aerobic to anaerobic conditions, and abiotic conversion is the dominant mechanism for many of the selected substances. Notably, an explicit description of biomass growth during batch experiments was crucial to avoid significant overestimation (up to 385%) of aerobic biotransformation rate constants. Predictions of in-sewer transformation provided here can reduce the uncertainty in the estimation of drug consumption as part of wastewater-based epidemiological studies.

  5. Disparities in Water and Sewer Services in North Carolina: An Analysis of the Decision-Making Process

    PubMed Central

    Gibson, Jacqueline MacDonald

    2015-01-01

    Objectives. We examined the factors that affect access to municipal water and sewer service for unincorporated communities relying on wells and septic tanks. Methods. Using a multisite case study design, we conducted in-depth, semistructured interviews with 25 key informants from 3 unincorporated communities in Hoke, New Hanover, and Transylvania counties, North Carolina, July through September 2013. Interviewees included elected officials, health officials, utility providers, and community members. We coded the interviews in ATLAS.ti to identify common themes. Results. Financing for water and sewer service emerged as the predominant factor that influenced decisions to extend these services. Improved health emerged as a minor factor, suggesting that local officials may not place a high emphasis on the health benefits of extending public water and sewer services. Awareness of failed septic systems in communities can prompt city officials to extend sewer service to these areas; however, failed systems are often underreported. Conclusions. Understanding the health costs and benefits of water and sewer extension and integrating these findings into the local decision-making process may help address disparities in access to municipal services. PMID:26270307

  6. Optimization of the central automatic control of a small Dutch sewer system

    NASA Astrophysics Data System (ADS)

    Kolechkina, A. G.; Hoes, O. A. C.

    2012-04-01

    A sewer control system was developed in the context of a subsidized project aiming at improvement of surface water quality by control of sewer systems and surface water systems. The project was coordinated by the local water board, "Waterschap Hollandse Delta". Other participants were Delft University of Technology, Deltares and the municipalities Strijen, Cromstrijen, Westmaas, Oud Beijerland and Piershil. As part of the project there were two pilot implementations where a central automatic controller was coupled to the existing SCADA system. For these two pilots the system is now operational. A Dutch urban area in the western part of the Netherlands is usually part of a polder, which is effectively an artificially drained catchment. The urban area itself is split into small subcatchments that manage runoff in different ways. In all cases a large fraction goes into the natural hydrological cycle, but, depending on the design of the local sewer system, a larger or smaller part finds its way into the sewer system. Proper control of this flow is necessary to control surface water quality and to avoid health risks from flow from the sewer into the streets. At each time step the controller switches pumps to distribute the remaining water in the system at the end of the time step over the different subcatchments. The distribution is created based on expert judgment of the relative vulnerability and subcatchment sewer system water quality. It is implemented in terms curves of total system stored volume versus subcatchment stored volume. We describe the process of the adaptation of a controller to two different sewer systems and the understanding of the artificial part of the catchment we gained during this process. In the process of adaptation the type of sewer system (combined foul water and storm water transport or separate foul water and storm water transport) played a major role.

  7. Remaining Sites Verification Package for the 1607-B2 Septic System and 100-B-14:2 Sanitary Sewer System, Waste Site Reclassification Form 2004-006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. M. Dittmer

    The 100-B-14:2 subsite encompasses the former sanitary sewer feeder lines associated with the 1607-B2 and 1607-B7 septic systems. Feeder lines associated with the 185/190-B building have also been identified as the 100-B-14:8 subsite, and feeder lines associated with the 1607-B7 septic system have also been identified as the 100-B-14:9 subsite. These two subsites have been administratively cancelled to resolve the redundancy. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and themore » Columbia River.« less

  8. Assessment of erosion and sedimentation dynamic in a combined sewer network using online turbidity monitoring.

    PubMed

    Bersinger, T; Le Hécho, I; Bareille, G; Pigot, T

    2015-01-01

    Eroded sewer sediments are a significant source of organic matter discharge by combined sewer overflows. Many authors have studied the erosion and sedimentation processes at the scale of a section of sewer pipe and over short time periods. The objective of this study was to assess these processes at the scale of an entire sewer network and over 1 month, to understand whether phenomena observed on a small scale of space and time are still valid on a larger scale. To achieve this objective the continuous monitoring of turbidity was used. First, the study of successive rain events allows observation of the reduction of the available sediment and highlights the widely different erosion resistance for the different sediment layers. Secondly, calculation of daily chemical oxygen demand (COD) fluxes during the entire month was performed showing that sediment storage in the sewer pipe after a rain period is important and stops after 5 days. Nevertheless, during rainfall events, the eroded fluxes are more important than the whole sewer sediment accumulated during a dry weather period. This means that the COD fluxes promoted by runoff are substantial. This work confirms, with online monitoring, most of the conclusions from other studies on a smaller scale.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Wade C.

    Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 andmore » S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.« less

  10. Effect of temperature on anoxic sulfide oxidation and denitrification in the bulk wastewater phase of sewer networks.

    PubMed

    Mathioudakis, V L; Aivasidis, A

    2009-01-01

    Artificial dosage of nitrate in sewer networks is considered as one of the most effective methods for odor and corrosion control. However, there is limited knowledge on the effect of temperature on the transformations that takes place during anoxic conditions. Thus, two groups of batch experiments were conducted to gain insight in the involved processes in bulk phase of a septic municipal wastewater. It can be concluded that sewer denitrification, in bulk phase, can be simplified in three stages. According to the experimental results, nitrate or nitrite is utilized for autotrophic denitrification with sulfide, while heterotrophic utilization is initiated after the completion of anoxic sulfide oxidation. Moreover, temperature is proved to have a significant impact on sewer denitrification kinetic profile, as it determines the extent of temporal nitrite accumulation. The temperature coefficient of each anoxic process, including sulfide oxidation, nitrate utilization and denitrification/nitrite utilization is experimentally calculated and temperature dependent equations are developed, providing the rate of all anoxic processes in bulk phase of sewer wastewater, in any given temperature.

  11. Vision-based system for the control and measurement of wastewater flow rate in sewer systems.

    PubMed

    Nguyen, L S; Schaeli, B; Sage, D; Kayal, S; Jeanbourquin, D; Barry, D A; Rossi, L

    2009-01-01

    Combined sewer overflows and stormwater discharges represent an important source of contamination to the environment. However, the harsh environment inside sewers and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. In the following, we present and evaluate an in situ system for the monitoring of water flow in sewers based on video images. This paper focuses on the measurement of the water level based on image-processing techniques. The developed image-based water level algorithms identify the wall/water interface from sewer images and measure its position with respect to real world coordinates. A web-based user interface and a 3-tier system architecture enable the remote configuration of the cameras and the image-processing algorithms. Images acquired and processed by our system were found to reliably measure water levels and thereby to provide crucial information leading to better understand particular hydraulic behaviors. In terms of robustness and accuracy, the water level algorithm provided equal or better results compared to traditional water level probes in three different in situ configurations.

  12. Acoustic measurement and morphological features of organic sediment deposits in combined sewer networks.

    PubMed

    Carnacina, Iacopo; Larrarte, Frédérique; Leonardi, Nicoletta

    2017-04-01

    The performance of sewer networks has important consequences from an environmental and social point of view. Poor functioning can result in flood risk and pollution at a large scale. Sediment deposits forming in sewer trunks might severely compromise the sewer line by affecting the flow field, reducing cross-sectional areas, and increasing roughness coefficients. In spite of numerous efforts, the morphological features of these depositional environments remain poorly understood. The interface between water and sediment remains inefficiently identified and the estimation of the stock of deposit is frequently inaccurate. In part, this is due to technical issues connected to difficulties in collecting accurate field measurements without disrupting existing morphologies. In this paper, results from an extensive field campaign are presented; during the campaign a new survey methodology based on acoustic techniques has been tested. Furthermore, a new algorithm for the detection of the soil-water interface, and therefore for the correct esteem of sediment stocks is proposed. Finally, results in regard to bed topography, and morphological features at two different field sites are presented and reveal that a large variability in bed forms is present along sewer networks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Prioritizing sewer rehabilitation projects using AHP-PROMETHEE II ranking method.

    PubMed

    Kessili, Abdelhak; Benmamar, Saadia

    2016-01-01

    The aim of this paper is to develop a methodology for the prioritization of sewer rehabilitation projects for Algiers (Algeria) sewer networks to support the National Sanitation Office in its challenge to make decisions on prioritization of sewer rehabilitation projects. The methodology applies multiple-criteria decision making. The study includes 47 projects (collectors) and 12 criteria to evaluate them. These criteria represent the different issues considered in the prioritization of the projects, which are structural, hydraulic, environmental, financial, social and technical. The analytic hierarchy process (AHP) is used to determine weights of the criteria and the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE II) method is used to obtain the final ranking of the projects. The model was verified using the sewer data of Algiers. The results have shown that the method can be used for prioritizing sewer rehabilitation projects.

  14. Effects of in-sewer processes: a stochastic model approach.

    PubMed

    Vollertsen, J; Nielsen, A H; Yang, W; Hvitved-Jacobsen, T

    2005-01-01

    Transformations of organic matter, nitrogen and sulfur in sewers can be simulated taking into account the relevant transformation and transport processes. One objective of such simulation is the assessment and management of hydrogen sulfide formation and corrosion. Sulfide is formed in the biofilms and sediments of the water phase, but corrosion occurs on the moist surfaces of the sewer gas phase. Consequently, both phases and the transport of volatile substances between these phases must be included. Furthermore, wastewater composition and transformations in sewers are complex and subject to high, natural variability. This paper presents the latest developments of the WATS model concept, allowing integrated aerobic, anoxic and anaerobic simulation of the water phase and of gas phase processes. The resulting model is complex and with high parameter variability. An example applying stochastic modeling shows how this complexity and variability can be taken into account.

  15. Monitoring in inline storage sewers for stormwater treatment to determine efficiencies.

    PubMed

    Frehmann, T; Mietzel, T; Kutzner, R; Spengler, B; Geiger, W F

    2004-01-01

    A special structure of combined sewer overflow tanks is the inline storage sewer with downstream discharge (SKU). This layout has the advantage that besides the sewer system, no other structures are required for storm water treatment. Consequently only very little space is required and compared to combined sewer overflow tanks, there is an enormous potential in reducing costs during construction. To investigate the efficiency of an inline storage sewer, a monitoring station was established in Dortmund-Scharnhorst, Germany. The monitoring station was in operation for a period of 2.5 years. Within this period water samples were taken during a total of 20 discharge events. Besides the complete hydraulic data collection, seven water samplers took more than 5,000 water samples during dry and wet weather. This adds up to a total of more than 20,000 individual lab analyses. The average of the total efficiency for the SKU-West is 86%. 29% of this efficiency can be attributed to the throttle flow. The remaining 57% can be divided into a part of 48% that can be attributed to the process storage and 9% that can be attributed to sedimentation and erosion process.

  16. Simulation of sulfide buildup in wastewater and atmosphere of sewer networks.

    PubMed

    Nielsen, A H; Yongsiri, C; Hvitved-Jacobsen, T; Vollertsen, J

    2005-01-01

    A model concept for prediction of sulfide buildup in sewer networks is presented. The model concept is an extension to--and a further development of--the WATS model (Wastewater Aerobic-anaerobic Transformations in Sewers), which has been developed by Hvitved-Jacobsen and co-workers at Aalborg University. In addition to the sulfur cycle, the WATS model simulates changes in dissolved oxygen and carbon fractions of different biodegradability. The sulfur cycle was introduced via six processes: 1. sulfide production taking place in the biofilm covering the permanently wetted sewer walls; 2. biological sulfide oxidation in the permanently wetted biofilm; 3. chemical and biological sulfide oxidation in the water phase; 4. sulfide precipitation with metals present in the wastewater; 5. emission of hydrogen sulfide to the sewer atmosphere and 6. adsorption and oxidation of hydrogen sulfide on the moist sewer walls where concrete corrosion may take place.

  17. Hydrogen sulfide emission in sewer networks: a two-phase modeling approach to the sulfur cycle.

    PubMed

    Yongsiri, C; Vollertsen, J; Hvitved-Jacobsen, T

    2004-01-01

    Wherever transport of anaerobic wastewater occurs, potential problems associated with hydrogen sulfide in relation to odor nuisance, health risk and corrosion exist. Improved understanding of prediction of hydrogen sulfide emission into the sewer atmosphere is needed for better evaluation of such problems in sewer networks. A two-phase model for emission of hydrogen sulfide along stretches of gravity sewers is presented to estimate the occurrence of both sulfide in the water phase and hydrogen sulfide in the sewer atmosphere. The model takes into account air-water mass transfer of hydrogen sulfide and interactions with other processes in the sulfur cycle. Various emission scenarios are simulated to illustrate the release characteristics of hydrogen sulfide.

  18. Fibre-optic distributed temperature sensing in combined sewer systems.

    PubMed

    Schilperoort, R P S; Clemens, F H L R

    2009-01-01

    This paper introduces the application of fibre-optic distributed temperature sensing (DTS) in combined sewer systems. The DTS-technique uses a fibre-optic cable that is inserted into a combined sewer system in combination with a laser instrument that performs measurements and logs the data. The DTS-technique allows monitoring in-sewer temperatures with dense spatial and temporal resolutions. The installation of a fibre-optic cable in a combined sewer system has proven feasible. The use of a single instrument in an easy accessible and safe location that can simultaneously monitor up to several hundreds of monitoring locations makes the DTS set-up easy in use and nearly free of maintenance. Temperature data from a one-week monitoring campaign in an 1,850 m combined sewer system shows the level of detail with which in-sewer processes that affect wastewater temperatures can be studied. Individual discharges from house-connections can be tracked in time and space. With a dedicated cable configuration the confluence of wastewater flows can be observed with a potential to derive the relative contributions of contributary flows to a total flow. Also, the inflow and in-sewer propagation of stormwater can be monitored.

  19. Assessing the efficiency of different CSO positions based on network graph characteristics.

    PubMed

    Sitzenfrei, R; Urich, C; Möderl, M; Rauch, W

    2013-01-01

    The technical design of urban drainage systems comprises two major aspects: first, the spatial layout of the sewer system and second, the pipe-sizing process. Usually, engineers determine the spatial layout of the sewer network manually, taking into account physical features and future planning scenarios. Before the pipe-sizing process starts, it is important to determine locations of possible weirs and combined sewer overflows (CSOs) based on, e.g. distance to receiving water bodies or to a wastewater treatment plant and available space for storage units. However, positions of CSOs are also determined by topological characteristics of the sewer networks. In order to better understand the impact of placement choices for CSOs and storage units in new systems, this work aims to determine case unspecific, general rules. Therefore, based on numerous, stochastically generated virtual alpine sewer systems of different sizes it is investigated how choices for placement of CSOs and storage units have an impact on the pipe-sizing process (hence, also on investment costs) and on technical performance (CSO efficiency and flooding). To describe the impact of the topological positions of these elements in the sewer networks, graph characteristics are used. With an evaluation of 2,000 different alpine combined sewer systems, it was found that, as expected, with CSOs at more downstream positions in the network, greater construction costs and better performance regarding CSO efficiency result. At a specific point (i.e. topological network position), no significant difference (further increase) in construction costs can be identified. Contrarily, the flooding efficiency increases with more upstream positions of the CSOs. Therefore, CSO and flooding efficiency are in a trade-off conflict and a compromise is required.

  20. Improved sulfide mitigation in sewers through on-line control of ferrous salt dosing.

    PubMed

    Ganigué, Ramon; Jiang, Guangming; Liu, Yiqi; Sharma, Keshab; Wang, Yue-Cong; Gonzalez, José; Nguyen, Tung; Yuan, Zhiguo

    2018-05-15

    Water utilities worldwide spend annually billions of dollars to control sulfide-induced corrosion in sewers. Iron salts chemically oxidize and/or precipitate dissolved sulfide in sewage and are especially used in medium- and large-size sewers. Iron salt dosing rates are defined ad hoc, ignoring variation in sewage flows and sulfide levels. This often results in iron overdosing or poor sulfide control. Online dosing control can adjust the chemical dosing rates to current (and future) state of the sewer system, allowing high-precision, stable and cost-effective sulfide control. In this paper, we report a novel and robust online control strategy for the dosing of ferrous salt in sewers. The control considers the fluctuation of sewage flow, pH, sulfide levels and also the perturbation from rainfall. Sulfide production in the pipe is predicted using auto-regressive models (AR) based on current flow measurements, which in turn can be used to determine the dose of ferrous salt required for cost-effective sulfide control. Following comprehensive model-based assesment, the control was successfully validated and its effectiveness demonstrated in a 3-week field trial. The online control algorithm controlled sulfide below the target level (0.5 mg S/L) while reducing chemical dosing up to 30%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Multivariate probability distribution for sewer system vulnerability assessment under data-limited conditions.

    PubMed

    Del Giudice, G; Padulano, R; Siciliano, D

    2016-01-01

    The lack of geometrical and hydraulic information about sewer networks often excludes the adoption of in-deep modeling tools to obtain prioritization strategies for funds management. The present paper describes a novel statistical procedure for defining the prioritization scheme for preventive maintenance strategies based on a small sample of failure data collected by the Sewer Office of the Municipality of Naples (IT). Novelty issues involve, among others, considering sewer parameters as continuous statistical variables and accounting for their interdependences. After a statistical analysis of maintenance interventions, the most important available factors affecting the process are selected and their mutual correlations identified. Then, after a Box-Cox transformation of the original variables, a methodology is provided for the evaluation of a vulnerability map of the sewer network by adopting a joint multivariate normal distribution with different parameter sets. The goodness-of-fit is eventually tested for each distribution by means of a multivariate plotting position. The developed methodology is expected to assist municipal engineers in identifying critical sewers, prioritizing sewer inspections in order to fulfill rehabilitation requirements.

  2. Identification of potential sewer mining locations: a Monte-Carlo based approach.

    PubMed

    Tsoukalas, I K; Makropoulos, C K; Michas, S N

    2017-12-01

    Rapid urbanization affecting demand patterns, coupled with potential water shortages due to supply side impacts of climatic changes, has led to the emergence of new technologies for water and wastewater reuse. Sewer mining (SM) is a novel decentralized option that could potentially provide non-potable water for urban uses, including for example the irrigation of urban green spaces, providing a mid-scale solution to effective wastewater reuse. SM is based on extracting wastewater from local sewers and treatment at the point of demand and entails in some cases the return of treatment residuals back to the sewer system. Several challenges are currently in the way of such applications in Europe, including public perception, inadequate regulatory frameworks and engineering issues. In this paper we consider some of these engineering challenges, looking at the sewer network as a system where multiple physical, biological and chemical processes take place. We argue that prior to implementing SM, the dynamics of the sewer system should be investigated in order to identify optimum ways of deploying SM without endangering the reliability of the system. Specifically, both wastewater extraction and sludge return could result in altering the biochemical process of the network, thus unintentionally leading to degradation of the sewer infrastructure. We propose a novel Monte-Carlo based method that takes into account both spatial properties and water demand characteristics of a given area of SM deployment while simultaneously accounting for the variability of sewer network dynamics in order to identify potential locations for SM implementation. The outcomes of this study suggest that the method can provide rational results and useful guidelines for upscale SM technologies at a city level.

  3. Predictive optimal control of sewer networks using CORAL tool: application to Riera Blanca catchment in Barcelona.

    PubMed

    Puig, V; Cembrano, G; Romera, J; Quevedo, J; Aznar, B; Ramón, G; Cabot, J

    2009-01-01

    This paper deals with the global control of the Riera Blanca catchment in the Barcelona sewer network using a predictive optimal control approach. This catchment has been modelled using a conceptual modelling approach based on decomposing the catchments in subcatchments and representing them as virtual tanks. This conceptual modelling approach allows real-time model calibration and control of the sewer network. The global control problem of the Riera Blanca catchment is solved using a optimal/predictive control algorithm. To implement the predictive optimal control of the Riera Blanca catchment, a software tool named CORAL is used. The on-line control is simulated by interfacing CORAL with a high fidelity simulator of sewer networks (MOUSE). CORAL interchanges readings from the limnimeters and gate commands with MOUSE as if it was connected with the real SCADA system. Finally, the global control results obtained using the predictive optimal control are presented and compared against the results obtained using current local control system. The results obtained using the global control are very satisfactory compared to those obtained using the local control.

  4. Bacteriophage ecology in a small community sewer system related to their indicative role in sewage pollution of drinking water.

    PubMed

    Gino, Efrat; Starosvetsky, Jeana; Armon, Robert

    2007-10-01

    In view of various studies looking for the merit of coliphages as indicators of water pollution with viruses originating from faecal material, a small agricultural community (population of approximately 1500 inhabitants of all ages, 2-3 km from Haifa) was selected in order to understand these bacteriophage ecology (F-RNA and somatic coliphages) in its sewer and oxidation pond system. Along the sewer lines, it was possible to isolate constantly both bacteriophage types (F-RNA and somatic coliphages) at 10(2)-10(4) plaque-forming units (pfu) ml(-1). The average numbers of somatic and F-RNA phages isolated from oxidation pond were 10(3)-10(4) pfu ml(-1); however, somatic coliphages were undetectable for several months (April-August). Significant high correlation (0.944 < R(2) < 0.99) was found between increased anionic detergent concentrations and F-RNA coliphage numbers. Infants less than 1 year old excreted both phage types and few only F-RNA coliphages (at high numbers > 10(5) pfu g(-1)) for up to 1 year. The excretion of F-RNA coliphages was highly linked to Escherichia coli F(+) harborage in the intestinal track as found in their faecal content. Finally, three bacterial hosts E. coli F(+), F(-) and CN(13) tested for survivability in sewage filtrate revealed that E. coli F(+) had the highest survivability under these conditions. Presence of somatic and F male-specific phages in sewer lines of a small community are influenced by several factors such as: anionic detergents, nutrients, temperature, source (mainly infants), shedding and survival capability of the host strain. Better understanding of coliphages ecology in sewer systems can enhance our evaluation of these proposed indicator/index microorganisms used in tracking environmental pollution of water, soil and crop contamination with faecal material containing enteric viruses.

  5. 13 CFR 314.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... includes land that is improved by the construction of Project infrastructure such as, but not limited to, roads, sewers and water lines that are not situated on or under the land, where the infrastructure...

  6. 78 FR 66852 - Housing Assistance Due to Structural Damage

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... have the maximum IHP award for housing assistance, there would be no additional money available to... a mobile home, and reconnecting or resetting mobile home sewer, water, electrical and fuel lines and...

  7. 24 CFR 1003.202 - Eligible rehabilitation and preservation activities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the efficient use of water through such means as water saving faucets and shower heads and repair of water leaks; (6) Connection of residential structures to water distribution lines or local sewer...

  8. 44 CFR 206.117 - Housing assistance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... owned bridge, wells and/or septic systems) damaged by a major disaster. (ii) The type of repair FEMA... home, and reconnecting or resetting mobile home sewer, water, electrical and fuel lines and tanks; and...

  9. 78 FR 41803 - Notice of Lodging of Proposed Amendment to Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-11

    ... original 2012 consent decree, the Metropolitan St. Louis Sewer District (``MSD'') agreed to undertake... specific combined sewer overflow control measures. MSD still is in the process of complying with the 2012...

  10. Functional evaluation of pollutant transformation in sediment from combined sewer system.

    PubMed

    Shi, Xuan; Ngo, Huu Hao; Sang, Langtao; Jin, Pengkang; Wang, Xiaochang C; Wang, Guanghua

    2018-07-01

    In this study, a pilot combined sewer system was constructed to characterize the pollutant transformation in sewer sediment. The results showed that particulate contaminants deposited from sewage could be transformed into dissolved matter by distinct pollutant transformation pathways. Although the oxidation-reduction potential (ORP) was varied from -80 mV to -340 mV in different region of the sediment, the fermentation was the dominant process in all regions of the sediment, which induced hydrolysis and decomposition of particulate contaminants. As a result, the accumulation of dissolved organic matter and the variation of ORP values along the sediment depth led to the depth-dependent reproduction characteristics of methanogens and sulfate-reducing bacteria, which were existed in the middle and deep layer of the sediment respectively. However, the diversity of nitrifying and polyphosphate-accumulating bacteria was low in sewer sediment and those microbial communities showed a non-significant correlation with nitrogen and phosphorus contaminants, which indicated that the enrichment of nitrogen and phosphorus contaminants was mainly caused by physical deposition process. Thus, this study proposed a promising pathway to evaluate pollutant transformation and can help provide theoretical foundation for urban sewer improvement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. The Ecology of Acidophilic Microorganisms in the Corroding Concrete Sewer Environment

    PubMed Central

    Li, Xuan; Kappler, Ulrike; Jiang, Guangming; Bond, Philip L.

    2017-01-01

    Concrete corrosion is one of the most significant problems affecting valuable sewer infrastructure on a global scale. This problem occurs in the aerobic zone of the sewer, where a layer of surface corrosion develops on the exposed concrete and the surface pH is typically lowered from around 11–10 (pristine concrete) to pH 2–4. Acidophilic microorganisms become established as biofilms within the concrete corrosion layer and enhance the loss of concrete mass. Until recently, the acidophilic community was considered to comprise relatively few species of microorganisms, however, the biodiversity of the corrosion community is now recognized as being extensive and varying from different sewer environmental conditions. The diversity of acidophiles in the corrosion communities includes chemolithoautotrophs, chemolithoheterotrophs, and chemoorganoheterotrophs. The activity of these microorganisms is strongly affected by H2S levels in the sewer gas phase, although CO2, organic matter, and iron in the corrosion layer influence this acidic ecosystem. This paper briefly presents the conditions within the sewer that lead to the development of concrete corrosion in that environment. The review focuses on the acidophilic microorganisms detected in sewer corrosion environments, and then summarizes their proposed functions and physiology, especially in relation to the corrosion process. To our knowledge, this is the first review of acidophilic corrosion microbial communities, in which, the ecology and the environmental conditions (when available) are considered. Ecological studies of sewer corrosion are limited, however, where possible, we summarize the important metabolic functions of the different acidophilic species detected in sewer concrete corrosion layers. It is evident that microbial functions in the acidic sewer corrosion environment can be linked to those occurring in the analogous acidic environments of acid mine drainage and bioleaching. PMID:28473816

  12. The Ecology of Acidophilic Microorganisms in the Corroding Concrete Sewer Environment.

    PubMed

    Li, Xuan; Kappler, Ulrike; Jiang, Guangming; Bond, Philip L

    2017-01-01

    Concrete corrosion is one of the most significant problems affecting valuable sewer infrastructure on a global scale. This problem occurs in the aerobic zone of the sewer, where a layer of surface corrosion develops on the exposed concrete and the surface pH is typically lowered from around 11-10 (pristine concrete) to pH 2-4. Acidophilic microorganisms become established as biofilms within the concrete corrosion layer and enhance the loss of concrete mass. Until recently, the acidophilic community was considered to comprise relatively few species of microorganisms, however, the biodiversity of the corrosion community is now recognized as being extensive and varying from different sewer environmental conditions. The diversity of acidophiles in the corrosion communities includes chemolithoautotrophs, chemolithoheterotrophs, and chemoorganoheterotrophs. The activity of these microorganisms is strongly affected by H 2 S levels in the sewer gas phase, although CO 2 , organic matter, and iron in the corrosion layer influence this acidic ecosystem. This paper briefly presents the conditions within the sewer that lead to the development of concrete corrosion in that environment. The review focuses on the acidophilic microorganisms detected in sewer corrosion environments, and then summarizes their proposed functions and physiology, especially in relation to the corrosion process. To our knowledge, this is the first review of acidophilic corrosion microbial communities, in which, the ecology and the environmental conditions (when available) are considered. Ecological studies of sewer corrosion are limited, however, where possible, we summarize the important metabolic functions of the different acidophilic species detected in sewer concrete corrosion layers. It is evident that microbial functions in the acidic sewer corrosion environment can be linked to those occurring in the analogous acidic environments of acid mine drainage and bioleaching.

  13. Groundwater infiltration, surface water inflow and sewerage exfiltration considering hydrodynamic conditions in sewer systems.

    PubMed

    Karpf, Christian; Hoeft, Stefan; Scheffer, Claudia; Fuchs, Lothar; Krebs, Peter

    2011-01-01

    Sewer systems are closely interlinked with groundwater and surface water. Due to leaks and regular openings in the sewer system (e.g. combined sewer overflow structures with sometimes reverse pressure conditions), groundwater infiltration and surface water inflow as well as exfiltration of sewage take place and cannot be avoided. In the paper a new hydrodynamic sewer network modelling approach will be presented, which includes--besides precipitation--hydrographs of groundwater and surface water as essential boundary conditions. The concept of the modelling approach and the models to describe the infiltration, inflow and exfiltration fluxes are described. The model application to the sewerage system of the City of Dresden during a flood event with complex conditions shows that the processes of infiltration, exfiltration and surface water inflows can be described with a higher reliability and accuracy, showing that surface water inflow causes a pronounced system reaction. Further, according to the simulation results, a high sensitivity of exfiltration rates on the in-sewer water levels and a relatively low influence of the dynamic conditions on the infiltration rates were found.

  14. Forensic applications of nitrogen and oxygen isotopes in tracing nitrate sources in urban environments

    USGS Publications Warehouse

    Silva, S.R.; Ging, P.B.; Lee, R.W.; Ebbert, J.C.; Tesoriero, A.J.; Inkpen, E.L.

    2002-01-01

    Ground and surface waters in urban areas are susceptible to nitrate contamination from septic systems, leaking sewer lines, and fertilizer applications. Source identification is a primary step toward a successful remediation plan in affected areas. In this respect, nitrogen and oxygen isotope ratios of nitrate, in conjunction with hydrologic data and water chemistry, have proven valuable in urban studies from Austin, Texas, and Tacoma, Washington. In Austin, stream water was sampled during stremflow and baseflow conditions to assess surface and subsurface sources of nitrate, respectively. In Tacoma, well waters were sampled in adjacent sewered and un-sewered areas to determine if locally high nitrate concentrations were caused by septic systems in the un-sewered areas. In both studies, sewage was identified as a nitrate source and mixing between sewage and other sources of nitrate was apparent. In addition to source identification, combined nitrogen and oxygen isotopes were important in determining the significance of denitrification, which can complicate source assessment by reducing nitrate concentrations and increasing ??15N values. The two studies illustrate the value of nitrogen and oxygen isotopes of nitrate for forensic applications in urban areas. ?? Published by Elsevier Science Ltd. on behalf of AEHS.

  15. 24 CFR 570.202 - Eligible rehabilitation and preservation activities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... increase the efficient use of water through such means as water savings faucets and shower heads and repair of water leaks; (6) Connection of residential structures to water distribution lines or local sewer...

  16. 36 CFR 51.51 - What special terms must I know to understand leasehold surrender interest?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., windows, rafters, roofing, framing, siding, lumber, insulation, wallpaper, paint, etc.). Because of their... and sewer lines) and constructed site improvements (e.g., paved roads, retaining walls, sidewalks...

  17. 36 CFR 51.51 - What special terms must I know to understand leasehold surrender interest?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., windows, rafters, roofing, framing, siding, lumber, insulation, wallpaper, paint, etc.). Because of their... and sewer lines) and constructed site improvements (e.g., paved roads, retaining walls, sidewalks...

  18. 36 CFR 51.51 - What special terms must I know to understand leasehold surrender interest?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., windows, rafters, roofing, framing, siding, lumber, insulation, wallpaper, paint, etc.). Because of their... and sewer lines) and constructed site improvements (e.g., paved roads, retaining walls, sidewalks...

  19. 24 CFR 92.206 - Eligible project costs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... lead-based paint activities, as required by part 35 of this title. (3) For both new construction and... on-site roads and sewer and water lines necessary to the development of the project. The project site...

  20. 36 CFR 51.51 - What special terms must I know to understand leasehold surrender interest?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., windows, rafters, roofing, framing, siding, lumber, insulation, wallpaper, paint, etc.). Because of their... and sewer lines) and constructed site improvements (e.g., paved roads, retaining walls, sidewalks...

  1. 36 CFR 51.51 - What special terms must I know to understand leasehold surrender interest?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., windows, rafters, roofing, framing, siding, lumber, insulation, wallpaper, paint, etc.). Because of their... and sewer lines) and constructed site improvements (e.g., paved roads, retaining walls, sidewalks...

  2. 24 CFR 92.206 - Eligible project costs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... lead-based paint activities, as required by part 35 of this title. (3) For both new construction and... on-site roads and sewer and water lines necessary to the development of the project. The project site...

  3. 24 CFR 92.206 - Eligible project costs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... lead-based paint activities, as required by part 35 of this title. (3) For both new construction and... on-site roads and sewer and water lines necessary to the development of the project. The project site...

  4. The effects of urbanization on the hydrochemistry of base flow within the Chattahoochee River Basin (Georgia, USA)

    NASA Astrophysics Data System (ADS)

    Rose, Seth

    2007-07-01

    SummaryA comprehensive network of stream data ( n = 50) was used to assess the effects of urbanization upon the hydrochemical variation within base flow in the Chattahoochee River Basin (CRB), Georgia (USA). Base flow solute concentrations (particularly sulfate, chloride, bicarbonate alkalinity, and sodium) increase with the degree of urbanization and any degree of urbanization within the Atlanta Metropolitan Region (AMR) results in elevated base flow solute concentrations. This suggests that there are pervasive low-level non-point sources of contamination such as septic tanks systems and leaky sewer lines affecting the chemistry of shallow groundwater throughout much of the AMR and CRB. Six groups or subsets representing the "rural-to-urban gradient" were defined, characterized by the following order of increasing solute concentrations: rural basins < Chattahoochee River. semi-urbanized basins < urbanized basins < urban basins with main sewer trunk lines < urbanized basins directly receiving treated effluent and combined sewer overflow (CSO) basins. There is a strong and unusual basin-wide correlation ( r2 values >0.79) between Na-K-Cl within the CRB that likely reflects the widespread input of electrolytes present in human wastes and wastewater. The most likely source and pathway for contaminant input involves the mobilization of salts, originally present in waste water, within the riparian or hypoheric zone.

  5. Identification of controlling factors for the initiation of corrosion of fresh concrete sewers.

    PubMed

    Jiang, Guangming; Sun, Xiaoyan; Keller, Jurg; Bond, Philip L

    2015-09-01

    The development of concrete corrosion in new sewer pipes undergoes an initiation process before reaching an active corrosion stage. This initiation period is assumed to last several months to years but the key factors affecting the process, and its duration, are not well understood. This study is therefore focused on this initial stage of the corrosion process and the effect of key environmental factors. Such knowledge is important for the effective management of corrosion in new sewers, as every year of life extension of such systems has a very high financial benefit. This long-term (4.5 year) study has been conducted in purpose-built corrosion chambers that closely simulated the sewer environment, but with control of three key environmental factors being hydrogen sulfide (H2S) gas phase concentration, relative humidity and air temperature. Fresh concrete coupons, cut from an industry-standard sewer pipe, were exposed to the corrosive conditions in the chambers, both in the gas phase and partially submerged in wastewater. A total of 36 exposure conditions were investigated to determine the controlling factors by regular retrieval of concrete coupons for detailed analysis of surface pH, sulfur compounds (elemental sulfur and sulfate) and concrete mass loss. Corrosion initiation times were thus determined for different exposure conditions. It was found that the corrosion initiation time of both gas-phase and partially-submerged coupons was positively correlated with the gas phase H2S concentration, but only at levels of 10 ppm or below, indicating that sulfide oxidation rate rather than the H2S concentration was the limiting factor during the initiation stage. Relative humidity also played a role for the corrosion initiation of the gas-phase coupons. However, the partially-submerged coupons were not affected by humidity as these coupons were in direct contact with the sewage and hence did have sufficient moisture to enable the microbial processes to proceed. The corrosion initiation time was also shortened by higher gas temperature due to its positive impact on reaction kinetics. These findings provide real opportunities for pro-active sewer asset management with the aim to delay the on-set of the corrosion processes, and hence extend the service life of sewers, through improved prediction and optimization capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. APPROACH TO "FURTHER-REASONABLE-PROGRESS" TO ATTAIN WATER QUALITY STANDARDS

    EPA Science Inventory

    Watershed managers in urban areas in the US are pursuing optimum strategies or plans for managing wastewater treatment plants, stormwater systems, sanitary sewer overflows (SSO) and combined sewer overflows (CSO). Often these strategies are based on an iterative process or a "fur...

  7. APPROACH TO "FURTHER-REASONABLE-PROGRESS" TO ATTAIN WATER QUALITY STANDARDS

    EPA Science Inventory

    Watershed managers in urban areas in the US are pursuing optimum strategies or plans for managing wastewater treatment plants, stormwater systems, sanitary sewer overflows (SSO) and combined sewer overflows (CSO). Often thes strategies are based on an iterative process or a "furt...

  8. A mathematical model to predict the effect of heat recovery on the wastewater temperature in sewers.

    PubMed

    Dürrenmatt, David J; Wanner, Oskar

    2014-01-01

    Raw wastewater contains considerable amounts of energy that can be recovered by means of a heat pump and a heat exchanger installed in the sewer. The technique is well established, and there are approximately 50 facilities in Switzerland, many of which have been successfully using this technique for years. The planning of new facilities requires predictions of the effect of heat recovery on the wastewater temperature in the sewer because altered wastewater temperatures may cause problems for the biological processes used in wastewater treatment plants and receiving waters. A mathematical model is presented that calculates the discharge in a sewer conduit and the spatial profiles and dynamics of the temperature in the wastewater, sewer headspace, pipe, and surrounding soil. The model was implemented in the simulation program TEMPEST and was used to evaluate measured time series of discharge and temperatures. It was found that the model adequately reproduces the measured data and that the temperature and thermal conductivity of the soil and the distance between the sewer pipe and undisturbed soil are the most sensitive model parameters. The temporary storage of heat in the pipe wall and the exchange of heat between wastewater and the pipe wall are the most important processes for heat transfer. The model can be used as a tool to determine the optimal site for heat recovery and the maximal amount of extractable heat. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Development of Sediment Deposition Height Capacity Equation in Sewer Networks

    NASA Astrophysics Data System (ADS)

    Song, Yangho; Jo, Deokjun; Lee, Jungho

    2017-04-01

    Sediment characteristics and transport processes in sewers are markedly different from river. There is a wide range of particle densities and smaller particle size variation in sewers. Sediment supply and the available erodible material are more limited in sewers, and the diverse hydraulic characteristics in sewer systems are more unsteady. Prevention of sewer sediment accumulation, which can cause major sewer operational problems, is imperative and has been an immense concern for engineers. The effects of sediment formation in sewer systems, an appropriate sediment transport modelling with the ability to determine the location and depth of sediment deposit is needed. It is necessary to design efficiently considering the transfer and settling phenomena of the sediment coming into the sewer systems. During transport in the sewer, the minimum shear flow velocity and possible shear stress at which the sediment is transported smoothly. However, the interaction of sediment and fluid within the sewer systems has been very complex and the rigorous theoretical handling of this problem has not been developed. It is derived from the empirical values obtained from the river bed. The basic theory that particles float is based on the balance between sedimentation of particles by gravity and turbulent diffusion of fluids. There are many variables related. Representative parameters include complex phenomena due to collisions between particles, particles and fluids, and interactions between particles and tube walls. In general, the main parameters that form the boundary between the main transport and sediment are particle size, density, volume fraction, pipe diameter and gravity. As the particle size and volume concentration increase, the minimum feed rate increases and the same tendency is observed for the change of the capillary diameter. Based on this tendency, this study has developed a sediment deposition height capacity formula to take into consideration the sewer discharge capacity. The main objective in undertaking this research is the assessment of the sediment scouring and transporting capacity of the discharged. Acknowledgements This research was supported by a grant(13AWMP-B066744-01) from Advanced Water Management Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government.

  10. 24 CFR 58.35 - Categorical exclusions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... capacity of more than 20 percent (e.g., replacement of water or sewer lines, reconstruction of curbs and... use is not changed, and the footprint of the building is not increased in a floodplain or in a wetland...

  11. Factors that influence properties of FOG deposits and their formation in sewer collection systems.

    PubMed

    Iasmin, Mahbuba; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J

    2014-02-01

    Understanding the formation of Fat, Oil, and Grease (FOG) deposits in sewer systems is critical to the sustainability of sewer collection systems since they have been implicated in causing sewerage blockages that leads to sanitary sewer overflows (SSOs). Recently, FOG deposits in sewer systems displayed strong similarities with calcium-based fatty acid salts as a result of a saponification reaction. The objective of this study was to quantify the factors that may affect the formation of FOG deposits and their chemical and rheological properties. These factors included the types of fats used in FSEs, environmental conditions (i.e. pH and temperature), and the source of calcium in sewer systems. The results of this study showed that calcium content in the calcium based salts seemed to depend on the solubility limit of the calcium source and influenced by pH and temperature conditions. The fatty acid profile of the calcium-based fatty acid salts produced under alkali driven hydrolysis were identical to the profile of the fat source and did not match the profile of field FOG deposits, which displayed a high fraction of palmitic, a long chain saturated fatty acid. It is hypothesized that selective microbial metabolism of fats and/or biologically induced hydrogenation may contribute to the FOG deposit makeup in sewer system. Therefore, selective removal of palmitic in pretreatment processes may be necessary prior to the discharge of FSE wastes into the sewer collection system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Anoxic control of odour and corrosion from sewer networks.

    PubMed

    Yang, W; Vollertsen, J; Hvitved-Jacobsen, T

    2004-01-01

    Anoxic processes can effectively control odour and corrosion in sewer networks. However, the absence of fundamental knowledge on the kinetics of anoxic transformation of sewage prevents the engineering applications of anoxic control in sewers. This paper focuss on a basic understanding of the anoxic transformations needed for a conceptual simulation of the water phase processes. Experiments conducted in batch reactors have shown that nitrite builds up in wastewater during denitrification. Part of the nitrate-reducing biomass is capable of utilizing nitrite after nitrate is depleted. Compared with aerobic transformation, anoxic processes have low values of maximum growth rate of the biomass and also a low endogenous respiration rate. Heterotrophic yield determined under anoxic conditions, at level of 0.25 mmol e-eq (mmol e-eq)(-1), accounted for less than 40% of the corresponding aerobic values.

  13. The erosion behaviour of biologically active sewer sediment deposits: observations from a laboratory study.

    PubMed

    Banasiak, Robert; Verhoeven, Ronny; De Sutter, Renaat; Tait, Simon

    2005-12-01

    The erosion behaviour of various fine-grained sediment deposits has been investigated in laboratory experiments. This work mainly focused on tests using sewer sediment in which strong biochemical reactions were observed during the deposit formation period. A small number of initial tests were conducted in which the deposits were made from mixtures of "clean" mineral and organic sediments. The erosion behaviour observed in these tests was compared with the erosion characteristics for sediments taken from deposits in a sewer. The impact of the biological processes on physical properties such as bulk density, water content, deposit structure and the erosive behaviour as a function of bed shear stress are quantified and discussed. Based on these observations it is believed that bio-processes weaken the strength of the in-pipe sediment deposits. A significantly weaker sediment surface layer was observed during deposition under quiescent oxygen-rich conditions. This resulted in a deposit with low shear strength which may be a cause of a first foul flush of suspended sediment when flow rates were increased. Comparison between tests with sewer sediments and the artificial representative surrogates suggested that the deposits of the later did not correctly simulate the depositional development and the resultant erosion patterns observed with the more bio-active sewer sediment.

  14. Improved wet weather wastewater influent modelling at Viikinmäki WWTP by on-line weather radar information.

    PubMed

    Heinonen, M; Jokelainen, M; Fred, T; Koistinen, J; Hohti, H

    2013-01-01

    Municipal wastewater treatment plant (WWTP) influent is typically dependent on diurnal variation of urban production of liquid waste, infiltration of stormwater runoff and groundwater infiltration. During wet weather conditions the infiltration phenomenon typically increases the risk of overflows in the sewer system as well as the risk of having to bypass the WWTP. Combined sewer infrastructure multiplies the role of rainwater runoff in the total influent. Due to climate change, rain intensity and magnitude is tending to rise as well, which can already be observed in the normal operation of WWTPs. Bypass control can be improved if the WWTP is prepared for the increase of influent, especially if there is some storage capacity prior to the treatment plant. One option for this bypass control is utilisation of on-line weather-radar-based forecast data of rainfall as an input for the on-line influent model. This paper reports the Viikinmäki WWTP wet weather influent modelling project results where gridded exceedance probabilities of hourly rainfall accumulations for the next 3 h from the Finnish Meteorological Institute are utilised as on-line input data for the influent model.

  15. Sewer deterioration modeling with condition data lacking historical records.

    PubMed

    Egger, C; Scheidegger, A; Reichert, P; Maurer, M

    2013-11-01

    Accurate predictions of future conditions of sewer systems are needed for efficient rehabilitation planning. For this purpose, a range of sewer deterioration models has been proposed which can be improved by calibration with observed sewer condition data. However, if datasets lack historical records, calibration requires a combination of deterioration and sewer rehabilitation models, as the current state of the sewer network reflects the combined effect of both processes. Otherwise, physical sewer lifespans are overestimated as pipes in poor condition that were rehabilitated are no longer represented in the dataset. We therefore propose the combination of a sewer deterioration model with a simple rehabilitation model which can be calibrated with datasets lacking historical information. We use Bayesian inference for parameter estimation due to the limited information content of the data and limited identifiability of the model parameters. A sensitivity analysis gives an insight into the model's robustness against the uncertainty of the prior. The analysis reveals that the model results are principally sensitive to the means of the priors of specific model parameters, which should therefore be elicited with care. The importance sampling technique applied for the sensitivity analysis permitted efficient implementation for regional sensitivity analysis with reasonable computational outlay. Application of the combined model with both simulated and real data shows that it effectively compensates for the bias induced by a lack of historical data. Thus, the novel approach makes it possible to calibrate sewer pipe deterioration models even when historical condition records are lacking. Since at least some prior knowledge of the model parameters is available, the strength of Bayesian inference is particularly evident in the case of small datasets. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. An Environmental Innovation: The Sewer Mouse

    NASA Technical Reports Server (NTRS)

    1979-01-01

    In the effort to clean up America's waters, there is a little-known complicating factor: because they leak, sewer systems in many American cities are causing rather than preventing pollution of rivers and lakes. Fixing the leaks is difficult because their locations are unknown. Maintenance crews can't tear up a whole city looking for cracks in the pipes; they must first determine which areas are most likely suspects. An aerospace spinoff is providing help in that regard. The problem starts with heavy rains. Rainwater naturally flows into the sewers from streets, but sewage systems are designed to accommodate it. However, they are not designed to handle the additional flow of "groundwater", rain absorbed by the earth which seeps into the sewers through leaks in pipes and sewer walls. After a storm, groundwater seepage can increase the waterflow to deluge proportions, with the result that sewage treatment plants are incapable of processing the swollen flow. When that happens the sluices must be opened, dumping raw sewage into rivers and lakes.

  17. Procurement Opportunitites in: Afghanistan and the Central Asian States (CAS)

    DTIC Science & Technology

    2012-08-01

    barriers) Furniture (office and household) Prefabricated Structures (CONEXs, containerized housing units, re-locatable buildings) Office Supplies... Concrete Foundation and Structure Road Support Activities Minor Building Renovation Water and Sewer Line and Related Construction Heavy and Civil

  18. REDUCED COST SEWER PIPE RELINING USING ULTRASONIC TAPE LAMINATION - PHASE I

    EPA Science Inventory

    Water and sewerage pipe rehabilitation represents a critical and expensive infrastructure issue. Although systems currently are available for relining existing pipes and constructing new lined pipes, the proposed advanced technology will improve the quality while substantia...

  19. Occurrence of organic wastewater-indicator compounds in urban streams of the Atlanta area, Georgia, 2003-2006

    USGS Publications Warehouse

    Lawrence, Stephen J.; LaFontaine, Jacob H.

    2010-01-01

    The similarity in the pattern and distribution of OWICs in samples at sites upstream and downstream from known CSO outfalls indicates that CSOs were not the dominant source of OWICs during the study period. Other sources may include non-sewage discharges-both permitted, permitted but out of compliance, and non-permitted, contaminated groundwater from leaking sewer lines or septic systems, sanitary-sewer overflows, or dry-weather runoff from outdoor water use. These OWICs may be better suited for identifying sewage-contaminated groundwater than sewage-contaminated surface water because groundwater is not typically affected by the OWICs that are more common in urban runoff.

  20. Comparison of conventional rule based flow control with control processes based on fuzzy logic in a combined sewer system.

    PubMed

    Klepiszewski, K; Schmitt, T G

    2002-01-01

    While conventional rule based, real time flow control of sewer systems is in common use, control systems based on fuzzy logic have been used only rarely, but successfully. The intention of this study is to compare a conventional rule based control of a combined sewer system with a fuzzy logic control by using hydrodynamic simulation. The objective of both control strategies is to reduce the combined sewer overflow volume by an optimization of the utilized storage capacities of four combined sewer overflow tanks. The control systems affect the outflow of four combined sewer overflow tanks depending on the water levels inside the structures. Both systems use an identical rule base. The developed control systems are tested and optimized for a single storm event which affects heterogeneously hydraulic load conditions and local discharge. Finally the efficiencies of the two different control systems are compared for two more storm events. The results indicate that the conventional rule based control and the fuzzy control similarly reach the objective of the control strategy. In spite of the higher expense to design the fuzzy control system its use provides no advantages in this case.

  1. Modelling sewer sediment deposition, erosion, and transport processes to predict acute influent and reduce combined sewer overflows and CO(2) emissions.

    PubMed

    Mouri, Goro; Oki, Taikan

    2010-01-01

    Understanding of solids deposition, erosion, and transport processes in sewer systems has improved considerably in the past decade. This has provided guidance for controlling sewer solids and associated acute pollutants to protect the environment and improve the operation of wastewater systems. Although measures to decrease combined sewer overflow (CSO) events have reduced the amount of discharged pollution, overflows continue to occur during rainy weather in combined sewer systems. The solution lies in the amount of water allotted to various processes in an effluent treatment system, in impact evaluation of water quality and prediction technology, and in stressing the importance of developing a control technology. Extremely contaminated inflow has been a serious research subject, especially in connection with the influence of rainy weather on nitrogen and organic matter removal efficiency in wastewater treatment plants (WWTP). An intensive investigation of an extremely polluted inflow load to WWTP during rainy weather was conducted in the city of Matsuyama, the region used for the present research on total suspended solid (TSS) concentration. Since the inflow during rainy weather can be as much as 400 times that in dry weather, almost all sewers are unsettled and overflowing when a rain event is more than moderate. Another concern is the energy consumed by wastewater treatment; this problem has become important from the viewpoint of reducing CO(2) emissions and overall costs. Therefore, while establishing a prediction technology for the inflow water quality characteristics of a sewage disposal plant is an important priority, the development of a management/control method for an effluent treatment system that minimises energy consumption and CO(2) emissions due to water disposal is also a pressing research topic with regards to the quality of treated water. The procedure to improve water quality must make use of not only water quality and biotic criteria, but also modelling systems to enable the user to link the effect of changes in urban sewage systems with specific quality, energy consumption, CO(2) emission, and ecological improvements of the receiving water.

  2. A novel approach to model dynamic flow interactions between storm sewer system and overland surface for different land covers in urban areas

    NASA Astrophysics Data System (ADS)

    Chang, Tsang-Jung; Wang, Chia-Ho; Chen, Albert S.

    2015-05-01

    In this study, we developed a novel approach to simulate dynamic flow interactions between storm sewers and overland surface for different land covers in urban areas. The proposed approach couples the one-dimensional (1D) sewer flow model (SFM) and the two-dimensional (2D) overland flow model (OFM) with different techniques depending on the land cover type of the study areas. For roads, pavements, plazas, and so forth where rainfall becomes surface runoff before entering the sewer system, the rainfall-runoff process is simulated directly in the 2D OFM, and the runoff is drained to the sewer network via inlets, which is regarded as the input to 1D SFM. For green areas on which rainfall falls into the permeable ground surface and the generated direct runoff traverses terrain, the deduction rate is applied to the rainfall for reflecting the soil infiltration in the 2D OFM. For flat building roofs with drainage facilities allowing rainfall to drain directly from the roof to sewer networks, the rainfall-runoff process is simulated using the hydrological module in the 1D SFM where no rainfall is applied to these areas in the 2D OFM. The 1D SFM is used for hydraulic simulations in the sewer network. Where the flow in the drainage network exceeds its capacity, a surcharge occurs and water may spill onto the ground surface if the pressure head in a manhole exceeds the ground elevation. The overflow discharge from the sewer system is calculated by the 1D SFM and considered a point source in the 2D OFM. The overland flow will return into the sewer network when it reaches an inlet that connects to an un-surcharged manhole. In this case, the inlet is considered as a point sink in the 2D OFM and an inflow to a manhole in the 1D SFM. The proposed approach was compared to other five urban flood modelling techniques with four rainfall events that had previously recorded inundation areas. The merits and drawbacks of each modelling technique were compared and discussed. Based on the simulated results, the proposed approach was found to simulate floodings closer to the survey records than other approaches because the physical rainfall-runoff phenomena in urban environment were better reflected.

  3. Technology Demonstration: Acoustic Condition Assessment of Wastewater Collection Systems

    EPA Science Inventory

    The overall objective of this EPA-funded study was to demonstrate innovative sewer line assessment technologies that are designed for rapid deployment using portable equipment. This study focused on demonstration of technologies that are suitable for smaller diameter pipes (less ...

  4. Rapid sonic characterisation of sewer change and obstructions.

    PubMed

    Podd, F J; Ali, M T B; Horoshenkov, K V; Wood, A S; Tait, S J; Boot, J C; Long, R; Saul, A J

    2007-01-01

    This paper reports on the development of a low-cost, rapidly deployable sensor for surveying live sewers for blockages and structural failures. The anticipated cost is an order of magnitude lower than current techniques. The technology is based on acoustic normal model decomposition, The instrument emits short coded acoustic signals which are reflected from any sewer wall defect. The acoustic signals can be short Gaussian pulses or longer sinusoidal sweeps and pseudo-random noise. The processing algorithms used on the reflected signal can predict the extent and geometry of the pipe deformation, and the locations and approximate size of common blockages. The effect of the water level on the frequency of the fundamental mode has also been investigated. It is shown that the technique can be adapted to work reliably in relatively large 600 mm diameter sewer pipes.

  5. Overview of Microbial Source Tracking Methods Targeting Human Fecal Pollution Sources

    EPA Science Inventory

    Exposure to human fecal waste can be a public health risk dueto the presence of human pathogens. Human fecal pollutioncan be introduced into water resources from damagedsewer lines, faulty septic systems, combined sewer overflows,illicit dumping activities, and even recreational ...

  6. 25 CFR 700.453 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... normally found in a community and includes but is not limited to water, sewer and electrical lines, community centers, health centers and clinics, roads, and business establishments. (i) Services means activities relating to human development including, but not limited to, educational and job training, mental...

  7. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...

  8. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...

  9. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...

  10. Simulating groundwater-induced sewer flooding

    NASA Astrophysics Data System (ADS)

    Mijic, A.; Mansour, M.; Stanic, M.; Jackson, C. R.

    2016-12-01

    During the last decade, Chalk catchments of southern England experienced severe groundwater flooding. High groundwater levels resulted in the groundwater ingress into the sewer network that led to restricted toilet use and the overflow of diluted, but untreated sewage to road surfaces, rivers and water courses. In response to these events the water and sewerage company Thames Water Utilities Ltd (TWUL) had to allocate significant funds to mitigate the impacts. It was estimated that approximately £19m was spent responding to the extreme wet weather of 2013-14, along with the use of a fleet of over 100 tankers. However, the magnitude of the event was so large that these efforts could not stop the discharge of sewage to the environment. This work presents the analysis of the risk of groundwater-induced sewer flooding within the Chalk catchment of the River Lambourn, Berkshire. A spatially distributed groundwater model was used to assess historic groundwater flood risk and the potential impacts of changes in future climate. We then linked this model to an urban groundwater model to enable us to simulate groundwater-sewer interaction in detail. The modelling setup was used to identify relationships between infiltration into sewers and groundwater levels at specific points on TWUL's sewer network, and to estimate historic and future groundwater flood risk, and how this varies across the catchment. The study showed the significance of understanding the impact of groundwater on the urban water systems, and producing information that can inform a water company's response to groundwater flood risk, their decision making process and their asset management planning. However, the knowledge gained through integrated modelling of groundwater-sewer interactions has highlighted limitations of existing approaches for the simulation of these coupled systems. We conclude this work with number of recommendations about how to improve such hydrological/sewer analysis.

  11. Impact of reduced water consumption on sulfide and methane production in rising main sewers.

    PubMed

    Sun, Jing; Hu, Shihu; Sharma, Keshab Raj; Bustamante, Heriberto; Yuan, Zhiguo

    2015-05-01

    Reduced water consumption (RWC), for water conservation purposes, is expected to change the wastewater composition and flow conditions in sewer networks and affect the in-sewer transformation processes. In this study, the impact of reduced water consumption on sulfide and methane production in rising main sewers was investigated. Two lab-scale rising main sewer systems fed with wastewater of different strength and flow rates were operated to mimic sewers under normal and RWC conditions (water consumption reduced by 40%). Sulfide concentration under the RWC condition increased by 0.7-8.0 mg-S/L, depending on the time of a day. Batch test results showed that the RWC did not change the sulfate-reducing activity of sewer biofilms, the increased sulfide production being mainly due to longer hydraulic retention time (HRT). pH in the RWC system was about 0.2 units lower than that in the normal system, indicating that more sulfide would be in molecular form under the RWC condition, which would result in increased sulfide emission to the atmosphere as confirmed by the model simulation. Model based analysis showed that the cost for chemical dosage for sulfide mitigation would increase significantly per unit volume of sewage, although the total cost would decrease due to a lower sewage flow. The dissolved methane concentration under the RWC condition was over two times higher than that under the normal flow condition and the total methane discharge was about 1.5 times higher, which would potentially result in higher greenhouse gas emissions. Batch tests showed that the methanogenic activity of sewer biofilms increased under the RWC condition, which along with the longer HRT, led to increased methane production. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Sediment transport modeling in deposited bed sewers: unified form of May's equations using the particle swarm optimization algorithm.

    PubMed

    Safari, Mir Jafar Sadegh; Shirzad, Akbar; Mohammadi, Mirali

    2017-08-01

    May proposed two dimensionless parameters of transport (η) and mobility (F s ) for self-cleansing design of sewers with deposited bed condition. The relationships between those two parameters were introduced in conditional form for specific ranges of F s , which makes it difficult to use as a practical tool for sewer design. In this study, using the same experimental data used by May and employing the particle swarm optimization algorithm, a unified equation is recommended based on η and F s . The developed model is compared with original May relationships as well as corresponding models available in the literature. A large amount of data taken from the literature is used for the models' evaluation. The results demonstrate that the developed model in this study is superior to May and other existing models in the literature. Due to the fact that in May's dimensionless parameters more effective variables in the sediment transport process in sewers with deposited bed condition are considered, it is concluded that the revised May equation proposed in this study is a reliable model for sewer design.

  13. Temporal asymmetry in precipitation time series and its influence on flow simulations in combined sewer systems

    NASA Astrophysics Data System (ADS)

    Müller, Thomas; Schütze, Manfred; Bárdossy, András

    2017-09-01

    A property of natural processes is temporal irreversibility. However, this property cannot be reflected by most statistics used to describe precipitation time series and, consequently, is not considered in most precipitation models. In this paper, a new statistic, the asymmetry measure, is introduced and applied to precipitation enabling to detect and quantify irreversibility. It is used to analyze two different data sets of Singapore and Germany. The data of both locations show a significant asymmetry for high temporal resolutions. The asymmetry is more pronounced for Singapore where the climate is dominated by convective precipitation events. The impact of irreversibility on applications is analyzed on two different hydrological sewer system models. The results show that the effect of the irreversibility can lead to biases in combined sewer overflow statistics. This bias is in the same order as the effect that can be achieved by real time control of sewer systems. Consequently, wrong conclusion can be drawn if synthetic time series are used for sewer systems if asymmetry is present, but not considered in precipitation modeling.

  14. Research note: Mapping spatial patterns in sewer age, material, and proximity to surface waterways to infer sewer leakage hotspots

    USGS Publications Warehouse

    Hopkins, Kristina G.; Bain, Daniel J.

    2018-01-01

    Identifying areas where deteriorating sewer infrastructure is in close proximity to surface waterways is needed to map likely connections between sewers and streams. We present a method to estimate sewer installation year and deterioration status using historical maps of the sewer network, parcel-scale property assessment data, and pipe material. Areas where streams were likely buried into the sewer system were mapped by intersecting the historical stream network derived from a 10-m resolution digital elevation model with sewer pipe locations. Potential sewer leakage hotspots were mapped by identifying where aging sewer pipes are in close proximity (50-m) to surface waterways. Results from Pittsburgh, Pennsylvania (USA), indicated 41% of the historical stream length was lost or buried and the potential interface between sewers and streams is great. The co-location of aging sewer infrastructure (>75 years old) near stream channels suggests that 42% of existing streams are located in areas with a high potential for sewer leakage if sewer infrastructure fails. Mapping the sewer-stream interface provides an approach to better understand areas were failing sewers may contribute a disproportional amount of nutrients and other pathogens to surface waterways.

  15. U.S. EPA Technology Demonstration: Acoustic Condition Assessment of Wastewater Collection Systems

    EPA Science Inventory

    The overall objective of this EPA-funded study was to demonstrate innovative sewer line assessment technologies that are designed for rapid deployment using portable equipment. This study focused on demonstration of technologies that are suitable for smaller diameter pipes (less ...

  16. COMBINED SEWER OVERFLOW - BALANCING FLOW FOR CSO ABATEMENT

    EPA Science Inventory

    Instead of using conventional storage units, e.g., reinforced concrete tanks and lined earthen basins, which are relatively expensive and require a lot of urban land area, the in-receiving water flow balance method (FBM) facilities use the receiving water body itself for storage ...

  17. 40 CFR 60.691 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... collection point for stormwater runoff received directly from refinery surfaces and for refinery wastewater... chamber in a stationary manner and which does not move with fluctuations in wastewater levels. Floating... separator. Junction box means a manhole or access point to a wastewater sewer system line. No detectable...

  18. Stochastic modeling of total suspended solids (TSS) in urban areas during rain events.

    PubMed

    Rossi, Luca; Krejci, Vladimir; Rauch, Wolfgang; Kreikenbaum, Simon; Fankhauser, Rolf; Gujer, Willi

    2005-10-01

    The load of total suspended solids (TSS) is one of the most important parameters for evaluating wet-weather pollution in urban sanitation systems. In fact, pollutants such as heavy metals, polycyclic aromatic hydrocarbons (PAHs), phosphorous and organic compounds are adsorbed onto these particles so that a high TSS load indicates the potential impact on the receiving waters. In this paper, a stochastic model is proposed to estimate the TSS load and its dynamics during rain events. Information on the various simulated processes was extracted from different studies of TSS in urban areas. The model thus predicts the probability of TSS loads arising from combined sewer overflows (CSOs) in combined sewer systems as well as from stormwater in separate sewer systems in addition to the amount of TSS retained in treatment devices in both sewer systems. The results of this TSS model illustrate the potential of the stochastic modeling approach for assessing environmental problems.

  19. Estimation of radiocesium dietary intake from time series data of radiocesium concentrations in sewer sludge.

    PubMed

    Pratama, Mochamad Adhiraga; Takahara, Shogo; Munakata, Masahiro; Yoneda, Minoru

    2018-06-01

    After the Fukushima accident, it became important to determine the quantity of radionuclide ingested by inhabitants. The most common methods currently used to obtain such data are the "market basket" (MB) and "duplicate" (DP) methods. However, it is difficult to conduct monitorings using these methods with sufficient frequency as they are high cost and time-consuming. The present study proposes a new method to estimate the ingestion of radionuclides, based on the time-dependent concentrations of radiocesium in sewer sludge, which addresses the uncertainties of the two common methods. The newly proposed method, which we designate as SL, consists of three steps: (1) the separation of wet weather and dry weather data, (2) determining the mass balance of the wastewater treatment plant (WWTP), and (3) developing a reverse biokinetic model to relate the amount of radionuclides ingested to the amounts contained in the sewer sludge. We tested the new method using the time-dependent radiocesium concentrations in sewer sludge from the WWTP in Fukushima City. The results from the SL method agreed to those from the MB while overestimated those from DP method. The trend lines for all three methods, however, are in good agreement. Sensitivity analyses of SL method indicate further studies on uncertainties of sensitive parameters are deemed necessary to improve the accuracy of the method. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other junction boxes (e.g., manholes, sumps, and lift stations) conveying regulated-material. For the purpose of... segregated from all other individual drain systems. Junction box means a sump, manhole, or access point to a...

  1. 40 CFR 261.3 - Definition of hazardous waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... discharged to the refinery oil recovery sewer before primary oil/water/solids separation—heat exchanger bundle cleaning sludge from the petroleum refining industry (EPA Hazardous Waste No. K050), crude oil... oil tank sediment and/or in-line filter/separation solids from petroleum refining operations (EPA...

  2. 40 CFR 261.3 - Definition of hazardous waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... discharged to the refinery oil recovery sewer before primary oil/water/solids separation—heat exchanger bundle cleaning sludge from the petroleum refining industry (EPA Hazardous Waste No. K050), crude oil... oil tank sediment and/or in-line filter/separation solids from petroleum refining operations (EPA...

  3. 40 CFR 261.3 - Definition of hazardous waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... discharged to the refinery oil recovery sewer before primary oil/water/solids separation—heat exchanger bundle cleaning sludge from the petroleum refining industry (EPA Hazardous Waste No. K050), crude oil... oil tank sediment and/or in-line filter/separation solids from petroleum refining operations (EPA...

  4. Wastewater-Enhanced Microbial Corrosion of Concrete Sewers.

    PubMed

    Jiang, Guangming; Zhou, Mi; Chiu, Tsz Ho; Sun, Xiaoyan; Keller, Jurg; Bond, Philip L

    2016-08-02

    Microbial corrosion of concrete in sewers is known to be caused by hydrogen sulfide, although the role of wastewater in regulating the corrosion processes is poorly understood. Flooding and splashing of wastewater in sewers periodically inoculates the concrete surface in sewer pipes. No study has systematically investigated the impacts of wastewater inoculation on the corrosion of concrete in sewers. This study investigated the development of the microbial community, sulfide uptake activity, and the change of the concrete properties for coupons subjected to periodic wastewater inoculation. The concrete coupons were exposed to different levels of hydrogen sulfide under well-controlled conditions in laboratory-scale corrosion chambers simulating real sewers. It was evident that the periodic inoculation induced higher corrosion losses of the concrete in comparison to noninoculated coupons. Instantaneous measurements such as surface pH did not reflect the cumulative corrosion losses caused by long-term microbial activity. Analysis of the long-term profiles of the sulfide uptake rate using a Gompertz model supported the enhanced corrosion activity and greater corrosion loss. The enhanced corrosion rate was due to the higher sulfide uptake rates induced by wastewater inoculation, although the increasing trend of sulfide uptake rates was slower with wastewater. Increased diversity in the corrosion-layer microbial communities was detected when the corrosion rates were higher. This coincided with the environmental conditions of increased levels of gaseous H2S and the concrete type.

  5. 40 CFR 280.51 - Investigation due to off-site impacts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Investigation due to off-site impacts. 280.51 Section 280.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID... vapors in soils, basements, sewer and utility lines, and nearby surface and drinking waters) that has...

  6. Frost-Shielding Methodology and Demonstration for Shallow Burial of Water and Sewer Utility Lines.

    DTIC Science & Technology

    1998-06-01

    Research and Engineering Laboratory (CRREL), and the Owens - Corning Specialty and Foam Products Division as partners. Test sites utilizing shielded pipes...predictions and provided valuable guidance for the frost shield design. The industry partner participant in the CPAR project, Owens - Corning Specialty and Foam

  7. 40 CFR 63.964 - Inspection and monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Defects include, but are not limited to, visible cracks, holes, or gaps in the closure devices; broken..., visible cracks, holes, or gaps in the closure devices; broken, cracked, or otherwise damaged seals or..., visible cracks, holes, gaps, or other open spaces in the sewer line joints, seals, or other emission...

  8. 40 CFR 63.964 - Inspection and monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Defects include, but are not limited to, visible cracks, holes, or gaps in the closure devices; broken..., visible cracks, holes, or gaps in the closure devices; broken, cracked, or otherwise damaged seals or..., visible cracks, holes, gaps, or other open spaces in the sewer line joints, seals, or other emission...

  9. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    PubMed Central

    Su, Tung-Ching; Yang, Ming-Der

    2014-01-01

    As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically idengified through closed circuit television (CCTV) inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED), to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO) and closing bottom-hat operation (CBHO), were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines. PMID:24841247

  10. Fault detection on a sewer network by a combination of a Kalman filter and a binary sequential probability ratio test

    NASA Astrophysics Data System (ADS)

    Piatyszek, E.; Voignier, P.; Graillot, D.

    2000-05-01

    One of the aims of sewer networks is the protection of population against floods and the reduction of pollution rejected to the receiving water during rainy events. To meet these goals, managers have to equip the sewer networks with and to set up real-time control systems. Unfortunately, a component fault (leading to intolerable behaviour of the system) or sensor fault (deteriorating the process view and disturbing the local automatism) makes the sewer network supervision delicate. In order to ensure an adequate flow management during rainy events it is essential to set up procedures capable of detecting and diagnosing these anomalies. This article introduces a real-time fault detection method, applicable to sewer networks, for the follow-up of rainy events. This method consists in comparing the sensor response with a forecast of this response. This forecast is provided by a model and more precisely by a state estimator: a Kalman filter. This Kalman filter provides not only a flow estimate but also an entity called 'innovation'. In order to detect abnormal operations within the network, this innovation is analysed with the binary sequential probability ratio test of Wald. Moreover, by crossing available information on several nodes of the network, a diagnosis of the detected anomalies is carried out. This method provided encouraging results during the analysis of several rains, on the sewer network of Seine-Saint-Denis County, France.

  11. COMBINED-SEWER OVERFLOW CONTROL AND TREATMENT

    EPA Science Inventory

    Combined-sewer overflow (CSO), along with sanitary-sewer overflow and stormwater are significant contributors of contamination to surface waters. During a rain event, the flow in a combined sewer system may exceed the capacity of the intercepting sewer leading to the wastewater t...

  12. Selective inspection planning with ageing forecast for sewer types.

    PubMed

    Baur, R; Herz, R

    2002-01-01

    Investments in sewer rehabilitation must be based on inspection and evaluation of sewer conditions with respect to the severity of sewer damage and to environmental risks. This paper deals with the problems of forecasting the condition of sewers in a network from a small sample of inspected sewers. Transition functions from one into the next poorer condition class, which were empirically derived from this sample, are used to forecast the condition of sewers. By the same procedure, transition functions were subsequently calibrated for sub-samples of different types of sewers. With these transition functions, the most probable date of entering a critical condition class can be forecast from sewer characteristics, such as material, period of construction, location, use for waste and/or storm water, profile, diameter and gradient. Results are shown for the estimates about the actual condition of the Dresden sewer network and its deterioration in case of doing nothing about it. A procedure is proposed for scheduling the inspection dates for sewers which have not yet been inspected and for those which have been inspected before.

  13. Environmental Assessment for Renovation and Small Addition for AGE Facility MacDill AFB, Florida

    DTIC Science & Technology

    2005-05-01

    one lift station, all of the sanitary sewer lines have, in essence , at least one check valve to stop the inflow of floodwater to the WWTP. The...Force Base Installation Restoration Program 7621 Hillsborough Loop Dr. MacDill AFB, FL 33621-5207 Jasmine Raffington FL Coastal Management

  14. 40 CFR 280.50 - Reporting of suspected releases.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., the sudden loss of product from the UST system, or an unexplained presence of water in the tank... vapors in soils, basements, sewer and utility lines, and nearby surface water). (b) Unusual operating...; or (2) In the case of inventory control, a second month of data does not confirm the initial result. ...

  15. 78 FR 4165 - Notice of Availability of the Draft Environmental Impact Statement for the Arturo Mine Project...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-18

    ... office, substation and associated power transmission lines, water wells, water distribution and sewer...; access; discharges to surface water; air quality (including mercury); and impacts to stream drainages... which may impact water resources, and the Elko County Board of Commissioners have raised concerns about...

  16. PLANNING FOR SSO CONTROL: HENRICO COUNTY, VA - CASE STUDY

    EPA Science Inventory

    The nation's sanitary-sewer infrastructure is aging with some sewers over 100 years. There are more than 19,500 municipal sanitary-sewer collecton systems nationwide serving 150M people comprising 500,000 sewer miles. About 40,000 sanitary-sewer overflow (SSO) events nationwide y...

  17. Rain events and their effect on effluent quality studied at a full scale activated sludge treatment plant.

    PubMed

    Wilén, B M; Lumley, D; Mattsson, A; Mino, T

    2006-01-01

    The effect of rain events on effluent quality dynamics was studied at a full scale activated sludge wastewater treatment plant which has a process solution incorporating pre-denitrification in activated sludge with post-nitrification in trickling filters. The incoming wastewater flow varies significantly due to a combined sewer system. Changed flow conditions have an impact on the whole treatment process since the recirculation to the trickling filters is set by the hydraulic limitations of the secondary settlers. Apart from causing different hydraulic conditions in the plant, increased flow due to rain or snow-melting, changes the properties of the incoming wastewater which affects process performance and effluent quality, especially the particle removal efficiency. A comprehensive set of on-line and laboratory data were collected and analysed to assess the impact of rain events on the plant performance.

  18. From mess to mass: a methodology for calculating storm event pollutant loads with their uncertainties, from continuous raw data time series.

    PubMed

    Métadier, M; Bertrand-Krajewski, J-L

    2011-01-01

    With the increasing implementation of continuous monitoring of both discharge and water quality in sewer systems, large data bases are now available. In order to manage large amounts of data and calculate various variables and indicators of interest it is necessary to apply automated methods for data processing. This paper deals with the processing of short time step turbidity time series to estimate TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) event loads in sewer systems during storm events and their associated uncertainties. The following steps are described: (i) sensor calibration, (ii) estimation of data uncertainties, (iii) correction of raw data, (iv) data pre-validation tests, (v) final validation, and (vi) calculation of TSS and COD event loads and estimation of their uncertainties. These steps have been implemented in an integrated software tool. Examples of results are given for a set of 33 storm events monitored in a stormwater separate sewer system.

  19. Development of a semi-automated model identification and calibration tool for conceptual modelling of sewer systems.

    PubMed

    Wolfs, Vincent; Villazon, Mauricio Florencio; Willems, Patrick

    2013-01-01

    Applications such as real-time control, uncertainty analysis and optimization require an extensive number of model iterations. Full hydrodynamic sewer models are not sufficient for these applications due to the excessive computation time. Simplifications are consequently required. A lumped conceptual modelling approach results in a much faster calculation. The process of identifying and calibrating the conceptual model structure could, however, be time-consuming. Moreover, many conceptual models lack accuracy, or do not account for backwater effects. To overcome these problems, a modelling methodology was developed which is suited for semi-automatic calibration. The methodology is tested for the sewer system of the city of Geel in the Grote Nete river basin in Belgium, using both synthetic design storm events and long time series of rainfall input. A MATLAB/Simulink(®) tool was developed to guide the modeller through the step-wise model construction, reducing significantly the time required for the conceptual modelling process.

  20. Advances in Sewer Condition and Capacity Assessment – Development and Applications of EPA SSOAP Toolbox

    EPA Science Inventory

    In the United States, sanitary sewer infrastructure is aging, with some sewers dating back over 100 years. Nationwide, there are more than 19,500 municipal sanitary-sewer collection systems serving an estimated 150 million people and about 40,000 sanitary sewer overflow (SSO) ev...

  1. U.S. EPA Issues Technical Guides and Computer Tools for Sewer Condition and Capacity Assessment

    EPA Science Inventory

    The nation's sanitary sewer infrastructure is aging, with some sewers more than100 years old. Nationwide, there are more than 19,500 municipal sanitary-sewer collection systems serving an estimated 150 million people and about 40,000 sanitary sewer overflow (SSO) events per year...

  2. A model for methane production in sewers.

    PubMed

    Chaosakul, Thitirat; Koottatep, Thammarat; Polprasert, Chongrak

    2014-09-19

    Most sewers in developing countries are combined sewers which receive stormwater and effluent from septic tanks or cesspools of households and buildings. Although the wastewater strength in these sewers is usually lower than those in developed countries, due to improper construction and maintenance, the hydraulic retention time (HRT) could be relatively long and resulting considerable greenhouse gas (GHG) production. This study proposed an empirical model to predict the quantity of methane production in gravity-flow sewers based on relevant parameters such as surface area to volume ratio (A/V) of sewer, hydraulic retention time (HRT) and wastewater temperature. The model was developed from field survey data of gravity-flow sewers located in a peri-urban area, central Thailand and validated with field data of a sewer system of the Gold Coast area, Queensland, Australia. Application of this model to improve construction and maintenance of gravity-flow sewers to minimize GHG production and reduce global warming is presented.

  3. 40 CFR 35.927-2 - Sewer system evaluation survey.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Sewer system evaluation survey. 35.927... § 35.927-2 Sewer system evaluation survey. (a) The sewer system evaluation survey shall identify the... results of the sewer system evaluation survey. In addition, the report shall include: (1) A justification...

  4. 40 CFR 35.927-2 - Sewer system evaluation survey.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Sewer system evaluation survey. 35.927... § 35.927-2 Sewer system evaluation survey. (a) The sewer system evaluation survey shall identify the... results of the sewer system evaluation survey. In addition, the report shall include: (1) A justification...

  5. 40 CFR 35.927-2 - Sewer system evaluation survey.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Sewer system evaluation survey. 35.927... § 35.927-2 Sewer system evaluation survey. (a) The sewer system evaluation survey shall identify the... results of the sewer system evaluation survey. In addition, the report shall include: (1) A justification...

  6. 40 CFR 35.927-2 - Sewer system evaluation survey.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Sewer system evaluation survey. 35.927... § 35.927-2 Sewer system evaluation survey. (a) The sewer system evaluation survey shall identify the... results of the sewer system evaluation survey. In addition, the report shall include: (1) A justification...

  7. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing.

    PubMed

    Schilperoort, Rémy; Hoppe, Holger; de Haan, Cornelis; Langeveld, Jeroen

    2013-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.

  8. Locations of Combined Sewer Overflow Outfalls - US EPA Region 3

    EPA Pesticide Factsheets

    This data layer identifies the locations of Combined sewer overflow outfalls. Combined sewer systems are sewers that are designed to collect rainwater runoff, domestic sewage, and industrial wastewater in the same pipe. Most of the time, combined sewer systems transport all of their wastewater to a sewage treatment plant, where it is treated and then discharged to a water body. During periods of heavy rainfall or snowmelt, however, the wastewater volume in a combined sewer system can exceed the capacity of the sewer system or treatment plant. For this reason, combined sewer systems are designed to overflow occasionally and discharge excess untreated wastewater directly to nearby streams, rivers, or other water bodies. For further information visit: http://cfpub1.epa.gov/npdes/home.cfm?program_id=5

  9. Infiltration and hydraulic connections from the Niagara River to a fractured-dolomite aquifer in Niagara Falls, New York

    USGS Publications Warehouse

    Yager, R.M.; Kappel, W.M.

    1998-01-01

    The spatial distribution of hydrogen and oxygen stable-isotope values in groundwater can be used to distinguish different sources of recharge and to trace groundwater flow directions from recharge boundaries. This method can be particularly useful in fractured-rock settings where multiple lines of evidence are required to delineate preferential flow paths that result from heterogeneity within fracture zones. Flow paths delineated with stable isotopes can be combined with hydraulic data to form a more complete picture of the groundwater flow system. In this study values of ??D and ??18O were used to delineate paths of river-water infiltration into the Lockport Group, a fractured dolomite aquifer, and to compute the percentage of fiver water in groundwater samples from shallow bedrock wells. Flow paths were correlated with areas of high hydraulic diffusivity in the shallow bedrock that were delineated from water-level fluctuations induced by diurnal stage fluctuations in man-made hydraulic structures. Flow paths delineated with the stable-isotope and hydraulic data suggest that fiver infiltration reaches an unlined storm sewer in the bedrock through a drainage system that surrounds aqueducts carrying river water to hydroelectric power plants. This finding is significant because the storm sewer is the discharge point for contaminated groundwater from several chemical waste-disposal sites and the cost of treating the storm sewer's discharge could be reduced if the volume of infiltration from the river were decreased.The spatial distribution of hydrogen and oxygen stable-isotope values in groundwater can be used to distinguish different sources of recharge and to trace groundwater flow directions from recharge boundaries. This method can be particularly useful in fractured-rock settings where multiple lines of evidence are required to delineate preferential flow paths that result from heterogeneity within fracture zones. Flow paths delineated with stable isotopes can be combined with hydraulic data to form a more complete picture of the groundwater flow system. In this study values of ??D and ??18O were used to delineate paths of river-water infiltration into the Lockport Group, a fractured dolomite aquifer, and to compute the percentage of river water in groundwater samples from shallow bedrock wells. Flow paths were correlated with areas of high hydraulic diffusivity in the shallow bedrock that were delineated from water-level fluctuations induced by diurnal stage fluctuations in man-made hydraulic structures. Flow paths delineated with the stable-isotope and hydraulic data suggest that river infiltration reaches an unlined storm sewer in the bedrock through a drainage system that surrounds aqueducts carrying river water to hydroelectric power plants. This finding is significant because the storm sewer is the discharge point for contaminated groundwater from several chemical waste-disposal sites and the cost of treating the storm sewer's discharge could be reduced if the volume of infiltration from the river were decreased.

  10. Impact of toxic chemicals on local wastewater treatment plant and the environment

    NASA Astrophysics Data System (ADS)

    Bennett, Gary F.

    1989-05-01

    Because toxic chemicals being discharged to sewers were simultaneously interfering with wastewater treatment processes of municipal, biological treatment plants and were passing through these plants to negatively impact the bodies of water to which these plants were discharging, the U.S. Environmental Protection Agency issued regulations governing industrial discharges to municipal sewers. These “Pretreatment Regulations” limit industrial discharges to municipal sewers of heavy metals, oil and grease, acids and bases, and toxic organic chemicals. This paper discusses the evolution of these regulations, the basis for them, the types of regulations (categorical and local), and the rationale for their promulgation based on the impacts of toxics chemicals on the treatment plant and receiving system. Finally, the expected results of these regulations in reducing industrial discharges of toxic chemicals is discussed.

  11. Biodegradability of organic matter associated with sewer sediments during first flush.

    PubMed

    Sakrabani, Ruben; Vollertsen, Jes; Ashley, Richard M; Hvitved-Jacobsen, Thorkild

    2009-04-01

    The high pollution load in wastewater at the beginning of a rain event is commonly known to originate from the erosion of sewer sediments due to the increased flow rate under storm weather conditions. It is essential to characterize the biodegradability of organic matter during a storm event in order to quantify the effect it can have further downstream to the receiving water via discharges from Combined Sewer Overflow (CSO). The approach is to characterize the pollutograph during first flush. The pollutograph shows the variation in COD and TSS during a first flush event. These parameters measure the quantity of organic matter present. However these parameters do not indicate detailed information on the biodegradability of the organic matter. Such detailed knowledge can be obtained by dividing the total COD into fractions with different microbial properties. To do so oxygen uptake rate (OUR) measurements on batches of wastewater have shown itself to be a versatile technique. Together with a conceptual understanding of the microbial transformation taking place, OUR measurements lead to the desired fractionation of the COD. OUR results indicated that the highest biodegradability is associated with the initial part of a storm event. The information on physical and biological processes in the sewer can be used to better manage sediment in sewers which can otherwise result in depletion of dissolved oxygen in receiving waters via discharges from CSOs.

  12. Vapor Intrusion from Entrapped NAPL Sources and Groundwater Plumes: Process Understanding and Improved Modeling Tools for Pathway Assessment

    DTIC Science & Technology

    2014-07-01

    into a building ....149 Figure 5.52: Effect of infiltration at 1 mm/hr for 24 hours on vapor signals in sandy clay loam scenario...shown above, there will also likely be large diameter sanitary sewers running the length of each street. Each house on the street will have a sewer...permeability, a discontinuous clay layer system, and a system with scattered obstacles (e.g. utilities). The layered systems indicated that the sequence of

  13. Effect of inlet modelling on surface drainage in coupled urban flood simulation

    NASA Astrophysics Data System (ADS)

    Jang, Jiun-Huei; Chang, Tien-Hao; Chen, Wei-Bo

    2018-07-01

    For a highly developed urban area with complete drainage systems, flood simulation is necessary for describing the flow dynamics from rainfall, to surface runoff, and to sewer flow. In this study, a coupled flood model based on diffusion wave equations was proposed to simulate one-dimensional sewer flow and two-dimensional overland flow simultaneously. The overland flow model provides details on the rainfall-runoff process to estimate the excess runoff that enters the sewer system through street inlets for sewer flow routing. Three types of inlet modelling are considered in this study, including the manhole-based approach that ignores the street inlets by draining surface water directly into manholes, the inlet-manhole approach that drains surface water into manholes that are each connected to multiple inlets, and the inlet-node approach that drains surface water into sewer nodes that are connected to individual inlets. The simulation results were compared with a high-intensity rainstorm event that occurred in 2015 in Taipei City. In the verification of the maximum flood extent, the two approaches that considered street inlets performed considerably better than that without street inlets. When considering the aforementioned models in terms of temporal flood variation, using manholes as receivers leads to an overall inefficient draining of the surface water either by the manhole-based approach or by the inlet-manhole approach. Using the inlet-node approach is more reasonable than using the inlet-manhole approach because the inlet-node approach greatly reduces the fluctuation of the sewer water level. The inlet-node approach is more efficient in draining surface water by reducing flood volume by 13% compared with the inlet-manhole approach and by 41% compared with the manhole-based approach. The results show that inlet modeling has a strong influence on drainage efficiency in coupled flood simulation.

  14. Development of a household waste treatment subsystem, volume 1. [with water conservation features

    NASA Technical Reports Server (NTRS)

    Gresko, T. M.; Murray, R. W.

    1973-01-01

    The domestic waste treatment subsystem was developed to process the daily liquid and non-metallic solid wastes provided by a family of four people. The subsystem was designed to be connected to the sewer line of a household which contained water conservation features. The system consisted of an evaporation technique to separate liquids from solids, an incineration technique for solids reduction, and a catalytic oxidizer for eliminating noxious gases from evaporation and incineration processes. All wastes were passed through a grinder which masticated the solids and deposited them in a settling tank. The liquids were transferred through a cleanable filter into a holding tank. From here the liquids were sprayed into an evaporator and a spray chamber where evaporation occurred. The resulting vapors were processed by catalytic oxidation. Water and latent energy were recovered in a combination evaporator/condenser heat exchanger. The solids were conveyed into an incinerator and reduced to ash while the incineration gases were passed through the catalytic oxidizer along with the processed water vapor.

  15. USEPA CAPSTONE REPORT: CONTROL AND TREATMENT

    EPA Science Inventory

    Combined-sewer overflows (CSOs), sanitary-sewer overflows and stormwater (SW) are significant contributors of contamination to surface waters. During a rain event, the flow in a combined sewer system may exceed the capacity of the intercepting sewer leading to the wastewater trea...

  16. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    EPA Science Inventory

    This presentation overviews causes of sewer deterioration and heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer- and combined sewer overflow- (CSO-) storage-tank-flushing systems for removal of ...

  17. SANITARY SEWER OVERFLOW ANALYSIS AND PLANNING (SSOAP) TOOLBOX

    EPA Science Inventory

    Description: The Nation's sanitary-sewer infrastructure is aging, with some sewers dating back over 100 years. Nationwide, there are more than 19,500 municipal sanitary-sewer collection systems serving an estimated 150 million people and about 40,000 SSO events per year. Becau...

  18. EPA SSOAP Toolbox – Evolution and Applications

    EPA Science Inventory

    The nation’s sanitary sewer infrastructure is aging, with some sewers dating back more than 100 years. Nationwide, there are more than 19,500 municipal sanitary-sewer collection systems serving an estimated 150 million people and about 40,000 sanitary sewer overflow (SSO) ...

  19. Measuring Flow Reductions in a Combined Sewer System using Green Infrastructure - abstract

    EPA Science Inventory

    In 2009, the Louisville and Jefferson County Metropolitan Sewer District (MSD) submitted an Integrated Overflow Abatement Plan (IOAP) addressing combined sewer overflows (CSOs) and sanitary sewer overflows. Many of the solutions involve gray infrastructure, such as large, end-of...

  20. SEWER SEDIMENT AND CONTROL: A MANAGEMENT PRACTICES REFERENCES GUIDE

    EPA Science Inventory

    Sewer-solids sediment is one of major sources of pollutants in urban wet-weather flow (WWF) discharges that include combined-sewer overflow (CSO), separate sanitary-sewer overflow (SSO), and stormwater runoff. During low-flow, dry-weather periods, sanitary wastewater solids depo...

  1. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    EPA Science Inventory

    This paper overviews causes of combined-sewer deterioration and their heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer and combined-sewer overflow (CSO) storage-tank-flushing systems for removi...

  2. Methane emission from sewers.

    PubMed

    Liu, Yiwen; Ni, Bing-Jie; Sharma, Keshab R; Yuan, Zhiguo

    2015-08-15

    Recent studies have shown that sewer systems produce and emit a significant amount of methane. Methanogens produce methane under anaerobic conditions in sewer biofilms and sediments, and the stratification of methanogens and sulfate-reducing bacteria may explain the simultaneous production of methane and sulfide in sewers. No significant methane sinks or methanotrophic activities have been identified in sewers to date. Therefore, most of the methane would be emitted at the interface between sewage and atmosphere in gravity sewers, pumping stations, and inlets of wastewater treatment plants, although oxidation of methane in the aeration basin of a wastewater treatment plant has been reported recently. Online measurements have also revealed highly dynamic temporal and spatial variations in methane production caused by factors such as hydraulic retention time, area-to-volume ratio, temperature, and concentration of organic matter in sewage. Both mechanistic and empirical models have been proposed to predict methane production in sewers. Due to the sensitivity of methanogens to environmental conditions, most of the chemicals effective in controlling sulfide in sewers also suppress or diminish methane production. In this paper, we review the recent studies on methane emission from sewers, including the production mechanisms, quantification, modeling, and mitigation. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. PLANNING FOR SSO CONTROL: HENRICO COUNTY, VA - CASE STUDY

    EPA Science Inventory

    The Nation's sanitary-sewer infrastructure is aging with some sewers dating back over 100 years. There are more than 19,500 municipal sanitary-sewer collection systems nationwide serving an estimated 150M people and comprising about 500,000 sewer miles. It is estimated that there...

  4. COMPUTER MODEL ANALYSIS FOR CONTROL PLANNING OF SANITARY-SEWER OVERFLOWS

    EPA Science Inventory

    The Nation's sanitary-sewer infrastructure is aging with some sewers dating back over 100 years. There are more than 19,500 municipal sanitary-sewer collection systems nationwide serving an estimated 150 million people and comprising about 800,000 km (500,000 mi) of municipally ...

  5. HANDBOOK: SEWER SYSTEM INFRASTRUCTURE ANALYSIS AND REHABILITATION

    EPA Science Inventory

    Many of our Nation's sewer systems date back to the 19th Century when brick sewers were common. hese and more recent sewer systems can be expected to fail in time, but because they are placed underground, signs of accelerated deterioration and capacity limitations are not readily...

  6. EPA SSOAP Toolbox Application for Condition and Capacity Assessment of Wastewater Collection Systems - Paper

    EPA Science Inventory

    The nation’s sanitary sewer infrastructure is aging, with some sewers dating back more than 100 years. Nationwide, there are more than 19,500 municipal sanitary-sewer collection systems serving an estimated 150 million people and about 40,000 sanitary sewer overflow (SSO) events ...

  7. EPA SSOAP Toolbox Application for Condition and Capacity Assessment of Wastewater Collection Systems

    EPA Science Inventory

    The Nation’s sanitary sewer infrastructure is aging, with some sewers dating back over 100 years. Nationwide, there are more than 19,500 municipal sanitary-sewer collection systems serving an estimated 150 million people and about 40,000 sanitary sewer overflow (SSO) events per ...

  8. Contaminant transport pathways between urban sewer networks and water supply wells

    USDA-ARS?s Scientific Manuscript database

    Water supply wells and sanitary sewers are critical components of urban infrastructure, but sewer leakage threatens the quality of groundwater in sewered areas. Previous work by our group has documented the presence of human enteric viruses in deep public supply wells. Our current research uses such...

  9. Remaining Sites Verification Package for the 100-F-26:12, 1.8-m (72-in.) Main Process Sewer Pipeline, Waste Site Reclassification Form 2007-034

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. M. Capron

    2008-04-29

    The 100-F-26:12 waste site was an approximately 308-m-long, 1.8-m-diameter east-west-trending reinforced concrete pipe that joined the North Process Sewer Pipelines (100-F-26:1) and the South Process Pipelines (100-F-26:4) with the 1.8-m reactor cooling water effluent pipeline (100-F-19). In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  10. Sewage Monitors

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Every U.S. municipality must determine how much waste water it is processing and more importantly, how much is going unprocessed into lakes and streams either because of leaks in the sewer system or because the city's sewage facilities were getting more sewer flow than they were designed to handle. ADS Environmental Services, Inc.'s development of the Quadrascan Flow Monitoring System met the need for an accurate method of data collection. The system consists of a series of monitoring sensors and microcomputers that continually measure water depth at particular sewer locations and report their findings to a central computer. This provides precise information to city managers on overall flow, flow in any section of the city, location and severity of leaks and warnings of potential overload. The core technology has been expanded upon in terms of both technical improvements, and functionality for new applications, including event alarming and control for critical collection system management problems.

  11. Investigation of Pharmaceutical Residues in Hospital Effluents, in Ground- and Drinking Water from Bundeswehr Facilities, and their Removal During Drinking Water Purification (Arzneimittelrueckstaende in Trinkwasser(versorgungsanlagen) und Krankenhausabwaessern der Bundeswehr: Methodenentwicklung - Verkommen - Wasseraufbereitung)

    DTIC Science & Technology

    1999-11-01

    Drinking water processing plant , Analysis, Calculation model, Field experiment 16. PRICE CODE 17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATION...sewage effluents and from the sewer of the municipal sewage treatment plant in Berlin-Ruhleben. In the field trials, the MDWPUs that both apply reverse...waste water samples, along the municipal sewer system and In the influents and effluents of the receiving sewage treatment plants . To estimate the

  12. Constructing and dismantling frameworks of disease etiology: the rise and fall of sewer gas in America, 1870-1910.

    PubMed Central

    An, Perry G.

    2004-01-01

    For roughly forty years, from 1870 to 1910, Americans recognized and feared gases emanating from sewers, believing that they were responsible for causing an array of diseases. Fears of sewer gas arose from deeper anxieties toward contact with decomposing organic matter and the vapors emitted from such refuse. These anxieties were exacerbated by the construction of sewers across the country during the mid-to-late-nineteenth century, which concentrated waste emanations and connected homes to one another. The result was the birth of sewer gas and the attribution of sickness and death to it, as well as the development of a host of plumbing devices and, especially, bathroom fixtures, to combat sewer gas. The rise of the germ theory, laboratory science, and belief in disease specificity, however, transformed the threat of sewer gas, eventually replacing it (and the larger fear of miasmas) with the threat of germs. The germ theory framework, by 1910, proved more suitable than the sewer gas framework in explaining disease causation; it is this suitability that often shapes the relationship between science and society. PMID:15829149

  13. Remote Infrared Thermal Sensing of Sewer Voids, Four-Year Update

    NASA Astrophysics Data System (ADS)

    Weil, Gary J.

    1988-01-01

    When a sewer caves in, it often takes the street, sidewalks, and surrounding buildings along for the ride. These collapses endanger public health and safety. Repairing a sewer before such a cave-in is obviously the preferred method. Emergency repairs cost far more than prevention measures - often millions of dollars more. Many combined sewers in the St. Louis area, as in many of America's cities, are more than 125 years old and are subject to structural failure. In 1981 alone, St. Louis had 4,000 sewer collapses and an astronomical repair bill. These and similar problems have been described as "a crisis of national proportions. The question addressed by this paper is how to detect unseen problem areas in sewer systems before they give way. At the present, progressive sewer administrations may use crawl crews to inspect sewers when problems are suspected. This can be extremely costly and dangerous, and a void around the outside of the sewer is often invisible from within. Thus, even a crawl crew can fail to detect most voids. Infrared Thermography has been found by sewer districts and independent evaluation engineering firms to be an extremely accurate method of finding sewer voids, before they can cause expensive and dangerous problems. This technique uses a non-contact, remote sensing method, with the potential for surveying large areas quickly and efficiently. This paper reviews our initial paper presented to The International Society for Optical Engineering in October of 1983 and presents an update of our experience, both successes and failures, in several large-scale void detection projects. Infrared Thermographic techniques of non-destructive testing will have major implications for cities and for the engineering profession because it promises to make the crisis of infrastructure repair and rehabilitation more manageable. Intelligent, systematic use of this relatively low cost void detection method, Infrared Thermography, may revolutionize the way sewer problems are handled in the future.

  14. 75 FR 53342 - Notice of Lodging of Proposed Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... including raw sewage from the City's sanitary sewer system and its separate storm sewer system, as well as a... remedial measures, including necessary upgrades to its sanitary sewer system and separate storm sewer system, over a period of approximately twelve years and at an estimated cost of approximately $50 million...

  15. Sulfide and methane production in sewer sediments.

    PubMed

    Liu, Yiwen; Ni, Bing-Jie; Ganigué, Ramon; Werner, Ursula; Sharma, Keshab R; Yuan, Zhiguo

    2015-03-01

    Recent studies have demonstrated significant sulfide and methane production by sewer biofilms, particularly in rising mains. Sewer sediments in gravity sewers are also biologically active; however, their contribution to biological transformations in sewers is poorly understood at present. In this study, sediments collected from a gravity sewer were cultivated in a laboratory reactor fed with real wastewater for more than one year to obtain intact sediments. Batch test results show significant sulfide production with an average rate of 9.20 ± 0.39 g S/m(2)·d from the sediments, which is significantly higher than the areal rate of sewer biofilms. In contrast, the average methane production rate is 1.56 ± 0.14 g CH4/m(2)·d at 20 °C, which is comparable to the areal rate of sewer biofilms. These results clearly show that the contributions of sewer sediments to sulfide and methane production cannot be ignored when evaluating sewer emissions. Microsensor and pore water measurements of sulfide, sulfate and methane in the sediments, microbial profiling along the depth of the sediments and mathematical modelling reveal that sulfide production takes place near the sediment surface due to the limited penetration of sulfate. In comparison, methane production occurs in a much deeper zone below the surface likely due to the better penetration of soluble organic carbon. Modelling results illustrate the dependency of sulfide and methane productions on the bulk sulfate and soluble organic carbon concentrations can be well described with half-order kinetics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Tree root intrusion in sewer systems: A review of extent and costs

    Treesearch

    T.B. Randrup; E.G. McPherson; L.R. Costello

    2001-01-01

    Interference between trees and sewer systems is likely to occur in old systems and in cracked pipes. Factors that contribute to damage include old pipes with joints, shallow pipes, small-dimension pipes, and fast-growing tree species. Because roots are reported to cause >50% of all sewer blockages, costs associated with root removal from sewers is substantial. In...

  17. One-dimensional modelling of the interactions between heavy rainfall-runoff in an urban area and flooding flows from sewer networks and rivers.

    PubMed

    Kouyi, G Lipeme; Fraisse, D; Rivière, N; Guinot, V; Chocat, B

    2009-01-01

    Many investigations have been carried out in order to develop models which allow the linking of complex physical processes involved in urban flooding. The modelling of the interactions between overland flows on streets and flooding flows from rivers and sewer networks is one of the main objectives of recent and current research programs in hydraulics and urban hydrology. This paper outlines the original one-dimensional linking of heavy rainfall-runoff in urban areas and flooding flows from rivers and sewer networks under the RIVES project framework (Estimation of Scenario and Risks of Urban Floods). The first part of the paper highlights the capacity of Canoe software to simulate the street flows. In the second part, we show the original method of connection which enables the modelling of interactions between processes in urban flooding. Comparisons between simulated results and the results of Despotovic et al. or Gomez & Mur show a good agreement for the calibrated one-dimensional connection model. The connection operates likes a manhole with the orifice/weir coefficients used as calibration parameters. The influence of flooding flows from river was taken into account as a variable water depth boundary condition.

  18. The characteristics of dissolved organic matter (DOM) in storm sewer sediments and the binding interaction with Cu(II) in four typical regions in Beijing, China.

    PubMed

    Zhang, Ziyang; Li, Kun; Zhang, Xiaoran; Li, Haiyan

    2017-07-01

    In this work, dissolved organic matter (DOM) was extracted from storm sewer sediments collected in four typical regions (residential, campus, traffic and business regions) in Beijing, China. The basic characteristics of DOM were analyzed by UV-visible spectroscopy (UV-Vis), excitation-emission matrix Fluorescence Spectroscopy and Fourier Transform Infrared Spectroscopy. Furthermore, the complexation between DOM and Cu(II) were investigated. The results showed that there were large amount of aromatic structure in the DOM extracted from storm sewer sediments. The microbial activities had also made a contribution to the DOM in storm sewer sediments. The composition of DOM influenced the complexing capacity of Cu(II) greatly, which may be attributed to the protein-like and humic-like substances in storm sewer sediments. This study demonstrated valuable information on the structure present in the DOM of storm sewer sediments and provided new insight for exploring the relationship between DOM and co-existing heavy metals in storm sewer sediments.

  19. Degradability of creatinine under sewer conditions affects its potential to be used as biomarker in sewage epidemiology.

    PubMed

    Thai, Phong K; O'Brien, Jake; Jiang, Guangming; Gernjak, Wolfgang; Yuan, Zhiguo; Eaglesham, Geoff; Mueller, Jochen F

    2014-05-15

    Creatinine was proposed to be used as a population normalising factor in sewage epidemiology but its stability in the sewer system has not been assessed. This study thus aimed to evaluate the fate of creatinine under different sewer conditions using laboratory sewer reactors. The results showed that while creatinine was stable in wastewater only, it degraded quickly in reactors with the presence of sewer biofilms. The degradation followed first order kinetics with significantly higher rate in rising main condition than in gravity sewer condition. Additionally, daily loads of creatinine were determined in wastewater samples collected on Census day from 10 wastewater treatment plants around Australia. The measured loads of creatinine from those samples were much lower than expected and did not correlate with the populations across the sampled treatment plants. The results suggested that creatinine may not be a suitable biomarker for population normalisation purpose in sewage epidemiology, especially in sewer catchment with high percentage of rising mains. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Quantification of sewer system infiltration using delta(18)O hydrograph separation.

    PubMed

    Prigiobbe, V; Giulianelli, M

    2009-01-01

    The infiltration of parasitical water into two sewer systems in Rome (Italy) was quantified during a dry weather period. Infiltration was estimated using the hydrograph separation method with two water components and delta(18)O as a conservative tracer. The two water components were groundwater, the possible source of parasitical water within the sewer, and drinking water discharged into the sewer system. This method was applied at an urban catchment scale in order to test the effective water-tightness of two different sewer networks. The sampling strategy was based on an uncertainty analysis and the errors have been propagated using Monte Carlo random sampling. Our field applications showed that the method can be applied easily and quickly, but the error in the estimated infiltration rate can be up to 20%. The estimated infiltration into the recent sewer in Torraccia is 14% and can be considered negligible given the precision of the method, while the old sewer in Infernetto has an estimated infiltration of 50%.

  1. Identifying the best locations to install flow control devices in sewer networks to enable in-sewer storage

    NASA Astrophysics Data System (ADS)

    Leitão, J. P.; Carbajal, J. P.; Rieckermann, J.; Simões, N. E.; Sá Marques, A.; de Sousa, L. M.

    2018-01-01

    The activation of available in-sewer storage volume has been suggested as a low-cost flood and combined sewer overflow mitigation measure. However, it is currently unknown what the attributes for suitable objective functions to identify the best location for flow control devices are and the impact of those attributes on the results. In this study, we present a novel location model and efficient algorithm to identify the best location(s) to install flow limiters. The model is a screening tool that does not require hydraulic simulations but rather considers steady state instead of simplistic static flow conditions. It also maximises in-sewer storage according to different reward functions that also considers the potential impact of flow control device failure. We demonstrate its usefulness on two real sewer networks, for which an in-sewer storage potential of approximately 2,000 m3 and 500 m3 was estimated with five flow control devices installed.

  2. Sewer System Management Plan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holland, Robert C.

    A Sewer System Management Plan (SSMP) is required by the State Water Resources Control Board (SWRCB) Order No. 2006-0003-DWQ Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems (General Permit). DOE, National Nuclear Security Administration (NNSA), Sandia Field Office has filed a Notice of Intent to be covered under this General Permit. The General Permit requires a proactive approach to reduce the number and frequency of sanitary sewer overflows (SSOs) within the State. SSMPs must include provisions to provide proper and efficient management, operation, and maintenance of sanitary sewer systems and must contain a spill response plan.

  3. Green-blue water in the city: quantification of impact of source control versus end-of-pipe solutions on sewer and river floods.

    PubMed

    De Vleeschauwer, K; Weustenraad, J; Nolf, C; Wolfs, V; De Meulder, B; Shannon, K; Willems, P

    2014-01-01

    Urbanization and climate change trends put strong pressures on urban water systems. Temporal variations in rainfall, runoff and water availability increase, and need to be compensated for by innovative adaptation strategies. One of these is stormwater retention and infiltration in open and/or green spaces in the city (blue-green water integration). This study evaluated the efficiency of three adaptation strategies for the city of Turnhout in Belgium, namely source control as a result of blue-green water integration, retention basins located downstream of the stormwater sewers, and end-of-pipe solutions based on river flood control reservoirs. The efficiency of these options is quantified by the reduction in sewer and river flood frequencies and volumes, and sewer overflow volumes. This is done by means of long-term simulations (100-year rainfall simulations) using an integrated conceptual sewer-river model calibrated to full hydrodynamic sewer and river models. Results show that combining open, green zones in the city with stormwater retention and infiltration for only 1% of the total city runoff area would lead to a 30 to 50% reduction in sewer flood volumes for return periods in the range 10-100 years. This is due to the additional surface storage and infiltration and consequent reduction in urban runoff. However, the impact of this source control option on downstream river floods is limited. Stormwater retention downstream of the sewer system gives a strong reduction in peak discharges to the receiving river. However due to the difference in response time between the sewer and river systems, this does not lead to a strong reduction in river flood frequency. The paper shows the importance of improving the interface between urban design and water management, and between sewer and river flood management.

  4. [Research on pollution load of sediments in storm sewer in Beijing district].

    PubMed

    Li, Hai-Yan; Xu, Bo-Ping; Xu, Shang-Ling; Cui, Shuang

    2013-03-01

    Based on the investigation of sewer sediments in Xi Cheng district in Beijing, scour-release pollution load in one rainfall from sewer sediments was studied by monitoring the pollutants in the run-off of manhole's section. It was shown that the contribution of scour-release pollutants from sewer sediments to sewer outflow was obvious. The contribution rate of the sediments pollution load to runoff outflow in the 84 m pipeline in one rainfall (9 Jul., 2010) was as follows: TN 8.5%, TP 8.2%, COD 18.3%, SS 7.7%, respectively. And the pollutant contribution rate in the 295 m pipeline in another rainfall (4 Aug., 2010) was TN 23.12%, TP 60.01%, COD 33.78%, SS 31.89%. Therefore, it is important to control the pollution from sewer sediments for the improvement of water environment.

  5. A Bayesian network model to assess the public health risk associated with wet weather sewer overflows discharging into waterways.

    PubMed

    Goulding, R; Jayasuriya, N; Horan, E

    2012-10-15

    Overflows from sanitary sewers during wet weather, which occur when the hydraulic capacity of the sewer system is exceeded, are considered a potential threat to the ecological and public health of the waterways which receive these overflows. As a result, water retailers in Australia and internationally commit significant resources to manage and abate sewer overflows. However, whilst some studies have contributed to an increased understanding of the impacts and risks associated with these events, they are relatively few in number and there still is a general lack of knowledge in this area. A Bayesian network model to assess the public health risk associated with wet weather sewer overflows is presented in this paper. The Bayesian network approach is shown to provide significant benefits in the assessment of public health risks associated with wet weather sewer overflows. In particular, the ability for the model to account for the uncertainty inherent in sewer overflow events and subsequent impacts through the use of probabilities is a valuable function. In addition, the paper highlights the benefits of the probabilistic inference function of the Bayesian network in prioritising management options to minimise public health risks associated with sewer overflows. Copyright © 2012. Published by Elsevier Ltd.

  6. Trail Creek II: Modeling Flow and E. Coli Concentrations in a Small Urban Stream using SWAT

    NASA Astrophysics Data System (ADS)

    Radcliffe, D. E.; Saintil, T.

    2017-12-01

    Pathogens are one of the leading causes of stream and river impairment in the State of Georgia. The common presence of fecal bacteria is driven by several factors including rapid population growth stressing pre-existing and ageing infrastructure, urbanization and poor planning, increase percent imperviousness, urban runoff, municipal discharges, sewage, pet/wildlife waste and leaky septic tanks. The Trail Creek watershed, located in Athens-Clarke County, Georgia covers about 33 km2. Stream segments within Trail Creek violate the GA standard due to high levels of fecal coliform bacteria. In this study, the Soil and Water Assessment Tool (SWAT) modeling software was used to predict E. coli bacteria concentrations during baseflow and stormflow. Census data from the county was used for human and animal population estimates and the Fecal Indicator Tool to generate the number of colony forming units of E. Coli for each source. The model was calibrated at a daily time step with one year of monitored streamflow and E. coli bacteria data using SWAT-CUP and the SUFI2 algorithm. To simulate leaking sewer lines, we added point sources in the five subbasins in the SWAT model with the greatest length of sewer line within 50 m of the stream. The flow in the point sources were set to 5% of the stream flow and the bacteria count set to that of raw sewage (30,000 cfu/100 mL). The calibrated model showed that the average load during 2003-2013 at the watershed outlet was 13 million cfu per month. Using the calibrated model, we simulated scenarios that assumed leaking sewers were repaired in one of the five subbasins with point sources. The reduction ranged from 10 to 46%, with the largest reduction in subbasin in the downtown area. Future modeling work will focus on the use of green infrastructure to address sources of bacteria.

  7. Quantification of groundwater infiltration and surface water inflows in urban sewer networks based on a multiple model approach.

    PubMed

    Karpf, Christian; Krebs, Peter

    2011-05-01

    The management of sewer systems requires information about discharge and variability of typical wastewater sources in urban catchments. Especially the infiltration of groundwater and the inflow of surface water (I/I) are important for making decisions about the rehabilitation and operation of sewer networks. This paper presents a methodology to identify I/I and estimate its quantity. For each flow fraction in sewer networks, an individual model approach is formulated whose parameters are optimised by the method of least squares. This method was applied to estimate the contributions to the wastewater flow in the sewer system of the City of Dresden (Germany), where data availability is good. Absolute flows of I/I and their temporal variations are estimated. Further information on the characteristics of infiltration is gained by clustering and grouping sewer pipes according to the attributes construction year and groundwater influence and relating these resulting classes to infiltration behaviour. Further, it is shown that condition classes based on CCTV-data can be used to estimate the infiltration potential of sewer pipes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Factors affecting economies of scale in combined sewer systems.

    PubMed

    Maurer, Max; Wolfram, Martin; Anja, Herlyn

    2010-01-01

    A generic model is introduced that represents the combined sewer infrastructure of a settlement quantitatively. A catchment area module first calculates the length and size distribution of the required sewer pipes on the basis of rain patterns, housing densities and area size. These results are fed into the sewer-cost module in order to estimate the combined sewer costs of the entire catchment area. A detailed analysis of the relevant input parameters for Swiss settlements is used to identify the influence of size on costs. The simulation results confirm that an economy of scale exists for combined sewer systems. This is the result of two main opposing cost factors: (i) increased construction costs for larger sewer systems due to larger pipes and increased rain runoff in larger settlements, and (ii) lower costs due to higher population and building densities in larger towns. In Switzerland, the more or less organically grown settlement structures and limited land availability emphasise the second factor to show an apparent economy of scale. This modelling approach proved to be a powerful tool for understanding the underlying factors affecting the cost structure for water infrastructures.

  9. Modeling of wastewater quality in an urban area during festival and rainy days.

    PubMed

    Obaid, H A; Shahid, S; Basim, K N; Chelliapan, S

    2015-01-01

    Water pollution during festival periods is a major problem in all festival cities across the world. Reliable prediction of water pollution is essential in festival cities for sewer and wastewater management in order to ensure public health and a clean environment. This article aims to model the biological oxygen demand (BOD(5)), and total suspended solids (TSS) parameters in wastewater in the sewer networks of Karbala city center during festival and rainy days using structural equation modeling and multiple linear regression analysis methods. For this purpose, 34 years (1980-2014) of rainfall, temperature and sewer flow data during festival periods in the study area were collected, processed, and employed. The results show that the TSS concentration increases by 26-46 mg/l while BOD(5) concentration rises by 9-19 mg/l for an increase of rainfall by 1 mm during festival periods. It was also found that BOD(5) concentration rises by 4-17 mg/l for each increase of 10,000 population.

  10. Vacuum Flushing of Sewer Solids

    EPA Science Inventory

    The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...

  11. City sewer collectors biocorrosion

    NASA Astrophysics Data System (ADS)

    Ksiażek, Mariusz

    2014-12-01

    This paper presents the biocorrosion of city sewer collectors impregnated with special polymer sulphur binders, polymerized sulphur, which is applied as the industrial waste material. The city sewer collectors are settled with a colony of soil bacteria which have corrosive effects on its structure. Chemoautotrophic nitrifying bacteria utilize the residues of halites (carbamide) which migrate in the city sewer collectors, due to the damaged dampproofing of the roadway and produce nitrogen salts. Chemoorganotrophic bacteria utilize the traces of organic substrates and produce a number of organic acids (formic, acetic, propionic, citric, oxalic and other). The activity of microorganisms so enables the origination of primary and secondary salts which affect physical properties of concretes in city sewer collectors unfavourably.

  12. The influence of biodegradability of sewer solids for the management of CSOs.

    PubMed

    Sakrabani, R; Ashley, R M; Vollertsen, J

    2005-01-01

    The re-suspension of sediments in combined sewers and the associated pollutants into the bulk water during wet weather flows can cause pollutants to be carried further downstream to receiving waters or discharged via Combined Sewer Overflows (CSO). A typical pollutograph shows the trend of released bulk pollutants with time but does not consider information on the biodegradability of these pollutants. A new prediction methodology based on Oxygen Utilisation Rate (respirometric method) and Erosionmeter (laboratory device replicating in-sewer erosion) experiments is proposed which is able to predict the trends in biodegradability during in-sewer sediment erosion in wet weather conditions. The proposed new prediction methodology is also based on COD fractionation techniques.

  13. Savannah River Plant engineering and design history. Volume 4: 300/700 Areas & general services and facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1957-01-01

    The primary function of the 300 Area is the production and preparation of the fuel and target elements required for the 100 Area production reactors. Uranium slugs and lithium-aluminium alloy control and blanket rods are prepared in separate structures. Other facilities include a test pile, a physics assembly laboratory, an office and change house, an electrical substation, and various service facilities such as rail lines, roads, sewers, steam and water distribution lines, etc. The 700 Area contains housing and facilities for plant management, general plant services, and certain technical activities. The technical buildings include the Main Technical Laboratory, the Wastemore » Concentration Building, the Health Physics Headquarters, and the Health Physics Calibration building. Sections of this report describe the following: development of the 300-M Area; selection and description of process; design of main facilities of the 300 Area; development of the 700-A Area; design of the main facilities of the 700 Area; and general services and facilities, including transportation, plant protection, waste disposal and drainage, site work, pilot plants, storage, and furniture and fixtures.« less

  14. Contribution of different sources to the pollution of wet weather flows in combined sewers.

    PubMed

    Gromaire, M C; Garnaud, S; Saad, M; Chebbo, G

    2001-02-01

    Experiments performed on "Marais" catchment, in central Paris, aimed to follow up the quality of wet weather flows from the entry to the exit of a combined sewer network. SS, VSS, COD, BOD5, Cd, Cu, Pb, Zn concentrations were measured for an important number of rain events in roof, yard, street runoff, as well as in dry and wet weather flows at the catchment outlet. Mass entry-exit totals, at the scale of the catchment, were calculated over 31 rain events in order to evaluate the contribution of different types of runoff, of sanitary sewage and of sewer sediments to the total wet weather pollutant loads at the catchment outlet. The erosion of in-sewer pollutant stocks was found to be the main source of particles and of organic matter in wet weather flows, whereas heavy metal loads mainly originated from roof runoff, due to the corrosion of metallic roofs. Particles eroded inside the sewer during rain events were found to be quite different from the particles constituting the main part of sewer sediments: they are organic and biodegradable, with rather important settling velocities and seem to accumulate during dry weather periods. A change of the chemical form of heavy metals was noticed during the transport in the sewer and it is suspected that a fraction of the dissolved metals from the runoff is adsorbed on sewer sediments.

  15. [Transport and sources of runoff pollution from urban area with combined sewer system].

    PubMed

    Li, Li-Qing; Yin, Cheng-Qing

    2009-02-15

    Sampling and monitoring of runoff and sewage water in Wuhan urban area with combined sewer system were carried out during the period from 2003 to 2006, to study the transport and sources of runoff pollution at the catchment scale coupled with environmental geochemistry method. The results showed a change in quality between the runoff entering the sewer network and the combined storm water flow at the sewer's outlet. A significant increase was observed in the concentrations of total suspended solids (TSS), volatile suspended solids (VSS), COD, TN, and TP, and in the proportion of COD linked to particles. During the runoff production and transport, the concentrations of TSS and COD increased from 18.7 mg/L and 37.0 mg/L in roof runoff, to 225.3 mg/L and 176.5 mg/L in street runoff, and to 449.7 mg/L and 359.9 mg/L in combined storm water flow, respectively. The proportion of COD linked to particles was increased by 18%. In addition, the total phosphorus (P) and iron (Fe) contents in urban ground dust, storm drain sediment, sewage sewer sediment and combined sewer sediment were measured to identify the potential sources of suspended solids in the combined flow. The urban ground dust andstorm drain sediment wererich in Fe, whereas the sewage sewer sediment was rich in P. The P/Fe ratios in these groups were significantly distinct and able to differentiate them. A calculation of the two storm events based on the P/Fe rations showed that 56% +/- 26% of suspended solids in combined flow came from urban ground and storm drain. The rest wer e originated from the sewage sewer sediments which deposited in combined sewer on the dry weather days and were eroded on the wet weather days. The combined sewer network not only acts as a transport system, but also constitutes a physicochemical reactor that degrades the quality of urban water. Reducing the in-sewer pollution stocks would effectively control urban runoff pollution.

  16. Vacuum Flushing of Sewer Solids (Slides)

    EPA Science Inventory

    The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...

  17. MANAGEMENT AND CONTROL OF COMBINED SEWER OVERFLOWS

    EPA Science Inventory

    The paper gives a basic overview of the U.S. government's involvements in developing countermeasures for the abatement of combined sewer overflow pollution. batement or prevention of pollution stormwater runoff and combined sewer overflows is one of the most challenging areas in ...

  18. SANITARY-SEWER OVERFLOW CONTROL STRATEGY

    EPA Science Inventory

    This paper presents a strategy for the abatement of pollution from storm-generated sanitary-sewer overflows (SSO). Because of the great lengths of sanitary-sewer systems and their associated vast number of house-service laterals or building connections, it is often less expensive...

  19. SSOAP - A USEPA Toolbox for Sanitary Sewer Overflow Analysis and Control Planning - Presentation

    EPA Science Inventory

    The United States Environmental Protection Agency (USEPA) has identified a need to use proven methodologies to develop computer tools that help communities properly characterize rainfall-derived infiltration and inflow (RDII) into sanitary sewer systems and develop sanitary sewer...

  20. CONTROL STRATEGY FOR STORM-GENERATED SANITARY-SEWER OVERFLOWS

    EPA Science Inventory

    This paper presents a strategy for the abatement of pollution from storm-generated sanitary-sewer overflows (SSO). Because of the great lengths of sanitary sewer systems, it is often less expensive to use alterantives to sewerline rehabilitation for infiltration/inflow (I/I) and ...

  1. CONTROL STRATEGY FOR STORM-GENERATED SANITARY-SEWER OVERFLOWS

    EPA Science Inventory

    This paper presents a strategy for the abatement of pollution from storm-generated sanitary-sewer overflows (SSO). Because of the great lengths of sanitary-sewer systems and their associated vast number of house-service laterals or building connections, it is often less expensiv...

  2. Sanitary Sewer Overflow Analysis and Planning (SSOAP) Toolbox

    EPA Science Inventory

    Rainfall-derived infiltration and inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby receiving waters and can also ...

  3. NPDES Permit for Denver Federal Center Municipal Separate Storm Sewer System in Colorado

    EPA Pesticide Factsheets

    Denver Federal Center Municipal Separate Storm Sewer System is authorized to discharge from all municipal separate storm sewer outfalls existing as of the effective date of permit CO-R042004 to receiving waters Lakewood, Jefferson County, Colorado.

  4. Control Strategy for Storm-Generated Sanitary Sewer Overflows

    EPA Science Inventory

    This presentation covers a strategy for the abatement of pollution from sanitary-sewer overflows (SSO). Because of the great lengths of sanitary sewer systems, it is often less expensive to use alternatives to sewerline rehabilitation for infiltration/inflow (I/I) and associated ...

  5. URBAN WET-WEATHER FLOW MANAGEMENT: RESEARCH DIRECTIONS

    EPA Science Inventory

    There are three types of urban wet-weather flow (WWF) discharges: 1) combined-sewer overflow (CSO), which is a mixture of storm drainage and municipal-industrial wastewater discharged from combined sewers or dry-weather flow discharged from combined sewers due to clogged intercep...

  6. Environmental Assessment for the Expansion and Consolidation of the Base Exchange at Joint Base Andrews-Naval Air Facility Washington, Prince George’s County, Maryland

    DTIC Science & Technology

    2013-08-01

    Wildlife Service VOC volatile organic compound WG/CC Wing, Commanding Officer WSSC Washington Suburban Sanitary Commission WWTP waste water...2009a). 3.3 Infrastructure and Utilities 3.3.1 Wastewater Collection and Treatment Sanitary Sewer The sanitary sewer system at JBA was privatized...in February 2006. Terrapin Utility Services, Inc., owns and operates the sanitary sewer system (JBA-NAFW 2013). The majority of the sanitary sewer

  7. Dynamics of rain-induced pollutographs of solubles in sewers.

    PubMed

    Rutsch, M; Müller, I; Krebs, P

    2005-01-01

    When looking at acute receiving water impacts due to combined sewer overflows the characteristics of the background diurnal sewage flux variation may influence the peak loads from combined sewer overflows (CSO) and wastewater treatment plant (WWTP) effluent significantly. In this paper, effects on the dynamic compounds transported in the sewer, on CSO discharges and WWTP loading are evaluated by means of hydrodynamic simulations. The simulations are based on different scenarios for diurnal dry-weather flow variations induced by different infiltration rates.

  8. The use of multiple tracers to evaluate the impact of sewered and non-sewered development on coastal water quality in a rural area of Florida.

    PubMed

    Meeroff, Daniel E; Bloetscher, Frederick; Long, Sharon C; Bocca, Thais

    2014-05-01

    When onsite wastewater treatment and disposal systems (OSTDS) are not sited appropriately or installed properly, wastewater constituents can be a source of adverse environmental impacts to soil and groundwater, which can lead to potential public health risks. A paired monitoring design developed to compare water quality in sewered and non-sewered areas is presented here. It is suggested as a possible monitoring scheme for assessing the impact of sewer installation projects. As such, two sets of single-family, rural residential Florida neighborhoods were evaluated over a two-year period to gain insight into the effects of small-community use of OSTDS on coastal water quality. One set of two neighborhoods were connected to the sanitary sewer network and the other set of two were served exclusively by OSTDS. Water quality sampling was conducted at the paired sites during seasonal high water table (SHWT) and seasonal low water table (SLWT) events. Measured surface water quality during the SHWT showed indications of environmental impacts from OSTDS in terms of nutrients, microbial pathogen indicators, and other water quality measures, such as turbidity and conductivity. However, during the SLWT events, no obvious impacts attributable to OSTDS were detected. The water quality results indicate that OSTDS impacts may be measureable in rural areas. Other factors, such as microbial indicator survival and regrowth potential, may confound the understanding of water quality impacts of sewer projects. For example, the microbial indicators Escherichia coli and enterococci were found to persist over time and therefore did not always represent true comparisons of OSTDS and sewered areas between seasons. The timeframe for evaluating the effects of sewer projects may be longer than anticipated because of this survival and regrowth phenomenon.

  9. Dissolved oxygen in gravity sewers--measurement and simulation.

    PubMed

    Gudjonsson, G; Vollertsen, J; Hvitved-Jacobsen, T

    2002-01-01

    Dissolved oxygen (DO) concentrations were during 2 months continuously measured in an intercepting sewer. Measurements were made upstream and downstream in a 3.6 km gravity sewer. DO showed significant diurnal variations mainly caused by changes in the organic matter composition of the wastewater. At low temperatures the gravity sewer was strictly aerobic. However, towards the end of the measuring campaign, DO concentrations decreased as temperature increased and the sewer became anaerobic part of the day. A conceptual model that takes into account bulk water and biofilm DO uptake as well as reaeration was used to simulate the DO measured. Using measurements from the upstream station as input, the model was calibrated to yield good validation results of the DO at the downstream station.

  10. Multi-element sewer slime impact pattern--a quantitative characteristic enabling identification of the source of heavy metal discharges into sewer systems.

    PubMed

    Kintrup, J; Wünsch, G

    2001-11-01

    The capability of sewer slime to accumulate heavy metals from municipal wastewater can be exploited to identify the sources of sewage sludge pollution. Former investigations of sewer slime looked for a few elements only and could, therefore, not account for deviations of the enrichment efficiency of the slime or for irregularities from sampling. Results of ICP-MS multi element determinations were analyzed by multivariate statistical methods. A new dimensionless characteristic "sewer slime impact" is proposed, which is zero for unloaded samples. Patterns expressed in this data format specifically extract the information required to identify the type of pollution and polluter quicker and with less effort and cost than hitherto.

  11. Different erosion characteristics of sediment deposits in combined and storm sewers.

    PubMed

    Xu, Zuxin; Wu, Jun; Li, Huaizheng; Liu, Zhenghua; Chen, Keli; Chen, Hao; Xiong, Lijun

    2017-04-01

    To investigate the different erosion patterns of sediments in combined and storm sewers, sediments from three separate sewer systems and two combined sewer systems in urban Shanghai were collected for the flushing experiments. These experiments were conducted with different consolidation periods and shear velocities. As the consolidation period increases, dissolved oxygen exhibits a positive effect on the microbial transformations of organic substrates. Potential structural changes and separations of the surface and bottom layers of sediments are observed. The results also reveal that the organic matter, particle size and moisture have different effects on the erosion resistance of sediments. Furthermore, illicit connections behaved as an important factor affecting the viscosity and static friction force of particles, which directly alter the erosion resistance of sewer sediments.

  12. Hydrogen sulphide removal from corroding concrete: comparison between surface removal rates and biomass activity.

    PubMed

    Jensen, H S; Nielsen, A H; Lens, P N L; Hvitved-Jacobsen, T; Vollertsen, J

    2009-11-01

    Corrosion of concrete sewer pipes caused by hydrogen sulphide is a problem in many sewer networks. The mechanisms of production and fate of hydrogen sulphide in the sewer biofilms and wastewater as well as its release to the sewer atmosphere are largely understood. In contrast, the mechanisms of the uptake of hydrogen sulphide on the concrete surfaces and subsequent concrete corrosion are basically unknown. To shed light on these mechanisms, the uptake of hydrogen sulphide from a sewer gas phase was compared to the biological hydrogen sulphide removal potential of the concrete corrosion products. The results showed that both microbial degradation at and sorption to the concrete surfaces were important for the uptake of hydrogen sulphide on the concrete surfaces.

  13. Review of Sewer Design Criteria and RDII Prediction Methods

    EPA Science Inventory

    Rainfall-derived Infiltration and Inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby streams and can also cause serio...

  14. SEWER AND TANK FLUSHING FOR CORROSION AND POLLUTION CONTROL

    EPA Science Inventory

    This paper presents an overview of the causes of sewer deterioration and control methods that can prevent or arrest this deterioration. articular, the paper addresses the use of inline- and combined sewer overflow (CSO) storage tank-flushing systems for removing sediments and mi...

  15. Focused Field Investigations for Sewer Condition Assessment with EPA SSOAP Toolbox

    EPA Science Inventory

    The Nation’s sanitary sewer infrastructure is aging, and is currently one of the top national water program priorities. The U.S. Environmental Protection Agency (EPA) developed the Sanitary Sewer Overflow Analysis and Planning (SSOAP) Toolbox to assist communities in developing ...

  16. SEWER AND TANK FLUSHING FOR SEDIMENT, CORROSION AND POLLUTION CONTROL

    EPA Science Inventory

    This paper presents an overview of causes of sewer deterioration together with a discussion of control methods that can prevent or arrest this deterioration. In particular, the paper covers inline- and combined sewer overflow- (CSO) storage-tank-flushing systems for removal of se...

  17. Hydrologic monitoring for Chicago’s Sustainable Streetscapes Program

    USGS Publications Warehouse

    Duncker, James J.; Morrow, William S.

    2016-04-05

    The Chicago Department of Transportation’s Sustainable Streetscapes Program is an innovative program that strives to convert Chicago’s neighborhood commercial areas, riverwalks, and bicycle facilities into active, attractive places for Chicagoans to live, work, and play. The objective of each project is to create flourishing public places while improving the ability of infrastructure to support dense urban living. The U.S. Geological Survey (USGS), in cooperation with the Metropolitan Water Reclamation District of Greater Chicago (MWRDGC), and the Chicago Department of Transportation (CDOT), is monitoring the pre- and postconstruction hydrologic characteristics of an urban corridor on the south side of Chicago that is being renovated using sustainable streetscapes technology.The CDOT Sustainable Streetscapes Program utilizes urban stormwater best-management practices (BMPs) to reduce the storm runoff to the local combined sewer system. The urban stormwater BMPs include permeable pavement, bioswales, infiltration basins, and planters. The urban stormwater BMPs are designed to capture the first flush of storm runoff through features that enhance the infiltration of stormwater runoff to shallow groundwater.The hydrology of the Sustainable Streetscapes Program area is being monitored to evaluate the impacts and effectiveness of the urban stormwater BMP’s. Continuous monitoring of rainfall, sewer flows, stormwater runoff, soil moisture, and groundwater levels will give engineers and scientists measured data to define baseline pre- and postconstruction conditions for the evaluation of the BMPs.Three tipping-bucket rain gages are located along the project corridor. The data provide information on the intensity and volume of rainfall. Rainfall can be highly variable even over a small area like the project corridor.Continuous recording meters are located at specific locations in the combined sewers to record water level and flow during both dry weather (mostly sanitary flow) and wet weather conditions (stormwater runoff in addition to the sanitary flow). Sanitary flow is the largest source of flow in the combined sewers during dry weather, and stormwater runoff and sanitary flow combine during wet weather. The sewer flow data allow engineers and scientists to calculate total runoff volume for selected storm events.Wells are located within the project corridor to record water levels and help determine the direction of movement of groundwater in response to rainfall and snowmelt. In urban settings with aging sewer systems, groundwater can seep into the sewers or combined sewage can seep from the sewers into the local groundwater system. The groundwater data are also important in evaluating the overall impacts of increased infiltration resulting from BMPs.Data from wells show the relative water levels of shallow groundwater, water levels in the combined sewer system, and nearby surface-water channels within the project corridor. In some aging urban sewer systems, the local combined sewer system lies below the water table and receives substantial amounts of groundwater inflow, which can significantly reduce the amount of additional water the sewer system can accept.The bioswale along the south side of West Cermak Road near South Throop Street functions to infiltrate stormwater runoff from the road. Stormwater on the road surface initially drains to the curb and then flows along the curb until it reaches a curb cut-out. Materials within the bioswale allow stormwater to infiltrate and reduce the load to the combined sewer.A common feature in urban areas are curbside catch basins that collect stormwater runoff from paved streets. Stormwater drains first to the curb and then flows along the curb to the catch basin. Lateral sewer pipe connects the catch basin to the combined sewer beneath the street. The use of permeable pavers along the curbs in the project study reach let stormwater infiltrate before it reaches the curb, thus reducing the amount of stormwater draining to the combined sewers.Water-level data from catch basins in the project study area show the effects of permeable pavers in reducing the stormwater drainage to the combined sewers.

  18. SEWER SEDIMENT CONTROL: AN OVERVIEW OF THE EPA WET WEATHER FLOW (WWF) RESEARCH PROGRAM

    EPA Science Inventory

    This paper presents an overview of EPA WWF Research Program projects related to causes of sewer solids deposition and control methods that can prevent accumulation of sewer sediments. In particular, discussion will focus on the relationship of wastewater characteristics to flow ...

  19. SEWER-SEDIMENT CONTROL: OVERVIEW OF AN EPA WET-WEATHER FLOW RESEARCH PROGRAM

    EPA Science Inventory

    This paper presents a historical overview of the sewer sediment control projects conducted by the Wet-Weather Flow Research Program of the USEPA. Research presented includes studies of the causes of sewer solids deposition and development/evaluation of control methods that can pr...

  20. COMPUTER TOOLS FOR SANITARY SEWER SYSTEM CAPACITY ANALYSIS AND PLANNING

    EPA Science Inventory

    Rainfall-derived infiltration and inflow (RDII) into sanitary sewer systems has long been recognized as a major source of operating problems, causing poor performance of many sewer systems. RDII is the main cause of SSOs to customer basements, streets, or nearby streams and can a...

  1. DEVELOPMENT OF SANITARY SEWER OVERFLOW ANALYSIS AND PLANNING (SSOAP) TOOLBOX

    EPA Science Inventory

    Rainfall Derived Infiltration and Inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby streams. RDII can also cause se...

  2. SSOAP - A TOOLBOX FOR SANITARY SEWER OVERFLOW ANALYSIS AND PLANNING

    EPA Science Inventory

    Rainfall Derived Infiltration and Inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby streams and can also cause serio...

  3. SSOAP - A TOOLBOX FOR SANITARY SEWER OVERFLOW ANALYSIS AND PLANNING

    EPA Science Inventory

    Rainfall Derived Infiltration and Inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby streams and can also cause seriou...

  4. Association between Gastrointestinal Illness and Precipitation in Areas Impacted by Combined Sewer Systems: Utilizing a Distributed Lag Model

    EPA Science Inventory

    Combined sewer systems collect rainwater runoff, sewage, and industrial wastewater for transit to treatment facilities. With heavy precipitation, volumes can exceed capacity of treatment facilities, and wastewater discharges directly to receiving waters. These combined sewer over...

  5. Focused Field Investigations for Sewer Condition Assessment with EPA SSOAP Toolbox - slides

    EPA Science Inventory

    The Nation’s sanitary sewer infrastructure is aging, and is currently one of the top national water program priorities. The U.S. Environmental Protection Agency (EPA) developed the Sanitary Sewer Overflow Analysis and Planning (SSOAP) Toolbox to assist communities in developing S...

  6. INNOVATIVE METHODS FOR THE OPTIMIZATION OF GRAVITY STORM SEWER DESIGN

    EPA Science Inventory

    The purpose of this paper is to describe a new method for optimizing the design of urban storm sewer systems. Previous efforts to optimize gravity sewers have met with limited success because classical optimization methods require that the problem be well behaved, e.g. describ...

  7. Combining land use information and small stream sampling with PCR-based methods for better characterization of diffuse sources of human fecal pollution.

    PubMed

    Peed, Lindsay A; Nietch, Christopher T; Kelty, Catherine A; Meckes, Mark; Mooney, Thomas; Sivaganesan, Mano; Shanks, Orin C

    2011-07-01

    Diffuse sources of human fecal pollution allow for the direct discharge of waste into receiving waters with minimal or no treatment. Traditional culture-based methods are commonly used to characterize fecal pollution in ambient waters, however these methods do not discern between human and other animal sources of fecal pollution making it difficult to identify diffuse pollution sources. Human-associated quantitative real-time PCR (qPCR) methods in combination with low-order headwatershed sampling, precipitation information, and high-resolution geographic information system land use data can be useful for identifying diffuse source of human fecal pollution in receiving waters. To test this assertion, this study monitored nine headwatersheds over a two-year period potentially impacted by faulty septic systems and leaky sanitary sewer lines. Human fecal pollution was measured using three different human-associated qPCR methods and a positive significant correlation was seen between abundance of human-associated genetic markers and septic systems following wet weather events. In contrast, a negative correlation was observed with sanitary sewer line densities suggesting septic systems are the predominant diffuse source of human fecal pollution in the study area. These results demonstrate the advantages of combining water sampling, climate information, land-use computer-based modeling, and molecular biology disciplines to better characterize diffuse sources of human fecal pollution in environmental waters.

  8. Sewer Maintenance Manual.

    ERIC Educational Resources Information Center

    Ontario Ministry of the Environment, Toronto.

    Outlined are practices and procedures that should be followed in order to protect and fully realize the benefits of sewer systems and also to maximize service and minimize inconveniences to the public. Written in practical terms, the manual is designed to be of immediate use to municipal employees and others involved in sewer maintenance…

  9. GATE AND VACUUM FLUSHING OF SEWER SEDIMENT: LABORATORY TESTING

    EPA Science Inventory

    The objective of this study was to test the performance of a traditional gate-flushing device and a newly-designed vacuum-flushing device in removing sediment from combined sewers and CSO storage tanks. A laboratory hydraulic flume was used to simulate a reach of sewer or storag...

  10. Update on the Status of Sanitary Sewer Overflow Analysis and Planning (SSOAP) Toolbox

    EPA Science Inventory

    A properly designed, operated and maintained sanitary sewer system is meant to collect and convey all of the sewage that flows into it to a wastewater treatment plant. However, occasional unintentional discharges of raw sewage from municipal sanitary sewers – called sanitary sewe...

  11. A TOOLBOX FOR SANITARY SEWER OVERFLOW ANALYSIS AND PLANNING (SSOAP) AND APPLICATIONS

    EPA Science Inventory

    Rainfall Derived Infiltration and Inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby streams and can also cause seriou...

  12. 78 FR 20316 - Draft Small Municipal Separate Storm Sewer System NPDES General Permit-New Hampshire; Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-04

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9799-1] Draft Small Municipal Separate Storm Sewer System NPDES General Permit--New Hampshire; Extension of Comment Period AGENCY: Environmental Protection Agency... draft Small Municipal Separate Storm Sewer System (MS4) National Pollutant Discharge Elimination System...

  13. 78 FR 27964 - Draft Small Municipal Separate Storm Sewer System NPDES General Permit-New Hampshire; Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9812-8] Draft Small Municipal Separate Storm Sewer System NPDES General Permit--New Hampshire; Extension of Comment Period AGENCY: Environmental Protection Agency... draft Small Municipal Separate Storm Sewer System (MS4) National Pollutant Discharge Elimination System...

  14. HYDRAULIC CHARACTERISTICS OF SEWER SEDIMENT GATE FLUSHING TANKS: LABORATORY FLUME STUDIES

    EPA Science Inventory

    The objective of this study was to test the performance of gate flushing tanks, simulated in a laboratory flume, to remove sediments from combined sewers and storage tanks. A significant amount of sediment/debris/sludge may accumulate at the bottom of a sewer during dry weather o...

  15. Flood Grouting for Infiltration Reduction on Private Side Sewers (WERF Report INFR5R11)

    EPA Science Inventory

    The sewers in Seattle’s Broadview neighborhood, built in the 1950s, experience significant inflow and infiltration. Intense wet weather events have resulted in sewer overflows into private residences and the environment and previous work indicates that the majority of this excess...

  16. Focused Field Investigations for Sewer Condition Assessment with EPA SSOAP Toolbox - abstract

    EPA Science Inventory

    The Nation’s sanitary sewer infrastructure is aging, and it is currently one of the top national water program priorities, and is one of the top priorities of the U.S. Conference of Mayors. The U.S. Environmental Protection Agency developed the Sanitary Sewer Overflow Analysis a...

  17. HYDRAULIC CHARACTERISTICS OF SEWER SEDIMENT GATE-FLUSHING TANKS: LABORATORY FLUME STUDIES

    EPA Science Inventory

    The objective of this study was to test the performance of gate-flushing tanks, simulated in a laboratory flume, to remove sediments from combined sewers and storage tanks. A significant amount of sediment/debris/sludge may accumulate at the bottom of a sewer during dry weather o...

  18. SEWER SEDIMENT GATE AND VACUUM FLUSHING TANKS: LABORATORY FLUME STUDIES

    EPA Science Inventory

    The objective of this study was to test the performance of a traditional gate-flushing device and a newly designed vacuum-flushing device in removing sediments from combined sewers and CSO storage tanks. A laboratory hydraulic flune was used to simulate a reach of sewer or storag...

  19. 40 CFR 35.2130 - Sewer use ordinance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... integrity of the treatment works; cause violation of effluent or water quality limitations; or preclude the... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2130 Sewer use ordinance. The... any new connections from inflow sources into the treatment works and require that new sewers and...

  20. 40 CFR 35.2130 - Sewer use ordinance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... integrity of the treatment works; cause violation of effluent or water quality limitations; or preclude the... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2130 Sewer use ordinance. The... any new connections from inflow sources into the treatment works and require that new sewers and...

  1. Focused Field Investigations for Sewer Condition Assessment with EPA SSOAP Toolbox

    EPA Science Inventory

    The Nation’s sanitary sewer infrastructure is aging, and it is currently one of the top national water program priorities, and is one of the top priorities of the U.S. Conference of Mayors. The U.S. Environmental Protection Agency (EPA) developed the Sanitary Sewer Overflow Anal...

  2. Statistically based sustainable re-design of stormwater overflow control systems in urban catchments

    NASA Astrophysics Data System (ADS)

    Ganora, Daniele; Isacco, Silvia; Claps, Pierluigi

    2017-04-01

    Control and reduction of pollution from stormwater overflow is a major concern for municipalities to manage the quality of the receiving water bodies according to the Framework Water Directive 2000/60/CE. In this regard, assessment studies of the potential pollution load from sewer networks recognize the need for adaptation and upgrade of existing drainage systems, which can be achieved with either traditional water works (detention tanks, increase of wastewater treatment plant capacity, etc.) or even Nature-based solutions (constructed wetlands, restored floodplains, etc.) sometimes used in combination. Nature-based solutions are recently receiving consistent attentions as they are able to enhance urban and degraded environments being, in the same time, more resilient and adaptable to climatic and anthropic changes than most traditional engineering works. On the other hand, restoration of the urban environment using natural absorbing surfaces requires diffuse interventions, high costs and a considerable amount of time. In this work we investigate how simple, economically-sustainable and quick solutions to the problem at hand can be addressed by changes in the management rules when pumping stations play a role in sewer systems. In particular, we provide a statistically-based framework to be used in the calibration of the management rules, facing improved quality of overflows from sewer systems. Typical pumping rules favor a massive delivery of stormwater volumes to the wastewater treatment plans, requiring large storage tanks in the sewer network, heavy pumping power and reducing the efficiency of the treatment plant due to pollutant dilution. In this study we show that it is possible to optimize the pumping rule in order to reduce pumped volumes to the plant (thus saving energy), while simultaneously keeping high pollutant concentration. On the other hand, larger low-concentration overflow volumes are released outside the sewer network with respect to the standard pumping rules. Such released volumes could be efficiently processed by nature-based solutions, like for instance constructed wetlands, to reduce the final pollutant impact on the environment. The proposed procedure is based on the previous knowledge of the precipitation forcing and of a quantity/quality model of the sewer network. The method provides marginal and joint probability distributions of water volumes and pollutant concentration (or mass) delivered toward the wastewater treatment plant and the Nature-based system, with the aim of supporting a more efficient design of the whole sewer system. A practical example of application is provided for illustrative purposes.

  3. Assessing the Impacts of Pulp Loading from Non-Dispersible Materials on Downstream Sewer Systems (WERF Report INFR1R14)

    EPA Science Inventory

    Abstract:This study subjected wipes from five different manufacturers to a variety of tests to determine if changes to their physical characteristics occur when introduced into a sewer systemand what effect the shredded material (pulp) has on the downstream sewer. Shredded and no...

  4. Final Environmental Assessment for the Disposal of the Former Lynn Haven Fuel Depot, Tyndall Air Force Base, Florida

    DTIC Science & Technology

    2015-12-01

    groundwater), infrastructure/utilities (i.e., sanitary sewer, potable water, solid waste management, drainage, transportation systems, electricity and...on water resources (i.e., surface water and groundwater), infrastructure/utilities (i.e., sanitary sewer, potable water, solid waste management...3-8 3.3.6.4 Sanitary Sewer

  5. Cost Comparison of Conventional Gray Combined Sewer Overflow Control Infrastructure versus a Green/Gray Combination

    EPA Science Inventory

    This paper outlines a life-cycle cost analysis comparing a green (rain gardens) and gray (tunnels) infrastructure combination to a gray-only option to control combined sewer overflow in the Turkey Creek Combined Sewer Overflow Basin, in Kansas City, MO. The plan area of this Bas...

  6. 40 CFR 35.925-21 - Storm sewers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  7. 40 CFR 35.925-21 - Storm sewers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  8. 40 CFR 35.925-21 - Storm sewers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  9. 40 CFR 35.925-21 - Storm sewers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  10. 40 CFR 35.925-21 - Storm sewers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  11. 7. VIEW TO NORTH SHOWING SEWER CONSTRUCTION IN FOREGROUND AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW TO NORTH SHOWING SEWER CONSTRUCTION IN FOREGROUND AND BUILDING F IN THE LEFT BACKGROUND. 8X10 black and white gelatin print. United States Coast Guard, Air Station Contract 1247, Sewer System. 1956. - U.S. Coast Guard Air Station San Francisco, 1020 North Access Road, San Francisco, San Francisco County, CA

  12. Extreme Precipitation and Emergency Room Visits for Gastrointestinal Illness in Areas With and Without Combined Sewer Systems: An Analysis of Massachusetts Data, 2003-2007

    EPA Science Inventory

    Background: Combined sewer overflows (CSOs) occur in combined sewer systems when sewage and stormwater runoff discharge into waterbodies potentially contaminating water sources. CSOs are often caused by heavy precipitation and are expected to increase with increasing extreme pre...

  13. The Distribution and Movement of American Cockroaches in Urban Niches of New Orleans.

    PubMed

    Carlson, John C; Rabito, Felicia A; Werthmann, Derek; Fox, Mark

    2017-10-01

    American cockroaches are an important source of household allergens in tropical and semitropical climates. To determine which outdoor niches produce American cockroaches, traps were placed at 40 homes in New Orleans to collect nymphs. Nymphs were collected from the sewers, yards, and within the homes themselves. To compare sewers and yards as sources of cockroaches entering homes, adult cockroaches were collected, marked, and released into yards and sewers. No sewer-released cockroaches were collected in homes. Cockroaches released into yards were collected in the homes, suggesting that yards, rather than sewers, are a more important source niche. A field trial applying boric acid granules to the yard was performed in an effort to reduce entry of cockroaches. There was a significant reduction in the cockroach antigen collected in intervention homes compared with controls.

  14. Assessment of the contribution of sewer deposits to suspended solids loads in combined sewer systems during rain events.

    PubMed

    Hannouche, A; Chebbo, G; Joannis, C

    2014-04-01

    Within the French observatories network SOERE "URBIS," databases of continuous turbidity measurements accumulating hundreds of events and many dry weather days are available for two sites with different features (Clichy in Paris and Ecully in Lyon). These measurements, converted into total suspended solids (TSS) concentration using TSS-turbidity relationships and combined with a model of runoff event mean concentration, enable the assessment of the contribution of sewer deposits to wet weather TSS loads observed at the outlet of the two watersheds. Results show that the contribution of sewer deposits to wet weather suspended solid's discharges is important but variable (between 20 and 80 % of the mass at the outlet depending on the event), including a site allegedly free of (coarse) sewer deposits. The uncertainties associated to these results are assessed too.

  15. Impacts and managerial implications for sewer systems due to recent changes to inputs in domestic wastewater - A review.

    PubMed

    Mattsson, Jonathan; Hedström, Annelie; Ashley, Richard M; Viklander, Maria

    2015-09-15

    Ever since the advent of major sewer construction in the 1850s, the issue of increased solids deposition in sewers due to changes in domestic wastewater inputs has been frequently debated. Three recent changes considered here are the introduction of kitchen sink food waste disposers (FWDs); rising levels of inputs of fat, oil and grease (FOG); and the installation of low-flush toilets (LFTs). In this review these changes have been examined with regard to potential solids depositional impacts on sewer systems and the managerial implications. The review indicates that each of the changes has the potential to cause an increase in solids deposition in sewers and this is likely to be more pronounced for the upstream reaches of networks that serve fewer households than the downstream parts and for specific sewer features such as sags. The review has highlighted the importance of educational campaigns directed to the public to mitigate deposition as many of the observed problems have been linked to domestic behaviour in regard to FOGs, FWDs and toilet flushing. A standardized monitoring procedure of repeat sewer blockage locations can also be a means to identify depositional hot-spots. Interactions between the various changes in inputs in the studies reviewed here indicated an increased potential for blockage formation, but this would need to be further substantiated. As the precise nature of these changes in inputs have been found to be variable, depending on lifestyles and type of installation, the additional problems that may arise pose particular challenges to sewer operators and managers because of the difficulty in generalizing the nature of the changes, particularly where retrofitting projects in households are being considered. The three types of changes to inputs reviewed here highlight the need to consider whether or not more or less solid waste from households should be diverted into sewers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. A dynamic ventilation model for gravity sewer networks.

    PubMed

    Wang, Y C; Nobi, N; Nguyen, T; Vorreiter, L

    2012-01-01

    To implement any effective odour and corrosion control technology in the sewer network, it is imperative that the airflow through gravity sewer airspaces be quantified. This paper presents a full dynamic airflow model for gravity sewer systems. The model, which is developed using the finite element method, is a compressible air transport model. The model has been applied to the North Head Sewerage Ocean Outfall System (NSOOS) and calibrated using the air pressure and airflow data collected during October 2008. Although the calibration is focused on forced ventilation, the model can be applied to natural ventilation as well.

  17. A combined model to assess technical and economic consequences of changing conditions and management options for wastewater utilities.

    PubMed

    Giessler, Mathias; Tränckner, Jens

    2018-02-01

    The paper presents a simplified model that quantifies economic and technical consequences of changing conditions in wastewater systems on utility level. It has been developed based on data from stakeholders and ministries, collected by a survey that determined resulting effects and adapted measures. The model comprises all substantial cost relevant assets and activities of a typical German wastewater utility. It consists of three modules: i) Sewer for describing the state development of sewer systems, ii) WWTP for process parameter consideration of waste water treatment plants (WWTP) and iii) Cost Accounting for calculation of expenses in the cost categories and resulting charges. Validity and accuracy of this model was verified by using historical data from an exemplary wastewater utility. Calculated process as well as economic parameters shows a high accuracy compared to measured parameters and given expenses. Thus, the model is proposed to support strategic, process oriented decision making on utility level. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Modelling total suspended solids, E. coli and carbamazepine, a tracer of wastewater contamination from combined sewer overflows

    NASA Astrophysics Data System (ADS)

    Pongmala, Khemngeun; Autixier, Laurène; Madoux-Humery, Anne-Sophie; Fuamba, Musandji; Galarneau, Martine; Sauvé, Sébastien; Prévost, Michèle; Dorner, Sarah

    2015-12-01

    Urban source water protection requires knowledge of sources of fecal contamination upstream of drinking water intakes. Combined and sanitary sewer overflows (CSOs and SSOs) are primary sources of microbiological contamination and wastewater micropollutants (WWMPs) in urban water supplies. To quantify the impact of sewer overflows, predictive simulation models are required and have not been widely applied for microbial contaminants such as fecal indicator bacteria and pathogens in urban drainage networks. The objective of this study was to apply a simulation model to estimate the dynamics of three contaminants in sewer overflows - total suspended solids, Escherichia coli (E. coli) and carbamazepine, a WWMP. A mixed combined and pseudo-sanitary drainage network in Québec, Canada was studied and modelled for a total of 7 events for which water quality data were available. Model results were significantly correlated with field water quality data. The model confirmed that the contributions of E. coli from runoff and sewer deposits were minor and their dominant source was from sewage. In contrast, the main sources of total suspended solids were stormwater runoff and sewer resuspension. Given that it is not present in stormwater, carbamazepine was found to be a useful stable tracer of sewage contributions to total contaminant loads and also provided an indication of the fraction of total suspended solids originating from sewer deposits because of its similar response to increasing flowrates.

  19. 243 E. Ontario Street - Sewer, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    The field gamma measurements within the excavation during the excavation process did not exceed theinstrument threshold previously stated, and ranged from a minimum of 1,100 cpm to a maximum of 3,600cpm shielded.

  20. An analytical probabilistic model of the quality efficiency of a sewer tank

    NASA Astrophysics Data System (ADS)

    Balistrocchi, Matteo; Grossi, Giovanna; Bacchi, Baldassare

    2009-12-01

    The assessment of the efficiency of a storm water storage facility devoted to the sewer overflow control in urban areas strictly depends on the ability to model the main features of the rainfall-runoff routing process and the related wet weather pollution delivery. In this paper the possibility of applying the analytical probabilistic approach for developing a tank design method, whose potentials are similar to the continuous simulations, is proved. In the model derivation the quality issues of such devices were implemented. The formulation is based on a Weibull probabilistic model of the main characteristics of the rainfall process and on a power law describing the relationship between the dimensionless storm water cumulative runoff volume and the dimensionless cumulative pollutograph. Following this approach, efficiency indexes were established. The proposed model was verified by comparing its results to those obtained by continuous simulations; satisfactory agreement is shown for the proposed efficiency indexes.

  1. 75 FR 5788 - Notice of Availability of Draft National Pollutant Discharge Elimination System (NPDES) General...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-04

    ... Discharge Elimination System (NPDES) General Permits for Small Municipal Separate Storm Sewer Systems (MS4... at 40 CFR 122.26(b)(16) define a small municipal separate storm sewer system as ``* * * all separate storm sewers that are: (1) Owned or operated by the United States, a State, city, town, borough, county...

  2. Characterization of runoff from various urban catchments at different spatial scales in Beijing, China.

    PubMed

    Zhang, W; Che, W; Liu, D K; Gan, Y P; Lv, F F

    2012-01-01

    In order to investigate the characterization of runoff in storm sewer from various urban catchments, three monitoring systems at different spatial scales have been installed separately. They have been held since July 2010 in urban area of Beijing (China). The monitoring data revealed that chemical oxygen demand (COD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP), and NH(3)-N values significantly exceed the Class V surface water quality standard developed by Ministry of Environmental Protection of the People's Republic of China (MEP). A surface solids buildup and wash off model for small watershed was adopted to analyze and discuss the process of a runoff pollutant discharge. More than a half of pollutant parameters presented a good fit to the model. However, a slightly worse-fit to the wash off model appeared in less than half of the data. Due to the influence of sewer sediments, sewer system characteristics, catchment characteristics, and other reasons, first flush was seldom observed in storm sewer runoff from these three survey areas. Meanwhile, the correlation between TSS and any other pollutant was analyzed according to cumulative load of pollutants in runoff events. An event mean concentrations (EMCs) approach was adopted to quantify the pollution of runoff. EMCs of various pollutants in storm sewer runoff between different rainfall events were slightly higher than the typical values observed in similar areas at home and abroad, according to other studies reported in literature. Based on quantitative analysis, it can be concluded that urban non-point source pollution is recognized as the major causes of quality deterioration in the receiving water bodies. This is after the point source pollution has been controlled substantially in Beijing. An integrated strategy, which combines centralized and decentralized control, along with the conditions of meteorology, hydrology, urban planning, existing drainage system, etc., will be an effective and economic approach to urban runoff pollution control.

  3. Evaluating rain gardens as a method to reduce the impact of sewer overflows in sources of drinking water.

    PubMed

    Autixier, Laurène; Mailhot, Alain; Bolduc, Samuel; Madoux-Humery, Anne-Sophie; Galarneau, Martine; Prévost, Michèle; Dorner, Sarah

    2014-11-15

    The implications of climate change and changing precipitation patterns need to be investigated to evaluate mitigation measures for source water protection. Potential solutions need first to be evaluated under present climate conditions to determine their utility as climate change adaptation strategies. An urban drainage network receiving both stormwater and wastewater was studied to evaluate potential solutions to reduce the impact of combined sewer overflows (CSOs) in a drinking water source. A detailed hydraulic model was applied to the drainage basin to model the implementation of best management practices at a drainage basin scale. The model was calibrated and validated with field data of CSO flows for seven events from a survey conducted in 2009 and 2010. Rain gardens were evaluated for their reduction of volumes of water entering the drainage network and of CSOs. Scenarios with different levels of implementation were considered and evaluated. Of the total impervious area within the basin directly connected to the sewer system, a maximum of 21% could be alternately directed towards rain gardens. The runoff reductions for the entire catchment ranged from 12.7% to 19.4% depending on the event considered. The maximum discharged volume reduction ranged from 13% to 62% and the maximum peak flow rate reduction ranged from 7% to 56%. Of concern is that in-sewer sediment resuspension is an important process to consider with regard to the efficacy of best management practices aimed at reducing extreme loads and concentrations. Rain gardens were less effective for large events, which are of greater importance for drinking water sources. These practices could increase peak instantaneous loads as a result of greater in-sewer resuspension during large events. Multiple interventions would be required to achieve the objectives of reducing the number, total volumes and peak contaminant loads of overflows upstream of drinking water intakes. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. On the occurrence of rainstorm damage based on home insurance and weather data

    NASA Astrophysics Data System (ADS)

    Spekkers, M. H.; Clemens, F. H. L. R.; ten Veldhuis, J. A. E.

    2014-08-01

    Rainstorm damage caused by malfunctioning of urban drainage systems and water intrusion due to defects in the building envelope can be considerable. Little research on this topic focused on the collection of damage data, the understanding of damage mechanisms and the deepening of data analysis methods. In this paper, the relative contribution of different failure mechanisms to the occurrence of rainstorm damage are investigated, as well as the extent to which these mechanisms relate to weather variables. For a case study in Rotterdam, the Netherlands, a property level home insurance database of around 3100 water-related damage claims was analysed. Records include comprehensive transcripts of communication between insurer, insured and damage assessment experts, which allowed claims to be classified according to their actual damage cause. Results show that roof and wall leakage is the most frequent failure mechanism causing precipitation-related claims, followed by blocked roof gutters, melting snow and sewer flooding. Claims related to sewer flooding were less present in the data, but are associated with significantly larger claim sizes than claims in the majority class, i.e. roof and wall leakages. Rare events logistic regression analysis revealed that maximum rainfall intensity and rainfall volume are significant predictors for the occurrence probability of precipitation-related claims. Moreover, it was found that claims associated with rainfall intensities smaller than 7-8 mm in a 60 min window are mainly related to failures processes in the private domain, such as roof and wall leakages. For rainfall events that exceed the 7-8 mm h-1 threshold, failure of systems in the public domain, such as sewer systems, start to contribute considerably to the overall occurrence probability of claims. The communication transcripts, however, lacked information to be conclusive about to extent to which sewer-related claims were caused by overloading of sewer systems or failure of system components.

  5. On the occurrence of rainstorm damage based on home insurance and weather data

    NASA Astrophysics Data System (ADS)

    Spekkers, M. H.; Clemens, F. H. L. R.; ten Veldhuis, J. A. E.

    2015-02-01

    Rainstorm damage caused by the malfunction of urban drainage systems and water intrusion due to defects in the building envelope can be considerable. Little research on this topic focused on the collection of damage data, the understanding of damage mechanisms and the deepening of data analysis methods. In this paper, the relative contribution of different failure mechanisms to the occurrence of rainstorm damage is investigated, as well as the extent to which these mechanisms relate to weather variables. For a case study in Rotterdam, the Netherlands, a property level home insurance database of around 3100 water-related damage claims was analysed. The records include comprehensive transcripts of communication between insurer, insured and damage assessment experts, which allowed claims to be classified according to their actual damage cause. The results show that roof and wall leakage is the most frequent failure mechanism causing precipitation-related claims, followed by blocked roof gutters, melting snow and sewer flooding. Claims related to sewer flooding were less present in the data, but are associated with significantly larger claim sizes than claims in the majority class, i.e. roof and wall leakages. Rare events logistic regression analysis revealed that maximum rainfall intensity and rainfall volume are significant predictors for the occurrence probability of precipitation-related claims. Moreover, it was found that claims associated with rainfall intensities smaller than 7-8 mm in a 60-min window are mainly related to failure processes in the private domain, such as roof and wall leakages. For rainfall events that exceed the 7-8 mm h-1 threshold, the failure of systems in the public domain, such as sewer systems, start to contribute considerably to the overall occurrence probability of claims. The communication transcripts, however, lacked information to be conclusive about to which extent sewer-related claims were caused by overloading of sewer systems or failure of system components.

  6. The utilisation of engineered invert traps in the management of near bed solids in sewer networks.

    PubMed

    Ashley, R M; Tait, S J; Stovin, V R; Burrows, R; Framer, A; Buxton, A P; Blackwood, D J; Saul, A J; Blanksby, J R

    2003-01-01

    Large existing sewers are considerable assets which wastewater utilities will require to operate for the foreseeable future to maintain health and the quality of life in cities. Despite their existence for more than a century there is surprisingly little guidance available to manage these systems to minimise problems associated with in-sewer solids. A joint study has been undertaken in the UK, to refine and utilise new knowledge gained from field data, laboratory results and Computational Fluid Dynamics (CFD) simulations to devise cost beneficial engineering tools for the application of small invert traps to localise the deposition of sediments in sewers at accessible points for collection. New guidance has been produced for trap siting and this has been linked to a risk-cost-effectiveness assessment procedure to enable system operators to approach in-sewer sediment management pro-actively rather than reactively as currently happens.

  7. RTC simulations on large branched sewer systems with SmaRTControl.

    PubMed

    de Korte, Kees; van Beest, Dick; van der Plaat, Marcel; de Graaf, Erno; Schaart, Niels

    2009-01-01

    In The Netherlands many large branched sewer systems exist. RTC can improve the performance of these systems. The objective of the universal algorithm of SmaRTControl is to improve the performance of the sewer system and the WWTP. The effect of RTC under rain weather flow conditions is simulated using a hydrological model with 19 drainage districts. The system related inefficiency coefficient (SIC) is introduced for assessment of the performance of sewer systems. The performance can be improved by RTC in combination with increased pumping capacities in the drainage districts, but without increasing the flow to the WWTP. Under dry weather flow conditions the flow to the WWTP can be equalized by storage of wastewater in the sewer system. It is concluded that SmaRTControl can improve the performance, that simulations are necessary and that SIC is an excellent parameter for assessment of the performance.

  8. 40 CFR 63.1094 - What waste streams are exempt from the requirements of this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CATEGORIES (CONTINUED) National Emission Standards for Ethylene Manufacturing Process Units: Heat Exchange... section are exempt from this subpart. (a) Waste in the form of gases or vapors that is emitted from process fluids. (b) Waste that is contained in a segregated storm water sewer system. Waste Requirements ...

  9. Integrating retention soil filters into urban hydrologic models - Relevant processes and important parameters

    NASA Astrophysics Data System (ADS)

    Bachmann-Machnik, Anna; Meyer, Daniel; Waldhoff, Axel; Fuchs, Stephan; Dittmer, Ulrich

    2018-04-01

    Retention Soil Filters (RSFs), a form of vertical flow constructed wetlands specifically designed for combined sewer overflow (CSO) treatment, have proven to be an effective tool to mitigate negative impacts of CSOs on receiving water bodies. Long-term hydrologic simulations are used to predict the emissions from urban drainage systems during planning of stormwater management measures. So far no universally accepted model for RSF simulation exists. When simulating hydraulics and water quality in RSFs, an appropriate level of detail must be chosen for reasonable balancing between model complexity and model handling, considering the model input's level of uncertainty. The most crucial parameters determining the resultant uncertainties of the integrated sewer system and filter bed model were identified by evaluating a virtual drainage system with a Retention Soil Filter for CSO treatment. To determine reasonable parameter ranges for RSF simulations, data of 207 events from six full-scale RSF plants in Germany were analyzed. Data evaluation shows that even though different plants with varying loading and operation modes were examined, a simple model is sufficient to assess relevant suspended solids (SS), chemical oxygen demand (COD) and NH4 emissions from RSFs. Two conceptual RSF models with different degrees of complexity were assessed. These models were developed based on evaluation of data from full scale RSF plants and column experiments. Incorporated model processes are ammonium adsorption in the filter layer and degradation during subsequent dry weather period, filtration of SS and particulate COD (XCOD) to a constant background concentration and removal of solute COD (SCOD) by a constant removal rate during filter passage as well as sedimentation of SS and XCOD in the filter overflow. XCOD, SS and ammonium loads as well as ammonium concentration peaks are discharged primarily via RSF overflow not passing through the filter bed. Uncertainties of the integrated simulation of the sewer system and RSF model mainly originate from the model parameters of the hydrologic sewer system model.

  10. 75 FR 67960 - Notice of Availability of Draft National Pollutant Discharge Elimination System (NPDES) General...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-04

    ... Discharge Elimination System (NPDES) General Permits for Small Municipal Separate Storm Sewer Systems (MS4... requirements of the CWA. The regulations at 40 CFR 122.26(b)(16) define a small municipal separate storm sewer system as ``* * * all separate storm sewers that are: (1) Owned or operated by the United States, a State...

  11. Hydrocarbon pollution fixed to combined sewer sediment: a case study in Paris.

    PubMed

    Rocher, Vincent; Garnaud, Stéphane; Moilleron, Régis; Chebbo, Ghassan

    2004-02-01

    Over a period of two years (2000-2001), sediment samples were extracted from 40 silt traps (STs) spread through the combined sewer system of Paris. All sediment samples were analysed for physico-chemical parameters (pH, organic matter content, grain size distribution), with total hydrocarbons (THs) and 16 polycyclic aromatic hydrocarbons (PAHs) selected from the priority list of the US-EPA. The two main objectives of the study were (1) to determine the hydrocarbon contamination levels in the sediments of the Paris combined sewer system and (2) to investigate the PAH fingerprints in order to assess their spatial variability and to elucidate the PAH origins. The results show that there is some important inter-site and intra-site variations in hydrocarbon contents. Despite this variability, TH and PAH contamination levels (50th percentile) in the Parisian sewer sediment are estimated at 530 and 18 microg g(-1), respectively. The investigation of the aromatic compound distributions in all of the 40 STs has underlined that there is, at the Paris sewer system scale, a homogeneous PAH background pollution. Moreover, the study of the PAH fingerprints, using specific ratios, suggests the predominance of a pyrolytic origin for those PAHs fixed to the sewer sediment.

  12. Stable isotopes of water as a natural tracer for infiltration into urban sewer systems

    NASA Astrophysics Data System (ADS)

    Kracht, O.; Gresch, M.; de Bénédittis, J.; Prigiobbe, V.; Gujer, W.

    2003-04-01

    An adequate understanding of the hydraulic interaction between leaky sewers and groundwater is essential for the sustainable management of both sewer systems and aquifers in urbanized areas. Undesirable infiltration of groundwater into sewers can contribute over 50% of the total discharge and is detrimental to treatment plant efficiency. On the other hand, in many European cities groundwater surface levels seem to be particularly controlled by the drainage effect of permeable sewer systems. However, nowadays methods for the quantification of these exchange processes are still subject to considerable uncertainties due to their underlying assumptions. The frequently used assumption that the night time minimum in the diurnal wastewater hydrograph is equal to the "parasitic discharge" has to be reconsidered to today's patterns of human life as well as to the long residence time of wastewater in the sewer networks of modern cities. The suitability of stable water isotopes as a natural tracer to differentiate the origin of water in the sewer ("real" wastewater or infiltrating groundwater) is currently investigated in three different catchment areas. The studies are carried out within the framework of the European research project APUSS (Assessing Infiltration and Exfiltration on the Performance of Urban Sewer Systems): 1) The village of Rümlang (Zürich, Switzerland) is predominantly served with drinking water from the Lake Zürich. A large fraction of the lakes water is derived from precipitation in the Alps. This drinking water represents the intrinsic provenience of the wastewater with an δ18O value around -11,5 per mill and δ^2H value around -82 per mill vs. SMOW. In contrast, the local groundwater is originating from precipitation in a moderate altitude of about 450 m above sea level and shows comparatively enriched mean δ18O values of -9,7 per mill and δ^2H values of -70 per mill with only small natural variations. The isotopic separation between these endmembers is basically sufficient to estimate the ratio of infiltrating water in the sewer. Uncertainties yet derive from varying amounts of local groundwater in the water supply mains. These will be substituted by additionally purchased lake water in the next experimental stage. 2) The experimental site Toraccia (suburb of Rome, Italy) obtains drinking water from the Peschiera springs group that is situated in the central Apennines chain about 90 km north east of Rome. This spring water is transported to Rome by an aqueduct. A first campaign revealed an average mains water δ18O value of -8,4 per mill and δ^2H value of -53 per mill. Potential sources of infiltration are occurrences of perched groundwater. These appear to be enriched compared to the drinking water about 2 to 3 per mill in the δ18O and 10 to 20 per mill in the δ^2H value, but show disadvantageous strong variations. 3) Investigations in the urban area of Lyon (France) benefit from the isotopic differences between underground waters originating from the two rivers Rhone and Saone and their associated alluvial aquifers. The oxygen isotope composition of the Rhone water is roughly 3 per mill lighter than that of the river Saone, due to the large differences in the mean altitude and topographic situation of their catchment basins. Considerable amounts of mains water are extracted by production wells in the Rhone aquifer. In consequence a usable difference in the oxygen isotope composition between wastewater and local groundwater of about 1.5 per mill is available for application studies in certain parts of the city.

  13. Hydrogeology and groundwater quality at monitoring wells installed for the Tunnel and Reservoir Plan System and nearby water-supply wells, Cook County, Illinois, 1995–2013

    USGS Publications Warehouse

    Kay, Robert T.

    2016-04-04

    Groundwater-quality data collected from 1995 through 2013 from 106 monitoring wells open to the base of the Silurian aquifer surrounding the Tunnel and Reservoir Plan (TARP) System in Cook County, Illinois, were analyzed by the U.S. Geological Survey, in cooperation with the Metropolitan Water Reclamation District of Greater Chicago, to assess the efficacy of the monitoring network and the effects of water movement from the tunnel system to the surrounding aquifer. Groundwater from the Silurian aquifer typically drains to the tunnel system so that analyte concentrations in most of the samples from most of the monitoring wells primarily reflect the concentration of the analyte in the nearby Silurian aquifer. Water quality in the Silurian aquifer is spatially variable because of a variety of natural and non-TARP anthropogenic processes. Therefore, the trends in analyte values at a given well from 1995 through 2013 are primarily a reflection of the spatial variation in the value of the analyte in groundwater within that part of the Silurian aquifer draining to the tunnels. Intermittent drainage of combined sewer flow from the tunnel system to the Silurian aquifer when flow in the tunnel systemis greater than 80 million gallons per day may affect water quality in some nearby monitoring wells. Intermittent drainage of combined sewer flow from the tunnel system to the Silurian aquifer appears to affect the values of electrical conductivity, hardness, sulfate, chloride, dissolved organic carbon, ammonia, and fecal coliform in samples from many wells but typically during less than 5 percent of the sampling events. Drainage of combined sewer flow into the aquifer is most prevalent in the downstream parts of the tunnel systems because of the hydraulic pressures elevated above background values and long residence time of combined sewer flow in those areas. Elevated values of the analytes emplaced during intermittent migration of combined sewer flow into the Silurian aquifer decrease through time as water from the aquifer drains back into the tunnels in response to typical hydraulic conditions. Of the analytes sampled, fecal coliform provides the clearest indication of the location and timing of combined sewer flow into the Silurian aquifer surrounding the tunnel system.

  14. The hydraulic capacity of deteriorating sewer systems.

    PubMed

    Pollert, J; Ugarelli, R; Saegrov, S; Schilling, W; Di Federico, V

    2005-01-01

    Sewer and wastewater systems suffer from insufficient capacity, construction flaws and pipe deterioration. Consequences are structural failures, local floods, surface erosion and pollution of receiving waters bodies. European cities spend in the order of five billion Euro per year for wastewater network rehabilitation. This amount is estimated to increase due to network ageing. The project CARE-S (Computer Aided RE-habilitation of Sewer Networks) deals with sewer and storm water networks. The final project goal is to develop integrated software, which provides the most cost-efficient system of maintenance, repair and rehabilitation of sewer networks. Decisions on investments in rehabilitation often have to be made with uncertain information about the structural condition and the hydraulic performance of a sewer system. Because of this, decision-making involves considerable risks. This paper presents the results of research focused on the study of hydraulic effects caused by failures due to temporal decline of sewer systems. Hydraulic simulations are usually carried out by running commercial models that apply, as input, default values of parameters that strongly influence results. Using CCTV inspections information as dataset to catalogue principal types of failures affecting pipes, a 3D model was used to evaluate their hydraulic consequences. The translation of failures effects in parameters values producing the same hydraulic conditions caused by failures was carried out through the comparison of laboratory experiences and 3D simulations results. Those parameters could be the input of 1D commercial models instead of the default values commonly inserted.

  15. Separate and combined sewer systems: a long-term modelling approach.

    PubMed

    Mannina, Giorgio; Viviani, Gaspare

    2009-01-01

    Sewer systems convey mostly dry weather flow, coming from domestic and industrial sanitary sewage as well as infiltration flow, and stormwater due to meteoric precipitations. Traditionally, in urban drainage two types of sewer systems are adopted: separate and combined sewers. The former convey dry and wet weather flow separately into two different networks, while the latter convey dry and wet weather flow together. Which is the best solution in terms of cost-benefit analysis still remains a controversial subject. The present study was aimed at comparing the pollution loads discharged to receiving bodies by Wastewater Treatment Plant (WWTP) and Combined Sewer Overflow (CSO) for different kinds of sewer systems (combined and separate). To accomplish this objective, a comparison between the two systems was carried out using results from simulations of catchments characterised by different dimensions, population densities and water supply rate. The analysis was based on a parsimonious mathematical model able to simulate the sewer system as well as the WWTP during both dry and wet weather. The rain series employed for the simulations was six years long. Several pollutants, both dissolved and particulate, were modelled. The results confirmed the uncertainties in the choice of one system versus the other, emphasising the concept that case-by-case solutions have to be undertaken. Further, the compared systems showed different responses in terms of effectiveness in reducing the discharged mass to the RWB in relation to the particular pollutant taken into account.

  16. Smart Water Conservation System for Irrigated Landscape

    DTIC Science & Technology

    2016-05-01

    purple pipe indicating reuse water) and properly labeled “not for human consumption”; • Do not connect rainwater overflow discharge to sanitary sewer...Report Smart Water Conservation System 75 May 2016 Condensate Capture If redirecting condensate from sanitary sewer, ensure sewer gases are managed...the spring/early summer to determine optimum irrigation safety factor. Irrigate at night or early morning. Set soak and cycle for clay soils. ET

  17. State waste discharge permit application: 200 Area Treated Effluent Disposal Facility (Project W-049H)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-08-01

    As part of the original Hanford Federal Facility Agreement and Concent Order negotiations, US DOE, US EPA and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground to the Hanford Site are subject to permitting in the State Waste Discharge Permit Program (SWDP). This document constitutes the SWDP Application for the 200 Area TEDF stream which includes the following streams discharged into the area: Plutonium Finishing Plant waste water; 222-S laboratory Complex waste water; T Plant waste water; 284-W Power Plant waste water; PUREX chemical Sewer; B Plant chemical sewer, process condensate, steam condensate; 242-A-81more » Water Services waste water.« less

  18. Comparison of different synthetic 5-min rainfall time series on the results of rainfall runoff simulations in urban drainage modelling

    NASA Astrophysics Data System (ADS)

    Krämer, Stefan; Rohde, Sophia; Schröder, Kai; Belli, Aslan; Maßmann, Stefanie; Schönfeld, Martin; Henkel, Erik; Fuchs, Lothar

    2015-04-01

    The design of urban drainage systems with numerical simulation models requires long, continuous rainfall time series with high temporal resolution. However, suitable observed time series are rare. As a result, usual design concepts often use uncertain or unsuitable rainfall data, which renders them uneconomic or unsustainable. An expedient alternative to observed data is the use of long, synthetic rainfall time series as input for the simulation models. Within the project SYNOPSE, several different methods to generate synthetic rainfall data as input for urban drainage modelling are advanced, tested, and compared. Synthetic rainfall time series of three different precipitation model approaches, - one parametric stochastic model (alternating renewal approach), one non-parametric stochastic model (resampling approach), one downscaling approach from a regional climate model-, are provided for three catchments with different sewer system characteristics in different climate regions in Germany: - Hamburg (northern Germany): maritime climate, mean annual rainfall: 770 mm; combined sewer system length: 1.729 km (City center of Hamburg), storm water sewer system length (Hamburg Harburg): 168 km - Brunswick (Lower Saxony, northern Germany): transitional climate from maritime to continental, mean annual rainfall: 618 mm; sewer system length: 278 km, connected impervious area: 379 ha, height difference: 27 m - Friburg in Brisgau (southern Germany): Central European transitional climate, mean annual rainfall: 908 mm; sewer system length: 794 km, connected impervious area: 1 546 ha, height difference 284 m Hydrodynamic models are set up for each catchment to simulate rainfall runoff processes in the sewer systems. Long term event time series are extracted from the - three different synthetic rainfall time series (comprising up to 600 years continuous rainfall) provided for each catchment and - observed gauge rainfall (reference rainfall) according national hydraulic design standards. The synthetic and reference long term event time series are used as rainfall input for the hydrodynamic sewer models. For comparison of the synthetic rainfall time series against the reference rainfall and against each other the number of - surcharged manholes, - surcharges per manhole, - and the average surcharge volume per manhole are applied as hydraulic performance criteria. The results are discussed and assessed to answer the following questions: - Are the synthetic rainfall approaches suitable to generate high resolution rainfall series and do they produce, - in combination with numerical rainfall runoff models - valid results for design of urban drainage systems? - What are the bounds of uncertainty in the runoff results depending on the synthetic rainfall model and on the climate region? The work is carried out within the SYNOPSE project, funded by the German Federal Ministry of Education and Research (BMBF).

  19. Sewer Project Remedies ‘Third World’ Conditions

    EPA Pesticide Factsheets

    An EPA-funded project to process sewage from homes on a West Virginia hillside has resolved what a county health department report described as “Third World” conditions caused by failing or non-existent on-site systems to manage human waste.

  20. Quality of Wisconsin stormwater, 1989-94

    USGS Publications Warehouse

    Bannerman, Roger T.; Legg, Andrew D.; Greb, Steven R.

    1996-01-01

    Water-quality data were compiled from four urban stormwater monitoring projects conducted in Wisconsin between 1989 and 1994. These projects included monitoring in both storm-sewer pipes and urban streams. A total of 147 constitu ents were analyzed for in stormwater sampled from 10 storm-sewer pipes and four urban streams. Land uses represented by the storm-sewer watersheds included residential, commercial, industrial, and mixed. For about one-half the con stituents, at least 10 percent of the event mean con centrations exceeded the laboratory's minimum reporting limit. Detection frequencies were greater than 75 percent for many of the heavy metals and polycyclic aromatic hydrocarbons in both the storm sewer and stream samples, whereas detec tion frequencies were about 20 percent or greater for many of the pesticides in both types of sam ples. Stormwater concentrations for conventional constituents, such as suspended solids, chloride, total phosphorus, and fecal coliform bacteria were greater than minimum reporting limits almost 100 percent of the time. Concentrations of many of the constituents were high enough to say that stormwater in the storm sewers and urban streams might be contrib uting to the degradation of the streams. In this report, constituents defined as potential contami nants are those for which the laboratory minimum report limit was exceeded for at least 10 percent of the sampled storm events, and for which at least one event mean concentration exceeded an estab lished water-quality standard. Storm-sewer sam ples had event mean concentrations of lead, copper, zinc, cadmium, and silver that frequently exceeded Wisconsin's acute toxicity criteria for cold water fisheries. Wisconsin's human cancer criteria was exceeded almost 100 percent of the time for polycyclic aromatic hydrocarbons in stormwater samples from storm sewers and streams. Maximum concentrations of diazinon found in storm sewers exceeded recommended levels of diazinon. Storm-sewer samples also exceeded Wisconsin's ground-water enforcement standards for pesticides, PCB's, phthalates, and chloride. Defined by criteria in this report, poten tial contaminants included five metals (lead, zinc, copper, silver, and cadmium), nine polycyclic aro matic hydrocarbons, Bis(2-ethylhexyl)phthalate, four pesticides (DDT, atrazine, alachlor, and 2,4 D), suspended solids, chlorides, total phosphorus, BOD 5-day, and bacteria. Wisconsin stormwater quality was similar to stormwater quality monitored in other states. Nearly one-half of median concentrations of con stituents in Wisconsin stormwater were within 30 percent of the medians from other states. The clos est agreement was seen for biochemical oxygen demand, total phosphorus, and total recoverable zinc. Similarities in stormwater quality for the storm sewer and urban streams indicated the storm sewers were a major source of water to the streams during storm events. Concentrations of potential contaminants in urban streams increased dramati cally during storm events as compared to baseflow concentrations.

  1. Dynamics of pollutant discharge in combined sewer systems during rain events: chance or determinism?

    PubMed

    Hannouche, A; Chebbo, G; Joannis, C

    2014-01-01

    A large database of continuous flow and turbidity measurements cumulating data on hundreds of rain events and dry weather days from two sites in Paris (called Quais and Clichy) and one in Lyon (called Ecully) is presented. This database is used to characterize and compare the behaviour of the three sites at the inter-events scale. The analysis is probed through three various variables: total volumes and total suspended solids (TSS) masses and concentrations during both wet and dry weather periods in addition to the contributions of diverse-origin sources to event flow volume and TSS load values. The results obtained confirm the previous findings regarding the spatial consistency of TSS fluxes and concentrations between both sites in Paris having similar land uses. Moreover, masses and concentrations are proven to be correlated between Parisian sites in a way that implies the possibility of some deterministic processes being reproducible from one catchment to another for a particular rain event. The results also demonstrate the importance of the contribution of wastewater and sewer deposits to the total events' loads and show that such contributions are not specific to Paris sewer networks.

  2. Predicting the Probability of Failure of Cementitious Sewer Pipes Using Stochastic Finite Element Method

    PubMed Central

    Alani, Amir M.; Faramarzi, Asaad

    2015-01-01

    In this paper, a stochastic finite element method (SFEM) is employed to investigate the probability of failure of cementitious buried sewer pipes subjected to combined effect of corrosion and stresses. A non-linear time-dependant model is used to determine the extent of concrete corrosion. Using the SFEM, the effects of different random variables, including loads, pipe material, and corrosion on the remaining safe life of the cementitious sewer pipes are explored. A numerical example is presented to demonstrate the merit of the proposed SFEM in evaluating the effects of the contributing parameters upon the probability of failure of cementitious sewer pipes. The developed SFEM offers many advantages over traditional probabilistic techniques since it does not use any empirical equations in order to determine failure of pipes. The results of the SFEM can help the concerning industry (e.g., water companies) to better plan their resources by providing accurate prediction for the remaining safe life of cementitious sewer pipes. PMID:26068092

  3. Suitable flow pattern increases the removal efficiency of nitrogen in gravity sewers: a suitable anoxic and aerobic environment in biofilms.

    PubMed

    He, Qiang; Yin, Feixian; Li, Hong; Wang, Yinliang; Xu, Jingwei; Ai, Hainan

    2018-03-25

    The sewers have the function of carbon removal, which has been proven. But if the effect of nitrogen removal can be enhanced at the same time of carbon removal, it can lay a foundation for the realization of "sewer's working as a reactor." This paper investigated the effects of shear stress and C/N ratio on nitrogen removal through biofilms on the sewer inner wall and nitrogen transfer. The main conclusions are as follows: (1) nitrogen could be partially removed in sewers after a series of reactions; (2) the anaerobic, anoxic, aerobic environment and some bacteria related to nitrogen metabolism, which exist in the biofilm, promote the nitrification and denitrification; (3) a total of 722 functional genes involved in nitrogen metabolism were detected in the biofilm (C/N ratio of 10, shear stress of 1.4 Pa), accounting for 0.67% of all genes, and the functional genes related to denitrification were dominant. Graphical abstract ᅟ.

  4. Space-Derived Sewer Monitor

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The QuadraScan Longterm Flow Monitoring System is a second generation sewer monitor developed by American Digital Systems, Inc.'s founder Peter Petroff. Petroff, a former spacecraft instrumentation designer at Marshall Space Flight Center, used expertise based on principles acquired in Apollo and other NASA programs. QuadraScan borrows even more heavily from space technology, for example in its data acquisition and memory system derived from NASA satellites. "One-time" measurements are often plagued with substantial errors due to the flow of groundwater absorbed into the system. These system sizing errors stem from a basic informational deficiency: accurate, reliable data on how much water flows through a sewer system over a long period of time is very difficult to obtain. City officials are turning to "permanent," or long-term sewer monitoring systems. QuadraScan offers many advantages to city officials such as the early warning capability to effectively plan for city growth in order to avoid the crippling economic impact of bans on new sewer connections in effect in many cities today.

  5. A generic methodology for the optimisation of sewer systems using stochastic programming and self-optimizing control.

    PubMed

    Mauricio-Iglesias, Miguel; Montero-Castro, Ignacio; Mollerup, Ane L; Sin, Gürkan

    2015-05-15

    The design of sewer system control is a complex task given the large size of the sewer networks, the transient dynamics of the water flow and the stochastic nature of rainfall. This contribution presents a generic methodology for the design of a self-optimising controller in sewer systems. Such controller is aimed at keeping the system close to the optimal performance, thanks to an optimal selection of controlled variables. The definition of an optimal performance was carried out by a two-stage optimisation (stochastic and deterministic) to take into account both the overflow during the current rain event as well as the expected overflow given the probability of a future rain event. The methodology is successfully applied to design an optimising control strategy for a subcatchment area in Copenhagen. The results are promising and expected to contribute to the advance of the operation and control problem of sewer systems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Output-feedback control of combined sewer networks through receding horizon control with moving horizon estimation

    NASA Astrophysics Data System (ADS)

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2015-10-01

    An output-feedback control strategy for pollution mitigation in combined sewer networks is presented. The proposed strategy provides means to apply model-based predictive control to large-scale sewer networks, in-spite of the lack of measurements at most of the network sewers. In previous works, the authors presented a hybrid linear control-oriented model for sewer networks together with the formulation of Optimal Control Problems (OCP) and State Estimation Problems (SEP). By iteratively solving these problems, preliminary Receding Horizon Control with Moving Horizon Estimation (RHC/MHE) results, based on flow measurements, were also obtained. In this work, the RHC/MHE algorithm has been extended to take into account both flow and water level measurements and the resulting control loop has been extensively simulated to assess the system performance according different measurement availability scenarios and rain events. All simulations have been carried out using a detailed physically based model of a real case-study network as virtual reality.

  7. Impact of in-Sewer Degradation of Pharmaceutical and Personal Care Products (PPCPs) Population Markers on a Population Model.

    PubMed

    O'Brien, Jake William; Banks, Andrew Phillip William; Novic, Andrew Joseph; Mueller, Jochen F; Jiang, Guangming; Ort, Christoph; Eaglesham, Geoff; Yuan, Zhiguo; Thai, Phong K

    2017-04-04

    A key uncertainty of wastewater-based epidemiology is the size of the population which contributed to a given wastewater sample. We previously developed and validated a Bayesian inference model to estimate population size based on 14 population markers which: (1) are easily measured and (2) have mass loads which correlate with population size. However, the potential uncertainty of the model prediction due to in-sewer degradation of these markers was not evaluated. In this study, we addressed this gap by testing their stability under sewer conditions and assessed whether degradation impacts the model estimates. Five markers, which formed the core of our model, were stable in the sewers while the others were not. Our evaluation showed that the presence of unstable population markers in the model did not decrease the precision of the population estimates providing that stable markers such as acesulfame remained in the model. However, to achieve the minimum uncertainty in population estimates, we propose that the core markers to be included in population models for other sites should meet two additional criteria: (3) negligible degradation in wastewater to ensure the stability of chemicals during collection; and (4) < 10% in-sewer degradation could occur during the mean residence time of the sewer network.

  8. Understanding the spatial formation and accumulation of fats, oils and grease deposits in the sewer collection system.

    PubMed

    Dominic, Christopher Cyril Sandeep; Szakasits, Megan; Dean, Lisa O; Ducoste, Joel J

    2013-01-01

    Sanitary sewer overflows are caused by the accumulation of insoluble calcium salts of fatty acids, which are formed by the reaction between fats, oils and grease (FOG) and calcium found in wastewaters. Different sewer structural configurations (i.e., manholes, pipes, wet wells), which vary spatially, along with other obstructions (roots intrusion) and pipe deformations (pipe sags), may influence the detrimental buildup of FOG deposits. The purpose of this study was to quantify the spatial variation in FOG deposit formation and accumulation in a pilot-scale sewer collection system. The pilot system contained straight pipes, manholes, roots intrusion, and a pipe sag. Calcium and oil were injected into the system and operated at alkaline (pH = 10) and neutral (pH = 7) pH conditions. Results showed that solid accumulations were slightly higher at neutral pH. Fourier transform infrared (FTIR) analysis on the solids samples confirmed that the solids were indeed calcium-based fatty acid salts. However, the fatty acid profiles of the solids deviated from the profile found from FOG deposits in sewer systems, which were primarily saturated fatty acids. These results confirm the work done previously by researchers and suggest an alternative fate of unsaturated fatty acids that does not lead to their incorporation in FOG deposits in full-scale sewer systems.

  9. Storm water management in an urban catchment: effects of source control and real-time management of sewer systems on receiving water quality.

    PubMed

    Frehmann, T; Nafo, I; Niemann, A; Geiger, W F

    2002-01-01

    For the examination of the effects of different storm water management strategies in an urban catchment area on receiving water quality, an integrated simulation of the sewer system, wastewater treatment plant and receiving water is carried out. In the sewer system real-time control measures are implemented. As examples of source control measures the reduction of wastewater and the reduction of the amount of impervious surfaces producing storm water discharges are examined. The surface runoff calculation and the simulation of the sewer system and the WWTP are based on a MATLAB/SIMULINK simulation environment. The impact of the measures on the receiving water is simulated using AQUASIM. It can be shown that the examined storm water management measures, especially the source control measures, can reduce the combined sewer overflow volume and the pollutant discharge load considerably. All examined measures also have positive effects on the receiving water quality. Moreover, the reduction of impervious surfaces avoids combined sewer overflow activities, and in consequence prevents pollutants from discharging into the receiving water after small rainfall events. However, the receiving water quality improvement may not be seen as important enough to avoid acute receiving water effects in general.

  10. Relationship between race and community water and sewer service in North Carolina, USA

    PubMed Central

    MacDonald Gibson, Jacqueline

    2018-01-01

    Previous evidence has identified potential racial disparities in access to community water and sewer service in peri-urban areas adjacent to North Carolina municipalities. We performed the first quantitative, multi-county analysis of these disparities. Using publicly available data, we identified areas bordering municipalities and lacking community water and/or sewer service in 75 North Carolina counties. Logistic regression was performed to evaluate the relationship between race and access to service in peri-urban areas, controlling for population density, median home value, urban status, and percent white in the adjacent municipality. In the peri-urban areas analyzed, 67% of the population lacked community sewer service, and 33% lacked community water service. In areas other than those with no black residents, odds of having community water service (p<0.01) or at least one of the two services (p<0.05) were highest for census blocks with a small proportion of black residents and lowest in 100% black census blocks, though this trend did not hold for access to community sewer service alone. For example, odds of community water service were 85% higher in areas that were greater than 0% but less than 22% black than in 100% black areas (p<0.001). Peri-urban census blocks without black populations had the lowest odds of community water service, community sewer service, and at least one of the two services, but this difference was only statistically significant for sewer. Peri-urban areas lacking service with no black residents were wealthier than 100% black areas and areas with any percent black greater than 0%. Findings suggest two unserved groups of differing racial and socioeconomic status: (1) lower-income black populations potentially excluded from municipal services during the era of legal racial segregation and (2) higher-income non-black populations. Findings also suggest greater racial disparities in community water than community sewer services statewide. PMID:29561859

  11. Effects Of Leaky Sewers On Groundwater Quality

    NASA Astrophysics Data System (ADS)

    Leschik, S.; Musolff, A.; Reinstorf, F.; Strauch, G.; Oswald, S. E.; Schirmer, M.

    2007-12-01

    The impact of urban areas on groundwater quality has become an emerging research field in hydrogeology. Urban subsurface infrastructures like sewer networks are often leaky, so untreated wastewater may enter the urban aquifer. The transport of wastewater into the groundwater is still not well understood under field conditions. In the research platform WASSER Leipzig (Water And Sewershed Study of Environmental Risk in Leipzig- Germany) the effects of leaky sewers on the groundwater quality are investigated. The research is focused on the occurrence and transport of so-called "xenobiotics" such as pharmaceuticals and personal care product additives. Xenobiotics may pose a threat on human health, but can also be considered a marker for an urban impact on water resources. A new test site was established in Leipzig to quantify mass fluxes of xenobiotics into the groundwater from a leaky sewer. Corresponding to the leaks which were detected by closed circuit television inspections, monitoring wells were installed up- and downstream of the sewer. Concentrations of eight xenobiotics (technical-nonylphenol, bisphenol-a, caffeine, galaxolide, tonalide, carbamazepine, phenazone, ethinylestradiol) obtained from first sampling programmes were found to be highly heterogeneous, but a relation between the position of the sampling points and the sewer could not be clearly identified. However, concentrations of sodium, chloride, potassium and nitrate increased significantly downstream of the sewer which may be due to wastewater exfiltration, since no other source is known on the water flowpath from the upstream to the downstream wells. Because of the highly heterogeneous spatial distribution of xenobiotics at the test site, a monitoring concept was developed comprising both high-resolution sampling and an integral approach to obtain representative average concentrations. Direct-push techniques were used to gain insight into the fine-scale spatial distribution of the target compounds. An integral pumping test was performed to determine the total xenobiotic mass fluxes along control planes down- and upstream of the leaky sewer. The new monitoring concept helped to obtain robust estimates of xenobiotic mass fluxes into the groundwater.

  12. PROCESS DESIGN MANUAL: SURFACE DISPOSAL OF SEWAGE SLUDGE AND DOMESTIC SEPTAGE

    EPA Science Inventory

    Human domestic activities generate wastewater that is piped into municipal sewer systems, underground septic tanks, or portable sanitation devices. Wastewater in municipal systems is treated before being discharged into the environment, as required under the Clean Water Act. This...

  13. Environmental Assessment for the Construction and Operation of a Battalion Headquarters for the U.S. Army Priority Air Transport at Joint Base Andrews-Naval Air Facility Washington, Prince George’s County, Maryland

    DTIC Science & Technology

    2012-12-01

    counts for gate accessible off-base roadways..........................3-10 Table 3-9 Labor force and unemployment ...association with steep stream banks . JBA sits on a plateau between the Anacostia River and the Patuxent River. Surface elevations at JBA range from...storm sewer lines cause isolated ponding during low-intensity rainfalls (URS 2012). The base operates under two general NPDES permits: (1) Multi- Sector

  14. pH Meter probe assembly

    DOEpatents

    Hale, C.J.

    1983-11-15

    An assembly for mounting a pH probe in a flowing solution, such as a sanitary sewer line, which prevents the sensitive glass portion of the probe from becoming coated with grease, oil, and other contaminants, whereby the probe gives reliable pH indication over an extended period of time. The pH probe assembly utilizes a special filter media and a timed back-rinse feature for flushing clear surface contaminants of the filter. The flushing liquid is of a known pH and is utilized to check performance of the probe. 1 fig.

  15. pH Meter probe assembly

    DOEpatents

    Hale, Charles J.

    1983-01-01

    An assembly for mounting a pH probe in a flowing solution, such as a sanitary sewer line, which prevents the sensitive glass portion of the probe from becoming coated with grease, oil, and other contaminants, whereby the probe gives reliable pH indication over an extended period of time. The pH probe assembly utilizes a special filter media and a timed back-rinse feature for flushing clear surface contaminants of the filter. The flushing liquid is of a known pH and is utilized to check performance of the probe.

  16. Developments in a methodology for the design of engineered invert traps in combined sewer systems.

    PubMed

    Buxton, A; Tait, S; Stovin, V; Saul, A

    2002-01-01

    Sediments within sewers can have a significant effect on the operation of the sewer system and on the surrounding natural and urban environment. One possible method for the management of sewer sediments is the use of slotted invert traps. Although invert traps can be used to selectively trap only inorganic bedload material, little is known with regard to the design of these structures. This paper presents results from a laboratory investigation comparing the trapping performance of three slot size configurations of a laboratory-scale invert trap. The paper also presents comparative results from a two-dimensional computational model utilising stochastic particle tracking. This investigation shows that particle tracking consistently over-predicts sediment retention efficiencies observed within the laboratory model.

  17. Effects of combined-sewer overflows and urban runoff on the water quality of Fall Creek, Indianapolis, Indiana

    USGS Publications Warehouse

    Martin, Jeffrey D.

    1995-01-01

    Concentrations of dissolved oxygen measured at the station in the middle of the combined-sewer overflows were less than the Indiana minimum ambient water-quality standard of 4.0 milligrams per liter during all storms. Concentrations of ammonia, oxygen demand, copper, lead, zinc, and fecal coliform bacteria at the stations downstream from the combined-sewer overflows were much higher in storm runoff than in base flow. Increased concentrations of oxygen demand in runoff probably were caused by combined-sewer overflows, urban runoff, and the resuspension of organic material deposited on the streambed. Some of the increased concentrations of lead, zinc, and probably copper can be attributed to the discharge and resuspension of filter backwash

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION OF URBAN RUNOFF MODELS

    EPA Science Inventory

    This paper will present the verification process and available results of the XP-SWMM modeling system produced by XP-Software conducted unde the USEPA's ETV Program. Wet weather flow (WWF) models are used throughout the US for the evaluation of storm and combined sewer systems. M...

  19. Municipal gravity sewers: an unrecognised source of nitrous oxide

    EPA Science Inventory

    Nitrous oxide (N2O) is a primary ozone-depleting substance and powerful greenhouse gas. N2O emissions from secondary-level wastewater treatment processes are relatively well understood as a result of intensive international research effort in recent times, yet little information...

  20. Hydrocarbons and heavy metals in the different sewer deposits in the 'Le Marais' catchment (Paris, France): stocks, distributions and origins.

    PubMed

    Rocher, Vincent; Azimi, Sam; Moilleron, Régis; Chebbo, Ghassan

    2004-05-05

    The knowledge of the pollution stored in combined sewers is of prime importance in terms of management of wet weather flow pollution since sewer deposits play a significant role as source of pollution in combined sewer overflows. This work, which focused on the hydrocarbon (aliphatic and aromatic hydrocarbons) and metallic (Fe, Zn, Pb, Cu and Cd) pollution fixed to the different kinds of sewer deposits (gross bed sediment [GBS], organic layer [OL] and biofilm), was performed in order to provide a complete overview of the contaminant storage in the 'Le Marais' combined sewer (Central Paris, France). Firstly, our results have shown that, for all kinds of pollutants, a major part was stored in the GBS (87 to 98%), a lesser part in the OL (2 to 13%) and an insignificant part in the biofilm (<1%). These results demonstrated that the potential contribution of biofilm to wet weather pollution was negligible compared to the OL one. Secondly, the investigation of hydrocarbon fingerprints in each deposit has provided relevant information about contamination origins: (1) aliphatic hydrocarbon distributions were indicative of petroleum input in the GBS and reflected a mixture of biogenic and petroleum inputs in the OL and biofilm, (2) aromatic hydrocarbon distributions suggested an important pyrolytic contamination in all the deposits. Finally, the study of pollutant fingerprints in the different deposits and in the suspended solids going through the collector has shown that: (1) the suspended solids were the major component of OL and biofilm while urban runoff seemed to be the main transport mechanism introducing pollutants in the GBS and (2) the residence times in sewer of OL and biofilm were quite short compared to those for GBS.

  1. Web Based Decision Support Tools for Selection of Condition ...

    EPA Pesticide Factsheets

    Abstract: It has been observed that the majority of older sewer laterals made of concrete or terracotta pipe are deteriorating rapidly. Wastewater agencies, typically responsible for maintaining the portion of the sewer lateral located in the public right-of-way, and property owners, typically responsible for the portion of the lateral located within the private property,face the dilemma of whether to replace or rehabilitate deteriorated laterals at significant expense. Deferment of needed rehabilitation translates to increase in the wastewater agency annual operation and maintenance budget and increased risk to the property owner. Sewer lateral deterioration leads to pipe collapse and costly sewer backup. Increase in transmission and treatment costs due to inflow and infiltration (I/I) into the public sewer system is inevitably borne by the ratepayer. [NOTE: The link below connects to a WERF site where the Final Report can be downloaded for free, after registering at the WERF site. For some projects the Executive Summary is available and can be downloaded for free without registering on the WERF site.] A new web portal has been developed that provides wastewater agencies and property owners with up to date information on sewer lateral inspection techniques, repair and rehabilitation methods, as well as relevant legal and financial issues. The site also offers a discussion forum for sharing knowledge and experiences on this topic. The portal is hosted on

  2. The distribution dynamics and desorption behaviour of mobile pharmaceuticals and caffeine to combined sewer sediments.

    PubMed

    Hajj-Mohamad, M; Darwano, H; Duy, S Vo; Sauvé, S; Prévost, M; Arp, H P H; Dorner, S

    2017-01-01

    Pharmaceuticals are discharged to the environment from wastewater resource recovery facilities, sewer overflows, and illicit sewer connections. To understand the fate of pharmaceuticals, there is a need to better understand their sorption dynamics to suspended sediments (SS) and settled sediments (StS) in sewer systems. In this study, such sorption dynamics to both SS and StS were assessed using a batch equilibrium method under both static and dynamic conditions. Experiments were performed with natively occurring and artificially modified concentrations of sewer pharmaceuticals (acetaminophen, theophylline, carbamazepine, and a metabolite of carbamazepine) and caffeine. Differences in apparent distribution coefficients, K d,app , between SS and StS were related to differences in their organic carbon (OC) content, and the practice of artificially modifying the concentration. K d,app values of modified contaminant concentrations and high OC sediments were substantially higher. Pseudo-second order desorption rates for these mobile compounds were also quantified. Successive flushing events to simulate the addition of stormwater to sewer networks revealed that aqueous concentrations would not necessarily decrease, because the added water will rapidly return to equilibrium concentrations with the sediments. Sorption and desorption kinetics must be considered in addition to dilution, to avoid underestimating the influence of dilution on concentrations of pharmaceuticals discharged to the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Variability estimation of urban wastewater biodegradable fractions by respirometry.

    PubMed

    Lagarde, Fabienne; Tusseau-Vuillemin, Marie-Hélène; Lessard, Paul; Héduit, Alain; Dutrop, François; Mouchel, Jean-Marie

    2005-11-01

    This paper presents a methodology for assessing the variability of biodegradable chemical oxygen demand (COD) fractions in urban wastewaters. Thirteen raw wastewater samples from combined and separate sewers feeding the same plant were characterised, and two optimisation procedures were applied in order to evaluate the variability in biodegradable fractions and related kinetic parameters. Through an overall optimisation on all the samples, a unique kinetic parameter set was obtained with a three-substrate model including an adsorption stage. This method required powerful numerical treatment, but improved the identifiability problem compared to the usual sample-to-sample optimisation. The results showed that the fractionation of samples collected in the combined sewer was much more variable (standard deviation of 70% of the mean values) than the fractionation of the separate sewer samples, and the slowly biodegradable COD fraction was the most significant fraction (45% of the total COD on average). Because these samples were collected under various rain conditions, the standard deviations obtained here on the combined sewer biodegradable fractions could be used as a first estimation of the variability of this type of sewer system.

  4. Coupled 1-D sewer and street networks and 2-D flooding model to rapidly evaluate surface inundation

    NASA Astrophysics Data System (ADS)

    Kao, Hong-Ming; Hsu, Hao-Ming

    2017-04-01

    Flash floods have occurred frequently in the urban areas around the world and cause the infrastructure and people living to expose continuously in the high risk level of pluvial flooding. According to historical surveys, the major reasons of severe surface inundations in the urban areas can be attributed to heavy rainfall in the short time and/or drainage system failure. In order to obtain real-time flood forecasting with high accuracy and less uncertainty, an appropriate system for predicting floods is necessary. For the reason, this study coupled 1-D sewer and street networks and 2-D flooding model as an operational modelling system for rapidly evaluating surface inundation. The proposed system is constructed by three significant components: (1) all the rainfall-runoff of a sub-catchment collected via gullies is simulated by the RUNOFF module of the Storm Water Management Model (SWMM); (2) and directly drained to the 1-D sewer and street networks via manholes as inflow discharges to conduct flow routing by using the EXTRAN module of SWMM; (3) after the 1-D simulations, the surcharges from manholes are considered as point sources in 2-D overland flow simulations that are executed by the WASH123D model. It can thus be used for urban flood modelling that reflects the rainfall-runoff processes, and the dynamic flow interactions between the storm sewer system and the ground surface in urban areas. In the present study, we adopted the Huwei Science and Technology Park, located in the south-western part of Taiwan, as the demonstration area because of its high industrial values. The region has an area about 1 km2 with approximately 1 km in both length and width. It is as isolated urban drainage area in which there is a complete sewer system that collects the runoff and drains to the detention pond. Based on the simulated results, the proposed modelling system was found that the simulated floods fit to the survey records because the physical rainfall-runoff phenomena in urban environment were better reflected. Keywords: SWMM, WASH123D, surface inundation, real-time.

  5. Consequential environmental and economic life cycle assessment of green and gray stormwater infrastructures for combined sewer systems.

    PubMed

    Wang, Ranran; Eckelman, Matthew J; Zimmerman, Julie B

    2013-10-01

    A consequential life cycle assessment (LCA) is conducted to evaluate the trade-offs between water quality improvements and the incremental climate, resource, and economic costs of implementing green (bioretention basin, green roof, and permeable pavement) versus gray (municipal separate stormwater sewer systems, MS4) alternatives of stormwater infrastructure expansions against a baseline combined sewer system with combined sewer overflows in a typical Northeast US watershed for typical, dry, and wet years. Results show that bioretention basins can achieve water quality improvement goals (e.g., mitigating freshwater eutrophication) for the least climate and economic costs of 61 kg CO2 eq. and $98 per kg P eq. reduction, respectively. MS4 demonstrates the minimum life cycle fossil energy use of 42 kg oil eq. per kg P eq. reduction. When integrated with the expansion in stormwater infrastructure, implementation of advanced wastewater treatment processes can further reduce the impact of stormwater runoff on aquatic environment at a minimal environmental cost (77 kg CO2 eq. per kg P eq. reduction), which provides support and valuable insights for the further development of integrated management of stormwater and wastewater. The consideration of critical model parameters (i.e., precipitation intensity, land imperviousness, and infrastructure life expectancy) highlighted the importance and implications of varying local conditions and infrastructure characteristics on the costs and benefits of stormwater management. Of particular note is that the impact of MS4 on the local aquatic environment is highly dependent on local runoff quality indicating that a combined system of green infrastructure prior to MS4 potentially provides a more cost-effective improvement to local water quality.

  6. Blood, sweat, tears and success of technology transfer long-term controlled-release of herbicides: Root-growth-inhibiting biobarrier technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Voris, P.; Cataldo, D.A.; Burton, F.G.

    Through the unique combination of polymers with a herbicidally active dinitroaniline, a cylinderical pellet (9mm long and 9mm in diameter) was developed that continuously releases a herbicide for a period of up to 100 years. Equilibrium concentration of the herbicide in soil adjacent to the pellet and the bioactive lifetime of the device cam be adjusted by changing the size of the pellet; the type of polymer; the type, quality, and quantity of carrier; and/or the concentration and type of dinitroaniline used. Commercial products that have been developed under a Federal Technology Transfer Program that utilize this technology include: (1)more » ROOT-SHIELD, a root repelling sewer gasket for concrete, clay, and PVC sewer lines, (2) BIOBARRIER, a spun-bonded polypropylene geotextile fabric developed to prevent root growth from invading septic tanks; penetrating under roadways, and along the edge of sidewalks, airport runways, and tennis courts, and for landscaped areas; and (3) ROOT-GUARD, a plastic drip irrigation emitter designed to protect buried drip irrigation systems from being plugged by roots. 17 refs., 4 figs., 6 tabs.« less

  7. Process Design Manual: Wastewater Treatment Facilities for Sewered Small Communities.

    ERIC Educational Resources Information Center

    Leffel, R. E.; And Others

    This manual attempts to describe new treatment methods, and discuss the application of new techniques for more effectively removing a broad spectrum of contaminants from wastewater. Topics covered include: fundamental design considerations, flow equalization, headworks components, clarification of raw wastewater, activated sludge, package plants,…

  8. Simulation of floods caused by overloaded sewer systems: extensions of shallow-water equations

    NASA Astrophysics Data System (ADS)

    Hilden, Michael

    2005-03-01

    The outflow of water from a manhole onto a street is a typical flow problem within the simulation of floods in urban areas that are caused by overloaded sewer systems in the event of heavy rains. The reliable assessment of the flood risk for the connected houses requires accurate simulations of the water flow processes in the sewer system and in the street.The Navier-Stokes equations (NSEs) describe the free surface flow of the fluid water accurately, but since their numerical solution requires high CPU times and much memory, their application is not practical. However, their solutions for selected flow problems are applied as reference states to assess the results of other model approaches.The classical shallow-water equations (SWEs) require only fractions (factor 1/100) of the NSEs' computational effort. They assume hydrostatic pressure distribution, depth-averaged horizontal velocities and neglect vertical velocities. These shallow-water assumptions are not fulfilled for the outflow of water from a manhole onto the street. Accordingly, calculations show differences between NSEs and SWEs solutions.The SWEs are extended in order to assess the flood risks in urban areas reliably within applicable computational efforts. Separating vortex regions from the main flow and approximating vertical velocities to involve their contributions into a pressure correction yield suitable results.

  9. 2. ENVIRONMENT, FROM EAST, SHOWING BOSTON STREET BRIDGE CARRYING BOSTON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. ENVIRONMENT, FROM EAST, SHOWING BOSTON STREET BRIDGE CARRYING BOSTON STREET OVER HARRIS CREEK SEWER - Boston Street Bridge, Spanning Harris Creek Sewer at Boston Street, Baltimore, Independent City, MD

  10. Status of Civil Judicial Consent Decrees Addressing Combined Sewer Systems (CSOs)

    EPA Pesticide Factsheets

    Tracking table of civil consent decrees for combined sewer systems (CSOs). This supports the National Enforcement Initiative (NEI) for Keeping Raw Sewage and Contaminated Stormwater Out of Our Nation's Waters.

  11. Moving towards Total Water Management

    EPA Science Inventory

    The presentation will discuss the following topics: Stormwater Best Management Practice (BMP) Placement (SUSTAIN); Sanitary Sewer Overflow Toolbox (SSOAP); BMP and Low Impact Development (LID) Performance; Green/Grey Infrastructure for Stormwater; Combined Sewers and Reuse; Infra...

  12. Effect of flow rate on growth and oxygen consumption of biofilm in gravity sewer.

    PubMed

    Xu, Jingwei; Li, Muzhi; He, Qiang; Sun, Xingfu; Zhou, Xiangren; Su, Zhenping; Ai, Hainan

    2017-01-01

    The function of sewer as reactors must rely on the biofilm in it. In this paper, the formation, structure, oxygen transfer, and activity of the biofilm under different hydraulic conditions were studied by the microelectrode technology, oxygen uptake rate (OUR) technology, and 454 high-throughput pyrosequencing technology. Results showed that when the wall-shear stresses were 1.12, 1.29, and 1.45 Pa, the porosity of the steady-state biofilm were 69.1, 64.4, and 55.1 %, respectively. The maximum values of OUR were 0.033, 0.027, and 0.022 mg/(L*s), respectively, and the COD removal efficiency in the sewers reached 40, 35, and 32 %, respectively. The research findings had an important significance on how to improve the treatment efficiency of the sewers. Fig. a Graphical Abstract.

  13. A risk-based approach to sanitary sewer pipe asset management.

    PubMed

    Baah, Kelly; Dubey, Brajesh; Harvey, Richard; McBean, Edward

    2015-02-01

    Wastewater collection systems are an important component of proper management of wastewater to prevent environmental and human health implications from mismanagement of anthropogenic waste. Due to aging and inadequate asset management practices, the wastewater collection assets of many cities around the globe are in a state of rapid decline and in need of urgent attention. Risk management is a tool which can help prioritize resources to better manage and rehabilitate wastewater collection systems. In this study, a risk matrix and a weighted sum multi-criteria decision-matrix are used to assess the consequence and risk of sewer pipe failure for a mid-sized city, using ArcGIS. The methodology shows that six percent of the uninspected sewer pipe assets of the case study have a high consequence of failure while four percent of the assets have a high risk of failure and hence provide priorities for inspection. A map incorporating risk of sewer pipe failure and consequence is developed to facilitate future planning, rehabilitation and maintenance programs. The consequence of failure assessment also includes a novel failure impact factor which captures the effect of structurally defective stormwater pipes on the failure assessment. The methodology recommended in this study can serve as a basis for future planning and decision making and has the potential to be universally applied by municipal sewer pipe asset managers globally to effectively manage the sanitary sewer pipe infrastructure within their jurisdiction. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Long-term impacts on sewers following food waste disposer installation in housing areas.

    PubMed

    Mattsson, Jonathan; Hedström, Annelie; Viklander, Maria

    2014-01-01

    To increase biogas generation and decrease vehicle transportation of solid waste, the integration of food waste disposers (FWDs) into the wastewater system has been proposed. However, concerns have been raised about the long-term impact of the additional load of the FWDs on sewer systems. To examine the said impact, this study has used closed-circuit television inspection techniques to evaluate the status of 181 concrete pipes serving single family housing areas with a diameter of 225 mm, ranging from a 100% connection rate of households with an FWD to none. A minor study was also performed on a multi-family housing area, where mainly plastic pipes (200 mm) were used. The extent and distribution of deposits related to the ratio of FWDs, inclination and pipe sagging (backfalls) were ascertained by using linear regression and analysis of variance. The results showed that FWDs have had an impact on the level of deposits in the sewer, but this has, in turn, been of minor significance. With a high connection rate of FWDs upstream of a pipe, the extent of the total level of deposits, as well as finer sediments, was statistically determined to be greater. However, the majority of the deposits were observed to be small, which would suggest the impact of FWDs on sewer performance to be minor. As food waste not compatible with the FWD was seen in the sewers, educational campaigns could be beneficial to further lower the risks of sewer blocking.

  15. Identification of in-sewer sources of organic solids contributing to combined sewer overflows.

    PubMed

    Ahyerre, M; Chebbo, G

    2002-09-01

    Previous research has shown that combined sewer systems are the main source of particle and organic pollution during rainfall events contributing to combined sewer overflow. The aim of this article is to identify in an urban catchment area called "Le Marais", in the center of Paris, the types of sediments that are eroded and contribute to the pollution of combined sewer overflow. Three sediment types are considered: granular material found in the inverts of pipes, organic biofilms and organic sediment at the water bed interface, identified as an immobile layer in the "Le Marais" catchment area. The method used consist, firstly, of sampling and assessing the organic pollutant loads and metallic loads of the particles in each type of sediment. Then, the mass of each type of sediment is assessed. The mass and the characteristics of each type of sediment is finally compared to the mass and characteristics of the particles eroded in the catchment area, estimated by mass balances, in order to find the source of eroded particles. The only identified type of deposit that can contribute to combined sewer overflows is the organic layer. Indeed, the solids of this layer have mean and metallic loads that are of the same order of magnitude as the eroded particles. Moreover, the mass of the organic layer considered over different time scales is of the same order of magnitude as the eroded masses during rainfall events and an erosion experiment showed that the organic layer is actually eroded.

  16. 7 CFR 1980.451 - Filing and processing applications.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... (k) Certificate of need. If the loan request is for health care facilities (e.g., hospitals or... schools, water, sewer and health care services, and if so, the community's plan for providing such... Certificate of Need (Health Care Facilities) 3 Clean Air and Water Pollution Control Act Requirements...

  17. 7 CFR 1980.451 - Filing and processing applications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of the subpart. (k) Certificate of need. If the loan request is for health care facilities (e.g... schools, water, sewer and health care services, and if so, the community's plan for providing such... Certificate of Need (Health Care Facilities) 3 Clean Air and Water Pollution Control Act Requirements...

  18. 7 CFR 1980.451 - Filing and processing applications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of the subpart. (k) Certificate of need. If the loan request is for health care facilities (e.g... schools, water, sewer and health care services, and if so, the community's plan for providing such... Certificate of Need (Health Care Facilities) 3 Clean Air and Water Pollution Control Act Requirements...

  19. 7 CFR 1980.451 - Filing and processing applications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of the subpart. (k) Certificate of need. If the loan request is for health care facilities (e.g... schools, water, sewer and health care services, and if so, the community's plan for providing such... Certificate of Need (Health Care Facilities) 3 Clean Air and Water Pollution Control Act Requirements...

  20. Student Research in the Year of the Coast.

    ERIC Educational Resources Information Center

    Kane, Julian; And Others

    1980-01-01

    Described is independent study research at Garden City High School (Garden City, NY) involving ten students studying seasonal beach erosion, salt marsh preservation, sludge leachate hazards in bays, and sewer outfall effects on barrier bays. Outcomes include better understanding of the scientific process and careful, accurate research. (Author/DS)

  1. Physical disintegration of toilet papers in wastewater systems: experimental analysis and mathematical modeling.

    PubMed

    Eren, Beytullah; Karadagli, Fatih

    2012-03-06

    Physical disintegration of representative toilet papers was investigated in this study to assess their disintegration potential in sewer systems. Characterization of toilet papers from different parts of the world indicated two main categories as premium and average quality. Physical disintegration experiments were conducted with representative products from each category according to standard protocols with improvements. The experimental results were simulated by mathematical model to estimate best-fit values of disintegration rate coefficients and fractional distribution ratios. Our results from mathematical modeling and experimental work show that premium products release more amounts of small fibers and disintegrate more slowly than average ones. Comparison of the toilet papers with the tampon applicators studied previously indicates that premium quality toilet papers present significant potential to persist in sewer pipes. Comparison of turbulence level in our experimental setup with those of partial flow conditions in sewer pipes indicates that drains and small sewer pipes are critical sections where disintegration of toilet papers will be limited. For improvement, requirements for minimum pipe slopes may be increased to sustain transport and disintegration of flushable products in small pipes. In parallel, toilet papers can be improved to disintegrate rapidly in sewer systems, while they meet consumer expectations.

  2. Spatial variability of characteristics and origins of urban wet weather pollution in combined sewers.

    PubMed

    Kafi-Benyahia, M; Gromaire, M G; Chebbo, G

    2005-01-01

    An experimental on-site observatory of urban pollutant loads in combined sewers was created in the centre of Paris to quantify and characterise the dry and wet weather flow in relation to spatial scale. Eight rainfall events were studied from April 2003 to May 2004. Samples were analysed for suspended solids, organic matter, nitrogen and heavy metals. Results confirm the extent of wet weather pollution. They have shown the relative homogeneity of SS and organic matter characteristics from one urban catchment area to another. Two groups of heavy metals were identified. The first one concerns Cu, which has a higher concentration in wet weather flow (WWF) than in dry weather flow (DWF), and runoff. The second includes Cd, Pb and Zn, where higher concentrations were measured in urban runoff than in WWF and DWF. A first evaluation of contribution of wastewater, urban runoff and sewer deposit erosion sources to wet weather pollution was established and has highlighted the contribution of wastewater and sewer deposits to this pollution. However, it has shown that sewer deposit erosion remains an important source of wet weather pollution at different spatial scales.

  3. Research of trace metals as markers of entry pathways in combined sewers.

    PubMed

    Gounou, C; Varrault, G; Amedzro, K; Gasperi, J; Moilleron, R; Garnaud, S; Chebbo, G

    2011-01-01

    Combined sewers receive high toxic trace metal loads emitted by various sources, such as traffic, industry, urban heating and building materials. During heavy rain events, Combined Sewer Overflows (CSO) can occur and, if so, are discharged directly into the aquatic system and therefore could have an acute impact on receiving waters. In this study, the concentrations of 18 metals have been measured in 89 samples drawn from the three pollutant Entry Pathways in Combined Sewers (EPCS): i) roof runoff, ii) street runoff, and iii) industrial and domestic effluents and also drawn from sewer deposits (SD). The aim of this research is to identify metallic markers for each EPCS; the data matrix was submitted to principal component analysis in order to determine metallic markers for the three EPCS and SD. This study highlights the fact that metallic content variability across samples from different EPCS and SD exceeds the spatio-temporal variability of samples from the same EPCS. In the catchment studied here, the most valuable EPCS and SD markers are lead, sodium, boron, antimony and zinc; these markers could be used in future studies to identify the contributions of each EPCS to CSO metallic loads.

  4. Design and performance evaluation of a simplified dynamic model for combined sewer overflows in pumped sewer systems

    NASA Astrophysics Data System (ADS)

    van Daal-Rombouts, Petra; Sun, Siao; Langeveld, Jeroen; Bertrand-Krajewski, Jean-Luc; Clemens, François

    2016-07-01

    Optimisation or real time control (RTC) studies in wastewater systems increasingly require rapid simulations of sewer systems in extensive catchments. To reduce the simulation time calibrated simplified models are applied, with the performance generally based on the goodness of fit of the calibration. In this research the performance of three simplified and a full hydrodynamic (FH) model for two catchments are compared based on the correct determination of CSO event occurrences and of the total discharged volumes to the surface water. Simplified model M1 consists of a rainfall runoff outflow (RRO) model only. M2 combines the RRO model with a static reservoir model for the sewer behaviour. M3 comprises the RRO model and a dynamic reservoir model. The dynamic reservoir characteristics were derived from FH model simulations. It was found that M2 and M3 are able to describe the sewer behaviour of the catchments, contrary to M1. The preferred model structure depends on the quality of the information (geometrical database and monitoring data) available for the design and calibration of the model. Finally, calibrated simplified models are shown to be preferable to uncalibrated FH models when performing optimisation or RTC studies.

  5. Bayesian analysis for erosion modelling of sediments in combined sewer systems.

    PubMed

    Kanso, A; Chebbo, G; Tassin, B

    2005-01-01

    Previous research has confirmed that the sediments at the bed of combined sewer systems are the main source of particulate and organic pollution during rain events contributing to combined sewer overflows. However, existing urban stormwater models utilize inappropriate sediment transport formulas initially developed from alluvial hydrodynamics. Recently, a model has been formulated and profoundly assessed based on laboratory experiments to simulate the erosion of sediments in sewer pipes taking into account the increase in strength with depth in the weak layer of deposits. In order to objectively evaluate this model, this paper presents a Bayesian analysis of the model using field data collected in sewer pipes in Paris under known hydraulic conditions. The test has been performed using a MCMC sampling method for calibration and uncertainty assessment. Results demonstrate the capacity of the model to reproduce erosion as a direct response to the increase in bed shear stress. This is due to the model description of the erosional strength in the deposits and to the shape of the measured bed shear stress. However, large uncertainties in some of the model parameters suggest that the model could be over-parameterised and necessitates a large amount of informative data for its calibration.

  6. Advanced Concepts Research Initiative

    EPA Science Inventory

    This initiative is investigating various approaches to controlling and treating wet-weather flow (WWF) discharges in the urban watershed. WWF, including combined sewer overflow (CSO), sanitary sewer overflow (SSO) and stormwater discharges are leading causes of receiving water q...

  7. Pressurized storm sewer simulation : model enhancement.

    DOT National Transportation Integrated Search

    1991-01-01

    A modified Pressurized Flow Simulation Model, PFSM, was developed and attached to the Federal Highway Administration, FHWA, Pool Funded PFP-HYDRA Package. Four hydrograph options are available for simulating inflow to a sewer system under surcharge o...

  8. A Screening Assessment of the Potential Impacts of Climate ...

    EPA Pesticide Factsheets

    EPA announced the availability of the report, A Screening Assessment of the Potential Impacts of Climate Change on Combined Sewer Overflow (CSO) Mitigation in the Great Lakes and New England Regions. This report is a screening-level assessment of the potential implications climate change has had on combined sewer overflow (CSO) mitigation in the Great Lakes and New England Regions. This report describes the potential scope and magnitude of climate change impacts on combined sewer overflow (CSOs) mitigation efforts in the Great Lakes Region and New England Region.

  9. Feasibility of sulfide control in sewers by reuse of iron rich drinking water treatment sludge.

    PubMed

    Sun, Jing; Pikaar, Ilje; Sharma, Keshab Raj; Keller, Jürg; Yuan, Zhiguo

    2015-03-15

    Dosage of iron salt is the most commonly used method for sulfide control in sewer networks but incurs high chemical costs. In this study, we experimentally investigate the feasibility of using iron rich drinking water treatment sludge for sulfide control in sewers. A lab-scale rising main sewer biofilm reactor was used. The sulfide concentration in the effluent decreased from 15.5 to 19.8 mgS/L (without dosing) to below 0.7-2.3 mgS/L at a sludge dosing rate achieving an iron to total dissolved inorganic sulfur molar ratio (Fe:S) of 1:1, with further removal of sulfide possible by prolonging the reaction time. In fact, batch tests revealed an Fe consumption to sulfide removal ratio of 0.5 ± 0.02 (mole:mole), suggesting the possible occurrence of other reactions involving the removal of sulfide. Modelling revealed that the reaction between iron in sludge and sulfide has reaction orders of 0.65 ± 0.01 and 0.77 ± 0.02 with respect to the Fe and sulfide concentrations, respectively. The addition of sludge slightly increased the total chemical oxidation demand (tCOD) concentration (by approximately 12%) as expected, but decreased the soluble chemical oxidation demand (sCOD) concentration and methane formation by 7% and 20%, respectively. Some phosphate removal (13%) was also observed at the sludge dosing rate of 1:1 (Fe:S), which is beneficial to nutrient removal from the wastewater. Overall, this study suggests that dosing iron-rich drinking water sludge to sewers could be an effective strategy for sulfide removal in sewer systems, which would also reduce the sludge disposal costs for drinking water treatment works. However, its potential side-effects on sewer sedimentation and on the wastewater treatment plant effluent remain to be investigated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. A Microbial Signature Approach to Identify Fecal Pollution in the Waters Off an Urbanized Coast of Lake Michigan

    PubMed Central

    Newton, Ryan J.; Bootsma, Melinda J.; Morrison, Hilary G.; Sogin, Mitchell L.

    2014-01-01

    Urban coasts receive watershed drainage from ecosystems that include highly developed lands with sewer and stormwater infrastructure. In these complex ecosystems, coastal waters are often contaminated with fecal pollution, where multiple delivery mechanisms that often contain multiple fecal sources make it difficult to mitigate the pollution. Here, we exploit bacterial community sequencing of the V6 and V6V4 hypervariable regions of the bacterial 16S rRNA gene to identify bacterial distributions that signal the presence of sewer, fecal, and human fecal pollution. The sequences classified to three sewer infrastructure-associated bacterial genera, Acinetobacter, Arcobacter, and Trichococcus, and five fecal-associated bacterial families, Bacteroidaceae, Porphyromonadaceae, Clostridiaceae, Lachnospiraceae, and Ruminococcaceae, served as signatures of sewer and fecal contamination, respectively. The human fecal signature was determined with the Bayesian source estimation program SourceTracker, which we applied to a set of 40 sewage influent samples collected in Milwaukee, WI, USA to identify operational taxonomic units (≥97 % identity) that were most likely of human fecal origin. During periods of dry weather, the magnitudes of all three signatures were relatively low in Milwaukee's urban rivers and harbor and nearly zero in Lake Michigan. However, the relative contribution of the sewer and fecal signature frequently increased to >2 % of the measured surface water communities following sewer overflows. Also during combined sewer overflows, the ratio of the human fecal pollution signature to the fecal pollution signature in surface waters was generally close to that of sewage, but this ratio decreased dramatically during dry weather and rain events, suggesting that nonhuman fecal pollution was the dominant source during these weather-driven scenarios. The qPCR detection of two human fecal indicators, human Bacteroides and Lachno2, confirmed the urban fecal footprint in this ecosystem extends to at least 8 km offshore. PMID:23475306

  11. Modelling the influence of total suspended solids on E. coli removal in river water.

    PubMed

    Qian, Jueying; Walters, Evelyn; Rutschmann, Peter; Wagner, Michael; Horn, Harald

    2016-01-01

    Following sewer overflows, fecal indicator bacteria enter surface waters and may experience different lysis or growth processes. A 1D mathematical model was developed to predict total suspended solids (TSS) and Escherichia coli concentrations based on field measurements in a large-scale flume system simulating a combined sewer overflow. The removal mechanisms of natural inactivation, UV inactivation, and sedimentation were modelled. For the sedimentation process, one, two or three particle size classes were incorporated separately into the model. Moreover, the UV sensitivity coefficient α and natural inactivation coefficient kd were both formulated as functions of TSS concentration. It was observed that the E. coli removal was predicted more accurately by incorporating two particle size classes. However, addition of a third particle size class only improved the model slightly. When α and kd were allowed to vary with the TSS concentration, the model was able to predict E. coli fate and transport at different TSS concentrations accurately and flexibly. A sensitivity analysis revealed that the mechanisms of UV and natural inactivation were more influential at low TSS concentrations, whereas the sedimentation process became more important at elevated TSS concentrations.

  12. SEWER PIPELINE PERFORMANCE INDICATORS

    EPA Science Inventory

    Wastewater collection systems are an extensive part of the nation's infrastructure. In the United States, approximately 150 million people are served by about 19,000 municipal wastewater collection systems representing about 500,000 miles of sewer pipe (not including privately o...

  13. 40 CFR 35.2005 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sludge; aquifer recharge; aquaculture; direct reuse (non-potable); horticulture; revegetation of... design-type projects within the scope of the practice of architecture or professional engineering as... as designed. (10) Collector sewer. The common lateral sewers, within a publicly owned treatment...

  14. 40 CFR 35.2005 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sludge; aquifer recharge; aquaculture; direct reuse (non-potable); horticulture; revegetation of... design-type projects within the scope of the practice of architecture or professional engineering as... as designed. (10) Collector sewer. The common lateral sewers, within a publicly owned treatment...

  15. 40 CFR 35.2005 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sludge; aquifer recharge; aquaculture; direct reuse (non-potable); horticulture; revegetation of... design-type projects within the scope of the practice of architecture or professional engineering as... as designed. (10) Collector sewer. The common lateral sewers, within a publicly owned treatment...

  16. 40 CFR 35.2005 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... economic investigations or studies, surveys, designs, plans, working drawings, specifications, procedures... design-type projects within the scope of the practice of architecture or professional engineering as... as designed. (10) Collector sewer. The common lateral sewers, within a publicly owned treatment...

  17. 40 CFR 35.2005 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... economic investigations or studies, surveys, designs, plans, working drawings, specifications, procedures... design-type projects within the scope of the practice of architecture or professional engineering as... as designed. (10) Collector sewer. The common lateral sewers, within a publicly owned treatment...

  18. USEPA CAPSTONE REPORT: DISINFECTION

    EPA Science Inventory

    Wet-weather flow (WWF), including combined-sewer overflow (CSO), sanitary-sewer overflow, and stormwater (SW) is a significant contributor of microbial contamination to surface water and ground water. Contamination with human-origin fecal coliform (FC) is of great concern for san...

  19. VERIFICATION OF HIGH-RATE DISINFECTION TECHNOLOGIES FOR WET-WEATHER FLOWS

    EPA Science Inventory

    This paper describes the critical components of the USEPA's Environmental Technology Verification Program for two specific technologies categories: ultraviolet disinfection technologies for treating combined sewer overflow (CSO) and sanitary sewer overflow (SSO), and; induction m...

  20. EXFILTRATION IN SEWER SYSTEMS

    EPA Science Inventory

    This study focused on the quantification of leakage of sanitary and industrial sewage from sanitary sewer pipes on a national basis. The method for estimating exfiltration amounts utilized groundwater talbe information to identify areas of the country where the hydraulic gradient...

  1. OPTIMIZATION OF COMBINED SEWER OVERFLOW CONTROL SYSTEMS

    EPA Science Inventory

    The highly variable and intermittent pollutant concentrations and flowrates associated with wet-weather events in combined sewersheds necessitates the use of storage-treatment systems to control pollution.An optimized combined-sewer-overflow (CSO) control system requires a manage...

  2. ESTIMATING URBAN WET-WEATHER POLLUTANT LOADING

    EPA Science Inventory

    This paper presents procedures for estimating pollutant loads in urban watersheds emanating from wet-weather flow discharge. Equations for pollutant loading estimates will focus on the effects of wastewater characteristics, sewer flow carrying velocity, and sewer-solids depositi...

  3. MANAGEMENT OF COMBINED SEWER OVERFLOW: RESEARCH PROGRAM CAPSTONE

    EPA Science Inventory

    Combined-sewer overflow (CSO) is a mixture of urban storm drainage, municipal-industrial wastewater, and subterranean infiltration. Untreated discharges of CSOs have caused substantial pollution impacts on the quality of receiving-water bodies. Problem constituents include visi...

  4. MANAGEMENT OF COMBINED SEWER OVERFLOW RESEARCH PROGRAM CAPSTONE

    EPA Science Inventory


    Combined-sewer overflow (CSO) is a mixture of urban storm drainage, municipal-industrial wastewater, and subterranean infiltration. Untreated discharges of CSOs have caused substantial pollution impacts on the quality of receiving-water bodies. Problem constituents include ...

  5. Monitoring the performance of a storm water separating manifold with distributed temperature sensing.

    PubMed

    Langeveld, J G; de Haan, C; Klootwijk, M; Schilperoort, R P S

    2012-01-01

    Storm water separating manifolds in house connections have been introduced as a cost effective solution to disconnect impervious areas from combined sewers. Such manifolds have been applied by the municipality of Breda, the Netherlands. In order to investigate the performance of the manifolds, a monitoring technique (distributed temperature sensing or DTS) using fiber optic cables has been applied in the sewer system of Breda. This paper describes the application of DTS as a research tool in sewer systems. DTS proves to be a powerful tool to monitor the performance of (parts of) a sewer system in time and space. The research project showed that DTS is capable of monitoring the performance of house connections and identifying locations of inflow of both sewage and storm runoff. The research results show that the performance of storm water separating manifolds varies over time, thus making them unreliable.

  6. Integrated modelling for the evaluation of infiltration effects.

    PubMed

    Schulz, N; Baur, R; Krebs, P

    2005-01-01

    The objective of the present study is the estimation of the potential benefits of sewer pipe rehabilitation for the performance of the drainage system and the wastewater treatment plant (WWTP) as well as for the receiving water quality. The relation of sewer system status and the infiltration rate is assessed based on statistical analysis of 470 km of CCTV (Closed Circuit Television) inspected sewers of the city of Dresden. The potential reduction of infiltration rates and the consequent performance improvements of the urban wastewater system are simulated as a function of rehabilitation activities in the network. The integrated model is applied to an artificial system with input from a real sewer network. In this paper, the general design of the integrated model and its data requirements are presented. For an exemplary study, the consequences of the simulations are discussed with respect to the prioritisation of rehabilitation activities in the network.

  7. A new database on urban runoff pollution: comparison of separate and combined sewer systems.

    PubMed

    Brombach, H; Weiss, G; Fuchs, S

    2005-01-01

    For a long time people have questioned what the "best" sewer system is for limiting the pollution load released into the receiving waters. In this paper the traditional separate and combined sewer systems are compared using a pollution load balance. The investigation is based on measured concentration data for a range of pollutant parameters in the sewer from the new database "ATV-DVWK Datenpool 2001". The approach also accounted for the wastewater treatment plant outflow which contributes to the total pollutant load considerably. In spite of a number of neglected effects, the results show that the separate system is superior to the combined for some parameters only, such as nutrients, whereas for other parameters, e.g. heavy metals and COD, the combined system yields less total loads. Any uncritical preference of the separate system as a particularly advantageous solution is thus questionable. Individual investigations case by case are recommended.

  8. Investigation of the motion processes of wastewater in sewerage of high-rise buildings

    NASA Astrophysics Data System (ADS)

    Pomogaeva, Valentina; Metechko, Lyudmila; Prokofiev, Dmitry; Narezhnaya, Tamara

    2018-03-01

    When designing, constructing and operating sewage pipelines in high-rise buildings, issues of failure-free operation of a network arise. Investigation of the processes of wastewater moving allows identifying problem areas during operation, assessing the possibility of obstructions and breakdowns of plumbing traps on the gravity drainage sections of the pipeline. The article performs the schemes of the water outflow from the floor sewer into the riser, including the places where the riser is bent, of air delivery to the working riser under the change of the direction of drain movement with the dropout line set-up, with the installation of an automatic anti-vacuum valve, with the installation of the ventilation pipeline. Investigations of the process of sewage waste flow in a sewage riser were carried out, in order to select the appropriate structure. The authors consider structure features of some sections of sewerage in high-rise buildings. The exhaustion value in the riser is determined from the rarefactions that occur below the compressed cross-section of the riser and the loss of the air flow pressure coming from the atmosphere into the riser during the deflooding of the liquid. Preventing the formation of obstructions and breakdowns of plumbing traps is an integral part of sewage networks.

  9. Leveraging Spatial Data to Assess Where Sewers Leak and Impinge on Urban Water Quality

    NASA Astrophysics Data System (ADS)

    Holden, P. A.; Roehrdanz, P.; Lee, D. G.; Feraud, M.; Maier, M.; Means, J. C.; Snyder, S.

    2017-12-01

    In the modern urban water environment (UWE), engineered systems provide wastewater collection, treatment, and reuse; stormwater and graywater management; and potable water treatment, distribution and conservation. Underpinning such systems are physical, private and public, infrastructures whose integrities impinge on major goals of protecting groundwater and surface water resources, managing flooding, and securing safe drinking water. Here we study sanitary sewers, i.e. the main pipes in wastewater collection systems that improve public health by reducing pathogen exposure, and that afford reclaiming water for beneficial reuse. We ask: what is the relationship between sanitary sewer integrity and nearby water quality? Research methods include acquiring spatially defined sewer metadata that are analyzed using a published pipe leakage algorithm with variables of age, depth, materials of construction, length, diameter, slope, and nature of overburden. By executing the algorithm within a geographical information system (GIS), coupled with relating leakage probabilities to shallow groundwater table proximities—also digitally assembled, from well depth data—maps of wastewater exfiltration scores were produced for a city. Field sampling shallow groundwater allowed assessing concentrations of wastewater indicator compounds including personal care products and pharmaceuticals (PCPPs), and showing positive relationships between wastewater exfiltration scores and tryptophan-like fluorescence (TLF), reactive nitrogen species, an artificial sweetener acesulfame, and a stable isotope of oxygen (δ18O). The approach is extended to surface waters, where exfiltrating wastewater may transport from leaking sanitary sewers through the unsaturated zone to nearby storm drains or to storm drains that are submerged in contaminated groundwater. Spatially assessing sewer interactions within the UWE, as such, could aid urban infrastructure management and investment.

  10. Impervious surfaces and sewer pipe effects on stormwater runoff temperature

    NASA Astrophysics Data System (ADS)

    Sabouri, F.; Gharabaghi, B.; Mahboubi, A. A.; McBean, E. A.

    2013-10-01

    The warming effect of the impervious surfaces in urban catchment areas and the cooling effect of underground storm sewer pipes on stormwater runoff temperature are assessed. Four urban residential catchment areas in the Cities of Guelph and Kitchener, Ontario, Canada were evaluated using a combination of runoff monitoring and modelling. The stormwater level and water temperature were monitored at 10 min interval at the inlet of the stormwater management ponds for three summers 2009, 2010 and 2011. The warming effect of the ponds is also studied, however discussed in detail in a separate paper. An artificial neural network (ANN) model for stormwater temperature was trained and validated using monitoring data. Stormwater runoff temperature was most sensitive to event mean temperature of the rainfall (EMTR) with a normalized sensitivity coefficient (Sn) of 1.257. Subsequent levels of sensitivity corresponded to the longest sewer pipe length (LPL), maximum rainfall intensity (MI), percent impervious cover (IMP), rainfall depth (R), initial asphalt temperature (AspT), pipe network density (PND), and rainfall duration (D), respectively. Percent impervious cover of the catchment area (IMP) was the key parameter that represented the warming effect of the paved surfaces; sensitivity analysis showed IMP increase from 20% to 50% resulted in runoff temperature increase by 3 °C. The longest storm sewer pipe length (LPL) and the storm sewer pipe network density (PND) are the two key parameters that control the cooling effect of the underground sewer system; sensitivity analysis showed LPL increase from 345 to 966 m, resulted in runoff temperature drop by 2.5 °C.

  11. Modelling the effects of on-site greywater reuse and low flush toilets on municipal sewer systems.

    PubMed

    Penn, R; Schütze, M; Friedler, E

    2013-01-15

    On-site greywater reuse (GWR) and installation of water-efficient toilets (WET) reduce urban freshwater demand. Research on GWR and WET has generally overlooked the effects that GWR may have on municipal sewer systems. This paper discusses and quantifies these effects. The effects of GWR and WET, positive and negative, were studied by modelling a representative urban sewer system. GWR scenarios were modelled and analysed using the SIMBA simulation system. The results show that, as expected, the flow, velocity and proportional depth decrease as GWR increases. Nevertheless, the reduction is not evenly distributed throughout the day but mainly occurs during the morning and evening peaks. Examination of the effects of reduced toilet flush volumes revealed that in some of the GWR scenarios flows, velocities and proportional depths in the sewer were reduced, while in other GWR scenarios discharge volumes, velocities and proportional depths did not change. Further, it is indicated that as a result of GWR and installation of WET, sewer blockage rates are not expected to increase significantly. The results support the option to construct new sewer systems with smaller pipe diameters. The analysis shows that as the penetration of GWR systems increase, and with the installation of WET, concentrations of pollutants also increase. In GWR scenarios (when toilet flush volume is not reduced) the increase in pollutant concentrations is lower than the proportional reduction of sewage flow. Moreover, the results show that the spatial distribution of houses reusing GW does not significantly affect the parameters examined. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Emerging Contaminants in Wet-Weather Flow: Characterization and Treatability

    EPA Science Inventory

    An extensive literature review was conducted on the presence and magnitude of emerging contaminants (ECs) in wet-weather flow (WWF) including separate stormwater, combined sewer overflow (CSO), and sanitary sewer overflow (SSO). Although little information exists for stormwater ...

  13. SEWER AND TANK SEDIMENT FLUSHING: CASE STUDIES

    EPA Science Inventory

    The objective of the report summarized here is to demonstrate that sewer system and storage tank flushing that reduces sediment deposition and accumulation is of prime importance to optimizing performance, maintaining structural integrity, and minimizing pollution of receiving wa...

  14. VERIFICATION OF HIGH-RATE DISINFECTION TECHNOLOGIES FOR WET-WEATHER FLOW APPLICATIONS

    EPA Science Inventory

    This paper describes the critical components of the USEPA's Environmental Technology Verification Program for two specific technologies categories: ultraviolet disinfection technologies for treating combined sewer overflow (CSO) and sanitary sewer overflow (SSO), and; and mechani...

  15. COLLABORATIVE RESEARCH ON URBAN BEST MANAGEMENT PRACTICES

    EPA Science Inventory

    Storm driven wet weather flow (WWF) which includes combined sewer and sanitary sewer overflows and stormwater discharges are a leading cause of water-quality impairment. Problem constituents in WWF include pathogens, solids, nutrients, and toxicants. New technologies to control...

  16. 3. ENVIRONMENT, FROM WEST, SHOWING BOSTON STREET BRIDGE CARRYING BOSTON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. ENVIRONMENT, FROM WEST, SHOWING BOSTON STREET BRIDGE CARRYING BOSTON STREET OVER HARRIS CREEK SEWER, WITH PORTION OF AMERICAN CAN COMPANY COMPLEX - Boston Street Bridge, Spanning Harris Creek Sewer at Boston Street, Baltimore, Independent City, MD

  17. D.C. Municipal Separate Storm Sewer System (MS4)

    EPA Pesticide Factsheets

    This permit covers all areas within the jurisdictional boundary of the District of Columbia served by, or otherwise contributing to discharges from, the Municipal Separate Storm Sewer System (MS4) owned or operated by the District of Columbia.

  18. OPIMIZATION OF COMBINED SEWER OVERFLOW CONTROL SYSTEMS

    EPA Science Inventory

    The highly variable and intermittent pollutant concentrations and flowrates associated with wet-weather events in combined sewersheds necessitates the use of storage-treatment systems to control pollution. A strategy should be adopted to develop an optimized combined sewer overfl...

  19. Condition Assessment of Wastewater Collection Systems

    EPA Science Inventory

    Municipal sanitary sewer collection systems play a critical role in protecting public health in our municipalities. They are designed to convey wastewater from their sources to a wastewater treatment plant (WWTP). Collection systems consist of house service laterals, sewers, pu...

  20. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    EPA Science Inventory

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  1. Antimicrobial Effects of Free Nitrous Acid on Desulfovibrio vulgaris: Implications for Sulfide-Induced Corrosion of Concrete

    PubMed Central

    Gao, Shu-Hong; Ho, Jun Yuan; Fan, Lu; Richardson, David J.; Yuan, Zhiguo

    2016-01-01

    ABSTRACT Hydrogen sulfide produced by sulfate-reducing bacteria (SRB) in sewers causes odor problems and asset deterioration due to the sulfide-induced concrete corrosion. Free nitrous acid (FNA) was recently demonstrated as a promising antimicrobial agent to alleviate hydrogen sulfide production in sewers. However, details of the antimicrobial mechanisms of FNA are largely unknown. Here, we report the multiple-targeted antimicrobial effects of FNA on the SRB Desulfovibrio vulgaris Hildenborough by determining the growth, physiological, and gene expression responses to FNA exposure. The activities of growth, respiration, and ATP generation were inhibited when exposed to FNA. These changes were reflected in the transcript levels detected during exposure. The removal of FNA was evident by nitrite reduction that likely involved nitrite reductase and the poorly characterized hybrid cluster protein, and the genes coding for these proteins were highly expressed. During FNA exposure, lowered ribosome activity and protein production were detected. Additionally, conditions within the cells were more oxidizing, and there was evidence of oxidative stress. Based on an interpretation of the measured responses, we present a model depicting the antimicrobial effects of FNA on D. vulgaris. These findings provide new insight for understanding the responses of D. vulgaris to FNA and will provide a foundation for optimal application of this antimicrobial agent for improved control of sewer corrosion and odor management. IMPORTANCE Hydrogen sulfide produced by SRB in sewers causes odor problems and results in serious deterioration of sewer assets that requires very costly and demanding rehabilitation. Currently, there is successful application of the antimicrobial agent free nitrous acid (FNA), the protonated form of nitrite, for the control of sulfide levels in sewers (G. Jiang et al., Water Res 47:4331–4339, 2013, http://dx.doi.org/10.1016/j.watres.2013.05.024). However, the details of the antimicrobial mechanisms of FNA are largely unknown. In this study, we identified the key responses (decreased anaerobic respiration, reducing FNA, combating oxidative stress, and shutting down protein synthesis) of Desulfovibrio vulgaris Hildenborough, a model sewer corrosion bacterium, to FNA exposure by examining the growth, physiological, and gene expression changes. These findings provide new insight and underpinning knowledge for understanding the responses of D. vulgaris to FNA exposure, thereby benefiting the practical application of FNA for improved control of sewer corrosion and odor. PMID:27371588

  2. Localization of groundwater infiltration in the combined sewers of Brussels by stable isotopes measurements (δ18O, δD) by Cavity Ring Down Spectroscopy.

    NASA Astrophysics Data System (ADS)

    De Bondt, Kevin; Claeys, Philippe

    2014-05-01

    In the last 20 years research has been conducted to quantify the infiltration of groundwater into the sewers. This groundwater, called parasitic water, increases the volume of waste-water to be treated and consequently the cost of this treatment. Moreover, in the case of combined sewer systems, the parasitic water also limits the sewer capacity and indirectly increases the risks of combined sewer overflows and floods. The infiltration of groundwater occurs trough cracks, sewer collapses and from direct connections with old springs. Different methods quantify the intrusion of parasitic water. Among these, the use of the stable isotopes of water (δ18O & δD) shows good result in catchments or cities close to Mountainous regions (example from Lyon, Zurich), where isotopic signals vary significantly because of continental and altitude effects. However many cities, such as Brussels, are located in more oceanic settings and theoretically offer less potential for the application of the stable isotopes method. In the case of Brussels, river-water from the Meuse is used to produce domestic-water. The catchment of this river extends into the Ardennes, which are affected by slightly different climatic conditions. δ18O & δD analyzes of groundwater from the main aquifer (Ledo-Paniselian-Brusselian) and domestic-water from the Callois reservoir fed by the Meuse River show sufficient isotopic differences in the south of Brussels, but only during the summer. The discrimination potential is better with δD than with δ18O. The improvement of δD measurements (precision, costs,...) brought by Cavity Ring Down Spectroscopy largely contributes to the potential of using stable isotopes method to trace water in Brussels. The first campaigns in the sewers also show a little enrichment (in heavy isotopes) of the waste-water in comparison with the reservoir waters and tap waters. This increases the potential of the method but constrains the sampling to pure waste-water in sewer segments without infiltration generally localized upstream. Anyway, it is in the localization of parasitic water entrance from upstream to downstream that the stable isotopes method is the most powerful. Other methods (e.g. minimum night flow,...) are available at the treatment plants or at flow measurement stations downstream but will not be able to localize parasitic water intrusion towards old springs.

  3. Case Study Application of Determining End of Physical Life Using Survival Analysis (WERF Report INFR2R11b)

    EPA Science Inventory

    Abstract: This case study application provides discussion on a selected application of advanced concepts, included in the End of Asset Life Reinvestment decision-making process tool, using Milwaukee Metropolitan Sewer District (MMSD) pump and motor data sets. The tool provides s...

  4. Real-time Control of sewer pumps by using ControlNEXT to smooth inflow at Waste Water Treatment Plant Garmerwolde

    NASA Astrophysics Data System (ADS)

    van Heeringen, Klaas-Jan; van Nooijen, Ronald; Kooij, Kees; Postma, Bokke

    2016-04-01

    The Garmerwolde waste water treatment plant (WWTP) in the Groningen area of the Netherlands, receives waste water from a large area. That waste water is collected from many sewer systems and transported to the WWTP through pressurized pipes. The supply of waste water to the WWTP is relatively low and very irregular during dry-weather conditions, resulting in a random pattern of flows. This irregularity is the effect of the local control of the pumps, where the pumps are individually operated as an on/off control based on the water levels in the connected sewer system. The influent may change from zero to high values in a few minutes. The treatment processes at the WWTP are negatively influenced by this irregularity, which ends in high costs for energy and use of chemicals. The ControlNEXT central control system is used to control the 5 largest pump stations, such that the total inflow at the WWTP becomes much smoother. This results in a reduction of operational costs of about 10%. The control algorithm determines whether the actual condition is dry or wet, based on real-time radar precipitation images and the rainfall forecast product HiRLAM. All actual data is also collected and validated, like water levels, pump operations and pump availability. This data management is done using Delft-FEWS. If the situation is identified as "wet", the sewer systems are emptied as far as possible to create maximum storage. If the situation is "dry" (and of course there is a dead band between dry and wet), the pumps are operated such that the total inflow into the WWTP is smoothed. This is done with a Greedy algorithm, developed by Delft University of Technology. The algorithm makes a plan for the next 24 hours (as the daily inflow has a typical daily pattern) and generally stores some water volume in the sewer systems during the day to be able to continue operations during the night. The pumps are controlled with a time step of 5 minutes, where ControlNEXT manages the communication of pump operation setpoints to the SCADA system. In case of failing communication, backup procedures are programmed in the PLC of the pump stations. In that case the old on/off operation based on local water levels will be used. The system has been operational since January 2016 and has been monitored since then. In addition to monitoring the positive effect on the inflow at the WWTP, an important issue is the possible sedimentation in the sewer systems. This will be monitored too.

  5. A catchment-scale groundwater model including sewer pipe leakage in an urban system

    NASA Astrophysics Data System (ADS)

    Peche, Aaron; Fuchs, Lothar; Spönemann, Peter; Graf, Thomas; Neuweiler, Insa

    2016-04-01

    Keywords: pipe leakage, urban hydrogeology, catchment scale, OpenGeoSys, HYSTEM-EXTRAN Wastewater leakage from subsurface sewer pipe defects leads to contamination of the surrounding soil and groundwater (Ellis, 2002; Wolf et al., 2004). Leakage rates at pipe defects have to be known in order to quantify contaminant input. Due to inaccessibility of subsurface pipe defects, direct (in-situ) measurements of leakage rates are tedious and associated with a high degree of uncertainty (Wolf, 2006). Proposed catchment-scale models simplify leakage rates by neglecting unsaturated zone flow or by reducing spatial dimensions (Karpf & Krebs, 2013, Boukhemacha et al., 2015). In the present study, we present a physically based 3-dimensional numerical model incorporating flow in the pipe network, in the saturated zone and in the unsaturated zone to quantify leakage rates on the catchment scale. The model consists of the pipe network flow model HYSTEM-EXTAN (itwh, 2002), which is coupled to the subsurface flow model OpenGeoSys (Kolditz et al., 2012). We also present the newly developed coupling scheme between the two flow models. Leakage functions specific to a pipe defect are derived from simulations of pipe leakage using spatially refined grids around pipe defects. In order to minimize computational effort, these leakage functions are built into the presented numerical model using unrefined grids around pipe defects. The resulting coupled model is capable of efficiently simulating spatially distributed pipe leakage coupled with subsurficial water flow in a 3-dimensional environment. References: Boukhemacha, M. A., Gogu, C. R., Serpescu, I., Gaitanaru, D., & Bica, I. (2015). A hydrogeological conceptual approach to study urban groundwater flow in Bucharest city, Romania. Hydrogeology Journal, 23(3), 437-450. doi:10.1007/s10040-014-1220-3. Ellis, J. B., & Revitt, D. M. (2002). Sewer losses and interactions with groundwater quality. Water Science and Technology, 45(3), 195-202. itwh (2002). Modellbeschreibung, Institut für technisch-wissenschaftliche Hydrologie GmbH, Hannover. Karpf, C. & Krebs, P. (2013). Modelling of groundwater infiltration into sewer systems. Urban Water Journal, 10:4, 221-229, DOI: 10.1080/1573062X.2012.724077. Kolditz, O., Bauer, S. et al. (2012). OpenGeoSys: an open source initiative for numerical simulation of thermo-hydro-mechanical/chemical (THM/C) processes in porous media. Env. Earth Sci. 67(2):589-599. Wolf, L., Held, I., Eiswirth, M., & Hötzl, H. (2004). Impact of leaky sewers on groundwater quality. Acta Hydrochimica et Hydrobiologica, 32(4-5), 361-373. doi:10.1002/aheh.200400538. Wolf, L. (2006). Influence of leaky sewer systems on groundwater resources beneath the city of Rastatt, Germany. Dissertation, University of Karlsruhe.

  6. FLOCCULATION-FLOTATION AIDS FOR TREATMENT OF COMBINED SEWER OVERFLOWS

    EPA Science Inventory

    The objectives of this study were to investigate the flocculation/flotation characteristics of combined sewer overflow through laboratory and field testing. The concept involves the introduction of chemicals and buoyant flotation aids into the overflow and the subsequent cofloccu...

  7. REAL TIME CONTROL OF SEWERS: US EPA MANUAL

    EPA Science Inventory

    The problem of sewage spills and local flooding has traditionally been addressed by large scale capital improvement programs that focus on construction alternatives such as sewer separation or construction of storage facilities. The cost of such projects is often high, especiall...

  8. U.S. EPA CSO CAPSTONE REPORT: CONTROL SYSTEM OPTIMIZATION

    EPA Science Inventory

    An optimized combined sewer overflow (CSO) requires a storage treatment system because storm flow in the combined sewer system is intermittent and highly variable in both pollutant concentration and flow rate. Storage and treatment alternatives are strongly influenced by input...

  9. SSOAP Toolbox Enhancements and Case Study

    EPA Science Inventory

    Recognizing the need for tools to support the development of sanitary sewer overflow (SSO) control plans, in October 2009 the U.S. Environmental Protection Agency (EPA) released the first version of the Sanitary Sewer Overflow Analysis and Planning (SSOAP) Toolbox. This first ve...

  10. 1. ENVIRONMENT, FROM SOUTH, SHOWING BOSTON STREET BRIDGE CARRYING BOSTON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. ENVIRONMENT, FROM SOUTH, SHOWING BOSTON STREET BRIDGE CARRYING BOSTON STREET OVER HARRIS CREEK SEWER OUTLET AT NORTHWEST BRANCH OF PATAPSCO RIVER (BALTIMORE HARBOR) - Boston Street Bridge, Spanning Harris Creek Sewer at Boston Street, Baltimore, Independent City, MD

  11. OVERVIEW OF EPA'S WET-WEATHER FLOW RESEARCH PROGRAM

    EPA Science Inventory

    Surface waters receive three types of urban wet-weather flow discharges: combined-sewer overflow (CSO), stormwater, and sanitary-sewer overflow (SSO); all are principally untreated discharges that occur during storm-flow events. WWFs have proven to generate a substantial amount o...

  12. USING VISUAL PLUMES PREDICTIONS TO MODULATE COMBINED SEWER OVERFLOW (CSO) RATES

    EPA Science Inventory

    High concentrations of pathogens and toxic residues in creeks and rivers can pose risks to human health and ecological systems. Combined Sewer Overflows (CSOs) discharging into these watercourses often contribute significantly to elevating pollutant concentrations during wet weat...

  13. Notification: Review of Atlanta Combined Sewer Overflow Consent Decree

    EPA Pesticide Factsheets

    Project #OPE-FY17-0014, March 30, 2017. The EPA OIG plans to begin a review of EPA Region 4’s oversight of the Atlanta combined sewer overflow consent decree. For more information, please click on the link above.

  14. 40 CFR 35.927-2 - Sewer system evaluation survey.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act... transportation and treatment for each defined source of infiltration/inflow. (b) A report shall summarize the... sewer system to eliminate all defined excessive infiltration/inflow. ...

  15. pH dynamics in sewers and its modeling.

    PubMed

    Sharma, Keshab; Ganigue, Ramon; Yuan, Zhiguo

    2013-10-15

    pH variation in sewers has a significant effect on hydrogen sulfide production and emissions, and hence its accurate prediction is critical for the optimization of mitigation strategies. In this study, the nature and dynamics of pH variation in a sewer system is examined. Three sewer systems collecting domestic wastewater were monitored, with pH in all cases showing large diurnal variations. pH in fresh sewage in all three cases had a very similar trend with maximum pH in the range of 8.5-8.7. pH variation in fresh sewage followed the same pattern as the sewage flow rate, suggesting that sewage pH is influenced by household water use. Nitrogen content of the wastewater was found to be the most influential factor causing pH variation in fresh sewage, with the total ammonium concentration variation well correlated with the pH variation. A methodology for predicting pH variation in sewers is developed and calibration protocols proposed. The methodology, which is based on the concept of charge balance, was validated using titration curves and field pH data. Measurement of the total ammonium concentration in fresh sewage was found necessary and adequate for the calibration of the charge balance-based pH model. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Palatability and efficacy of bromadiolone rodenticide block bait previously exposed to environmental conditions.

    PubMed

    Nakagawa, Lia; de Masi, Eduardo; Narciso, Emerson; Neto, Hildebrando Montenegro; Papini, Solange

    2015-10-01

    In São Paulo city, rodent infestation is considered to be a serious public health problem and is the object of a municipal rodent control programme. One of the most important routine methods involves baiting in sewers, using bromadiolone block bait in a pulsed baiting strategy. It has been observed that, after each pulse, bait is not always consumed, and its appearance is altered, which has led to concerns about efficacy. We assessed whether exposure to sewer conditions influences the palatability and efficacy of rodenticide baits to Norway rats (Rattus norvegicus). Baits containing bromadiolone as active ingredient were placed in sewers, removed after 30 days and offered to rats in a two-choice food trial and a no-choice food trial. The appearance of the rodenticide baits changed after 30 days exposure to sewer conditions, but they continued to be palatable and effective against rats. The level of mortality was considered to be satisfactory, 75% in the two-choice food trial and 100% in the no-choice food trial. Results support the reuse of rodenticide block bait in rodent control. It seems to be justified to continue using/reuse baits even when their appearance has changed after 30 days exposure in sewer systems. © 2014 Society of Chemical Industry.

  17. Trace element carriers in combined sewer during dry and wet weather: an electron microscope investigation.

    PubMed

    El Samrani, A G; Lartiges, B S; Ghanbaja, J; Yvon, J; Kohler, A

    2004-04-01

    The nature of trace element carriers contained in sewage and combined sewer overflow (CSO) was investigated by TEM-EDX-Electron diffraction and SEM-EDX. During dry weather, chalcophile elements were found to accumulate in sewer sediments as early diagenetic sulfide phases. The sulfurization of some metal alloys was also evidenced. Other heavy metal carriers detected in sewage include metal alloys, some iron oxihydroxide phases and neoformed phosphate minerals such as anapaite. During rain events, the detailed characterization of individual mineral species allowed to differentiate the contributions from various specific sources. Metal plating particles, barite from automobile brake, or rare earth oxides from catalytic exhaust pipes, originate from road runoff, whereas PbSn alloys and lead carbonates are attributed to zinc-works from roofs and paint from building siding. Soil contribution can be traced by the presence of clay minerals, iron oxihydroxides, zircons and rare earth phosphates. However, the most abundant heavy metal carriers in CSO samples were the sulfide particles eroded from sewer sediments. The evolution of relative abundances of trace element carriers during a single storm event, suggests that the pollution due to the "first flush" effect principally results from the sewer stock of sulfides and previously deposited metal alloys, rather than from urban surface runoff.

  18. Public Infrastructure Disparities and the Microbiological and Chemical Safety of Drinking and Surface Water Supplies in a Community Bordering a Landfill

    PubMed Central

    Heaney, Christopher D.; Wing, Steve; Wilson, Sacoby M.; Campbell, Robert L.; Caldwell, David; Hopkins, Barbara; O’Shea, Shannon; Yeatts, Karin

    2015-01-01

    The historically African-American Rogers-Eubanks community straddles unincorporated boundaries of two municipalities in Orange County, North Carolina, and predates a regional landfill sited along its border in 1972. Community members from the Rogers-Eubanks Neighborhood Association (RENA), concerned about deterioration of private wells and septic systems and a lack of public drinking water and sewer services, implemented a community-driven research partnership with university scientists and community-based organizations to investigate water and sewer infrastructure disparities and the safety of drinking and surface water supplies. RENA drafted memoranda of agreement with partners and trained community monitors to collect data (inventory households, map water and sewer infrastructure, administer household water and sewer infrastructure surveys, and collect drinking and surface water samples). Respondents to the surveys reported pervasive signs of well vulnerability (100%) and septic system failure (68%). Each 100-m increase in distance from the landfill was associated with a 600 most probable number/100 mL decrease in enterococci concentrations in surface water (95% confidence interval = −1106, −93). Pervasive private household water and sewer infrastructure failures and poor water quality were identified in this community bordering a regional landfill, providing evidence of a need for improved water and sanitation services. PMID:23858663

  19. Assessment of pollutant load emission from combined sewer overflows based on the online monitoring.

    PubMed

    Brzezińska, Agnieszka; Zawilski, Marek; Sakson, Grażyna

    2016-09-01

    Cities equipped with combined sewer systems discharge during wet weather a lot of pollutants into receiving waters by combined storm overflows (CSOs). According to the Polish legislation, CSOs should be activated no more than ten times per year, but in Lodz, most of the 18 existing CSOs operate much more frequently. To assess the pollutant load emitted by one of the existing CSOs, the sensors for measuring the concentration of total suspended solids (SOLITAX sc) and dissolved chemical oxygen demand (UVAS plus) installed in the overflow chamber as well as two flowmeters placed in the outflow sewer were used. In order to check the data from sensors, laboratory tests of combined wastewater quality were conducted simultaneously. For the analysis of the total pollutant load emitted from the overflow, the raw data was denoised using the Savitzky-Golay method. Comparing the load calculated from the analytical results to online smoothed measurements, negligible differences were found, which confirms the usefulness of applying the sensors in the combined sewer system. Online monitoring of the quantity and quality of wastewater emitted by the combined sewer overflows to water receivers, provides a considerable amount of data very useful for combined sewerage upgrading based on computer modelling, and allows for a significant reduction of laboratory analysis.

  20. Effect of the spatiotemporal variability of rainfall inputs in water quality integrated catchment modelling for dissolved oxygen concentrations

    NASA Astrophysics Data System (ADS)

    Moreno Ródenas, Antonio Manuel; Cecinati, Francesca; ten Veldhuis, Marie-Claire; Langeveld, Jeroen; Clemens, Francois

    2016-04-01

    Maintaining water quality standards in highly urbanised hydrological catchments is a worldwide challenge. Water management authorities struggle to cope with changing climate and an increase in pollution pressures. Water quality modelling has been used as a decision support tool for investment and regulatory developments. This approach led to the development of integrated catchment models (ICM), which account for the link between the urban/rural hydrology and the in-river pollutant dynamics. In the modelled system, rainfall triggers the drainage systems of urban areas scattered along a river. When flow exceeds the sewer infrastructure capacity, untreated wastewater enters the natural system by combined sewer overflows. This results in a degradation of the river water quality, depending on the magnitude of the emission and river conditions. Thus, being capable of representing these dynamics in the modelling process is key for a correct assessment of the water quality. In many urbanised hydrological systems the distances between draining sewer infrastructures go beyond the de-correlation length of rainfall processes, especially, for convective summer storms. Hence, spatial and temporal scales of selected rainfall inputs are expected to affect water quality dynamics. The objective of this work is to evaluate how the use of rainfall data from different sources and with different space-time characteristics affects modelled output concentrations of dissolved oxygen in a simplified ICM. The study area is located at the Dommel, a relatively small and sensitive river flowing through the city of Eindhoven (The Netherlands). This river stretch receives the discharge of the 750,000 p.e. WWTP of Eindhoven and from over 200 combined sewer overflows scattered along its length. A pseudo-distributed water quality model has been developed in WEST (mikedhi.com); this is a lumped-physically based model that accounts for urban drainage processes, WWTP and river dynamics for several pollutant typologies. Different rainfall products are tested: 1) Block kriging of a single reliable rain gauge, 2) Block kriging product from a network of 13 rain gauges and, 3) Universal block kriging with 13 rain gauges and KNMI weather radar estimates as a covariate. Different temporal accumulation levels are compared ranging from 10min to 1h. A geostatistical approach is used to allocate the prediction of the rainfall input in each of the urban hydrological units composing the model. The change in model performance is then assessed by contrasting it with dissolved oxygen monitoring data in a series of events.

  1. Contribution of Geographic Information Systems and location models to planning of wastewater systems.

    PubMed

    Leitão, J P; Matos, J S; Gonçalves, A B; Matos, J L

    2005-01-01

    This paper presents the contributions of Geographic Information Systems (GIS) and location models towards planning regional wastewater systems (sewers and wastewater treatment plants) serving small agglomerations, i.e. agglomerations with less than 2,000 inhabitants. The main goal was to develop a decision support tool for tracing and locating regional wastewater systems. The main results of the model are expressed in terms of number, capacity and location of Wastewater Treatment Plants (WWTP) and the length of main sewers. The decision process concerning the location and capacity of wastewater systems has a number of parameters that can be optimized. These parameters include the total sewer length and number, capacity and location of WWTP. The optimization of parameters should lead to the minimization of construction and operation costs of the integrated system. Location models have been considered as tools for decision support, mainly when a geo-referenced database can be used. In these cases, the GIS may represent an important role for the analysis of data and results especially in the preliminary stage of planning and design. After selecting the spatial location model and the heuristics, two greedy algorithms were implemented in Visual Basic for Applications on the ArcGIS software environment. To illustrate the application of these algorithms a case study was developed, in a rural area located in the central part of Portugal.

  2. Self-monitoring of water quality in sewer systems using absorbance of ultraviolet and visible light.

    PubMed

    Ruban, G; Ruperd, Y; Laveau, B; Lucas, E

    2001-01-01

    Continuous pollution measurement is interesting to optimize the operation of sanitary facilities as well as to minimize the stormwater discharges. An experimental study was carried out for the determination of Suspended Solids (SS) and Chemical Oxygen Demand (COD) concentrations in combined sewers using ultraviolet and visible absorbances. The maintenance of the measurement system requires six hours a month for the cleaning of the hydraulic feeding system and adjustment of the optical device. The feeding system developed increased the representativeness and reliability of the pollution measurement, but needs to be validated on other measurement sites. The determination of SS concentrations from visible absorbances requires 2 calibration curves for dry and rainy weather respectively. The corresponding accuracies appear satisfactory when compared with the results of standard sampling/laboratory analysis. The accuracy of COD determination from ultraviolet absorbance is less satisfactory, but could perhaps be improved taking into account another parameter. Then the optical measurement of SS and COD is interesting to determine average or long term pollution loads, for example the yearly impact of urban stormwater discharges. With this kind of continuous and on-line measurement, it is possible to react with short delay to unexpected phenomena which could damage the environment or water treatment efficiency.

  3. MANUAL: REAL TIME CONTROL OF COMBINED SEWERS

    EPA Science Inventory

    Managers, engineers, and operators of combined urban sewer systems are faced with difficult problems related to the operation and maintenance of their facilities. In addition to the issues related to the operation and upkeep of the system, many sewerage agencies are facing increa...

  4. Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas

    EPA Science Inventory

    While sewer renewal technologies currently being used for the repair, replacement and/or rehabilitation of deteriorating wastewater collection systems are generally effective, there is still room for improvement of existing technologies and for the development of new technologies...

  5. Urban Runoff and Combined Sewer Overflow.

    ERIC Educational Resources Information Center

    Field, Richard; Gardner, Bradford B.

    1978-01-01

    Presents a literature review of wastewater treatment, covering publications of 1976-77. This review includes areas such as: (1) urban runoff quality and quantity; (2) urban hydrology; (3) management practices; and (4) combined sewer overflows. A list of 140 references is also presented. (HM)

  6. Colorado River Sewer System Joint Venture to Upgrade Wastewater System

    EPA Pesticide Factsheets

    SAN FRANCISCO -Today, the Colorado River Sewer System Joint Venture, located in Parker, Ariz. entered into an agreement with the EPA to upgrade their wastewater treatment system to meet stringent water quality standards. The cost of the upgrade is ap

  7. High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)

    EPA Science Inventory

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...

  8. EXFILTRATION IN SEWER SYSTEMS: IS IT A NATIONAL PROBLEM?

    EPA Science Inventory

    Many municipalities throughout the US have sewerage systems (separate and combined) that may experience exfiltration of untreated wastewater. This study was conducted to focus on the magnitude of the exfiltration problem from sewer pipes on a national basis. The method for estima...

  9. US EPA CSO CAPSTONE REPORT: THE CSO PROBLEM

    EPA Science Inventory

    The history of combined sewer systems (CSS) and combined sewer overflows (CSOs) in the US provides unique insights into the complex challenge faced in reducing and eliminating their adverse environmental effects. The evolution of the "modern" CSS shows how early urban drainag sys...

  10. Incorporating Storm Sewer Exfiltration into SWMM: Proof of Concept

    EPA Science Inventory

    This study evaluates the peak flow and volume reduction achieved by exfiltration from a perforated storm sewer in an urban catchment. There are three related objectives: [1] quantify peak flow and volume reduction; [2] demonstrate adaptability to climate change; and [3] evaluate ...

  11. EXFILTRATION IN SANITARY SEWER SYSTEMS IN THE U.S.

    EPA Science Inventory

    Many municipalities throughout the US have sewerage systems (separate and combined) that may experience exfiltration of untreated wastewater. This study was conducted to focus on the magnitude of the exfiltration problem from sewer pipes on a national basis. The method for estima...

  12. Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas - slides

    EPA Science Inventory

    While sewer renewal technologies currently being used for the repair, replacement and/or rehabilitation of deteriorating wastewater collection systems are generally effective, there is still room for improvement of existing technologies and for the development of new technologies...

  13. CHALLENGES OF COMBINED SEWER OVERFLOW DISINFECTION BY ULTRAVIOLET LIGHT IRRADIATION

    EPA Science Inventory

    This article examines the performance and effectiveness of ultraviolet (UV) light irradiation for disinfection of combined sewer overflow (CSO). Due to the negative impact of conventional water disinfectants on aquatic life, new agents (e.g., UV light) are being investigated for ...

  14. NPDES Permit for Air Force Academy Municipal Separate Storm Sewer System in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-R042007, the U.S. Air Force Academy is authorized to discharge from all municipal separate storm sewer system outfalls to the receiving waters specified in the permit in El Paso County, Colorado.

  15. EVALUATING INNOVATIVE STORMWATER TREATMENT TECHNOLOGIES UNDER THE ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM

    EPA Science Inventory

    Assessing, controlling, and treating combined-sewer overflows (CSO), sanitary sewer overflows (SSO), and urban stormwater runoff have become priorities for communities. Improved and cost effective treatment technologies are needed to reduce the adverse impacts that wet weather f...

  16. PERFORMANCE OF OZONE AS A DISINFECTANT FOR COMBINED SEWER OVERFLOW

    EPA Science Inventory

    Disinfection of combined sewer overflow (CSO) minimizes the amount of disease-causing microorganisms (pathogens) released into receiving waters. Currently, the primary disinfecting agent used in the US for wastewater treatment is chlorine (Cl2); however, Cl2 produces problems in ...

  17. 78 FR 18629 - Notice of Lodging of Proposed Partial Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ... sewer system, perform initial work over the next four years to address sewer overflows, develop a..., DC 20044- 7611. Please enclose a check or money order for $84.50 (25 cents per page reproduction cost...

  18. ULTRAVIOLET LIGHT DISINFECTION OF COMBINED SEWER OVERFLOW (NEW ORLEANS)

    EPA Science Inventory

    The objective of this state-of-the-art review is to examine the performance and effectiveness of ultraviolet (UV) light disinfection for combined sewer overflow (CSO) applications. Topics presented include the use of UV light as a disinfecting agent, its practical applications, d...

  19. Enforcement to Address Sewer Overflows | Eliminating ...

    EPA Pesticide Factsheets

    2017-04-10

    EPA's compliance goal is to eliminate sanitary sewer overflows (SSOs) from municipal collection systems and to ensure that wastewater is being conveyed to treatment plants in accordance with the requirements of the Clean Water Act. To eliminate SSOs, EPA uses a mix of compliance and enforcement tools.

  20. Multistakeholder Evaluation of Condominial Sewer Services

    ERIC Educational Resources Information Center

    Nance, Earthea

    2005-01-01

    A multistakeholder evaluation procedure is presented to address the many challenges in evaluating the performance of condominial sewer projects in Brazil. Condominial sewerage is a promising appropriate technology that is coproduced by users and public agencies, but little is known about project performance. This article shows that…

  1. CHARACTERIZATION OF METALS IN RUNOFF FROM RESIDENTIAL AND HIGHWAY STORM SEWERS

    EPA Science Inventory

    Stormwater runoff was sampled from six storm sewer outfalls in residential and highway settings in Monmouth County, NJ to determine the colloidal and dissolved metal concentrations. Heavy metals, common pollutants in natural waters and stormwater, are known to associate with par...

  2. ENVIRONMENTAL FOOTPRINT OF PHARMACEUTICALS - THE SIGNIFICANCE OF FACTORS BEYOND DIRECT EXCRETION TO SEWERS

    EPA Science Inventory

    The combined excretion of active pharmaceutical ingredients (APIs) via urine and feces is considered the primary route by which APIs from human pharmaceuticals enter the environment. Disposal of unwanted, leftover medications by flushing into sewers has been considered a secondar...

  3. EPA Office of Research and Development - I/I Research Information Update

    EPA Science Inventory

    The Nation’s sanitary sewer infrastructure is aging, and is currently one of the top national water program priorities. The U.S. Environmental Protection Agency (EPA) developed the Sanitary Sewer Overflow Analysis and Planning (SSOAP) Toolbox to assist communities in devel...

  4. 33 CFR 238.6 - General policy.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system of pipes traditionally recognized as a storm drainage system. Flood damage reduction works... ditches with carrying capacities typical of storm sewer pipes. Location of political boundaries will not... the Corps of Engineers. (2) Construction of storm sewer systems and components thereof will be a non...

  5. 33 CFR 238.6 - General policy.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... system of pipes traditionally recognized as a storm drainage system. Flood damage reduction works... ditches with carrying capacities typical of storm sewer pipes. Location of political boundaries will not... the Corps of Engineers. (2) Construction of storm sewer systems and components thereof will be a non...

  6. 33 CFR 238.6 - General policy.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... system of pipes traditionally recognized as a storm drainage system. Flood damage reduction works... ditches with carrying capacities typical of storm sewer pipes. Location of political boundaries will not... the Corps of Engineers. (2) Construction of storm sewer systems and components thereof will be a non...

  7. 33 CFR 238.6 - General policy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system of pipes traditionally recognized as a storm drainage system. Flood damage reduction works... ditches with carrying capacities typical of storm sewer pipes. Location of political boundaries will not... the Corps of Engineers. (2) Construction of storm sewer systems and components thereof will be a non...

  8. 33 CFR 238.6 - General policy.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system of pipes traditionally recognized as a storm drainage system. Flood damage reduction works... ditches with carrying capacities typical of storm sewer pipes. Location of political boundaries will not... the Corps of Engineers. (2) Construction of storm sewer systems and components thereof will be a non...

  9. State of Technology Report for Force Main Rehabilitation

    EPA Science Inventory

    Force mains that carry sewage flows under pressure represent a special set of challenges for sewer rehabilitation. Force mains represent about 7.5% of the wastewater system and they typically use materials that are not commonly used in gravity sewer systems. Ductile iron (DI), ...

  10. LAND USE AND SEASONAL EFFECTS ON URBAN STORMWATER RUNOFF MICROORGANISM CONCENTRATIONS

    EPA Science Inventory

    Stormwater samples collected from storm sewers draining small municipal separate storm sewer systems shown to be free of cross connections within an urban watershed dominated by a single land use were analyzed for pathogens (Pseudomonas aeruginosa and Staphylococcus aureus) and i...

  11. EFFECTS OF LAND USE AND SEASON ON MICROORGANISM CONCENTRATIONS IN URBAN STORMWATER RUNOFF

    EPA Science Inventory

    This study investigated differences in pathogen and indicator organism concentrations in stormwater runoff between different urban land uses and seasons. Stormwater samples collected from storm sewers draining small municipal separate storm sewer systems shown to be free of cros...

  12. MODELS TO ESTIMATE VOLATILE ORGANIC HAZARDOUS AIR POLLUTANT EMISSIONS FROM MUNICIPAL SEWER SYSTEMS

    EPA Science Inventory

    Emissions from municipal sewers are usually omitted from hazardous air pollutant (HAP) emission inventories. This omission may result from a lack of appreciation for the potential emission impact and/or from inadequate emission estimation procedures. This paper presents an analys...

  13. SEMINAR PUBLICATION: NATIONAL CONFERENCE ON SANITARY SEWER OVERFLOWS (SSOS)

    EPA Science Inventory

    This seminar publication presents selected peer-reviewed papers from the conference. Thousands of municipalities across the nation are serviced by separate sanitary sewer systems. A chronic problem that faces many of these systems is the occurrence of SSOs, caused mainly by the i...

  14. Re-examination of the 1994 and subsequent sewer and culvert installations of various pipe types, sizes and depths.

    DOT National Transportation Integrated Search

    2014-02-01

    In 1994 the Michigan Department of Transportation (MDOT) initiated a sewer and culvert : condition research conducted at various locations throughout Southeast and Southwest : Michigan to review the performance of concrete, plastic and metal pipe tha...

  15. NPDES Permit for Fort Carson Municipal Separate Storm Sewer System in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-R042001, Fort Carson is authorized to discharge from all municipal separate storm sewer system outfalls to receiving waters which include B-Ditch, Clover Ditch, Infantry Creek, Rock Creek, and others in El Paso County, Colorado.

  16. NPDES Permit for Denver VA Hospital Municipal Separate Storm Sewer System in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-R042008, the Veterans Administration (Medical Center, Denver Campus) is authorized to discharge from all municipal separate storm sewer system outfalls to the receiving waters specified in the permit in the City of Denver, Colorado.

  17. STREET SURFACE STORAGE FOR CONTROL OF COMBINED SEWER SURCHARGE

    EPA Science Inventory

    One type of Best Management Practices (BMPs) available is the use of street storage systems to prevent combined sewer surcharging and to mitigate basement flooding. A case study approach, based primarily on two largely implemented street storage systems, will be used to explain ...

  18. A microcomputer model for simulating pressurized flow in a storm sewer system : interim report.

    DOT National Transportation Integrated Search

    1988-01-01

    A study is being conducted on the development of a microcomputer model for simulating storm sewer flow under surcharged or pressurized conditions. Several existing models, including the EPA Storm Water Management Hodel (SYMM) and the Illinois Urban D...

  19. Effects of sanitary sewers on ground-water levels and streams in Nassau and Suffolk Counties, New York; Part 3, development and application of southern Nassau County model

    USGS Publications Warehouse

    Reilly, T.E.; Buxton, H.T.

    1985-01-01

    By 1990, sanitary sewers in Nassau County Sewage Disposal Districts 2 and 3 and Suffolk County Southwest Sewer District will discharge to the ocean 140 cu ft of water per second that would otherwise be returned to the groundwater system through septic tanks and similar systems. To evaluate the effects of this loss on groundwater levels and streamflow, the U.S. Geological Survey developed a groundwater flow model that couples a fine-scale subregional model to a regional model of a larger scale. The regional model generates flux boundary conditions for the subregional model, and the subregional model provides detail in the area of concern. Results indicate that the water table will decline by as much as 90% from conditions in the early 1970's. This report is one of a three-part series describing the predicted hydrologic effects of sewers in southern Nassau and southwestern Suffolk Counties. (USGS)

  20. Measurement of infiltration rates in urban sewer systems by use of oxygen isotopes.

    PubMed

    De Bénédittis, J; Bertrand-Krajewski, J L

    2005-01-01

    The paper presents the principle of a method to measure infiltration rates in sewer systems based on the use of oxygen isotopes and its application in Lyon (France). In the urban area of Lyon, significant differences in delta 18O that can reach 3 per thousand are observed between the oxygen isotopic compositions of groundwater originating from Rhone, Saone and from their associated alluvial aquifers. Drinking water supplying Lyon results mainly from pumping in the Rhone alluvial aquifer. Therefore, in some areas, the difference of isotopic composition between wastewater resulting from the consumption of drinking water and local groundwater can be used to measure infiltration in sewer systems. The application in the catchment of Ecully shows that the infiltration flow rate presents strong fluctuations at an hourly scale: it varies between 15 and 40 m3/h. This variability could be explained by non-constant discharges of pumping and by variations of the water level in the sewer.

  1. Coordinated management of combined sewer overflows by means of environmental decision support systems.

    PubMed

    Murla, Damian; Gutierrez, Oriol; Martinez, Montse; Suñer, David; Malgrat, Pere; Poch, Manel

    2016-04-15

    During heavy rainfall, the capacity of sewer systems and wastewater treatment plants may be surcharged producing uncontrolled wastewater discharges and a depletion of the environmental quality. Therefore there is a need of advanced management tools to tackle with these complex problems. In this paper an environmental decision support system (EDSS), based on the integration of mathematical modeling and knowledge-based systems, has been developed for the coordinated management of urban wastewater systems (UWS) to control and minimize uncontrolled wastewater spills. Effectiveness of the EDSS has been tested in a specially designed virtual UWS, including two sewers systems, two WWTP and one river subjected to typical Mediterranean rain conditions. Results show that sewer systems, retention tanks and wastewater treatment plants improve their performance under wet weather conditions and that EDSS can be very effective tools to improve the management and prevent the system from possible uncontrolled wastewater discharges. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Combined sewer overflows to surface waters detected by the anthropogenic marker caffeine.

    PubMed

    Buerge, Ignaz J; Poiger, Thomas; Müller, Markus D; Buser, Hans-Rudolf

    2006-07-01

    Continuous progress in wastewater treatment technology and the growing number of households connected to wastewater treatment plants (WWTPs) have generally resulted in decreased environmental loading of many pollutants. Nonetheless, further reduction of pollutant inputs is required to improve the quality of surface waters in densely populated areas. In this context, the relative contribution of combined sewer overflows as sources of wastewater-derived contaminants has attracted more and more attention, but the quantitative importance of these overflows has barely been investigated. In this study, caffeine was successfully used as a chemical marker to estimate the fraction of sewer overflows in the catchment area of lake Greifensee, Switzerland. Caffeine is a ubiquitous compound in raw, domestic wastewater with typical per capita loads of approximately 16 mg person(-1) d(-1). In WWTPs of the Greifensee region, caffeine is largely eliminated (>99%), resulting in much smaller loads of < or = 0.15 mg person(-1) d(-1) in treated wastewater. However, in receiving streams as in the inflows to Greifensee, caffeine loads (0.1-1.6 mg person(-1) d(-1)) were higher than those in WWTP effluents, indicating additional sources. As the loads in the streams correlated with precipitation during sampling, it was concluded that combined sewer overflows were the most likely source of caffeine. Using a mass balance approach, it was possible to determine the fraction of wastewater (in dry weather equivalents) discharged untreated to the receiving streams (up to 10%, annual mean, approximately 2-3%). The concept of caffeine as a marker for combined sewer overflows was then applied to estimate phosphorus inputs to Greifensee with untreated and treated wastewater (approximately 1.5 and 2.0 t P y(-1), respectively), which corresponded well with P inputs determined in a separate study based on hydraulic considerations. For compounds with high elimination in WWTPs such as phosphorus (96-98% in the Greifensee area), inputs from combined sewer overflows are thus of similar magnitude as inputs from treated wastewater. The study demonstrated that caffeine is a suitable marker for untreated wastewater (from combined sewer overflows, direct discharges, etc.), but its sensitivity depends on regional conditions and decreases with decreasing elimination efficiency in WWTPs.

  3. Sensor Agent Processing Software (SAPS)

    DTIC Science & Technology

    2004-05-01

    buildings, sewers, and tunnels. The time scale governs many aspects of tactical sensing. In high intensity combat situations forces move within...21 Figure 9-2 BAE Systems Sitex00 High Bandwidth...float) Subscribers Subscribers Preprocessor Channel 1 xout[256] Data File in Memory xout[256] S w i t c h High Pass Filter (IIR) xin[256] xout[256

  4. Dynamic online sewer modelling in Helsingborg.

    PubMed

    Hernebring, C; Jönsson, L E; Thorén, U B; Møller, A

    2002-01-01

    Within the last decade, the sewer system in Helsingborg, Sweden has been rehabilitated in many ways along with the reconstruction of the WWTP Oresundsverket in order to obtain a high degree of nitrogen and phosphorus removal. In that context a holistic view has been applied in order to optimise the corrective measures as seen from the effects in the receiving waters. A sewer catchment model has been used to evaluate several operation strategies and the effect of introducing RTC. Recently, a MOUSE ONLINE system was installed. In this phase the objective is to establish a stable communication with the SCADA system and to generate short-term flow forecasts.

  5. Transient Point Infiltration In The Unsaturated Zone

    NASA Astrophysics Data System (ADS)

    Buecker-Gittel, M.; Mohrlok, U.

    The risk assessment of leaking sewer pipes gets more and more important due to urban groundwater management and environmental as well as health safety. This requires the quantification and balancing of transport and transformation processes based on the water flow in the unsaturated zone. The water flow from a single sewer leakage could be described as a point infiltration with time varying hydraulic conditions externally and internally. External variations are caused by the discharge in the sewer pipe as well as the state of the leakage itself. Internal variations are the results of microbiological clogging effects associated with the transformation processes. Technical as well as small scale laboratory experiments were conducted in order to investigate the water transport from an transient point infiltration. From the technical scale experiment there was evidence that the water flow takes place under transient conditions when sewage infiltrates into an unsaturated soil. Whereas the small scale experiments investigated the hydraulics of the water transport and the associated so- lute and particle transport in unsaturated soils in detail. The small scale experiment was a two-dimensional representation of such a point infiltration source where the distributed water transport could be measured by several tensiometers in the soil as well as by a selective measurement of the discharge at the bottom of the experimental setup. Several series of experiments were conducted varying the boundary and initial con- ditions in order to derive the important parameters controlling the infiltration of pure water from the point source. The results showed that there is a significant difference between the infiltration rate in the point source and the discharge rate at the bottom, that could be explained by storage processes due to an outflow resistance at the bottom. This effect is overlayn by a decreasing water content decreases over time correlated with a decreasing infiltration rate. As expected the initial conditions mainly affects the time scale for the water transport. Additionally, the influence of preferential flow paths on the discharge distribution could be found due to the heterogenieties caused by the filling and compaction process of the sandy soil.

  6. SSOAP - A USEPA TOOLBOX FOR SSO ANALYSIS AND CONTROL PLANNING

    EPA Science Inventory

    Rainfall Derived Infiltration and Inflow (RDII) into sanitary sewer systems has long been recognized as a source of operating problems in sewerage systems. RDII is the main cause of sanitary sewer overflows (SSOs) to basements, streets, or nearby streams and can also cause seriou...

  7. 40 CFR 35.927 - Sewer system evaluation and rehabilitation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... excessive infiltration/inflow. A determination of whether excessive infiltration/inflow exists may take into... excessive infiltration/inflow exists. It will consist of: (1) Certification by the State agency, as appropriate; and, when necessary, (2) An infiltration/inflow analysis; and, if appropriate, (3) A sewer system...

  8. 40 CFR 35.927 - Sewer system evaluation and rehabilitation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... excessive infiltration/inflow. A determination of whether excessive infiltration/inflow exists may take into... excessive infiltration/inflow exists. It will consist of: (1) Certification by the State agency, as appropriate; and, when necessary, (2) An infiltration/inflow analysis; and, if appropriate, (3) A sewer system...

  9. 40 CFR 35.927 - Sewer system evaluation and rehabilitation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... excessive infiltration/inflow. A determination of whether excessive infiltration/inflow exists may take into... excessive infiltration/inflow exists. It will consist of: (1) Certification by the State agency, as appropriate; and, when necessary, (2) An infiltration/inflow analysis; and, if appropriate, (3) A sewer system...

  10. 40 CFR 35.927 - Sewer system evaluation and rehabilitation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... excessive infiltration/inflow. A determination of whether excessive infiltration/inflow exists may take into... excessive infiltration/inflow exists. It will consist of: (1) Certification by the State agency, as appropriate; and, when necessary, (2) An infiltration/inflow analysis; and, if appropriate, (3) A sewer system...

  11. 40 CFR 35.927 - Sewer system evaluation and rehabilitation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... excessive infiltration/inflow. A determination of whether excessive infiltration/inflow exists may take into... excessive infiltration/inflow exists. It will consist of: (1) Certification by the State agency, as appropriate; and, when necessary, (2) An infiltration/inflow analysis; and, if appropriate, (3) A sewer system...

  12. Association between Gastrointestinal Illness and Precipitation in Areas Impacted by Combined Sewer Facilities: Analysis of Massachusetts Data, 2003-2007

    EPA Science Inventory

    Background: Combined sewer systems (CSS) collect rainwater runoff, sewage, and industrial wastewater for transit to treatment facilities. With heavy precipitation, volumes can exceed capacity of treatment facilities, and wastewater discharges directly to receiving waters. These c...

  13. REDUCED COST SEWER PIPE RELINING USING ULTRASONIC TAPE LAMINATION - PHASE II

    EPA Science Inventory

    During the Phase I program, Foster-Miller developed techniques based on Ultrasonic Tape Lamination (UTL) for joining of plasticized PVC sewer pipe liner. This effort was undertaken in response to a need for environmentally sound and cost-effective methods for rehabilitation of...

  14. USEPA PAST AND PLANNED RESEARCH ON CONTROL OF INFILTRATION/INFLOW

    EPA Science Inventory

    From the mid 1960s-1980s, the USEPA conducted a series of research, development and demonstration projects on the characterization, cause and consequence, and control of infiltartion/inflow (I/I) in sanitary sewers under the Storm and Combined Sewer pollution Control Research pro...

  15. NPDES Permit for NIST Boulder Laboratories Municipal Separate Storm Sewer System in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-R042002,NIST is authorized to discharge from all municipal separate storm sewer outfalls existing as of the effective date of this permit to receiving waters within the exterior boundaries of the Boulder Laboratories in Boulder, Colo.

  16. A microcomputer model for simulating pressurized flow in a storm sewer system : final report.

    DOT National Transportation Integrated Search

    1989-01-01

    A review was made of several computer programs capable of simulating sewer flows under surcharge or pressurized flow conditions. A modified version of the EXTRAN module of the SYMM model, called PFSM, was developed and attached to the FHYA Pooled Fun...

  17. NPDES Permit for Peterson Air Force Base Municipal Separate Storm Sewer System in Colorado

    EPA Pesticide Factsheets

    NPDES permit CO-R042006, authorizes Peterson AFB to discharge from all municipal separate storm sewer system outfalls to receiving waters which include the East Fork of Sand Creek and others within exterior AFB boundaries in El Paso County, Colorado.

  18. Quantifying fat, oil, and grease deposit formation kinetics

    USDA-ARS?s Scientific Manuscript database

    Fat, oil, and grease (FOG) deposits formed in sanitary sewers are calcium-based saponified solids that are responsible for a significant number of nationwide sanitary sewer overflows (SSOs) across United States. In the current study, the kinetics of lab-based saponified solids were determined to un...

  19. 40 CFR 35.2208 - Adoption of sewer use ordinance and user charge system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... works is placed in operation. Further, the grantee shall implement the user charge system and sewer use ordinance for the useful life of the treatment works. ... GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works...

  20. Transfer of glyphosate and its degradate AMPA to surface waters through urban sewerage systems.

    PubMed

    Botta, Fabrizio; Lavison, Gwenaëlle; Couturier, Guillaume; Alliot, Fabrice; Moreau-Guigon, Elodie; Fauchon, Nils; Guery, Bénédicte; Chevreuil, Marc; Blanchoud, Hélène

    2009-09-01

    A study of glyphosate and aminomethyl phosphonic acid (AMPA) transfer in the Orge watershed (France) was carried out during 2007 and 2008. Water samples were collected in surface water, wastewater sewer, storm sewer and wastewater treatment plant (WWTP). These two molecules appeared to be the most frequently detected ones in the rivers and usually exceeded the European quality standard concentrations of 0.1microg L(-1) for drinking water. The annual glyphosate estimated load was 1.9 kg year(-1) upstream (agricultural zone) and 179.5 kg year(-1) at the catchment outlet (urban zone). This result suggests that the contamination of this basin by glyphosate is essentially from urban origin (road and railway applications). Glyphosate reached surface water prevalently through storm sewer during rainfall event. Maximum concentrations were detected in storm sewer just after a rainfall event (75-90 microg L(-1)). High concentrations of glyphosate in surface water during rainfall events reflected urban runoff impact. AMPA was always detected in the sewerage system. This molecule reached surface water mainly via WWTP effluent and also through storm sewer. Variations in concentrations of AMPA during hydrological episodes were minor compared to glyphosate variations. Our study highlights that AMPA and glyphosate origins in urban area are different. During dry period, detergent degradation seemed to be the major AMPA source in wastewater.

  1. Identification of sewer pipes to be cleaned for reduction of CSO pollutant load.

    PubMed

    Nagaiwa, Akihiro; Settsu, Katsushi; Nakajima, Fumiyuki; Furumai, Hiroaki

    2007-01-01

    To reduce the CSO (Combined Sewer Overflow) pollutant discharge, one of the effective options is cleaning of sewer pipes before rainfall events. To maximize the efficiency, identification of pipes to be cleaned is necessary. In this study, we discussed the location of pipe deposit in dry weather in a combined sewer system using a distributed model and investigated the effect of pipe cleaning to reduce the pollutant load from the CSO. First we simulated the dry weather flow in a combined sewer system. The pipe deposit distribution in the network was estimated after 3 days of dry weather period. Several specific pipes with structural defect and upper end pipes tend to have an accumulation of deposit. Wet weather simulations were conducted with and without pipe cleaning in rainfall events with different patterns. The SS loads in CSO with and without the pipe cleaning were compared. The difference in the estimated loads was interpreted as the contribution of wash-off in the cleaned pipe. The effect of pipe cleaning on reduction of the CSO pollutant load was quantitatively evaluated (e.g. the cleaning of one specific pipe could reduce 22% of total CSO load). The CSO simulations containing pipe cleaning options revealed that identification of pipes with accumulated deposit using the distributed model is very useful and informative to evaluate the applicability of pipe cleaning option for CSO pollutant reduction.

  2. Implication of climate change on urban drainage systems of Chicago and Mainstream and DesPlaines (MS/DP) Tunnel and Reservoir Plan (TARP)

    NASA Astrophysics Data System (ADS)

    Luo, H.; Schmidt, A.; Garcia, M. H.; Oberg, N.

    2016-12-01

    The impact of changing climate patterns and rainfall extremes on sewer system and river basin has been brought to attention to the researchers worldwide. In 1972, the Metropolitan Water Reclamation District of Greater Chicago (MWRDGC) adopted the Tunnel and Reservoir Plan (TARP) to address combined sewer overflow (CSO) pollution and flooding problems in the Chicago land area. The hydrosystem laboratory in University of Illinois at Urbana-Champaign developed a series of numerical models accordingly to analyze the complex hydraulic behavior of the as-built TARP system. Due to the interconnected nature of City of Chicago sewer network and MS/DP TARP system, a tightly coupled hydrological and hydraulic model MetroFlow was developed to facilitate such analysis by integrating previous developed models. This study utilized MetroFlow to predict the hydrologic/hydraulic response of the system for a set of pre-determined design and historical storm events. Accordingly, combined sewer overflows (CSO) of Chicago combined sewer system and MS/DP TARP system were evaluated under current and future weather scenarios. The total CSOs from TARP system can be considered as urban point pollution source to the surrounding receiving bodies, hence the potential impact of climate change on CSO fluxes is essential reference to wastewater infrastructure design and operations of the hydraulic regulating structures under storm events to mitigate predicted risks.

  3. Optimise inlet condition and design parameters of a new sewer overflow screening device using numerical model.

    PubMed

    Aziz, M A; Imteaz, M A; Huda, Nazmul; Naser, J

    2014-01-01

    After heavy rainfall, sewer overflow spills to receiving water bodies cause serious concern for the environment, aesthetics and public health. To overcome these problems this study investigated a new self-cleansing sewer overflow screening device. The device has a sewer overflow chamber, a rectangular tank and a slotted ogee weir to capture the gross pollutants. To design an efficient screening device a numerical computational fluid dynamic (CFD) model was used. A plausibility check of the CFD model was done using a one-dimensional analytical model. Results showed that an inlet parallel to the weir ensured better self-cleansing than an inlet perpendicular to the weir. Perforations should be at the bottom of the weir to get increased velocity and shear stress to create a favourable self-cleaning effect of the screening device. Increasing inlet length from 0.3 to 1.5 m reduced wave reflection up to 10%, which increased flow uniformity downstream and improved self-cleansing effect. The orientation of the ogee weir with the rectangular tank was found most uniform with a 1:3 (horizontal:vertical) slope. These results will help to maximise functional efficiency of the new sewer overflow screening device. Otherwise it would be too expensive to alter after installation and at times difficult to customise accordingly to existing urban drainage systems.

  4. Effects of pH, Temperature, Dissolved Oxygen, and Flow Rate on Phosphorus Release Processes at the Sediment and Water Interface in Storm Sewer

    PubMed Central

    Li, Haiyan; Li, Mingyi; Zhang, Xiaoran

    2013-01-01

    The effects of pH, temperature, dissolved oxygen (DO), and flow rate on the phosphorus (P) release processes at the sediment and water interface in rainwater pipes were investigated. The sampling was conducted in a residential storm sewer of North Li Shi Road in Xi Cheng District of Beijing on August 3, 2011. The release rate of P increased with the increase of pH from 8 to 10. High temperature is favorable for the release of P. The concentration of total phosphorus (TP) in the overlying water increased as the concentration of DO decreased. With the increase of flow rate from 0.7 m s−1 to 1.1 m s−1, the concentration of TP in the overlying water increased and then tends to be stable. Among all the factors examined in the present study, the flow rate is the primary influence factor on P release. The cumulative amount of P release increased with the process of pipeline runoff in the rainfall events with high intensities and shorter durations. Feasible measures such as best management practices and low-impact development can be conducted to control the P release on urban sediments by slowing down the flow rate. PMID:24349823

  5. COLLECTION SYSTEM SOLIDS CONTROL: OVERVIEW OF AN EPA WET-WEATHER FLOW RESEARCH PROGRAM

    EPA Science Inventory

    This paper presents an historical overview of the sewer-solids control projects conducted by the Wet-Weather Flow Research Program of the US EPA. Research includes studies of the causes of sewer-solids deposition and development/evaluation of control methods that can prevent sewe...

  6. Sewer Lateral Electro Scan Field Verification Pilot (WERF Report INFR4R12)

    EPA Science Inventory

    Abstract:WERF selected a proposed research project to field test an emerging technology for inspecting sanitary sewer lateral pipes. The technology is called Electro Scan and is used to find defects in laterals that allow the infiltration of groundwater into the lateral. Electro ...

  7. 40 CFR 35.2024 - Combined sewer overflows.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... project priority list, it addresses impaired uses in priority water quality areas which are due to the... must demonstrate to the Administrator that the water quality goals of the Act will not be achieved... priority water quality areas in marine bays and estuaries due to the impacts of combined sewer overflows...

  8. Effects of climate and sewer condition on virus transport to groundwater

    USDA-ARS?s Scientific Manuscript database

    Pathogen contamination from leaky sanitary sewers poses a threat to groundwater quality in urban areas, yet the spatial and temporal dimensions of this contamination are not well understood. In this study, 16 monitoring wells and six municipal wells were repeatedly sampled for human enteric viruses....

  9. 18 CFR 430.13 - Protected area permits for new withdrawals.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... approved by the Commission. (3) A program to monitor and control ground water infiltration to the receiving sewer system. The program must quantify ground water infiltration to the system and document reductions in infiltration. The program should include such measures as leakage surveys of sewer mains, metering...

  10. 18 CFR 430.13 - Protected area permits for new withdrawals.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... approved by the Commission. (3) A program to monitor and control ground water infiltration to the receiving sewer system. The program must quantify ground water infiltration to the system and document reductions in infiltration. The program should include such measures as leakage surveys of sewer mains, metering...

  11. 18 CFR 430.13 - Protected area permits for new withdrawals.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... approved by the Commission. (3) A program to monitor and control ground water infiltration to the receiving sewer system. The program must quantify ground water infiltration to the system and document reductions in infiltration. The program should include such measures as leakage surveys of sewer mains, metering...

  12. 18 CFR 430.13 - Protected area permits for new withdrawals.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... approved by the Commission. (3) A program to monitor and control ground water infiltration to the receiving sewer system. The program must quantify ground water infiltration to the system and document reductions in infiltration. The program should include such measures as leakage surveys of sewer mains, metering...

  13. Report: American Recovery and Reinvestment Act Site Visit of the Clifton Street Sewer Separation and Water Main Replacement Projects, Portland, Maine

    EPA Pesticide Factsheets

    Report #11-R-0248, June 7, 2011. We conducted an unannounced site visit of the Clifton Street Sewer Separation and Water Main Replacement Projects in the City of Portland, Maine, from June 15 through June 17, 2009.

  14. Report: Unallowable Federal Funds Drawn on EPA Grant No. XP98247201 Awarded to the Wayne County Water and Sewer Authority, New York

    EPA Pesticide Factsheets

    Report #08-2-0045, December 17, 2007. The Wayne County Water and Sewer Authority (grantee) claimed and was reimbursed for preaward costs of $276,268 that are unallowable under Federal regulations and the grant terms and conditions.

  15. Measuring Flow Reductions in a Combined Sewer System Using Green Infrastructure

    EPA Science Inventory

    A green infrastructure (GI) design approach was used in CSO Basin #130, a 17-acre sewershed in the Butchertown section of Louisville, Kentucky, to reduce combined sewer overflows (CSOs). For the design year, the modeled design was expected to reduce the CSO frequency from 34 to ...

  16. COMPUTER MODEL ANALYSIS FOR MITIGATION PLANNING OF SANITARY-SEWER OVERFLOWS

    EPA Science Inventory

    Sanitary sewer overflows (SSOs) are generally difficult to witness or document as they usually occur during rain events when people are indoors or out of sight. To anser where and when an SSO may occur, it is necessary to know the flow conveyance capacity at various parts of the ...

  17. Automatic Vacuum Flushing Technology for Combined Sewer Solids: Laboratory Testing and Proposed Improvements (WERF Report INFR7SG09)

    EPA Science Inventory

    This research study included an extensive literature review on existing sewer sediment flushing technologies. An innovative vacuum flush system previously developed by the U.S. EPA was tested under laboratory conditions. The tests revealed a strong correlation between the strengt...

  18. Green Infrastructure in the Mix to Reduce District of Columbia Sewer Overflows

    EPA Pesticide Factsheets

    District of Columbia's Long Term Control Plan to keep sewage out of the city’s rivers is being modified to include a substantial greening component for the first time, making it a dominant feature of 2 of the 3 drainage areas of the combined sewer system.

  19. AN ASSESSMENT OF AUTOMATIC SEWER FLOW SAMPLERS (EPA/600/2-75/065)

    EPA Science Inventory

    A brief review of the characteristics of storm and combined sewer flows is given followed by a general discussion of the purposes for and requirements of a sampling program. The desirable characteristics of automatic sampling equipment are set forth and problem areas are outlined...

  20. Demonstration of Green/Gray Infrastructure for Combined Sewer Overflow Control

    EPA Science Inventory

    This project is a major national demonstration of the integration of green and gray infrastructure for combined sewer overflow (CSO) control in a cost-effective and environmentally friendly manner. It will use Kansas City, MO, as a case example. The project will have a major in...

  1. STORM AND COMBINED SEWER OVERFLOW: AN OVERVIEW OF EPA'S RESEARCH PROGRAM (EPA/600/8-89/054)

    EPA Science Inventory

    This report represents an overview of the EPA's Storm & Combined Sewer Pollution Control Research Program performed over a 20-year period beginning with the mid-1960s. It covers program involvements in the development of a diverse technology including pollution-problem assessment...

  2. Sanitary Sewer Overflows and Association with Gastrointestinal Illness: A case crossover analysis of Massachusetts Data, 2006-2007

    EPA Science Inventory

    Sanitary sewer overflows (SSOs) occur when untreated sewage is discharged into water sources potentially causing contamination. SSOs are primarily caused by heavy rainfall, which is expected to become heavier and more episodic due to climate change. We conducted a case-crossover ...

  3. RATES OF GASTROINTESTINAL ILLNESS AMONG AREAS IMPACTED BY COMBINED SEWER FACILITIES: ANALYSIS OF MASSACHUSETTS DATA, 2003-2007

    EPA Science Inventory

    Previous studies have reported a temporal association between heavy rainfall and gastrointestinal infection (GI). Combined sewer systems (CSSs), which are present in many urban areas in the US, were designed to collect rainwater runoff, domestic sewage, and industrial wastewater ...

  4. 40 CFR 35.2024 - Combined sewer overflows.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2024 Combined sewer... project priority list, it addresses impaired uses in priority water quality areas which are due to the... must demonstrate to the Administrator that the water quality goals of the Act will not be achieved...

  5. 40 CFR 35.2024 - Combined sewer overflows.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2024 Combined sewer... project priority list, it addresses impaired uses in priority water quality areas which are due to the... must demonstrate to the Administrator that the water quality goals of the Act will not be achieved...

  6. 40 CFR 35.2024 - Combined sewer overflows.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2024 Combined sewer... project priority list, it addresses impaired uses in priority water quality areas which are due to the... must demonstrate to the Administrator that the water quality goals of the Act will not be achieved...

  7. Water quality in the Mahoning River and selected tributaries in Youngstown, Ohio

    USGS Publications Warehouse

    Stoeckel, Donald M.; Covert, S. Alex

    2002-01-01

    The lower reaches of the Mahoning River in Youngstown, Ohio, have been characterized by the Ohio Environmental Protection Agency (OEPA) as historically having poor water quality. Most wastewater-treatment plants (WWTPs) in the watershed did not provide secondary sewage treatment until the late 1980s. By the late 1990s, the Mahoning River still received sewer-overflow discharges from 101 locations within the city of Youngstown, Ohio. The Mahoning River in Youngstown and Mill Creek, a principal tributary to the Mahoning River in Youngstown, have not met biotic index criteria since the earliest published assessment by OEPA in 1980. Youngstown and the OEPA are working together toward the goal of meeting water-quality standards in the Mahoning River. The U.S. Geological Survey collected information to help both parties assess water quality in the area of Youngstown and to estimate bacteria and inorganic nitrogen contributions from sewer-overflow discharges to the Mahoning River. Two monitoring networks were established in the lower Mahoning River: the first to evaluate hydrology and microbiological and chemical water quality and the second to assess indices of fish and aquatic-macroinvertebrate-community health. Water samples and water-quality data were collected from May through October 1999 and 2000 to evaluate where, when, and for how long water quality was affected by sewer-overflow discharges. Water samples were collected during dry- and wet-weather flow, and biotic indices were assessed during the first year (1999). The second year of sample collection (2000) was directed toward evaluating changes in water quality during wet-weather flow, and specifically toward assessing the effect of sewer-overflow discharges on water quality in the monitoring network. Water-quality standards for Escherichia coli (E. coli) concentration and draft criteria for nitrate plus nitrite and total phosphorus were the regulations most commonly exceeded in the Mahoning River and Mill Creek sampling networks. E. coli concentrations increased during wet-weather flow and remained higher than dry-weather concentrations for 48 hours after peak flow. E. coli concentration criteria were more commonly exceeded during wet-weather flow than during dry-weather flow. Exceedances of nutrient-concentration criteria were not substantially more common during wet-weather flow. The fish and aquatic macroinvertebrate network included Mill Creek and its tributaries but did not include the main stem of the Mahoning River. Persistent exceedances of chemical water-quality standards in Mill Creek and the presence of nutrient concentrations in excess of draft criteria may have contributed to biotic index scores that on only one occasion met State criteria throughout the fish and aquatic macroinvertebrate sampling network. Monitored tributary streams did not contribute concentrations of E. coli, nitrate plus nitrite, or total phosphorus to the Mahoning River and Mill Creek that were higher than main-stem concentrations, but monitored WWTP and sewer-overflow discharges did contribute. Twenty-four hour load estimates of sewer-overflow discharge contributions during wet-weather flow indicated that sewer-overflow discharges contributed large loads of bacteria and inorganic nitrogen to the Mahoning River relative to the instream load. The sewer-overflow loads appeared to move as a slug of highly enriched water that passed through Youngstown on the rising limb of the storm hydrograph. The median estimated sewer-overflow load contribution of bacteria was greater than the estimated instream load by a factor of five or more; however, the median estimated sewer-overflow load of inorganic nitrogen was less than half of the estimated instream load. Sewer-overflow discharges contributed loads of E. coli and nutrients to the Mahoning River and Mill Creek at a point where the streams already did not meet State water-quality regulations. Improvement of water quality of

  8. Distributed simulation of long-term hydrological processes in a medium-sized periurban catchment under changing land use and rainwater management.

    NASA Astrophysics Data System (ADS)

    Labbas, Mériem; Braud, Isabelle; Branger, Flora; Kralisch, Sven

    2013-04-01

    Growing urbanization and related anthropogenic processes have a high potential to influence hydrological process dynamics. Typical consequences are an increase of surface imperviousness and modifications of water flow paths due to artificial channels and barriers (combined and separated system, sewer overflow device, roads, ditches, etc.). Periurban catchments, at the edge of large cities, are especially affected by fast anthropogenic modifications. They usually consist of a combination of natural areas, rural areas with dispersed settlements and urban areas mostly covered by built zones and spots of natural surfaces. In the context of the European Water Framework Directive (2000) and the Floods Directive (2007), integrated and sustainable solutions are needed to reduce flooding risks and river pollution at the scale of urban conglomerations or whole catchments. Their thorough management requires models able to assess the vulnerability of the territory and to compare the impact of different rainwater management options and planning issues. To address this question, we propose a methodology based on a multi-scale distributed hydrological modelling approach. It aims at quantifying the impact of ongoing urbanization and stormwater management on the long-term hydrological cycle in medium-sized periurban watershed. This method focuses on the understanding and formalization of dominant periurban hydrological processes from small scales (few ha to few km2) to larger scales (few hundred km2). The main objectives are to 1) simulate both urban and rural hydrological processes and 2) test the effects of different long-term land use and water management scenarios. The method relies on several tools and data: a distributed hydrological model adapted to the characteristics of periurban areas, land use and land cover maps from different dates (past, present, future) and information about rainwater management collected from local authorities. For the application of the method, the medium-scaled catchment of Yzeron (France) is chosen. It is subjected to a fast progression of urbanization since the eighties and has been monitored for a long time period. The fully-distributed hydrological model J2000, available through the JAMS modelling framework, was found appropriate to simulate the water balance of the Yzeron catchment at a daily time step. However, it was not designed especially for periurban areas, so its structure and parameters are under adaptation. Firstly, as hydrological responses in urban areas are quicker than in rural areas, a sub-daily time step is necessary to improve the simulation of periurban hydrological processes. Therefore, J2000 was adapted to be run at a hourly time step. Secondly, in order to better take into account rainwater management, an explicit representation of sewer networks is implemented in the J2000 model whose periurban version is called J2000P. It receives urban rainwater coming from impervious surfaces connected to a combined sewer system and delivers this water to the treatment plant or directly to the river in case of sewer overflow device outflows. We will present the impact of these modifications on the simulated hydrological regime.

  9. Stormwater quality modelling in combined sewers: calibration and uncertainty analysis.

    PubMed

    Kanso, A; Chebbo, G; Tassin, B

    2005-01-01

    Estimating the level of uncertainty in urban stormwater quality models is vital for their utilization. This paper presents the results of application of a Monte Carlo Markov Chain method based on the Bayesian theory for the calibration and uncertainty analysis of a storm water quality model commonly used in available software. The tested model uses a hydrologic/hydrodynamic scheme to estimate the accumulation, the erosion and the transport of pollutants on surfaces and in sewers. It was calibrated for four different initial conditions of in-sewer deposits. Calibration results showed large variability in the model's responses in function of the initial conditions. They demonstrated that the model's predictive capacity is very low.

  10. Guidelines For Utilizing Rain Gardens as a Stormwater Management Tool in the Metropolitan Sewer District of Greater Cincinnati (MSD) - Steps to Getting off of the Storwater "Grid"

    EPA Science Inventory

    Rain gardens are designed to capture and infiltrate rainwater in the landscape. These gardens are also called "rain water gardens". Rainwater is routed to the garden and filtered naturally by the plants and soils in the garden. This filtration process removes nutrients and poll...

  11. REMOVAL OF TANK AND SEWER SEDIMENT BY GATE FLUSHING: COMPUTATIONAL FLUID DYNAMICS MODEL STUDIES

    EPA Science Inventory

    This presentation will discuss the application of a computational fluid dynamics 3D flow model to simulate gate flushing for removing tank/sewer sediments. The physical model of the flushing device was a tank fabricated and installed at the head-end of a hydraulic flume. The fl...

  12. THE CHOICE OF REAL-TIME CONTROL STRATEGY FOR COMBINED SEWER OVERFLOW CONTROL

    EPA Science Inventory

    This paper focuses on the strategies used to operate a collection system in real-time control (RTC) in order to optimize use of system capacity and to reduce the cost of long-term combined sewer overflow (CSO) control. Three RTC strategies were developed and analyzed based on the...

  13. Interim Significant Noncompliance Policy for Clean Water Act Violations Associated with CSOs, SSOs, CAFOs, and Storm Water Point Sources

    EPA Pesticide Factsheets

    This policy addresses significant noncompliance (SNC) violations associated with combined sewer overflows (CSOs), sanitary sewer overflows (SSOs), concentrated animal feeding operations (CAFOs), and storm water point source discharges covered by the National Pollutant Discharge Elimination System (NPDES) program under the Clean Water Act (CWA).

  14. Evaluation of Green Alternatives for Combined Sewer Overflow Mitigation: A Proposed Economic Impact Framework and Illustration of its Application

    EPA Science Inventory

    This report develops a broad framework, or taxonomy, for identifying and organizing the socio-economic impacts of sewer infrastructure projects. It focuses on a green project in Cincinnati, Ohio that has adopted broader economic goals. The report then uses this example to illustr...

  15. 78 FR 5185 - Notice of Availability of Final Environmental Assessment (FINAL EA) and a Finding of No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-24

    ... Metropolitan Sewer District of Greater Cincinnati Easement on HHS/CDC/NIOSH Taft North Campus, Cincinnati, OH AGENCY: Centers for Disease Control and Prevention (CDC), Department of Health and Human Services (HHS... Significant Impact (FONSI) for Metropolitan Sewer District of Greater Cincinnati Easement on HHS/CDC/NIOSH...

  16. 33 CFR 238.7 - Decision criteria for participation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... upstream of the precise point where Federal flood control authorities become applicable. (b) Storm sewer... will be considered to be a part of local storm drainage to be addressed as part of the consideration of an adequate storm sewer system. The purpose of this system is to collect and convey to a natural...

  17. 33 CFR 238.7 - Decision criteria for participation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... upstream of the precise point where Federal flood control authorities become applicable. (b) Storm sewer... will be considered to be a part of local storm drainage to be addressed as part of the consideration of an adequate storm sewer system. The purpose of this system is to collect and convey to a natural...

  18. 33 CFR 238.7 - Decision criteria for participation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... upstream of the precise point where Federal flood control authorities become applicable. (b) Storm sewer... will be considered to be a part of local storm drainage to be addressed as part of the consideration of an adequate storm sewer system. The purpose of this system is to collect and convey to a natural...

  19. 78 FR 25435 - Draft National Pollutant Discharge Elimination System (NPDES) General Permit for Municipal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-01

    ... (NPDES) General Permit for Municipal Separate Storm Sewer Systems in the Middle Rio Grande Watershed in... Elimination System (NPDES) general permit for storm water discharges from municipal separate storm sewer... issued for various categories of storm water discharges. Section 402(p)(2) requires permits for five...

  20. 31. RECORD PLAN, METROPOLITAN SEWER, GENERAL PLAN OF PUMPING STATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. RECORD PLAN, METROPOLITAN SEWER, GENERAL PLAN OF PUMPING STATION GROUNDS, DEER ISLAND. METROPOLITAN SEWERAGE COMMISSION, JUNE 1896. Photocopy of image of aperture card 4977-1. Aperture cards and original drawings at Massachusetts Water Resources Authority Archives, Building 39, Charlestown Navy Yard, Boston, MA - Deer Island Pumping Station, Boston, Suffolk County, MA

  1. 76 FR 35215 - Notice of EPA Workshop on Sanitary Sewer Overflows and Peak Wet Weather Discharges

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-16

    ... draft Peak Flows Policy. The workshop will include a facilitated discussion with representatives of organizations that represent POTWs, state NPDES permitting authorities, and non-for-profit environmental groups... maintained sanitary sewer systems are meant to collect and transport all of the sewage that flows into them...

  2. HIGH-RATE DISINFECTION OF COMBINED SEWER OVERFLOW USING CHLORINE DIOXIDE

    EPA Science Inventory

    This presentation is a state-of-the-art review of chlorine dioxide (ClO2) used for high-rate disinfection of combined sewer overflow (CSO). The review includes bench-, pilot-, and fullscale studies on the use of ClO2 as a disinfecting agent for a variety of wastewaters. Specific ...

  3. 76 FR 45617 - Notice of Lodging of the Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ...) violations stemming from its failure to properly operate and maintain its Combined Sewer Collection System..., implement approved operation and maintenance schedules of its sewers, conduct a pump station evaluation, as... from the Consent Decree Library, P.O. Box 7611, U.S. Department of Justice, Washington, DC 20044-7611...

  4. Assessment of spill flow emissions on the basis of measured precipitation and waste water data

    NASA Astrophysics Data System (ADS)

    Hochedlinger, Martin; Gruber, Günter; Kainz, Harald

    2005-09-01

    Combined sewer overflows (CSOs) are substantial contributors to the total emissions into surface water bodies. The emitted pollution results from dry-weather waste water loads, surface runoff pollution and from the remobilisation of sewer deposits and sewer slime during storm events. One possibility to estimate overflow loads is a calculation with load quantification models. Input data for these models are pollution concentrations, e.g. Total Chemical Oxygen Demand (COD tot), Total Suspended Solids (TSS) or Soluble Chemical Oxygen Demand (COD sol), rainfall series and flow measurements for model calibration and validation. It is important for the result of overflow loads to model with reliable input data, otherwise this inevitably leads to bad results. In this paper the correction of precipitation measurements and the sewer online-measurements are presented to satisfy the load quantification model requirements already described. The main focus is on tipping bucket gauge measurements and their corrections. The results evidence the importance of their corrections due the effects on load quantification modelling and show the difference between corrected and not corrected data of storm events with high rain intensities.

  5. DSM-flux: A new technology for reliable Combined Sewer Overflow discharge monitoring with low uncertainties.

    PubMed

    Maté Marín, Ainhoa; Rivière, Nicolas; Lipeme Kouyi, Gislain

    2018-06-01

    In the past ten years, governments from the European Union have been encouraged to collect volume and quality data for all the effluent overflows from separated stormwater and combined sewer systems that result in a significant environmental impact on receiving water bodies. Methods to monitor and control these flows require improvements, particularly for complex Combined Sewer Overflow (CSO) structures. The DSM-flux (Device for Stormwater and combined sewer flows Monitoring and the control of pollutant fluxes) is a new pre-designed and pre-calibrated channel that provides appropriate hydraulic conditions suitable for measurement of overflow rates and volumes by means of one water level gauge. In this paper, a stage-discharge relation for the DSM-flux is obtained experimentally and validated for multiple inflow hydraulic configurations. Uncertainties in CSO discharges and volumes are estimated within the Guide to the expression of Uncertainty in Measurement (GUM) framework. Whatever the upstream hydraulic conditions are, relative uncertainties are lower than 15% and 2% for the investigated discharges and volumes, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. The efficiency of asset management strategies to reduce urban flood risk.

    PubMed

    ten Veldhuis, J A E; Clemens, F H L R

    2011-01-01

    In this study, three asset management strategies were compared with respect to their efficiency to reduce flood risk. Data from call centres at two municipalities were used to quantify urban flood risks associated with three causes of urban flooding: gully pot blockage, sewer pipe blockage and sewer overloading. The efficiency of three flood reduction strategies was assessed based on their effect on the causes contributing to flood risk. The sensitivity of the results to uncertainty in the data source, citizens' calls, was analysed through incorporation of uncertainty ranges taken from customer complaint literature. Based on the available data it could be shown that increasing gully pot blockage is the most efficient action to reduce flood risk, given data uncertainty. If differences between cause incidences are large, as in the presented case study, call data are sufficient to decide how flood risk can be most efficiently reduced. According to the results of this analysis, enlargement of sewer pipes is not an efficient strategy to reduce flood risk, because flood risk associated with sewer overloading is small compared to other failure mechanisms.

  7. Efficacy of alpha-chlorhydrin in sewer rat control.

    PubMed Central

    Andrews, R. V.; Belknap, R. W.

    1983-01-01

    A single application of the male chemosterilant, alpha-chlorhydrin, to a problem sewer rat infestation resulted in reductions of rat numbers and distribution which was comparable to effects of warfarin baiting methods. Rat numbers were reduced by more than 85% by both methods. More rapid mortality and recruitment were evident for warfarin effects; the alpha-chlorhydrin treated population had a longer lag phase of growth so that reinfestation of sewer habitat to pre-treatment numbers, and distribution over a 40 square block area, required approximately 1.5-2 times longer after alpha-chlorhydrin treatment when compared with warfarin treatment. Comparisons of changes in rat densities in infested sewers following the two treatments indicate that recovery of warfarin treated populations is achieved by reproductive recruitment followed by dispersal while alpha-chlorhydrin treated populations recover by slower immigration and later reproductive recruitment. Alpha-chlorohydrin should be a useful addition to a limited arsenal of rat control agents because of its specificity for the Norway rat, its single dose effectiveness as a toxicant-chemosterilant, and its short environmental half-life. PMID:6644013

  8. Surface wastewater in Samara and their impact on water basins as water supply sources

    NASA Astrophysics Data System (ADS)

    Strelkov, Alexander; Shuvalov, Mikhail; Gridneva, Marina

    2017-10-01

    The paper gives an overview of surface wastewater outlets in Samara through the rainwater sewer system into the Saratov water reservoir and the Samara river. The rainwater sewer system in Samara is designed and executed according to a separate scheme, except for the old part of the city, where surface run-off is dumped into the sewer system through siphoned drain. The rainwater system disposes of surface, drainage, industrial clean-contamined waters, emergency and technology discharges from the city’s heat supply and water supply systems. The effluent discharge is carried out by means of separate wastewater outlets into ravines or directly into the Samara river and the Saratov water reservoir without cleaning. The effluent discharge is carried out through the rainwater sewer system with 17 wastewater outlets into the Saratov water reservoir. In the Samara river, surface runoff drainage and clean-contamined water of industrial enterprises is carried out through 14 wastewater outlets. This study emphasizes the demand to arrange effluent discharge and construction of sewage treatment plants to prevent contamination of water objects by surface run-off from residential areas and industrial territories.

  9. Removal of nutrients from combined sewer overflows and lake water in a vertical-flow constructed wetland system.

    PubMed

    Gervin, L; Brix, H

    2001-01-01

    Lake Utterslev is situated in a densely built-up area of Copenhagen, and is heavily eutrophicated from combined sewer overflows. At the same time the lake suffers from lack of water. Therefore, a 5,000 m2 vertical flow wetland system was constructed in 1998 to reduce the phosphorus discharge from combined sewer overflows without reducing the water supply to the lake. During dry periods the constructed wetland is used to remove phosphorus from the lake water. The system is designed as a 90 m diameter circular bed with a bed depth of c. 2 m. The system is isolated from the surroundings by a polyethylene membrane. The bed medium consists of a mixture of gravel and crushed marble, which has a high binding capacity for phosphorus. The bed is located within the natural littoral zone of the lake and is planted with common reed (Phragmites australis). The constructed wetland is intermittently loaded with combined sewer overflow water or lake water and, after percolation through the bed medium, the water is collected in a network of drainage pipes at the bottom of the bed and pumped to the lake. The fully automated loading cycle results in alternating wet and dry periods. During the initial two years of operation, the phosphorus removal for combined sewer overflows has been consistently high (94-99% of inflow concentrations). When loaded with lake water, the phosphorus removal has been high during summer (71-97%) and lower during winter (53-75%) partly because of lower inlet concentrations. Effluent phosphorus concentrations are consistently low (0.03-0.04 mg/L). Ammonium nitrogen is nitrified in the constructed wetland, and total suspended solids and COD are generally reduced to concentrations below 5 mg/L and 25 mg/L, respectively. The study documents that a subsurface flow constructed wetland system can be designed and operated to effectively remove phosphorus and other pollutants from combined sewer overflows and eutrophicated lake water.

  10. Analysis of heavy metal sources in storm water from urban areas

    NASA Astrophysics Data System (ADS)

    Scherer, U.; Fuchs, S.

    2009-04-01

    The input of heavy metals into surface waters is a serious impairment of the aquatic environment. The emissions of heavy metals via point and diffuse pathways into the German river basins were thus quantified for the period of 1985 through 2005. The total emission into the German river systems decreased for each metal during the observed period. This reduction is mainly caused by the decline of emissions via point sources. The measures taken by industry and implemented within the scope of a stringently water legislation have decisively contributed to an improvement of environmental conditions. Today's emissions of heavy metals into river basins of Germany are dominated by the input via diffuse pathways. One of the most important diffuse input is the storm water discharged from paved urban areas into the surface waters via storm sewers and combined sewer overflows especially for the metals copper, zinc and lead. The objective of this project was to identify the sources of these three heavy metals washed of from paved urban areas. The use of copper, zinc and lead on the outsides of buildings results in emissions to water and soil via rainwater due to weathering and runoff of soluble and insoluble metallic compounds. Copper and zinc are traditionally used materials in the building sector especially for roofs, gutters and facades. Lead, in contrast, plays only a subordinate role due to its more limited outdoor use. The corrosion rates vary widely. Climatic factors (temperature, humidity etc.), above all the presence of corrosive gases (sulphur dioxide, nitrogen oxide, ozone etc.) influence the corrosion processes. Estimates of industrial associations were referred to in order to determine the corrosion relevant metal surfaces. Heavy metal emissions caused by traffic are complex and depend on many parameters which vary by locality, time and substance. In principle, substances can be emitted by vehicles, the road surface and by maintenance. Emissions of copper, lead and zinc are mainly caused by wear and tear of tyres and brake pads. The reference figures of the environmental emissions are usually the kilometres driven per vehicle. The emissions can then be calculated based on the road performance. Furthermore atmospheric deposition on paved urban areas was considered. The heavy metal emission from each individual source and the portion discharged into surface waters via storm sewers and combined sewer overflows was quantified. The emission sum of all sources was validated using emission data of storm sewers based on measured heavy metal concentrations and the discharge volume showing a good agreement.

  11. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    PubMed

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  12. Quantifying rainfall-derived inflow and infiltration in sanitary sewer systems based on conductivity monitoring

    NASA Astrophysics Data System (ADS)

    Zhang, Mingkai; Liu, Yanchen; Cheng, Xun; Zhu, David Z.; Shi, Hanchang; Yuan, Zhiguo

    2018-03-01

    Quantifying rainfall-derived inflow and infiltration (RDII) in a sanitary sewer is difficult when RDII and overflow occur simultaneously. This study proposes a novel conductivity-based method for estimating RDII. The method separately decomposes rainfall-derived inflow (RDI) and rainfall-induced infiltration (RII) on the basis of conductivity data. Fast Fourier transform was adopted to analyze variations in the flow and water quality during dry weather. Nonlinear curve fitting based on the least squares algorithm was used to optimize parameters in the proposed RDII model. The method was successfully applied to real-life case studies, in which inflow and infiltration were successfully estimated for three typical rainfall events with total rainfall volumes of 6.25 mm (light), 28.15 mm (medium), and 178 mm (heavy). Uncertainties of model parameters were estimated using the generalized likelihood uncertainty estimation (GLUE) method and were found to be acceptable. Compared with traditional flow-based methods, the proposed approach exhibits distinct advantages in estimating RDII and overflow, particularly when the two processes happen simultaneously.

  13. Web Based Decision Support Tools for Selection of Condition Assessment and Rehabilitation Methods for Laterals (WERF Report INFR2SG09)

    EPA Science Inventory

    Abstract: It has been observed that the majority of older sewer laterals made of concrete or terracotta pipe are deteriorating rapidly. Wastewater agencies, typically responsible for maintaining the portion of the sewer lateral located in the public right-of-way, and property o...

  14. Identifying pathways for sanitary sewer pathogens to reach deep water supply wells in Madison, Wisconsin

    USDA-ARS?s Scientific Manuscript database

    Previous work conducted by the Wisconsin Geological and Natural History Survey indicated that human enteric viruses from leaking sewers are present in several municipal wells in Madison, WI. These wells are the drinking water source for the City of Madison, are typically 700 to 900 feet deep, and pe...

  15. Fiscal Accountability of the Department of Education: Tracking Responsibility for Utility Costs. A Report to the Governor and the Legislature of the State of Hawaii.

    ERIC Educational Resources Information Center

    Hawaii State Office of the Auditor, Honolulu.

    Responsibility for expenditures by schools in Hawaii for such utilities as electricity, telephone, gas, water, and sewer is shifting from the Department of Education to schools. In shifting responsibility for processing telephone and electricity payments to local schools while retaining management functions, the department failed to develop clear…

  16. Sewer-mining: A water reuse option supporting circular economy, public service provision and entrepreneurship.

    PubMed

    Makropoulos, C; Rozos, E; Tsoukalas, I; Plevri, A; Karakatsanis, G; Karagiannidis, L; Makri, E; Lioumis, C; Noutsopoulos, C; Mamais, D; Rippis, C; Lytras, E

    2018-06-15

    Water scarcity, either due to increased urbanisation or climatic variability, has motivated societies to reduce pressure on water resources mainly by reducing water demand. However, this practice alone is not sufficient to guarantee the quality of life that high quality water services underpin, especially within a context of increased urbanisation. As such, the idea of water reuse has been gaining momentum for some time and has recently found a more general context within the idea of the Circular Economy. This paper is set within the context of an ongoing discussion between centralized and decentralized water reuse techniques and the investigation of trade-offs between efficiency and economic viability of reuse at different scales. Specifically, we argue for an intermediate scale of a water reuse option termed 'sewer-mining', which could be considered a reuse scheme at the neighbourhood scale. We suggest that sewer mining (a) provides a feasible alternative reuse option when the geography of the wastewater treatment plant is problematic, (b) relies on mature treatment technologies and (c) presents an opportunity for Small Medium Enterprises (SME) to be involved in the water market, securing environmental, social and economic benefits. To support this argument, we report on a pilot sewer-mining application in Athens, Greece. The pilot, integrates two subsystems: a packaged treatment unit and an information and communications technology (ICT) infrastructure. The paper reports on the pilot's overall performance and critically evaluates the potential of the sewer-mining idea to become a significant piece of the circular economy puzzle for water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Effect and relevance of the artificial drainage system when assessing the hydrologic impact of the imperviousness distribution within the watershed

    NASA Astrophysics Data System (ADS)

    Thenoux, M.; Gironas, J. A.; Mejia, A.

    2013-12-01

    Cities and urban growth have relevant environmental and social impacts, which could eventually be enhanced or reduced during the urban planning process. From the point of view of hydrology, impermeability and natural soil compaction are one of the main problems that urbanization brings to watershed. Previous studies demonstrate and quantify the impacts of the distribution of imperviousness in a watershed, both on runoff volumes and flow, and the quality and integrity of streams and receiving bodies. Moreover, some studies have investigated the optimal distribution of imperviousness, based on simulating different scenarios of land use change and its effects on runoff, mostly at the outlet of the watershed. However, these studies typically do not address the impact of artificial drainage system associated with the imperviousness scenarios, despite it is known that storm sewer coverage affects the flow accumulation and generation of flow hydrographs. This study seeks to quantify the effects and relevance of the artificial system when it comes to assess the hydrological impacts of the spatial distribution of imperviousness and to determine the characteristics of this influence. For this purpose, an existing model to generate imperviousness distribution scenarios is coupled with a model developed to automatically generate artificial drainage networks. These models are applied to a natural watershed to generate a variety of imperviousness and storm sewer layout scenarios, which are evaluate with a morphoclimatic instantaneous unit hydrograph model. We first tested the ability of this approach to represent the joint effects of imperviousness (i.e. level and distribution) and storm sewer coverage. We then quantified the effects of these variables on the hydrological response, considering also different return period in order to take into account the variability of the precipitation regime. Overall, we show that the layout and spatial coverage of the storm sewer system affect the hydrologic response, and that these effects depend on the degree of imperviousness and the characteristics of the precipitation. Results of this research improve our understanding on how urban planning decisions can contribute to minimize the hydrologic and environmental impacts of urban development.

  18. SeWeR: a customizable and integrated dynamic HTML interface to bioinformatics services.

    PubMed

    Basu, M K

    2001-06-01

    Sequence analysis using Web Resources (SeWeR) is an integrated, Dynamic HTML (DHTML) interface to commonly used bioinformatics services available on the World Wide Web. It is highly customizable, extendable, platform neutral, completely server-independent and can be hosted as a web page as well as being used as stand-alone software running within a web browser.

  19. Tertiary Treatment and Recycling of Wastewater

    DTIC Science & Technology

    2015-05-18

    of the Worrell design (Figure 2.1) illustrates the modular treatment cells filled with vitrified expanded clay (or similar media) and planted with...General Construction Storm Water permit Sanitary / Storm Drainage Restriction: Absolutely no materials are to be disposed of via the sanitary ...sewer or storm water systems without consulting the Environmental Office. Exception: Water may be discharged down the sanitary sewer when:  The

  20. High-Throughput Amplicon Sequencing Reveals Distinct Communities within a Corroding Concrete Sewer System

    PubMed Central

    Dennis, Paul G.; Keller, Jurg; Tyson, Gene W.

    2012-01-01

    Microbially induced concrete corrosion (MICC) is an important problem in sewers. Here, small-subunit (SSU) rRNA gene amplicon pyrosequencing was used to characterize MICC communities. Microbial community composition differed between wall- and ceiling-associated MICC layers. Acidithiobacillus spp. were present at low abundances, and the communities were dominated by other sulfur-oxidizing-associated lineages. PMID:22843532

Top