Fiber pulling apparatus modification
NASA Technical Reports Server (NTRS)
Smith, Guy A.; Workman, Gary L.
1992-01-01
A reduced gravity fiber pulling apparatus (FPA) was constructed in order to study the effects of gravity on glass fiber formation. The apparatus was specifically designed and built for use on NASA's KC-135 aircraft. Four flights have been completed to date during which E-glass fiber was successfully produced in simulated zero, high, and lunar gravity environments. In addition simulated lunar soil samples were tested for their fiber producing properties using the FPA.
Test equipment data package for the KC-135 fiber pulling apparatus
NASA Technical Reports Server (NTRS)
Kosten, Sue; Smith, Guy A.; Workman, Gary; Tucker, Dennis
1991-01-01
The Fiber Pulling Apparatus (FPA) is a device designed to produce continuous glass fibers from simulated lunar soil, and to determine the effects of reduced gravity, specifically 1/6 g on fiber formation and resultant properties. Briefly, pre-melt simulated lunar soil will be placed in a pint crucible and heated to 1200 C or higher, up to a maximum temperature of 1400 C. At a given temperature, a quartz fiber will be immersed into the melt and then pulled through a chill block and wound onto a cylindrical bobbin using a servo motor control. A high resolution video camera will record the fiber as it is being pulled. This assembly wil be enclosed in Plexiglas. Before fiber pulling commences, the apparatus will be backfilled with dry nitrogen. A separate data acquisition system will support this apparatus. This system will contain a personal computer, video recorder, and monitor. Temperature, acceleration, winding speed, and video images will be controlled and recorded using the data acquisition system. Thus, the FPA will consist of two hardware packages, the fiber production assembly and the data acquisition rack. The primary objective of this test is to determine the effects of 1/6 g on the formation of continuous glass fiber made from simulated lunar soil. Baseline studies using the FPA on the ground will provide a reference for the 1/6 g studies. Of particular interest will be the effect of 1/6 g on the free fluid zone where the fiber exits the crucible. In the fiber spinning parlance this zone is known as the upper jet region, where the boundary slope is greater than one tenth. The properties of the resulting glass fiber will depend on the jet shape as well as distributions of velocity, temperature and tension within the jet. It is unknown at this time how 1/6 g will effect these parameters.
Novel Heterongineered Detectors for Multi-Color Infrared Sensing
2012-01-30
barriers”. Appl. Phys. Lett. 98, 121106 (2011) 9. A. Khoshakhlagh, F. Jaeckel C. Hains J. B. Rodriguez , L. R. Dawson, K. Malloy, and S. Krishna...AlAs etch-stop layer. The detailed processing sequence is included in the Methods. b da c n + -GaAs 200 nm Mesa lndium bump 2.1 –2.1 FPA p d SP-FPA...FPA chip. The processing scheme of the plasmonic FPA chip consists of a dry etch to form the mesa , surface passivation, ohmic metal evaporation, under
Plasmid acquisition in microgravity
NASA Technical Reports Server (NTRS)
Juergensmeyer, Margaret A.; Juergensmeyer, Elizabeth A.; Guikema, James A.
1995-01-01
In microgravity, bacteria often show an increased resistance to antibiotics. Bacteria can develop resistance to an antibiotic after transformation, the acquisition of DNA, usually in the form of a plasmid containing a gene for resistance to one or more antibiotics. In order to study the capacity of bacteria to become resistant to antibiotics in microgravity, we have modified the standard protocol for transformation of Escherichia coli for use in the NASA-flight-certified hardware package, The Fluid Processing Apparatus (FPA). Here we report on the ability of E. coli to remain competent for long periods of time at temperatures that are readily available on the Space Shuttle, and present some preliminary flight results.
NASA Technical Reports Server (NTRS)
Gallegos, Gregory L.; Odom, William R.; Guikema, James A.
1995-01-01
The study of higher plant growth and development in the microgravity (micro-g) environment continues to be a challenge. This is in part a result of the available flight qualified hardware with restrictive closed gas environments. This point is underscored by considering that gas exchange of seedlings grown in microgravity may be further limited owing to a thicker layer of water wicked onto the roots and to the absence of convective mixing. We hypothesized that seedlings grown under such conditions will experience greater hypoxia in microgravity than at Earth gravity, and thus produce greater stress ethylene. We compared flight and ground samples of sweet clover seedlings grown in the Fluid Processing Apparatus (FPA) during STS-57 and found them to contain extremely high levels of carbon dioxide (CO2) and stress ethylene. There were time dependent increases for both gases, and seedling growth was greatly inhibited. We repeated these experiments aboard STS-60 using modified chambers which increased, by fifty fold, the air available to the developing seedlings. Sweet clover seed germination and subsequent seedling growth to eight days within the FPA modified with a gas permeable membrane is not compromised by the microgravity environment.
NASA Technical Reports Server (NTRS)
Gallegos, Gregory L.; Peterson, Barbara V.; Brown, Christopher S.; Guikema, James A.
1995-01-01
Previous experiments from our lab have shown that seeds of sweet clover, when germinated and grown within the Fluid Processing Apparatus (FPA) on a slow rotating clinostat produce significantly greater levels of the volatile stress hormone, ethylene, when compared to seeds treated the same but without clinorotation. In both conditions, carbon dioxide levels reached high levels and seedling growth was inhibited. However, clinorotation inhibited growth to a greater extent. To help determine to what extent microgravity influences stress ethylene production and to what extent ethylene inhibits seedling growth, we have extended the above experiments by growing sweet clover in the presence of aminooxyacetic acid (AOA) and silver nitrate (AgNO3), inhibitors of stress ethylene biosynthesis and action, respectively. Seeds of sweet clover were germinated and grown for five days in the FPA under two gravity conditions: under stationary conditions on Earth and in microgravity onboard the space shuttle, Discovery (STS-63), which launched Feb. 3, 1995. Upon recovery, gas samples were aspirated from the growth chambers and carbon dioxide and ethylene concentrations were measured using a gas chromatograph. Then the tissue was weighed, photographed and fixed, and is current undergoing further morphological and microscopic characterization.
Simultaneous multi-beam planar array IR (pair) spectroscopy
Elmore, Douglas L.; Rabolt, John F.; Tsao, Mei-Wei
2005-09-13
An apparatus and method capable of providing spatially multiplexed IR spectral information simultaneously in real-time for multiple samples or multiple spatial areas of one sample using IR absorption phenomena requires no moving parts or Fourier Transform during operation, and self-compensates for background spectra and degradation of component performance over time. IR spectral information and chemical analysis of the samples is determined by using one or more IR sources, sampling accessories for positioning the samples, optically dispersive elements, a focal plane array (FPA) arranged to detect the dispersed light beams, and a processor and display to control the FPA, and display an IR spectrograph. Fiber-optic coupling can be used to allow remote sensing. Portability, reliability, and ruggedness is enhanced due to the no-moving part construction. Applications include determining time-resolved orientation and characteristics of materials, including polymer monolayers. Orthogonal polarizers may be used to determine certain material characteristics.
Mercury-Cadmium-Telluride Focal Plane Array Performance Under Non-Standard Operating Conditions
NASA Technical Reports Server (NTRS)
Richardson, Brandon S.; Eastwood, Michael L.; Bruce, Carl F.; Green, Robert O.; Coles, J. B.
2011-01-01
This paper highlights a new technique that allows the Teledyne Scientific & Imaging LLC TCM6604A Mercury-Cadmium-Telluride (MCT) Focal Plane Array (FPA) to operate at room temperature. The Teledyne MCT FPA has been a standard in Imaging Spectroscopy since its creation in the 1980's. This FPA has been used in applications ranging from space instruments such as CRISM, M3 and ARTEMIS to airborne instruments such as MaRS and the Next Generation AVIRIS Instruments1. Precise focal plane alignment is always a challenge for such instruments. The current FPA alignment process results in multiple cold cycles requiring week-long durations, thereby increasing the risk and cost of a project. These alignment cycles are necessary because optimal alignment is approached incrementally and can only be measured with the FPA and Optics at standard operating conditions, requiring a cold instrument. Instruments using this FPA are normally cooled to temperatures below 150K for the MCT FPA to properly function. When the FPA is run at higher temperatures the dark current increases saturating the output. This paper covers the prospect of warm MCT FPA operation from a theoretical and experimental perspective. We discuss the empirical models and physical laws that govern MCT material properties and predict the optimal settings that will result in the best MCT PA performance at 300K. Theoretical results are then calculated for the proposed settings. We finally present the images and data obtained using the actual system with the warm MCT FPA settings. The paper concludes by emphasizing the strong positive correlation between the measured values and the theoretical results.
NASA Technical Reports Server (NTRS)
Gallegos, Gregory L.; Hilaire, Emmanuel M.; Peterson, Barbara V.; Brown, Christopher S.; Guikema, James A.
1995-01-01
Starch filled plastids termed amyloplasts, contained within columella cells of the root caps of higher plant roots, are believed to play a statolith-like role in the gravitropic response of roots. Plants having amyloplasts containing less starch exhibit a corresponding reduction in gravitropic response. We have observed enhanced ethylene production by sweet clover (Melilotus alba L.) seedlings grown in the altered gravity condition of a slow rotating clinostat, and have suggested that this is a stress response resulting from continuous gravistimulation rather than as a result of the simulation of a microgravity condition. If so, we expect that plants deficient in starch accumulation in amyloplasts may produce less stress ethylene when grown on a clinostat. Therefore, we have grown Arabidopsis thaliana in the small, closed environment of the Fluid Processing Apparatus (FPA). In this preliminary report we compare stationary plants with clinorotated and those grown in microgravity aboard Discovery during the STS-63 flight in February 1995. In addition to wildtype, two mutants deficient in starch biosynthesis, mutants TC7 and TL25, which are, respectively, deficient in the activity of amyloplast phosphoglucomutase and ADP-glucose pyrophosphorylase, were grown for three days before being fixed within the FPA. Gas samples were aspirated from the growth chambers and carbon dioxide and ethylene concentations were measured using a gas chromatograph. The fixed tissue is currently undergoing further morphologic and microscopic characterization.
Tracking initially unresolved thrusting objects in 3D using a single stationary optical sensor
NASA Astrophysics Data System (ADS)
Lu, Qin; Bar-Shalom, Yaakov; Willett, Peter; Granström, Karl; Ben-Dov, R.; Milgrom, B.
2017-05-01
This paper considers the problem of estimating the 3D states of a salvo of thrusting/ballistic endo-atmospheric objects using 2D Cartesian measurements from the focal plane array (FPA) of a single fixed optical sensor. Since the initial separations in the FPA are smaller than the resolution of the sensor, this results in merged measurements in the FPA, compounding the usual false-alarm and missed-detection uncertainty. We present a two-step methodology. First, we assume a Wiener process acceleration (WPA) model for the motion of the images of the projectiles in the optical sensor's FPA. We model the merged measurements with increased variance, and thence employ a multi-Bernoulli (MB) filter using the 2D measurements in the FPA. Second, using the set of associated measurements for each confirmed MB track, we formulate a parameter estimation problem, whose maximum likelihood estimate can be obtained via numerical search and can be used for impact point prediction. Simulation results illustrate the performance of the proposed method.
Liang, Kun; Yang, Cailan; Peng, Li; Zhou, Bo
2017-02-01
In uncooled long-wave IR camera systems, the temperature of a focal plane array (FPA) is variable along with the environmental temperature as well as the operating time. The spatial nonuniformity of the FPA, which is partly affected by the FPA temperature, obviously changes as well, resulting in reduced image quality. This study presents a real-time nonuniformity correction algorithm based on FPA temperature to compensate for nonuniformity caused by FPA temperature fluctuation. First, gain coefficients are calculated using a two-point correction technique. Then offset parameters at different FPA temperatures are obtained and stored in tables. When the camera operates, the offset tables are called to update the current offset parameters via a temperature-dependent interpolation. Finally, the gain coefficients and offset parameters are used to correct the output of the IR camera in real time. The proposed algorithm is evaluated and compared with two representative shutterless algorithms [minimizing the sum of the squares of errors algorithm (MSSE), template-based solution algorithm (TBS)] using IR images captured by a 384×288 pixel uncooled IR camera with a 17 μm pitch. Experimental results show that this method can quickly trace the response drift of the detector units when the FPA temperature changes. The quality of the proposed algorithm is as good as MSSE, while the processing time is as short as TBS, which means the proposed algorithm is good for real-time control and at the same time has a high correction effect.
Scannerless laser range imaging using loss modulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandusky, John V
2011-08-09
A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate inmore » the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.« less
Scannerless laser range imaging using loss modulation
Sandusky, John V [Albuquerque, NM
2011-08-09
A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.
Xu, Zhengming; Han, Dexia; Li, Yuan; Zhang, Pingling; You, Lijun; Zhao, Zhengang
2018-04-23
In this study, the FPA90-Cl resin was magnetized with supported Fe 3 O 4 particles using a chemical co-precipitation method and its removal performance of bromate and coexisting precursors was explored. The magnetized FPA90-Cl resin was structurally characterized by SEM, FT-IR, and XRD. The effects of the initial concentrations, temperature, and resin dosage on bromate and bromide ion removal in drinking water were investigated using batch experiments. The magnetized FPA90-Cl resin exhibited a high removal efficiency for bromate and bromide ions at three initial concentrations, and the residual bromate concentrations were under the maximum contaminant level (MCL) of 10 μg L -1 after 80 min. The adsorption data of bromate and bromide ion could be well described by a pseudo-first-order kinetic model (R 2 ˃ 0.98). The bromate removal alone was further studied by varying the initial solution pH, temperature, and competitive anions. The results showed that the magnetized FPA90-Cl resin could be used over a wide pH range (4.0-9.0). The maximum sorption capacity of the magnetized FPA90-Cl resin for bromate reached 132.83 mg g -1 at 298 K. The Freundlich and Redlich-Peterson isotherm models fit the bromate adsorption equilibrium better (R 2 ˃ 0.99) than the Langmuir isotherm model (R 2 ˃ 0.98). The thermodynamic analysis showed that the bromate adsorption process was endothermic. The negative ΔG and positive ΔS indicated that the process was spontaneous and that randomness increased after adsorption, respectively. The competition of coexisting anions with bromate was in the order of SO 4 2- > CO 3 2- > Cl - > NO 3 - > HCO 3 - > PO 4 3- . Additionally, the magnetized FPA90-Cl resin could maintain a high bromate and bromide ion adsorption capacity after five cycles of regeneration by a 0.1 M NaCl solution. Graphical abstract ᅟ.
Cao, Yanpeng; Tisse, Christel-Loic
2013-09-01
In uncooled long-wave infrared (LWIR) microbolometer imaging systems, temperature fluctuations of the focal plane array (FPA) result in thermal drift and spatial nonuniformity. In this paper, we present a novel approach based on single-image processing to simultaneously estimate temperature variances of FPAs and compensate the resulting temperature-dependent nonuniformity. Through well-controlled thermal calibrations, empirical behavioral models are derived to characterize the relationship between the responses of microbolometer and FPA temperature variations. Then, under the assumption that strong dependency exists between spatially adjacent pixels, we estimate the optimal FPA temperature so as to minimize the global intensity variance across the entire thermal infrared image. We make use of the estimated FPA temperature to infer an appropriate nonuniformity correction (NUC) profile. The performance and robustness of the proposed temperature-adaptive NUC method are evaluated on realistic IR images obtained by a 640 × 512 pixels uncooled LWIR microbolometer imaging system operating in a significantly changed temperature environment.
Hyperglycemia may determine fibrinopeptide A plasma level increase in humans.
Ceriello, A; Giugliano, D; Quatraro, A; Dello Russo, P; Marchi, E; Torella, R
1989-12-01
The effects of hyperglycemia on plasma fibrinopeptide A (FPA) levels in normal subjects are reported. An increase of FPA concentration parallel to sustained hyperglycemia was observed; when the glycemia returned to basal values, FPA showed values in normal range. Heparin infusion was able to significantly decrease the hyperglycemia-induced augment of FPA levels. Isovolumic-isotonic NaCl solution infusion produced a slight (NS) increase in FPA levels; however, mild hyperglycemia, achieved by glucagon, was also able to produce a significant increase in FPA concentration. These data demonstrate the direct role of hyperglycemia in conditioning FPA level, and suggest that hyperglycemia, by itself, is a sufficient stimulus to produce thrombin activation in humans.
NASA Astrophysics Data System (ADS)
Bowers, David L.; Boger, James K.; Wellems, L. David; Black, Wiley T.; Ortega, Steve E.; Ratliff, Bradley M.; Fetrow, Matthew P.; Hubbs, John E.; Tyo, J. Scott
2006-05-01
Recent developments for Long Wave InfraRed (LWIR) imaging polarimeters include incorporating a microgrid polarizer array onto the focal plane array (FPA). Inherent advantages over typical polarimeters include packaging and instantaneous acquisition of thermal and polarimetric information. This allows for real time video of thermal and polarimetric products. The microgrid approach has inherent polarization measurement error due to the spatial sampling of a non-uniform scene, residual pixel to pixel variations in the gain corrected responsivity and in the noise equivalent input (NEI), and variations in the pixel to pixel micro-polarizer performance. The Degree of Linear Polarization (DoLP) is highly sensitive to these parameters and is consequently used as a metric to explore instrument sensitivities. Image processing and fusion techniques are used to take advantage of the inherent thermal and polarimetric sensing capability of this FPA, providing additional scene information in real time. Optimal operating conditions are employed to improve FPA uniformity and sensitivity. Data from two DRS Infrared Technologies, L.P. (DRS) microgrid polarizer HgCdTe FPAs are presented. One FPA resides in a liquid nitrogen (LN2) pour filled dewar with a 80°K nominal operating temperature. The other FPA resides in a cryogenic (cryo) dewar with a 60° K nominal operating temperature.
Strategies for Choosing Descent Flight-Path Angles for Small Jets
NASA Technical Reports Server (NTRS)
Wu, Minghong Gilbert; Green, Steven M.
2012-01-01
Three candidate strategies for choosing the descent flight path angle (FPA) for small jets are proposed, analyzed, and compared for fuel efficiency under arrival metering conditions. The strategies vary in operational complexity from a universally fixed FPA, or FPA function that varies with descent speed for improved fuel efficiency, to the minimum-fuel FPA computed for each flight based on winds, route, and speed profile. Methodologies for selecting the parameter for the first two strategies are described. The differences in fuel burn are analyzed over a year s worth of arrival traffic and atmospheric conditions recorded for the Dallas/Fort Worth (DFW) Airport during 2011. The results show that the universally fixed FPA strategy (same FPA for all flights, all year) burns on average 26 lbs more fuel per flight as compared to the minimum-fuel solution. This FPA is adapted to the arrival gate (direction of entry to the terminal) and various timespans (season, month and day) to improve fuel efficiency. Compared to a typical FPA of approximately 3 degrees the adapted FPAs vary significantly, up to 1.3 from one arrival gate to another or up to 1.4 from one day to another. Adapting the universally fixed FPA strategy to the arrival gate or to each day reduces the extra fuel burn relative to the minimum-fuel solution by 27% and 34%, respectively. The adaptations to gate and time combined shows up to 57% reduction of the extra fuel burn. The second strategy, an FPA function, contributes a 17% reduction in the 26 lbs of extra fuel burn over the universally fixed FPA strategy. Compared to the corresponding adaptations of the universally fixed FPA, adaptations of the FPA function reduce the extra fuel burn anywhere from 15-23% depending on the extent of adaptation. The combined effect of the FPA function strategy with both directional and temporal adaptation recovers 67% of the extra fuel relative to the minimum-fuel solution.
3rd-generation MW/LWIR sensor engine for advanced tactical systems
NASA Astrophysics Data System (ADS)
King, Donald F.; Graham, Jason S.; Kennedy, Adam M.; Mullins, Richard N.; McQuitty, Jeffrey C.; Radford, William A.; Kostrzewa, Thomas J.; Patten, Elizabeth A.; McEwan, Thomas F.; Vodicka, James G.; Wootan, John J.
2008-04-01
Raytheon has developed a 3rd-Generation FLIR Sensor Engine (3GFSE) for advanced U.S. Army systems. The sensor engine is based around a compact, productized detector-dewar assembly incorporating a 640 x 480 staring dual-band (MW/LWIR) focal plane array (FPA) and a dual-aperture coldshield mechanism. The capability to switch the coldshield aperture and operate at either of two widely-varying f/#s will enable future multi-mode tactical systems to more fully exploit the many operational advantages offered by dual-band FPAs. RVS has previously demonstrated high-performance dual-band MW/LWIR FPAs in 640 x 480 and 1280 x 720 formats with 20 μm pitch. The 3GFSE includes compact electronics that operate the dual-band FPA and variable-aperture mechanism, and perform 14-bit analog-to-digital conversion of the FPA output video. Digital signal processing electronics perform "fixed" two-point non-uniformity correction (NUC) of the video from both bands and optional dynamic scene-based NUC; advanced enhancement processing of the output video is also supported. The dewar-electronics assembly measures approximately 4.75 x 2.25 x 1.75 inches. A compact, high-performance linear cooler and cooler electronics module provide the necessary FPA cooling over a military environmental temperature range. 3GFSE units are currently being assembled and integrated at RVS, with the first units planned for delivery to the US Army.
Implementation of a noise reduction circuit for spaceflight IR spectrometers
NASA Technical Reports Server (NTRS)
Ramirez, L.; Hickok, R.; Pain, B.; Staller, C.
1992-01-01
The paper discusses the implementation and analysis of a correlated triple sampling circuit using analog subtractor/integrators. The software and test setup for noise measurements are also described. The correlation circuitry is part of the signal chain for a 256-element InSb line array used in the Visible and Infrared Mapping Spectrometer. Using a focal-plane array (FPA) simulator, system noise measurements of 0.7 DN are obtained. A test setup for FPA/SPE (signal processing electronics) characterization along with noise measurements is demonstrated.
High speed imager test station
Yates, George J.; Albright, Kevin L.; Turko, Bojan T.
1995-01-01
A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment.
High speed imager test station
Yates, G.J.; Albright, K.L.; Turko, B.T.
1995-11-14
A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment. 12 figs.
Isolation and characterization of a cysteine protease of freesia corms.
Uchikoba, Tetsuya; Okubo, Michiko; Arima, Kazunari; Yonezawa, Hiroo
2002-02-01
A protease, freesia protease (FP)-A, was purified to electrophoretic homogeneity from regular freesia (Freesia reflacta) corms in harvest time. The Mr of FP-A was estimated to be 24 k by SDS-PAGE. The optimum pH of the enzyme was 8.0 using a casein substrate. These enzymes were strongly inhibited by p-chloromercuribenzoic acid but not by phenylmethane-sulfonylfluoride and EDTA. These results indicate that FP-A belongs to the cysteine proteases. The amino terminal sequence of FP-A was similar to that of papain, and the sequences was regarded to the conservative residues of cysteine protease. From the hydrolysis of peptidyl-p-NAs, the specificity of FP-A was found to be broad. It was thought that FP-A was a new protease from freesia corms.
Multi-band infrared camera systems
NASA Astrophysics Data System (ADS)
Davis, Tim; Lang, Frank; Sinneger, Joe; Stabile, Paul; Tower, John
1994-12-01
The program resulted in an IR camera system that utilizes a unique MOS addressable focal plane array (FPA) with full TV resolution, electronic control capability, and windowing capability. Two systems were delivered, each with two different camera heads: a Stirling-cooled 3-5 micron band head and a liquid nitrogen-cooled, filter-wheel-based, 1.5-5 micron band head. Signal processing features include averaging up to 16 frames, flexible compensation modes, gain and offset control, and real-time dither. The primary digital interface is a Hewlett-Packard standard GPID (IEEE-488) port that is used to upload and download data. The FPA employs an X-Y addressed PtSi photodiode array, CMOS horizontal and vertical scan registers, horizontal signal line (HSL) buffers followed by a high-gain preamplifier and a depletion NMOS output amplifier. The 640 x 480 MOS X-Y addressed FPA has a high degree of flexibility in operational modes. By changing the digital data pattern applied to the vertical scan register, the FPA can be operated in either an interlaced or noninterlaced format. The thermal sensitivity performance of the second system's Stirling-cooled head was the best of the systems produced.
NASA Astrophysics Data System (ADS)
Gunapala, Sarath D.; Bandara, Sumith V.; Singh, Anjali; Liu, John K.; Rafol, S. B.; Luong, Edward M.; Mumolo, Jason M.; Tran, N. Q.; Vincent, John D.; Shott, C. A.; Long, James F.; LeVan, Paul D.
1999-07-01
An optimized long-wavelength two-color quantum well IR photodetector (QWIP) device structure has been designed. This device structure was grown on a three-inch semi- insulating GaAs substrate by molecule beam epitaxy (MBE). This wafer was processed into several 640 X 486 format monolithically integrated 8-9 and 14-15 micrometers two-color QWIP focal plane arrays (FPAs). These FPAs were then hybridized to 640 X 486 silicon CMOS readout multiplexers. A thinned FPA hybrid was integrated into a liquid helium cooled dewar to perform electrical and optical characterization and to demonstrate simultaneous two-color imagery. The 8-9 micrometers detectors in the FPA have shown background limited performance (BLIP) at 70 K operating temperature, at 300 K background with f/2 cold stop. The 14-15 micrometers detectors of the FPA have reached BLIP at 40 K operating temperature at the same background conditions. In this paper we discuss the performance of this long-wavelength dualband QWIP FPA in quantum efficiency, detectivity, noise equivalent temperature difference, uniformity, and operability.
NASA Astrophysics Data System (ADS)
Gunapala, S. D.; Bandara, S. V.; Singh, A.; Liu, J. K.; Rafol, S. B.
2000-01-01
We have designed and fabricated an optimized long-wavelength/very-long-wavelength two-color quantum well infrared photodetector (QWIP) device structure. The device structure was grown on a 3-in semi-insulating GaAs substrate by molecular beam epitaxy (MBE). The wafer was processed into several 640 x 486 format monolithically integrated 8-9 and 14-15 micrometers two-color (or dual wavelength) QWIP focal plane arrays (FPA's). These FPA's were then hybridized to 640 x 486 silicon CMOS readout multiplexers. A thinned (i.e., substrate removed) FPA hybrid was integrated into liquid helium cooled dewar for electrical and optical characterization and to demonstrate simultaneous two-color imagery. The 8-9 micrometers detectors in the FPA have shown background limited performance (BLIP) at 70 K operating temperature for 300 K background with f/2 cold stop. The 14-15 micrometers detectors of the SPA reach BLIP at 40 K operating temperature under the same background conditions. In this paper we discuss the performance of this long-wavelength dualband QWIP SPA in terms of quantum efficiency, detectivity, noise equivalent temperature difference (NE DELTA T), uniformity, and operability.
Hara, Naomi; Nishimura, Yukika; Yokoyama, Chika; Inoue, Ken; Nishida, Atsushi; Tanii, Hisashi; Okada, Motohiro; Kaiya, Hisanobu; Okazaki, Yuji
2012-04-11
The place where a patient experiences his/her first panic attack (FPA) may be related to their agoraphobia later in life. However, no investigations have been done into the clinical features according to the place where the FPA was experienced. In particular, there is an absence of detailed research examining patients who experienced their FPA at home. In this study, patients were classified by the location of their FPA and the differences in their clinical features were explored (e.g., symptoms of FPA, frequency of agoraphobia, and severity of FPA). The subjects comprised 830 panic disorder patients who were classified into 5 groups based on the place of their FPA (home, school/office, driving a car, in a public transportation vehicle, outside of home), The clinical features of these patients were investigated. Additionally, for panic disorder patients with agoraphobia at their initial clinic visit, the clinical features of patients who experienced their FPA at home were compared to those who experienced their attack elsewhere. In comparison of the FPAs of the 5 groups, significant differences were seen among the 7 descriptors (sex ratio, drinking status, smoking status, severity of the panic attack, depression score, ratio of agoraphobia, and degree of avoidance behavior) and 4 symptoms (sweating, chest pain, feeling dizzy, and fear of dying). The driving and public transportation group patients showed a higher incidence of co-morbid agoraphobia than did the other groups. Additionally, for panic disorder patients with co-morbid agoraphobia, the at-home group had a higher frequency of fear of dying compared to the patients in the outside-of-home group and felt more severe distress elicited by their FPA. The results of this study suggest that the clinical features of panic disorder patients vary according to the place of their FPA. The at-home group patients experienced "fear of dying" more frequently and felt more distress during their FPA than did the subjects in the other groups. These results indicate that patients experiencing their FPA at home should be treated with a focus on the fear and distress elicited by the attack.
2012-01-01
Background The place where a patient experiences his/her first panic attack (FPA) may be related to their agoraphobia later in life. However, no investigations have been done into the clinical features according to the place where the FPA was experienced. In particular, there is an absence of detailed research examining patients who experienced their FPA at home. In this study, patients were classified by the location of their FPA and the differences in their clinical features were explored (e.g., symptoms of FPA, frequency of agoraphobia, and severity of FPA). Methods The subjects comprised 830 panic disorder patients who were classified into 5 groups based on the place of their FPA (home, school/office, driving a car, in a public transportation vehicle, outside of home), The clinical features of these patients were investigated. Additionally, for panic disorder patients with agoraphobia at their initial clinic visit, the clinical features of patients who experienced their FPA at home were compared to those who experienced their attack elsewhere. Results In comparison of the FPAs of the 5 groups, significant differences were seen among the 7 descriptors (sex ratio, drinking status, smoking status, severity of the panic attack, depression score, ratio of agoraphobia, and degree of avoidance behavior) and 4 symptoms (sweating, chest pain, feeling dizzy, and fear of dying). The driving and public transportation group patients showed a higher incidence of co-morbid agoraphobia than did the other groups. Additionally, for panic disorder patients with co-morbid agoraphobia, the at-home group had a higher frequency of fear of dying compared to the patients in the outside-of-home group and felt more severe distress elicited by their FPA. Conclusion The results of this study suggest that the clinical features of panic disorder patients vary according to the place of their FPA. The at-home group patients experienced "fear of dying" more frequently and felt more distress during their FPA than did the subjects in the other groups. These results indicate that patients experiencing their FPA at home should be treated with a focus on the fear and distress elicited by the attack. PMID:22494552
2013-01-01
Background The relationship between torsional bony deformities and rotational gait parameters has not been sufficiently investigated. This study was to investigate the degree of contribution of torsional bony deformities to rotational gait parameters in patients with diplegic cerebral palsy (CP). Methods Thirty three legs from 33 consecutive ambulatory patients (average age 9.5 years, SD 6.9 years; 20 males and 13 females) with diplegic CP who underwent preoperative three dimensional gait analysis, foot radiographs, and computed tomography (CT) were included. Adjusted foot progression angle (FPA) was retrieved from gait analysis by correcting pelvic rotation from conventional FPA, which represented the rotational gait deviation of the lower extremity from the tip of the femoral head to the foot. Correlations between rotational gait parameters (FPA, adjusted FPA, average pelvic rotation, average hip rotation, and average knee rotation) and radiologic measurements (acetabular version, femoral anteversion, knee torsion, tibial torsion, and anteroposteriortalo-first metatarsal angle) were analyzed. Multiple regression analysis was performed to identify significant contributing radiographic measurements to adjusted FPA. Results Adjusted FPA was significantly correlated with FPA (r=0.837, p<0.001), contralateral FPA (r=0.492, p=0.004), pelvic rotation during gait (r=−0.489, p=0.004), knee rotation during gait (r=0.376, p=0.031), and femoral anteversion (r=0.350, p=0.046). In multiple regression analysis, femoral anteversion (p=0.026) and tibial torsion (p=0.034) were found to be the significant contributing structural deformities to the adjusted FPA (R2=0.247). Conclusions Femoral anteversion and tibial torsion were found to be the significant structural deformities that could affect adjusted FPA in patients with diplegic CP. Femoral anteversion and tibial torsion could explain only 24.7% of adjusted FPA. PMID:23767833
NASA Technical Reports Server (NTRS)
Vural, Kadri; Blessinger, Michael; Chen, Jenkon; Kleinhans, William
1989-01-01
Researchers developed a HgCdTe 256x256 focal plane array (FPA) which operates in the 1 to 5 micron band. This is presently the largest demonstrated HgCdTe FPA. The detector material is HgCdTe on sapphire (PACE-1 technology) which has a low thermal expansion mismatch with silicon. The multiplexer is a CMOS FET-switch device processed through a commercial silicon foundry. The multiplexer input is direct injection and the charge capacity is about 2 times 10 to the 7th power electrons. The kTC limited read noise is 400 electrons. Researchers demonstrated high background imaging using the device. The broadband quantum efficiency is measured to be 59 percent. Dark currents less than 0.1 pA were measured at 77 K for detectors processed on PACE-1 material with 4.9 microns cutoff. The dark currents decrease as the temperature is lowered, and researchers are presently studying the T less than 77 K characteristics. The interconnect yield is greater than 95 percent. The devices are available for astronomical applications.
Precise annealing of focal plane arrays for optical detection
Bender, Daniel A.
2015-09-22
Precise annealing of identified defective regions of a Focal Plane Array ("FPA") (e.g., exclusive of non-defective regions of the FPA) facilitates removal of defects from an FPA that has been hybridized and/or packaged with readout electronics. Radiation is optionally applied under operating conditions, such as under cryogenic temperatures, such that performance of an FPA can be evaluated before, during, and after annealing without requiring thermal cycling.
Precise annealing of focal plane arrays for optical detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bender, Daniel A.
2017-10-17
Precise annealing of identified defective regions of a Focal Plane Array ("FPA") (e.g., exclusive of non-defective regions of the FPA) facilitates removal of defects from an FPA that has been hybridized and/or packaged with readout electronics. Radiation is optionally applied under operating conditions, such as under cryogenic temperatures, such that performance of an FPA can be evaluated before, during, and after annealing without requiring thermal cycling.
Stent Design Affects Femoropopliteal Artery Deformation.
MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey
2018-03-23
Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.
Mutekwa, V T; Gambiza, J
2017-08-01
In this literature review based paper we explored the concept of exclusion of local communities from accessing resources in forest protected areas (FPAs) in Zimbabwe. We discussed the colonial and post-colonial forms, causes and mechanisms of exclusion and their social, economic and ecological outcomes. We examined the range of powers embodied in and exercised through various mechanisms, processes and social relations and their impact on local communities' access to FPA resources and associated benefits along the historical trajectory of forest governance in Zimbabwe. Results showed that the forms and extent of exclusion changed over time in tandem with the shifting political and economic landscape. During the colonial period, it was total exclusion whereby people were evicted from forest land as well as being denied access to basic resources for their livelihoods. Local communities' access to low value FPA resources improved during the post-colonial period but access to high value resources like commercial timber as well as sharing income benefits derived from FPA commercial activities remained a pipe dream. Regulation, legitimation, force and markets constituted the mixture of the power elements that FPA governing authorities used to exclude local communities. These powers remained intact despite attempts at collaborative governance in the 1990s. However, from the year 2000, local communities expressed their dissatisfaction with the centralised exclusionary governance system by invading the FPAs rendering them ungovernable. There is therefore a need for policy reform within the FPA sector to improve the current dire situation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Evolution of miniature detectors and focal plane arrays for infrared sensors
NASA Astrophysics Data System (ADS)
Watts, Louis A.
1993-06-01
Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.
Evolution of miniature detectors and focal plane arrays for infrared sensors
NASA Technical Reports Server (NTRS)
Watts, Louis A.
1993-01-01
Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.
NASA Astrophysics Data System (ADS)
Kastek, Mariusz; PiÄ tkowski, Tadeusz; Polakowski, Henryk; Barela, Jaroslaw; Firmanty, Krzysztof; Trzaskawka, Piotr; Vergara, German; Linares, Rodrigo; Gutierrez, Raul; Fernandez, Carlos; Montojo Supervielle, Maria Teresa
2014-05-01
The paper presents some aspects of muzzle flash detection using low resolution polycrystalline PbSe 32×32 and 80×80 detectors FPA operating at room temperature (uncooled performance). These sensors, which detect in MWIR (3 - 5 microns region) and are manufactured using proprietary technology from New Infrared Technologies (VPD PbSe - Vapor Phase Deposition of polycrystalline PbSe), can be applied to muzzle flash detection. The system based in the uncooled 80×80 FPA monolithically integrated with the CMOS readout circuitry has allowed image recording with frame rates over 2000 Hz (true snapshot acquisition), whereas the lower density, uncooled 32×32 FPA is suitable for being used in low cost infrared imagers sensitive in the MWIR band with frame rates above 1000 Hz. The FPA detector, read-out electronics and processing electronics (allows the implementation of some algorithms for muzzle flash detection) of both systems are presented. The systems have been tested at field test ground. Results of detection range measurement with two types of optical systems (wide and narrow field of view) have been shown. The theoretical analysis of possibility detection of muzzle flash and initial results of testing of some algorithms for muzzle flash detection have been presented too.
Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee
2018-01-01
Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.
Type II superlattice technology for LWIR detectors
NASA Astrophysics Data System (ADS)
Klipstein, P. C.; Avnon, E.; Azulai, D.; Benny, Y.; Fraenkel, R.; Glozman, A.; Hojman, E.; Klin, O.; Krasovitsky, L.; Langof, L.; Lukomsky, I.; Nitzani, M.; Shtrichman, I.; Rappaport, N.; Snapi, N.; Weiss, E.; Tuito, A.
2016-05-01
SCD has developed a range of advanced infrared detectors based on III-V semiconductor heterostructures grown on GaSb. The XBn/XBp family of barrier detectors enables diffusion limited dark currents, comparable with MCT Rule-07, and high quantum efficiencies. This work describes some of the technical challenges that were overcome, and the ultimate performance that was finally achieved, for SCD's new 15 μm pitch "Pelican-D LW" type II superlattice (T2SL) XBp array detector. This detector is the first of SCD's line of high performance two dimensional arrays working in the LWIR spectral range, and was designed with a ~9.3 micron cut-off wavelength and a format of 640 x 512 pixels. It contains InAs/GaSb and InAs/AlSb T2SLs, engineered using k • p modeling of the energy bands and photo-response. The wafers are grown by molecular beam epitaxy and are fabricated into Focal Plane Array (FPA) detectors using standard FPA processes, including wet and dry etching, indium bump hybridization, under-fill, and back-side polishing. The FPA has a quantum efficiency of nearly 50%, and operates at 77 K and F/2.7 with background limited performance. The pixel operability of the FPA is above 99% and it exhibits a stable residual non uniformity (RNU) of better than 0.04% of the dynamic range. The FPA uses a new digital read-out integrated circuit (ROIC), and the complete detector closely follows the interfaces of SCD's MWIR Pelican-D detector. The Pelican- D LW detector is now in the final stages of qualification and transfer to production, with first prototypes already integrated into new electro-optical systems.
Mancini-Filho, Jorge; Novoa, Alexis Vidal; González, Ana Elsa Batista; de Andrade-Wartha, Elma Regina S; de O e Silva, Ana Mara; Pinto, José Ricardo; Mancini, Dalva Assunção Portari
2009-01-01
Phenolic compounds are found in seaweed species together with other substances presenting antioxidant activity. The objective of this work was to evaluate the antioxidant activity of the free phenolic acids (FPA) fraction from the seaweed Halimeda monile, and its activity to protect the expression of hepatic enzymes in rats, under experimental CCl4 injury. The antioxidant activity was measured by the DPPH method. The FPA fraction (80 mg/kg, p.o.) was administered during 20 consecutive days to rats. The peroxidation was performed by thiobarbituric acid reactive substances (TBARS). The SOD and CAT enzymatic expressions were measured by RT/PCR. The histology technique was used to evaluate liver injuries. The expression of both, CAT and SOD genes, was more preserved by FPA. Only partial injury could be observed by histology in the liver of rats receiving FPA as compared with the control group; and CCl4 administration induced 60% more peroxidation as compared with the rats receiving FPA. These data suggest that FPA could modulate the antioxidant enzymes and oxidative status in the liver through protection against adverse effects induced by chemical agents.
Multi sensor satellite imagers for commercial remote sensing
NASA Astrophysics Data System (ADS)
Cronje, T.; Burger, H.; Du Plessis, J.; Du Toit, J. F.; Marais, L.; Strumpfer, F.
2005-10-01
This paper will discuss and compare recent refractive and catodioptric imager designs developed and manufactured at SunSpace for Multi Sensor Satellite Imagers with Panchromatic, Multi-spectral, Area and Hyperspectral sensors on a single Focal Plane Array (FPA). These satellite optical systems were designed with applications to monitor food supplies, crop yield and disaster monitoring in mind. The aim of these imagers is to achieve medium to high resolution (2.5m to 15m) spatial sampling, wide swaths (up to 45km) and noise equivalent reflectance (NER) values of less than 0.5%. State-of-the-art FPA designs are discussed and address the choice of detectors to achieve these performances. Special attention is given to thermal robustness and compactness, the use of folding prisms to place multiple detectors in a large FPA and a specially developed process to customize the spectral selection with the need to minimize mass, power and cost. A refractive imager with up to 6 spectral bands (6.25m GSD) and a catodioptric imager with panchromatic (2.7m GSD), multi-spectral (6 bands, 4.6m GSD), hyperspectral (400nm to 2.35μm, 200 bands, 15m GSD) sensors on the same FPA will be discussed. Both of these imagers are also equipped with real time video view finding capabilities. The electronic units could be subdivided into the Front-End Electronics and Control Electronics with analogue and digital signal processing. A dedicated Analogue Front-End is used for Correlated Double Sampling (CDS), black level correction, variable gain and up to 12-bit digitizing and high speed LVDS data link to a mass memory unit.
Dual-band QWIP MWIR/LWIR focal plane array test results
NASA Astrophysics Data System (ADS)
Goldberg, Arnold C.; Fischer, Theodore; Kennerly, Stephen; Wang, Samuel C.; Sundaram, Mani; Uppal, Parvez; Winn, Michael L.; Milne, Gregory L.; Stevens, Mark A.
2000-07-01
We report on the results of laboratory and field tests on a pixel-registered, 2-color MWIR/LWIR 256 X 256 QWIP FPA with simultaneous integrating capability. The FPA studied contained stacked QWIP structures with spectral peaks at 5.1 micrometer and 9.0 micrometer. Normally incident radiation was coupled into the devices using a diffraction grating designed to operate in both spectral bands. Each pixel is connected to the read-out integrated circuit by three bumps to permit the application of separate bias levels to each QWIP stack and allow simultaneous integration of the signal current in each band. We found the FPA to have high pixel operability, well balanced response, good imaging performance, high optical fill factor, and low spectral crosstalk. We present data on measurements of the noise-equivalent temperature difference of the FPA in both bands as functions of temperature and bias. The FPA data are compared to single-pixel data taken on devices from the same wafer. We also present data on the sensitivity of this FPA to polarized light. It is found that the LWIR portion of the device is very sensitive to the direction of polarization of the incident light. The MWIR part of the device is relatively insensitive to the polarization. In addition, imagery was taken with this FPA of military targets in the field. Image fusion techniques were applied to the resulting images.
Cossey, D
1993-01-01
In the UK, the Chairwoman of the Family Planning Association (FPA) praises the staff and volunteers with whom she has worked for their incessant inability to meet the many challenges they face. During her 6 years, however, the FPA had to reduce the number of regional offices and staff. It did not need to reduce salaries, however. FPA membership directly elects the National Executive Council which is now smaller. FPA is exploring new sources of funding and is adapting to the purchaser/provider relationship in the statutory sector, resulting in its successful financial strategy. The Department of Health helps in maintaining FPA's ability to continue to operate. The Chairwoman sees indications of needing to fight old battles again, e.g., some officials have suggested limiting the range of oral contraceptives available from prescription by the National Health Services (NHS) which would be the end of almost 20 years of free contraception and free choice under the NHS. The government is not open to including sex education the school curriculum. The NHS gives the impression in its report "The Health of the Nation" that it is committed to reducing adolescent pregnancies among the youngest teenagers and to recognizing the importance of good policies on sexual health. Yet, its actions exhibit no compassion for single parents. Participants at FPA's 1992 conference agree that variety, quality, and sensitivity of family planning provisions are needed and that family planning clinics and general practitioners should work together. FPA has contributed to the UK the clinic network; the concept of family planning being an integral part of a comprehensive health service; and the notion that family planning includes contraception, empowerment of women, sexual health, rights, and responsibilities. FPA should reaffirm these ideas and secure the future for informed choice and planned pregnancy.
Hybrid flower pollination algorithm strategies for t-way test suite generation.
Nasser, Abdullah B; Zamli, Kamal Z; Alsewari, AbdulRahman A; Ahmed, Bestoun S
2018-01-01
The application of meta-heuristic algorithms for t-way testing has recently become prevalent. Consequently, many useful meta-heuristic algorithms have been developed on the basis of the implementation of t-way strategies (where t indicates the interaction strength). Mixed results have been reported in the literature to highlight the fact that no single strategy appears to be superior compared with other configurations. The hybridization of two or more algorithms can enhance the overall search capabilities, that is, by compensating the limitation of one algorithm with the strength of others. Thus, hybrid variants of the flower pollination algorithm (FPA) are proposed in the current work. Four hybrid variants of FPA are considered by combining FPA with other algorithmic components. The experimental results demonstrate that FPA hybrids overcome the problems of slow convergence in the original FPA and offers statistically superior performance compared with existing t-way strategies in terms of test suite size.
Hybrid flower pollination algorithm strategies for t-way test suite generation
Zamli, Kamal Z.; Alsewari, AbdulRahman A.
2018-01-01
The application of meta-heuristic algorithms for t-way testing has recently become prevalent. Consequently, many useful meta-heuristic algorithms have been developed on the basis of the implementation of t-way strategies (where t indicates the interaction strength). Mixed results have been reported in the literature to highlight the fact that no single strategy appears to be superior compared with other configurations. The hybridization of two or more algorithms can enhance the overall search capabilities, that is, by compensating the limitation of one algorithm with the strength of others. Thus, hybrid variants of the flower pollination algorithm (FPA) are proposed in the current work. Four hybrid variants of FPA are considered by combining FPA with other algorithmic components. The experimental results demonstrate that FPA hybrids overcome the problems of slow convergence in the original FPA and offers statistically superior performance compared with existing t-way strategies in terms of test suite size. PMID:29718918
Linear antenna array optimization using flower pollination algorithm.
Saxena, Prerna; Kothari, Ashwin
2016-01-01
Flower pollination algorithm (FPA) is a new nature-inspired evolutionary algorithm used to solve multi-objective optimization problems. The aim of this paper is to introduce FPA to the electromagnetics and antenna community for the optimization of linear antenna arrays. FPA is applied for the first time to linear array so as to obtain optimized antenna positions in order to achieve an array pattern with minimum side lobe level along with placement of deep nulls in desired directions. Various design examples are presented that illustrate the use of FPA for linear antenna array optimization, and subsequently the results are validated by benchmarking along with results obtained using other state-of-the-art, nature-inspired evolutionary algorithms such as particle swarm optimization, ant colony optimization and cat swarm optimization. The results suggest that in most cases, FPA outperforms the other evolutionary algorithms and at times it yields a similar performance.
Noise characteristics analysis of short wave infrared InGaAs focal plane arrays
NASA Astrophysics Data System (ADS)
Yu, Chunlei; Li, Xue; Yang, Bo; Huang, Songlei; Shao, Xiumei; Zhang, Yaguang; Gong, Haimei
2017-09-01
The increasing application of InGaAs short wave infrared (SWIR) focal plane arrays (FPAs) in low light level imaging requires ultra-low noise FPAs. This paper presents the theoretical analysis of FPA noise, and point out that both dark current and detector capacitance strongly affect the FPA noise. The impact of dark current and detector capacitance on FPA noise is compared in different situations. In order to obtain low noise performance FPAs, the demand for reducing detector capacitance is higher especially when pixel pitch is smaller, integration time is shorter, and integration capacitance is larger. Several InGaAs FPAs were measured and analyzed, the experiments' results could be well fitted to the calculated results. The study found that the major contributor of FPA noise is coupled noise with shorter integration time. The influence of detector capacitance on FPA noise is more significant than that of dark current. To investigate the effect of detector performance on FPA noise, two kinds of photodiodes with different concentration of the absorption layer were fabricated. The detectors' performance and noise characteristics were measured and analyzed, the results are consistent with that of theoretical analysis.
NASA Technical Reports Server (NTRS)
Gunapala, S. D.; Bandara, S. V.
2004-01-01
A 640x512 pixel, long-wavelength cutoff, narrow-band (delta(lambda)/approx. 10%) quantum well infrared photodetector (QWIP) focal plane array (FPA), a four-band QWIP FPA in the 4-16 m spectral region, and a broad-band (delta(lambda)/approx. 42%) QWIP FPA having 15.4 m cutoff have been demonstrated.
Microplate-based filter paper assay to measure total cellulase activity.
Xiao, Zhizhuang; Storms, Reginald; Tsang, Adrian
2004-12-30
The standard filter paper assay (FPA) published by the International Union of Pure and Applied Chemistry (IUPAC) is widely used to determine total cellulase activity. However, the IUPAC method is not suitable for the parallel analyses of large sample numbers. We describe here a microplate-based method for assaying large sample numbers. To achieve this, we reduced the enzymatic reaction volume to 60 microl from the 1.5 ml used in the IUPAC method. The modified 60-microl format FPA can be carried out in 96-well assay plates. Statistical analyses showed that the cellulase activities of commercial cellulases from Trichoderma reesei and Aspergillus species determined with our 60-microl format FPA were not significantly different from the activities measured with the standard FPA. Our results also indicate that the 60-microl format FPA is quantitative and highly reproducible. Moreover, the addition of excess beta-glucosidase increased the sensitivity of the assay by up to 60%. 2004 Wiley Periodicals, Inc.
High-Performance LWIR Superlattice Detectors and FPA Based on CBIRD Design
NASA Technical Reports Server (NTRS)
Soibel, Alexander; Nguyen, Jean; Khoshakhlagh, Arezou; Rafol, Sir B.; Hoeglund, Linda; Keo, Sam A.; Mumolo, Jason M.; Liu, John; Liao, Anna; Ting, David Z.-Y.;
2012-01-01
We report our recent efforts on advancing of antimonide superlattice based infrared photodetectors and demonstration of Focal Plane Arrays (FPA) based on a complementary barrier infrared detector (CBIRD) design. By optimizing design and growth condition we succeeded to reduce the operational bias of CBIRD single pixel detector without increase of dark current or degradation of quantum efficiency. We demonstrated a 1024x1024 pixel long-wavelength infrared focal plane array utilizing CBIRD design. An 11.5 ?m cutoff FPA without anti-reflection coating has yielded noise equivalent differential temperature of 53 mK at operating temperature of 80 K, with 300 K background and cold-stop. In addition, we demonstrated 320x256 format FPA based on the n-CBIRD design. The resulting FPAs yielded noise equivalent differential temperature of 26 mK at operating temperature of 80 K, with 300 K background and cold-stop. These results advance state-of-the art of superlattice detectors and demonstrated advantages of CBIRD architecture for realization of FPA.
Development of Thermal Infrared Sensor to Supplement Operational Land Imager
NASA Technical Reports Server (NTRS)
Shu, Peter; Waczynski, Augustyn; Kan, Emily; Wen, Yiting; Rosenberry, Robert
2012-01-01
The thermal infrared sensor (TIRS) is a quantum well infrared photodetector (QWIP)-based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a far-infrared imager operating in the pushbroom mode with two IR channels: 10.8 and 12 m. The focal plane will contain three 640 512 QWIP arrays mounted onto a silicon substrate. The readout integrated circuit (ROIC) addresses each pixel on the QWIP arrays and reads out the pixel value (signal). The ROIC is controlled by the focal plane electronics (FPE) by means of clock signals and bias voltage value. The means of how the FPE is designed to control and interact with the TIRS focal plane assembly (FPA) is the basis for this work. The technology developed under the FPE is for the TIRS focal plane assembly (FPA). The FPE must interact with the FPA to command and control the FPA, extract analog signals from the FPA, and then convert the analog signals to digital format and send them via a serial link (USB) to a computer. The FPE accomplishes the described functions by converting electrical power from generic power supplies to the required bias power that is needed by the FPA. The FPE also generates digital clocking signals and shifts the typical transistor-to-transistor logic (TTL) to }5 V required by the FPA. The FPE also uses an application- specific integrated circuit (ASIC) named System Image, Digitizing, Enhancing, Controlling, And Retrieving (SIDECAR) from Teledyne Corp. to generate the clocking patterns commanded by the user. The uniqueness of the FPE for TIRS lies in that the TIRS FPA has three QWIP detector arrays, and all three detector arrays must be in synchronization while in operation. This is to avoid data skewing while observing Earth flying in space. The observing scenario may be customized by uploading new control software to the SIDECAR.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-22
... the Alternatives Process in Hydropower Licensing, OMB Control Number 1094-0001. FOR FURTHER... Interior, and Commerce collect the information covered by 1094-0001. Under FPA section 33, the Secretary of... Control Number: 1094-0001. Current Expiration Date: September 30, 2012. Type of Review: Information...
NeuroSeek dual-color image processing infrared focal plane array
NASA Astrophysics Data System (ADS)
McCarley, Paul L.; Massie, Mark A.; Baxter, Christopher R.; Huynh, Buu L.
1998-09-01
Several technologies have been developed in recent years to advance the state of the art of IR sensor systems including dual color affordable focal planes, on-focal plane array biologically inspired image and signal processing techniques and spectral sensing techniques. Pacific Advanced Technology (PAT) and the Air Force Research Lab Munitions Directorate have developed a system which incorporates the best of these capabilities into a single device. The 'NeuroSeek' device integrates these technologies into an IR focal plane array (FPA) which combines multicolor Midwave IR/Longwave IR radiometric response with on-focal plane 'smart' neuromorphic analog image processing. The readout and processing integrated circuit very large scale integration chip which was developed under this effort will be hybridized to a dual color detector array to produce the NeuroSeek FPA, which will have the capability to fuse multiple pixel-based sensor inputs directly on the focal plane. Great advantages are afforded by application of massively parallel processing algorithms to image data in the analog domain; the high speed and low power consumption of this device mimic operations performed in the human retina.
NASA Astrophysics Data System (ADS)
Gambicorti, L.; Piazza, D.; Gerber, M.; Pommerol, A.; Roloff, V.; Ziethe, R.; Zimmermann, C.; Da Deppo, V.; Cremonese, G.; Ficai Veltroni, I.; Marinai, M.; Di Carmine, E.; Bauer, T.; Moebius, P.; Thomas, N.
2016-08-01
A new technique based on photolithographic processes of thin-film optical pass band coatings on a monolithic substrate has been applied to the filters of the Focal Plane Assembly (FPA) of the Colour and Stereo Surface Imaging System (CaSSIS) that will fly onboard of the ExoMars Trace Gas Orbiter to be launched in March 2016 by ESA. The FPA including is one of the spare components of the Simbio-Sys instrument of the Italian Space Agency (ASI) that will fly on ESA's Bepi Colombo mission to Mercury. The detector, developed by Raytheon Vision Systems, is a 2kx2k hybrid Si-PIN array with a 10 μm pixel. The detector is housed within a block and has filters deposited directly on the entrance window. The window is a 1 mm thick monolithic plate of fused silica. The Filter Strip Assembly (FSA) is produced by Optics Balzers Jena GmbH and integrated on the focal plane by Leonardo-Finmeccanica SpA (under TAS-I responsibility). It is based on dielectric multilayer interference coatings, 4 colour bands selected with average in-band transmission greater than 95 percent within wavelength range (400-1100 nm), giving multispectral images on the same detector and thus allows CaSSIS to operate in push-frame mode. The Field of View (FOV) of each colour band on the detector is surrounded by a mask of low reflective chromium (LRC), which also provides with the straylight suppression required (an out-of-band transmission of less than 10-5/nm). The mask has been shown to deal effectively with cross-talk from multiple reflections between the detector surface and the filter. This paper shows the manufacturing and optical properties of the FSA filters and the FPA preliminary on-ground calibration results.
Li, Weide; Kong, Demeng; Wu, Jinran
2017-01-01
Air pollution in China is becoming more serious especially for the particular matter (PM) because of rapid economic growth and fast expansion of urbanization. To solve the growing environment problems, daily PM2.5 and PM10 concentration data form January 1, 2015, to August 23, 2016, in Kunming and Yuxi (two important cities in Yunnan Province, China) are used to present a new hybrid model CI-FPA-SVM to forecast air PM2.5 and PM10 concentration in this paper. The proposed model involves two parts. Firstly, due to its deficiency to assess the possible correlation between different variables, the cointegration theory is introduced to get the input-output relationship and then obtain the nonlinear dynamical system with support vector machine (SVM), in which the parameters c and g are optimized by flower pollination algorithm (FPA). Six benchmark models, including FPA-SVM, CI-SVM, CI-GA-SVM, CI-PSO-SVM, CI-FPA-NN, and multiple linear regression model, are considered to verify the superiority of the proposed hybrid model. The empirical study results demonstrate that the proposed model CI-FPA-SVM is remarkably superior to all considered benchmark models for its high prediction accuracy, and the application of the model for forecasting can give effective monitoring and management of further air quality.
Wu, Jinran
2017-01-01
Air pollution in China is becoming more serious especially for the particular matter (PM) because of rapid economic growth and fast expansion of urbanization. To solve the growing environment problems, daily PM2.5 and PM10 concentration data form January 1, 2015, to August 23, 2016, in Kunming and Yuxi (two important cities in Yunnan Province, China) are used to present a new hybrid model CI-FPA-SVM to forecast air PM2.5 and PM10 concentration in this paper. The proposed model involves two parts. Firstly, due to its deficiency to assess the possible correlation between different variables, the cointegration theory is introduced to get the input-output relationship and then obtain the nonlinear dynamical system with support vector machine (SVM), in which the parameters c and g are optimized by flower pollination algorithm (FPA). Six benchmark models, including FPA-SVM, CI-SVM, CI-GA-SVM, CI-PSO-SVM, CI-FPA-NN, and multiple linear regression model, are considered to verify the superiority of the proposed hybrid model. The empirical study results demonstrate that the proposed model CI-FPA-SVM is remarkably superior to all considered benchmark models for its high prediction accuracy, and the application of the model for forecasting can give effective monitoring and management of further air quality. PMID:28932237
SABER on Orbit Performance Evaluation and Lessons Learned
NASA Astrophysics Data System (ADS)
Jensen, Scott M.; Batty, J. Clair
2004-06-01
The Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) instrument, launched into orbit December 7, 2001, utilized a miniature pulse-tube cryocooler to maintain the SABER focal plane assembly (FPA) at 75 K. The limited cooling capacity of the cryocooler necessitated the development of a new never before flown Fiber Support Technology (FiST) for supporting and thermally isolating the FPA. A very precise predictive thermal modeling effort to ensure successful operation was also needed due to the very small capacity margin of the cryocooler. A high performance thermal link that minimized the temperature difference between the FPA and the cryocooler cold block and also the mechanical dynamic loading on the fragile pulse tube was developed and space qualified. This paper presents a comparison of the thermal modeling predictions with on orbit measurements, and discusses the lessons learned concerning long term performance issues of thermal isolation systems which utilize cryocoolers for cooling focal plane assemblies (FPA's). The effect of ice deposition on the thermal blankets and other FPA cooled structures, as well as the lessons learned in dealing with this ice deposition, will also be presented.
Confocal Raman spectroscopy and AFM for evaluation of sidewalls in type II superlattice FPAs
NASA Astrophysics Data System (ADS)
Rotter, T. J.; Busani, T.; Rathi, P.; Jaeckel, F.; Reyes, P. A.; Malloy, K. J.; Ukhanov, A. A.; Plis, E.; Krishna, S.; Jaime-Vasquez, M.; Baril, N. F.; Benson, J. D.; Tenne, D. A.
2015-06-01
We propose to utilize confocal Raman spectroscopy combined with high resolution atomic force microscopy (AFM) for nondestructive characterisation of the sidewalls of etched and passivated small pixel (24 μm×24 μm) focal plane arrays (FPA) fabricated using LW/LWIR InAs/GaSb type-II strained layer superlattice (T2SL) detector material. Special high aspect ratio Si and GaAs AFM probes, with tip length of 13 μm and tip aperture less than 7°, allow characterisation of the sidewall morphology. Confocal microscopy enables imaging of the sidewall profile through optical sectioning. Raman spectra measured on etched T2SL FPA single pixels enable us to quantify the non-uniformity of the mesa delineation process.
Desyatova, Anastasia; MacTaggart, Jason; Poulson, William; Deegan, Paul; Lomneth, Carol; Sandip, Anjali; Kamenskiy, Alexey
2017-06-01
Open and endovascular treatments for peripheral arterial disease are notorious for high failure rates. Severe mechanical deformations experienced by the femoropopliteal artery (FPA) during limb flexion and interactions between the artery and repair materials play important roles and may contribute to poor clinical outcomes. Computational modeling can help optimize FPA repair, but these simulations heavily depend on the choice of constitutive model describing the arterial behavior. In this study finite element model of the FPA in the standing (straight) and gardening (acutely bent) postures was built using computed tomography data, longitudinal pre-stretch and biaxially determined mechanical properties. Springs and dashpots were used to represent surrounding tissue forces associated with limb flexion-induced deformations. These forces were then used with age-specific longitudinal pre-stretch and mechanical properties to obtain deformed FPA configurations for seven age groups. Four commonly used invariant-based constitutive models were compared to determine the accuracy of capturing deformations and stresses in each age group. The four-fiber FPA model most accurately portrayed arterial behavior in all ages, but in subjects younger than 40 years, the performance of all constitutive formulations was similar. In older subjects, Demiray (Delfino) and classic two-fiber Holzapfel-Gasser-Ogden formulations were better than the Neo-Hookean model for predicting deformations due to limb flexion, but both significantly overestimated principal stresses compared to the FPA or Neo-Hookean models.
Sánchez-Villalobos, Alfredo; Urdaneta-Fernández, Margelys; Rubio-Fuenmayor, Elí; Molero-Saras, Gladys; Luzardo-Charris, Carlos; Corona-Mengual, Carlos
2011-03-01
In order to show the development and scope of a serological analysis method based on fluorescence polarization assay (FPA) from a drop of blood obtained by the capillary technique, a Brucella antibody assay was performed on a group of 321 high-risk workers. The results were compared with data from the analysis of blood serum by FPA and a competitive enzyme immunoassay (ELISA-c). The number of concordance was 318 (99.06%), and discordant 3 (0.93%), which were negative in serum by fluorescence polarization (FPAs) and ELISA-c, but positive with capillary FPA (FPAc). The comparative results FPAc were: sensitivity 100%; specificity: 99.05%; positive predictive value 66.67%; negative predictive value 100.0%; false positive rate: 0.95%; false negative rate: 0%; accuracy: 98.0%; odds ratio: 203.00. The youden J for both FPA methods was 0.667. The identification was considered reliable and the correlation of both procedures, FPA and ELISA-c, was no statistically different (P > 0.05%), which allows to highly recommend the study implementation of human brucellosis with capillary blood as a preliminary method.
Preparation of folate-modified pullulan acetate nanoparticles for tumor-targeted drug delivery.
Zhang, Hui-zhu; Li, Xue-min; Gao, Fu-ping; Liu, Ling-rong; Zhou, Zhi-min; Zhang, Qi-qing
2010-01-01
The purpose of this work was to develop a novel nano-carrier with targeting property to tumor. In this study, pullulan acetate (PA) was synthesized by the acetylation of pullulan to simplify the preparation technique of nanoparticles. Folic acid (FA) was conjugated to PA in order to improve the cancer-targeting activity. The products were characterized by proton nuclear magnetic resonance (¹H NMR) spectroscopy. Epirubicin-loaded nanoparticles were prepared by a solvent diffusion method. The loading efficiencies and EPI content increased with the amount of triethylamine (TEA) increasing in some degree. FPA nanoparticles could incorporate more epirubicin than PA nanoparticles. The folate-modified PA nanoparticles (FPA/EPI NPs) exhibited faster drug release than PA nanoparticles (PA/EPI NPs) in vitro. Confocal image analysis and flow cytometry test revealed that FPA/EPI NPs exhibited a greater extent of cellular uptake than PA/EPI NPs against KB cells over-expressing folate receptors on the surface. FPA/EPI NPs also showed higher cytotoxicity than PA/EPI NPs. The cytotoxic effect of FPA/EPI NPs to KB cells was inhibited by an excess amount of folic acid, suggesting that the binding and/or uptake were mediated by the folate receptor.
Read-noise characterization of focal plane array detectors via mean-variance analysis.
Sperline, R P; Knight, A K; Gresham, C A; Koppenaal, D W; Hieftje, G M; Denton, M B
2005-11-01
Mean-variance analysis is described as a method for characterization of the read-noise and gain of focal plane array (FPA) detectors, including charge-coupled devices (CCDs), charge-injection devices (CIDs), and complementary metal-oxide-semiconductor (CMOS) multiplexers (infrared arrays). Practical FPA detector characterization is outlined. The nondestructive readout capability available in some CIDs and FPA devices is discussed as a means for signal-to-noise ratio improvement. Derivations of the equations are fully presented to unify understanding of this method by the spectroscopic community.
ICC Type II large-format FPA detector assemblies
NASA Astrophysics Data System (ADS)
Clynne, Thomas H.; Powers, Thomas P.
1997-08-01
ICC presents a new addition to their integrated detector assembly product line with the announcement of their type II large format staring class FPA units. A result of internally funded research and development, the ICC type II detector assembly can accommodate all existing large format staring class PtSi, InSb and MCT focal planes, up to 640 by 480. Proprietary methodologies completely eliminate all FPA stresses to allow for maximum FPA survivability. Standard optical and cryocooler interfaces allow for the use of BEI, AEG, TI SADA Hughes/Magnavox and Joule Thompson coolers. This unit has been qualified to the current SADA II thermal environmental specifications and was tailored around ICC's worldwide industry standard type IV product. Assembled in a real world flexible manufacturing environment, this unit features a wide degree of adaptability and can be easily modified to a user's specifications via standard options and add-ons that include optical interfaces, electrical interfaces and window/filter material selections.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Interior (1094-0001), by telefax at (202) 395-5806 or via email to [email protected] . Also, please... information covered by 1094-0001. Under FPA section 33, the Secretary of the Department involved must accept... 45; 50 CFR Part 221; the Alternatives Process in Hydropower Licensing. OMB Control Number: 1094-0001...
Constitutive description of human femoropopliteal artery aging.
Kamenskiy, Alexey; Seas, Andreas; Deegan, Paul; Poulson, William; Anttila, Eric; Sim, Sylvie; Desyatova, Anastasia; MacTaggart, Jason
2017-04-01
Femoropopliteal artery (FPA) mechanics play a paramount role in pathophysiology and the artery's response to therapeutic interventions, but data on FPA mechanical properties are scarce. Our goal was to characterize human FPAs over a wide population to derive a constitutive description of FPA aging to be used for computational modeling. Fresh human FPA specimens ([Formula: see text]) were obtained from [Formula: see text] predominantly male (80 %) donors 54±15 years old (range 13-82 years). Morphometric characteristics including radius, wall thickness, opening angle, and longitudinal pre-stretch were recorded. Arteries were subjected to multi-ratio planar biaxial extension to determine constitutive parameters for an invariant-based model accounting for the passive contributions of ground substance, elastin, collagen, and smooth muscle. Nonparametric bootstrapping was used to determine unique sets of material parameters that were used to derive age-group-specific characteristics. Physiologic stress-stretch state was calculated to capture changes with aging. Morphometric and constitutive parameters were derived for seven age groups. Vessel radius, wall thickness, and circumferential opening angle increased with aging, while longitudinal pre-stretch decreased ([Formula: see text]). Age-group-specific constitutive parameters portrayed orthotropic FPA stiffening, especially in the longitudinal direction. Structural changes in artery wall elastin were associated with reduction of physiologic longitudinal and circumferential stretches and stresses with age. These data and the constitutive description of FPA aging shed new light on our understanding of peripheral arterial disease pathophysiology and arterial aging. Application of this knowledge might improve patient selection for specific treatment modalities in personalized, precision medicine algorithms and could assist in device development for treatment of peripheral artery disease.
Stereo Imaging Miniature Endoscope with Single Imaging Chip and Conjugated Multi-Bandpass Filters
NASA Technical Reports Server (NTRS)
Shahinian, Hrayr Karnig (Inventor); Bae, Youngsam (Inventor); White, Victor E. (Inventor); Shcheglov, Kirill V. (Inventor); Manohara, Harish M. (Inventor); Kowalczyk, Robert S. (Inventor)
2018-01-01
A dual objective endoscope for insertion into a cavity of a body for providing a stereoscopic image of a region of interest inside of the body including an imaging device at the distal end for obtaining optical images of the region of interest (ROI), and processing the optical images for forming video signals for wired and/or wireless transmission and display of 3D images on a rendering device. The imaging device includes a focal plane detector array (FPA) for obtaining the optical images of the ROI, and processing circuits behind the FPA. The processing circuits convert the optical images into the video signals. The imaging device includes right and left pupil for receiving a right and left images through a right and left conjugated multi-band pass filters. Illuminators illuminate the ROI through a multi-band pass filter having three right and three left pass bands that are matched to the right and left conjugated multi-band pass filters. A full color image is collected after three or six sequential illuminations with the red, green and blue lights.
MTF measurements of a type-II superlattice infrared focal plane array sealed in a cryocooler.
Nghiem, Jean; Jaeck, Julien; Primot, Jerome; Coudrain, Christophe; Derelle, Sophie; Huard, Edouard; Caes, Marcel; Bernhardt, Sylvie; Haidar, Riad; Christol, Philippe; Ribet-Mohamed, Isabelle
2018-04-16
In operational electro-optical systems, infrared focal plane arrays (IR FPA) are integrated in cryocoolers which induce vibrations that may strongly affect their modulation transfer function (MTF). In this paper, we present the MTF measurement of an IR FPA sealed in its cryocooler. The method we use to measure the MTF decorrelates operational constraints and the technological limitations of the IR FPA. The bench is based on the diffraction properties of a continuously self imaging grating (CSIG). The 26 µm pixel size extracted from the MTF measurement is in good agreement with the expected value.
The influence of sorbitol on the production of cellulases and xylanases in an airlift bioreactor.
Ritter, Carla Eliana Todero; Fontana, Roselei Claudete; Camassola, Marli; da Silveira, Maurício Moura; Dillon, Aldo José Pinheiro
2013-11-01
The production of cellulases and xylanases by Penicillium echinulatum in an airlift bioreactor was evaluated. In batch production, we tested media with isolated or associated cellulose and sorbitol. In fed-batch production, we tested cellulose addition at two different times, 30 h and 48 h. Higher liquid circulation velocities in the downcomer were observed in sorbitol 10 g L(-1) medium. In batch production, higher FPA (filter paper activity) and endoglucanase activities were obtained with cellulose (7.5 g L(-1)) and sorbitol (2.5 g L(-1)), 1.0 U mL(-1) (120 h) and 6.4 U m L(-1) (100 h), respectively. For xylanases, the best production condition was cellulose 10 g L(-1), which achieved 5.5 U mL(-1) in 64 h. The fed-batch process was favorable for obtaining xylanases, but not for FPA and endoglucanases, suggesting that in the case of cellulases, the inducer must be added early in the process. Copyright © 2013 Elsevier Ltd. All rights reserved.
Measurement of filter paper activities of cellulase with microplate-based assay.
Yu, Xiaoxiao; Liu, Yan; Cui, Yuxiao; Cheng, Qiyue; Zhang, Zaixiao; Lu, Jia Hui; Meng, Qingfan; Teng, Lirong; Ren, Xiaodong
2016-01-01
It is always a challenge to determine the total cellulase activity efficiently without reducing accuracy. The most common total cellulase activity assay is the filter paper assay (FPA) established by the International Union of Pure and Applied Chemistry (IUPAC). A new procedure to measure the FPA with microplate-based assay was studied in this work, which followed the main idea of IUPAC to dilute cellulase preparation to get fixed glucose release. FPAs of six cellulase preparations were determined with the microplate-based assay. It is shown that FPAs of cellulase Youtell, RCconc, R-10, Lerkam, Yishui and Sinopharm were 67.9, 46.0, 46.1, 27.4, 7.6 and 8.0 IU/ml respectively. There was no significant difference at the 95% confidence level between the FPA determined with IUPAC and the microplate-based assay. It could be concluded that the FPA could be determined by the microplate-based assay with the same accuracy and much more efficiency compared with that by IUPAC.
Measurement of filter paper activities of cellulase with microplate-based assay
Yu, Xiaoxiao; Liu, Yan; Cui, Yuxiao; Cheng, Qiyue; Zhang, Zaixiao; Lu, Jia Hui; Meng, Qingfan; Teng, Lirong; Ren, Xiaodong
2015-01-01
It is always a challenge to determine the total cellulase activity efficiently without reducing accuracy. The most common total cellulase activity assay is the filter paper assay (FPA) established by the International Union of Pure and Applied Chemistry (IUPAC). A new procedure to measure the FPA with microplate-based assay was studied in this work, which followed the main idea of IUPAC to dilute cellulase preparation to get fixed glucose release. FPAs of six cellulase preparations were determined with the microplate-based assay. It is shown that FPAs of cellulase Youtell, RCconc, R-10, Lerkam, Yishui and Sinopharm were 67.9, 46.0, 46.1, 27.4, 7.6 and 8.0 IU/ml respectively. There was no significant difference at the 95% confidence level between the FPA determined with IUPAC and the microplate-based assay. It could be concluded that the FPA could be determined by the microplate-based assay with the same accuracy and much more efficiency compared with that by IUPAC. PMID:26858572
French, Rebecca S; Cowan, Frances M; Wellings, Kaye; Dowie, Jack
2014-04-01
My Contraception Tool (MCT) applies the principles of multi-criteria decision analysis to the choice of contraceptive method. Its purpose is to make the decision-making process transparent to the user and to suggest a method to them based on their own preferences. The contraceptive option that emerges as optimal from the analysis takes account of the probability of a range of outcomes and the relative weight ascribed to them by the user. The development of MCT was a collaborative project between London School of Hygiene & Tropical Medicine, Brook, FPA and Maldaba Ltd. MCT is available online via the Brook and FPA websites. In this article we describe MCT's development and how it works. Further work is needed to assess the impact it has on decision quality and contraceptive behaviour.
Li, Yantao; Hu, Weida; Ye, Zhenhua; Chen, Yiyu; Chen, Xiaoshuang; Lu, Wei
2017-04-01
Mercury cadmium telluride is the standard material to fabricate high-performance infrared focal plane array (FPA) detectors. However, etch-induced damage is a serious obstacle for realizing highly uniform and damage-free FPA detectors. In this Letter, the high signal-to-noise ratio and high spatial resolution scanning photocurrent microscopy (SPCM) is used to characterize the dry etch-induced inversion layer of vacancy-doped p-type Hg1-xCdxTe (x=0.22) material under different etching temperatures. It is found that the peak-to-peak magnitude of the SPCM profile decreases with a decrease in etching temperature, showing direct proof of controlling dry etch-induced type conversion. Our work paves the way toward seeking optimal etching processes in large-scale infrared FPAs.
2014-10-31
Hole .......................................................4 2. SOHO EIT Image with Coronal Holes and FPA Vector...Diagram of CME Deflection by a Coronal Hole Figure 2: SOHO EIT Image with Coronal Holes and FPA Vector Approved for public release; distribution
Frade, A; Vilar, D
1991-05-01
The article on sex education in Portugal covers background, the educational system, the clashes of the 1960's over sex education, the Committee for the Study of Sexuality and Education (CSSE), the policies, politics and social movements during the period 1974 - 1984, the discussions in Parliament, the 1988 Reform of the Educational System, the Family Planning Association (FPA) and sex education, and the future role of the FPA. It was not until the institution of the multiparity parliamentary system in 1974 that discussing social and political changes was possible, culminating in 1984 with new legislation on abortion, family planning, and sex education. School reform came in 1987/8 with the Ministry of Education primarily responsible for curricula. The 1960's brought with it the influence of the Catholic Church. Change came in the form of progressivism among Catholics who replaced dogma with dialogue and listening. Sex education was considered as preparation for marriage, but masturbation, contraception, and prostitution were also discussed. In addition, the founder of FPA chaired the CSSE in 1971 and opened up debate on sex issues and drafted a bill to establish co-education in Portuguese schools. The revolution of 1974 brought an end to censorship and brought forth a policy of developing family planning. Changed in the Family Code gave women greater equality. UNFPA supported teacher training in non-sexist education. With human reproduction included in the natural sciences, there was still no school sex education policy and contraception was only sometimes represented in the biology curriculum. The focus of FPA was on contraception and abortion. Finally in the 1980's, the first sex education programs were developed for out-of-school youth. Even though in the 1970's there were leftists groups promoting sex education, it took leftist parliamentary power to get legislation on sex education in the schools adopted. The Ministry of Education however was pressured by the Catholic Church. As in 1973, committees were formed but no action was taken. Sex education activity increased nonetheless - the first FPA document on school education prepared. In 1986 Personal and Social Education was approved by parliament providing an alternative (due to the Catholic Church) to Religious Education, but even with FPA support documents, the implementation did not begin until the end of 1990. In brief the FPA's emphasis was on the body, sexuality, sex and interpersonal relationships, and sexual reproduction. The role of FPA continues at the grass roots level in stimulating discussion; cooperating with schools, students and parents; and acting as a resource center.
Limb flexion-induced twist and associated intramural stresses in the human femoropopliteal artery.
Desyatova, Anastasia; Poulson, William; Deegan, Paul; Lomneth, Carol; Seas, Andreas; Maleckis, Kaspars; MacTaggart, Jason; Kamenskiy, Alexey
2017-03-01
High failure rates of femoropopliteal artery (FPA) interventions are often attributed to severe mechanical deformations that occur with limb movement. Torsion of the FPA likely plays a significant role, but is poorly characterized and the associated intramural stresses are currently unknown. FPA torsion in the walking, sitting and gardening postures was characterized in n = 28 in situ FPAs using intra-arterial markers. Principal mechanical stresses and strains were quantified in the superficial femoral artery (SFA), adductor hiatus segment (AH) and the popliteal artery (PA) using analytical modelling. The FPA experienced significant torsion during limb flexion that was most severe in the gardening posture. The associated mechanical stresses were non-uniformly distributed along the length of the artery, increasing distally and achieving maximum values in the PA. Maximum twist in the SFA ranged 10-13° cm -1 , at the AH 8-16° cm -1 , and in the PA 14-26° cm -1 in the walking, sitting and gardening postures. Maximum principal stresses were 30-35 kPa in the SFA, 27-37 kPa at the AH and 39-43 kPa in the PA. Understanding torsional deformations and intramural stresses in the FPA can assist with device selection for peripheral arterial disease interventions and may help guide the development of devices with improved characteristics. © 2017 The Author(s).
Innovative compact focal plane array for wide field vis and ir orbiting telescopes
NASA Astrophysics Data System (ADS)
Hugot, Emmanuel; Vives, Sébastien; Ferrari, Marc; Gaeremynck, Yann; Jahn, Wilfried
2017-11-01
The future generation of high angular resolution space telescopes will require breakthrough technologies to combine large diameters and large focal plane arrays with compactness and lightweight mirrors and structures. Considering the allocated volume medium-size launchers, short focal lengths are mandatory, implying complex optical relays to obtain diffraction limited images on large focal planes. In this paper we present preliminary studies to obtain compact focal plane arrays (FPA) for earth observations on low earth orbits at high angular resolution. Based on the principle of image slicers, we present an optical concept to arrange a 1D FPA into a 2D FPA, allowing the use of 2D detector matrices. This solution is particularly attractive for IR imaging requiring a cryostat, which volume could be considerably reduced as well as the relay optics complexity. Enabling the use of 2D matrices for such an application offers new possibilities. Recent developments on curved FPA allows optimization without concerns on the field curvature. This innovative approach also reduces the complexity of the telescope optical combination, specifically for fast telescopes. This paper will describe the concept and optical design of an F/5 - 1.5m telescope equipped with such a FPA, the performances and the impact on the system with a comparison with an equivalent 1.5m wide field Korsch telescope.
Liu, Liya; Zhao, Mengli; Liu, Xingxun; Zhong, Kui; Tong, Litao; Zhou, Xianrong; Zhou, Sumei
2016-08-01
The majority of phenolic acids in wheat bran are bound to the cell walls. Hence, a high proportion of phenolic acids cannot be extracted with conventional extraction methods. This study aimed to investigate the efficiency of steam explosion pre-treatment in increasing the extractability of phenolic compounds from wheat bran. Bound phenolic acids (BPA) can be released by steam explosion-assisted extraction. Within the experimental range, soluble free phenolic acids (FPA) and soluble conjugated phenolic acids (CPA) increased gradually with residence time and temperature. After steam explosion at 215 °C for 120 s, the total FPA and CPA reached 6671.8 and 2578.6 µg GAE g(-1) bran, respectively, which was about 39-fold and seven-fold higher than that of the untreated sample. Ferulic acid, the major individual phenolic acids in bran, increased from 55.7 to 586.3 µg g(-1) for FPA, and from 44.9 to 1108.4 µg g(-1) for CPA. The antioxidant properties of FPA and CPA extracts were significantly improved after treated. Correlation analysis indicated that the antioxidant capacity was in close relationship with phenolic content in FPA and CPA. Steam explosion pre-treatment could be effectively used to release of BPA and enhance the antioxidant capacity of wheat bran. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
Compact Focal Plane Assembly for Planetary Science
NASA Technical Reports Server (NTRS)
Brown, Ari; Aslam, Shahid; Huang, Wei-Chung; Steptoe-Jackson, Rosalind
2013-01-01
A compact radiometric focal plane assembly (FPA) has been designed in which the filters are individually co-registered over compact thermopile pixels. This allows for construction of an ultralightweight and compact radiometric instrument. The FPA also incorporates micromachined baffles in order to mitigate crosstalk and low-pass filter windows in order to eliminate high-frequency radiation. Compact metal mesh bandpass filters were fabricated for the far infrared (FIR) spectral range (17 to 100 microns), a game-changing technology for future planetary FIR instruments. This fabrication approach allows the dimensions of individual metal mesh filters to be tailored with better than 10- micron precision. In contrast, conventional compact filters employed in recent missions and in near-term instruments consist of large filter sheets manually cut into much smaller pieces, which is a much less precise and much more labor-intensive, expensive, and difficult process. Filter performance was validated by integrating them with thermopile arrays. Demonstration of the FPA will require the integration of two technologies. The first technology is compact, lightweight, robust against cryogenic thermal cycling, and radiation-hard micromachined bandpass filters. They consist of a copper mesh supported on a deep reactive ion-etched silicon frame. This design architecture is advantageous when constructing a lightweight and compact instrument because (1) the frame acts like a jig and facilitates filter integration with the FPA, (2) the frame can be designed so as to maximize the FPA field of view, (3) the frame can be simultaneously used as a baffle for mitigating crosstalk, and (4) micron-scale alignment features can be patterned so as to permit high-precision filter stacking and, consequently, increase the filter bandwidth and sharpen the out-of-band rolloff. The second technology consists of leveraging, from another project, compact and lightweight Bi0.87Sb0.13/Sb arrayed thermopiles. These detectors consist of 30-layer thermopiles deposited in series upon a silicon nitride membrane. At 300 K, the thermopile arrays are highly linear over many orders of magnitude of incident IR power, and have a reported specific detectivity that exceeds the requirements imposed on future mission concepts. The bandpass filter array board is integrated with a thermopile array board by mounting both boards on a machined aluminum jig.
NASA Astrophysics Data System (ADS)
Garcilazo, H.; Valcarce, A.; Vijande, J.
2017-07-01
Using local central Yukawa-type Malfliet-Tjon interactions reproducing the low-energy parameters and phase shifts of the nn system, and the latest updates of the nΛ and ΛΛ Nijmegen ESC08c potentials, we study the possible existence of a bound state. Our results indicate that the is unbound, being just above threshold. We discuss the role played by the 1 S 0 nn repulsive term of the Yukawa-type Malfliet-Tjon interaction. Supported by COFAA-IPN (México), Ministerio de Economía, Industria y Competitividad and EU FEDER (FPA2013-47443, FPA2015-69714-REDT, FPA2016-77177), Junta de Castilla y León (SA041U16) and Generalitat Valenciana PrometeoII/2014/066
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-13
...--Criteria for Qualifying Conduit Hydropower Facility Satisfies (Y/ Statutory provision Description N) FPA 30(a)(3)(A), as amended by The conduit the Y HREA. facility uses is a tunnel, canal, pipeline, aqueduct... agricultural, municipal, or industrial consumption and not primarily for the generation of electricity. FPA 30...
Chemical imaging of cotton fibers using an infrared microscope and a focal-plane array detector
USDA-ARS?s Scientific Manuscript database
In this presentation, the chemical imaging of cotton fibers with an infrared microscope and a Focal-Plane Array (FPA) detector will be discussed. Infrared spectroscopy can provide us with information on the structure and quality of cotton fibers. In addition, FPA detectors allow for simultaneous spe...
Evaluation of Primary Binding Assays for Presumptive Serodiagnosis of Swine Brucellosis in Argentina
Paulo, P. Silva; Vigliocco, A. M.; Ramondino, R. F.; Marticorena, D.; Bissi, E.; Briones, G.; Gorchs, C.; Gall, D.; Nielsen, K.
2000-01-01
An indirect enzyme-linked immunosorbent assay (IELISA), a competitive ELISA (CELISA), and a fluorescence polarization assay (FPA) for the presumptive serological diagnosis of swine brucellosis were evaluated using two populations of swine sera: sera from brucellosis-free Canadian herds and sera from Argentina selected based on positive reactions in the buffered antigen plate agglutination test (BPAT) and the 2-mercaptoethanol (2-ME) test. In addition, sera from adult swine from which Brucella suis was isolated at least once for each farm of origin were evaluated. The IELISA, CELISA, and FPA specificity values were 99.9, 99.5, and 98.3%, respectively, and the IELISA, CELISA, and FPA sensitivity values relative to the BPAT and the 2-ME test were 98.9, 96.6, and 93.8%, respectively. Actual sensitivity was assessed by using 37 sera from individual pigs from which B. suis was cultured, and the values obtained were as follows: BPAT, 86.5%; 2-ME test, 81.1%; IELISA, 86.5%; CELISA, 78.5%; and FPA, 80.0%. PMID:10973463
Corrugated Quantum Well Infrared Photodetector Focal Plane Array Test Results
NASA Technical Reports Server (NTRS)
Goldberg, A.; Choi, K. K.; Das, N. C.; La, A.; Jhabvala, M.
1999-01-01
The corrugated quantum-well infrared photodetector (C-QWIP) uses total internal reflection to couple normal incident light into the optically active quantum wells. The coupling efficiency has been shown to be relatively independent of the pixel size and wavelength thus making the C-QWIP a candidate for detectors over the entire infrared spectrum. The broadband coupling efficiency of the C-QWIP makes it an ideal candidate for multiwavelength detectors. We fabricated and tested C-QWIP focal plane arrays (FPAs) with cutoff wavelengths of 11.2 and 16.2 micrometers. Each FPA has 256 x 256 pixels that are bump-bonded to a direct injection readout circuit. Both FPAs provided infrared imagery with good aesthetic attributes. For the 11.2-micrometers FPA, background-limited performance (BLIP) was observed at 60 K with f/3 optics. For the 16.2-micrometers FPA, BLIP was observed at 38 K. Besides the reduction of dark current in C-QWIP structures, the measured internal quantum efficiency (eta) remains to be high. The values for responsivity and quantum efficiency obtained from the FPA results agree well with those measured for single devices.
Yu, Jianwei; An, Wei; Cao, Nan; Yang, Min; Gu, Junong; Zhang, Dong; Lu, Ning
2014-07-01
Taste and odor (T/O) in drinking water often cause consumer complaints and are thus regulated in many countries. However, people in different regions may exhibit different sensitivities toward T/O. This study proposed a method to determine the regional drinking water odorant regulation goals (ORGs) based on the odor sensitivity distribution of the local population. The distribution of odor sensitivity to 2-methylisoborneol (2-MIB) by the local population in Beijing, China was revealed by using a normal distribution function/model to describe the odor complaint response to a 2-MIB episode in 2005, and a 2-MIB concentration of 12.9 ng/L and FPA (flavor profile analysis) intensity of 2.5 was found to be the critical point to cause odor complaints. Thus the Beijing ORG for 2-MIB was determined to be 12.9 ng/L. Based on the assumption that the local FPA panel can represent the local population in terms of sensitivity to odor, and that the critical FPA intensity causing odor complaints was 2.5, this study tried to determine the ORGs for seven other cities of China by performing FPA tests using an FPA panel from the corresponding city. ORG values between 12.9 and 31.6 ng/L were determined, showing that a unified ORG may not be suitable for drinking water odor regulations. This study presents a novel approach for setting drinking water odor regulations. Copyright © 2014. Published by Elsevier B.V.
Compact high-efficiency linear cryocooler in single-piston moving magnet design for HOT detectors
NASA Astrophysics Data System (ADS)
Rühlich, I.; Mai, M.; Rosenhagen, C.; Withopf, A.; Zehner, S.
2012-06-01
State of the art Mid Wave IR-technology has the potential to rise the FPA temperature from 77K to 130-150K (High Operation Temperature, HOT). Using a HOT FPA will significantly lower SWaP and keep those parameters finally dominated by the employed cryocooler. Therefore, compact high performance cryocoolers are mandatory. AIM has developed the SX040 cooler, optimized for FPA temperatures of about 95K (presented at SPIE 2010). The SX040 cooler incorporates a high efficient dual piston driving mechanism resulting in a very compact compressor of less than 100mm length. Higher compactness - especially shorter compressors - can be achieved by change from dual to single piston design. The new SX030 compressor has such a single piston Moving Magnet driving mechanism resulting in a compressor length of about 60mm. Common for SX040 and SX030 family is a Moving Magnet driving mechanism with coils placed outside the helium vessel. In combination with high performance plastics for the piston surfaces this design enables lifetimes in excess of 20,000h MTTF. Because of the higher FPA temperature and a higher operating frequency also a new displacer needs to be developed. Based on the existing 1/4" coldfinger interface AIM developed a new displacer optimized for an FPA temperature of 140K and above. This paper gives an overview on the development of this new compact single piston cryocooler. Technical details and performance data will be shown.
Carve, Megan; Coggan, Timothy L; Myers, Jackie H; Clarke, Bradley; Nugegoda, Dayanthi; Shimeta, Jeff
2018-02-01
The herbicide Fusilade Forte ® (FF) is widely applied in agricultural weed management and in the management of the invasive saltmarsh grass, Spartina anglica (ricegrass or cordgrass). FF (active ingredient fluazifop-P acid, FPA) is selective for poaceous grasses. Its primary mode of action is inhibition of the acetyl coenzyme-A carboxylase (ACCase) specific to this taxonomic group, and its secondary mode is by promotion of oxidative stress. FF is applied to S. anglica infestations in the intertidal zone, in proximity to seagrass meadows. Despite the potential for vital seagrass ecosystems to be exposed to FF, there is limited knowledge of any potential impacts. We investigated impacts of FPA on the endemic Australian seagrass, Zostera nigricaulis, measuring ACCase activity and parameters that reflect oxidative stress: photosynthetic performance, lipid peroxidation and photosynthetic pigment content. Seagrass was exposed to FF (0.01-10mgL -1 FPA and a control) for 7d, followed by a 7-d recovery in uncontaminated seawater. An enzyme assay demonstrated that FPA ≤10mgL -1 did not inhibit the activity of ACCase isolated from Z. nigricaulis, demonstrating that this seagrass is resistant to FF's primary mode of action. However, physiological impacts occurred following 7 days exposure to ≥0.1mgL -1 FPA, including up to a 72% reduction in photosynthetic pigment concentration. After 7-d recovery, photosynthetic pigment content improved in treatment plants; however, treated plants exhibited higher levels of lipid peroxidation. This study demonstrates that while Z. nigricaulis is resistant to FF's primary mode of action, significant physiological impacts occur following 7 days exposure to ≥0.1mgL -1 FPA. This study provides valuable information on the effects of FF on a non-target species that can better inform approaches to Spartina management in coastal seagrass ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.
Validating Phasing and Geometry of Large Focal Plane Arrays
NASA Technical Reports Server (NTRS)
Standley, Shaun P.; Gautier, Thomas N.; Caldwell, Douglas A.; Rabbette, Maura
2011-01-01
The Kepler Mission is designed to survey our region of the Milky Way galaxy to discover hundreds of Earth-sized and smaller planets in or near the habitable zone. The Kepler photometer is an array of 42 CCDs (charge-coupled devices) in the focal plane of a 95-cm Schmidt camera onboard the Kepler spacecraft. Each 50x25-mm CCD has 2,200 x 1,024 pixels. The CCDs accumulate photons and are read out every six seconds to prevent saturation. The data is integrated for 30 minutes, and then the pixel data is transferred to onboard storage. The data is subsequently encoded and transmitted to the ground. During End-to-End Information System (EEIS) testing of the Kepler Mission System (KMS), there was a need to verify that the pixels requested by the science team operationally were correctly collected, encoded, compressed, stored, and transmitted by the FS, and subsequently received, decoded, uncompressed, and displayed by the Ground Segment (GS) without the outputs of any CCD modules being flipped, mirrored, or otherwise corrupted during the extensive FS and GS processing. This would normally be done by projecting an image on the focal plane array (FPA), collecting the data in a flight-like way, and making a comparison between the original data and the data reconstructed by the science data system. Projecting a focused image onto the FPA through the telescope would normally involve using a collimator suspended over the telescope opening. There were several problems with this approach: the collimation equipment is elaborate and expensive; as conceived, it could only illuminate a limited section of the FPA (.25 percent) during a given test; the telescope cover would have to be deployed during testing to allow the image to be projected into the telescope; the equipment was bulky and difficult to situate in temperature-controlled environments; and given all the above, test setup, execution, and repeatability were significant concerns. Instead of using this complicated approach of projecting an optical image on the FPA, the Kepler project developed a method using known defect features in the CCDs to verify proper collection and reassembly of the pixels, thereby avoiding the costs and risks of the optical projection approach. The CCDs composing the Kepler FPA, as all CCDs, had minor defects. At ambient temperature, some pixels look far brighter than they should. These ghot h pixels have a higher rate of charge leakage than the others due to manufacturing variations. They are usually stable over time, and appear at temperatures above 5 oC. The hot pixels on the Kepler FPA were mapped before photometer assembly during module testing. Selected hot pixels were used as target gstars h for the purposes of EEIS testing. gDead h pixels are permanently off, producing a permanently black pixel. These can also be used if there is some illumination of the FPA. During EEIS testing, Dark Current Full Frame Images (FFIs) taken at room temperature were used to create the hot pixel maps for all 84 Kepler photometer CCD channels. Data from two separate nights were used to create two hot pixel maps per channel, which were cross-correlated to remove cosmic ray events which appear to be hot pixels. These hot pixel maps obtained during EEIS testing were compared to the maps made during module testing to verify that the end-to-end data flow was correct.
Aircraft Survivability: Susceptibility Reduction, Spring 2003
2003-01-01
approach to implementing the real-time nonuniformity correction (NUC) hardware. Packaging and size constraints would not prohibit the future...92 Hz MWIR #3 Imager 640x512 InSb FPA Band: 3µm–5µm Pixel size: 24µm Max frame rate: 92 Hz LWIR Imager 640x512 HgCdTe FPA Band: 3µm–5µm Pixel size
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-21
...--Criteria for Qualifying Conduit Hydropower Facility Satisfies (Y/ Statutory provision Description N) FPA 30(a)(3)(A), as amended by The conduit the Y HREA. facility uses is a tunnel, canal, pipeline, aqueduct... agricultural, municipal, or industrial consumption and not primarily for the generation of electricity. FPA 30...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... trade associations and other organizations representing the interests of government and/or cooperatively... section 201(f) provides in relevant part that [n]o provision in [Part II of the FPA] shall apply to, or be... very small number of electric cooperatives that are not described by FPA section 201(f). Petitioners...
640 x 480 MWIR and LWIR camera system developments
NASA Astrophysics Data System (ADS)
Tower, John R.; Villani, Thomas S.; Esposito, Benjamin J.; Gilmartin, Harvey R.; Levine, Peter A.; Coyle, Peter J.; Davis, Timothy J.; Shallcross, Frank V.; Sauer, Donald J.; Meyerhofer, Dietrich
1993-01-01
The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.
640 x 480 MWIR and LWIR camera system developments
NASA Astrophysics Data System (ADS)
Tower, J. R.; Villani, T. S.; Esposito, B. J.; Gilmartin, H. R.; Levine, P. A.; Coyle, P. J.; Davis, T. J.; Shallcross, F. V.; Sauer, D. J.; Meyerhofer, D.
The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.
[Blood coagulation and fibrinolysis in ischemic heart disease].
Sakamoto, T; Ogawa, H; Miyao, Y; Yasue, H
1994-01-01
Intracoronary thrombus formation has been thought to play an important role in the genesis of acute myocardial infarction an unstable angina. To examine whether the coagulation and fibrinolytic systems are altered in such ischemic heart diseases, the plasma levels of fibrinopeptide A (FPA) and plasminogen activator (PAI) were measured. The plasma level of FPA was increased in patients with variant angina as compared with those with stable exertional angina and there was a significant circadian variation in the plasma level of FPA in parallel with that of the frequency of the attacks with the peak level occurring from midnight to early morning in patients with variant angina. The plasma FPA level increased in patients with coronary spastic angina after the ischemic attack induced by hyperventilation. Furthermore, FPA was released into the coronary circulation after the anginal attack induced by intracoronary injection of acetylcholine. These findings suggest that the coronary artery spasm may induce thrombin generation and trigger thrombus formation in the coronary artery. On the other hand, the plasma level of PAI activity was higher in patients with unstable angina and coronary spastic angina than in those with stable exertional angina. Moreover, the PAI activity in patients with unstable angina decreased to the level in patients with stable exertional angina after the stabilization of their symptoms by drugs. Our findings suggest that the increased plasma PAI activity may reduce fibrinolytic activity and attenuate removal of the thrombus and may ultimately lead to acute myocardial infarction in some patients with unstable angina and coronary spastic angina.(ABSTRACT TRUNCATED AT 250 WORDS)
Landsat 9 OLI 2 focal plane subsystem: design, performance, and status
NASA Astrophysics Data System (ADS)
Malone, Kevin J.; Schrein, Ronald J.; Bradley, M. Scott; Irwin, Ronda; Berdanier, Barry; Donley, Eric
2017-09-01
The Landsat 9 mission will continue the legacy of Earth remote sensing that started in 1972. The Operational Land Imager 2 (OLI 2) is one of two instruments on the Landsat 9 satellite. The OLI 2 instrument is essentially a copy of the OLI instrument flying on Landsat 8. A key element of the OLI 2 instrument is the focal plane subsystem, or FPS, which consists of the focal plane array (FPA), the focal plane electronics (FPE) box, and low-thermal conductivity cables. This paper presents design details of the OLI 2 FPS. The FPA contains 14 critically-aligned focal plane modules (FPM). Each module contains 6 visible/near-IR (VNIR) detector arrays and three short-wave infrared (SWIR) arrays. A complex multi-spectral optical filter is contained in each module. Redundant pixels for each array provide exceptional operability. Spare detector modules from OLI were recharacterized after six years of storage. Radiometric test results are presented and compared with data recorded in 2010. Thermal, optical, mechanical and structural features of the FPA will be described. Special attention is paid to the thermal design of the FPA since thermal stability is crucial to ensuring low-noise and low-drift operation of the detectors which operate at -63°C. The OLI 2 FPE provides power, timing, and control to the focal plane modules. It also digitizes the video data and formats it for the solid-state recorder. Design improvements to the FPA-FPE cables will be discussed and characterization data will be presented. The paper will conclude with the status of the flight hardware assembly and testing.
A novel readout integrated circuit for ferroelectric FPA detector
NASA Astrophysics Data System (ADS)
Bai, Piji; Li, Lihua; Ji, Yulong; Zhang, Jia; Li, Min; Liang, Yan; Hu, Yanbo; Li, Songying
2017-11-01
Uncooled infrared detectors haves some advantages such as low cost light weight low power consumption, and superior reliability, compared with cryogenically cooled ones Ferroelectric uncooled focal plane array(FPA) are being developed for its AC response and its high reliability As a key part of the ferroelectric assembly the ROIC determines the performance of the assembly. A top-down design model for uncooled ferroelectric readout integrated circuit(ROIC) has been developed. Based on the optical thermal and electrical properties of the ferroelectric detector the RTIA readout integrated circuit is designed. The noise bandwidth of RTIA readout circuit has been developed and analyzed. A novel high gain amplifier, a high pass filter and a low pass filter circuits are designed on the ROIC. In order to improve the ferroelectric FPA package performance and decrease of package cost a temperature sensor is designed on the ROIC chip At last the novel RTIA ROIC is implemented on 0.6μm 2P3M CMOS silicon techniques. According to the experimental chip test results the temporal root mean square(RMS)noise voltage is about 1.4mV the sensitivity of the on chip temperature sensor is 0.6 mV/K from -40°C to 60°C the linearity performance of the ROIC chip is better than 99% Based on the 320×240 RTIA ROIC, a 320×240 infrared ferroelectric FPA is fabricated and tested. Test results shows that the 320×240 RTIA ROIC meets the demand of infrared ferroelectric FPA.
Polarization Sensitive QWIP Thermal Imager
2000-03-01
array (FPA) with peak responsivity in the long-wave infrared ( LWIR ) spectral band near 9 µm. Polarization-dependent responsivity is achieved by...demonstrated in various combinations: MWIR/ LWIR (using rectangular grid gratings), MWIR/MWIR, and LWIR / LWIR . The FPA described here was fabricated with a...CCA supports the nonuniformity correction, global gain and level control, failed pixel substitution, dynamic range reduction, BIT status and serial
A Hybrid, Large-Scale Wireless Sensor Network for Real-Time Acquisition and Tracking
2007-06-01
multicolor, Quantum Well Infrared Photodetector ( QWIP ), step-stare, large-format Focal Plane Array (FPA) is proposed and evaluated through performance...Photodetector ( QWIP ), step-stare, large-format Focal Plane Array (FPA) is proposed and evaluated through performance analysis. The thesis proposes...7 1. Multi-color IR Sensors - Operational Advantages ...........................8 2. Quantum-Well IR Photodetector ( QWIP
Strained-layer superlattice focal plane array having a planar structure
Kim, Jin K [Albuquerque, NM; Carroll, Malcolm S [Albuquerque, NM; Gin, Aaron [Albuquerque, NM; Marsh, Phillip F [Lowell, MA; Young, Erik W [Albuquerque, NM; Cich, Michael J [Albuquerque, NM
2010-07-13
An infrared focal plane array (FPA) is disclosed which utilizes a strained-layer superlattice (SLS) formed of alternating layers of InAs and In.sub.xGa.sub.1-xSb with 0.ltoreq.x.ltoreq.0.5 epitaxially grown on a GaSb substrate. The FPA avoids the use of a mesa structure to isolate each photodetector element and instead uses impurity-doped regions formed in or about each photodetector for electrical isolation. This results in a substantially-planar structure in which the SLS is unbroken across the entire width of a 2-D array of the photodetector elements which are capped with an epitaxially-grown passivation layer to reduce or eliminate surface recombination. The FPA has applications for use in the wavelength range of 3-25 .mu.m.
FPA-FTIR Microspectroscopy for Monitoring Chemotherapy Efficacy in Triple-Negative Breast Cancer
NASA Astrophysics Data System (ADS)
Zawlik, Izabela; Kaznowska, Ewa; Cebulski, Jozef; Kolodziej, Magdalena; Depciuch, Joanna; Vongsvivut, Jitraporn; Cholewa, Marian
2016-11-01
Triple-negative breast cancer is the most aggressive breast cancer subtype with limited treatment options and a poor prognosis. Approximately 70% of triple-negative breast cancer patients fail to achieve a pathologic complete response (pCR) after chemotherapy due to the lack of targeted therapies for this subtype. We report here the development of a focal-plane-array Fourier transform infrared (FPA-FTIR) microspectroscopic technique combined with principal component analysis (PCA) for monitoring chemotherapy effects in triple-negative breast cancer patients. The PCA results obtained using the FPA-FTIR spectral data collected from the same patients before and after the chemotherapy revealed discriminatory features that were consistent with the pathologic and clinical responses to chemotherapy, indicating the potential of the technique as a monitoring tool for observing chemotherapy efficacy.
Strained layer superlattice focal plane array having a planar structure
Kim, Jin K; Carroll, Malcolm S; Gin, Aaron; Marsh, Phillip F; Young, Erik W; Cich, Michael J
2012-10-23
An infrared focal plane array (FPA) is disclosed which utilizes a strained-layer superlattice (SLS) formed of alternating layers of InAs and In.sub.xGa.sub.1-xSb with 0.ltoreq.x.ltoreq.0.5 epitaxially grown on a GaSb substrate. The FPA avoids the use of a mesa structure to isolate each photodetector element and instead uses impurity-doped regions formed in or about each photodetector for electrical isolation. This results in a substantially-planar structure in which the SLS is unbroken across the entire width of a 2-D array of the photodetector elements which are capped with an epitaxially-grown passivation layer to reduce or eliminate surface recombination. The FPA has applications for use in the wavelength range of 3-25 .mu.m.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziemer, B; Hubbard, L; Groves, E
2015-06-15
Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volumemore » CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r{sup 2} = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hubbard, L; Ziemer, B; Sadeghi, B
Purpose: To evaluate the accuracy of dynamic CT myocardial perfusion measurement using first pass analysis (FPA) and maximum slope models. Methods: A swine animal model was prepared by percutaneous advancement of an angioplasty balloon into the proximal left anterior descending (LAD) coronary artery to induce varying degrees of stenosis. Maximal hyperaemia was achieved in the LAD with an intracoronary adenosine drip (240 µg/min). Serial microsphere and contrast (370 mg/mL iodine, 30 mL, 5mL/s) injections were made over a range of induced stenoses, and dynamic imaging was performed using a 320-row CT scanner at 100 kVp and 200 mA. The FPAmore » CT perfusion technique was used to make vessel-specific myocardial perfusion measurements. CT perfusion measurements using the FPA and maximum slope models were validated using colored microspheres as the reference gold standard. Results: Perfusion measurements using the FPA technique (P-FPA) showed good correlation with minimal offset when compared to perfusion measurements using microspheres (P- Micro) as the reference standard (P -FPA = 0.96 P-Micro + 0.05, R{sup 2} = 0.97, RMSE = 0.19 mL/min/g). In contrast, the maximum slope model technique (P-MS) was shown to underestimate perfusion when compared to microsphere perfusion measurements (P-MS = 0.42 P -Micro −0.48, R{sup 2} = 0.94, RMSE = 3.3 mL/min/g). Conclusion: The results indicate the potential for significant improvements in accuracy of dynamic CT myocardial perfusion measurement using the first pass analysis technique as compared with the standard maximum slope model.« less
Cheetah: A high frame rate, high resolution SWIR image camera
NASA Astrophysics Data System (ADS)
Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob
2008-10-01
A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.
Jung, In-Keun; Park, Sang-Chul; Bin, Sung-Ah; Roh, Young Sup; Lee, John Hwan; Kim, Boo-Min
2016-03-01
The Maillard reaction has been well researched and used in the food industry and the fields of environmental science and organic chemistry. Here, we induced the Maillard reaction inside human hair and analyzed its effects by using Fourier transform infrared spectroscopy with a focal-plane array (FTIR-FPA) detector. We used arginine (A), glycine (G), and D-xylose (X) to generate the Maillard reaction by dissolving them in purified water and heating it to 150 °C. This label-free process generated a complex compound (named AGX after its ingredients) with a monomer structure, which was determined by using nuclear magnetic resonance (NMR) and FTIR-FPA. This compound was stable in hair and substantially increased its tensile strength. To our knowledge, we are the first to report the formation of this monomer in human hair, and our study provides insights into a new method that could be used to improve the condition of damaged or aging hair.
Performance enhancement of uncooled infrared focal plane array by integrating metamaterial absorber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Wei; Wen, Yongzheng; Yu, Xiaomei, E-mail: yuxm@pku.edu.cn
2015-03-16
This letter presents an infrared (IR) focal plane array (FPA) with metamaterial absorber (MMA) integrated to enhance its performance. A glass substrate, on which arrays of bimaterial cantilevers are fabricated as the thermal-sensitive pixels by a polyimide surface sacrificial process, is employed to allow the optical readout from the back side of the substrate. Whereas the IR wave radiates onto the FPA from the front side, which consequently avoids the energy loss caused by the silicon substrate compared with the previous works. This structure also facilitates the integration of MMA by introducing a layer of periodic square resonators atop themore » SiN{sub x} structural layer to form a metal/dielectric/metal stack with the gold mirror functioning as the ground plane. A comparative experiment was carried out on the FPAs that use MMA and ordinary SiN{sub x} as the absorbers, respectively. The performance improvement was verified by the evaluation of the absorbers as well as the imaging results of both FPAs.« less
Chen, Hongzhang; Li, Yanjun; Xu, Fujian
2013-11-01
A self-designed novel solid-state fermentation (SSF) bioreactor named "gas double-dynamic solid-state fermentation bioreactor (GDSFB)" showed great success in processes for the production of several valuable products. For the present study, a simple GDSFB (2 L in volume) was designed to investigate the impact of exhaust time on SSF performance. Both air pressure and vent aperture significantly influenced the exhaust time. The production of cellulase by Penicillium decumbens JUA10 was studied in this bioreactor. When the vent aperture was maintained at 0.2 cm, the highest FPA activity of 17.2 IU/g dry solid-state medium was obtained at an air pressure of 0.2 MPa (gauge pressure). When the air pressure was maintained at 0.2 MPa, a vent aperture of 0.3 cm gave the highest FPA activity of 18.0 IU/g dry solid-state medium. Further analysis revealed that the exhaust time was a crucial indicator of good performance in GDSFB.
Microwave spectrum, structure and dipole moment of 4-fluorophenylacetylene (4FPA)
NASA Astrophysics Data System (ADS)
Jang, Heesu; Ka, Soohyun; Dikkumbura, Asela S.; Peebles, Rebecca A.; Peebles, Sean A.; Oh, Jung Jin
2017-04-01
Using a chirped-pulse Fourier-transform microwave (CP-FTMW) spectrometer, a 6-18 GHz spectrum of 4-fluorophenylacetylene (4FPA) was measured and only a-type R-branch transitions were observed up to J = 9. Rotational constants and quartic centrifugal distortion constants for the normal isotopic species were determined based on Watson-S reduction: A = 5652.812(22) MHz, B = 966.92885(11) MHz, C = 825.67680(11) MHz, DJ = 0.01377(60) kHz, and DJK = 0.2468(61) kHz, with other three distortion constants fixed as DK = 0.6629 kHz, d1 = 2.386 Hz, and d2 = 0.989 Hz from ab initio results. For six kinds of carbon-13 isotopic species, 10-15 transitions were detected by a resonant cavity FTMW spectrometer in natural abundance, and rotational constants of each species were also determined by fitting transition frequencies. Gaseous molecular structures of 4FPA were derived via the least-squares fitting (r0) and substitution (rs) methods, and ab initio optimization (re). They were compared to the structures of benzene derivatives having fluorine and the acetylenic group as substituents. In addition, dipole moment component of 4FPA was also determined to be μa = μtotal = 0.8935(9) D from Stark effect measurements.
Durzan, Don J
2012-09-01
Cell fate, development timing and occurrence of reproductive versus apomictic development in gymnosperms are shown to be influenced by culture conditions in vitro. In this study, female parthenogenetic apomixis (fPA), androsporogenetic parthenogenesis (mAP) and progenesis were demonstrated using embryonal initials of Araucaria angustifolia in scaled-up cell suspensions passing through a single-cell bottleneck in darkness and in an artificial sporangium (AS). Expression was based on defined nutrition, hormones and feedforward-adaptive feedback process controls at 23-25 °C and in darkness. In fPA, the nucleus of an embryonal initial undergoes endomitosis and amitosis, forming a diploid egg-equivalent and an apoptotic ventral canal nucleus in a transdifferentiated archegonial tube. Discharge of egg-equivalent cells as parthenospores and their dispersal into the aqueous culture medium were followed by free-nuclear conifer-type proembryogenesis. This replaced the plesiomorphic and central features of proembryogenesis in Araucariaceae. Protoplasmic fusions of embryonal initials were used to reconstruct heterokaryotic expressions of fPA in multiwell plates. In mAP, restitutional meiosis (automixis) was responsible for androsporogenesis and the discharge of monads, dyads, tetrads and polyads. In a display of progenesis, reproductive development was brought to an earlier ontogenetic stage and expressed by embryonal initials. Colchicine increased polyploidy, but androspore formation became aberrant and fragmented. Aberrant automixis led to the formation of chromosomal bouquets, which contributed to genomic silencing in embryonal initials, cytomixis and the formation of pycnotic micronucleated cells. Dispersal of female and male parthenospores displayed heteromorphic asexual heterospory in an aqueous environment.
The performance of DC restoration function for MODIS thermal emissive bands
NASA Astrophysics Data System (ADS)
Wang, Zhipeng; Xiong, Xiaoxiong Jack; Shrestha, Ashish
2017-09-01
The DC restore (DCR) process of MODIS instrument maintains the output of a detector at focal plane assembly (FPA) within the dynamic range of subsequent analog-to-digital converter, by adding a specific offset voltage to the output. The DCR offset value is adjusted per scan, based on the comparison of the detector response in digital number (DN) collected from the blackbody (BB) view with target DN saved as an on-board look-up table. In this work, the MODIS DCR mechanism is revisited, with the trends of DCR offset being provided for thermal emissive bands (TEB). Noticeable changes have been occasionally found which coincide with significant detector gain change due to various instrumental events such as safe-mode anomaly or FPA temperature fluctuation. In general, MODIS DCR functionality has been effective and the change of DCR offset has no impact to the quality of MODIS data. One exception is the Earth view (EV) data saturation of Aqua MODIS LWIR bands 33, 35 ad 36 during BB warm-up cool-down (WUCD) cycle which has been observed since 2008. The BB view of their detectors saturate when the BB temperature is above certain threshold so the DCR cannot work as designed. Therefore, the dark signal DN fluctuates with the cold FPA (CFPA) temperature and saturate for a few hours per WUCD cycle, which also saturate the EV data sector within the scan. The CFPA temperature fluctuation peaked in 2012 and has been reduced in recent years and the saturation phenomenon has been easing accordingly. This study demonstrates the importance of DCR to data generation.
Lynch, Elizabeth
The FPA--formerly the Family Planning Association--celebrates its 75th anniversary this year. Since its inception, the association's remit has broadened from the provision of contraceptive advice to health education and help with sexual dysfunction. Before contraceptive services became available, women underwent multiple pregnancies. Until 1967, contraceptive advice was available only to married women. Family planning nurses now provide women with the contraceptive pill as well as injections and emergency contraception. The FPA provides termination of pregnancy and vasectomy services.
Not according to the high court, Professor Wolak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falk, Jonathan
2008-08-15
The FERC and its powers and actions related to ''just and reasonable'' prices are discussed in the aftermath of the California crisis. The decision in the case Morgan Stanley Capital Group Inc. v. Public Utility District No. 1 of Snohomish County et al. is addressed. The author concludes, FERC has an absolutely vital role to play in fulfilling its obligations under the FPA and in fostering a system that creates ''just and reasonable'' prices. It must certify markets that will be sufficiently competitive to allow market prices to become set. It must continually monitor those markets to ensure that competitivemore » conditions are met. It must enforce prohibitions against fraud and market manipulation. But if it does those things, it is entitled under the FPA to certify the prices thus generated as ''just and reasonable.'' And the justification is the long-run welfare of consumers, exactly the group the FPA was enacted to protect.« less
Reyes-Núñez, Virginia; Galo-Hooker, Evelyn; Pérez-Romano, Beatriz; Duque, Ricardo E; Ruiz-Arguelles, Alejandro; Garcés-Eisele, Javier
2018-01-01
The aim of this work was to simultaneously use multiplex ligation-dependent probe amplification (MLPA) assay and flow cytometric DNA ploidy analysis (FPA) to detect aneuploidy in patients with newly diagnosed acute leukemia. MLPA assay and propidium iodide FPA were used to test samples from 53 consecutive patients with newly diagnosed acute leukemia referred to our laboratory for immunophenotyping. Results were compared by nonparametric statistics. The combined use of both methods significantly increased the rate of detection of aneuploidy as compared to that obtained by each method alone. The limitations of one method are somehow countervailed by the other and vice versa. MPLA and FPA yield different yet complementary information concerning aneuploidy in acute leukemia. The simultaneous use of both methods might be recommended in the clinical setting. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.
Effects of space flight and mixing on bacterial growth in low volume cultures
NASA Technical Reports Server (NTRS)
Kacena, M. A.; Manfredi, B.; Todd, P.
1999-01-01
Previous investigations have shown that liquid suspension bacterial cultures grow to higher cell concentrations in spaceflight than on Earth. None of these studies included ground-control experiments designed to evaluate the fluid effects potentially responsible for the reported increases. Therefore, the emphasis of this research was to both confirm differences in final cell concentration between 1g and microgravity cultures, and to examine the effects of mixing as a partial explanation for this difference. Flight experiments were performed in the Fluid Processing Apparatus (FPA), aboard Space Shuttle Missions STS-63 and STS-69, with simultaneous 1g static and agitated controls. Additional static 1g, agitated, and clino-rotated controls were performed in 9-ml culture tubes. This research revealed that both E. coli and B. subtilis samples cultured in space flight grew to higher final cell densities (120-345% increase) than simultaneous static 1g controls. The final cell concentration of E. coli cells cultured under agitation was 43% higher than in static 1g cultures and was 102% higher with clino-rotation. However, for B. subtilis cultures grown while being agitated on a shaker or clino-rotated, the final cell concentrations were nearly identical to those of the simultaneous static 1g controls. Therefore, these data suggest that the unique fluid quiescence in the microgravity environment (lack of sedimentation, creating unique transfer of nutrients and waste products), was responsible for the enhanced bacterial proliferation reported in this and other studies.
Limb flexion-induced axial compression and bending in human femoropopliteal artery segments.
Poulson, William; Kamenskiy, Alexey; Seas, Andreas; Deegan, Paul; Lomneth, Carol; MacTaggart, Jason
2018-02-01
High failure rates of femoropopliteal artery (FPA) interventions are often attributed in part to severe mechanical deformations that occur with limb movement. Axial compression and bending of the FPA likely play significant roles in FPA disease development and reconstruction failure, but these deformations are poorly characterized. The goal of this study was to quantify axial compression and bending of human FPAs that are placed in positions commonly assumed during the normal course of daily activities. Retrievable nitinol markers were deployed using a custom-made catheter system into 28 in situ FPAs of 14 human cadavers. Contrast-enhanced, thin-section computed tomography images were acquired with each limb in the standing (180 degrees), walking (110 degrees), sitting (90 degrees), and gardening (60 degrees) postures. Image segmentation and analysis allowed relative comparison of spatial locations of each intra-arterial marker to determine axial compression and bending using the arterial centerlines. Axial compression in the popliteal artery (PA) was greater than in the proximal superficial femoral artery (SFA) or the adductor hiatus (AH) segments in all postures (P = .02). Average compression in the SFA, AH, and PA ranged from 9% to 15%, 11% to 19%, and 13% to 25%, respectively. The FPA experienced significantly more acute bending in the AH and PA segments compared with the proximal SFA (P < .05) in all postures. In the walking, sitting, and gardening postures, average sphere radii in the SFA, AH, and PA ranged from 21 to 27 mm, 10 to 18 mm, and 8 to 19 mm, whereas bending angles ranged from 150 to 157 degrees, 136 to 147 degrees, and 137 to 148 degrees, respectively. The FPA experiences significant axial compression and bending during limb flexion that occur at even modest limb angles. Moreover, different segments of the FPA appear to undergo significantly different degrees of deformation. Understanding the effects of limb flexion on axial compression and bending might assist with reconstructive device selection for patients requiring peripheral arterial disease intervention and may also help guide the development of devices with improved characteristics that can better adapt to the dynamic environment of the lower extremity vasculature. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Mayer, Bernhard X; Mensik, Christa; Krishnaswami, Sriram; Derendorf, Hartmut; Eichler, Hans-Georg; Schmetterer, Leopold; Wolzt, Michael
1999-01-01
Aims It has been demonstrated that inhibition of endothelium derived nitric oxide with NG-monomethyl-l-arginine (l-NMMA) results in a different cardiac and peripheral vascular response. The purpose of this study was to investigate the pharmacokinetic-pharmacodynamic profile of l-NMMA and pharmacokinetic interactions with l-arginine in healthy subjects. Methods Plasma pharmacokinetics were analysed from two different studies: In study 1, 3 mg kg−1 l-NMMA was administered i.v. over 5 min and systemic haemodynamics, cardiac output (CO), fundus pulsation amplitude (FPA), and NO-exhalation (exhNO) were measured at baseline and 15, 65, 95, 155, and 305 min after start of drug administration (n=7). In study 2, 17 mg kg−1 min−1 of the physiologic substrate for nitric oxide synthase, l-arginine, was coinfused i.v. over 30 min with a primed constant infusion of 50 μg kg−1 min−1 l-NMMA (n=8). Results Bolus infusion of l-NMMA resulted in a maximum plasma concentration of 12.9±3.4 μg ml−1 (mean±s.d.) with elimination half-life of 63.5±14.5 min and clearance of 12.2±3.5 ml min−1 kg−1 and caused a small hypertensive response, decreased CO by 13%, FPA by 26%, exhNO by 46% and increased systemic vascular resistance by 16% (P<0.05 each) 15 min after start of drug administration. Although only limited data points were available in the l-NMMA plasma concentration range between 0 and 4 μg ml−1, drug effects over time were in good agreement with an Emax model (r2>0.98 each), which also suggested that concentrations producing half-maximum effects were higher for FPA than for CO and exhNO. The coinfusion with l-arginine caused a nearly two-fold increase in plasma l-NMMA levels, indicating a pharmacokinetic interaction. Conclusions In the absence of a systemic hypertensive response, l-NMMA significantly decreased CO, exhNO, and FPA. The concentration calculated to produce a half maximal effect was equivalent for exhNO and CO, but markedly higher for FPA. Furthermore, measurement of FPA is susceptible to changes in l-NMMA levels at small plasma concentrations. PMID:10336578
Spectral and Polarimetric Imagery Collection Experiment (SPICE) Longwave Infrared Spectral Dataset
2014-09-01
radiance. Its 320x256 LWIR photovoltaic mercury cadmium telluride (PV MCT ) focal plane array (FPA) detectors are particularly sensitive to thermal...good as one can expect using the technology employed by Telops to manufacture these sensors, i.e., FPA of PV MCT detectors cooled to 65 K. We also...channeling in spectral data recorded by the Telops Hyper-Cam; the spectral ripple ( noise ), although embedded in the data, does not significantly change
Future Trends in MIcroelectronics: Up the Nano Creek
2006-06-01
developed focal plane arrays (FPA)3 in addition to emphasizing future development in UV-to-far infrared multicolor FPA detectors 5 for next generation... detectors ", IEEE J. Quantum Electronics 35, 1685 (1999). 3. P. Bois, E. Costard, X. Marcadet, and E. Herniou, "Development of quantum well infrared ...photodetector array", Infrared Phys. Technol. 44, 369 (2003). 5. M. N. Abedin, T. F. Refaat, J. M. Zawodny, et al., "Multicolor focal plane array detector
Report of mass communication Ceylon: October 1969-December 31, 1970.
1971-01-01
Experience with media usage by the FPA (Family Planning Association of Ceylon between October 1969 and December 1970 is summarized. During this time, the Association purchased 100-200 column inches each of contract advertising space in 26 newspapers. The press has published 268 press release, I.P.P.F., U.N., features and international press clipping in addition to specialized medical articles on family planning methods and 8 articles by FPA office-bearers. In January 1970; the Association launched local radio's first 5-minute daily commercial in Sinhala and Tamil. The program was repeated from April to July 1970. A series of 5 slides on family planning has been shown in movie theathers and more sets are being prepared for viewing. Posters have been used on buses and are currently on display on the National Railways project. Folders, leaflect, and poster calendars have been produced and used. Family Planning stickers have put up in 700 barber saloons. The FPA had stalls in the 1970 3-day National Exhibition at Batticaloa, the 4-day U.N. Poster Exhibition at Badulla, and the 2-week Ceylon Medical College Centenary Exhibition in Colombo. The Information Unit of FPA has answered 18, 541 written inquiries. A family planning communication us regularly dispatched to members of the Cabinet, government and opposition members of parliament, senators, chairmen of local bodies, and key trade union officials.
A New Two-Color Infrared Photodetector Design Using INGAAS/INALAS Coupled Quantum Wells
1999-08-01
that spans the mid-wave infrared (MWIR) and the long-wave infrared ( LWIR ) atmospheric transmission windows of 3 to 5 and 8 to 12 µm, respectively...This leads to natural pixel registration in an FPA application. QWIP FPAs operating in two LWIR bands have been demonstrated,2 and, recently, the...Abstract unlimited Number of Pages 15 color FPA with simultaneous readout of an LWIR (9-µm peak) and an MWIR (5.1-µm peak) band was tested3 and shown to
2013-04-01
liquid nitrogen cooled mercury cadmium telluride ( MCT ) detector and compare their performance to a commercial FT-IR imaging instrument. We examine the...telluride ( MCT ) detector (InfraRed Associates, Stuart, FL), and in a second widefield imaging configuration, we employed a cooled focal plane array (FPA...experiment, a cooled focal plane array (FPA) was substituted for the bolometer. (b) A cooled single-element MCT detector is utilized with an adjustable
NASA Astrophysics Data System (ADS)
Gutschwager, Berndt; Hollandt, Jörg
2017-01-01
We present a novel method of nonuniformity correction (NUC) of infrared cameras and focal plane arrays (FPA) in a wide optical spectral range by reading radiance temperatures and by applying a radiation source with an unknown and spatially nonhomogeneous radiance temperature distribution. The benefit of this novel method is that it works with the display and the calculation of radiance temperatures, it can be applied to radiation sources of arbitrary spatial radiance temperature distribution, and it only requires sufficient temporal stability of this distribution during the measurement process. In contrast to this method, an initially presented method described the calculation of NUC correction with the reading of monitored radiance values. Both methods are based on the recording of several (at least three) images of a radiation source and a purposeful row- and line-shift of these sequent images in relation to the first primary image. The mathematical procedure is explained in detail. Its numerical verification with a source of a predefined nonhomogeneous radiance temperature distribution and a thermal imager of a predefined nonuniform FPA responsivity is presented.
Radiometric packaging of uncooled bolometric infrared focal plane arrays
NASA Astrophysics Data System (ADS)
García-Blanco, Sonia; Pope, Timothy; Côté, Patrice; Leclerc, Mélanie; Ngo Phong, Linh; Châteauneuf, François
2017-11-01
INO has a wide experience in the design and fabrication of different kinds of microbolometer focal plane arrays (FPAs). In particular, a 512x3 pixel microbolometer FPA has been selected as the sensor for the New Infrared Sensor Technology (NIRST) instrument, one of the payloads of the SACD/Aquarius mission. In order to make the absolute temperature measurements necessary for many infrared Earth observation applications, the microbolometer FPA must be integrated into a package offering a very stable thermal environment. The radiometric packaging technology developed at INO presents an innovative approach since it was conceived to be modular and adaptable for the packaging of different microbolometer FPAs and for different sets of assembly requirements without need for requalification of the assembly process. The development of the radiometric packaging technology has broadened the position of INO as a supplier of radiometric detector modules integrating FPAs of microbolometers inside a radiometric package capable of achieving the requirements of different space missions. This paper gives an overview of the design of INO's radiometric package. Key performance parameters are also discussed and the test campaign conducted with the radiometric package is presented.
High-resolution panoramic images with megapixel MWIR FPA
NASA Astrophysics Data System (ADS)
Leboucher, Vincent; Aubry, Gilles
2014-06-01
In the continuity of its current strategy, HGH maintains a deep effort in developing its most recent product family: the infrared (IR) panoramic 360-degree surveillance sensors. During the last two years, HGH optimized its prototype Middle Wave IR (MWIR) panoramic sensor IR Revolution 360 HD that gave birth to Spynel-S product. Various test campaigns proved its excellent image quality. Cyclope, the software associated with Spynel, benefitted from recent image processing improvements and new functionalities such as target geolocalization, long range sensor slue to cue and facilitated forensics analysis. In the frame of the PANORAMIR project sustained by the DGA (Délégation Générale de l'Armement), HGH designed a new extra large resolution sensor including a MWIR megapixel Focal Plane Array (FPA) detector (1280×1024 pixels). This new sensor is called Spynel-X. It provides outstanding resolution 360-degree images (with more than 100 Mpixels). The mechanical frame of Spynel (-S and -X) was designed with the collaboration of an industrial design agency. Spynel got the "Observeur du Design 2013" label.
MTF Determination of SENTINEL-4 Detector Arrays
NASA Astrophysics Data System (ADS)
Reulke, R.; Sebastian, I.; Williges, C.; Hohn, R.
2017-05-01
The Institute for Optical Sensor Systems was involved in many international space projects in recent years. These include, for example, the fokal plane array (FPA) of the hyperspectral sensors ENMAP or Sentinel-4, but also the FPA for the high resolution FPA for Kompsat-3. An important requirement of the customer is the measurement of the detector MTF for different wavelengths. A measuring station under clean room conditions and evaluation algorithms was developed for these measurements. The measurement setup consist of a collimator with slit target in focus for illumination at infinity, a gimbal mounted detector facing an auxiliary lens in front, a halogen lamp with monochromator or filter, as well as optical and electrical ground support equipment. Different targets and therefore also different measurement and data evaluation opportunities are possible with this setup. Examples are slit, edge, pin hole but also a Siemens star. The article describes the measurement setup, the different measuring and evaluation procedures and exemplary results for Sentinel-4 detector.
Webb Instruments Perfected to Microscopic Levels
2014-06-20
Dressed in a cleanroom suit to prevent contamination, Optics Technician Jeff Gum aligns a replacement Focal Plane Assembly (FPA) with a powerful three-dimensional microscope at NASA's Goddard Space Flight Center in Greenbelt, Md. This FPA will be installed on the Near Infrared Camera (NIRCam) instrument, which has unique components that are individually tailored to see in a particular infrared wavelength range. By using the microscope, Gum ensures the FPA detectors are characterized and ready for installation onto NIRCam, the James Webb Space Telescope's primary imager that will see the light from the earliest stars and galaxies that formed in the universe. Credit: NASA/Goddard/Chris Gunn NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Modulation Transfer Function of Infrared Focal Plane Arrays
NASA Technical Reports Server (NTRS)
Gunapala, S. D.; Rafol, S. B.; Ting, D. Z.; Soibel, A.; Hill, C. J.; Khoshakhlagh, A.; Liu, J. K.; Mumolo, J. M.; Hoglund, L.; Luong, E. M.
2015-01-01
Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.
The CHROMA focal plane array: a large-format, low-noise detector optimized for imaging spectroscopy
NASA Astrophysics Data System (ADS)
Demers, Richard T.; Bailey, Robert; Beletic, James W.; Bernd, Steve; Bhargava, Sidharth; Herring, Jason; Kobrin, Paul; Lee, Donald; Pan, Jianmei; Petersen, Anders; Piquette, Eric; Starr, Brian; Yamamoto, Matthew; Zandian, Majid
2013-09-01
The CHROMA (Configurable Hyperspectral Readout for Multiple Applications) is an advanced Focal Plane Array (FPA) designed for visible-infrared imaging spectroscopy. Using Teledyne's latest substrateremoved HgCdTe detector, the CHROMA FPA has very low dark current, low readout noise and high, stable quantum efficiency from the deep blue (390nm) to the cutoff wavelength. CHROMA has a pixel pitch of 30 microns and is available in array formats ranging from 320×480 to 1600×480 pixels. Users generally disperse spectra over the 480 pixel-length columns and image spatially over the n×160 pixellength rows, where n=2, 4, 8, 10. The CHROMA Readout Integrated Circuit (ROIC) has Correlated Double Sampling (CDS) in pixel and generates its own internal bias signals and clocks. This paper presents the measured performance of the CHROMA FPA with 2.5 micron cutoff wavelength including the characterization of noise versus pixel gain, power dissipation and quantum efficiency.
The University of Florida's next-generation cryogenic infrared focal plane array controller system
NASA Astrophysics Data System (ADS)
Raines, Steven N.; Boreman, Glenn D.; Eikenberry, Stephen S.; Bandyopadhyay, Reba M.; Quijano, Ismael
2008-07-01
The Infrared Instrumentation Group at the University of Florida has substantial experience building IR focal plane array (FPA) controllers and seamlessly integrating them into the instruments that it builds for 8-meter class observatories, including writing device drivers for UNIX-based computer systems. We report on a design study to investigate implementing an ASIC from Teledyne Imaging Systems (TIS) into our IR FPA controller while simultaneously replacing TIS's interface card with one that eliminates the requirement for a Windows-OS computer within the instrument's control system.
Quantum Well and Quantum Dot Modeling for Advanced Infrared Detectors and Focal Plane Arrays
NASA Technical Reports Server (NTRS)
Ting, David; Gunapala, S. D.; Bandara, S. V.; Hill, C. J.
2006-01-01
This viewgraph presentation reviews the modeling of Quantum Well Infrared Detectors (QWIP) and Quantum Dot Infrared Detectors (QDIP) in the development of Focal Plane Arrays (FPA). The QWIP Detector being developed is a dual band detector. It is capable of running on two bands Long-Wave Infrared (LWIR) and Medium Wavelength Infrared (MWIR). The same large-format dual-band FPA technology can be applied to Quantum Dot Infrared Photodetector (QDIP) with no modification, once QDIP exceeds QWIP in single device performance. Details of the devices are reviewed.
Large-format InGaAs focal plane arrays for SWIR imaging
NASA Astrophysics Data System (ADS)
Hood, Andrew D.; MacDougal, Michael H.; Manzo, Juan; Follman, David; Geske, Jonathan C.
2012-06-01
FLIR Electro Optical Components will present our latest developments in large InGaAs focal plane arrays, which are used for low light level imaging in the short wavelength infrared (SWIR) regime. FLIR will present imaging from their latest small pitch (15 μm) focal plane arrays in VGA and High Definition (HD) formats. FLIR will present characterization of the FPA including dark current measurements as well as the use of correlated double sampling to reduce read noise. FLIR will show imagery as well as FPA-level characterization data.
Color camera computed tomography imaging spectrometer for improved spatial-spectral image accuracy
NASA Technical Reports Server (NTRS)
Wilson, Daniel W. (Inventor); Bearman, Gregory H. (Inventor); Johnson, William R. (Inventor)
2011-01-01
Computed tomography imaging spectrometers ("CTIS"s) having color focal plane array detectors are provided. The color FPA detector may comprise a digital color camera including a digital image sensor, such as a Foveon X3.RTM. digital image sensor or a Bayer color filter mosaic. In another embodiment, the CTIS includes a pattern imposed either directly on the object scene being imaged or at the field stop aperture. The use of a color FPA detector and the pattern improves the accuracy of the captured spatial and spectral information.
GIFTS SM EDU Data Processing and Algorithms
NASA Technical Reports Server (NTRS)
Tian, Jialin; Johnson, David G.; Reisse, Robert A.; Gazarik, Michael J.
2007-01-01
The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration stage. The calibration procedures can be subdivided into three stages. In the pre-calibration stage, a phase correction algorithm is applied to the decimated and filtered complex interferogram. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected blackbody reference spectra. In the radiometric calibration stage, we first compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. During the post-processing stage, we estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. We then implement a correction scheme that compensates for the effect of fore-optics offsets. Finally, for off-axis pixels, the FPA off-axis effects correction is performed. To estimate the performance of the entire FPA, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation.
Lightweight uncooled TWS equipped with catadioptric optics and microscan mechanism
NASA Astrophysics Data System (ADS)
Bergeron, A.; Jerominek, H.; Doucet, M.; Lagacé, F.; Desnoyers, N.; Bernier, S.; Mercier, L.; Boucher, M.-A.; Jacob, M.; Alain, C.; Pope, T. D.; Laou, P.
2006-05-01
A rugged lightweight thermal weapon sight (TWS) prototype was developed at INO in collaboration with DRDC-Valcartier. This TWS model is based on uncooled bolometer technology, ultralight catadioptric optics, ruggedized mechanics and electronics, and extensive onboard processing capabilities. The TWS prototype operates in a single 8-12 μm infrared (IR) band. It is equipped with a unique lightweight athermalized catadioptric objective and a bolometric IR imager with an INO focal plane array (FPA). Microscan technology allows the use of a 160 x 120 pixel FPA with a pitch of 50 μm to achieve a 320 × 240 pixel resolution image thereby avoiding the size (larger optics) and cost (expensive IR optical components) penalties associated with the use of larger format arrays. The TWS is equipped with a miniature shutter for automatic offset calibration. Based on the operation of the FPA at 100 frames per second (fps), real-time imaging with 320 x 240 pixel resolution at 25 fps is available. This TWS is also equipped with a high resolution (857 x 600 pixels) OLED color microdisplay and an integrated wireless digital RF link. The sight has an adjustable and selectable electronic reticule or crosshair (five possible reticules) and a manual focus from 5 m to infinity standoff distance. Processing capabilities are added to introduce specific functionalities such as image inversion (black hot and white hot), image enhancement, and pixel smoothing. This TWS prototype is very lightweight (~ 1100 grams) and compact (volume of 93 cubic inches). It offers human size target detection at 800 m and recognition at 200 m (Johnson criteria). With 6 Li AA batteries, it operates continuously for 5 hours and 20 minutes at room temperature. It can operate over the temperature range of -30 °C to +40 °C and its housing is completely sealed. The TWS is adapted to weaver or Picatinny rail mounting. The overall design of the TWS prototype is based on feedbacks of users to achieve improved user-friendly (e.g. no pull-down menus and no electronic focusing) and ergonomic (e.g. locations of buttons) features.
NASA Astrophysics Data System (ADS)
Morikawa, Junko; Zamengo, Massimiliano; Kato, Yukitaka
2016-05-01
The global interest in energy applications activates the advanced study about the molten salts in the usage of fluids in the power cycle, such as for transport and heat storage in solar power facilities. However, the basic properties of molten salts show a general scattering in characterization especially in thermal properties. It is suggested that new studies are required on the measurement of thermal properties of solar salts using recent technologies. In this study, micro-scale heat transfer and phase change in molten salts are presented using our originally developed device: the micro-bolometer Infrared focal plane arrays (IR FPA) measuring system is a portable type instrument, which is re-designed to measure the thermal phenomena in high temperature up to 700 °C or higher. The superimpose system is newly setup adjusted to the signal processing in high temperature to realize the quantitative thermal imaging, simultaneously. The portable type apparatus for a quantitative micro-scale thermography using a micro-bolometer has been proposed based on an achromatic lens design to capture a micro-scale image in the long-wave infrared, a video signal superimposing for the real time emissivity correction, and a pseudo acceleration of a timeframe. Combined with the superimpose technique, the micro-scale thermal imaging in high temperature is achieved and the molten flows of the solar salts, sodium nitrate, and potassium nitrate are successfully observed. The solar salt, the mixture of sodium nitrate and potassium nitrate, shows a different shape of exothermic heat front morphology in the lower phase transition (solidification) temperature than the nitrates on cooling. The proposed measuring technique will be utilized to accelerate the screening step to determine the phase diagram and the eutectics of the multiple mixtures of candidate molten salts, which may be used as heat transport medium from the concentrated solar power to a processing plant for thermal energy storage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hubbard, L; Ziemer, B; Lipinski, J
Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosismore » level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.« less
Can IR scene projectors reduce total system cost?
NASA Astrophysics Data System (ADS)
Ginn, Robert; Solomon, Steven
2006-05-01
There is an incredible amount of system engineering involved in turning the typical infrared system needs of probability of detection, probability of identification, and probability of false alarm into focal plane array (FPA) requirements of noise equivalent irradiance (NEI), modulation transfer function (MTF), fixed pattern noise (FPN), and defective pixels. Unfortunately, there are no analytic solutions to this problem so many approximations and plenty of "seat of the pants" engineering is employed. This leads to conservative specifications, which needlessly drive up system costs by increasing system engineering costs, reducing FPA yields, increasing test costs, increasing rework and the never ending renegotiation of requirements in an effort to rein in costs. These issues do not include the added complexity to the FPA factory manager of trying to meet varied, and changing, requirements for similar products because different customers have made different approximations and flown down different specifications. Scene generation technology may well be mature and cost effective enough to generate considerable overall savings for FPA based systems. We will compare the costs and capabilities of various existing scene generation systems and estimate the potential savings if implemented at several locations in the IR system fabrication cycle. The costs of implementing this new testing methodology will be compared to the probable savings in systems engineering, test, rework, yield improvement and others. The diverse requirements and techniques required for testing missile warning systems, missile seekers, and FLIRs will be defined. Last, we will discuss both the hardware and software requirements necessary to meet the new test paradigm and discuss additional cost improvements related to the incorporation of these technologies.
Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey
2018-01-01
Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746
NASA Astrophysics Data System (ADS)
Roy, Sunil K.; Kumar, M. Ravi; Davuluri, Srinagesh
2017-08-01
This study presents 106 splitting and 40 null measurements of source side anisotropy in subduction zones, utilizing direct S waves registered at two stations sited on the Indian continent, which show null shear wave splitting measurements for SKS phases. Our results suggest that trench-parallel anisotropy is dominant beneath the Philippines, Mariana, Izu-Bonin, and edge of the Java slab, while plate motion-parallel anisotropy is observed beneath the Solomon, Aegean, Japan, and Java slabs. Results from Kuril and Aleutian regions reveal trench-oblique anisotropy. We chose to interpret these observations primarily in terms of mantle flow beneath a subduction zone. While the two-dimensional (2-D) slab entrained flow model offers a simple explanation for trench-normal fast polarization azimuths (FPA), the trench-parallel FPA can be reconciled by extension due to slab rollback. The model that invokes age of the subducting lithosphere can explain anisotropy in the subslab, derived from rays recorded at the updip stations. However, when downdip stations are used, contributions from the slab and supraslab need to be considered. In Japan, anisotropy in the subslab mantle shallower than 300 km might be associated with trench-parallel mantle flow resulting in the alignment of FPA in the same direction. Anisotropy in the deeper part, above the transition zone, is probably associated with 2-D flow resulting in trench-normal FPA. Anisotropy in the Mariana Trench might be associated with trench-parallel mantle flow in the supraslab region, with similar deformation in the upper mantle and the transition zone.
Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey
2018-05-01
Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.
High-performance IR detector modules
NASA Astrophysics Data System (ADS)
Wendler, Joachim; Cabanski, Wolfgang; Rühlich, Ingo; Ziegler, Johann
2004-02-01
The 3rd generation of infrared (IR) detection modules is expected to provide higher video resolution, advanced functions like multi band or multi color capability, higher frame rates, and better thermal resolution. AIM has developed staring and linear high performance focal plane arrays (FPA) integrated into detector/dewar cooler assemblies (IDCA). Linear FPA"s support high resolution formats such as 1920 x 1152 (HDTV), 1280 x 960, or 1536 x 1152. Standard format for staring FPA"s is 640 x 512. In this configuration, QEIP devices sensitive in the 8 10 µm band as well as MCT devices sensitive in the 3.4 5.0 µm band are available. A 256 x 256 high speed detection module allows a full frame rate >800 Hz. Especially usability of long wavelength devices in high performance FLIR systems does not only depend on the classical electrooptical performance parameters such as NEDT, detectivity, and response homogeneity, but are mainly characterized by the stability of the correction coefficients used for image correction. The FPA"s are available in suited integrated detector/dewar cooler assemblies. The linear cooling engines are designed for maximum stability of the focal plane temperature, low operating temperatures down to 60K, high MTTF lifetimes of 6000h and above even under high ambient temperature conditions. The IDCA"s are equipped with AIM standard or custom specific command and control electronics (CCE) providing a well defined interface to the system electronics. Video output signals are provided as 14 bit digital data rates up to 80 MHz for the high speed devices.
Effect of heparin bonding on catheter-induced fibrin formation and platelet activation.
Nichols, A B; Owen, J; Grossman, B A; Marcella, J J; Fleisher, L N; Lee, M M
1984-11-01
Pathologic and experimental evidence indicates that platelet activation and fibrin formation contribute to the pathogenesis of angina pectoris, coronary vasospasm and myocardial infarction. Detection of localized intravascular platelet activation and fibrin formation in vivo by selective blood sampling requires catheters that do not induce coagulation ex vivo. We studied the effect of heparin bonding of catheter surfaces on activation of the coagulation system by cardiovascular catheters. Woven Dacron, polyvinylchloride, and polyurethane catheters were tested and compared with identical catheters with heparin-bonded surfaces in 47 patients undergoing percutaneous cardiac catheterization. Platelet activation was measured by radioimmunoassay of plasma platelet factor 4 (PF4), beta-thromboglobulin (BTG), and thromboxane B2 (TXB2) in blood samples withdrawn through catheters, and fibrin formation was assessed by determination of fibrinopeptide A (FPA) levels. In blood samples collected through conventional catheters, FPA, PF4, BTG, and TXB2 levels were markedly elevated; blood sampling through heparin-bonded catheters had no significant effect on FPA, PF4, BTG, or TXB2 levels. Scanning electron microscopy disclosed extensive platelet aggregates and fibrin strands adherent to the surface of conventional catheters but not to heparin-bonded catheter surfaces. This study demonstrates that (1) collection of blood samples through cardiovascular catheters causes artifactual elevation of FPA, PF4, BTG, and TXB2 levels, and (2) heparin-bonded catheter surfaces effectively prevent catheter-induced platelet alpha-granule release and fibrin formation on catheter surfaces. Heparin-bonded catheters will facilitate investigation of the role of intravascular coagulation in coronary artery disease by eliminating catheter-induced fibrin formation and platelet activation.
Low-SWAP Lidar Instrument for Arctic Ice Sheet Mass Balance Monitoring Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, George; Barsic, David
To meet the need to obtain statistically significant data in the North Slope of Alaska (NSA) in support of climate models, Voxtel is developing an nmanned-aircraft-system (UAS)-optimized lidar focal plane array (FPA) and lidar instrument design that integrates the most recent developments in optics, electronics, and computing. Bound by the size, weight, and power (SWAP) budget of low altitude/long endurance (LALE) small UAS (SUAS) platforms—a design tradeoff study was conducted. The class of SUAS considered typically: operates at altitudes between 150 meters and 2,000 meters; accommodates payloads weighing less than 5 kg; encompasses no more than 4,000 cm3 of space;more » and consumes no more than 50 watts of power. To address the SWAP constraints, a lowpower standalone strap-down (gimbal-less) lidar was developed based on single-photon-counting silicon avalanche photodiodes. To reduce SWAP, a lidar FPA design capable of simultaneous imaging and lidar was developed. The 532-nm-optimized FPA modular design was developed for easy integration, as a lidar payload, in any of a variety of SUAS platforms.« less
Xia, Ying; Yang, Lirong; Xia, Liming
2018-06-16
The industrial application of Trichoderma reesei has been greatly limited by insufficient β-glucosidase activity in its cellulase system. In this study, a novel β-glucosidase expression cassette was constructed and integrated at the target site in T. reesei ZU-02, which achieved the overexpression of β-glucosidase gene and in situ disruption of the cellulase transcriptional repressor ACE1. The resulting transformants showed significant increase in both β-glucosidase activity (BGA) and filter paper activity (FPA). The BGA and FPA increased to 25.13 IU/mL and 20.06 FPU/mL, respectively, 167- and 2.45-fold higher than that of the host strain. Meanwhile, the obtained cellulase system exhibited improved ratio of BGA to FPA, leading to better synergistic effect between cellulase components. Furthermore, submerged fermentation of the transformant was established in 50 m 3 fermenter yielding 112.2 IU/mL β-glucosidase and 89.76 FPU/mL total cellulase. The newly constructed T. reesei transformant achieved improved hydrolysis yield (90.6%) with reduced enzyme loading (15 FPU/g substrate).
Correction method for stripe nonuniformity.
Qian, Weixian; Chen, Qian; Gu, Guohua; Guan, Zhiqiang
2010-04-01
Stripe nonuniformity is very typical in line infrared focal plane arrays (IR-FPA) and uncooled staring IR-FPA. In this paper, the mechanism of the stripe nonuniformity is analyzed, and the gray-scale co-occurrence matrix theory and optimization theory are studied. Through these efforts, the stripe nonuniformity correction problem is translated into the optimization problem. The goal of the optimization is to find the minimal energy of the image's line gradient. After solving the constrained nonlinear optimization equation, the parameters of the stripe nonuniformity correction are obtained and the stripe nonuniformity correction is achieved. The experiments indicate that this algorithm is effective and efficient.
Forward Period Analysis Method of the Periodic Hamiltonian System.
Wang, Pengfei
2016-01-01
Using the forward period analysis (FPA), we obtain the period of a Morse oscillator and mathematical pendulum system, with the accuracy of 100 significant digits. From these results, the long-term [0, 1060] (time unit) solutions, ranging from the Planck time to the age of the universe, are computed reliably and quickly with a parallel multiple-precision Taylor series (PMT) scheme. The application of FPA to periodic systems can greatly reduce the computation time of long-term reliable simulations. This scheme provides an efficient way to generate reference solutions, against which long-term simulations using other schemes can be tested.
Infrared Detector Activities at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Abedin, M. N.; Refaat, T. F.; Sulima, O. V.; Amzajerdian, F.
2008-01-01
Infrared detector development and characterization at NASA Langley Research Center will be reviewed. These detectors were intended for ground, airborne, and space borne remote sensing applications. Discussion will be focused on recently developed single-element infrared detector and future development of near-infrared focal plane arrays (FPA). The FPA will be applied to next generation space-based instruments. These activities are based on phototransistor and avalanche photodiode technologies, which offer high internal gain and relatively low noise-equivalent-power. These novel devices will improve the sensitivity of active remote sensing instruments while eliminating the need for a high power laser transmitter.
Agnesi, Filippo; Tye, Susannah J.; Bledsoe, Jonathan M.; Griessenauer, Christoph J.; Kimble, Christopher J.; Sieck, Gary C.; Bennet, Kevin E.; Garris, Paul A.; Blaha, Charles D.; Lee, Kendall H.
2009-01-01
Object In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. Methods The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme-linked electrode to measure glutamate; and 3) a multiple enzyme-linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. Results The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. Conclusions By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery. PMID:19425899
Agnesi, Filippo; Tye, Susannah J; Bledsoe, Jonathan M; Griessenauer, Christoph J; Kimble, Christopher J; Sieck, Gary C; Bennet, Kevin E; Garris, Paul A; Blaha, Charles D; Lee, Kendall H
2009-10-01
In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme-linked electrode to measure glutamate; and 3) a multiple enzyme-linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.
1992-01-01
tactical computers. The module must correct for optical irregularities in illumination, pixel gain, offset nonuniformities due to dark currents and...large search FOR, for IR FPA. DESCRIPTION: Large area staring IR lPAs in both Medium Wavelength Infrared (MWIR) and Long Wavelength Infrared ( LWIR ) are a...of HTS materials to BLIP limited detection of radiation in the optical, IR, MWIR, and LWIR bands as well as for signal processing applications is also
SWIR HgCdTe avalanche photiode focal plane array performances evaluation
NASA Astrophysics Data System (ADS)
de Borniol, E.; Rothman, J.; Salveti, F.; Feautrier, P.
2017-11-01
One of the main challenges of modern astronomical instruments like adaptive optics (AO) systems or fringe trackers is to deal with the very low photons flux detection scenarios. The typical timescale of atmospheric turbulences being in the range of some tens of milliseconds, infrared wavefront sensors for AO systems needs frame rates higher than 1 KHz leading to integration times lower than 1 ms. This integration time associated with a low irradiance results in a few number of integrated photons per frame per pixel. To preserve the information coming from this weak signal, the focal plane array (FPA) has to present a low read out noise, a high quantum efficiency and a low dark current. Up to now, the output noise of high speed near infrared sensors is limited by the silicon read out circuit noise. The use of HgCdTe avalanche photodiodes with high gain at moderate reverse bias and low excess noise seems then a logical way to reduce the impact of the read noise on images signal to noise ratio. These low irradiance passive imaging applications with integration times in the millisecond range needs low photodiode dark current and low background current. These requirements lead to the choice of the photodiode cut off wavelength. The short wave infrared (SWIR) around 3 μm is a good compromise between the gain that can be obtain for a given APD bias and the background and dark current. The CEA LETI HgCdTe APD technology, and a fine analysis of the gain curve characteristic are presented in [1] and won't be detailed here. The response time of the APD is also a key factor for a high frame rate FPA. This parameter has been evaluated in [2] and the results shows cut off frequencies in the GHz range. In this communication we report the performances of a SWIR APD FPA designed and fabricated by CEA LETI and SOFRADIR for astrophysical applications. This development was made in the frame of RAPID, a 4 years R&D project funded by the French FUI (Fond Unique Interministériel). This project involves industrial and academic partners from the field of advanced infrared focal plane arrays fabrication (SOFRADIR and CEA LETI) and of astronomical/defense institutes (IPAG, LAM, ONERA). The goal of this program is to develop a fast and low noise SWIR camera for astronomical fast applications like adaptive optics wavefront sensing and fringe tracking for astronomical interferometers [3]. The first batch of FPA's was based on liquid-phase epitaxy (LPE) grown photodiode arrays with 3 μm cut off wavelength. In order to get higher avalanche gain for a given photodiode reverse bias voltage, we have made a second batch with a cadmium composition leading to 3.3 μm cut off wavelength (λc). This paper described the read out circuit in the next section. The aim section III is to find the critical parameter that has to be measured to evaluate the signal to noise ratio (SNR) of an APD FPA. The main electro optical characteristics of an FPA based on 3.3μm cut off wavelength APDs are reported in "Rapid FPAs characterisation" section. The dark current evolution with temperature of a 3 μm FPA high and low APD bias is also detailed in this section.
Status of backthinned AlGaN based focal plane arrays for deep-UV imaging
NASA Astrophysics Data System (ADS)
Reverchon, J.-L.; Lehoucq, G.; Truffer, J.-P.; Costard, E.; Frayssinet, E.; Semond, F.; Duboz, J.-Y.; Giuliani, A.; Réfrégiers, M.; Idir, M.
2017-11-01
The achievement of deep ultraviolet (UV) focal plane arrays (FPA) is required for both solar physics [1] and micro electronics industry. The success of solar mission (SOHO, STEREO [2], SDO [3]…), has shown the accuracy of imaging at wavelengths from 10 nm to 140 nm to reveal effects occurring in the sun corona. Deep UV steppers at 13 nm are another demanding imaging technology for the microelectronic industry in terms of uniformity and stability. A third application concerns beam shaping of Synchrotron lines [4]. Consequently, such wavelengths are of prime importance whereas the vacuum UV wavelengths are very difficult to detect due to the dramatic interaction of light with materials. The fast development of nitrides has given the opportunity to investigate AlGaN as a material for UV detection. Camera based on AlGaN present an intrinsic spectral selectivity and an extremely low dark current at room temperature. We have previously presented several FPA dedicated to deep UV based on 320 x 256 pixels of Schottky photodiodes with a pitch of 30 μm [4, 5]. AlGaN is grown on a silicon substrate instead of sapphire substrate only transparent down to 200 nm. After a flip-chip hybridization, silicon substrate and AlGaN basal layer was removed by dry etching. Then, the spectral responsivity of the FPA presented a quantum efficiency (QE) from 5% to 20% from 50 nm to 290 nm when removing the highly doped contact layer via a selective wet etching. This FPA suffered from a low uniformity incompatible with imaging, and a long time response due to variations of conductivity in the honeycomb. We also observed a low rejection of visible. It is probably due to the same honeycomb conductivity enhancement for wavelength shorter than 360 nm, i.e., the band gap of GaN. We will show hereafter an improved uniformity due to the use of a precisely ICP (Inductively Coupled Plasma) controlled process. The final membrane thickness is limited to the desertion layer. Neither access resistance limitation nor long response time are observed. QE varies from 5% at 50 nm to 15% at 6 nm (85% more when taking into account the filling factor). Consequently, we can propose prototypes concerning not only "solar blind" camera optimized for narrow band in the near UV range (between 280 nm and 260 nm), but also devices with spectral range extended in the deep UV (290 nm to 10 nm). Both detectors are available for an optical budget evaluation.
Chapinal, Núria; Schumaker, Brant A; Joly, Damien O; Elkin, Brett T; Stephen, Craig
2015-07-01
We estimated the sensitivity and specificity of the caudal-fold skin test (CFT), the fluorescent polarization assay (FPA), and the rapid lateral-flow test (RT) for the detection of Mycobacterium bovis in free-ranging wild wood bison (Bison bison athabascae), in the absence of a gold standard, by using Bayesian analysis, and then used those estimates to forecast the performance of a pairwise combination of tests in parallel. In 1998-99, 212 wood bison from Wood Buffalo National Park (Canada) were tested for M. bovis infection using CFT and two serologic tests (FPA and RT). The sensitivity and specificity of each test were estimated using a three-test, one-population, Bayesian model allowing for conditional dependence between FPA and RT. The sensitivity and specificity of the combination of CFT and each serologic test in parallel were calculated assuming conditional independence. The test performance estimates were influenced by the prior values chosen. However, the rank of tests and combinations of tests based on those estimates remained constant. The CFT was the most sensitive test and the FPA was the least sensitive, whereas RT was the most specific test and CFT was the least specific. In conclusion, given the fact that gold standards for the detection of M. bovis are imperfect and difficult to obtain in the field, Bayesian analysis holds promise as a tool to rank tests and combinations of tests based on their performance. Combining a skin test with an animal-side serologic test, such as RT, increases sensitivity in the detection of M. bovis and is a good approach to enhance disease eradication or control in wild bison.
Providing choices for a marginalized community. A community-based project with Malaysian aborigines.
Kaur, P
1994-01-01
In 1991, the Family Planning Association (FPA) of the Malaysian state of Perak initiated a community-based development project in the remote Aborigine village of Kampung Tisong. The community consists of approximately 34 households who survive on an average income of about US $37. Malnutrition is pervasive, even minor ailments cause death, more serious afflictions are prevalent, and the closest government clinic is 20 kilometers away and seldom used by the Aborigines. 70% of the children have access to education, but parental illiteracy is a serious educational obstacle. The goals of the FPA program are to 1) promote maternal and child health and responsible parenthood, 2) provide health education, 3) encourage women to seek self-determination, and 4) encourage the development of self-reliance in the community as a whole. The first step was to survey the community's culture, beliefs, and health status with the help of the Aborigines Department and the village headman. After a series of preliminary meetings with other agencies, the FPA began to provide activities including health talks, health courses and demonstrations, medical examinations and check-ups, and first aid training. Environmental protection and sanitation measures were included in the educational activities, and following the traditional "mutual aid system," a small plot of land was cleared for vegetable production. Vegetable gardens and needlecraft will become income-producing activities for the women. Attempts to motivate the women to use family planning have been hindered by the fact that the health of 2 women deteriorated after they began using oral contraceptives. Positive changes are occurring slowly and steadily, however, and the FPA has been instrumental in having the settlement included in a program for the hardcore poor which will provide new housing and farming projects.
COUGAR: a liquid nitrogen cooled InGaAs camera for astronomy and electro-luminescence
NASA Astrophysics Data System (ADS)
Van Bogget, Urbain; Vervenne, Vincent; Vinella, Rosa Maria; van der Zanden, Koen; Merken, Patrick; Vermeiren, Jan
2014-06-01
A SWIR FPA was designed and manufactured with 640*512 pixels, 20 μm pitch and InGaAs detectors for electroluminescence characterization and astronomical applications in the [0.9 - 1.55 μm] range. The FPA is mounted in a liquid nitrogen dewar and is operated by a low noise frontend electronics. One of the biggest problem in designing sensors and cameras for electro-luminescence measurements is the autoillumination of the detectors by the readout circuit. Besides of proper shielding of the detectors, the ROIC shall be optimized for minimal electrical activity during the integration time of the very-weak signals coming from the circuit under test. For this reason a SFD (or Source Follower per Detector) architecture (like in the Hawaii sensor) was selected, resulting in a background limited performance of the detector. The pixel has a (somewhat arbitrary) full well capacity of 400 000 e- and a sensitivity of 2.17 μV/e-. The dark signal is app. 1 e-/pixel/sec and with the appropriate Fowler sampling the dark noise lowers below 5 e-rms. The power consumption of the circuit is limited 2 mW, allowing more than 24 hours of operation on less than 1 l of liquid nitrogen. The FPA is equipped with 4 outputs (optional readout on one single channel) and is capable of achieving 3 frames per second. Due to the non-destructive readout it is possible to determine in a dynamic way the optimal integration time for each observation. The Cougar camera is equipped with ultra-low noise power supply and bias lines; the electronics contain also a 24 bit AD converter to fully exploit the sensitivity of the FPA and the camera.
A spatial database of wildfires in the United States, 1992-2011
NASA Astrophysics Data System (ADS)
Short, K. C.
2013-07-01
The statistical analysis of wildfire activity is a critical component of national wildfire planning, operations, and research in the United States (US). However, there are multiple federal, state, and local entities with wildfire protection and reporting responsibilities in the US, and no single, unified system of wildfire record-keeping exists. To conduct even the most rudimentary interagency analyses of wildfire numbers and area burned from the authoritative systems of record, one must harvest records from dozens of disparate databases with inconsistent information content. The onus is then on the user to check for and purge redundant records of the same fire (i.e. multijurisdictional incidents with responses reported by several agencies or departments) after pooling data from different sources. Here we describe our efforts to acquire, standardize, error-check, compile, scrub, and evaluate the completeness of US federal, state, and local wildfire records from 1992-2011 for the national, interagency Fire Program Analysis (FPA) application. The resulting FPA Fire-occurrence Database (FPA FOD) includes nearly 1.6 million records from the 20 yr period, with values for at least the following core data elements: location at least as precise as a Public Land Survey System section (2.6 km2 grid), discovery date, and final fire size. The FPA FOD is publicly available from the Research Data Archive of the US Department of Agriculture, Forest Service (doi:10.2737/RDS-2013-0009). While necessarily incomplete in some aspects, the database is intended to facilitate fairly high-resolution geospatial analysis of US wildfire activity over the past two decades, based on available information from the authoritative systems of record.
A spatial database of wildfires in the United States, 1992-2011
NASA Astrophysics Data System (ADS)
Short, K. C.
2014-01-01
The statistical analysis of wildfire activity is a critical component of national wildfire planning, operations, and research in the United States (US). However, there are multiple federal, state, and local entities with wildfire protection and reporting responsibilities in the US, and no single, unified system of wildfire record keeping exists. To conduct even the most rudimentary interagency analyses of wildfire numbers and area burned from the authoritative systems of record, one must harvest records from dozens of disparate databases with inconsistent information content. The onus is then on the user to check for and purge redundant records of the same fire (i.e., multijurisdictional incidents with responses reported by several agencies or departments) after pooling data from different sources. Here we describe our efforts to acquire, standardize, error-check, compile, scrub, and evaluate the completeness of US federal, state, and local wildfire records from 1992-2011 for the national, interagency Fire Program Analysis (FPA) application. The resulting FPA Fire-Occurrence Database (FPA FOD) includes nearly 1.6 million records from the 20 yr period, with values for at least the following core data elements: location, at least as precise as a Public Land Survey System section (2.6 km2 grid), discovery date, and final fire size. The FPA FOD is publicly available from the Research Data Archive of the US Department of Agriculture, Forest Service (doi:10.2737/RDS-2013-0009). While necessarily incomplete in some aspects, the database is intended to facilitate fairly high-resolution geospatial analysis of US wildfire activity over the past two decades, based on available information from the authoritative systems of record.
Bayerle-Eder, M; Kolodjaschna, J; Wolzt, M; Polska, E; Gasic, S; Schmetterer, L
2005-01-01
Background: The ocular pressure/volume relation, which is described by the Friedenwald equation, forms the basis of intraocular pressure (IOP) measurement with Schiotz tonometry and measurement of pulsatile ocular blood flow (POBF) with pneumotonometry. Changes in intraocular volume during the cardiac cycle are caused by arterial inflow and venous outflow and are accompanied by changes in IOP. The relation between volume and pressure changes is dependent on the elastic properties of the eye coats as described by the ocular rigidity coefficient. Previous studies indicate that there is a vascular contribution to ocular rigidity and that the volume/pressure relationship may depend on the mean arterial pressure. Methods: The effect of a nifedipine induced reduction in systemic blood pressure on pulse amplitude (PA) as assessed with pneumotonometry and fundus pulsation amplitude (FPA), as measured with laser interferometry was investigated in 16 untreated patients with moderate to severe systemic hypertension (mean arterial pressure 123 (SD 12) mm Hg). Results: The ratio between PA and FPA was taken as a measure of the ocular rigidity coefficient. Nifedipine reduced mean arterial pressure by 17.3% and increased pulse rate by 11.0% (p<0.001 each). Whereas PA was significantly reduced after administration of nifedipine (−15.6%; p<0.001), FPA remained unchanged. Accordingly, the ratio of PA/FPA was reduced from 0.86 mm Hg/μm to 0.73 mm Hg/μm after administration of nifedipine. Conclusion: These data are in keeping with previous animal experiments indicating a blood pressure dependent vascular component to the rigidity of the eye coats in vivo. This needs to be taken into account for measurement of IOP with Schiotz tonometry and POBF with pneumotonometry. PMID:15923506
Can We Measure the Heel Bump? Radiographic Evaluation of Haglund's Deformity.
Bulstra, Gythe H; van Rheenen, Thijs A; Scholtes, Vanessa A B
2015-01-01
Haglund's deformity is a symptomatic posterosuperior deformity of the heel. The lateral radiograph of the ankle will show a prominent, large, posterosuperior part of the calcaneus, which can be measured using the Fowler and Philips angle (FPA, the angle between the posterior and plantar surface of the calcaneus) and the calcaneal pitch angle (CPA, the angle between the sole of the foot and the plantar part of the calcaneus). Although these angles are commonly used, these radiographic angle measurements have never shown a relationship with Haglund's deformity. In 78 patients (51% male) with symptomatic Haglund's deformity and a control group of 100 patients (41% male) with no heel complaints, we measured the FPA and CPA on weightbearing lateral radiographs of the foot. Using an unpaired t tests, no significant difference was found between the 2 groups in the FPA (p = .40). We measured a significant difference in the CPA between the Haglund group and the control group (p = .014). Subgroup analysis showed that this difference was mainly found in females (p < .00), with no significant difference seen in the males (p < .48). Females with Haglund's deformity will have a greater CPA than will females without Haglund's deformity. The CPA showed a difference between the Haglund and non-Haglund groups, although mainly in females. Although the evidence from our study is limited, it would be interesting to study the CPA further, because it implicates the verticalization of the calcaneus. This change in position results in extra traction on the Achilles tendon and can eventually cause tendinitis and bursitis. Radiographic measurement should be used as an auxiliary tool. If the calcaneus tends to change position, it would be interesting to understand this process, which could eventually lead to improvement in the treatment of Haglund's deformity. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Gillard, Frédéric; Ferrec, Yann; Guérineau, Nicolas; Rommeluère, Sylvain; Taboury, Jean; Chavel, Pierre
2012-06-01
Stationary Fourier transform spectrometry is an interesting concept for building reliable field or embedded spectroradiometers, especially for the mid- and far- IR. Here, a very compact configuration of a cryogenic stationary Fourier transform IR (FTIR) spectrometer is investigated, where the interferometer is directly integrated in the focal plane array (FPA). We present a theoretical analysis to explain and describe the fringe formation inside the FTIR-FPA structure when illuminated by an extended source positioned at a finite distance from the detection plane. The results are then exploited to propose a simple front lens design compatible with a handheld package.
Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.
Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L
2018-04-01
The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.
A miniature low-cost LWIR camera with a 160×120 microbolometer FPA
NASA Astrophysics Data System (ADS)
Tepegoz, Murat; Kucukkomurler, Alper; Tankut, Firat; Eminoglu, Selim; Akin, Tayfun
2014-06-01
This paper presents the development of a miniature LWIR thermal camera, MSE070D, which targets value performance infrared imaging applications, where a 160x120 CMOS-based microbolometer FPA is utilized. MSE070D features a universal USB interface that can communicate with computers and some particular mobile devices in the market. In addition, it offers high flexibility and mobility with the help of its USB powered nature, eliminating the need for any external power source, thanks to its low-power requirement option. MSE070D provides thermal imaging with its 1.65 inch3 volume with the use of a vacuum packaged CMOS-based microbolometer type thermal sensor MS1670A-VP, achieving moderate performance with a very low production cost. MSE070D allows 30 fps thermal video imaging with the 160x120 FPA size while resulting in an NETD lower than 350 mK with f/1 optics. It is possible to obtain test electronics and software, miniature camera cores, complete Application Programming Interfaces (APIs) and relevant documentation with MSE070D, as MikroSens want to help its customers to evaluate its products and to ensure quick time-to-market for systems manufacturers.
NASA Astrophysics Data System (ADS)
Cao, Yanpeng; Tisse, Christel-Loic
2013-06-01
In uncooled LWIR microbolometer imaging systems, temperature fluctuations of FPA (Focal Plane Array) as well as lens and mechanical components placed along the optical path result in thermal drift and spatial non-uniformity. These non-idealities generate undesirable FPN (Fixed-Pattern-Noise) that is difficult to remove using traditional, individual shutterless and TEC-less (Thermo-Electric Cooling) techniques. In this paper we introduce a novel single-image based processing approach that marries the benefits of both statistical scene-based and calibration-based NUC algorithms, without relying neither on extra temperature reference nor accurate motion estimation, to compensate the resulting temperature-dependent non-uniformities. Our method includes two subsequent image processing steps. Firstly, an empirical behavioral model is derived by calibrations to characterize the spatio-temporal response of the microbolometric FPA to environmental and scene temperature fluctuations. Secondly, we experimentally establish that the FPN component caused by the optics creates a spatio-temporally continuous, low frequency, low-magnitude variation of the image intensity. We propose to make use of this property and learn a prior on the spatial distribution of natural image gradients to infer the correction function for the entire image. The performance and robustness of the proposed temperature-adaptive NUC method are demonstrated by showing results obtained from a 640×512 pixels uncooled LWIR microbolometer imaging system operating over a broad range of temperature and with rapid environmental temperature changes (i.e. from -5°C to 65°C within 10 minutes).
Demosaicking for full motion video 9-band SWIR sensor
NASA Astrophysics Data System (ADS)
Kanaev, Andrey V.; Rawhouser, Marjorie; Kutteruf, Mary R.; Yetzbacher, Michael K.; DePrenger, Michael J.; Novak, Kyle M.; Miller, Corey A.; Miller, Christopher W.
2014-05-01
Short wave infrared (SWIR) spectral imaging systems are vital for Intelligence, Surveillance, and Reconnaissance (ISR) applications because of their abilities to autonomously detect targets and classify materials. Typically the spectral imagers are incapable of providing Full Motion Video (FMV) because of their reliance on line scanning. We enable FMV capability for a SWIR multi-spectral camera by creating a repeating pattern of 3x3 spectral filters on a staring focal plane array (FPA). In this paper we present the imagery from an FMV SWIR camera with nine discrete bands and discuss image processing algorithms necessary for its operation. The main task of image processing in this case is demosaicking of the spectral bands i.e. reconstructing full spectral images with original FPA resolution from spatially subsampled and incomplete spectral data acquired with the choice of filter array pattern. To the best of author's knowledge, the demosaicking algorithms for nine or more equally sampled bands have not been reported before. Moreover all existing algorithms developed for demosaicking visible color filter arrays with less than nine colors assume either certain relationship between the visible colors, which are not valid for SWIR imaging, or presence of one color band with higher sampling rate compared to the rest of the bands, which does not conform to our spectral filter pattern. We will discuss and present results for two novel approaches to demosaicking: interpolation using multi-band edge information and application of multi-frame super-resolution to a single frame resolution enhancement of multi-spectral spatially multiplexed images.
Rotor for processing liquids using movable capillary tubes
Johnson, Wayne F.; Burtis, Carl A.; Walker, William A.
1989-01-01
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.
Rotor for processing liquids using movable capillary tubes
Johnson, Wayne F [Loudon, TN; Burtis, Carl A [Oak Ridge, TN; Walker, William A [Knoxville, TN
1989-05-30
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.
Costigan, M G; Gilchrist, T L; Lindup, W E
1996-06-01
The furan dicarboxylic acid, 3-carboxy-4-methyl-5-propyl-2-furanpropanoic acid (5-propyl FPA) accumulates in the plasma of patients with chronic renal failure and is a major contributor to the drug binding defect of uraemic plasma. This acid has also been implicated in several other aspects of the uraemic syndrome: anaemia, irregularities of thyroid function, neurological symptoms and inhibition of active tubular secretion. The acid is not commercially available and its synthesis, starting with Meldrum's acid and methyl succinyl chloride, is described. The pKa values were measured by titration and values of 3.2 and 3.6 respectively were assigned to the carboxylic acid groups attached directly to the ring at position 3 and at position 2 (on the side-chain). The partition coefficient (log P) between hydrochloric acid and octanol was 1.2 and the distribution coefficient (log D; octanol-phosphate buffer pH 7.4) was -0.59. The pKa values and the degree of hydrophobic character of 5-propyl FPA are consistent with those of other protein-bound acids which undergo active tubular secretion by the kidney and this substance may serve as an endogenous marker for the effects of drugs and disease on this process.
LWIR hyperspectral imager based on a diffractive optics lens
NASA Astrophysics Data System (ADS)
Gupta, Neelam
2009-05-01
A diffractive optics lens based longwave infrared hyperspectral imager has been used to collect laboratory and outdoor field test data. The imager uses a specially designed diffractive optics Ge lens with a 320×256 HgCdTe focal plane array (FPA) cooled with a Sterling-cooler. The imager operates in 8-10.5 μm (long wave IR, LWIR) spectral region and an image cube with 50 to 200 bands can be acquired rapidly. Spectral images at different wavelengths are obtained by moving the lens along its optical axis. An f/2.38 diffractive lens is used with a focal length of 70 mm at 8 μm. The IFOV is 0.57 mrad which corresponds to an FOV of 10.48°. The spectral resolution of the imager is 0.034 μm at 9 μm. The pixel size is 40×40 μm2 in the FPA. In post processing of image cube data contributions due to wavelengths other than the focused one are removed and a correction to account for the change in magnification due to the motion of the lens is applied to each spectral image. A brief description of the imager, data collection and analysis to characterize the performance of the imager will be presented in this paper.
Rotor for processing liquids using movable capillary tubes
Johnson, W.F.; Burtis, C.A.; Walker, W.A.
1987-07-17
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described. 5 figs.
Large size MOEMS Fabry-Perot interferometer filter for focal plane array hyperspectral imaging
NASA Astrophysics Data System (ADS)
Chee, J.; Hwu, J.; Kim, T. S.; Kubby, J.; Velicu, S.; Gupta, N.
2015-02-01
Focal plane array (FPA) technology is mature and is widely used for imaging applications. However, FPAs have broadband responses which limit their ability to provide high performance in hyperspectral applications such as detection of buried explosives, and identifying the presence of explosive chemicals and their concentrations. EPIR is currently developing Micro-Opto-Electro-Mechanical System (MOEMS) Fabry-Perot interferometer filter (FPF) devices for FPAs. In this paper, we present our approach to MOEMS FPF design and fabrication that will meet the size requirements for large format FPA hyperspectral imaging. We also report the performance of our FPF resonance cavity, capable of up to 3 μm change gap in tens of nanometer increments.
Methodology for testing infrared focal plane arrays in simulated nuclear radiation environments
NASA Astrophysics Data System (ADS)
Divita, E. L.; Mills, R. E.; Koch, T. L.; Gordon, M. J.; Wilcox, R. A.; Williams, R. E.
1992-07-01
This paper summarizes test methodology for focal plane array (FPA) testing that can be used for benign (clear) and radiation environments, and describes the use of custom dewars and integrated test equipment in an example environment. The test methodology, consistent with American Society for Testing Materials (ASTM) standards, is presented for the total accumulated gamma dose, transient dose rate, gamma flux, and neutron fluence environments. The merits and limitations of using Cobalt 60 for gamma environment simulations and of using various fast-neutron reactors and neutron sources for neutron simulations are presented. Test result examples are presented to demonstrate test data acquisition and FPA parameter performance under different measurement conditions and environmental simulations.
Forward Propagation Analysis for determining the 16O(n,α)13C Reaction Cross Section at LANSCE
NASA Astrophysics Data System (ADS)
Purcell, Zachary; Lee, Hye Young; Davison, Jacob
2017-09-01
Oxygen is present in many materials and the uncertainties in its nuclear data can have a significant impact on applications. In particular, neutron-absorption reactions reduceavailable neutrons in applications. Thus,high precision in knowledge of this reaction cross sectionis required. To decreasethe systematic uncertainty, we developed a framework that uses Forward Propagation Analysis (FPA) for determining the 16O(n,α)13C reaction cross section from data measured at LANSCE. The Low Energy NZ (LENZ) instrument was used to detectreaction alphas on the Ta2 O5 solid target with silicon strip detectors. The FPA was performed in GEANT4. The geometry, efficiency, and resolution functions of LENZ werevalidated by comparing with the alpha emitting Th-229 source measurement. To reproduce experimental yields in silicon strip detectors, the energy dependent neutron beam flux distribution, the 16O(n,a) reaction differential cross sections, and the 2-body kinematics calculations were implemented in the simulation. We present results from the FPA on LENZ data anddiscuss the improved data analysis [LA-UR-17-26436]. This work has benefited from the use of the Los Alamos Neutron Science Center, is funded by the US Department of Energy and operated by Los Alamos National Security, LLC under Contract DE-AC52-06NA25396.
Sun, Fubao Fuebiol; Hong, Jiapeng; Hu, Jinguang; Saddler, Jack N; Fang, Xu; Zhang, Zhenyu; Shen, Song
2015-11-01
The potential of cellulase enzymes in the developing and ongoing "biorefinery" industry has provided a great motivation to develop an efficient cellulase mixture. Recent work has shown how important the role that the so-called accessory enzymes can play in an effective enzymatic hydrolysis. In this study, three newest Novozymes Cellic CTec cellulase preparations (CTec 1/2/3) were compared to hydrolyze steam pretreated lignocellulosic substrates and model substances at an identical FPA loading. These cellulase preparations were found to display significantly different hydrolytic performances irrelevant with the FPA. And this difference was even observed on the filter paper itself when the FPA based assay was revisited. The analysis of specific enzyme activity in cellulase preparations demonstrated that different accessory enzymes were mainly responsible for the discrepancy of enzymatic hydrolysis between diversified substrates and various cellulases. Such the active role of accessory enzymes present in cellulase preparations was finally verified by supplementation with β-glucosidase, xylanase and lytic polysaccharide monooxygenases AA9. This paper provides new insights into the role of accessory enzymes, which can further provide a useful reference for the rational customization of cellulase cocktails in order to realize an efficient conversion of natural lignocellulosic substrates. Copyright © 2015 Elsevier Inc. All rights reserved.
Optical apparatus for forming correlation spectrometers and optical processors
Butler, Michael A.; Ricco, Antonio J.; Sinclair, Michael B.; Senturia, Stephen D.
1999-01-01
Optical apparatus for forming correlation spectrometers and optical processors. The optical apparatus comprises one or more diffractive optical elements formed on a substrate for receiving light from a source and processing the incident light. The optical apparatus includes an addressing element for alternately addressing each diffractive optical element thereof to produce for one unit of time a first correlation with the incident light, and to produce for a different unit of time a second correlation with the incident light that is different from the first correlation. In preferred embodiments of the invention, the optical apparatus is in the form of a correlation spectrometer; and in other embodiments, the apparatus is in the form of an optical processor. In some embodiments, the optical apparatus comprises a plurality of diffractive optical elements on a common substrate for forming first and second gratings that alternately intercept the incident light for different units of time. In other embodiments, the optical apparatus includes an electrically-programmable diffraction grating that may be alternately switched between a plurality of grating states thereof for processing the incident light. The optical apparatus may be formed, at least in part, by a micromachining process.
Optical apparatus for forming correlation spectrometers and optical processors
Butler, M.A.; Ricco, A.J.; Sinclair, M.B.; Senturia, S.D.
1999-05-18
Optical apparatus is disclosed for forming correlation spectrometers and optical processors. The optical apparatus comprises one or more diffractive optical elements formed on a substrate for receiving light from a source and processing the incident light. The optical apparatus includes an addressing element for alternately addressing each diffractive optical element thereof to produce for one unit of time a first correlation with the incident light, and to produce for a different unit of time a second correlation with the incident light that is different from the first correlation. In preferred embodiments of the invention, the optical apparatus is in the form of a correlation spectrometer; and in other embodiments, the apparatus is in the form of an optical processor. In some embodiments, the optical apparatus comprises a plurality of diffractive optical elements on a common substrate for forming first and second gratings that alternately intercept the incident light for different units of time. In other embodiments, the optical apparatus includes an electrically-programmable diffraction grating that may be alternately switched between a plurality of grating states thereof for processing the incident light. The optical apparatus may be formed, at least in part, by a micromachining process. 24 figs.
Sealed-bladdered chemical processing method and apparatus
Harless, D. Phillip
1999-01-01
A method and apparatus which enables a complete multi-stepped chemical treatment process to occur within a single, sealed-bladdered vessel 31. The entire chemical process occurs without interruption of the sealed-bladdered vessel 31 such as opening the sealed-bladdered vessel 31 between various steps of the process. The sealed-bladdered vessel 31 is loaded with a batch to be dissolved, treated, decanted, rinsed and/or dried. A pressure filtration step may also occur. The self-contained chemical processing apparatus 32 contains a sealed-bladder 32, a fluid pump 34, a reservoir 20, a compressed gas inlet, a vacuum pump 24, and a cold trap 23 as well as the associated piping 33, numerous valves 21,22,25,26,29,30,35,36 and other controls associated with such an apparatus. The claimed invention allows for dissolution and/or chemical treatment without the operator of the self-contained chemical processing apparatus 38 coming into contact with any of the process materials.
Tang, Hongbo; Chen, Hongli; Jia, Yajing; Liu, Xiaoyan; Han, Zhaohong; Wang, Aihua; Liu, Qi; Li, Xinlei; Feng, Xin
2017-01-01
The regular accumulation of nanoparticles in the liver makes them hepatotoxic and decreases the circulation time, thus reducing their therapeutic effect. Resolving this problem will be significant in improving bioavailability and reducing side effects. In this study, we reduced the phagocytosis of epirubicin (EPI)-loaded folic acid-conjugated pullulan acetate (FPA/EPI) nanoparticles by Kupffer cells (KCs) through internalization and nuclear factor kappa B (NF-kB) signal pathway inhibitors, thus allowing development of FPA/EPI nanoparticles as a nanodrug delivery system (NDDS) based on our previous study. FPA/EPI nanoparticles were prepared by the dialysis method. Rat KCs were preincubated with the following individual or compound inhibitors: chlorpromazine (CPZ), nystatin (NY), colchicine (Col), amiloride (AMR), and pyrrolidine dithiocarbamate (PDTC). Dose- and time-dependent cellular uptake effects of inhibitors on FPA/EPI nanoparticles were determined through fluorometry. The cytokine levels of tumor necrosis factor alpha (TNF-α), interleukin-1 beta (IL-1β), and IL-6 were tested in culture supernatants by bead-based multiplex flow cytometry. The uptake study demonstrated that inhibitors had an obvious inhibitory effect ( P <0.05 or P <0.01), with NY, AMR and Col all showing time-dependent inhibitory effects. PDTC + NY had the strongest inhibitory effect, with an uptake rate of 14.62%. The levels of the three proinflammatory cytokines were changed significantly by the compound inhibitors. TNF-α was significantly inhibited ( P <0.05 or P <0.01), but IL-1β and IL-6 showed smaller decreases. These results suggested that clathrin- and caveolae-mediated endocytosis were the main routes via which nanoparticles entered KCs and that the NF-kB signal pathway was very important too. In summary, multiple mechanisms, including clathrin- and caveolae-mediated endocytosis, contribute to cytokine production in macrophages following exposure to folic acid-conjugated pullulan acetate nanoparticles. Thus, the endocytosis inhibition strategy has great potential for improving therapy and reducing toxicity of an NDDS in the treatment of cancer.
Microelectromechanical reciprocating-tooth indexing apparatus
Allen, James J.
1999-01-01
An indexing apparatus is disclosed that can be used to rotate a gear or move a rack in a precise, controllable manner. The indexing apparatus, based on a reciprocating shuttle driven by one or more actuators, can be formed either as a micromachine, or as a millimachine. The reciprocating shuttle of the indexing apparatus can be driven by a thermal, electrostatic or electromagnetic actuator, with one or more wedge-shaped drive teeth of the shuttle being moveable to engage and slide against indexing teeth on the gear or rack, thereby moving the gear or rack. The indexing apparatus can be formed by either surface micromachining processes or LIGA processes, depending on the size of the apparatus that is to be formed.
Space processing experimental apparatus - A survey
NASA Technical Reports Server (NTRS)
Siebel, M. P.
1977-01-01
The processing of materials in a low-g environment was started approximately 10 years ago. This article surveys the apparatus developed during that period. A low-g environment occurs naturally in a free-flying spacecraft (e.g., in manned flights such as Apollo, Skylab, and ASTP); low-g conditions also occur in other free-falling bodies such as sounding rockets and drop tower capsules. Apparatus has been developed for all these craft. Most of the apparatus described serves to melt and resolidify materials in low g; the material may be contained or, by virtue of the environment, freely floating. Other apparatus for separation of intimately mixed components or species is also described. A general conclusion is drawn that the apparatus addresses only a few of the possibilities available, is still at the experimental stage, and is of laboratory scale. It is predicted that processes showing promise will be scaled up to derive economic advantages in the Shuttle era of space flight.
NASA Astrophysics Data System (ADS)
Amory, V.; Lhémery, A.
2008-02-01
Inspection of irregular components is problematical: maladjustment of transducer shoes to surfaces causes aberrations. Flexible phased-arrays (FPAs) designed at CEA LIST to maximize contact are driven by adapted delay laws to compensate for irregularities. Optimizing FPA requires simulation tools. The behavior of one element computed by FEM is observed at the surface and its radiation experimentally validated. Efforts for one element prevent from simulating a FPA by FEM. A model is proposed where each element behaves as nonuniform source of stresses. Exact and asymptotic formulas for Lamb problem are used as convolution kernels for longitudinal, transverse and head waves; the latter is of primary importance for angle-T-beam inspections.
Noise properties of a corner-cube Michelson interferometer LWIR hyperspectral imager
NASA Astrophysics Data System (ADS)
Bergstrom, D.; Renhorn, I.; Svensson, T.; Persson, R.; Hallberg, T.; Lindell, R.; Boreman, G.
2010-04-01
Interferometric hyperspectral imagers using infrared focal plane array (FPA) sensors have received increasing interest within the field of security and defence. Setups are commonly based upon either the Sagnac or the Michelson configuration, where the former is usually preferred due to its mechanical robustness. However, the Michelson configuration shows advantages in larger FOV due to better vignetting performance and improved signal-to-noise ratio and cost reduction due to relaxation of beamsplitter specifications. Recently, a laboratory prototype of a more robust and easy-to-align corner-cube Michelson hyperspectral imager has been demonstrated. The prototype is based upon an uncooled bolometric FPA in the LWIR (8-14 μm) spectral band and in this paper the noise properties of this hyperspectral imager are discussed.
Yoon, R.H.; Adel, G.T.; Luttrell, G.H.
1991-01-01
A method and apparatus are disclosed for the microbubble flotation separation of very fine particles, especially coal, so as to produce a high purity and large recovery efficiently. This is accomplished through the use of a high aspect ratio flotation column, microbubbles, and a countercurrent use of wash water to gently wash the froth. Also, disclosed are unique processes and apparatus for generating microbubbles for flotation in a high efficient and inexpensive manner using either a porous tube or an in-line static generator. 23 figures.
Yoon, Roe-Hoan; Adel, Gregory T.; Luttrell, Gerald H.
1992-01-01
A method and apparatus are disclosed for the microbubble flotation separation of very fine and coarse particles, especially coal and minerals, so as to produce high purity and high recovery efficiency. This is accomplished through the use of a flotation column, microbubbles, recycling of the flotation pulp, and countercurrent wash water to gently wash the froth. Also disclosed are unique processes and apparatus for generating microbubbles for flotation in a highly efficient and inexpensive manner using either a porous tube or in-line static generators.
Yoon, Roe-Hoan; Adel, Gregory T.; Luttrell, Gerald H.
1998-01-01
A method and apparatus are disclosed for the microbubble flotation separation of very fine and coarse particles, especially coal and minerals, so as to produce high purity and high recovery efficiency. This is accomplished through the use of a flotation column, microbubbles, recycling of the flotation pulp, and countercurrent wash water to gently wash the froth. Also disclosed are unique processes and apparatus for generating microbubbles for flotation in a highly efficient and inexpensive manner using either a porous tube or in-line static generators.
Apparatus and processes for the mass production of photovoltaic modules
Barth, Kurt L [Ft. Collins, CO; Enzenroth, Robert A [Fort Collins, CO; Sampath, Walajabad S [Fort Collins, CO
2007-05-22
An apparatus and processes for large scale inline manufacturing of CdTe photovoltaic modules in which all steps, including rapid substrate heating, deposition of CdS, deposition of CdTe, CdCl.sub.2 treatment, and ohmic contact formation, are performed within a single vacuum boundary at modest vacuum pressures. A p+ ohmic contact region is formed by subliming a metal salt onto the CdTe layer. A back electrode is formed by way of a low cost spray process, and module scribing is performed by means of abrasive blasting or mechanical brushing through a mask. The vacuum process apparatus facilitates selective heating of substrates and films, exposure of substrates and films to vapor with minimal vapor leakage, deposition of thin films onto a substrate, and stripping thin films from a substrate. A substrate transport apparatus permits the movement of substrates into and out of vacuum during the thin film deposition processes, while preventing the collection of coatings on the substrate transport apparatus itself.
Apparatus and processes for the mass production of photovotaic modules
Barth, Kurt L.; Enzenroth, Robert A.; Sampath, Walajabad S.
2002-07-23
An apparatus and processes for large scale inline manufacturing of CdTe photovoltaic modules in which all steps, including rapid substrate heating, deposition of CdS, deposition of CdTe, CdCl.sub.2 treatment, and ohmic contact formation, are performed within a single vacuum boundary at modest vacuum pressures. A p+ ohmic contact region is formed by subliming a metal salt onto the CdTe layer. A back electrode is formed by way of a low cost spray process, and module scribing is performed by means of abrasive blasting or mechanical brushing through a mask. The vacuum process apparatus facilitates selective heating of substrates and films, exposure of substrates and films to vapor with minimal vapor leakage, deposition of thin films onto a substrate, and stripping thin films from a substrate. A substrate transport apparatus permits the movement of substrates into and out of vacuum during the thin film deposition processes, while preventing the collection of coatings on the substrate transport apparatus itself.
NASA Astrophysics Data System (ADS)
Khatri, Jaidev
This thesis examines themodeling, analysis, and control system design issues for scramjet powered hypersonic vehicles. A nonlinear three degrees of freedom longitudinal model which includes aero-propulsion-elasticity effects was used for all analyses. This model is based upon classical compressible flow and Euler-Bernouli structural concepts. Higher fidelity computational fluid dynamics and finite element methods are needed for more precise intermediate and final evaluations. The methods presented within this thesis were shown to be useful for guiding initial control relevant design. The model was used to examine the vehicle's static and dynamic characteristics over the vehicle's trimmable region. The vehicle has significant longitudinal coupling between the fuel equivalency ratio (FER) and the flight path angle (FPA). For control system design, a two-input two-output plant (FER - elevator to speed-FPA) with 11 states (including 3 flexible modes) was used. Velocity, FPA, and pitch were assumed to be available for feedback. Aerodynamic heat modeling and design for the assumed TPS was incorporated to original Bolender's model to study the change in static and dynamic properties. De-centralized control stability, feasibility and limitations issues were dealt with the change in TPS elasticity, mass and physical dimension. The impact of elasticity due to TPS mass, TPS physical dimension as well as prolonged heating was also analyzed to understand performance limitations of de-centralized control designed for nominal model.
Solís-Guzmán, María Gloria; Argüello-Astorga, Gerardo; López-Bucio, José; Ruiz-Herrera, León Francisco; López-Meza, Joel; Sánchez-Calderón, Lenin; Carreón-Abud, Yazmín; Martínez-Trujillo, Miguel
2017-01-01
Abstract Proteins of the Split ends (Spen) family are characterized by an N-terminal domain, with one or more RNA recognition motifs and a SPOC domain. In Arabidopsis thaliana, the Spen protein FPA is involved in the control of flowering time as a component of an autonomous pathway independent of photoperiod. The A. thaliana genome encodes another gene for a putative Spen protein at the locus At4g12640, herein named AtSpen2. Bioinformatics analysis of the AtSPEN2 SPOC domain revealed low sequence similarity with the FPA SPOC domain, which was markedly lower than that found in other Spen proteins from unrelated plant species. To provide experimental information about the function of AtSpen2, A. thaliana plants were transformed with gene constructs of its promoter region with uidA::gfp reporter genes; the expression was observed in vascular tissues of leaves and roots, as well as in ovules and developing embryos. There was absence of a notable phenotype in knockout and overexpressing lines, suggesting that its function in plants might be specific to certain endogenous or environmental conditions. Our results suggest that the function of Atspen2 diverged from that of fpa due in part to their different transcription expression pattern and divergence of the regulatory SPOC domain. PMID:28850635
QWIP and third-generation IR imagers
NASA Astrophysics Data System (ADS)
Costard, E.; Bois, Ph.; Marcadet, X.; Nedelcu, A.
2005-10-01
Standard GaAs/AlGaAs Quantum Well Infrared Photodetectors (QWIP) are from now seriously considered for the 3rd generation of IR imagers for military markets. Since 2002, the THALES Group has been manufacturing sensitive arrays using QWIP technology based on AsGa techniques through THALES Research and Technology Laboratory. This QWIP technology allows the realization of large staring arrays for Thermal Imagers (TI) working in the IR band III (8-12 μm). A review of the current QWIP products is presented. In the past researchers claimed many advantages of QWIPs. Uniformity was one of these and is the key parameter for the production start. By presenting our first results of a 640x512 LWIR FPA at a pitch of 20μm we also demonstrate that very high performances can be achieved even with small pixels which opens the field for the realization of usable and affordable megapixel FPAs. Another advantage widely claimed in the past for QWIPs was the so-called band-gap engineering and versatility of the III-V processing allowing the custom design of quantum structure to fulfill the requirements of specific applications like very long wavelength (VLWIR) or multispectral detection. In this presentation, we present the performances of our first 256x256 MWIR / LWIR two color FPA at a pitch of 25 μm, and also the current status of QWIPs for VLWIR arrays (>15μm).
Improved calibration-based non-uniformity correction method for uncooled infrared camera
NASA Astrophysics Data System (ADS)
Liu, Chengwei; Sui, Xiubao
2017-08-01
With the latest improvements of microbolometer focal plane arrays (FPA), uncooled infrared (IR) cameras are becoming the most widely used devices in thermography, especially in handheld devices. However the influences derived from changing ambient condition and the non-uniform response of the sensors make it more difficult to correct the nonuniformity of uncooled infrared camera. In this paper, based on the infrared radiation characteristic in the TEC-less uncooled infrared camera, a novel model was proposed for calibration-based non-uniformity correction (NUC). In this model, we introduce the FPA temperature, together with the responses of microbolometer under different ambient temperature to calculate the correction parameters. Based on the proposed model, we can work out the correction parameters with the calibration measurements under controlled ambient condition and uniform blackbody. All correction parameters can be determined after the calibration process and then be used to correct the non-uniformity of the infrared camera in real time. This paper presents the detail of the compensation procedure and the performance of the proposed calibration-based non-uniformity correction method. And our method was evaluated on realistic IR images obtained by a 384x288 pixels uncooled long wave infrared (LWIR) camera operated under changed ambient condition. The results show that our method can exclude the influence caused by the changed ambient condition, and ensure that the infrared camera has a stable performance.
Development of a 1K x 1K GaAs QWIP Far IR Imaging Array
NASA Technical Reports Server (NTRS)
Jhabvala, M.; Choi, K.; Goldberg, A.; La, A.; Gunapala, S.
2003-01-01
In the on-going evolution of GaAs Quantum Well Infrared Photodetectors (QWIPs) we have developed a 1,024 x 1,024 (1K x1K), 8.4-9 microns infrared focal plane array (FPA). This 1 megapixel detector array is a hybrid using the Rockwell TCM 8050 silicon readout integrated circuit (ROIC) bump bonded to a GaAs QWIP array fabricated jointly by engineers at the Goddard Space Flight Center (GSFC) and the Army Research Laboratory (ARL). The finished hybrid is thinned at the Jet Propulsion Lab. Prior to this development the largest format array was a 512 x 640 FPA. We have integrated the 1K x 1K array into an imaging camera system and performed tests over the 40K-90K temperature range achieving BLIP performance at an operating temperature of 76K (f/2 camera system). The GaAs array is relatively easy to fabricate once the superlattice structure of the quantum wells has been defined and grown. The overall arrays costs are currently dominated by the costs associated with the silicon readout since the GaAs array fabrication is based on high yield, well-established GaAs processing capabilities. In this paper we will present the first results of our 1K x 1K QWIP array development including fabrication methodology, test data and our imaging results.
Process for producing an activated carbon adsorbent with integral heat transfer apparatus
NASA Technical Reports Server (NTRS)
Jones, Jack A. (Inventor); Yavrouian, Andre H. (Inventor)
1996-01-01
A process for producing an integral adsorbent-heat exchanger apparatus useful in ammonia refrigerant heat pump systems. In one embodiment, the process wets an activated carbon particles-solvent mixture with a binder-solvent mixture, presses the binder wetted activated carbon mixture on a metal tube surface and thereafter pyrolyzes the mixture to form a bonded activated carbon matrix adjoined to the tube surface. The integral apparatus can be easily and inexpensively produced by the process in large quantities.
Holloway, Aleksey
1992-01-07
The present invention discloses a process and apparatus for forming textures in materials. The process comprises heating a material having an anisotropy in the paramagnetic or diamagnetic susceptibility within a magnetic field. The material is heated to a temperature approaching its melting point while a magnetic field of at least 10.sup.4 Oe is simultaneously applied. The process and apparatus produce highly textured bulk and elongated materials with high current densities below critical superconducting temperatures.
Holloway, A.
1992-01-07
The present invention discloses a process and apparatus for forming textures in materials. The process comprises heating a material having an anisotropy in the paramagnetic or diamagnetic susceptibility within a magnetic field. The material is heated to a temperature approaching its melting point while a magnetic field of at least 10[sup 4]Oe is simultaneously applied. The process and apparatus produce highly textured bulk and elongated materials with high current densities below critical superconducting temperatures. 6 figs.
Grinding assembly, grinding apparatus, weld joint defect repair system, and methods
Larsen, Eric D.; Watkins, Arthur D.; Bitsoi, Rodney J.; Pace, David P.
2005-09-27
A grinding assembly for grinding a weld joint of a workpiece includes a grinder apparatus, a grinder apparatus includes a grinding wheel configured to grind the weld joint, a member configured to receive the grinding wheel, the member being configured to be removably attached to the grinder apparatus, and a sensor assembly configured to detect a contact between the grinding wheel and the workpiece. The grinding assembly also includes a processing circuitry in communication with the grinder apparatus and configured to control operations of the grinder apparatus, the processing circuitry configured to receive weld defect information of the weld joint from an inspection assembly to create a contour grinding profile to grind the weld joint in a predetermined shape based on the received weld defect information, and a manipulator having an end configured to carry the grinder apparatus, the manipulator further configured to operate in multiple dimensions.
Yoon, R.H.; Adel, G.T.; Luttrell, G.H.
1992-12-01
A method and apparatus are disclosed for the microbubble flotation separation of very fine and coarse particles, especially coal and minerals, so as to produce high purity and high recovery efficiency. This is accomplished through the use of a flotation column, microbubbles, recycling of the flotation pulp, and countercurrent wash water to gently wash the froth. Also disclosed are unique processes and apparatus for generating microbubbles for flotation in a highly efficient and inexpensive manner using either a porous tube or in-line static generators. 14 figs.
Yoon, R.H.; Adel, G.T.; Luttrell, G.H.
1998-09-29
A method and apparatus are disclosed for the microbubble flotation separation of very fine and coarse particles, especially coal and minerals, so as to produce high purity and high recovery efficiency. This is accomplished through the use of a flotation column, microbubbles, recycling of the flotation pulp, and countercurrent wash water to gently wash the froth. Also disclosed are unique processes and apparatus for generating microbubbles for flotation in a highly efficient and inexpensive manner using either a porous tube or in-line static generators. 14 figs.
Generalized algebraic scene-based nonuniformity correction algorithm.
Ratliff, Bradley M; Hayat, Majeed M; Tyo, J Scott
2005-02-01
A generalization of a recently developed algebraic scene-based nonuniformity correction algorithm for focal plane array (FPA) sensors is presented. The new technique uses pairs of image frames exhibiting arbitrary one- or two-dimensional translational motion to compute compensator quantities that are then used to remove nonuniformity in the bias of the FPA response. Unlike its predecessor, the generalization does not require the use of either a blackbody calibration target or a shutter. The algorithm has a low computational overhead, lending itself to real-time hardware implementation. The high-quality correction ability of this technique is demonstrated through application to real IR data from both cooled and uncooled infrared FPAs. A theoretical and experimental error analysis is performed to study the accuracy of the bias compensator estimates in the presence of two main sources of error.
Modeling Charge Collection in Detector Arrays
NASA Technical Reports Server (NTRS)
Hardage, Donna (Technical Monitor); Pickel, J. C.
2003-01-01
A detector array charge collection model has been developed for use as an engineering tool to aid in the design of optical sensor missions for operation in the space radiation environment. This model is an enhancement of the prototype array charge collection model that was developed for the Next Generation Space Telescope (NGST) program. The primary enhancements were accounting for drift-assisted diffusion by Monte Carlo modeling techniques and implementing the modeling approaches in a windows-based code. The modeling is concerned with integrated charge collection within discrete pixels in the focal plane array (FPA), with high fidelity spatial resolution. It is applicable to all detector geometries including monolithc charge coupled devices (CCDs), Active Pixel Sensors (APS) and hybrid FPA geometries based on a detector array bump-bonded to a readout integrated circuit (ROIC).
Jamison, J M; Fourie, E; Siper, P M; Trelles, M P; George-Jones, Julia; Buxbaum Grice, A; Krata, J; Holl, E; Shaoul, J; Hernandez, B; Mitchell, L; McKay, M M; Buxbaum, J D; Kolevzon, Alexander
2017-05-01
Autism spectrum disorder (ASD) affects individuals across all racial and ethnic groups, yet rates of diagnosis are disproportionately higher for Black and Hispanic children. Caregivers of children with ASD experience significant stressors, which have been associated with parental strain, inadequate utilization of mental health services and lower quality of life. The family peer advocate (FPA) model has been utilized across service delivery systems to provide family-to-family support, facilitate engagement, and increase access to care. This study used a randomized controlled design to examine the efficacy of FPAs in a racially and ethnically diverse sample. Results demonstrate significantly increased knowledge of ASD and reduced levels of stress for caregivers who received the FPA intervention as compared to treatment as usual.
Subelectron readout noise focal plane arrays for space imaging
NASA Astrophysics Data System (ADS)
Atlas, Gene; Wadsworth, Mark
2004-01-01
Readout noise levels of under 1 electron have long been a goal for the FPA community. In the quest to enhance the FPA sensitivity, various approaches have been attempted ranging from the exotic Photo-multiplier tubes, Image Intensifier tubes, Avalanche photo diodes, and now the on-chip avalanche charge amplification technologies from the CCD manufacturers. While these techniques reduce the readout noise, each offers a set of compromises that negatively affect the overall performance of the sensor in parameters such as power dissipation, dynamic range, uniformity or system complexity. In this work, we overview the benefits and tradeoffs of each approach, and introduce a new technique based on ImagerLabs" exclusive HIT technology which promises sub-electron read noise and other benefits without the tradeoffs of the other noise reduction techniques.
Sources and Implications of Bias and Uncertainty in a Century of US Wildfire Activity Data
NASA Astrophysics Data System (ADS)
Short, K.
2013-12-01
The statistical analysis of wildfire activity is a critical component of national wildfire planning, operations, and research in the United States (US). Wildfire activity data have been collected in the US for over a century. Yet, to this day, no single unified system of wildfire record-keeping exists. Data for analysis are generally harvested from archival summary reports from federal or interagency fire organizations; incident-level wildfire reporting systems of the federal, state, and local fire services; and, increasingly, remote-sensing programs. It is typical for research into wildfire activity patterns for all or part of the last century to require data from several of these sources and perhaps others. That work is complicated by the disunity of the various datasets and potentially compromised by inherent reporting biases, discussed here. The availability of wildfire records with the information content and geospatial precision generally sought for increasingly popular climatological analyses and the modeling of contemporary wildfire risk is limited to recent decades. We explain how the disunity and idiosyncrasies of US wildfire reporting have largely precluded true interagency, or all-lands, analyses of even recent wildfire activity and hamstrung some early risk modeling efforts. We then describe our efforts to acquire, standardize, error-check, compile, scrub, and evaluate the completeness of US federal, state, and local wildfire records from 1992-2011 for the national interagency Fire Program Analysis (FPA) application. The resulting FPA Fire-Occurrence Database (FPA FOD) includes nearly 1.6 million records from the 20-year period, with values for at least the following core data elements: location at least as precise as a Public Land Survey System section (2.6-km2 grid), discovery date, and final fire size. The FPA FOD is publicly available from the Research Data Archive of the US Department of Agriculture, Forest Service (http://dx.doi.org/10.2737/RDS-2013-0009). While necessarily incomplete in some aspects, the database is intended to facilitate fairly high-resolution geospatial analysis of wildfire activity over the past two decades, based on available information from the authoritative systems of record. Formal non-federal wildfire reporting has been on the rise over the past several decades, and users of national datasets like the FPA FOD must beware of state and local reporting biases to avoid drawing spurious conclusions when analysing the data. Apparent trends in the numbers and area burned by wildfires, for example, may be the result of multiple factors, including changes in climate, fuels, demographics (e.g. population density), fire-management policies, and - as we underscore here - levels of reporting.
Brniak, Witold; Jachowicz, Renata; Krupa, Anna; Skorka, Tomasz; Niwinski, Krzysztof
2013-01-01
The compendial method of evaluation of orodispersible tablets (ODT) is the same disintegration test as for conventional tablets. Since it does not reflect the disintegration process in the oral cavity, alternative methods are proposed that are more related to in vivo conditions, e.g. modified dissolution paddle apparatus, texture analyzer, rotating shaft apparatus, CCD camera application, or wetting time and water absorption ratio measurement. In this study, three different co-processed excipients for direct compression of orally disintegrating tablets were compared (Ludiflash, Pharmaburst, F-Melt). The properties of the prepared tablets such as tensile strength, friability, wetting time and water absorption ratio were evaluated. Disintegration time was measured using the pharmacopoeial method and the novel apparatus constructed by the authors. The apparatus was based on the idea of Narazaki et al., however it has been modified. Magnetic resonance imaging (MRI) was applied for the analysis of the disintegration mechanism of prepared tablets. The research has shown the significant effect of excipients, compression force, temperature, volume and kind of medium on the disintegration process. The novel apparatus features better correlation of disintegration time with in vivo results (R(2) = 0.9999) than the compendial method (R(2) = 0.5788), and presents additional information on the disintegration process, e.g. swelling properties.
Optical Imaging and Radiometric Modeling and Simulation
NASA Technical Reports Server (NTRS)
Ha, Kong Q.; Fitzmaurice, Michael W.; Moiser, Gary E.; Howard, Joseph M.; Le, Chi M.
2010-01-01
OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge diffusion modulation transfer function (MTF).
Keshinro, Oluremi Olufunke
2012-01-01
The objective of this study was to determine protein quality and hematological properties of infant diets formulated from local food materials. The food materials were obtained locally, fermented, and milled into flour. The flours were mixed as 70% popcorn and 30% African locust bean (FPA), 70% popcorn and 30% bambara groundnut (FPB), and 70% popcorn, 20% bambara groundnut, and 10% African locust bean (FPAB). Proximate analysis, protein quality, hematological properties, and anthropometric measurements of the animals fed with the formulations were investigated. The protein contents of the formulated diets were significantly higher than that of Cerelac (a commercial preparation) (15.75 ± 0.01 g/100 g) and ogi (traditional complementary food) (6.52 ± 0.31 g/100 g). The energy value of FPAB (464.94 ± 1.22 kcal) was higher than those of FPA (441.41 ± 3.05 kcal) and FPB (441.48 ± 3.05 kcal). The biological value (BV) of FPAB (60.20%) was the highest followed by FPB (44.24%) and FPA (41.15%); however, BV of the diets was higher than that of ogi (10.03%) but lower than that of Cerelac (70.43%). Net protein utilization (NPU) of the formulations was 41.16-60.20%, whereas true protein digestibility was 41.05-60.05%. Metabolizable energy (232.98 kcal) and digestible energy (83.69 kcal) of FPAB were the highest, whereas that of FPA had the lowest values. The protein digestibility values corrected for amino acid score of the diets (0.22-0.44) were lower than that of Cerelac (0.52), but higher than that of ogi (0.21). The growth patterns and hematological properties (packed cell volume, red blood cells, hemoglobin, mean corpuscular hemoglobin concentration, mean corpuscular hemoglobin, and mean corpuscular volume) of the formulated diets were higher than those of ogi, but lower than those of Cerelac. In conclusion, we established that the FPAB food sample was rated best in terms of protein quality over the other formulated diets. Therefore, a FPAB blend may be used as a substitute for ogi. PMID:23198016
Ijarotimi, Oluwole Steve; Keshinro, Oluremi Olufunke
2012-10-01
The objective of this study was to determine protein quality and hematological properties of infant diets formulated from local food materials. The food materials were obtained locally, fermented, and milled into flour. The flours were mixed as 70% popcorn and 30% African locust bean (FPA), 70% popcorn and 30% bambara groundnut (FPB), and 70% popcorn, 20% bambara groundnut, and 10% African locust bean (FPAB). Proximate analysis, protein quality, hematological properties, and anthropometric measurements of the animals fed with the formulations were investigated. The protein contents of the formulated diets were significantly higher than that of Cerelac (a commercial preparation) (15.75 ± 0.01 g/100 g) and ogi (traditional complementary food) (6.52 ± 0.31 g/100 g). The energy value of FPAB (464.94 ± 1.22 kcal) was higher than those of FPA (441.41 ± 3.05 kcal) and FPB (441.48 ± 3.05 kcal). The biological value (BV) of FPAB (60.20%) was the highest followed by FPB (44.24%) and FPA (41.15%); however, BV of the diets was higher than that of ogi (10.03%) but lower than that of Cerelac (70.43%). Net protein utilization (NPU) of the formulations was 41.16-60.20%, whereas true protein digestibility was 41.05-60.05%. Metabolizable energy (232.98 kcal) and digestible energy (83.69 kcal) of FPAB were the highest, whereas that of FPA had the lowest values. The protein digestibility values corrected for amino acid score of the diets (0.22-0.44) were lower than that of Cerelac (0.52), but higher than that of ogi (0.21). The growth patterns and hematological properties (packed cell volume, red blood cells, hemoglobin, mean corpuscular hemoglobin concentration, mean corpuscular hemoglobin, and mean corpuscular volume) of the formulated diets were higher than those of ogi, but lower than those of Cerelac. In conclusion, we established that the FPAB food sample was rated best in terms of protein quality over the other formulated diets. Therefore, a FPAB blend may be used as a substitute for ogi.
Shury, Todd K; Bergeson, Doug; Surujballi, Om; Lyashchenko, Konstantin P; Greenwald, Rena
2014-08-01
Diagnosis of Mycobacterium bovis in wild populations is very challenging due to complications imposed by the use of traditional skin tests, poor sensitivity of gold standard tests which rely on culture of M. bovis from tissues and wide variations in severity of disease. Various combinations of a lymphocyte stimulation test (LST), fluorescence polarization assay (FPA) and the Cervid TB Stat-Pak were evaluated using two different validation approaches: a latent class analysis and classical statistical approach using culture as a gold standard. A validation subsample consisting of animals culled for population control and mortalities from capture provided an unbiased estimate of test performance for comparison. The sensitivity of the LST (0.83, 95% CI: [0.70-0.97] as a single test was similar to existing tuberculin skin tests, but the sensitivity of the FPA (0.40, 95% CI: [0.22-0.58]) and Cervid TB Stat-Pak (0.62, 95% CI: [0.41-0.83]) were lower in this population. Test performance of the LST and Cervid TB Stat-Pak in parallel was similar to the use of all three tests in parallel and inclusion of the FPA did not greatly enhance test performance. Prevalence of M. bovis in elk varied substantially between the high risk area of southern Manitoba (9.1%, 95% CI: [6.09-12.1%]) and lower risk areas outside this zone (0.76%, 95% CI: [0-2.26%]). Bayesian latent class analysis indicated lack of covariance between the two antibody tests (FPA and Cervid TB Stat-Pak) while the classical two-stage analysis indicated there was conditional dependence between the tests. All three tests when used in parallel resulted in 100% NPV using all three validation methods, indicating few elk were misclassified as false negative by post mortem culture. Similar to previous studies, this study found that combinations of blood tests that utilize cell mediated responses along with humoral antibody responses maximize the sensitivity of tests for diagnosis of M. bovis in wild cervid populations. Copyright © 2013 CROWN COPYRIGHT and Elsevier B.V. Published by Elsevier B.V. All rights reserved.
Discussion about photodiode architectures for space applications
NASA Astrophysics Data System (ADS)
Gravrand, O.; Destefanis, G.; Cervera, C.; Zanatta, J.-P.; Baier, N.; Ferron, A.; Boulade, O.
2017-11-01
Detection for space application is very demanding on the IR detector: all wavelengths, from visible-NIR (2- 3um cutoff) to LWIR (10-12.5um cutoff), even sometimes VLWIR (15um cutoff) may be of interest. Moreover, various scenarii are usually considered. Some are imaging applications where the focal plane array (FPA) is used as an optical element to sense an image. However, the FPA may also be used in spectrometric applications where light is triggered on the different pixels depending on its wavelength. In some cases, star pointing is another use of FPAs where the retina is used to sense the position of the satellite. In all those configurations, we might distinguish several categories of applications: • low flux applications where the FPA is staring at space and the detection occurs with only a few number of photons. • high flux applications where the FPA is usually staring at the earth. In this case, the black body emission of the earth and its atmosphere ensures usually a large number of photons to perform the detection. Those two different categories are highly dimensioning for the detector as it usually determines the level of dark current and quantum efficiency (QE) requirements. Indeed, high detection performance usually requires a large number of integrated photons such that high QE is needed for low flux applications, in order to limit the integration time as much as possible. Moreover, dark current requirement is also directly linked to the expected incoming flux, in order to limit as much as possible the SNR degradation due to dark charges vs photocharges. Note that in most cases, this dark current is highly depending on operating temperature which dominates detector consumption. A classical way to mitigate dark current is to cool down the detector to very low temperatures. This paper won't discuss the need for wavefront sensing where the number of detected photons is low because of a very narrow integration window. Rigorously, this kind of configuration is a low flux application but the need for speed distinguishes it from other low flux applications as it usually requires a different ROIC architecture and a photodiode optimized for high response speed.
Pulse combusted acoustic agglomeration apparatus and process
Mansour, Momtaz N.; Chandran, Ravi
1994-01-01
An improved apparatus and process for removal of particulates entrained in a gas stream are provided. The removal process employs a pulse combustor to provide an acoustic pressure wave to acoustically enhance agglomeration of particulates which may be collected and removed using a conventional separation apparatus. The apparatus may be employed as a direct fired system for improved operation of gas-operated equipment such as a gas turbine, or may, alternatively, be employed as an add-on subsystem for combustion exhaust clean-up. Additionally, added particulates may include a sorbent for effecting sorption of other contaminants such as sulfur. Various other particulates for contaminant removal may also be introduced into the system as exemplified by alkali-gettering agents.
Apparatus and process for passivating an SRF cavity
Myneni, Ganapati Rao; Wallace, John P
2014-12-02
An apparatus and process for the production of a niobium cavity exhibiting high quality factors at high gradients is provided. The apparatus comprises a first chamber positioned within a second chamber, an RF generator and vacuum pumping systems. The process comprises placing the niobium cavity in a first chamber of the apparatus; thermally treating the cavity by high temperature in the first chamber while maintaining high vacuum in the first and second chambers; and applying a passivating thin film layer to a surface of the cavity in the presence of a gaseous mixture and an RF field. Further a niobium cavity exhibiting high quality factors at high gradients produced by the method of the invention is provided.
Support apparatus for semiconductor wafer processing
Griffiths, Stewart K.; Nilson, Robert H.; Torres, Kenneth J.
2003-06-10
A support apparatus for minimizing gravitational stress in semiconductor wafers, and particularly silicon wafers, during thermal processing. The support apparatus comprises two concentric circular support structures disposed on a common support fixture. The two concentric circular support structures, located generally at between 10 and 70% and 70 and 100% and preferably at 35 and 82.3% of the semiconductor wafer radius, can be either solid rings or a plurality of spaced support points spaced apart from each other in a substantially uniform manner. Further, the support structures can have segments removed to facilitate wafer loading and unloading. In order to withstand the elevated temperatures encountered during semiconductor wafer processing, the support apparatus, including the concentric circular support structures and support fixture can be fabricated from refractory materials, such as silicon carbide, quartz and graphite. The claimed wafer support apparatus can be readily adapted for use in either batch or single-wafer processors.
NASA Astrophysics Data System (ADS)
Carson, John C.
1990-11-01
Various papers on materials, devices, techniques, and applications for X-plane focal plane array technology are presented. Individual topics addressed include: application of Z-plane technology to the remote sensing of the earth from GEO, applications of smart neuromorphic focal planes, image-processing of Z-plane technology, neural network Z-plane implementation with very high interconnection rates, using a small IR surveillance satellite for tactical applications, establishing requirements for homing applications, Z-plane technology. Also discussed are: on-array spike suppression signal processing, algorithms for on-focal-plane gamma circumvention and time-delay integration, current HYMOSS Z-technology, packaging of electrons for on- and off-FPA signal processing, space/performance qualification of tape automated bonded devices, automation in tape automated bonding, high-speed/high-volume radiometric testing of Z-technology focal planes, 128-layer HYMOSS-module fabrication issues, automation of IRFPA production processes.
Infrared readout electronics; Proceedings of the Meeting, Orlando, FL, Apr. 21, 22, 1992
NASA Technical Reports Server (NTRS)
Fossum, Eric R. (Editor)
1992-01-01
The present volume on IR readout electronics discusses cryogenic readout using silicon devices, cryogenic readout using III-V and LTS devices, multiplexers for higher temperatures, and focal-plane signal processing electronics. Attention is given to the optimization of cryogenic CMOS processes for sub-10-K applications, cryogenic measurements of aerojet GaAs n-JFETs, inP-based heterostructure device technology for ultracold readout applications, and a three-terminal semiconductor-superconductor transimpedance amplifier. Topics addressed include unfulfilled needs in IR astronomy focal-plane readout electronics, IR readout integrated circuit technology for tactical missile systems, and radiation-hardened 10-bit A/D for FPA signal processing. Also discussed are the implementation of a noise reduction circuit for spaceflight IR spectrometers, a real-time processor for staring receivers, and a fiber-optic link design for INMOS transputers.
Apparatus and method for fluid analysis
Wilson, Bary W.; Peters, Timothy J.; Shepard, Chester L.; Reeves, James H.
2004-11-02
The present invention is an apparatus and method for analyzing a fluid used in a machine or in an industrial process line. The apparatus has at least one meter placed proximate the machine or process line and in contact with the machine or process fluid for measuring at least one parameter related to the fluid. The at least one parameter is a standard laboratory analysis parameter. The at least one meter includes but is not limited to viscometer, element meter, optical meter, particulate meter, and combinations thereof.
Apparatus and process for controlling fluidized beds
Rehmat, Amirali G.; Patel, Jitendra G.
1985-10-01
An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.
Status of LWIR HgCdTe infrared detector technology
NASA Technical Reports Server (NTRS)
Reine, M. B.
1990-01-01
The performance requirements that today's advanced Long Wavelength Infrared (LWIR) focal plane arrays place on the HgCdTe photovoltaic detector array are summarized. The theoretical performance limits for intrinsic LWIR HgCdTe detectors are reviewed as functions of cutoff wavelength and operating temperature. The status of LWIR HgCdTe photovoltaic detectors is reviewed and compared to the focal plane array (FPA) requirements and to the theoretical limits. Emphasis is placed on recent data for two-layer HgCdTe PLE heterojunction photodiodes grown at Loral with cutoff wavelengths ranging between 10 and 19 microns at temperatures of 70 to 80 K. Development trends in LWIR HgCdTe detector technology are outlined, and conclusions are drawn about the ability for photovoltaic HgCdTe detector arrays to satisfy a wide variety of advanced FPA array applications.
The 640 × 512 LWIR type-II superlattice detectors operating at 110 K
NASA Astrophysics Data System (ADS)
Tan, Bi-Song; Zhang, Chuan-Jie; Zhou, Wen-Hong; Yang, Xiao-Jie; Wang, Guo-Wei; Li, Yun-Tao; Ding, Yan-Yan; Zhang, Zhou; Lei, Hua-Wei; Liu, Wei-Hua; Du, Yu; Zhang, Li-Fang; Liu, Bin; Wang, Li-Bao; Huang, Li
2018-03-01
The type-II InAs/GaSb superlattices (T2SLs)-based 640 × 512 long wavelength infrared (LWIR) Focal Plane Array (FPA) detector with15 μm pitch and 50% cut-off wavelength of 10.5 μm demonstrates a peak quantum efficiency of 38.6% and peak detectivity of 1.65 × 1011 cm Hz1/2 W-1 at 8.1 μm, high pixel operability of 99.5% and low responsivity non-uniformity of 2.69% at 80 K. The FPA exhibits clear infrared imaging at 110 K and diffusion-limited dark current densities below Tennant's 'Rule07' at temperature above 100 K, which is attributed to the efficient suppression of diffusion dark current and surface leak current by introducing M-structure barrier and double hetero-structure passivation layers.
High-Performance LWIR Superlattice Detectors and FPA Based on CBIRD Design
NASA Technical Reports Server (NTRS)
Soibel, Alexander; Nguyen, Jean; Rafol, Sir B.; Liao, Anna; Hoeglund, Linda; Khoshakhlagh, Arezou; Keo, Sam A.; Mumolo, Jason M.; Liu, John; Ting, David Z.-Y.;
2011-01-01
We report our recent efforts on advancing of antimonide superlattice based infrared photodetectors and demonstration of focal plane arrays based on a complementary barrier infrared detector (CBIRD) design. By optimizing design and growth condition we succeeded to reduce the operational bias of CBIRD single pixel detector without increase of dark current or degradation of quantum efficiency. We demonstrated a 1024x1024 pixel long-wavelength infrared focal plane array utilizing CBIRD design. An 11.5 micrometer cutoff focal plane without anti-reflection coating has yielded noise equivalent differential temperature of 53 mK at operating temperature of 80 K, with 300 K background and cold-stop. Imaging results from a recent 10 micrometer cutoff focal plane array are also presented. These results advance state-of-the art of superlattice detectors and demonstrated advantages of CBIRD architecture for realization of FPA.
High-Performance LWIR Superlattice Detectors and FPA Based on CBIRD Design
NASA Technical Reports Server (NTRS)
Soibel, Alexander; Nguyen, Jean; Rafol, Sir B.; Liao, Anna; Hoeglund, Linda; Khoshakhlagh, Arezou; Keo, Sam A.; Mumolo, Jason M.; Liu, John; Ting, David Z.-Y.;
2011-01-01
We report our recent efforts on advancing of antimonide superlattice based infrared photodetectors and demonstration of focal plane arrays based on a complementary barrier infrared detector (CBIRD) design. By optimizing design and growth condition we succeeded to reduce the operational bias of CBIRD single pixel detector without increase of dark current or degradation of quantum efficiency. We demonstrated a 1024x1024 pixel long-waveleng thinfrared focal plane array utilizing CBIRD design. An 11.5 micrometer cutoff focal plane without anti-reflection coating has yielded noise equivalent differential temperature of 53 mK at operating temperature of 80 K, with 300 K background and cold-stop. Imaging results from a recent 10 micrometer cutoff focal plane array are also presented. These results advance state-of-the art of superlattice detectors and demonstrated advantages of CBIRD architecture for realization of FPA.
Improvements of MCT MBE Growth on GaAs
NASA Astrophysics Data System (ADS)
Ziegler, J.; Wenisch, J.; Breiter, R.; Eich, D.; Figgemeier, H.; Fries, P.; Lutz, H.; Wollrab, R.
2014-08-01
In recent years, continuous progress has been published in the development of HgCdTe (MCT) infrared (IR) focal plane arrays (FPAs) fabricated by molecular beam epitaxy on GaAs substrates. In this publication, further characterization of the state-of-the art 1280 × 1024 pixel, 15- μm pitch detector fabricated from this material in both the mid-wavelength (MWIR) and long-wavelength (LWIR) IR region will be presented. For MWIR FPAs, the percentage of defective pixel remains below 0.5% up to an operating temperature ( T OP) of around 100 K. For the LWIR FPA, an operability of 99.25% was achieved for a T OP of 76 K. Additionally, the beneficial effect of the inclusion of MCT layers with a graded composition region was investigated and demonstrated on current-voltage ( IV) characteristics on test diodes in a MWIR FPA.
Quantum well infrared photodetector simultaneously working in the two atmospheric windows
NASA Astrophysics Data System (ADS)
Huo, Y. H.; Ma, W. Q.; Zhang, Y. H.; Chong, M.; Yang, T.; Chen, L. H.; Shi, Y. L.
2009-07-01
We have demonstrated a dual-band quantum well infrared photodetector (QWIP) exhibiting simultaneous photoresponse both in the mid and the long wavelength atmospheric windows of 3-5 μm and of 8-12 μm, but the device only has two ohmic contacts. The structure of the device was achieved by sequentially growing a mid wavelength part (MWQWIP) followed by a long wavelength part (LWQWIP) separated by an n+ layer. Comparing with the conventional dual-band QWIP device utilizing three ohmic contacts, our QWIP is promising to greatly facilitate the two-color focal plane array (FPA) fabrication by reducing the number of the indium bump per pixel from three to one just like a monochromatic FPA fabrication; another advantage may be that this QWIP FAP boasts two-color detection capability while only using a monochromatic readout integrated circuit.
Pelican: SCD's 640 × 512/15 μm pitch InSb detector
NASA Astrophysics Data System (ADS)
Oiknine Schlesinger, J.; Calahorra, Z.; Uri, E.; Shick, O.; Fishman, T.; Shtrichman, I.; Sinbar, E.; Nahum, V.; Kahanov, E.; Shlomovich, B.; Hasson, S.; Fishler, N.; Chen, D.; Markovitz, T.
2007-04-01
Over the last decade, SCD has developed and manufactured high quality InSb Focal Plane Arrays (FPAs), that are currently used in different applications worldwide. SCD's production line includes InSb FPAs with mid format (320x256 elements), and large format (640x512 elements), all available in various packaging configurations, including fully integrated Detector-Dewar-Cooler Assemblies (DDCA). Many of SCD's products are fully customized for customers' needs, and are optimized for each application with respect to the weight, power, size, and performance. In 2006, SCD has added to its broad InSb product portfolio the new "Pelican" detector family. All Pelican detectors include a large format 640×512 InSb FPA with 15μm pitch, which is based on the FLIR/Indigo ISC0403 Readout Integrated Circuit (ROIC). Due to its small size, the Pelican FPA fits in any mid format Dewar, enabling upgrading of mid format systems with higher spatial resolution due to its good MTF. This work presents the high performance of Pelican products. As achieved in all SCD's InSb DDC's, the Pelican detectors demonstrate high uniformity and correctability (residual non uniformity less than 0.05% std/DR) and remarkable operability (typically better than 99.9%). The Pelican FPA can be integrated in various DDCA configurations as per application needs, such as light weight, low power and compact form for hand held imagers, or a rigid configuration for environmentally demanding operating and storage conditions.
Kimble, Christopher J; Johnson, David M; Winter, Bruce A; Whitlock, Sidney V; Kressin, Kenneth R; Horne, April E; Robinson, Justin C; Bledsoe, Jonathan M; Tye, Susannah J; Chang, Su-Youne; Agnesi, Filippo; Griessenauer, Christoph J; Covey, Daniel; Shon, Young-Min; Bennet, Kevin E; Garris, Paul A; Lee, Kendall H
2009-01-01
The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans - a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery.
Organic photodetectors and their applications for hemispherical imaging focal plane arrays
NASA Astrophysics Data System (ADS)
Xu, Xin
Softness of organic semiconducting materials holds promise for fabricating optoelectronic devices and circuits on nonplanar surfaces. The low growth temperature of organic small molecules also allows for the deposition onto a plastic substrate, which has the potential for significantly lowering the fabrication cost. However, the softness of organic small molecules can become problematic. Most of the well-established patterning techniques in the semiconductor industry are not suitable for patterning organic-based devices. High temperatures, high pressures, exposure to wet chemicals or high-energy particles that may exist in the conventional patterning approaches can damage the organic active layers. Although methods for large area patterning of organic electronics onto planar substrates have been demonstrated, in this thesis we extend the patterning capability to curved surfaces by using a novel three dimensional (3D) cold welding method. We use 3D cold welding to fabricate a hemispherical focal plane array (FPA) for compact imaging systems that mimic the architecture and function of the human eye. A 10 kilopixel organic photodetector FPA is thus demonstrated on a 1 cm radius hemisphere. By patterning brittle yet transparent indium tin oxide anodes instead of semitransparent metal anodes on the hemispheres, the detectivity of the FPA is improved. We introduce a sensitive hybrid photodetector employing a carbon nanotube/small molecular organic junction with a broad spectral response extending into the near infrared. Since the photodetector array shows an increased noise level with the array size, integrated arrays of organic photodetectors and thin film transistors as switches are demonstrated.
Kimble, Christopher J.; Johnson, David M.; Winter, Bruce A.; Whitlock, Sidney V.; Kressin, Kenneth R.; Horne, April E.; Robinson, Justin C.; Bledsoe, Jonathan M.; Tye, Susannah J.; Chang, Su-Youne; Agnesi, Filippo; Griessenauer, Christoph J.; Covey, Daniel; Shon, Young-Min; Bennet, Kevin E.; Garris, Paul A.; Lee, Kendall H.
2010-01-01
The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth® radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans—a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery. PMID:19963865
Yoon, Roe-Hoan; Adel, Gregory T.; Luttrell, Gerald H.
1995-01-01
An apparatus is disclosed for the microbubble flotation separation of very fine and coarse particles, especially coal, and minerals so as to produce high purity and high recovery efficiency. This is accomplished through the use of a flotation column, microbubbles, recycling of the flotation pulp, and countercurrent wash water to gently wash the froth. Also disclosed are unique processes and apparatus for generating microbubbles for flotation in a highly efficient and inexpensive manner using either a porous tube or in-line static generators.
Yoon, R.H.; Adel, G.T.; Luttrell, G.H.
1995-03-14
An apparatus is disclosed for the microbubble flotation separation of very fine and coarse particles, especially coal, and minerals so as to produce high purity and high recovery efficiency. This is accomplished through the use of a flotation column, microbubbles, recycling of the flotation pulp, and countercurrent wash water to gently wash the froth. Also disclosed are unique processes and apparatus for generating microbubbles for flotation in a highly efficient and inexpensive manner using either a porous tube or in-line static generators. 14 figs.
Processing device with self-scrubbing logic
Wojahn, Christopher K.
2016-03-01
An apparatus includes a processing unit including a configuration memory and self-scrubber logic coupled to read the configuration memory to detect compromised data stored in the configuration memory. The apparatus also includes a watchdog unit external to the processing unit and coupled to the self-scrubber logic to detect a failure in the self-scrubber logic. The watchdog unit is coupled to the processing unit to selectively reset the processing unit in response to detecting the failure in the self-scrubber logic. The apparatus also includes an external memory external to the processing unit and coupled to send configuration data to the configuration memory in response to a data feed signal outputted by the self-scrubber logic.
Fluorine separation and generation device
The Regents of the University of California
2008-12-23
A process and apparatus for the electrolytic separation of fluorine from a mixture of gases is disclosed. Also described is the process and apparatus for the generation of fluorine from fluorine/fluoride containing solids, liquids or gases.
Method and apparatus for combination catalyst for reduction of NO.sub.x in combustion products
Socha, Richard F.; Vartuli, James C.; El-Malki, El-Mekki; Kalyanaraman, Mohan; Park, Paul W.
2010-09-28
A method and apparatus for catalytically processing a gas stream passing therethrough to reduce the presence of NO.sub.x therein, wherein the apparatus includes a first catalyst composed of a silver containing alumina that is adapted for catalytically processing the gas stream at a first temperature range, and a second catalyst composed of a copper containing zeolite located downstream from the first catalyst, wherein the second catalyst is adapted for catalytically processing the gas stream at a lower second temperature range relative to the first temperature range.
Pulse combusted acoustic agglomeration apparatus and process
Mansour, Momtaz N.
1993-01-01
An improved apparatus and process for removal of particulates entrained in a gas stream are provided. The removal process employs a pulse combustor to provide an acoustic pressure wave to acoustically enhance bimodal agglomeration of particulates which may be collected and removed using a conventional separation apparatus. A particulate having a size different from the size of the particulate in the gas stream to be cleaned is introduced into the system to effectuate the bimodal process. The apparatus may be employed as a direct fired system for improved operation of gas-operated equipment such as a gas turbine, or may, alternatively, be employed as an add-on subsystem for combustion exhaust clean-up. Additionally, the added particulate may be a sorbent for effecting sorption of other contaminants such as sulfur. Various other particulates for contaminant removal may also be introduced into the system as exemplified by alkali-gettering agents.
Crewe, Albert V.
2000-01-01
Disclosed are lens apparatus in which a beam of charged particlesis brought to a focus by means of a magnetic field, the lens being situated behind the target position. In illustrative embodiments, a lens apparatus is employed in a scanning electron microscopeas the sole lens for high-resolution focusing of an electron beam, and in particular, an electron beam having an accelerating voltage of from about 10 to about 30,000 V. In one embodiment, the lens apparatus comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. In other embodiments, the lens apparatus comprises a magnetic dipole or virtual magnetic monopole fabricated from a variety of materials, including permanent magnets, superconducting coils, and magnetizable spheres and needles contained within an energy-conducting coil. Multiple-array lens apparatus are also disclosed for simultaneous and/or consecutive imaging of multiple images on single or multiple specimens. The invention further provides apparatus, methods, and devices useful in focusing charged particle beams for lithographic processes.
Gourley, Paul L.; Gourley, Mark F.
1997-01-01
An apparatus and method for microscopic and spectroscopic analysis and processing of biological cells. The apparatus comprises a laser having an analysis region within the laser cavity for containing one or more biological cells to be analyzed. The presence of a cell within the analysis region in superposition with an activated portion of a gain medium of the laser acts to encode information about the cell upon the laser beam, the cell information being recoverable by an analysis means that preferably includes an array photodetector such as a CCD camera and a spectrometer. The apparatus and method may be used to analyze biomedical cells including blood cells and the like, and may include processing means for manipulating, sorting, or eradicating cells after analysis thereof.
Gourley, P.L.; Gourley, M.F.
1997-03-04
An apparatus and method are disclosed for microscopic and spectroscopic analysis and processing of biological cells. The apparatus comprises a laser having an analysis region within the laser cavity for containing one or more biological cells to be analyzed. The presence of a cell within the analysis region in superposition with an activated portion of a gain medium of the laser acts to encode information about the cell upon the laser beam, the cell information being recoverable by an analysis means that preferably includes an array photodetector such as a CCD camera and a spectrometer. The apparatus and method may be used to analyze biomedical cells including blood cells and the like, and may include processing means for manipulating, sorting, or eradicating cells after analysis. 20 figs.
Focal plane arrays based on Type-II indium arsenide/gallium antimonide superlattices
NASA Astrophysics Data System (ADS)
Delaunay, Pierre-Yves
The goal of this work is to demonstrate that Type-II InAs/GaSb superlattices can perform high quality infrared imaging from the middle (MWIR) to the long (LWIR) wavelength infrared range. Theoretically, focal plane arrays (FPAs) based on this technology could be operated at higher temperatures, with lower dark currents than the leading HgCdTe platform. This effort will focus on the fabrication of MWIR and LWIR FPAs with performance similar to existing infrared cameras. Some applications in the MWIR require fast, sensitive imagers able to sustain frame rates up to 100Hz. Such speed can only be achieved with photon detectors. However, these cameras need to be operated below 170K. Current research in this spectral band focuses on increasing the operating temperature of the FPA to a point where cooling could be performed with compact and reliable thermoelectric coolers. Type-II superlattice was used to demonstrate a camera that presented similar performance to HgCdTe and that could be operated up to room temperature. At 80K, the camera could detect temperature differences as low as 10 mK for an integration time shorter than 25 ms. In the LWIR, the electric performance of Type-II photodiodes is mainly limited by surface leakage. Aggressive processing steps such as hybridization and underfill can increase the dark current of the devices by several orders of magnitude. New cleaning and passivation techniques were used to reduce the dark current of FPA diodes by two orders of magnitudes. The absorbing GaSb substrate was also removed to increase the quantum efficiency of the devices up to 90%. At 80K, a FPA with a 9.6 microm 50%-cutoff in responsivity was able to detect temperature differences as low as 19 mK, only limited by the performance of the testing system. The non-uniformity in responsivity reached 3.8% for a 98.2% operability. The third generation of infrared cameras is based on multi-band imaging in order to improve the recognition capabilities of the imager. Preliminary detectors based on back to back diodes presented similar performance to single colors devices; the quantum efficiency was measured higher than 40% for both bands. Preliminary imaging results were demonstrated in the LWIR.
Processing device with self-scrubbing logic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wojahn, Christopher K.
An apparatus includes a processing unit including a configuration memory and self-scrubber logic coupled to read the configuration memory to detect compromised data stored in the configuration memory. The apparatus also includes a watchdog unit external to the processing unit and coupled to the self-scrubber logic to detect a failure in the self-scrubber logic. The watchdog unit is coupled to the processing unit to selectively reset the processing unit in response to detecting the failure in the self-scrubber logic. The apparatus also includes an external memory external to the processing unit and coupled to send configuration data to the configurationmore » memory in response to a data feed signal outputted by the self-scrubber logic.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-04
... (FPA), proposing to study the feasibility of the Microturbine Hydrokinetic River-In-Stream Energy.... Applicant Contact: Mr. Steven M. Selvaggio, Whitestone Power and Communications, P.O. Box 1630, Delta...
Fluid/Gravity Correspondence, Second Order Transport and Gravitational Anomaly***
NASA Astrophysics Data System (ADS)
Megías, Eugenio; Pena-Benitez, Francisco
2014-03-01
We study the transport properties of a relativistic fluid affected by chiral and gauge-gravitational anomalies. The computation is performed in the framework of the fluid/gravity correspondence for a 5 dim holographic model with Chern-Simons terms in the action. We find new anomalous and non anomalous transport coefficients, as well as new contributions to the existing ones coming from the mixed gauge-gravitational anomaly. Consequences for the shear waves dispersion relation are analyzed. Talk given by E. Megías at the International Nuclear Physics Conference INPC 2013, 2-7 June 2013, Firenze, Italy.Supported by Plan Nacional de Altas Energías (FPA2009-07908, FPA2011-25948), Spanish MICINN Consolider-Ingenio 2010 Programme CPAN (CSD2007-00042), Comunidad de Madrid HEP-HACOS S2009/ESP-1473, Spanish MINECO's Centro de Excelencia Severo Ochoa Program (SEV-2012-0234, SEV-2012-0249), and the Juan de la Cierva Program.
Large-Format Dual-Counter Pixelated X-Ray Detector Platform: Phase II Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Adam; Williams, George; Huntington, Andrew
2016-10-10
Within the program, a Voxtel led team demonstrated both prototype (48 x 48, 130-μm pitch, VX-798) and full-format (192 x 192, 100-μm pitch, VX-810) versions of a high-dynamic-range, x-ray photon-counting (HDR-XPC) sensor. Within the program the following tasks were completed: 1) integration and evaluation of the VX-798 prototype camera at the Advanced Photon Source beamline at Argonne National Labs; 2) the design, simulation, and fabrication of the full-format VX-810 ROIC was completed; 3) fabrication of thick, fully depleted silicon photodiodes optimized for x-ray photon collection; 4) hybridization of the VX-810 ROIC to the photodiode array in the creation of themore » optically sensitive FPA (FPA), and 4) development of an evaluation camera to enable electrical and optical characterization of the sensor.« less
Simulation of sampling effects in FPAs
NASA Astrophysics Data System (ADS)
Cook, Thomas H.; Hall, Charles S.; Smith, Frederick G.; Rogne, Timothy J.
1991-09-01
The use of multiplexers and large focal plane arrays in advanced thermal imaging systems has drawn renewed attention to sampling and aliasing issues in imaging applications. As evidenced by discussions in a recent workshop, there is no clear consensus among experts whether aliasing in sensor designs can be readily tolerated, or must be avoided at all cost. Further, there is no straightforward, analytical method that can answer the question, particularly when considering image interpreters as different as humans and autonomous target recognizers (ATR). However, the means exist for investigating sampling and aliasing issues through computer simulation. The U.S. Army Tank-Automotive Command (TACOM) Thermal Image Model (TTIM) provides realistic sensor imagery that can be evaluated by both human observers and TRs. This paper briefly describes the history and current status of TTIM, explains the simulation of FPA sampling effects, presents validation results of the FPA sensor model, and demonstrates the utility of TTIM for investigating sampling effects in imagery.
Hydrocarbonaceous material processing methods and apparatus
Brecher, Lee E [Laramie, WY
2011-07-12
Methods and apparatus are disclosed for possibly producing pipeline-ready heavy oil from substantially non-pumpable oil feeds. The methods and apparatus may be designed to produce such pipeline-ready heavy oils in the production field. Such methods and apparatus may involve thermal soaking of liquid hydrocarbonaceous inputs in thermal environments (2) to generate, though chemical reaction, an increased distillate amount as compared with conventional boiling technologies.
Complete liquefaction methods and apparatus
Turner, Terry D.; Wilding, Bruce M.
2013-10-15
A method and apparatus are described to provide complete gas utilization in the liquefaction operation from a source of gas without return of natural gas to the source thereof from the process and apparatus. The mass flow rate of gas input into the system and apparatus may be substantially equal to the mass flow rate of liquefied product output from the system, such as for storage or use.
Suomi NPP VIIRS Prelaunch and On-orbit Geometric Calibration and Characterization
NASA Technical Reports Server (NTRS)
Wolfe, Robert E.; Lin, Guoqing; Nishihama, Masahiro; Tewari, Krishna P.; Tilton, James C.; Isaacman, Alice R.
2013-01-01
The Visible Infrared Imager Radiometer Suite (VIIRS) sensor was launched 28 October 2011 on the Suomi National Polarorbiting Partnership (SNPP) satellite. VIIRS has 22 spectral bands covering the spectrum between 0.412 m and 12.01 m, including 16 moderate resolution bands (M-bands) with a spatial resolution of 750 m at nadir, 5 imaging resolution bands (I-bands) with a spatial resolution of 375 m at nadir, and 1 day-night band (DNB) with a near-constant 750 m spatial resolution throughout the scan. These bands are located in a visible and near infrared (VisNIR) focal plane assembly (FPA), a short- and mid-wave infrared (SWMWIR) FPA and a long-wave infrared (LWIR) FPA. All bands, except the DNB, are co-registered for proper environmental data records (EDRs) retrievals. Observations from VIIRS instrument provide long-term measurements of biogeophysical variables for climate research and polar satellite data stream for the operational communitys use in weather forecasting and disaster relief and other applications. Well Earth-located (geolocated) instrument data is important to retrieving accurate biogeophysical variables. This paper describes prelaunch pointing and alignment measurements, and the two sets of on-orbit correction of geolocation errors, the first of which corrected error from 1,300 m to within 75 m (20 I-band pixel size), and the second of which fine tuned scan angle dependent errors, bringing VIIRS geolocation products to high maturity in one and a half years of the SNPP VIIRS on-orbit operations. Prelaunch calibration and the on-orbit characterization of sensor spatial impulse responses and band-to-band co-registration (BBR) are also described.
NASA Technical Reports Server (NTRS)
Wang, Zhipeng; Xiong, Xiaoxiong
2017-01-01
The MODIS instruments aboard Terra and Aqua satellites are radiometrically calibrated on-orbit with a set of onboard calibrators (OBC) including a solar diffuser (SD), a blackbody (BB) and a space view (SV) port through which the detectors can view the dark space. As a whisk-broom scanning spectroradiometer, thirty-six MODIS spectral bands are assembled in the along-scan direction on four focal plane assemblies (FPA). These bands capture images of the same target sequentially with the motion of a scan mirror. Then the images are co-registered on board by delaying appropriate band dependent amount of time depending on the band locations on the FPA. While this co-registration mechanism is functioning well for the "far field" remote targets such as Earth view (EV) scenes or the Moon, noticeable band-to-band misregistration in the along-scan direction has been observed for near field targets, in particular the OBCs. In this paper, the misregistration phenomenon is presented and analyzed. It is concluded that the root cause of the misregistration is that the rotating element of the instrument, the scan mirror, is displaced from the focus of the telescope primary mirror. The amount of the misregistration is proportional to the band location on the FPA and is inversely proportional to the distance between the target and the scan mirror. The impact of this misregistration to the calibration of MODIS bands is discussed. In particular, the calculation of the detector gain coefficient m1 of bands 8-16 (412 nm 870 nm) is improved by up to 1.5% for Aqua MODIS.
Vacuum packaging of InGaAs focal plane array with four-stage thermoelectric cooler
NASA Astrophysics Data System (ADS)
Mo, De-feng; Liu, Da-fu; Yang, Li-yi; Xu, Qin-fei; Li, Xue
2013-09-01
The InGaAs focal plane array (FPA) detectors, covering the near-infrared 1~2.4 μm wavelength range, have been developed for application in space-based spectroscopy of the Earth atmosphere. This paper shows an all-metal vacuum package design for area array InGaAs detector of 1024×64 pixels, and its architecture will be given. Four-stage thermoelectric cooler (TEC) is used to cool down the FPA chip. To acquire high heat dissipation for TEC's Joule-heat, tungsten copper (CuW80) and kovar (4J29) is used as motherboard and cavity material respectively which joined by brazing. The heat loss including conduction, convection and radiation is analyzed. Finite element model is established to analyze the temperature uniformity of the chip substrate which is made of aluminum nitride (AlN). The performance of The TEC with and without heat load in vacuum condition is tested. The results show that the heat load has little influence to current-voltage relationship of TEC. The temperature difference (ΔT) increases as the input current increases. A linear relationship exists between heat load and ΔT of the TEC. Theoretical analysis and calculation show that the heat loss of radiation and conduction is about 187 mW and 82 mW respectively. Considering the Joule-heat of readout circuit and the heat loss of radiation and conduction, the FPA for a 220 K operation at room temperature can be achieved. As the thickness of AlN chip substrate is thicker than 1 millimeter, the temperature difference can be less than 0.3 K.
November campaign to increase pill awareness.
1993-01-01
70% of respondents in a survey of women using oral contraceptives (OCs) reported that they have forgotten to take at least 1 OC pill. Insufficient information on taking OCs is responsible for such mistakes. Many women calling the hotline of the UK Family Planning Association (FPA) do not really understand how OCs work so they do not actually realize the risks of forgetting to take pills. The UK's Department of Health, FPA, the Royal Pharmaceutical Association, the Health Education Authority, and health agencies in Scotland, Wales, and Northern Ireland have joined together to reduce this ignorance about the significance of not taking pills among the 3 million women in the UK who use OCs. This OC initiative is part of the Pharmacy Healthcare Scheme. 70% of pharmacists in a recent survey claim that customers ask them about contraception, particularly OCs, at least once a month and as often as once a week. Since pharmacists work in the community and are highly trained health professionals, they are in a good position to distribute advice and information. FPA had developed an information pamphlet and poster for the Pharmacy Healthcare Scheme campaign. It plans on distributing more than 500,000 copies to the 13,000 community pharmacies in the UK in November 1993. A briefing sheet to assist pharmacists with doling out advice and information on OCs will accompany the copies. The Scheme also is targeting hospital pharmacies. This initiative hopes to increase awareness about the danger of missing pills, to respond to common questions about OCs, and to encourage women to seek more information about OCs form the pharmacist.
Ogata, Kenji; Takamura, Norito; Tokunaga, Jin; Ikeda, Tetsuya; Setoguchi, Nao; Tanda, Kazuhiro; Yamasaki, Tetsuo; Nishio, Toyotaka; Kawai, Keiichi
2016-04-01
Flurbiprofen axetil (FPA) is an injection product and a prodrug of a non-steroidal anti-inflammatory drug (NSAID). After injection, it is rapidly hydrolyzed to the active form, flurbiprofen (FP). Since frequent injections of FPA can lead to abnormal physiology, an administration strategy is necessary to ensure there is enhancement of the analgesic efficiency of FP after a single dose and to reduce the total number of doses. FP strongly binds to site II of albumin, and thus the free (unbound) FP concentration is low. This study focused on 6-methoxy-2-naphthylacetic acid (6-MNA), the active metabolite of nabumetone (a prodrug of NSAID). We performed ultrafiltration experiments and pharmacokinetics analysis in rats to investigate whether the inhibitory effect of 6-MNA on FP binding to albumin increased the free FP concentration in vitro and in vivo. Results indicated that 6-MNA inhibited the binding of FP to albumin competitively. When 6-MNA was injected in rats, there was a significant increase in the free FP concentration and the area under concentration-time curve (AUC) calculated from the free FP concentration, while there was a significant decrease in the total (bound + free) FP concentration and the AUC calculated from the total FP concentration. These findings indicate that 6-MNA inhibits the protein binding of FP in vivo. This suggests that the frequency of FPA injections can be reduced when administered with nabumetone, as there is increase in the free FP concentration associated with pharmacological effect.
Large format 15μm pitch XBn detector
NASA Astrophysics Data System (ADS)
Karni, Yoram; Avnon, Eran; Ben Ezra, Michael; Berkowitz, Eyal; Cohen, Omer; Cohen, Yossef; Dobromislin, Roman; Hirsh, Itay; Klin, Olga; Klipstein, Philip; Lukomsky, Inna; Nitzani, Michal; Pivnik, Igor; Rozenberg, Omer; Shtrichman, Itay; Singer, Michael; Sulimani, Shay; Tuito, Avi; Weiss, Eliezer
2014-06-01
Over the past few years, a new type of High Operating Temperature (HOT) photon detector has been developed at SCD, which operates in the blue part of the MWIR atmospheric window (3.4 - 4.2 μm). This window is generally more transparent than the red part of the MWIR window (4.4 - 4.9 μm), and thus is especially useful for mid and long range applications. The detector has an InAsSb active layer and is based on the new "XBn" device concept, which eliminates Generation-Recombination dark current and enables operation at temperatures of 150K or higher, while maintaining excellent image quality. Such high operating temperatures reduce the cooling requirements of Focal Plane Array (FPA) detectors dramatically, and allow the use of a smaller closed-cycle Stirling cooler. As a result, the complete Integrated Detector Cooler Assembly (IDCA) has about 60% lower power consumption and a much longer lifetime compared with IDCAs based on standard InSb detectors and coolers operating at 77K. In this work we present a new large format IDCA designed for 150K operation. The 15 μm pitch 1280×1024 FPA is based on SCD's XBn technology and digital Hercules ROIC. The FPA is housed in a robust Dewar and is integrated with Ricor's K508N Stirling cryo-cooler. The IDCA has a weight of ~750 gram and its power consumption is ~ 5.5 W at a frame rate of 100Hz. The Mean Time to Failure (MTTF) of the IDCA is more than 20,000 hours, greatly facilitating 24/7 operation.
Rab, Anna; Dallinger, Susanne; Polak, Kaija; Pleiner, Johannes; Polska, Elzbieta; Wolzt, Michael; Schmetterer, Leopold
2004-05-01
There is evidence that hyperinsulinemia may stimulate endothelin-1 (ET-1) generation or release, which may affect diabetic vascular complications. BQ-123, a specific ET(A) receptor antagonist, was used to investigate if insulin-induced vascular effects are influenced by an acute ET-1 release. Two randomized, placebo-controlled, double-blind, cross-over studies were performed. In protocol 1, 12 healthy subjects received, on separate study days, infusions of BQ-123 (60 microg/min for 30 min) during placebo clamp conditions, BQ-123 during euglycemic hyperinsulinemia (3 mU/kg/min for 390 min), or placebo during euglycemic hyperinsulinemia. Fundus pulsation amplitude (FPA) was measured to assess pulsatile choroidal blood flow, and mean flow velocity (MFV) of the ophtalmic artery was measured by color Doppler imaging. In protocol 2, eight healthy subjects received, on separate study days, intra-arterial infusions of BQ-123 (32 microg/min for 120 min) during placebo or insulin clamp. Forearm blood flow was measured with bilateral plethysmography, expressing the ratio of responses in the intervention arm and in the control arm. Insulin alone increased FPA (+10%, p < 0.001) and forearm blood flow (+19%). BQ-123 increased FPA, MFV, and forearm blood flow ratio in the absence and presence of exogenous insulin, but this effect was not different between normo- and hyperinsulinemic conditions. ET-1 plasma concentrations were not affected by insulin. In conclusion, these data do not support the concept that hyperinsulinemia increases ET-1 generation in healthy subjects. Our results, however, cannot necessarily be extrapolated to diabetic and obese subjects.
Polska, Elzbieta; Luksch, Alexandra; Ehrlich, Paulina; Sieder, Anna; Schmetterer, Leopold
2002-04-01
Two laser based methods for the assessment of ocular hemodynamics in humans have been investigated: laser Doppler flowmetry (LDF) and laser interferometric measurement of fundus pulsation amplitude (FPA). When the laser with either of the two methods is focused onto the fovea it is obvious that only choroidal blood flow contributes to the signals. When the laser is, however, directed to other parts of the retina the situation is more complex. Whereas the retina shows a pronounced vasoconstrictor response to systemic hyperoxia the effect in the choroid is small. We therefore investigated the effect of 100% O2 breathing on results as obtained with the above mentioned techniques at different fundus locations. Twelve healthy subjects were included. Four 15-minutes 100% O2 breathing periods were scheduled for each subject. During two of these breathing periods LDF was performed at the fovea (ChBFf) and at a fundus location approximately 7.5 degrees nasally to the fovea (ChBFp), respectively. During the other two periods FPA was assessed at the same fundus locations (FPAf, FPAp). ChBFf tended to decrease during 100% oxygen breathing (6 +/- 4%), but this effect was not significant. The decrease in ChBFp (10 +/- 4%), was comparable. FPAf (10 +/- 2%; P < 0.001) and FPAp (13 +/- 2%; P < 0.001) decreased significantly during systemic hyperoxia, but again there was no difference in the response obtained at the two fundus locations. When LDF and FPA are applied at the peripheral retina the obtained signal is mainly influenced by the choroidal circulation.
Cheng, Xiaofei; Zhang, Kai; Sun, Xiaojiang; Zhao, Changqing; Li, Hua; Zhao, Jie
2017-07-01
The objective was to analyze the compensatory effect of the pelvis and lower extremities on sagittal spinal malalignment in patients with pelvic incidence (PI) and lumbar lordosis (LL) mismatch. A series of parameters including PI, LL, PI-LL, thoracic kyphosis (TK), pelvic tilt (PT), sacral slope (SS), knee flexion angle (KFA), tibial obliquity angle (TOA), femoral obliquity angle (FOA), femur pelvis angle (FPA) and pelvic shift (PS) were measured. Patients with PI-LL mismatch were divided into pelvic retroversion group and pelvic retroposition group based on their PT and PS, and then the parameters were compared within the two groups and with the control group. All variables were significantly different when comparing the pelvic retroversion and retroposition group with the control group except for PI, FOA and PS in the pelvic retroversion group. The pelvic retroposition group had significantly greater value of PI-LL, PI, PT, KFA, FOA and PS and contribution ratio of FOA and PS, and smaller value of LL, TK and FPA and contribution ratio of PT, TOA and FPA compared with the pelvic retroversion group. Patients with lesser PI-LL mismatch rely more on hip extension to increase pelvic retroversion while those with greater PI-LL mismatch tend to add extra femoral obliquity. When compensating for larger PI-LL mismatch, the importance of hip extension is decreased and the effect of the knee and ankle joint becomes more important by providing greater femoral incline and relatively lesser ankle dorsiflexion respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Apparatus for testing for infection by a retrovirus
Layne, Scott P.; Beugelsdijk, Tony J.
1999-01-01
An apparatus for testing specimens for infection by a retrovirus is described. The apparatus comprises a process controller including a communications module for translating user commands into test instrument suite commands and a means for communicating specimen test results to a user. The apparatus further comprises a test instrument suite including a means for treating the specimen to manifest an observable result and a detector for measuring the observable result.
In-line manufacture of carbon nanotubes
Brambilla, Nicol Michele; Signorelli, Riccardo; Martini, Fabrizio; Corripio Luna, Oscar Enrique
2015-04-28
Mass production of carbon nanotubes (CNT) are facilitated by methods and apparatus disclosed herein. Advantageously, the methods and apparatus make use of a single production unit, and therefore provide for uninterrupted progress in a fabrication process. Embodiments of control systems for a variety of CNT production apparatus are included.
In situ longitudinal pre-stretch in the human femoropopliteal artery.
Kamenskiy, Alexey; Seas, Andreas; Bowen, Grant; Deegan, Paul; Desyatova, Anastasia; Bohlim, Nick; Poulson, William; MacTaggart, Jason
2016-03-01
In situ longitudinal (axial) pre-stretch (LPS) plays a fundamental role in the mechanics of the femoropopliteal artery (FPA). It conserves energy during pulsation and prevents buckling of the artery during limb movement. We investigated how LPS is affected by demographics and risk factors, and how these patient characteristics associate with the structural and physiologic features of the FPA. LPS was measured in n=148 fresh human FPAs (14-80 years old). Mechanical properties were characterized with biaxial extension and histopathological characteristics were quantified with Verhoeff-Van Gieson Staining. Constitutive modeling was used to calculate physiological stresses and stretches which were then analyzed in the context of demographics, risk factors and structural characteristics. Age had the strongest negative effect (r=-0.812, p<0.01) on LPS and could alone explain 66% of LPS variability. Male gender, higher body mass index, hypertension, diabetes, coronary artery disease, dyslipidemia and tobacco use had negative effects on LPS, but only the effect of tobacco was not associated with aging. FPAs with less pre-stretch had thicker medial layers, but thinner intramural elastic fibers with less dense and more fragmented external elastic laminae. Elastin degradation was associated with decreased physiological tethering force and longitudinal stress, while circumferential stress remained constant. FPA wall pathology was negatively associated with LPS (r=-0.553, p<0.01), but the effect was due primarily to aging. LPS in the FPA may serve as an energy reserve for adaptive remodeling. Reduction of LPS due to degradation and fragmentation of intramural longitudinal elastin during aging can be accelerated in tobacco users. This work studies in situ longitudinal pre-stretch (LPS) in the human femoropopliteal artery. LPS has a fundamental role in arterial mechanics, but is rather poorly studied due to lack of direct in vivo measurement method. We have investigated LPS in the n=148 human femoropopliteal arteries in the context of subject demographics and risk factors, and structural and physiologic characteristics of the artery. Our results demonstrate that LPS reduces with age due to degradation and fragmentation of intramural elastin. LPS may serve as an energy reserve for adaptive remodeling, and reduction of LPS can be accelerated in tobacco users. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Chapinal, Núria; Elkin, Brett T; Joly, Damien O; Schumaker, Brant A; Stephen, Craig
2012-08-01
The objective of this study was to estimate agreement between the caudal fold test (CFT) and different serological tests for the detection of Mycobacterium bovis infection in bison by using prevalence-adjusted bias-adjusted kappa (PABAK). A total of 212 of wild wood bison from Wood Buffalo National Park were tested with the CFT as well as several serological tests: fluorescent polarization assay (FPA), multiantigen print immunoassay (MAPIA), rapid lateral-flow test (RT) and dual path platform test (DPP). For RT, 3 variations were conducted using 30μl of serum (RT 30), 20μl of serum (RT 20) and 20μl of serum considering only a strong reaction as positive (RT 20 ST). The McNemar's χ(2) test was conducted to assess whether the proportion of positive test results to 2 different tests differed. Two measures of agreement between pair of tests were estimated: the Cohen's kappa statistic and PABAK. The apparent prevalence of tuberculosis in the sampled animals varied depending on the diagnostic test from 6.1% (FPA and DPP) to 47.2% (CFT). The prevalence estimated by CFT differed from the prevalence estimated by the other tests, whereas the prevalence estimated by FPA, MAPIA, RT 20 ST and DPP were not significantly different. The kappa and PABAK estimates calculated between CFT and the rest of the tests suggested poor to slight agreement between tests (k and PABAK<0.25 in all cases). The PABAK estimates for the pairwise combinations among serological tests were numerically greater than the kappa estimates (and significantly greater when FPA was compared to the rest of serological tests), and suggested substantial to almost perfect agreement (PABAK>0.75 in all cases). The disagreement between the skin and serological tests for the detection of M. bovis infection could be partly because the tests measure different immunological responses (cell-mediated vs. humoral) that are predominant at different stages of the infection, and partly due to inaccuracy of the tests. Further research is needed to evaluate the accuracy of diagnostic tests in order to establish a reliable case definition, combining different tests, to be used in the surveillance and control of tuberculosis in free-ranging bison populations. Copyright © 2012 Elsevier B.V. All rights reserved.
Separation process using microchannel technology
Tonkovich, Anna Lee [Dublin, OH; Perry, Steven T [Galloway, OH; Arora, Ravi [Dublin, OH; Qiu, Dongming [Bothell, WA; Lamont, Michael Jay [Hilliard, OH; Burwell, Deanna [Cleveland Heights, OH; Dritz, Terence Andrew [Worthington, OH; McDaniel, Jeffrey S [Columbus, OH; Rogers, Jr; William, A [Marysville, OH; Silva, Laura J [Dublin, OH; Weidert, Daniel J [Lewis Center, OH; Simmons, Wayne W [Dublin, OH; Chadwell, G Bradley [Reynoldsburg, OH
2009-03-24
The disclosed invention relates to a process and apparatus for separating a first fluid from a fluid mixture comprising the first fluid. The process comprises: (A) flowing the fluid mixture into a microchannel separator in contact with a sorption medium, the fluid mixture being maintained in the microchannel separator until at least part of the first fluid is sorbed by the sorption medium, removing non-sorbed parts of the fluid mixture from the microchannel separator; and (B) desorbing first fluid from the sorption medium and removing desorbed first fluid from the microchannel separator. The process and apparatus are suitable for separating nitrogen or methane from a fluid mixture comprising nitrogen and methane. The process and apparatus may be used for rejecting nitrogen in the upgrading of sub-quality methane.
Method and system for diagnostics of apparatus
NASA Technical Reports Server (NTRS)
Gorinevsky, Dimitry (Inventor)
2012-01-01
Proposed is a method, implemented in software, for estimating fault state of an apparatus outfitted with sensors. At each execution period the method processes sensor data from the apparatus to obtain a set of parity parameters, which are further used for estimating fault state. The estimation method formulates a convex optimization problem for each fault hypothesis and employs a convex solver to compute fault parameter estimates and fault likelihoods for each fault hypothesis. The highest likelihoods and corresponding parameter estimates are transmitted to a display device or an automated decision and control system. The obtained accurate estimate of fault state can be used to improve safety, performance, or maintenance processes for the apparatus.
A mathematical analysis of drug dissolution in the USP flow through apparatus
NASA Astrophysics Data System (ADS)
McDonnell, David; D'Arcy, D. M.; Crane, L. J.; Redmond, Brendan
2018-03-01
This paper applies boundary layer theory to the process of drug dissolution in the USP (United States Pharmacopeia) Flow Through Apparatus. The mass transfer rate from the vertical planar surface of a compact within the device is examined. The theoretical results obtained are then compared with those of experiment. The paper also examines the effect on the dissolution process caused by the interaction between natural and forced convection within the apparatus and the introduction of additional boundaries.
Apparatus for controlling fluidized beds
Rehmat, Amirali G.; Patel, Jitendra G.
1987-05-12
An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.
75 FR 80800 - Notice of Availability of Government-Owned Inventions; Available for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
... made available for licensing by the Department of the Navy. Navy Case No. 83951--Apparatus and System... No. 98721--Static Wireless Data-Glove Apparatus for Gesture Processing and Recognition and... Avoidance Decisions; Navy Case No. 98745--Method of Fabricating A Micro-Electro-Mechanical Apparatus for...
Lyons, K. David; James, Robert; Berry, David A.; Gardner, Todd
2004-09-21
The invention provides a method and apparatus for producing a synthesis gas from a variety of hydrocarbons. The apparatus (device) consists of a semi-batch, non-constant volume reactor to generate a synthesis gas. While the apparatus feeds mixtures of air, steam, and hydrocarbons into a cylinder where work is performed on the fluid by a piston to adiabatically raise its temperature without heat transfer from an external source.
Apparatus and process for separating hydrogen isotopes
Heung, Leung K; Sessions, Henry T; Xiao, Xin
2013-06-25
The apparatus and process for separating hydrogen isotopes is provided using dual columns, each column having an opposite hydrogen isotopic effect such that when a hydrogen isotope mixture feedstock is cycled between the two respective columns, two different hydrogen isotopes are separated from the feedstock.
Absolute stellar photometry on moderate-resolution FPA images
Stone, T.C.
2009-01-01
An extensive database of star (and Moon) images has been collected by the ground-based RObotic Lunar Observatory (ROLO) as part of the US Geological Survey program for lunar calibration. The stellar data are used to derive nightly atmospheric corrections for the observations from extinction measurements, and absolute calibration of the ROLO sensors is based on observations of Vega and published reference flux and spectrum data. The ROLO telescopes were designed for imaging the Moon at moderate resolution, thus imposing some limitations for the stellar photometry. Attaining accurate stellar photometry with the ROLO image data has required development of specialized processing techniques. A key consideration is consistency in discriminating the star core signal from the off-axis point spread function. The analysis and processing methods applied to the ROLO stellar image database are described. ?? 2009 BIPM and IOP Publishing Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... suspension and refund authority under section 205(e) of the FPA, to protect customers of electricity from... section 206 has eliminated some of the differences underlying the finding in Southwestern, a fundamental...
Bulicz, Tytus R.
1990-01-01
An apparatus and process for fluidizing solid particles by causing rotary motion of the solid particles in a fluidizing chamber by a plurality of rotating projections extending from a rotatable cylinder end wall interacting with a plurality of fixed projections extending from an opposite fixed end wall and passing the solid particles through a radial feed orifice open to the solids fluidizing chamber on one side and a solid particle utilization device on the other side. The apparatus and process are particularly suited for obtaining intermittent feeding with continual solids supply to the fluidizing chamber. The apparatus and process are suitable for injecting solid particles, such as coal, to an internal combustion engine.
78 FR 4138 - Notice of Intent To Grant Co-Exclusive Licenses
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... brine solution.//Patent Application Serial No. 13/426294: Process and apparatus for the selective dimerization of terpenes and alpha-olefin oligomers with a single-stage reactor and a single-stage fractionation system.//Patent Application Serial No. 13/426347: Process and apparatus for the selective...
Apparatus and method for stabilization or oxidation of polymeric materials
Paulauskas, Felix L [Knoxville, TN; Sherman, Daniel M [Knoxville, TN
2010-01-19
An apparatus for treating polymeric materials comprises a treatment chamber adapted to maintain a selected atmosphere at a selected temperature; a means for supporting the polymeric material within the chamber; and, a source of ozone-containing gas, which decomposes at the selected temperature yielding at least one reactive oxidative species whereby the polymer is stabilized and cross linked through exposure to the oxidative species in the chamber at the selected temperature. The ozone may be generated by a plasma discharge or by various chemical processes. The apparatus may be configured for either batch-type or continuous-type processing. The apparatus and method are especially useful for preparing polymer fibers, particularly PAN fibers, for later carbonization treatments as well as to make flame-retardant fabrics.
Infrared image enhancement based on the edge detection and mathematical morphology
NASA Astrophysics Data System (ADS)
Zhang, Linlin; Zhao, Yuejin; Dong, Liquan; Liu, Xiaohua; Yu, Xiaomei; Hui, Mei; Chu, Xuhong; Gong, Cheng
2010-11-01
The development of the un-cooled infrared imaging technology from military necessity. At present, It is widely applied in industrial, medicine, scientific and technological research and so on. The infrared radiation temperature distribution of the measured object's surface can be observed visually. The collection of infrared images from our laboratory has following characteristics: Strong spatial correlation, Low contrast , Poor visual effect; Without color or shadows because of gray image , and has low resolution; Low definition compare to the visible light image; Many kinds of noise are brought by the random disturbances of the external environment. Digital image processing are widely applied in many areas, it can now be studied up close and in detail in many research field. It has become one kind of important means of the human visual continuation. Traditional methods for image enhancement cannot capture the geometric information of images and tend to amplify noise. In order to remove noise and improve visual effect. Meanwhile, To overcome the above enhancement issues. The mathematical model of FPA unit was constructed based on matrix transformation theory. According to characteristics of FPA, Image enhancement algorithm which combined with mathematical morphology and edge detection are established. First of all, Image profile is obtained by using the edge detection combine with mathematical morphological operators. And then, through filling the template profile by original image to get the ideal background image, The image noise can be removed on the base of the above method. The experiments show that utilizing the proposed algorithm can enhance image detail and the signal to noise ratio.
Mao, Samuel S; Grigoropoulos, Costas P; Hwang, David J; Minor, Andrew M
2013-11-12
Laser-assisted apparatus and methods for performing nanoscale material processing, including nanodeposition of materials, can be controlled very precisely to yield both simple and complex structures with sizes less than 100 nm. Optical or thermal energy in the near field of a photon (laser) pulse is used to fabricate submicron and nanometer structures on a substrate. A wide variety of laser material processing techniques can be adapted for use including, subtractive (e.g., ablation, machining or chemical etching), additive (e.g., chemical vapor deposition, selective self-assembly), and modification (e.g., phase transformation, doping) processes. Additionally, the apparatus can be integrated into imaging instruments, such as SEM and TEM, to allow for real-time imaging of the material processing.
Film/Adhesive Processing Module for Fiber-Placement Processing of Composites
NASA Technical Reports Server (NTRS)
Hulcher, A. Bruce
2007-01-01
An automated apparatus has been designed and constructed that enables the automated lay-up of composite structures incorporating films, foils, and adhesives during the automated fiber-placement process. This apparatus, denoted a film module, could be used to deposit materials in film or thin sheet form either simultaneously when laying down the fiber composite article or in an independent step.
50 CFR 221.2 - What terms are used in this part?
Code of Federal Regulations, 2014 CFR
2014-10-01
... Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Intervention means a... hydroelectric facility under 18 CFR parts 4 or 5. Material fact means a fact that, if proved, may affect a...
50 CFR 221.2 - What terms are used in this part?
Code of Federal Regulations, 2013 CFR
2013-10-01
... Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Intervention means a... hydroelectric facility under 18 CFR parts 4 or 5. Material fact means a fact that, if proved, may affect a...
Code of Federal Regulations, 2010 CFR
2010-04-01
..., including, but not limited to, those that both before and after the transaction remain under the functional...) Transactions that do not require an Appendix A analysis; 1 and 1 Inquiry Concerning the Commission's Merger...
Lindenmeyer, C.W.
1993-01-26
An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.
Apparatus for controlling fluidized beds
Rehmat, A.G.; Patel, J.G.
1987-05-12
An apparatus and process are disclosed for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance. 2 figs.
McGrail, Bernard P.; Martin, Paul F.; Lindenmeier, Clark W.
1999-01-01
The present invention is a method and apparatus for measuring coupled flow, transport and reaction processes under liquid unsaturated flow conditions. The method and apparatus of the present invention permit distinguishing individual precipitation events and their effect on dissolution behavior isolated to the specific event. The present invention is especially useful for dynamically measuring hydraulic parameters when a chemical reaction occurs between a particulate material and either liquid or gas (e.g. air) or both, causing precipitation that changes the pore structure of the test material.
Lindenmeyer, Carl W.
1993-01-01
An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.
Davalos, Rafael V [Oakland, CA; Ellis, Christopher R. B. [Oakland, CA
2008-03-04
Disclosed is an apparatus and method for inserting one or several chemical or biological species into phospholipid containers that are controlled within a microfluidic network, wherein individual containers are tracked and manipulated by electric fields and wherein the contained species may be chemically processed.
NASA Astrophysics Data System (ADS)
Ruffini, R.; Wang, Y.; Aimuratov, Y.; Barres de Almeida, U.; Becerra, L.; Bianco, C. L.; Chen, Y. C.; Karlica, M.; Kovacevic, M.; Li, L.; Melon Fuksman, J. D.; Moradi, R.; Muccino, M.; Penacchioni, A. V.; Pisani, G. B.; Primorac, D.; Rueda, J. A.; Shakeri, S.; Vereshchagin, G. V.; Xue, S.-S.
2018-01-01
We analyze the early X-ray flares in the GRB “flare–plateau–afterglow” (FPA) phase observed by Swift-XRT. The FPA occurs only in one of the seven GRB subclasses: the binary-driven hypernovae (BdHNe). This subclass consists of long GRBs with a carbon–oxygen core and a neutron star (NS) binary companion as progenitors. The hypercritical accretion of the supernova (SN) ejecta onto the NS can lead to the gravitational collapse of the NS into a black hole. Consequently, one can observe a GRB emission with isotropic energy {E}{iso}≳ {10}52 erg, as well as the associated GeV emission and the FPA phase. Previous work had shown that gamma-ray spikes in the prompt emission occur at ∼ {10}15{--}{10}17 cm with Lorentz Gamma factors {{Γ }}∼ {10}2{--}{10}3. Using a novel data analysis, we show that the time of occurrence, duration, luminosity, and total energy of the X-ray flares correlate with E iso. A crucial feature is the observation of thermal emission in the X-ray flares that we show occurs at radii ∼1012 cm with {{Γ }}≲ 4. These model-independent observations cannot be explained by the “fireball” model, which postulates synchrotron and inverse-Compton radiation from a single ultrarelativistic jetted emission extending from the prompt to the late afterglow and GeV emission phases. We show that in BdHNe a collision between the GRB and the SN ejecta occurs at ≃1010 cm, reaching transparency at ∼1012 cm with {{Γ }}≲ 4. The agreement between the thermal emission observations and these theoretically derived values validates our model and opens the possibility of testing each BdHN episode with the corresponding Lorentz Gamma factor.
Hess, Katharina; Ajjan, Ramzi; Phoenix, Fladia; Dobó, József; Gál, Péter; Schroeder, Verena
2012-01-01
Background Numerous interactions between the coagulation and complement systems have been shown. Recently, links between coagulation and mannan-binding lectin-associated serine protease-1 (MASP-1) of the complement lectin pathway have been proposed. Our aim was to investigate MASP-1 activation of factor XIII (FXIII), fibrinogen, prothrombin, and thrombin-activatable fibrinolysis inhibitor (TAFI) in plasma-based systems, and to analyse effects of MASP-1 on plasma clot formation, structure and lysis. Methodology/Principal Findings We used a FXIII incorporation assay and specific assays to measure the activation products prothrombin fragment F1+2, fibrinopeptide A (FPA), and activated TAFI (TAFIa). Clot formation and lysis were assessed by turbidimetric assay. Clot structure was studied by scanning electron microscopy. MASP-1 activated FXIII and, contrary to thrombin, induced FXIII activity faster in the Val34 than the Leu34 variant. MASP-1-dependent generation of F1+2, FPA and TAFIa showed a dose-dependent response in normal citrated plasma (NCP), albeit MASP-1 was much less efficient than FXa or thrombin. MASP-1 activation of prothrombin and TAFI cleavage were confirmed in purified systems. No FPA generation was observed in prothrombin-depleted plasma. MASP-1 induced clot formation in NCP, affected clot structure, and prolonged clot lysis. Conclusions/Significance We show that MASP-1 interacts with plasma clot formation on different levels and influences fibrin structure. Although MASP-1-induced fibrin formation is thrombin-dependent, MASP-1 directly activates prothrombin, FXIII and TAFI. We suggest that MASP-1, in concerted action with other complement and coagulation proteins, may play a role in fibrin clot formation. PMID:22536427
Cherry-Slush-Candling Apparatus
NASA Technical Reports Server (NTRS)
Stephens, James B.; Weiss, James R.; Hoover, Gordon
1996-01-01
Proposed infrared-scanning apparatus for use in bakeries making cherry pies detect cherry pits remaining in cherry slush after pitting process. Pits detected via their relative opacity to infrared radiation.
Apparatus for automated testing of biological specimens
Layne, Scott P.; Beugelsdijk, Tony J.
1999-01-01
An apparatus for performing automated testing of infections biological specimens is disclosed. The apparatus comprise a process controller for translating user commands into test instrument suite commands, and a test instrument suite comprising a means to treat the specimen to manifest an observable result, and a detector for measuring the observable result to generate specimen test results.
Apparatus for converting biomass to a pumpable slurry
Ergun, Sabri; Schaleger, Larry L.; Wrathall, James A.; Yaghoubzadeh, Nasser
1986-01-01
An apparatus used in the pretreatment of wood chips in a process for converting biomass to a liquid hydrocarbonaceous fuel. The apparatus functions to break down the wood chips to a size distribution that can be readily handled in a slurry form. Low maintenance operation is obtained by hydrolyzing the chips in a pressure vessel having no moving parts.
Bulicz, T.R.
1990-04-17
An apparatus and process are described for fluidizing solid particles by causing rotary motion of the solid particles in a fluidizing chamber by a plurality of rotating projections extending from a rotatable cylinder end wall interacting with a plurality of fixed projections extending from an opposite fixed end wall and passing the solid particles through a radial feed orifice open to the solids fluidizing chamber on one side and a solid particle utilization device on the other side. The apparatus and process are particularly suited for obtaining intermittent feeding with continual solids supply to the fluidizing chamber. The apparatus and process are suitable for injecting solid particles, such as coal, to an internal combustion engine. 3 figs.
78 FR 60271 - Project No. 13599-001
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Project No. 13599-001] Green Power... (FPA), proposing to study the feasibility of the Lake 3160 Hydroelectric Project (project) to be.... The project would occupy about 475 acres of lands within the Tongass National Forest managed by the U...
NASA Astrophysics Data System (ADS)
Herraiz, M.; de Vicente, G.; Lindo-Ñaupari, R.; Giner, J.; Simón, J. L.; GonzáLez-Casado, J. M.; Vadillo, O.; RodríGuez-Pascua, M. A.; CicuéNdez, J. I.; Casas, A.; CabañAs, L.; Rincón, P.; CortéS, A. L.; RamíRez, M.; Lucini, M.
2000-08-01
A general synthesis of the recent and present stress situation and evolution in the Iberian Peninsula was obtained from microstructural and seismological analysis. The stress evolution was deduced from (1) fault population analysis (FPA) from 409 sites distributed throughout the Iberian Peninsula, (2) paleostress indicators given by 324 stations taken from the bibliography, and (3) seismic data corresponding to 161 focal mechanisms evenly spread in the studied region. The application of FPA together with the determination of stress tensors and focal mechanisms for the whole Iberian microplate has provided two main results: (1) the Iberian Peninsula is undergoing a NW-SE oriented compression, except for the northeastern part (Pyrenees, Ebro Basin, and Iberian Chain), where it is N-S to NE-SW, and the Gulf of Cádiz, where it seems to be E-W, and (2) the main trends of the stress field have remained almost constant since the upper Miocene. The analysis performed by zones suggests the presence of local heterogeneities in the stress field.
NASA Astrophysics Data System (ADS)
Xu, Zhipeng; Wei, Jun; Li, Jianwei; Zhou, Qianting
2010-11-01
An image spectrometer of a spatial remote sensing satellite requires shortwave band range from 2.1μm to 3μm which is one of the most important bands in remote sensing. We designed an infrared sub-system of the image spectrometer using a homemade 640x1 InGaAs shortwave infrared sensor working on FPA system which requires high uniformity and low level of dark current. The working temperature should be -15+/-0.2 Degree Celsius. This paper studies the model of noise for focal plane array (FPA) system, investigated the relationship with temperature and dark current noise, and adopts Incremental PID algorithm to generate PWM wave in order to control the temperature of the sensor. There are four modules compose of the FPGA module design. All of the modules are coded by VHDL and implemented in FPGA device APA300. Experiment shows the intelligent temperature control system succeeds in controlling the temperature of the sensor.
A Low Cost Approach to the Design of Autopilot for Hypersonic Glider
NASA Astrophysics Data System (ADS)
Liang, Wang; Weihua, Zhang; Ke, Peng; Donghui, Wang
2017-12-01
This paper proposes a novel integrated guidance and control (IGC) approach to improve the autopilot design with low cost for hypersonic glider in dive and pull-up phase. The main objective is robust and adaptive tracking of flight path angle (FPA) under severe flight scenarios. Firstly, the nonlinear IGC model is developed with a second order actuator dynamics. Then the adaptive command filtered back-stepping control is implemented to deal with the large aerodynamics coefficient uncertainties, control surface uncertainties and unmatched time-varying disturbances. For the autopilot, a back-stepping sliding mode control is designed to track the control surface deflection, and a nonlinear differentiator is used to avoid direct differentiating the control input. Through a series of 6-DOF numerical simulations, it’s shown that the proposed scheme successfully cancels out the large uncertainties and disturbances in tracking different kinds of FPA trajectory. The contribution of this paper lies in the application and determination of nonlinear integrated design of guidance and control system for hypersonic glider.
Soehnel, Grant; Tanbakuchi, Anthony
2012-11-20
A custom IR spot scanning experiment was constructed to project subpixel spots on a mercury cadmium telluride focal plane array (FPA). The hardware consists of an FPA in a liquid nitrogen cooled Dewar, high precision motorized stages, a custom aspheric lens, and a 1.55 and 3.39 μm laser source. By controlling the position and intensity of the spot, characterizations of cross talk, saturation, blooming, and (indirectly) the minority carrier lifetime were performed. In addition, a Monte-Carlo-based charge diffusion model was developed to validate experimental data and make predictions. Results show very good agreement between the model and experimental data. Parameters such as wavelength, reverse bias, and operating temperature were found to have little effect on pixel crosstalk in the absorber layer of the detector. Saturation characterizations show that these FPAs, which do not have antiblooming circuitry, exhibit an increase in cross talk due to blooming at ∼39% beyond the flux required for analog saturation.
Evaluating Flight Crew Operator Manual Documentation
NASA Technical Reports Server (NTRS)
Sherry, Lance; Feary, Michael
1998-01-01
Aviation and cognitive science researchers have identified situations in which the pilot s expectations for the behavior of the avionics are not matched by the actual behavior of the avionics. Researchers have attributed these "automation surprises" to the complexity of the avionics mode logic, the absence of complete training, limitations in cockpit displays, and ad-hoc conceptual models of the avionics. Complete canonical rule-based descriptions of the behavior of the autopilot provide the basis for understanding the perceived complexity of the autopilots, the differences between the pilot s and autopilot s conceptual models, and the limitations in training materials and cockpit displays. This paper compares the behavior of the autopilot Vertical Speed/Flight Path Angle (VS-FPA) mode as described in the Flight Crew Operators Manual (FCOM) and the actual behavior of the VS-FPA mode defined in the autopilot software. This example demonstrates the use of the Operational Procedure Model (OPM) as a method for using the requirements specification for the design of the software logic as information requirements for training.
Further applications for mosaic pixel FPA technology
NASA Astrophysics Data System (ADS)
Liddiard, Kevin C.
2011-06-01
In previous papers to this SPIE forum the development of novel technology for next generation PIR security sensors has been described. This technology combines the mosaic pixel FPA concept with low cost optics and purpose-designed readout electronics to provide a higher performance and affordable alternative to current PIR sensor technology, including an imaging capability. Progressive development has resulted in increased performance and transition from conventional microbolometer fabrication to manufacture on 8 or 12 inch CMOS/MEMS fabrication lines. A number of spin-off applications have been identified. In this paper two specific applications are highlighted: high performance imaging IRFPA design and forest fire detection. The former involves optional design for small pixel high performance imaging. The latter involves cheap expendable sensors which can detect approaching fire fronts and send alarms with positional data via mobile phone or satellite link. We also introduce to this SPIE forum the application of microbolometer IR sensor technology to IoT, the Internet of Things.
Apparatus with moderating material for microwave heat treatment of manufactured components
Ripley, Edward B [Knoxville, TN
2011-05-10
An apparatus for heat treating manufactured components using microwave energy and microwave susceptor material. Heat treating medium such as eutectic salts may be employed. A fluidized bed introduces process gases which may include carburizing or nitriding gases The process may be operated in a batch mode or continuous process mode. A microwave heating probe may be used to restart a frozen eutectic salt bath.
Apparatus for microwave heat treatment of manufactured components
Babcock & Wilcox Technical Services Y-12, LLC
2008-04-15
An apparatus for heat treating manufactured components using microwave energy and microwave susceptor material. Heat treating medium such as eutectic salts may be employed. A fluidized bed introduces process gases which may include carburizing or nitriding gases. The process may be operated in a batch mode or continuous process mode. A microwave heating probe may be used to restart a frozen eutectic salt bath.
Orbital fabrication of aluminum foam and apparatus therefore
NASA Technical Reports Server (NTRS)
Tucker, Dennis S. (Inventor)
2010-01-01
A process for producing foamed aluminum in space comprising the steps of: heating aluminum until it is molten; applying the force of gravity to the molten aluminum; injecting gas into the molten aluminum to produce molten foamed aluminum; and allowing the molten foamed aluminum to cool to below melting temperature. The apparatus for carrying out this invention comprises: a furnace which rotates to simulate the force of gravity and heats the aluminum until it is molten; a door on the furnace, which is opened for charging the aluminum into the furnace, closed for processing and opened again for removal of the foamed aluminum; a gas injection apparatus for injecting gas into the molten aluminum within the furnace; and an extraction apparatus adjacent the door for removing the foamed aluminum from the furnace.
Hybrid Contactless Heating and Levitation
NASA Technical Reports Server (NTRS)
Lee, M. C.
1985-01-01
Acoustic and electromagnetic fields applied. In contactless processing apparatus, acoustic and electromagnetic levitating fields employed alternately or simultaneously with amplitude of each controlled to produce various combinations of heating, cooling, and levitation. Apparatus provides rapid heating and cooling or slow heating and cooling for such processes as nucleation, crystallization, incubation, deep undercooling, and heterogeneity control.
Interior. Apparatus used in crushing and processing plant fibers to ...
Interior. Apparatus used in crushing and processing plant fibers to extract latex from the sap during experiments to find native North American plant which would yield sufficiently high percentage of latex to produce natural rubber. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
Hybrid adsorptive membrane reactor
NASA Technical Reports Server (NTRS)
Tsotsis, Theodore T. (Inventor); Sahimi, Muhammad (Inventor); Fayyaz-Najafi, Babak (Inventor); Harale, Aadesh (Inventor); Park, Byoung-Gi (Inventor); Liu, Paul K. T. (Inventor)
2011-01-01
A hybrid adsorbent-membrane reactor in which the chemical reaction, membrane separation, and product adsorption are coupled. Also disclosed are a dual-reactor apparatus and a process using the reactor or the apparatus.
Hybrid adsorptive membrane reactor
Tsotsis, Theodore T [Huntington Beach, CA; Sahimi, Muhammad [Altadena, CA; Fayyaz-Najafi, Babak [Richmond, CA; Harale, Aadesh [Los Angeles, CA; Park, Byoung-Gi [Yeosu, KR; Liu, Paul K. T. [Lafayette Hill, PA
2011-03-01
A hybrid adsorbent-membrane reactor in which the chemical reaction, membrane separation, and product adsorption are coupled. Also disclosed are a dual-reactor apparatus and a process using the reactor or the apparatus.
Interior. Plantcrushing and fiberprocessing apparatus used in latexextraction experiments. ...
Interior. Plant-crushing and fiber-processing apparatus used in latex-extraction experiments. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
Third-generation intelligent IR focal plane arrays
NASA Astrophysics Data System (ADS)
Caulfield, H. John; Jack, Michael D.; Pettijohn, Kevin L.; Schlesselmann, John D.; Norworth, Joe
1998-03-01
SBRC is at the forefront of industry in developing IR focal plane arrays including multi-spectral technology and '3rd generation' functions that mimic the human eye. 3rd generation devices conduct advanced processing on or near the FPA that serve to reduce bandwidth while performing needed functions such as automatic target recognition, uniformity correction and dynamic range enhancement. These devices represent a solution for processing the exorbitantly high bandwidth coming off large area FPAs without sacrificing systems sensitivity. SBRC's two-color approach leverages the company's HgCdTe technology to provide simultaneous multiband coverage, from short through long wave IR, with near theoretical performance. IR systems that are sensitive to different spectral bands achieve enhanced capabilities for target identification and advanced discrimination. This paper will provide a summary of the issues, the technology and the benefits of SBRC's third generation smart and two-color FPAs.
Mass transfer apparatus and method for separation of gases
Blount, Gerald C.
2015-10-13
A process and apparatus for separating components of a source gas is provided in which more soluble components of the source gas are dissolved in an aqueous solvent at high pressure. The system can utilize hydrostatic pressure to increase solubility of the components of the source gas. The apparatus includes gas recycle throughout multiple mass transfer stages to improve mass transfer of the targeted components from the liquid to gas phase. Separated components can be recovered for use in a value added application or can be processed for long-term storage, for instance in an underwater reservoir.
Mass transfer apparatus and method for separation of gases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blount, Gerald C.; Gorensek, Maximilian Boris; Hamm, Luther L.
A process and apparatus for separating components of a source gas is provided in which more soluble components of the source gas are dissolved in an aqueous solvent at high pressure. The system can utilize hydrostatic pressure to increase solubility of the components of the source gas. The apparatus includes gas recycle throughout multiple mass transfer stages to improve mass transfer of the targeted components from the liquid to gas phase. Separated components can be recovered for use in a value added application or can be processed for long-term storage, for instance in an underwater reservoir.
Method and Apparatus for Evaluating the Visual Quality of Processed Digital Video Sequences
NASA Technical Reports Server (NTRS)
Watson, Andrew B. (Inventor)
2002-01-01
A Digital Video Quality (DVQ) apparatus and method that incorporate a model of human visual sensitivity to predict the visibility of artifacts. The DVQ method and apparatus are used for the evaluation of the visual quality of processed digital video sequences and for adaptively controlling the bit rate of the processed digital video sequences without compromising the visual quality. The DVQ apparatus minimizes the required amount of memory and computation. The input to the DVQ apparatus is a pair of color image sequences: an original (R) non-compressed sequence, and a processed (T) sequence. Both sequences (R) and (T) are sampled, cropped, and subjected to color transformations. The sequences are then subjected to blocking and discrete cosine transformation, and the results are transformed to local contrast. The next step is a time filtering operation which implements the human sensitivity to different time frequencies. The results are converted to threshold units by dividing each discrete cosine transform coefficient by its respective visual threshold. At the next stage the two sequences are subtracted to produce an error sequence. The error sequence is subjected to a contrast masking operation, which also depends upon the reference sequence (R). The masked errors can be pooled in various ways to illustrate the perceptual error over various dimensions, and the pooled error can be converted to a visual quality measure.
Fiducial Marker Detection and Pose Estimation From LIDAR Range Data
2010-03-01
of View FPA Focal Plane Array FPS Frames Per Second FRE Fiducial Registration Error GIS Geographic Information Systems GPS Global...applications to image analysis and automated cartography. Communications of the ACM, 24(6), 381–395. Bradski, G., & Kaehler, A. (2008). Learning OpenCV
77 FR 2963 - Commission Information Collection Activities (FERC-725F); Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-20
... submitting the information collection FERC-725F, ``Mandatory Reliability Standards for Nuclear Plant...: Title: FERC-725F Mandatory Reliability Standards for Nuclear Plant Interface Coordination OMB Control No... added a new section 215 to the FPA, which required a Commission-certified Electric Reliability...
76 FR 67158 - Commission Information Collection Activities (FERC-725F); Comment Request; Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-31
..., ``Mandatory Reliability Standard for Nuclear Plant Interface Coordination'' (OMB Control No. 1902-0249), is... 215 to the FPA, which required a Commission-certified Electric Reliability Organization (ERO) to develop mandatory and enforceable Reliability Standards, which are subject to Commission review and...
Hsieh, Hong-Jung; Hu, Chih-Chung; Lu, Tung-Wu; Lu, Hsuan-Lun; Kuo, Mei-Ying; Kuo, Chien-Chung; Hsu, Horng-Chaung
2016-06-07
Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method proposed by Fujie et al. (J Biomech Eng 115(3):211-7, 1993) focused on anterior/posterior tests. Its convergence and applicability on other clinically relevant DOFs such as valgus/varus have not been demonstrated. The current s1tudy aimed to develop a 6-DOF RJTS using an industrial robot, to propose two new force-position hybrid control methods, and to evaluate the performance of the methods and FPH in controlling the RJTS for anterior/posterior and valgus/varus laxity tests of the knee joint. An RJTS was developed using an industrial 6-DOF robot with a 6-component load-cell attached at the effector. The performances of FPH and two new control methods, namely force-position alternate control (FPA) and force-position hybrid control with force-moment control (FPHFM), for unconstrained anterior/posterior and valgus/varus laxity tests were evaluated and compared with traditional constrained tests (CT) in terms of the number of control iterations, total time and the constraining forces and moments. As opposed to CT, the other three control methods successfully reduced the constraining forces and moments for both anterior/posterior and valgus/varus tests, FPHFM being the best followed in order by FPA and FPH. FPHFM had root-mean-squared constraining forces and moments of less than 2.2 N and 0.09 Nm, respectively at 0° flexion, and 2.3 N and 0.14 Nm at 30° flexion. The corresponding values for FPH were 8.5 N and 0.33 Nm, and 11.5 N and 0.45 Nm, respectively. Given the same control parameters including the compliance matrix, FPHFM and FPA reduced the constraining loads of FPH at the expense of additional control iterations, and thus increased total time, FPA taking about 10 % longer than FPHFM. The FPHFM would be the best choice among the methods considered when longer total time is acceptable in the intended clinical applications. The current results will be useful for selecting a force-position hybrid control method for unconstrained laxity tests using an RJTS.
Thermocatalytic process for CO.sub.2-free production of hydrogen and carbon from hydrocarbons
Muradov, Nazim Z [Melbourne, FL
2011-08-23
A novel process and apparatus are disclosed for sustainable CO.sub.2-free production of hydrogen and carbon by thermocatalytic decomposition (dissociation, pyrolysis, cracking) of hydrocarbon fuels over carbon-based catalysts in the absence of air and/or water. The apparatus and thermocatalytic process improve the activity and stability of carbon catalysts during the thermocatalytic process and produce both high purity hydrogen (at least, 99.0 volume %) and carbon, from any hydrocarbon fuel, including sulfurous fuels. In a preferred embodiment, production of hydrogen and carbon is achieved by both internal and external activation of carbon catalysts. Internal activation of carbon catalyst is accomplished by recycling of hydrogen-depleted gas containing unsaturated and aromatic hydrocarbons back to the reactor. External activation of the catalyst can be achieved via surface gasification with hot combustion gases during catalyst heating. The process and apparatus can be conveniently integrated with any type of fuel cell to generate electricity.
Integrated coke, asphalt and jet fuel production process and apparatus
Shang, Jer Y.
1991-01-01
A process and apparatus for the production of coke, asphalt and jet fuel m a feed of fossil fuels containing volatile carbon compounds therein is disclosed. The process includes the steps of pyrolyzing the feed in an entrained bed pyrolyzing means, separating the volatile pyrolysis products from the solid pyrolysis products removing at least one coke from the solid pyrolysis products, fractionating the volatile pyrolysis products to produce an overhead stream and a bottom stream which is useful as asphalt for road pavement, condensing the overhead stream to produce a condensed liquid fraction and a noncondensable, gaseous fraction, and removing water from the condensed liquid fraction to produce a jet fuel-containing product. The disclosed apparatus is useful for practicing the foregoing process. the process provides a useful method of mass producing and jet fuels from materials such as coal, oil shale and tar sands.
Improved Position Sensor for Feedback Control of Levitation
NASA Technical Reports Server (NTRS)
Hyers, Robert; Savage, Larry; Rogers, Jan
2004-01-01
An improved optoelectronic apparatus has been developed to provide the position feedback needed for controlling the levitation subsystem of a containerless-processing system. As explained, the advantage of this apparatus over prior optoelectronic apparatuses that have served this purpose stems from the use of an incandescent lamp, instead of a laser, to illuminate the levitated object. In containerless processing, a small object to be processed is levitated (e.g., by use of a microwave, low-frequency electromagnetic, electrostatic, or acoustic field) so that it is not in contact with the wall of the processing chamber or with any other solid object during processing. In the case of electrostatic or low-frequency electromagnetic levitation, real-time measurement of the displacement of the levitated object from its nominal levitation position along the vertical axis (and, in some cases, along one or two horizontal axes) is needed for feedback control of the levitating field.
Tissue culture apparatus for flight experimentation
NASA Technical Reports Server (NTRS)
Scheld, H. W.; Magnuson, J. W.; Krikorian, A. D.
1985-01-01
The development of an apparatus for in-flight treatment of cells, tissues, or small organisms for microscopic and chemical analyses is discussed. The hardware for the apparatus is to have: (1) automated functions, (2) the capability to interface with ground-based facilities, (3) independently controlled chambers, (4) variable chamber configurations and volumes, and (4) the capabilities for processing the materials. The components of the equipment used on Skylab 3 for the study of animal cells are described. The design of an apparatus which incorporates all the required capabilities is proposed.
NASA Astrophysics Data System (ADS)
Diawati, Chansyanah; Liliasari, Setiabudi, Agus; Buchari
2017-05-01
This project-based learning combined the chemistry of separation process using steam distillation with engineering design process in an undergraduate chemistry course. Students built upon their knowledge of phase changes, immiscible mixture, and the relationship between vapor pressure and boiling point to complete a project of modifications steam distillation apparatus. The research method is a qualitative case study, which aims to describe how (1) the creative thinking skills of students emerged during six weeks of theproject, (2) students built steam distillation apparatus characteristics as the project product and (3) students response to the project-based learning model. The results showed that the students had successfully constructed a steam distillation apparatus using plastic kettle as steam generator and distillation flask. A Plastic tubewas used to drain water vapor from steam generator to distillation flask and to drain steam containing essential oil to the condenser. A biscuit tin filled with ice was used as a condenser. The time required until resulting distillate was fifteen minutes. The production of essential was conductive qualitatively by a very strong smell typical of essential oil and two phases of distillate. Throughout the project, students formulated the relevant and varied problem, formulated the goals, proposed the ideas of the apparatus and materials, draw apparatus design, constructed apparatus, tested apparatus, evaluated, and reported the project. Student response was generally positive. They were pleased, interested, more understanding the concepts and work apparatus principles, also implemented new ideas. These results indicate that project-based learning can develop students' creative thinking skills. Based on these results, it is necessary to conduct research and implemented project-based learning to other concepts.
Improved soft-agar colony assay in a fluid processing apparatus.
Forsman, A D; Herpich, A R; Chapes, S K
1999-01-01
The standard method for quantitating bone marrow precursor cells has been to count the number of colony-forming units that form in semisolid (0.3%) agar. Recently we adapted this assay for use in hardware, the Fluid Processing Apparatus, that is flown in standard payload lockers of the space shuttle. When mouse or rat macrophage colony-forming units were measured with this hardware in ground-based assays, we found significantly more colony growth than that seen in standard plate assays. The improved growth correlates with increased agar thickness but also appears to be due to properties inherent to the Fluid Processing Apparatus. This paper describes an improved method for determining bone marrow macrophage precursor numbers in semisolid agar.
Processes, data structures, and apparatuses for representing knowledge
Hohimer, Ryan E [West Richland, WA; Thomson, Judi R [Guelph, CA; Harvey, William J [Richland, WA; Paulson, Patrick R [Pasco, WA; Whiting, Mark A [Richland, WA; Tratz, Stephen C [Richland, WA; Chappell, Alan R [Seattle, WA; Butner, R Scott [Richland, WA
2011-09-20
Processes, data structures, and apparatuses to represent knowledge are disclosed. The processes can comprise labeling elements in a knowledge signature according to concepts in an ontology and populating the elements with confidence values. The data structures can comprise knowledge signatures stored on computer-readable media. The knowledge signatures comprise a matrix structure having elements labeled according to concepts in an ontology, wherein the value of the element represents a confidence that the concept is present in an information space. The apparatus can comprise a knowledge representation unit having at least one ontology stored on a computer-readable medium, at least one data-receiving device, and a processor configured to generate knowledge signatures by comparing datasets obtained by the data-receiving devices to the ontologies.
Continuous steel production and apparatus
Peaslee, Kent D [Rolla, MO; Peter, Jorg J [McMinnville, OR; Robertson, David G. C. [Rolla, MO; Thomas, Brian G [Champaign, IL; Zhang, Lifeng [Trondheim, NO
2009-11-17
A process for continuous refining of steel via multiple distinct reaction vessels for melting, oxidation, reduction, and refining for delivery of steel continuously to, for example, a tundish of a continuous caster system, and associated apparatus.
Apparatus for recovering gaseous hydrocarbons from hydrocarbon-containing solid hydrates
Elliott, Guy R. B.; Barraclough, Bruce L.; Vanderborgh, Nicholas E.
1984-01-01
A method and apparatus are provided for producing gaseous hydrocarbons from formations comprising solid hydrocarbon hydrates located under either a body of land or a body of water. The vast natural resources of such hydrocarbon hydrates can thus now be economically mined. Relatively warm brine or water is brought down from an elevation above that of the hydrates through a portion of the apparatus and passes in contact with the hydrates, thus melting them. The liquid then continues up another portion of the apparatus, carrying entrained hydrocarbon vapors in the form of bubbles, which can easily be separated from the liquid. After a short startup procedure, the process and apparatus are substantially self-powered.
Materials processing apparatus development for fluoride glass
NASA Technical Reports Server (NTRS)
Smith, Guy A.; Kosten, Sue; Workman, Gary L.
1994-01-01
Fluoride glasses have great potential for optical fiber communications due to the high transmittance when no microcrystallites occur during drawing operations. This work has developed apparatus to test the occurrence of microcrystallites during recrystallization in reduced gravity on the KC-135. The apparatus allows fluoride glass fiber, such as ZBLAN, to be melted and recrystallized during both the low and high g portions the parabolic flight.
Improved Linear-Ion-Trap Frequency Standard
NASA Technical Reports Server (NTRS)
Prestage, John D.
1995-01-01
Improved design concept for linear-ion-trap (LIT) frequency-standard apparatus proposed. Apparatus contains lengthened linear ion trap, and ions processed alternately in two regions: ions prepared in upper region of trap, then transported to lower region for exposure to microwave radiation, then returned to upper region for optical interrogation. Improved design intended to increase long-term frequency stability of apparatus while reducing size, mass, and cost.
50 CFR 221.2 - What terms are used in this part?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 221.2 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS PRESCRIPTIONS IN FERC HYDROPOWER LICENSES General... Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Intervention means a...
76 FR 49469 - Orlando Utilities Commission; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. NJ11-15-000] Orlando Utilities Commission; Notice of Filing Take notice that on July 29, 2011, Orlando Utilities Commission (OUC), pursuant to section 205 of the Federal Power Act (FPA) \\1\\ and Part 35 of the Federal Energy Regulatory...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-01
... by the FERC-725D, ``Facilities Design, Connections and Maintenance Reliability Standards'' (OMB... 2005 added a new section 215 to the FPA, which required a Commission-certified Electric Reliability Organization (ERO) to develop mandatory and enforceable reliability standards, which are subject to Commission...
78 FR 49490 - Commission Information Collection Activities (Ferc-511); Comment Request; Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... information collection, FERC-511 (Transfer of Electric License). DATES: Comments on the collection of...-0873. SUPPLEMENTARY INFORMATION: Title: Transfer of Electric License. OMB Control No.: 1902-0069... utilization of power.\\2\\ Section 8 of the FPA provides that the voluntary transfer of any license is made only...
Digital Signal Processing Techniques for the GIFTS SM EDU
NASA Technical Reports Server (NTRS)
Tian, Jialin; Reisse, Robert A.; Gazarik, Michael J.
2007-01-01
The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes several digital signal processing (DSP) techniques involved in the development of the calibration model. In the first stage, the measured raw interferograms must undergo a series of processing steps that include filtering, decimation, and detector nonlinearity correction. The digital filtering is achieved by employing a linear-phase even-length FIR complex filter that is designed based on the optimum equiripple criteria. Next, the detector nonlinearity effect is compensated for using a set of pre-determined detector response characteristics. In the next stage, a phase correction algorithm is applied to the decimated interferograms. This is accomplished by first estimating the phase function from the spectral phase response of the windowed interferogram, and then correcting the entire interferogram based on the estimated phase function. In the calibration stage, we first compute the spectral responsivity based on the previous results and the ideal Planck blackbody spectra at the given temperatures, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. In the post-calibration stage, we estimate the Noise Equivalent Spectral Radiance (NESR) from the calibrated ABB and HBB spectra. The NESR is generally considered as a measure of the instrument noise performance, and can be estimated as the standard deviation of calibrated radiance spectra from multiple scans. To obtain an estimate of the FPA performance, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is developed based on the pixel performance evaluation. This would allow us to perform the calibration procedures on a random pixel population that is a good statistical representation of the entire FPA. The design and implementation of each individual component will be discussed in details.
NASA Astrophysics Data System (ADS)
Liu, Chengwei; Sui, Xiubao; Gu, Guohua; Chen, Qian
2018-02-01
For the uncooled long-wave infrared (LWIR) camera, the infrared (IR) irradiation the focal plane array (FPA) receives is a crucial factor that affects the image quality. Ambient temperature fluctuation as well as system power consumption can result in changes of FPA temperature and radiation characteristics inside the IR camera; these will further degrade the imaging performance. In this paper, we present a novel shutterless non-uniformity correction method to compensate for non-uniformity derived from the variation of ambient temperature. Our method combines a calibration-based method and the properties of a scene-based method to obtain correction parameters at different ambient temperature conditions, so that the IR camera performance can be less influenced by ambient temperature fluctuation or system power consumption. The calibration process is carried out in a temperature chamber with slowly changing ambient temperature and a black body as uniform radiation source. Enough uniform images are captured and the gain coefficients are calculated during this period. Then in practical application, the offset parameters are calculated via the least squares method based on the gain coefficients, the captured uniform images and the actual scene. Thus we can get a corrected output through the gain coefficients and offset parameters. The performance of our proposed method is evaluated on realistic IR images and compared with two existing methods. The images we used in experiments are obtained by a 384× 288 pixels uncooled LWIR camera. Results show that our proposed method can adaptively update correction parameters as the actual target scene changes and is more stable to temperature fluctuation than the other two methods.
sCMOS detector for imaging VNIR spectrometry
NASA Astrophysics Data System (ADS)
Eckardt, Andreas; Reulke, Ralf; Schwarzer, Horst; Venus, Holger; Neumann, Christian
2013-09-01
The facility Optical Information Systems (OS) at the Robotics and Mechatronics Center of the German Aerospace Center (DLR) has more than 30 years of experience with high-resolution imaging technology. This paper shows the scientific results of the institute of leading edge instruments and focal plane designs for EnMAP VIS/NIR spectrograph. EnMAP (Environmental Mapping and Analysis Program) is one of the selected proposals for the national German Space Program. The EnMAP project includes the technological design of the hyper spectral space borne instrument and the algorithms development of the classification. The EnMAP project is a joint response of German Earth observation research institutions, value-added resellers and the German space industry like Kayser-Threde GmbH (KT) and others to the increasing demand on information about the status of our environment. The Geo Forschungs Zentrum (GFZ) Potsdam is the Principal Investigator of EnMAP. DLR OS and KT were driving the technology of new detectors and the FPA design for this project, new manufacturing accuracy and on-chip processing capability in order to keep pace with the ambitious scientific and user requirements. In combination with the engineering research, the current generations of space borne sensor systems are focusing on VIS/NIR high spectral resolution to meet the requirements on earth and planetary observation systems. The combination of large swath and high spectral resolution with intelligent synchronization control, fast-readout ADC chains and new focal-plane concepts open the door to new remote-sensing and smart deep space instruments. The paper gives an overview over the detector verification program at DLR on FPA level, new control possibilities for sCMOS detectors in global shutter mode and key parameters like PRNU, DSNU, MTF, SNR, Linearity, Spectral Response, Quantum Efficiency, Flatness and Radiation Tolerance will be discussed in detail.
Development and Production of Array Barrier Detectors at SCD
NASA Astrophysics Data System (ADS)
Klipstein, P. C.; Avnon, E.; Benny, Y.; Berkowicz, E.; Cohen, Y.; Dobromislin, R.; Fraenkel, R.; Gershon, G.; Glozman, A.; Hojman, E.; Ilan, E.; Karni, Y.; Klin, O.; Kodriano, Y.; Krasovitsky, L.; Langof, L.; Lukomsky, I.; Nevo, I.; Nitzani, M.; Pivnik, I.; Rappaport, N.; Rosenberg, O.; Shtrichman, I.; Shkedy, L.; Snapi, N.; Talmor, R.; Tessler, R.; Weiss, E.; Tuito, A.
2017-09-01
XB n or XB p barrier detectors exhibit diffusion-limited dark currents comparable with mercury cadmium telluride Rule-07 and high quantum efficiencies. In 2011, SemiConductor Devices (SCD) introduced "HOT Pelican D", a 640 × 512/15- μm pitch InAsSb/AlSbAs XB n mid-wave infrared (MWIR) detector with a 4.2- μm cut-off and an operating temperature of ˜150 K. Its low power (˜3 W), high pixel operability (>99.5%) and long mean time to failure make HOT Pelican D a highly reliable integrated detector-cooler product with a low size, weight and power. More recently, "HOT Hercules" was launched with a 1280 × 1024/15- μm format and similar advantages. A 3-megapixel, 10- μm pitch version ("HOT Blackbird") is currently completing development. For long-wave infrared applications, SCD's 640 × 512/15- μm pitch "Pelican-D LW" XB p type II superlattice (T2SL) detector has a ˜9.3- μm cut-off wavelength. The detector contains InAs/GaSb and InAs/AlSb T2SLs, and is fabricated into focal plane array (FPA) detectors using standard production processes including hybridization to a digital silicon read-out integrated circuit (ROIC), glue underfill and substrate thinning. The ROIC has been designed so that the complete detector closely follows the interfaces of SCD's MWIR Pelican-D detector family. The Pelican-D LW FPA has a quantum efficiency of ˜50%, and operates at 77 K with a pixel operability of >99% and noise equivalent temperature difference of 13 mK at 30 Hz and F/2.7.
Tomczuk, Zygmunt; Miller, William E.; Wolson, Raymond D.; Gay, Eddie C.
1991-01-01
An electrochemical process and apparatus for the recovery of uranium and plutonium from spent metal clad fuel pins is disclosed. The process uses secondary reactions between U.sup.+4 cations and elemental uranium at the anode to increase reaction rates and improve anodic efficiency compared to prior art processes. In another embodiment of the process, secondary reactions between Cd.sup.+2 cations and elemental uranium to form uranium cations and elemental cadmium also assists in oxidizing the uranium at the anode.
Method and apparatus for implementing material thermal property measurement by flash thermal imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Jiangang
A method and apparatus are provided for implementing measurement of material thermal properties including measurement of thermal effusivity of a coating and/or film or a bulk material of uniform property. The test apparatus includes an infrared camera, a data acquisition and processing computer coupled to the infrared camera for acquiring and processing thermal image data, a flash lamp providing an input of heat onto the surface of a two-layer sample with an enhanced optical filter covering the flash lamp attenuating an entire infrared wavelength range with a series of thermal images is taken of the surface of the two-layer sample.
Apparatus and method for implementing power saving techniques when processing floating point values
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Moon; Park, Sang Phill
An apparatus and method are described for reducing power when reading and writing graphics data. For example, one embodiment of an apparatus comprises: a graphics processor unit (GPU) to process graphics data including floating point data; a set of registers, at least one of the registers of the set partitioned to store the floating point data; and encode/decode logic to reduce a number of binary 1 values being read from the at least one register by causing a specified set of bit positions within the floating point data to be read out as 0s rather than 1s.
Particle-free microchip processing
Geller, Anthony S.; Rader, Daniel J.
1996-01-01
Method and apparatus for reducing particulate contamination in microchip processing are disclosed. The method and apparatus comprise means to reduce particle velocity toward the wafer before the particles can be deposited on the wafer surface. A reactor using electric fields to reduce particle velocity and prevent particulate contamination is disclosed. A reactor using a porous showerhead to reduce particle velocities and prevent particulate contamination is disclosed.
Use of low temperature blowers for recirculation of hot gases
Maru, H.C.; Forooque, M.
1982-08-19
An apparatus is described for maintaining motors at low operating temperatures during recirculation of hot gases in fuel cell operations and chemical processes such as fluidized bed coal gasification. The apparatus includes a means for separating the hot process gas from the motor using a secondary lower temperature gas, thereby minimizing the temperature increase of the motor and associated accessories.
Operational experience of the OC-OTEC experiments at NELH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Link, H
1989-02-01
The Solar Energy Research Institute, under funding and program direction from the US Department of Energy, has been operating a small-scale test apparatus to investigate key components of open- cycle ocean thermal energy conversion (OC-OTEC). The apparatus started operations in October 1987 and continues to provide valuable information on heat-and mass-transfer processes in evaporators and condensers, gas sorption processes as seawater is depressurized and repressurized, and control and instrumentation characteristics of open-cycle systems. Although other test facilities have been used to study some of these interactions, this is the largest apparatus of its kind to use seawater since Georges Claude`smore » efforts in 1926. The information obtained from experiments conducted in this apparatus is being used to design a larger scale experiment in which a positive net power production is expected to be demonstrated for the first time with OC-OTEC. This paper describes the apparatus, the major tests conducted during its first 18 months of operation, and the experience gained in OC-OTEC system operation. 13 refs., 8 figs.« less
Apparatus for high flux photocatalytic pollution control using a rotating fluidized bed reactor
Tabatabaie-Raissi, Ali; Muradov, Nazim Z.; Martin, Eric
2003-06-24
An apparatus based on optimizing photoprocess energetics by decoupling of the process energy efficiency from the DRE for target contaminants. The technique is applicable to both low- and high-flux photoreactor design and scale-up. An apparatus for high-flux photocatalytic pollution control is based on the implementation of multifunctional metal oxide aerogels and other media in conjunction with a novel rotating fluidized particle bed reactor.
Torczynski, John R.
2000-01-01
A spin coating apparatus requires less cleanroom air flow than prior spin coating apparatus to minimize cleanroom contamination. A shaped exhaust duct from the spin coater maintains process quality while requiring reduced cleanroom air flow. The exhaust duct can decrease in cross section as it extends from the wafer, minimizing eddy formation. The exhaust duct can conform to entrainment streamlines to minimize eddy formation and reduce interprocess contamination at minimal cleanroom air flow rates.
Recording 360 Degree Holograms in the Undergraduate Laboratory
ERIC Educational Resources Information Center
Stirn, Bradley A.
1975-01-01
Describes an experiment for recording holograms using a minimum of costly apparatus. Includes a description of apparatus and materials, the procedure for recording the hologram, the processing of the hologram, and the reconstruction of the image. (GS)
Apparatus for processing electromagnetic radiation and method
NASA Technical Reports Server (NTRS)
Gatewood, George D. (Inventor)
1983-01-01
Measuring apparatus including a ruled member having alternate transparent and opaque zones. An optical coupler connecting the ruled member with electromagnetic radiation-conversion apparatus. The conversion apparatus may include a photomultiplier and a discriminator. Radiation impinging on the ruled member will, in part, be converted to electrical pulses which correspond to the intensity of the radiation. A method of processing electromagnetic radiation includes providing a member having alternating dark and light zones, establishing movement of the member through the beam of electromagnetic radiation with the dark zones interrupting passage of radiation through the rule, providing an optical coupler to connect a portion of the radiation with a conversion station where the radiation portion is converted into an electrical pulse which is related to the intensity of the radiation received at the conversion station. The electrical pulses may be counted and the digitized signals stored or permanently recorded to produce positional information.
Elliott, G.R.B.; Barraclough, B.L.; Vanderborgh, N.E.
1981-02-19
A method and apparatus are provided for producing gaseous hydrocarbons from formations comprising solid hydrocarbon hydrates located under either a body of land or a body of water. The vast natural resources of such hydrocarbon hydrates can thus now be economically mined. Relatively warm brine or water is brought down from an elevation above that of the hydrates through a portion of the apparatus, and passes in contact with the hydrates, thus melting them. The liquid then continues up another portion of the apparatus carrying entrained hydrocarbon vapors in the form of bubbles, which can easily be separated from the liquid. After a short startup procedure, the process and apparatus are substantially self-powered.
Elliott, Guy R. B.; Barraclough, Bruce L.; Vanderborgh, Nicholas E.
1983-01-01
A method and apparatus are provided for producing gaseous hydrocarbons from formations comprising solid hydrocarbon hydrates located under either a body of land or a body of water. The vast natural resources of such hydrocarbon hydrates can thus now be economically mined. Relatively warm brine or water is brought down from an elevation above that of the hydrates through a portion of the apparatus and passes in contact with the hydrates, thus melting them. The liquid then continues up another portion of the apparatus, carrying entrained hydrocarbon vapors in the form of bubbles, which can easily be separated from the liquid. After a short startup procedure, the process and apparatus are substantially self-powered.
Suborbital missions: The Joust
NASA Technical Reports Server (NTRS)
Ferguson, Bruce W.
1991-01-01
Joust 1 will carry a payload of 10 experiments. The experiments in the payload module will be mated with a service module containing accelerometers, avionics, a low gravity rate control system, and battery packs. This suborbital mission will last approximately 21 minutes, providing at least 13 minutes of microgravity time. The experiments are as follow: study into polymer membrane processes; polymer curing; plasma particle generation; automated generic bioprocessing apparatus; biomodule; thin films; materials dispersion apparatus; foam formation; electrodeposition process; and powdered materials processing.
Ionomer-Membrane Water Processing Apparatus
NASA Technical Reports Server (NTRS)
MacCallum, Taber K. (Inventor); Kelsey, Laura (Inventor)
2016-01-01
This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion(Registered Trademark), over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.
Ionomer-Membrane Water Processing Apparatus
NASA Technical Reports Server (NTRS)
MacCallum, Taber K. (Inventor); Kelsey, Laura Katrina (Inventor)
2017-01-01
This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion.RTM., over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.
Preparation for microgravity: The role of the microgravity materials science laboratory
NASA Technical Reports Server (NTRS)
Johnston, J. Christopher; Rosenthal, Bruce N.; Meyer, Maryjo B.; Glasgow, Thomas K.
1988-01-01
A laboratory dedicated to ground based materials processing in preparation for space flight was established at the NASA Lewis Research Center. Experiments are performed to delineate the effects of gravity on processes of both scientific and commercial interest. Processes are modeled physically and mathematically. Transport model systems are used where possible to visually track convection, settling, crystal growth, phase separation, agglomeration, vapor transport, diffusive flow, and polymers reactions. The laboratory contains apparatus which functionally duplicates apparatus available for flight experiments and other pieces instrumented specifically to allow process characterization. Materials addressed include metals, alloys, salts, glasses, ceramics, and polymers. The Microgravity Materials Science Laboratory is staffed by engineers and technicians from a variety of disciplines and is open to users from industry and academia as well as the government. Examples will be given of the laboratory apparatus typical experiments and results.
Broadband unidirectional ultrasound propagation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinha, Dipen N.; Pantea, Cristian
A passive, linear arrangement of a sonic crystal-based apparatus and method including a 1D sonic crystal, a nonlinear medium, and an acoustic low-pass filter, for permitting unidirectional broadband ultrasound propagation as a collimated beam for underwater, air or other fluid communication, are described. The signal to be transmitted is first used to modulate a high-frequency ultrasonic carrier wave which is directed into the sonic crystal side of the apparatus. The apparatus processes the modulated signal, whereby the original low-frequency signal exits the apparatus as a collimated beam on the side of the apparatus opposite the sonic crystal. The sonic crystalmore » provides a bandpass acoustic filter through which the modulated high-frequency ultrasonic signal passes, and the nonlinear medium demodulates the modulated signal and recovers the low-frequency sound beam. The low-pass filter removes remaining high-frequency components, and contributes to the unidirectional property of the apparatus.« less
Pulsed atmospheric fluidized bed combustor apparatus and process
Mansour, Momtaz N.
1992-01-01
A pulsed atmospheric fluidized bed reactor system is disclosed and claimed along with a process for utilization of same for the combustion of, e.g. high sulfur content coal. The system affords a economical, ecologically acceptable alternative to oil and gas fired combustors. The apparatus may also be employed for endothermic reaction, combustion of waste products, e.g. organic and medical waste, drying, calcining and the like.
Particle-free microchip processing
Geller, A.S.; Rader, D.J.
1996-06-04
Method and apparatus for reducing particulate contamination in microchip processing are disclosed. The method and apparatus comprise means to reduce particle velocity toward the wafer before the particles can be deposited on the wafer surface. A reactor using electric fields to reduce particle velocity and prevent particulate contamination is disclosed. A reactor using a porous showerhead to reduce particle velocities and prevent particulate contamination is disclosed. 5 figs.
Method and apparatus for lysing and processing algae
Chew, Geoffrey; Reich, Alton J.; Dykes, Jr., H. Waite H.; Di Salvo, Roberto
2013-03-05
Methods and apparatus for processing algae are described in which a hydrophilic ionic liquid is used to lyse algae cells at lower temperatures than existing algae processing methods. A salt or salt solution is used as a separation agent and to remove water from the ionic liquid, allowing the ionic liquid to be reused. The used salt may be dried or concentrated and reused. The relatively low lysis temperatures and recycling of the ionic liquid and salt reduce the environmental impact of the algae processing while providing biofuels and other useful products.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-15
... Tidal Power, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications December 8, 2010. On November 22, 2010, Pennamaquan Tidal... Act (FPA), proposing to study the feasibility of the Pennamaquan Tidal Power Plant Project to be...
43 CFR 45.2 - What terms are used in this part?
Code of Federal Regulations, 2012 CFR
2012-10-01
... Department of the Interior, including any bureau, unit, or office of the Department, whether in Washington... Federal Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Hearings... impact statement issued to comply with the requirements of the National Environmental Policy Act of 1969...
43 CFR 45.2 - What terms are used in this part?
Code of Federal Regulations, 2014 CFR
2014-10-01
... Department of the Interior, including any bureau, unit, or office of the Department, whether in Washington... Federal Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Hearings... impact statement issued to comply with the requirements of the National Environmental Policy Act of 1969...
43 CFR 45.2 - What terms are used in this part?
Code of Federal Regulations, 2011 CFR
2011-10-01
... Department of the Interior, including any bureau, unit, or office of the Department, whether in Washington... Federal Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Hearings... impact statement issued to comply with the requirements of the National Environmental Policy Act of 1969...
43 CFR 45.2 - What terms are used in this part?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Department of the Interior, including any bureau, unit, or office of the Department, whether in Washington... Federal Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Hearings... impact statement issued to comply with the requirements of the National Environmental Policy Act of 1969...
43 CFR 45.2 - What terms are used in this part?
Code of Federal Regulations, 2013 CFR
2013-10-01
... Department of the Interior, including any bureau, unit, or office of the Department, whether in Washington... Federal Energy Regulatory Commission. FPA means the Federal Power Act, 16 U.S.C. 791 et seq. Hearings... impact statement issued to comply with the requirements of the National Environmental Policy Act of 1969...
78 FR 34361 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric corporate filings: Docket Numbers: EC13-111-000. Applicants: CPV Shore, LLC. Description: Application Under FPA Section 203 of CPV Shore, LLC (ArcLight). Filed Date: 5/31/13. Accession Number:...
78 FR 65639 - Notice of Filing; Wyrsch, Martha B.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... Filing; Wyrsch, Martha B. Take notice that on October 25, 2013, Martha B. Wyrsch submitted for filing, an application for authority to hold interlocking positions, pursuant to section 305(b) of the Federal Power Act (FPA), 16 U.S.C. 825d(b) and Part 45 of the Federal Energy Regulatory Commission's (Commission) Rules...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-08
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13102-000] Birch Power... Intervene, and Competing Applications On December 1, 2011, Birch Power Company filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to study the...
75 FR 28001 - Ken Willis; Notice of Authorization for Continued Project Operation
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-19
..., licensee for the Fire Mountain Lodge Hydroelectric Project, filed an Application for a New License pursuant to the Federal Power Act (FPA) and the Commission's regulations thereunder. The Fire Mountain Lodge..., notice is hereby given that Ken Willis is authorized to continue operation of the Fire Mountain Lodge...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-09
...), as amended by HREA.... The facility is constructed, operated, or maintained Y for the generation of... Conduit Hydropower Facility Satisfies (Y/ Statutory provision Description N) FPA 30(a)(3)(A), as amended by HREA....... The conduit the facility uses is a tunnel, canal, Y pipeline, aqueduct, flume, ditch...
77 FR 28863 - Commission Information Collection Activities (FERC-915); Comment Request; Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-16
... under section 205 of the Federal Power Act (FPA) to ensure that wholesale sales of electricity are just... maintained by the respondents under FERC-915 to monitor the entities' sales, ensure that the prices are just and reasonable, maintain the integrity of the wholesale jurisdictional sales markets, and ensure that...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-17
... with the project. Applicant Contact: Daniel R. Irvin, Free Flow Power Corporation, 33 Commercial Street... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13876-000] South Run Pumped... the Federal Power Act (FPA), proposing to study the feasibility of the South Run Pumped Storage...
78 FR 43191 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-19
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric corporate filings: Docket Numbers: EC13-127-000. Applicants: Astoria Energy II LLC. Description: Application under FPA Section 203 of Astoria Energy II LLC. Filed Date: 7/11/13. Accession Number:...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... International Consortium of Energy Managers; Notice of Preliminary Permit Application Accepted for Filing and... Consortium of Energy Managers filed an application, pursuant to section 4(f) of the Federal Power Act (FPA...: Rexford Wait, International Consortium of Energy Managers, 2416 Cades Way, Vista, CA 92083; (760) 599-0086...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-16
... Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On September 25, 2013, Mid-Atlantic Hydro, LLC, filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-17
... Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On February 19, 2013, Hamilton Street Hydro, LLC, filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... 25, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On September 30, 2010, Qualified Hydro 25, LLC filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On August 16, 2013, Mid-Atlantic Hydro, LLC filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-18
... Hydropower LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On August 14, 2013, Houtama Hydropower LLC filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-18
... Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On September 9, 2013, Mid-Atlantic Hydro, LLC, filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On March 26, 2013, Hamilton Street Hydro, LLC, filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-17
... Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On February 19, 2013, Hamilton Street Hydro, LLC, filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
... Renewables, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On March 1, 2013, Basin Farm Renewables, LLC filed an application for a successive preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13863-000] Mount Storm..., Motions To Intervene, and Competing Applications January 6, 2011. On October 14, 2010, Mount Storm Hydro... (FPA), proposing to study the feasibility of the Mount Storm Pumped Storage Project to be located near...
75 FR 45607 - Application To Export Electric Energy; Manitoba Hydro
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-03
... that the proposed action will not adversely impact on the reliability of the U.S. electric power supply... United States to Canada pursuant to section 202(e) of the Federal Power Act (FPA). DATES: Comments... electric energy from the United States to Canada as a power marketer using existing international...
USDA-ARS?s Scientific Manuscript database
The chemical imaging of cotton fibers and common contaminants in fibers is presented. Chemical imaging was performed with an infrared microscope equipped with a Focal-Plane Array (FPA) detector. Infrared spectroscopy can provide us with information on the structure and quality of cotton fibers. In a...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-14
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 14065-000] Amnor Hydro West... Act (FPA), proposing to study the feasibility of the Clear Creek Dam Hydropower Project (project) to...' express permission. The proposed project would utilize the existing outlet works of the U.S. Bureau of...
78 FR 5256 - Annual Charges for Use of Government Lands
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-25
.... Information Collection Statement 67 B. Environmental Analysis 68 C. Regulatory Flexibility Act 69 D. Document.... Background 2. Section 10(e)(1) of the Federal Power Act (FPA) requires the hydropower licensees occupying... Amendment to Section 11.21 of the Regulations Under the Federal Power Act, 56 FPC 3860, at 3863 (1976). \\4...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
... Markets, LLC, Complainant v. Public Service Company of New Mexico, Respondent; Notice of Complaint April... of the Federal Power Act (FPA), 16 U.S.C. 824e (2006), Cargill Power Markets, LLC (Complainant) filed a formal complaint against Public Service Company of New Mexico (Respondent) alleging that...
NASA Technical Reports Server (NTRS)
Gunapala, S.; Bandara, S. V.; Liu, J. K.; Hong, W.; Sundaram, M.; Maker, P. D.; Muller, R. E.
1997-01-01
In this paper, we discuss the development of this very sensitive long waelength infrared (LWIR) camera based on a GaAs/AlGaAs QWIP focal plane array (FPA) and its performance in quantum efficiency, NEAT, uniformity, and operability.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 14291-000] Green Wave Mendocino Wave Park; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments... (FPA), proposing to study the feasibility of the Green Wave Mendocino Wave Park (Mendocino Wave Project...
77 FR 11515 - Application to Export Electric Energy; NRG Power Marketing LLC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-27
... DEPARTMENT OF ENERGY [OE Docket No. EA-384] Application to Export Electric Energy; NRG Power... electric energy from the United States to Mexico pursuant to section 202(e) of the Federal Power Act (FPA... requested. The electric energy that NRGPML proposes to export to Mexico would be surplus energy purchased...
Microwave/Sonic Apparatus Measures Flow and Density in Pipe
NASA Technical Reports Server (NTRS)
Arndt, G. D.; Ngo, Phong; Carl, J. R.; Byerly, Kent A.
2004-01-01
An apparatus for measuring the rate of flow and the mass density of a liquid or slurry includes a special section of pipe instrumented with microwave and sonic sensors, and a computer that processes digitized readings taken by the sensors. The apparatus was conceived specifically for monitoring a flow of oil-well-drilling mud, but the basic principles of its design and operation are also applicable to monitoring flows of other liquids and slurries.
Demonstration of 1024x1024 pixel dual-band QWIP focal plane array
NASA Astrophysics Data System (ADS)
Gunapala, S. D.; Bandara, S. V.; Liu, J. K.; Mumolo, J. M.; Ting, D. Z.; Hill, C. J.; Nguyen, J.; Rafol, S. B.
2010-04-01
QWIPs are well known for their stability, high pixel-pixel uniformity and high pixel operability which are quintessential parameters for large area imaging arrays. In this paper we report the first demonstration of the megapixel-simultaneously-readable and pixel-co-registered dual-band QWIP focal plane array (FPA). The dual-band QWIP device was developed by stacking two multi-quantum-well stacks tuned to absorb two different infrared wavelengths. The full width at half maximum (FWHM) of the mid-wave infrared (MWIR) band extends from 4.4 - 5.1 μm and FWHM of the long-wave infrared (LWIR) band extends from 7.8 - 8.8 μm. Dual-band QWIP detector arrays were hybridized with direct injection 30 μm pixel pitch megapixel dual-band simultaneously readable CMOS read out integrated circuits using the indium bump hybridization technique. The initial dual-band megapixel QWIP FPAs were cooled to 68K operating temperature. The preliminary data taken from the first megapixel QWIP FPA has shown system NE▵T of 27 and 40 mK for MWIR and LWIR bands respectively.
Super-resolution for imagery from integrated microgrid polarimeters.
Hardie, Russell C; LeMaster, Daniel A; Ratliff, Bradley M
2011-07-04
Imagery from microgrid polarimeters is obtained by using a mosaic of pixel-wise micropolarizers on a focal plane array (FPA). Each distinct polarization image is obtained by subsampling the full FPA image. Thus, the effective pixel pitch for each polarization channel is increased and the sampling frequency is decreased. As a result, aliasing artifacts from such undersampling can corrupt the true polarization content of the scene. Here we present the first multi-channel multi-frame super-resolution (SR) algorithms designed specifically for the problem of image restoration in microgrid polarization imagers. These SR algorithms can be used to address aliasing and other degradations, without sacrificing field of view or compromising optical resolution with an anti-aliasing filter. The new SR methods are designed to exploit correlation between the polarimetric channels. One of the new SR algorithms uses a form of regularized least squares and has an iterative solution. The other is based on the faster adaptive Wiener filter SR method. We demonstrate that the new multi-channel SR algorithms are capable of providing significant enhancement of polarimetric imagery and that they outperform their independent channel counterparts.
NASA Astrophysics Data System (ADS)
Zhang, Wenyu; Yang, Yushu; Zhang, Shuai; Yu, Dejian; Chen, Yong
2018-05-01
With the growing complexity of customer requirements and the increasing scale of manufacturing services, how to select and combine the single services to meet the complex demand of the customer has become a growing concern. This paper presents a new manufacturing service composition method to solve the multi-objective optimization problem based on quality of service (QoS). The proposed model not only presents different methods for calculating the transportation time and transportation cost under various structures but also solves the three-dimensional composition optimization problem, including service aggregation, service selection, and service scheduling simultaneously. Further, an improved Flower Pollination Algorithm (IFPA) is proposed to solve the three-dimensional composition optimization problem using a matrix-based representation scheme. The mutation operator and crossover operator of the Differential Evolution (DE) algorithm are also used to extend the basic Flower Pollination Algorithm (FPA) to improve its performance. Compared to Genetic Algorithm, DE, and basic FPA, the experimental results confirm that the proposed method demonstrates superior performance than other meta heuristic algorithms and can obtain better manufacturing service composition solutions.
Han, Xiaolong; Song, Wenxia; Liu, Guodong; Li, Zhonghai; Yang, Piao; Qu, Yinbo
2017-03-01
Medium optimization and repeated fed-batch fermentation were performed to improve the cellulase productivity by P. oxalicum RE-10 in submerged fermentation. First, Plackett-Burman design (PBD) and central composite design (CCD) were used to optimize the medium for cellulase production. PBD demonstrated wheat bran and NaNO 3 had significant influences on cellulase production. The CCD results showed the maximum filter paper activity (FPA) production of 8.61U/mL could be achieved in Erlenmeyer flasks. The maximal FPA reached 12.69U/mL by submerged batch fermentation in a 7.5-L stirred tank, 1.76-fold higher than that on the original medium. Then, the repeated fed-batch fermentation strategy was performed successfully for increasing the cellulase productivity from 105.75U/L/h in batch fermentation to 158.38U/L/h. The cellulase activity and the glucan conversion of delignined corn cob residue hydrolysis had no significant difference between the enzymes sampled from different cycles of the repeated fed-batch fermentation and that from batch culture. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Future of Single- to Multi-band Detector Technologies: Review
NASA Technical Reports Server (NTRS)
Abedin, M. Nurul; Bhat, Ishwara; Gunapala, Sarath D.; Bandara, Sumith V.; Refaat, Tamer F.; Sandford, Stephen P.; Singh, Upendra N.
2006-01-01
Using classical optical components such as filters, prisms and gratings to separate the desired wavelengths before they reach the detectors results in complex optical systems composed of heavy components. A simpler system will result by utilizing a single optical system and a detector that responds separately to each wavelength band. Therefore, a continuous endeavors to develop the capability to reliably fabricate detector arrays that respond to multiple wavelength regions. In this article, we will review the state-of-the-art single and multicolor detector technologies over a wide spectral-range, for use in space-based and airborne remote sensing applications. Discussions will be focused on current and the most recently developed focal plane arrays (FPA) in addition to emphasizing future development in UV-to-Far infrared multicolor FPA detectors for next generation space-based instruments to measure water vapor and greenhouse gases. This novel detector component will make instruments designed for these critical measurements more efficient while reducing complexity and associated electronics and weight. Finally, we will discuss the ongoing multicolor detector technology efforts at NASA Langley Research Center, Jet Propulsion Laboratory, Rensselaer Polytechnic Institute, and others.
Modulate chopper technique used in pyroelectric uncooled focal plane array thermal imager
NASA Astrophysics Data System (ADS)
He, Yuqing; Jin, Weiqi; Liu, Guangrong; Gao, Zhiyun; Wang, Xia; Wang, Lingxue
2002-09-01
Pyroelectric uncooled focal plane array (FPA) thermal imager has the advantages of low cost, small size, high responsibility and can work under room temperature, so it has great progress in recent years. As a matched technique, the modulate chopper has become one of the key techniques in uncooled FPA thermal imaging system. Now the Archimedes spiral cord chopper technique is mostly used. When it works, the chopper pushing scans the detector's pixel array, thus makes the pixels being exposed continuously. This paper simulates the shape of this kind of chopper, analyses the exposure time of the detector's every pixel, and also analyses the whole detector pixels' exposure sequence. From the analysis we can get the results: the parameter of Archimedes spiral cord, the detector's thermal time constant, the detector's geometrical dimension, the relative position of the detector to the chopper's spiral cord are the system's important parameters, they will affect the chopper's exposure efficiency and uniformity. We should design the chopper's relevant parameter according to the practical request to achieve the chopper's appropriate structure.
Trifiletti, A; Bartolone, S; Scamardi, R; Pizzoleo, M A; Attinà, A; Sottilotta, G; Canobbio, V; Soraci, S; Barbera, N
1999-03-01
In this study the action of a prostaglandin, PGE1, was studied in a group of patients with peripheral arterial occlusive disease (PAOD). In 16 patients (14 men and 2 women, aged 47-70 years, mean 57 +/- 7) with PAOD, Fontaine stage IIb and III in critical ischemia, the effects on two indexes of thrombin generation and action of the endovenous administration (2 hours) of 60 micrograms of Alprostadil-PGE1 for four weeks were evaluated. In all artheriopathic patients, before and after pharmacological treatment, the following haemostatic parameters were evaluated: the prothrombin fragment 1 + 2 (F1 + 2) and the fibrinopeptide A(FPA). The patients showed plasma levels of FPA significantly decreased at the end of the treatment. On the other hand, no significant difference in plasma F1 + 2 levels was observed after treatment. These results seem to indicate that plasma F1 + 2 levels are significantly elevated, as a marker of thrombosis status, in patients with PAOD before and after treatment with PGE1.
NASA Technical Reports Server (NTRS)
Avila, Edwin M. Martinez; Muniz, Ricardo; Szafran, Jamie; Dalton, Adam
2011-01-01
Lines of code (LOC) analysis is one of the methods used to measure programmer productivity and estimate schedules of programming projects. The Launch Control System (LCS) had previously used this method to estimate the amount of work and to plan development efforts. The disadvantage of using LOC as a measure of effort is that one can only measure 30% to 35% of the total effort of software projects involves coding [8]. In the application, instead of using the LOC we are using function point for a better estimation of hours in each software to develop. Because of these disadvantages, Jamie Szafran of the System Software Branch of Control And Data Systems (NE-C3) at Kennedy Space Canter developed a web application called Function Point Analysis (FPA) Depot. The objective of this web application is that the LCS software architecture team can use the data to more accurately estimate the effort required to implement customer requirements. This paper describes the evolution of the domain model used for function point analysis as project managers continually strive to generate more accurate estimates.
Oxidative Tritium Decontamination System
Gentile, Charles A. , Guttadora, Gregory L. , Parker, John J.
2006-02-07
The Oxidative Tritium Decontamination System, OTDS, provides a method and apparatus for reduction of tritium surface contamination on various items. The OTDS employs ozone gas as oxidizing agent to convert elemental tritium to tritium oxide. Tritium oxide vapor and excess ozone gas is purged from the OTDS, for discharge to atmosphere or transport to further process. An effluent stream is subjected to a catalytic process for the decomposition of excess ozone to diatomic oxygen. One of two configurations of the OTDS is employed: dynamic apparatus equipped with agitation mechanism and large volumetric capacity for decontamination of light items, or static apparatus equipped with pressurization and evacuation capability for decontamination of heavier, delicate, and/or valuable items.
Ultrasonic Apparatus and Method to Assess Compartment Syndrome
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Ueno, Toshiaki (Inventor); Hargens, Alan R. (Inventor)
2009-01-01
A process and apparatus for measuring pressure buildup in a body compartment that encases muscular tissue. The method includes assessing the body compartment configuration and identifying the effect of pulsatible components on compartment dimensions and muscle tissue characteristics. This process is used in preventing tissue necrosis, and in decisions of whether to perform surgery on the body compartment for prevention of Compartment Syndrome. An apparatus is used for measuring pressure build-up in the body compartment having components for imparting ultrasonic waves such as a transducer, placing the transducer to impart the ultrasonic waves, capturing the imparted ultrasonic waves, mathematically manipulating the captured ultrasonic waves and categorizing pressure build-up in the body compartment from the mathematical manipulations.
Process and apparatus for obtaining samples of liquid and gas from soil
Rossabi, J.; May, C.P.; Pemberton, B.E.; Shinn, J.; Sprague, K.
1999-03-30
An apparatus and process for obtaining samples of liquid and gas from subsurface soil is provided having filter zone adjacent an external expander ring. The expander ring creates a void within the soil substrate which encourages the accumulation of soil-borne fluids. The fluids migrate along a pressure gradient through a plurality of filters before entering a first chamber. A one-way valve regulates the flow of fluid into a second chamber in further communication with a collection tube through which samples are collected at the surface. A second one-way valve having a reverse flow provides additional communication between the chambers for the pressurized cleaning and back-flushing of the apparatus. 8 figs.
Process and apparatus for obtaining samples of liquid and gas from soil
Rossabi, Joseph; May, Christopher P.; Pemberton, Bradley E.; Shinn, Jim; Sprague, Keith
1999-01-01
An apparatus and process for obtaining samples of liquid and gas from subsurface soil is provided having filter zone adjacent an external expander ring. The expander ring creates a void within the soil substrate which encourages the accumulation of soil-borne fluids. The fluids migrate along a pressure gradient through a plurality of filters before entering a first chamber. A one-way valve regulates the flow of fluid into a second chamber in further communication with a collection tube through which samples are collected at the surface. A second one-way valve having a reverse flow provides additional communication between the chambers for the pressurized cleaning and back-flushing of the apparatus.
Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J
2013-02-01
To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5. At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
A 400 KHz line rate 2048-pixel stitched SWIR linear array
NASA Astrophysics Data System (ADS)
Anchlia, Ankur; Vinella, Rosa M.; Gielen, Daphne; Wouters, Kristof; Vervenne, Vincent; Hooylaerts, Peter; Deroo, Pieter; Ruythooren, Wouter; De Gaspari, Danny; Das, Jo; Merken, Patrick
2016-05-01
Xenics has developed a family of stitched SWIR long linear arrays that operate up to 400 KHz of line rate. These arrays serve medical and industrial applications that require high line rates as well as space applications that require long linear arrays. The arrays are based on a modular ROIC design concept: modules of 512 pixels are stitched during fabrication to achieve 512, 1024 and 2048 pixel arrays. Each 512-pixel module has its own on-chip digital sequencer, analog readout chain and 4 output buffers. This modular concept enables a long array to run at a high line rates irrespective of the array length, which limits the line rate in a traditional linear array. The ROIC is flip-chipped with InGaAs detector arrays. The FPA has a pixel pitch of 12.5μm and has two pixel flavors: square (12.5μm) and rectangular (250μm). The frontend circuit is based on Capacitive Trans-impedance Amplifier (CTIA) to attain stable detector bias, and good linearity and signal integrity, especially at high speeds. The CTIA has an input auto-zero mechanism that allows to have low detector bias (<20mV). An on-chip Correlated Double Sample (CDS) facilitates removal of CTIA KTC and 1/f noise, and other offsets, achieving low noise performance. There are five gain modes in the FPA giving the full well range from 85Ke- to 40Me-. The measured input referred noise is 35e-rms in the highest gain mode. The FPA operates in Integrate While Read mode and, at a master clock rate of 60MHz and a minimum integration time of 1.4μs, achieves the highest line rate of 400 KHz. In this paper, design details and measurements results are presented in order to demonstrate the array performance.
Influence of infusion volume on the ocular hemodynamic effects of peribulbar anesthesia.
Lung, Solveig; Luksch, Alexandra; Weigert, Günther; Georgopoulos, Michael; Menapace, Rupert; Polska, Elzbieta; Garhofer, Gerhard; Findl, Oliver; Schmetterer, Leopold
2006-09-01
To test the hypothesis that ocular blood-flow response to peribulbar anesthesia can be reduced by using a smaller volume of anesthetic mixture. Departments of Ophthalmology and Clinical Pharmacology, Medical University of Vienna, Vienna, Austria. Twenty patients scheduled for bilateral age-related cataract surgery were enrolled in a prospective randomized balanced observer-masked crossover study. Two study days with a 2 mL injection volume or 5 mL injection volume used for peribulbar anesthesia were scheduled. On 1 study day, patients received the 1-dose regimen and on the other study day, when the contralateral eye had surgery, patients received the other injection volume. On both study days, the anesthetic mixture consisted of an equal amount of lidocaine, bupivacaine, and hyaluronidase independently of the injection volume. Intraocular pressure (IOP), blood pressure, and pulse rate were measured noninvasively. Ocular fundus pulsation amplitude (FPA) and peak systolic and end diastolic flow velocities in the central retinal artery were measured with laser interferometry and color Doppler imaging, respectively. The results were recorded as means +/- SD. Peribulbar anesthesia increased IOP and reduced FPA and flow velocities in the central retinal artery. The effects on IOP (5 mL, 35.1% +/- 16.0%; 2 mL, 14.1% +/- 14.1%; P<.001) and ocular hemodynamic parameters (FPA: 5 mL, -17.5% +/- 7.8%/2 mL, -7.3% +/- 7.2%, P<.001; peak systolic velocity: 5 mL, -19.5% +/- 10.7%/2 mL, -10.6% +/- 9.8%, P = .013; end diastolic velocity: 5 mL, -16.7% +/- 6.2%/2 mL, -8.4% +/- 7.3%, P = .005) were more pronounced with the 5 mL injection volume than with the 2 mL injection volume. An injection volume of 2 mL instead of 5 mL reduced the ocular blood-flow response to peribulbar anesthesia. This procedure may be used in patients with ocular vascular disease to reduce the incidence of anesthesia-induced ischemia and loss of vision.
InGaAs detectors and FPA's for a large span of applications: design and material considerations
NASA Astrophysics Data System (ADS)
Vermeiren, J. P.; Merken, P.
2017-11-01
Compared with the other Infrared detector materials, such as HgCdTe (or MCT) and lead salts (e.g.: PbS, PbSe, PbSnTe, …), the history of InGaAs FPA's is not that old. Some 25 years ago the first linear detectors were used for space missions [1,2]. During the last 15-20 years InGaAs, grown lattice matched on InP, has become the work horse for the telecommunication industry [3] and later on for passive and active imagery in the SWIR range. For longer wavelengths than 1.7 μm, III-V materials are in strong competition with SWIR MCT and till now the performance of MCT is better than high In-content InGaAs. During the last years some alternatives based on quaternary materials [4] and on Superlattice structures [5] are making gradual progress in such a way that they can yield performing Focal planes in the (near) future. As the SWIR wavelengths range covers a large variety of applications, also the FPA characteristics and mainly the ROIC properties need to be adjusted to fulfil the mission requirements with the requested performance. Additionally one has to bear in mind that the nature of SWIR radiation is completely different from what is usually encountered in IR imaging. Whereas the signal of thermal imagery in the Middle Wavelength (MWIR: [3 - 5 μm]) or Long Wavelength (LWIR: [8 - 10 μm] or [8 - 12 μm]) band is characterized by a large DC pedestal, caused by objects at ambient temperature, and a small AC signal, due to the small temperature or emissivity variations, SWIR range imagery is characterized by a large dynamic range and almost no DC signal. In this sense the SWIR imagery is resembling more the nature of Visible and NIR imaging than that of thermal imagery.
Patel, Nitesh V; Sundararajan, Sri; Keller, Irwin; Danish, Shabbar
2018-01-01
Objective: Magnetic resonance (MR)-guided stereotactic laser amygdalohippocampectomy is a minimally invasive procedure for the treatment of refractory epilepsy in patients with mesial temporal sclerosis. Limited data exist on post-ablation volumetric trends associated with the procedure. Methods: 10 patients with mesial temporal sclerosis underwent MR-guided stereotactic laser amygdalohippocampectomy. Three independent raters computed ablation volumes at the following time points: pre-ablation (PreA), immediate post-ablation (IPA), 24 hours post-ablation (24PA), first follow-up post-ablation (FPA), and greater than three months follow-up post-ablation (>3MPA), using OsiriX DICOM Viewer (Pixmeo, Bernex, Switzerland). Statistical trends in post-ablation volumes were determined for the time points. Results: MR-guided stereotactic laser amygdalohippocampectomy produces a rapid rise and distinct peak in post-ablation volume immediately following the procedure. IPA volumes are significantly higher than all other time points. Comparing individual time points within each raters dataset (intra-rater), a significant difference was seen between the IPA time point and all others. There was no statistical difference between the 24PA, FPA, and >3MPA time points. A correlation analysis demonstrated the strongest correlations at the 24PA (r=0.97), FPA (r=0.95), and 3MPA time points (r=0.99), with a weaker correlation at IPA (r=0.92). Conclusion: MR-guided stereotactic laser amygdalohippocampectomy produces a maximal increase in post-ablation volume immediately following the procedure, which decreases and stabilizes at 24 hours post-procedure and beyond three months follow-up. Based on the correlation analysis, the lower inter-rater reliability at the IPA time point suggests it may be less accurate to assess volume at this time point. We recommend post-ablation volume assessments be made at least 24 hours post-selective ablation of the amygdalohippocampal complex (SLAH).
Self-powered electrospinning apparatus based on a hand-operated Wimshurst generator
NASA Astrophysics Data System (ADS)
Han, Wen-Peng; Huang, Yuan-Yuan; Yu, Miao; Zhang, Jun-Cheng; Yan, Xu; Yu, Gui-Feng; Zhang, Hong-Di; Yan, Shi-Ying; Long, Yun-Ze
2015-03-01
A conventional electrospinning setup cannot work without a plug (electricity supply). In this article, we report a self-powered electrospinning setup based on a hand-operated Wimshurst generator. The new device has better applicability and portability than a typical conventional electrospinning setup because it is lightweight and can work without an external power supply. Experimental parameters of the apparatus such as the minimum number of handle turns to generate enough energy to spin, rotation speed of the handle and electrospinning distance were investigated. Different polymers such as polystyrene (PS), poly(vinylidene fluoride) (PVDF), polycaprolactone (PCL) and polylactic acid (PLA) were electrospun into ultrathin fibers successfully by this apparatus. The stability, reliability, and repeatability of the new apparatus demonstrate that it can be used as not only a demonstrator for an electrospinning process, but also a beneficial complement to conventional electrospinning especially where or when without a power supply, and may be used in wound healing and rapid hemostasis, etc.A conventional electrospinning setup cannot work without a plug (electricity supply). In this article, we report a self-powered electrospinning setup based on a hand-operated Wimshurst generator. The new device has better applicability and portability than a typical conventional electrospinning setup because it is lightweight and can work without an external power supply. Experimental parameters of the apparatus such as the minimum number of handle turns to generate enough energy to spin, rotation speed of the handle and electrospinning distance were investigated. Different polymers such as polystyrene (PS), poly(vinylidene fluoride) (PVDF), polycaprolactone (PCL) and polylactic acid (PLA) were electrospun into ultrathin fibers successfully by this apparatus. The stability, reliability, and repeatability of the new apparatus demonstrate that it can be used as not only a demonstrator for an electrospinning process, but also a beneficial complement to conventional electrospinning especially where or when without a power supply, and may be used in wound healing and rapid hemostasis, etc. Electronic supplementary information (ESI) available: The video of the electrospinning process by this new self-powered electrospinning apparatus and the vivid details were recorded by a high-speed digital video camera. See DOI: 10.1039/c5nr00387c
NASA Astrophysics Data System (ADS)
Todd, Paul; Pierson, Duane L.; Allen, Britt; Silverstein, JoAnn
The formation of biofilms by water microorganisms such as Pseudomonas aeruginosa in spacecraft water systems has been a matter of concern for long-duration space flight. Crewed spacecraft plumbing includes internal surfaces made of 316L stainless steel. Experiments were therefore undertaken to compare the ability of P. aeruginosa to grow in suspension, attach to stainless steel and to grow on stainless steel in low gravity on the space shuttle. Four categories of cultures were studied during two space shuttle flights (STS-69 and STS-77). Cultures on the ground were held in static horizontal or vertical cylindrical containers or were tumbled on a clinostat and activated under conditions identical to those for the flown cultures. The containers used on the ground and in flight were BioServe Space Technologies’ Fluid Processing Apparatus (FPA), an open-ended test tube with rubber septa that allows robotic addition of bacteria to culture media to initiate experiments and the addition of fixative to conclude experiments. Planktonic growth was monitored by spectrophotometry, and biofilms were characterized quantitatively by epifluorescence and scanning electron microscopy. In these experiments it was found that: (1) Planktonic growth in flown cultures was more extensive than in static cultures, as seen repeatedly in the history of space microbiology, and closely resembled the growth of tumbled cultures. (2) Conversely, the attachment of cells in flown cultures was as much as 8 times that in tumbled cultures but not significantly different from that in static horizontal and vertical cultures, consistent with the notion that flowing fluid reduces microbial attachment. (3) The final surface coverage in 8 days was the same for flown and static cultures but less by a factor of 15 in tumbled cultures, where coverage declined during the preceding 4 days. It is concluded that cell attachment to 316L stainless steel in the low gravity of orbital space flight is similar to that found in stagnant cultures at 1 x g. Research was supported by NASA contract NAGW-1197 to the University of Colorado.
Digital-Electronic/Optical Apparatus Would Recognize Targets
NASA Technical Reports Server (NTRS)
Scholl, Marija S.
1994-01-01
Proposed automatic target-recognition apparatus consists mostly of digital-electronic/optical cross-correlator that processes infrared images of targets. Infrared images of unknown targets correlated quickly with images of known targets. Apparatus incorporates some features of correlator described in "Prototype Optical Correlator for Robotic Vision System" (NPO-18451), and some of correlator described in "Compact Optical Correlator" (NPO-18473). Useful in robotic system; to recognize and track infrared-emitting, moving objects as variously shaped hot workpieces on conveyor belt.
Method and apparatus for automated assembly
Jones, Rondall E.; Wilson, Randall H.; Calton, Terri L.
1999-01-01
A process and apparatus generates a sequence of steps for assembly or disassembly of a mechanical system. Each step in the sequence is geometrically feasible, i.e., the part motions required are physically possible. Each step in the sequence is also constraint feasible, i.e., the step satisfies user-definable constraints. Constraints allow process and other such limitations, not usually represented in models of the completed mechanical system, to affect the sequence.
Processing materials inside an atmospheric-pressure radiofrequency nonthermal plasma discharge
Selwyn, Gary S.; Henins, Ivars; Park, Jaeyoung; Herrmann, Hans W.
2006-04-11
Apparatus for the processing of materials involving placing a material either placed between an radio-frequency electrode and a ground electrode, or which is itself one of the electrodes. This is done in atmospheric pressure conditions. The apparatus effectively etches or cleans substrates, such as silicon wafers, or provides cleaning of spools and drums, and uses a gas containing an inert gas and a chemically reactive gas.
Automatic temperature adjustment apparatus
Chaplin, James E.
1985-01-01
An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.
Osborn, Michelle L; Homberger, Dominique G
2015-09-01
The combination of large mastoid processes and clavicles is unique to humans, but the biomechanical and evolutionary significance of their special configuration is poorly understood. As part of the newly conceptualized shoulder suspension apparatus, the mastoid processes and clavicles are shaped by forces exerted by the musculo-fascial components of the cleidomastoid and clavotrapezius muscles as they suspend the shoulders from the head. Because both skeletal elements develop during infancy in tandem with the attainment of an upright posture, increased manual dexterity, and the capacity for walking, we hypothesized that the same forces would have shaped them as the shoulder suspension apparatus evolved in ancestral humans in tandem with an upright posture, increased manual dexterity, and bipedality with swinging arms. Because the shoulder suspension apparatus is subjected to asymmetrical forces from handedness, we predicted that its skeletal features would grow asymmetrically. We used this prediction to test our hypothesis in a natural experiment to correlate the size of the skeletal features with the forces exerted on them. We (1) measured biomechanically relevant bony features within the shoulder suspension apparatus in 101 male human specimens (62 of known handedness); and (2) modeled and analyzed the forces within the shoulder suspension apparatus from X-ray CT data. We identified eight right-handed characters and demonstrated the causal relationship between these right-handed characters and the magnitude and direction of forces acting on them. Our data suggest that the presence of the shoulder suspension apparatus in humans was a necessary precondition for human bipedality. © 2015 Wiley Periodicals, Inc.
Smart Sensors: Why and when the origin was and why and where the future will be
NASA Astrophysics Data System (ADS)
Corsi, C.
2013-12-01
Smart Sensors is a technique developed in the 70's when the processing capabilities, based on readout integrated with signal processing, was still far from the complexity needed in advanced IR surveillance and warning systems, because of the enormous amount of noise/unwanted signals emitted by operating scenario especially in military applications. The Smart Sensors technology was kept restricted within a close military environment exploding in applications and performances in the 90's years thanks to the impressive improvements in the integrated signal read-out and processing achieved by CCD-CMOS technologies in FPA. In fact the rapid advances of "very large scale integration" (VLSI) processor technology and mosaic EO detector array technology allowed to develop new generations of Smart Sensors with much improved signal processing by integrating microcomputers and other VLSI signal processors. inside the sensor structure achieving some basic functions of living eyes (dynamic stare, non-uniformity compensation, spatial and temporal filtering). New and future technologies (Nanotechnology, Bio-Organic Electronics, Bio-Computing) are lightning a new generation of Smart Sensors extending the Smartness from the Space-Time Domain to Spectroscopic Functional Multi-Domain Signal Processing. History and future forecasting of Smart Sensors will be reported.
Flexible ultrasonic pipe inspection apparatus
Jenkins, C.F.; Howard, B.D.
1994-01-01
Pipe crawlers, pipe inspection {open_quotes}rabbits{close_quotes} and similar vehicles are widely used for inspecting the interior surfaces of piping systems, storage tanks and process vessels for damaged or flawed structural features. This paper describes the design of a flexible, modular ultrasonic pipe inspection apparatus.
Apparatus and method for microwave processing of materials
Johnson, A.C.; Lauf, R.J.; Bible, D.W.; Markunas, R.J.
1996-05-28
Disclosed is a variable frequency microwave heating apparatus designed to allow modulation of the frequency of the microwaves introduced into a furnace cavity for testing or other selected applications. The variable frequency heating apparatus is used in the method of the present invention to monitor the resonant processing frequency within the furnace cavity depending upon the material, including the state thereof, from which the workpiece is fabricated. The variable frequency microwave heating apparatus includes a microwave signal generator and a high-power microwave amplifier or a microwave voltage-controlled oscillator. A power supply is provided for operation of the high-power microwave oscillator or microwave amplifier. A directional coupler is provided for detecting the direction and amplitude of signals incident upon and reflected from the microwave cavity. A first power meter is provided for measuring the power delivered to the microwave furnace. A second power meter detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load. 10 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, K.M.; Manson, J.A.E.; Seferis, J.C.
Consolidation of thermoplastic prepregs was measured with an integrally-heated parallel platen apparatus attached to a servo-hydraulic mechanical testing machine. The apparatus was designed as a small-scale, well-instrumented press. The lamination or consolidation process was viewed as a superposition of three distinctly occurring events identified as void volume reduction, fiber spreading, and autohesion. Consolidation was measured in relation to the original prepreg thickness and was reported as compressive or consolidation strain as a function of temperature. The derivative of the consolidation strain, the consolidation strain rate, was found to be qualitatively descriptive of viscoelastic phenomena occurring in the prepreg stack duringmore » consolidation. The apparatus was sensitive enough to identify glass and melt transitions of the polymer matrix, and to provide a measure of the net consolidation for a given processing cycle. The strain and the strain rate data were compared to thermoanalytical prepreg data obtained by Differential Scanning Calorimetry, and Dynamic Mechanical Analysis. Three different thermoplastic matrix composite systems were examined with this apparatus: Poly (etheretherketone), Poly(etherimide), and Poly(ethylene terephthalate). 21 refs.« less
Method and apparatus for processing algae
Chew, Geoffrey; Reich, Alton J.; Dykes, Jr., H. Waite; Di Salvo, Roberto
2012-07-03
Methods and apparatus for processing algae are described in which a hydrophilic ionic liquid is used to lyse algae cells. The lysate separates into at least two layers including a lipid-containing hydrophobic layer and an ionic liquid-containing hydrophilic layer. A salt or salt solution may be used to remove water from the ionic liquid-containing layer before the ionic liquid is reused. The used salt may also be dried and/or concentrated and reused. The method can operate at relatively low lysis, processing, and recycling temperatures, which minimizes the environmental impact of algae processing while providing reusable biofuels and other useful products.
Municipal waste processing apparatus
Mayberry, J.L.
1988-04-13
This invention relates to apparatus for processing municipal waste, and more particularly to vibrating mesh screen conveyor systems for removing grit, glass, and other noncombustible materials from dry municipal waste. Municipal waste must be properly processed and disposed of so that it does not create health risks to the community. Generally, municipal waste, which may be collected in garbage trucks, dumpsters, or the like, is deposited in processing areas such as landfills. Land and environmental controls imposed on landfill operators by governmental bodies have increased in recent years, however, making landfill disposal of solid waste materials more expensive. 6 figs.
Grek, Boris; Bartolick, Joseph; Kennedy, Alan D.
2000-01-01
A method and apparatus for measuring microstructures, anistropy and birefringence in polymers using laser scattered light includes a laser which provides a beam that can be conditioned and is directed at a fiber or film which causes the beam to scatter. Backscatter light is received and processed with detectors and beam splitters to obtain data. The data is directed to a computer where it is processed to obtain information about the fiber or film, such as the birefringence and diameter. This information provides a basis for modifications to the production process to enhance the process.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-19
... application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to... total installed capacity of 32,000 kilowatts, (2) a proposed 4,500-foot-long, 230-kilovolt transmission...: yo' Way, Salamanca, NY 14779; phone (716) 945-1790. FERC Contact: Timothy Looney; phone: (202) 502...
Fast Uncooled Low Density FPA of VPD PbSe for Applications in Hyperspectral Imagery
2009-10-01
Marañosa (ITM-CIDA). Area de Optronica y Acustica Unidad de Sensores y Micro-Nano Tecnologia Arturo Soria, 289 E-28033 Madrid, Spain ABSTRACT...ADDRESS(ES) Instituto Tecnologico de la Marañosa (ITM-CIDA). Area de Optronica y Acustica Unidad de Sensores y Micro-Nano Tecnologia Arturo Soria, 289
77 FR 16215 - Commission Information Collection Activities (FERC-716); Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
...: Title: FERC-716, Good Faith Request for Transmission Service and Response by Transmitting Utility Under... valid good faith request for transmission has been made under section 211 of the FPA. By developing the.... As a result, 18 CFR 2.20 identifies 12 components of a good faith estimate and 5 components of a...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-25
... application for a successive preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to study the feasibility of the Homeowner Tidal Power Electric Generation Project to be located in.... The proposed project would consist of: (1) 10 hydrokinetic turbine units with an estimated total...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-13
... Storage Water Supply LCC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting... Act (FPA), proposing to study the feasibility of the East Maui Pumped Storage Water Supply Project to.... Bart M. O'Keeffe, East Maui Pumped Storage Water Supply LLC; P.O. Box 1916; Discovery Bay, CA 94505...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-20
... facility is constructed, operated, or maintained Y for the generation of electric power and uses for such... Statutory provision Description (Y/N) FPA 30(a)(3)(A), as amended by HREA....... The conduit the facility uses is a tunnel, canal, Y pipeline, aqueduct, flume, ditch, or similar manmade water conveyance that...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-18
... The facility is Y HREA. constructed, operated, or maintained for the generation of electric power and... Conduit Hydropower Facility Satisfies Statutory provision Description (Y/N) FPA 30(a)(3)(A), as amended by The conduit the facility Y HREA. uses is a tunnel, canal, pipeline, aqueduct, flume, ditch, or similar...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-09
...), as amended by HREA.... The facility is constructed, operated, or maintained Y for the generation of... Conduit Hydropower Facility Satisfies Statutory provision Description (Y/N) FPA 30(a)(3)(A), as amended by HREA....... The conduit the facility uses is a tunnel, canal, Y pipeline, aqueduct, flume, ditch, or...
76 FR 10492 - Credit Reforms in Organized Wholesale Electric Markets
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-25
... unsecured credit for all participants, particularly load-serving entities. \\17\\ Order No. 741, FERC Stats... responsibilities, under section 217(b)(4) of the Federal Power Act (FPA) \\19\\ and Order No. 681,\\20\\ to enable load... TDUs argue that they be allowed to request exemptions under Order No. 741 to ensure that a load-serving...
Optical Correction Of Space-Based Telescopes Using A Deformable Mirror System
2016-12-01
FPA). A fast 5 steering mirror is used to move the FOV within the FOR so that the spacecraft does not need to physically move to a new target as...technology review and development roadmap,” Astro2010: The Astronomy and Astrophysics Decadal Survey, 2009, vol. 2010, p. 23. [8] D. Baiocchi, “Design and
The Development and Evaluation of a Parent Empowerment Program for Family Peer Advocates
ERIC Educational Resources Information Center
Rodriguez, James; Olin, S. S.; Hoagwood, Kimberly E.; Shen, Sa; Burton, Geraldine; Radigan, Marleen; Jensen, Peter S.
2011-01-01
Family-to-family services are emerging as an important adjunctive service to traditional mental health care and a vehicle for improving parent engagement and service use in children's mental health services. In New York State, a growing workforce of Family Peer Advocates (FPA) is delivering family-to-family services. We describe the development…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-17
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-83-000] Midcontinent Independent System Operator, Inc.; Notice of Initiation of Proceeding and Refund Effective Date On September 9... date in Docket No. EL13-83-000, established pursuant to section 206(b) of the FPA, will be the date of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-31
... Hydro LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On November 16, 2012, Las Vegas Wash Hydro LLC, filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-26
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-103-000] J.P. Morgan... statements by J.P. Morgan Ventures Energy Corporation constitute violations of section 35.41(b) of the Commission's regulations under the Federal Power Act (FPA).\\1\\ J.P. Morgan Ventures Energy Corporation, 140...
Dual band QWIP focal plane array
NASA Technical Reports Server (NTRS)
Gunapala, Sarath D. (Inventor); Choi, Kwong Kit (Inventor); Bandara, Sumith V. (Inventor)
2005-01-01
A quantum well infrared photodetector (QWIP) that provides two-color image sensing. Two different quantum wells are configured to absorb two different wavelengths. The QWIPs are arrayed in a focal plane array (FPA). The two-color QWIPs are selected for readout by selective electrical contact with the two different QWIPs or by the use of two different wavelength sensitive gratings.
75 FR 33610 - Application To Export Electric Energy; H.Q. Energy Services (U.S.) Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-14
... DEPARTMENT OF ENERGY [OE Docket No. EA-182-C] Application To Export Electric Energy; H.Q. Energy... electric energy from the United States to Canada pursuant to section 202(e) of the Federal Power Act (FPA... transmit electric energy from the United States to Canada as a power marketer using existing international...
77 FR 23238 - Application To Export Electric Energy; Citigroup Energy Canada ULC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-18
... wholesale market in interstate commerce or have a power supply system of its own on which its exports of... U.S. electric power supply system. Copies of this application will be made available, upon request... electric energy from the United States to Canada pursuant to section 202(e) of the Federal Power Act (FPA...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-16
... (FPA), proposing to study the feasibility of the Tuttle Creek Hydroelectric Project (Tuttle Creek Project or project) to be located at the U.S. Army Corps of Engineers' (Corps) Tuttle Creek Dam, on Big Blue River, near Manhattan, Riley County, Kansas. The sole purpose of a preliminary permit, if issued...
Code of Federal Regulations, 2011 CFR
2011-04-01
... section 212 of the FPA, access to the electric transmission system for the purposes of wholesale... on its transmission system. (5) The names of any other parties likely to provide transmission service... requirement by specifying a rate methodology (e.g., embedded or incremental cost) or by referencing an...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-06
... Power Act (FPA), proposing to study the feasibility of the Coffin Butte Pumped Storage Water Power... triangular earth and roller compacted concrete embankment; creating a 50-acre upper reservoir with a storage...); (2) a 6,300-foot-long, 60-foot-high oval earth and roller compacted concrete embankment; creating a...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-31
... Machinery Co., Inc.; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On August 15, 2011, Windsor Machinery Co., Inc. filed an application for a preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to...
77 FR 74472 - Application to Export Electric Energy; Energia Renovable S.C., LLC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-14
... Renovable S.C., LLC AGENCY: Office of Electricity Delivery and Energy Reliability, DOE. ACTION: Notice of application. SUMMARY: Energia Renovable S.C., LLC (Energia Renovable) has applied for authority to transmit....C. 7151(b), 7172(f)) and require authorization under section 202(e) of the FPA (16 U.S.C.824a(e...
77 FR 34378 - PJM Interconnection, L.L.C.; Notice of Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-11
... Interconnection, L.L.C.; Notice of Complaint Take notice that on June 1, 2012, pursuant to section 206 of the Federal Power Act (FPA), 16 U.S.C. 824(e), PJM Interconnection, L.L.C. (PJM) filed proposed revisions to the Amended and Restated Operating Agreement of PJM Interconnection L.L.C. (Operating Agreement) to...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
...), filed an application for a successive preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA), proposing to study the feasibility of the Muskeget Channel Tidal Energy Project to be..., and one experimental turbine unit that would be used to test various open- bladed and helical tidal...
Electromagnetic microforging apparatus for low-cost fabrication of molds for microlens arrays
NASA Astrophysics Data System (ADS)
Pribošek, Jaka; Diaci, Janez
2015-06-01
This study addresses the problem of low-cost microlens fabrication and outlines the development of a novel microforging apparatus for microlens mold fabrication. The apparatus consists of an electromagnetic impact tool which strikes a piston with a hardened steel ball into a workpiece. The impact creates a spherical indentation which serves as a lens cavity. The microforging apparatus is controlled by a microprocessor control unit communicating with a personal computer and enables on-the-fly variation of electromagnetic excitation to control the microforging process. We studied the effects of process parameters on the diameter of the fabricated lens cavities inspected by a custom automatic image processing algorithm. Different microforging regimes are analyzed and discussed. The surface quality of fabricated cavities has been inspected by confocal microscopy and the influence of fill factor on sphericity error has been studied. The proposed microforging method enables the fabrication of molds with 100% fill factor, surface roughness as low as Ra 0.15 µm and sphericity error lower than 0.5 µm. The fabricated microlens arrays exhibit nearly diffraction-limited performance, offering a wide range of possible applications. We believe this study provides access to microoptical technology for smaller optical and computer vision laboratories.
Commerce Laboratory: Mission analysis payload integration study
NASA Technical Reports Server (NTRS)
Bannister, T. C.
1984-01-01
A mission model which will accommodate commercial users and provide a basic data base for further mission planning is reported. The data bases to be developed are: (1) user requirements; (2) apparatus capabilities and availabilities; and (3) carrier capabilities. These data bases are synthesized in a trades and analysis phase along with the STS flight apparatus, and optimum missions will be identified. The completed work is reported. The user requirements data base was expanded to identify within the six scientific disciplines the areas of investigation, investigation categories and status, potential commercial application, interested parties, process, and experiment requirements. The scope of the apparatus data base was expanded to indicate apparatus status as to whether it is ground or flight equipment and, within both categories, whether the apparatus is: (1) existing, (2) under development, (3) planned, or (4) needed. Applications for the apparatus are listed. The methodology is revised in the areas of trades and analysis and mission planning. The carrier capabilities data base was updated and completed.
Method and apparatus of prefetching streams of varying prefetch depth
Gara, Alan [Mount Kisco, NY; Ohmacht, Martin [Yorktown Heights, NY; Salapura, Valentina [Chappaqua, NY; Sugavanam, Krishnan [Mahopac, NY; Hoenicke, Dirk [Seebruck-Seeon, DE
2012-01-24
Method and apparatus of prefetching streams of varying prefetch depth dynamically changes the depth of prefetching so that the number of multiple streams as well as the hit rate of a single stream are optimized. The method and apparatus in one aspect monitor a plurality of load requests from a processing unit for data in a prefetch buffer, determine an access pattern associated with the plurality of load requests and adjust a prefetch depth according to the access pattern.
Electrowinning apparatus and process
Buschmann, Wayne E [Boulder, CO
2012-06-19
Apparatus and processes are disclosed for electrowinning metal from a fluid stream. A representative apparatus comprises at least one spouted bed reactor wherein each said reactor includes an anolyte chamber comprising an anode and configured for containing an anolyte, a catholyte chamber comprising a current collector and configured for containing a particulate cathode bed and a flowing stream of an electrically conductive metal-containing fluid, and a membrane separating said anolyte chamber and said catholyte chamber, an inlet for an electrically conductive metal-containing fluid stream; and a particle bed churning device configured for spouting particle bed particles in the catholyte chamber independently of the flow of said metal-containing fluid stream. In operation, reduced heavy metals or their oxides are recovered from the cathode particles.
Method and apparatus for thermal processing of semiconductor substrates
Griffiths, Stewart K.; Nilson, Robert H.; Mattson, Brad S.; Savas, Stephen E.
2002-01-01
An improved apparatus and method for thermal processing of semiconductor wafers. The apparatus and method provide the temperature stability and uniformity of a conventional batch furnace as well as the processing speed and reduced time-at-temperature of a lamp-heated rapid thermal processor (RTP). Individual wafers are rapidly inserted into and withdrawn from a furnace cavity held at a nearly constant and isothermal temperature. The speeds of insertion and withdrawal are sufficiently large to limit thermal stresses and thereby reduce or prevent plastic deformation of the wafer as it enters and leaves the furnace. By processing the semiconductor wafer in a substantially isothermal cavity, the wafer temperature and spatial uniformity of the wafer temperature can be ensured by measuring and controlling only temperatures of the cavity walls. Further, peak power requirements are very small compared to lamp-heated RTPs because the cavity temperature is not cycled and the thermal mass of the cavity is relatively large. Increased speeds of insertion and/or removal may also be used with non-isothermal furnaces.
Method and apparatus for thermal processing of semiconductor substrates
Griffiths, Stewart K.; Nilson, Robert H.; Mattson, Brad S.; Savas, Stephen E.
2000-01-01
An improved apparatus and method for thermal processing of semiconductor wafers. The apparatus and method provide the temperature stability and uniformity of a conventional batch furnace as well as the processing speed and reduced time-at-temperature of a lamp-heated rapid thermal processor (RTP). Individual wafers are rapidly inserted into and withdrawn from a furnace cavity held at a nearly constant and isothermal temperature. The speeds of insertion and withdrawal are sufficiently large to limit thermal stresses and thereby reduce or prevent plastic deformation of the wafer as it enters and leaves the furnace. By processing the semiconductor wafer in a substantially isothermal cavity, the wafer temperature and spatial uniformity of the wafer temperature can be ensured by measuring and controlling only temperatures of the cavity walls. Further, peak power requirements are very small compared to lamp-heated RTPs because the cavity temperature is not cycled and the thermal mass of the cavity is relatively large. Increased speeds of insertion and/or removal may also be used with non-isothermal furnaces.
Method and Apparatus for Processing UDP Data Packets
NASA Technical Reports Server (NTRS)
Murphy, Brandon M. (Inventor)
2017-01-01
A method and apparatus for processing a plurality of data packets. A data packet is received. A determination is made as to whether a portion of the data packet follows a selected digital recorder standard protocol based on a header of the data packet. Raw data in the data packet is converted into human-readable information in response to a determination that the portion of the data packet follows the selected digital recorder standard protocol.
Pyrolysis process and apparatus
Lee, Chang-Kuei
1983-01-01
This invention discloses a process and apparatus for pyrolyzing particulate coal by heating with a particulate solid heating media in a transport reactor. The invention tends to dampen fluctuations in the flow of heating media upstream of the pyrolysis zone, and by so doing forms a substantially continuous and substantially uniform annular column of heating media flowing downwardly along the inside diameter of the reactor. The invention is particularly useful for bituminous or agglomerative type coals.
Semiautomated, Reproducible Batch Processing of Soy
NASA Technical Reports Server (NTRS)
Thoerne, Mary; Byford, Ivan W.; Chastain, Jack W.; Swango, Beverly E.
2005-01-01
A computer-controlled apparatus processes batches of soybeans into one or more of a variety of food products, under conditions that can be chosen by the user and reproduced from batch to batch. Examples of products include soy milk, tofu, okara (an insoluble protein and fiber byproduct of soy milk), and whey. Most processing steps take place without intervention by the user. This apparatus was developed for use in research on processing of soy. It is also a prototype of other soy-processing apparatuses for research, industrial, and home use. Prior soy-processing equipment includes household devices that automatically produce soy milk but do not automatically produce tofu. The designs of prior soy-processing equipment require users to manually transfer intermediate solid soy products and to press them manually and, hence, under conditions that are not consistent from batch to batch. Prior designs do not afford choices of processing conditions: Users cannot use previously developed soy-processing equipment to investigate the effects of variations of techniques used to produce soy milk (e.g., cold grinding, hot grinding, and pre-cook blanching) and of such process parameters as cooking times and temperatures, grinding times, soaking times and temperatures, rinsing conditions, and sizes of particles generated by grinding. In contrast, the present apparatus is amenable to such investigations. The apparatus (see figure) includes a processing tank and a jacketed holding or coagulation tank. The processing tank can be capped by either of two different heads and can contain either of two different insertable mesh baskets. The first head includes a grinding blade and heating elements. The second head includes an automated press piston. One mesh basket, designated the okara basket, has oblong holes with a size equivalent to about 40 mesh [40 openings per inch (.16 openings per centimeter)]. The second mesh basket, designated the tofu basket, has holes of 70 mesh [70 openings per inch (.28 openings per centimeter)] and is used in conjunction with the press-piston head. Supporting equipment includes a soy-milk heat exchanger for maintaining selected coagulation temperatures, a filter system for separating okara from other particulate matter and from soy milk, two pumps, and various thermocouples, flowmeters, level indicators, pressure sensors, valves, tubes, and sample ports
Fiber-optic strain gauge with attached ends and unattached microbend section
Weiss, J.D.
1992-07-21
A strain gauge is made of an optical fiber into which quasi-sinusoidal microbends have been permanently introduced. The permanent microbends cause a reduction in the fiber's optical transmission, but, when the gauge is attached to a substrate that is subsequently strained, the amplitude of the deformations will diminish and the optical transmission through the fiber will increase. An apparatus and process for manufacturing these microbends into the optical fiber through a heat-set process is employed; this apparatus and process includes a testing and calibration system. 5 figs.
MIRIADS: miniature infrared imaging applications development system description and operation
NASA Astrophysics Data System (ADS)
Baxter, Christopher R.; Massie, Mark A.; McCarley, Paul L.; Couture, Michael E.
2001-10-01
A cooperative effort between the U.S. Air Force Research Laboratory, Nova Research, Inc., the Raytheon Infrared Operations (RIO) and Optics 1, Inc. has successfully produced a miniature infrared camera system that offers significant real-time signal and image processing capabilities by virtue of its modular design. This paper will present an operational overview of the system as well as results from initial testing of the 'Modular Infrared Imaging Applications Development System' (MIRIADS) configured as a missile early-warning detection system. The MIRIADS device can operate virtually any infrared focal plane array (FPA) that currently exists. Programmable on-board logic applies user-defined processing functions to the real-time digital image data for a variety of functions. Daughterboards may be plugged onto the system to expand the digital and analog processing capabilities of the system. A unique full hemispherical infrared fisheye optical system designed and produced by Optics 1, Inc. is utilized by the MIRIADS in a missile warning application to demonstrate the flexibility of the overall system to be applied to a variety of current and future AFRL missions.
Systems, methods, and apparatus of a low conductance silicon micro-leak for mass spectrometer inlet
NASA Technical Reports Server (NTRS)
Harpold, Dan N. (Inventor); Niemann, Hasso B. (Inventor); Jamieson, Brian G. (Inventor); Lynch, Bernard A. (Inventor)
2011-01-01
Systems, methods and apparatus are provided through which in some embodiments a mass spectrometer micro-leak includes a number of channels fabricated by semiconductor processing tools and that includes a number of inlet holes that provide access to the channels.
Systems, Methods, and Apparatus of a Low Conductance Silicon Micro-Leak for Mass Spectrometer Inlet
NASA Technical Reports Server (NTRS)
Harpold, Dan N. (Inventor); Niemann, Hasso B. (Inventor); Jamieson, Brian G. (Inventor); Lynch, Bernard A. (Inventor)
2013-01-01
Systems, methods and apparatus are provided through which in some embodiments a mass spectrometer micro-leak includes a number of channels fabricated by semiconductor processing tools and that includes a number of inlet holes that provide access to the channels.
Chang, Tzyy-Shuh; Huang, Hsun-Hau; Lin, Chang-Hung
2007-10-02
An adjustable guide, includes two or more mechanisms each having a rotatable retaining element containing a retaining groove with a variable radius in its perimeter surface. The grooves form a guidance path to control the lateral, i.e. non-axial, motion of a long bar moving along a longitudinal axis during a production process.The diameter of the guidance path varies according to the variable radii of the grooves. The guidance path increases in size at a predetermined rate, from a point of origin to an end point on the retaining groove. Rotating the retaining elements causes the diameter of the retaining grooves to change so that the size of the guidance path can be changed to match the diameter of the bar being rolled, size of the guidance path can be changed to fit the diameter of a new bar rolled without having to exchange the guide for a different sized guide, reduce fiction between the bar and the guide, a media, such as compressed air, can be injected between the retaining elements via orifices.Each retaining element is attached to a mounting apparatus. The mounting apparatus can be fixed or flexible. The flexible mounting apparatus includes one or more springs and one or more shock absorbers. A force neutral position of the flexible mounting apparatus is designed to be located on the predetermined ideal bar path line. The flexible mounting apparatus dissipates kinetic energy from the bar thereby reducing the bar's lateral motion relative to the ideal bar path line.The damping ratio of the mounting apparatus can be adjustable to alter the product's vibration mode to enable better control of the bar's lateral motion.
Miller, W.E.
1988-06-07
An apparatus for removing dendrites or other crystalline matter from the surface of a liquid in a matter transport process, and an electrolytic cell including such an apparatus. A notch may be provided to allow continuous exposure of the liquid surface, and a bore may be further provided to permit access to the liquid. 2 figs.
Use of steel and tantalum apparatus for molten Cd-Mg-Zn alloys
NASA Technical Reports Server (NTRS)
Bennett, G. A.; Burris, L., Jr.; Kyle, M. L.; Nelson, P. A.
1966-01-01
Steel and tantalum apparatus contains various ternary alloys of cadmium, zinc, and magnesium used in pyrochemical processes for the recovery of uranium-base reactor fuels. These materials exhibit good corrosion resistance at the high temperatures necessary for fuel separation in liquid metal-molten salt solvents.
Miller, William E.
1989-01-01
An apparatus for removing dendrites or other crystalline matter from the surface of a liquid in a matter transport process, and an electrolytic cell including such an apparatus. A notch may be provided to allow continuous exposure of the liquid surface, and a bore may be further provided to permit access to the liquid.
APPARATUS FOR SHORT TIME MEASUREMENTS IN A FIXED-BED, GAS/SOLID REACTOR
An apparatus for exposure of a solid to reactive process gas is described which makes possible short time (≥ 0.3 to 15 s) exposures in a fixed-bed reactor. Operating conditions for differential reaction with respect to the gas concentration and rapid quench for arresting hi...
USSR and Eastern Europe Scientific Abstracts, Geophysics, Astronomy and Space, Number 426
1978-08-01
Report on "Soyuz-30" Docking.., 22 Comments on " Sirena " Experiment Aboard "Salyut-6" 24 Vereshchetin Comments on Polish Contribution to...began the joint Polish-Soviet materials processing experiment " Sirena " in the "Splav" apparatus. They were also engaged in physical exercise...34 Sirena " materials processing experiment was continued as the cosmonauts monitored the operation of the "Splav" apparatus and the temperature regime of
Continuous microwave regeneration apparatus for absorption media
Smith, Douglas D.
1999-01-01
A method and apparatus for continuously drying and regenerating ceramic beads for use in process gas moisture drying operations such as glove boxes. A microwave energy source is coupled to a process chamber to internally heat the ceramic beads and vaporize moisture contained therein. In a preferred embodiment, the moisture laden ceramic beads are conveyed toward the microwave source by a screw mechanism. The regenerated beads flow down outside of the screw mechanism and are available to absorb additional moisture.
Crystal growth and annealing method and apparatus
Gianoulakis, Steven E.; Sparrow, Robert
2001-01-01
A method and apparatus for producing crystals that minimizes birefringence even at large crystal sizes, and is suitable for production of CaF.sub.2 crystals. The method of the present invention comprises annealing a crystal by maintaining a minimal temperature gradient in the crystal while slowly reducing the bulk temperature of the crystal. An apparatus according to the present invention includes a thermal control system added to a crystal growth and annealing apparatus, wherein the thermal control system allows a temperature gradient during crystal growth but minimizes the temperature gradient during crystal annealing. An embodiment of the present invention comprises a secondary heater incorporated into a conventional crystal growth and annealing apparatus. The secondary heater supplies heat to minimize the temperature gradients in the crystal during the annealing process. The secondary heater can mount near the bottom of the crucible to effectively maintain appropriate temperature gradients.
75 FR 16449 - Central Transmission, LLC v. PJM Interconnection L.L.C.; Notice of Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-01
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL10-52-000] Central Transmission, LLC v. PJM Interconnection L.L.C.; Notice of Complaint March 26, 2010. Take notice that on March... Interconnection L.L.C. (PJM) pursuant to section 206 of the Federal Power Act (FPA), alleging that Schedule 6 of...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... Cable, LLC; Notice of Institution of Section 206 Investigation and Refund Effective Date July 30, 2010...-116-000, pursuant to section 206 of the Federal Power Act (FPA), 16 U.S.C. 824e, concerning the justness and reasonableness of rates proposed by Trans Bay Cable, LLC (Trans Bay) in [[Page 47589
Cetacean Social Behavioral Response to Sonar Exposure
2015-09-30
Lam FPA, Tyack PLT, Miller PJO (in review). Disturbance-specific social responses in long-finned pilot whales, Globicephala melas . Fieldwork...the social behavioral response of long-finned pilot whales (Globicephala melas ) revealed that a unifying characteristic of their behavioral response...Globicephala melas . 6 Visser F. et al. (in review). Vocal foragers and silent crowds: the socio-behavioural context of long- finned pilot whale
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-09
... maintained for the Y amended by HREA. generation of electric power and uses for such generation only the... Statutory provision Description (Y/N) FPA 30(a)(3)(A), as amended The conduit the facility uses is a tunnel, canal, pipeline, Y by HREA. aqueduct, flume, ditch, or similar manmade water conveyance that is operated...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
... maintained for Y HREA. the generation of electric power and uses for such generation only the hydroelectric... provision Description (Y/N) FPA 30(a)(3)(A), as amended by HREA.. The conduit the facility uses is a tunnel, canal, pipeline, Y aqueduct, flume, ditch, or similar manmade water conveyance that is operated for the...
LaWen Hollingsworth; James Menakis
2010-01-01
This project mapped wildland fire potential (WFP) for the conterminous United States by using the large fire simulation system developed for Fire Program Analysis (FPA) System. The large fire simulation system, referred to here as LFSim, consists of modules for weather generation, fire occurrence, fire suppression, and fire growth modeling. Weather was generated with...
78 FR 70035 - Idaho Power Company; Notice of Initiation of Proceeding and Refund Effective Date
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-22
... Company; Notice of Initiation of Proceeding and Refund Effective Date On November 13, 2013, the Commission...-based rates proposed by Idaho Power Company. Idaho Power Company, 145 FERC ] 61,122 (2013). The refund effective date in Docket No. EL14-3-000, established pursuant to section 206(b) of the FPA, will be the date...
78 FR 69411 - Idaho Power Company; Notice of Initiation of Proceeding and Refund Effective Date
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-19
... Company; Notice of Initiation of Proceeding and Refund Effective Date On November 13, 2013, the Commission...-based rates proposed by Idaho Power Company. Idaho Power Company, 145 FERC ] 61,122 (2013). The refund effective date in Docket No. EL14-3-000, established pursuant to section 206(b) of the FPA, will be the date...
The Impact of Emerging Technologies on Future Air Capabilities
1999-12-01
ferroelectric FPAs (60). More advanced FPA technologies include quantum well IR photodetectors ( QWIPS ) and strained layer superlattices. Significant...microspacecraft. Expected benefits include enhanced handling qualities, vibration suppression, alleviation of noise and vibration and monitoring of vehicle...of fatigue loads, cabin vibration and both internal and external noise , as well as contributing to enhanced handling. This would result in better
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... California; and (14) appurtenant facilities. The project would be a closed-loop system using groundwater and... application for a successive preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA... power tunnel; (6) a 30-foot-diameter, 1,200-foot-long vertical shaft; (7) a 30-foot-diameter, 1,000-foot...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-27
... to section 4(f) of the Federal Power Act (FPA), proposing to study the feasibility of the East Foreland Tidal Energy Project (East Foreland project) to be located in Cook Inlet in the vicinity of... from the module site to a shore station on the west coast of the Kenai Peninsula; (3) an approximately...
Method and apparatus for real time weld monitoring
Leong, Keng H.; Hunter, Boyd V.
1997-01-01
An improved method and apparatus are provided for real time weld monitoring. An infrared signature emitted by a hot weld surface during welding is detected and this signature is compared with an infrared signature emitted by the weld surface during steady state conditions. The result is correlated with weld penetration. The signal processing is simpler than for either UV or acoustic techniques. Changes in the weld process, such as changes in the transmitted laser beam power, quality or positioning of the laser beam, change the resulting weld surface features and temperature of the weld surface, thereby resulting in a change in the direction and amount of infrared emissions. This change in emissions is monitored by an IR sensitive detecting apparatus that is sensitive to the appropriate wavelength region for the hot weld surface.
Method and apparatus for ion sequestration and a nanostructured metal phosphate
Mattigod, Shas V [Richland, WA; Fryxell, Glen E [Kennewic, WA; Li, Xiaohong [Richland, WA; Parker, Kent E [Kennewick, WA; Wellman, Dawn M [West Richland, WA
2010-04-06
A nanostructured substance, a process for sequestration of ionic waste, and an ion-sequestration apparatus are disclosed in the specification. The nanostructured substance can comprise a Lewis acid transition metal bound to a phosphate, wherein the phosphate comprises a primary structural component of the substance and the Lewis acid transition metal is a reducing agent. The nanostructured substance has a Brunner-Emmet-Teller (BET) surface area greater than or equal to approximately 100 m.sup.2/g, and a distribution coefficient for an analyte, K.sub.d, greater than or equal to approximately 5000 ml/g. The process can comprise contacting a fluid and a nanostructured metal phosphate. The apparatus can comprise a vessel and a nanostructured metal phosphate. The vessel defines a volume wherein a fluid contacts the nanostructured metal phosphate.
Liu, Yun-Tao; Luo, Ze-Yu; Long, Chuan-Nan; Wang, Hai-Dong; Long, Min-Nan; Hu, Zhong
2011-10-01
To produce cellulolytic enzyme efficiently, Penicillium decumbens strain L-06 was used to prepare mutants with ethyl methane sulfonate (EMS) and UV-irradiation. A mutant strain ML-017 is shown to have a higher cellulase activity than others. Box-Behnken's design (BBD) and response surface methodology (RSM) were adopted to optimize the conditions of cellulase (filter paper activity, FPA) production in strain ML-017 by solid-state fermentation (SSF) with rice bran as the substrate. And the result shows that the initial pH, moisture content and culture temperature all have significant effect on the production of cellulase. The optimized condition shall be initial pH 5.7, moisture content 72% and culture temperature 30°C. The maximum cellulase (FPA) production was obtained under the optimized condition, which is 5.76 IU g(-1), increased by 44.12% to its original strain. It corresponded well with the calculated results (5.15 IU g(-1)) by model prediction. The result shows that both BBD and RSM are the cellulase optimization methods with good prospects. Copyright © 2011 Elsevier B.V. All rights reserved.
ATTICA family of thermal cameras in submarine applications
NASA Astrophysics Data System (ADS)
Kuerbitz, Gunther; Fritze, Joerg; Hoefft, Jens-Rainer; Ruf, Berthold
2001-10-01
Optronics Mast Systems (US: Photonics Mast Systems) are electro-optical devices which enable a submarine crew to observe the scenery above water during dive. Unlike classical submarine periscopes they are non-hull-penetrating and therefore have no direct viewing capability. Typically they have electro-optical cameras both for the visual and for an IR spectral band with panoramic view and a stabilized line of sight. They can optionally be equipped with laser range- finders, antennas, etc. The brand name ATTICA (Advanced Two- dimensional Thermal Imager with CMOS-Array) characterizes a family of thermal cameras using focal-plane-array (FPA) detectors which can be tailored to a variety of requirements. The modular design of the ATTICA components allows the use of various detectors (InSb, CMT 3...5 μm , CMT 7...11 μm ) for specific applications. By means of a microscanner ATTICA cameras achieve full standard TV resolution using detectors with only 288 X 384 (US:240 X 320) detector elements. A typical requirement for Optronics-Mast Systems is a Quick- Look-Around capability. For FPA cameras this implies the need for a 'descan' module which can be incorporated in the ATTICA cameras without complications.
Quantum efficiency investigations of type-II InAs/GaSb midwave infrared superlattice photodetectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giard, E., E-mail: edouard.giard@onera.fr; Ribet-Mohamed, I.; Jaeck, J.
2014-07-28
We present in this paper a comparison between different type-II InAs/GaSb superlattice (T2SL) photodiodes and focal plane array (FPA) in the mid-wavelength infrared domain to understand which phenomenon drives the performances of the T2SL structure in terms of quantum efficiency (QE). Our measurements on test photodiodes suggest low minority carrier diffusion length in the “InAs-rich” design, which penalizes carriers' collection in this structure for low bias voltage and front side illumination. This analysis is completed by a comparison of the experimental data with a fully analytic model, which allows to infer a hole diffusion length shorter than 100 nm. In addition,more » measurements on a FPA with backside illumination are finally presented. Results show an average QE in the 3–4.7 μm window equal to 42% for U{sub bias} = −0.1 V, 77 K operating temperature and no anti-reflection coating. These measurements, completed by modulation transfer function and noise measurements, reveal that the InAs-rich design, despite a low hole diffusion length, is promising for high performance infrared imaging applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vishnyakov, A. V.; Stuchinsky, V. A., E-mail: stuchin@isp.nsc.ru; Brunev, D. V.
2014-03-03
In the present paper, we propose a method for evaluating the bulk diffusion length of minority charge carriers in the photosensing layer of photovoltaic focal plane array (FPA) photodetectors. The method is based on scanning a strip-shaped illumination spot with one of the detector diodes at a low level of photocurrents j{sub ph} being registered; such scanning provides data for subsequent analysis of measured spot-scan profiles within a simple diffusion model. The asymptotic behavior of the effective (at j{sub ph} ≠ 0) charge-carrier diffusion length l{sub d} {sub eff} as a function of j{sub ph} for j{sub ph} → 0 inferred frommore » our experimental data proved to be consistent with the behavior of l{sub d} {sub eff} vs j{sub ph} as predicted by the model, while the obtained values of the bulk diffusion length of minority carriers (electrons) in the p-HgCdTe film of investigated HgCdTe n-on-p FPA photodetectors were found to be in a good agreement with the previously reported carrier diffusion-length values for HgCdTe.« less
NASA Astrophysics Data System (ADS)
Escribano, Rafel; Gonzàlez-Solís, Sergi
2018-01-01
The dilepton invariant mass spectra and integrated branching ratios of the single and double Dalitz decays {\\mathscr{P}}\\to {{{l}}}+{{{l}}}-{{γ }} and {\\mathscr{P}}\\to {{{l}}}+{{{l}}}-{{{l}}}+{{{l}}}- ({\\mathscr{P}}={{{π }}}0,{{η }},{{{η }}}\\prime; {{l}}={{e}} or {{μ }}) are predicted by means of a data-driven approach based on the use of rational approximants applied to {{{π }}}0,{{η }} and {{{η }}}\\prime transition form factor experimental data in the space-like region. Supported by the FPI scholarship BES-2012-055371 (S.G-S), the Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya under grant 2014 SGR 1450, the Ministerio de Ciencia e Innovación under grant FPA2011-25948, the Ministerio de Economía y Competitividad under grants CICYT-FEDER-FPA 2014-55613-P and SEV-2012-0234, the Spanish Consolider-Ingenio 2010 Program CPAN (CSD2007-00042), and the European Commission under program FP7-INFRASTRUCTURES-2011-1 (283286) S.G-S also Received Support from the CAS President’s International Fellowship Initiative for Young International Scientist (2017PM0031)
Lee, Chulsung; Lee, Dustin; Darling, Cynthia L; Fried, Daniel
2010-01-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310 nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study is to determine whether the lesion contrast derived from NIR imaging in both transmission and reflectance can be used to estimate lesion severity. Two NIR imaging detector technologies are investigated: a new Ge-enhanced complementary metal-oxide-semiconductor (CMOS)-based NIR imaging camera, and an InGaAs focal plane array (FPA). Natural occlusal caries lesions are imaged with both cameras at 1310 nm, and the image contrast between sound and carious regions is calculated. After NIR imaging, teeth are sectioned and examined using polarized light microscopy (PLM) and transverse microradiography (TMR) to determine lesion severity. Lesions are then classified into four categories according to lesion severity. Lesion contrast increases significantly with lesion severity for both cameras (p<0.05). The Ge-enhanced CMOS camera equipped with the larger array and smaller pixels yields higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
In vitro near-infrared imaging of occlusal dental caries using a germanium-enhanced CMOS camera
NASA Astrophysics Data System (ADS)
Lee, Chulsung; Darling, Cynthia L.; Fried, Daniel
2010-02-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310-nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study was to determine whether the lesion contrast derived from NIR transillumination can be used to estimate lesion severity. Another aim was to compare the performance of a new Ge enhanced complementary metal-oxide-semiconductor (CMOS) based NIR imaging camera with the InGaAs focal plane array (FPA). Extracted human teeth (n=52) with natural occlusal caries were imaged with both cameras at 1310-nm and the image contrast between sound and carious regions was calculated. After NIR imaging, teeth were sectioned and examined using more established methods, namely polarized light microscopy (PLM) and transverse microradiography (TMR) to calculate lesion severity. Lesions were then classified into 4 categories according to the lesion severity. Lesion contrast increased significantly with lesion severity for both cameras (p<0.05). The Ge enhanced CMOS camera equipped with the larger array and smaller pixels yielded higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
Lee, Chulsung; Lee, Dustin; Darling, Cynthia L.; Fried, Daniel
2010-01-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310 nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study is to determine whether the lesion contrast derived from NIR imaging in both transmission and reflectance can be used to estimate lesion severity. Two NIR imaging detector technologies are investigated: a new Ge-enhanced complementary metal-oxide-semiconductor (CMOS)-based NIR imaging camera, and an InGaAs focal plane array (FPA). Natural occlusal caries lesions are imaged with both cameras at 1310 nm, and the image contrast between sound and carious regions is calculated. After NIR imaging, teeth are sectioned and examined using polarized light microscopy (PLM) and transverse microradiography (TMR) to determine lesion severity. Lesions are then classified into four categories according to lesion severity. Lesion contrast increases significantly with lesion severity for both cameras (p<0.05). The Ge-enhanced CMOS camera equipped with the larger array and smaller pixels yields higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity. PMID:20799842
NASA Astrophysics Data System (ADS)
Lee, Chulsung; Lee, Dustin; Darling, Cynthia L.; Fried, Daniel
2010-07-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310 nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study is to determine whether the lesion contrast derived from NIR imaging in both transmission and reflectance can be used to estimate lesion severity. Two NIR imaging detector technologies are investigated: a new Ge-enhanced complementary metal-oxide-semiconductor (CMOS)-based NIR imaging camera, and an InGaAs focal plane array (FPA). Natural occlusal caries lesions are imaged with both cameras at 1310 nm, and the image contrast between sound and carious regions is calculated. After NIR imaging, teeth are sectioned and examined using polarized light microscopy (PLM) and transverse microradiography (TMR) to determine lesion severity. Lesions are then classified into four categories according to lesion severity. Lesion contrast increases significantly with lesion severity for both cameras (p<0.05). The Ge-enhanced CMOS camera equipped with the larger array and smaller pixels yields higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
In vitro near-infrared imaging of occlusal dental caries using germanium enhanced CMOS camera.
Lee, Chulsung; Darling, Cynthia L; Fried, Daniel
2010-03-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310-nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study was to determine whether the lesion contrast derived from NIR transillumination can be used to estimate lesion severity. Another aim was to compare the performance of a new Ge enhanced complementary metal-oxide-semiconductor (CMOS) based NIR imaging camera with the InGaAs focal plane array (FPA). Extracted human teeth (n=52) with natural occlusal caries were imaged with both cameras at 1310-nm and the image contrast between sound and carious regions was calculated. After NIR imaging, teeth were sectioned and examined using more established methods, namely polarized light microscopy (PLM) and transverse microradiography (TMR) to calculate lesion severity. Lesions were then classified into 4 categories according to the lesion severity. Lesion contrast increased significantly with lesion severity for both cameras (p<0.05). The Ge enhanced CMOS camera equipped with the larger array and smaller pixels yielded higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
NASA Astrophysics Data System (ADS)
Haka, Abigail S.; Kidder, Linda H.; Lewis, E. Neil
2001-07-01
We have applied Fourier transform infrared (FTIR) spectroscopic imaging, coupling a mercury cadmium telluride (MCT) focal plane array detector (FPA) and a Michelson step scan interferometer, to the investigation of various states of malignant human prostate tissue. The MCT FPA used consists of 64x64 pixels, each 61 micrometers 2, and has a spectral range of 2-10.5 microns. Each imaging data set was collected at 16-1 resolution, resulting in 512 image planes and a total of 4096 interferograms. In this article we describe a method for separating different tissue types contained within FTIR spectroscopic imaging data sets of human prostate tissue biopsies. We present images, generated by the Fuzzy C-Means clustering algorithm, which demonstrate the successful partitioning of distinct tissue type domains. Additionally, analysis of differences in the centroid spectra corresponding to different tissue types provides an insight into their biochemical composition. Lastly, we demonstrate the ability to partition tissue type regions in a different data set using centroid spectra calculated from the original data set. This has implications for the use of the Fuzzy C-Means algorithm as an automated technique for the separation and examination of tissue domains in biopsy samples.
ISOLATION AND DETECTION OF GIARDIA CYSTS FROM WATER USING DIRECT IMMUNOFLUORESCENCE.
Sorenson, Stephen K.; Riggs, John L.; Dileanis, Peter D.; Suk, Thomas J.
1986-01-01
A water-sampling apparatus used for the isolation and detection of Giardia cysts in water has been designed and tested. The sampling apparatus uses one of a variety of pumps or waterline pressure to move water through a filter. Two of the optional pumps are lightweight enough to make the apparatus portable and thus suitable for sampling in remote areas. This technique of sample processing produces good cyst recovery in much less time than is required with previously established methods. Giardia cysts are identified using direct immunofluorescence.
Nonlinear structural crack growth monitoring
Welch, Donald E.; Hively, Lee M.; Holdaway, Ray F.
2002-01-01
A method and apparatus are provided for the detection, through nonlinear manipulation of data, of an indicator of imminent failure due to crack growth in structural elements. The method is a process of determining energy consumption due to crack growth and correlating the energy consumption with physical phenomena indicative of a failure event. The apparatus includes sensors for sensing physical data factors, processors or the like for computing a relationship between the physical data factors and phenomena indicative of the failure event, and apparatus for providing notification of the characteristics and extent of such phenomena.
Apparatus and method for the electrolysis of water
Greenbaum, Elias
2015-04-21
An apparatus for the electrolytic splitting of water into hydrogen and/or oxygen, the apparatus comprising: (i) at least one lithographically-patternable substrate having a surface; (ii) a plurality of microscaled catalytic electrodes embedded in said surface; (iii) at least one counter electrode in proximity to but not on said surface; (iv) means for collecting evolved hydrogen and/or oxygen gas; (v) electrical powering means for applying a voltage across said plurality of microscaled catalytic electrodes and said at least one counter electrode; and (vi) a container for holding an aqueous electrolyte and housing said plurality of microscaled catalytic electrodes and said at least one counter electrode. Electrolytic processes using the above electrolytic apparatus or functional mimics thereof are also described.
Combustion process for synthesis of carbon nanomaterials from liquid hydrocarbon
Diener, Michael D.; Alford, J. Michael; Nabity, James; Hitch, Bradley D.
2007-01-02
The present invention provides a combustion apparatus for the production of carbon nanomaterials including fullerenes and fullerenic soot. Most generally the combustion apparatus comprises one or more inlets for introducing an oxygen-containing gas and a hydrocarbon fuel gas in the combustion system such that a flame can be established from the mixed gases, a droplet delivery apparatus for introducing droplets of a liquid hydrocarbon feedstock into the flame, and a collector apparatus for collecting condensable products containing carbon nanomaterials that are generated in the combustion system. The combustion system optionally has a reaction zone downstream of the flame. If this reaction zone is present the hydrocarbon feedstock can be introduced into the flame, the reaction zone or both.
Stretchable polymer-based electronic device
Maghribi, Mariam N [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA; Davidson, James Courtney [Livermore, CA; Wilson, Thomas S [Castro Valley, CA; Hamilton, Julie K [Tracy, CA; Benett, William J [Livermore, CA; Tovar, Armando R [San Antonio, TX
2008-02-26
A stretchable electronic circuit or electronic device and a polymer-based process to produce a circuit or electronic device containing a stretchable conducting circuit. The stretchable electronic apparatus has a central longitudinal axis and the apparatus is stretchable in a longitudinal direction generally aligned with the central longitudinal axis. The apparatus comprises a stretchable polymer body and at least one circuit line operatively connected to the stretchable polymer body. The circuit line extends in the longitudinal direction and has a longitudinal component that extends in the longitudinal direction and has an offset component that is at an angle to the longitudinal direction. The longitudinal component and the offset component allow the apparatus to stretch in the longitudinal direction while maintaining the integrity of the circuit line.
Apparatus and method for ultrasonic treatment of a liquid
Chandler, Darrell P.; Posakony, Gerald J.; Bond, Leonard J.; Bruckner-Lea, Cynthia J.
2006-04-04
The present invention is an apparatus for ultrasonically treating a liquid to generate a product. The apparatus is capable of treating a continuously-flowing, or intermittently-flowing, liquid along a line segment coincident with the flow path of the liquid. The apparatus has one or more ultrasonic transducers positioned asymmetrically about the line segment. The ultrasonic field encompasses the line segment and the ultrasonic energy may be concentrated along the line segment. Lysing treatments have been successfully achieved with efficiencies of greater than 99% using ultrasound at MHz frequencies without erosion or heating problems and without the need for chemical or mechanical pretreatment, or contrast agents. The present invention overcomes drawbacks of current ultrasonic treatments beyond lysing and opens up new sonochemical and sonophysical processing opportunities.
Polarization Imaging Apparatus
NASA Technical Reports Server (NTRS)
Zou, Yingyin K.; Chen, Qiushui
2010-01-01
A polarization imaging apparatus has shown promise as a prototype of instruments for medical imaging with contrast greater than that achievable by use of non-polarized light. The underlying principles of design and operation are derived from observations that light interacts with tissue ultrastructures that affect reflectance, scattering, absorption, and polarization of light. The apparatus utilizes high-speed electro-optical components for generating light properties and acquiring polarization images through aligned polarizers. These components include phase retarders made of OptoCeramic (registered TradeMark) material - a ceramic that has a high electro-optical coefficient. The apparatus includes a computer running a program that implements a novel algorithm for controlling the phase retarders, capturing image data, and computing the Stokes polarization images. Potential applications include imaging of superficial cancers and other skin lesions, early detection of diseased cells, and microscopic analysis of tissues. The high imaging speed of this apparatus could be beneficial for observing live cells or tissues, and could enable rapid identification of moving targets in astronomy and national defense. The apparatus could also be used as an analysis tool in material research and industrial processing.
NASA Astrophysics Data System (ADS)
Zhu, Yanwei; Yi, Fajun; Meng, Songhe; Zhuo, Lijun; Pan, Weizhen
2017-11-01
Improving the surface heat load measurement technique for vehicles in aerodynamic heating environments is imperative, regarding aspects of both the apparatus design and identification efficiency. A simple novel apparatus is designed for heat load identification, taking into account the lessons learned from several aerodynamic heating measurement devices. An inverse finite difference scheme (invFDM) for the apparatus is studied to identify its surface heat flux from the interior temperature measurements with high efficiency. A weighted piecewise regression filter is also proposed for temperature measurement prefiltering. Preliminary verification of the invFDM scheme and the filter is accomplished via numerical simulation experiments. Three specific pieces of apparatus have been concretely designed and fabricated using different sensing materials. The aerodynamic heating process is simulated by an inductively coupled plasma wind tunnel facility. The identification of surface temperature and heat flux from the temperature measurements is performed by invFDM. The results validate the high efficiency, reliability and feasibility of heat load measurements with different heat flux levels utilizing the designed apparatus and proposed method.
Resonant-cavity apparatus for cytometry or particle analysis
Gourley, Paul L.
1998-01-01
A resonant-cavity apparatus for cytometry or particle analysis. The apparatus comprises a resonant optical cavity having an analysis region within the cavity for containing one or more biological cells or dielectric particles to be analyzed. In the presence of a cell or particle, a light beam in the form of spontaneous emission or lasing is generated within the resonant optical cavity and is encoded with information about the cell or particle. An analysis means including a spectrometer and/or a pulse-height analyzer is provided within the apparatus for recovery of the information from the light beam to determine a size, shape, identification or other characteristics about the cells or particles being analyzed. The recovered information can be grouped in a multi-dimensional coordinate space for identification of particular types of cells or particles. In some embodiments of the apparatus, the resonant optical cavity can be formed, at least in part, from a vertical-cavity surface-emitting laser. The apparatus and method are particularly suited to the analysis of biological cells, including blood cells, and can further include processing means for manipulating, sorting, or eradicating cells after analysis thereof.
Process and apparatus for the production of BI-213 cations
Horwitz, E. Philip; Hines, John J.; Chiarizia, Renato; Dietz, Mark
1998-01-01
A process for producing substantially impurity-free Bi-213 cations is disclosed. An aqueous acid feed solution containing Ac-225 cations is contacted with an ion exchange medium to bind the Ac-225 cations and form an Ac-225-laden ion exchange medium. The bound Ac-225 incubates on the ion exchange medium to form Bi-213 cations by radioactive decay. The Bi-213 cations are then recovered from the Ac-225-laden ion exchange medium to form a substantially impurity-free aqueous Bi-213 cation acid solution. An apparatus for carrying out this process is also disclosed.
Markovian limit for a reduced operation-valued stochastic process
NASA Astrophysics Data System (ADS)
Barchielli, Alberto
1987-04-01
Operation-valued stochastic processes give a formalization of the concept of continuous (in time) measurements in quantum mechanics. In this article, a first stage M of a measuring apparatus coupled to the system S is explicitly introduced, and continuous measurement of some observables of M is considered (one can speak of an indirect continuous measurement on S). When the degrees of freedom of the measuring apparatus M are eliminated and the weak coupling limit is taken, it is shown that an operation-valued stochastic process describing a direct continuous observation of the system S is obtained.
Process and apparatus for the production of Bi-213 cations
Horwitz, E.P.; Hines, J.J.; Chiarizia, R.; Dietz, M.
1998-12-29
A process for producing substantially impurity-free Bi-213 cations is disclosed. An aqueous acid feed solution containing Ac-225 cations is contacted with an ion exchange medium to bind the Ac-225 cations and form an Ac-225-laden ion exchange medium. The bound Ac-225 incubates on the ion exchange medium to form Bi-213 cations by radioactive decay. The Bi-213 cations are then recovered from the Ac-225-laden ion exchange medium to form a substantially impurity-free aqueous Bi-213 cation acid solution. An apparatus for carrying out this process is also disclosed. 7 figs.
Bagless transfer process and apparatus for radioactive waste confinement
Maxwell, D.N.; Hones, R.H.; Rogers, M.L.
1998-04-14
A process and apparatus are provided for removing radioactive material from a glovebox, placing the material in a stainless steel storage vessel in communication with the glovebox, and sealing the vessel with a welded plug. The vessel is then severed along the weld, a lower half of the plug forming a closure for the vessel. The remaining welded plug half provides a seal for the remnant portion of the vessel and thereby maintains the sealed integrity of the glovebox. 7 figs.
Bagless transfer process and apparatus for radioactive waste confinement
Maxwell, David N.; Hones, Robert H.; Rogers, M. Lane
1998-01-01
A process and apparatus is provided for removing radioactive material from a glovebox, placing the material in a stainless steel storage vessel in communication with the glovebox, and sealing the vessel with a welded plug. The vessel is then severed along the weld, a lower half of the plug forming a closure for the vessel. The remaining welded plug half provides a seal for the remnant portion of the vessel and thereby maintains the sealed integrity of the glovebox.
APPARATUS FOR THE PURIFICATION OF CALCIUM
Burnett, R.L.
1953-08-25
The present patent claims and describes an apparatus adapted to carry out a new process for the purification of calcium containing an alkali metal as impurity. The process consists of distilling the impure caldium in the presence of an inert gas and at a reduced pressure, condensing substantially pure calcium on a condensing surface of iron or a ferrous alloy and condensing the alkali metal on a separate surface, the two condensing surfaces being maintained at suitable temperatures by separate cooling means.
Apparatus for fabricating continuous lengths of superconductor
Kroeger, Donald M.; List, III, Frederick A.
2002-01-01
A process and apparatus for manufacturing a superconductor. The process is accomplished by depositing a superconductor precursor powder on a continuous length of a first substrate ribbon, overlaying a continuous length of a second substrate ribbon on said first substrate ribbon, and applying sufficient pressure to form a bound layered superconductor comprising a layer of said superconducting precursor powder between said first substrate ribbon and said second substrates ribbon. The layered superconductor is then heat treated to establish the superconducting phase of said superconductor precursor powder.
Apparatus for fabricating continuous lengths of superconductor
Kroeger, Donald M.; List, III, Frederick A.
2001-01-01
A process and apparatus for manufacturing a superconductor. The process is accomplished by depositing a superconductor precursor powder on a continuous length of a first substrate ribbon, overlaying a continuous length of a second substrate ribbon on said first substrate ribbon, and applying sufficient pressure to form a bound layered superconductor comprising a layer of said superconducting precursor powder between said first substrate ribbon and said second substrates ribbon. The layered superconductor is then heat treated to establish the superconducting phase of said superconductor precursor powder.
SNMR pulse sequence phase cycling
Walsh, David O; Grunewald, Elliot D
2013-11-12
Technologies applicable to SNMR pulse sequence phase cycling are disclosed, including SNMR acquisition apparatus and methods, SNMR processing apparatus and methods, and combinations thereof. SNMR acquisition may include transmitting two or more SNMR pulse sequences and applying a phase shift to a pulse in at least one of the pulse sequences, according to any of a variety cycling techniques. SNMR processing may include combining SNMR from a plurality of pulse sequences comprising pulses of different phases, so that desired signals are preserved and indesired signals are canceled.
Method and apparatus for measuring flow velocity using matched filters
Raptis, Apostolos C.
1983-01-01
An apparatus and method for measuring the flow velocities of individual phase flow components of a multiphase flow utilizes matched filters. Signals arising from flow noise disturbance are extracted from the flow, at upstream and downstream locations. The signals are processed through pairs of matched filters which are matched to the flow disturbance frequency characteristics of the phase flow component to be measured. The processed signals are then cross-correlated to determine the transit delay time of the phase flow component between sensing positions.
Apparatus and process for collection of gas and vapor samples
Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA
2008-04-01
A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.
Process and apparatus for solvent extraction of oil from oil-containing diatomite ore
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karnofsky, G. B.
1980-12-16
A process for solvent extraction of oil from oil bearing diatomite ore and an apparatus for use therewith, wherein the ore is extracted by countercurrent decantation with a hydrocarbon solvent, solvent is recovered from the extract by multiple effect evaporation followed by stripping, and the spent diatomite is contacted with water to displace a major portion of the solvent therefrom, and solvent is recovered from the aqueous slurry of the spent diatomite by stripping with steam at superatmospheric pressure.