Sample records for producing high fidelity

  1. Generation of high-fidelity four-photon cluster state and quantum-domain demonstration of one-way quantum computing.

    PubMed

    Tokunaga, Yuuki; Kuwashiro, Shin; Yamamoto, Takashi; Koashi, Masato; Imoto, Nobuyuki

    2008-05-30

    We experimentally demonstrate a simple scheme for generating a four-photon entangled cluster state with fidelity over 0.860+/-0.015. We show that the fidelity is high enough to guarantee that the produced state is distinguished from Greenberger-Horne-Zeilinger, W, and Dicke types of genuine four-qubit entanglement. We also demonstrate basic operations of one-way quantum computing using the produced state and show that the output state fidelities surpass classical bounds, which indicates that the entanglement in the produced state essentially contributes to the quantum operation.

  2. A comparison of select image-compression algorithms for an electronic still camera

    NASA Technical Reports Server (NTRS)

    Nerheim, Rosalee

    1989-01-01

    This effort is a study of image-compression algorithms for an electronic still camera. An electronic still camera can record and transmit high-quality images without the use of film, because images are stored digitally in computer memory. However, high-resolution images contain an enormous amount of information, and will strain the camera's data-storage system. Image compression will allow more images to be stored in the camera's memory. For the electronic still camera, a compression algorithm that produces a reconstructed image of high fidelity is most important. Efficiency of the algorithm is the second priority. High fidelity and efficiency are more important than a high compression ratio. Several algorithms were chosen for this study and judged on fidelity, efficiency and compression ratio. The transform method appears to be the best choice. At present, the method is compressing images to a ratio of 5.3:1 and producing high-fidelity reconstructed images.

  3. Phosphate-binding pocket in Dicer-2 PAZ domain for high-fidelity siRNA production

    PubMed Central

    Kandasamy, Suresh K.

    2016-01-01

    The enzyme Dicer produces small silencing RNAs such as micro-RNAs (miRNAs) and small interfering RNAs (siRNAs). In Drosophila, Dicer-1 produces ∼22–24-nt miRNAs from pre-miRNAs, whereas Dicer-2 makes 21-nt siRNAs from long double-stranded RNAs (dsRNAs). How Dicer-2 precisely makes 21-nt siRNAs with a remarkably high fidelity is unknown. Here we report that recognition of the 5′-monophosphate of a long dsRNA substrate by a phosphate-binding pocket in the Dicer-2 PAZ (Piwi, Argonaute, and Zwille/Pinhead) domain is crucial for the length fidelity, but not the efficiency, in 21-nt siRNA production. Loss of the length fidelity, meaning increased length heterogeneity of siRNAs, caused by point mutations in the phosphate-binding pocket of the Dicer-2 PAZ domain decreased RNA silencing activity in vivo, showing the importance of the high fidelity to make 21-nt siRNAs. We propose that the 5′-monophosphate of a long dsRNA substrate is anchored by the phosphate-binding pocket in the Dicer-2 PAZ domain and the distance between the pocket and the RNA cleavage active site in the RNaseIII domain corresponds to the 21-nt pitch in the A-form duplex of a long dsRNA substrate, resulting in high-fidelity 21-nt siRNA production. This study sheds light on the molecular mechanism by which Dicer-2 produces 21-nt siRNAs with a remarkably high fidelity for efficient RNA silencing. PMID:27872309

  4. Economical Unsteady High-Fidelity Aerodynamics for Structural Optimization with a Flutter Constraint

    NASA Technical Reports Server (NTRS)

    Bartels, Robert E.; Stanford, Bret K.

    2017-01-01

    Structural optimization with a flutter constraint for a vehicle designed to fly in the transonic regime is a particularly difficult task. In this speed range, the flutter boundary is very sensitive to aerodynamic nonlinearities, typically requiring high-fidelity Navier-Stokes simulations. However, the repeated application of unsteady computational fluid dynamics to guide an aeroelastic optimization process is very computationally expensive. This expense has motivated the development of methods that incorporate aspects of the aerodynamic nonlinearity, classical tools of flutter analysis, and more recent methods of optimization. While it is possible to use doublet lattice method aerodynamics, this paper focuses on the use of an unsteady high-fidelity aerodynamic reduced order model combined with successive transformations that allows for an economical way of utilizing high-fidelity aerodynamics in the optimization process. This approach is applied to the common research model wing structural design. As might be expected, the high-fidelity aerodynamics produces a heavier wing than that optimized with doublet lattice aerodynamics. It is found that the optimized lower skin of the wing using high-fidelity aerodynamics differs significantly from that using doublet lattice aerodynamics.

  5. High fidelity simulations of infrared imagery with animated characters

    NASA Astrophysics Data System (ADS)

    Näsström, F.; Persson, A.; Bergström, D.; Berggren, J.; Hedström, J.; Allvar, J.; Karlsson, M.

    2012-06-01

    High fidelity simulations of IR signatures and imagery tend to be slow and do not have effective support for animation of characters. Simplified rendering methods based on computer graphics methods can be used to overcome these limitations. This paper presents a method to combine these tools and produce simulated high fidelity thermal IR data of animated people in terrain. Infrared signatures for human characters have been calculated using RadThermIR. To handle multiple character models, these calculations use a simplified material model for the anatomy and clothing. Weather and temperature conditions match the IR-texture used in the terrain model. The calculated signatures are applied to the animated 3D characters that, together with the terrain model, are used to produce high fidelity IR imagery of people or crowds. For high level animation control and crowd simulations, HLAS (High Level Animation System) has been developed. There are tools available to create and visualize skeleton based animations, but tools that allow control of the animated characters on a higher level, e.g. for crowd simulation, are usually expensive and closed source. We need the flexibility of HLAS to add animation into an HLA enabled sensor system simulation framework.

  6. Effect of diatomic molecular properties on binary laser pulse optimizations of quantum gate operations.

    PubMed

    Zaari, Ryan R; Brown, Alex

    2011-07-28

    The importance of the ro-vibrational state energies on the ability to produce high fidelity binary shaped laser pulses for quantum logic gates is investigated. The single frequency 2-qubit ACNOT(1) and double frequency 2-qubit NOT(2) quantum gates are used as test cases to examine this behaviour. A range of diatomics is sampled. The laser pulses are optimized using a genetic algorithm for binary (two amplitude and two phase parameter) variation on a discretized frequency spectrum. The resulting trends in the fidelities were attributed to the intrinsic molecular properties and not the choice of method: a discretized frequency spectrum with genetic algorithm optimization. This is verified by using other common laser pulse optimization methods (including iterative optimal control theory), which result in the same qualitative trends in fidelity. The results differ from other studies that used vibrational state energies only. Moreover, appropriate choice of diatomic (relative ro-vibrational state arrangement) is critical for producing high fidelity optimized quantum logic gates. It is also suggested that global phase alignment imposes a significant restriction on obtaining high fidelity regions within the parameter search space. Overall, this indicates a complexity in the ability to provide appropriate binary laser pulse control of diatomics for molecular quantum computing. © 2011 American Institute of Physics

  7. Creation of a Rapid High-Fidelity Aerodynamics Module for a Multidisciplinary Design Environment

    NASA Technical Reports Server (NTRS)

    Srinivasan, Muktha; Whittecar, William; Edwards, Stephen; Mavris, Dimitri N.

    2012-01-01

    In the traditional aerospace vehicle design process, each successive design phase is accompanied by an increment in the modeling fidelity of the disciplinary analyses being performed. This trend follows a corresponding shrinking of the design space as more and more design decisions are locked in. The correlated increase in knowledge about the design and decrease in design freedom occurs partly because increases in modeling fidelity are usually accompanied by significant increases in the computational expense of performing the analyses. When running high fidelity analyses, it is not usually feasible to explore a large number of variations, and so design space exploration is reserved for conceptual design, and higher fidelity analyses are run only once a specific point design has been selected to carry forward. The designs produced by this traditional process have been recognized as being limited by the uncertainty that is present early on due to the use of lower fidelity analyses. For example, uncertainty in aerodynamics predictions produces uncertainty in trajectory optimization, which can impact overall vehicle sizing. This effect can become more significant when trajectories are being shaped by active constraints. For example, if an optimal trajectory is running up against a normal load factor constraint, inaccuracies in the aerodynamic coefficient predictions can cause a feasible trajectory to be considered infeasible, or vice versa. For this reason, a trade must always be performed between the desired fidelity and the resources available. Apart from this trade between fidelity and computational expense, it is very desirable to use higher fidelity analyses earlier in the design process. A large body of work has been performed to this end, led by efforts in the area of surrogate modeling. In surrogate modeling, an up-front investment is made by running a high fidelity code over a Design of Experiments (DOE); once completed, the DOE data is used to create a surrogate model, which captures the relationships between input variables and responses into regression equations. Depending on the dimensionality of the problem and the fidelity of the code for which a surrogate model is being created, the initial DOE can itself be computationally prohibitive to run. Cokriging, a modeling approach from the field of geostatistics, provides a desirable compromise between computational expense and fidelity. To do this, cokriging leverages a large body of data generated by a low fidelity analysis, combines it with a smaller set of data from a higher fidelity analysis, and creates a kriging surrogate model with prediction fidelity approaching that of the higher fidelity analysis. When integrated into a multidisciplinary environment, a disciplinary analysis module employing cokriging can raise the analysis fidelity without drastically impacting the expense of design iterations. This is demonstrated through the creation of an aerodynamics analysis module in NASA s OpenMDAO framework. Aerodynamic analyses including Missile DATCOM, APAS, and USM3D are leveraged to create high fidelity aerodynamics decks for parametric vehicle geometries, which are created in NASA s Vehicle Sketch Pad (VSP). Several trade studies are performed to examine the achieved level of model fidelity, and the overall impact to vehicle design is quantified.

  8. GIS Data Based Automatic High-Fidelity 3D Road Network Modeling

    NASA Technical Reports Server (NTRS)

    Wang, Jie; Shen, Yuzhong

    2011-01-01

    3D road models are widely used in many computer applications such as racing games and driving simulations_ However, almost all high-fidelity 3D road models were generated manually by professional artists at the expense of intensive labor. There are very few existing methods for automatically generating 3D high-fidelity road networks, especially those existing in the real world. This paper presents a novel approach thai can automatically produce 3D high-fidelity road network models from real 2D road GIS data that mainly contain road. centerline in formation. The proposed method first builds parametric representations of the road centerlines through segmentation and fitting . A basic set of civil engineering rules (e.g., cross slope, superelevation, grade) for road design are then selected in order to generate realistic road surfaces in compliance with these rules. While the proposed method applies to any types of roads, this paper mainly addresses automatic generation of complex traffic interchanges and intersections which are the most sophisticated elements in the road networks

  9. Hybrid surrogate-model-based multi-fidelity efficient global optimization applied to helicopter blade design

    NASA Astrophysics Data System (ADS)

    Ariyarit, Atthaphon; Sugiura, Masahiko; Tanabe, Yasutada; Kanazaki, Masahiro

    2018-06-01

    A multi-fidelity optimization technique by an efficient global optimization process using a hybrid surrogate model is investigated for solving real-world design problems. The model constructs the local deviation using the kriging method and the global model using a radial basis function. The expected improvement is computed to decide additional samples that can improve the model. The approach was first investigated by solving mathematical test problems. The results were compared with optimization results from an ordinary kriging method and a co-kriging method, and the proposed method produced the best solution. The proposed method was also applied to aerodynamic design optimization of helicopter blades to obtain the maximum blade efficiency. The optimal shape obtained by the proposed method achieved performance almost equivalent to that obtained using the high-fidelity, evaluation-based single-fidelity optimization. Comparing all three methods, the proposed method required the lowest total number of high-fidelity evaluation runs to obtain a converged solution.

  10. Improvements of ModalMax High-Fidelity Piezoelectric Audio Device

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.

    2005-01-01

    ModalMax audio speakers have been enhanced by innovative means of tailoring the vibration response of thin piezoelectric plates to produce a high-fidelity audio response. The ModalMax audio speakers are 1 mm in thickness. The device completely supplants the need to have a separate driver and speaker cone. ModalMax speakers can perform the same applications of cone speakers, but unlike cone speakers, ModalMax speakers can function in harsh environments such as high humidity or extreme wetness. New design features allow the speakers to be completely submersed in salt water, making them well suited for maritime applications. The sound produced from the ModalMax audio speakers has sound spatial resolution that is readily discernable for headset users.

  11. Effect of laser pulse shaping parameters on the fidelity of quantum logic gates.

    PubMed

    Zaari, Ryan R; Brown, Alex

    2012-09-14

    The effect of varying parameters specific to laser pulse shaping instruments on resulting fidelities for the ACNOT(1), NOT(2), and Hadamard(2) quantum logic gates are studied for the diatomic molecule (12)C(16)O. These parameters include varying the frequency resolution, adjusting the number of frequency components and also varying the amplitude and phase at each frequency component. A time domain analytic form of the original discretized frequency domain laser pulse function is derived, providing a useful means to infer the resulting pulse shape through variations to the aforementioned parameters. We show that amplitude variation at each frequency component is a crucial requirement for optimal laser pulse shaping, whereas phase variation provides minimal contribution. We also show that high fidelity laser pulses are dependent upon the frequency resolution and increasing the number of frequency components provides only a small incremental improvement to quantum gate fidelity. Analysis through use of the pulse area theorem confirms the resulting population dynamics for one or two frequency high fidelity laser pulses and implies similar dynamics for more complex laser pulse shapes. The ability to produce high fidelity laser pulses that provide both population control and global phase alignment is attributed greatly to the natural evolution phase alignment of the qubits involved within the quantum logic gate operation.

  12. High-fidelity large area nano-patterning of silicon with femtosecond light sheet

    NASA Astrophysics Data System (ADS)

    Sidhu, Mehra S.; Munjal, Pooja; Singh, Kamal P.

    2018-01-01

    We employ a femtosecond light sheet generated by a cylindrical lens to rapidly produce high-fidelity nano-structures over large area on silicon surface. The Fourier analysis of electron microscopy images of the laser-induced surface structures reveals sharp peaks indicating good homogeneity. We observed an emergence of second-order spatial periodicity on increasing the scan speed. Our reliable approach may rapidly nano-pattern curved solid surfaces and tiny objects for diverse potential applications in optical devices, structural coloring, plasmonic substrates and in high-harmonic generation.

  13. High-Fidelity Trapped-Ion Quantum Logic Using Near-Field Microwaves.

    PubMed

    Harty, T P; Sepiol, M A; Allcock, D T C; Ballance, C J; Tarlton, J E; Lucas, D M

    2016-09-30

    We demonstrate a two-qubit logic gate driven by near-field microwaves in a room-temperature microfabricated surface ion trap. We introduce a dynamically decoupled gate method, which stabilizes the qubits against fluctuating energy shifts and avoids the need to null the microwave field. We use the gate to produce a Bell state with fidelity 99.7(1)%, after accounting for state preparation and measurement errors. The gate is applied directly to ^{43}Ca^{+} hyperfine "atomic clock" qubits (coherence time T_{2}^{*}≈50  s) using the oscillating magnetic field gradient produced by an integrated microwave electrode.

  14. High-Fidelity Simulation for Advanced Cardiac Life Support Training

    PubMed Central

    Davis, Lindsay E.; Storjohann, Tara D.; Spiegel, Jacqueline J.; Beiber, Kellie M.

    2013-01-01

    Objective. To determine whether a high-fidelity simulation technique compared with lecture would produce greater improvement in advanced cardiac life support (ACLS) knowledge, confidence, and overall satisfaction with the training method. Design. This sequential, parallel-group, crossover trial randomized students into 2 groups distinguished by the sequence of teaching technique delivered for ACLS instruction (ie, classroom lecture vs high-fidelity simulation exercise). Assessment. Test scores on a written examination administered at baseline and after each teaching technique improved significantly from baseline in all groups but were highest when lecture was followed by simulation. Simulation was associated with a greater degree of overall student satisfaction compared with lecture. Participation in a simulation exercise did not improve pharmacy students’ knowledge of ACLS more than attending a lecture, but it was associated with improved student confidence in skills and satisfaction with learning and application. Conclusions. College curricula should incorporate simulation to complement but not replace lecture for ACLS education. PMID:23610477

  15. High-fidelity simulation for advanced cardiac life support training.

    PubMed

    Davis, Lindsay E; Storjohann, Tara D; Spiegel, Jacqueline J; Beiber, Kellie M; Barletta, Jeffrey F

    2013-04-12

    OBJECTIVE. To determine whether a high-fidelity simulation technique compared with lecture would produce greater improvement in advanced cardiac life support (ACLS) knowledge, confidence, and overall satisfaction with the training method. DESIGN. This sequential, parallel-group, crossover trial randomized students into 2 groups distinguished by the sequence of teaching technique delivered for ACLS instruction (ie, classroom lecture vs high-fidelity simulation exercise). ASSESSMENT. Test scores on a written examination administered at baseline and after each teaching technique improved significantly from baseline in all groups but were highest when lecture was followed by simulation. Simulation was associated with a greater degree of overall student satisfaction compared with lecture. Participation in a simulation exercise did not improve pharmacy students' knowledge of ACLS more than attending a lecture, but it was associated with improved student confidence in skills and satisfaction with learning and application. CONCLUSIONS. College curricula should incorporate simulation to complement but not replace lecture for ACLS education.

  16. A unified, multifidelity quasi-newton optimization method with application to aero-structural designa

    NASA Astrophysics Data System (ADS)

    Bryson, Dean Edward

    A model's level of fidelity may be defined as its accuracy in faithfully reproducing a quantity or behavior of interest of a real system. Increasing the fidelity of a model often goes hand in hand with increasing its cost in terms of time, money, or computing resources. The traditional aircraft design process relies upon low-fidelity models for expedience and resource savings. However, the reduced accuracy and reliability of low-fidelity tools often lead to the discovery of design defects or inadequacies late in the design process. These deficiencies result either in costly changes or the acceptance of a configuration that does not meet expectations. The unknown opportunity cost is the discovery of superior vehicles that leverage phenomena unknown to the designer and not illuminated by low-fidelity tools. Multifidelity methods attempt to blend the increased accuracy and reliability of high-fidelity models with the reduced cost of low-fidelity models. In building surrogate models, where mathematical expressions are used to cheaply approximate the behavior of costly data, low-fidelity models may be sampled extensively to resolve the underlying trend, while high-fidelity data are reserved to correct inaccuracies at key locations. Similarly, in design optimization a low-fidelity model may be queried many times in the search for new, better designs, with a high-fidelity model being exercised only once per iteration to evaluate the candidate design. In this dissertation, a new multifidelity, gradient-based optimization algorithm is proposed. It differs from the standard trust region approach in several ways, stemming from the new method maintaining an approximation of the inverse Hessian, that is the underlying curvature of the design problem. Whereas the typical trust region approach performs a full sub-optimization using the low-fidelity model at every iteration, the new technique finds a suitable descent direction and focuses the search along it, reducing the number of low-fidelity evaluations required. This narrowing of the search domain also alleviates the burden on the surrogate model corrections between the low- and high-fidelity data. Rather than requiring the surrogate to be accurate in a hyper-volume bounded by the trust region, the model needs only to be accurate along the forward-looking search direction. Maintaining the approximate inverse Hessian also allows the multifidelity algorithm to revert to high-fidelity optimization at any time. In contrast, the standard approach has no memory of the previously-computed high-fidelity data. The primary disadvantage of the proposed algorithm is that it may require modifications to the optimization software, whereas standard optimizers may be used as black-box drivers in the typical trust region method. A multifidelity, multidisciplinary simulation of aeroelastic vehicle performance is developed to demonstrate the optimization method. The numerical physics models include body-fitted Euler computational fluid dynamics; linear, panel aerodynamics; linear, finite-element computational structural mechanics; and reduced, modal structural bases. A central element of the multifidelity, multidisciplinary framework is a shared parametric, attributed geometric representation that ensures the analysis inputs are consistent between disciplines and fidelities. The attributed geometry also enables the transfer of data between disciplines. The new optimization algorithm, a standard trust region approach, and a single-fidelity quasi-Newton method are compared for a series of analytic test functions, using both polynomial chaos expansions and kriging to correct discrepancies between fidelity levels of data. In the aggregate, the new method requires fewer high-fidelity evaluations than the trust region approach in 51% of cases, and the same number of evaluations in 18%. The new approach also requires fewer low-fidelity evaluations, by up to an order of magnitude, in almost all cases. The efficacy of both multifidelity methods compared to single-fidelity optimization depends significantly on the behavior of the high-fidelity model and the quality of the low-fidelity approximation, though savings are realized in a large number of cases. The multifidelity algorithm is also compared to the single-fidelity quasi-Newton method for complex aeroelastic simulations. The vehicle design problem includes variables for planform shape, structural sizing, and cruise condition with constraints on trim and structural stresses. Considering the objective function reduction versus computational expenditure, the multifidelity process performs better in three of four cases in early iterations. However, the enforcement of a contracting trust region slows the multifidelity progress. Even so, leveraging the approximate inverse Hessian, the optimization can be seamlessly continued using high-fidelity data alone. Ultimately, the proposed new algorithm produced better designs in all four cases. Investigating the return on investment in terms of design improvement per computational hour confirms that the multifidelity advantage is greatest in early iterations, and managing the transition to high-fidelity optimization is critical.

  17. Numerical study of phase conjugation in stimulated Brillouin scattering from an optical waveguide

    NASA Astrophysics Data System (ADS)

    Lehmberg, R. H.

    1983-05-01

    Stimulated Brillouin scattering (SBS) in a multimode optical waveguide is examined, and the parameters that affect the wavefront conjugation fidelity are studied. The nonlinear propagation code is briefly described and the calculated quantities are defined. The parameter study in the low reflectivity limit is described, and the effects of pump depletion are considered. The waveguide produced significantly higher fidelities than the focused configuration, in agreement with several experimental studies. The light scattered back through the phase aberrator exhibited a farfield intenstiy profile closely matching that of the incident beam; however, the nearfield intensity exhibited large and rapid spatial inhomogeneities across the entire aberrator, even for conjugation fidelities as high as 98 percent. In the absence of pump depletion, the fidelity increased with average pump intensity for amplitude gains up to around e to the 10th and then decreased slowly and monotonically with higher intensity. For all cases, pump depletion significantly enhanced the fidelity of the wavefront conjugation by inhibiting the small-scale pulling effect.

  18. Point-of-care ultrasound education: the increasing role of simulation and multimedia resources.

    PubMed

    Lewiss, Resa E; Hoffmann, Beatrice; Beaulieu, Yanick; Phelan, Mary Beth

    2014-01-01

    This article reviews the current technology, literature, teaching models, and methods associated with simulation-based point-of-care ultrasound training. Patient simulation appears particularly well suited for learning point-of-care ultrasound, which is a required core competency for emergency medicine and other specialties. Work hour limitations have reduced the opportunities for clinical practice, and simulation enables practicing a skill multiple times before it may be used on patients. Ultrasound simulators can be categorized into 2 groups: low and high fidelity. Low-fidelity simulators are usually static simulators, meaning that they have nonchanging anatomic examples for sonographic practice. Advantages are that the model may be reused over time, and some simulators can be homemade. High-fidelity simulators are usually high-tech and frequently consist of many computer-generated cases of virtual sonographic anatomy that can be scanned with a mock probe. This type of equipment is produced commercially and is more expensive. High-fidelity simulators provide students with an active and safe learning environment and make a reproducible standardized assessment of many different ultrasound cases possible. The advantages and disadvantages of using low- versus high-fidelity simulators are reviewed. An additional concept used in simulation-based ultrasound training is blended learning. Blended learning may include face-to-face or online learning often in combination with a learning management system. Increasingly, with simulation and Web-based learning technologies, tools are now available to medical educators for the standardization of both ultrasound skills training and competency assessment.

  19. Crystal plasticity modeling of β phase deformation in Ti-6Al-4V

    NASA Astrophysics Data System (ADS)

    Moore, John A.; Barton, Nathan R.; Florando, Jeff; Mulay, Rupalee; Kumar, Mukul

    2017-10-01

    Ti-6Al-4V is an alloy of titanium that dominates titanium usage in applications ranging from mass-produced consumer goods to high-end aerospace parts. The material’s structure on a microscale is known to affect its mechanical properties but these effects are not fully understood. Specifically, this work will address the effects of low volume fraction intergranular β phase on Ti-6Al-4V’s mechanical response during the transition from elastic to plastic deformation. A crystal plasticity-based finite element model is used to fully resolve the deformation of the β phase for the first time. This high fidelity model captures mechanisms difficult to access via experiments or lower fidelity models. The results are used to assess lower fidelity modeling assumptions and identify phenomena that have ramifications for failure of the material.

  20. Extending the Conceptualization of Listening Fidelity

    ERIC Educational Resources Information Center

    Fitch-Hauser, Margaret; Powers, William G.; O'Brien, Kelley; Hanson, Scott

    2007-01-01

    An exploration of variables potentially related to Listening Fidelity (LF) was conducted through two separate studies. Study 1 indicated that when the potential fidelity of the stimulus message was varied as a function of the number of words and time length, the message with lowest potential fidelity produced significantly lower LF than either the…

  1. Time to unravel the conceptual confusion of authenticity and fidelity and their contribution to learning within simulation-based nurse education. A discussion paper.

    PubMed

    Bland, Andrew J; Topping, Annie; Tobbell, Jane

    2014-07-01

    High-fidelity patient simulation is a method of education increasingly utilised by educators of nursing to provide authentic learning experiences. Fidelity and authenticity, however, are not conceptually equivalent. Whilst fidelity is important when striving to replicate a life experience such as clinical practice, authenticity can be produced with low fidelity. A challenge for educators of undergraduate nursing is to ensure authentic representation of the clinical situation which is a core component for potential success. What is less clear is the relationship between fidelity and authenticity in the context of simulation based learning. Authenticity does not automatically follow fidelity and as a result, educators of nursing cannot assume that embracing the latest technology-based educational tools will in isolation provide a learning environment perceived authentic by the learner. As nursing education programmes increasingly adopt simulators that offer the possibility of representing authentic real world situations, there is an urgency to better articulate and understand the terms fidelity and authenticity. Without such understanding there is a real danger that simulation as a teaching and learning resource in nurse education will never reach its potential and be misunderstood, creating a potential barrier to learning. This paper examines current literature to promote discussion within nurse education, concluding that authenticity in the context of simulation-based learning is complex, relying on far more than engineered fidelity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Crystal plasticity modeling of β phase deformation in Ti-6Al-4V

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, John A.; Barton, Nathan R.; Florando, Jeff

    Ti-6Al-4V is an alloy of titanium that dominates titanium usage in applications ranging from mass-produced consumer goods to high-end aerospace parts. The material's structure on a microscale is known to affect its mechanical properties but these effects are not fully understood. Specifically, this work will address the effects of low volume fraction intergranular β phase on Ti-6Al-4V's mechanical response during the transition from elastic to plastic deformation. A crystal plasticity-based finite element model is used to fully resolve the deformation of the β phase for the first time. This high fidelity model captures mechanisms difficult to access via experiments ormore » lower fidelity models. Lastly, the results are used to assess lower fidelity modeling assumptions and identify phenomena that have ramifications for failure of the material.« less

  3. Crystal plasticity modeling of β phase deformation in Ti-6Al-4V

    DOE PAGES

    Moore, John A.; Barton, Nathan R.; Florando, Jeff; ...

    2017-08-24

    Ti-6Al-4V is an alloy of titanium that dominates titanium usage in applications ranging from mass-produced consumer goods to high-end aerospace parts. The material's structure on a microscale is known to affect its mechanical properties but these effects are not fully understood. Specifically, this work will address the effects of low volume fraction intergranular β phase on Ti-6Al-4V's mechanical response during the transition from elastic to plastic deformation. A crystal plasticity-based finite element model is used to fully resolve the deformation of the β phase for the first time. This high fidelity model captures mechanisms difficult to access via experiments ormore » lower fidelity models. Lastly, the results are used to assess lower fidelity modeling assumptions and identify phenomena that have ramifications for failure of the material.« less

  4. High-fidelity entanglement swapping and generation of three-qubit GHZ state using asynchronous telecom photon pair sources.

    PubMed

    Tsujimoto, Yoshiaki; Tanaka, Motoki; Iwasaki, Nobuo; Ikuta, Rikizo; Miki, Shigehito; Yamashita, Taro; Terai, Hirotaka; Yamamoto, Takashi; Koashi, Masato; Imoto, Nobuyuki

    2018-01-23

    We experimentally demonstrate a high-fidelity entanglement swapping and a generation of the Greenberger-Horne-Zeilinger (GHZ) state using polarization-entangled photon pairs at telecommunication wavelength produced by spontaneous parametric down conversion with continuous-wave pump light. While spatially separated sources asynchronously emit photon pairs, the time-resolved photon detection guarantees the temporal indistinguishability of photons without active timing synchronizations of pump lasers and/or adjustment of optical paths. In the experiment, photons are sufficiently narrowed by fiber-based Bragg gratings with the central wavelengths of 1541 nm & 1580 nm, and detected by superconducting nanowire single-photon detectors with low timing jitters. The observed fidelities of the final states for entanglement swapping and the generated three-qubit state were 0.84 ± 0.04 and 0.70 ± 0.05, respectively.

  5. Multifunctional Collaborative Modeling and Analysis Methods in Engineering Science

    NASA Technical Reports Server (NTRS)

    Ransom, Jonathan B.; Broduer, Steve (Technical Monitor)

    2001-01-01

    Engineers are challenged to produce better designs in less time and for less cost. Hence, to investigate novel and revolutionary design concepts, accurate, high-fidelity results must be assimilated rapidly into the design, analysis, and simulation process. This assimilation should consider diverse mathematical modeling and multi-discipline interactions necessitated by concepts exploiting advanced materials and structures. Integrated high-fidelity methods with diverse engineering applications provide the enabling technologies to assimilate these high-fidelity, multi-disciplinary results rapidly at an early stage in the design. These integrated methods must be multifunctional, collaborative, and applicable to the general field of engineering science and mechanics. Multifunctional methodologies and analysis procedures are formulated for interfacing diverse subdomain idealizations including multi-fidelity modeling methods and multi-discipline analysis methods. These methods, based on the method of weighted residuals, ensure accurate compatibility of primary and secondary variables across the subdomain interfaces. Methods are developed using diverse mathematical modeling (i.e., finite difference and finite element methods) and multi-fidelity modeling among the subdomains. Several benchmark scalar-field and vector-field problems in engineering science are presented with extensions to multidisciplinary problems. Results for all problems presented are in overall good agreement with the exact analytical solution or the reference numerical solution. Based on the results, the integrated modeling approach using the finite element method for multi-fidelity discretization among the subdomains is identified as most robust. The multiple-method approach is advantageous when interfacing diverse disciplines in which each of the method's strengths are utilized. The multifunctional methodology presented provides an effective mechanism by which domains with diverse idealizations are interfaced. This capability rapidly provides the high-fidelity results needed in the early design phase. Moreover, the capability is applicable to the general field of engineering science and mechanics. Hence, it provides a collaborative capability that accounts for interactions among engineering analysis methods.

  6. A simple, rapid, high-fidelity and cost-effective PCR-based two-step DNA synthesis method for long gene sequences.

    PubMed

    Xiong, Ai-Sheng; Yao, Quan-Hong; Peng, Ri-He; Li, Xian; Fan, Hui-Qin; Cheng, Zong-Ming; Li, Yi

    2004-07-07

    Chemical synthesis of DNA sequences provides a powerful tool for modifying genes and for studying gene function, structure and expression. Here, we report a simple, high-fidelity and cost-effective PCR-based two-step DNA synthesis (PTDS) method for synthesis of long segments of DNA. The method involves two steps. (i) Synthesis of individual fragments of the DNA of interest: ten to twelve 60mer oligonucleotides with 20 bp overlap are mixed and a PCR reaction is carried out with high-fidelity DNA polymerase Pfu to produce DNA fragments that are approximately 500 bp in length. (ii) Synthesis of the entire sequence of the DNA of interest: five to ten PCR products from the first step are combined and used as the template for a second PCR reaction using high-fidelity DNA polymerase pyrobest, with the two outermost oligonucleotides as primers. Compared with the previously published methods, the PTDS method is rapid (5-7 days) and suitable for synthesizing long segments of DNA (5-6 kb) with high G + C contents, repetitive sequences or complex secondary structures. Thus, the PTDS method provides an alternative tool for synthesizing and assembling long genes with complex structures. Using the newly developed PTDS method, we have successfully obtained several genes of interest with sizes ranging from 1.0 to 5.4 kb.

  7. First-Order Model Management With Variable-Fidelity Physics Applied to Multi-Element Airfoil Optimization

    NASA Technical Reports Server (NTRS)

    Alexandrov, N. M.; Nielsen, E. J.; Lewis, R. M.; Anderson, W. K.

    2000-01-01

    First-order approximation and model management is a methodology for a systematic use of variable-fidelity models or approximations in optimization. The intent of model management is to attain convergence to high-fidelity solutions with minimal expense in high-fidelity computations. The savings in terms of computationally intensive evaluations depends on the ability of the available lower-fidelity model or a suite of models to predict the improvement trends for the high-fidelity problem, Variable-fidelity models can be represented by data-fitting approximations, variable-resolution models. variable-convergence models. or variable physical fidelity models. The present work considers the use of variable-fidelity physics models. We demonstrate the performance of model management on an aerodynamic optimization of a multi-element airfoil designed to operate in the transonic regime. Reynolds-averaged Navier-Stokes equations represent the high-fidelity model, while the Euler equations represent the low-fidelity model. An unstructured mesh-based analysis code FUN2D evaluates functions and sensitivity derivatives for both models. Model management for the present demonstration problem yields fivefold savings in terms of high-fidelity evaluations compared to optimization done with high-fidelity computations alone.

  8. Experimental demonstration of four-photon entanglement and high-fidelity teleportation.

    PubMed

    Pan, J W; Daniell, M; Gasparoni, S; Weihs, G; Zeilinger, A

    2001-05-14

    We experimentally demonstrate observation of highly pure four-photon GHZ entanglement produced by parametric down-conversion and a projective measurement. At the same time this also demonstrates teleportation of entanglement with very high purity. Not only does the achieved high visibility enable various novel tests of quantum nonlocality, it also opens the possibility to experimentally investigate various quantum computation and communication schemes with linear optics. Our technique can, in principle, be used to produce entanglement of arbitrarily high order or, equivalently, teleportation and entanglement swapping over multiple stages.

  9. Applications of quantum cloning

    NASA Astrophysics Data System (ADS)

    Pomarico, E.; Sanguinetti, B.; Sekatski, P.; Zbinden, H.; Gisin, N.

    2011-10-01

    Quantum Cloning Machines (QCMs) allow for the copying of information, within the limits imposed by quantum mechanics. These devices are particularly interesting in the high-gain regime, i.e., when one input qubit generates a state of many output qubits. In this regime, they allow for the study of certain aspects of the quantum to classical transition. The understanding of these aspects is the root of the two recent applications that we will review in this paper: the first one is the Quantum Cloning Radiometer, a device which is able to produce an absolute measure of spectral radiance. This device exploits the fact that in the quantum regime information can be copied with only finite fidelity, whereas when a state becomes macroscopic, this fidelity gradually increases to 1. Measuring the fidelity of the cloning operation then allows to precisely determine the absolute spectral radiance of the input optical source. We will then discuss whether a Quantum Cloning Machine could be used to produce a state visible by the naked human eye, and the possibility of a Bell Experiment with humans playing the role of detectors.

  10. Freeform fabrication of tissue-simulating phantoms by combining three-dimensional printing and casting

    NASA Astrophysics Data System (ADS)

    Shen, Shuwei; Zhao, Zuhua; Wang, Haili; Han, Yilin; Dong, Erbao; Liu, Bin; Liu, Wendong; Cromeens, Barrett; Adler, Brent; Besner, Gail; Ray, William; Hoehne, Brad; Xu, Ronald

    2016-03-01

    Appropriate surgical planning is important for improved clinical outcome and minimal complications in many surgical operations, such as a conjoined twin separation surgery. We combine 3D printing with casting and assembling to produce a solid phantom of high fidelity to help surgeons for better preparation of the conjoined twin separation surgery. 3D computer models of individual organs were reconstructed based on CT scanned data of the conjoined twins. The models were sliced, processed, and converted to an appropriate format for Fused Deposition Modeling (FDM). The skeletons of the phantom were printed directly by FDM using Acrylonitrile-Butadiene-Styrene (ABS) material, while internal soft organs were fabricated by casting silicon materials of different compositions in FDM printed molds. The skeleton and the internal organs were then assembled with appropriate fixtures to maintain their relative positional accuracies. The assembly was placed in a FMD printed shell mold of the patient body for further casting. For clear differentiation of different internal organs, CT contrast agents of different compositions were added in the silicon cast materials. The produced phantom was scanned by CT again and compared with that of the original computer models of the conjoined twins in order to verify the structural and positional fidelity. Our preliminary experiments showed that combining 3D printing with casting is an effective way to produce solid phantoms of high fidelity for the improved surgical planning in many clinical applications.

  11. Reaction of Basaltic Materials under High-Fidelity Venus Surface Conditions using the Glenn Extreme Environment Rig: First Results

    NASA Technical Reports Server (NTRS)

    Radoman-Shaw, Brandon; Harvey, Ralph; Costa, Gustavo; Nakley, Leah Michelle; Jacobson, Nathan S.

    2016-01-01

    Both historical and current investigations of Venus suggest that atmosphererock interactions play a critical role in the evolution of its atmosphere and crust. We have begun a series of systematic experiments designed to further our understanding of atmosphere-driven weathering and secondary mineralization of basaltic materials that may be occurring on Venus today. Our experiments expose representative igneous phases (mineral, glasses and rocks) to a high-fidelity simulation of Venus surface conditions using the NASA Glenn Extreme Environment Rig (GEER) located at the NASA Glenn Research Center in Cleveland, Ohio. GEER is a very large (800L) vessel capable of producing a long-term, high fidelity simulation of both the physical conditions (750 K and 92 bar) and atmospheric chemistry (down to the ppb-level) asso-ciated with the Venusian surface. As of this writing we have just finished the first of several planned experiments: a 42-day exposure of selected mineral, rocks and volcanic glasses. Our goal is to identify and prioritize the reactions taking place and better our understanding of their importance in Venus' climate history.

  12. Machine Learning for Discriminating Quantum Measurement Trajectories and Improving Readout.

    PubMed

    Magesan, Easwar; Gambetta, Jay M; Córcoles, A D; Chow, Jerry M

    2015-05-22

    Current methods for classifying measurement trajectories in superconducting qubit systems produce fidelities systematically lower than those predicted by experimental parameters. Here, we place current classification methods within the framework of machine learning (ML) algorithms and improve on them by investigating more sophisticated ML approaches. We find that nonlinear algorithms and clustering methods produce significantly higher assignment fidelities that help close the gap to the fidelity possible under ideal noise conditions. Clustering methods group trajectories into natural subsets within the data, which allows for the diagnosis of systematic errors. We find large clusters in the data associated with T1 processes and show these are the main source of discrepancy between our experimental and ideal fidelities. These error diagnosis techniques help provide a path forward to improve qubit measurements.

  13. Lattice Cleaving: A Multimaterial Tetrahedral Meshing Algorithm with Guarantees

    PubMed Central

    Bronson, Jonathan; Levine, Joshua A.; Whitaker, Ross

    2014-01-01

    We introduce a new algorithm for generating tetrahedral meshes that conform to physical boundaries in volumetric domains consisting of multiple materials. The proposed method allows for an arbitrary number of materials, produces high-quality tetrahedral meshes with upper and lower bounds on dihedral angles, and guarantees geometric fidelity. Moreover, the method is combinatoric so its implementation enables rapid mesh construction. These meshes are structured in a way that also allows grading, to reduce element counts in regions of homogeneity. Additionally, we provide proofs showing that both element quality and geometric fidelity are bounded using this approach. PMID:24356365

  14. Learning nursing procedures: the influence of simulator fidelity and student gender on teaching effectiveness.

    PubMed

    Grady, Janet L; Kehrer, Rosemary G; Trusty, Carole E; Entin, Eileen B; Entin, Elliot E; Brunye, Tad T

    2008-09-01

    Simulation technologies are gaining widespread acceptance across a variety of educational domains and applications. The current research examines whether basic nursing procedure training with high-fidelity versus low-fidelity mannequins results in differential skill acquisition and perceptions of simulator utility. Fifty-two first-year students were taught nasogastric tube and indwelling urinary catheter insertion in one of two ways. The first group learned nasogastric tube and urinary catheter insertion using high-fidelity and low-fidelity mannequins, respectively, and the second group learned nasogastric tube and urinary catheter insertion using low-fidelity and high-fidelity mannequins, respectively. The dependent measures included student performance on nasogastric tube and urinary catheter insertion testing, as measured by observer-based instruments, and self-report questionnaires probing student attitudes about the use of simulation in nursing education. Results demonstrated higher performance with high-fidelity than with low-fidelity mannequin training. In response to a self-report posttraining questionnaire, participants expressed a more positive attitude toward the high-fidelity mannequin, especially regarding its responsiveness and realism.

  15. Evaluating display fidelity and interaction fidelity in a virtual reality game.

    PubMed

    McMahan, Ryan P; Bowman, Doug A; Zielinski, David J; Brady, Rachael B

    2012-04-01

    In recent years, consumers have witnessed a technological revolution that has delivered more-realistic experiences in their own homes through high-definition, stereoscopic televisions and natural, gesture-based video game consoles. Although these experiences are more realistic, offering higher levels of fidelity, it is not clear how the increased display and interaction aspects of fidelity impact the user experience. Since immersive virtual reality (VR) allows us to achieve very high levels of fidelity, we designed and conducted a study that used a six-sided CAVE to evaluate display fidelity and interaction fidelity independently, at extremely high and low levels, for a VR first-person shooter (FPS) game. Our goal was to gain a better understanding of the effects of fidelity on the user in a complex, performance-intensive context. The results of our study indicate that both display and interaction fidelity significantly affect strategy and performance, as well as subjective judgments of presence, engagement, and usability. In particular, performance results were strongly in favor of two conditions: low-display, low-interaction fidelity (representative of traditional FPS games) and high-display, high-interaction fidelity (similar to the real world).

  16. Pristine Inner Experience and Descriptive Experience Sampling: Implications for Psychology

    PubMed Central

    Lapping-Carr, Leiszle R.; Heavey, Christopher L.

    2017-01-01

    Pristine inner experience is that which is directly present in awareness before it is distorted by attempts at observation or interpretation. Many psychological methods, including most introspective methods, attempt to measure some aspect of pristine inner experience (thoughts, feelings, mental imagery, sensations, etc.). We believe, however, that these methods produce unspecifiable combinations of pristine inner experience, beliefs about the self, beliefs about what inner experience should be like, inaccurate recollections, miscommunications, and other confounding influences. We argue that descriptive experience sampling (DES) can produce high fidelity descriptions of pristine inner experience. These descriptions are used to create idiographic profiles, carefully crafted, in-depth characterizations of the pristine inner experience of individuals. We believe these profiles, because they are built from moments apprehended via a method that confronts the challenges inherent in examining inner experience, are uniquely valuable in advancing the science of inner experience and psychology broadly. For example, DES observations raise important questions about the veracity of results gathered via questionnaires and other introspective methods, like casual introspection. DES findings also provide high fidelity phenomenological data that can be useful for those developing psychological theories, such as theories of emotional processing. Additionally, DES procedures may allow clinicians and clients to practice valuable skills, like bracketing presuppositions and attending to internal experiences. This paper will describe difficulties inherent in the study of pristine inner experience and discuss implications of high fidelity descriptions of pristine inner experience for psychological research, theory development, and clinical practice. PMID:29312047

  17. The effect of bench model fidelity on fluoroscopy-guided transforaminal epidural injection training: a randomized control study.

    PubMed

    Gonzalez-Cota, Alan; Chiravuri, Srinivas; Stansfield, R Brent; Brummett, Chad M; Hamstra, Stanley J

    2013-01-01

    The purpose of this study was to determine whether high-fidelity simulators provide greater benefit than low-fidelity models in training fluoroscopy-guided transforaminal epidural injection. This educational study was a single-center, prospective, randomized 3-arm pretest-posttest design with a control arm. Eighteen anesthesia and physical medicine and rehabilitation residents were instructed how to perform a fluoroscopy-guided transforaminal epidural injection and assessed by experts on a reusable injectable phantom cadaver. The high- and low-fidelity groups received 30 minutes of supervised hands-on practice according to group assignment, and the control group received 30 minutes of didactic instruction from an expert. We found no differences at posttest between the high- and low-fidelity groups on global ratings of performance (P = 0.17) or checklist scores (P = 0.81). Participants who received either form of hands-on training significantly outperformed the control group on both the global rating of performance (control vs low-fidelity, P = 0.0048; control vs high-fidelity, P = 0.0047) and the checklist (control vs low-fidelity, P = 0.0047; control vs high-fidelity, P = 0.0047). Training an epidural procedure using a low-fidelity model may be equally effective as training on a high-fidelity model. These results are consistent with previous research on a variety of interventional procedures and further demonstrate the potential impact of simple, low-fidelity training models.

  18. Application of a High-Fidelity Icing Analysis Method to a Model-Scale Rotor in Forward Flight

    NASA Technical Reports Server (NTRS)

    Narducci, Robert; Orr, Stanley; Kreeger, Richard E.

    2012-01-01

    An icing analysis process involving the loose coupling of OVERFLOW-RCAS for rotor performance prediction and with LEWICE3D for thermal analysis and ice accretion is applied to a model-scale rotor for validation. The process offers high-fidelity rotor analysis for the noniced and iced rotor performance evaluation that accounts for the interaction of nonlinear aerodynamics with blade elastic deformations. Ice accumulation prediction also involves loosely coupled data exchanges between OVERFLOW and LEWICE3D to produce accurate ice shapes. Validation of the process uses data collected in the 1993 icing test involving Sikorsky's Powered Force Model. Non-iced and iced rotor performance predictions are compared to experimental measurements as are predicted ice shapes.

  19. Generation and characterization of a perfect vortex beam with a large topological charge through a digital micromirror device.

    PubMed

    Chen, Yue; Fang, Zhao-Xiang; Ren, Yu-Xuan; Gong, Lei; Lu, Rong-De

    2015-09-20

    Optical vortices are associated with a spatial phase singularity. Such a beam with a vortex is valuable in optical microscopy, hyper-entanglement, and optical levitation. In these applications, vortex beams with a perfect circle shape and a large topological charge are highly desirable. But the generation of perfect vortices with high topological charges is challenging. We present a novel method to create perfect vortex beams with large topological charges using a digital micromirror device (DMD) through binary amplitude modulation and a narrow Gaussian approximation. The DMD with binary holograms encoding both the spatial amplitude and the phase could generate fast switchable, reconfigurable optical vortex beams with significantly high quality and fidelity. With either the binary Lee hologram or the superpixel binary encoding technique, we were able to generate the corresponding hologram with high fidelity and create a perfect vortex with topological charge as large as 90. The physical properties of the perfect vortex beam produced were characterized through measurements of propagation dynamics and the focusing fields. The measurements show good consistency with the theoretical simulation. The perfect vortex beam produced satisfies high-demand utilization in optical manipulation and control, momentum transfer, quantum computing, and biophotonics.

  20. Complete tomography of a high-fidelity solid-state entangled spin-photon qubit pair.

    PubMed

    De Greve, Kristiaan; McMahon, Peter L; Yu, Leo; Pelc, Jason S; Jones, Cody; Natarajan, Chandra M; Kim, Na Young; Abe, Eisuke; Maier, Sebastian; Schneider, Christian; Kamp, Martin; Höfling, Sven; Hadfield, Robert H; Forchel, Alfred; Fejer, M M; Yamamoto, Yoshihisa

    2013-01-01

    Entanglement between stationary quantum memories and photonic qubits is crucial for future quantum communication networks. Although high-fidelity spin-photon entanglement was demonstrated in well-isolated atomic and ionic systems, in the solid-state, where massively parallel, scalable networks are most realistically conceivable, entanglement fidelities are typically limited due to intrinsic environmental interactions. Distilling high-fidelity entangled pairs from lower-fidelity precursors can act as a remedy, but the required overhead scales unfavourably with the initial entanglement fidelity. With spin-photon entanglement as a crucial building block for entangling quantum network nodes, obtaining high-fidelity entangled pairs becomes imperative for practical realization of such networks. Here we report the first results of complete state tomography of a solid-state spin-photon-polarization-entangled qubit pair, using a single electron-charged indium arsenide quantum dot. We demonstrate record-high fidelity in the solid-state of well over 90%, and the first (99.9%-confidence) achievement of a fidelity that will unambiguously allow for entanglement distribution in solid-state quantum repeater networks.

  1. Gaussian functional regression for output prediction: Model assimilation and experimental design

    NASA Astrophysics Data System (ADS)

    Nguyen, N. C.; Peraire, J.

    2016-03-01

    In this paper, we introduce a Gaussian functional regression (GFR) technique that integrates multi-fidelity models with model reduction to efficiently predict the input-output relationship of a high-fidelity model. The GFR method combines the high-fidelity model with a low-fidelity model to provide an estimate of the output of the high-fidelity model in the form of a posterior distribution that can characterize uncertainty in the prediction. A reduced basis approximation is constructed upon the low-fidelity model and incorporated into the GFR method to yield an inexpensive posterior distribution of the output estimate. As this posterior distribution depends crucially on a set of training inputs at which the high-fidelity models are simulated, we develop a greedy sampling algorithm to select the training inputs. Our approach results in an output prediction model that inherits the fidelity of the high-fidelity model and has the computational complexity of the reduced basis approximation. Numerical results are presented to demonstrate the proposed approach.

  2. Nonlinear information fusion algorithms for data-efficient multi-fidelity modelling.

    PubMed

    Perdikaris, P; Raissi, M; Damianou, A; Lawrence, N D; Karniadakis, G E

    2017-02-01

    Multi-fidelity modelling enables accurate inference of quantities of interest by synergistically combining realizations of low-cost/low-fidelity models with a small set of high-fidelity observations. This is particularly effective when the low- and high-fidelity models exhibit strong correlations, and can lead to significant computational gains over approaches that solely rely on high-fidelity models. However, in many cases of practical interest, low-fidelity models can only be well correlated to their high-fidelity counterparts for a specific range of input parameters, and potentially return wrong trends and erroneous predictions if probed outside of their validity regime. Here we put forth a probabilistic framework based on Gaussian process regression and nonlinear autoregressive schemes that is capable of learning complex nonlinear and space-dependent cross-correlations between models of variable fidelity, and can effectively safeguard against low-fidelity models that provide wrong trends. This introduces a new class of multi-fidelity information fusion algorithms that provide a fundamental extension to the existing linear autoregressive methodologies, while still maintaining the same algorithmic complexity and overall computational cost. The performance of the proposed methods is tested in several benchmark problems involving both synthetic and real multi-fidelity datasets from computational fluid dynamics simulations.

  3. Teleportation of a two-mode entangled coherent state encoded with two-qubit information

    NASA Astrophysics Data System (ADS)

    Mishra, Manoj K.; Prakash, Hari

    2010-09-01

    We propose a scheme to teleport a two-mode entangled coherent state encoded with two-qubit information, which is better than the two schemes recently proposed by Liao and Kuang (2007 J. Phys. B: At. Mol. Opt. Phys. 40 1183) and by Phien and Nguyen (2008 Phys. Lett. A 372 2825) in that our scheme gives higher value of minimum assured fidelity and minimum average fidelity without using any nonlinear interactions. For involved coherent states | ± αrang, minimum average fidelity in our case is >=0.99 for |α| >= 1.6 (i.e. |α|2 >= 2.6), while previously proposed schemes referred above report the same for |α| >= 5 (i.e. |α|2 >= 25). Since it is very challenging to produce superposed coherent states of high coherent amplitude (|α|), our teleportation scheme is at the reach of modern technology.

  4. Multi-fidelity stochastic collocation method for computation of statistical moments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Xueyu, E-mail: xueyu-zhu@uiowa.edu; Linebarger, Erin M., E-mail: aerinline@sci.utah.edu; Xiu, Dongbin, E-mail: xiu.16@osu.edu

    We present an efficient numerical algorithm to approximate the statistical moments of stochastic problems, in the presence of models with different fidelities. The method extends the multi-fidelity approximation method developed in . By combining the efficiency of low-fidelity models and the accuracy of high-fidelity models, our method exhibits fast convergence with a limited number of high-fidelity simulations. We establish an error bound of the method and present several numerical examples to demonstrate the efficiency and applicability of the multi-fidelity algorithm.

  5. Initial Development of a Quadcopter Simulation Environment for Auralization

    NASA Technical Reports Server (NTRS)

    Christian, Andrew; Lawrence, Joseph

    2016-01-01

    This paper describes a recently created computer simulation of quadcopter flight dynamics for the NASA DELIVER project. The goal of this effort is to produce a simulation that includes a number of physical effects that are not usually found in other dynamics simulations (e.g., those used for flight controller development). These effects will be shown to have a significant impact on the fidelity of auralizations - entirely synthetic time-domain predictions of sound - based on this simulation when compared to a recording. High-fidelity auralizations are an important precursor to human subject tests that seek to understand the impact of vehicle configurations on noise and annoyance.

  6. High Versus Low Theoretical Fidelity Pedometer Intervention Using Social-Cognitive Theory on Steps and Self-Efficacy.

    PubMed

    Raedeke, Thomas D; Dlugonski, Deirdre

    2017-12-01

    This study was designed to compare a low versus high theoretical fidelity pedometer intervention applying social-cognitive theory on step counts and self-efficacy. Fifty-six public university employees participated in a 10-week randomized controlled trial with 2 conditions that varied in theoretical fidelity. Participants in the high theoretical fidelity condition wore a pedometer and participated in a weekly group walk followed by a meeting to discuss cognitive-behavioral strategies targeting self-efficacy. Participants in the low theoretical fidelity condition met for a group walk and also used a pedometer as a motivational tool and to monitor steps. Step counts were assessed throughout the 10-week intervention and after a no-treatment follow-up (20 weeks and 30 weeks). Self-efficacy was measured preintervention and postintervention. Participants in the high theoretical fidelity condition increased daily steps by 2,283 from preintervention to postintervention, whereas participants in the low fidelity condition demonstrated minimal change during the same time period (p = .002). Individuals attending at least 80% of the sessions in the high theoretical fidelity condition showed an increase of 3,217 daily steps (d = 1.03), whereas low attenders increased by 925 (d = 0.40). Attendance had minimal impact in the low theoretical fidelity condition. Follow-up data revealed that step counts were at least somewhat maintained. For self-efficacy, participants in the high, compared with those in the low, theoretical fidelity condition showed greater improvements. Findings highlight the importance of basing activity promotion efforts on theory. The high theoretical fidelity intervention that included cognitive-behavioral strategies targeting self-efficacy was more effective than the low theoretical fidelity intervention, especially for those with high attendance.

  7. An information theoretic approach to use high-fidelity codes to calibrate low-fidelity codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Allison, E-mail: lewis.allison10@gmail.com; Smith, Ralph; Williams, Brian

    For many simulation models, it can be prohibitively expensive or physically infeasible to obtain a complete set of experimental data to calibrate model parameters. In such cases, one can alternatively employ validated higher-fidelity codes to generate simulated data, which can be used to calibrate the lower-fidelity code. In this paper, we employ an information-theoretic framework to determine the reduction in parameter uncertainty that is obtained by evaluating the high-fidelity code at a specific set of design conditions. These conditions are chosen sequentially, based on the amount of information that they contribute to the low-fidelity model parameters. The goal is tomore » employ Bayesian experimental design techniques to minimize the number of high-fidelity code evaluations required to accurately calibrate the low-fidelity model. We illustrate the performance of this framework using heat and diffusion examples, a 1-D kinetic neutron diffusion equation, and a particle transport model, and include initial results from the integration of the high-fidelity thermal-hydraulics code Hydra-TH with a low-fidelity exponential model for the friction correlation factor.« less

  8. Demystifying the Complexities of Gravity Wave Dynamics in the Middle Atmosphere: a Roadmap to Improved Weather Forecasts through High-Fidelity Modeling

    NASA Astrophysics Data System (ADS)

    Mixa, T.; Fritts, D. C.; Bossert, K.; Laughman, B.; Wang, L.; Lund, T.; Kantha, L. H.

    2017-12-01

    Gravity waves play a profound role in the mixing of the atmosphere, transporting vast amounts of momentum and energy among different altitudes as they propagate vertically. Above 60km in the middle atmosphere, high wave amplitudes enable a series of complex, nonlinear interactions with the background environment that produce highly-localized wind and temperature variations which alter the layering structure of the atmosphere. These small-scale interactions account for a significant portion of energy transport in the middle atmosphere, but they are difficult to characterize, occurring at spatial scales that are both challenging to observe with ground instruments and prohibitively small to include in weather forecasting models. Using high fidelity numerical simulations, these nuanced wave interactions are analyzed to better our understanding of these dynamics and improve the accuracy of long-term weather forecasting.

  9. Fidelity to the housing first model and effectiveness of permanent supported housing programs in California.

    PubMed

    Gilmer, Todd P; Stefancic, Ana; Katz, Marian L; Sklar, Marisa; Tsemberis, Sam; Palinkas, Lawrence A

    2014-11-01

    Permanent supported housing programs are being implemented throughout the United States. This study examined the relationship between fidelity to the Housing First model and residential outcomes among clients of full service partnerships (FSPs) in California. This study had a mixed-methods design. Quantitative administrative and survey data were used to describe FSP practices and to examine the association between fidelity to Housing First and residential outcomes in the year before and after enrollment of 6,584 FSP clients in 86 programs. Focus groups at 20 FSPs provided qualitative data to enhance the understanding of these findings with actual accounts of housing-related experiences in high- and low-fidelity programs. Prior to enrollment, the mean days of homelessness were greater at high- versus low-fidelity (101 versus 46 days) FSPs. After adjustment for individual characteristics, the analysis found that days spent homeless after enrollment declined by 87 at high-fidelity programs and by 34 at low-fidelity programs. After adjustment for days spent homeless before enrollment, days spent homeless after enrollment declined by 63 at high-fidelity programs and by 53 at low-fidelity programs. After enrollment, clients at high-fidelity programs spent more than 60 additional days in apartments than clients at low-facility programs. Differences were found between high- and low-fidelity FSPs in client choice in housing and how much clients' goals were considered in housing placement. Programs with greater fidelity to the Housing First model enrolled clients with longer histories of homelessness and placed most of them in apartments.

  10. Real-time fetal ECG system design using embedded microprocessors

    NASA Astrophysics Data System (ADS)

    Meyer-Baese, Uwe; Muddu, Harikrishna; Schinhaerl, Sebastian; Kumm, Martin; Zipf, Peter

    2016-05-01

    The emphasis of this project lies in the development and evaluation of new robust and high fidelity fetal electrocardiogram (FECG) systems to determine the fetal heart rate (FHR). Recently several powerful algorithms have been suggested to improve the FECG fidelity. Until now it is unknown if these algorithms allow a real-time processing, can be used in mobile systems (low power), and which algorithm produces the best error rate for a given system configuration. In this work we have developed high performance, low power microprocessor-based biomedical systems that allow a fair comparison of proposed, state-of-the-art FECG algorithms. We will evaluate different soft-core microprocessors and compare these solutions to other commercial off-the-shelf (COTS) hardcore solutions in terms of price, size, power, and speed.

  11. The Validity and Incremental Validity of Knowledge Tests, Low-Fidelity Simulations, and High-Fidelity Simulations for Predicting Job Performance in Advanced-Level High-Stakes Selection

    ERIC Educational Resources Information Center

    Lievens, Filip; Patterson, Fiona

    2011-01-01

    In high-stakes selection among candidates with considerable domain-specific knowledge and experience, investigations of whether high-fidelity simulations (assessment centers; ACs) have incremental validity over low-fidelity simulations (situational judgment tests; SJTs) are lacking. Therefore, this article integrates research on the validity of…

  12. A multi-fidelity framework for physics based rotor blade simulation and optimization

    NASA Astrophysics Data System (ADS)

    Collins, Kyle Brian

    New helicopter rotor designs are desired that offer increased efficiency, reduced vibration, and reduced noise. Rotor Designers in industry need methods that allow them to use the most accurate simulation tools available to search for these optimal designs. Computer based rotor analysis and optimization have been advanced by the development of industry standard codes known as "comprehensive" rotorcraft analysis tools. These tools typically use table look-up aerodynamics, simplified inflow models and perform aeroelastic analysis using Computational Structural Dynamics (CSD). Due to the simplified aerodynamics, most design studies are performed varying structural related design variables like sectional mass and stiffness. The optimization of shape related variables in forward flight using these tools is complicated and results are viewed with skepticism because rotor blade loads are not accurately predicted. The most accurate methods of rotor simulation utilize Computational Fluid Dynamics (CFD) but have historically been considered too computationally intensive to be used in computer based optimization, where numerous simulations are required. An approach is needed where high fidelity CFD rotor analysis can be utilized in a shape variable optimization problem with multiple objectives. Any approach should be capable of working in forward flight in addition to hover. An alternative is proposed and founded on the idea that efficient hybrid CFD methods of rotor analysis are ready to be used in preliminary design. In addition, the proposed approach recognizes the usefulness of lower fidelity physics based analysis and surrogate modeling. Together, they are used with high fidelity analysis in an intelligent process of surrogate model building of parameters in the high fidelity domain. Closing the loop between high and low fidelity analysis is a key aspect of the proposed approach. This is done by using information from higher fidelity analysis to improve predictions made with lower fidelity models. This thesis documents the development of automated low and high fidelity physics based rotor simulation frameworks. The low fidelity framework uses a comprehensive code with simplified aerodynamics. The high fidelity model uses a parallel processor capable CFD/CSD methodology. Both low and high fidelity frameworks include an aeroacoustic simulation for prediction of noise. A synergistic process is developed that uses both the low and high fidelity frameworks together to build approximate models of important high fidelity metrics as functions of certain design variables. To test the process, a 4-bladed hingeless rotor model is used as a baseline. The design variables investigated include tip geometry and spanwise twist distribution. Approximation models are built for metrics related to rotor efficiency and vibration using the results from 60+ high fidelity (CFD/CSD) experiments and 400+ low fidelity experiments. Optimization using the approximation models found the Pareto Frontier anchor points, or the design having maximum rotor efficiency and the design having minimum vibration. Various Pareto generation methods are used to find designs on the frontier between these two anchor designs. When tested in the high fidelity framework, the Pareto anchor designs are shown to be very good designs when compared with other designs from the high fidelity database. This provides evidence that the process proposed has merit. Ultimately, this process can be utilized by industry rotor designers with their existing tools to bring high fidelity analysis into the preliminary design stage of rotors. In conclusion, the methods developed and documented in this thesis have made several novel contributions. First, an automated high fidelity CFD based forward flight simulation framework has been built for use in preliminary design optimization. The framework was built around an integrated, parallel processor capable CFD/CSD/AA process. Second, a novel method of building approximate models of high fidelity parameters has been developed. The method uses a combination of low and high fidelity results and combines Design of Experiments, statistical effects analysis, and aspects of approximation model management. And third, the determination of rotor blade shape variables through optimization using CFD based analysis in forward flight has been performed. This was done using the high fidelity CFD/CSD/AA framework and method mentioned above. While the low and high fidelity predictions methods used in the work still have inaccuracies that can affect the absolute levels of the results, a framework has been successfully developed and demonstrated that allows for an efficient process to improve rotor blade designs in terms of a selected choice of objective function(s). Using engineering judgment, this methodology could be applied today to investigate opportunities to improve existing designs. With improvements in the low and high fidelity prediction components that will certainly occur, this framework could become a powerful tool for future rotorcraft design work. (Abstract shortened by UMI.)

  13. Soft-lithography fabrication of microfluidic features using thiol-ene formulations.

    PubMed

    Ashley, John F; Cramer, Neil B; Davis, Robert H; Bowman, Christopher N

    2011-08-21

    In this work, a novel thiol-ene based photopolymerizable resin formulation was shown to exhibit highly desirable characteristics, such as low cure time and the ability to overcome oxygen inhibition, for the photolithographic fabrication of microfluidic devices. The feature fidelity, as well as various aspects of the feature shape and quality, were assessed as functions of various resin attributes, particularly the exposure conditions, initiator concentration and inhibitor to initiator ratio. An optical technique was utilized to evaluate the feature fidelity as well as the feature shape and quality. These results were used to optimize the thiol-ene resin formulation to produce high fidelity, high aspect ratio features without significant reductions in feature quality. For structures with aspect ratios below 2, little difference (<3%) in feature quality was observed between thiol-ene and acrylate based formulations. However, at higher aspect ratios, the thiol-ene resin exhibited significantly improved feature quality. At an aspect ratio of 8, raised feature quality for the thiol-ene resin was dramatically better than that achieved by using the acrylate resin. The use of the thiol-ene based resin enabled fabrication of a pinched-flow microfluidic device that has complex channel geometry, small (50 μm) channel dimensions, and high aspect ratio (14) features. This journal is © The Royal Society of Chemistry 2011

  14. Argonne News Brief: Making Sense of Noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Argonne Leadership Computing Facility at Argonne National Laboratory helped Joe Nichols, of the University of Minnesota, to create high fidelity simulations of jet turbulence to determine how and where noise is produced. The results may lead to novel engineering designs that reduce noise over commercial flight paths and on aircraft carrier decks.

  15. Automatic 3D high-fidelity traffic interchange modeling using 2D road GIS data

    NASA Astrophysics Data System (ADS)

    Wang, Jie; Shen, Yuzhong

    2011-03-01

    3D road models are widely used in many computer applications such as racing games and driving simulations. However, almost all high-fidelity 3D road models were generated manually by professional artists at the expense of intensive labor. There are very few existing methods for automatically generating 3D high-fidelity road networks, especially for those existing in the real world. Real road network contains various elements such as road segments, road intersections and traffic interchanges. Among them, traffic interchanges present the most challenges to model due to their complexity and the lack of height information (vertical position) of traffic interchanges in existing road GIS data. This paper proposes a novel approach that can automatically produce 3D high-fidelity road network models, including traffic interchange models, from real 2D road GIS data that mainly contain road centerline information. The proposed method consists of several steps. The raw road GIS data are first preprocessed to extract road network topology, merge redundant links, and classify road types. Then overlapped points in the interchanges are detected and their elevations are determined based on a set of level estimation rules. Parametric representations of the road centerlines are then generated through link segmentation and fitting, and they have the advantages of arbitrary levels of detail with reduced memory usage. Finally a set of civil engineering rules for road design (e.g., cross slope, superelevation) are selected and used to generate realistic road surfaces. In addition to traffic interchange modeling, the proposed method also applies to other more general road elements. Preliminary results show that the proposed method is highly effective and useful in many applications.

  16. High-Fidelity Simulations of Electromagnetic Propagation and RF Communication Systems

    DTIC Science & Technology

    2017-05-01

    addition to high -fidelity RF propagation modeling, lower-fidelity mod- els, which are less computationally burdensome, are available via a C++ API...expensive to perform, requiring roughly one hour of computer time with 36 available cores and ray tracing per- formed by a single high -end GPU...ER D C TR -1 7- 2 Military Engineering Applied Research High -Fidelity Simulations of Electromagnetic Propagation and RF Communication

  17. Implementation fidelity trajectories of a health promotion program in multidisciplinary settings: managing tensions in rehabilitation care.

    PubMed

    Hoekstra, Femke; van Offenbeek, Marjolein A G; Dekker, Rienk; Hettinga, Florentina J; Hoekstra, Trynke; van der Woude, Lucas H V; van der Schans, Cees P

    2017-12-01

    Although the importance of evaluating implementation fidelity is acknowledged, little is known about heterogeneity in fidelity over time. This study aims to generate insight into the heterogeneity in implementation fidelity trajectories of a health promotion program in multidisciplinary settings and the relationship with changes in patients' health behavior. This study used longitudinal data from the nationwide implementation of an evidence-informed physical activity promotion program in Dutch rehabilitation care. Fidelity scores were calculated based on annual surveys filled in by involved professionals (n = ± 70). Higher fidelity scores indicate a more complete implementation of the program's core components. A hierarchical cluster analysis was conducted on the implementation fidelity scores of 17 organizations at three different time points. Quantitative and qualitative data were used to explore organizational and professional differences between identified trajectories. Regression analyses were conducted to determine differences in patient outcomes. Three trajectories were identified as the following: 'stable high fidelity' (n = 9), 'moderate and improving fidelity' (n = 6), and 'unstable fidelity' (n = 2). The stable high fidelity organizations were generally smaller, started earlier, and implemented the program in a more structured way compared to moderate and improving fidelity organizations. At the implementation period's start and end, support from physicians and physiotherapists, professionals' appreciation, and program compatibility were rated more positively by professionals working in stable high fidelity organizations as compared to the moderate and improving fidelity organizations (p < .05). Qualitative data showed that the stable high fidelity organizations had often an explicit vision and strategy about the implementation of the program. Intriguingly, the trajectories were not associated with patients' self-reported physical activity outcomes (adjusted model β = - 651.6, t(613) = - 1032, p = .303). Differences in organizational-level implementation fidelity trajectories did not result in outcome differences at patient-level. This suggests that an effective implementation fidelity trajectory is contingent on the local organization's conditions. More specifically, achieving stable high implementation fidelity required the management of tensions: realizing a localized change vision, while safeguarding the program's standardized core components and engaging the scarce physicians throughout the process. When scaling up evidence-informed health promotion programs, we propose to tailor the management of implementation tensions to local organizations' starting position, size, and circumstances. The Netherlands National Trial Register NTR3961 . Registered 18 April 2013.

  18. The Need for High Fidelity Lunar Regolith Simulants

    NASA Technical Reports Server (NTRS)

    Gaier, James R.

    2007-01-01

    The case is made for the need to have high fidelity lunar regolith simulants to verify the performance of structures and mechanisms to be used on the lunar surface. Minor constituents will in some cases have major consequences. Small amounts of sulfur in the regolith can poison catalysts, and metallic iron on the surface of nano-sized dust particles may cause a dramatic increase in its toxicity. So the definition of a high fidelity simulant is application dependent. For example, in situ resource utilization will require high fidelity in chemistry, meaning careful attention to the minor components and phases; but some other applications, such as the abrasive effects on suit fabrics, might be relatively insensitive to minor component chemistry. The lunar environment itself will change the surface chemistry of the simulant, so to have a high fidelity simulant at must be used in a high fidelity simulated environment to get a high fidelity simulation. Research must be conducted to determine how sensitive technologies will be to minor components and environmental factors before they can be dismissed as unimportant.

  19. The Effect of Tow Shearing on Reinforcement Positional Fidelity in the Manufacture of a Continuous Fiber Reinforced Thermoplastic Matrix Composite via Pultrusion-Like Processing of Commingled Feedstock

    NASA Astrophysics Data System (ADS)

    Warlick, Kent M.

    While the addition of short fiber to 3D printed articles has increased structural performance, ultimate gains will only be realized through the introduction of continuous reinforcement placed along pre-planned load paths. Most additive manufacturing research focusing on the addition of continuous reinforcement has revolved around utilization of a prefrabricated composite filament or a fiber and matrix mixed within a hot end prior to deposition on a printing surface such that conventional extrusion based FDM can be applied. Although stronger 3D printed parts can be made in this manner, high quality homogenous composites are not possible due to fiber dominated regions, matrix dominated regions, and voids present between adjacent filaments. Conventional composite manufacturing processes are much better at creating homogeneous composites; however, the layer by layer approach in which they are made is inhibiting the alignment of reinforcement with loads. Automated Fiber Placement techniques utilize in plane bending deformation of the tow to facilitate tow steering. Due to buckling fibers on the inner radius of curves, manufacturers recommend a minimum curvature for path placement with this technique. A method called continuous tow shearing has shown promise to enable the placement of tows in complex patterns without tow buckling, spreading, and separation inherent in conventional forms of automated reinforcement positioning. The current work employs fused deposition modeling hardware and the continuous tow shearing technique to manufacture high quality fiber reinforced composites with high positional fidelity, varying continuous reinforcement orientations within a layer, and plastic elements incorporated enabling the ultimate gains in structural performance possible. A mechanical system combining concepts of additive manufacturing with fiber placement via filament winding was developed. Paths with and without tension inherent in filament winding were analyzed through microscopy in order to examine best and worst case scenarios. High quality fiber reinforced composite materials, in terms of low void content, high fiber volume fractions and homogeneity in microstructure, were manufactured in both of these scenarios. In order to improve fidelity and quality in fiber path transition regions, a forced air cooling manifold was designed, printed, and implemented into the current system. To better understand the composite performance that results from varying pertinent manufacturing parameters, the effect of feed rate, hot end temperature, forced air cooling, and deposition surface (polypropylene and previously deposited glass polypropylene commingled tow) on interply performance, microstructure, and positional fidelity were analyzed. Interply performance, in terms of average maximum load and average peel strength, was quantified through a t-peel test of the bonding quality between two surfaces. With use of forced air cooling, minor decreases in average peel strength were present due to a reduction in tow deposition temperature which was found to be the variable most indicative of performance. Average maximum load was comparable between the forced air cooled and non-air cooled samples. Microstructure was evaluated through characterization of composite area, void content, and flash percentage. Low void contents mostly between five to seven percent were attained. Further reduction of this void content to two percent is possible through higher processing temperatures; however, reduced composite area, low average peel strength performance, and the presence of smoke during manufacturing implied thermal degradation of the polypropylene matrix occurred in these samples with higher processing temperatures. Positional fidelity was measured through calculations of shear angle, shift width, and error of a predefined path. While positional fidelity variation was low with a polypropylene deposition surface, forced air cooling is necessary to achieve fidelity on top of an already deposited tow surface as evident by the fifty-six percent reduction in error tolerance profile achieved. Lastly, proof of concept articles with unique fiber paths and neat plastic elements incorporated were produced to demonstrate fiber placement along pre-planned load paths and the ability to achieve greater structural efficiency through the use of less material. The results show that high positional fidelity and high quality composites can be produced through the use of the tow shearing technique implemented in the developed mechanical system. The implementation of forced air cooling was critical in achieving fidelity and quality in transition regions. Alignment of continuous reinforcement with pre-planned load paths was demonstrated in the proof of concept article with varying fiber orientations within a layer. Combining fused deposition modeling of plastic with the placement of continuous reinforcement enabled a honeycomb composite to be produced with higher specific properties than traditional composites. Thus, the current system demonstrated a greater capability of achieving ultimate gains in structural performance than previously possible.

  20. Numerics and subgrid-scale modeling in large eddy simulations of stratocumulus clouds.

    PubMed

    Pressel, Kyle G; Mishra, Siddhartha; Schneider, Tapio; Kaul, Colleen M; Tan, Zhihong

    2017-06-01

    Stratocumulus clouds are the most common type of boundary layer cloud; their radiative effects strongly modulate climate. Large eddy simulations (LES) of stratocumulus clouds often struggle to maintain fidelity to observations because of the sharp gradients occurring at the entrainment interfacial layer at the cloud top. The challenge posed to LES by stratocumulus clouds is evident in the wide range of solutions found in the LES intercomparison based on the DYCOMS-II field campaign, where simulated liquid water paths for identical initial and boundary conditions varied by a factor of nearly 12. Here we revisit the DYCOMS-II RF01 case and show that the wide range of previous LES results can be realized in a single LES code by varying only the numerical treatment of the equations of motion and the nature of subgrid-scale (SGS) closures. The simulations that maintain the greatest fidelity to DYCOMS-II observations are identified. The results show that using weighted essentially non-oscillatory (WENO) numerics for all resolved advective terms and no explicit SGS closure consistently produces the highest-fidelity simulations. This suggests that the numerical dissipation inherent in WENO schemes functions as a high-quality, implicit SGS closure for this stratocumulus case. Conversely, using oscillatory centered difference numerical schemes for momentum advection, WENO numerics for scalars, and explicitly modeled SGS fluxes consistently produces the lowest-fidelity simulations. We attribute this to the production of anomalously large SGS fluxes near the cloud tops through the interaction of numerical error in the momentum field with the scalar SGS model.

  1. The implications of variable remigration intervals for the assessment of population size in marine turtles.

    PubMed

    Hays, G C

    2000-09-21

    Sea turtles nest on sandy beaches and tend to show high fidelity to specific nesting areas, but, despite this fidelity, the inter-annual variation in nesting numbers may be large. This variation may reflect the fact that turtles do not usually nest in consecutive years. Here, theoretical models are developed in which the interval between successive nesting years (the remigration interval) reflects conditions encountered on the feeding grounds, with good feeding years leading to a reduction in the remigration interval and vice versa. These simple models produce high levels of inter-annual variation in nesting numbers with, on occasion, almost no turtles nesting in some years even when the population is large and stable. The implications for assessing the size of sea turtle populations are considered. Copyright 2000 Academic Press.

  2. Freeform fabrication of tissue-simulating phantom for potential use of surgical planning in conjoined twins separation surgery.

    PubMed

    Shen, Shuwei; Wang, Haili; Xue, Yue; Yuan, Li; Zhou, Ximing; Zhao, Zuhua; Dong, Erbao; Liu, Bin; Liu, Wendong; Cromeens, Barrett; Adler, Brent; Besner, Gail; Xu, Ronald X

    2017-09-08

    Preoperative assessment of tissue anatomy and accurate surgical planning is crucial in conjoined twin separation surgery. We developed a new method that combines three-dimensional (3D) printing, assembling, and casting to produce anatomic models of high fidelity for surgical planning. The related anatomic features of the conjoined twins were captured by computed tomography (CT), classified as five organ groups, and reconstructed as five computer models. Among these organ groups, the skeleton was produced by fused deposition modeling (FDM) using acrylonitrile-butadiene-styrene. For the other four organ groups, shell molds were prepared by FDM and cast with silica gel to simulate soft tissues, with contrast enhancement pigments added to simulate different CT and visual contrasts. The produced models were assembled, positioned firmly within a 3D printed shell mold simulating the skin boundary, and cast with transparent silica gel. The produced phantom was subject to further CT scan in comparison with that of the patient data for fidelity evaluation. Further data analysis showed that the produced model reassembled the geometric features of the original CT data with an overall mean deviation of less than 2 mm, indicating the clinical potential to use this method for surgical planning in conjoined twin separation surgery.

  3. Performance Characteristics For The Orbiter Camera Payload System's Large Format Camera (LFC)

    NASA Astrophysics Data System (ADS)

    MoIIberg, Bernard H.

    1981-11-01

    The Orbiter Camera Payload System, the OCPS, is an integrated photographic system which is carried into Earth orbit as a payload in the Shuttle Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC) which is a precision wide-angle cartographic instrument that is capable of produc-ing high resolution stereophotography of great geometric fidelity in multiple base to height ratios. The primary design objective for the LFC was to maximize all system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment.

  4. Forgetting the Once-Seen Face: Estimating the Strength of an Eyewitness's Memory Representation

    ERIC Educational Resources Information Center

    Deffenbacher, Kenneth A.; Bornstein, Brian H.; McGorty, E. Kiernan; Penrod, Steven D.

    2008-01-01

    The fidelity of an eyewitness's memory representation is an issue of paramount forensic concern. Psychological science has been unable to offer more than vague generalities concerning the relation of retention interval to memory trace strength for the once-seen face. A meta-analysis of 53 facial memory studies produced a highly reliable…

  5. Simple proof of the quantum benchmark fidelity for continuous-variable quantum devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Namiki, Ryo

    2011-04-15

    An experimental success criterion for continuous-variable quantum teleportation and memory is to surpass the limit of the average fidelity achieved by classical measure-and-prepare schemes with respect to a Gaussian-distributed set of coherent states. We present an alternative proof of the classical limit based on the familiar notions of state-channel duality and partial transposition. The present method enables us to produce a quantum-domain criterion associated with a given set of measured fidelities.

  6. Rapid prototyping in orthopaedic surgery: a user's guide.

    PubMed

    Frame, Mark; Huntley, James S

    2012-01-01

    Rapid prototyping (RP) is applicable to orthopaedic problems involving three dimensions, particularly fractures, deformities, and reconstruction. In the past, RP has been hampered by cost and difficulties accessing the appropriate expertise. Here we outline the history of rapid prototyping and furthermore a process using open-source software to produce a high fidelity physical model from CT data. This greatly mitigates the expense associated with the technique, allowing surgeons to produce precise models for preoperative planning and procedure rehearsal. We describe the method with an illustrative case.

  7. Replicating an Intervention: The Tension between Fidelity and Adaptation

    ERIC Educational Resources Information Center

    Morrison, Diane M.; Hoppe, Marilyn J.; Gillmore, Mary Rogers; Kluver, Carisa; Higa, Darrel; Wells, Elizabeth A.

    2009-01-01

    Increased awareness of the importance of tailoring interventions to participants' cultures has focused attention on the limited generalizability of a single test of an intervention to determine efficacy. Adaptation is often necessary to replicate interventions across cultures. This produces a tension between fidelity to the original intervention…

  8. A randomized controlled study of manikin simulator fidelity on neonatal resuscitation program learning outcomes.

    PubMed

    Curran, Vernon; Fleet, Lisa; White, Susan; Bessell, Clare; Deshpandey, Akhil; Drover, Anne; Hayward, Mark; Valcour, James

    2015-03-01

    The neonatal resuscitation program (NRP) has been developed to educate physicians and other health care providers about newborn resuscitation and has been shown to improve neonatal resuscitation skills. Simulation-based training is recommended as an effective modality for instructing neonatal resuscitation and both low and high-fidelity manikin simulators are used. There is limited research that has compared the effect of low and high-fidelity manikin simulators for NRP learning outcomes, and more specifically on teamwork performance and confidence. The purpose of this study was to examine the effect of using low versus high-fidelity manikin simulators in NRP instruction. A randomized posttest-only control group study design was conducted. Third year undergraduate medical students participated in NRP instruction and were assigned to an experimental group (high-fidelity manikin simulator) or control group (low-fidelity manikin simulator). Integrated skills station (megacode) performance, participant satisfaction, confidence and teamwork behaviour scores were compared between the study groups. Participants in the high-fidelity manikin simulator instructional group reported significantly higher total scores in overall satisfaction (p = 0.001) and confidence (p = 0.001). There were no significant differences in teamwork behaviour scores, as observed by two independent raters, nor differences on mandatory integrated skills station performance items at the p < 0.05 level. Medical students' reported greater satisfaction and confidence with high-fidelity manikin simulators, but did not demonstrate overall significantly improved teamwork or integrated skills station performance. Low and high-fidelity manikin simulators facilitate similar levels of objectively measured NRP outcomes for integrated skills station and teamwork performance.

  9. The Project Towards No Drug Abuse (TND) Dissemination Trial: Implementation Fidelity and Immediate Outcomes

    PubMed Central

    Gunning, Melissa; Sun, Ping; Sussman, Steve

    2009-01-01

    One of the important research issues in the emerging area of research on dissemination of prevention programs relates to the type and extent of training needed by program providers to prepare them to implement effective programs with fidelity. The present paper describes the immediate outcomes of a dissemination and implementation trial of Project Toward No Drug Abuse, an evidence-based prevention program for high school students. A total of 65 high schools in 14 school districts across the USA were recruited and randomly assigned to one of three experimental conditions: comprehensive implementation support for teachers, regular workshop training only, or standard care control. The comprehensive intervention was comprised of on-site coaching, web-based support, and technical assistance, in addition to the regular workshop. Students (n=2,983) completed self-report surveys before and immediately after program implementation. Fidelity of implementation was assessed with a classroom observation procedure that focused on program process. Results indicated that relative to the controls, both intervention conditions produced effects on hypothesized program mediators, including greater gains in program-related knowledge; greater reductions in cigarette, marijuana and hard drug use intentions; and more positive changes in drug-related beliefs. There were stronger effects on implementation fidelity in the comprehensive, relative to the regular, training condition. However, seven of the ten immediate student outcome measures showed no significant differences between the two training conditions. The implications of these findings for dissemination research and practice are discussed. PMID:19757052

  10. The Project Towards No Drug Abuse (TND) dissemination trial: implementation fidelity and immediate outcomes.

    PubMed

    Rohrbach, Louise Ann; Gunning, Melissa; Sun, Ping; Sussman, Steve

    2010-03-01

    One of the important research issues in the emerging area of research on dissemination of prevention programs relates to the type and extent of training needed by program providers to prepare them to implement effective programs with fidelity. The present paper describes the immediate outcomes of a dissemination and implementation trial of Project Toward No Drug Abuse, an evidence-based prevention program for high school students. A total of 65 high schools in 14 school districts across the USA were recruited and randomly assigned to one of three experimental conditions: comprehensive implementation support for teachers, regular workshop training only, or standard care control. The comprehensive intervention was comprised of on-site coaching, web-based support, and technical assistance, in addition to the regular workshop. Students (n = 2,983) completed self-report surveys before and immediately after program implementation. Fidelity of implementation was assessed with a classroom observation procedure that focused on program process. Results indicated that relative to the controls, both intervention conditions produced effects on hypothesized program mediators, including greater gains in program-related knowledge; greater reductions in cigarette, marijuana and hard drug use intentions; and more positive changes in drug-related beliefs. There were stronger effects on implementation fidelity in the comprehensive, relative to the regular, training condition. However, seven of the ten immediate student outcome measures showed no significant differences between the two training conditions. The implications of these findings for dissemination research and practice are discussed.

  11. High Fidelity System Simulation of Multiple Components in Support of the UEET Program

    NASA Technical Reports Server (NTRS)

    Plybon, Ronald C.; VanDeWall, Allan; Sampath, Rajiv; Balasubramaniam, Mahadevan; Mallina, Ramakrishna; Irani, Rohinton

    2006-01-01

    The High Fidelity System Simulation effort has addressed various important objectives to enable additional capability within the NPSS framework. The scope emphasized High Pressure Turbine and High Pressure Compressor components. Initial effort was directed at developing and validating intermediate fidelity NPSS model using PD geometry and extended to high-fidelity NPSS model by overlaying detailed geometry to validate CFD against rig data. Both "feedforward" and feedback" approaches of analysis zooming was employed to enable system simulation capability in NPSS. These approaches have certain benefits and applicability in terms of specific applications "feedback" zooming allows the flow-up of information from high-fidelity analysis to be used to update the NPSS model results by forcing the NPSS solver to converge to high-fidelity analysis predictions. This apporach is effective in improving the accuracy of the NPSS model; however, it can only be used in circumstances where there is a clear physics-based strategy to flow up the high-fidelity analysis results to update the NPSS system model. "Feed-forward" zooming approach is more broadly useful in terms of enabling detailed analysis at early stages of design for a specified set of critical operating points and using these analysis results to drive design decisions early in the development process.

  12. Expressing Biomedical Ontologies in Natural Language for Expert Evaluation.

    PubMed

    Amith, Muhammad; Manion, Frank J; Harris, Marcelline R; Zhang, Yaoyun; Xu, Hua; Tao, Cui

    2017-01-01

    We report on a study of our custom Hootation software for the purposes of assessing its ability to produce clear and accurate natural language phrases from axioms embedded in three biomedical ontologies. Using multiple domain experts and three discrete rating scales, we evaluated the tool on clarity of the natural language produced, fidelity of the natural language produced from the ontology to the axiom, and the fidelity of the domain knowledge represented by the axioms. Results show that Hootation provided relatively clear natural language equivalents for a select set of OWL axioms, although the clarity of statements hinges on the accuracy and representation of axioms in the ontology.

  13. The Need for High Fidelity Lunar Regolith Simulants

    NASA Technical Reports Server (NTRS)

    Gaier, James R.

    2008-01-01

    The case is made for the need to have high fidelity lunar regolith simulants to verify the performance of structures, mechanisms, and processes to be used on the lunar surface. Minor constituents will in some cases have major consequences. Small amounts of sulfur in the regolith can poison catalysts, and metallic iron on the surface of nano-sized dust particles may cause a dramatic increase in its toxicity. So the definition of a high fidelity simulant is application-dependent. For example, in situ resource utilization will require high fidelity in chemistry, meaning careful attention to the minor components and phases; but some other applications, such as the abrasive effects on suit fabrics, might be relatively insensitive to minor component chemistry while abrasion of some metal components may be highly dependent on trace components. The lunar environment itself will change the surface chemistry of the simulant, so to have a high fidelity simulant it must be used in a high fidelity simulated environment to get an accurate simulation. Research must be conducted to determine how sensitive technologies will be to minor components and environmental factors before they can be dismissed as unimportant.

  14. Investigations of primary blast-induced traumatic brain injury

    NASA Astrophysics Data System (ADS)

    Sawyer, T. W.; Josey, T.; Wang, Y.; Villanueva, M.; Ritzel, D. V.; Nelson, P.; Lee, J. J.

    2018-01-01

    The development of an advanced blast simulator (ABS) has enabled the reproducible generation of single-pulse shock waves that simulate free-field blast with high fidelity. Studies with rodents in the ABS demonstrated the necessity of head restraint during head-only exposures. When the head was not restrained, violent global head motion was induced by pressures that would not produce similar movement of a target the size and mass of a human head. This scaling artefact produced changes in brain function that were reminiscent of traumatic brain injury (TBI) due to impact-acceleration effects. Restraint of the rodent head eliminated these, but still produced subtle changes in brain biochemistry, showing that blast-induced pressure waves do cause brain deficits. Further experiments were carried out with rat brain cell aggregate cultures that enabled the conduct of studies without the gross movement encountered when using rodents. The suspension nature of this model was also exploited to minimize the boundary effects that complicate the interpretation of primary blast studies using surface cultures. Using this system, brain tissue was found not only to be sensitive to pressure changes, but also able to discriminate between the highly defined single-pulse shock waves produced by underwater blast and the complex pressure history exposures experienced by aggregates encased within a sphere and subjected to simulated air blast. The nature of blast-induced primary TBI requires a multidisciplinary research approach that addresses the fidelity of the blast insult, its accurate measurement and characterization, as well as the limitations of the biological models used.

  15. Negative ion-driven associated particle neutron generator

    DOE PAGES

    Antolak, A. J.; Leung, K. N.; Morse, D. H.; ...

    2015-10-09

    We describe an associated particle neutron generator that employs a negative ion source to produce high neutron flux from a small source size. Furthermore, negative ions produced in an rf-driven plasma source are extracted through a small aperture to form a beam which bombards a positively biased, high voltage target electrode. Electrons co-extracted with the negative ions are removed by a permanent magnet electron filter. The use of negative ions enables high neutron output (100% atomic ion beam), high quality imaging (small neutron source size), and reliable operation (no high voltage breakdowns). Finally, the neutron generator can operate in eithermore » pulsed or continuous-wave (cw) mode and has been demonstrated to produce 10 6 D-D n/s (equivalent to similar to 10 8 D-T n/s) from a 1 mm-diameter neutron source size to facilitate high fidelity associated particle imaging.« less

  16. High Fidelity Modeling of Field Reversed Configuration (FRC) Thrusters

    DTIC Science & Technology

    2017-04-22

    signatures which can be used for direct, non -invasive, comparison with experimental diagnostics can be produced. This research will be directly... experimental campaign is critical to developing general design philosophies for low-power plasmoid formation, the complexity of non -linear plasma processes...advanced space propulsion. The work consists of numerical method development, physical model development, and systematic studies of the non -linear

  17. Development and analysis of a tick-borne encephalitis virus infectious clone using a novel and rapid strategy.

    PubMed

    Gritsun, T S; Gould, E A

    1998-12-01

    In less than 1 month we have constructed an infectious clone of attenuated tick-borne encephalitis virus (strain Vasilchenko) from 100 microl of unpurified virus suspension using long high fidelity PCR and a modified bacterial cloning system. Optimization of the 3' antisense primer concentration was essential to achieve PCR synthesis of an 11 kb cDNA copy of RNA from infectious virus. A novel system utilising two antisense primers, a 14-mer for reverse transcription and a 35-mer for long PCR, produced high yields of genomic length cDNA. Use of low copy number Able K cells and an incubation temperature of 28 degrees C increased the genetic stability of cloned cDNA. Clones containing 11 kb cDNA inserts produced colonies of reduced size, thus providing a positive selection system for full length clones. Sequencing of the infectious clone emphasised the improved fidelity of the method compared with conventional PCR and cloning methods. A simple and rapid strategy for genetic manipulation of the infectious clone is also described. These developments represent a significant advance in recombinant technology and should be applicable to positive stranded RNA viruses which cannot easily be purified or genetically manipulated.

  18. Fidelity of Majorana-based quantum operations

    NASA Astrophysics Data System (ADS)

    Tanhayi Ahari, Mostafa; Ortiz, Gerardo; Seradjeh, Babak

    2015-03-01

    It is well known that one-dimensional p-wave superconductor, the so-called Kitaev model, has topologically distinct phases that are distinguished by the presence of Majorana fermions. Owing to their topological protection, these Majorana fermions have emerged as candidates for fault-tolerant quantum computation. They furnish the operation of such a computation via processes that produce, braid, and annihilate them in pairs. In this work we study some of these processes from the dynamical perspective. In particular, we determine the fidelity of the Majorana fermions when they are produced or annihilated by tuning the system through the corresponding topological phase transition. For a simple linear protocol, we derive analytical expressions for fidelity and test various perturbative schemes. For more general protocols, we present exact numerics. Our results are relevant for the operation of Majorana-based quantum gates and quantum memories.

  19. High-Fidelity Piezoelectric Audio Device

    NASA Technical Reports Server (NTRS)

    Woodward, Stanley E.; Fox, Robert L.; Bryant, Robert G.

    2003-01-01

    ModalMax is a very innovative means of harnessing the vibration of a piezoelectric actuator to produce an energy efficient low-profile device with high-bandwidth high-fidelity audio response. The piezoelectric audio device outperforms many commercially available speakers made using speaker cones. The piezoelectric device weighs substantially less (4 g) than the speaker cones which use magnets (10 g). ModalMax devices have extreme fabrication simplicity. The entire audio device is fabricated by lamination. The simplicity of the design lends itself to lower cost. The piezoelectric audio device can be used without its acoustic chambers and thereby resulting in a very low thickness of 0.023 in. (0.58 mm). The piezoelectric audio device can be completely encapsulated, which makes it very attractive for use in wet environments. Encapsulation does not significantly alter the audio response. Its small size (see Figure 1) is applicable to many consumer electronic products, such as pagers, portable radios, headphones, laptop computers, computer monitors, toys, and electronic games. The audio device can also be used in automobile or aircraft sound systems.

  20. Measuring the Implementation Fidelity of the Response to Intervention Framework in Milwaukee Public Schools. Stated Briefly. REL 2017-192

    ERIC Educational Resources Information Center

    Ruffini, Steffen J.; Lindsay, Jim; Miskell, Ryan; Proger, Amy

    2016-01-01

    Regional Educational Laboratory Midwest assisted Milwaukee Public Schools in developing a fidelity monitoring system for measuring schools' progress in implementing Response to Intervention (RTI). The study examined the ratings produced by that system to determine the system's reliability, schools' progress in implementing RTI, and whether ratings…

  1. Concept Maps: A Tool to Prepare for High Fidelity Simulation in Nursing

    ERIC Educational Resources Information Center

    Daley, Barbara J.; Beman, Sarah Black; Morgan, Sarah; Kennedy, Linda; Sheriff, Mandy

    2017-01-01

    In this study, the use of concept mapping as a method to prepare for high fidelity simulated learning experiences was investigated. Fourth year baccalaureate nursing students were taught how to use concept maps as a way to prepare for high fidelity simulated nursing experiences. Students prepared concept maps for two simulated experiences…

  2. Rapid Prototyping in Orthopaedic Surgery: A User's Guide

    PubMed Central

    Frame, Mark; Huntley, James S.

    2012-01-01

    Rapid prototyping (RP) is applicable to orthopaedic problems involving three dimensions, particularly fractures, deformities, and reconstruction. In the past, RP has been hampered by cost and difficulties accessing the appropriate expertise. Here we outline the history of rapid prototyping and furthermore a process using open-source software to produce a high fidelity physical model from CT data. This greatly mitigates the expense associated with the technique, allowing surgeons to produce precise models for preoperative planning and procedure rehearsal. We describe the method with an illustrative case. PMID:22666160

  3. The effect of high-fidelity patient simulation on the critical thinking and clinical decision-making skills of new graduate nurses.

    PubMed

    Maneval, Rhonda; Fowler, Kimberly A; Kays, John A; Boyd, Tiffany M; Shuey, Jennifer; Harne-Britner, Sarah; Mastrine, Cynthia

    2012-03-01

    This study was conducted to determine whether the addition of high-fidelity patient simulation to new nurse orientation enhanced critical thinking and clinical decision-making skills. A pretest-posttest design was used to assess critical thinking and clinical decision-making skills in two groups of graduate nurses. Compared with the control group, the high-fidelity patient simulation group did not show significant improvement in mean critical thinking or clinical decision-making scores. When mean scores were analyzed, both groups showed an increase in critical thinking scores from pretest to posttest, with the high-fidelity patient simulation group showing greater gains in overall scores. However, neither group showed a statistically significant increase in mean test scores. The effect of high-fidelity patient simulation on critical thinking and clinical decision-making skills remains unclear. Copyright 2012, SLACK Incorporated.

  4. High-Fidelity Simulation for Neonatal Nursing Education: An Integrative Review of the Literature.

    PubMed

    Cooper, Allyson

    2015-01-01

    The lack of safe avenues to develop neonatal nursing competencies using human subjects leads to the notion that simulation education for neonatal nurses might be an ideal form of education. This integrative literature review compares traditional, teacher-centered education with high-fidelity simulation education for neonatal nurses. It examines the theoretical frameworks used in neonatal nursing education and outlines the advantages of this type of training, including improving communication and teamwork; providing an innovative pedagogical approach; and aiding in skill acquisition, confidence, and participant satisfaction. The importance of debriefing is also examined. High-fidelity simulation is not without disadvantages, including its significant cost, the time associated with training, the need for very complex technical equipment, and increased faculty resource requirements. Innovative uses of high-fidelity simulation in neonatal nursing education are suggested. High-fidelity simulation has great potential but requires additional research to fully prove its efficacy.

  5. Comparing synthetic imagery with real imagery for visible signature analysis: human observer results

    NASA Astrophysics Data System (ADS)

    Culpepper, Joanne B.; Richards, Noel; Madden, Christopher S.; Winter, Neal; Wheaton, Vivienne C.

    2017-10-01

    Synthetic imagery could potentially enhance visible signature analysis by providing a wider range of target images in differing environmental conditions than would be feasible to collect in field trials. Achieving this requires a method for generating synthetic imagery that is both verified to be realistic and produces the same visible signature analysis results as real images. Is target detectability as measured by image metrics the same for real images and synthetic images of the same scene? Is target detectability as measured by human observer trials the same for real images and synthetic images of the same scene, and how realistic do the synthetic images need to be? In this paper we present the results of a small scale exploratory study on the second question: a photosimulation experiment conducted using digital photographs and synthetic images generated of the same scene. Two sets of synthetic images were created: a high fidelity set created using an image generation tool, E-on Vue, and a low fidelity set created using a gaming engine, Unity 3D. The target detection results obtained using digital photographs were compared with those obtained using the two sets of synthetic images. There was a moderate correlation between the high fidelity synthetic image set and the real images in both the probability of correct detection (Pd: PCC = 0.58, SCC = 0.57) and mean search time (MST: PCC = 0.63, SCC = 0.61). There was no correlation between the low fidelity synthetic image set and the real images for the Pd, but a moderate correlation for MST (PCC = 0.67, SCC = 0.55).

  6. Foot-and-mouth disease virus type O specific mutations determine RNA-dependent RNA polymerase fidelity and virus attenuation.

    PubMed

    Li, Chen; Wang, Haiwei; Yuan, Tiangang; Woodman, Andrew; Yang, Decheng; Zhou, Guohui; Cameron, Craig E; Yu, Li

    2018-05-01

    Previous studies have shown that the FMDV Asia1/YS/CHA/05 high-fidelity mutagen-resistant variants are attenuated (Zeng et al., 2014). Here, we introduced the same single or multiple-amino-acid substitutions responsible for increased 3D pol fidelity of type Asia1 FMDV into the type O FMDV O/YS/CHA/05 infectious clone. The rescued viruses O-DA and O-DAMM are lower replication fidelity mutants and showed an attenuated phenotype. These results demonstrated that the same amino acid substitution of 3D pol in different serotypes of FMDV strains had different effects on viral fidelity. In addition, nucleoside analogues were used to select high-fidelity mutagen-resistant type O FMDV variants. The rescued mutagen-resistant type O FMDV high-fidelity variants exhibited significantly attenuated fitness and a reduced virulence phenotype. These results have important implications for understanding the molecular mechanism of FMDV evolution and pathogenicity, especially in developing a safer modified live-attenuated vaccine against FMDV. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Effect of hearing loss on semantic access by auditory and audiovisual speech in children.

    PubMed

    Jerger, Susan; Tye-Murray, Nancy; Damian, Markus F; Abdi, Hervé

    2013-01-01

    This research studied whether the mode of input (auditory versus audiovisual) influenced semantic access by speech in children with sensorineural hearing impairment (HI). Participants, 31 children with HI and 62 children with normal hearing (NH), were tested with the authors' new multimodal picture word task. Children were instructed to name pictures displayed on a monitor and ignore auditory or audiovisual speech distractors. The semantic content of the distractors was varied to be related versus unrelated to the pictures (e.g., picture distractor of dog-bear versus dog-cheese, respectively). In children with NH, picture-naming times were slower in the presence of semantically related distractors. This slowing, called semantic interference, is attributed to the meaning-related picture-distractor entries competing for selection and control of the response (the lexical selection by competition hypothesis). Recently, a modification of the lexical selection by competition hypothesis, called the competition threshold (CT) hypothesis, proposed that (1) the competition between the picture-distractor entries is determined by a threshold, and (2) distractors with experimentally reduced fidelity cannot reach the CT. Thus, semantically related distractors with reduced fidelity do not produce the normal interference effect, but instead no effect or semantic facilitation (faster picture naming times for semantically related versus unrelated distractors). Facilitation occurs because the activation level of the semantically related distractor with reduced fidelity (1) is not sufficient to exceed the CT and produce interference but (2) is sufficient to activate its concept, which then strengthens the activation of the picture and facilitates naming. This research investigated whether the proposals of the CT hypothesis generalize to the auditory domain, to the natural degradation of speech due to HI, and to participants who are children. Our multimodal picture word task allowed us to (1) quantify picture naming results in the presence of auditory speech distractors and (2) probe whether the addition of visual speech enriched the fidelity of the auditory input sufficiently to influence results. In the HI group, the auditory distractors produced no effect or a facilitative effect, in agreement with proposals of the CT hypothesis. In contrast, the audiovisual distractors produced the normal semantic interference effect. Results in the HI versus NH groups differed significantly for the auditory mode, but not for the audiovisual mode. This research indicates that the lower fidelity auditory speech associated with HI affects the normalcy of semantic access by children. Further, adding visual speech enriches the lower fidelity auditory input sufficiently to produce the semantic interference effect typical of children with NH.

  8. High-fidelity gates in quantum dot spin qubits

    PubMed Central

    Koh, Teck Seng; Coppersmith, S. N.; Friesen, Mark

    2013-01-01

    Several logical qubits and quantum gates have been proposed for semiconductor quantum dots controlled by voltages applied to top gates. The different schemes can be difficult to compare meaningfully. Here we develop a theoretical framework to evaluate disparate qubit-gating schemes on an equal footing. We apply the procedure to two types of double-dot qubits: the singlet–triplet and the semiconducting quantum dot hybrid qubit. We investigate three quantum gates that flip the qubit state: a DC pulsed gate, an AC gate based on logical qubit resonance, and a gate-like process known as stimulated Raman adiabatic passage. These gates are all mediated by an exchange interaction that is controlled experimentally using the interdot tunnel coupling g and the detuning ϵ, which sets the energy difference between the dots. Our procedure has two steps. First, we optimize the gate fidelity (f) for fixed g as a function of the other control parameters; this yields an that is universal for different types of gates. Next, we identify physical constraints on the control parameters; this yields an upper bound that is specific to the qubit-gate combination. We show that similar gate fidelities should be attainable for singlet-triplet qubits in isotopically purified Si, and for hybrid qubits in natural Si. Considerably lower fidelities are obtained for GaAs devices, due to the fluctuating magnetic fields ΔB produced by nuclear spins. PMID:24255105

  9. Cultured High-Fidelity Three-Dimensional Human Urogenital Tract Carcinomas and Process

    NASA Technical Reports Server (NTRS)

    Goodwin, Thomas J. (Inventor); Prewett, Tacey L. (Inventor); Spaulding, Glenn F. (Inventor); Wolf, David A. (Inventor)

    1998-01-01

    Artificial high-fidelity three-dimensional human urogenital tract carcinomas are propagated under in vitro-microgravity conditions from carcinoma cells. Artificial high-fidelity three-dimensional human urogenital tract carcinomas are also propagated from a coculture of normal urogenital tract cells inoculated with carcinoma cells. The microgravity culture conditions may be microgravity or simulated microgravity created in a horizontal rotating wall culture vessel.

  10. An Automatic Medium to High Fidelity Low-Thrust Global Trajectory Toolchain; EMTG-GMAT

    NASA Technical Reports Server (NTRS)

    Beeson, Ryne T.; Englander, Jacob A.; Hughes, Steven P.; Schadegg, Maximillian

    2015-01-01

    Solving the global optimization, low-thrust, multiple-flyby interplanetary trajectory problem with high-fidelity dynamical models requires an unreasonable amount of computational resources. A better approach, and one that is demonstrated in this paper, is a multi-step process whereby the solution of the aforementioned problem is solved at a lower-fidelity and this solution is used as an initial guess for a higher-fidelity solver. The framework presented in this work uses two tools developed by NASA Goddard Space Flight Center: the Evolutionary Mission Trajectory Generator (EMTG) and the General Mission Analysis Tool (GMAT). EMTG is a medium to medium-high fidelity low-thrust interplanetary global optimization solver, which now has the capability to automatically generate GMAT script files for seeding a high-fidelity solution using GMAT's local optimization capabilities. A discussion of the dynamical models as well as thruster and power modeling for both EMTG and GMAT are given in this paper. Current capabilities are demonstrated with examples that highlight the toolchains ability to efficiently solve the difficult low-thrust global optimization problem with little human intervention.

  11. Multi-fidelity methods for uncertainty quantification in transport problems

    NASA Astrophysics Data System (ADS)

    Tartakovsky, G.; Yang, X.; Tartakovsky, A. M.; Barajas-Solano, D. A.; Scheibe, T. D.; Dai, H.; Chen, X.

    2016-12-01

    We compare several multi-fidelity approaches for uncertainty quantification in flow and transport simulations that have a lower computational cost than the standard Monte Carlo method. The cost reduction is achieved by combining a small number of high-resolution (high-fidelity) simulations with a large number of low-resolution (low-fidelity) simulations. We propose a new method, a re-scaled Multi Level Monte Carlo (rMLMC) method. The rMLMC is based on the idea that the statistics of quantities of interest depends on scale/resolution. We compare rMLMC with existing multi-fidelity methods such as Multi Level Monte Carlo (MLMC) and reduced basis methods and discuss advantages of each approach.

  12. High versus Low Theoretical Fidelity Pedometer Intervention Using Social-Cognitive Theory on Steps and Self-Efficacy

    ERIC Educational Resources Information Center

    Raedeke, Thomas D.; Dlugonski, Deirdre

    2017-01-01

    Purpose: This study was designed to compare a low versus high theoretical fidelity pedometer intervention applying social-cognitive theory on step counts and self-efficacy. Method: Fifty-six public university employees participated in a 10-week randomized controlled trial with 2 conditions that varied in theoretical fidelity. Participants in the…

  13. Morphing Wings: A Study Using High-Fidelity Aerodynamic Shape Optimization

    NASA Astrophysics Data System (ADS)

    Curiale, Nathanael J.

    With the aviation industry under pressure to reduce fuel consumption, morphing wings have the capacity to improve aircraft performance, thereby making a significant contribution to reversing climate change. Through high-fidelity aerodynamic shape optimization, various forms of morphing wings are assessed for a hypothetical regional-class aircraft. The framework used solves the Reynolds-averaged Navier-Stokes equations and utilizes a gradient-based optimization algorithm. Baseline geometries are developed through multipoint optimization, where the average drag coefficient is minimized over a range of flight conditions with additional dive constraints. Morphing optimizations are then performed, beginning with these baseline shapes. Five distinct types of morphing are investigated and compared. Overall, a theoretical fully adaptable wing produces roughly a 2% improvement in average performance, whereas trailing-edge morphing with a 27-point multipoint baseline results in just over a 1% improvement in average performance. Trailing-edge morphing proves to be more beneficial than leading-edge morphing, upper-surface morphing, and a conventional flap.

  14. Self-stabilized narrow-bandwidth and high-fidelity entangled photons generated from cold atoms

    NASA Astrophysics Data System (ADS)

    Yu, Y. C.; Ding, D. S.; Dong, M. X.; Shi, S.; Zhang, W.; Shi, B. S.

    2018-04-01

    Entangled photon pairs are critically important in fundamental quantum mechanics research as well as in many areas within the field of quantum information, such as quantum communication, quantum computation, and quantum cryptography. Previous demonstrations of entangled photons based on atomic ensembles were achieved by using a reference laser to stabilize the phase of two spontaneous four-wave mixing paths. Here, we demonstrate a convenient and efficient scheme to generate polarization-entangled photons with a narrow bandwidth of 57.2 ±1.6 MHz and a high-fidelity of 96.3 ±0.8 % by using a phase self-stabilized multiplexing system formed by two beam displacers and two half-wave plates where the relative phase between the different signal paths can be eliminated completely. It is possible to stabilize an entangled photon pair for a long time with this system and produce all four Bell states, making this a vital step forward in the field of quantum information.

  15. Wind Farm Flow Modeling using an Input-Output Reduced-Order Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Annoni, Jennifer; Gebraad, Pieter; Seiler, Peter

    Wind turbines in a wind farm operate individually to maximize their own power regardless of the impact of aerodynamic interactions on neighboring turbines. There is the potential to increase power and reduce overall structural loads by properly coordinating turbines. To perform control design and analysis, a model needs to be of low computational cost, but retains the necessary dynamics seen in high-fidelity models. The objective of this work is to obtain a reduced-order model that represents the full-order flow computed using a high-fidelity model. A variety of methods, including proper orthogonal decomposition and dynamic mode decomposition, can be used tomore » extract the dominant flow structures and obtain a reduced-order model. In this paper, we combine proper orthogonal decomposition with a system identification technique to produce an input-output reduced-order model. This technique is used to construct a reduced-order model of the flow within a two-turbine array computed using a large-eddy simulation.« less

  16. Measurement and Prediction of the Thermomechanical Response of Shape Memory Alloy Hybrid Composite Beams

    NASA Technical Reports Server (NTRS)

    Davis, Brian; Turner, Travis L.; Seelecke, Stefan

    2008-01-01

    An experimental and numerical investigation into the static and dynamic responses of shape memory alloy hybrid composite (SMAHC) beams is performed to provide quantitative validation of a recently commercialized numerical analysis/design tool for SMAHC structures. The SMAHC beam specimens consist of a composite matrix with embedded pre-strained SMA actuators, which act against the mechanical boundaries of the structure when thermally activated to adaptively stiffen the structure. Numerical results are produced from the numerical model as implemented into the commercial finite element code ABAQUS. A rigorous experimental investigation is undertaken to acquire high fidelity measurements including infrared thermography and projection moire interferometry for full-field temperature and displacement measurements, respectively. High fidelity numerical results are also obtained from the numerical model and include measured parameters, such as geometric imperfection and thermal load. Excellent agreement is achieved between the predicted and measured results of the static and dynamic thermomechanical response, thereby providing quantitative validation of the numerical tool.

  17. Simulation in a dynamic prototyping environment: Petri nets or rules?

    NASA Technical Reports Server (NTRS)

    Moore, Loretta A.; Price, Shannon W.; Hale, Joseph P.

    1994-01-01

    An evaluation of a prototyped user interface is best supported by a simulation of the system. A simulation allows for dynamic evaluation of the interface rather than just a static evaluation of the screen's appearance. This allows potential users to evaluate both the look (in terms of the screen layout, color, objects, etc.) and feel (in terms of operations and actions which need to be performed) of a system's interface. Because of the need to provide dynamic evaluation of an interface, there must be support for producing active simulations. The high-fidelity training simulators are normally delivered too late to be effectively used in prototyping the displays. Therefore, it is important to build a low fidelity simulator, so that the iterative cycle of refining the human computer interface based upon a user's interactions can proceed early in software development.

  18. Simulation in a dynamic prototyping environment: Petri nets or rules?

    NASA Technical Reports Server (NTRS)

    Moore, Loretta A.; Price, Shannon; Hale, Joseph P.

    1994-01-01

    An evaluation of a prototyped user interface is best supported by a simulation of the system. A simulation allows for dynamic evaluation of the interface rather than just a static evaluation of the screen's appearance. This allows potential users to evaluate both the look (in terms of the screen layout, color, objects, etc.) and feel (in terms of operations and actions which need to be performed) of a system's interface. Because of the need to provide dynamic evaluation of an interface, there must be support for producing active simulations. The high-fidelity training simulators are delivered too late to be effectively used in prototyping the displays. Therefore, it is important to build a low fidelity simulator, so that the iterative cycle of refining the human computer interface based upon a user's interactions can proceed early in software development.

  19. Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source.

    PubMed

    Steidle, Jeffrey A; Fanto, Michael L; Preble, Stefan F; Tison, Christopher C; Howland, Gregory A; Wang, Zihao; Alsing, Paul M

    2017-04-04

    Silicon photonic chips have the potential to realize complex integrated quantum information processing circuits, including photon sources, qubit manipulation, and integrated single-photon detectors. Here, we present the key aspects of preparing and testing a silicon photonic quantum chip with an integrated photon source and two-photon interferometer. The most important aspect of an integrated quantum circuit is minimizing loss so that all of the generated photons are detected with the highest possible fidelity. Here, we describe how to perform low-loss edge coupling by using an ultra-high numerical aperture fiber to closely match the mode of the silicon waveguides. By using an optimized fusion splicing recipe, the UHNA fiber is seamlessly interfaced with a standard single-mode fiber. This low-loss coupling allows the measurement of high-fidelity photon production in an integrated silicon ring resonator and the subsequent two-photon interference of the produced photons in a closely integrated Mach-Zehnder interferometer. This paper describes the essential procedures for the preparation and characterization of high-performance and scalable silicon quantum photonic circuits.

  20. High-fidelity in vivo replication of DNA base shape mimics without Watson–Crick hydrogen bonds

    PubMed Central

    Delaney, James C.; Henderson, Paul T.; Helquist, Sandra A.; Morales, Juan C.; Essigmann, John M.; Kool, Eric T.

    2003-01-01

    We report studies testing the importance of Watson–Crick hydrogen bonding, base-pair geometry, and steric effects during DNA replication in living bacterial cells. Nonpolar DNA base shape mimics of thymine and adenine (abbreviated F and Q, respectively) were introduced into Escherichia coli by insertion into a phage genome followed by transfection of the vector into bacteria. Genetic assays showed that these two base mimics were bypassed with moderate to high efficiency in the cells and with very high efficiency under damage-response (SOS induction) conditions. Under both sets of conditions, the T-shape mimic (F) encoded genetic information in the bacteria as if it were thymine, directing incorporation of adenine opposite it with high fidelity. Similarly, the A mimic (Q) directed incorporation of thymine opposite itself with high fidelity. The data establish that Watson–Crick hydrogen bonding is not necessary for high-fidelity replication of a base pair in vivo. The results suggest that recognition of DNA base shape alone serves as the most powerful determinant of fidelity during transfer of genetic information in a living organism. PMID:12676985

  1. High Fidelity Simulation of Atomization in Diesel Engine Sprays

    DTIC Science & Technology

    2015-09-01

    ARL-RP-0555 ● SEP 2015 US Army Research Laboratory High Fidelity Simulation of Atomization in Diesel Engine Sprays by L Bravo...ARL-RP-0555 ● SEP 2015 US Army Research Laboratory High Fidelity Simulation of Atomization in Diesel Engine Sprays by L...Simulation of Atomization in Diesel Engine Sprays 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) L Bravo, CB Ivey, D

  2. Implementation Fidelity in Community-Based Interventions

    PubMed Central

    Breitenstein, Susan M.; Gross, Deborah; Garvey, Christine; Hill, Carri; Fogg, Louis; Resnick, Barbara

    2012-01-01

    Implementation fidelity is the degree to which an intervention is delivered as intended and is critical to successful translation of evidence-based interventions into practice. Diminished fidelity may be why interventions that work well in highly controlled trials may fail to yield the same outcomes when applied in real life contexts. The purpose of this paper is to define implementation fidelity and describe its importance for the larger science of implementation, discuss data collection methods and current efforts in measuring implementation fidelity in community-based prevention interventions, and present future research directions for measuring implementation fidelity that will advance implementation science. PMID:20198637

  3. NPSS Multidisciplinary Integration and Analysis

    NASA Technical Reports Server (NTRS)

    Hall, Edward J.; Rasche, Joseph; Simons, Todd A.; Hoyniak, Daniel

    2006-01-01

    The objective of this task was to enhance the capability of the Numerical Propulsion System Simulation (NPSS) by expanding its reach into the high-fidelity multidisciplinary analysis area. This task investigated numerical techniques to convert between cold static to hot running geometry of compressor blades. Numerical calculations of blade deformations were iteratively done with high fidelity flow simulations together with high fidelity structural analysis of the compressor blade. The flow simulations were performed with the Advanced Ducted Propfan Analysis (ADPAC) code, while structural analyses were performed with the ANSYS code. High fidelity analyses were used to evaluate the effects on performance of: variations in tip clearance, uncertainty in manufacturing tolerance, variable inlet guide vane scheduling, and the effects of rotational speed on the hot running geometry of the compressor blades.

  4. Generation and applications of an ultrahigh-fidelity four-photon Greenberger-Horne-Zeilinger state.

    PubMed

    Zhang, Chao; Huang, Yun-Feng; Zhang, Cheng-Jie; Wang, Jian; Liu, Bi-Heng; Li, Chuan-Feng; Guo, Guang-Can

    2016-11-28

    High-quality entangled photon pairs generated via spontaneous parametric down-conversion have made great contributions to the modern quantum information science and the fundamental tests of quantum mechanics. However, the quality of the entangled states decreases sharply when moving from biphoton to multiphoton experiments, mainly due to the lack of interactions between photons. Here, for the first time, we generate a four-photon Greenberger-Horne-Zeilinger state with a fidelity of 98%, which is even comparable to the best fidelity of biphoton entangled states. Thus, it enables us to demonstrate an ultrahigh-fidelity entanglement swapping-the key ingredient in various quantum information tasks. Our results push the fidelity of multiphoton entanglement generation to a new level and would be useful in some demanding tasks, e.g., we successfully demonstrate the genuine multipartite nonlocality of the observed state in the nonsignaling scenario by violating a novel Hardy-like inequality, which requires very high state-fidelity.

  5. Optimal control of universal quantum gates in a double quantum dot

    NASA Astrophysics Data System (ADS)

    Castelano, Leonardo K.; de Lima, Emanuel F.; Madureira, Justino R.; Degani, Marcos H.; Maialle, Marcelo Z.

    2018-06-01

    We theoretically investigate electron spin operations driven by applied electric fields in a semiconductor double quantum dot (DQD) formed in a nanowire with longitudinal potential modulated by local gating. We develop a model that describes the process of loading and unloading the DQD taking into account the overlap between the electron wave function and the leads. Such a model considers the spatial occupation and the spin Pauli blockade in a time-dependent fashion due to the highly mixed states driven by the external electric field. Moreover, we present a road map based on the quantum optimal control theory (QOCT) to find a specific electric field that performs two-qubit quantum gates on a faster timescale and with higher possible fidelity. By employing the QOCT, we demonstrate the possibility of performing within high efficiency a universal set of quantum gates {cnot, H, and T } , where cnot is the controlled-not gate, H is the Hadamard gate, and T is the π /8 gate, even in the presence of the loading/unloading process and charge noise effects. Furthermore, by varying the intensity of the applied magnetic field B , the optimized fidelity of the gates oscillates with a period inversely proportional to the gate operation time tf. This behavior can be useful to attain higher fidelity for fast gate operations (>1 GHz) by appropriately choosing B and tf to produce a maximum of the oscillation.

  6. Implementing a high-fidelity simulation program in a community college setting.

    PubMed

    Tuoriniemi, Pamela; Schott-Baer, Darlene

    2008-01-01

    Despite their relatively high cost, there is heightened interest by faculty in undergraduate nursing programs to implement high-fidelity simulation (HFS) programs. High-fidelity simulators are appealing because they allow students to experience high-risk, low-volume patient problems in a realistic setting. The decision to purchase a simulator is the first step in the process of implementing and maintaining an HFS lab. Knowledge, technical skill, commitment, and considerable time are needed to develop a successful program. The process, as experienced by one community college nursing program, is described.

  7. Teaching elliptical excision skills to novice medical students: a randomized controlled study comparing low- and high-fidelity bench models.

    PubMed

    Denadai, Rafael; Oshiiwa, Marie; Saad-Hossne, Rogério

    2014-03-01

    The search for alternative and effective forms of training simulation is needed due to ethical and medico-legal aspects involved in training surgical skills on living patients, human cadavers and living animals. To evaluate if the bench model fidelity interferes in the acquisition of elliptical excision skills by novice medical students. Forty novice medical students were randomly assigned to 5 practice conditions with instructor-directed elliptical excision skills' training (n = 8): didactic materials (control); organic bench model (low-fidelity); ethylene-vinyl acetate bench model (low-fidelity); chicken legs' skin bench model (high-fidelity); or pig foot skin bench model (high-fidelity). Pre- and post-tests were applied. Global rating scale, effect size, and self-perceived confidence based on Likert scale were used to evaluate all elliptical excision performances. The analysis showed that after training, the students practicing on bench models had better performance based on Global rating scale (all P < 0.0000) and felt more confident to perform elliptical excision skills (all P < 0.0000) when compared to the control. There was no significant difference (all P > 0.05) between the groups that trained on bench models. The magnitude of the effect (basic cutaneous surgery skills' training) was considered large (>0.80) in all measurements. The acquisition of elliptical excision skills after instructor-directed training on low-fidelity bench models was similar to the training on high-fidelity bench models; and there was a more substantial increase in elliptical excision performances of students that trained on all simulators compared to the learning on didactic materials.

  8. Electro-Optic Frequency Beam Splitters and Tritters for High-Fidelity Photonic Quantum Information Processing

    DOE PAGES

    Lu, Hsuan-Hao; Lukens, Joseph M.; Peters, Nicholas A.; ...

    2018-01-18

    In this paper, we report the experimental realization of high-fidelity photonic quantum gates for frequency-encoded qubits and qutrits based on electro-optic modulation and Fourier-transform pulse shaping. Our frequency version of the Hadamard gate offers near-unity fidelity (0.99998±0.00003), requires only a single microwave drive tone for near-ideal performance, functions across the entire C band (1530–1570 nm), and can operate concurrently on multiple qubits spaced as tightly as four frequency modes apart, with no observable degradation in the fidelity. For qutrits, we implement a 3×3 extension of the Hadamard gate: the balanced tritter. This tritter—the first ever demonstrated for frequency modes—attains fidelitymore » 0.9989±0.0004. Finally, these gates represent important building blocks toward scalable, high-fidelity quantum information processing based on frequency encoding.« less

  9. Electro-Optic Frequency Beam Splitters and Tritters for High-Fidelity Photonic Quantum Information Processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Hsuan-Hao; Lukens, Joseph M.; Peters, Nicholas A.

    In this paper, we report the experimental realization of high-fidelity photonic quantum gates for frequency-encoded qubits and qutrits based on electro-optic modulation and Fourier-transform pulse shaping. Our frequency version of the Hadamard gate offers near-unity fidelity (0.99998±0.00003), requires only a single microwave drive tone for near-ideal performance, functions across the entire C band (1530–1570 nm), and can operate concurrently on multiple qubits spaced as tightly as four frequency modes apart, with no observable degradation in the fidelity. For qutrits, we implement a 3×3 extension of the Hadamard gate: the balanced tritter. This tritter—the first ever demonstrated for frequency modes—attains fidelitymore » 0.9989±0.0004. Finally, these gates represent important building blocks toward scalable, high-fidelity quantum information processing based on frequency encoding.« less

  10. Rotorcraft Research at the NASA Vertical Motion Simulator

    NASA Technical Reports Server (NTRS)

    Aponso, Bimal Lalith; Tran, Duc T.; Schroeder, Jeffrey A.

    2009-01-01

    In the 1970 s the role of the military helicopter evolved to encompass more demanding missions including low-level nap-of-the-earth flight and operation in severely degraded visual environments. The Vertical Motion Simulator (VMS) at the NASA Ames Research Center was built to provide a high-fidelity simulation capability to research new rotorcraft concepts and technologies that could satisfy these mission requirements. The VMS combines a high-fidelity large amplitude motion system with an adaptable simulation environment including interchangeable and configurable cockpits. In almost 30 years of operation, rotorcraft research on the VMS has contributed significantly to the knowledge-base on rotorcraft performance, handling qualities, flight control, and guidance and displays. These contributions have directly benefited current rotorcraft programs and flight safety. The high fidelity motion system in the VMS was also used to research simulation fidelity. This research provided a fundamental understanding of pilot cueing modalities and their effect on simulation fidelity.

  11. Optimal control of hybrid qubits: Implementing the quantum permutation algorithm

    NASA Astrophysics Data System (ADS)

    Rivera-Ruiz, C. M.; de Lima, E. F.; Fanchini, F. F.; Lopez-Richard, V.; Castelano, L. K.

    2018-03-01

    The optimal quantum control theory is employed to determine electric pulses capable of producing quantum gates with a fidelity higher than 0.9997, when noise is not taken into account. Particularly, these quantum gates were chosen to perform the permutation algorithm in hybrid qubits in double quantum dots (DQDs). The permutation algorithm is an oracle based quantum algorithm that solves the problem of the permutation parity faster than a classical algorithm without the necessity of entanglement between particles. The only requirement for achieving the speedup is the use of a one-particle quantum system with at least three levels. The high fidelity found in our results is closely related to the quantum speed limit, which is a measure of how fast a quantum state can be manipulated. Furthermore, we model charge noise by considering an average over the optimal field centered at different values of the reference detuning, which follows a Gaussian distribution. When the Gaussian spread is of the order of 5 μ eV (10% of the correct value), the fidelity is still higher than 0.95. Our scheme also can be used for the practical realization of different quantum algorithms in DQDs.

  12. First-Order Frameworks for Managing Models in Engineering Optimization

    NASA Technical Reports Server (NTRS)

    Alexandrov, Natlia M.; Lewis, Robert Michael

    2000-01-01

    Approximation/model management optimization (AMMO) is a rigorous methodology for attaining solutions of high-fidelity optimization problems with minimal expense in high- fidelity function and derivative evaluation. First-order AMMO frameworks allow for a wide variety of models and underlying optimization algorithms. Recent demonstrations with aerodynamic optimization achieved three-fold savings in terms of high- fidelity function and derivative evaluation in the case of variable-resolution models and five-fold savings in the case of variable-fidelity physics models. The savings are problem dependent but certain trends are beginning to emerge. We give an overview of the first-order frameworks, current computational results, and an idea of the scope of the first-order framework applicability.

  13. The experiences of last-year student midwives with High-Fidelity Perinatal Simulation training: A qualitative descriptive study.

    PubMed

    Vermeulen, Joeri; Beeckman, Katrien; Turcksin, Rivka; Van Winkel, Lies; Gucciardo, Léonardo; Laubach, Monika; Peersman, Wim; Swinnen, Eva

    2017-06-01

    Simulation training is a powerful and evidence-based teaching method in healthcare. It allows students to develop essential competences that are often difficult to achieve during internships. High-Fidelity Perinatal Simulation exposes them to real-life scenarios in a safe environment. Although student midwives' experiences need to be considered to make the simulation training work, these have been overlooked so far. To explore the experiences of last-year student midwives with High-Fidelity Perinatal Simulation training. A qualitative descriptive study, using three focus group conversations with last-year student midwives (n=24). Audio tapes were transcribed and a thematic content analysis was performed. The entire data set was coded according to recurrent or common themes. To achieve investigator triangulation and confirm themes, discussions among the researchers was incorporated in the analysis. Students found High-Fidelity Perinatal Simulation training to be a positive learning method that increased both their competence and confidence. Their experiences varied over the different phases of the High-Fidelity Perinatal Simulation training. Although uncertainty, tension, confusion and disappointment were experienced throughout the simulation trajectory, they reported that this did not affect their learning and confidence-building. As High-Fidelity Perinatal Simulation training constitutes a helpful learning experience in midwifery education, it could have a positive influence on maternal and neonatal outcomes. In the long term, it could therefore enhance the midwifery profession in several ways. The present study is an important first step in opening up the debate about the pedagogical use of High-Fidelity Perinatal Simulation training within midwifery education. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  14. [Acquiring skills in malignant hyperthermia crisis management: comparison of high-fidelity simulation versus computer-based case study].

    PubMed

    Mejía, Vilma; Gonzalez, Carlos; Delfino, Alejandro E; Altermatt, Fernando R; Corvetto, Marcia A

    The primary purpose of this study was to compare the effect of high fidelity simulation versus a computer-based case solving self-study, in skills acquisition about malignant hyperthermia on first year anesthesiology residents. After institutional ethical committee approval, 31 first year anesthesiology residents were enrolled in this prospective randomized single-blinded study. Participants were randomized to either a High Fidelity Simulation Scenario or a computer-based Case Study about malignant hyperthermia. After the intervention, all subjects' performance in was assessed through a high fidelity simulation scenario using a previously validated assessment rubric. Additionally, knowledge tests and a satisfaction survey were applied. Finally, a semi-structured interview was done to assess self-perception of reasoning process and decision-making. 28 first year residents finished successfully the study. Resident's management skill scores were globally higher in High Fidelity Simulation versus Case Study, however they were significant in 4 of the 8 performance rubric elements: recognize signs and symptoms (p = 0.025), prioritization of initial actions of management (p = 0.003), recognize complications (p = 0.025) and communication (p = 0.025). Average scores from pre- and post-test knowledge questionnaires improved from 74% to 85% in the High Fidelity Simulation group, and decreased from 78% to 75% in the Case Study group (p = 0.032). Regarding the qualitative analysis, there was no difference in factors influencing the student's process of reasoning and decision-making with both teaching strategies. Simulation-based training with a malignant hyperthermia high-fidelity scenario was superior to computer-based case study, improving knowledge and skills in malignant hyperthermia crisis management, with a very good satisfaction level in anesthesia residents. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  15. Modeling the Space Debris Environment with MASTER-2009 and ORDEM2010

    NASA Technical Reports Server (NTRS)

    Flegel, S.; Gelhaus, J.; Wiedemann, C.; Mockel, M.; Vorsmann, P.; Krisko, P.; Xu, Y. -L.; Horstman, M. F.; Opiela, J. N.; Matney, M.; hide

    2010-01-01

    Spacecraft analysis using ORDEM2010 uses a high-fidelity population model to compute risk to on-orbit assets. The ORDEM2010 GUI allows visualization of spacecraft flux in 2-D and 1-D. The population was produced using a Bayesian statistical approach with measured and modeled environment data. Validation of sizes < 1mm were performed using Shuttle window and radiator impact measurements. Validation of sizes > 1mm is on-going.

  16. Forecasting Science and Technology for the Department of Defense

    DTIC Science & Technology

    2009-12-01

    Watson and Francis Crick announced that they had elucidated the structure of DNA and had therefore “discovered the secret of life.” While this was a...an organic chemist, figured out a process by which very small quantities of DNA could be amplified with high fidelity. This process, known as...polymerase chain reaction (PCR), for the first time, allowed scientists to produce DNA in large quantities. Roughly during this period, Leroy Hood and

  17. Applications of fidelity measures to complex quantum systems

    PubMed Central

    2016-01-01

    We revisit fidelity as a measure for the stability and the complexity of the quantum motion of single-and many-body systems. Within the context of cold atoms, we present an overview of applications of two fidelities, which we call static and dynamical fidelity, respectively. The static fidelity applies to quantum problems which can be diagonalized since it is defined via the eigenfunctions. In particular, we show that the static fidelity is a highly effective practical detector of avoided crossings characterizing the complexity of the systems and their evolutions. The dynamical fidelity is defined via the time-dependent wave functions. Focusing on the quantum kicked rotor system, we highlight a few practical applications of fidelity measurements in order to better understand the large variety of dynamical regimes of this paradigm of a low-dimensional system with mixed regular–chaotic phase space. PMID:27140967

  18. Implementation of a Text-Based Content Intervention in Secondary Social Studies Classes.

    PubMed

    Wanzek, Jeanne; Vaughn, Sharon

    2016-12-01

    We describe teacher fidelity (adherence to the components of the treatment as specified by the research team) based on a series of studies of a multicomponent intervention, Promoting Acceleration of Comprehension and Content Through Text (PACT), with middle and high school social studies teachers and their students. Findings reveal that even with highly specified materials and implementing practices that are aligned with effective reading comprehension and content instruction, teachers' fidelity was consistently low for some components and high for others. Teachers demonstrated consistently high implementation fidelity and quality for the instructional components of building background knowledge (comprehension canopy) and teaching key content vocabulary (essential words), whereas we recorded consistently lower fidelity and quality of implementation for the instructional components of critical reading and knowledge application. © 2016 Wiley Periodicals, Inc.

  19. High-fidelity gates in quantum dot spin qubits.

    PubMed

    Koh, Teck Seng; Coppersmith, S N; Friesen, Mark

    2013-12-03

    Several logical qubits and quantum gates have been proposed for semiconductor quantum dots controlled by voltages applied to top gates. The different schemes can be difficult to compare meaningfully. Here we develop a theoretical framework to evaluate disparate qubit-gating schemes on an equal footing. We apply the procedure to two types of double-dot qubits: the singlet-triplet and the semiconducting quantum dot hybrid qubit. We investigate three quantum gates that flip the qubit state: a DC pulsed gate, an AC gate based on logical qubit resonance, and a gate-like process known as stimulated Raman adiabatic passage. These gates are all mediated by an exchange interaction that is controlled experimentally using the interdot tunnel coupling g and the detuning [Symbol: see text], which sets the energy difference between the dots. Our procedure has two steps. First, we optimize the gate fidelity (f) for fixed g as a function of the other control parameters; this yields an f(opt)(g) that is universal for different types of gates. Next, we identify physical constraints on the control parameters; this yields an upper bound f(max) that is specific to the qubit-gate combination. We show that similar gate fidelities (~99:5%) should be attainable for singlet-triplet qubits in isotopically purified Si, and for hybrid qubits in natural Si. Considerably lower fidelities are obtained for GaAs devices, due to the fluctuating magnetic fields ΔB produced by nuclear spins.

  20. Effects of VR system fidelity on analyzing isosurface visualization of volume datasets.

    PubMed

    Laha, Bireswar; Bowman, Doug A; Socha, John J

    2014-04-01

    Volume visualization is an important technique for analyzing datasets from a variety of different scientific domains. Volume data analysis is inherently difficult because volumes are three-dimensional, dense, and unfamiliar, requiring scientists to precisely control the viewpoint and to make precise spatial judgments. Researchers have proposed that more immersive (higher fidelity) VR systems might improve task performance with volume datasets, and significant results tied to different components of display fidelity have been reported. However, more information is needed to generalize these results to different task types, domains, and rendering styles. We visualized isosurfaces extracted from synchrotron microscopic computed tomography (SR-μCT) scans of beetles, in a CAVE-like display. We ran a controlled experiment evaluating the effects of three components of system fidelity (field of regard, stereoscopy, and head tracking) on a variety of abstract task categories that are applicable to various scientific domains, and also compared our results with those from our prior experiment using 3D texture-based rendering. We report many significant findings. For example, for search and spatial judgment tasks with isosurface visualization, a stereoscopic display provides better performance, but for tasks with 3D texture-based rendering, displays with higher field of regard were more effective, independent of the levels of the other display components. We also found that systems with high field of regard and head tracking improve performance in spatial judgment tasks. Our results extend existing knowledge and produce new guidelines for designing VR systems to improve the effectiveness of volume data analysis.

  1. Enabling parallel simulation of large-scale HPC network systems

    DOE PAGES

    Mubarak, Misbah; Carothers, Christopher D.; Ross, Robert B.; ...

    2016-04-07

    Here, with the increasing complexity of today’s high-performance computing (HPC) architectures, simulation has become an indispensable tool for exploring the design space of HPC systems—in particular, networks. In order to make effective design decisions, simulations of these systems must possess the following properties: (1) have high accuracy and fidelity, (2) produce results in a timely manner, and (3) be able to analyze a broad range of network workloads. Most state-of-the-art HPC network simulation frameworks, however, are constrained in one or more of these areas. In this work, we present a simulation framework for modeling two important classes of networks usedmore » in today’s IBM and Cray supercomputers: torus and dragonfly networks. We use the Co-Design of Multi-layer Exascale Storage Architecture (CODES) simulation framework to simulate these network topologies at a flit-level detail using the Rensselaer Optimistic Simulation System (ROSS) for parallel discrete-event simulation. Our simulation framework meets all the requirements of a practical network simulation and can assist network designers in design space exploration. First, it uses validated and detailed flit-level network models to provide an accurate and high-fidelity network simulation. Second, instead of relying on serial time-stepped or traditional conservative discrete-event simulations that limit simulation scalability and efficiency, we use the optimistic event-scheduling capability of ROSS to achieve efficient and scalable HPC network simulations on today’s high-performance cluster systems. Third, our models give network designers a choice in simulating a broad range of network workloads, including HPC application workloads using detailed network traces, an ability that is rarely offered in parallel with high-fidelity network simulations« less

  2. Enabling parallel simulation of large-scale HPC network systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mubarak, Misbah; Carothers, Christopher D.; Ross, Robert B.

    Here, with the increasing complexity of today’s high-performance computing (HPC) architectures, simulation has become an indispensable tool for exploring the design space of HPC systems—in particular, networks. In order to make effective design decisions, simulations of these systems must possess the following properties: (1) have high accuracy and fidelity, (2) produce results in a timely manner, and (3) be able to analyze a broad range of network workloads. Most state-of-the-art HPC network simulation frameworks, however, are constrained in one or more of these areas. In this work, we present a simulation framework for modeling two important classes of networks usedmore » in today’s IBM and Cray supercomputers: torus and dragonfly networks. We use the Co-Design of Multi-layer Exascale Storage Architecture (CODES) simulation framework to simulate these network topologies at a flit-level detail using the Rensselaer Optimistic Simulation System (ROSS) for parallel discrete-event simulation. Our simulation framework meets all the requirements of a practical network simulation and can assist network designers in design space exploration. First, it uses validated and detailed flit-level network models to provide an accurate and high-fidelity network simulation. Second, instead of relying on serial time-stepped or traditional conservative discrete-event simulations that limit simulation scalability and efficiency, we use the optimistic event-scheduling capability of ROSS to achieve efficient and scalable HPC network simulations on today’s high-performance cluster systems. Third, our models give network designers a choice in simulating a broad range of network workloads, including HPC application workloads using detailed network traces, an ability that is rarely offered in parallel with high-fidelity network simulations« less

  3. A high-quality high-fidelity visualization of the September 11 attack on the World Trade Center.

    PubMed

    Rosen, Paul; Popescu, Voicu; Hoffmann, Christoph; Irfanoglu, Ayhan

    2008-01-01

    In this application paper, we describe the efforts of a multidisciplinary team towards producing a visualization of the September 11 Attack on the North Tower of New York's World Trade Center. The visualization was designed to meet two requirements. First, the visualization had to depict the impact with high fidelity, by closely following the laws of physics. Second, the visualization had to be eloquent to a nonexpert user. This was achieved by first designing and computing a finite-element analysis (FEA) simulation of the impact between the aircraft and the top 20 stories of the building, and then by visualizing the FEA results with a state-of-the-art commercial animation system. The visualization was enabled by an automatic translator that converts the simulation data into an animation system 3D scene. We built upon a previously developed translator. The translator was substantially extended to enable and control visualization of fire and of disintegrating elements, to better scale with the number of nodes and number of states, to handle beam elements with complex profiles, and to handle smoothed particle hydrodynamics liquid representation. The resulting translator is a powerful automatic and scalable tool for high-quality visualization of FEA results.

  4. Low fidelity, high quality: a model for e-learning.

    PubMed

    Gordon, Morris; Chandratilake, Madawa; Baker, Paul

    2013-08-01

    E-learning continues to proliferate as a method to deliver continuing medical education. The effectiveness of e-learning has been widely studied, showing that it is as effective as traditional forms of education. However, most reports focus on whether the e-learning is effective, rather than discussing innovations to allow clinical educators to ask 'how' and 'why' it is effective, and to facilitate local reproduction. Previous work has set out a number of barriers to the introduction of e-learning interventions. Cost, the time to produce interventions, and the training requirements for educators and trainees have all been identified as barriers. We set out to design an e-learning intervention on paediatric prescribing that could address these issues using a low-fidelity approach, and report our methods so as to allow interested readers to use a similar approach. Using low-cost, readily accessible tools and applying appropriate educational theory, the intervention was produced in a short period of time. As part of a randomised controlled trial, long-term retention of prescribing skills was demonstrated, with significantly higher prescribing skill scores in the e-learning group at 4 and 12 weeks (p < 0.0001). Feedback was universally positive, with Likert responses suggesting that it was useful, convenient and easy to use. A low-fidelity approach to designing can successfully overcome many of the barriers to the introduction of e-learning. The design model described is simple and can be used by clinical teachers to support local development. Further research could investigate the experiences of these clinicians using this method of instructional design. © 2013 John Wiley & Sons Ltd.

  5. Stimulated Brillouin scattering continuous wave phase conjugation in step-index fiber optics.

    PubMed

    Massey, Steven M; Spring, Justin B; Russell, Timothy H

    2008-07-21

    Continuous wave (CW) stimulated Brillouin scattering (SBS) phase conjugation in step-index optical fibers was studied experimentally and modeled as a function of fiber length. A phase conjugate fidelity over 80% was measured from SBS in a 40 m fiber using a pinhole technique. Fidelity decreases with fiber length, and a fiber with a numerical aperture (NA) of 0.06 was found to generate good phase conjugation fidelity over longer lengths than a fiber with 0.13 NA. Modeling and experiment support previous work showing the maximum interaction length which yields a high fidelity phase conjugate beam is inversely proportional to the fiber NA(2), but find that fidelity remains high over much longer fiber lengths than previous models calculated. Conditions for SBS beam cleanup in step-index fibers are discussed.

  6. Integrated simulations for fusion research in the 2030's time frame (white paper outline)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, Alex; LoDestro, Lynda L.; Parker, Jeffrey B.

    This white paper presents the rationale for developing a community-wide capability for whole-device modeling, and advocates for an effort with the expectation of persistence: a long-term programmatic commitment, and support for community efforts. Statement of 2030 goal (two suggestions): (a) Robust integrated simulation tools to aid real-time experimental discharges and reactor designs by employing a hierarchy in fidelity of physics models. (b) To produce by the early 2030s a capability for validated, predictive simulation via integration of a suite of physics models from moderate through high fidelity, to understand and plan full plasma discharges, aid in data interpretation, carry outmore » discovery science, and optimize future machine designs. We can achieve this goal via a focused effort to extend current scientific capabilities and rigorously integrate simulations of disparate physics into a comprehensive set of workflows.« less

  7. High Fidelity Virtual Environments: Does Shader Quality or Higher Polygon Count Models Increase Presence and Learning

    NASA Astrophysics Data System (ADS)

    Horton, Scott

    This research study investigated the effects of high fidelity graphics on both learning and presence, or the "sense of being there," inside a Virtual Learning Environment (VLE). Four versions of a VLE on the subject of the element mercury were created, each with a different combination of high and low fidelity polygon models and high and low fidelity shaders. A total of 76 college age (18+ years of age) participants were randomly assigned to one of the four conditions. The participants interacted with the VLE and then completed several posttest measures on learning, presence, and attitudes towards the VLE experience. Demographic information was also collected, including age, computer gameplay experience, number of virtual environments interacted with, gender and time spent in this virtual environment. The data was analyzed as a 2 x 2 between subjects ANOVA. The main effects of shader fidelity and polygon fidelity were both non-significant for both learning and all presence subscales inside the VLE. In addition, there was no significant interaction between shader fidelity and model fidelity. However, there were two significant results on the supplementary variables. First, gender was found to have a significant main effect on all the presence subscales. Females reported higher average levels of presence than their male counterparts. Second, gameplay hours, or the number of hours a participant played computer games per week, also had a significant main effect on participant score on the learning measure. The participants who reported playing 15+ hours of computer games per week, the highest amount of time in the variable, had the highest score as a group on the mercury learning measure while those participants that played 1-5 hours per week had the lowest scores.

  8. Teaching Elliptical Excision Skills to Novice Medical Students: A Randomized Controlled Study Comparing Low- and High-Fidelity Bench Models

    PubMed Central

    Denadai, Rafael; Oshiiwa, Marie; Saad-Hossne, Rogério

    2014-01-01

    Background: The search for alternative and effective forms of training simulation is needed due to ethical and medico-legal aspects involved in training surgical skills on living patients, human cadavers and living animals. Aims: To evaluate if the bench model fidelity interferes in the acquisition of elliptical excision skills by novice medical students. Materials and Methods: Forty novice medical students were randomly assigned to 5 practice conditions with instructor-directed elliptical excision skills’ training (n = 8): didactic materials (control); organic bench model (low-fidelity); ethylene-vinyl acetate bench model (low-fidelity); chicken legs’ skin bench model (high-fidelity); or pig foot skin bench model (high-fidelity). Pre- and post-tests were applied. Global rating scale, effect size, and self-perceived confidence based on Likert scale were used to evaluate all elliptical excision performances. Results: The analysis showed that after training, the students practicing on bench models had better performance based on Global rating scale (all P < 0.0000) and felt more confident to perform elliptical excision skills (all P < 0.0000) when compared to the control. There was no significant difference (all P > 0.05) between the groups that trained on bench models. The magnitude of the effect (basic cutaneous surgery skills’ training) was considered large (>0.80) in all measurements. Conclusion: The acquisition of elliptical excision skills after instructor-directed training on low-fidelity bench models was similar to the training on high-fidelity bench models; and there was a more substantial increase in elliptical excision performances of students that trained on all simulators compared to the learning on didactic materials. PMID:24700937

  9. Use of High Fidelity Methods in Multidisciplinary Optimization-A Preliminary Survey

    NASA Technical Reports Server (NTRS)

    Guruswamy, Guru P.; Kwak, Dochan (Technical Monitor)

    2002-01-01

    Multidisciplinary optimization is a key element of design process. To date multidiscipline optimization methods that use low fidelity methods are well advanced. Optimization methods based on simple linear aerodynamic equations and plate structural equations have been applied to complex aerospace configurations. However, use of high fidelity methods such as the Euler/ Navier-Stokes for fluids and 3-D (three dimensional) finite elements for structures has begun recently. As an activity of Multidiscipline Design Optimization Technical Committee (MDO TC) of AIAA (American Institute of Aeronautics and Astronautics), an effort was initiated to assess the status of the use of high fidelity methods in multidisciplinary optimization. Contributions were solicited through the members MDO TC committee. This paper provides a summary of that survey.

  10. Measuring trainer fidelity in the transfer of suicide prevention training

    PubMed Central

    Cross, Wendi F.; Pisani, Anthony R.; Schmeelk-Cone, Karen; Xia, Yinglin; Tu, Xin; McMahon, Marcie; Munfakh, Jimmie Lou; Gould, Madelyn S.

    2014-01-01

    Background Finding effective and efficient models to train large numbers of suicide prevention interventionists, including ‘hotline’ crisis counselors, is a high priority. Train-the-trainer (TTT) models are widely used but understudied. Aims To assess the extent to which trainers following TTT delivered the Applied Suicide Intervention Skills Training (ASIST) program with fidelity, and to examine fidelity across two trainings and seven training segments. Methods We recorded and reliably rated trainer fidelity, defined as adherence to program content and competence of program delivery, for 34 newly trained ASIST trainers delivering the program to crisis center staff on two separate occasions. A total of 324 observations were coded. Trainer demographics were also collected. Results On average, trainers delivered two-thirds of the program. Previous training was associated with lower levels of trainer adherence to the program. 18% of trainers' observations were rated as solidly competent. Trainers did not improve fidelity from their first to second training. Significantly higher fidelity was found for lectures and lower fidelity was found for interactive training activities including asking about suicide and creating a safe plan. Conclusions We found wide variability in trainer fidelity to the ASIST program following TTT and few trainers had high levels of both adherence and competence. More research is needed to examine the cost-effectiveness of TTT models. PMID:24901061

  11. Preschool children's development in classic Montessori, supplemented Montessori, and conventional programs.

    PubMed

    Lillard, Angeline S

    2012-06-01

    Research on the outcomes of Montessori education is scarce and results are inconsistent. One possible reason for the inconsistency is variations in Montessori implementation fidelity. To test whether outcomes vary according to implementation fidelity, we examined preschool children enrolled in high fidelity classic Montessori programs, lower fidelity Montessori programs that supplemented the program with conventional school activities, and, for comparison, conventional programs. Children were tested at the start and end of the school year on a range of social and academic skills. Although they performed no better in the fall, children in Classic Montessori programs, as compared with children in Supplemented Montessori and Conventional programs, showed significantly greater school-year gains on outcome measures of executive function, reading, math, vocabulary, and social problem-solving, suggesting that high fidelity Montessori implementation is associated with better outcomes than lower fidelity Montessori programs or conventional programs. Copyright © 2012 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  12. An Investigation of the Impact of Aerodynamic Model Fidelity on Close-In Combat Effectiveness Prediction in Piloted Simulation

    NASA Technical Reports Server (NTRS)

    Persing, T. Ray; Bellish, Christine A.; Brandon, Jay; Kenney, P. Sean; Carzoo, Susan; Buttrill, Catherine; Guenther, Arlene

    2005-01-01

    Several aircraft airframe modeling approaches are currently being used in the DoD community for acquisition, threat evaluation, training, and other purposes. To date there has been no clear empirical study of the impact of airframe simulation fidelity on piloted real-time aircraft simulation study results, or when use of a particular level of fidelity is indicated. This paper documents a series of piloted simulation studies using three different levels of airframe model fidelity. This study was conducted using the NASA Langley Differential Maneuvering Simulator. Evaluations were conducted with three pilots for scenarios requiring extensive maneuvering of the airplanes during air combat. In many cases, a low-fidelity modified point-mass model may be sufficient to evaluate the combat effectiveness of the aircraft. However, in cases where high angle-of-attack flying qualities and aerodynamic performance are a factor or when precision tracking ability of the aircraft must be represented, use of high-fidelity models is indicated.

  13. Comparison of Performance Predictions for New Low-Thrust Trajectory Tools

    NASA Technical Reports Server (NTRS)

    Polsgrove, Tara; Kos, Larry; Hopkins, Randall; Crane, Tracie

    2006-01-01

    Several low thrust trajectory optimization tools have been developed over the last 3% years by the Low Thrust Trajectory Tools development team. This toolset includes both low-medium fidelity and high fidelity tools which allow the analyst to quickly research a wide mission trade space and perform advanced mission design. These tools were tested using a set of reference trajectories that exercised each tool s unique capabilities. This paper compares the performance predictions of the various tools against several of the reference trajectories. The intent is to verify agreement between the high fidelity tools and to quantify the performance prediction differences between tools of different fidelity levels.

  14. A Transfer of Training Study of Control Loader Dynamics

    NASA Technical Reports Server (NTRS)

    Cardullo, Frank M.; Stanco, Anthony A.; Kelly, Lon C.; Houck, Jacob A.; Grube, Richard C.

    2011-01-01

    The control inceptor used in a simulated vehicle is an important part in maintaining the fidelity of a simulation. The force feedback provided by the control inceptor gives the operator important cues to maintain adequate performance. The dynamics of a control inceptor are typically based on a second order spring mass damper system with damping, force gradient, breakout force, and natural frequency parameters. Changing these parameters can have a great effect on pilot or driver control of the vehicle. The neuromuscular system has a very important role in manipulating the control inceptor within a vehicle. Many studies by McRuer, Aponso, and Hess have dealt with modeling the neuromuscular system and quantifying the effects of a high fidelity control loader as compared to a low fidelity control loader. Humans are adaptive in nature and their control behavior changes based on different control loader dynamics. Humans will change their control behavior to maintain tracking bandwidth and minimize tracking error. This paper reports on a quasi-transfer of training experiment which was performed at the NASA Langley Research Center. The quasi transfer of training study used a high fidelity control loader and a low fidelity control loader. Subjects trained in both simulations and then were transferred to the high fidelity control loader simulation. The parameters for the high fidelity control loader were determined from the literature. The low fidelity control loader parameters were found through testing of a simple computer joystick. A disturbance compensatory task is employed. The compensatory task involves implementing a simple horizon out the window display. A disturbance consisting of a sum of sines is used. The task consists of the subject compensating for the disturbance on the roll angle of the aircraft. The vehicle dynamics are represented as 1/s and 1/s2. The subject will try to maintain level flight throughout the experiment. The subjects consist of non-pilots to remove any effects of pilot experience. First, this paper discusses the implementation of the disturbance compensation task. Second, the high and low fidelity parameters used within the experiment are presented. Finally, an explanation of results from the experiments is presented.

  15. The effect of simulator fidelity on acquiring non-technical skills: a randomized non-inferiority trial.

    PubMed

    Gu, Yuqi; Witter, Tobias; Livingston, Patty; Rao, Purnima; Varshney, Terry; Kuca, Tom; Dylan Bould, M

    2017-12-01

    As simulator fidelity (i.e., realism) increases from low to high, the simulator more closely resembles the real environment, but it also becomes more expensive. It is generally assumed that the use of high-fidelity simulators results in better learning; however, the effect of fidelity on learning non-technical skills (NTS) is unknown. This was a non-inferiority trial comparing the efficacy of high- vs low-fidelity simulators on learning NTS. Thirty-six postgraduate medical trainees were recruited for the trial. During the pre-test phase, the trainees were randomly assigned to manage a scenario using either a high-fidelity simulator (HFS) or a low-fidelity simulator (LFS), followed by expert debriefing. All trainees then underwent a video recorded post-test scenario on a HFS, and the NTS were assessed between the two groups. The primary outcome was the overall post-test Ottawa Global Rating Scale (OGRS), while controlling for overall pre-test OGRS scores. Non-inferiority between the LFS and HFS was based on a non-inferiority margin of greater than 1. For our primary outcome, the mean (SD) post-test overall OGRS score was not significantly different between the HFS and LFS groups after controlling for pre-test overall OGRS scores [3.8 (0.9) vs 4.0 (0.9), respectively; mean difference, 0.2; 95% confidence interval, -0.4 to 0.8; P = 0.48]. For our secondary outcomes, the post-test total OGRS score was not significantly different between the HFS and LFS groups after controlling for pre-test total OGRS scores (P = 0.33). There were significant improvements in mean overall (P = 0.01) and total (P = 0.003) OGRS scores from pre-test to post-test. There were no significant associations between postgraduate year (P = 0.82) and specialty (P = 0.67) on overall OGRS performance. This study suggests that low-fidelity simulators are non-inferior to the more costly high-fidelity simulators for teaching NTS to postgraduate medical trainees.

  16. Using mixed methods to assess fidelity of delivery and its influencing factors in a complex self-management intervention for people with osteoarthritis and low back pain.

    PubMed

    Toomey, Elaine; Matthews, James; Hurley, Deirdre A

    2017-08-04

    Despite an increasing awareness of the importance of fidelity of delivery within complex behaviour change interventions, it is often poorly assessed. This mixed methods study aimed to establish the fidelity of delivery of a complex self-management intervention and explore the reasons for these findings using a convergent/triangulation design. Feasibility trial of the Self-management of Osteoarthritis and Low back pain through Activity and Skills (SOLAS) intervention (ISRCTN49875385), delivered in primary care physiotherapy. 60 SOLAS sessions were delivered across seven sites by nine physiotherapists. Fidelity of delivery of prespecified intervention components was evaluated using (1) audio-recordings (n=60), direct observations (n=24) and self-report checklists (n=60) and (2) individual interviews with physiotherapists (n=9). Quantitatively, fidelity scores were calculated using percentage means and SD of components delivered. Associations between fidelity scores and physiotherapist variables were analysed using Spearman's correlations. Interviews were analysed using thematic analysis to explore potential reasons for fidelity scores. Integration of quantitative and qualitative data occurred at an interpretation level using triangulation. Quantitatively, fidelity scores were high for all assessment methods; with self-report (92.7%) consistently higher than direct observations (82.7%) or audio-recordings (81.7%). There was significant variation between physiotherapists' individual scores (69.8% - 100%). Both qualitative and quantitative data (from physiotherapist variables) found that physiotherapists' knowledge (Spearman's association at p=0.003) and previous experience (p=0.008) were factors that influenced their fidelity. The qualitative data also postulated participant-level (eg, individual needs) and programme-level factors (eg, resources) as additional elements that influenced fidelity. The intervention was delivered with high fidelity. This study contributes to the limited evidence regarding fidelity assessment methods within complex behaviour change interventions. The findings suggest a combination of quantitative methods is suitable for the assessment of fidelity of delivery. A mixed methods approach provided a more insightful understanding of fidelity and its influencing factors. ISRCTN49875385; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Using mixed methods to assess fidelity of delivery and its influencing factors in a complex self-management intervention for people with osteoarthritis and low back pain

    PubMed Central

    Toomey, Elaine; Matthews, James; Hurley, Deirdre A

    2017-01-01

    Objectives and design Despite an increasing awareness of the importance of fidelity of delivery within complex behaviour change interventions, it is often poorly assessed. This mixed methods study aimed to establish the fidelity of delivery of a complex self-management intervention and explore the reasons for these findings using a convergent/triangulation design. Setting Feasibility trial of the Self-management of Osteoarthritis and Low back pain through Activity and Skills (SOLAS) intervention (ISRCTN49875385), delivered in primary care physiotherapy. Methods and outcomes 60 SOLAS sessions were delivered across seven sites by nine physiotherapists. Fidelity of delivery of prespecified intervention components was evaluated using (1) audio-recordings (n=60), direct observations (n=24) and self-report checklists (n=60) and (2) individual interviews with physiotherapists (n=9). Quantitatively, fidelity scores were calculated using percentage means and SD of components delivered. Associations between fidelity scores and physiotherapist variables were analysed using Spearman’s correlations. Interviews were analysed using thematic analysis to explore potential reasons for fidelity scores. Integration of quantitative and qualitative data occurred at an interpretation level using triangulation. Results Quantitatively, fidelity scores were high for all assessment methods; with self-report (92.7%) consistently higher than direct observations (82.7%) or audio-recordings (81.7%). There was significant variation between physiotherapists’ individual scores (69.8% - 100%). Both qualitative and quantitative data (from physiotherapist variables) found that physiotherapists’ knowledge (Spearman’s association at p=0.003) and previous experience (p=0.008) were factors that influenced their fidelity. The qualitative data also postulated participant-level (eg, individual needs) and programme-level factors (eg, resources) as additional elements that influenced fidelity. Conclusion The intervention was delivered with high fidelity. This study contributes to the limited evidence regarding fidelity assessment methods within complex behaviour change interventions. The findings suggest a combination of quantitative methods is suitable for the assessment of fidelity of delivery. A mixed methods approach provided a more insightful understanding of fidelity and its influencing factors. Trial registration number ISRCTN49875385; Pre-results. PMID:28780544

  18. Graphics Processing Units (GPU) and the Goddard Earth Observing System atmospheric model (GEOS-5): Implementation and Potential Applications

    NASA Technical Reports Server (NTRS)

    Putnam, William M.

    2011-01-01

    Earth system models like the Goddard Earth Observing System model (GEOS-5) have been pushing the limits of large clusters of multi-core microprocessors, producing breath-taking fidelity in resolving cloud systems at a global scale. GPU computing presents an opportunity for improving the efficiency of these leading edge models. A GPU implementation of GEOS-5 will facilitate the use of cloud-system resolving resolutions in data assimilation and weather prediction, at resolutions near 3.5 km, improving our ability to extract detailed information from high-resolution satellite observations and ultimately produce better weather and climate predictions

  19. High-fidelity gates towards a scalable superconducting quantum processor

    NASA Astrophysics Data System (ADS)

    Chow, Jerry M.; Corcoles, Antonio D.; Gambetta, Jay M.; Rigetti, Chad; Johnson, Blake R.; Smolin, John A.; Merkel, Seth; Poletto, Stefano; Rozen, Jim; Rothwell, Mary Beth; Keefe, George A.; Ketchen, Mark B.; Steffen, Matthias

    2012-02-01

    We experimentally explore the implementation of high-fidelity gates on multiple superconducting qubits coupled to multiple resonators. Having demonstrated all-microwave single and two qubit gates with fidelities > 90% on multi-qubit single-resonator systems, we expand the application to qubits across two resonators and investigate qubit coupling in this circuit. The coupled qubit-resonators are building blocks towards two-dimensional lattice networks for the application of surface code quantum error correction algorithms.

  20. The efficacy of high-fidelity simulation on psychomotor clinical performance improvement of undergraduate nursing students.

    PubMed

    Vincent, Mary Anne; Sheriff, Susan; Mellott, Susan

    2015-02-01

    High-fidelity simulation has become a growing educational modality among institutions of higher learning ever since the Institute of Medicine recommended that it be used to improve patient safety in 2000. However, there is limited research on the effect of high-fidelity simulation on psychomotor clinical performance improvement of undergraduate nursing students being evaluated by experts using reliable and valid appraisal instruments. The purpose of this integrative review and meta-analysis is to explore what researchers have established about the impact of high-fidelity simulation on improving the psychomotor clinical performance of undergraduate nursing students. Only eight of the 1120 references met inclusion criteria. A meta-analysis using Hedges' g to compute the effect size and direction of impact yielded a range of -0.26 to +3.39. A positive effect was shown in seven of eight studies; however, there were five different research designs and six unique appraisal instruments used among these studies. More research is necessary to determine if high-fidelity simulation improves psychomotor clinical performance in undergraduate nursing students. Nursing programs from multiple sites having a standardized curriculum and using the same appraisal instruments with established reliability and validity are ideal for this work.

  1. Assessing fidelity of delivery of smoking cessation behavioural support in practice.

    PubMed

    Lorencatto, Fabiana; West, Robert; Christopherson, Charlotte; Michie, Susan

    2013-04-04

    Effectiveness of evidence-based behaviour change interventions is likely to be undermined by failure to deliver interventions as planned. Behavioural support for smoking cessation can be a highly cost-effective, life-saving intervention. However, in practice, outcomes are highly variable. Part of this may be due to variability in fidelity of intervention implementation. To date, there have been no published studies on this. The present study aimed to: evaluate a method for assessing fidelity of behavioural support; assess fidelity of delivery in two English Stop-Smoking Services; and compare the extent of fidelity according to session types, duration, individual practitioners, and component behaviour change techniques (BCTs). Treatment manuals and transcripts of 34 audio-recorded behavioural support sessions were obtained from two Stop-Smoking Services and coded into component BCTs using a taxonomy of 43 BCTs. Inter-rater reliability was assessed using percentage agreement. Fidelity was assessed by examining the proportion of BCTs specified in the manuals that were delivered in individual sessions. This was assessed by session type (i.e., pre-quit, quit, post-quit), duration, individual practitioner, and BCT. Inter-coder reliability was high (87.1%). On average, 66% of manual-specified BCTs were delivered per session (SD 15.3, range: 35% to 90%). In Service 1, average fidelity was highest for post-quit sessions (69%) and lowest for pre-quit (58%). In Service 2, fidelity was highest for quit-day (81%) and lowest for post-quit sessions (56%). Session duration was not significantly correlated with fidelity. Individual practitioner fidelity ranged from 55% to 78%. Individual manual-specified BCTs were delivered on average 63% of the time (SD 28.5, range: 0 to 100%). The extent to which smoking cessation behavioural support is delivered as specified in treatment manuals can be reliably assessed using transcripts of audiotaped sessions. This allows the investigation of the implementation of evidence-based practice in relation to smoking cessation, a first step in designing interventions to improve it. There are grounds for believing that fidelity in the English Stop-Smoking Services may be low and that routine monitoring is warranted.

  2. Leveraging routine clinical materials and mobile technology to assess CBT fidelity: the Innovative Methods to Assess Psychotherapy Practices (imAPP) study.

    PubMed

    Wiltsey Stirman, Shannon; Marques, Luana; Creed, Torrey A; Gutner, Cassidy A; DeRubeis, Robert; Barnett, Paul G; Kuhn, Eric; Suvak, Michael; Owen, Jason; Vogt, Dawne; Jo, Booil; Schoenwald, Sonja; Johnson, Clara; Mallard, Kera; Beristianos, Matthew; La Bash, Heidi

    2018-05-22

    Identifying scalable strategies for assessing fidelity is a key challenge in implementation science. However, for psychosocial interventions, the existing, reliable ways to test treatment fidelity quality are often labor intensive, and less burdensome strategies may not reflect actual clinical practice. Cognitive behavioral therapies (CBTs) provide clinicians with a set of effective core elements to help treat a multitude of disorders, which, evidence suggests, need to be delivered with fidelity to maximize potential client impact. The current "gold standard" for rating CBTs is rating recordings of therapy sessions, which is extremely time-consuming and requires a substantial amount of initial training. Although CBTs can vary based on the target disorder, one common element employed in most CBTs is the use of worksheets to identify specific behaviors and thoughts that affect a client's ability to recover. The present study will develop and evaluate an innovative new approach to rate CBT fidelity, by developing a universal CBT scoring system based on worksheets completed in therapy sessions. To develop a scoring system for CBT worksheets, we will compile common CBT elements from a variety of CBT worksheets for a range of psychiatric disorders and create adherence and competence measures. We will collect archival worksheets from past studies to test the scoring system and assess test-retest reliability. To evaluate whether CBT worksheet scoring accurately reflects clinician fidelity, we will recruit clinicians who are engaged in a CBT for depression, anxiety, and/or posttraumatic stress disorder. Clinicians and clients will transmit routine therapy materials produced in session (e.g., worksheets, clinical notes, session recordings) to the study team after each session. We will compare observer-rated fidelity, clinical notes, and fidelity-rated worksheets to identify the most effective and efficient method to assess clinician fidelity. Clients will also be randomly assigned to either complete the CBT worksheets on paper forms or on a mobile application (app) to learn if worksheet format influences clinician and client experience or differs in terms of reflecting fidelity. Scoring fidelity using CBT worksheets may allow clinics to test fidelity in a short and effective manner, enhancing continuous quality improvement in the workplace. Clinicians and clinics can use such data to improve clinician fidelity in real time, leading to improved patient outcomes. ClinicalTrials.gov NCT03479398 . Retrospectively registered March 20, 2018.

  3. Fidelity and outcomes in six integrated dual disorders treatment programs.

    PubMed

    Chandler, Daniel W

    2011-02-01

    Fidelity scores and outcomes were measured in six outpatient programs in California which implemented Integrated Dual Disorders Treatment (IDDT). Outcomes were measured for 1 year in four sites and 2 years in two sites; fidelity was assessed at 6 month intervals. Three of the six sites achieved high fidelity (at least a 4 on a 5 point fidelity scale) and three moderate fidelity (at least a 3). Retention in treatment, mental health functioning, stage of substance abuse treatment, abstinence, and psychiatric hospitalization were measured. Outcomes for individual programs were generally positive but not consistent within programs or across programs. Using pooled data in a longitudinal regression model with random effects at person level and adjustment of standard errors for clustering by site, change over time was not statistically significant for the primary outcomes. Fidelity scores had limited association with positive outcomes.

  4. Commentary: Learning from Variations in Fidelity of Implementation

    ERIC Educational Resources Information Center

    Balu, Rekha; Doolittle, Fred

    2016-01-01

    The articles in this special issue discuss efforts to improve academic reading outcomes for students and ways to achieve high implementation fidelity of promising strategies. At times the authors discuss if--and how--strong fidelity is associated with strong outcomes and potentially even impacts (the difference between program and control group…

  5. Preschool Children's Development in Classic Montessori, Supplemented Montessori, and Conventional Programs

    ERIC Educational Resources Information Center

    Lillard, Angeline S.

    2012-01-01

    Research on the outcomes of Montessori education is scarce and results are inconsistent. One possible reason for the inconsistency is variations in Montessori implementation fidelity. To test whether outcomes vary according to implementation fidelity, we examined preschool children enrolled in high fidelity classic Montessori programs, lower…

  6. Uncertainty quantification for PZT bimorph actuators

    NASA Astrophysics Data System (ADS)

    Bravo, Nikolas; Smith, Ralph C.; Crews, John

    2018-03-01

    In this paper, we discuss the development of a high fidelity model for a PZT bimorph actuator used for micro-air vehicles, which includes the Robobee. We developed a high-fidelity model for the actuator using the homogenized energy model (HEM) framework, which quantifies the nonlinear, hysteretic, and rate-dependent behavior inherent to PZT in dynamic operating regimes. We then discussed an inverse problem on the model. We included local and global sensitivity analysis of the parameters in the high-fidelity model. Finally, we will discuss the results of Bayesian inference and uncertainty quantification on the HEM.

  7. Machine vs. human translation of SNOMED CT terms.

    PubMed

    Schulz, Stefan; Bernhardt-Melischnig, Johannes; Kreuzthaler, Markus; Daumke, Philipp; Boeker, Martin

    2013-01-01

    In the context of past and current SNOMED CT translation projects we compare three kinds of SNOMED CT translations from English to German by: (t1) professional medical translators; (t2) a free Web-based machine translation service; (t3) medical students. 500 SNOMED CT fully specified names from the (English) International release were randomly selected. Based on this, German translations t1, t2, and t3 were generated. A German and an Austrian physician rated the translations for linguistic correctness and content fidelity. Kappa for inter-rater reliability was 0.4 for linguistic correctness and 0.23 for content fidelity. Average ratings of linguistic correctness did not differ significantly between human translation scenarios. Content fidelity was rated slightly better for student translators compared to professional translators. Comparing machine to human translation, the linguistic correctness differed about 0.5 scale units in favour of the human translation and about 0.25 regarding content fidelity, equally in favour of the human translation. The results demonstrate that low-cost translation solutions of medical terms may produce surprisingly good results. Although we would not recommend low-cost translation for producing standardized preferred terms, this approach can be useful for creating additional language-specific entry terms. This may serve several important use cases. We also recommend testing this method to bootstrap a crowdsourcing process, by which term translations are gathered, improved, maintained, and rated by the user community.

  8. Benefits of computer screen-based simulation in learning cardiac arrest procedures.

    PubMed

    Bonnetain, Elodie; Boucheix, Jean-Michel; Hamet, Maël; Freysz, Marc

    2010-07-01

    What is the best way to train medical students early so that they acquire basic skills in cardiopulmonary resuscitation as effectively as possible? Studies have shown the benefits of high-fidelity patient simulators, but have also demonstrated their limits. New computer screen-based multimedia simulators have fewer constraints than high-fidelity patient simulators. In this area, as yet, there has been no research on the effectiveness of transfer of learning from a computer screen-based simulator to more realistic situations such as those encountered with high-fidelity patient simulators. We tested the benefits of learning cardiac arrest procedures using a multimedia computer screen-based simulator in 28 Year 2 medical students. Just before the end of the traditional resuscitation course, we compared two groups. An experiment group (EG) was first asked to learn to perform the appropriate procedures in a cardiac arrest scenario (CA1) in the computer screen-based learning environment and was then tested on a high-fidelity patient simulator in another cardiac arrest simulation (CA2). While the EG was learning to perform CA1 procedures in the computer screen-based learning environment, a control group (CG) actively continued to learn cardiac arrest procedures using practical exercises in a traditional class environment. Both groups were given the same amount of practice, exercises and trials. The CG was then also tested on the high-fidelity patient simulator for CA2, after which it was asked to perform CA1 using the computer screen-based simulator. Performances with both simulators were scored on a precise 23-point scale. On the test on a high-fidelity patient simulator, the EG trained with a multimedia computer screen-based simulator performed significantly better than the CG trained with traditional exercises and practice (16.21 versus 11.13 of 23 possible points, respectively; p<0.001). Computer screen-based simulation appears to be effective in preparing learners to use high-fidelity patient simulators, which present simulations that are closer to real-life situations.

  9. The German VR Simulation Realism Scale--psychometric construction for virtual reality applications with virtual humans.

    PubMed

    Poeschl, Sandra; Doering, Nicola

    2013-01-01

    Virtual training applications with high levels of immersion or fidelity (for example for social phobia treatment) produce high levels of presence and therefore belong to the most successful Virtual Reality developments. Whereas display and interaction fidelity (as sub-dimensions of immersion) and their influence on presence are well researched, realism of the displayed simulation depends on the specific application and is therefore difficult to measure. We propose to measure simulation realism by using a self-report questionnaire. The German VR Simulation Realism Scale for VR training applications was developed based on a translation of scene realism items from the Witmer-Singer-Presence Questionnaire. Items for realism of virtual humans (for example for social phobia training applications) were supplemented. A sample of N = 151 students rated simulation realism of a Fear of Public Speaking application. Four factors were derived by item- and principle component analysis (Varimax rotation), representing Scene Realism, Audience Behavior, Audience Appearance and Sound Realism. The scale developed can be used as a starting point for future research and measurement of simulation realism for applications including virtual humans.

  10. Cooperative GN&C development in a rapid prototyping environment. [flight software design for space vehicles

    NASA Technical Reports Server (NTRS)

    Bordano, Aldo; Uhde-Lacovara, JO; Devall, Ray; Partin, Charles; Sugano, Jeff; Doane, Kent; Compton, Jim

    1993-01-01

    The Navigation, Control and Aeronautics Division (NCAD) at NASA-JSC is exploring ways of producing Guidance, Navigation and Control (GN&C) flight software faster, better, and cheaper. To achieve these goals NCAD established two hardware/software facilities that take an avionics design project from initial inception through high fidelity real-time hardware-in-the-loop testing. Commercially available software products are used to develop the GN&C algorithms in block diagram form and then automatically generate source code from these diagrams. A high fidelity real-time hardware-in-the-loop laboratory provides users with the capability to analyze mass memory usage within the targeted flight computer, verify hardware interfaces, conduct system level verification, performance, acceptance testing, as well as mission verification using reconfigurable and mission unique data. To evaluate these concepts and tools, NCAD embarked on a project to build a real-time 6 DOF simulation of the Soyuz Assured Crew Return Vehicle flight software. To date, a productivity increase of 185 percent has been seen over traditional NASA methods for developing flight software.

  11. High-fidelity data embedding for image annotation.

    PubMed

    He, Shan; Kirovski, Darko; Wu, Min

    2009-02-01

    High fidelity is a demanding requirement for data hiding, especially for images with artistic or medical value. This correspondence proposes a high-fidelity image watermarking for annotation with robustness to moderate distortion. To achieve the high fidelity of the embedded image, we introduce a visual perception model that aims at quantifying the local tolerance to noise for arbitrary imagery. Based on this model, we embed two kinds of watermarks: a pilot watermark that indicates the existence of the watermark and an information watermark that conveys a payload of several dozen bits. The objective is to embed 32 bits of metadata into a single image in such a way that it is robust to JPEG compression and cropping. We demonstrate the effectiveness of the visual model and the application of the proposed annotation technology using a database of challenging photographic and medical images that contain a large amount of smooth regions.

  12. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    NASA Astrophysics Data System (ADS)

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-11-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated.

  13. Surrogate based wind farm layout optimization using manifold mapping

    NASA Astrophysics Data System (ADS)

    Kaja Kamaludeen, Shaafi M.; van Zuijle, Alexander; Bijl, Hester

    2016-09-01

    High computational cost associated with the high fidelity wake models such as RANS or LES serves as a primary bottleneck to perform a direct high fidelity wind farm layout optimization (WFLO) using accurate CFD based wake models. Therefore, a surrogate based multi-fidelity WFLO methodology (SWFLO) is proposed. The surrogate model is built using an SBO method referred as manifold mapping (MM). As a verification, optimization of spacing between two staggered wind turbines was performed using the proposed surrogate based methodology and the performance was compared with that of direct optimization using high fidelity model. Significant reduction in computational cost was achieved using MM: a maximum computational cost reduction of 65%, while arriving at the same optima as that of direct high fidelity optimization. The similarity between the response of models, the number of mapping points and its position, highly influences the computational efficiency of the proposed method. As a proof of concept, realistic WFLO of a small 7-turbine wind farm is performed using the proposed surrogate based methodology. Two variants of Jensen wake model with different decay coefficients were used as the fine and coarse model. The proposed SWFLO method arrived at the same optima as that of the fine model with very less number of fine model simulations.

  14. High-fidelity teleportation beyond the no-cloning limit and entanglement swapping for continuous variables.

    PubMed

    Takei, Nobuyuki; Yonezawa, Hidehiro; Aoki, Takao; Furusawa, Akira

    2005-06-10

    We experimentally demonstrate continuous-variable quantum teleportation beyond the no-cloning limit. We teleport a coherent state and achieve the fidelity of 0.70 +/- 0.02 that surpasses the no-cloning limit of 2/3. Surpassing the limit is necessary to transfer the nonclassicality of an input quantum state. By using our high-fidelity teleporter, we demonstrate entanglement swapping, namely, teleportation of quantum entanglement, as an example of transfer of nonclassicality.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McInerney, Peter; Adams, Paul; Hadi, Masood Z.

    As larger-scale cloning projects become more prevalent, there is an increasing need for comparisons among high fidelity DNA polymerases used for PCR amplification. All polymerases marketed for PCR applications are tested for fidelity properties (i.e., error rate determination) by vendors, and numerous literature reports have addressed PCR enzyme fidelity. Nonetheless, it is often difficult to make direct comparisons among different enzymes due to numerous methodological and analytical differences from study to study. We have measured the error rates for 6 DNA polymerases commonly used in PCR applications, including 3 polymerases typically used for cloning applications requiring high fidelity. Error ratemore » measurement values reported here were obtained by direct sequencing of cloned PCR products. The strategy employed here allows interrogation of error rate across a very large DNA sequence space, since 94 unique DNA targets were used as templates for PCR cloning. The six enzymes included in the study, Taq polymerase, AccuPrime-Taq High Fidelity, KOD Hot Start, cloned Pfu polymerase, Phusion Hot Start, and Pwo polymerase, we find the lowest error rates with Pfu , Phusion, and Pwo polymerases. Error rates are comparable for these 3 enzymes and are >10x lower than the error rate observed with Taq polymerase. Mutation spectra are reported, with the 3 high fidelity enzymes displaying broadly similar types of mutations. For these enzymes, transition mutations predominate, with little bias observed for type of transition.« less

  16. Error Rate Comparison during Polymerase Chain Reaction by DNA Polymerase

    DOE PAGES

    McInerney, Peter; Adams, Paul; Hadi, Masood Z.

    2014-01-01

    As larger-scale cloning projects become more prevalent, there is an increasing need for comparisons among high fidelity DNA polymerases used for PCR amplification. All polymerases marketed for PCR applications are tested for fidelity properties (i.e., error rate determination) by vendors, and numerous literature reports have addressed PCR enzyme fidelity. Nonetheless, it is often difficult to make direct comparisons among different enzymes due to numerous methodological and analytical differences from study to study. We have measured the error rates for 6 DNA polymerases commonly used in PCR applications, including 3 polymerases typically used for cloning applications requiring high fidelity. Error ratemore » measurement values reported here were obtained by direct sequencing of cloned PCR products. The strategy employed here allows interrogation of error rate across a very large DNA sequence space, since 94 unique DNA targets were used as templates for PCR cloning. The six enzymes included in the study, Taq polymerase, AccuPrime-Taq High Fidelity, KOD Hot Start, cloned Pfu polymerase, Phusion Hot Start, and Pwo polymerase, we find the lowest error rates with Pfu , Phusion, and Pwo polymerases. Error rates are comparable for these 3 enzymes and are >10x lower than the error rate observed with Taq polymerase. Mutation spectra are reported, with the 3 high fidelity enzymes displaying broadly similar types of mutations. For these enzymes, transition mutations predominate, with little bias observed for type of transition.« less

  17. Trapped Ion Qubits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maunz, Peter; Wilhelm, Lukas

    Qubits can be encoded in clock states of trapped ions. These states are well isolated from the environment resulting in long coherence times [1] while enabling efficient high-fidelity qubit interactions mediated by the Coulomb coupled motion of the ions in the trap. Quantum states can be prepared with high fidelity and measured efficiently using fluorescence detection. State preparation and detection with 99.93% fidelity have been realized in multiple systems [1,2]. Single qubit gates have been demonstrated below rigorous fault-tolerance thresholds [1,3]. Two qubit gates have been realized with more than 99.9% fidelity [4,5]. Quantum algorithms have been demonstrated on systemsmore » of 5 to 15 qubits [6–8].« less

  18. Driving many distant atoms into high-fidelity steady state entanglement via Lyapunov control.

    PubMed

    Li, Chuang; Song, Jie; Xia, Yan; Ding, Weiqiang

    2018-01-22

    Based on Lyapunov control theory in closed and open systems, we propose a scheme to generate W state of many distant atoms in the cavity-fiber-cavity system. In the closed system, the W state is generated successfully even when the coupling strength between the cavity and fiber is extremely weak. In the presence of atomic spontaneous emission or cavity and fiber decay, the photon-measurement and quantum feedback approaches are proposed to improve the fidelity, which enable efficient generation of high-fidelity W state in the case of large dissipation. Furthermore, the time-optimal Lyapunov control is investigated to shorten the evolution time and improve the fidelity in open systems.

  19. Multi-fidelity machine learning models for accurate bandgap predictions of solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pilania, Ghanshyam; Gubernatis, James E.; Lookman, Turab

    Here, we present a multi-fidelity co-kriging statistical learning framework that combines variable-fidelity quantum mechanical calculations of bandgaps to generate a machine-learned model that enables low-cost accurate predictions of the bandgaps at the highest fidelity level. Additionally, the adopted Gaussian process regression formulation allows us to predict the underlying uncertainties as a measure of our confidence in the predictions. In using a set of 600 elpasolite compounds as an example dataset and using semi-local and hybrid exchange correlation functionals within density functional theory as two levels of fidelities, we demonstrate the excellent learning performance of the method against actual high fidelitymore » quantum mechanical calculations of the bandgaps. The presented statistical learning method is not restricted to bandgaps or electronic structure methods and extends the utility of high throughput property predictions in a significant way.« less

  20. Multi-fidelity machine learning models for accurate bandgap predictions of solids

    DOE PAGES

    Pilania, Ghanshyam; Gubernatis, James E.; Lookman, Turab

    2016-12-28

    Here, we present a multi-fidelity co-kriging statistical learning framework that combines variable-fidelity quantum mechanical calculations of bandgaps to generate a machine-learned model that enables low-cost accurate predictions of the bandgaps at the highest fidelity level. Additionally, the adopted Gaussian process regression formulation allows us to predict the underlying uncertainties as a measure of our confidence in the predictions. In using a set of 600 elpasolite compounds as an example dataset and using semi-local and hybrid exchange correlation functionals within density functional theory as two levels of fidelities, we demonstrate the excellent learning performance of the method against actual high fidelitymore » quantum mechanical calculations of the bandgaps. The presented statistical learning method is not restricted to bandgaps or electronic structure methods and extends the utility of high throughput property predictions in a significant way.« less

  1. Conceptual design and analysis of a dynamic scale model of the Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Davis, D. A.; Gronet, M. J.; Tan, M. K.; Thorne, J.

    1994-01-01

    This report documents the conceptual design study performed to evaluate design options for a subscale dynamic test model which could be used to investigate the expected on-orbit structural dynamic characteristics of the Space Station Freedom early build configurations. The baseline option was a 'near-replica' model of the SSF SC-7 pre-integrated truss configuration. The approach used to develop conceptual design options involved three sets of studies: evaluation of the full-scale design and analysis databases, conducting scale factor trade studies, and performing design sensitivity studies. The scale factor trade study was conducted to develop a fundamental understanding of the key scaling parameters that drive design, performance and cost of a SSF dynamic scale model. Four scale model options were estimated: 1/4, 1/5, 1/7, and 1/10 scale. Prototype hardware was fabricated to assess producibility issues. Based on the results of the study, a 1/4-scale size is recommended based on the increased model fidelity associated with a larger scale factor. A design sensitivity study was performed to identify critical hardware component properties that drive dynamic performance. A total of 118 component properties were identified which require high-fidelity replication. Lower fidelity dynamic similarity scaling can be used for non-critical components.

  2. Features that contribute to the usefulness of low-fidelity models for surgical skills training.

    PubMed

    Langebæk, R; Berendt, M; Pedersen, L T; Jensen, A L; Eika, B

    2012-04-07

    For practical, ethical and economic reasons, veterinary surgical education is becoming increasingly dependent on models for training. The limited availability and high cost of commercially produced surgical models has increased the need for useful, low-cost alternatives. For this reason, a number of models were developed to be used in a basic surgical skills course for veterinary students. The models were low fidelity, having limited resemblance to real animals. The aim of the present study was to describe the students' learning experience with the models and to report their perception of the usefulness of the models in applying the trained skills to live animal surgery. One hundred and forty-six veterinary fourth-year students evaluated the models on a four-point Likert scale. Of these, 26 additionally participated in individual semistructured interviews. The survey results showed that 75 per cent of the students rated the models 'useful'/'very useful'. Interviews revealed that tactile, dimensional, visual, situational and emotional features are important to students' perception of a successful translation of skills from models to live animal. In conclusion, low-fidelity models are useful educational tools in preparation for live animal surgery. However, there are specific features to take into account when developing models in order for students to perceive them as useful.

  3. Hydropower Optimization Using Artificial Neural Network Surrogate Models of a High-Fidelity Hydrodynamics and Water Quality Model

    NASA Astrophysics Data System (ADS)

    Shaw, Amelia R.; Smith Sawyer, Heather; LeBoeuf, Eugene J.; McDonald, Mark P.; Hadjerioua, Boualem

    2017-11-01

    Hydropower operations optimization subject to environmental constraints is limited by challenges associated with dimensionality and spatial and temporal resolution. The need for high-fidelity hydrodynamic and water quality models within optimization schemes is driven by improved computational capabilities, increased requirements to meet specific points of compliance with greater resolution, and the need to optimize operations of not just single reservoirs but systems of reservoirs. This study describes an important advancement for computing hourly power generation schemes for a hydropower reservoir using high-fidelity models, surrogate modeling techniques, and optimization methods. The predictive power of the high-fidelity hydrodynamic and water quality model CE-QUAL-W2 is successfully emulated by an artificial neural network, then integrated into a genetic algorithm optimization approach to maximize hydropower generation subject to constraints on dam operations and water quality. This methodology is applied to a multipurpose reservoir near Nashville, Tennessee, USA. The model successfully reproduced high-fidelity reservoir information while enabling 6.8% and 6.6% increases in hydropower production value relative to actual operations for dissolved oxygen (DO) limits of 5 and 6 mg/L, respectively, while witnessing an expected decrease in power generation at more restrictive DO constraints. Exploration of simultaneous temperature and DO constraints revealed capability to address multiple water quality constraints at specified locations. The reduced computational requirements of the new modeling approach demonstrated an ability to provide decision support for reservoir operations scheduling while maintaining high-fidelity hydrodynamic and water quality information as part of the optimization decision support routines.

  4. Barriers and enablers to the use of high-fidelity patient simulation manikins in nurse education: an integrative review.

    PubMed

    Al-Ghareeb, Amal Z; Cooper, Simon J

    2016-01-01

    This integrative review identified, critically appraised and synthesised the existing evidence on the barriers and enablers to using high-fidelity human patient simulator manikins (HPSMs) in undergraduate nursing education. In nursing education, specifically at the undergraduate level, a range of low to high-fidelity simulations have been used as teaching aids. However, nursing educators encounter challenges when introducing new teaching methods or technology, despite the prevalence of high-fidelity HPSMs in nursing education. An integrative review adapted a systematic approach. Medline, CINAHL plus, ERIC, PsychINFO, EMBASE, SCOPUS, Science Direct, Cochrane database, Joanna Brigge Institute, ProQuest, California Simulation Alliance, Simulation Innovative Recourses Center and the search engine Google Scholar were searched. Keywords were selected and specific inclusion/exclusion criteria were applied. The review included all research designs for papers published between 2000 and 2015 that identified the barriers and enablers to using high-fidelity HPSMs in undergraduate nursing education. Studies were appraised using the Critical Appraisal Skills Programme criteria. Thematic analysis was undertaken and emergent themes were extracted. Twenty-one studies were included in the review. These studies adopted quasi-experimental, prospective non-experimental and descriptive designs. Ten barriers were identified, including "lack of time," "fear of technology" and "workload issues." Seven enablers were identified, including "faculty training," "administrative support" and a "dedicated simulation coordinator." Barriers to simulation relate specifically to the complex technologies inherent in high-fidelity HPSMs approaches. Strategic approaches that support up-skilling and provide dedicated technological support may overcome these barriers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Hydropower Optimization Using Artificial Neural Network Surrogate Models of a High-Fidelity Hydrodynamics and Water Quality Model

    DOE PAGES

    Shaw, Amelia R.; Sawyer, Heather Smith; LeBoeuf, Eugene J.; ...

    2017-10-24

    Hydropower operations optimization subject to environmental constraints is limited by challenges associated with dimensionality and spatial and temporal resolution. The need for high-fidelity hydrodynamic and water quality models within optimization schemes is driven by improved computational capabilities, increased requirements to meet specific points of compliance with greater resolution, and the need to optimize operations of not just single reservoirs but systems of reservoirs. This study describes an important advancement for computing hourly power generation schemes for a hydropower reservoir using high-fidelity models, surrogate modeling techniques, and optimization methods. The predictive power of the high-fidelity hydrodynamic and water quality model CE-QUAL-W2more » is successfully emulated by an artificial neural network, then integrated into a genetic algorithm optimization approach to maximize hydropower generation subject to constraints on dam operations and water quality. This methodology is applied to a multipurpose reservoir near Nashville, Tennessee, USA. The model successfully reproduced high-fidelity reservoir information while enabling 6.8% and 6.6% increases in hydropower production value relative to actual operations for dissolved oxygen (DO) limits of 5 and 6 mg/L, respectively, while witnessing an expected decrease in power generation at more restrictive DO constraints. Exploration of simultaneous temperature and DO constraints revealed capability to address multiple water quality constraints at specified locations. Here, the reduced computational requirements of the new modeling approach demonstrated an ability to provide decision support for reservoir operations scheduling while maintaining high-fidelity hydrodynamic and water quality information as part of the optimization decision support routines.« less

  6. Utilizing Three-Dimensional Printing Technology to Assess the Feasibility of High-Fidelity Synthetic Ventricular Septal Defect Models for Simulation in Medical Education.

    PubMed

    Costello, John P; Olivieri, Laura J; Krieger, Axel; Thabit, Omar; Marshall, M Blair; Yoo, Shi-Joon; Kim, Peter C; Jonas, Richard A; Nath, Dilip S

    2014-07-01

    The current educational approach for teaching congenital heart disease (CHD) anatomy to students involves instructional tools and techniques that have significant limitations. This study sought to assess the feasibility of utilizing present-day three-dimensional (3D) printing technology to create high-fidelity synthetic heart models with ventricular septal defect (VSD) lesions and applying these models to a novel, simulation-based educational curriculum for premedical and medical students. Archived, de-identified magnetic resonance images of five common VSD subtypes were obtained. These cardiac images were then segmented and built into 3D computer-aided design models using Mimics Innovation Suite software. An Objet500 Connex 3D printer was subsequently utilized to print a high-fidelity heart model for each VSD subtype. Next, a simulation-based educational curriculum using these heart models was developed and implemented in the instruction of 29 premedical and medical students. Assessment of this curriculum was undertaken with Likert-type questionnaires. High-fidelity VSD models were successfully created utilizing magnetic resonance imaging data and 3D printing. Following instruction with these high-fidelity models, all students reported significant improvement in knowledge acquisition (P < .0001), knowledge reporting (P < .0001), and structural conceptualization (P < .0001) of VSDs. It is feasible to use present-day 3D printing technology to create high-fidelity heart models with complex intracardiac defects. Furthermore, this tool forms the foundation for an innovative, simulation-based educational approach to teach students about CHD and creates a novel opportunity to stimulate their interest in this field. © The Author(s) 2014.

  7. Hydropower Optimization Using Artificial Neural Network Surrogate Models of a High-Fidelity Hydrodynamics and Water Quality Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaw, Amelia R.; Sawyer, Heather Smith; LeBoeuf, Eugene J.

    Hydropower operations optimization subject to environmental constraints is limited by challenges associated with dimensionality and spatial and temporal resolution. The need for high-fidelity hydrodynamic and water quality models within optimization schemes is driven by improved computational capabilities, increased requirements to meet specific points of compliance with greater resolution, and the need to optimize operations of not just single reservoirs but systems of reservoirs. This study describes an important advancement for computing hourly power generation schemes for a hydropower reservoir using high-fidelity models, surrogate modeling techniques, and optimization methods. The predictive power of the high-fidelity hydrodynamic and water quality model CE-QUAL-W2more » is successfully emulated by an artificial neural network, then integrated into a genetic algorithm optimization approach to maximize hydropower generation subject to constraints on dam operations and water quality. This methodology is applied to a multipurpose reservoir near Nashville, Tennessee, USA. The model successfully reproduced high-fidelity reservoir information while enabling 6.8% and 6.6% increases in hydropower production value relative to actual operations for dissolved oxygen (DO) limits of 5 and 6 mg/L, respectively, while witnessing an expected decrease in power generation at more restrictive DO constraints. Exploration of simultaneous temperature and DO constraints revealed capability to address multiple water quality constraints at specified locations. Here, the reduced computational requirements of the new modeling approach demonstrated an ability to provide decision support for reservoir operations scheduling while maintaining high-fidelity hydrodynamic and water quality information as part of the optimization decision support routines.« less

  8. Aerodynamic design applying automatic differentiation and using robust variable fidelity optimization

    NASA Astrophysics Data System (ADS)

    Takemiya, Tetsushi

    In modern aerospace engineering, the physics-based computational design method is becoming more important, as it is more efficient than experiments and because it is more suitable in designing new types of aircraft (e.g., unmanned aerial vehicles or supersonic business jets) than the conventional design method, which heavily relies on historical data. To enhance the reliability of the physics-based computational design method, researchers have made tremendous efforts to improve the fidelity of models. However, high-fidelity models require longer computational time, so the advantage of efficiency is partially lost. This problem has been overcome with the development of variable fidelity optimization (VFO). In VFO, different fidelity models are simultaneously employed in order to improve the speed and the accuracy of convergence in an optimization process. Among the various types of VFO methods, one of the most promising methods is the approximation management framework (AMF). In the AMF, objective and constraint functions of a low-fidelity model are scaled at a design point so that the scaled functions, which are referred to as "surrogate functions," match those of a high-fidelity model. Since scaling functions and the low-fidelity model constitutes surrogate functions, evaluating the surrogate functions is faster than evaluating the high-fidelity model. Therefore, in the optimization process, in which gradient-based optimization is implemented and thus many function calls are required, the surrogate functions are used instead of the high-fidelity model to obtain a new design point. The best feature of the AMF is that it may converge to a local optimum of the high-fidelity model in much less computational time than the high-fidelity model. However, through literature surveys and implementations of the AMF, the author xx found that (1) the AMF is very vulnerable when the computational analysis models have numerical noise, which is very common in high-fidelity models, and that (2) the AMF terminates optimization erroneously when the optimization problems have constraints. The first problem is due to inaccuracy in computing derivatives in the AMF, and the second problem is due to erroneous treatment of the trust region ratio, which sets the size of the domain for an optimization in the AMF. In order to solve the first problem of the AMF, automatic differentiation (AD) technique, which reads the codes of analysis models and automatically generates new derivative codes based on some mathematical rules, is applied. If derivatives are computed with the generated derivative code, they are analytical, and the required computational time is independent of the number of design variables, which is very advantageous for realistic aerospace engineering problems. However, if analysis models implement iterative computations such as computational fluid dynamics (CFD), which solves system partial differential equations iteratively, computing derivatives through the AD requires a massive memory size. The author solved this deficiency by modifying the AD approach and developing a more efficient implementation with CFD, and successfully applied the AD to general CFD software. In order to solve the second problem of the AMF, the governing equation of the trust region ratio, which is very strict against the violation of constraints, is modified so that it can accept the violation of constraints within some tolerance. By accepting violations of constraints during the optimization process, the AMF can continue optimization without terminating immaturely and eventually find the true optimum design point. With these modifications, the AMF is referred to as "Robust AMF," and it is applied to airfoil and wing aerodynamic design problems using Euler CFD software. The former problem has 21 design variables, and the latter 64. In both problems, derivatives computed with the proposed AD method are first compared with those computed with the finite differentiation (FD) method, and then, the Robust AMF is implemented along with the sequential quadratic programming (SQP) optimization method with only high-fidelity models. The proposed AD method computes derivatives more accurately and faster than the FD method, and the Robust AMF successfully optimizes shapes of the airfoil and the wing in a much shorter time than SQP with only high-fidelity models. These results clearly show the effectiveness of the Robust AMF. Finally, the feasibility of reducing computational time for calculating derivatives and the necessity of AMF with an optimum design point always in the feasible region are discussed as future work.

  9. Measurement of carbon condensates using small-angle x-ray scattering during detonation of the high explosive hexanitrostilbene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagge-Hansen, M.; Lauderbach, L.; Hodgin, R.

    2015-06-28

    The dynamics of carbon condensation in detonating high explosives remains controversial. Detonation model validation requires data for processes occurring at nanometer length scales on time scales ranging from nanoseconds to microseconds. A new detonation endstation has been commissioned to acquire and provide time-resolved small-angle x-ray scattering (SAXS) from detonating explosives. Hexanitrostilbene (HNS) was selected as the first to investigate due to its ease of initiation using exploding foils and flyers, vacuum compatibility, high thermal stability, and stoichiometric carbon abundance that produces high carbon condensate yields. The SAXS data during detonation, collected with 300 ns time resolution, provide unprecedented signal fidelity overmore » a broad q-range. This fidelity permits the first analysis of both the Guinier and Porod/power-law regions of the scattering profile during detonation, which contains information about the size and morphology of the resultant carbon condensate nanoparticles. To bolster confidence in these data, the scattering angle and intensity were additionally cross-referenced with a separate, highly calibrated SAXS beamline. The data show that HNS produces carbon particles with a radius of gyration of 2.7 nm in less than 400 ns after the detonation front has passed, and this size and morphology are constant over the next several microseconds. These data directly contradict previous pioneering work on RDX/TNT mixtures and TATB, where observations indicate significant particle growth (50% or more) continues over several microseconds. The power-law slope is about −3, which is consistent with a complex disordered, irregular, or folded sp{sup 2} sub-arrangement within a relatively monodisperse structure possessing radius of gyration of 2.7 nm after the detonation of HNS.« less

  10. Measurement of carbon condensation using small-angle x-ray scattering during detonation of the high explosive hexanitrostilbene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagge-Hansen, M.; Lauderbach, L. M.; Hodgin, R.

    2015-06-24

    The dynamics of carboncondensation in detonating high explosives remains controversial. Detonation model validation requires data for processes occurring at nanometer length scales on time scales ranging from nanoseconds to microseconds. A new detonation endstation has been commissioned to acquire and provide time-resolved small-angle x-ray scattering (SAXS) from detonating explosives. Hexanitrostilbene (HNS) was selected as the first to investigate due to its ease of initiation using exploding foils and flyers, vacuum compatibility, high thermal stability, and stoichiometric carbon abundance that produces high carbon condensate yields. The SAXS data during detonation, collected with 300 ns time resolution, provide unprecedented signal fidelity overmore » a broad q-range. This fidelity permits the first analysis of both the Guinier and Porod/power-law regions of the scattering profile during detonation, which contains information about the size and morphology of the resultant carbon condensate nanoparticles. To bolster confidence in these data, the scattering angle and intensity were additionally cross-referenced with a separate, highly calibrated SAXS beamline. The data show that HNS produces carbon particles with a radius of gyration of 2.7 nm in less than 400 ns after the detonation front has passed, and this size and morphology are constant over the next several microseconds. These data directly contradict previous pioneering work on RDX/TNT mixtures and TATB, where observations indicate significant particle growth (50% or more) continues over several microseconds. As a result, the power-law slope is about –3, which is consistent with a complex disordered, irregular, or folded sp 2 sub-arrangement within a relatively monodisperse structure possessing radius of gyration of 2.7 nm after the detonation of HNS.« less

  11. Measurement of carbon condensates using small-angle x-ray scattering during detonation of the high explosive hexanitrostilbene

    DOE PAGES

    Bagge-Hansen, M.; Lauderbach, L.; Hodgin, R.; ...

    2015-06-24

    In this study, the dynamics of carbon condensation in detonating high explosives remains controversial. Detonation model validation requires data for processes occurring at nanometer length scales on time scales ranging from nanoseconds to microseconds. A new detonation end station has been commissioned to acquire and provide time-resolved small-angle x-ray scattering (SAXS) from detonating explosives. Hexanitrostilbene (HNS) was selected as the first to investigate due to its ease of initiation using exploding foils and flyers, vacuum compatibility, high thermal stability, and stoichiometric carbon abundance that produces high carbon condensate yields. The SAXS data during detonation, collected with 300 ns time resolution,more » provide unprecedented signal fidelity over a broad q-range. This fidelity permits the first analysis of both the Guinier and Porod/power-law regions of the scattering profile during detonation, which contains information about the size and morphology of the resultant carbon condensate nanoparticles. To bolster confidence in these data, the scattering angle and intensity were additionally cross-referenced with a separate, highly calibrated SAXS beamline. The data show that HNS produces carbon particles with a radius of gyration of 2.7 nm in less than 400 ns after the detonation front has passed, and this size and morphology are constant over the next several microseconds. These data directly contradict previous pioneering work on RDX/TNT mixtures and TATB, where observations indicate significant particle growth (50% or more) continues over several microseconds. The power-law slope is about -3, which is consistent with a complex disordered, irregular, or folded sp 2 sub-arrangement within a relatively monodisperse structure possessing radius of gyration of 2.7 nm after the detonation of HNS.« less

  12. Acknowledging selection at sub-organismal levels resolves controversy on pro-cooperation mechanisms

    PubMed Central

    Shou, Wenying

    2015-01-01

    Cooperators who pay a cost to produce publically-available benefits can be exploited by cheaters who do not contribute fairly. How might cooperation persist against cheaters? Two classes of mechanisms are known to promote cooperation: 'partner choice', where a cooperator preferentially interacts with cooperative over cheating partners; and 'partner fidelity feedback', where repeated interactions between individuals ensure that cheaters suffer as their cooperative partners languish (see, for example, Momeni et al., 2013). However when both mechanisms can act, differentiating them has generated controversy. Here, I resolve this controversy by noting that selection can operate on organismal and sub-organismal 'entities' such that partner fidelity feedback at sub-organismal level can appear as partner choice at organismal level. I also show that cooperation between multicellular eukaryotes and mitochondria is promoted by partner fidelity feedback and partner choice between sub-organismal entities, in addition to being promoted by partner fidelity feedback between hosts and symbionts, as was previously known. DOI: http://dx.doi.org/10.7554/eLife.10106.001 PMID:26714105

  13. Demonstration of a quantum controlled-NOT gate in the telecommunications band.

    PubMed

    Chen, Jun; Altepeter, Joseph B; Medic, Milja; Lee, Kim Fook; Gokden, Burc; Hadfield, Robert H; Nam, Sae Woo; Kumar, Prem

    2008-04-04

    We present the first quantum controlled-not (cnot) gate realized using a fiber-based indistinguishable photon-pair source in the 1.55 microm telecommunications band. Using this free-space cnot gate, all four Bell states are produced and fully characterized by performing quantum-state tomography, demonstrating the gate's unambiguous entangling capability and high fidelity. Telecom-band operation makes this cnot gate particularly suitable for quantum-information-processing tasks that are at the interface of quantum communication and linear optical quantum computing.

  14. State resolved vibrational relaxation modeling for strongly nonequilibrium flows

    NASA Astrophysics Data System (ADS)

    Boyd, Iain D.; Josyula, Eswar

    2011-05-01

    Vibrational relaxation is an important physical process in hypersonic flows. Activation of the vibrational mode affects the fundamental thermodynamic properties and finite rate relaxation can reduce the degree of dissociation of a gas. Low fidelity models of vibrational activation employ a relaxation time to capture the process at a macroscopic level. High fidelity, state-resolved models have been developed for use in continuum gas dynamics simulations based on computational fluid dynamics (CFD). By comparison, such models are not as common for use with the direct simulation Monte Carlo (DSMC) method. In this study, a high fidelity, state-resolved vibrational relaxation model is developed for the DSMC technique. The model is based on the forced harmonic oscillator approach in which multi-quantum transitions may become dominant at high temperature. Results obtained for integrated rate coefficients from the DSMC model are consistent with the corresponding CFD model. Comparison of relaxation results obtained with the high-fidelity DSMC model shows significantly less excitation of upper vibrational levels in comparison to the standard, lower fidelity DSMC vibrational relaxation model. Application of the new DSMC model to a Mach 7 normal shock wave in carbon monoxide provides better agreement with experimental measurements than the standard DSMC relaxation model.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong Yuli; Zou Xubo; Guo Guangcan

    We investigate the economical Gaussian cloning of coherent states with the known phase, which produces M copies from N input replica and can be implemented with degenerate parametric amplifiers and beam splitters.The achievable fidelity of single copy is given by 2M{radical}(N)/[{radical}(N)(M-1)+{radical}((1+N)(M{sup 2}+N))], which is bigger than the optimal fidelity of the universal Gaussian cloning. The cloning machine presented here works without ancillary optical modes and can be regarded as the continuous variable generalization of the economical cloning machine for qudits.

  16. Development of Predictive Energy Management Strategies for Hybrid Electric Vehicles

    NASA Astrophysics Data System (ADS)

    Baker, David

    Studies have shown that obtaining and utilizing information about the future state of vehicles can improve vehicle fuel economy (FE). However, there has been a lack of research into the impact of real-world prediction error on FE improvements, and whether near-term technologies can be utilized to improve FE. This study seeks to research the effect of prediction error on FE. First, a speed prediction method is developed, and trained with real-world driving data gathered only from the subject vehicle (a local data collection method). This speed prediction method informs a predictive powertrain controller to determine the optimal engine operation for various prediction durations. The optimal engine operation is input into a high-fidelity model of the FE of a Toyota Prius. A tradeoff analysis between prediction duration and prediction fidelity was completed to determine what duration of prediction resulted in the largest FE improvement. Results demonstrate that 60-90 second predictions resulted in the highest FE improvement over the baseline, achieving up to a 4.8% FE increase. A second speed prediction method utilizing simulated vehicle-to-vehicle (V2V) communication was developed to understand if incorporating near-term technologies could be utilized to further improve prediction fidelity. This prediction method produced lower variation in speed prediction error, and was able to realize a larger FE improvement over the local prediction method for longer prediction durations, achieving up to 6% FE improvement. This study concludes that speed prediction and prediction-informed optimal vehicle energy management can produce FE improvements with real-world prediction error and drive cycle variability, as up to 85% of the FE benefit of perfect speed prediction was achieved with the proposed prediction methods.

  17. Effects of Low- Versus High-Fidelity Simulations on the Cognitive Burden and Performance of Entry-Level Paramedicine Students: A Mixed-Methods Comparison Trial Using Eye-Tracking, Continuous Heart Rate, Difficulty Rating Scales, Video Observation and Interviews.

    PubMed

    Mills, Brennen W; Carter, Owen B-J; Rudd, Cobie J; Claxton, Louise A; Ross, Nathan P; Strobel, Natalie A

    2016-02-01

    High-fidelity simulation-based training is often avoided for early-stage students because of the assumption that while practicing newly learned skills, they are ill suited to processing multiple demands, which can lead to "cognitive overload" and poorer learning outcomes. We tested this assumption using a mixed-methods experimental design manipulating psychological immersion. Thirty-nine randomly assigned first-year paramedicine students completed low- or high-environmental fidelity simulations [low-environmental fidelity simulations (LF(en)S) vs. high-environmental fidelity simulation (HF(en)S)] involving a manikin with obstructed airway (SimMan3G). Psychological immersion and cognitive burden were determined via continuous heart rate, eye tracking, self-report questionnaire (National Aeronautics and Space Administration Task Load Index), independent observation, and postsimulation interviews. Performance was assessed by successful location of obstruction and time-to-termination. Eye tracking confirmed that students attended to multiple, concurrent stimuli in HF(en)S and interviews consistently suggested that they experienced greater psychological immersion and cognitive burden than their LF(en)S counterparts. This was confirmed by significantly higher mean heart rate (P < 0.001) and National Aeronautics and Space Administration Task Load Index mental demand (P < 0.05). Although group allocation did not influence the proportion of students who ultimately revived the patient (58% vs. 30%, P < 0.10), the HF(en)S students did so significantly more quickly (P < 0.01). The LF(en)S students had low immersion resulting in greater assessment anxiety. High-environmental fidelity simulation engendered immersion and a sense of urgency in students, whereas LF(en)S created assessment anxiety and slower performance. We conclude that once early-stage students have learned the basics of a clinical skill, throwing them in the "deep end" of high-fidelity simulation creates significant additional cognitive burden but this has considerable educational merit.

  18. Final Environmental Assessment for the Installation of New JDAM and High Fidelity Targets for the Nevada Test and Training Range

    DTIC Science & Technology

    2004-11-01

    Target Centroid 98 RANW / R SC GIS 04071 Data valid as of 11 Mar 04 rogertargets_a#2.apr Figure 2-3. Chemical/Industrial and High Fidelity Urban...existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding...Fidelity Targets, NTTR Nevada Division of Wildlife – Nevada Test and Training Range JDAM Targets Nevada Natural Heritage Program – Data Request received 8

  19. High-fidelity frequency down-conversion of visible entangled photon pairs with superconducting single-photon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikuta, Rikizo; Kato, Hiroshi; Kusaka, Yoshiaki

    We experimentally demonstrate a high-fidelity visible-to-telecommunicationwavelength conversion of a photon by using a solid-state-based difference frequency generation. In the experiment, one half of a pico-second visible entangled photon pair at 780 nm is converted to a 1522-nm photon. Using superconducting single-photon detectors with low dark count rates and small timing jitters, we observed a fidelity of 0.93±0.04 after the wavelength conversion.

  20. Comparison of intervention fidelity between COPE TEEN and an attention-control program in a randomized controlled trial

    PubMed Central

    Kelly, Stephanie A.; Oswalt, Krista; Melnyk, Bernadette Mazurek; Jacobson, Diana

    2015-01-01

    Fidelity in implementing an intervention is critical to accurately determine and interpret the effects of an intervention. It is important to monitor the manner in which the behavioral intervention is implemented (e.g. adaptations, delivery as intended and dose). Few interventions are implemented with 100% fidelity. In this study, high school health teachers implemented the intervention. To attribute study findings to the intervention, it was vital to know to what degree the intervention was implemented. Therefore, the purposes of this study were to evaluate intervention fidelity and to compare implementation fidelity between the creating opportunities for personal empowerment (COPE) Healthy Lifestyles TEEN (thinking, emotions, exercise, and nutrition) program, the experimental intervention and Healthy Teens, an attention-control intervention, in a randomized controlled trial with 779 adolescents from 11 high schools in the southwest region of the United States. Thirty teachers participated in this study. Findings indicated that the attention-control teachers implemented their intervention with greater fidelity than COPE TEEN teachers. It is possible due to the novel intervention and the teachers’ unfamiliarity with cognitive-behavioral skills building, COPE TEEN teachers had less fidelity. It is important to assess novel skill development prior to the commencement of experimental interventions and to provide corrective feedback during the course of implementation. PMID:25355179

  1. Orbit Stability of OSIRIS-REx in the Vicinity of Bennu Using a High-Fidelity Solar Radiation Model

    NASA Technical Reports Server (NTRS)

    Williams, Trevor; Hughes, Kyle; Mashiku, Alinda; Longuski, James

    2015-01-01

    The OSIRIS-REx mission (Origins Spectral Interpretation Resource Identification Security Regolith EXPlorer) is an asteroid sample return mission to Bennu (RQ36) that is scheduled to launch in 2016. The planned science operations precluding the small retrieval involve operations in terminator orbits (orbit plane is perpendicular to the sun). Over longer durations the solar radiation pressure (SRP) perturbs the orbit causing it to precess. Our work involves: modeling high fidelity SRP model to capture the perturbations during attitude changes; design a stable orbit from the high fidelity models to analyze the stability over time.

  2. Lattice Boltzmann for Airframe Noise Predictions

    NASA Technical Reports Server (NTRS)

    Barad, Michael; Kocheemoolayil, Joseph; Kiris, Cetin

    2017-01-01

    Increase predictive use of High-Fidelity Computational Aero- Acoustics (CAA) capabilities for NASA's next generation aviation concepts. CFD has been utilized substantially in analysis and design for steady-state problems (RANS). Computational resources are extremely challenged for high-fidelity unsteady problems (e.g. unsteady loads, buffet boundary, jet and installation noise, fan noise, active flow control, airframe noise, etc) ü Need novel techniques for reducing the computational resources consumed by current high-fidelity CAA Need routine acoustic analysis of aircraft components at full-scale Reynolds number from first principles Need an order of magnitude reduction in wall time to solution!

  3. Testing the Predictive Capability of the High-Fidelity Generalized Method of Cells Using an Efficient Reformulation

    NASA Technical Reports Server (NTRS)

    Arnold, Steven M. (Technical Monitor); Bansal, Yogesh; Pindera, Marek-Jerzy

    2004-01-01

    The High-Fidelity Generalized Method of Cells is a new micromechanics model for unidirectionally reinforced periodic multiphase materials that was developed to overcome the original model's shortcomings. The high-fidelity version predicts the local stress and strain fields with dramatically greater accuracy relative to the original model through the use of a better displacement field representation. Herein, we test the high-fidelity model's predictive capability in estimating the elastic moduli of periodic composites characterized by repeating unit cells obtained by rotation of an infinite square fiber array through an angle about the fiber axis. Such repeating unit cells may contain a few or many fibers, depending on the rotation angle. In order to analyze such multi-inclusion repeating unit cells efficiently, the high-fidelity micromechanics model's framework is reformulated using the local/global stiffness matrix approach. The excellent agreement with the corresponding results obtained from the standard transformation equations confirms the new model's predictive capability for periodic composites characterized by multi-inclusion repeating unit cells lacking planes of material symmetry. Comparison of the effective moduli and local stress fields with the corresponding results obtained from the original Generalized Method of Cells dramatically highlights the original model's shortcomings for certain classes of unidirectional composites.

  4. High fidelity quasi steady-state aerodynamic model effects on race vehicle performance predictions using multi-body simulation

    NASA Astrophysics Data System (ADS)

    Mohrfeld-Halterman, J. A.; Uddin, M.

    2016-07-01

    We described in this paper the development of a high fidelity vehicle aerodynamic model to fit wind tunnel test data over a wide range of vehicle orientations. We also present a comparison between the effects of this proposed model and a conventional quasi steady-state aerodynamic model on race vehicle simulation results. This is done by implementing both of these models independently in multi-body quasi steady-state simulations to determine the effects of the high fidelity aerodynamic model on race vehicle performance metrics. The quasi steady state vehicle simulation is developed with a multi-body NASCAR Truck vehicle model, and simulations are conducted for three different types of NASCAR race tracks, a short track, a one and a half mile intermediate track, and a higher speed, two mile intermediate race track. For each track simulation, the effects of the aerodynamic model on handling, maximum corner speed, and drive force metrics are analysed. The accuracy of the high-fidelity model is shown to reduce the aerodynamic model error relative to the conventional aerodynamic model, and the increased accuracy of the high fidelity aerodynamic model is found to have realisable effects on the performance metric predictions on the intermediate tracks resulting from the quasi steady-state simulation.

  5. Feasibility and fidelity of practising surgical fixation on a virtual ulna bone

    PubMed Central

    LeBlanc, Justin; Hutchison, Carol; Hu, Yaoping; Donnon, Tyrone

    2013-01-01

    Background Surgical simulators provide a safe environment to learn and practise psychomotor skills. A goal for these simulators is to achieve high levels of fidelity. The purpose of this study was to develop a reliable surgical simulator fidelity questionnaire and to assess whether a newly developed virtual haptic simulator for fixation of an ulna has comparable levels of fidelity as Sawbones. Methods Simulator fidelity questionnaires were developed. We performed a stratified randomized study with surgical trainees. They performed fixation of the ulna using a virtual simulator and Sawbones. They completed the fidelity questionnaires after each procedure. Results Twenty-two trainees participated in the study. The reliability of the fidelity questionnaire for each separate domain (environment, equipment, psychological) was Cronbach α greater than 0.70, except for virtual environment. The Sawbones had significantly higher levels of fidelity than the virtual simulator (p < 0.001) with a large effect size difference (Cohen d < 1.3). Conclusion The newly developed fidelity questionnaire is a reliable tool that can potentially be used to determine the fidelity of other surgical simulators. Increasing the fidelity of this virtual simulator is required before its use as a training tool for surgical fixation. The virtual simulator brings with it the added benefits of repeated, independent safe use with immediate, objective feedback and the potential to alter the complexity of the skill. PMID:23883510

  6. On the mutagenicity of homologous recombination and double-strand break repair in bacteriophage.

    PubMed

    Shcherbakov, Victor P; Plugina, Lidiya; Shcherbakova, Tamara; Sizova, Svetlana; Kudryashova, Elena

    2011-01-02

    The double-strand break (DSB) repair via homologous recombination is generally construed as a high-fidelity process. However, some molecular genetic observations show that the recombination and the recombinational DSB repair may be mutagenic and even highly mutagenic. Here we developed an effective and precise method for studying the fidelity of DSB repair in vivo by combining DSBs produced site-specifically by the SegC endonuclease with the famous advantages of the recombination analysis of bacteriophage T4 rII mutants. The method is based on the comparison of the rate of reversion of rII mutation in the presence and in the absence of a DSB repair event initiated in the proximity of the mutation. We observed that DSB repair may moderately (up to 6-fold) increase the apparent reversion frequency, the effect of being dependent on the mutation structure. We also studied the effect of the T4 recombinase deficiency (amber mutation in the uvsX gene) on the fidelity of DSB repair. We observed that DSBs are still repaired via homologous recombination in the uvsX mutants, and the apparent fidelity of this repair is higher than that seen in the wild-type background. The mutator effect of the DSB repair may look unexpected given that most of the normal DNA synthesis in bacteriophage T4 is performed via a recombination-dependent replication (RDR) pathway, which is thought to be indistinguishable from DSB repair. There are three possible explanations for the observed mutagenicity of DSB repair: (1) the origin-dependent (early) DNA replication may be more accurate than the RDR; (2) the step of replication initiation may be more mutagenic than the process of elongation; and (3) the apparent mutagenicity may just reflect some non-randomness in the pool of replicating DNA, i.e., preferential replication of the sequences already involved in replication. We discuss the DSB repair pathway in the absence of UvsX recombinase. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. A High-Fidelity Simulation of a Generic Commercial Aircraft Engine and Controller

    NASA Technical Reports Server (NTRS)

    May, Ryan D.; Csank, Jeffrey; Lavelle, Thomas M.; Litt, Jonathan S.; Guo, Ten-Huei

    2010-01-01

    A new high-fidelity simulation of a generic 40,000 lb thrust class commercial turbofan engine with a representative controller, known as CMAPSS40k, has been developed. Based on dynamic flight test data of a highly instrumented engine and previous engine simulations developed at NASA Glenn Research Center, this non-proprietary simulation was created especially for use in the development of new engine control strategies. C-MAPSS40k is a highly detailed, component-level engine model written in MATLAB/Simulink (The MathWorks, Inc.). Because the model is built in Simulink, users have the ability to use any of the MATLAB tools for analysis and control system design. The engine components are modeled in C-code, which is then compiled to allow faster-than-real-time execution. The engine controller is based on common industry architecture and techniques to produce realistic closed-loop transient responses while ensuring that no safety or operability limits are violated. A significant feature not found in other non-proprietary models is the inclusion of transient stall margin debits. These debits provide an accurate accounting of the compressor surge margin, which is critical in the design of an engine controller. This paper discusses the development, characteristics, and capabilities of the C-MAPSS40k simulation

  8. Different rates of spontaneous mutation of chloroplastic and nuclear viroids as determined by high-fidelity ultra-deep sequencing.

    PubMed

    López-Carrasco, Amparo; Ballesteros, Cristina; Sentandreu, Vicente; Delgado, Sonia; Gago-Zachert, Selma; Flores, Ricardo; Sanjuán, Rafael

    2017-09-01

    Mutation rates vary by orders of magnitude across biological systems, being higher for simpler genomes. The simplest known genomes correspond to viroids, subviral plant replicons constituted by circular non-coding RNAs of few hundred bases. Previous work has revealed an extremely high mutation rate for chrysanthemum chlorotic mottle viroid, a chloroplast-replicating viroid. However, whether this is a general feature of viroids remains unclear. Here, we have used high-fidelity ultra-deep sequencing to determine the mutation rate in a common host (eggplant) of two viroids, each representative of one family: the chloroplastic eggplant latent viroid (ELVd, Avsunviroidae) and the nuclear potato spindle tuber viroid (PSTVd, Pospiviroidae). This revealed higher mutation frequencies in ELVd than in PSTVd, as well as marked differences in the types of mutations produced. Rates of spontaneous mutation, quantified in vivo using the lethal mutation method, ranged from 1/1000 to 1/800 for ELVd and from 1/7000 to 1/3800 for PSTVd depending on sequencing run. These results suggest that extremely high mutability is a common feature of chloroplastic viroids, whereas the mutation rates of PSTVd and potentially other nuclear viroids appear significantly lower and closer to those of some RNA viruses.

  9. Different rates of spontaneous mutation of chloroplastic and nuclear viroids as determined by high-fidelity ultra-deep sequencing

    PubMed Central

    Ballesteros, Cristina; Sentandreu, Vicente; Gago-Zachert, Selma

    2017-01-01

    Mutation rates vary by orders of magnitude across biological systems, being higher for simpler genomes. The simplest known genomes correspond to viroids, subviral plant replicons constituted by circular non-coding RNAs of few hundred bases. Previous work has revealed an extremely high mutation rate for chrysanthemum chlorotic mottle viroid, a chloroplast-replicating viroid. However, whether this is a general feature of viroids remains unclear. Here, we have used high-fidelity ultra-deep sequencing to determine the mutation rate in a common host (eggplant) of two viroids, each representative of one family: the chloroplastic eggplant latent viroid (ELVd, Avsunviroidae) and the nuclear potato spindle tuber viroid (PSTVd, Pospiviroidae). This revealed higher mutation frequencies in ELVd than in PSTVd, as well as marked differences in the types of mutations produced. Rates of spontaneous mutation, quantified in vivo using the lethal mutation method, ranged from 1/1000 to 1/800 for ELVd and from 1/7000 to 1/3800 for PSTVd depending on sequencing run. These results suggest that extremely high mutability is a common feature of chloroplastic viroids, whereas the mutation rates of PSTVd and potentially other nuclear viroids appear significantly lower and closer to those of some RNA viruses. PMID:28910391

  10. Applying the Five-Step Model of Fidelity Assessment to a Randomized Experiment of a High School STEM Intervention

    ERIC Educational Resources Information Center

    Kopp, Jason P.; Hulleman, Chris S.; Harackiewicz, Judith M.; Rozek, Chris

    2012-01-01

    Assessing fidelity of implementation is becoming increasingly important in education research, in particular as a tool for understanding variations in treatment effectiveness. Fidelity of implementation is defined as "the determination of how well an intervention is implemented in comparison with the original program design during an efficacy…

  11. Rapid one-step recombinational cloning

    PubMed Central

    Fu, Changlin; Wehr, Daniel R.; Edwards, Janice; Hauge, Brian

    2008-01-01

    As an increasing number of genes and open reading frames of unknown function are discovered, expression of the encoded proteins is critical toward establishing function. Accordingly, there is an increased need for highly efficient, high-fidelity methods for directional cloning. Among the available methods, site-specific recombination-based cloning techniques, which eliminate the use of restriction endonucleases and ligase, have been widely used for high-throughput (HTP) procedures. We have developed a recombination cloning method, which uses truncated recombination sites to clone PCR products directly into destination/expression vectors, thereby bypassing the requirement for first producing an entry clone. Cloning efficiencies in excess of 80% are obtained providing a highly efficient method for directional HTP cloning. PMID:18424799

  12. Prospective randomized comparison of standard didactic lecture versus high-fidelity simulation for radiology resident contrast reaction management training.

    PubMed

    Wang, Carolyn L; Schopp, Jennifer G; Petscavage, Jonelle M; Paladin, Angelisa M; Richardson, Michael L; Bush, William H

    2011-06-01

    The objective of our study was to assess whether high-fidelity simulation-based training is more effective than traditional didactic lecture to train radiology residents in the management of contrast reactions. This was a prospective study of 44 radiology residents randomized into a simulation group versus a lecture group. All residents attended a contrast reaction didactic lecture. Four months later, baseline knowledge was assessed with a written test, which we refer to as the "pretest." After the pretest, the 21 residents in the lecture group attended a repeat didactic lecture and the 23 residents in the simulation group underwent high-fidelity simulation-based training with five contrast reaction scenarios. Next, all residents took a second written test, which we refer to as the "posttest." Two months after the posttest, both groups took a third written test, which we refer to as the "delayed posttest," and underwent performance testing with a high-fidelity severe contrast reaction scenario graded on predefined critical actions. There was no statistically significant difference between the simulation and lecture group pretest, immediate posttest, or delayed posttest scores. The simulation group performed better than the lecture group on the severe contrast reaction simulation scenario (p = 0.001). The simulation group reported improved comfort in identifying and managing contrast reactions and administering medications after the simulation training (p ≤ 0.04) and was more comfortable than the control group (p = 0.03), which reported no change in comfort level after the repeat didactic lecture. When compared with didactic lecture, high-fidelity simulation-based training of contrast reaction management shows equal results on written test scores but improved performance during a high-fidelity severe contrast reaction simulation scenario.

  13. High-Fidelity Simulation Meets Athletic Training Education: An Innovative Collaborative Teaching Project

    ERIC Educational Resources Information Center

    Palmer, Elizabeth; Edwards, Taylor; Racchini, James

    2014-01-01

    High-fidelity simulation is frequently used in nursing education to provide students with simulated experiences prior to and throughout clinical coursework that involves direct patient care. These high-tech exercises take advantage of the benefits of a standardized patient or mock patient encounter, while eliminating some of the drawbacks…

  14. Assessing the link between implementation fidelity and health outcomes for a trial of intensive case management by community health workers: a mixed methods study protocol.

    PubMed

    Schmidt, Barbara; Watt, Kerrianne; McDermott, Robyn; Mills, Jane

    2017-07-17

    Better systems of care are required to address chronic disease in Indigenous people to ensure they can access all their care needs. Health research has produced evidence about effective models of care and chronic disease strategies to address Indigenous health, however the transfer of research findings into routine clinical practice has proven challenging. Complex interventions, such as those related to chronic disease, have many components that are often poorly implemented and hence rarely achieve implementation fidelity. Implementation fidelity is "the degree to which programs are implemented as intended by the program developer". Knowing if an intervention was implemented as planned is fundamental to knowing what has contributed to the success of an intervention. The aim of this study is to adapt the implementation fidelity framework developed by Keith et al. and apply it to the intervention implemented in phase 1 of the Getting Better at Chronic Care in North Queensland study. The objectives are to quantify the level of implementation fidelity achieved during phase 1 of the study, measure the association between implementation fidelity and health outcomes and to explore the features of the primary health care system that contributed to improved health outcomes. A convergent parallel mixed methods study design will be used to develop a process for assessing implementation fidelity. Information collected via a questionnaire and routine data generated during phase 1 of the study will be used to explain the context for the intervention in each site and develop an implementation fidelity score for each component of the intervention. A weighting will be applied to each component of the intervention to calculate the overall implementation score for each participating community. Statistical analysis will assess the level of association between implementation fidelity scores and health outcomes. Health services research seeks to find solutions to social and technical problems to improve health outcomes. The development of a tool and methodology for assessing implementation fidelity in the Indigenous primary health care context will help address some of the barriers to the translation of research into practice. ACTRN12610000812099 : 29.9.2010.

  15. High fidelity quantum teleportation assistance with quantum neural network

    NASA Astrophysics Data System (ADS)

    Huang, Chunhui; Wu, Bichun

    2014-09-01

    In this paper, a high fidelity scheme of quantum teleportation based on quantum neural network (QNN) is proposed. The QNN is composed of multi-bit control-not gates. The quantum teleportation of a qubit state via two-qubit entangled channels is investigated by solving the master equation in Lindblad operators with a noisy environment. To ensure the security of quantum teleportation, the indirect training of QNN is employed. Only 10% of teleported information is extracted for the training of QNN parameters. Then the outputs are corrected by the other QNN at Bob's side. We build a random series of numbers ranged in [0, π] as inputs and simulate the properties of our teleportation scheme. The results show that the fidelity of quantum teleportation system is significantly improved to approach 1 by the error-correction of QNN. It illustrates that the distortion can be eliminated perfectly and the high fidelity of quantum teleportation could be implemented.

  16. High-fidelity quantum gates on quantum-dot-confined electron spins in low-Q optical microcavities

    NASA Astrophysics Data System (ADS)

    Li, Tao; Gao, Jian-Cun; Deng, Fu-Guo; Long, Gui-Lu

    2018-04-01

    We propose some high-fidelity quantum circuits for quantum computing on electron spins of quantum dots (QD) embedded in low-Q optical microcavities, including the two-qubit controlled-NOT gate and the multiple-target-qubit controlled-NOT gate. The fidelities of both quantum gates can, in principle, be robust to imperfections involved in a practical input-output process of a single photon by converting the infidelity into a heralded error. Furthermore, the influence of two different decay channels is detailed. By decreasing the quality factor of the present microcavity, we can largely increase the efficiencies of these quantum gates while their high fidelities remain unaffected. This proposal also has another advantage regarding its experimental feasibility, in that both quantum gates can work faithfully even when the QD-cavity systems are non-identical, which is of particular importance in current semiconductor QD technology.

  17. Site fidelity, mate fidelity, and breeding dispersal in American kestrels

    USGS Publications Warehouse

    Steenhof, K.; Peterson, B.E.

    2009-01-01

    We assessed mate fidelity, nest-box fidelity, and breeding dispersal distances of American Kestrels (falco sparverius) nesting in boxes in southwestern Idaho from 1990 through 2006. Seventy-seven percent of boxes had different males and 87% had different females where nest-box occupants were identified in consecutive years. High turnover rates were partly a result of box-switching. Forty-eight percent of males and 58% of females that nested within the study area in successive years used different boxes. The probability of changing boxes was unrelated to gender, nesting success in the prior year, or years of nesting experience. Breeding dispersal distances for birds that moved to different boxes averaged 2.2 km for males (max = 22 km) and 3.2 km for females (max = 32 km). Approximately 70% of birds that nested in consecutive years on the study area had a different mate in the second year. Mate fidelity was related to box fidelity but not to prior nesting success or years of nesting experience. Mate changes occurred 32% of the time when the previous mate was known to be alive and nesting in the area. Kestrels that switched mates and boxes did not improve or decrease their subsequent nesting success. Kestrels usually switched to mates with less experience and lower lifetime productivity than their previous mates. The costs of switching boxes and mates were low, and there were no obvious benefits to fidelity. The cost of "waiting" for a previous mate that might have died could be high in species with high annual mortality.

  18. Training for shoulder dystocia: a trial of simulation using low-fidelity and high-fidelity mannequins.

    PubMed

    Crofts, Joanna F; Bartlett, Christine; Ellis, Denise; Hunt, Linda P; Fox, Robert; Draycott, Timothy J

    2006-12-01

    To evaluate the effectiveness of simulation training for shoulder dystocia management and compare training using a high-fidelity mannequin with that using traditional devices. Training was undertaken in six hospitals and a medical simulation center in the United Kingdom. Midwives and obstetricians working for participating hospitals were eligible for inclusion. One hundred forty participants (45 doctors, 95 midwives) were randomized to training with a high-fidelity training mannequin (incorporating force perception training) or traditional low-fidelity mannequins. Performance was assessed pre- and posttraining, using a videoed, standardized shoulder dystocia simulation. Outcome measures were delivery, head-to-body delivery time, use of appropriate and inappropriate actions, force applied, and communication. One hundred thirty-two participants completed the posttraining assessment. All training was associated with improved performance: use of basic maneuvers 114 of 140 (81.4%) to 125 of 132 (94.7%) (P=.002), successful deliveries 60 of 140 (42.9%) to 110 of 132 (83.3%) (P<.001), good communication with the patient 79 of 139 (56.8%) to 109 of 132 (82.6%) (P<.001), pre- and posttraining, respectively. Training with the high-fidelity mannequin was associated with a higher successful delivery rate than training with traditional devices: 94% compared with 72% (odds ratio 6.53, 95% confidence interval 2.05-20.81; P=.002). Total applied force was significantly lower for those who had undergone force training (2,030 Newton seconds versus 2,916 Newton seconds; P=.006) but there was no significant difference in the peak applied force 102 Newtons versus 112 Newtons (P=.242). This study verifies the need for shoulder dystocia training; before training only 43% participants could achieve delivery. All training with mannequins improved the management of simulated shoulder dystocia. Training on a high-fidelity mannequin, including force perception teaching, offered additional training benefits. I.

  19. Progress in the Utilization of High-Fidelity Simulation in Basic Science Education

    ERIC Educational Resources Information Center

    Helyer, Richard; Dickens, Peter

    2016-01-01

    High-fidelity patient simulators are mainly used to teach clinical skills and remain underutilized in teaching basic sciences. This article summarizes our current views on the use of simulation in basic science education and identifies pitfalls and opportunities for progress.

  20. Comparison of Intervention Fidelity between COPE TEEN and an Attention-Control Program in a Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Kelly, Stephanie A.; Oswalt, Krista; Melnyk, Bernadette Mazurek; Jacobson, Diana

    2015-01-01

    Fidelity in implementing an intervention is critical to accurately determine and interpret the effects of an intervention. It is important to monitor the manner in which the behavioral intervention is implemented (e.g. adaptations, delivery as intended and dose). Few interventions are implemented with 100% fidelity. In this study, high school…

  1. A high-throughput assay for the comprehensive profiling of DNA ligase fidelity

    PubMed Central

    Lohman, Gregory J. S.; Bauer, Robert J.; Nichols, Nicole M.; Mazzola, Laurie; Bybee, Joanna; Rivizzigno, Danielle; Cantin, Elizabeth; Evans, Thomas C.

    2016-01-01

    DNA ligases have broad application in molecular biology, from traditional cloning methods to modern synthetic biology and molecular diagnostics protocols. Ligation-based detection of polynucleotide sequences can be achieved by the ligation of probe oligonucleotides when annealed to a complementary target sequence. In order to achieve a high sensitivity and low background, the ligase must efficiently join correctly base-paired substrates, while discriminating against the ligation of substrates containing even one mismatched base pair. In the current study, we report the use of capillary electrophoresis to rapidly generate mismatch fidelity profiles that interrogate all 256 possible base-pair combinations at a ligation junction in a single experiment. Rapid screening of ligase fidelity in a 96-well plate format has allowed the study of ligase fidelity in unprecedented depth. As an example of this new method, herein we report the ligation fidelity of Thermus thermophilus DNA ligase at a range of temperatures, buffer pH and monovalent cation strength. This screen allows the selection of reaction conditions that maximize fidelity without sacrificing activity, while generating a profile of specific mismatches that ligate detectably under each set of conditions. PMID:26365241

  2. A high-throughput assay for the comprehensive profiling of DNA ligase fidelity.

    PubMed

    Lohman, Gregory J S; Bauer, Robert J; Nichols, Nicole M; Mazzola, Laurie; Bybee, Joanna; Rivizzigno, Danielle; Cantin, Elizabeth; Evans, Thomas C

    2016-01-29

    DNA ligases have broad application in molecular biology, from traditional cloning methods to modern synthetic biology and molecular diagnostics protocols. Ligation-based detection of polynucleotide sequences can be achieved by the ligation of probe oligonucleotides when annealed to a complementary target sequence. In order to achieve a high sensitivity and low background, the ligase must efficiently join correctly base-paired substrates, while discriminating against the ligation of substrates containing even one mismatched base pair. In the current study, we report the use of capillary electrophoresis to rapidly generate mismatch fidelity profiles that interrogate all 256 possible base-pair combinations at a ligation junction in a single experiment. Rapid screening of ligase fidelity in a 96-well plate format has allowed the study of ligase fidelity in unprecedented depth. As an example of this new method, herein we report the ligation fidelity of Thermus thermophilus DNA ligase at a range of temperatures, buffer pH and monovalent cation strength. This screen allows the selection of reaction conditions that maximize fidelity without sacrificing activity, while generating a profile of specific mismatches that ligate detectably under each set of conditions. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. Spawning site fidelity of wild and hatchery lake trout (Salvelinus namaycush) in northern Lake Huron

    USGS Publications Warehouse

    Binder, Thomas; Riley, Stephen C.; Holbrook, Christopher; Hansen, Michael J.; Bergstedt, Roger A.; Bronte, Charles R.; He, Ji; Krueger, Charles C.

    2016-01-01

    Fidelity to high-quality spawning sites helps ensure that adults repeatedly spawn at sites that maximize reproductive success. Fidelity is also an important behavioural characteristic to consider when hatchery-reared individuals are stocked for species restoration, because artificial rearing environments may interfere with cues that guide appropriate spawning site selection. Acoustic telemetry was used in conjunction with Cormack–Jolly–Seber capture–recapture models to compare degree of spawning site fidelity of wild and hatchery-reared lake trout (Salvelinus namaycush) in northern Lake Huron. Annual survival was estimated to be between 77% and 81% and did not differ among wild and hatchery males and females. Site fidelity estimates were high in both wild and hatchery-reared lake trout (ranging from 0.78 to 0.94, depending on group and time filter), but were slightly lower in hatchery-reared fish than in wild fish. The ecological implication of the small difference in site fidelity between wild and hatchery-reared lake trout is unclear, but similarities in estimates suggest that many hatchery-reared fish use similar spawning sites to wild fish and that most return to those sites annually for spawning.

  4. High-fidelity readout in circuit quantum electrodynamics using the Jaynes-Cummings nonlinearity.

    PubMed

    Reed, M D; DiCarlo, L; Johnson, B R; Sun, L; Schuster, D I; Frunzio, L; Schoelkopf, R J

    2010-10-22

    We demonstrate a qubit readout scheme that exploits the Jaynes-Cummings nonlinearity of a superconducting cavity coupled to transmon qubits. We find that, in the strongly driven dispersive regime of this system, there is the unexpected onset of a high-transmission "bright" state at a critical power which depends sensitively on the initial qubit state. A simple and robust measurement protocol exploiting this effect achieves a single-shot fidelity of 87% using a conventional sample design and experimental setup, and at least 61% fidelity to joint correlations of three qubits.

  5. Chip-to-chip entanglement of transmon qubits using engineered measurement fields

    NASA Astrophysics Data System (ADS)

    Dickel, C.; Wesdorp, J. J.; Langford, N. K.; Peiter, S.; Sagastizabal, R.; Bruno, A.; Criger, B.; Motzoi, F.; DiCarlo, L.

    2018-02-01

    While the on-chip processing power in circuit QED devices is growing rapidly, an open challenge is to establish high-fidelity quantum links between qubits on different chips. Here, we show entanglement between transmon qubits on different cQED chips with 49 % concurrence and 73 % Bell-state fidelity. We engineer a half-parity measurement by successively reflecting a coherent microwave field off two nearly identical transmon-resonator systems. By ensuring the measured output field does not distinguish |01 > from |10 > , unentangled superposition states are probabilistically projected onto entangled states in the odd-parity subspace. We use in situ tunability and an additional weakly coupled driving field on the second resonator to overcome imperfect matching due to fabrication variations. To demonstrate the flexibility of this approach, we also produce an even-parity entangled state of similar quality, by engineering the matching of outputs for the |00 > and |11 > states. The protocol is characterized over a range of measurement strengths using quantum state tomography showing good agreement with a comprehensive theoretical model.

  6. Quantitative Technique for Comparing Simulant Materials through Figures of Merit

    NASA Technical Reports Server (NTRS)

    Rickman, Doug; Hoelzer, Hans; Fourroux, Kathy; Owens, Charles; McLemore, Carole; Fikes, John

    2007-01-01

    The 1989 workshop report entitled Workshop on Production and Uses of Simulated Lunar Materials and the Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage, NASA Technical Publication both identified and reinforced a need for a set of standards and requirements for the production and usage of the Lunar simulant materials. As NASA prepares to return to the Moon, and set out to Mars, a set of early requirements have been developed for simulant materials and the initial methods to produce and measure those simulants have been defined. Addressed in the requirements document are: 1) a method for evaluating the quality of any simulant of a regolith, 2) the minimum characteristics for simulants of Lunar regolith, and 3) a method to produce simulants needed for NASA's Exploration mission. As an extension of the requirements document a method to evaluate new and current simulants has been rigorously defined through the mathematics of Figures of Merit (FoM). Requirements and techniques have been developed that allow the simulant provider to compare their product to a standard reference material through Figures of Merit. Standard reference material may be physical material such as the Apollo core samples or material properties predicted for any landing site. The simulant provider is not restricted to providing a single "high fidelity" simulant, which may be costly to produce. The provider can now develop "lower fidelity" simulants for engineering applications such as drilling and mobility applications.

  7. Experimental test of fidelity limits in six-photon interferometry and of rotational invariance properties of the photonic six-qubit entanglement singlet state.

    PubMed

    Rådmark, Magnus; Zukowski, Marek; Bourennane, Mohamed

    2009-10-09

    Quantum multiphoton interferometry has now reached the six-photon stage. Thus far, the observed fidelities of entangled states never reached 2/3. We report a high fidelity (estimated at 88%) experiment in which six-qubit singlet correlations were observed. With such a high fidelity we are able to demonstrate the central property of these "singlet" correlations, their "rotational invariance," by performing a full set of measurements in three complementary polarization bases. The patterns are almost indistinguishable. The data reveal genuine six-photon entanglement. We also study several five-photon states, which result upon detection of one of the photons. Multiphoton singlet states survive some types of depolarization and are thus important in quantum communication schemes.

  8. Multiple displacement amplification in combination with high-fidelity PCR improves detection of bacteria from single females or eggs of Metaseiulus occidentalis (Nesbitt) (Acari: Phytoseiidae).

    PubMed

    Jeyaprakash, Ayyamperumal; Hoy, Marjorie A

    2004-07-01

    Amplifying microbial DNA by the polymerase chain reaction (PCR) from single phytoseiid mites has been difficult, perhaps due to the low titer of bacteria and to interference by the relatively larger amounts of mite genomic DNA. In this paper we evaluate the efficiency of standard and high-fidelity PCR protocols subsequent to amplification of the whole genome by a multiple displacement amplification (MDA) procedure developed by Dean et al. DNA from the phytoseiid Phytoseiulus persimilis (Athias-Henriot) was tested because it lacks a Cytophaga-like organism (CLO) and we could add known amounts of a plasmid containing a cloned 16S rRNA gene fragment from a CLO from Metaseiulus occidentalis (Nesbitt). P. persimilis genomic DNA was mixed with the serially diluted plasmid and amplified using MDA followed by either standard or high-fidelity PCR. MDA followed by high-fidelity PCR was most efficient and successfully amplified an expected 1.5-kb band from as little as 0.01fg of the plasmid, which is equivalent to about 1 copy. MDA followed by high-fidelity PCR also consistently amplified Wolbachia- or CLO-specific products from naturally infected single females or eggs of M. occidentalis, which will allow detailed studies of infection frequency and transmission of several microorganisms associated with this predatory mite.

  9. Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers.

    PubMed

    Schebesta, Karl; Hüpfl, Michael; Rössler, Bernhard; Ringl, Helmut; Müller, Michael P; Kimberger, Oliver

    2012-06-01

    Human patient simulators and airway training manikins are widely used to train airway management skills to medical professionals. Furthermore, these patient simulators are employed as standardized "patients" to evaluate airway devices. However, little is known about how realistic these patient simulators and airway-training manikins really are. This trial aimed to evaluate the upper airway anatomy of four high-fidelity patient simulators and two airway trainers in comparison with actual patients by means of radiographic measurements. The volume of the pharyngeal airspace was the primary outcome parameter. Computed tomography scans of 20 adult trauma patients without head or neck injuries were compared with computed tomography scans of four high-fidelity patient simulators and two airway trainers. By using 14 predefined distances, two cross-sectional areas and three volume parameters of the upper airway, the manikins' similarity to a human patient was assessed. The pharyngeal airspace of all manikins differed significantly from the patients' pharyngeal airspace. The HPS Human Patient Simulator (METI®, Sarasota, FL) was the most realistic high-fidelity patient simulator (6/19 [32%] of all parameters were within the 95% CI of human airway measurements). The airway anatomy of four high-fidelity patient simulators and two airway trainers does not reflect the upper airway anatomy of actual patients. This finding may impact airway training and confound comparative airway device studies.

  10. Automated discrete electron tomography - Towards routine high-fidelity reconstruction of nanomaterials.

    PubMed

    Zhuge, Xiaodong; Jinnai, Hiroshi; Dunin-Borkowski, Rafal E; Migunov, Vadim; Bals, Sara; Cool, Pegie; Bons, Anton-Jan; Batenburg, Kees Joost

    2017-04-01

    Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A weighted variational gradient-based fusion method for high-fidelity thin cloud removal of Landsat images

    NASA Astrophysics Data System (ADS)

    Huang, Wei; Chen, Xiu; Wang, Yueyun

    2018-03-01

    Landsat data are widely used in various earth observations, but the clouds interfere with the applications of the images. This paper proposes a weighted variational gradient-based fusion method (WVGBF) for high-fidelity thin cloud removal of Landsat images, which is an improvement of the variational gradient-based fusion (VGBF) method. The VGBF method integrates the gradient information from the reference band into visible bands of cloudy image to enable spatial details and remove thin clouds. The VGBF method utilizes the same gradient constraints to the entire image, which causes the color distortion in cloudless areas. In our method, a weight coefficient is introduced into the gradient approximation term to ensure the fidelity of image. The distribution of weight coefficient is related to the cloud thickness map. The map is built on Independence Component Analysis (ICA) by using multi-temporal Landsat images. Quantitatively, we use R value to evaluate the fidelity in the cloudless regions and metric Q to evaluate the clarity in the cloud areas. The experimental results indicate that the proposed method has the better ability to remove thin cloud and achieve high fidelity.

  12. Development and validation of the ASPIRE-VA coaching fidelity checklist (ACFC): a tool to help ensure delivery of high-quality weight management interventions.

    PubMed

    Damschroder, Laura J; Goodrich, David E; Kim, Hyungjin Myra; Holleman, Robert; Gillon, Leah; Kirsh, Susan; Richardson, Caroline R; Lutes, Lesley D

    2016-09-01

    Practical and valid instruments are needed to assess fidelity of coaching for weight loss. The purpose of this study was to develop and validate the ASPIRE Coaching Fidelity Checklist (ACFC). Classical test theory guided ACFC development. Principal component analyses were used to determine item groupings. Psychometric properties, internal consistency, and inter-rater reliability were evaluated for each subscale. Criterion validity was tested by predicting weight loss as a function of coaching fidelity. The final 19-item ACFC consists of two domains (session process and session structure) and five subscales (sets goals and monitor progress, assess and personalize self-regulatory content, manages the session, creates a supportive and empathetic climate, and stays on track). Four of five subscales showed high internal consistency (Cronbach alphas > 0.70) for group-based coaching; only two of five subscales had high internal reliability for phone-based coaching. All five sub-scales were positively and significantly associated with weight loss for group- but not for phone-based coaching. The ACFC is a reliable and valid instrument that can be used to assess fidelity and guide skill-building for weight management interventionists.

  13. The use of virtual patient scenarios as a vehicle for teaching professionalism.

    PubMed

    Marei, H F; Al-Eraky, M M; Almasoud, N N; Donkers, J; Van Merrienboer, J J G

    2018-05-01

    This study aimed to measure students' perceptions of virtual patient scenarios (VPs) for developing ethical reasoning skills and to explore features in VP design that are necessary to promote professionalism. Sixty-five dental students participated in learning sessions that involved collaborative practice with five VPs (four high fidelity and one low fidelity), followed by reflection sessions. Students' perceptions towards the use of VPs in developing ethical reasoning skills were assessed using a questionnaire that involved 10 closed and three open-ended questions. High-fidelity VPs were perceived as significantly better for developing ethical reasoning skills than low-fidelity VPs. Analyses of answers to open-ended questions revealed two new features that are specific for VPs intended for teaching professionalism, which are VP dramatic structure and how it should end. VPs intended for teaching professionalism need to have high fidelity, follow a specific dramatic structure and should include multiple plausible endings. The use of VPs as part of a collaborative activity that is followed by a reflection session is perceived as an effective tool for the development of ethical reasoning skills in dental education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. High-Fidelity Multidisciplinary Design Optimization of Aircraft Configurations

    NASA Technical Reports Server (NTRS)

    Martins, Joaquim R. R. A.; Kenway, Gaetan K. W.; Burdette, David; Jonsson, Eirikur; Kennedy, Graeme J.

    2017-01-01

    To evaluate new airframe technologies we need design tools based on high-fidelity models that consider multidisciplinary interactions early in the design process. The overarching goal of this NRA is to develop tools that enable high-fidelity multidisciplinary design optimization of aircraft configurations, and to apply these tools to the design of high aspect ratio flexible wings. We develop a geometry engine that is capable of quickly generating conventional and unconventional aircraft configurations including the internal structure. This geometry engine features adjoint derivative computation for efficient gradient-based optimization. We also added overset capability to a computational fluid dynamics solver, complete with an adjoint implementation and semiautomatic mesh generation. We also developed an approach to constraining buffet and started the development of an approach for constraining utter. On the applications side, we developed a new common high-fidelity model for aeroelastic studies of high aspect ratio wings. We performed optimal design trade-o s between fuel burn and aircraft weight for metal, conventional composite, and carbon nanotube composite wings. We also assessed a continuous morphing trailing edge technology applied to high aspect ratio wings. This research resulted in the publication of 26 manuscripts so far, and the developed methodologies were used in two other NRAs. 1

  15. Competency: Does High Fidelity Simulation Make a Difference?

    ERIC Educational Resources Information Center

    Valente, Alice M.

    2010-01-01

    High fidelity simulation is a well documented adjunctive teaching method in medical and nurse practitioner programs, but few studies of effectiveness on this technology on the development of competency have emphasized pre-licensure associate degree level programs. This study explored student competency in the application of the nursing process…

  16. Using nonfaculty registered nurses to facilitate high-fidelity human patient simulation activities.

    PubMed

    Foster, Janet G; Sheriff, Susan; Cheney, Susan

    2008-01-01

    Maximizing faculty resources using nonfaculty registered nurses to supervise high-fidelity human-patient simulation is an innovative strategy for addressing the nursing faculty shortage and preparing graduates to practice safely in hospitals. The authors describe their use of nonfaculty registered nurses and its outcomes.

  17. Tidal Energy Resource Assessment for McMurdo Station, Antarctica

    DTIC Science & Technology

    2016-12-01

    highest power coefficient possible, only to provide a high- fidelity data set for a simple geometry turbine model at reasonably high blade chord Reynolds...highest power coefficient possible, only to provide a high-fidelity data set for a simple geometry turbine model at reasonably high blade chord...Reynolds numbers. Tip speed ratio, , is defined as = where is the anglular velocity of the blade and is the

  18. Web-Based versus High-Fidelity Simulation Training for Certified Registered Nurse Anesthetists in the Management of High Risk/Low Occurrence Anesthesia Events

    ERIC Educational Resources Information Center

    Kimemia, Judy

    2017-01-01

    Purpose: The purpose of this project was to compare web-based to high-fidelity simulation training in the management of high risk/low occurrence anesthesia related events, to enhance knowledge acquisition for Certified Registered Nurse Anesthetists (CRNAs). This project was designed to answer the question: Is web-based training as effective as…

  19. CTF (Subchannel) Calculations and Validation L3:VVI.H2L.P15.01

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, Natalie

    The goal of the Verification and Validation Implementation (VVI) High to Low (Hi2Lo) process is utilizing a validated model in a high resolution code to generate synthetic data for improvement of the same model in a lower resolution code. This process is useful in circumstances where experimental data does not exist or it is not sufficient in quantity or resolution. Data from the high-fidelity code is treated as calibration data (with appropriate uncertainties and error bounds) which can be used to train parameters that affect solution accuracy in the lower-fidelity code model, thereby reducing uncertainty. This milestone presents a demonstrationmore » of the Hi2Lo process derived in the VVI focus area. The majority of the work performed herein describes the steps of the low-fidelity code used in the process with references to the work detailed in the companion high-fidelity code milestone (Reference 1). The CASL low-fidelity code used to perform this work was Cobra Thermal Fluid (CTF) and the high-fidelity code was STAR-CCM+ (STAR). The master branch version of CTF (pulled May 5, 2017 – Reference 2) was utilized for all CTF analyses performed as part of this milestone. The statistical and VVUQ components of the Hi2Lo framework were performed using Dakota version 6.6 (release date May 15, 2017 – Reference 3). Experimental data from Westinghouse Electric Company (WEC – Reference 4) was used throughout the demonstrated process to compare with the high-fidelity STAR results. A CTF parameter called Beta was chosen as the calibration parameter for this work. By default, Beta is defined as a constant mixing coefficient in CTF and is essentially a tuning parameter for mixing between subchannels. Since CTF does not have turbulence models like STAR, Beta is the parameter that performs the most similar function to the turbulence models in STAR. The purpose of the work performed in this milestone is to tune Beta to an optimal value that brings the CTF results closer to those measured in the WEC experiments.« less

  20. Evaluation of Intervention Fidelity in a Multisite Clinical Trial in Persons With Multiple Sclerosis.

    PubMed

    Morrison, Janet D; Becker, Heather; Stuifbergen, Alexa K

    2017-12-01

    Careful consideration of intervention fidelity is critical to establishing the validity and reliability of research findings, yet such reports are often lacking in the research literature. It is imperative that intervention fidelity be methodically evaluated and reported to promote the translation of effective interventions into sound evidence-based practice. The purpose of this article is to explore strategies used to promote intervention fidelity, incorporating examples from a multisite clinical trial, that illustrate the National Institutes of Health Behavior Change Consortium's 5 domains for recommended treatment practices: (1) study design, (2) facilitator training, (3) intervention delivery, (4) intervention receipt, and (5) intervention enactment. A multisite randomized clinical trial testing the efficacy of a computer-assisted cognitive rehabilitation intervention for adults with multiple sclerosis is used to illustrate strategies promoting intervention fidelity. Data derived from audiotapes of intervention classes, audits of computer exercises completed by participants, participant class attendance, and goal attainment scaling suggested relatively high fidelity to the intervention protocol. This study illustrates how to report intervention fidelity in the literature guided by best practice strategies, which may serve to promote fidelity monitoring and reporting in future studies.

  1. Kriging and local polynomial methods for blending satellite-derived and gauge precipitation estimates to support hydrologic early warning systems

    USGS Publications Warehouse

    Verdin, Andrew; Funk, Christopher C.; Rajagopalan, Balaji; Kleiber, William

    2016-01-01

    Robust estimates of precipitation in space and time are important for efficient natural resource management and for mitigating natural hazards. This is particularly true in regions with developing infrastructure and regions that are frequently exposed to extreme events. Gauge observations of rainfall are sparse but capture the precipitation process with high fidelity. Due to its high resolution and complete spatial coverage, satellite-derived rainfall data are an attractive alternative in data-sparse regions and are often used to support hydrometeorological early warning systems. Satellite-derived precipitation data, however, tend to underrepresent extreme precipitation events. Thus, it is often desirable to blend spatially extensive satellite-derived rainfall estimates with high-fidelity rain gauge observations to obtain more accurate precipitation estimates. In this research, we use two different methods, namely, ordinary kriging and κ-nearest neighbor local polynomials, to blend rain gauge observations with the Climate Hazards Group Infrared Precipitation satellite-derived precipitation estimates in data-sparse Central America and Colombia. The utility of these methods in producing blended precipitation estimates at pentadal (five-day) and monthly time scales is demonstrated. We find that these blending methods significantly improve the satellite-derived estimates and are competitive in their ability to capture extreme precipitation.

  2. DESDynI Quad First Stage Processor - A Four Channel Digitizer and Digital Beam Forming Processor

    NASA Technical Reports Server (NTRS)

    Chuang, Chung-Lun; Shaffer, Scott; Smythe, Robert; Niamsuwan, Noppasin; Li, Samuel; Liao, Eric; Lim, Chester; Morfopolous, Arin; Veilleux, Louise

    2013-01-01

    The proposed Deformation, Eco-Systems, and Dynamics of Ice Radar (DESDynI-R) L-band SAR instrument employs multiple digital channels to optimize resolution while keeping a large swath on a single pass. High-speed digitization with very fine synchronization and digital beam forming are necessary in order to facilitate this new technique. The Quad First Stage Processor (qFSP) was developed to achieve both the processing performance as well as the digitizing fidelity in order to accomplish this sweeping SAR technique. The qFSP utilizes high precision and high-speed analog to digital converters (ADCs), each with a finely adjustable clock distribution network to digitize the channels at the fidelity necessary to allow for digital beam forming. The Xilinx produced FX130T Virtex 5 part handles the processing to digitally calibrate each channel as well as filter and beam form the receive signals. Demonstrating the digital processing required for digital beam forming and digital calibration is instrumental to the viability of the proposed DESDynI instrument. The qFSP development brings this implementation to Technology Readiness Level (TRL) 6. This paper will detail the design and development of the prototype qFSP as well as the preliminary results from hardware tests.

  3. GNOSIS: a novel near-infrared OH suppression unit at the AAT

    NASA Astrophysics Data System (ADS)

    Trinh, C. Q.; Ellis, S. C.; Lawrence, J. S.; Horton, A. J.; Bland-Hawthorn, J.; Leon-Saval, S. G.; Bryant, J.; Case, S.; Colless, M.; Couch, W.; Freeman, K.; Gers, L.; Glazebrook, K.; Haynes, R.; Lee, S.; Löhmannsröben, H.-G.; Miziarski, S.; O'Byrne, J.; Rambold, W.; Roth, M. M.; Schmidt, B.; Shortridge, K.; Smedley, S.; Tinney, C. G.; Xavier, P.; Zheng, J.

    2012-09-01

    GNOSIS has provided the first on-telescope demonstration of a concept to utilize complex aperioidc fiber Bragg gratings to suppress the 103 brightest atmospheric hydroxyl emission doublets between 1.47-1.7 μm. The unit is designed to be used at the 3.9-meter Anglo-Australian Telescope (AAT) feeding the IRIS2 spectrograph. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion. We present the results of laboratory and on-sky tests from instrument commissioning. These tests reveal excellent suppression performance by the gratings and high inter-notch throughput, which combine to produce high fidelity OH-free spectra.

  4. An Efficient Method to Design Premature End-of-Life Trajectories: A Hypothetical Alternate Fate for Cassini

    NASA Technical Reports Server (NTRS)

    Vaquero, Mar; Senent, Juan

    2015-01-01

    What would happen if, hypothetically, the highly successful Cassini mission were to end prematurely due to lack of propellant or sudden subsystem failure? A solid plan to quickly produce a solution for any given scenario, regardless of where the spacecraft is along its reference path, must be in place to safely dispose of the spacecraft and meet all planetary protection requirements. As a contingency plan for this hypothetical situation, a method to design viable high-fidelity terminating trajectories based on a hybrid approach that exploits two-body and three-body flyby transfers combined with a numerical optimization scheme is detailed in this paper.

  5. RNA polymerase II transcriptional fidelity control and its functional interplay with DNA modifications

    PubMed Central

    Xu, Liang; Wang, Wei; Chong, Jenny; Shin, Ji Hyun; Xu, Jun; Wang, Dong

    2016-01-01

    Accurate genetic information transfer is essential for life. As a key enzyme involved in the first step of gene expression, RNA polymerase II (Pol II) must maintain high transcriptional fidelity while it reads along DNA template and synthesizes RNA transcript in a stepwise manner during transcription elongation. DNA lesions or modifications may lead to significant changes in transcriptional fidelity or transcription elongation dynamics. In this review, we will summarize recent progress towards understanding the molecular basis of RNA Pol II transcriptional fidelity control and impacts of DNA lesions and modifications on Pol II transcription elongation. PMID:26392149

  6. [An improved low spectral distortion PCA fusion method].

    PubMed

    Peng, Shi; Zhang, Ai-Wu; Li, Han-Lun; Hu, Shao-Xing; Meng, Xian-Gang; Sun, Wei-Dong

    2013-10-01

    Aiming at the spectral distortion produced in PCA fusion process, the present paper proposes an improved low spectral distortion PCA fusion method. This method uses NCUT (normalized cut) image segmentation algorithm to make a complex hyperspectral remote sensing image into multiple sub-images for increasing the separability of samples, which can weaken the spectral distortions of traditional PCA fusion; Pixels similarity weighting matrix and masks were produced by using graph theory and clustering theory. These masks are used to cut the hyperspectral image and high-resolution image into some sub-region objects. All corresponding sub-region objects between the hyperspectral image and high-resolution image are fused by using PCA method, and all sub-regional integration results are spliced together to produce a new image. In the experiment, Hyperion hyperspectral data and Rapid Eye data were used. And the experiment result shows that the proposed method has the same ability to enhance spatial resolution and greater ability to improve spectral fidelity performance.

  7. Developing an instrument for assessing fidelity of motivational care planning: The Aboriginal and Islander Mental health initiative adherence scale.

    PubMed

    Prowse, Phuong-Tu; Nagel, Tricia

    2014-01-01

    The aim of this study was to design and trial an Adherence Scale to measure fidelity of Motivational Care Planning (MCP) within a clinical trial. This culturally adapted therapy MCP uses a client centered holistic approach that emphasises family and culture to motivate healthy life style changes. The Motivational Care Planning-Adherence Scale (MCP-AS) was developed through consultation with Aboriginal and Islander Mental Health Initiative (AIMhi) Indigenous and non-Indigenous trainers, and review of MCP training resources. The resultant ten-item scale incorporates a 9-Point Likert Scale with a supporting protocol manual and uses objective, behaviourally anchored criteria for each scale point. A fidelity assessor piloted the tool through analysis of four audio-recordings of MCP (conducted by Indigenous researchers within a study in remote communities in Northern Australia). File audits of the remote therapy sessions were utilised as an additional source of information. A Gold Standard Motivational Care Planning training video was also assessed using the MCP-AS. The Motivational Care Planning-Adherence Scale contains items measuring both process and content of therapy sessions. This scale was used successfully to assess therapy through observation of audio or video-recorded sessions and review of clinical notes. Treatment fidelity measured by the MCP-AS within the pilot study indicated high fidelity ratings. Ratings were high across the three domains of rapport, motivation, and self-management with especially high ratings for positive feedback and engagement, review of stressors and goal setting. The Motivational Care Planning-Adherence Scale has the potential to provide a measure of quality of delivery of Motivation Care Planning. The pilot findings suggest that despite challenges within the remote Indigenous community setting, Indigenous therapists delivered therapy that was of high fidelity. While developed as a research tool, the scale has the potential to support fidelity of delivery of Motivation Care Planning in clinical, supervision and training settings. Larger studies are needed to establish inter-rater reliability and internal and external validity.

  8. END-DIASTOLIC FLOW REVERSAL LIMITS THE EFFICACY OF PEDIATRIC INTRAAORTIC BALLOON PUMP COUNTERPULSATION

    PubMed Central

    Bartoli, Carlo R.; Rogers, Benjamin D.; Ionan, Constantine E.; Koenig, Steven C.; Pantalos, George M.

    2013-01-01

    OBJECTIVE Counterpulsation with an intraaortic balloon pump (IABP) has not achieved the same successes or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. METHODS In Yorkshire piglets (n=19, 13.0±0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7cc) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. RESULTS Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105±3bmp, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. CONCLUSIONS Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. PMID:24139614

  9. End-diastolic flow reversal limits the efficacy of pediatric intra-aortic balloon pump counterpulsation.

    PubMed

    Bartoli, Carlo R; Rogers, Benjamin D; Ionan, Constantine E; Pantalos, George M

    2014-05-01

    Counterpulsation with an intra-aortic balloon pump (IABP) has not achieved the same success or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. In Yorkshire piglets (n = 19; weight, 13.0 ± 0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7 mL) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105 ± 3 beats per minute, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. DSMC simulations of the Shuttle Plume Impingement Flight EXperiment(SPIFEX)

    NASA Technical Reports Server (NTRS)

    Stewart, Benedicte; Lumpkin, Forrest

    2017-01-01

    During orbital maneuvers and proximity operations, a spacecraft fires its thrusters inducing plume impingement loads, heating and contamination to itself and to any other nearby spacecraft. These thruster firings are generally modeled using a combination of Computational Fluid Dynamics (CFD) and DSMC simulations. The Shuttle Plume Impingement Flight EXperiment(SPIFEX) produced data that can be compared to a high fidelity simulation. Due to the size of the Shuttle thrusters this problem was too resource intensive to be solved with DSMC when the experiment flew in 1994.

  11. High-Fidelity Rapid Initialization and Read-Out of an Electron Spin via the Single Donor D(-) Charge State.

    PubMed

    Watson, T F; Weber, B; House, M G; Büch, H; Simmons, M Y

    2015-10-16

    We demonstrate high-fidelity electron spin read-out of a precision placed single donor in silicon via spin selective tunneling to either the D(+) or D(-) charge state of the donor. By performing read-out at the stable two electron D(0)↔D(-) charge transition we can increase the tunnel rates to a nearby single electron transistor charge sensor by nearly 2 orders of magnitude, allowing faster qubit read-out (1 ms) with minimum loss in read-out fidelity (98.4%) compared to read-out at the D(+)↔D(0) transition (99.6%). Furthermore, we show that read-out via the D(-) charge state can be used to rapidly initialize the electron spin qubit in its ground state with a fidelity of F(I)=99.8%.

  12. `Inverse Crime' and Model Integrity in Lightcurve Inversion applied to unresolved Space Object Identification

    NASA Astrophysics Data System (ADS)

    Henderson, Laura S.; Subbarao, Kamesh

    2017-12-01

    This work presents a case wherein the selection of models when producing synthetic light curves affects the estimation of the size of unresolved space objects. Through this case, "inverse crime" (using the same model for the generation of synthetic data and data inversion), is illustrated. This is done by using two models to produce the synthetic light curve and later invert it. It is shown here that the choice of model indeed affects the estimation of the shape/size parameters. When a higher fidelity model (henceforth the one that results in the smallest error residuals after the crime is committed) is used to both create, and invert the light curve model the estimates of the shape/size parameters are significantly better than those obtained when a lower fidelity model (in comparison) is implemented for the estimation. It is therefore of utmost importance to consider the choice of models when producing synthetic data, which later will be inverted, as the results might be misleadingly optimistic.

  13. Measures of fidelity of delivery of, and engagement with, complex, face-to-face health behaviour change interventions: A systematic review of measure quality.

    PubMed

    Walton, Holly; Spector, Aimee; Tombor, Ildiko; Michie, Susan

    2017-11-01

    Understanding the effectiveness of complex, face-to-face health behaviour change interventions requires high-quality measures to assess fidelity of delivery and engagement. This systematic review aimed to (1) identify the types of measures used to monitor fidelity of delivery of, and engagement with, complex, face-to-face health behaviour change interventions and (2) describe the reporting of psychometric and implementation qualities. Electronic databases were searched, systematic reviews and reference lists were hand-searched, and 21 experts were contacted to identify articles. Studies that quantitatively measured fidelity of delivery of, and/or engagement with, a complex, face-to-face health behaviour change intervention for adults were included. Data on interventions, measures, and psychometric and implementation qualities were extracted and synthesized using narrative analysis. Sixty-six studies were included: 24 measured both fidelity of delivery and engagement, 20 measured fidelity of delivery, and 22 measured engagement. Measures of fidelity of delivery included observation (n = 17; 38.6%), self-report (n = 15; 34%), quantitatively rated qualitative interviews (n = 1; 2.3%), or multiple measures (n = 11; 25%). Measures of engagement included self-report (n = 18; 39.1%), intervention records (n = 11; 24%), or multiple measures (n = 17; 37%). Fifty-one studies (77%) reported at least one psychometric or implementation quality; 49 studies (74.2%) reported at least one psychometric quality, and 17 studies (25.8%) reported at least one implementation quality. Fewer than half of the reviewed studies measured both fidelity of delivery of, and engagement with complex, face-to-face health behaviour change interventions. More studies reported psychometric qualities than implementation qualities. Interpretation of intervention outcomes from fidelity of delivery and engagement measurements may be limited due to a lack of reporting of psychometric and implementation qualities. Statement of contribution What is already known on this subject? Evidence of fidelity and engagement is needed to understand effectiveness of complex interventions Evidence of fidelity and engagement are rarely reported High-quality measures are needed to measure fidelity and engagement What does this study add? Evidence that indicators of quality of measures are reported in some studies Evidence that psychometric qualities are reported more frequently than implementation qualities A recommendation for intervention evaluations to report indicators of quality of fidelity and engagement measures. © 2017 The Authors. British Journal of Health Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.

  14. Spin qubit transport in a double quantum dot

    NASA Astrophysics Data System (ADS)

    Zhao, Xinyu; Hu, Xuedong

    Long distance spin communication is a crucial ingredient to scalable quantum computer architectures based on electron spin qubits. One way to transfer spin information over a long distance on chip is via electron transport. Here we study the transport of an electron spin qubit in a double quantum dot by tuning the interdot detuning voltage. We identify a parameter regime where spin relaxation hot-spots can be avoided and high-fidelity spin transport is possible. Within this parameter space, the spin transfer fidelity is determined by the operation speed and the applied magnetic field. In particular, near zero detuning, a proper choice of operation speed is essential to high fidelity. In addition, we also investigate the modification of the effective g-factor by the interdot detuning, which could lead to a phase error between spin up and down states. The results presented in this work could be a useful guidance for experimentally achieving high-fidelity spin qubit transport. We thank financial support by US ARO via Grant W911NF1210609.

  15. The Relationship Between Fidelity and Learning in Aviation Training and Assessment

    NASA Technical Reports Server (NTRS)

    Noble, Cliff

    2002-01-01

    Flight simulators can be designed to train pilots or assess their flight performance. Low-Fidelity simulators maximize the initial learning rate of novice pilots and minimize initial costs; whereas, expensive, high-fidelity simulators predict the realworld in-flight performance of expert pilots (Fink & Shriver, 1978 Hays & Singer 1989; Kinkade & Wheaton. 1972). Although intuitively appealing and intellectually convenient to generalize concepts of learning and assessment, what holds true for the role of fidelity in assessment may not always hold true for learning, and vice versa. To bring clarity to this issue, the author distinguishes the role of fidelity in learning from its role in assessment as a function of skill level by applying the hypothesis of Alessi (1988) and reviewing the Laughery, Ditzian, and Houtman (1982) study on simulator validity. Alessi hypothesized that there is it point beyond which one additional unit of flight-simulator fidelity results in a diminished rate of learning. The author of this current paper also suggests the existence of an optimal point beyond which one additional unit of flight-simulator fidelity results in a diminished rate of practical assessment of nonexpert pilot performance.

  16. High fidelity quantum gates with vibrational qubits.

    PubMed

    Berrios, Eduardo; Gruebele, Martin; Shyshlov, Dmytro; Wang, Lei; Babikov, Dmitri

    2012-11-26

    Physical implementation of quantum gates acting on qubits does not achieve a perfect fidelity of 1. The actual output qubit may not match the targeted output of the desired gate. According to theoretical estimates, intrinsic gate fidelities >99.99% are necessary so that error correction codes can be used to achieve perfect fidelity. Here we test what fidelity can be accomplished for a CNOT gate executed by a shaped ultrafast laser pulse interacting with vibrational states of the molecule SCCl(2). This molecule has been used as a test system for low-fidelity calculations before. To make our test more stringent, we include vibrational levels that do not encode the desired qubits but are close enough in energy to interfere with population transfer by the laser pulse. We use two complementary approaches: optimal control theory determines what the best possible pulse can do; a more constrained physical model calculates what an experiment likely can do. Optimal control theory finds pulses with fidelity >0.9999, in excess of the quantum error correction threshold with 8 × 10(4) iterations. On the other hand, the physical model achieves only 0.9992 after 8 × 10(4) iterations. Both calculations converge as an inverse power law toward unit fidelity after >10(2) iterations/generations. In principle, the fidelities necessary for quantum error correction are reachable with qubits encoded by molecular vibrations. In practice, it will be challenging with current laboratory instrumentation because of slow convergence past fidelities of 0.99.

  17. Numerics and subgrid‐scale modeling in large eddy simulations of stratocumulus clouds

    PubMed Central

    Mishra, Siddhartha; Schneider, Tapio; Kaul, Colleen M.; Tan, Zhihong

    2017-01-01

    Abstract Stratocumulus clouds are the most common type of boundary layer cloud; their radiative effects strongly modulate climate. Large eddy simulations (LES) of stratocumulus clouds often struggle to maintain fidelity to observations because of the sharp gradients occurring at the entrainment interfacial layer at the cloud top. The challenge posed to LES by stratocumulus clouds is evident in the wide range of solutions found in the LES intercomparison based on the DYCOMS‐II field campaign, where simulated liquid water paths for identical initial and boundary conditions varied by a factor of nearly 12. Here we revisit the DYCOMS‐II RF01 case and show that the wide range of previous LES results can be realized in a single LES code by varying only the numerical treatment of the equations of motion and the nature of subgrid‐scale (SGS) closures. The simulations that maintain the greatest fidelity to DYCOMS‐II observations are identified. The results show that using weighted essentially non‐oscillatory (WENO) numerics for all resolved advective terms and no explicit SGS closure consistently produces the highest‐fidelity simulations. This suggests that the numerical dissipation inherent in WENO schemes functions as a high‐quality, implicit SGS closure for this stratocumulus case. Conversely, using oscillatory centered difference numerical schemes for momentum advection, WENO numerics for scalars, and explicitly modeled SGS fluxes consistently produces the lowest‐fidelity simulations. We attribute this to the production of anomalously large SGS fluxes near the cloud tops through the interaction of numerical error in the momentum field with the scalar SGS model. PMID:28943997

  18. High Fidelity: Investing in Evaluation Training. Ask the Team

    ERIC Educational Resources Information Center

    Fetters, Jenni

    2013-01-01

    High-quality training is a crucial investment in establishing and maintaining implementation fidelity as well as building educators' trust in the new process. Training approaches for educator evaluation vary both in format (i.e., how it's delivered) and content (i.e., what is provided). Train-the-trainer sessions, online professional learning…

  19. Designing High Fidelity Simulation to Maximize Student Registered Nursing Decision-Making Ability

    ERIC Educational Resources Information Center

    Deckers, Cathleen

    2011-01-01

    The current healthcare environment is a complex system of patients, procedures, and equipment that strives to deliver safe and effective medical care. High fidelity simulation provides healthcare educators with a tool to create safety conscious practitioners utilizing an environment that replicates practice without risk to patients. Using HFS…

  20. 76 FR 60047 - Agency Information Collection Activities; Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-28

    ... Response: Periodic. Total Annual Labor Cost: $18,300 per year ($12,900 for testing + $5,400 for disclosures... and Estimated Burden: (a) Testing--High fidelity manufacturers--300 new products/year x 1 hour each = 300 hours; and (b) Disclosures--High fidelity manufacturers--[(300 new products/ year x 1...

  1. Exploring Interprofessional Education through a High-Fidelity Human Patient Simulation Scenario: A Mixed Methods Study

    ERIC Educational Resources Information Center

    Rossler, Kelly Lynn

    2013-01-01

    High-fidelity human patient simulation has emerged as a valuable medium to reinforce educational content within programs of nursing. As simulation learning experiences have been identified as augmenting both didactic lecture content and clinical learning, these experiences have expanded to incorporate interprofessional education. Review of…

  2. The Impact of Human Patient Simulation on the Attainment of Learning Outcomes

    ERIC Educational Resources Information Center

    Re, Antonio

    2011-01-01

    Human patient simulation, and more specifically, high fidelity patient simulation is a growing teaching technique that enables students in medical and health related professions to learn through interacting with a simulator. This study examined the uses of high fidelity simulation with 106 students enrolled in nursing and respiratory therapist…

  3. The Development of the Simulation Thinking Rubric

    ERIC Educational Resources Information Center

    Doolen, Jessica

    2012-01-01

    High fidelity simulation has become a widespread and costly learning strategy in nursing education because it can fill the gap left by a shortage of clinical sites. In addition, high fidelity simulation is an active learning strategy that is thought to increase higher order thinking such as clinical reasoning and judgment skills in nursing…

  4. Framework for Multidisciplinary Analysis, Design, and Optimization with High-Fidelity Analysis Tools

    NASA Technical Reports Server (NTRS)

    Orr, Stanley A.; Narducci, Robert P.

    2009-01-01

    A plan is presented for the development of a high fidelity multidisciplinary optimization process for rotorcraft. The plan formulates individual disciplinary design problems, identifies practical high-fidelity tools and processes that can be incorporated in an automated optimization environment, and establishes statements of the multidisciplinary design problem including objectives, constraints, design variables, and cross-disciplinary dependencies. Five key disciplinary areas are selected in the development plan. These are rotor aerodynamics, rotor structures and dynamics, fuselage aerodynamics, fuselage structures, and propulsion / drive system. Flying qualities and noise are included as ancillary areas. Consistency across engineering disciplines is maintained with a central geometry engine that supports all multidisciplinary analysis. The multidisciplinary optimization process targets the preliminary design cycle where gross elements of the helicopter have been defined. These might include number of rotors and rotor configuration (tandem, coaxial, etc.). It is at this stage that sufficient configuration information is defined to perform high-fidelity analysis. At the same time there is enough design freedom to influence a design. The rotorcraft multidisciplinary optimization tool is built and substantiated throughout its development cycle in a staged approach by incorporating disciplines sequentially.

  5. High-Fidelity Buckling Analysis of Composite Cylinders Using the STAGS Finite Element Code

    NASA Technical Reports Server (NTRS)

    Hilburger, Mark W.

    2014-01-01

    Results from previous shell buckling studies are presented that illustrate some of the unique and powerful capabilities in the STAGS finite element analysis code that have made it an indispensable tool in structures research at NASA over the past few decades. In particular, prototypical results from the development and validation of high-fidelity buckling simulations are presented for several unstiffened thin-walled compression-loaded graphite-epoxy cylindrical shells along with a discussion on the specific methods and user-defined subroutines in STAGS that are used to carry out the high-fidelity simulations. These simulations accurately account for the effects of geometric shell-wall imperfections, shell-wall thickness variations, local shell-wall ply-gaps associated with the fabrication process, shell-end geometric imperfections, nonuniform applied end loads, and elastic boundary conditions. The analysis procedure uses a combination of nonlinear quasi-static and transient dynamic solution algorithms to predict the prebuckling and unstable collapse response characteristics of the cylinders. Finally, the use of high-fidelity models in the development of analysis-based shell-buckling knockdown (design) factors is demonstrated.

  6. Investigation of Control Inceptor Dynamics and Effect on Human Subject Performance

    NASA Technical Reports Server (NTRS)

    Stanco, Anthony A.; Cardullo, Frank M.; Houck, Jacob A.; Grube, Richard C.; Kelly, Lon C.

    2013-01-01

    The control inceptor used in a vehicle simulation is an important part of adequately representing the dynamics of the vehicle. The inceptor characteristics are typically based on a second order spring mass damper system with damping, force gradient, breakout force, and natural frequency parameters. Changing these parameters can have a great effect on pilot control of the vehicle. A quasi transfer of training experiment was performed employing a high fidelity and a low fidelity control inceptor. A disturbance compensatory task was employed which involved a simple horizon line disturbed in roll by a sum of sinusoids presented in an out-the-window display. Vehicle dynamics were modeled as 1/s and 1/s2. The task was to maintain level flight. Twenty subjects were divided between the high and the low fidelity training groups. Each group was trained to a performance asymptote, and then transferred to the high fidelity simulation. RMS tracking error, a PSD analysis, and a workload analysis were performed to quantify the transfer of training effect. Quantitative results of the experiments show that there is no significant difference between the high and low fidelity training groups for 1/s plant dynamics. For 1/s2 plant dynamics there is a greater difference in tracking performance and PSD; and the subjects are less correlated with the input disturbance function

  7. Implementation and validation of a CubeSat laser transmitter

    NASA Astrophysics Data System (ADS)

    Kingsbury, R. W.; Caplan, D. O.; Cahoy, K. L.

    2016-03-01

    The paper presents implementation and validation results for a CubeSat-scale laser transmitter. The master oscillator power amplifier (MOPA) design produces a 1550 nm, 200mW average power optical signal through the use of a directly modulated laser diode and a commercial fiber amplifier. The prototype design produces high-fidelity M-ary pulse position modulated (PPM) waveforms (M=8 to 128), targeting data rates > 10 Mbit/s while meeting a constraining 8W power allocation. We also present the implementation of an avalanche photodiode (APD) receiver with measured transmitter-to-receiver performance within 3 dB of theory. Via loopback, the compact receiver design can provide built-in self-test and calibration capabilities, and supports incremental on-orbit testing of the design.

  8. Zero-Fidelity Simulation: Engaging Team Coordination without Physical, Functional, or Psychological Re-Creation

    NASA Technical Reports Server (NTRS)

    Toups, Zachary O.; Hamilton, William A.; Kerne, Andruid

    2012-01-01

    Team coordination is essential across domains, enabling efficiency and safety. As technology improves, our temptation is to simulate with ever-higher fidelity, by making simulators re-create reality through their physical interfaces, functionality, and by making participants believe they are undertaking the simulated task. However, high-fidelity simulations often miss salient human-human work practices. We introduce the concept of zero-fidelity simulation (ZFS), a move away from literal high-fidelity mimesis of the concrete environment. ZFS alternatively models cooperation and communication as the basis of simulation. The ZFS Team Coordination Game (TeC) is developed from observation of fire emergency response work practice. We identify ways in which team members are mutually dependent on one another for information, and use these as the basis for the ZFS game design. The design creates a need for cooperation by restricting individual activity and requiring communication. The present research analyzes the design of interdependence in the validated ZFS TeC game. We successfully simulate interdependence between roles in emergency response without simulating the concrete environment.

  9. High-speed and high-fidelity system and method for collecting network traffic

    DOEpatents

    Weigle, Eric H [Los Alamos, NM

    2010-08-24

    A system is provided for the high-speed and high-fidelity collection of network traffic. The system can collect traffic at gigabit-per-second (Gbps) speeds, scale to terabit-per-second (Tbps) speeds, and support additional functions such as real-time network intrusion detection. The present system uses a dedicated operating system for traffic collection to maximize efficiency, scalability, and performance. A scalable infrastructure and apparatus for the present system is provided by splitting the work performed on one host onto multiple hosts. The present system simultaneously addresses the issues of scalability, performance, cost, and adaptability with respect to network monitoring, collection, and other network tasks. In addition to high-speed and high-fidelity network collection, the present system provides a flexible infrastructure to perform virtually any function at high speeds such as real-time network intrusion detection and wide-area network emulation for research purposes.

  10. Optimal Verification of Entangled States with Local Measurements

    NASA Astrophysics Data System (ADS)

    Pallister, Sam; Linden, Noah; Montanaro, Ashley

    2018-04-01

    Consider the task of verifying that a given quantum device, designed to produce a particular entangled state, does indeed produce that state. One natural approach would be to characterize the output state by quantum state tomography, or alternatively, to perform some kind of Bell test, tailored to the state of interest. We show here that neither approach is optimal among local verification strategies for 2-qubit states. We find the optimal strategy in this case and show that quadratically fewer total measurements are needed to verify to within a given fidelity than in published results for quantum state tomography, Bell test, or fidelity estimation protocols. We also give efficient verification protocols for any stabilizer state. Additionally, we show that requiring that the strategy be constructed from local, nonadaptive, and noncollective measurements only incurs a constant-factor penalty over a strategy without these restrictions.

  11. Blending Qualitative and Computational Linguistics Methods for Fidelity Assessment: Experience with the Familias Unidas Preventive Intervention.

    PubMed

    Gallo, Carlos; Pantin, Hilda; Villamar, Juan; Prado, Guillermo; Tapia, Maria; Ogihara, Mitsunori; Cruden, Gracelyn; Brown, C Hendricks

    2015-09-01

    Careful fidelity monitoring and feedback are critical to implementing effective interventions. A wide range of procedures exist to assess fidelity; most are derived from observational assessments (Schoenwald and Garland, Psycholog Assess 25:146-156, 2013). However, these fidelity measures are resource intensive for research teams in efficacy/effectiveness trials, and are often unattainable or unmanageable for the host organization to rate when the program is implemented on a large scale. We present a first step towards automated processing of linguistic patterns in fidelity monitoring of a behavioral intervention using an innovative mixed methods approach to fidelity assessment that uses rule-based, computational linguistics to overcome major resource burdens. Data come from an effectiveness trial of the Familias Unidas intervention, an evidence-based, family-centered preventive intervention found to be efficacious in reducing conduct problems, substance use and HIV sexual risk behaviors among Hispanic youth. This computational approach focuses on "joining," which measures the quality of the working alliance of the facilitator with the family. Quantitative assessments of reliability are provided. Kappa scores between a human rater and a machine rater for the new method for measuring joining reached 0.83. Early findings suggest that this approach can reduce the high cost of fidelity measurement and the time delay between fidelity assessment and feedback to facilitators; it also has the potential for improving the quality of intervention fidelity ratings.

  12. Blending Qualitative and Computational Linguistics Methods for Fidelity Assessment: Experience with the Familias Unidas Preventive Intervention

    PubMed Central

    Gallo, Carlos; Pantin, Hilda; Villamar, Juan; Prado, Guillermo; Tapia, Maria; Ogihara, Mitsunori; Cruden, Gracelyn; Brown, C Hendricks

    2014-01-01

    Careful fidelity monitoring and feedback are critical to implementing effective interventions. A wide range of procedures exist to assess fidelity; most are derived from observational assessments (Schoenwald et al, 2013). However, these fidelity measures are resource intensive for research teams in efficacy/effectiveness trials, and are often unattainable or unmanageable for the host organization to rate when the program is implemented on a large scale. We present a first step towards automated processing of linguistic patterns in fidelity monitoring of a behavioral intervention using an innovative mixed methods approach to fidelity assessment that uses rule-based, computational linguistics to overcome major resource burdens. Data come from an effectiveness trial of the Familias Unidas intervention, an evidence-based, family-centered preventive intervention found to be efficacious in reducing conduct problems, substance use and HIV sexual risk behaviors among Hispanic youth. This computational approach focuses on “joining,” which measures the quality of the working alliance of the facilitator with the family. Quantitative assessments of reliability are provided. Kappa scores between a human rater and a machine rater for the new method for measuring joining reached .83. Early findings suggest that this approach can reduce the high cost of fidelity measurement and the time delay between fidelity assessment and feedback to facilitators; it also has the potential for improving the quality of intervention fidelity ratings. PMID:24500022

  13. Particle infectivity of HIV-1 full-length genome infectious molecular clones in a subtype C heterosexual transmission pair following high fidelity amplification and unbiased cloning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deymier, Martin J., E-mail: mdeymie@emory.edu; Claiborne, Daniel T., E-mail: dclaibo@emory.edu; Ende, Zachary, E-mail: zende@emory.edu

    The high genetic diversity of HIV-1 impedes high throughput, large-scale sequencing and full-length genome cloning by common restriction enzyme based methods. Applying novel methods that employ a high-fidelity polymerase for amplification and an unbiased fusion-based cloning strategy, we have generated several HIV-1 full-length genome infectious molecular clones from an epidemiologically linked transmission pair. These clones represent the transmitted/founder virus and phylogenetically diverse non-transmitted variants from the chronically infected individual's diverse quasispecies near the time of transmission. We demonstrate that, using this approach, PCR-induced mutations in full-length clones derived from their cognate single genome amplicons are rare. Furthermore, all eight non-transmittedmore » genomes tested produced functional virus with a range of infectivities, belying the previous assumption that a majority of circulating viruses in chronic HIV-1 infection are defective. Thus, these methods provide important tools to update protocols in molecular biology that can be universally applied to the study of human viral pathogens. - Highlights: • Our novel methodology demonstrates accurate amplification and cloning of full-length HIV-1 genomes. • A majority of plasma derived HIV variants from a chronically infected individual are infectious. • The transmitted/founder was more infectious than the majority of the variants from the chronically infected donor.« less

  14. Development and Implementation of CFD-Informed Models for the Advanced Subchannel Code CTF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blyth, Taylor S.; Avramova, Maria

    The research described in this PhD thesis contributes to the development of efficient methods for utilization of high-fidelity models and codes to inform low-fidelity models and codes in the area of nuclear reactor core thermal-hydraulics. The objective is to increase the accuracy of predictions of quantities of interests using high-fidelity CFD models while preserving the efficiency of low-fidelity subchannel core calculations. An original methodology named Physics- based Approach for High-to-Low Model Information has been further developed and tested. The overall physical phenomena and corresponding localized effects, which are introduced by the presence of spacer grids in light water reactor (LWR)more » cores, are dissected in corresponding four building basic processes, and corresponding models are informed using high-fidelity CFD codes. These models are a spacer grid-directed cross-flow model, a grid-enhanced turbulent mixing model, a heat transfer enhancement model, and a spacer grid pressure loss model. The localized CFD-models are developed and tested using the CFD code STAR-CCM+, and the corresponding global model development and testing in sub-channel formulation is performed in the thermal- hydraulic subchannel code CTF. The improved CTF simulations utilize data-files derived from CFD STAR-CCM+ simulation results covering the spacer grid design desired for inclusion in the CTF calculation. The current implementation of these models is examined and possibilities for improvement and further development are suggested. The validation experimental database is extended by including the OECD/NRC PSBT benchmark data. The outcome is an enhanced accuracy of CTF predictions while preserving the computational efficiency of a low-fidelity subchannel code.« less

  15. Development and Implementation of CFD-Informed Models for the Advanced Subchannel Code CTF

    NASA Astrophysics Data System (ADS)

    Blyth, Taylor S.

    The research described in this PhD thesis contributes to the development of efficient methods for utilization of high-fidelity models and codes to inform low-fidelity models and codes in the area of nuclear reactor core thermal-hydraulics. The objective is to increase the accuracy of predictions of quantities of interests using high-fidelity CFD models while preserving the efficiency of low-fidelity subchannel core calculations. An original methodology named Physics-based Approach for High-to-Low Model Information has been further developed and tested. The overall physical phenomena and corresponding localized effects, which are introduced by the presence of spacer grids in light water reactor (LWR) cores, are dissected in corresponding four building basic processes, and corresponding models are informed using high-fidelity CFD codes. These models are a spacer grid-directed cross-flow model, a grid-enhanced turbulent mixing model, a heat transfer enhancement model, and a spacer grid pressure loss model. The localized CFD-models are developed and tested using the CFD code STAR-CCM+, and the corresponding global model development and testing in sub-channel formulation is performed in the thermal-hydraulic subchannel code CTF. The improved CTF simulations utilize data-files derived from CFD STAR-CCM+ simulation results covering the spacer grid design desired for inclusion in the CTF calculation. The current implementation of these models is examined and possibilities for improvement and further development are suggested. The validation experimental database is extended by including the OECD/NRC PSBT benchmark data. The outcome is an enhanced accuracy of CTF predictions while preserving the computational efficiency of a low-fidelity subchannel code.

  16. Simulation Learning PC Screen-Based vs. High Fidelity

    DTIC Science & Technology

    2011-08-01

    D., Burgess, L., Berg, B . and Connolly, K . (2009). Teaching mass casualty triage skills using iterative multimanikin simulations. Prehospital...SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON USAMRMC a. REPORT U b . ABSTRACT U...learning PC screen-based vs. high fidelity – progress chart Attachment B . Approved Protocol - Simulation Learning: PC-Screen Based (PCSB) versus High

  17. Fidelity of the representation of value in decision-making

    PubMed Central

    Dowding, Ben A.

    2017-01-01

    The ability to make optimal decisions depends on evaluating the expected rewards associated with different potential actions. This process is critically dependent on the fidelity with which reward value information can be maintained in the nervous system. Here we directly probe the fidelity of value representation following a standard reinforcement learning task. The results demonstrate a previously-unrecognized bias in the representation of value: extreme reward values, both low and high, are stored significantly more accurately and precisely than intermediate rewards. The symmetry between low and high rewards pertained despite substantially higher frequency of exposure to high rewards, resulting from preferential exploitation of more rewarding options. The observed variation in fidelity of value representation retrospectively predicted performance on the reinforcement learning task, demonstrating that the bias in representation has an impact on decision-making. A second experiment in which one or other extreme-valued option was omitted from the learning sequence showed that representational fidelity is primarily determined by the relative position of an encoded value on the scale of rewards experienced during learning. Both variability and guessing decreased with the reduction in the number of options, consistent with allocation of a limited representational resource. These findings have implications for existing models of reward-based learning, which typically assume defectless representation of reward value. PMID:28248958

  18. The Fundamentals of Laparoscopic Surgery and LapVR evaluation metrics may not correlate with operative performance in a novice cohort

    PubMed Central

    Steigerwald, Sarah N.; Park, Jason; Hardy, Krista M.; Gillman, Lawrence; Vergis, Ashley S.

    2015-01-01

    Background Considerable resources have been invested in both low- and high-fidelity simulators in surgical training. The purpose of this study was to investigate if the Fundamentals of Laparoscopic Surgery (FLS, low-fidelity box trainer) and LapVR (high-fidelity virtual reality) training systems correlate with operative performance on the Global Operative Assessment of Laparoscopic Skills (GOALS) global rating scale using a porcine cholecystectomy model in a novice surgical group with minimal laparoscopic experience. Methods Fourteen postgraduate year 1 surgical residents with minimal laparoscopic experience performed tasks from the FLS program and the LapVR simulator as well as a live porcine laparoscopic cholecystectomy. Performance was evaluated using standardized FLS metrics, automatic computer evaluations, and a validated global rating scale. Results Overall, FLS score did not show an association with GOALS global rating scale score on the porcine cholecystectomy. None of the five LapVR task scores were significantly associated with GOALS score on the porcine cholecystectomy. Conclusions Neither the low-fidelity box trainer or the high-fidelity virtual simulator demonstrated significant correlation with GOALS operative scores. These findings offer caution against the use of these modalities for brief assessments of novice surgical trainees, especially for predictive or selection purposes. PMID:26641071

  19. Demonstration of a High-Fidelity Predictive/Preview Display Technique for Telerobotic Servicing in Space

    NASA Technical Reports Server (NTRS)

    Kim, Won S.; Bejczy, Antal K.

    1993-01-01

    A highly effective predictive/preview display technique for telerobotic servicing in space under several seconds communication time delay has been demonstrated on a large laboratory scale in May 1993, involving the Jet Propulsion Laboratory as the simulated ground control station and, 2500 miles away, the Goddard Space Flight Center as the simulated satellite servicing set-up. The technique is based on a high-fidelity calibration procedure that enables a high-fidelity overlay of 3-D graphics robot arm and object models over given 2-D TV camera images of robot arm and objects. To generate robot arm motions, the operator can confidently interact in real time with the graphics models of the robot arm and objects overlaid on an actual camera view of the remote work site. The technique also enables the operator to generate high-fidelity synthetic TV camera views showing motion events that are hidden in a given TV camera view or for which no TV camera views are available. The positioning accuracy achieved by this technique for a zoomed-in camera setting was about +/-5 mm, well within the allowable +/-12 mm error margin at the insertion of a 45 cm long tool in the servicing task.

  20. DDDAMS-based Urban Surveillance and Crowd Control via UAVs and UGVs

    DTIC Science & Technology

    2015-12-04

    for crowd dynamics modeling by incorporating multi-resolution data, where a grid-based method is used to model crowd motion with UAVs’ low -resolution...information and more computational intensive (and time-consuming). Given that the deployment of fidelity selection results in simulation faces computational... low fidelity information FOV y (A) DR x (A) DR y (A) Not detected high fidelity information Table 1: Parameters for UAV and UGV for their detection

  1. Survey of CIG Data Base Generation from Imagery.

    DTIC Science & Technology

    1980-09-01

    world as measured by training transfer. There is no conclusive research as to therequired degree of realism or fidelity necessary to train. In order to...driving force behind emphasizing perceptual fidelity as opposed to realisn is the high cost of realism . Replication of all sensible attri- butes of the...and specification of visual simulation systems will con- tinue to je based on physical fidelity to the real world until those trade-offs on realism

  2. EBT Fidelity Trajectories Across Training Cohorts Using the Interagency Collaborative Team Strategy

    PubMed Central

    Hecht, Debra; Aarons, Greg; Fettes, Danielle; Hurlburt, Michael; Ledesma, Karla

    2015-01-01

    The Interdisciplinary Collaborative Team (ICT) strategy uses front-line providers as adaptation, training and quality control agents for multi-agency EBT implementation. This study tests whether an ICT transmits fidelity to subsequent provider cohorts. SafeCare was implemented by home visitors from multiple community-based agencies contracting with child welfare. Client-reported fidelity trajectories for 5,769 visits, 957 clients and 45 providers were compared using three-level growth models. Provider cohorts trained and live-coached by the ICT attained benchmark fidelity after 12 weeks, and this was sustained. Hispanic clients reported high cultural competency, supporting a cultural adaptation crafted by the ICT. PMID:25586878

  3. EBT Fidelity Trajectories Across Training Cohorts Using the Interagency Collaborative Team Strategy.

    PubMed

    Chaffin, Mark; Hecht, Debra; Aarons, Greg; Fettes, Danielle; Hurlburt, Michael; Ledesma, Karla

    2016-03-01

    The Interdisciplinary Collaborative Team (ICT) strategy uses front-line providers as adaptation, training and quality control agents for multi-agency EBT implementation. This study tests whether an ICT transmits fidelity to subsequent provider cohorts. SafeCare was implemented by home visitors from multiple community-based agencies contracting with child welfare. Client-reported fidelity trajectories for 5,769 visits, 957 clients and 45 providers were compared using three-level growth models. Provider cohorts trained and live-coached by the ICT attained benchmark fidelity after 12 weeks, and this was sustained. Hispanic clients reported high cultural competency, supporting a cultural adaptation crafted by the ICT.

  4. How to Measure Motivational Interviewing Fidelity in Randomized Controlled Trials: Practical Recommendations.

    PubMed

    Jelsma, Judith G M; Mertens, Vera-Christina; Forsberg, Lisa; Forsberg, Lars

    2015-07-01

    Many randomized controlled trials in which motivational interviewing (MI) is a key intervention make no provision for the assessment of treatment fidelity. This methodological shortcoming makes it impossible to distinguish between high- and low-quality MI interventions, and, consequently, to know whether MI provision has contributed to any intervention effects. This article makes some practical recommendations for the collection, selection, coding and reporting of MI fidelity data, as measured using the Motivational Interviewing Treatment Integrity Code. We hope that researchers will consider these recommendations and include MI fidelity measures in future studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Commentary: Learning from Variations in Fidelity of Implementation.

    PubMed

    Balu, Rekha; Doolittle, Fred

    2016-12-01

    The articles in this special issue discuss efforts to improve academic reading outcomes for students and ways to achieve high implementation fidelity of promising strategies. At times the authors discuss if-and how-strong fidelity is associated with strong outcomes and potentially even impacts (the difference between program and control group outcomes). We want to explore this theme in two ways: (a) learning from the variation in fidelity to think about potential points of entry and levers for improvement in implementation, and (b) broadening the evaluation focus to include "service contrast" as a factor driving impacts on student outcomes. We conclude with suggestions for future research. © 2016 Wiley Periodicals, Inc.

  6. A method for assessing fidelity of delivery of telephone behavioral support for smoking cessation.

    PubMed

    Lorencatto, Fabiana; West, Robert; Bruguera, Carla; Michie, Susan

    2014-06-01

    Behavioral support for smoking cessation is delivered through different modalities, often guided by treatment manuals. Recently developed methods for assessing fidelity of delivery have shown that face-to-face behavioral support is often not delivered as specified in the service treatment manual. This study aimed to extend this method to evaluate fidelity of telephone-delivered behavioral support. A treatment manual and transcripts of 75 audio-recorded behavioral support sessions were obtained from the United Kingdom's national Quitline service and coded into component behavior change techniques (BCTs) using a taxonomy of 45 smoking cessation BCTs. Interrater reliability was assessed using percentage agreement. Fidelity was assessed by comparing the number of BCTs identified in the manual with those delivered in telephone sessions by 4 counselors. Fidelity was assessed according to session type, duration, counselor, and BCT. Differences between self-reported and actual BCT use were examined. Average coding reliability was high (81%). On average, 41.8% of manual-specified BCTs were delivered per session (SD = 16.2), with fidelity varying by counselor from 32% to 49%. Fidelity was highest in pre-quit sessions (46%) and for BCT "give options for additional support" (95%). Fidelity was lowest for quit-day sessions (35%) and BCT "set graded tasks" (0%). Session duration was positively correlated with fidelity (r = .585; p < .01). Significantly fewer BCTs were used than were reported as being used, t(15) = -5.52, p < .001. The content of telephone-delivered behavioral support can be reliably coded in terms of BCTs. This can be used to assess fidelity to treatment manuals and to in turn identify training needs. The observed low fidelity underlines the need to establish routine procedures for monitoring delivery of behavioral support. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  7. Early Influences and Later Outcomes Associated With Developmental Trajectories of Eriksonian Fidelity

    PubMed Central

    Brittian, Aerika S.; Lerner, Richard M.

    2014-01-01

    Although Eriksonian theory suggests that adolescents’ sense of fidelity is a key component of healthy development, research on this psychosocial construct has been limited. The current study developed an index of youth fidelity, examined the developmental course of this construct, explored the influence of contextual factors on different fidelity trajectories, and tested if trajectories were associated with later indicators of adolescents’ positive development. Participants included 1,941 ethnically diverse youth (61% female) participants in the 4-H Study of Positive Youth Development who were recruited from schools and youth development programs across the United States. Results suggested that three types of developmental trajectories existed among youth: high and increasing, moderate and increasing, and low and decreasing. Fidelity group membership varied in relation to social relationships and psychosocial and behavioral characteristics (i.e., contribution, substance use, and delinquency). Girls were more likely than boys to be in the highest fidelity trajectories. Directions for future research and implications for enhancing the thriving of adolescents are discussed. PMID:22545838

  8. Construction of nested maximin designs based on successive local enumeration and modified novel global harmony search algorithm

    NASA Astrophysics Data System (ADS)

    Yi, Jin; Li, Xinyu; Xiao, Mi; Xu, Junnan; Zhang, Lin

    2017-01-01

    Engineering design often involves different types of simulation, which results in expensive computational costs. Variable fidelity approximation-based design optimization approaches can realize effective simulation and efficiency optimization of the design space using approximation models with different levels of fidelity and have been widely used in different fields. As the foundations of variable fidelity approximation models, the selection of sample points of variable-fidelity approximation, called nested designs, is essential. In this article a novel nested maximin Latin hypercube design is constructed based on successive local enumeration and a modified novel global harmony search algorithm. In the proposed nested designs, successive local enumeration is employed to select sample points for a low-fidelity model, whereas the modified novel global harmony search algorithm is employed to select sample points for a high-fidelity model. A comparative study with multiple criteria and an engineering application are employed to verify the efficiency of the proposed nested designs approach.

  9. Debriefing after High-Fidelity Simulation and Knowledge Retention: A Quasi-Experimental Study

    ERIC Educational Resources Information Center

    Olson, Susan L.

    2013-01-01

    High-fidelity simulation (HFS) use in nursing education has been a frequent research topic in recent years. Previous research included studies on the use of HFS with nursing students, focusing on their feelings of self-confidence and anxiety. However, research focused specifically on the debriefing portion of HFS was limited. This quantitative,…

  10. Capacity Development and Multi-Tiered Systems of Support: Guiding Principles

    ERIC Educational Resources Information Center

    Sugai, George; Simonsen, Brandi; Freeman, Jennifer; La Salle, Tamika

    2016-01-01

    Implementation of multi-tiered systems of support is occurring within and across a number of countries with an increased recent focus on the development of local system capacity to maintain high levels of practice implementation fidelity. The purpose of this paper is to describe the importance of local capacity development in the high fidelity and…

  11. High-Fidelity Patient Simulators to Expose Undergraduate Students to the Clinical Relevance of Physiology Concepts

    ERIC Educational Resources Information Center

    Harris, David M.; Bellew, Christine; Cheng, Zixi J.; Cendán, Juan C.; Kibble, Jonathan D.

    2014-01-01

    The use of high-fidelity patient simulators (HFPSs) has expanded throughout medical, nursing, and allied health professions education in the last decades. These manikins can be programmed to represent pathological states and are used to teach clinical skills as well as clinical reasoning. First, the students are typically oriented either to the…

  12. The Effect of Learning Styles, Critical Thinking Disposition, and Critical Thinking on Clinical Judgment in Senior Baccalaureate Nursing Students during Human Patient Simulation

    ERIC Educational Resources Information Center

    McCormick, Kiyan

    2014-01-01

    Simulated learning experiences using high-fidelity human patient simulators (HPS) are increasingly being integrated into baccalaureate nursing programs. Thus, the purpose of this study was to examine relationships among learning style, critical thinking disposition, critical thinking, and clinical judgment during high-fidelity human patient…

  13. The Effect of High-Fidelity Cardiopulmonary Resuscitation (CPR) Simulation on Athletic Training Student Knowledge, Confidence, Emotions, and Experiences

    ERIC Educational Resources Information Center

    Tivener, Kristin Ann; Gloe, Donna Sue

    2015-01-01

    Context: High-fidelity simulation is widely used in healthcare for the training and professional education of students though literature of its application to athletic training education remains sparse. Objective: This research attempts to address a wide-range of data. This includes athletic training student knowledge acquisition from…

  14. Evaluating Outcomes of High Fidelity Simulation Curriculum in a Community College Nursing Program

    ERIC Educational Resources Information Center

    Denlea, Gregory Richard

    2017-01-01

    This study took place at a Wake Technical Community College, a multi-campus institution in Raleigh, North Carolina. An evaluation of the return on investment in high fidelity simulation used by an associate degree of nursing program was conducted with valid and reliable instruments. The study demonstrated that comparable student outcomes are…

  15. Physics and Psychophysics of High-Fidelity Sound. Part III: The Components of a Sound-Reproducing System: Amplifiers and Loudspeakers.

    ERIC Educational Resources Information Center

    Rossing, Thomas D.

    1980-01-01

    Described are the components for a high-fidelity sound-reproducing system which focuses on various program sources, the amplifier, and loudspeakers. Discussed in detail are amplifier power and distortion, air suspension, loudspeaker baffles and enclosures, bass-reflex enclosure, drone cones, rear horn and acoustic labyrinth enclosures, horn…

  16. Developing High-Fidelity Health Care Simulation Scenarios: A Guide for Educators and Professionals

    ERIC Educational Resources Information Center

    Alinier, Guillaume

    2011-01-01

    The development of appropriate scenarios is critical in high-fidelity simulation training. They need to be developed to address specific learning objectives, while not preventing other learning points from emerging. Buying a patient simulator, finding a volunteer to act as the patient, or even obtaining ready-made scenarios from another simulation…

  17. Becoming a High-Fidelity--"Super"--Imitator: What Are the Contributions of Social and Individual Learning?

    ERIC Educational Resources Information Center

    Subiaul, Francys; Patterson, Eric M.; Schilder, Brian; Renner, Elizabeth; Barr, Rachel

    2015-01-01

    In contrast to other primates, human children's imitation performance goes from low to high fidelity soon after infancy. Are such changes associated with the development of other forms of learning? We addressed this question by testing 215 children (26-59 months) on two social conditions (imitation, emulation)--involving a demonstration--and two…

  18. Orbit Stability of OSIRIS-REx in the Vicinity of Bennu Using a High-Fidelity Solar Radiation Model

    NASA Technical Reports Server (NTRS)

    Williams, Trevor W.; Hughes, Kyle M.; Mashiku, Alinda K.; Longuski, James M.

    2015-01-01

    Solar radiation pressure is one of the largest perturbing forces on the OSIRISRex trajectory as it orbits the asteroid Bennu. In this work, we investigate how forces due to solar radiation perturb the OSIRIS-REx trajectory in a high-fidelity model. The model accounts for Bennu's non-spherical gravity field, third-body gravity forces from the Sun and Jupiter, as well as solar radiation forces acting on a simplified spacecraft model. Such high-fidelity simulations indicate significant solar radiation pressure perturbations from the nominal orbit. Modifications to the initial design of the nominal orbit are found using a variation of parameters approach that reduce the perturbation in eccentricity by a factor of one-half.

  19. Fast, high-fidelity readout of multiple qubits

    NASA Astrophysics Data System (ADS)

    Bronn, N. T.; Abdo, B.; Inoue, K.; Lekuch, S.; Córcoles, A. D.; Hertzberg, J. B.; Takita, M.; Bishop, L. S.; Gambetta, J. M.; Chow, J. M.

    2017-05-01

    Quantum computing requires a delicate balance between coupling quantum systems to external instruments for control and readout, while providing enough isolation from sources of decoherence. Circuit quantum electrodynamics has been a successful method for protecting superconducting qubits, while maintaining the ability to perform readout [1, 2]. Here, we discuss improvements to this method that allow for fast, high-fidelity readout. Specifically, the integration of a Purcell filter, which allows us to increase the resonator bandwidth for fast readout, the incorporation of a Josephson parametric converter, which enables us to perform high-fidelity readout by amplifying the readout signal while adding the minimum amount of noise required by quantum mechanics, and custom control electronics, which provide us with the capability of fast decision and control.

  20. High-fidelity cluster state generation for ultracold atoms in an optical lattice.

    PubMed

    Inaba, Kensuke; Tokunaga, Yuuki; Tamaki, Kiyoshi; Igeta, Kazuhiro; Yamashita, Makoto

    2014-03-21

    We propose a method for generating high-fidelity multipartite spin entanglement of ultracold atoms in an optical lattice in a short operation time with a scalable manner, which is suitable for measurement-based quantum computation. To perform the desired operations based on the perturbative spin-spin interactions, we propose to actively utilize the extra degrees of freedom (DOFs) usually neglected in the perturbative treatment but included in the Hubbard Hamiltonian of atoms, such as, (pseudo-)charge and orbital DOFs. Our method simultaneously achieves high fidelity, short operation time, and scalability by overcoming the following fundamental problem: enhancing the interaction strength for shortening the operation time breaks the perturbative condition of the interaction and inevitably induces unwanted correlations among the spin and extra DOFs.

  1. Long lifetime and high-fidelity quantum memory of photonic polarization qubit by lifting zeeman degeneracy.

    PubMed

    Xu, Zhongxiao; Wu, Yuelong; Tian, Long; Chen, Lirong; Zhang, Zhiying; Yan, Zhihui; Li, Shujing; Wang, Hai; Xie, Changde; Peng, Kunchi

    2013-12-13

    Long-lived and high-fidelity memory for a photonic polarization qubit (PPQ) is crucial for constructing quantum networks. We present a millisecond storage system based on electromagnetically induced transparency, in which a moderate magnetic field is applied on a cold-atom cloud to lift Zeeman degeneracy and, thus, the PPQ states are stored as two magnetic-field-insensitive spin waves. Especially, the influence of magnetic-field-sensitive spin waves on the storage performances is almost totally avoided. The measured average fidelities of the polarization states are 98.6% at 200  μs and 78.4% at 4.5 ms, respectively.

  2. Instrument modifications that produced reduced plate heights <2 with sub-2 μm particles and 95% of theoretical efficiency at k=2 in supercritical fluid chromatography.

    PubMed

    Berger, Terry A

    2016-04-29

    The concept of peak fidelity was shown to be helpful in modeling tubing and detector cell dimensions. Connection tubing and flow cell variances were modeled to determine appropriate internal ID's, lengths, and volumes. A low dispersion plumbing configuration, based on these calculations, was assembled to replace the standard plumbing and produced the reported results. The modifications made were straightforward using commercially available parts. The full theoretical efficiency of a 3×100 mm column packed with 1.8 μm totally porous particles was achieved for the first time in supercritical fluid chromatography (SFC). Peak fidelity of >0.95 was maintained to below k=2. A reduced plate height as low as 1.87 was measured. Thus, true "ultra high performance" SFC was achieved, with the results a major improvement from all previous SFC reports. Since there were no efficiency losses, none could be attributed to thermal gradients caused by the expansion of the fluid over large pressure drops, under the conditions used. Similarly, changes in diffusion coefficients caused by significant decreases in density during expansion are apparently balanced by the increase in linear velocity, keeping the ratio between the diffusion coefficient and the linear velocity a constant. Changing modifier concentration to change retention was shown to not be a significant problem. All these issues have been a concern in the past. Diffusion coefficients, and viscosity data needs to be collected at high pressures before the actual limits of SFC can be discovered. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Investigating variations in implementation fidelity of an organizational-level occupational health intervention.

    PubMed

    Augustsson, Hanna; von Thiele Schwarz, Ulrica; Stenfors-Hayes, Terese; Hasson, Henna

    2015-06-01

    The workplace has been suggested as an important arena for health promotion, but little is known about how the organizational setting influences the implementation of interventions. The aims of this study are to evaluate implementation fidelity in an organizational-level occupational health intervention and to investigate possible explanations for variations in fidelity between intervention units. The intervention consisted of an integration of health promotion, occupational health and safety, and a system for continuous improvements (Kaizen) and was conducted in a quasi-experimental design at a Swedish hospital. Implementation fidelity was evaluated with the Conceptual Framework for Implementation Fidelity and implementation factors used to investigate variations in fidelity with the Framework for Evaluating Organizational-level Interventions. A multi-method approach including interviews, Kaizen notes, and questionnaires was applied. Implementation fidelity differed between units even though the intervention was introduced and supported in the same way. Important differences in all elements proposed in the model for evaluating organizational-level interventions, i.e., context, intervention, and mental models, were found to explain the differences in fidelity. Implementation strategies may need to be adapted depending on the local context. Implementation fidelity, as well as pre-intervention implementation elements, is likely to affect the implementation success and needs to be assessed in intervention research. The high variation in fidelity across the units indicates the need for adjustments to the type of designs used to assess the effects of interventions. Thus, rather than using designs that aim to control variation, it may be necessary to use those that aim at exploring and explaining variation, such as adapted study designs.

  4. Site fidelity, territory fidelity, and natal philopatry in Willow Flycatchers (Empidonax traillii)

    USGS Publications Warehouse

    Sedgwick, James A.

    2004-01-01

    I investigated the causes and consequences of adult breeding-site fidelity, territory fidelity, and natal philopatry in Willow Flycatchers (Empidonax traillii) in southeastern Oregon over a 10-year period, testing the general hypothesis that fidelity and dispersal distances are influenced by previous breeding performance. Willow Flycatchers adhered to the generally observed tendencies of passerine birds for low natal philopatry and high breedingsite fidelity. Site fidelity (return to the study area) of adult males (52.0%) and females (51.3%), and median dispersal distances between seasons (16 m vs. 19 m) were similar. Previous breeding performance and residency (age-experience), but not study-site quality, explained site fidelity in females. Site fidelity of females rearing 4–5 young (64.4%) exceeded that of unsuccessful females (40.0%), breeding dispersal was less (successful: 15 m; unsuccessful: 33 m), and novice residents were more site-faithful than former residents. Probability of site fidelity was higher for previously successful females (odds ratio = 4.76), those with greater seasonal fecundity (odds ratio = 1.58), novice residents (odds ratio = 1.41), and unparasitized females (odds ratio = 2.76). Male site fidelity was not related to residency, site quality, or previous breeding performance. Territory fidelity (return to the previous territory) in females was best explained by previous breeding performance, but not by site quality or residency. Previously successful females were more likely to return to their territory of the previous season than either unsuccessful (odds ratio = 14.35) or parasitized birds (odds ratio = 6.38). Male territory fidelity was not related to residency, site quality, or previous breeding performance. Natal philopatry was low (7.8%) and similar for males and females. Site quality appeared to influence philopatry, given that no birds reared at a low-quality study site returned there to breed, and birds reared there dispersed farther than birds reared at two other study sites. My results partially support the hypothesis that site fidelity is an adaptive response: (1) previously successful females that switched territories underperformed those that did not switch (P = 0.01); and (2) previously unsuccessful females that switched territories outperformed those that did not switch, but not significantly (P = 0.22).

  5. Developing effective serious games: the effect of background sound on visual fidelity perception with varying texture resolution.

    PubMed

    Rojas, David; Kapralos, Bill; Cristancho, Sayra; Collins, Karen; Hogue, Andrew; Conati, Cristina; Dubrowski, Adam

    2012-01-01

    Despite the benefits associated with virtual learning environments and serious games, there are open, fundamental issues regarding simulation fidelity and multi-modal cue interaction and their effect on immersion, transfer of knowledge, and retention. Here we describe the results of a study that examined the effect of ambient (background) sound on the perception of visual fidelity (defined with respect to texture resolution). Results suggest that the perception of visual fidelity is dependent on ambient sound and more specifically, white noise can have detrimental effects on our perception of high quality visuals. The results of this study will guide future studies that will ultimately aid in developing an understanding of the role that fidelity, and multi-modal interactions play with respect to knowledge transfer and retention for users of virtual simulations and serious games.

  6. Multifamily Group Psychoeducation in New York State: Implementation and Fidelity Outcomes.

    PubMed

    Kealey, Edith M; Leckman-Westin, Emily; Jewell, Thomas C; Finnerty, Molly T

    2015-11-01

    The study examined implementation outcomes from a large state initiative to support dissemination of multifamily group (MFG) psychoeducation in outpatient mental health settings. Thirty-one sites participated in the project. Baseline training in the MFG model was followed by monthly expert consultation delivered in either a group (16 sites) or individual format (15 sites). Research staff assessed fidelity to the MFG model by telephone at baseline and 12, 18, and 24 months and documented time to completion of three key milestones: holding a family joining session, a family educational workshop, and an MFG meeting. Intent-to-train analyses found that 12 sites (39%) achieved high fidelity to the MFG model, and 20 (65%) achieved moderate or high fidelity. Mean scores on the Family Psychoeducation Fidelity Assessment Scale increased over time. Twenty-five sites (81%) conducted at least one joining session, and 20 (65%) conducted at least one MFG. Mean±SD time from baseline to the first group was 11.75±4.78 months. Programs that held the first joining session within four to 12 months after training were significantly more likely than programs that did not to conduct a group (p<.05). No significant differences were found by consultation format. Implementation of moderate- to high-fidelity MFG programs in routine outpatient mental health settings is feasible. Sites that moved very quickly or very slowly in early implementation stages were less likely to be successful in conducting an MFG. More research on the efficiency and effectiveness of consultation formats is needed to guide future implementation efforts.

  7. Use of VR Technology and Passive Haptics for MANPADS Training System

    DTIC Science & Technology

    2017-09-01

    this setup also does not offer a variety of challenging scenarios needed for good training as the aircraft are mostly flying in landing or take-off... customized high-fidelity immersive training facilities are limited. Moreover, low trainee throughput from such high-end facilities is an ongoing obstacle...opportunities allow few operators to fire during live exercises. Simulation training is effective, but customized high-fidelity immersive training

  8. Regularized Dual Averaging Image Reconstruction for Full-Wave Ultrasound Computed Tomography.

    PubMed

    Matthews, Thomas P; Wang, Kun; Li, Cuiping; Duric, Neb; Anastasio, Mark A

    2017-05-01

    Ultrasound computed tomography (USCT) holds great promise for breast cancer screening. Waveform inversion-based image reconstruction methods account for higher order diffraction effects and can produce high-resolution USCT images, but are computationally demanding. Recently, a source encoding technique has been combined with stochastic gradient descent (SGD) to greatly reduce image reconstruction times. However, this method bundles the stochastic data fidelity term with the deterministic regularization term. This limitation can be overcome by replacing SGD with a structured optimization method, such as the regularized dual averaging method, that exploits knowledge of the composition of the cost function. In this paper, the dual averaging method is combined with source encoding techniques to improve the effectiveness of regularization while maintaining the reduced reconstruction times afforded by source encoding. It is demonstrated that each iteration can be decomposed into a gradient descent step based on the data fidelity term and a proximal update step corresponding to the regularization term. Furthermore, the regularization term is never explicitly differentiated, allowing nonsmooth regularization penalties to be naturally incorporated. The wave equation is solved by the use of a time-domain method. The effectiveness of this approach is demonstrated through computer simulation and experimental studies. The results suggest that the dual averaging method can produce images with less noise and comparable resolution to those obtained by the use of SGD.

  9. Development of Adaptive Model Refinement (AMoR) for Multiphysics and Multifidelity Problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turinsky, Paul

    This project investigated the development and utilization of Adaptive Model Refinement (AMoR) for nuclear systems simulation applications. AMoR refers to utilization of several models of physical phenomena which differ in prediction fidelity. If the highest fidelity model is judged to always provide or exceeded the desired fidelity, than if one can determine the difference in a Quantity of Interest (QoI) between the highest fidelity model and lower fidelity models, one could utilize the fidelity model that would just provide the magnitude of the QoI desired. Assuming lower fidelity models require less computational resources, in this manner computational efficiency can bemore » realized provided the QoI value can be accurately and efficiently evaluated. This work utilized Generalized Perturbation Theory (GPT) to evaluate the QoI, by convoluting the GPT solution with the residual of the highest fidelity model determined using the solution from lower fidelity models. Specifically, a reactor core neutronics problem and thermal-hydraulics problem were studied to develop and utilize AMoR. The highest fidelity neutronics model was based upon the 3D space-time, two-group, nodal diffusion equations as solved in the NESTLE computer code. Added to the NESTLE code was the ability to determine the time-dependent GPT neutron flux. The lower fidelity neutronics model was based upon the point kinetics equations along with utilization of a prolongation operator to determine the 3D space-time, two-group flux. The highest fidelity thermal-hydraulics model was based upon the space-time equations governing fluid flow in a closed channel around a heat generating fuel rod. The Homogenous Equilibrium Mixture (HEM) model was used for the fluid and Finite Difference Method was applied to both the coolant and fuel pin energy conservation equations. The lower fidelity thermal-hydraulic model was based upon the same equations as used for the highest fidelity model but now with coarse spatial meshing, corrected somewhat by employing effective fuel heat conduction values. The effectiveness of switching between the highest fidelity model and lower fidelity model as a function of time was assessed using the neutronics problem. Based upon work completed to date, one concludes that the time switching is effective in annealing out differences between the highest and lower fidelity solutions. The effectiveness of using a lower fidelity GPT solution, along with a prolongation operator, to estimate the QoI was also assessed. The utilization of a lower fidelity GPT solution was done in an attempt to avoid the high computational burden associated with solving for the highest fidelity GPT solution. Based upon work completed to date, one concludes that the lower fidelity adjoint solution is not sufficiently accurate with regard to estimating the QoI; however, a formulation has been revealed that may provide a path for addressing this shortcoming.« less

  10. Long Live Love+: evaluation of the implementation of an online school-based sexuality education program in the Netherlands.

    PubMed

    van Lieshout, Sanne; Mevissen, Fraukje; de Waal, Esri; Kok, Gerjo

    2017-06-01

    Schools are a common setting for adolescents to receive health education, but implementation of these programs with high levels of completeness and fidelity is not self-evident. Programs that are only partially implemented (completeness) or not implemented as instructed (fidelity) are unlikely to be effective. Therefore, it is important to identify which determinants affect completeness and fidelity of program implementation. As part of the launch of Long Live Love+ (LLL+), an online school-based sexuality education program for adolescents aged 15-17, we performed a process evaluation among teachers and students to measure the levels of completeness and fidelity, identify factors influencing teachers' implementation, and to evaluate the students' response. Sixteen Biology teachers from nine secondary schools throughout the Netherlands who implemented LLL+ were interviewed and 60 students participated in 13 focus group discussions. Results showed that teachers' completeness ranged between 22-100% (M = 75%). Fidelity was high, but many teachers added elements. Teachers and students enjoyed LLL+, particularly the diversity in the exercises and its interactive character. The most important factors that influenced implementation were time and organizational constraints, lack of awareness on the impact of completeness and fidelity, and student response. These factors should be taken into account when developing school-based prevention programs. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. Fidelity assessment of a UH-60A simulation on the NASA Ames vertical motion simulator

    NASA Technical Reports Server (NTRS)

    Atencio, Adolph, Jr.

    1993-01-01

    Helicopter handling qualities research requires that a ground-based simulation be a high-fidelity representation of the actual helicopter, especially over the frequency range of the investigation. This experiment was performed to assess the current capability to simulate the UH-60A Black Hawk helicopter on the Vertical Motion Simulator (VMS) at NASA Ames, to develop a methodology for assessing the fidelity of a simulation, and to find the causes for lack of fidelity. The approach used was to compare the simulation to the flight vehicle for a series of tasks performed in flight and in the simulator. The results show that subjective handling qualities ratings from flight to simulator overlap, and the mathematical model matches the UH-60A helicopter very well over the range of frequencies critical to handling qualities evaluation. Pilot comments, however, indicate a need for improvement in the perceptual fidelity of the simulation in the areas of motion and visual cuing. The methodology used to make the fidelity assessment proved useful in showing differences in pilot work load and strategy, but additional work is needed to refine objective methods for determining causes of lack of fidelity.

  12. Unbiased multi-fidelity estimate of failure probability of a free plane jet

    NASA Astrophysics Data System (ADS)

    Marques, Alexandre; Kramer, Boris; Willcox, Karen; Peherstorfer, Benjamin

    2017-11-01

    Estimating failure probability related to fluid flows is a challenge because it requires a large number of evaluations of expensive models. We address this challenge by leveraging multiple low fidelity models of the flow dynamics to create an optimal unbiased estimator. In particular, we investigate the effects of uncertain inlet conditions in the width of a free plane jet. We classify a condition as failure when the corresponding jet width is below a small threshold, such that failure is a rare event (failure probability is smaller than 0.001). We estimate failure probability by combining the frameworks of multi-fidelity importance sampling and optimal fusion of estimators. Multi-fidelity importance sampling uses a low fidelity model to explore the parameter space and create a biasing distribution. An unbiased estimate is then computed with a relatively small number of evaluations of the high fidelity model. In the presence of multiple low fidelity models, this framework offers multiple competing estimators. Optimal fusion combines all competing estimators into a single estimator with minimal variance. We show that this combined framework can significantly reduce the cost of estimating failure probabilities, and thus can have a large impact in fluid flow applications. This work was funded by DARPA.

  13. Optical nano-woodpiles: large-area metallic photonic crystals and metamaterials.

    PubMed

    Ibbotson, Lindsey A; Demetriadou, Angela; Croxall, Stephen; Hess, Ortwin; Baumberg, Jeremy J

    2015-02-09

    Metallic woodpile photonic crystals and metamaterials operating across the visible spectrum are extremely difficult to construct over large areas, because of the intricate three-dimensional nanostructures and sub-50 nm features demanded. Previous routes use electron-beam lithography or direct laser writing but widespread application is restricted by their expense and low throughput. Scalable approaches including soft lithography, colloidal self-assembly, and interference holography, produce structures limited in feature size, material durability, or geometry. By multiply stacking gold nanowire flexible gratings, we demonstrate a scalable high-fidelity approach for fabricating flexible metallic woodpile photonic crystals, with features down to 10 nm produced in bulk and at low cost. Control of stacking sequence, asymmetry, and orientation elicits great control, with visible-wavelength band-gap reflections exceeding 60%, and with strong induced chirality. Such flexible and stretchable architectures can produce metamaterials with refractive index near zero, and are easily tuned across the IR and visible ranges.

  14. High Fidelity Measurement and Modeling of Interactions between Acoustics and Heat Release in Highly-Compact, High-Pressure Flames

    DTIC Science & Technology

    2016-05-24

    experimental data. However, the time and length scales, and energy deposition rates in the canonical laboratory flames that have been studied over the...is to obtain high-fidelity experimental data critically needed to validate research codes at relevant conditions, and to develop systematic and...validated with experimental data. However, the time and length scales, and energy deposition rates in the canonical laboratory flames that have been

  15. Fluid/Structure Interaction Studies of Aircraft Using High Fidelity Equations on Parallel Computers

    NASA Technical Reports Server (NTRS)

    Guruswamy, Guru; VanDalsem, William (Technical Monitor)

    1994-01-01

    Abstract Aeroelasticity which involves strong coupling of fluids, structures and controls is an important element in designing an aircraft. Computational aeroelasticity using low fidelity methods such as the linear aerodynamic flow equations coupled with the modal structural equations are well advanced. Though these low fidelity approaches are computationally less intensive, they are not adequate for the analysis of modern aircraft such as High Speed Civil Transport (HSCT) and Advanced Subsonic Transport (AST) which can experience complex flow/structure interactions. HSCT can experience vortex induced aeroelastic oscillations whereas AST can experience transonic buffet associated structural oscillations. Both aircraft may experience a dip in the flutter speed at the transonic regime. For accurate aeroelastic computations at these complex fluid/structure interaction situations, high fidelity equations such as the Navier-Stokes for fluids and the finite-elements for structures are needed. Computations using these high fidelity equations require large computational resources both in memory and speed. Current conventional super computers have reached their limitations both in memory and speed. As a result, parallel computers have evolved to overcome the limitations of conventional computers. This paper will address the transition that is taking place in computational aeroelasticity from conventional computers to parallel computers. The paper will address special techniques needed to take advantage of the architecture of new parallel computers. Results will be illustrated from computations made on iPSC/860 and IBM SP2 computer by using ENSAERO code that directly couples the Euler/Navier-Stokes flow equations with high resolution finite-element structural equations.

  16. The Effects of Moderate- and High-Fidelity Patient Simulator Use on Critical Thinking in Associate Degree Nursing Students

    ERIC Educational Resources Information Center

    Vieck, Jana

    2013-01-01

    The purpose of this study was to examine the impact of moderate- and high-fidelity patient simulator use on the critical thinking skills of associate degree nursing students. This quantitative study used a quasi-experimental design and the Health Sciences Reasoning Test (HSRT) to evaluate the critical thinking skills of third semester nursing…

  17. Using a High-Fidelity Patient Simulator with First-Year Medical Students to Facilitate Learning of Cardiovascular Function Curves

    ERIC Educational Resources Information Center

    Harris, David M.; Ryan, Kathleen; Rabuck, Cynthia

    2012-01-01

    Students are relying on technology for learning more than ever, and educators need to adapt to facilitate student learning. High-fidelity patient simulators (HFPS) are usually reserved for the clinical years of medical education and are geared to improve clinical decision skills, teamwork, and patient safety. Finding ways to incorporate HFPS into…

  18. Modeling of Passive Acoustic Liners from High Fidelity Numerical Simulations

    NASA Astrophysics Data System (ADS)

    Ferrari, Marcello do Areal Souto

    Noise reduction in aviation has been an important focus of study in the last few decades. One common solution is setting up acoustic liners in the internal walls of the engines. However, measurements in the laboratory with liners are expensive and time consuming. The present work proposes a nonlinear physics-based time domain model to predict the acoustic behavior of a given liner in a defined flow condition. The parameters of the model are defined by analysis of accurate numerical solutions of the flow obtained from a high-fidelity numerical code. The length of the cavity is taken into account by using an analytical procedure to account for internal reflections in the interior of the cavity. Vortices and jets originated from internal flow separations are confirmed to be important mechanisms of sound absorption, which defines the overall efficiency of the liner. Numerical simulations at different frequency, geometry and sound pressure level are studied in detail to define the model parameters. Comparisons with high-fidelity numerical simulations show that the proposed model is accurate, robust, and can be used to define a boundary condition simulating a liner in a high-fidelity code.

  19. Biocompatible artificial DNA linker that is read through by DNA polymerases and is functional in Escherichia coli

    PubMed Central

    El-Sagheer, Afaf H.; Sanzone, A. Pia; Gao, Rachel; Tavassoli, Ali; Brown, Tom

    2011-01-01

    A triazole mimic of a DNA phosphodiester linkage has been produced by templated chemical ligation of oligonucleotides functionalized with 5′-azide and 3′-alkyne. The individual azide and alkyne oligonucleotides were synthesized by standard phosphoramidite methods and assembled using a straightforward ligation procedure. This highly efficient chemical equivalent of enzymatic DNA ligation has been used to assemble a 300-mer from three 100-mer oligonucleotides, demonstrating the total chemical synthesis of very long oligonucleotides. The base sequences of the DNA strands containing this artificial linkage were copied during PCR with high fidelity and a gene containing the triazole linker was functional in Escherichia coli. PMID:21709264

  20. Comparison of Low-Thrust Control Laws for Application in Planetocentric Space

    NASA Technical Reports Server (NTRS)

    Falck, Robert D.; Sjauw, Waldy K.; Smith, David A.

    2014-01-01

    Recent interest at NASA for the application of solar electric propulsion for the transfer of significant payloads in cislunar space has led to the development of high-fidelity simulations of such missions. With such transfers involving transfer times on the order of months, simulation time can be significant. In the past, the examination of such missions typically began with the use of lower-fidelity trajectory optimization tools such as SEPSPOT to develop and tune guidance laws which delivered optimal or near- optimal trajectories, where optimal is generally defined as minimizing propellant expenditure or time of flight. The transfer of these solutions to a high-fidelity simulation is typically an iterative process whereby the initial solution may nearly, but not precisely, meet mission objectives. Further tuning of the guidance algorithm is typically necessary when accounting for high-fidelity perturbations such as those due to more detailed gravity models, secondary-body effects, solar radiation pressure, etc. While trajectory optimization is a useful method for determining optimal performance metrics, algorithms which deliver nearly optimal performance with minimal tuning are an attractive alternative.

  1. An adaptive sampling method for variable-fidelity surrogate models using improved hierarchical kriging

    NASA Astrophysics Data System (ADS)

    Hu, Jiexiang; Zhou, Qi; Jiang, Ping; Shao, Xinyu; Xie, Tingli

    2018-01-01

    Variable-fidelity (VF) modelling methods have been widely used in complex engineering system design to mitigate the computational burden. Building a VF model generally includes two parts: design of experiments and metamodel construction. In this article, an adaptive sampling method based on improved hierarchical kriging (ASM-IHK) is proposed to refine the improved VF model. First, an improved hierarchical kriging model is developed as the metamodel, in which the low-fidelity model is varied through a polynomial response surface function to capture the characteristics of a high-fidelity model. Secondly, to reduce local approximation errors, an active learning strategy based on a sequential sampling method is introduced to make full use of the already required information on the current sampling points and to guide the sampling process of the high-fidelity model. Finally, two numerical examples and the modelling of the aerodynamic coefficient for an aircraft are provided to demonstrate the approximation capability of the proposed approach, as well as three other metamodelling methods and two sequential sampling methods. The results show that ASM-IHK provides a more accurate metamodel at the same simulation cost, which is very important in metamodel-based engineering design problems.

  2. Neurobionics and the brain-computer interface: current applications and future horizons.

    PubMed

    Rosenfeld, Jeffrey V; Wong, Yan Tat

    2017-05-01

    The brain-computer interface (BCI) is an exciting advance in neuroscience and engineering. In a motor BCI, electrical recordings from the motor cortex of paralysed humans are decoded by a computer and used to drive robotic arms or to restore movement in a paralysed hand by stimulating the muscles in the forearm. Simultaneously integrating a BCI with the sensory cortex will further enhance dexterity and fine control. BCIs are also being developed to: provide ambulation for paraplegic patients through controlling robotic exoskeletons; restore vision in people with acquired blindness; detect and control epileptic seizures; and improve control of movement disorders and memory enhancement. High-fidelity connectivity with small groups of neurons requires microelectrode placement in the cerebral cortex. Electrodes placed on the cortical surface are less invasive but produce inferior fidelity. Scalp surface recording using electroencephalography is much less precise. BCI technology is still in an early phase of development and awaits further technical improvements and larger multicentre clinical trials before wider clinical application and impact on the care of people with disabilities. There are also many ethical challenges to explore as this technology evolves.

  3. Deterministic entanglement of superconducting qubits by parity measurement and feedback.

    PubMed

    Ristè, D; Dukalski, M; Watson, C A; de Lange, G; Tiggelman, M J; Blanter, Ya M; Lehnert, K W; Schouten, R N; DiCarlo, L

    2013-10-17

    The stochastic evolution of quantum systems during measurement is arguably the most enigmatic feature of quantum mechanics. Measuring a quantum system typically steers it towards a classical state, destroying the coherence of an initial quantum superposition and the entanglement with other quantum systems. Remarkably, the measurement of a shared property between non-interacting quantum systems can generate entanglement, starting from an uncorrelated state. Of special interest in quantum computing is the parity measurement, which projects the state of multiple qubits (quantum bits) to a state with an even or odd number of excited qubits. A parity meter must discern the two qubit-excitation parities with high fidelity while preserving coherence between same-parity states. Despite numerous proposals for atomic, semiconducting and superconducting qubits, realizing a parity meter that creates entanglement for both even and odd measurement results has remained an outstanding challenge. Here we perform a time-resolved, continuous parity measurement of two superconducting qubits using the cavity in a three-dimensional circuit quantum electrodynamics architecture and phase-sensitive parametric amplification. Using postselection, we produce entanglement by parity measurement reaching 88 per cent fidelity to the closest Bell state. Incorporating the parity meter in a feedback-control loop, we transform the entanglement generation from probabilistic to fully deterministic, achieving 66 per cent fidelity to a target Bell state on demand. These realizations of a parity meter and a feedback-enabled deterministic measurement protocol provide key ingredients for active quantum error correction in the solid state.

  4. Electroforming of optical tooling in high-strength Ni-Co alloy

    NASA Astrophysics Data System (ADS)

    Stein, Berl

    2003-05-01

    Plastic optics are often mass produced by injection, compression or injection-compression molding. Optical quality molds can be directly machined in appropriate materials (tool steels, electroless nickel, aluminum, etc.), but much greater cost efficiency can be achieved with electroformed modl inserts. Traditionally, electroforming of optical quality mold inserts has been carried out in nickel, a material much softer than tool steels which, when hardened to 45 - 50 HRc usually exhibit high wear resistance and long service life (hundreds of thousands of impressions per mold). Because of their low hardness (< 20 HRc), nickel molds can produce only tens of thousands of parts before they are scrapped due to wear or accidental damage. This drawback prevented their wider usage in general plastic and optical mold making. Recently, NiCoForm has developed a proprietary Ni-CO electroforming bath combining the high strength and wear resistance of the alloy with the low stress and high replication fidelity typical of pure nickel electroforming. This paper will outline the approach to electroforming of optical quality tooling in low stress, high strength Ni-Co alloy and present several examples of electroformed NiColoy mold inserts.

  5. Creation of a High-fidelity, Low-cost Pediatric Skull Fracture Ultrasound Phantom.

    PubMed

    Soucy, Zachary P; Mills, Lisa; Rose, John S; Kelley, Kenneth; Ramirez, Francisco; Kuppermann, Nathan

    2015-08-01

    Over the past decade, point-of-care ultrasound has become a common tool used for both procedures and diagnosis. Developing high-fidelity phantoms is critical for training in new and novel point-of-care ultrasound applications. Detecting skull fractures on ultrasound imaging in the younger-than-2-year-old patient is an emerging area of point-of-care ultrasound research. Identifying a skull fracture on ultrasound imaging in this age group requires knowledge of the appearance and location of sutures to distinguish them from fractures. There are currently no commercially available pediatric skull fracture models. We outline a novel approach to building a cost-effective, simple, high-fidelity pediatric skull fracture phantom to meet a unique training requirement. © 2015 by the American Institute of Ultrasound in Medicine.

  6. Measuring Implementation Fidelity in a Community-Based Parenting Intervention

    PubMed Central

    Breitenstein, Susan M.; Fogg, Louis; Garvey, Christine; Hill, Carri; Resnick, Barbara; Gross, Deborah

    2012-01-01

    Background Establishing the feasibility and validity of implementation fidelity monitoring strategies is an important methodological step in implementing evidence-based interventions on a large scale. Objectives The objective of the study was to examine the reliability and validity of the Fidelity Checklist, a measure designed to assess group leader adherence and competence delivering a parent training intervention (the Chicago Parent Program) in child care centers serving low-income families. Method The sample included 9 parent groups (12 group sessions each), 12 group leaders, and 103 parents. Independent raters reviewed 106 audiotaped parent group sessions and coded group leaders’ fidelity on the Adherence and Competence Scales of the Fidelity Checklist. Group leaders completed self-report adherence checklists and a measure of parent engagement in the intervention. Parents completed measures of consumer satisfaction and child behavior. Results High interrater agreement (Adherence Scale = 94%, Competence Scale = 85%) and adequate intraclass correlation coefficients (Adherence Scale = .69, Competence Scale = .91) were achieved for the Fidelity Checklist. Group leader adherence changed over time, but competence remained stable. Agreement between group leader self-report and independent ratings on the Adherence Scale was 85%; disagreements were more frequently due to positive bias in group leader self-report. Positive correlations were found between group leader adherence and parent attendance and engagement in the intervention and between group leader competence and parent satisfaction. Although child behavior problems improved, improvements were not related to fidelity. Discussion The results suggest that the Fidelity Checklist is a feasible, reliable, and valid measure of group leader implementation fidelity in a group-based parenting intervention. Future research will be focused on testing the Fidelity Checklist with diverse and larger samples and generalizing to other group-based interventions using a similar intervention model. PMID:20404777

  7. Replica amplification of nucleic acid arrays

    DOEpatents

    Church, George M.; Mitra, Robi D.

    2010-08-31

    Disclosed are improved methods of making and using immobilized arrays of nucleic acids, particularly methods for producing replicas of such arrays. Included are methods for producing high density arrays of nucleic acids and replicas of such arrays, as well as methods for preserving the resolution of arrays through rounds of replication. Also included are methods which take advantage of the availability of replicas of arrays for increased sensitivity in detection of sequences on arrays. Improved methods of sequencing nucleic acids immobilized on arrays utilizing single copies of arrays and methods taking further advantage of the availability of replicas of arrays are disclosed. The improvements lead to higher fidelity and longer read lengths of sequences immobilized on arrays. Methods are also disclosed which improve the efficiency of multiplex PCR using arrays of immobilized nucleic acids.

  8. Digital coding of Shuttle TV

    NASA Technical Reports Server (NTRS)

    Habibi, A.; Batson, B.

    1976-01-01

    Space Shuttle will be using a field-sequential color television system for the first few missions, but the present plans are to switch to a NTSC color TV system for future missions. The field-sequential color TV system uses a modified black and white camera, producing a TV signal with a digital bandwidth of about 60 Mbps. This article discusses the characteristics of the Shuttle TV systems and proposes a bandwidth-compression technique for the field-sequential color TV system that could operate at 13 Mbps to produce a high-fidelity signal. The proposed bandwidth-compression technique is based on a two-dimensional DPCM system that utilizes temporal, spectral, and spatial correlation inherent in the field-sequential color TV imagery. The proposed system requires about 60 watts and less than 200 integrated circuits.

  9. Performance of the SIR-B digital image processing subsystem

    NASA Technical Reports Server (NTRS)

    Curlander, J. C.

    1986-01-01

    A ground-based system to generate digital SAR image products has been developed and implemented in support of the SIR-B mission. This system is designed to achieve the maximum throughput while meeting strict image fidelity criteria. Its capabilities include: automated radiometric and geometric correction of the output imagery; high-precision absolute location without tiepoint registration; filtering of the raw data to remove spurious signals from alien radars; and automated catologing to maintain a full set of radar and image production facility in support of the SIR-B science investigators routinely produces over 80 image frames per week.

  10. iStethoscope: a demonstration of the use of mobile devices for auscultation.

    PubMed

    Bentley, Peter J

    2015-01-01

    iStethoscope Pro is the first piece of software (an "App") produced for iOS devices, which enabled users to exploit their smartphones, music players, or tablets as stethoscopes. The software exploits the built-in microphone (and supports externally added microphones) and performs real-time amplification and filtering to enable heart sounds to be heard with high fidelity. The software also enables the heart sounds to be recorded, analyzed using a spectrogram, and to be transmitted to others via e-mail. This chapter describes the motivation, functionality, and results from this work.

  11. Variance in binary stellar population synthesis

    NASA Astrophysics Data System (ADS)

    Breivik, Katelyn; Larson, Shane L.

    2016-03-01

    In the years preceding LISA, Milky Way compact binary population simulations can be used to inform the science capabilities of the mission. Galactic population simulation efforts generally focus on high fidelity models that require extensive computational power to produce a single simulated population for each model. Each simulated population represents an incomplete sample of the functions governing compact binary evolution, thus introducing variance from one simulation to another. We present a rapid Monte Carlo population simulation technique that can simulate thousands of populations in less than a week, thus allowing a full exploration of the variance associated with a binary stellar evolution model.

  12. Studying Variance in the Galactic Ultra-compact Binary Population

    NASA Astrophysics Data System (ADS)

    Larson, Shane L.; Breivik, Katelyn

    2017-01-01

    In the years preceding LISA, Milky Way compact binary population simulations can be used to inform the science capabilities of the mission. Galactic population simulation efforts generally focus on high fidelity models that require extensive computational power to produce a single simulated population for each model. Each simulated population represents an incomplete sample of the functions governing compact binary evolution, thus introducing variance from one simulation to another. We present a rapid Monte Carlo population simulation technique that can simulate thousands of populations on week-long timescales, thus allowing a full exploration of the variance associated with a binary stellar evolution model.

  13. Generating polarization-entangled photon pairs using cross-spliced birefringent fibers.

    PubMed

    Meyer-Scott, Evan; Roy, Vincent; Bourgoin, Jean-Philippe; Higgins, Brendon L; Shalm, Lynden K; Jennewein, Thomas

    2013-03-11

    We demonstrate a novel polarization-entangled photon-pair source based on standard birefringent polarization-maintaining optical fiber. The source consists of two stretches of fiber spliced together with perpendicular polarization axes, and has the potential to be fully fiber-based, with all bulk optics replaced with in-fiber equivalents. By modelling the temporal walk-off in the fibers, we implement compensation necessary for the photon creation processes in the two stretches of fiber to be indistinguishable. Our source subsequently produces a high quality entangled state having (92.2 ± 0.2) % fidelity with a maximally entangled Bell state.

  14. Development of three-dimensional brain arteriovenous malformation model for patient communication and young neurosurgeon education.

    PubMed

    Dong, Mengqi; Chen, Guangzhong; Qin, Kun; Ding, Xiaowen; Zhou, Dong; Peng, Chao; Zeng, Shaojian; Deng, Xianming

    2018-01-15

    Rapid prototyping technology is used to fabricate three-dimensional (3D) brain arteriovenous malformation (AVM) models and facilitate presurgical patient communication and medical education for young surgeons. Two intracranial AVM cases were selected for this study. Using 3D CT angiography or 3D rotational angiography images, the brain AVM models were reconstructed on personal computer and the rapid prototyping process was completed using a 3D printer. The size and morphology of the models were compared to brain digital subtraction arteriography of the same patients. 3D brain AVM models were used for preoperative patient communication and young neurosurgeon education. Two brain AVM models were successfully produced. By neurosurgeons' evaluation, the printed models have high fidelity with the actual brain AVM structures of the patients. The patient responded positively toward the brain AVM model specific to himself. Twenty surgical residents from residency programs tested the brain AVM models and provided positive feedback on their usefulness as educational tool and resemblance to real brain AVM structures. Patient-specific 3D printed models of brain AVM can be constructed with high fidelity. 3D printed brain AVM models are proved to be helpful in preoperative patient consultation, surgical planning and resident training.

  15. Replication fidelity improvement of PMMA microlens array based on weight evaluation and optimization

    NASA Astrophysics Data System (ADS)

    Jiang, Bing-yan; Shen, Long-jiang; Peng, Hua-jiang; Yin, Xiang-lin

    2007-12-01

    High replication fidelity is a prerequisite of high quality plastic microlens array in injection molding. But, there's not an economical and practical method to evaluate and improve the replication fidelity until now. Based on part weight evaluation and optimization, this paper presents a new method of replication fidelity improvement. Firstly, a simplified analysis model of PMMA micro columns arrays (5×16) with 200μm diameter was set up. And then, Flow (3D) module of Moldflow MPI6.0 based on Navier-Stokes equations was used to calculate the weight of the micro columns arrays in injection molding. The effects of processing parameters (melt temperature, mold temperature, injection time, packing pressure and packing time) on the part weight were investigated in the simulations. The simulation results showed that the mold temperature and the injection time have important effects on the filling of micro columns; the optimal mold temperature and injection time for better replication fidelity could be determined by the curves of mold temperature vs part weight and injection time vs part weight. At last, the effects of processing parameters on part weight of micro columns array were studied experimentally. The experimental results showed that the increase of melt temperature and mold temperature can make the packing pressure transfer to micro cavity more effectively through runner system, and increase the part weight. From the observation results of the image measuring apparatus, it was discovered that the higher the part weight, the better the filling of the microstructures. In conclusion, part weight can be used to evaluate the replication fidelity of micro-feature structured parts primarily; which is an economical and practical method to improve the replication fidelity of microlens arrays based on weight evaluation and optimization.

  16. Housing first on a large scale: Fidelity strengths and challenges in the VA's HUD-VASH program.

    PubMed

    Kertesz, Stefan G; Austin, Erika L; Holmes, Sally K; DeRussy, Aerin J; Van Deusen Lukas, Carol; Pollio, David E

    2017-05-01

    Housing First (HF) combines permanent supportive housing and supportive services for homeless individuals and removes traditional treatment-related preconditions for housing entry. There has been little research describing strengths and shortfalls of HF implementation outside of research demonstration projects. The U.S. Department of Veterans Affairs (VA) has transitioned to an HF approach in a supportive housing program serving over 85,000 persons. This offers a naturalistic window to study fidelity when HF is adopted on a large scale. We operationalized HF into 20 criteria grouped into 5 domains. We assessed 8 VA medical centers twice (1 year apart), scoring each criterion using a scale ranging from 1 ( low fidelity ) to 4 ( high fidelity ). There were 2 HF domains (no preconditions and rapidly offering permanent housing) for which high fidelity was readily attained. There was uneven progress in prioritizing the most vulnerable clients for housing support. Two HF domains (sufficient supportive services and a modern recovery philosophy) had considerably lower fidelity. Interviews suggested that operational issues such as shortfalls in staffing and training likely hindered performance in these 2 domains. In this ambitious national HF program, the largest to date, we found substantial fidelity in focusing on permanent housing and removal of preconditions to housing entry. Areas of concern included the adequacy of supportive services and adequacy in deployment of a modern recovery philosophy. Under real-world conditions, large-scale implementation of HF is likely to require significant additional investment in client service supports to assure that results are concordant with those found in research studies. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. High-Fidelity Design of Multimodal Restorative Interventions in Gulf War Illness

    DTIC Science & Technology

    2017-10-01

    Bockmayr A, Klarner H, Siebert H. Time series dependent analysis of unparametrized Thomas networks. IEEE/ACM Transactions on Computational Biology and...Award Number: W81XWH-15-1-0582 TITLE:High-Fidelity Design of Multimodal Restorative Interventions in Gulf War Illness PRINCIPAL INVESTIGATOR...not be construed as an official Department of the Army position, policy or decision unless so designated by other documentation. REPORT

  18. Effects of High Fidelity Simulation on Knowledge Acquisition, Self-Confidence, and Satisfaction with Baccalaureate Nursing Students Using the Solomon-Four Research Design

    ERIC Educational Resources Information Center

    Hall, Rachel Mattson

    2013-01-01

    High Fidelity Simulation is a teaching strategy that is becoming well-entrenched in the world of nursing education and is rapidly expanding due to the challenges and demands of the health care environment. The problem addressed in this study is the conflicting research results regarding the effectiveness of HFS for students' knowledge acquisition…

  19. Effects of High-Fidelity Human Patient Simulation Experience on Self-Efficacy, Motivation and Learning of First Semester Associate Degree Nursing Students

    ERIC Educational Resources Information Center

    Kuznar, Kathleen A.

    2009-01-01

    One of the newest methodologies in nursing education is high-fidelity human patient simulation (HPS). Many nursing educators have embraced the method as it offers a strategy to facilitate cognitive, affective, and psychomotor outcomes. Despite their popularity, however, HPS systems are costly and, in an era of cost containment and tuition…

  20. SITE FIDELITY AND EPHEMERAL HABITAT OCCUPANCY: NORTHERN WATERTHRUSH USE OF PUERTO RICAN BLACK MANGROVES DURING THE NONBREEDING SEASON.

    Treesearch

    LEONARD REITSMA; PAMELA HUNT; SHERMAN L. BURSON III; BENJAMIN B. STEELE

    2002-01-01

    We studied the dispersion of Northern Waterthrushes (Seiurus novaboracensis) in southwestern Puerto Rico during four nonbreeding seasons, 1996–1999. Densities were high (up to 13 birds/ha) on a 3-ha mature black mangrove (Avicennia germinans) study plot, but were significantly lower during periods of high water levels. Individuals exhibited site fidelity within and...

  1. Comparison of Satisfaction, Self-Confidence, and Engagement of Baccalaureate Nursing Students Using Defined Observational Roles and Expectations versus Traditional Role Assignments in High Fidelity Simulation and Debriefing

    ERIC Educational Resources Information Center

    Howard, Sheri

    2017-01-01

    The purpose of this study is to compare satisfaction, self-confidence, and engagement of baccalaureate nursing students using defined observational roles and expectations versus traditional observer role assignments in high fidelity simulation and debriefing and to evaluate student perceptions of these constructs. The NLN/Jeffries Simulation…

  2. An Evaluation of Immediate Outcomes and Fidelity of a Drug Abuse Prevention Program in Continuation High Schools: Project towards No Drug Abuse (TND)

    ERIC Educational Resources Information Center

    Lisha, Nadra E.; Sun, Ping; Rohrbach, Louise A.; Spruijt-Metz, Donna; Unger, Jennifer B.; Sussman, Steve

    2012-01-01

    The present study provides an implementation fidelity, process, and immediate outcomes evaluation of Project Towards No Drug Abuse (TND), a drug prevention program targeting continuation high school youth (n = 1426) at risk for drug abuse. A total of 24 schools participated in three randomized conditions: TND Only, TND and motivational…

  3. Motivation and Technological Readiness in the Use of High-Fidelity Simulation: A Descriptive Comparative Study of Nurse Educators

    ERIC Educational Resources Information Center

    Duvall, Judy Jo

    2012-01-01

    There are many driving forces to increase the use of high-fidelity simulation (HFS) in nursing education, as well as many factors that may influence the implementation of this teaching strategy. These include the motivation of nurse educators to use HFS, the technological readiness of nurse educators to use HFS and the changing demographics of the…

  4. Evaluation of high fidelity patient simulator in assessment of performance of anaesthetists.

    PubMed

    Weller, J M; Bloch, M; Young, S; Maze, M; Oyesola, S; Wyner, J; Dob, D; Haire, K; Durbridge, J; Walker, T; Newble, D

    2003-01-01

    There is increasing emphasis on performance-based assessment of clinical competence. The High Fidelity Patient Simulator (HPS) may be useful for assessment of clinical practice in anaesthesia, but needs formal evaluation of validity, reliability, feasibility and effect on learning. We set out to assess the reliability of a global rating scale for scoring simulator performance in crisis management. Using a global rating scale, three judges independently rated videotapes of anaesthetists in simulated crises in the operating theatre. Five anaesthetists then independently rated subsets of these videotapes. There was good agreement between raters for medical management, behavioural attributes and overall performance. Agreement was high for both the initial judges and the five additional raters. Using a global scale to assess simulator performance, we found good inter-rater reliability for scoring performance in a crisis. We estimate that two judges should provide a reliable assessment. High fidelity simulation should be studied further for assessing clinical performance.

  5. Enhanced fidelity of an educational intervention on skin self-examination through surveillance and standardization

    PubMed Central

    Gaber, Rikki; Mallett, Kimberly A.; Hultgren, Brittney; Turrisi, Rob; Gilbertsen, Margaret L.; Martini, Mary C.; Robinson, June K.

    2014-01-01

    Background Melanoma can metastasize but is often successfully treated when discovered in an early stage. Melanoma patients and their skin check partners can learn skin self-examination (SSE) skills and these skills can be improved by practice. The purpose of this study is to determine the degree of fidelity with which educational in-person SSE intervention can be delivered by trained research coordinators to patients at risk of developing another melanoma and their skin check partners. Methods The in-person intervention was performed in two iterations. In phase 1 (2006-2008), the research coordinators were trained to perform the intervention using a written script. In phase 2 (2011-2013), the research coordinators were trained to perform the intervention with a PowerPoint aid. Each research coordinator was individually counseled by one of the authors (KM) to insure standardization and enhance fidelity of intervention delivery. Phase 1 and Phase 2 were compared on 16 fidelity components. Further, Phase 2 fidelity was assessed by comparing mean scores of fidelity across the five research coordinators who delivered the intervention. Results Phase 2, which utilized a PowerPoint aid, was delivered with a higher degree of fidelity compared to phase 1with four fidelity components with significantly higher fidelity than Phase 1: 1) Explained details of melanoma, χ2 (1, n = 199)= 96.31, p < .001, 2) Discussed when to call doctor, χ2 (1, n = 199) = 53.68, p < .001 3) Explained assessment at month 1, χ2 (1, n = 199)= 12.39, p < .01, and 4) Explained assessment at month 2, χ2 (1, n = 199) = 117.75, p < .001. Further, no significant differences on mean fidelity were found across research coordinators in Phase 2. Discussion When using the PowerPoint aide, the research coordinators delivered the intervention with high fidelity (all scores >14) and there were no mean differences in fidelity across research coordinators, indicating consistency in fidelity. This can be attributed to the standardization and cueing that the PowerPoint program offered. Supervision was also a key component in establishing and maintaining fidelity of the patient educational process. This method of intervention delivery enables trained healthcare professionals to deliver an educational intervention in an effective, consistent manner. PMID:25414761

  6. Enhanced fidelity of an educational intervention on skin self-examination through surveillance and standardization.

    PubMed

    Gaber, Rikki; Mallett, Kimberly A; Hultgren, Brittney; Turrisi, Rob; Gilbertsen, Margaret L; Martini, Mary C; Robinson, June K

    2014-01-01

    Melanoma can metastasize but is often successfully treated when discovered in an early stage. Melanoma patients and their skin check partners can learn skin self-examination (SSE) skills and these skills can be improved by practice. The purpose of this study is to determine the degree of fidelity with which educational in-person SSE intervention can be delivered by trained research coordinators to patients at risk of developing another melanoma and their skin check partners. The in-person intervention was performed in two iterations. In phase 1 (2006-2008), the research coordinators were trained to perform the intervention using a written script. In phase 2 (2011-2013), the research coordinators were trained to perform the intervention with a PowerPoint aid. Each research coordinator was individually counseled by one of the authors (KM) to insure standardization and enhance fidelity of intervention delivery. Phase 1 and Phase 2 were compared on 16 fidelity components. Further, Phase 2 fidelity was assessed by comparing mean scores of fidelity across the five research coordinators who delivered the intervention. Phase 2, which utilized a PowerPoint aid, was delivered with a higher degree of fidelity compared to phase 1with four fidelity components with significantly higher fidelity than Phase 1: 1) Explained details of melanoma, χ 2 (1, n = 199)= 96.31, p < .001, 2) Discussed when to call doctor, χ 2 (1, n = 199) = 53.68, p < .001 3) Explained assessment at month 1, χ 2 (1, n = 199)= 12.39, p < .01, and 4) Explained assessment at month 2, χ 2 (1, n = 199) = 117.75, p < .001. Further, no significant differences on mean fidelity were found across research coordinators in Phase 2. When using the PowerPoint aide, the research coordinators delivered the intervention with high fidelity (all scores >14) and there were no mean differences in fidelity across research coordinators, indicating consistency in fidelity. This can be attributed to the standardization and cueing that the PowerPoint program offered. Supervision was also a key component in establishing and maintaining fidelity of the patient educational process. This method of intervention delivery enables trained healthcare professionals to deliver an educational intervention in an effective, consistent manner.

  7. Attenuation of Foot-and-Mouth Disease Virus by Engineered Viral Polymerase Fidelity.

    PubMed

    Rai, Devendra K; Diaz-San Segundo, Fayna; Campagnola, Grace; Keith, Anna; Schafer, Elizabeth A; Kloc, Anna; de Los Santos, Teresa; Peersen, Olve; Rieder, Elizabeth

    2017-08-01

    Foot-and-mouth disease virus (FMDV) RNA-dependent RNA polymerase (RdRp) (3D pol ) catalyzes viral RNA synthesis. Its characteristic low fidelity and absence of proofreading activity allow FMDV to rapidly mutate and adapt to dynamic environments. In this study, we used the structure of FMDV 3D pol in combination with previously reported results from similar picornaviral polymerases to design point mutations that would alter replication fidelity. In particular, we targeted Trp237 within conserved polymerase motif A because of the low reversion potential inherent in the single UGG codon. Using biochemical and genetic tools, we show that the replacement of tryptophan 237 with phenylalanine imparts higher fidelity, but replacements with isoleucine and leucine resulted in lower-fidelity phenotypes. Viruses containing these W237 substitutions show in vitro growth kinetics and plaque morphologies similar to those of the wild-type (WT) A 24 Cruzeiro strain in BHK cells, and both high- and low-fidelity variants retained fitness during coinfection with the wild-type virus. The higher-fidelity W237F (W237F HF ) mutant virus was more resistant to the mutagenic nucleoside analogs ribavirin and 5-fluorouracil than the WT virus, whereas the lower-fidelity W237I (W237I LF ) and W237L LF mutant viruses exhibited lower ribavirin resistance. Interestingly, the variant viruses showed heterogeneous and slightly delayed growth kinetics in primary porcine kidney cells, and they were significantly attenuated in mouse infection experiments. These data demonstrate, for a single virus, that either increased or decreased RdRp fidelity attenuates virus growth in animals, which is a desirable feature for the development of safer and genetically more stable vaccine candidates. IMPORTANCE Foot-and-mouth disease (FMD) is the most devastating disease affecting livestock worldwide. Here, using structural and biochemical analyses, we have identified FMDV 3D pol mutations that affect polymerase fidelity. Recombinant FMDVs containing substitutions at 3D pol tryptophan residue 237 were genetically stable and displayed plaque phenotypes and growth kinetics similar to those of the wild-type virus in cell culture. We further demonstrate that viruses harboring either a W237F HF substitution or W237I LF and W237L LF mutations were highly attenuated in animals. Our study shows that obtaining 3D pol fidelity variants by protein engineering based on polymerase structure and function could be exploited for the development of attenuated FMDV vaccine candidates that are safer and more stable than strains obtained by selective pressure via mutagenic nucleotides or adaptation approaches. Copyright © 2017 American Society for Microbiology.

  8. Attenuation of Foot-and-Mouth Disease Virus by Engineered Viral Polymerase Fidelity

    PubMed Central

    Rai, Devendra K.; Diaz-San Segundo, Fayna; Campagnola, Grace; Keith, Anna; Schafer, Elizabeth A.; Kloc, Anna; de los Santos, Teresa; Peersen, Olve

    2017-01-01

    ABSTRACT Foot-and-mouth disease virus (FMDV) RNA-dependent RNA polymerase (RdRp) (3Dpol) catalyzes viral RNA synthesis. Its characteristic low fidelity and absence of proofreading activity allow FMDV to rapidly mutate and adapt to dynamic environments. In this study, we used the structure of FMDV 3Dpol in combination with previously reported results from similar picornaviral polymerases to design point mutations that would alter replication fidelity. In particular, we targeted Trp237 within conserved polymerase motif A because of the low reversion potential inherent in the single UGG codon. Using biochemical and genetic tools, we show that the replacement of tryptophan 237 with phenylalanine imparts higher fidelity, but replacements with isoleucine and leucine resulted in lower-fidelity phenotypes. Viruses containing these W237 substitutions show in vitro growth kinetics and plaque morphologies similar to those of the wild-type (WT) A24 Cruzeiro strain in BHK cells, and both high- and low-fidelity variants retained fitness during coinfection with the wild-type virus. The higher-fidelity W237F (W237FHF) mutant virus was more resistant to the mutagenic nucleoside analogs ribavirin and 5-fluorouracil than the WT virus, whereas the lower-fidelity W237I (W237ILF) and W237LLF mutant viruses exhibited lower ribavirin resistance. Interestingly, the variant viruses showed heterogeneous and slightly delayed growth kinetics in primary porcine kidney cells, and they were significantly attenuated in mouse infection experiments. These data demonstrate, for a single virus, that either increased or decreased RdRp fidelity attenuates virus growth in animals, which is a desirable feature for the development of safer and genetically more stable vaccine candidates. IMPORTANCE Foot-and-mouth disease (FMD) is the most devastating disease affecting livestock worldwide. Here, using structural and biochemical analyses, we have identified FMDV 3Dpol mutations that affect polymerase fidelity. Recombinant FMDVs containing substitutions at 3Dpol tryptophan residue 237 were genetically stable and displayed plaque phenotypes and growth kinetics similar to those of the wild-type virus in cell culture. We further demonstrate that viruses harboring either a W237FHF substitution or W237ILF and W237LLF mutations were highly attenuated in animals. Our study shows that obtaining 3Dpol fidelity variants by protein engineering based on polymerase structure and function could be exploited for the development of attenuated FMDV vaccine candidates that are safer and more stable than strains obtained by selective pressure via mutagenic nucleotides or adaptation approaches. PMID:28515297

  9. Coordinating DNA polymerase traffic during high and low fidelity synthesis.

    PubMed

    Sutton, Mark D

    2010-05-01

    With the discovery that organisms possess multiple DNA polymerases (Pols) displaying different fidelities, processivities, and activities came the realization that mechanisms must exist to manage the actions of these diverse enzymes to prevent gratuitous mutations. Although many of the Pols encoded by most organisms are largely accurate, and participate in DNA replication and DNA repair, a sizeable fraction display a reduced fidelity, and act to catalyze potentially error-prone translesion DNA synthesis (TLS) past lesions that persist in the DNA. Striking the proper balance between use of these different enzymes during DNA replication, DNA repair, and TLS is essential for ensuring accurate duplication of the cell's genome. This review highlights mechanisms that organisms utilize to manage the actions of their different Pols. A particular emphasis is placed on discussion of current models for how different Pols switch places with each other at the replication fork during high fidelity replication and potentially error-pone TLS. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. The Simplified Aircraft-Based Paired Approach With the ALAS Alerting Algorithm

    NASA Technical Reports Server (NTRS)

    Perry, Raleigh B.; Madden, Michael M.; Torres-Pomales, Wilfredo; Butler, Ricky W.

    2013-01-01

    This paper presents the results of an investigation of a proposed concept for closely spaced parallel runways called the Simplified Aircraft-based Paired Approach (SAPA). This procedure depends upon a new alerting algorithm called the Adjacent Landing Alerting System (ALAS). This study used both low fidelity and high fidelity simulations to validate the SAPA procedure and test the performance of the new alerting algorithm. The low fidelity simulation enabled a determination of minimum approach distance for the worst case over millions of scenarios. The high fidelity simulation enabled an accurate determination of timings and minimum approach distance in the presence of realistic trajectories, communication latencies, and total system error for 108 test cases. The SAPA procedure and the ALAS alerting algorithm were applied to the 750-ft parallel spacing (e.g., SFO 28L/28R) approach problem. With the SAPA procedure as defined in this paper, this study concludes that a 750-ft application does not appear to be feasible, but preliminary results for 1000-ft parallel runways look promising.

  11. Critical thinking skills in nursing students: comparison of simulation-based performance with metrics.

    PubMed

    Fero, Laura J; O'Donnell, John M; Zullo, Thomas G; Dabbs, Annette DeVito; Kitutu, Julius; Samosky, Joseph T; Hoffman, Leslie A

    2010-10-01

    This paper is a report of an examination of the relationship between metrics of critical thinking skills and performance in simulated clinical scenarios. Paper and pencil assessments are commonly used to assess critical thinking but may not reflect simulated performance. In 2007, a convenience sample of 36 nursing students participated in measurement of critical thinking skills and simulation-based performance using videotaped vignettes, high-fidelity human simulation, the California Critical Thinking Disposition Inventory and California Critical Thinking Skills Test. Simulation-based performance was rated as 'meeting' or 'not meeting' overall expectations. Test scores were categorized as strong, average, or weak. Most (75.0%) students did not meet overall performance expectations using videotaped vignettes or high-fidelity human simulation; most difficulty related to problem recognition and reporting findings to the physician. There was no difference between overall performance based on method of assessment (P = 0.277). More students met subcategory expectations for initiating nursing interventions (P ≤ 0.001) using high-fidelity human simulation. The relationship between videotaped vignette performance and critical thinking disposition or skills scores was not statistically significant, except for problem recognition and overall critical thinking skills scores (Cramer's V = 0.444, P = 0.029). There was a statistically significant relationship between overall high-fidelity human simulation performance and overall critical thinking disposition scores (Cramer's V = 0.413, P = 0.047). Students' performance reflected difficulty meeting expectations in simulated clinical scenarios. High-fidelity human simulation performance appeared to approximate scores on metrics of critical thinking best. Further research is needed to determine if simulation-based performance correlates with critical thinking skills in the clinical setting. © 2010 The Authors. Journal of Advanced Nursing © 2010 Blackwell Publishing Ltd.

  12. Critical thinking skills in nursing students: comparison of simulation-based performance with metrics

    PubMed Central

    Fero, Laura J.; O’Donnell, John M.; Zullo, Thomas G.; Dabbs, Annette DeVito; Kitutu, Julius; Samosky, Joseph T.; Hoffman, Leslie A.

    2018-01-01

    Aim This paper is a report of an examination of the relationship between metrics of critical thinking skills and performance in simulated clinical scenarios. Background Paper and pencil assessments are commonly used to assess critical thinking but may not reflect simulated performance. Methods In 2007, a convenience sample of 36 nursing students participated in measurement of critical thinking skills and simulation-based performance using videotaped vignettes, high-fidelity human simulation, the California Critical Thinking Disposition Inventory and California Critical Thinking Skills Test. Simulation- based performance was rated as ‘meeting’ or ‘not meeting’ overall expectations. Test scores were categorized as strong, average, or weak. Results Most (75·0%) students did not meet overall performance expectations using videotaped vignettes or high-fidelity human simulation; most difficulty related to problem recognition and reporting findings to the physician. There was no difference between overall performance based on method of assessment (P = 0·277). More students met subcategory expectations for initiating nursing interventions (P ≤ 0·001) using high-fidelity human simulation. The relationship between video-taped vignette performance and critical thinking disposition or skills scores was not statistically significant, except for problem recognition and overall critical thinking skills scores (Cramer’s V = 0·444, P = 0·029). There was a statistically significant relationship between overall high-fidelity human simulation performance and overall critical thinking disposition scores (Cramer’s V = 0·413, P = 0·047). Conclusion Students’ performance reflected difficulty meeting expectations in simulated clinical scenarios. High-fidelity human simulation performance appeared to approximate scores on metrics of critical thinking best. Further research is needed to determine if simulation-based performance correlates with critical thinking skills in the clinical setting. PMID:20636471

  13. High-fidelity simulation of transcutaneous cardiac pacing: characteristics and limitations of available high-fidelity simulators, and description of an alternative two-mannequin model.

    PubMed

    Robitaille, Arnaud; Perron, Roger; Germain, Jean-François; Tanoubi, Issam; Georgescu, Mihai

    2015-04-01

    Transcutaneous cardiac pacing (TCP) is a potentially lifesaving technique that is part of the recommended treatment for symptomatic bradycardia. Transcutaneous cardiac pacing however is used uncommonly, and its successful application is not straightforward. Simulation could, therefore, play an important role in the teaching and assessment of TCP competence. However, even the highest-fidelity mannequins available on the market have important shortcomings, which limit the potential of simulation. Six criteria defining clinical competency in TCP were established and used as a starting point in the creation of an improved TCP simulator. The goal was a model that could be used to assess experienced clinicians, an objective that justifies the additional effort required by the increased fidelity. The proposed 2-mannequin model (TMM) combines a highly modified Human Patient Simulator with a SimMan 3G, the latter being used solely to provide the electrocardiography (ECG) tracing. The TMM improves the potential of simulation to assess experienced clinicians (1) by reproducing key features of TCP, like using the same multifunctional pacing electrodes used clinically, allowing dual ECG monitoring, and responding with upper body twitching when stimulated, but equally importantly (2) by reproducing key pitfalls of the technique, like allowing pacing electrode misplacement and reproducing false signs of ventricular capture, commonly, but erroneously, used clinically to establish that effective pacing has been achieved (like body twitching, electrical artifact on the ECG, and electrical capture without ventricular capture). The proposed TMM uses a novel combination of 2 high-fidelity mannequins to improve TCP simulation until upgraded mannequins become commercially available.

  14. Hybrid spectral CT reconstruction

    PubMed Central

    Clark, Darin P.

    2017-01-01

    Current photon counting x-ray detector (PCD) technology faces limitations associated with spectral fidelity and photon starvation. One strategy for addressing these limitations is to supplement PCD data with high-resolution, low-noise data acquired with an energy-integrating detector (EID). In this work, we propose an iterative, hybrid reconstruction technique which combines the spectral properties of PCD data with the resolution and signal-to-noise characteristics of EID data. Our hybrid reconstruction technique is based on an algebraic model of data fidelity which substitutes the EID data into the data fidelity term associated with the PCD reconstruction, resulting in a joint reconstruction problem. Within the split Bregman framework, these data fidelity constraints are minimized subject to additional constraints on spectral rank and on joint intensity-gradient sparsity measured between the reconstructions of the EID and PCD data. Following a derivation of the proposed technique, we apply it to the reconstruction of a digital phantom which contains realistic concentrations of iodine, barium, and calcium encountered in small-animal micro-CT. The results of this experiment suggest reliable separation and detection of iodine at concentrations ≥ 5 mg/ml and barium at concentrations ≥ 10 mg/ml in 2-mm features for EID and PCD data reconstructed with inherent spatial resolutions of 176 μm and 254 μm, respectively (point spread function, FWHM). Furthermore, hybrid reconstruction is demonstrated to enhance spatial resolution within material decomposition results and to improve low-contrast detectability by as much as 2.6 times relative to reconstruction with PCD data only. The parameters of the simulation experiment are based on an in vivo micro-CT experiment conducted in a mouse model of soft-tissue sarcoma. Material decomposition results produced from this in vivo data demonstrate the feasibility of distinguishing two K-edge contrast agents with a spectral separation on the order of the energy resolution of the PCD hardware. PMID:28683124

  15. Simulator technology as a tool for education in cardiac care.

    PubMed

    Hravnak, Marilyn; Beach, Michael; Tuite, Patricia

    2007-01-01

    Assisting nurses in gaining the cognitive and psychomotor skills necessary to safely and effectively care for patients with cardiovascular disease can be challenging for educators. Ideally, nurses would have the opportunity to synthesize and practice these skills in a protected training environment before application in the dynamic clinical setting. Recently, a technology known as high fidelity human simulation was introduced, which permits learners to interact with a simulated patient. The dynamic physiologic parameters and physical assessment capabilities of the simulated patient provide for a realistic learning environment. This article describes the High Fidelity Human Simulation Laboratory at the University of Pittsburgh School of Nursing and presents strategies for using this technology as a tool in teaching complex cardiac nursing care at the basic and advanced practice nursing levels. The advantages and disadvantages of high fidelity human simulation in learning are discussed.

  16. Autonomous Aerobraking: Thermal Analysis and Response Surface Development

    NASA Technical Reports Server (NTRS)

    Dec, John A.; Thornblom, Mark N.

    2011-01-01

    A high-fidelity thermal model of the Mars Reconnaissance Orbiter was developed for use in an autonomous aerobraking simulation study. Response surface equations were derived from the high-fidelity thermal model and integrated into the autonomous aerobraking simulation software. The high-fidelity thermal model was developed using the Thermal Desktop software and used in all phases of the analysis. The use of Thermal Desktop exclusively, represented a change from previously developed aerobraking thermal analysis methodologies. Comparisons were made between the Thermal Desktop solutions and those developed for the previous aerobraking thermal analyses performed on the Mars Reconnaissance Orbiter during aerobraking operations. A variable sensitivity screening study was performed to reduce the number of variables carried in the response surface equations. Thermal analysis and response surface equation development were performed for autonomous aerobraking missions at Mars and Venus.

  17. Band-selective shaped pulse for high fidelity quantum control in diamond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Yan-Chun; Xing, Jian; Liu, Gang-Qin

    High fidelity quantum control of qubits is crucially important for realistic quantum computing, and it becomes more challenging when there are inevitable interactions between qubits. We introduce a band-selective shaped pulse, refocusing BURP (REBURP) pulse, to cope with the problems. The electron spin of nitrogen-vacancy centers in diamond is flipped with high fidelity by the REBURP pulse. In contrast with traditional rectangular pulses, the shaped pulse has almost equal excitation effect in a sharply edged region (in frequency domain). So the three sublevels of host {sup 14}N nuclear spin can be flipped accurately simultaneously, while unwanted excitations of other sublevelsmore » (e.g., of a nearby {sup 13}C nuclear spin) is well suppressed. Our scheme can be used for various applications such as quantum metrology, quantum sensing, and quantum information process.« less

  18. Experimental demonstration of high fidelity entanglement distribution over decoherence channels via qubit transduction.

    PubMed

    Lim, Hyang-Tag; Hong, Kang-Hee; Kim, Yoon-Ho

    2015-10-21

    Quantum coherence and entanglement, which are essential resources for quantum information, are often degraded and lost due to decoherence. Here, we report a proof-of-principle experimental demonstration of high fidelity entanglement distribution over decoherence channels via qubit transduction. By unitarily switching the initial qubit encoding to another, which is insensitive to particular forms of decoherence, we have demonstrated that it is possible to avoid the effect of decoherence completely. In particular, we demonstrate high-fidelity distribution of photonic polarization entanglement over quantum channels with two types of decoherence, amplitude damping and polarization-mode dispersion, via qubit transduction between polarization qubits and dual-rail qubits. These results represent a significant breakthrough in quantum communication over decoherence channels as the protocol is input-state independent, requires no ancillary photons and symmetries, and has near-unity success probability.

  19. Experimental demonstration of high fidelity entanglement distribution over decoherence channels via qubit transduction

    PubMed Central

    Lim, Hyang-Tag; Hong, Kang-Hee; Kim, Yoon-Ho

    2015-01-01

    Quantum coherence and entanglement, which are essential resources for quantum information, are often degraded and lost due to decoherence. Here, we report a proof-of-principle experimental demonstration of high fidelity entanglement distribution over decoherence channels via qubit transduction. By unitarily switching the initial qubit encoding to another, which is insensitive to particular forms of decoherence, we have demonstrated that it is possible to avoid the effect of decoherence completely. In particular, we demonstrate high-fidelity distribution of photonic polarization entanglement over quantum channels with two types of decoherence, amplitude damping and polarization-mode dispersion, via qubit transduction between polarization qubits and dual-rail qubits. These results represent a significant breakthrough in quantum communication over decoherence channels as the protocol is input-state independent, requires no ancillary photons and symmetries, and has near-unity success probability. PMID:26487083

  20. SOWFA Super-Controller: A High-Fidelity Tool for Evaluating Wind Plant Control Approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, P.; Gebraad, P.; van Wingerden, J. W.

    2013-01-01

    This paper presents a new tool for testing wind plant controllers in the Simulator for Offshore Wind Farm Applications (SOWFA). SOWFA is a high-fidelity simulator for the interaction between wind turbine dynamics and the fluid flow in a wind plant. The new super-controller testing environment in SOWFA allows for the implementation of the majority of the wind plant control strategies proposed in the literature.

  1. Simulation Learning: PC-Screen Based (PCSB) versus High Fidelity Simulation (HFS)

    DTIC Science & Technology

    2012-08-01

    methods for the use of simulation for teaching clinical skills to military and civilian clinicians . High fidelity simulation is an expensive method of...without the knowledge and approval of the IRB. Changes include, but not limited to, modifications in study design, recruitment process and number of...Person C-Collar simulation algorithm Pathway A Scenario A - Spinal stabilization: Sub processes Legend: Pathway Points Complex task to be performed by

  2. Compact Single Site Resolution Cold Atom Experiment for Adiabatic Quantum Computing

    DTIC Science & Technology

    2016-02-03

    goal of our scientific investigation is to demonstrate high fidelity and fast atom-atom entanglement between physically 1. REPORT DATE (DD-MM-YYYY) 4...of our scientific investigation is to demonstrate high fidelity and fast atom-atom entanglement between physically separated and optically addressed...Specifically, we will design and construct a set of compact single atom traps with integrated optics, suitable for heralded entanglement and loophole

  3. High-fidelity patient simulation in nursing education: an integrative review.

    PubMed

    Weaver, Amy

    2011-01-01

    An integrative review was undertaken to analyze studies published since 1998 on the use of high-fidelity patient simulation (HFPS) in undergraduate nursing education. This review found that HFPS benefits nursing students in terms of knowledge, value, realism, and learner satisfaction;findings were mixed in the areas of student confidence, knowledge transfer, and stress. Further research in these and other areas will determine whether its increased use is warranted.

  4. gr-MRI: A software package for magnetic resonance imaging using software defined radios

    NASA Astrophysics Data System (ADS)

    Hasselwander, Christopher J.; Cao, Zhipeng; Grissom, William A.

    2016-09-01

    The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5 Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately 2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR's ability to generate frequency-swept RF waveforms was validated and compared to the scanner's commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500 kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs.

  5. High Fidelity Processing and Activation of the Human α-Defensin HNP1 Precursor by Neutrophil Elastase and Proteinase 3

    PubMed Central

    Tongaonkar, Prasad; Golji, Amir E.; Tran, Patti; Ouellette, André J.; Selsted, Michael E.

    2012-01-01

    The azurophilic granules of human neutrophils contain four α-defensins called human neutrophil peptides (HNPs 1–4). HNPs are tridisulfide-linked antimicrobial peptides involved in the intracellular killing of organisms phagocytosed by neutrophils. The peptides are produced as inactive precursors (proHNPs) which are processed to active microbicides by as yet unidentified convertases. ProHNP1 was expressed in E. coli and the affinity-purified propeptide isolated as two species, one containing mature HNP1 sequence with native disulfide linkages (“folded proHNP1”) and the other containing non-native disulfide linked proHNP1 conformers (misfolded proHNP1). Native HNP1, liberated by CNBr treatment of folded proHNP1, was microbicidal against Staphylococcus aureus, but the peptide derived from misfolded proHNP1 was inactive. We hypothesized that neutrophil elastase (NE), proteinase 3 (PR3) or cathepsin G (CG), serine proteases that co-localize with HNPs in azurophil granules, are proHNP1 activating convertases. Folded proHNP1 was converted to mature HNP1 by both NE and PR3, but CG generated an HNP1 variant with an N-terminal dipeptide extension. NE and PR3 cleaved folded proHNP1 to produce a peptide indistinguishable from native HNP1 purified from neutrophils, and the microbicidal activities of in vitro derived and natural HNP1 peptides were equivalent. In contrast, misfolded proHNP1 conformers were degraded extensively under the same conditions. Thus, NE and PR3 possess proHNP1 convertase activity that requires the presence of the native HNP1 disulfide motif for high fidelity activation of the precursor in vitro. PMID:22448222

  6. High fidelity processing and activation of the human α-defensin HNP1 precursor by neutrophil elastase and proteinase 3.

    PubMed

    Tongaonkar, Prasad; Golji, Amir E; Tran, Patti; Ouellette, André J; Selsted, Michael E

    2012-01-01

    The azurophilic granules of human neutrophils contain four α-defensins called human neutrophil peptides (HNPs 1-4). HNPs are tridisulfide-linked antimicrobial peptides involved in the intracellular killing of organisms phagocytosed by neutrophils. The peptides are produced as inactive precursors (proHNPs) which are processed to active microbicides by as yet unidentified convertases. ProHNP1 was expressed in E. coli and the affinity-purified propeptide isolated as two species, one containing mature HNP1 sequence with native disulfide linkages ("folded proHNP1") and the other containing non-native disulfide linked proHNP1 conformers (misfolded proHNP1). Native HNP1, liberated by CNBr treatment of folded proHNP1, was microbicidal against Staphylococcus aureus, but the peptide derived from misfolded proHNP1 was inactive. We hypothesized that neutrophil elastase (NE), proteinase 3 (PR3) or cathepsin G (CG), serine proteases that co-localize with HNPs in azurophil granules, are proHNP1 activating convertases. Folded proHNP1 was converted to mature HNP1 by both NE and PR3, but CG generated an HNP1 variant with an N-terminal dipeptide extension. NE and PR3 cleaved folded proHNP1 to produce a peptide indistinguishable from native HNP1 purified from neutrophils, and the microbicidal activities of in vitro derived and natural HNP1 peptides were equivalent. In contrast, misfolded proHNP1 conformers were degraded extensively under the same conditions. Thus, NE and PR3 possess proHNP1 convertase activity that requires the presence of the native HNP1 disulfide motif for high fidelity activation of the precursor in vitro.

  7. Rapidly reconfigurable high-fidelity optical arbitrary waveform generation in heterogeneous photonic integrated circuits.

    PubMed

    Feng, Shaoqi; Qin, Chuan; Shang, Kuanping; Pathak, Shibnath; Lai, Weicheng; Guan, Binbin; Clements, Matthew; Su, Tiehui; Liu, Guangyao; Lu, Hongbo; Scott, Ryan P; Ben Yoo, S J

    2017-04-17

    This paper demonstrates rapidly reconfigurable, high-fidelity optical arbitrary waveform generation (OAWG) in a heterogeneous photonic integrated circuit (PIC). The heterogeneous PIC combines advantages of high-speed indium phosphide (InP) modulators and low-loss, high-contrast silicon nitride (Si3N4) arrayed waveguide gratings (AWGs) so that high-fidelity optical waveform syntheses with rapid waveform updates are possible. The generated optical waveforms spanned a 160 GHz spectral bandwidth starting from an optical frequency comb consisting of eight comb lines separated by 20 GHz channel spacing. The Error Vector Magnitude (EVM) values of the generated waveforms were approximately 16.4%. The OAWG module can rapidly and arbitrarily reconfigure waveforms upon every pulse arriving at 2 ns repetition time. The result of this work indicates the feasibility of truly dynamic optical arbitrary waveform generation where the reconfiguration rate or the modulator bandwidth must exceed the channel spacing of the AWG and the optical frequency comb.

  8. High-fidelity spin entanglement using optimal control.

    PubMed

    Dolde, Florian; Bergholm, Ville; Wang, Ya; Jakobi, Ingmar; Naydenov, Boris; Pezzagna, Sébastien; Meijer, Jan; Jelezko, Fedor; Neumann, Philipp; Schulte-Herbrüggen, Thomas; Biamonte, Jacob; Wrachtrup, Jörg

    2014-02-28

    Precise control of quantum systems is of fundamental importance in quantum information processing, quantum metrology and high-resolution spectroscopy. When scaling up quantum registers, several challenges arise: individual addressing of qubits while suppressing cross-talk, entangling distant nodes and decoupling unwanted interactions. Here we experimentally demonstrate optimal control of a prototype spin qubit system consisting of two proximal nitrogen-vacancy centres in diamond. Using engineered microwave pulses, we demonstrate single electron spin operations with a fidelity F≈0.99. With additional dynamical decoupling techniques, we further realize high-quality, on-demand entangled states between two electron spins with F>0.82, mostly limited by the coherence time and imperfect initialization. Crosstalk in a crowded spectrum and unwanted dipolar couplings are simultaneously eliminated to a high extent. Finally, by high-fidelity entanglement swapping to nuclear spin quantum memory, we demonstrate nuclear spin entanglement over a length scale of 25 nm. This experiment underlines the importance of optimal control for scalable room temperature spin-based quantum information devices.

  9. Validation of a Low-Thrust Mission Design Tool Using Operational Navigation Software

    NASA Technical Reports Server (NTRS)

    Englander, Jacob A.; Knittel, Jeremy M.; Williams, Ken; Stanbridge, Dale; Ellison, Donald H.

    2017-01-01

    Design of flight trajectories for missions employing solar electric propulsion requires a suitably high-fidelity design tool. In this work, the Evolutionary Mission Trajectory Generator (EMTG) is presented as a medium-high fidelity design tool that is suitable for mission proposals. EMTG is validated against the high-heritage deep-space navigation tool MIRAGE, demonstrating both the accuracy of EMTG's model and an operational mission design and navigation procedure using both tools. The validation is performed using a benchmark mission to the Jupiter Trojans.

  10. Intervention Fidelity in Family-Based Prevention Counseling for Adolescent Problem Behaviors

    ERIC Educational Resources Information Center

    Hogue, Aaron; Liddle, Howard A.; Singer, Alisa; Leckrone, Jodi

    2005-01-01

    This study examined fidelity in multidimensional family prevention (MDFP), a family-based prevention counseling model for adolescents at high risk for substance abuse and related behavior problems, in comparison to two empirically based treatments for adolescent drug abuse: multidimensional family therapy (MDFT) and cognitive-behavioral therapy…

  11. Progress towards a microwave-based high-fidelity Toffoli gate with superconducting qubits

    NASA Astrophysics Data System (ADS)

    Rigetti, Chad; Chow, Jerry; Corcoles, Antonio; Rozen, Jim; Keefe, George; Rothwell, Mary Beth; Rohrs, Jack; Borstelmann, Mark; Divincenzo, David; Ketchen, Mark; Steffen, Matthias

    2011-03-01

    We describe recent progress at IBM towards a microwave-based implementation of the Toffoli gate using three capacitively shunted flux qubits dispersively coupled to a resonator. We discuss the device architecture and the microwave protocol, along with expected limits to gate fidelity and scaling.

  12. Effect of improving the realism of simulated clinical judgement tasks on nurses' overconfidence and underconfidence: evidence from a comparative confidence calibration analysis.

    PubMed

    Yang, Huiqin; Thompson, Carl; Bland, Martin

    2012-12-01

    Apparent overconfidence and underconfidence in clinicians making clinical judgements could be a feature of evaluative research designs that fail to accurately represent clinical environments. To test the effect of improved realism of clinical judgement tasks on confidence calibration performance of nurses and student nurses. A comparative confidence calibration analysis. The study was conducted in a large university of Northern England. Ninety-seven participants rated their confidence - using a scale that ranged from 0 (no confidence) to 100 (totally confident) on dichotomous clinical judgements of critical event risk. The judgements were in response to 25 paper-based and 25 higher fidelity scenarios using a computerised patient simulator and clinical equipment. Scenarios, and judgement criteria of 'correctness', were generated from real patient cases. Using a series of calibration measures (calibration, resolution and over/underconfidence), participants' confidence was calibrated against the proportion of correct judgements. The calibration measures generated by the paper-based and high fidelity clinical simulation conditions were compared. Participants made significantly less accurate clinical judgements of risk in the high fidelity clinical simulations compared to the paper simulations (P=0.0002). They were significantly less confident in high fidelity clinical simulations than paper simulations (P=0.03). However, there was no significant difference of over/underconfidence for participants between the two simulated settings (P=0.06). Participants were no better calibrated in the high fidelity clinical simulations than paper simulations, P=0.85. Likewise, participants had no better ability of discriminating correct judgements from incorrect judgements as measured by the resolution statistic in high fidelity clinical simulations than paper simulations, P=0.76. Improving the realism of simulated judgement tasks led to reduced confidence and judgement accuracy in participants but did not alter confidence calibration. These findings suggest that judgemental miscalibration of confidence in nurses may be a systematic cognitive bias and that simply making scenarios more realistic may not be a sufficient condition for correction. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Short-term prey field lability constrains individual specialisation in resource selection and foraging site fidelity in a marine predator.

    PubMed

    Courbin, Nicolas; Besnard, Aurélien; Péron, Clara; Saraux, Claire; Fort, Jérôme; Perret, Samuel; Tornos, Jérémy; Grémillet, David

    2018-04-16

    Spatio-temporally stable prey distributions coupled with individual foraging site fidelity are predicted to favour individual resource specialisation. Conversely, predators coping with dynamic prey distributions should diversify their individual diet and/or shift foraging areas to increase net intake. We studied individual specialisation in Scopoli's shearwaters (Calonectris diomedea) from the highly dynamic Western Mediterranean, using daily prey distributions together with resource selection, site fidelity and trophic-level analyses. As hypothesised, we found dietary diversification, low foraging site fidelity and almost no individual specialisation in resource selection. Crucially, shearwaters switched daily foraging tactics, selecting areas with contrasting prey of varying trophic levels. Overall, information use and plastic resource selection of individuals with reduced short-term foraging site fidelity allow predators to overcome prey field lability. Our study is an essential step towards a better understanding of individual responses to enhanced environmental stochasticity driven by global changes, and of pathways favouring population persistence. © 2018 John Wiley & Sons Ltd/CNRS.

  14. Space Launch System Ascent Static Aerodynamic Database Development

    NASA Technical Reports Server (NTRS)

    Pinier, Jeremy T.; Bennett, David W.; Blevins, John A.; Erickson, Gary E.; Favaregh, Noah M.; Houlden, Heather P.; Tomek, William G.

    2014-01-01

    This paper describes the wind tunnel testing work and data analysis required to characterize the static aerodynamic environment of NASA's Space Launch System (SLS) ascent portion of flight. Scaled models of the SLS have been tested in transonic and supersonic wind tunnels to gather the high fidelity data that is used to build aerodynamic databases. A detailed description of the wind tunnel test that was conducted to produce the latest version of the database is presented, and a representative set of aerodynamic data is shown. The wind tunnel data quality remains very high, however some concerns with wall interference effects through transonic Mach numbers are also discussed. Post-processing and analysis of the wind tunnel dataset are crucial for the development of a formal ascent aerodynamics database.

  15. Preparing and probing many-body correlated systems in a Quantum Gas Microscope by engineering arbitrary landscape potentials

    NASA Astrophysics Data System (ADS)

    Rispoli, Matthew; Lukin, Alexander; Ma, Ruichao; Preiss, Philipp; Tai, M. Eric; Islam, Rajibul; Greiner, Markus

    2015-05-01

    Ultracold atoms in optical lattices provide a versatile tool box for observing the emergence of strongly correlated physics in quantum systems. Dynamic control of optical potentials on the single-site level allows us to prepare and probe many-body quantum states through local Hamiltonian engineering. We achieve these high precision levels of optical control through spatial light modulation with a DMD (digital micro-mirror device). This allows for both arbitrary beam shaping and aberration compensation in our imaging system to produce high fidelity optical potentials. We use these techniques to control state initialization, Hamiltonian dynamics, and measurement in experiments investigating low-dimensional many-body physics - from one-dimensional correlated quantum walks to characterizing entanglement.

  16. Assessment of clonal fidelity of Tylophora indica (Burm. f.) Merrill "in vitro" plantlets by ISSR molecular markers.

    PubMed

    Sharma, Madan Mohan; Verma, Roop Narayan; Singh, Abhijeet; Batra, Amla

    2014-01-01

    Tylophora indica Burm F. Merrill. is widely used against various diseases owing to the presence an array of medicinally important secondary metabolites. Its stem is bitter, stomachic, stimulates bile secretion, enriches the blood and cures diseases like diabetes, fever, flatulence, hypertension, jaundice, leucorrhoea, urinary disease and upper respiratory tract infection. It is neglected for tissue culture work because of deciduous nature of climbing shrub, facing problems for micropropagation. Hence, in vitro regeneration of complete plantlets was done through indirect organogenesis in Tylophora indica. Calli were produced from in vivo leaves of T. indica on MS medium supplemented with 6-Benzylaminopurine (BAP: 2.0 mg l(-1)) and Indole-3-butyric acid (IBA: 0.5 mg l(-1)). The multiple shoots (12.00 ± 1.50) emerged and elongated on MS medium fortified with Thidiazuron (TDZ: 0.1 mg l(-1)). They were rooted on half strength MS medium having IBA (0.5 mg l(-1)) (7.75 ± 0.25) after 20 days of sub-culturing followed by hardening and acclimatization. During indirect regeneration of plants, chances of somaclonal variations may arise. These variations should be identified to produce true to type plants. Plantlets raised through tissue culture were used to validate the clonal fidelity through Inter simple sequence repeat markers (ISSR). Clonal fidelity is a major consideration in commercial micropropagation using in vitro tissue culture methods. During the study, total 71 clear and distinct bands were produced using 6 primers. The banding pattern of each primer was uniform and comparable to mother plant and showed about 93% homology using un-weighted pair group method with arithmetic averaging (UPGMA). ISSR analysis confirmed the genetic stability of in vitro raised plants.

  17. High-Fidelity Single-Shot Readout for a Spin Qubit via an Enhanced Latching Mechanism

    NASA Astrophysics Data System (ADS)

    Harvey-Collard, Patrick; D'Anjou, Benjamin; Rudolph, Martin; Jacobson, N. Tobias; Dominguez, Jason; Ten Eyck, Gregory A.; Wendt, Joel R.; Pluym, Tammy; Lilly, Michael P.; Coish, William A.; Pioro-Ladrière, Michel; Carroll, Malcolm S.

    2018-04-01

    The readout of semiconductor spin qubits based on spin blockade is fast but suffers from a small charge signal. Previous work suggested large benefits from additional charge mapping processes; however, uncertainties remain about the underlying mechanisms and achievable fidelity. In this work, we study the single-shot fidelity and limiting mechanisms for two variations of an enhanced latching readout. We achieve average single-shot readout fidelities greater than 99.3% and 99.86% for the conventional and enhanced readout, respectively, the latter being the highest to date for spin blockade. The signal amplitude is enhanced to a full one-electron signal while preserving the readout speed. Furthermore, layout constraints are relaxed because the charge sensor signal is no longer dependent on being aligned with the conventional (2,0)-(1,1) charge dipole. Silicon donor-quantum-dot qubits are used for this study, for which the dipole insensitivity substantially relaxes donor placement requirements. One of the readout variations also benefits from a parametric lifetime enhancement by replacing the spin-relaxation process with a charge-metastable one. This provides opportunities to further increase the fidelity. The relaxation mechanisms in the different regimes are investigated. This work demonstrates a readout that is fast, has a one-electron signal, and results in higher fidelity. It further predicts that going beyond 99.9% fidelity in a few microseconds of measurement time is within reach.

  18. Advances in High-Fidelity Multi-Physics Simulation Techniques

    DTIC Science & Technology

    2008-01-01

    predictor - corrector method is used to advance the solution in time. 33 x (m) y (m ) 0 1 2 3.00001 0 1 2 3 4 5 40 x 50 Grid 3 Figure 17: Typical...Unclassified c . THIS PAGE Unclassified 17. LIMITATION OF ABSTRACT: SAR 18. NUMBER OF PAGES 60 Datta Gaitonde 19b. TELEPHONE...advanced parallel computing platforms. The motivation to develop high-fidelity algorithms derives from considerations in various areas of current

  19. ARC integration into the NEAMS Workbench

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stauff, N.; Gaughan, N.; Kim, T.

    2017-01-01

    One of the objectives of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Integration Product Line (IPL) is to facilitate the deployment of the high-fidelity codes developed within the program. The Workbench initiative was launched in FY-2017 by the IPL to facilitate the transition from conventional tools to high fidelity tools. The Workbench provides a common user interface for model creation, real-time validation, execution, output processing, and visualization for integrated codes.

  20. Implementing a strand of a scalable fault-tolerant quantum computing fabric.

    PubMed

    Chow, Jerry M; Gambetta, Jay M; Magesan, Easwar; Abraham, David W; Cross, Andrew W; Johnson, B R; Masluk, Nicholas A; Ryan, Colm A; Smolin, John A; Srinivasan, Srikanth J; Steffen, M

    2014-06-24

    With favourable error thresholds and requiring only nearest-neighbour interactions on a lattice, the surface code is an error-correcting code that has garnered considerable attention. At the heart of this code is the ability to perform a low-weight parity measurement of local code qubits. Here we demonstrate high-fidelity parity detection of two code qubits via measurement of a third syndrome qubit. With high-fidelity gates, we generate entanglement distributed across three superconducting qubits in a lattice where each code qubit is coupled to two bus resonators. Via high-fidelity measurement of the syndrome qubit, we deterministically entangle the code qubits in either an even or odd parity Bell state, conditioned on the syndrome qubit state. Finally, to fully characterize this parity readout, we develop a measurement tomography protocol. The lattice presented naturally extends to larger networks of qubits, outlining a path towards fault-tolerant quantum computing.

  1. General solution to inhomogeneous dephasing and smooth pulse dynamical decoupling

    NASA Astrophysics Data System (ADS)

    Zeng, Junkai; Deng, Xiu-Hao; Russo, Antonio; Barnes, Edwin

    2018-03-01

    In order to achieve the high-fidelity quantum control needed for a broad range of quantum information technologies, reducing the effects of noise and system inhomogeneities is an essential task. It is well known that a system can be decoupled from noise or made insensitive to inhomogeneous dephasing dynamically by using carefully designed pulse sequences based on square or delta-function waveforms such as Hahn spin echo or CPMG. However, such ideal pulses are often challenging to implement experimentally with high fidelity. Here, we uncover a new geometrical framework for visualizing all possible driving fields, which enables one to generate an unlimited number of smooth, experimentally feasible pulses that perform dynamical decoupling or dynamically corrected gates to arbitrarily high order. We demonstrate that this scheme can significantly enhance the fidelity of single-qubit operations in the presence of noise and when realistic limitations on pulse rise times and amplitudes are taken into account.

  2. Terascale High-Fidelity Simulations of Turbulent Combustion with Detailed Chemistry: Spray Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutland, Christopher J.

    2009-04-26

    The Terascale High-Fidelity Simulations of Turbulent Combustion (TSTC) project is a multi-university collaborative effort to develop a high-fidelity turbulent reacting flow simulation capability utilizing terascale, massively parallel computer technology. The main paradigm of the approach is direct numerical simulation (DNS) featuring the highest temporal and spatial accuracy, allowing quantitative observations of the fine-scale physics found in turbulent reacting flows as well as providing a useful tool for development of sub-models needed in device-level simulations. Under this component of the TSTC program the simulation code named S3D, developed and shared with coworkers at Sandia National Laboratories, has been enhanced with newmore » numerical algorithms and physical models to provide predictive capabilities for turbulent liquid fuel spray dynamics. Major accomplishments include improved fundamental understanding of mixing and auto-ignition in multi-phase turbulent reactant mixtures and turbulent fuel injection spray jets.« less

  3. Self-Reflection of Video-Recorded High-Fidelity Simulations and Development of Clinical Judgment.

    PubMed

    Bussard, Michelle E

    2016-09-01

    Nurse educators are increasingly using high-fidelity simulators to improve prelicensure nursing students' ability to develop clinical judgment. Traditionally, oral debriefing sessions have immediately followed the simulation scenarios as a method for students to connect theory to practice and therefore develop clinical judgment. Recently, video recording of the simulation scenarios is being incorporated. This qualitative, interpretive description study was conducted to identify whether self-reflection on video-recorded high-fidelity simulation (HFS) scenarios helped prelicensure nursing students to develop clinical judgment. Tanner's clinical judgment model was the framework for this study. Four themes emerged from this study: Confidence, Communication, Decision Making, and Change in Clinical Practice. This study indicated that self-reflection of video-recorded HFS scenarios is beneficial for prelicensure nursing students to develop clinical judgment. [J Nurs Educ. 2016;55(9):522-527.]. Copyright 2016, SLACK Incorporated.

  4. Evaluating intervention fidelity: an example from a high-intensity interval training study.

    PubMed

    Taylor, Kathryn L; Weston, Matthew; Batterham, Alan M

    2015-01-01

    Intervention fidelity refers to the degree to which an experimental manipulation has been implemented as intended, but simple, robust methods for quantifying fidelity have not been well documented. Therefore, we aim to illustrate a rigorous quantitative evaluation of intervention fidelity, using data collected during a high-intensity interval training intervention. Single-group measurement study. Seventeen adolescents (mean age ± standard deviation [SD] 14.0 ± 0.3 years) attended a 10-week high-intensity interval training intervention, comprising two exercise sessions per week. Sessions consisted of 4-7 45-s maximal effort repetitions, interspersed with 90-s rest. We collected heart rate data at 5-s intervals and recorded the peak heart rate for each repetition. The high-intensity exercise criterion was ≥ 90% of individual maximal heart rate. For each participant, we calculated the proportion of total exercise repetitions exceeding this threshold. A linear mixed model was applied to properly separate the variability in peak heart rate between- and within-subjects. Results are presented both as intention to treat (including missed sessions) and per protocol (only participants with 100% attendance; n=8). For intention to treat, the median (interquartile range) proportion of repetitions meeting the high-intensity criterion was 58% (42% to 68%). The mean peak heart rate was 85% of maximal, with a between-subject SD of 7.8 (95% confidence interval 5.4 to 11.3) percentage points and a within-subject SD of 15.1 (14.6 to 15.6) percentage points. For the per protocol analysis, the median proportion of high-intensity repetitions was 68% (47% to 86%). The mean peak heart rate was 91% of maximal, with between- and within-subject SDs of 3.1 (-1.3 to 4.6) and 3.4 (3.2 to 3.6) percentage points, respectively. Synthesising information on exercise session attendance and compliance (exercise intensity) quantifies the intervention dose and informs evaluations of treatment fidelity.

  5. Development of a measure of model fidelity for mental health Crisis Resolution Teams.

    PubMed

    Lloyd-Evans, Brynmor; Bond, Gary R; Ruud, Torleif; Ivanecka, Ada; Gray, Richard; Osborn, David; Nolan, Fiona; Henderson, Claire; Mason, Oliver; Goater, Nicky; Kelly, Kathleen; Ambler, Gareth; Morant, Nicola; Onyett, Steve; Lamb, Danielle; Fahmy, Sarah; Brown, Ellie; Paterson, Beth; Sweeney, Angela; Hindle, David; Fullarton, Kate; Frerichs, Johanna; Johnson, Sonia

    2016-12-01

    Crisis Resolution Teams (CRTs) provide short-term intensive home treatment to people experiencing mental health crisis. Trial evidence suggests CRTs can be effective at reducing hospital admissions and increasing satisfaction with acute care. When scaled up to national level however, CRT implementation and outcomes have been variable. We aimed to develop and test a fidelity scale to assess adherence to a model of best practice for CRTs, based on best available evidence. A concept mapping process was used to develop a CRT fidelity scale. Participants (n = 68) from a range of stakeholder groups prioritised and grouped statements (n = 72) about important components of the CRT model, generated from a literature review, national survey and qualitative interviews. These data were analysed using Ariadne software and the resultant cluster solution informed item selection for a CRT fidelity scale. Operational criteria and scoring anchor points were developed for each item. The CORE CRT fidelity scale was then piloted in 75 CRTs in the UK to assess the range of scores achieved and feasibility for use in a 1-day fidelity review process. Trained reviewers (n = 16) rated CRT service fidelity in a vignette exercise to test the scale's inter-rater reliability. There were high levels of agreement within and between stakeholder groups regarding the most important components of the CRT model. A 39-item measure of CRT model fidelity was developed. Piloting indicated that the scale was feasible for use to assess CRT model fidelity and had good face validity. The wide range of item scores and total scores across CRT services in the pilot demonstrate the measure can distinguish lower and higher fidelity services. Moderately good inter-rater reliability was found, with an estimated correlation between individual ratings of 0.65 (95% CI: 0.54 to 0.76). The CORE CRT Fidelity Scale has been developed through a rigorous and systematic process. Promising initial testing indicates its value in assessing adherence to a model of CRT best practice and to support service improvement monitoring and planning. Further research is required to establish its psychometric properties and international applicability.

  6. Children perceive speech onsets by ear and eye*

    PubMed Central

    JERGER, SUSAN; DAMIAN, MARKUS F.; TYE-MURRAY, NANCY; ABDI, HERVÉ

    2016-01-01

    Adults use vision to perceive low-fidelity speech; yet how children acquire this ability is not well understood. The literature indicates that children show reduced sensitivity to visual speech from kindergarten to adolescence. We hypothesized that this pattern reflects the effects of complex tasks and a growth period with harder-to-utilize cognitive resources, not lack of sensitivity. We investigated sensitivity to visual speech in children via the phonological priming produced by low-fidelity (non-intact onset) auditory speech presented audiovisually (see dynamic face articulate consonant/rhyme b/ag; hear non-intact onset/rhyme: −b/ag) vs. auditorily (see still face; hear exactly same auditory input). Audiovisual speech produced greater priming from four to fourteen years, indicating that visual speech filled in the non-intact auditory onsets. The influence of visual speech depended uniquely on phonology and speechreading. Children – like adults – perceive speech onsets multimodally. Findings are critical for incorporating visual speech into developmental theories of speech perception. PMID:26752548

  7. Evaluating the Implementation Fidelity of Technology Immersion and Its Relationship with Student Achievement

    ERIC Educational Resources Information Center

    Shapley, Kelly S.; Sheehan, Daniel; Maloney, Catherine; Caranikas-Walker, Fanny

    2010-01-01

    In a pilot study of the Technology Immersion model, high-need middle schools were "immersed" in technology by providing a laptop for each student and teacher, wireless Internet access, curricular and assessment resources, professional development, and technical and pedagogical support. This article examines the fidelity of model…

  8. Attenuation of foot-and-mouth disease virus by engineered viral polymerase fidelity

    USDA-ARS?s Scientific Manuscript database

    The foot-and-mouth disease virus (FMDV) RNA dependent RNA polymerase (RdRp or 3Dpol) catalyzes viral RNA synthesis. The 3Dpol is a low fidelity enzyme incapable of proofreading which results in a high mutation frequencies that allow the virus to rapidly adapt to different environments. In this study...

  9. Nursing Simulation: A Review of the Past 40 Years

    ERIC Educational Resources Information Center

    Nehring, Wendy M.; Lashley, Felissa R.

    2009-01-01

    Simulation, in its many forms, has been a part of nursing education and practice for many years. The use of games, computer-assisted instruction, standardized patients, virtual reality, and low-fidelity to high-fidelity mannequins have appeared in the past 40 years, whereas anatomical models, partial task trainers, and role playing were used…

  10. Administrator Strategies that Support High Fidelity Implementation of the Pyramid Model for Promoting Social-Emotional Competence & Addressing Challenging Behavior

    ERIC Educational Resources Information Center

    Mincic, Melissa; Smith, Barbara J.; Strain, Phil

    2009-01-01

    Implementing the Pyramid Model with fidelity and achieving positive outcomes for children and their families requires that administrators understand their roles in the implementation process. Every administrative decision impacts program quality and sustainability. This Policy Brief underscores the importance of facilitative administrative…

  11. A Randomized Controlled Study of Manikin Simulator Fidelity on Neonatal Resuscitation Program Learning Outcomes

    ERIC Educational Resources Information Center

    Curran, Vernon; Fleet, Lisa; White, Susan; Bessell, Clare; Deshpandey, Akhil; Drover, Anne; Hayward, Mark; Valcour, James

    2015-01-01

    The neonatal resuscitation program (NRP) has been developed to educate physicians and other health care providers about newborn resuscitation and has been shown to improve neonatal resuscitation skills. Simulation-based training is recommended as an effective modality for instructing neonatal resuscitation and both low and high-fidelity manikin…

  12. Fidelity and over-wintering of sea turtles.

    PubMed

    Broderick, Annette C; Coyne, Michael S; Fuller, Wayne J; Glen, Fiona; Godley, Brendan J

    2007-06-22

    While fidelity to breeding sites is well demonstrated in marine turtles, emerging knowledge of migratory routes and key foraging sites is of limited conservation value unless levels of fidelity can be established. We tracked green (Chelonia mydas, n=10) and loggerhead (Caretta caretta, n=10) turtles during their post-nesting migration from the island of Cyprus to their foraging grounds. After intervals of 2-5 years, five of these females were recaptured at the nesting beach and tracked for a second migration. All five used highly similar migratory routes to return to the same foraging and over-wintering areas. None of the females visited other foraging habitats over the study period (units lasted on average 305 days; maximum, 1356 days), moving only to deeper waters during the winter months where they demonstrated extremely long resting dives of up to 10.2h (the longest breath-holding dive recorded for a marine vertebrate). High levels of fidelity and the relatively discrete nature of the home ranges demonstrate that protection of key migratory pathways, foraging and over-wintering sites can serve as an important tool for the future conservation of marine turtles.

  13. Optimization of a solid-state electron spin qubit using Gate Set Tomography

    DOE PAGES

    Dehollain, Juan P.; Muhonen, Juha T.; Blume-Kohout, Robin J.; ...

    2016-10-13

    Here, state of the art qubit systems are reaching the gate fidelities required for scalable quantum computation architectures. Further improvements in the fidelity of quantum gates demands characterization and benchmarking protocols that are efficient, reliable and extremely accurate. Ideally, a benchmarking protocol should also provide information on how to rectify residual errors. Gate Set Tomography (GST) is one such protocol designed to give detailed characterization of as-built qubits. We implemented GST on a high-fidelity electron-spin qubit confined by a single 31P atom in 28Si. The results reveal systematic errors that a randomized benchmarking analysis could measure but not identify, whereasmore » GST indicated the need for improved calibration of the length of the control pulses. After introducing this modification, we measured a new benchmark average gate fidelity of 99.942(8)%, an improvement on the previous value of 99.90(2)%. Furthermore, GST revealed high levels of non-Markovian noise in the system, which will need to be understood and addressed when the qubit is used within a fault-tolerant quantum computation scheme.« less

  14. A study on model fidelity for model predictive control-based obstacle avoidance in high-speed autonomous ground vehicles

    NASA Astrophysics Data System (ADS)

    Liu, Jiechao; Jayakumar, Paramsothy; Stein, Jeffrey L.; Ersal, Tulga

    2016-11-01

    This paper investigates the level of model fidelity needed in order for a model predictive control (MPC)-based obstacle avoidance algorithm to be able to safely and quickly avoid obstacles even when the vehicle is close to its dynamic limits. The context of this work is large autonomous ground vehicles that manoeuvre at high speed within unknown, unstructured, flat environments and have significant vehicle dynamics-related constraints. Five different representations of vehicle dynamics models are considered: four variations of the two degrees-of-freedom (DoF) representation as lower fidelity models and a fourteen DoF representation with combined-slip Magic Formula tyre model as a higher fidelity model. It is concluded that the two DoF representation that accounts for tyre nonlinearities and longitudinal load transfer is necessary for the MPC-based obstacle avoidance algorithm in order to operate the vehicle at its limits within an environment that includes large obstacles. For less challenging environments, however, the two DoF representation with linear tyre model and constant axle loads is sufficient.

  15. Broken symmetry in a two-qubit quantum control landscape

    NASA Astrophysics Data System (ADS)

    Bukov, Marin; Day, Alexandre G. R.; Weinberg, Phillip; Polkovnikov, Anatoli; Mehta, Pankaj; Sels, Dries

    2018-05-01

    We analyze the physics of optimal protocols to prepare a target state with high fidelity in a symmetrically coupled two-qubit system. By varying the protocol duration, we find a discontinuous phase transition, which is characterized by a spontaneous breaking of a Z2 symmetry in the functional form of the optimal protocol, and occurs below the quantum speed limit. We study in detail this phase and demonstrate that even though high-fidelity protocols come degenerate with respect to their fidelity, they lead to final states of different entanglement entropy shared between the qubits. Consequently, while globally both optimal protocols are equally far away from the target state, one is locally closer than the other. An approximate variational mean-field theory which captures the physics of the different phases is developed.

  16. Experimental magic state distillation for fault-tolerant quantum computing.

    PubMed

    Souza, Alexandre M; Zhang, Jingfu; Ryan, Colm A; Laflamme, Raymond

    2011-01-25

    Any physical quantum device for quantum information processing (QIP) is subject to errors in implementation. In order to be reliable and efficient, quantum computers will need error-correcting or error-avoiding methods. Fault-tolerance achieved through quantum error correction will be an integral part of quantum computers. Of the many methods that have been discovered to implement it, a highly successful approach has been to use transversal gates and specific initial states. A critical element for its implementation is the availability of high-fidelity initial states, such as |0〉 and the 'magic state'. Here, we report an experiment, performed in a nuclear magnetic resonance (NMR) quantum processor, showing sufficient quantum control to improve the fidelity of imperfect initial magic states by distilling five of them into one with higher fidelity.

  17. High-Fidelity Preservation of Quantum Information During Trapped-Ion Transport

    NASA Astrophysics Data System (ADS)

    Kaufmann, Peter; Gloger, Timm F.; Kaufmann, Delia; Johanning, Michael; Wunderlich, Christof

    2018-01-01

    A promising scheme for building scalable quantum simulators and computers is the synthesis of a scalable system using interconnected subsystems. A prerequisite for this approach is the ability to faithfully transfer quantum information between subsystems. With trapped atomic ions, this can be realized by transporting ions with quantum information encoded into their internal states. Here, we measure with high precision the fidelity of quantum information encoded into hyperfine states of a Yb171 + ion during ion transport in a microstructured Paul trap. Ramsey spectroscopy of the ion's internal state is interleaved with up to 4000 transport operations over a distance of 280 μ m each taking 12.8 μ s . We obtain a state fidelity of 99.9994 (-7+6) % per ion transport.

  18. Optimal control of fast and high-fidelity quantum state transfer in spin-1/2 chains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xiong-Peng; Shao, Bin, E-mail: sbin610@bit.edu.cn; Hu, Shuai

    Spin chains are promising candidates for quantum communication and computation. Using quantum optimal control (OC) theory based on the Krotov method, we present a protocol to perform quantum state transfer with fast and high fidelity by only manipulating the boundary spins in a quantum spin-1/2 chain. The achieved speed is about one order of magnitude faster than that is possible in the Lyapunov control case for comparable fidelities. Additionally, it has a fundamental limit for OC beyond which optimization is not possible. The controls are exerted only on the couplings between the boundary spins and their neighbors, so that themore » scheme has good scalability. We also demonstrate that the resulting OC scheme is robust against disorder in the chain.« less

  19. High-fidelity phase and amplitude control of phase-only computer generated holograms using conjugate gradient minimisation.

    PubMed

    Bowman, D; Harte, T L; Chardonnet, V; De Groot, C; Denny, S J; Le Goc, G; Anderson, M; Ireland, P; Cassettari, D; Bruce, G D

    2017-05-15

    We demonstrate simultaneous control of both the phase and amplitude of light using a conjugate gradient minimisation-based hologram calculation technique and a single phase-only spatial light modulator (SLM). A cost function, which incorporates the inner product of the light field with a chosen target field within a defined measure region, is efficiently minimised to create high fidelity patterns in the Fourier plane of the SLM. A fidelity of F = 0.999997 is achieved for a pattern resembling an LG10 mode with a calculated light-usage efficiency of 41.5%. Possible applications of our method in optical trapping and ultracold atoms are presented and we show uncorrected experimental realisation of our patterns with F = 0.97 and 7.8% light efficiency.

  20. Generation of a high-fidelity antibody against nerve growth factor using library scanning mutagenesis and validation with structures of the initial and optimized Fab-antigen complexes

    PubMed Central

    La Porte, Sherry L; Eigenbrot, Charles; Ultsch, Mark; Ho, Wei-Hsien; Foletti, Davide; Forgie, Alison; Lindquist, Kevin C; Shelton, David L; Pons, Jaume

    2014-01-01

    Nerve growth factor (NGF) is indispensable during normal embryonic development and critical for the amplification of pain signals in adults. Intervention in NGF signaling holds promise for the alleviation of pain resulting from human diseases such as osteoarthritis, cancer and chronic lower back disorders. We developed a fast, high-fidelity method to convert a hybridoma-derived NGF-targeted mouse antibody into a clinical candidate. This method, termed Library Scanning Mutagenesis (LSM), resulted in the ultra-high affinity antibody tanezumab, a first-in-class anti-hyperalgesic specific for an NGF epitope. Functional and structural comparisons between tanezumab and the mouse 911 precursor antibody using neurotrophin-specific cell survival assays and X-ray crystal structures of both Fab-antigen complexes illustrated high fidelity retention of the NGF epitope. These results suggest the potential for wide applicability of the LSM method for optimization of well-characterized antibodies during humanization. PMID:24830649

  1. Developing Capture Mechanisms and High-Fidelity Dynamic Models for the MXER Tether System

    NASA Technical Reports Server (NTRS)

    Canfield, Steven L.

    2007-01-01

    A team consisting of collaborators from Tennessee Technological University (TTU), Marshall Space Flight Center, BD Systems, and the University of Delaware (herein called the TTU team) conducted specific research and development activities in MXER tether systems during the base period of May 15, 2004 through September 30, 2006 under contract number NNM04AB13C. The team addressed two primary topics related to the MXER tether system: 1) Development of validated high-fidelity dynamic models of an elastic rotating tether and 2) development of feasible mechanisms to enable reliable rendezvous and capture. This contractor report will describe in detail the activities that were performed during the base period of this cycle-2 MXER tether activity and will summarize the results of this funded activity. The primary deliverables of this project were the quad trap, a robust capture mechanism proposed, developed, tested, and demonstrated with a high degree of feasibility and the detailed development of a validated high-fidelity elastic tether dynamic model provided through multiple formulations.

  2. A high-fidelity satellite ephemeris program for Earth satellites in eccentric orbits

    NASA Technical Reports Server (NTRS)

    Simmons, David R.

    1990-01-01

    A program for mission planning called the Analytic Satellite Ephemeris Program (ASEP), produces projected data for orbits that remain fairly close to the Earth. ASEP does not take into account lunar and solar perturbations. These perturbations are accounted for in another program called GRAVE, which incorporates more flexible means of input for initial data, provides additional kinds of output information, and makes use of structural programming techniques to make the program more understandable and reliable. GRAVE was revised, and a new program called ORBIT was developed. It is divided into three major phases: initialization, integration, and output. Results of the program development are presented.

  3. Creating Fidelitious Climate Data Records from Meteosat First Generation Observations

    NASA Astrophysics Data System (ADS)

    Quast, Ralf; Govaerts, Yves; Ruthrich, Frank; Giering, Ralf; Roebeling, Rob

    2016-08-01

    A novel method for reconstructing the spectral response function of the Meteosat visible (VIS) channels is presented and applied to the Meteosat-10 Spinning Enhanced Visible and Infrared Imager (SEVIRI) high-resolution visible (HRV) channel as the first real-world benchmark. The method incorporates advanced radiative transfer modelling and inverse modelling techniques. Once established, EUMETSAT will use the reconstructed spectral response and uncertainty information to increase the calibration accuracy of Meteosat First Generation VIS observations, which will provide the basis for the Fidelity and Uncertainty in Climate data records from Earth Observations (FIDUCEO) Horizon 2020 project to produce new fundamental (reflectance) and thematic (albedo and aerosol) climate data records.

  4. Three-color Sagnac source of polarization-entangled photon pairs.

    PubMed

    Hentschel, Michael; Hübel, Hannes; Poppe, Andreas; Zeilinger, Anton

    2009-12-07

    We demonstrate a compact and stable source of polarization-entangled pairs of photons, one at 810 nm wavelength for high detection efficiency and the other at 1550 nm for long-distance fiber communication networks. Due to a novel Sagnac-based design of the interferometer no active stabilization is needed. Using only one 30 mm ppKTP bulk crystal the source produces photons with a spectral brightness of 1.13 x 10(6) pairs/s/mW/THz with an entanglement fidelity of 98.2%. Both photons are single-mode fiber coupled and ready to be used in quantum key distribution (QKD) or transmission of photonic quantum states over large distances.

  5. Generation and control of Greenberger-Horne-Zeilinger entanglement in superconducting circuits.

    PubMed

    Wei, L F; Liu, Yu-xi; Nori, Franco

    2006-06-23

    Going beyond the entanglement of microscopic objects (such as photons, spins, and ions), here we propose an efficient approach to produce and control the quantum entanglement of three macroscopic coupled superconducting qubits. By conditionally rotating, one by one, selected Josephson-charge qubits, we show that their Greenberger-Horne-Zeilinger (GHZ) entangled states can be deterministically generated. The existence of GHZ correlations between these qubits could be experimentally demonstrated by effective single-qubit operations followed by high-fidelity single-shot readouts. The possibility of using the prepared GHZ correlations to test the macroscopic conflict between the noncommutativity of quantum mechanics and the commutativity of classical physics is also discussed.

  6. Hi-fidelity multi-scale local processing for visually optimized far-infrared Herschel images

    NASA Astrophysics Data System (ADS)

    Li Causi, G.; Schisano, E.; Liu, S. J.; Molinari, S.; Di Giorgio, A.

    2016-07-01

    In the context of the "Hi-Gal" multi-band full-plane mapping program for the Galactic Plane, as imaged by the Herschel far-infrared satellite, we have developed a semi-automatic tool which produces high definition, high quality color maps optimized for visual perception of extended features, like bubbles and filaments, against the high background variations. We project the map tiles of three selected bands onto a 3-channel panorama, which spans the central 130 degrees of galactic longitude times 2.8 degrees of galactic latitude, at the pixel scale of 3.2", in cartesian galactic coordinates. Then we process this image piecewise, applying a custom multi-scale local stretching algorithm, enforced by a local multi-scale color balance. Finally, we apply an edge-preserving contrast enhancement to perform an artifact-free details sharpening. Thanks to this tool, we have thus produced a stunning giga-pixel color image of the far-infrared Galactic Plane that we made publicly available with the recent release of the Hi-Gal mosaics and compact source catalog.

  7. Influence of World and Gravity Model Selection on Surface Interacting Vehicle Simulations

    NASA Technical Reports Server (NTRS)

    Madden, Michael M.

    2007-01-01

    A vehicle simulation is surface-interacting if the state of the vehicle (position, velocity, and acceleration) relative to the surface is important. Surface-interacting simulations perform ascent, entry, descent, landing, surface travel, or atmospheric flight. Modeling of gravity is an influential environmental factor for surface-interacting simulations. Gravity is the free-fall acceleration observed from a world-fixed frame that rotates with the world. Thus, gravity is the sum of gravitation and the centrifugal acceleration due to the world s rotation. In surface-interacting simulations, the fidelity of gravity at heights above the surface is more significant than gravity fidelity at locations in inertial space. A surface-interacting simulation cannot treat the gravity model separately from the world model, which simulates the motion and shape of the world. The world model's simulation of the world's rotation, or lack thereof, produces the centrifugal acceleration component of gravity. The world model s reproduction of the world's shape will produce different positions relative to the world center for a given height above the surface. These differences produce variations in the gravitation component of gravity. This paper examines the actual performance of world and gravity/gravitation pairs in a simulation using the Earth.

  8. Biosensor Architectures for High-Fidelity Reporting of Cellular Signaling

    PubMed Central

    Dushek, Omer; Lellouch, Annemarie C.; Vaux, David J.; Shahrezaei, Vahid

    2014-01-01

    Understanding mechanisms of information processing in cellular signaling networks requires quantitative measurements of protein activities in living cells. Biosensors are molecular probes that have been developed to directly track the activity of specific signaling proteins and their use is revolutionizing our understanding of signal transduction. The use of biosensors relies on the assumption that their activity is linearly proportional to the activity of the signaling protein they have been engineered to track. We use mechanistic mathematical models of common biosensor architectures (single-chain FRET-based biosensors), which include both intramolecular and intermolecular reactions, to study the validity of the linearity assumption. As a result of the classic mechanism of zero-order ultrasensitivity, we find that biosensor activity can be highly nonlinear so that small changes in signaling protein activity can give rise to large changes in biosensor activity and vice versa. This nonlinearity is abolished in architectures that favor the formation of biosensor oligomers, but oligomeric biosensors produce complicated FRET states. Based on this finding, we show that high-fidelity reporting is possible when a single-chain intermolecular biosensor is used that cannot undergo intramolecular reactions and is restricted to forming dimers. We provide phase diagrams that compare various trade-offs, including observer effects, which further highlight the utility of biosensor architectures that favor intermolecular over intramolecular binding. We discuss challenges in calibrating and constructing biosensors and highlight the utility of mathematical models in designing novel probes for cellular signaling. PMID:25099816

  9. Compressed Sensing Quantum Process Tomography for Superconducting Quantum Gates

    NASA Astrophysics Data System (ADS)

    Rodionov, Andrey

    An important challenge in quantum information science and quantum computing is the experimental realization of high-fidelity quantum operations on multi-qubit systems. Quantum process tomography (QPT) is a procedure devised to fully characterize a quantum operation. We first present the results of the estimation of the process matrix for superconducting multi-qubit quantum gates using the full data set employing various methods: linear inversion, maximum likelihood, and least-squares. To alleviate the problem of exponential resource scaling needed to characterize a multi-qubit system, we next investigate a compressed sensing (CS) method for QPT of two-qubit and three-qubit quantum gates. Using experimental data for two-qubit controlled-Z gates, taken with both Xmon and superconducting phase qubits, we obtain estimates for the process matrices with reasonably high fidelities compared to full QPT, despite using significantly reduced sets of initial states and measurement configurations. We show that the CS method still works when the amount of data is so small that the standard QPT would have an underdetermined system of equations. We also apply the CS method to the analysis of the three-qubit Toffoli gate with simulated noise, and similarly show that the method works well for a substantially reduced set of data. For the CS calculations we use two different bases in which the process matrix is approximately sparse (the Pauli-error basis and the singular value decomposition basis), and show that the resulting estimates of the process matrices match with reasonably high fidelity. For both two-qubit and three-qubit gates, we characterize the quantum process by its process matrix and average state fidelity, as well as by the corresponding standard deviation defined via the variation of the state fidelity for different initial states. We calculate the standard deviation of the average state fidelity both analytically and numerically, using a Monte Carlo method. Overall, we show that CS QPT offers a significant reduction in the needed amount of experimental data for two-qubit and three-qubit quantum gates.

  10. Optical nano-woodpiles: large-area metallic photonic crystals and metamaterials

    PubMed Central

    Ibbotson, Lindsey A.; Demetriadou, Angela; Croxall, Stephen; Hess, Ortwin; Baumberg, Jeremy J.

    2015-01-01

    Metallic woodpile photonic crystals and metamaterials operating across the visible spectrum are extremely difficult to construct over large areas, because of the intricate three-dimensional nanostructures and sub-50 nm features demanded. Previous routes use electron-beam lithography or direct laser writing but widespread application is restricted by their expense and low throughput. Scalable approaches including soft lithography, colloidal self-assembly, and interference holography, produce structures limited in feature size, material durability, or geometry. By multiply stacking gold nanowire flexible gratings, we demonstrate a scalable high-fidelity approach for fabricating flexible metallic woodpile photonic crystals, with features down to 10 nm produced in bulk and at low cost. Control of stacking sequence, asymmetry, and orientation elicits great control, with visible-wavelength band-gap reflections exceeding 60%, and with strong induced chirality. Such flexible and stretchable architectures can produce metamaterials with refractive index near zero, and are easily tuned across the IR and visible ranges. PMID:25660667

  11. Fidelity by design: Yoctoreactor and binder trap enrichment for small-molecule DNA-encoded libraries and drug discovery.

    PubMed

    Blakskjaer, Peter; Heitner, Tara; Hansen, Nils Jakob Vest

    2015-06-01

    DNA-encoded small-molecule library (DEL) technology allows vast drug-like small molecule libraries to be efficiently synthesized in a combinatorial fashion and screened in a single tube method for binding, with an assay readout empowered by advances in next generation sequencing technology. This approach has increasingly been applied as a viable technology for the identification of small-molecule modulators to protein targets and as precursors to drugs in the past decade. Several strategies for producing and for screening DELs have been devised by both academic and industrial institutions. This review highlights some of the most significant and recent strategies along with important results. A special focus on the production of high fidelity DEL technologies with the ability to eliminate screening noise and false positives is included: using a DNA junction called the Yoctoreactor, building blocks (BBs) are spatially confined at the center of the junction facilitating both the chemical reaction between BBs and encoding of the synthetic route. A screening method, known as binder trap enrichment, permits DELs to be screened robustly in a homogeneous manner delivering clean data sets and potent hits for even the most challenging targets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Design optimization using adjoint of Long-time LES for the trailing edge of a transonic turbine vane

    NASA Astrophysics Data System (ADS)

    Talnikar, Chaitanya; Wang, Qiqi

    2017-11-01

    Adjoint-based design optimization methods have been applied to low-fidelity simulation methods like Reynolds Averaged Navier-Stokes (RANS) and are useful for designing fluid machinery components. But to reliably capture the complex flow phenomena involved in turbomachinery, high fidelity simulations like large eddy simulation (LES) are required. Unfortunately due to the chaotic dynamics of turbulence, the unsteady adjoint method for LES diverges and produces incorrect gradients. Using a viscosity stabilized unsteady adjoint method developed for LES, the gradient can be obtained with reasonable accuracy. In this paper, design of the trailing edge of a gas turbine inlet guide vane is performed with the objective to reduce stagnation pressure loss and heat transfer over the surface of the vane. Slight changes in the shape of trailing edge can significantly impact these quantities by altering the boundary layer development process and separation points. The trailing edge is parameterized using a linear combination of 5 convex designs. Bayesian optimization is used as a global optimizer with the objective function evaluated from the LES and gradients obtained using the viscosity adjoint method. Results from the optimization, performed on the supercomputer Mira, are presented.

  13. Left Ventricular, Systemic Arterial and Baroreflex Responses to Ketamine and TEE in Chronically Instrumented Monkeys

    DTIC Science & Technology

    2001-12-01

    instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to...isoflurane in 100% oxy- gen) prior to insertion of the high -fidelity pressure micromanome- ters during cardiac fluoroscopy. Once the micromanometer trans...and allowed to fully recover from the isoflurane seda- tion for a period of 60 min, during which blood pressure and aortic flow were monitored to ensure

  14. Solar Sail Spaceflight Simulation

    NASA Technical Reports Server (NTRS)

    Lisano, Michael; Evans, James; Ellis, Jordan; Schimmels, John; Roberts, Timothy; Rios-Reyes, Leonel; Scheeres, Daniel; Bladt, Jeff; Lawrence, Dale; Piggott, Scott

    2007-01-01

    The Solar Sail Spaceflight Simulation Software (S5) toolkit provides solar-sail designers with an integrated environment for designing optimal solar-sail trajectories, and then studying the attitude dynamics/control, navigation, and trajectory control/correction of sails during realistic mission simulations. Unique features include a high-fidelity solar radiation pressure model suitable for arbitrarily-shaped solar sails, a solar-sail trajectory optimizer, capability to develop solar-sail navigation filter simulations, solar-sail attitude control models, and solar-sail high-fidelity force models.

  15. Interprofessional education in pharmacology using high-fidelity simulation.

    PubMed

    Meyer, Brittney A; Seefeldt, Teresa M; Ngorsuraches, Surachat; Hendrickx, Lori D; Lubeck, Paula M; Farver, Debra K; Heins, Jodi R

    2017-11-01

    This study examined the feasibility of an interprofessional high-fidelity pharmacology simulation and its impact on pharmacy and nursing students' perceptions of interprofessionalism and pharmacology knowledge. Pharmacy and nursing students participated in a pharmacology simulation using a high-fidelity patient simulator. Faculty-facilitated debriefing included discussion of the case and collaboration. To determine the impact of the activity on students' perceptions of interprofessionalism and their ability to apply pharmacology knowledge, surveys were administered to students before and after the simulation. Attitudes Toward Health Care Teams scale (ATHCT) scores improved from 4.55 to 4.72 on a scale of 1-6 (p = 0.005). Almost all (over 90%) of the students stated their pharmacology knowledge and their ability to apply that knowledge improved following the simulation. A simulation in pharmacology is feasible and favorably affected students' interprofessionalism and pharmacology knowledge perceptions. Pharmacology is a core science course required by multiple health professions in early program curricula, making it favorable for incorporation of interprofessional learning experiences. However, reports of high-fidelity interprofessional simulation in pharmacology courses are limited. This manuscript contributes to the literature in the field of interprofessional education by demonstrating that an interprofessional simulation in pharmacology is feasible and can favorably affect students' perceptions of interprofessionalism. This manuscript provides an example of a pharmacology interprofessional simulation that faculty in other programs can use to build similar educational activities. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. High-Fidelity Simulation: Preparing Dental Hygiene Students for Managing Medical Emergencies.

    PubMed

    Bilich, Lisa A; Jackson, Sarah C; Bray, Brenda S; Willson, Megan N

    2015-09-01

    Medical emergencies can occur at any time in the dental office, so being prepared to properly manage the situation can be the difference between life and death. The entire dental team must be properly trained regarding all aspects of emergency management in the dental clinic. The aim of this study was to evaluate a new educational approach using a high-fidelity simulator to prepare dental hygiene students for medical emergencies. This study utilized high-fidelity simulation (HFS) to evaluate the abilities of junior dental hygiene students at Eastern Washington University to handle a medical emergency in the dental hygiene clinic. Students were given a medical emergency scenario requiring them to assess the emergency and implement life-saving protocols in a simulated "real-life" situation using a high-fidelity manikin. Retrospective data were collected for four years from the classes of 2010 through 2013 (N=114). The results indicated that learning with simulation was effective in helping the students identify the medical emergency in a timely manner, implement emergency procedures correctly, locate and correctly utilize contents of the emergency kit, administer appropriate intervention/treatment for a specific patient, and provide the patient with appropriate follow-up instructions. For dental hygiene programs seeking to enhance their curricula in the area of medical emergencies, this study suggests that HFS is an effective tool to prepare students to appropriately handle medical emergencies. Faculty calibration is essential to standardize simulation.

  17. Efficient multiparticle entanglement via asymmetric Rydberg blockade.

    PubMed

    Saffman, M; Mølmer, K

    2009-06-19

    We present an efficient method for producing N particle entangled states using Rydberg blockade interactions. Optical excitation of Rydberg states that interact weakly, yet have a strong coupling to a second control state is used to achieve state dependent qubit rotations in small ensembles. On the basis of quantitative calculations, we predict that an entangled quantum superposition state of eight atoms can be produced with a fidelity of 84% in cold Rb atoms.

  18. Virtual Reality Compared with Bench-Top Simulation in the Acquisition of Arthroscopic Skill: A Randomized Controlled Trial.

    PubMed

    Banaszek, Daniel; You, Daniel; Chang, Justues; Pickell, Michael; Hesse, Daniel; Hopman, Wilma M; Borschneck, Daniel; Bardana, Davide

    2017-04-05

    Work-hour restrictions as set forth by the Accreditation Council for Graduate Medical Education (ACGME) and other governing bodies have forced training programs to seek out new learning tools to accelerate acquisition of both medical skills and knowledge. As a result, competency-based training has become an important part of residency training. The purpose of this study was to directly compare arthroscopic skill acquisition in both high-fidelity and low-fidelity simulator models and to assess skill transfer from either modality to a cadaveric specimen, simulating intraoperative conditions. Forty surgical novices (pre-clerkship-level medical students) voluntarily participated in this trial. Baseline demographic data, as well as data on arthroscopic knowledge and skill, were collected prior to training. Subjects were randomized to 5-week independent training sessions on a high-fidelity virtual reality arthroscopic simulator or on a bench-top arthroscopic setup, or to an untrained control group. Post-training, subjects were asked to perform a diagnostic arthroscopy on both simulators and in a simulated intraoperative environment on a cadaveric knee. A more difficult surprise task was also incorporated to evaluate skill transfer. Subjects were evaluated using the Global Rating Scale (GRS), the 14-point arthroscopic checklist, and a timer to determine procedural efficiency (time per task). Secondary outcomes focused on objective measures of virtual reality simulator motion analysis. Trainees on both simulators demonstrated a significant improvement (p < 0.05) in arthroscopic skills compared with baseline scores and untrained controls, both in and ex vivo. The virtual reality simulation group consistently outperformed the bench-top model group in the diagnostic arthroscopy crossover tests and in the simulated cadaveric setup. Furthermore, the virtual reality group demonstrated superior skill transfer in the surprise skill transfer task. Both high-fidelity and low-fidelity simulation trainings were effective in arthroscopic skill acquisition. High-fidelity virtual reality simulation was superior to bench-top simulation in the acquisition of arthroscopic skills, both in the laboratory and in vivo. Further clinical investigation is needed to interpret the importance of these results.

  19. Implementing the LifeSkills Training drug prevention program: factors related to implementation fidelity.

    PubMed

    Mihalic, Sharon F; Fagan, Abigail A; Argamaso, Susanne

    2008-01-18

    Widespread replication of effective prevention programs is unlikely to affect the incidence of adolescent delinquency, violent crime, and substance use until the quality of implementation of these programs by community-based organizations can be assured. This paper presents the results of a process evaluation employing qualitative and quantitative methods to assess the extent to which 432 schools in 105 sites implemented the LifeSkills Training (LST) drug prevention program with fidelity. Regression analysis was used to examine factors influencing four dimensions of fidelity: adherence, dosage, quality of delivery, and student responsiveness. Although most sites faced common barriers, such as finding room in the school schedule for the program, gaining full support from key participants (i.e., site coordinators, principals, and LST teachers), ensuring teacher participation in training workshops, and classroom management difficulties, most schools involved in the project implemented LST with very high levels of fidelity. Across sites, 86% of program objectives and activities required in the three-year curriculum were delivered to students. Moreover, teachers were observed using all four recommended teaching practices, and 71% of instructors taught all the required LST lessons. Multivariate analyses found that highly rated LST program characteristics and better student behavior were significantly related to a greater proportion of material taught by teachers (adherence). Instructors who rated the LST program characteristics as ideal were more likely to teach all lessons (dosage). Student behavior and use of interactive teaching techniques (quality of delivery) were positively related. No variables were related to student participation (student responsiveness). Although difficult, high implementation fidelity by community-based organizations can be achieved. This study suggests some important factors that organizations should consider to ensure fidelity, such as selecting programs with features that minimize complexity while maximizing flexibility. Time constraints in the classroom should be considered when choosing a program. Student behavior also influences program delivery, so schools should train teachers in the use of classroom management skills. This project involved comprehensive program monitoring and technical assistance that likely facilitated the identification and resolution of problems and contributed to the overall high quality of implementation. Schools should recognize the importance of training and technical assistance to ensure quality program delivery.

  20. Fidelity and persistence of Ring-billed (Larus delawarensis) and Herring (Larus argentatus) gulls to wintering sites

    USGS Publications Warehouse

    Clark, Daniel E.; Koenen, Kiana K. G.; Whitney, Jillian J.; MacKenzie, Kenneth G.; DeStefano, Stephen

    2016-01-01

    While the breeding ecology of gulls (Laridae) has been well studied, their movements and spatial organization during the non-breeding season is poorly understood. The seasonal movements, winter-site fidelity, and site persistence of Ring-billed (Larus delawarensis) and Herring (L. argentatus) gulls to wintering areas were studied from 2008–2012. Satellite transmitters were deployed on Ring-billed Gulls (n = 21) and Herring Gulls (n = 14). Ten Ring-billed and six Herring gulls were tracked over multiple winters and > 300 wing-tagged Ring-billed Gulls were followed to determine winter-site fidelity and persistence. Home range overlap for individuals between years ranged between 0–1.0 (95% minimum convex polygon) and 0.31–0.79 (kernel utilization distributions). Ringbilled and Herring gulls remained at local wintering sites during the non-breeding season from 20–167 days and 74–161 days, respectively. The probability of a tagged Ring-billed Gull returning to the same site in subsequent winters was high; conversely, there was a low probability of a Ring-billed Gull returning to a different site. Ring-billed and Herring gulls exhibited high winter-site fidelity, but exhibited variable site persistence during the winter season, leading to a high probability of encountering the same individuals in subsequent winters.

  1. Thermal Protection System Mass Estimating Relationships for Blunt-Body, Earth Entry Spacecraft

    NASA Technical Reports Server (NTRS)

    Sepka, Steven A.; Samareh, Jamshid A.

    2015-01-01

    System analysis and design of any entry system must balance the level fidelity for each discipline against the project timeline. One way to inject high fidelity analysis earlier in the design effort is to develop surrogate models for the high-fidelity disciplines. Surrogate models for the Thermal Protection System (TPS) are formulated as Mass Estimating Relationships (MERs). The TPS MERs are presented that predict the amount of TPS necessary for safe Earth entry for blunt-body spacecraft using simple correlations that closely match estimates from NASA's high-fidelity ablation modeling tool, the Fully Implicit Ablation and Thermal Analysis Program (FIAT). These MERs provide a first order estimate for rapid feasibility studies. There are 840 different trajectories considered in this study, and each TPS MER has a peak heating limit. MERs for the vehicle forebody include the ablators Phenolic Impregnated Carbon Ablator (PICA) and Carbon Phenolic atop Advanced Carbon-Carbon. For the aftbody, the materials are Silicone Impregnated Reusable Ceramic Ablator (SIRCA), Acusil II, SLA-561V, and LI-900. The MERs are accurate to within 14% (at one standard deviation) of FIAT prediction, and the most any MER under predicts FIAT TPS thickness is 18.7%. This work focuses on the development of these MERs, the resulting equations, model limitations, and model accuracy.

  2. Multi-qubit gates protected by adiabaticity and dynamical decoupling applicable to donor qubits in silicon

    DOE PAGES

    Witzel, Wayne; Montano, Ines; Muller, Richard P.; ...

    2015-08-19

    In this paper, we present a strategy for producing multiqubit gates that promise high fidelity with minimal tuning requirements. Our strategy combines gap protection from the adiabatic theorem with dynamical decoupling in a complementary manner. Energy-level transition errors are protected by adiabaticity and remaining phase errors are mitigated via dynamical decoupling. This is a powerful way to divide and conquer the various error channels. In order to accomplish this without violating a no-go theorem regarding black-box dynamically corrected gates [Phys. Rev. A 80, 032314 (2009)], we require a robust operating point (sweet spot) in control space where the qubits interactmore » with little sensitivity to noise. There are also energy gap requirements for effective adiabaticity. We apply our strategy to an architecture in Si with P donors where we assume we can shuttle electrons between different donors. Electron spins act as mobile ancillary qubits and P nuclear spins act as long-lived data qubits. Furthermore, this system can have a very robust operating point where the electron spin is bound to a donor in the quadratic Stark shift regime. High fidelity single qubit gates may be performed using well-established global magnetic resonance pulse sequences. Single electron-spin preparation and measurement has also been demonstrated. Thus, putting this all together, we present a robust universal gate set for quantum computation.« less

  3. Towards high fidelity numerical wave tanks for modelling coastal and ocean engineering processes

    NASA Astrophysics Data System (ADS)

    Cozzuto, G.; Dimakopoulos, A.; de Lataillade, T.; Kees, C. E.

    2017-12-01

    With the increasing availability of computational resources, the engineering and research community is gradually moving towards using high fidelity Comutational Fluid Mechanics (CFD) models to perform numerical tests for improving the understanding of physical processes pertaining to wave propapagation and interaction with the coastal environment and morphology, either physical or man-made. It is therefore important to be able to reproduce in these models the conditions that drive these processes. So far, in CFD models the norm is to use regular (linear or nonlinear) waves for performing numerical tests, however, only random waves exist in nature. In this work, we will initially present the verification and validation of numerical wave tanks based on Proteus, an open-soruce computational toolkit based on finite element analysis, with respect to the generation, propagation and absorption of random sea states comprising of long non-repeating wave sequences. Statistical and spectral processing of results demonstrate that the methodologies employed (including relaxation zone methods and moving wave paddles) are capable of producing results of similar quality to the wave tanks used in laboratories (Figure 1). Subsequently cases studies of modelling complex process relevant to coastal defences and floating structures such as sliding and overturning of composite breakwaters, heave and roll response of floating caissons are presented. Figure 1: Wave spectra in the numerical wave tank (coloured symbols), compared against the JONSWAP distribution

  4. AOSLO: from benchtop to clinic

    NASA Astrophysics Data System (ADS)

    Zhang, Yuhua; Poonja, Siddharth; Roorda, Austin

    2006-08-01

    We present a clinically deployable adaptive optics scanning laser ophthalmoscope (AOSLO) that features micro-electro-mechanical (MEMS) deformable mirror (DM) based adaptive optics (AO) and low coherent light sources. With the miniaturized optical aperture of a μDMS-Multi TM MEMS DM (Boston Micromachines Corporation, Watertown, MA), we were able to develop a compact and robust AOSLO optical system that occupies a 50 cm X 50 cm area on a mobile optical table. We introduced low coherent light sources, which are superluminescent laser diodes (SLD) at 680 nm with 9 nm bandwidth and 840 nm with 50 nm bandwidth, in confocal scanning ophthalmoscopy to eliminate interference artifacts in the images. We selected a photo multiplier tube (PMT) for photon signal detection and designed low noise video signal conditioning circuits. We employed an acoustic-optical (AOM) spatial light modulator to modulate the light beam so that we could avoid unnecessary exposure to the retina or project a specific stimulus pattern onto the retina. The MEMS DM based AO system demonstrated robust performance. The use of low coherent light sources effectively mitigated the interference artifacts in the images and yielded high-fidelity retinal images of contiguous cone mosaic. We imaged patients with inherited retinal degenerations including cone-rod dystrophy (CRD) and retinitis pigmentosa (RP). We have produced high-fidelity, real-time, microscopic views of the living human retina for healthy and diseased eyes.

  5. High-Fidelity Down-Conversion Source for Secure Communications Using On-Demand Single Photons

    NASA Technical Reports Server (NTRS)

    Roberts, Tony

    2015-01-01

    AdvR, Inc., has built an efficient, fully integrated, waveguide-based source of spectrally uncorrelated photon pairs that will accelerate research and development (R&D) in the emerging field of quantum information science. Key to the innovation is the use of submicron periodically poled waveguides to produce counter propagating photon pairs, which is enabled by AdvR's patented segmented microelectrode poling technique. This novel device will provide a high brightness source of down-conversion pairs with enhanced spectral properties and low attenuation, and it will operate in the visible to the mid-infrared spectral region. A waveguide-based source of spectrally and spatially pure heralded photons will contribute to a wide range of NASA's advanced technology development efforts, including on-demand single photon sources for high-rate spaced-based secure communications.

  6. Pattern fidelity in nanoimprinted films using CD-SAXS

    NASA Astrophysics Data System (ADS)

    Jones, Ronald L.; Soles, Christopher L.; Lin, Eric K.; Hu, Walter; Reano, Ronald M.; Pang, Stella W.; Weigand, Steven J.; Keane, Denis T.; Quintana, John P.

    2005-05-01

    The primary measure of process quality in nanoimprint lithography (NIL) is the fidelity of pattern transfer, comparing the dimensions of the imprinted pattern to those of the mold. As a potential next generation lithography, NIL is capable of true nanofabrication, producing patterns of sub-10 nm dimensions. Routine production of nanoscale patterns will require new metrologies capable of non-destructive dimensional measurements of both the mold and the pattern with sub-nm precision. In this article, a rapid, non-destructive technique termed Critical Dimension Small Angle X-ray Scattering (CD-SAXS) is used to measure the cross sectional shape of both a pattern master, or mold, and the resulting imprinted films. CD-SAXS data are used to extract periodicity as well as pattern height, width, and sidewall angles. Films of varying materials are molded by thermal embossed NIL at temperatures both near and far from the bulk glass transition (TG). The polymer systems include a photoresist, representing a mixture of a polymer and small molecular components, and two pure homopolymers. Molding at low temperatures (T-TG < 40°C) produces small aspect ratio patterns that maintain periodicity to within a single nanometer, but feature large sidewall angles. While the pattern height does not reach that of the mold until very large imprinting temperatures (T-TG ~ 70°C), the pattern width of the mold is accurately transferred for T-TG > 30°C. In addition to obtaining basic dimensions, CD-SAXS data are used to assess the origin of loss in pattern fidelity.

  7. Implementation fidelity of a computer-assisted intervention for children with speech sound disorders.

    PubMed

    McCormack, Jane; Baker, Elise; Masso, Sarah; Crowe, Kathryn; McLeod, Sharynne; Wren, Yvonne; Roulstone, Sue

    2017-06-01

    Implementation fidelity refers to the degree to which an intervention or programme adheres to its original design. This paper examines implementation fidelity in the Sound Start Study, a clustered randomised controlled trial of computer-assisted support for children with speech sound disorders (SSD). Sixty-three children with SSD in 19 early childhood centres received computer-assisted support (Phoneme Factory Sound Sorter [PFSS] - Australian version). Educators facilitated the delivery of PFSS targeting phonological error patterns identified by a speech-language pathologist. Implementation data were gathered via (1) the computer software, which recorded when and how much intervention was completed over 9 weeks; (2) educators' records of practice sessions; and (3) scoring of fidelity (intervention procedure, competence and quality of delivery) from videos of intervention sessions. Less than one-third of children received the prescribed number of days of intervention, while approximately one-half participated in the prescribed number of intervention plays. Computer data differed from educators' data for total number of days and plays in which children participated; the degree of match was lower as data became more specific. Fidelity to intervention procedures, competency and quality of delivery was high. Implementation fidelity may impact intervention outcomes and so needs to be measured in intervention research; however, the way in which it is measured may impact on data.

  8. Proofreading of DNA polymerase: a new kinetic model with higher-order terminal effects

    NASA Astrophysics Data System (ADS)

    Song, Yong-Shun; Shu, Yao-Gen; Zhou, Xin; Ou-Yang, Zhong-Can; Li, Ming

    2017-01-01

    The fidelity of DNA replication by DNA polymerase (DNAP) has long been an important issue in biology. While numerous experiments have revealed details of the molecular structure and working mechanism of DNAP which consists of both a polymerase site and an exonuclease (proofreading) site, there were quite a few theoretical studies on the fidelity issue. The first model which explicitly considered both sites was proposed in the 1970s and the basic idea was widely accepted by later models. However, all these models did not systematically investigate the dominant factor on DNAP fidelity, i.e. the higher-order terminal effects through which the polymerization pathway and the proofreading pathway coordinate to achieve high fidelity. In this paper, we propose a new and comprehensive kinetic model of DNAP based on some recent experimental observations, which includes previous models as special cases. We present a rigorous and unified treatment of the corresponding steady-state kinetic equations of any-order terminal effects, and derive analytical expressions for fidelity in terms of kinetic parameters under bio-relevant conditions. These expressions offer new insights on how the higher-order terminal effects contribute substantially to the fidelity in an order-by-order way, and also show that the polymerization-and-proofreading mechanism is dominated only by very few key parameters. We then apply these results to calculate the fidelity of some real DNAPs, which are in good agreements with previous intuitive estimates given by experimentalists.

  9. The effects of using high-fidelity simulators and standardized patients on the thorax, lung, and cardiac examination skills of undergraduate nursing students.

    PubMed

    Tuzer, Hilal; Dinc, Leyla; Elcin, Melih

    2016-10-01

    Existing research literature indicates that the use of various simulation techniques in the training of physical examination skills develops students' cognitive and psychomotor abilities in a realistic learning environment while improving patient safety. The study aimed to compare the effects of the use of a high-fidelity simulator and standardized patients on the knowledge and skills of students conducting thorax-lungs and cardiac examinations, and to explore the students' views and learning experiences. A mixed-method explanatory sequential design. The study was conducted in the Simulation Laboratory of a Nursing School, the Training Center at the Faculty of Medicine, and in the inpatient clinics of the Education and Research Hospital. Fifty-two fourth-year nursing students. Students were randomly assigned to Group I and Group II. The students in Group 1 attended the thorax-lungs and cardiac examination training using a high-fidelity simulator, while the students in Group 2 using standardized patients. After the training sessions, all students practiced their skills on real patients in the clinical setting under the supervision of the investigator. Knowledge and performance scores of all students increased following the simulation activities; however, the students that worked with standardized patients achieved significantly higher knowledge scores than those that worked with the high-fidelity simulator; however, there was no significant difference in performance scores between the groups. The mean performance scores of students on real patients were significantly higher compared to the post-simulation assessment scores (p<0.001). Results of this study revealed that use of standardized patients was more effective than the use of a high-fidelity simulator in increasing the knowledge scores of students on thorax-lungs and cardiac examinations; however, practice on real patients increased performance scores of all students without any significant difference in two groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. An experimental study on the effects of a simulation game on students' clinical cognitive skills and motivation.

    PubMed

    Dankbaar, Mary E W; Alsma, Jelmer; Jansen, Els E H; van Merrienboer, Jeroen J G; van Saase, Jan L C M; Schuit, Stephanie C E

    2016-08-01

    Simulation games are becoming increasingly popular in education, but more insight in their critical design features is needed. This study investigated the effects of fidelity of open patient cases in adjunct to an instructional e-module on students' cognitive skills and motivation. We set up a three-group randomized post-test-only design: a control group working on an e-module; a cases group, combining the e-module with low-fidelity text-based patient cases, and a game group, combining the e-module with a high-fidelity simulation game with the same cases. Participants completed questionnaires on cognitive load and motivation. After a 4-week study period, blinded assessors rated students' cognitive emergency care skills in two mannequin-based scenarios. In total 61 students participated and were assessed; 16 control group students, 20 cases students and 25 game students. Learning time was 2 h longer for the cases and game groups than for the control group. Acquired cognitive skills did not differ between groups. The game group experienced higher intrinsic and germane cognitive load than the cases group (p = 0.03 and 0.01) and felt more engaged (p < 0.001). Students did not profit from working on open cases (in adjunct to an e-module), which nonetheless challenged them to study longer. The e-module appeared to be very effective, while the high-fidelity game, although engaging, probably distracted students and impeded learning. Medical educators designing motivating and effective skills training for novices should align case complexity and fidelity with students' proficiency level. The relation between case-fidelity, motivation and skills development is an important field for further study.

  11. Customizing a Research-Based Reading Practice: Balancing the Importance of Implementation Fidelity with Professional Judgment

    ERIC Educational Resources Information Center

    McMaster, Kristen L.; Jung, Pyung-Gang; Brandes, Dana; Pinto, Viveca; Fuchs, Douglas; Kearns, Devin; Lemons, Christopher; Sáenz, Laura; Yen, Loulee

    2014-01-01

    Teachers are often asked to implement research-based instructional programs with fidelity and to ensure that all students reach high academic standards. These requests sometimes conflict when teachers find that not all their students are benefiting from the research-backed programs. In this article, we suggest that researchers and teachers can…

  12. Experimental purification of two-atom entanglement.

    PubMed

    Reichle, R; Leibfried, D; Knill, E; Britton, J; Blakestad, R B; Jost, J D; Langer, C; Ozeri, R; Seidelin, S; Wineland, D J

    2006-10-19

    Entanglement is a necessary resource for quantum applications--entanglement established between quantum systems at different locations enables private communication and quantum teleportation, and facilitates quantum information processing. Distributed entanglement is established by preparing an entangled pair of quantum particles in one location, and transporting one member of the pair to another location. However, decoherence during transport reduces the quality (fidelity) of the entanglement. A protocol to achieve entanglement 'purification' has been proposed to improve the fidelity after transport. This protocol uses separate quantum operations at each location and classical communication to distil high-fidelity entangled pairs from lower-fidelity pairs. Proof-of-principle experiments distilling entangled photon pairs have been carried out. However, these experiments obtained distilled pairs with a low probability of success and required destruction of the entangled pairs, rendering them unavailable for further processing. Here we report efficient and non-destructive entanglement purification with atomic quantum bits. Two noisy entangled pairs were created and distilled into one higher-fidelity pair available for further use. Success probabilities were above 35 per cent. The many applications of entanglement purification make it one of the most important techniques in quantum information processing.

  13. Long-term cryopreservation of Greek fir embryogenic cell lines: recovery, maturation and genetic fidelity.

    PubMed

    Krajňáková, Jana; Sutela, Suvi; Aronen, Tuija; Gömöry, Dušan; Vianello, Angelo; Häggman, Hely

    2011-08-01

    In coniferous species, including Greek fir (Abies cephalonica Loud), the involvement of somatic embryo plants in breeding and reforestation programs is dependent on the success of long-term cryostorage of embryogenic cultures during clonal field testing. In the present study on Greek fir, we assayed the recovery, morphological characteristics and genetic fidelity of embryogenic cell lines 6 and 8 during proliferation and maturation after long-term cryostorage. Our results indicate successful recovery of both cell lines after 6 years in cryostorage. In the maturation phase, both cell lines were capable of producing somatic embryos although some differences were detected among experiments. However, these changes were more dependent on the differences in the components of the maturation media or in the experimental set-up than on the long-term cryostorage. During both proliferation and maturation phases, the morphological fidelity of the embryogenic cultures as well as of the somatic embryos were alike before and after cryopreservation. The genetic fidelity of the cryopreserved cell line 6 that was assayed by random amplified polymorphic DNA (i.e. RAPD) markers demonstrated some changes in the RAPD profiles. The results indicate possible genetic aberrations caused by long-term cryopreservation or somaclonal variation during the proliferation stage. However, in spite of these changes the embryogenic cultures did not lose their proliferation or maturation abilities. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Decoherence and Fidelity in Teleportation of Coherent Photon-Added Two-Mode Squeezed Thermal States

    NASA Astrophysics Data System (ADS)

    Li, Heng-Mei; Yuan, Hong-Chun; Wan, Zhi-Long; Wang, Zhen

    2018-04-01

    We theoretically introduce a kind of non-Gaussian entangled resources, i.e., coherent photon-added two-mode squeezed thermal states (CPA-TMSTS), by successively performing coherent photon addition operation to the two-mode squeezed thermal states. The normalization factor related to bivariate Hermite polynomials is obtained. Based upon it, the nonclassicality and decoherence process are analyzed by virtue of the Wigner function. It is shown that the coherent photon addition operation is an effective way in generating partial negative values of Wigner function, which clearly manifests the nonclassicality and non-Gaussianity of the target states. Additionally, the fidelity in teleporting coherent states using CPA-TMSTS as entangled resource is quantified both analytically and numerically. It is found that the CPA-TMSTS is an entangled resource of high-efficiency and high-fidelity in quantum teleportation.

  15. Roseate Tern breeding dispersal and fidelity: Responses to two newly restored colony sites

    USGS Publications Warehouse

    Spendelow, Jeffrey A.; Monticelli, David; Nichols, James D.; Hines, James; Nisbet, Ian; Cormons, Grace; Hays, Helen; Hatch, Jeremy; Mostello, Carolyn

    2016-01-01

    We used 22 yr of capture–mark–reencounter (CMR) data collected from 1988 to 2009 on about 12,500 birds at what went from three to five coastal colony sites in Massachusetts, New York, and Connecticut, United States, to examine spatial and temporal variation in breeding dispersal/fidelity rates of adult Roseate Terns (Sterna dougallii). At the start of our study, Roseate Terns nested at only one site (Bird Island) in Buzzards Bay, Massachusetts, but two more sites in this bay (Ram and Penikese Islands) were subsequently recolonized and became incorporated into our CMR metapopulation study. We examined four major hypotheses about factors we thought might influence colony-site fidelity and movement rates in the restructured system. We found some evidence that colony-site fidelity remained higher at long-established sites compared with newer ones and that breeding dispersal was more likely to occur among nearby sites than distant ones. Sustained predation at Falkner Island, Connecticut, did not result in a sustained drop in fidelity rates of breeders. Patterns of breeding dispersal differed substantially at the two restored sites. The fidelity of Roseate Terns at Bird dropped quickly after nearby Ram was recolonized in 1994, and fidelity rates for Ram soon approached those for Bird. After an oil spill in Buzzards Bay in April 2003, hazing (deliberate disturbance) of the terns at Ram prior to the start of egg-laying resulted in lowering of fidelity at this site, a decrease in immigration from Bird, and recolonization of Penikese by Roseate Terns. Annual fidelity rates at Penikese increased somewhat several years after the initial recolonization, but they remained much lower there than at all the other sites throughout the study period. The sustained high annual rates of emigration from Penikese resulted in the eventual failure of the restoration effort there, and in 2013, no Roseate Terns nested at this site.

  16. High-Fidelity e-Learning: SEI’s Virtual Training Environment (VTE)

    DTIC Science & Technology

    2009-01-01

    Assessment 2.4 Collaboration 2.4.1 Peer-Student Collaboration 2.4.2 Instructor Support 2.5 Accessibility 2.6 Modularity 2.6.1 Design for Re-Use 2.6.2 Design ...ing Environment as an implementation of a high-fidelity e-Ieaming system. This report does not cover concepts of pedagogy or instructional design in e...pedagogical agents. This is the basis for Clark and Mayer’s Personalization principle for designing media for e-learning [Clark & Mayer 2003]. E-learning

  17. Reconfigurable Image Generator

    NASA Technical Reports Server (NTRS)

    Archdeacon, John L. (Inventor); Iwai, Nelson H. (Inventor); Kato, Kenji H. (Inventor); Sweet, Barbara T. (Inventor)

    2017-01-01

    A RiG may simulate visual conditions of a real world environment, and generate the necessary amount of pixels in a visual simulation at rates up to 120 frames per second. RiG may also include a database generation system capable of producing visual databases suitable to drive the visual fidelity required by the RiG.

  18. Translating staff experience into organisational improvement: the HEADS-UP stepped wedge, cluster controlled, non-randomised trial

    PubMed Central

    Athanasiou, Thanos; Long, Susannah J; Beveridge, Iain; Sevdalis, Nick

    2017-01-01

    Objectives Frontline insights into care delivery correlate with patients’ clinical outcomes. These outcomes might be improved through near-real time identification and mitigation of staff concerns. We evaluated the effects of a prospective frontline surveillance system on patient and team outcomes. Design Prospective, stepped wedge, non-randomised, cluster controlled trial; prespecified per protocol analysis for high-fidelity intervention delivery. Participants Seven interdisciplinary medical ward teams from two hospitals in the UK. Intervention Prospective clinical team surveillance (PCTS): structured daily interdisciplinary briefings to capture staff concerns, with organisational facilitation and feedback. Main measures The primary outcome was excess length of stay (eLOS): an admission more than 24 hours above the local average for comparable patients. Secondary outcomes included safety and teamwork climates, and incident reporting. Mixed-effects models adjusted for time effects, age, comorbidity, palliation status and ward admissions. Safety and teamwork climates were measured with the Safety Attitudes Questionnaire. High-fidelity PCTS delivery comprised high engagement and high briefing frequency. Results Implementation fidelity was variable, both in briefing frequency (median 80% working days/month, IQR 65%–90%) and engagement (median 70 issues/ward/month, IQR 34–113). 1714/6518 (26.3%) intervention admissions had eLOS versus 1279/4927 (26.0%) control admissions, an absolute risk increase of 0.3%. PCTS increased eLOS in the adjusted intention-to-treat model (OR 1.32, 95% CI 1.10 to 1.58, p=0.003). Conversely, high-fidelity PCTS reduced eLOS (OR 0.79, 95% CI 0.67 to 0.94, p=0.006). High-fidelity PCTS also increased total, high-yield and non-nurse incident reports (incidence rate ratios 1.28–1.79, all p<0.002). Sustained PCTS significantly improved safety and teamwork climates over time. Conclusions This study highlighted the potential benefits and pitfalls of ward-level interdisciplinary interventions. While these interventions can improve care delivery in complex, fluid environments, the manner of their implementation is paramount. Suboptimal implementation may have an unexpectedly negative impact on performance. Trial registration number ISRCTN 34806867 (http://www.isrctn.com/ISRCTN34806867). PMID:28720612

  19. Nurses' fidelity to theory-based core components when implementing Family Health Conversations - a qualitative inquiry.

    PubMed

    Östlund, Ulrika; Bäckström, Britt; Lindh, Viveca; Sundin, Karin; Saveman, Britt-Inger

    2015-09-01

    A family systems nursing intervention, Family Health Conversation, has been developed in Sweden by adapting the Calgary Family Assessment and Intervention Models and the Illness Beliefs Model. The intervention has several theoretical assumptions, and one way translate the theory into practice is to identify core components. This may produce higher levels of fidelity to the intervention. Besides information about how to implement an intervention in accordance to how it was developed, evaluating whether it was actually implemented as intended is important. Accordingly, we describe the nurses' fidelity to the identified core components of Family Health Conversation. Six nurses, working in alternating pairs, conducted Family Health Conversations with seven families in which a family member younger than 65 had suffered a stroke. The intervention contained a series of three-1-hour conversations held at 2-3 week intervals. The nurses followed a conversation structure based on 12 core components identified from theoretical assumptions. The transcripts of the 21 conversations were analysed using manifest qualitative content analysis with a deductive approach. The 'core components' seemed to be useful even if nurses' fidelity varied among the core components. Some components were followed relatively well, but others were not. This indicates that the process for achieving fidelity to the intervention can be improved, and that it is necessary for nurses to continually learn theory and to practise family systems nursing. We suggest this can be accomplished through reflections, role play and training on the core components. Furthermore, as in this study, joint reflections on how the core components have been implemented can lead to deeper understanding and knowledge of how Family Health Conversation can be delivered as intended. © 2014 Nordic College of Caring Science.

  20. Co-located haptic and 3D graphic interface for medical simulations.

    PubMed

    Berkelman, Peter; Miyasaka, Muneaki; Bozlee, Sebastian

    2013-01-01

    We describe a system which provides high-fidelity haptic feedback in the same physical location as a 3D graphical display, in order to enable realistic physical interaction with virtual anatomical tissue during modelled procedures such as needle driving, palpation, and other interventions performed using handheld instruments. The haptic feedback is produced by the interaction between an array of coils located behind a thin flat LCD screen, and permanent magnets embedded in the instrument held by the user. The coil and magnet configuration permits arbitrary forces and torques to be generated on the instrument in real time according to the dynamics of the simulated tissue by activating the coils in combination. A rigid-body motion tracker provides position and orientation feedback of the handheld instrument to the computer simulation, and the 3D display is produced using LCD shutter glasses and a head-tracking system for the user.

  1. Demonstration of universal parametric entangling gates on a multi-qubit lattice

    PubMed Central

    Reagor, Matthew; Osborn, Christopher B.; Tezak, Nikolas; Staley, Alexa; Prawiroatmodjo, Guenevere; Scheer, Michael; Alidoust, Nasser; Sete, Eyob A.; Didier, Nicolas; da Silva, Marcus P.; Acala, Ezer; Angeles, Joel; Bestwick, Andrew; Block, Maxwell; Bloom, Benjamin; Bradley, Adam; Bui, Catvu; Caldwell, Shane; Capelluto, Lauren; Chilcott, Rick; Cordova, Jeff; Crossman, Genya; Curtis, Michael; Deshpande, Saniya; El Bouayadi, Tristan; Girshovich, Daniel; Hong, Sabrina; Hudson, Alex; Karalekas, Peter; Kuang, Kat; Lenihan, Michael; Manenti, Riccardo; Manning, Thomas; Marshall, Jayss; Mohan, Yuvraj; O’Brien, William; Otterbach, Johannes; Papageorge, Alexander; Paquette, Jean-Philip; Pelstring, Michael; Polloreno, Anthony; Rawat, Vijay; Ryan, Colm A.; Renzas, Russ; Rubin, Nick; Russel, Damon; Rust, Michael; Scarabelli, Diego; Selvanayagam, Michael; Sinclair, Rodney; Smith, Robert; Suska, Mark; To, Ting-Wai; Vahidpour, Mehrnoosh; Vodrahalli, Nagesh; Whyland, Tyler; Yadav, Kamal; Zeng, William; Rigetti, Chad T.

    2018-01-01

    We show that parametric coupling techniques can be used to generate selective entangling interactions for multi-qubit processors. By inducing coherent population exchange between adjacent qubits under frequency modulation, we implement a universal gate set for a linear array of four superconducting qubits. An average process fidelity of ℱ = 93% is estimated for three two-qubit gates via quantum process tomography. We establish the suitability of these techniques for computation by preparing a four-qubit maximally entangled state and comparing the estimated state fidelity with the expected performance of the individual entangling gates. In addition, we prepare an eight-qubit register in all possible bitstring permutations and monitor the fidelity of a two-qubit gate across one pair of these qubits. Across all these permutations, an average fidelity of ℱ = 91.6 ± 2.6% is observed. These results thus offer a path to a scalable architecture with high selectivity and low cross-talk. PMID:29423443

  2. Strong homing does not predict high site fidelity in juvenile reef fishes

    NASA Astrophysics Data System (ADS)

    Streit, Robert P.; Bellwood, David R.

    2018-03-01

    After being displaced, juvenile reef fishes are able to return home over large distances. This strong homing behaviour is extraordinary and may allow insights into the longer-term spatial ecology of fish communities. For example, it appears intuitive that strong homing behaviour should be indicative of long-term site fidelity. However, this connection has rarely been tested. We quantified the site fidelity of juvenile fishes of four species after returning home following displacement. Two species, parrotfishes and Pomacentrus moluccensis, showed significantly reduced site fidelity after returning home. On average, they disappeared from their home sites almost 3 d earlier than expected. Mortality or competitive exclusion does not seem to be the main reasons for their disappearance. Rather, we suggest an increased propensity to relocate after encountering alternative reef locations while homing. It appears that some juvenile fishes may have a higher innate spatial flexibility than their strict homing drive suggests.

  3. The influence of prototype fidelity and aesthetics of design in usability tests: effects on user behaviour, subjective evaluation and emotion.

    PubMed

    Sauer, Juergen; Sonderegger, Andreas

    2009-07-01

    An empirical study examined the impact of prototype fidelity on user behaviour, subjective user evaluation and emotion. The independent factors of prototype fidelity (paper prototype, computer prototype, fully operational appliance) and aesthetics of design (high vs. moderate) were varied in a between-subjects design. The 60 participants of the experiment were asked to complete two typical tasks of mobile phone usage: sending a text message and suppressing a phone number. Both performance data and a number of subjective measures were recorded. The results suggested that task completion time may be overestimated when a computer prototype is being used. Furthermore, users appeared to compensate for deficiencies in aesthetic design by overrating the aesthetic qualities of reduced fidelity prototypes. Finally, user emotions were more positively affected by the operation of the more attractive mobile phone than by the less appealing one.

  4. High-Fidelity Quantum Logic Gates Using Trapped-Ion Hyperfine Qubits.

    PubMed

    Ballance, C J; Harty, T P; Linke, N M; Sepiol, M A; Lucas, D M

    2016-08-05

    We demonstrate laser-driven two-qubit and single-qubit logic gates with respective fidelities 99.9(1)% and 99.9934(3)%, significantly above the ≈99% minimum threshold level required for fault-tolerant quantum computation, using qubits stored in hyperfine ground states of calcium-43 ions held in a room-temperature trap. We study the speed-fidelity trade-off for the two-qubit gate, for gate times between 3.8  μs and 520  μs, and develop a theoretical error model which is consistent with the data and which allows us to identify the principal technical sources of infidelity.

  5. Comparing self-guided learning and educator-guided learning formats for simulation-based clinical training.

    PubMed

    Brydges, Ryan; Carnahan, Heather; Rose, Don; Dubrowski, Adam

    2010-08-01

    In this paper, we tested the over-arching hypothesis that progressive self-guided learning offers equivalent learning benefit vs. proficiency-based training while limiting the need to set proficiency standards. We have shown that self-guided learning is enhanced when students learn on simulators that progressively increase in fidelity during practice. Proficiency-based training, a current gold-standard training approach, requires achievement of a criterion score before students advance to the next learning level. Baccalaureate nursing students (n = 15/group) practised intravenous catheterization using simulators that differed in fidelity (i.e. students' perceived realism). Data were collected in 2008. Proficiency-based students advanced from low- to mid- to high-fidelity after achieving a proficiency criterion at each level. Progressive students self-guided their progression from low- to mid- to high-fidelity. Yoked control students followed an experimenter-defined progressive practice schedule. Open-ended students moved freely between the simulators. One week after practice, blinded experts evaluated students' skill transfer on a standardized patient simulation. Group differences were examined using analyses of variance. Proficiency-based students scored highest on the high-fidelity post-test (effect size = 1.22). An interaction effect showed that the Progressive and Open-ended groups maintained their performance from post-test to transfer test, whereas the Proficiency-based and Yoked control groups experienced a significant decrease (P < 0.05). Surprisingly, most Open-ended students (73%) chose the progressive practice schedule. Progressive training and proficiency-based training resulted in equivalent transfer test performance, suggesting that progressive students effectively self-guided when to transition between simulators. Students' preference for the progressive practice schedule indicates that educators should consider this sequence for simulation-based training.

  6. Patterns of communication in high-fidelity simulation.

    PubMed

    Anderson, Judy K; Nelson, Kimberly

    2015-01-01

    High-fidelity simulation is commonplace in nursing education. However, critical thinking, decision making, and psychomotor skills scenarios are emphasized. Scenarios involving communication occur in interprofessional or intraprofessional settings. The importance of effective nurse-patient communication is reflected in statements from the American Nurses Association and Quality and Safety Education for Nurses, and in the graduate outcomes of most nursing programs. This qualitative study examined the patterns of communication observed in video recordings of a medical-surgical scenario with 71 senior students in a baccalaureate program. Thematic analysis revealed patterns of (a) focusing on tasks, (b) communicating-in-action, and (c) being therapeutic. Additional categories under the patterns included missing opportunities, viewing the "small picture," relying on informing, speaking in "medical tongues," offering choices…okay?, feeling uncomfortable, and using therapeutic techniques. The findings suggest the importance of using high-fidelity simulation to develop expertise in communication. In addition, the findings reinforce the recommendation to prioritize communication aspects of scenarios and debriefing for all simulations. Copyright 2015, SLACK Incorporated.

  7. Enhancing pediatric clinical competency with high-fidelity simulation.

    PubMed

    Birkhoff, Susan D; Donner, Carol

    2010-09-01

    In today's tertiary pediatric hospital setting, the increased complexity of patient care demands seamless coordination and collaboration among multidisciplinary team members. In an effort to enhance patient safety, clinical competence, and teamwork, simulation-based learning has become increasingly integrated into pediatric clinical practice as an innovative educational strategy. The simulated setting provides a risk-free environment where learners can incorporate cognitive, psychomotor, and affective skill acquisition without fear of harming patients. One pediatric university hospital in Southeastern Pennsylvania has enhanced the traditional American Heart Association (AHA) Pediatric Advanced Life Support (PALS) course by integrating high-fidelity simulation into skill acquisition, while still functioning within the guidelines and framework of the AHA educational standards. However, very little research with reliable standardized testing methods has been done to measure the effect of simulation-based learning. This article discusses the AHA guidelines for PALS, evaluation of PALS and nursing clinical competencies, communication among a multidisciplinary team, advantages and disadvantages of simulation, incorporation of high-fidelity simulation into pediatric practice, and suggestions for future practice. Copyright 2010, SLACK Incorporated.

  8. The nature of reality represented in high fidelity human patient simulation: philosophical perspectives and implications for nursing education.

    PubMed

    Dunnington, Renee M

    2014-01-01

    Simulation technology is increasingly being used in nursing education. Previously used primarily for teaching procedural, instrumental, or critical incident types of skills, simulation is now being applied to training related to more dynamic, complex, and interpersonal human contexts. While high fidelity human patient simulators have significantly increased in authenticity, human responses have greater complexity and are qualitatively different than current technology represents. This paper examines the texture of representation by simulation. Through a tracing of historical and contemporary philosophical perspectives on simulation, the nature and limits of the reality of human health responses represented by high fidelity human patient simulation (HF-HPS) are explored. Issues concerning nursing education are raised around the nature of reality represented in HF-HPS. Drawing on Waks, a framework for guiding pedagogical considerations around simulation in nursing education is presented for the ultimate purpose of promoting an educative experience with simulation. © 2013 John Wiley & Sons Ltd.

  9. Coupling two spin qubits with a high-impedance resonator

    NASA Astrophysics Data System (ADS)

    Harvey, S. P.; Bøttcher, C. G. L.; Orona, L. A.; Bartlett, S. D.; Doherty, A. C.; Yacoby, A.

    2018-06-01

    Fast, high-fidelity single and two-qubit gates are essential to building a viable quantum information processor, but achieving both in the same system has proved challenging for spin qubits. We propose and analyze an approach to perform a long-distance two-qubit controlled phase (CPHASE) gate between two singlet-triplet qubits using an electromagnetic resonator to mediate their interaction. The qubits couple longitudinally to the resonator, and by driving the qubits near the resonator's frequency, they can be made to acquire a state-dependent geometric phase that leads to a CPHASE gate independent of the initial state of the resonator. Using high impedance resonators enables gate times of order 10 ns while maintaining long coherence times. Simulations show average gate fidelities of over 96% using currently achievable experimental parameters and over 99% using state-of-the-art resonator technology. After optimizing the gate fidelity in terms of parameters tuneable in situ, we find it takes a simple power-law form in terms of the resonator's impedance and quality and the qubits' noise bath.

  10. Installing the Communities that Care Prevention System: Implementation Progress and Fidelity in a Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Quinby, Rose K.; Hanson, Koren; Brooke-Weiss, Blair; Arthur, Michael W.; Hawkins, J. David; Fagan, Abigail A.

    2008-01-01

    This article describes the degree to which high fidelity implementation of the Communities That Care (CTC) prevention operating system was reached during the first 18 months of intervention in 12 communities in the Community Youth Development Study, a 5-year group randomized controlled trial designed to test the efficacy of the CTC system. CTC…

  11. An Analysis of the Educational Value of Low-Fidelity Anatomy Models as External Representations

    ERIC Educational Resources Information Center

    Chan, Lap Ki; Cheng, Maurice M. W.

    2011-01-01

    Although high-fidelity digital models of human anatomy based on actual cross-sectional images of the human body have been developed, reports on the use of physical models in anatomy teaching continue to appear. This article aims to examine the common features shared by these physical models and analyze their educational value based on the…

  12. Long Live Love+: Evaluation of the Implementation of an Online School-Based Sexuality Education Program in the Netherlands

    ERIC Educational Resources Information Center

    van Lieshout, Sanne; Mevissen, Fraukje; de Waal, Esri; Kok, Gerjo

    2017-01-01

    Schools are a common setting for adolescents to receive health education, but implementation of these programs with high levels of completeness and fidelity is not self-evident. Programs that are only partially implemented (completeness) or not implemented as instructed (fidelity) are unlikely to be effective. Therefore, it is important to…

  13. Transmission fidelity is the key to the build-up of cumulative culture

    PubMed Central

    Lewis, Hannah M.; Laland, Kevin N.

    2012-01-01

    Many animals have socially transmitted behavioural traditions, but human culture appears unique in that it is cumulative, i.e. human cultural traits increase in diversity and complexity over time. It is often suggested that high-fidelity cultural transmission is necessary for cumulative culture to occur through refinement, a process known as ‘ratcheting’, but this hypothesis has never been formally evaluated. We discuss processes of information transmission and loss of traits from a cognitive viewpoint alongside other cultural processes of novel invention (generation of entirely new traits), modification (refinement of existing traits) and combination (bringing together two established traits to generate a new trait). We develop a simple cultural transmission model that does not assume major evolutionary changes (e.g. in brain architecture) and show that small changes in the fidelity with which information is passed between individuals can lead to cumulative culture. In comparison, modification and combination have a lesser influence on, and novel invention appears unimportant to, the ratcheting process. Our findings support the idea that high-fidelity transmission is the key driver of human cumulative culture, and that progress in cumulative culture depends more on trait combination than novel invention or trait modification. PMID:22734060

  14. Fidelity and over-wintering of sea turtles

    PubMed Central

    Broderick, Annette C; Coyne, Michael S; Fuller, Wayne J; Glen, Fiona; Godley, Brendan J

    2007-01-01

    While fidelity to breeding sites is well demonstrated in marine turtles, emerging knowledge of migratory routes and key foraging sites is of limited conservation value unless levels of fidelity can be established. We tracked green (Chelonia mydas, n=10) and loggerhead (Caretta caretta, n=10) turtles during their post-nesting migration from the island of Cyprus to their foraging grounds. After intervals of 2–5 years, five of these females were recaptured at the nesting beach and tracked for a second migration. All five used highly similar migratory routes to return to the same foraging and over-wintering areas. None of the females visited other foraging habitats over the study period (units lasted on average 305 days; maximum, 1356 days), moving only to deeper waters during the winter months where they demonstrated extremely long resting dives of up to 10.2 h (the longest breath-holding dive recorded for a marine vertebrate). High levels of fidelity and the relatively discrete nature of the home ranges demonstrate that protection of key migratory pathways, foraging and over-wintering sites can serve as an important tool for the future conservation of marine turtles. PMID:17456456

  15. Organic preservation of fossil musculature with ultracellular detail

    PubMed Central

    McNamara, Maria; Orr, Patrick J.; Kearns, Stuart L.; Alcalá, Luis; Anadón, Pere; Peñalver-Mollá, Enrique

    2010-01-01

    The very labile (decay-prone), non-biomineralized, tissues of organisms are rarely fossilized. Occurrences thereof are invaluable supplements to a body fossil record dominated by biomineralized tissues, which alone are extremely unrepresentative of diversity in modern and ancient ecosystems. Fossil examples of extremely labile tissues (e.g. muscle) that exhibit a high degree of morphological fidelity are almost invariably replicated by inorganic compounds such as calcium phosphate. There is no consensus as to whether such tissues can be preserved with similar morphological fidelity as organic remains, except when enclosed inside amber. Here, we report fossilized musculature from an approximately 18 Myr old salamander from lacustrine sediments of Ribesalbes, Spain. The muscle is preserved organically, in three dimensions, and with the highest fidelity of morphological preservation yet documented from the fossil record. Preserved ultrastructural details include myofilaments, endomysium, layering within the sarcolemma, and endomysial circulatory vessels infilled with blood. Slight differences between the fossil tissues and their counterparts in extant amphibians reflect limited degradation during fossilization. Our results provide unequivocal evidence that high-fidelity organic preservation of extremely labile tissues is not only feasible, but likely to be common. This is supported by the discovery of similarly preserved tissues in the Eocene Grube Messel biota. PMID:19828545

  16. Transmission fidelity is the key to the build-up of cumulative culture.

    PubMed

    Lewis, Hannah M; Laland, Kevin N

    2012-08-05

    Many animals have socially transmitted behavioural traditions, but human culture appears unique in that it is cumulative, i.e. human cultural traits increase in diversity and complexity over time. It is often suggested that high-fidelity cultural transmission is necessary for cumulative culture to occur through refinement, a process known as 'ratcheting', but this hypothesis has never been formally evaluated. We discuss processes of information transmission and loss of traits from a cognitive viewpoint alongside other cultural processes of novel invention (generation of entirely new traits), modification (refinement of existing traits) and combination (bringing together two established traits to generate a new trait). We develop a simple cultural transmission model that does not assume major evolutionary changes (e.g. in brain architecture) and show that small changes in the fidelity with which information is passed between individuals can lead to cumulative culture. In comparison, modification and combination have a lesser influence on, and novel invention appears unimportant to, the ratcheting process. Our findings support the idea that high-fidelity transmission is the key driver of human cumulative culture, and that progress in cumulative culture depends more on trait combination than novel invention or trait modification.

  17. PCR amplification of up to 35-kb DNA with high fidelity and high yield from lambda bacteriophage templates.

    PubMed Central

    Barnes, W M

    1994-01-01

    A target length limitation to PCR amplification of DNA has been identified and addressed. Concomitantly, the base-pair fidelity, the ability to use PCR products as primers, and the maximum yield of target fragment were increased. These improvements were achieved by the combination of a high level of an exonuclease-free, N-terminal deletion mutant of Taq DNA polymerase, Klentaq1, with a very low level of a thermostable DNA polymerase exhibiting a 3'-exonuclease activity (Pfu, Vent, or Deep Vent). At least 35 kb can be amplified to high yields from 1 ng of lambda DNA template. Images PMID:8134376

  18. A high repetition deterministic single ion source

    NASA Astrophysics Data System (ADS)

    Sahin, C.; Geppert, P.; Müllers, A.; Ott, H.

    2017-12-01

    We report on a deterministic single ion source with high repetition rate and high fidelity. The source employs a magneto-optical trap, where ultracold rubidium atoms are photoionized. The electrons herald the creation of a corresponding ion, whose timing information is used to manipulate its trajectory in flight. We demonstrate an ion rate of up to 4× {10}4 {{{s}}}-1 and achieve a fidelity for single ion operation of 98%. The technique can be used for all atomic species, which can be laser-cooled, and opens up new applications in ion microscopy, ion implantation and surface spectroscopy.

  19. Towards developing high-fidelity simulated learning environment training modules in audiology.

    PubMed

    Dzulkarnain, A A; Rahmat, S; Mohd Puzi, N A F; Badzis, M

    2017-02-01

    This discussion paper reviews and synthesises the literature on simulated learning environment (SLE) from allied health sciences, medical and nursing in general and audiology specifically. The focus of the paper is on discussing the use of high-fidelity (HF) SLE and describing the challenges for developing a HF SLE for clinical audiology training. Through the review of the literature, this paper discusses seven questions, (i) What is SLE? (ii) What are the types of SLEs? (iii) How is SLE classified? (iv) What is HF SLE? (v) What types of SLEs are available in audiology and their level of fidelity? (vi) What are the components needed for developing HF SLE? (vii) What are the possible types of HF SLEs that are suitable for audiology training? Publications were identified by structured searches from three major databases PubMed, Web of Knowledge and PsychInfo and from the reference lists of relevant articles. The authors discussed and mapped the levels of fidelity of SLE audiology training modules from the literature and the learning domains involved in the clinical audiology courses. The discussion paper has highlighted that most of the existing SLE audiology training modules consist of either low- or medium-fidelity types of simulators. Those components needed to achieve a HF SLE for audiology training are also highlighted. Overall, this review recommends that the combined approach of different levels and types of SLE could be used to obtain a HF SLE training module in audiology training.

  20. High fidelity, low cost moulage as a valid simulation tool to improve burns education.

    PubMed

    Pywell, M J; Evgeniou, E; Highway, K; Pitt, E; Estela, C M

    2016-06-01

    Simulation allows the opportunity for repeated practice in controlled, safe conditions. Moulage uses materials such as makeup to simulate clinical presentations. Moulage fidelity can be assessed by face validity (realism) and content validity (appropriateness). The aim of this project is to compare the fidelity of professional moulage to non-professional moulage in the context of a burns management course. Four actors were randomly assigned to a professional make-up artist or a course faculty member for moulage preparation such that two actors were in each group. Participants completed the actor-based burn management scenarios and answered a ten-question Likert-scale questionnaire on face and content validity. Mean scores and a linear mixed effects model were used to compare professional and non-professional moulage. Cronbach's alpha assessed internal consistency. Twenty participants experienced three out of four scenarios and at the end of the course completed a total of 60 questionnaires. Professional moulage had higher average ratings for face (4.30 v 3.80; p=0.11) and content (4.30 v 4.00; p=0.06) validity. Internal consistency of face (α=0.91) and content (α=0.85) validity questions was very good. The fidelity of professionally prepared moulage, as assessed by content validity, was higher than non-professionally prepared moulage. We have shown that using professional techniques and low cost materials we can prepare quality high fidelity moulage simulations. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  1. A stochastic wind turbine wake model based on new metrics for wake characterization: A stochastic wind turbine wake model based on new metrics for wake characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doubrawa, Paula; Barthelmie, Rebecca J.; Wang, Hui

    Understanding the detailed dynamics of wind turbine wakes is critical to predicting the performance and maximizing the efficiency of wind farms. This knowledge requires atmospheric data at a high spatial and temporal resolution, which are not easily obtained from direct measurements. Therefore, research is often based on numerical models, which vary in fidelity and computational cost. The simplest models produce axisymmetric wakes and are only valid beyond the near wake. Higher-fidelity results can be obtained by solving the filtered Navier-Stokes equations at a resolution that is sufficient to resolve the relevant turbulence scales. This work addresses the gap between thesemore » two extremes by proposing a stochastic model that produces an unsteady asymmetric wake. The model is developed based on a large-eddy simulation (LES) of an offshore wind farm. Because there are several ways of characterizing wakes, the first part of this work explores different approaches to defining global wake characteristics. From these, a model is developed that captures essential features of a LES-generated wake at a small fraction of the cost. The synthetic wake successfully reproduces the mean characteristics of the original LES wake, including its area and stretching patterns, and statistics of the mean azimuthal radius. The mean and standard deviation of the wake width and height are also reproduced. This preliminary study focuses on reproducing the wake shape, while future work will incorporate velocity deficit and meandering, as well as different stability scenarios.« less

  2. Utilizing Adjoint-Based Error Estimates for Surrogate Models to Accurately Predict Probabilities of Events

    DOE PAGES

    Butler, Troy; Wildey, Timothy

    2018-01-01

    In thist study, we develop a procedure to utilize error estimates for samples of a surrogate model to compute robust upper and lower bounds on estimates of probabilities of events. We show that these error estimates can also be used in an adaptive algorithm to simultaneously reduce the computational cost and increase the accuracy in estimating probabilities of events using computationally expensive high-fidelity models. Specifically, we introduce the notion of reliability of a sample of a surrogate model, and we prove that utilizing the surrogate model for the reliable samples and the high-fidelity model for the unreliable samples gives preciselymore » the same estimate of the probability of the output event as would be obtained by evaluation of the original model for each sample. The adaptive algorithm uses the additional evaluations of the high-fidelity model for the unreliable samples to locally improve the surrogate model near the limit state, which significantly reduces the number of high-fidelity model evaluations as the limit state is resolved. Numerical results based on a recently developed adjoint-based approach for estimating the error in samples of a surrogate are provided to demonstrate (1) the robustness of the bounds on the probability of an event, and (2) that the adaptive enhancement algorithm provides a more accurate estimate of the probability of the QoI event than standard response surface approximation methods at a lower computational cost.« less

  3. Development and validation of a high-fidelity phonomicrosurgical trainer.

    PubMed

    Klein, Adam M; Gross, Jennifer

    2017-04-01

    To validate the use of a high-fidelity phonomicrosurgical trainer. A high-fidelity phonomicrosurgical trainer, based on a previously validated model by Contag et al., 1 was designed with multilayered vocal folds that more closely mimic the consistency of true vocal folds, containing intracordal lesions to practice phonomicrosurgical removal. A training module was developed to simulate the true phonomicrosurgical experience. A validation study with novice and expert surgeons was conducted. Novices and experts were instructed to remove the lesion from the synthetic vocal folds, and novices were given four training trials. Performances were measured by the amount of time spent and tissue injury (microflap, superficial, deep) to the vocal fold. An independent Student t test and Fisher exact tests were used to compare subjects. A matched-paired t test and Wilcoxon signed rank tests were used to compare novice performance on the first and fourth trials and assess for improvement. Experts completed the excision with less total errors than novices (P = .004) and made less injury to the microflap (P = .05) and superficial tissue (P = .003). Novices improved their performance with training, making less total errors (P = .002) and superficial tissue injuries (P = .02) and spending less time for removal (P = .002) after several practice trials. This high-fidelity phonomicrosurgical trainer has been validated for novice surgeons. It can distinguish between experts and novices; and after training, it helped to improve novice performance. N/A. Laryngoscope, 127:888-893, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Undergraduate interprofessional education using high-fidelity paediatric simulation.

    PubMed

    Stewart, Moira; Kennedy, Neil; Cuene-Grandidier, Hazel

    2010-06-01

    High-fidelity simulation is becoming increasingly important in the delivery of teaching and learning to health care professionals within a safe environment. Its use in an interprofessional context and at undergraduate level has the potential to facilitate the learning of good communication and teamworking, in addition to clinical knowledge and skills. Interprofessional teaching and learning workshops using high-fidelity paediatric simulation were developed and delivered to undergraduate medical and nursing students at Queen's University Belfast. Learning outcomes common to both professions, and essential in the clinical management of sick children, included basic competencies, communication and teamworking skills. Quantitative and qualitative evaluation was undertaken using published questionnaires. Quantitative results - the 32-item questionnaire was analysed for reliability using spss. Responses were positive for both groups of students across four domains - acquisition of knowledge and skills, communication and teamworking, professional identity and role awareness, and attitudes to shared learning. Qualitative results - thematic content analysis was used to analyse open-ended responses. Students from both groups commented that an interprofessional education (IPE) approach to paediatric simulation improved clinical and practice-based skills, and provided a safe learning environment. Students commented that there should be more interprofessional and simulation learning opportunities. High-fidelity paediatric simulation, used in an interprofessional context, has the potential to meet the requirements of undergraduate medical and nursing curricula. Further research is needed into the long-term benefits for patient care, and its generalisability to other areas within health care teaching and learning. © Blackwell Publishing Ltd 2010.

  5. Utilizing Adjoint-Based Error Estimates for Surrogate Models to Accurately Predict Probabilities of Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, Troy; Wildey, Timothy

    In thist study, we develop a procedure to utilize error estimates for samples of a surrogate model to compute robust upper and lower bounds on estimates of probabilities of events. We show that these error estimates can also be used in an adaptive algorithm to simultaneously reduce the computational cost and increase the accuracy in estimating probabilities of events using computationally expensive high-fidelity models. Specifically, we introduce the notion of reliability of a sample of a surrogate model, and we prove that utilizing the surrogate model for the reliable samples and the high-fidelity model for the unreliable samples gives preciselymore » the same estimate of the probability of the output event as would be obtained by evaluation of the original model for each sample. The adaptive algorithm uses the additional evaluations of the high-fidelity model for the unreliable samples to locally improve the surrogate model near the limit state, which significantly reduces the number of high-fidelity model evaluations as the limit state is resolved. Numerical results based on a recently developed adjoint-based approach for estimating the error in samples of a surrogate are provided to demonstrate (1) the robustness of the bounds on the probability of an event, and (2) that the adaptive enhancement algorithm provides a more accurate estimate of the probability of the QoI event than standard response surface approximation methods at a lower computational cost.« less

  6. Concentration transport calculations by an original C++ program with interediate fidelity physics through user-defined buildings with an emphasis on release scenarios in radiological facilities

    NASA Astrophysics Data System (ADS)

    Sayre, George Anthony

    The purpose of this dissertation was to develop the C ++ program Emergency Dose to calculate transport of radionuclides through indoor spaces using intermediate fidelity physics that provides improved spatial heterogeneity over well-mixed models such as MELCORRTM and much lower computation times than CFD codes such as FLUENTRTM . Modified potential flow theory, which is an original formulation of potential flow theory with additions of turbulent jet and natural convection approximations, calculates spatially heterogeneous velocity fields that well-mixed models cannot predict. Other original contributions of MPFT are: (1) generation of high fidelity boundary conditions relative to well-mixed-CFD coupling methods (conflation), (2) broadening of potential flow applications to arbitrary indoor spaces previously restricted to specific applications such as exhaust hood studies, and (3) great reduction of computation time relative to CFD codes without total loss of heterogeneity. Additionally, the Lagrangian transport module, which is discussed in Sections 1.3 and 2.4, showcases an ensemble-based formulation thought to be original to interior studies. Velocity and concentration transport benchmarks against analogous formulations in COMSOLRTM produced favorable results with discrepancies resulting from the tetrahedral meshing used in COMSOLRTM outperforming the Cartesian method used by Emergency Dose. A performance comparison of the concentration transport modules against MELCORRTM showed that Emergency Dose held advantages over the well-mixed model especially in scenarios with many interior partitions and varied source positions. A performance comparison of velocity module against FLUENTRTM showed that viscous drag provided the largest error between Emergency Dose and CFD velocity calculations, but that Emergency Dose's turbulent jets well approximated the corresponding CFD jets. Overall, Emergency Dose was found to provide a viable intermediate solution method for concentration transport with relatively low computation times.

  7. Overview of High-Fidelity Modeling Activities in the Numerical Propulsion System Simulations (NPSS) Project

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.

    2002-01-01

    A high-fidelity simulation of a commercial turbofan engine has been created as part of the Numerical Propulsion System Simulation Project. The high-fidelity computer simulation utilizes computer models that were developed at NASA Glenn Research Center in cooperation with turbofan engine manufacturers. The average-passage (APNASA) Navier-Stokes based viscous flow computer code is used to simulate the 3D flow in the compressors and turbines of the advanced commercial turbofan engine. The 3D National Combustion Code (NCC) is used to simulate the flow and chemistry in the advanced aircraft combustor. The APNASA turbomachinery code and the NCC combustor code exchange boundary conditions at the interface planes at the combustor inlet and exit. This computer simulation technique can evaluate engine performance at steady operating conditions. The 3D flow models provide detailed knowledge of the airflow within the fan and compressor, the high and low pressure turbines, and the flow and chemistry within the combustor. The models simulate the performance of the engine at operating conditions that include sea level takeoff and the altitude cruise condition.

  8. Room temperature high-fidelity holonomic single-qubit gate on a solid-state spin.

    PubMed

    Arroyo-Camejo, Silvia; Lazariev, Andrii; Hell, Stefan W; Balasubramanian, Gopalakrishnan

    2014-09-12

    At its most fundamental level, circuit-based quantum computation relies on the application of controlled phase shift operations on quantum registers. While these operations are generally compromised by noise and imperfections, quantum gates based on geometric phase shifts can provide intrinsically fault-tolerant quantum computing. Here we demonstrate the high-fidelity realization of a recently proposed fast (non-adiabatic) and universal (non-Abelian) holonomic single-qubit gate, using an individual solid-state spin qubit under ambient conditions. This fault-tolerant quantum gate provides an elegant means for achieving the fidelity threshold indispensable for implementing quantum error correction protocols. Since we employ a spin qubit associated with a nitrogen-vacancy colour centre in diamond, this system is based on integrable and scalable hardware exhibiting strong analogy to current silicon technology. This quantum gate realization is a promising step towards viable, fault-tolerant quantum computing under ambient conditions.

  9. Islands in the sea: extreme female natal site fidelity in the Australian sea lion, Neophoca cinerea.

    PubMed

    Campbell, R A; Gales, N J; Lento, G M; Baker, C S

    2008-02-23

    Pinnipeds (seals, fur seals, sea lions and walrus) form large breeding aggregations with females often remaining faithful to a natal site or area. In these cases, females are philopatric to regional areas on broad geographical scales of hundreds to thousands of kilometers. An investigation of variation in a control region sequence of mtDNA in the Australian sea lion (Neophoca cinerea) has shown a case of extreme female natal site fidelity that has resulted in almost fixed population differentiation across its range (PhiST=0.93). This high level of population subdivision over short geographical distances (approx. 60 km) is unparalleled in any social marine mammal and reflects the unique life-history traits of this rare species. The high level of population subdivision and exclusive female natal site fidelity has important ramifications for conservation management, and poses many interesting questions of both academic and applied interest.

  10. Retrieval of high-fidelity memory arises from distributed cortical networks.

    PubMed

    Wais, Peter E; Jahanikia, Sahar; Steiner, Daniel; Stark, Craig E L; Gazzaley, Adam

    2017-04-01

    Medial temporal lobe (MTL) function is well established as necessary for memory of facts and events. It is likely that lateral cortical regions critically guide cognitive control processes to tune in high-fidelity details that are most relevant for memory retrieval. Here, convergent results from functional and structural MRI show that retrieval of detailed episodic memory arises from lateral cortical-MTL networks, including regions of inferior frontal and angular gyrii. Results also suggest that recognition of items based on low-fidelity, generalized information, rather than memory arising from retrieval of relevant episodic details, is not associated with functional connectivity between MTL and lateral cortical regions. Additionally, individual differences in microstructural properties in white matter pathways, associated with distributed MTL-cortical networks, are positively correlated with better performance on a mnemonic discrimination task. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  11. A Mixed-Fidelity Approach for Design of Low-Boom Supersonic Aircraft

    NASA Technical Reports Server (NTRS)

    Li, Wu; Shields, Elwood; Geiselhart, Karl A.

    2010-01-01

    This paper documents a mixed-fidelity approach for the design of low-boom supersonic aircraft as a viable approach for designing a practical low-boom supersonic configuration. A low-boom configuration that is based on low-fidelity analysis is used as the baseline. Tail lift is included to help tailor the aft portion of the ground signature. A comparison of low- and high-fidelity analysis results demonstrates the necessity of using computational fluid dynamics (CFD) analysis in a low-boom supersonic configuration design process. The fuselage shape is modified iteratively to obtain a configuration with a CFD equivalent-area distribution that matches a predetermined low-boom target distribution. The mixed-fidelity approach can easily refine the low-fidelity low-boom baseline into a low-boom configuration with the use of CFD equivalent-area analysis. The ground signature of the final configuration is calculated by using a state-of-the-art CFD-based boom analysis method that generates accurate midfield pressure distributions for propagation to the ground with ray tracing. The ground signature that is propagated from a midfield pressure distribution has a shaped ramp front, which is similar to the ground signature that is propagated from the CFD equivalent-area distribution. This result confirms the validity of the low-boom supersonic configuration design by matching a low-boom equivalent-area target, which is easier to accomplish than matching a low-boom midfield pressure target.

  12. Importance of single molecular determinants in the fidelity of expanded genetic codes.

    PubMed

    Antonczak, Alicja K; Simova, Zuzana; Yonemoto, Isaac T; Bochtler, Matthias; Piasecka, Anna; Czapinska, Honorata; Brancale, Andrea; Tippmann, Eric M

    2011-01-25

    The site-selective encoding of noncanonical amino acids (NAAs) is a powerful technique for the installation of novel chemical functional groups in proteins. This is often achieved by recoding a stop codon and requires two additional components: an evolved aminoacyl tRNA synthetase (AARS) and a cognate tRNA. Analysis of the most successful AARSs reveals common characteristics. The highest fidelity NAA systems derived from the Methanocaldococcus jannaschii tyrosyl AARS feature specific mutations to two residues reported to interact with the hydroxyl group of the substrate tyrosine. We demonstrate that the restoration of just one of these determinants for amino acid specificity results in the loss of fidelity as the evolved AARSs become noticeably promiscuous. These results offer a partial explanation of a recently retracted strategy for the synthesis of glycoproteins. Similarly, we reinvestigated a tryptophanyl AARS reported to allow the site-selective incorporation of 5-hydroxy tryptophan within mammalian cells. In multiple experiments, the enzyme displayed elements of promiscuity despite its previous characterization as a high fidelity enzyme. Given the many similarities of the TyrRSs and TrpRSs reevaluated here, our findings can be largely combined, and in doing so they reinforce the long-established central dogma regarding the molecular basis by which these enzymes contribute to the fidelity of translation. Thus, our view is that the central claims of fidelity reported in several NAA systems remain unproven and unprecedented.

  13. Importance of single molecular determinants in the fidelity of expanded genetic codes

    PubMed Central

    Antonczak, Alicja K.; Simova, Zuzana; Yonemoto, Isaac T.; Bochtler, Matthias; Piasecka, Anna; Czapińska, Honorata; Brancale, Andrea; Tippmann, Eric M.

    2011-01-01

    The site-selective encoding of noncanonical amino acids (NAAs) is a powerful technique for the installation of novel chemical functional groups in proteins. This is often achieved by recoding a stop codon and requires two additional components: an evolved aminoacyl tRNA synthetase (AARS) and a cognate tRNA. Analysis of the most successful AARSs reveals common characteristics. The highest fidelity NAA systems derived from the Methanocaldococcus jannaschii tyrosyl AARS feature specific mutations to two residues reported to interact with the hydroxyl group of the substrate tyrosine. We demonstrate that the restoration of just one of these determinants for amino acid specificity results in the loss of fidelity as the evolved AARSs become noticeably promiscuous. These results offer a partial explanation of a recently retracted strategy for the synthesis of glycoproteins. Similarly, we reinvestigated a tryptophanyl AARS reported to allow the site-selective incorporation of 5-hydroxy tryptophan within mammalian cells. In multiple experiments, the enzyme displayed elements of promiscuity despite its previous characterization as a high fidelity enzyme. Given the many similarities of the TyrRSs and TrpRSs reevaluated here, our findings can be largely combined, and in doing so they reinforce the long-established central dogma regarding the molecular basis by which these enzymes contribute to the fidelity of translation. Thus, our view is that the central claims of fidelity reported in several NAA systems remain unproven and unprecedented. PMID:21224416

  14. System identification of the JPL micro-precision interferometer truss - Test-analysis reconciliation

    NASA Technical Reports Server (NTRS)

    Red-Horse, J. R.; Marek, E. L.; Levine-West, M.

    1993-01-01

    The JPL Micro-Precision Interferometer (MPI) is a testbed for studying the use of control-structure interaction technology in the design of space-based interferometers. A layered control architecture will be employed to regulate the interferometer optical system to tolerances in the nanometer range. An important aspect of designing and implementing the control schemes for such a system is the need for high fidelity, test-verified analytical structural models. This paper focuses on one aspect of the effort to produce such a model for the MPI structure, test-analysis model reconciliation. Pretest analysis, modal testing, and model refinement results are summarized for a series of tests at both the component and full system levels.

  15. Antibunched emission of photon pairs via quantum Zeno blockade.

    PubMed

    Huang, Yu-Ping; Kumar, Prem

    2012-01-20

    We propose a new methodology, namely, the "quantum Zeno blockade," for managing light scattering at a few-photon level in general nonlinear-optical media, such as crystals, fibers, silicon microrings, and atomic vapors. Using this tool, antibunched emission of photon pairs can be achieved, leading to potent quantum-optics applications such as deterministic entanglement generation without the need for heralding. In a practical implementation using an on-chip toroidal microcavity immersed in rubidium vapor, we estimate that high-fidelity entangled photons can be produced on-demand at MHz rates or higher, corresponding to an improvement of ≳10(7) times from the state-of-the-art. © 2012 American Physical Society

  16. National suicide rates a century after Durkheim: do we know enough to estimate error?

    PubMed

    Claassen, Cynthia A; Yip, Paul S; Corcoran, Paul; Bossarte, Robert M; Lawrence, Bruce A; Currier, Glenn W

    2010-06-01

    Durkheim's nineteenth-century analysis of national suicide rates dismissed prior concerns about mortality data fidelity. Over the intervening century, however, evidence documenting various types of error in suicide data has only mounted, and surprising levels of such error continue to be routinely uncovered. Yet the annual suicide rate remains the most widely used population-level suicide metric today. After reviewing the unique sources of bias incurred during stages of suicide data collection and concatenation, we propose a model designed to uniformly estimate error in future studies. A standardized method of error estimation uniformly applied to mortality data could produce data capable of promoting high quality analyses of cross-national research questions.

  17. Mapping GRACE Accelerometer Error

    NASA Astrophysics Data System (ADS)

    Sakumura, C.; Harvey, N.; McCullough, C. M.; Bandikova, T.; Kruizinga, G. L. H.

    2017-12-01

    After more than fifteen years in orbit, instrument noise, and accelerometer noise in particular, remains one of the limiting error sources for the NASA/DLR Gravity Recovery and Climate Experiment mission. The recent V03 Level-1 reprocessing campaign used a Kalman filter approach to produce a high fidelity, smooth attitude solution fusing star camera and angular acceleration data. This process provided an unprecedented method for analysis and error estimation of each instrument. The accelerometer exhibited signal aliasing, differential scale factors between electrode plates, and magnetic effects. By applying the noise model developed for the angular acceleration data to the linear measurements, we explore the magnitude and geophysical pattern of gravity field error due to the electrostatic accelerometer.

  18. Inside the Black Box: Examining Mediators and Moderators of a Middle School Science Intervention

    ERIC Educational Resources Information Center

    Desimone, Laura M.; Hill, Kirsten Lee

    2017-01-01

    We use data from a randomized controlled trial of a middle school science intervention to explore the causal mechanisms by which the intervention produced previously documented gains in student achievement. Our study finds that implementation fidelity, operationalized as a measure of the frequency of implementation of the cognitive science…

  19. Experiential Fidelity: Leveraging the Mind to Improve the VR Experience

    NASA Astrophysics Data System (ADS)

    Beckhaus, Steffi; Lindeman, Robert W.

    Much of Virtual Reality (VR) is about creating environments that are believable. But though the visual and audio experiences we provide today are already of a rather high sensory fidelity, there is still something lacking; something hinders us from fully buying into the worlds we experience through VR technology. We introduce the notion of Experiential Fidelity, which is an attempt to create a deeper sense of presence by carefully designing the user experience. We suggest to guide the users' frame of mind in a way that their expectations, attitude, and attention are aligned with the actual VR experience, and that the user's own imagination is stimulated to complete the experience. This work was inspired by a collection of personal magic moments and factors that were named by leading researchers in VR. We present those magic moments and some thoughts on how we can tap into experiential fidelity. We propose to do this not through technological means, but rather through the careful use of suggestion and allusion. By priming the user's mind prior to exposure to our virtual worlds, we can assist her in entering a mental state that is more willing to believe, even using the limited actual fidelity available today.

  20. Information theoretic approach for assessing image fidelity in photon-counting arrays.

    PubMed

    Narravula, Srikanth R; Hayat, Majeed M; Javidi, Bahram

    2010-02-01

    The method of photon-counting integral imaging has been introduced recently for three-dimensional object sensing, visualization, recognition and classification of scenes under photon-starved conditions. This paper presents an information-theoretic model for the photon-counting imaging (PCI) method, thereby providing a rigorous foundation for the merits of PCI in terms of image fidelity. This, in turn, can facilitate our understanding of the demonstrated success of photon-counting integral imaging in compressive imaging and classification. The mutual information between the source and photon-counted images is derived in a Markov random field setting and normalized by the source-image's entropy, yielding a fidelity metric that is between zero and unity, which respectively corresponds to complete loss of information and full preservation of information. Calculations suggest that the PCI fidelity metric increases with spatial correlation in source image, from which we infer that the PCI method is particularly effective for source images with high spatial correlation; the metric also increases with the reduction in photon-number uncertainty. As an application to the theory, an image-classification problem is considered showing a congruous relationship between the fidelity metric and classifier's performance.

  1. Information Processing, Specificity of Practice, and the Transfer of Learning: Considerations for Reconsidering Fidelity

    ERIC Educational Resources Information Center

    Grierson, Lawrence E. M.

    2014-01-01

    Much has been made in the recent medical education literature of the incorrect characterization of simulation along a continuum of low to high fidelity (Cook et al. "JAMA" 306(9): 978-988, 2011; Norman et al. "Med Educ" 46(7): 636-647, 2012; Teteris et al. "Adv Health Sci Educ" 17(1): 137-144, 2012). For the most…

  2. Acquisition, Retention, and Retraining: Effects of High and Low Fidelity in Training Devices. Technical Report 69-1.

    ERIC Educational Resources Information Center

    Grimsley, Douglas L.

    This study is the first in a series which was conducted under the name STRANGER III, and which was to examine trainee's long-term memory of motor skills. This phase examined the effects of varying fidelity of training devices on acquisition, retention, and reinstatement of ability to perform a 92-step procedural task. Three versions of the Section…

  3. A daylong clinical laboratory: from gaming to high-fidelity simulators.

    PubMed

    Bantz, Diana; Dancer, Michelle Mattice; Hodson-Carlton, Kay; Van Hove, Sharon

    2007-01-01

    Meeting required objectives in the clinical setting can be difficult because of low exposure to critical events. This has been further compounded by an increase in the number of enrolling students without a reciprocal rise in the number of field-related clinical sites. As simulation gains popularity in nursing, exploration of its use and benefits to teach nursing-related concepts is desirable. The authors discuss a variety of teaching strategies ranging from the use of games to high-fidelity simulators that have been incorporated into an all-day clinical simulation campus laboratory.

  4. Dshell++: A Component Based, Reusable Space System Simulation Framework

    NASA Technical Reports Server (NTRS)

    Lim, Christopher S.; Jain, Abhinandan

    2009-01-01

    This paper describes the multi-mission Dshell++ simulation framework for high fidelity, physics-based simulation of spacecraft, robotic manipulation and mobility systems. Dshell++ is a C++/Python library which uses modern script driven object-oriented techniques to allow component reuse and a dynamic run-time interface for complex, high-fidelity simulation of spacecraft and robotic systems. The goal of the Dshell++ architecture is to manage the inherent complexity of physicsbased simulations while supporting component model reuse across missions. The framework provides several features that support a large degree of simulation configurability and usability.

  5. Ablator Response Model Development: From Flight Data Back to Fundamental Experiments

    NASA Technical Reports Server (NTRS)

    Mansour, Nagi N.; Lachaud, Jean R.

    2013-01-01

    The successful Mars atmospheric entry by the Mars Science Laboratory (MSL-Curiosity) combined with the success of the Earth atmospheric entry by the Stardust capsule have established PICA as a major Thermal Protection Systems (TPS) material. We expect that this class of materials will be on the short list selected by NASA for any atmospheric entry missions and that it will be the lead of that list of materials in any planning, feasibility studies or flight readiness studies. In addition to NASAs successes, the Dragon capsule, the successful commercial space vehicle built by SpaceX, uses PICA-X, while the European Space Agency is considering ASTERM for its exploration missions that involve atmospheric entries, both of these materials are of the same family as PICA. In the talk, a high-fidelity model will be detailed and discussed. The model tracks the chemical composition of the gases produced during pyrolysis. As in the conventional models, it uses equilibrium chemistry to determine the recession rate at high temperatures but switches to in-volume finite-rate ablation for lower temperatures. It also tracks the time evolution of the porosity of the material. Progress in implementing this high-fidelity model in a code will be presented. In addition, a set of basic experimental data being supported for model validation will be summarized. The validation process for the model development will be discussed. Preliminary results will be presented for a case where detailed pyrolysis product chemistry is computed. Finally, a wish list for a set of validation experiments will be outlined and discussed.

  6. Silica-on-silicon waveguide quantum circuits.

    PubMed

    Politi, Alberto; Cryan, Martin J; Rarity, John G; Yu, Siyuan; O'Brien, Jeremy L

    2008-05-02

    Quantum technologies based on photons will likely require an integrated optics architecture for improved performance, miniaturization, and scalability. We demonstrate high-fidelity silica-on-silicon integrated optical realizations of key quantum photonic circuits, including two-photon quantum interference with a visibility of 94.8 +/- 0.5%; a controlled-NOT gate with an average logical basis fidelity of 94.3 +/- 0.2%; and a path-entangled state of two photons with fidelity of >92%. These results show that it is possible to directly "write" sophisticated photonic quantum circuits onto a silicon chip, which will be of benefit to future quantum technologies based on photons, including information processing, communication, metrology, and lithography, as well as the fundamental science of quantum optics.

  7. A Comparative Study of High and Low Fidelity Fan Models for Turbofan Engine System Simulation

    NASA Technical Reports Server (NTRS)

    Reed, John A.; Afjeh, Abdollah A.

    1991-01-01

    In this paper, a heterogeneous propulsion system simulation method is presented. The method is based on the formulation of a cycle model of a gas turbine engine. The model includes the nonlinear characteristics of the engine components via use of empirical data. The potential to simulate the entire engine operation on a computer without the aid of data is demonstrated by numerically generating "performance maps" for a fan component using two flow models of varying fidelity. The suitability of the fan models were evaluated by comparing the computed performance with experimental data. A discussion of the potential benefits and/or difficulties in connecting simulations solutions of differing fidelity is given.

  8. Heterogeneous oxygen availability affects the titer and topology but not the fidelity of plasmid DNA produced by Escherichia coli.

    PubMed

    Jaén, Karim E; Sigala, Juan-Carlos; Olivares-Hernández, Roberto; Niehaus, Karsten; Lara, Alvaro R

    2017-07-04

    Dissolved oxygen tension (DOT) is hardly constant and homogenously distributed in a bioreactor, which can have a negative impact in the metabolism and product synthesis. However, the effects of DOT on plasmid DNA (pDNA) production and quality have not been thoroughly investigated. In the present study, the effects of aerobic (DOT ≥30% air sat.), microaerobic (constant DOT = 3% air sat.) and oscillatory DOT (from 0 to 100% air sat.) conditions on pDNA production, quality and host performance were characterized. Microaerobic conditions had little effect on pDNA production, supercoiled fraction and sequence fidelity. By contrast, oscillatory DOT caused a 22% decrease in pDNA production compared with aerobic cultures. Although in aerobic cultures the pDNA supercoiled fraction was 98%, it decreased to 80% under heterogeneous DOT conditions. The different oxygen availabilities had no effect on the fidelity of the produced pDNA. The estimated metabolic fluxes indicated substantial differences at the level of the pentose phosphate pathway and TCA cycle under different conditions. Cyclic changes in fermentative pathway fluxes, as well as fast shifts in the fluxes through cytochromes, were also estimated. Model-based genetic modifications that can potentially improve the process performance are suggested. DOT heterogeneities strongly affected cell performance, pDNA production and topology. This should be considered when operating or scaling-up a bioreactor with deficient mixing. Constant microaerobic conditions affected the bacterial metabolism but not the amount or quality of pDNA. Therefore, pDNA production in microaerobic cultures may be an alternative for bioreactor operation at higher oxygen transfer rates.

  9. High-Fidelity Modelng and Simulation for a High Flux Isotope Reactor Low-Enriched Uranium Core Design

    DOE PAGES

    Betzler, Benjamin R.; Chandler, David; Davidson, Eva E.; ...

    2017-05-08

    A high-fidelity model of the High Flux Isotope Reactor (HFIR) with a low-enriched uranium (LEU) fuel design and a representative experiment loading has been developed to serve as a new reference model for LEU conversion studies. With the exception of the fuel elements, this HFIR LEU model is completely consistent with the current highly enriched uranium HFIR model. Results obtained with the new LEU model provide a baseline for analysis of alternate LEU fuel designs and further optimization studies. The newly developed HFIR LEU model has an explicit representation of the HFIR-specific involute fuel plate geometry, including the within-plate fuelmore » meat contouring, and a detailed geometry model of the fuel element side plates. Such high-fidelity models are necessary to accurately account for the self-shielding from 238U and the depletion of absorber materials present in the side plates. In addition, a method was developed to account for fuel swelling in the high-density LEU fuel plates during the depletion simulation. In conclusion, calculated time-dependent metrics for the HFIR LEU model include fission rate and cumulative fission density distributions, flux and reaction rates for relevant experiment locations, point kinetics data, and reactivity coefficients.« less

  10. High-Fidelity Modelng and Simulation for a High Flux Isotope Reactor Low-Enriched Uranium Core Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Betzler, Benjamin R.; Chandler, David; Davidson, Eva E.

    A high-fidelity model of the High Flux Isotope Reactor (HFIR) with a low-enriched uranium (LEU) fuel design and a representative experiment loading has been developed to serve as a new reference model for LEU conversion studies. With the exception of the fuel elements, this HFIR LEU model is completely consistent with the current highly enriched uranium HFIR model. Results obtained with the new LEU model provide a baseline for analysis of alternate LEU fuel designs and further optimization studies. The newly developed HFIR LEU model has an explicit representation of the HFIR-specific involute fuel plate geometry, including the within-plate fuelmore » meat contouring, and a detailed geometry model of the fuel element side plates. Such high-fidelity models are necessary to accurately account for the self-shielding from 238U and the depletion of absorber materials present in the side plates. In addition, a method was developed to account for fuel swelling in the high-density LEU fuel plates during the depletion simulation. In conclusion, calculated time-dependent metrics for the HFIR LEU model include fission rate and cumulative fission density distributions, flux and reaction rates for relevant experiment locations, point kinetics data, and reactivity coefficients.« less

  11. [Low Fidelity Simulation of a Zero-Y Robot

    NASA Technical Reports Server (NTRS)

    Sweet, Adam

    2001-01-01

    The item to be cleared is a low-fidelity software simulation model of a hypothetical freeflying robot designed for use in zero gravity environments. This simulation model works with the HCC simulation system that was developed by Xerox PARC and NASA Ames Research Center. HCC has been previously cleared for distribution. When used with the HCC software, the model computes the location and orientation of the simulated robot over time. Failures (such as a broken motor) can be injected into the simulation to produce simulated behavior corresponding to the failure. Release of this simulation will allow researchers to test their software diagnosis systems by attempting to diagnose the simulated failure from the simulated behavior. This model does not contain any encryption software nor can it perform any control tasks that might be export controlled.

  12. High-Fidelity Computational Aerodynamics of the Elytron 4S UAV

    NASA Technical Reports Server (NTRS)

    Ventura Diaz, Patricia; Yoon, Seokkwan; Theodore, Colin R.

    2018-01-01

    High-fidelity Computational Fluid Dynamics (CFD) have been carried out for the Elytron 4S Unmanned Aerial Vehicle (UAV), also known as the converticopter "proto12". It is the scaled wind tunnel model of the Elytron 4S, an Urban Air Mobility (UAM) concept, a tilt-wing, box-wing rotorcraft capable of Vertical Take-Off and Landing (VTOL). The three-dimensional unsteady Navier-Stokes equations are solved on overset grids employing high-order accurate schemes, dual-time stepping, and a hybrid turbulence model using NASA's CFD code OVERFLOW. The Elytron 4S UAV has been simulated in airplane mode and in helicopter mode.

  13. Illness Management & Recovery (IMR) in the Netherlands; a naturalistic pilot study to explore the feasibility of a randomized controlled trial.

    PubMed

    Roosenschoon, Bert-Jan; van Weeghel, Jaap; Bogaards, Moniek; Deen, Mathijs L; Mulder, Cornelis L

    2016-11-09

    Illness Management & Recovery (IMR) is a curriculum-based program for people with severe and persistent mental illness. To date, four randomized controlled trials (RCTs) have been published on it. As these produced mixed results, we conducted a pilot study to test the feasibility of conducting a new RCT in a Dutch psychiatric institute. Because our primary objective was to evaluate support for implementing IMR on a broader scale, we examined participant recruitment, client outcomes, and clients' and clinicians' satisfaction. Secondary objectives were to evaluate fidelity, trainers' training and supervision, and to explore program duration, dropout, and client characteristics related to dropout. For reporting, we used the checklist for pilot studies adopted from the CONSORT Statement. This program evaluation included a process-evaluation and an outcome evaluation with a One Group Pre-Posttest Design (N = 81). Interviews and internal reports were used to monitor participant numbers, program duration, dropout, and completers' characteristics. Clients' and clinicians' satisfaction and provision of trainers' training and supervision were assessed through interviews. Fidelity was assessed on the IMR Fidelity Scale; client outcomes were assessed on the IMR scale (client and clinician versions) and the Recovery Markers Questionnaire (RMQ). Eighty-one participants were recruited of 167 people who were assessed for eligibility. Completers and clinicians were satisfied, and scores for completers improved significantly on the IMR scale (clinician version) (d = 0.84) and RMQ (d = 0.52), and not significantly on the IMR scale client version (d = 0.41). Mean fidelity was good, but three groups had only moderate fidelity. Our feasibility criterion for trainers' education and supervision was partly attained. Dropout from treatment was 51 %; female participants and people who scored higher on both IMR-scales at baseline had a significantly lower chance of dropping out. The duration of IMR varied (M = 12.7 months, SD = 2.87). Results suggested that feasibility of conducting an RCT on IMR was good. Special attention is required to fidelity, IMR duration, trainers' education and supervision, and dropout, especially of men. One study limitation was our inability to conduct follow-up measurements of non-completers.

  14. Optimized pulses for the control of uncertain qubits

    DOE PAGES

    Grace, Matthew D.; Dominy, Jason M.; Witzel, Wayne M.; ...

    2012-05-18

    The construction of high-fidelity control fields that are robust to control, system, and/or surrounding environment uncertainties is a crucial objective for quantum information processing. Using the two-state Landau-Zener model for illustrative simulations of a controlled qubit, we generate optimal controls for π/2 and π pulses and investigate their inherent robustness to uncertainty in the magnitude of the drift Hamiltonian. Next, we construct a quantum-control protocol to improve system-drift robustness by combining environment-decoupling pulse criteria and optimal control theory for unitary operations. By perturbatively expanding the unitary time-evolution operator for an open quantum system, previous analysis of environment-decoupling control pulses hasmore » calculated explicit control-field criteria to suppress environment-induced errors up to (but not including) third order from π/2 and π pulses. We systematically integrate this criteria with optimal control theory, incorporating an estimate of the uncertain parameter to produce improvements in gate fidelity and robustness, demonstrated via a numerical example based on double quantum dot qubits. For the qubit model used in this work, postfacto analysis of the resulting controls suggests that realistic control-field fluctuations and noise may contribute just as significantly to gate errors as system and environment fluctuations.« less

  15. Fast Longwave and Shortwave Radiative Flux (FLASHFlux) Products from CERES and MODIS Measurements

    NASA Technical Reports Server (NTRS)

    Stackhouse, Paul W., Jr.; Kratz, David P.; McGarragh, Greg R.; Gupta, Shashi K.; Geier, Erika B.

    2006-01-01

    The Clouds and the Earth s Radiant Energy Systems (CERES) project is currently producing world-class climatological data products derived from measurements taken aboard the Terra and Aqua spacecrafts (Wielicki et al., 1996). While of exceptional fidelity, these data products require a considerable amount of processing to assure quality and verify accuracy and precision. Obtaining such high quality assurance, however, means that the CERES data is typically released more than six months after the acquisition of the initial measurements. For climate studies, such delays are of little consequence, especially considering the improved quality of the released data products. There are, however, many uses for the CERES data products on a near real-time basis. These include: CERES instrument calibration and subsystem quality checks, CLOUDSAT operations, seasonal predictions, agricultural and ocean assimilations, support of field campaigns, and outreach programs such as S'Cool. The FLASHflux project was envisioned as a conduit whereby CERES data could be provided to the community within a week of the initial measurements, with the trade-off that some degree of fidelity would be exacted to gain speed. In this paper, we will report on some very encouraging initial results from the FLASHflux project in which we compared the FLASHflux instantaneous surface fluxes to the CERES surface-only flux algorithm data products.

  16. Selection of UV Resins for Nanostructured Molds for Thermal-NIL.

    PubMed

    Jia, Zheng; Choi, Junseo; Park, Sunggook

    2018-06-18

    Nanoimprint molds made of soft polymeric materials have advantages of low demolding force and low fabrication cost over Si or metal-based hard molds. However, such advantages are often sacrificed by their reduced replication fidelity associated with the low mechanical strength. In this paper, we studied replication fidelity of different UV-resin molds copied from a Si master mold via UV nanoimprint lithography (NIL) and their thermal imprinting performance into a thermoplastic polymer. Four different UV resins were studied: two were high surface energy UV resins based on tripropyleneglycol diacrylate (TPGDA resin) and polypropyleneglycol diacrylate (PPGDA resin), and the other two were commercially available, low surface energy poly-urethane acrylate (PUA resin) and fluorine-containing (MD 700) UV resins. The replication fidelity among the four UV-resins during UV nanoimprint lithograph from a Si master with sharp nanostructures was in the increasing order of (poorest) PUA resin < MD 700 < PPGDA resin < TPGDA resin (best). The results show that the high surface energy and small monomer size are keys to achieving good UV resin filling into sharp nanostructures over the viscosity of the resin solution. When the four UV-resin molds were used for thermal-NIL into a thermoplastic polymer, the replication fidelity was in the increasing order of (poorest) MD 700 < TPGDA resin < PUA resin (best), which follows the same order of their Young's moduli. Our results indicate that the selection of an appropriate UV resin for NIL molds requires consideration of the replication fidelities in the mold fabrication and the subsequent thermal-NIL into thermoplastic polymers. © 2018 IOP Publishing Ltd.

  17. Implementation of integrated dual disorders treatment: a qualitative analysis of facilitators and barriers.

    PubMed

    Brunette, Mary F; Asher, Dianne; Whitley, Rob; Lutz, Wilma J; Wieder, Barbara L; Jones, Amanda M; McHugo, Gregory J

    2008-09-01

    Approximately half of the people who have serious mental illnesses experience a co-occurring substance use disorder at some point in their lifetime. Integrated dual disorders treatment, a program to treat persons with co-occurring disorders, improves outcomes but is not widely available in public mental health settings. This report describes the extent to which this intervention was implemented by 11 community mental health centers participating in a large study of practice implementation. Facilitators and barriers to implementation are described. Trained implementation monitors conducted regular site visits over two years. During visits, monitors interviewed key informants, conducted ethnographic observations of implementation efforts, and assessed fidelity to the practice model. These data were coded and used as a basis for detailed site reports summarizing implementation processes. The authors reviewed the reports and distilled the three top facilitators and barriers for each site. The most prominent cross-site facilitators and barriers were identified. Two sites reached high fidelity, six sites reached moderate fidelity, and three sites remained at low fidelity over the two years. Prominent facilitators and barriers to implementation with moderate to high fidelity were administrative leadership, consultation and training, supervisor mastery and supervision, chronic staff turnover, and finances. Common facilitators and barriers to implementation of integrated dual disorders treatment emerged across sites. The results confirmed the importance of the use of the consultant-trainer in the model of implementation, as well as the need for intensive activities at multiple levels to facilitate implementation. Further research on service implementation is needed, including but not limited to clarifying strategies to overcome barriers.

  18. The Impact of Implementation Fidelity on Mortality Under a CD4-Stratified Timing Strategy for Antiretroviral Therapy in Patients With Tuberculosis.

    PubMed

    Patel, Monita R; Westreich, Daniel; Yotebieng, Marcel; Nana, Mbonze; Eron, Joseph J; Behets, Frieda; Van Rie, Annelies

    2015-05-01

    Among patients with tuberculosis and human immunodeficiency virus type 1, CD4-stratified initiation of antiretroviral therapy (ART) is recommended, with earlier ART in those with low CD4 counts. However, the impact of implementation fidelity to this recommendation is unknown. We examined a prospective cohort study of 395 adult patients diagnosed with tuberculosis and human immunodeficiency virus between August 2007 and November 2009 in Kinshasa, Democratic Republic of the Congo. ART was to be initiated after 1 month of tuberculosis treatment at a CD4 count of <100 cells/mm(3) or World Health Organization stage 4 (other than extrapulmonary tuberculosis) and after 2 months of tuberculosis treatment at a CD4 count of 100-350 cells/mm(3). We used the parametric g-formula to estimate the impact of implementation fidelity on 6-month mortality. Observed implementation fidelity was low (46%); 54% of patients either experienced delays in ART initiation or did not initiate ART, which could be avoided under perfect implementation fidelity. The observed mortality risk was 12.0% (95% confidence interval (CI): 8.2, 15.7); under complete (counterfactual) implementation fidelity, the mortality risk was 7.8% (95% CI: 2.4, 12.3), corresponding to a risk reduction of 4.2% (95% CI: 0.3, 8.1) and a preventable fraction of 35.1% (95% CI: 2.9, 67.9). Strategies to achieve high implementation fidelity to CD4-stratified ART timing are needed to maximize survival benefit. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. The Application of High Energy Resolution Green's Functions to Threat Scenario Simulation

    NASA Astrophysics Data System (ADS)

    Thoreson, Gregory G.; Schneider, Erich A.

    2012-04-01

    Radiation detectors installed at key interdiction points provide defense against nuclear smuggling attempts by scanning vehicles and traffic for illicit nuclear material. These hypothetical threat scenarios may be modeled using radiation transport simulations. However, high-fidelity models are computationally intensive. Furthermore, the range of smuggler attributes and detector technologies create a large problem space not easily overcome by brute-force methods. Previous research has demonstrated that decomposing the scenario into independently simulated components using Green's functions can simulate photon detector signals with coarse energy resolution. This paper extends this methodology by presenting physics enhancements and numerical treatments which allow for an arbitrary level of energy resolution for photon transport. As a result, spectroscopic detector signals produced from full forward transport simulations can be replicated while requiring multiple orders of magnitude less computation time.

  20. From concept to content: assessing the implementation fidelity of a chronic care model for frail, older people who live at home.

    PubMed

    Muntinga, Maaike E; Van Leeuwen, Karen M; Schellevis, François G; Nijpels, Giel; Jansen, Aaltje P D

    2015-01-22

    Implementation fidelity, the degree to which a care program is implemented as intended, can influence program impact. Since results of trials that aim to implement comprehensive care programs for frail, older people have been conflicting, assessing implementation fidelity alongside these trials is essential to differentiate between flaws inherent to the program and implementation issues. This study demonstrates how a theory-based assessment of fidelity can increase insight in the implementation process of a complex intervention in primary elderly care. The Geriatric Care Model was implemented among 35 primary care practices in the Netherlands. During home visits, practice nurses conducted a comprehensive geriatric assessment and wrote a tailored care plan. Multidisciplinary team consultations were organized with the aim to enhance the coordination between professionals caring for a single patient with complex needs. To assess fidelity, we identified 5 key intervention components and formulated corresponding research questions using Carroll's framework for fidelity. Adherence (coverage, frequency, duration, content) was assessed per intervention component during and at the end of the intervention period. Two moderating factors (participant responsiveness and facilitation strategies) were assessed at the end of the intervention. Adherence to the geriatric assessments and care plans was high, but decreased over time. Adherence to multidisciplinary consultations was initially poor, but increased over time. We found that individual differences in adherence between practice nurses and primary care physicians were moderate, while differences in participant responsiveness (satisfaction, involvement) were more distinct. Nurses deviated from protocol due to contextual factors and personal work routines. Adherence to the Geriatric Care Model was high for most of the essential intervention components. Study limitations include the limited number of assessed moderating factors. We argue that a longitudinal investigation of adherence per intervention component is essential for a complete understanding of the implementation process, but that such investigations may be complicated by practical and methodological challenges. The Netherlands National Trial Register (NTR). 2160 .

  1. An intelligent tutoring system for the investigation of high performance skill acquisition

    NASA Technical Reports Server (NTRS)

    Fink, Pamela K.; Herren, L. Tandy; Regian, J. Wesley

    1991-01-01

    The issue of training high performance skills is of increasing concern. These skills include tasks such as driving a car, playing the piano, and flying an aircraft. Traditionally, the training of high performance skills has been accomplished through the use of expensive, high-fidelity, 3-D simulators, and/or on-the-job training using the actual equipment. Such an approach to training is quite expensive. The design, implementation, and deployment of an intelligent tutoring system developed for the purpose of studying the effectiveness of skill acquisition using lower-cost, lower-physical-fidelity, 2-D simulation. Preliminary experimental results are quite encouraging, indicating that intelligent tutoring systems are a cost-effective means of training high performance skills.

  2. gr-MRI: A software package for magnetic resonance imaging using software defined radios.

    PubMed

    Hasselwander, Christopher J; Cao, Zhipeng; Grissom, William A

    2016-09-01

    The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately $2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR's ability to generate frequency-swept RF waveforms was validated and compared to the scanner's commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs. Copyright © 2016. Published by Elsevier Inc.

  3. Multi-fidelity Gaussian process regression for prediction of random fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parussini, L.; Venturi, D., E-mail: venturi@ucsc.edu; Perdikaris, P.

    We propose a new multi-fidelity Gaussian process regression (GPR) approach for prediction of random fields based on observations of surrogate models or hierarchies of surrogate models. Our method builds upon recent work on recursive Bayesian techniques, in particular recursive co-kriging, and extends it to vector-valued fields and various types of covariances, including separable and non-separable ones. The framework we propose is general and can be used to perform uncertainty propagation and quantification in model-based simulations, multi-fidelity data fusion, and surrogate-based optimization. We demonstrate the effectiveness of the proposed recursive GPR techniques through various examples. Specifically, we study the stochastic Burgersmore » equation and the stochastic Oberbeck–Boussinesq equations describing natural convection within a square enclosure. In both cases we find that the standard deviation of the Gaussian predictors as well as the absolute errors relative to benchmark stochastic solutions are very small, suggesting that the proposed multi-fidelity GPR approaches can yield highly accurate results.« less

  4. The relationship between school-level characteristics and implementation fidelity of a coordinated school health childhood obesity prevention intervention.

    PubMed

    Lederer, Alyssa M; King, Mindy H; Sovinski, Danielle; Seo, Dong-Chul; Kim, Nayoung

    2015-01-01

    Curtailing childhood obesity is a public health imperative. Although multicomponent school-based programs reduce obesity among children, less is known about the implementation fidelity of these interventions. This study examines process evaluation findings for the Healthy, Energetic Ready, Outstanding, Enthusiastic, Schools (HEROES) Initiative, a tri-state school-based childhood obesity prevention intervention based on the coordinated school health (CSH) model. Site visits were conducted that included key stakeholder interviews, observation, and document review. Scores were given for 8 domains, and a total implementation score was calculated. Two-way analyses of variance were conducted to examine the relationship of 4 school-level characteristics: elementary vs. middle/high schools, public vs. private schools, district vs. building level implementation, and socioeconomic status on each implementation area. Overall, schools had high fidelity scores, although some domains were implemented more successfully than others. Three school-level characteristics were associated with 1 or more domains, with elementary schools and schools implementing at the building level consistently having higher implementation scores than their counterparts. Process evaluation findings provide insight into successes and challenges schools implementing the CSH approach may encounter. Although preliminary, these findings on school-level characteristics establish a new area of research related to school-based childhood obesity prevention programs' implementation fidelity. © 2014, American School Health Association.

  5. Development and Implementation: B’More Healthy Communities for Kid’s Store and Wholesaler Intervention

    PubMed Central

    Schwendler, Teresa; Shipley, Cara; Budd, Nadine; Trude, Angela; Surkan, Pamela J.; Steeves, Elizabeth Anderson; de Morais Sato, Priscila; Eckmann, Thomas; Loh, Hong; Gittelsohn, Joel

    2017-01-01

    Higher rates of obesity and obesity-related chronic disease are prevalent in communities where there is limited access to affordable, healthy food. The B’More Healthy Communities for Kids (BHCK) trial worked at multiple levels of the food environment including food wholesalers and corner stores to improve the surrounding community’s access to healthy food. The objective of this article is to describe the development and implementation of BHCK’s corner store and wholesaler interventions through formal process evaluation. Researchers evaluated each level of the intervention to assess reach, dose delivered, and fidelity. Corner store and wholesaler reach, dose delivered, and fidelity were measured by number of interactions, promotional materials distributed, and maintenance of study materials, respectively. Overall, the corner store implementation showed moderate reach, dose delivered, and high fidelity. The wholesaler intervention was implemented with high reach, dose, and fidelity. The program held 355 corner store interactive sessions and had 9,347 community member interactions, 21% of which were with children between the ages of 10 and 14 years. There was a 15% increase in corner store promoted food stocking during Wave 1 and a 17% increase during Wave 2. These findings demonstrate a successfully implemented food retailer intervention in a low-income urban setting. PMID:28343413

  6. Becoming a high-fidelity - super - imitator: what are the contributions of social and individual learning?

    PubMed

    Subiaul, Francys; Patterson, Eric M; Schilder, Brian; Renner, Elizabeth; Barr, Rachel

    2015-11-01

    In contrast to other primates, human children's imitation performance goes from low to high fidelity soon after infancy. Are such changes associated with the development of other forms of learning? We addressed this question by testing 215 children (26-59 months) on two social conditions (imitation, emulation) - involving a demonstration - and two asocial conditions (trial-and-error, recall) - involving individual learning - using two touchscreen tasks. The tasks required responding to either three different pictures in a specific picture order (Cognitive: Airplane→Ball→Cow) or three identical pictures in a specific spatial order (Motor-Spatial: Up→Down→Right). There were age-related improvements across all conditions and imitation, emulation and recall performance were significantly better than trial-and-error learning. Generalized linear models demonstrated that motor-spatial imitation fidelity was associated with age and motor-spatial emulation performance, but cognitive imitation fidelity was only associated with age. While this study provides evidence for multiple imitation mechanisms, the development of one of those mechanisms - motor-spatial imitation - may be bootstrapped by the development of another social learning skill - motor-spatial emulation. Together, these findings provide important clues about the development of imitation, which is arguably a distinctive feature of the human species. © 2014 John Wiley & Sons Ltd.

  7. HIGH-FIDELITY SIMULATION-DRIVEN MODEL DEVELOPMENT FOR COARSE-GRAINED COMPUTATIONAL FLUID DYNAMICS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanna, Botros N.; Dinh, Nam T.; Bolotnov, Igor A.

    Nuclear reactor safety analysis requires identifying various credible accident scenarios and determining their consequences. For a full-scale nuclear power plant system behavior, it is impossible to obtain sufficient experimental data for a broad range of risk-significant accident scenarios. In single-phase flow convective problems, Direct Numerical Simulation (DNS) and Large Eddy Simulation (LES) can provide us with high fidelity results when physical data are unavailable. However, these methods are computationally expensive and cannot be afforded for simulation of long transient scenarios in nuclear accidents despite extraordinary advances in high performance scientific computing over the past decades. The major issue is themore » inability to make the transient computation parallel, thus making number of time steps required in high-fidelity methods unaffordable for long transients. In this work, we propose to apply a high fidelity simulation-driven approach to model sub-grid scale (SGS) effect in Coarse Grained Computational Fluid Dynamics CG-CFD. This approach aims to develop a statistical surrogate model instead of the deterministic SGS model. We chose to start with a turbulent natural convection case with volumetric heating in a horizontal fluid layer with a rigid, insulated lower boundary and isothermal (cold) upper boundary. This scenario of unstable stratification is relevant to turbulent natural convection in a molten corium pool during a severe nuclear reactor accident, as well as in containment mixing and passive cooling. The presented approach demonstrates how to create a correction for the CG-CFD solution by modifying the energy balance equation. A global correction for the temperature equation proves to achieve a significant improvement to the prediction of steady state temperature distribution through the fluid layer.« less

  8. High-Fidelity Roadway Modeling and Simulation

    NASA Technical Reports Server (NTRS)

    Wang, Jie; Papelis, Yiannis; Shen, Yuzhong; Unal, Ozhan; Cetin, Mecit

    2010-01-01

    Roads are an essential feature in our daily lives. With the advances in computing technologies, 2D and 3D road models are employed in many applications, such as computer games and virtual environments. Traditional road models were generated by professional artists manually using modeling software tools such as Maya and 3ds Max. This approach requires both highly specialized and sophisticated skills and massive manual labor. Automatic road generation based on procedural modeling can create road models using specially designed computer algorithms or procedures, reducing the tedious manual editing needed for road modeling dramatically. But most existing procedural modeling methods for road generation put emphasis on the visual effects of the generated roads, not the geometrical and architectural fidelity. This limitation seriously restricts the applicability of the generated road models. To address this problem, this paper proposes a high-fidelity roadway generation method that takes into account road design principles practiced by civil engineering professionals, and as a result, the generated roads can support not only general applications such as games and simulations in which roads are used as 3D assets, but also demanding civil engineering applications, which requires accurate geometrical models of roads. The inputs to the proposed method include road specifications, civil engineering road design rules, terrain information, and surrounding environment. Then the proposed method generates in real time 3D roads that have both high visual and geometrical fidelities. This paper discusses in details the procedures that convert 2D roads specified in shape files into 3D roads and civil engineering road design principles. The proposed method can be used in many applications that have stringent requirements on high precision 3D models, such as driving simulations and road design prototyping. Preliminary results demonstrate the effectiveness of the proposed method.

  9. Effects of school-wide positive behavioral interventions and supports and fidelity of implementation on problem behavior in high schools.

    PubMed

    Flannery, K B; Fenning, P; Kato, M McGrath; McIntosh, K

    2014-06-01

    High school is an important time in the educational career of students. It is also a time when adolescents face many behavioral, academic, and social-emotional challenges. Current statistics about the behavioral, academic, and social-emotional challenges faced by adolescents, and the impact on society through incarceration and dropout, have prompted high schools to direct their attention toward keeping students engaged and reducing high-risk behavioral challenges. The purpose of the study was to examine the effects of School-Wide Positive Behavioral Interventions and Supports (SW-PBIS) on the levels of individual student problem behaviors during a 3-year effectiveness trial without random assignment to condition. Participants were 36,653 students in 12 high schools. Eight schools implemented SW-PBIS, and four schools served as comparison schools. Results of a multilevel latent growth model showed statistically significant decreases in student office discipline referrals in SW-PBIS schools, with increases in comparison schools, when controlling for enrollment and percent of students receiving free or reduced price meals. In addition, as fidelity of implementation increased, office discipline referrals significantly decreased. Results are discussed in terms of effectiveness of a SW-PBIS approach in high schools and considerations to enhance fidelity of implementation. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  10. Dynamic mode decomposition for plasma diagnostics and validation.

    PubMed

    Taylor, Roy; Kutz, J Nathan; Morgan, Kyle; Nelson, Brian A

    2018-05-01

    We demonstrate the application of the Dynamic Mode Decomposition (DMD) for the diagnostic analysis of the nonlinear dynamics of a magnetized plasma in resistive magnetohydrodynamics. The DMD method is an ideal spatio-temporal matrix decomposition that correlates spatial features of computational or experimental data while simultaneously associating the spatial activity with periodic temporal behavior. DMD can produce low-rank, reduced order surrogate models that can be used to reconstruct the state of the system with high fidelity. This allows for a reduction in the computational cost and, at the same time, accurate approximations of the problem, even if the data are sparsely sampled. We demonstrate the use of the method on both numerical and experimental data, showing that it is a successful mathematical architecture for characterizing the helicity injected torus with steady inductive (HIT-SI) magnetohydrodynamics. Importantly, the DMD produces interpretable, dominant mode structures, including a stationary mode consistent with our understanding of a HIT-SI spheromak accompanied by a pair of injector-driven modes. In combination, the 3-mode DMD model produces excellent dynamic reconstructions across the domain of analyzed data.

  11. Dynamic mode decomposition for plasma diagnostics and validation

    NASA Astrophysics Data System (ADS)

    Taylor, Roy; Kutz, J. Nathan; Morgan, Kyle; Nelson, Brian A.

    2018-05-01

    We demonstrate the application of the Dynamic Mode Decomposition (DMD) for the diagnostic analysis of the nonlinear dynamics of a magnetized plasma in resistive magnetohydrodynamics. The DMD method is an ideal spatio-temporal matrix decomposition that correlates spatial features of computational or experimental data while simultaneously associating the spatial activity with periodic temporal behavior. DMD can produce low-rank, reduced order surrogate models that can be used to reconstruct the state of the system with high fidelity. This allows for a reduction in the computational cost and, at the same time, accurate approximations of the problem, even if the data are sparsely sampled. We demonstrate the use of the method on both numerical and experimental data, showing that it is a successful mathematical architecture for characterizing the helicity injected torus with steady inductive (HIT-SI) magnetohydrodynamics. Importantly, the DMD produces interpretable, dominant mode structures, including a stationary mode consistent with our understanding of a HIT-SI spheromak accompanied by a pair of injector-driven modes. In combination, the 3-mode DMD model produces excellent dynamic reconstructions across the domain of analyzed data.

  12. The role of treatment fidelity on outcomes during a randomized field trial of an autism intervention

    PubMed Central

    Mandell, David S; Stahmer, Aubyn C; Shin, Sujie; Xie, Ming; Reisinger, Erica; Marcus, Steven C

    2013-01-01

    This randomized field trial comparing Strategies for Teaching based on Autism Research and Structured Teaching enrolled educators in 33 kindergarten-through-second-grade autism support classrooms and 119 students, aged 5–8 years in the School District of Philadelphia. Students were assessed at the beginning and end of the academic year using the Differential Ability Scales. Program fidelity was measured through video coding and use of a checklist. Outcomes were assessed using linear regression with random effects for classroom and student. Average fidelity was 57% in Strategies for Teaching based on Autism Research classrooms and 48% in Structured Teaching classrooms. There was a 9.2-point (standard deviation = 9.6) increase in Differential Ability Scales score over the 8-month study period, but no main effect of program. There was a significant interaction between fidelity and group. In classrooms with either low or high program fidelity, students in Strategies for Teaching based on Autism Research experienced a greater gain in Differential Ability Scales score than students in Structured Teaching (11.2 vs 5.5 points and 11.3 vs 8.9 points, respectively). In classrooms with moderate fidelity, students in Structured Teaching experienced a greater gain than students in Strategies for Teaching based on Autism Research (10.1 vs 4.4 points). The results suggest significant variability in implementation of evidence-based practices, even with supports, and also suggest the need to address challenging issues related to implementation measurement in community settings. PMID:23592849

  13. Magnetic Resonance Project 35-26-7: A Cuban Case of Engineering Physics and Biophysics

    NASA Astrophysics Data System (ADS)

    Cabal Mirabal, Carlos A.

    The Magnetic Resonance Project 35-26-7 started in December 1987, commissioned by the [then] Cuban Prime Minister, Fidel Castro, who—concerned about introducing technological advancement into the Cuban health [system]—had for some months taken an interest in the possibility of building magnetic resonance imaging (MRI) equipment for medical diagnosis in Cuba (Zito M, Argüelles MM et al, Y sin embargo-: ciencia: hablan 30 investigadores cubanos. Editoria April, Habana, pp 56-66, 1999; Cabal, Biofísica Médica. In: Fidel Castro Dìas-Balart (eds) Cuba. Amanecer del Tercer Milenio. Ciencia, Sociedad y Tecnología: Biofísica Médica. Debate Editorial, Madrid, pp 31-48, 2002). Many of the companies producing MRI equipment were unable to deliver this technology to Cuba due to the bloqueo, the United States embargo against Cuba. Those who were later to advance the project's progress in scientific technology initially regarded the implementation of such a project in a developing country as unfeasible due to its complexity. But Fidel's belief and confidence and in turn the Cuban scientists' commitment to him and to Cuban science proved to be an undeniable factors for its success.

  14. Distribution of quantum Fisher information in asymmetric cloning machines

    PubMed Central

    Xiao, Xing; Yao, Yao; Zhou, Lei-Ming; Wang, Xiaoguang

    2014-01-01

    An unknown quantum state cannot be copied and broadcast freely due to the no-cloning theorem. Approximate cloning schemes have been proposed to achieve the optimal cloning characterized by the maximal fidelity between the original and its copies. Here, from the perspective of quantum Fisher information (QFI), we investigate the distribution of QFI in asymmetric cloning machines which produce two nonidentical copies. As one might expect, improving the QFI of one copy results in decreasing the QFI of the other copy. It is perhaps also unsurprising that asymmetric phase-covariant cloning outperforms universal cloning in distributing QFI since a priori information of the input state has been utilized. However, interesting results appear when we compare the distributabilities of fidelity (which quantifies the full information of quantum states), and QFI (which only captures the information of relevant parameters) in asymmetric cloning machines. Unlike the results of fidelity, where the distributability of symmetric cloning is always optimal for any d-dimensional cloning, we find that any asymmetric cloning outperforms symmetric cloning on the distribution of QFI for d ≤ 18, whereas some but not all asymmetric cloning strategies could be worse than symmetric ones when d > 18. PMID:25484234

  15. Site fidelity, size, and morphology may differ by tidal position for an intertidal fish, Bathygobius cocosensis (Perciformes-Gobiidae), in Eastern Australia

    PubMed Central

    Malard, Lucie A.; McGuigan, Katrina

    2016-01-01

    The intertidal zone is a transitional environment that undergoes daily environmental fluctuations as tides rise and fall. Relatively few fish species are adapted to endure the physiological pressures of this environment. This study focused on Bathygobius cocosensis (Gobiidae), a common intertidal fish in New South Wales, Australia. We investigated whether shore height impacted site fidelity, survival probability, fish size, and morphological traits with respect to tidal height. Mark-recapture methods were used over a five month period to determine if individuals in high shore pools had greater site fidelity; fish in high tide pools were more than twice as likely to be recaptured in their original pool than fish from low tide pools. High pool individuals were, on average, smaller with larger eyes and longer snouts relative to their size as compared to low pool individuals. We discuss several mechanisms that could cause the observed pattern in morphological variation. Ultimately, this study suggests that within species behaviour and morphology differ by tidal position for an intertidal fish. PMID:27547568

  16. Site fidelity, size, and morphology may differ by tidal position for an intertidal fish, Bathygobius cocosensis (Perciformes-Gobiidae), in Eastern Australia.

    PubMed

    Malard, Lucie A; McGuigan, Katrina; Riginos, Cynthia

    2016-01-01

    The intertidal zone is a transitional environment that undergoes daily environmental fluctuations as tides rise and fall. Relatively few fish species are adapted to endure the physiological pressures of this environment. This study focused on Bathygobius cocosensis (Gobiidae), a common intertidal fish in New South Wales, Australia. We investigated whether shore height impacted site fidelity, survival probability, fish size, and morphological traits with respect to tidal height. Mark-recapture methods were used over a five month period to determine if individuals in high shore pools had greater site fidelity; fish in high tide pools were more than twice as likely to be recaptured in their original pool than fish from low tide pools. High pool individuals were, on average, smaller with larger eyes and longer snouts relative to their size as compared to low pool individuals. We discuss several mechanisms that could cause the observed pattern in morphological variation. Ultimately, this study suggests that within species behaviour and morphology differ by tidal position for an intertidal fish.

  17. The effects of mobile applications in cardiopulmonary assessment education.

    PubMed

    Yoo, In-Young; Lee, Young-Mi

    2015-02-01

    Mobile applications can be used as effective simulations for nursing education. However, little is known regarding the effects of mobile application-mediated training on nursing. The aim of this study was to determine the effectiveness of mobile applications by comparing the effectiveness of a high-fidelity human patient simulator to that of a mobile application on student learning. Following lectures on the lungs and the heart, twenty-two students were separated into two groups to perform a simulation exercise. Then, the students' education effects were evaluated based on their knowledge of lung and heart assessments, their clinical assessment skill, and satisfaction with their education. After four weeks, the mobile application group maintained their knowledge, whereas the high-fidelity human patient simulator group exhibited significantly decreased knowledge of the lung assessment. Knowledge of the heart assessment was significantly increased in both groups. There was no significant difference in clinical assessment skill or educational satisfaction between the groups. We found that mobile applications provide educational tools similarly effective to a high-fidelity human patient simulator to maintain memory and to teach cardiopulmonary assessment skills. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Implementation of a Smeared Crack Band Model in a Micromechanics Framework

    NASA Technical Reports Server (NTRS)

    Pineda, Evan J.; Bednarcyk, Brett A.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    The smeared crack band theory is implemented within the generalized method of cells and high-fidelity generalized method of cells micromechanics models to capture progressive failure within the constituents of a composite material while retaining objectivity with respect to the size of the discretization elements used in the model. An repeating unit cell containing 13 randomly arranged fibers is modeled and subjected to a combination of transverse tension/compression and transverse shear loading. The implementation is verified against experimental data (where available), and an equivalent finite element model utilizing the same implementation of the crack band theory. To evaluate the performance of the crack band theory within a repeating unit cell that is more amenable to a multiscale implementation, a single fiber is modeled with generalized method of cells and high-fidelity generalized method of cells using a relatively coarse subcell mesh which is subjected to the same loading scenarios as the multiple fiber repeating unit cell. The generalized method of cells and high-fidelity generalized method of cells models are validated against a very refined finite element model.

  19. Progressive Failure of a Unidirectional Fiber-Reinforced Composite Using the Method of Cells: Discretization Objective Computational Results

    NASA Technical Reports Server (NTRS)

    Pineda, Evan J.; Bednarcyk, Brett A.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    The smeared crack band theory is implemented within the generalized method of cells and high-fidelity generalized method of cells micromechanics models to capture progressive failure within the constituents of a composite material while retaining objectivity with respect to the size of the discretization elements used in the model. An repeating unit cell containing 13 randomly arranged fibers is modeled and subjected to a combination of transverse tension/compression and transverse shear loading. The implementation is verified against experimental data (where available), and an equivalent finite element model utilizing the same implementation of the crack band theory. To evaluate the performance of the crack band theory within a repeating unit cell that is more amenable to a multiscale implementation, a single fiber is modeled with generalized method of cells and high-fidelity generalized method of cells using a relatively coarse subcell mesh which is subjected to the same loading scenarios as the multiple fiber repeating unit cell. The generalized method of cells and high-fidelity generalized method of cells models are validated against a very refined finite element model.

  20. Forward and backward tone mapping of high dynamic range images based on subband architecture

    NASA Astrophysics Data System (ADS)

    Bouzidi, Ines; Ouled Zaid, Azza

    2015-01-01

    This paper presents a novel High Dynamic Range (HDR) tone mapping (TM) system based on sub-band architecture. Standard wavelet filters of Daubechies, Symlets, Coiflets and Biorthogonal were used to estimate the proposed system performance in terms of Low Dynamic Range (LDR) image quality and reconstructed HDR image fidelity. During TM stage, the HDR image is firstly decomposed in sub-bands using symmetrical analysis-synthesis filter bank. The transform coefficients are then rescaled using a predefined gain map. The inverse Tone Mapping (iTM) stage is straightforward. Indeed, the LDR image passes through the same sub-band architecture. But, instead of reducing the dynamic range, the LDR content is boosted to an HDR representation. Moreover, in our TM sheme, we included an optimization module to select the gain map components that minimize the reconstruction error, and consequently resulting in high fidelity HDR content. Comparisons with recent state-of-the-art methods have shown that our method provides better results in terms of visual quality and HDR reconstruction fidelity using objective and subjective evaluations.

Top