Portable and programmable clinical EOG diagnostic system.
Chen, S C; Tsai, T T; Luo, C H
2000-01-01
Monitoring eye movements is clinically important in diagnosis of diseases of the central nervous system. Electrooculography (EOG) is one method of obtaining such records which uses skin electrodes, and utilizes the anterior posterior polarization of the eye. A new EOG diagnostic system has been developed that utilizes two off-the-shelf portable notebook computers, one projector and simple electronic hardware. It can be operated under Windows 95, 98, NT, and has significant advantages over any other similar equipment, including programmability, portability, improved safety and low cost. Especially, portability of the instrument is extremely important for acutely ill or handicapped patients. The purpose of this paper is to introduce the techniques of computer animation, data acquisition, real time analysis of measured data, and database management to implement a portable, programmable and inexpensive contacting EOG instrument. It is very convenient to replace the present expensive, inflexible and large-sized commercially available EOG instruments. A lot of interesting stimulation patterns for clinical application can be created easily in different shape, time sequence, and colour by programming in Delphi language. With the help of Winstar (a software package that is used to control I/O and interrupt functions of the computer under Windows 95, 98, NT), the I/O communication between two notebook computers and A/D interface module can be effectively programmed. In addition, the new EOG diagnostic system is battery operated and it has the advantages of low noise as well as isolation from electricity. Two kinds of EOG tests, pursuit and saccade, were performed on 20 normal subjects with this new portable and programmable instrument. Based on the test result, the performance of the new instrument is superior to the other commercially available instruments. In conclusion, we hope that it will be more convenient for doctors and researchers to do the clinical EOG diagnosis and basic medical science research by using this new creation.
Thai Grade 11 Students' Alternative Conceptions for Acid-Base Chemistry
ERIC Educational Resources Information Center
Artdej, Romklao; Ratanaroutai, Thasaneeya; Coll, Richard Kevin; Thongpanchang, Tienthong
2010-01-01
This study involved the development of a two-tier diagnostic instrument to assess Thai high school students' understanding of acid-base chemistry. The acid-base diagnostic test (ABDT) comprising 18 items was administered to 55 Grade 11 students in a science and mathematics programme during the second semester of the 2008 academic year. Analysis of…
ERIC Educational Resources Information Center
Taber, Keith S.; Tan, Kim Chwee Daniel
2011-01-01
The present study contributes to the constructivist research programme (RP) into learning science by comparing patterns in responses from two groups of learners--senior high school students and pre-service teachers--in the same educational context (Singapore), to a diagnostic instrument relating to the topic of ionisation energies. This topic is…
ERIC Educational Resources Information Center
Benarroch, Alicia; Perez, Silvia; Perales, Javier
2011-01-01
Introduction: Variables that predict the eating behaviour of teenagers are a high-priority objective of nutritional educational programmes. This research work is designed to verify whether the "Food Consumption, Intentions and Preferences Assessment Test" (FCIPAT) is useful when investigating the factors influencing adolescent eating…
An Initial Study of the Diagnostic Utility of the Emotional and Behavioural Screener in Lithuania
ERIC Educational Resources Information Center
Sointu, Erkko; Lambert, Matthew C.; Nordness, Philip D.; Geležiniene, Renata; Epstein, Michael H.
2018-01-01
In schools, screening is an effective method to identify students at-risk for emotional and behavioural disorders. Several intervention programmes such as Positive Behaviour Interventions and Supports, Response to Intervention, and Multi-tiered Systems of Supports call for the use of psychometrically sound screening instruments. This study…
Dielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, Peter R. C.; Vykoukal, Jody V.
2009-01-01
As the molecular origins of disease are better understood, the need for affordable, rapid, and automated technologies that enable microscale molecular diagnostics has become apparent. Widespread use of microsystems that perform sample preparation and molecular analysis could ensure that the benefits of new biomedical discoveries are realized by a maximum number of people, even those in environments lacking any infrastructure. While progress has been made in developing miniaturized diagnostic systems, samples are generally processed off-device using labor-intensive and time-consuming traditional sample preparation methods. We present the concept of an integrated programmable general-purpose sample analysis processor (GSAP) architecture where raw samples are routed to separation and analysis functional blocks contained within a single device. Several dielectrophoresis-based methods that could serve as the foundation for building GSAP functional blocks are reviewed including methods for cell and particle sorting, cell focusing, cell ac impedance analysis, cell lysis, and the manipulation of molecules and reagent droplets. PMID:19684877
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
Linden, Ariel
2006-04-01
Diagnostic or predictive accuracy concerns are common in all phases of a disease management (DM) programme, and ultimately play an influential role in the assessment of programme effectiveness. Areas, such as the identification of diseased patients, predictive modelling of future health status and costs and risk stratification, are just a few of the domains in which assessment of accuracy is beneficial, if not critical. The most commonly used analytical model for this purpose is the standard 2 x 2 table method in which sensitivity and specificity are calculated. However, there are several limitations to this approach, including the reliance on a single defined criterion or cut-off for determining a true-positive result, use of non-standardized measurement instruments and sensitivity to outcome prevalence. This paper introduces the receiver operator characteristic (ROC) analysis as a more appropriate and useful technique for assessing diagnostic and predictive accuracy in DM. Its advantages include; testing accuracy across the entire range of scores and thereby not requiring a predetermined cut-off point, easily examined visual and statistical comparisons across tests or scores, and independence from outcome prevalence. Therefore the implementation of ROC as an evaluation tool should be strongly considered in the various phases of a DM programme.
A Reconfigurable Instrument System for Nuclear and Particle Physics Experiments
NASA Astrophysics Data System (ADS)
Sang, Ziru; Li, Feng; Jiang, Xiao; Jin, Ge
2014-04-01
We developed a reconfigurable nuclear instrument system (RNIS) that could satisfy the requirements of diverse nuclear and particle physics experiments, and the inertial confinement fusion diagnostic. Benefiting from the reconfigurable hardware structure and digital pulse processing technology, RNIS shakes off the restrictions of cumbersome crates and miscellaneous modules. It retains all the advantages of conventional nuclear instruments and is more flexible and portable. RNIS is primarily composed of a field programmable hardware board and relevant PC software. Separate analog channels are designed to provide different functions, such as amplifiers, ADC, fast discriminators and Schmitt discriminators for diverse experimental purposes. The high-performance field programmable gate array could complete high-precision time interval measurement, histogram accumulation, counting, and coincidence anticoincidence measurement. To illustrate the prospects of RNIS, a series of applications to the experiments are described in this paper. The first, for which RNIS was originally developed, involves nuclear energy spectrum measurement with a scintillation detector and photomultiplier. The second experiment applies RNIS to a G-M tube counting experiment, and in the third, it is applied to a quantum communication experiment through reconfiguration.
Integrating labview into a distributed computing environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasemir, K. U.; Pieck, M.; Dalesio, L. R.
2001-01-01
Being easy to learn and well suited for a selfcontained desktop laboratory setup, many casual programmers prefer to use the National Instruments Lab-VIEW environment to develop their logic. An ActiveX interface is presented that allows integration into a plant-wide distributed environment based on the Experimental Physics and Industrial Control System (EPICS). This paper discusses the design decisions and provides performance information, especially considering requirements for the Spallation Neutron Source (SNS) diagnostics system.
Evaluation of a web-based ECG-interpretation programme for undergraduate medical students.
Nilsson, Mikael; Bolinder, Gunilla; Held, Claes; Johansson, Bo-Lennart; Fors, Uno; Ostergren, Jan
2008-04-23
Most clinicians and teachers agree that knowledge about ECG is of importance in the medical curriculum. Students at Karolinska Institute have asked for more training in ECG-interpretation during their undergraduate studies. Clinical tutors, however, have difficulties in meeting these demands due to shortage of time. Thus, alternative ways to learn and practice ECG-interpretation are needed. Education offered via the Internet is readily available, geographically independent and flexible. Furthermore, the quality of education may increase and become more effective through a superior educational approach, improved visualization and interactivity. A Web-based comprehensive ECG-interpretation programme has been evaluated. Medical students from the sixth semester were given an optional opportunity to access the programme from the start of their course. Usage logs and an initial evaluation survey were obtained from each student. A diagnostic test was performed in order to assess the effect on skills in ECG interpretation. Students from the corresponding course, at another teaching hospital and without access to the ECG-programme but with conventional teaching of ECG served as a control group. 20 of the 32 students in the intervention group had tested the programme after 2 months. On a five-graded scale (1- bad to 5 - very good) they ranked the utility of a web-based programme for this purpose as 4.1 and the quality of the programme software as 3.9. At the diagnostic test (maximal points 16) by the end of the 5-month course at the 6th semester the mean result for the students in the intervention group was 9.7 compared with 8.1 for the control group (p = 0.03). Students ranked the Web-based ECG-interpretation programme as a useful instrument to learn ECG. Furthermore, Internet-delivered education may be more effective than traditional teaching methods due to greater immediacy, improved visualisation and interactivity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharp, H.E.; Lin, J.W. III; Macha, E.S.
1984-12-04
A borehole survey instrument is provided having a meniscus type floating compass member with indicia thereon for indicating azimuth and inclination. A light source is disposed below the indicia for illuminating the indicia upward through the liquid through which the meniscus type floating compass member floats. A lens system is provided for focusing the image of the illuminated compass member upon a film disposed below the compass member. This arrangement permits the centering post for the compass member to be of minimum diameter consistent with rigidity requirements and permits a high angle compass member to indicate angles of inclination approachingmore » ninety degrees. A multiple light bulb light source is utilized and each light bulb is mounted in a manner which permits a single light bulb to illuminate the entire compass member. A hand-held programming and diagnostic unit is provided which may be momentarily electrically mated with the borehole survey tool to input a programmed timed delay and diagnostically test both the condition of the light bulbs utilized as the illumination source and the state of the batteries within the instrument. This hand-held programmable unit eliminates all the mechanical programming switches and permits the instrument to be completely sealed from the pressure, fluids and contaminants normally found in a well bore.« less
Thai Grade 11 students' alternative conceptions for acid-base chemistry
NASA Astrophysics Data System (ADS)
Artdej, Romklao; Ratanaroutai, Thasaneeya; Coll, Richard Kevin; Thongpanchang, Tienthong
2010-07-01
This study involved the development of a two-tier diagnostic instrument to assess Thai high school students' understanding of acid-base chemistry. The acid-base diagnostic test (ABDT) comprising 18 items was administered to 55 Grade 11 students in a science and mathematics programme during the second semester of the 2008 academic year. Analysis of students' responses from this study followed the methodology outlined by Çalik and Ayas. The research findings suggest that the ABDT, the multiple choice diagnostic instrument, enables researchers and teachers to classify students' understanding at different levels. Most students exhibited alternative conceptions for several concepts: acid-base theory, dissociation of strong acids or bases, and dissociation of weak acids/bases. Interestingly, one of the concepts that students appeared to find most difficult, and for which they exhibited the most alternative conceptions, was acid-base theory. Some alternative conceptions revealed in this study differ from earlier reports, such as the concept of electrolyte and non-electrolyte solutions as well as the concentration changes of H3O+and OH- in water. These research findings present valuable information for facilitating better understanding of acid-base chemistry by providing insight into the preventable and correctable alternative conceptions exhibited by students.
Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul
2013-07-21
Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format.
Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul
2013-01-01
Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format. PMID:23685876
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2013 CFR
2013-04-01
... Portable air compressor 2 Cardiovascular Panel Cardiovascular Diagnostic 870.1425 Programmable diagnostic... Pacemaker & Accessories 870.1750 External programmable pacemaker pulse generator 2 870.3630 Pacemaker...
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2014 CFR
2014-04-01
... Portable air compressor 2 Cardiovascular Panel Cardiovascular Diagnostic 870.1425 Programmable diagnostic... Pacemaker & Accessories 870.1750 External programmable pacemaker pulse generator 2 870.3630 Pacemaker...
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2012 CFR
2012-04-01
... Portable air compressor 2 Cardiovascular Panel Cardiovascular Diagnostic 870.1425 Programmable diagnostic... Pacemaker & Accessories 870.1750 External programmable pacemaker pulse generator 2 870.3630 Pacemaker...
A hospital-based child protection programme evaluation instrument: a modified Delphi study.
Wilson, Denise; Koziol-McLain, Jane; Garrett, Nick; Sharma, Pritika
2010-08-01
Refine instrument for auditing hospital-based child abuse and neglect violence intervention programmes prior to field-testing. A modified Delphi study to identify and rate items and domains indicative of an effective and quality child abuse and neglect intervention programme. Experts participated in four Delphi rounds: two surveys, a one-day workshop and the opportunity to comment on the penultimate instrument. New Zealand. Twenty-four experts in the field of care and protection of children. Items with panel agreement >or=85% and mean importance rating >or=4.0 (scale from 1 (not important) to 5 (very important)). There was high-level consensus on items across Rounds 1 and 2 (89% and 85%, respectively). In Round 3 an additional domain (safety and security) was agreed upon and cultural issues, alert systems for children at risk, and collaboration among primary care, community, non-government and government agencies were discussed. The final instrument included nine domains ('policies and procedures', 'safety and security', 'collaboration', 'cultural environment', 'training of providers', 'intervention services', 'documentation' 'evaluation' and 'physical environment') and 64 items. The refined instrument represents the hallmarks of an ideal child abuse and neglect programme given current knowledge and experience. The instrument enables rigorous evaluations of hospital-based child abuse and neglect intervention programmes for quality improvement and benchmarking with other programmes.
Introducing new diagnostics into STI control programmes: the importance of programme science.
Peeling, Rosanna W; Mabey, David; Ballard, Ronald C
2013-03-01
Many innovative diagnostic technologies will become commercially available over the next 5-10 years. These tests can potentially transform the diagnosis of sexually transmitted infections but their introduction into control programmes can be hampered by health system constraints, and political, cultural, socioeconomic and behavioural factors. We used the introduction of syphilis rapid tests to illustrate the importance of programme science to address the gap between accruing evidence of acceptable test performance and the complexity of programme design, implementation and evaluation of test deployment to address public health needs and improve patient-important outcomes.
FNAC: its role, limitations and perspective in the preoperative diagnosis of breast cancer.
Zagorianakou, P; Fiaccavento, S; Zagorianakou, N; Makrydimas, G; Stefanou, D; Agnantis, N J
2005-01-01
Fine-needle aspiration cytology (FNAC) was first described and performed in 1930. Thirty years later, it gained acceptance first in Europe and about a decade later in North America. The method is generally considered as a rapid, reliable, safe diagnostic tool to distinguish non-neoplastic from neoplastic breast lesions. In developed countries, in the last 20 years, mammographic screening programmes, which have been used extensively, are designed to detect the earliest possible breast cancer. The FNAC report is extremely important because it gives the necessary information for the management of patients, in order to proceed with more invasive diagnostic methods or surgical treatment, and to decide what kind of operation to perform. In the preoperative phase, FNAC has taken a fundamental role of both palpable and nonpalpable lesions, using ultrasound or stereotactic guidance. New developed techniques, breast biopsy instrumentation (ABBI) and mammotome have the advantage of complete removal of breast lesions, but this is not possible in all the examined cases. In developing countries, economical restrictions, low budget for health care and screening programmes put the patients at a disadvantage because of the high cost of sophisticated diagnostic methods, thus we recommend that FNAC be used as a routine diagnostic method because of its low cost compared with the others and this policy maximizes the availability of health care to women with breast cancer. We conclude that FNAC plays an important and essential role in the management of patients with breast lesions and also offers a great potential for prediction of patient outcome, disease response to therapy and assessment of risk of developing breast cancer. The reliability and efficiency of the method depends on the quality of the samples and the experience of the medical staff that performs the aspiration.
Vassileva, J; Dimov, A; Slavchev, A; Karadjov, A
2005-01-01
Results from a Bulgarian patient dose survey in diagnostic radiology are presented. Reference levels for entrance surface dose (ESD) were 0.9 mGy for chest radiography (PA), 30 mGy for lumbar spine (Lat), 10 mGy for pelvis, 5 mGy for skull (AP), 3 mGy for skull (Lat) and 13 mGy for mammography. Quality control (QC) programmes were proposed for various areas of diagnostic radiology. Film processing QC warranted special attention. Proposed QC programmes included parameters to be tested, level of expertise needed and two action levels: remedial and suspension. Programmes were tested under clinical conditions to assess initial results and draw conclusions for further QC system development. On the basis of international experience, measurement protocols were developed for all parameters tested. QC equipment was provided as part of the PHARE project. A future problem for QC programme implementation may be the small number of medical physics experts in diagnostic radiology.
Laser Metalworking Technology Transfer.
1986-01-01
TI 59 programmable calculator /printer...the .4 one-dimensional heat flow model and should not be used for low processing speed. The program is written for use on a Texas Instrument TI 59 programmable calculator with...speed range, and a three-dimensional model for the low speed ranges. The program is written for use on a Texas Instrument TI 59 . * programmable calculator
Lee, Yun Jin; Kim, Jung Yoon
2016-03-01
The objective of this study was to evaluate the effect of pressure ulcer classification system education on clinical nurses' knowledge and visual differential diagnostic ability of pressure ulcer (PU) classification and incontinence-associated dermatitis (IAD). One group pre and post-test was used. A convenience sample of 407 nurses, participating in PU classification education programme of continuing education, were enrolled. The education programme was composed of a 50-minute lecture on PU classification and case-studies. The PU Classification system and IAD knowledge test (PUCS-KT) and visual differential diagnostic ability tool (VDDAT), consisting of 21 photographs including clinical information were used. Paired t-test was performed using SPSS/WIN 20.0. The overall mean difference of PUCS-KT (t = -11·437, P<0·001) and VDDAT (t = -21·113, P<0·001) was significantly increased after PU classification education. Overall understanding of six PU classification and IAD after education programme was increased, but lacked visual differential diagnostic ability regarding Stage III PU, suspected deep tissue injury (SDTI), and Unstageable. Continuous differentiated education based on clinical practice is needed to improve knowledge and visual differential diagnostic ability for PU classification, and comparison experiment study is required to examine effects of education programmes. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
40+ Years of Instrumentation for the La Silla Paranal Observatory
NASA Astrophysics Data System (ADS)
D'Odorico, S.
2018-03-01
As ESO Period 100 comes to a close, I look back at the development of ESO's instrumentation programme over more than 40 years. Instrumentation and detector activities were initially started by a small group of designers, engineers, technicians and astronomers while ESO was still at CERN in Geneva in the late 1970s. They have since led to the development of a successful suite of optical and infrared instruments for the La Silla Paranal Observatory, as testified by the continuous growth in the number of proposals for observing time and in the publications based on data from ESO telescopes. The instrumentation programme evolved significantly with the VLT and most instruments were developed by national institutes in close cooperation with ESO. This policy was a cornerstone of the VLT programme from the beginning and a key to its success.
Secondary prevention at 360°: the important role of diagnostic imaging.
Ciarrapico, Anna Micaela; Manenti, Guglielmo; Pistolese, Chiara; Fabiano, Sebastiano; Fiori, Roberto; Romagnoli, Andrea; Sergiacomi, Gianluigi; Stefanini, Matteo; Simonetti, Giovanni
2015-06-01
The aim of this paper is to underline the importance of the role of general practitioners (GPs) in distributing vital information about prevention to citizens, to highlight the importance of the so-called voluntary prevention programmes, both for conditions for which no organised screening programmes exist and for those for which they do exist but may well be obsolete or inefficient. Nowadays, voluntary prevention is made more effective thanks to the new sophisticated diagnostic technologies applied worldwide by diagnostic imaging. Epidemiological data about the incidence and causes of death among the Italian population have shown that screening programmes should be aimed first at fighting the following diseases: prostatic carcinoma, lung cancer, colorectal carcinoma, breast cancer, cardiovascular disease, cerebrovascular disease, aortic and peripheral vascular disease. GPs do not generally give good or adequate instructions concerning voluntary prevention programmes; GPs may not even be aware of this type of prevention which could represent a valuable option together with the existing mass screening programmes. Therefore, in the following analysis, we aim to outline the correct diagnostic pathway for the prevention of diseases having the highest incidence in our country and which represent the most frequent causes of death. If used correctly, these screening programmes may contribute to the success of secondary prevention, limiting the use of tertiary prevention and thus producing savings for the Italian National Health System.
1981-06-01
TI - 59 programmable calculator to aid...training. The Texas Instruments TI - 59 Programmable Calculator has only ten lettered registers that would be simple for clerical personnel to use (A...SASSY Management Units. Appendix C is a set of user instructions written for the Texas Instrument TI - 59 Programmable Calculator . The TI-59 was
A Review and Comparison of Diagnostic Instruments to Identify Students' Misconceptions in Science
ERIC Educational Resources Information Center
Gurel, Derya Kaltakci; Eryilmaz, Ali; McDermott, Lillian Christie
2015-01-01
Different diagnostic tools have been developed and used by researchers to identify students' conceptions. The present study aimed to provide an overview of the common diagnostic instruments in science to assess students' misconceptions. Also the study provides a brief comparison of these common diagnostic instruments with their strengths and…
A lab-on-chip for malaria diagnosis and surveillance
2014-01-01
Background Access to timely and accurate diagnostic tests has a significant impact in the management of diseases of global concern such as malaria. While molecular diagnostics satisfy this need effectively in developed countries, barriers in technology, reagent storage, cost and expertise have hampered the introduction of these methods in developing countries. In this study a simple, lab-on-chip PCR diagnostic was created for malaria that overcomes these challenges. Methods The platform consists of a disposable plastic chip and a low-cost, portable, real-time PCR machine. The chip contains a desiccated hydrogel with reagents needed for Plasmodium specific PCR. Chips can be stored at room temperature and used on demand by rehydrating the gel with unprocessed blood, avoiding the need for sample preparation. These chips were run on a custom-built instrument containing a Peltier element for thermal cycling and a laser/camera setup for amplicon detection. Results This diagnostic was capable of detecting all Plasmodium species with a limit of detection for Plasmodium falciparum of 2 parasites/μL of blood. This exceeds the sensitivity of microscopy, the current standard for diagnosis in the field, by ten to fifty-fold. In a blind panel of 188 patient samples from a hyper-endemic region of malaria transmission in Uganda, the diagnostic had high sensitivity (97.4%) and specificity (93.8%) versus conventional real-time PCR. The test also distinguished the two most prevalent malaria species in mixed infections, P. falciparum and Plasmodium vivax. A second blind panel of 38 patient samples was tested on a streamlined instrument with LED-based excitation, achieving a sensitivity of 96.7% and a specificity of 100%. Conclusions These results describe the development of a lab-on-chip PCR diagnostic from initial concept to ready-for-manufacture design. This platform will be useful in front-line malaria diagnosis, elimination programmes, and clinical trials. Furthermore, test chips can be adapted to detect other pathogens for a differential diagnosis in the field. The flexibility, reliability, and robustness of this technology hold much promise for its use as a novel molecular diagnostic platform in developing countries. PMID:24885206
21 CFR 892.1870 - Radiographic film/cassette changer programmer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...
21 CFR 892.1870 - Radiographic film/cassette changer programmer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...
21 CFR 892.1870 - Radiographic film/cassette changer programmer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...
21 CFR 892.1870 - Radiographic film/cassette changer programmer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...
21 CFR 892.1870 - Radiographic film/cassette changer programmer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...
MOEMs devices designed and tested for future astronomical instrumentation in space
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Waldis, Severin; Noell, Wilfried; Conedera, Veronique; Fabre, Norbert; Viard, Thierry; Buisset, Christophe
2017-11-01
Next generation of astronomical instrumentation for space telescopes requires Micro-Opto-Electro- Mechanical Systems (MOEMS) with remote control capability and cryogenic operation. MOEMS devices have the capability to tailor the incoming light in terms of intensity and object selection with programmable slit masks, in terms of phase and wavefront control with micro-deformable mirrors, and finally in terms of spectrum with programmable diffraction gratings. Applications are multi-object spectroscopy (MOS), wavefront correction and programmable spectrographs. We are engaged since several years in the design, realization and characterization of MOEMS devices suited for astronomical instrumentation.
Hessel, F P; Wittmann, M; Petro, W; Wasem, J
2000-07-01
Studies in health economics especially economic evaluations of health care technologies and programmes are getting more and more important. However, in Germany there are no established, validated and commonly used instruments for the costing process. For the economic evaluation of a rehabilitation programme for patients with chronic lung diseases such as asthma and chronic bronchitis we developed methods for identification, measurement and validation of resource use during the inpatient rehabilitation programme and during the outpatient follow-up period. These methods are based on methodological considerations as well as on practical experience from conducting a pilot study. With regard to the inpatient setting all relevant diagnostic and therapeutic resource uses could be measured basing on routine clinical documentation and validated by using the cost accounting of the clinic. For measuring the use of resources during the follow-up period in an outpatient setting no reliable administrative data are accessible. Hence, we compared a standardised retrospective patient questionnaire used in a 20-minute interview (n = 50) and a cost diary for the continuing documentation by the patient over a period of 4 weeks (n = 50). Both tools were useful for measuring all relevant resource uses in sufficient detail, but because of higher participation rates and lower dropouts the structured interview appears to be more suitable. Average total costs per month were 1591 DM (interview), respectively 1867 DM (cost diary). Besides productivity loss, costs for medication and GP visits caused the relatively highest resource uses. Practicable instruments were developed for the costing process as part of an economic evaluation in a German rehabilitation setting for pulmonary diseases. After individual modification, these could also be used for different indications and in other institutional settings.
Benjelloun, Fatima-Zohra Madani; Chabraoui, Layachi; Kriouile, Yamna
2017-01-01
Introduction L'adrénoleucodystrophie liée à l'X (X-ALD) est une maladie neurodégénérative sévère, due à des mutations du gène ABCD1. Elle se manifeste par une atteinte du système nerveux central et périphérique, une insuffisance surrénalienne et une atteinte des testicules chez le garçon. Son diagnostic repose sur le dosage des Acides Gras à Très Longue Chaine. Le diagnostic précoce est d'une grande importance puisque il définit l'accessibilité aux traitements selon le stage de la maladie. Méthodes Nous avons mis en place un programme de diagnostic de l'X-ALD au Maroc au niveau de l'Hôpital d'enfants et du Laboratoire centrale des maladies héréditaires et du métabolisme de Rabat. Le programme s'articule sur trois axes à savoir : le recrutement des patients, le diagnostic et la sensibilisation. Le diagnostic s'effectue selon trois protocoles : un protocole pour les cas symptomatiques, un deuxième pour les cas asymptomatiques et un troisième pour les femmes hétérozygotes. Résultats Durant trois ans après la mise en place de notre programme de diagnostic de l'Adrénoleucodystrophie liée à l'X, nous avons diagnostiqué la maladie chez sept familles, avec neuf garçons et trois femmes hétérozygotes. Tous les enfants diagnostiqués présentaient la forme cérébrale démyélinisante. Toutes les femmes hétérozygotes étaient asymptomatiques. Une prise en charge thérapeutique a été mise place selon la symptomatologie de chaque cas. Conclusion l'X-ALD est une maladie rare. Notre programme de diagnostique a permis de diagnostiquer un nombre important de cas, ce qui montre son importance. Les compagnes de sensibilisation auprès des professionnels permettront de mieux comprendre la maladie et mieux la diagnostiquer et ainsi donner accès à un nombre plus élevé de patients. PMID:29599883
Sterdt, Elena; Pape, Natalie; Kramer, Silke; Urban, Michael; Werning, Rolf; Walter, Ulla
2013-09-03
Preschools offer high potential for preventive interventions. However, little is known about the structure of preschool programmes to promote physical activity (PA) in preschoolers although almost all children aged three to six years spend one third of the day at preschool. The aim of this study was to determine whether and to what extent preschools implement systematic PA promotion measures using an instrument specifically developed to assess and systematize preschool PA programmes. In the cross-sectional study a baseline survey of preschool education policies was conducted to identify and assess the type and extent of PA programmes and opportunities in preschools in the State of Lower Saxony, Germany. An assessment instrument was developed to identify preschools with systematic PA programmes (type 1) and those without PA programmes (type 2) based on the following quality criteria: A) written PA policy, B) structured weekly PA offerings for all children; C) at least one qualified physical education teacher; D) PA-friendly indoor and outdoor facilities (exercise room, situational PA opportunities, outdoor areas, play equipment etc.), and E) structured PA promotion in place for at least two years. A third type of preschool that promotes PA in children to some extent (i.e., that meets the criteria partially but not completely) was classified as "preschools with limited PA programmes". 2415 preschools participated in the survey (response rate: 59%). The results show that 26% (n = 554) have a systematic PA programme while 3% (n = 64) have no PA programme. Most (71%, n = 1514) were classified as limited PA programme preschools. All three types of preschools differed significantly (p = .000) from each other in terms of size (small vs. large). Most of the preschools without PA programmes are small half-day preschools. The study investigated an assessment-instrument providing extensive insight into the nature, extent and routine practical implementation of PA promotion in preschools. The criteria used to evaluate preschool PA programmes are well-suited to identify the different preschool PA programme types and target areas in the field of PA promotion in which specific measures (teacher education, structured PA offerings, etc.) can be implemented in future interventions.
The report describes a version of EPA's electrostatic precipitator (ESP) model suitable for use on a Texas Instruments Programmable 59 (TI-59) hand-held calculator. This version of the model allows the calculation of ESP collection efficiency, including corrections for non-ideal ...
Instrumentation System Diagnoses a Thermocouple
NASA Technical Reports Server (NTRS)
Perotti, Jose; Santiago, Josephine; Mata, Carlos; Vokrot, Peter; Zavala, Carlos; Burns, Bradley
2008-01-01
An improved self-validating thermocouple (SVT) instrumentation system not only acquires readings from a thermocouple but is also capable of detecting deterioration and a variety of discrete faults in the thermocouple and its lead wires. Prime examples of detectable discrete faults and deterioration include open- and short-circuit conditions and debonding of the thermocouple junction from the object, the temperature of which one seeks to measure. Debonding is the most common cause of errors in thermocouple measurements, but most prior SVT instrumentation systems have not been capable of detecting debonding. The improved SVT instrumentation system includes power circuitry, a cold-junction compensator, signal-conditioning circuitry, pulse-width-modulation (PWM) thermocouple-excitation circuitry, an analog-to-digital converter (ADC), a digital data processor, and a universal serial bus (USB) interface. The system can operate in any of the following three modes: temperature measurement, thermocouple validation, and bonding/debonding detection. The software running in the processor includes components that implement statistical algorithms to evaluate the state of the thermocouple and the instrumentation system. When the power is first turned on, the user can elect to start a diagnosis/ monitoring sequence, in which the PWM is used to estimate the characteristic times corresponding to the correct configuration. The user also has the option of using previous diagnostic values, which are stored in an electrically erasable, programmable read-only memory so that they are available every time the power is turned on.
Programmable bio-nano-chip system for saliva diagnostics
NASA Astrophysics Data System (ADS)
Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W.; McRae, Michael P.; Wong, Jorge; Kosten, Thomas R.; Miller, Craig S.; Ebersole, Jeffrey L.; McDevitt, John
2014-06-01
This manuscript describes programmable Bio-Nano-Chip (p-BNC) approach that serves as miniaturized assay platform designed for the rapid detection and quantitation of multiple analytes in biological fluids along with the specific applications in salivary diagnostics intended for the point of need (PON). Included here are oral fluid-based tests for local periodontal disease, systemic cardiac disease and multiplexed tests for drugs of abuse.
NASA Astrophysics Data System (ADS)
Díaz-Ayil, G.; Amouroux, M.; Blondel, W. C. P. M.; Bourg-Heckly, G.; Leroux, A.; Guillemin, F.; Granjon, Y.
2009-07-01
This paper deals with the development and application of in vivo spatially-resolved bimodal spectroscopy (AutoFluorescence AF and Diffuse Reflectance DR), to discriminate various stages of skin precancer in a preclinical model (UV-irradiated mouse): Compensatory Hyperplasia CH, Atypical Hyperplasia AH and Dysplasia D. A programmable instrumentation was developed for acquiring AF emission spectra using 7 excitation wavelengths: 360, 368, 390, 400, 410, 420 and 430 nm, and DR spectra in the 390-720 nm wavelength range. After various steps of intensity spectra preprocessing (filtering, spectral correction and intensity normalization), several sets of spectral characteristics were extracted and selected based on their discrimination power statistically tested for every pair-wise comparison of histological classes. Data reduction with Principal Components Analysis (PCA) was performed and 3 classification methods were implemented (k-NN, LDA and SVM), in order to compare diagnostic performance of each method. Diagnostic performance was studied and assessed in terms of sensitivity (Se) and specificity (Sp) as a function of the selected features, of the combinations of 3 different inter-fibers distances and of the numbers of principal components, such that: Se and Sp ≈ 100% when discriminating CH vs. others; Sp ≈ 100% and Se > 95% when discriminating Healthy vs. AH or D; Sp ≈ 74% and Se ≈ 63%for AH vs. D.
innoFSPEC: fiber optical spectroscopy and sensing
NASA Astrophysics Data System (ADS)
Roth, Martin M.; Löhmannsröben, Hans-Gerd; Kelz, Andreas; Kumke, Michael
2008-07-01
innoFSPEC Potsdam is presently being established as in interdisciplinary innovation center for fiber-optical spectroscopy and sensing, hosted by Astrophysikalisches Institut Potsdam and the Physical Chemistry group of Potsdam University, Germany. The center focuses on fundamental research in the two fields of fiber-coupled multi-channel spectroscopy and optical fiber-based sensing. Thanks to its interdisciplinary approach, the complementary methodologies of astrophysics on the one hand, and physical chemistry on the other hand, are expected to spawn synergies that otherwise would not normally become available in more standard research programmes. innoFSPEC targets future innovations for next generation astrophysical instrumentation, environmental analysis, manufacturing control and process monitoring, medical diagnostics, non-invasive imaging spectroscopy, biopsy, genomics/proteomics, high-throughput screening, and related applications.
Instrumental Aid by Japanese Official Development Assistance for Astronomy in Developing Countries
NASA Astrophysics Data System (ADS)
Kitamura, Masatoshi
In order to promote education and research in developing countries, the Japanese Government has been providing developing countries with high-grade equipment under the framework of the Official Development Assistance (ODA) cooperation programme since 1982. Under this successful cooperation programme, 24 astronomical instruments have been donated to 19 developing countries up to the end of the Japanese fiscal year 2003. The instruments donated included university-level reflecting telescopes, as well as modern planetaria used for educational purposes, together with various accessories. This paper describes a continuation of the previous ODA donations (Astronomical Herald 1997) and the subsequent follow-up programmes provided with the assistance of Japan International Cooperation Agency (JICA).
Chowdhury, Shubhajit Roy; Chakrabarti, Dipankar; Hiranmay, Saha
2009-12-01
The paper proposes to develop a field programmable gate array (FPGA) based low cost, low power and high speed novel diagnostic system that can detect in absence of the physician the approaching critical condition of a patient at an early stage and is thus suitable for diagnosis of patients in the rural areas of developing countries where availability of physicians and availability of power is really scarce. The diagnostic system could be installed in health care centres of rural areas where patients can register themselves for periodic diagnoses and thereby detect potential health hazards at an early stage. Multiple pathophysiological parameters with different weights are involved in diagnosing a particular disease. A novel variation of particle swarm optimization called as adaptive perceptive particle swarm optimization has been proposed to determine the optimal weights of these pathophysiological parameters for a more accurate diagnosis. The FPGA based smart system has been applied for early detection of renal criticality of patients. For renal diagnosis, body mass index, glucose, urea, creatinine, systolic and diastolic blood pressures have been considered as pathophysiological parameters. The detection of approaching critical condition of a patient by the instrument has also been validated with the standard Cockford Gault Equation to verify whether the patient is really approaching a critical condition or not. Using Bayesian analysis on the population of 80 patients under study an accuracy of up to 97.5% in renal diagnosis has been obtained.
Roles of laboratories and laboratory systems in effective tuberculosis programmes.
Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul
2007-05-01
Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.
Polilli, Ennio; Sozio, Federica; Di Stefano, Paola; Clerico, Luigi; Di Iorio, Giancarlo; Parruti, Giustino
2018-04-01
This study aimed to analyze the efficacy of a Web-based testing programme in terms of the prevention of late HIV presentation. The clinical characteristics of patients diagnosed with HIV via the Web-based testing programme were compared to those of patients diagnosed in parallel via standard diagnostic care procedures. This study included the clinical and demographic data of newly diagnosed HIV patients enrolled at the study clinic between February 2014 and June 2017. These patients were diagnosed either via standard diagnostic procedures or as a result of the Web-based testing programme. Eighty-eight new cases of HIV were consecutively enrolled; their mean age was 39.1±13.0 years. Fifty-nine patients (67%) were diagnosed through standard diagnostic procedures and 29 (33%) patients came from the Web-based testing programme. Late presentation (62% vs. 34%, p=0.01) and AIDS-defining conditions at presentation (13 vs. 1, p=0.02) were significantly more frequent in the standard care group than in the Web-based group; four of 13 patients with AIDS diagnosed under standard diagnostic procedures died, versus none in the Web-based testing group (p<0.001). Web-based recruitment for voluntary and free HIV testing helped to diagnose patients with less advanced HIV disease and no risk of death, from all at-risk groups, in comparison with standard care testing. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
McCarthy, James S.; Lustigman, Sara; Yang, Guo-Jing; Barakat, Rashida M.; García, Héctor H.; Sripa, Banchob; Willingham, Arve Lee; Prichard, Roger K.; Basáñez, María-Gloria
2012-01-01
Diagnostic tools appropriate for undertaking interventions to control helminth infections are key to their success. Many diagnostic tests for helminth infection have unsatisfactory performance characteristics and are not well suited for use in the parasite control programmes that are being increasingly implemented. Although the application of modern laboratory research techniques to improve diagnostics for helminth infection has resulted in some technical advances, uptake has not been uniform. Frequently, pilot or proof of concept studies of promising diagnostic technologies have not been followed by much needed product development, and in many settings diagnosis continues to rely on insensitive and unsatisfactory parasitological or serodiagnostic techniques. In contrast, PCR-based xenomonitoring of arthropod vectors, and use of parasite recombinant proteins as reagents for serodiagnostic tests, have resulted in critical advances in the control of specific helminth parasites. The Disease Reference Group on Helminths Infections (DRG4), established in 2009 by the Special Programme for Research and Training in Tropical Diseases (TDR) was given the mandate to review helminthiases research and identify research priorities and gaps. In this review, the diagnostic technologies relevant to control of helminth infections, either available or in development, are reviewed. Critical gaps are identified and opportunities to improve needed technologies are discussed. PMID:22545166
Usability-driven evolution of a space instrument
NASA Astrophysics Data System (ADS)
McCalden, Alec
2012-09-01
The use of resources in the cradle-to-grave timeline of a space instrument might be significantly improved by considering the concept of usability from the start of the mission. The methodology proposed here includes giving early priority in a programme to the iterative development of a simulator that models instrument operation, and allowing this to evolve ahead of the actual instrument specification and fabrication. The advantages include reduction of risk in software development by shifting much of it to earlier in a programme than is typical, plus a test programme that uses and thereby proves the same support systems that may be used for flight. A new development flow for an instrument is suggested, showing how the system engineering phases used by the space agencies could be reworked in line with these ideas. This methodology is also likely to contribute to a better understanding between the various disciplines involved in the creation of a new instrument. The result should better capture the science needs, implement them more accurately with less wasted effort, and more fully allow the best ideas from all team members to be considered.
Juul, Jakob Søgaard; Andersen, Berit; Laurberg, Søren; Carlsen, Anders Helles; Olesen, Frede; Vedsted, Peter
2018-06-22
To investigate the diagnostic activity in general practice and the cumulative incidence of colorectal cancer (CRC) in individuals invited to the Danish national screening programme for CRC. A historical population-based cohort study. The Danish CRC screening programme and general practice. The 376,198 individuals invited to the Danish CRC screening programme from 1 March to 31 December 2014. The diagnostic activity (consultations and haemoglobin measures) in general practice in the year preceding the screening invitation and the cumulated incidence of CRC in the year following the screening invitation. Screening participants had significantly higher diagnostic activity than non-participants. Individuals with a positive faecal immunochemical test (FIT) had higher diagnostic activity compared to individuals with a negative FIT, and a small increase in the months leading up to the invitation. Individuals with a screen-detected CRC had lower diagnostic activity than individuals with no CRC. In total, 308 (25.3%) of CRCs diagnosed in the invited population were diagnosed outside the screening programme. Non-participants with CRC more often had low socio-economic status, high comorbidity and stage IV CRC than participants with CRC. There was a tendency that participants and those with a positive FIT had a higher diagnostic activity the year before the screening. This was not seen for those with CRC detected through screening. CRC must still be diagnosed in general practice in the invited population and non-participants are of special interest as they have higher risk of late stage CRC. Key Points Current awareness:Individuals with colorectal cancer (CRC) in screening may be symptomatic and CRC may still occur outside screening in the invited population. Most important points:The majority of individuals with CRC in screening cannot be expected to be diagnosed on symptomatic presentation in general practice GPs have to be aware that CRC still occurs outside screening in the invited population Non-participants with CRC are often deprived and have late stage CRC.
NASA Astrophysics Data System (ADS)
Tsui, Chi-Yan; Treagust, David
2010-05-01
While genetics has remained as one key topic in school science, it continues to be conceptually and linguistically difficult for students with the concomitant debates as to what should be taught in the age of biotechnology. This article documents the development and implementation of a two-tier multiple-choice instrument for diagnosing grades 10 and 12 students' understanding of genetics in terms of reasoning. The pretest and posttest forms of the diagnostic instrument were used alongside other methods in evaluating students' understanding of genetics in a case-based qualitative study on teaching and learning with multiple representations in three Western Australian secondary schools. Previous studies have shown that a two-tier diagnostic instrument is useful in probing students' understanding or misunderstanding of scientific concepts and ideas. The diagnostic instrument in this study was designed and then progressively refined, improved, and implemented to evaluate student understanding of genetics in three case schools. The final version of the instrument had Cronbach's alpha reliability of 0.75 and 0.64, respectively, for its pretest and the posttest forms when it was administered to a group of grade 12 students (n = 17). This two-tier diagnostic instrument complemented other qualitative data collection methods in this research in generating a more holistic picture of student conceptual learning of genetics in terms of scientific reasoning. Implications of the findings of this study using the diagnostic instrument are discussed.
Májek, O; Bartoňková, H; Daneš, J; Skovajsová, M; Dušek, L
2014-01-01
The Czech organised breast cancer screening programme was initiated in 2002. Collection of data on screening mammography examinations, subsequent diagnostic procedures, and final dia-gnosis is an indispensable part of the programme. Data collection is obligatory for all accredited centres, in accordance with regulations issued by the Czech Ministry of Health. This contribution aims to demonstrate the recent results of quality monitoring of the accredited centres. Quality indicators, whose definition complies with international standards, involve the women's participation, the volume of performed examinations, the accuracy of screening mammography, the use of preoperative diagnostics, and the proportion of early detected tumours. Our evaluation documents a continuous improvement in quality of the Czech mammography screening programme, which is thereby in full agreement with international recommendations on quality assurance.
Responding to Culture in the Instrumental Music Programme: A Teacher's Journey
ERIC Educational Resources Information Center
Abril, Carlos R.
2009-01-01
The purpose of this case study was to examine how one music teacher responds to student's cultural backgrounds through a middle school instrumental music programme in the US. The study sought to uncover the events, situations and circumstances that served as catalysts for curricular change and the rationales that gave it purpose. It also examined…
2013-01-01
Background Preschools offer high potential for preventive interventions. However, little is known about the structure of preschool programmes to promote physical activity (PA) in preschoolers although almost all children aged three to six years spend one third of the day at preschool. The aim of this study was to determine whether and to what extent preschools implement systematic PA promotion measures using an instrument specifically developed to assess and systematize preschool PA programmes. Methods In the cross-sectional study a baseline survey of preschool education policies was conducted to identify and assess the type and extent of PA programmes and opportunities in preschools in the State of Lower Saxony, Germany. An assessment instrument was developed to identify preschools with systematic PA programmes (type 1) and those without PA programmes (type 2) based on the following quality criteria: A) written PA policy, B) structured weekly PA offerings for all children; C) at least one qualified physical education teacher; D) PA-friendly indoor and outdoor facilities (exercise room, situational PA opportunities, outdoor areas, play equipment etc.), and E) structured PA promotion in place for at least two years. A third type of preschool that promotes PA in children to some extent (i.e., that meets the criteria partially but not completely) was classified as “preschools with limited PA programmes”. Results 2415 preschools participated in the survey (response rate: 59%). The results show that 26% (n = 554) have a systematic PA programme while 3% (n = 64) have no PA programme. Most (71%, n = 1514) were classified as limited PA programme preschools. All three types of preschools differed significantly (p = .000) from each other in terms of size (small vs. large). Most of the preschools without PA programmes are small half-day preschools. Conclusions The study investigated an assessment-instrument providing extensive insight into the nature, extent and routine practical implementation of PA promotion in preschools. The criteria used to evaluate preschool PA programmes are well-suited to identify the different preschool PA programme types and target areas in the field of PA promotion in which specific measures (teacher education, structured PA offerings, etc.) can be implemented in future interventions. PMID:24005037
Roles of laboratories and laboratory systems in effective tuberculosis programmes
van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul
2007-01-01
Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219
Williams, Jason; Umaru, Farouk; Edgil, Dianna; Kuritsky, Joel
2016-09-28
In 2014, the Joint United Nations Programme on HIV/AIDS released its 90-90-90 targets, which make laboratory diagnostics a cornerstone for measuring efforts toward the epidemic control of HIV. A data-driven laboratory harmonization and standardization approach is one way to create efficiencies and ensure optimal laboratory procurements. Following the 2008 "Maputo Declaration on Strengthening of Laboratory Systems"-a call for government leadership in harmonizing tiered laboratory networks and standardizing testing services-several national ministries of health requested that the United States Government and in-country partners help implement the recommendations by facilitating laboratory harmonization and standardization workshops, with a primary focus on improving HIV laboratory service delivery. Between 2007 and 2015, harmonization and standardization workshops were held in 8 African countries. This article reviews progress in the harmonization of laboratory systems in these 8 countries. We examined agreed-upon instrument lists established at the workshops and compared them against instrument data from laboratory quantification exercises over time. We used this measure as an indicator of adherence to national procurement policies. We found high levels of diversity across laboratories' diagnostic instruments, equipment, and services. This diversity contributes to different levels of compliance with expected service delivery standards. We believe the following challenges to be the most important to address: (1) lack of adherence to procurement policies, (2) absence or limited influence of a coordinating body to fully implement harmonization proposals, and (3) misalignment of laboratory policies with minimum packages of care and with national HIV care and treatment guidelines. Overall, the effort to implement the recommendations from the Maputo Declaration has had mixed success and is a work in progress. Program managers should continue efforts to advance the principles outlined in the Maputo Declaration. Quantification exercises are an important method of identifying instrument diversity, and provide an opportunity to measure efforts toward standardization. © Williams et al.
Williams, Jason; Umaru, Farouk; Edgil, Dianna; Kuritsky, Joel
2016-01-01
ABSTRACT In 2014, the Joint United Nations Programme on HIV/AIDS released its 90-90-90 targets, which make laboratory diagnostics a cornerstone for measuring efforts toward the epidemic control of HIV. A data-driven laboratory harmonization and standardization approach is one way to create efficiencies and ensure optimal laboratory procurements. Following the 2008 “Maputo Declaration on Strengthening of Laboratory Systems”—a call for government leadership in harmonizing tiered laboratory networks and standardizing testing services—several national ministries of health requested that the United States Government and in-country partners help implement the recommendations by facilitating laboratory harmonization and standardization workshops, with a primary focus on improving HIV laboratory service delivery. Between 2007 and 2015, harmonization and standardization workshops were held in 8 African countries. This article reviews progress in the harmonization of laboratory systems in these 8 countries. We examined agreed-upon instrument lists established at the workshops and compared them against instrument data from laboratory quantification exercises over time. We used this measure as an indicator of adherence to national procurement policies. We found high levels of diversity across laboratories’ diagnostic instruments, equipment, and services. This diversity contributes to different levels of compliance with expected service delivery standards. We believe the following challenges to be the most important to address: (1) lack of adherence to procurement policies, (2) absence or limited influence of a coordinating body to fully implement harmonization proposals, and (3) misalignment of laboratory policies with minimum packages of care and with national HIV care and treatment guidelines. Overall, the effort to implement the recommendations from the Maputo Declaration has had mixed success and is a work in progress. Program managers should continue efforts to advance the principles outlined in the Maputo Declaration. Quantification exercises are an important method of identifying instrument diversity, and provide an opportunity to measure efforts toward standardization. PMID:27688718
ERIC Educational Resources Information Center
Johnson, Bruce; Manoli, Constantinos C.
2008-01-01
Investigating the effects of educational programmes on children's environmental perceptions has been hampered by the lack of good theoretical models and valid instruments. In the present study, Bogner and Wiseman's Model of Ecological Values provided a well-developed theoretical model. A validated instrument based on Bogner's Environmental…
Owora, Arthur H; Carabin, Hélène; Reese, Jessica; Garwe, Tabitha
2016-09-01
Growing recognition of the interrelated negative outcomes associated with major depression disorder (MDD) among mothers and their children has led to renewed public health interest in the early identification and treatment of maternal MDD. Healthcare providers, however, remain unsure of the validity of existing case-finding instruments. We conducted a systematic review to identify the most valid maternal MDD case-finding instrument used in the United States. We identified articles reporting the sensitivity and specificity of MDD case-finding instruments based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) by systematically searching through three electronic bibliographic databases, PubMed, PsycINFO, and EMBASE, from 1994 to 2014. Study eligibility and quality were evaluated using the Standards for the Reporting of Diagnostic Accuracy studies and Quality Assessment of Diagnostic Accuracy Studies guidelines respectively. Overall, we retrieved 996 unduplicated articles and selected 74 for full-text review. Of these, 14 articles examining 21 different instruments were included in the systematic review. The 10 item Edinburgh Postnatal Depression Scale and Postpartum Depression Screening Scale had the most stable (lowest variation) and highest diagnostic performance during the antepartum and postpartum periods (sensitivity range: 0.63-0.94 and 0.67-0.95; specificity range: 0.83-0.98 and 0.68-0.97 respectively). Greater variation in diagnostic performance was observed among studies with higher MDD prevalence. Factors that explain greater variation in instrument diagnostic performance in study populations with higher MDD prevalence were not examined. Findings suggest that the diagnostic performance of maternal MDD case-finding instruments is peripartum period-specific. Published by Elsevier B.V.
MOEMs-based new functionalities for future instrumentation in space
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Liotard, Arnaud; Viard, Thierry; Costes, Vincent; Hébert, Philippe-Jean; Hinglais, Emmanuel; Villenave, Michel
2017-11-01
Micro-Opto-Electro-Mechanical Systems (MOEMS) could be key components in future generation of space instruments. In Earth Observation, Universe Observation and Planet Exploration, scientific return of the instruments must be optimized in future missions. MOEMS devices are based on the mature micro-electronics technology and in addition to their compactness, scalability, and specific task customization, they could generate new functions not available with current technologies. CNES has initiated a study with LAM and TAS for listing the new functions associated with several types of MEMS (programmable slits, programmable micro-diffraction gratings, micro-deformable mirrors). Instrumental applications are then derived and promising concepts are described.
Barriers to community case management of malaria in Saraya, Senegal: training, and supply-chains.
Blanas, Demetri A; Ndiaye, Youssoupha; Nichols, Kim; Jensen, Andrew; Siddiqui, Ammar; Hennig, Nils
2013-03-14
Health workers in sub-Saharan Africa can now diagnose and treat malaria in the field, using rapid diagnostic tests and artemisinin-based combination therapy in areas without microscopy and widespread resistance to previously effective drugs. This study evaluates communities' perceptions of a new community case management of malaria programme in the district of Saraya, south-eastern Senegal, the effectiveness of lay health worker trainings, and the availability of rapid diagnostic tests and artemisinin-based combination therapy in the field. The study employed qualitative and quantitative methods including focus groups with villagers, and pre- and post-training questionnaires with lay health workers. Communities approved of the community case management programme, but expressed concern about other general barriers to care, particularly transportation challenges. Most lay health workers acquired important skills, but a sizeable minority did not understand the rapid diagnostic test algorithm and were not able to correctly prescribe arteminisin-based combination therapy soon after the training. Further, few women lay health workers participated in the programme. Finally, the study identified stock-outs of rapid tests and anti-malaria medication products in over half of the programme sites two months after the start of the programme, thought due to a regional shortage. This study identified barriers to implementation of the community case management of malaria programme in Saraya that include lay health worker training, low numbers of women participants, and generalized stock-outs. These barriers warrant investigation into possible solutions of relevance to community case management generally.
Fibre optical spectroscopy and sensing innovation at innoFSPEC Potsdam
NASA Astrophysics Data System (ADS)
Haynes, Roger; Reich, Oliver; Rambold, William; Hass, Roland; Janssen, Katja
2010-07-01
In October 2009, an interdisciplinary centre for fibre spectroscopy and sensing, innoFSPEC Potsdam, has been established as joint initiative of the Astrophysikalisches Institut Potsdam (AIP) and the Physical Chemistry group of Potsdam University (UPPC), Germany. The centre focuses on fundamental research in the two fields of fibre-coupled multi-channel spectroscopy and optical fibre-based sensing. Thanks to its interdisciplinary approach, the complementary methodologies of astrophysics on the one hand, and physical chemistry on the other hand, are expected to spawn synergies that otherwise would not normally become available in more standard research programmes. innoFSPEC Potsdam targets future innovations for next generation astrophysical instrumentation, environmental analysis, manufacturing control and process analysis, medical diagnostics, non-invasive imaging spectroscopy, biopsy, genomics/proteomics, high throughput screening, and related applications.
Gemmell, M. A.
1968-01-01
An assessment was made of the effectiveness of the generally accepted methods recommended for controlling hydatid disease during the course of a field-trial, initiated in 1943 in an isolated region of New Zealand. The results obtained during the first 21 years are described. Basically, the trial was an attempt to compare the effectiveness of a general public health educational programme and an anthelmintic programme using arecoline hydrobromide for treatment of dogs with that of a specific educational programme using this compound as a diagnostic agent. Arecoline hydrobromide was found to be too uncertain in its action to be of practical value as an anthelmintic. The development of diagnostic techniques, described in this paper, made it possible to use the compound for diagnostic purposes and thus for educational purposes, since each dog could be examined for tapeworms in the presence of the owner. Using changes in the annual prevalence rate in sheep of the cysts of E. granulosus and those of T. hydatigena as the principal indicators, the conclusion has been reached that the specific diagnostic approach achieved more success than the general educational and treatment programme. The principal reason for this appears to be that the former approach induced a greater awareness in owners of the need for strict management to prevent dogs gaining access to infective raw offal than that stimulated in the community when the dogs were dosed but not examined. ImagesFIG. 2FIG. 4FIG. 5 PMID:5303843
Lussiana, Cristina
2016-01-01
The idea of a private sector subsidy programme of artemisinin-based combination therapies (ACTs) was first proposed in 2004. Since then, several countries around the world have hosted pilot projects or programmes on subsidized ACTs and/or the Affordable Medicines Facility-malaria programme (AMFm). Overall the private sector subsidy programmes of ACTs have been effective in increasing availability of ACTs in the private sector and driving down average prices but struggled to crowd out antimalarial monotherapies. The results obtained from this ambitious strategy should inform policy makers in the designing of future interventions aimed to control malaria morbidity and mortality. Among the interventions recently proposed, a subsidy of rapid diagnostic tests (RDTs) in the private sector has been recommended by governments and international donors to cope with over-treatment with ACTs and to delay the emergence of resistance to artemisinin. In order to improve the cost-effectiveness of co-paid RDTs, we should build on the lessons we learned from almost 10 years of private sector subsidy programmes of ACTs in malaria-endemic countries. PMID:25862732
Kotlicka-Antczak, Magdalena; Pawełczyk, Tomasz; Rabe-Jabłońska, Jolanta; Pawełczyk, Agnieszka
2015-08-01
To present the activities of the first early intervention centre in Poland and the Programme of Recognition and Therapy (PORT) run by the centre. An overview of the admission process, diagnostic procedures and therapeutic interventions offered to individuals with an at-risk mental state. The PORT programme, developed in 2010, included 81 individuals, aged 15-29 years so far. The diagnostic procedures consists of evaluation of symptoms with the use of the Comprehensive Assessment of At-Risk Mental State (CAARMS), assessment of premorbid and current personality traits and the evaluation of cognitive functions. Therapeutic interventions include cognitive behavioural therapy, diet supplementation with omega-3 fatty acids and pharmacological treatment. Overall rate of conversion into psychosis within the years 2010-2103 was 18.5%. The programme has also been a source of research in the field of early psychosis. The PORT programme enables young people with an ARMS an easy access to the specialized service offering treatment tailored to their specific needs. © 2014 Wiley Publishing Asia Pty Ltd.
Revealing the Effects of Cognitive Education Programmes through Dynamic Assessment
ERIC Educational Resources Information Center
Tzuriel, David
2011-01-01
The major objective of this paper is to demonstrate the effectiveness of dynamic assessment (DA) in revealing outcomes of cognitive education programmes. Three programmes based on "mediated learning experience" theory are reviewed: "Feuerstein's Instrumental Enrichment", "Bright Start", and "Peer Mediation with…
ERIC Educational Resources Information Center
Scheeringa, Michael S.; Haslett, Nancy
2010-01-01
The need to assess Diagnostic and Statistical Manual, Fourth Edition (DSM-IV) disorders in children younger than 7 years of age has intensified as clinical efforts to diagnose and treat this population have increased, and clinical research on psychopathology has advanced. A new diagnostic instrument for young children was created, the Diagnostic…
2010-08-12
Strategies to Enhance Online Learning Teams Team Assessment and Diagnostics Instrument and Agent-based Modeling Tristan E. Johnson, Ph.D. Learning ...REPORT DATE AUG 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Strategies to Enhance Online Learning ...TeamsTeam Strategies to Enhance Online Learning Teams: Team Assessment and Diagnostics Instrument and Agent-based Modeling 5a. CONTRACT NUMBER 5b. GRANT
Bosnjak, J; Ciraj-Bjelac, O; Strbac, B
2008-01-01
Application of a quality control (QC) programme is very important when optimisation of image quality and reduction of patient exposure is desired. QC surveys of diagnostics imaging equipment in Republic of Srpska (entity of Bosnia and Herzegovina) has been systematically performed since 2001. The presented results are mostly related to the QC test results of X-ray tubes and generators for diagnostic radiology units in 92 radiology departments. In addition, results include workplace monitoring and usage of personal protective devices for staff and patients. Presented results showed the improvements in the implementation of the QC programme within the period 2001--2005. Also, more attention is given to appropriate maintenance of imaging equipment, which was one of the main problems in the past. Implementation of a QC programme is a continuous and complex process. To achieve good performance of imaging equipment, additional tests are to be introduced, along with image quality assessment and patient dosimetry. Training is very important in order to achieve these goals.
Daniel, Yvonne A; Henthorn, Joan
2016-12-01
To determine (i) if electrospray mass spectrometry-mass spectrometry with the SpOtOn Diagnostics Ltd reagent kit for sickle cell screening could be integrated into the English newborn screening programme, under routine screening conditions, and provide mass spectrometry-mass spectrometry results which match existing methods, and (ii) if common action values could be set for all manufacturers in the study, for all assessed haemoglobins, to indicate which samples require further investigation. Anonymised residual blood spots were analysed using the SpOtOn reagent kit as per manufacturer's instructions, in parallel with existing techniques at four laboratories. Mass spectrometry-mass spectrometry instrumentation at Laboratories A and B was AB Sciex (Warrington, UK) AP4000, and at Laboratories C and D, Waters Micromass (Manchester, UK), Xevo TQMS and Premier, respectively. There were 23,898 results accepted from the four laboratories. Excellent specificity at 100% sensitivity was observed for haemoglobin S, haemoglobin C, haemoglobin E and haemoglobin O Arab . A common action value was not possible for Hb C, but action values were set by manufacturer. The two haemoglobin D Punjab cases at Laboratory D were not detected using the common action value. Conversely, false-positive results with haemoglobin D Punjab were a problem at the remaining three laboratories. This multicentre study demonstrates that it is possible to implement mass spectrometry-mass spectrometry into an established screening programme while maintaining consistency with existing methods for haemoglobinopathy screening. However, one of the instruments investigated cannot be recommended for use with this application. © The Author(s) 2016.
Developing energy and momentum conceptual survey (EMCS) with four-tier diagnostic test items
NASA Astrophysics Data System (ADS)
Afif, Nur Faadhilah; Nugraha, Muhammad Gina; Samsudin, Achmad
2017-05-01
Students' conceptions of work and energy are important to support the learning process in the classroom. For that reason, a diagnostic test instrument is needed to diagnose students' conception of work and energy. As a result, the researcher decided to develop Energy and Momentum Conceptual Survey (EMCS) instrument test into four-tier test diagnostic items. The purpose of this research is organized as the first step of four-tier test-formatted EMCS development as one of diagnostic test instruments on work and Energy. The research method used the 4D model (Defining, Designing, Developing and Disseminating). The instrument developed has been tested to 39 students in one of Senior High Schools. The resulting research showed that four-tier test-formatted EMCS is able to diagnose students' conception level of work and energy concept. It can be concluded that the development of four-tier test-formatted EMCS is one of potential diagnostic test instruments that able to obtain the category of students who understand concepts, misconceptions and do not understand about Work and Energy concept at all.
Review of the role of NICE in promoting the adoption of innovative cardiac technologies.
Groves, Peter H; Pomfrett, Chris; Marlow, Mirella
2018-05-17
The National Institute for Health and Care Excellence (NICE) Medical Technologies Evaluation Programme (MTEP) promotes the adoption of innovative diagnostic and therapeutic technologies into National Health Service (NHS) clinical practice through the publication of guidance and briefing documents. Since the inception of the programme in 2009, there have been 7 medical technologiesguidance, 3 diagnostics guidance and 23 medtechinnovation briefing documents published that are relevant to the heart and circulation. Medical technologies guidance is published by NICE for selected single technologies if they offer plausible additional benefits to patients and the healthcare system. Diagnostic guidance is published for diagnostic technologies if they have the potential to improve health outcomes, but if their introduction may be associated with an increase in overall cost to the NHS. Medtechinnovation briefings provide evidence-based advice to those considering the implementation of new medical devices or diagnostic technologies. This review provides reference to all of the guidance and briefing medical technology documents that NICE has published that are relevant to the heart and circulation and reflect on their diverse recommendations. The interaction of MTEP with other NICE programmes is integral to its effectiveness and the means by which consistency is ensured across the different NICE programmes is described. The importance of the input of clinical experts from the cardiovascular professional community and the engagement by NICE with cardiovascular professional societies is highlighted as being fundamental to ensuring the quality of guidance outputs as well as to promoting their implementation and adoption. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Tang, Rongying; Prosser, Debra O.; Love, Donald R.
2016-01-01
The increasing diagnostic use of gene sequencing has led to an expanding dataset of novel variants that lie within consensus splice junctions. The challenge for diagnostic laboratories is the evaluation of these variants in order to determine if they affect splicing or are merely benign. A common evaluation strategy is to use in silico analysis, and it is here that a number of programmes are available online; however, currently, there are no consensus guidelines on the selection of programmes or protocols to interpret the prediction results. Using a collection of 222 pathogenic mutations and 50 benign polymorphisms, we evaluated the sensitivity and specificity of four in silico programmes in predicting the effect of each variant on splicing. The programmes comprised Human Splice Finder (HSF), Max Entropy Scan (MES), NNSplice, and ASSP. The MES and ASSP programmes gave the highest performance based on Receiver Operator Curve analysis, with an optimal cut-off of score reduction of 10%. The study also showed that the sensitivity of prediction is affected by the level of conservation of individual positions, with in silico predictions for variants at positions −4 and +7 within consensus splice sites being largely uninformative. PMID:27313609
Promoting the hydrostatic conceptual change test (HCCT) with four-tier diagnostic test item
NASA Astrophysics Data System (ADS)
Purwanto, M. G.; Nurliani, R.; Kaniawati, I.; Samsudin, A.
2018-05-01
Hydrostatic Conceptual Change Test (HCCT) is a diagnostic test instrument to identify students’ conception on Hydrostatic field. It is very important to support the learning process in the classroom. Based on that point of view, the researcher decided to develop HCCT instrument test into four-tier test diagnostic items. The resolve of this research is planned as the first step of four-tier test-formatted HCCT development as one of investigative test instrument on Hydrostatic. The research method used the 4D model which has four comprehensive steps: 1) defining, 2) designing, 3) developing and 4) disseminating. The instrument developed has been tried to 30 students in one of senior high schools. The data showed that four-tier- test-formatted HCCT is able to identify student’s conception level of Hydrostatic. In conclusion, the development of four-tier test-formatted HCCT is one of potential diagnostic test instrument that able to classify the category of students who misconception, no understanding, understanding, partial understanding and no codeable about concept of Hydrostatic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Theys, M.
1994-05-06
Beamlet is a high power laser currently being built at Lawrence Livermore National Lab as a proof of concept for the National Ignition Facility (NIF). Beamlet is testing several areas of laser advancements, such as a 37cm Pockels cell, square amplifier, and propagation of a square beam. The diagnostics on beamlet tell the operators how much energy the beam has in different locations, the pulse shape, the energy distribution, and other important information regarding the beam. This information is being used to evaluate new amplifier designs, and extrapolate performance to the NIF laser. In my term at Lawrence Livermore Nationalmore » Laboratory I have designed and built a diagnostic, calibrated instruments used on diagnostics, setup instruments, hooked up communication lines to the instruments, and setup computers to control specific diagnostics.« less
NASA Astrophysics Data System (ADS)
Sanz, D.; Ruiz, M.; Castro, R.; Vega, J.; Afif, M.; Monroe, M.; Simrock, S.; Debelle, T.; Marawar, R.; Glass, B.
2016-04-01
To aid in assessing the functional performance of ITER, Fission Chambers (FC) based on the neutron diagnostic use case deliver timestamped measurements of neutron source strength and fusion power. To demonstrate the Plant System Instrumentation & Control (I&C) required for such a system, ITER Organization (IO) has developed a neutron diagnostics use case that fully complies with guidelines presented in the Plant Control Design Handbook (PCDH). The implementation presented in this paper has been developed on the PXI Express (PXIe) platform using products from the ITER catalog of standard I&C hardware for fast controllers. Using FlexRIO technology, detector signals are acquired at 125 MS/s, while filtering, decimation, and three methods of neutron counting are performed in real-time via the onboard Field Programmable Gate Array (FPGA). Measurement results are reported every 1 ms through Experimental Physics and Industrial Control System (EPICS) Channel Access (CA), with real-time timestamps derived from the ITER Timing Communication Network (TCN) based on IEEE 1588-2008. Furthermore, in accordance with ITER specifications for CODAC Core System (CCS) application development, the software responsible for the management, configuration, and monitoring of system devices has been developed in compliance with a new EPICS module called Nominal Device Support (NDS) and RIO/FlexRIO design methodology.
ERIC Educational Resources Information Center
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E.; Baron-Cohen, Simon; Brayne, Carol
2015-01-01
Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not…
ERIC Educational Resources Information Center
Heredia, Keily; Xu, Xiaoying; Lewis, Jennifer E.
2012-01-01
The Particulate Nature of Matter and Chemical Bonding Diagnostic Instrument (Othman J., Treagust D. F. and Chandrasegaran A. L., (2008), "Int. J. Sci. Educ.," 30(11), 1531-1550) is used to investigate college students' understanding of two chemistry concepts: particulate nature of matter and chemical bonding. The instrument, originally…
Science and Technology Review October/November 2009
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bearinger, J P
2009-08-21
This month's issue has the following articles: (1) Award-Winning Collaborations Provide Solutions--Commentary by Steven D. Liedle; (2) Light-Speed Spectral Analysis of a Laser Pulse--An optical device inspects and stops potentially damaging laser pulses; (3) Capturing Waveforms in a Quadrillionth of a Second--The femtoscope, a time microscope, improves the temporal resolution and dynamic range of conventional recording instruments; (4) Gamma-Ray Spectroscopy in the Palm of Your Hand--A miniature gamma-ray spectrometer provides increased resolution at a reduced cost; (5) Building Fusion Targets with Precision Robotics--A robotic system assembles tiny fusion targets with nanometer precision; (6) ROSE: Making Compiler Technology More Accessible--An open-sourcemore » software infrastructure makes powerful compiler techniques available to all programmers; (7) Restoring Sight to the Blind with an Artificial Retina--A retinal prosthesis could restore vision to people suffering from eye diseases; (8) Eradicating the Aftermath of War--A remotely operated system precisely locates buried land mines; (9) Compact Alignment for Diagnostic Laser Beams--A smaller, less expensive device aligns diagnostic laser beams onto targets; and (10) Securing Radiological Sources in Africa--Livermore and other national laboratories are helping African countries secure their nuclear materials.« less
A travelling standard for radiopharmaceutical production centres in Italy
NASA Astrophysics Data System (ADS)
Capogni, M.; de Felice, P.; Fazio, A.
Short-lived radionuclides, γ, β+ and/or β- emitters, such as 18F, and 99mTc, particularly useful for nuclear medicine applications, both diagnostic and in radiotherapy, can be produced with high-specific activity in a small biomedical cyclotron or by a radionuclide generator. While [18F]Fludeoxyglucose ([18F]FDG) is a widely used radiopharmaceutical for positron emission tomography, the development of innovative diagnostic techniques and therapies involves the use of new radio-labelled molecules and emerging radionuclides, such as 64Cu and 124I. During the last 3 years, an extensive supply of [18F]FDG was started by many production sites in Italy, and new radiopharmaceuticals are being studied for future nuclear medical applications. Therefore, a special nuclear medicine research programme for primary standard development and transferral to the end-users has been carried out by the ENEA-INMRI. Because of the short half-lives of these nuclides, a portable well-type ionisation chamber was established as a secondary travelling standard. This device has been calibrated and transported to the radiopharmaceutical production centres in Italy where the local instrumentation, typically radionuclide calibrators, has been calibrated by a simple comparison, with an uncertainty level lower than 2%.
NASA Astrophysics Data System (ADS)
Briois, Christelle; Lebreton, Jean-Pierre; Szopa, Cyril; Thirkell, Laurent; Aradj, Kenzi; Bouabdellah, Abdel; Boukrara, Amirouche; Carrasco, Nathalie; Chalumeau, Gilles; Chapelon, Olivier; Colin, Fabrice; Cottin, Hervé; Engrand, Cécile; Grand, Noel; Kukui, Alexandre; Pennanech, Cyril; Thissen, Roland; Vuitton, Véronique; Zapf, Pascal; Makarov, Alexander
2014-05-01
Mass spectrometry has been used for years in space exploration to characterise the chemical composition of solar system bodies and their environment. Because of the harsh constraints imposed to the space probe instruments, their mass resolution is quite limited compared to laboratory instruments, sometimes leading to significant limitations in the treatment of the data collected with this type of instrumentation. Future in situ solar system exploration missions would significantly benefit from High Resolution Mass Spectrometry (HRMS). For a few years, 5 French laboratories (LPC2E, IPAG, LATMOS, LISA, CSNSM) involved in the chemical investigation of solar system bodies formed a Consortium to develop HRMS for future space exploration, based on the use of the Orbitrap technology (C. Briois et al., 2014, to be submitted). This development is carried out in the frame of a Research and Technology (R&T) development programme partly funded by the French Space Agency (CNES). The work is undertaken in close collaboration with the Thermo Fisher Scientific Company, which commercialises Orbitrap-based laboratory instruments. The R&T activities are currently concentrating on the core elements of the Orbitrap analyser that are required to reach a sufficient maturity level for allowing design studies of future space instruments. We are indeed pursuing, within international collaborations, the definition of several instrument concepts based on the core elements that are subject of our R&T programme. In this talk, we briefly discuss science applications for future orbitrap-based HRMS space instruments. We highlight present results of our R&T programme.
ERIC Educational Resources Information Center
MacCormac, Aoife; O'Brien, Emma; O'Kennedy, Richard
2011-01-01
This paper describes the development of a taught Master's course in biomedical diagnostics using a novel multi-disciplinary approach. This course, the first of its kind in Ireland, covers the science and technology underlying the development of medical diagnostic devices that detect early markers of diseases such as cancer. The ethical impact of…
Diagnostic instruments for behavioural addiction: an overview
Albrecht, Ulrike; Kirschner, Nina Ellen; Grüsser, Sabine M.
2007-01-01
In non-substance-related addiction, the so-called behavioural addiction, no external psychotropic substances are consumed. The psychotropic effect consists of the body’s own biochemical processes induced only by excessive activities. Until recently, knowledge was limited with respect to clinically relevant excessive reward-seeking behaviour, such as pathological gambling, excessive shopping and working which meet diagnostic criteria of dependent behaviour. To date, there is no consistent concept for diagnosis and treatment of excessive reward-seeking behaviour, and its classification is uncertain. Therefore, a clear conceptualization of the so-called behavioural addictions is of great importance. The use of adequate diagnostic instruments is necessary for successful therapeutical implications. This article provides an overview of the current popular diagnostic instruments assessing the different forms of behavioural addiction. Especially in certain areas there are only few valid and reliable instruments available to assess excessive rewarding behaviours that fulfill the criteria of addiction. PMID:19742294
ERIC Educational Resources Information Center
Mazefsky, Carla A.; Oswald, Donald P.
2006-01-01
Recent years have seen a surge of interest in assessment instruments for diagnosing autism in children. Instruments have generally been developed and evaluated from a research perspective. The Autism Diagnostic Observation Schedule-Generic (ADOS-G), Autism Diagnostic Interview-Revised (ADI-R), and Gilliam Autism Rating Scale (GARS) have received…
Engkvist, I-L; Eklund, J; Krook, J; Björkman, M; Sundin, E; Svensson, R; Eklund, M
2010-05-01
Recycling is a new and developing industry, which has only been researched to a limited extent. This article describes the development and use of instruments for data collection within a multidisciplinary research programme "Recycling centres in Sweden - working conditions, environmental and system performance". The overall purpose of the programme was to form a basis for improving the function of recycling centres with respect to these three perspectives and the disciplines of: ergonomics, safety, external environment, and production systems. A total of 10 instruments were developed for collecting data from employees, managers and visitors at recycling centres, including one instrument for observing visitors. Validation tests were performed in several steps. This, along with the quality of the collected data, and experience from the data collection, showed that the instruments and methodology used were valid and suitable for their purpose. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
An Assessment of a Technology in Music Programme. Technical Report 91-2, Revised Version.
ERIC Educational Resources Information Center
Clarkson, Austin E.; Pegley, Karen
An innovative intermediate music programme was instituted at an elementary school in a middle class suburban area in Canada. The music teacher at the school designed a unique curriculum, the Technology in Music Programme (TIMP), for a classroom equipped with microcomputers, sequencers, drum machines, music instrument digital interface (MIDI)…
Charman, Tony; Gotham, Katherine
2012-01-01
Background and Scope Significant progress has been made over the past two decades in the development of screening and diagnostic instruments for autism spectrum disorders (ASD). This article reviews this progress, including recent innovations, focussing on those instruments for which the strongest research data on validity exists, and then turns to addressing issues arising from their use in clinical settings. Findings Research studies have evaluated the ability of screens to prospectively identify cases of ASD in population-based and clinically-referred samples, as well as the accuracy of diagnostic instruments to map onto ‘gold standard’ clinical best estimate diagnosis. However, extension of the findings to clinical services must be done with caution, with a full understanding that instrument properties are sample-specific. Furthermore, we are limited by the lack of a true test for ASD, which remains a behaviourally-defined disorder. In addition screening and diagnostic instruments help clinicians least in the cases where they are most in want of direction, since their accuracy will always be lower for marginal cases. Conclusion Instruments help clinicians to collect detailed, structured information and increase accuracy and reliability of referral for in-depth assessment and recommendations for support, but further research is needed to refine their effective use in clinical settings. PMID:23539140
Leadership scheme to develop the careers of talented candidates.
Lynas, Karen
2012-02-01
The Top Leaders programme supports career development by identifying talented staff and equipping them with a range of management skills and approaches. The programme uses a diagnostic test to help candidates assess their strengths, leadership styles and development needs, and offers them 360 degrees feedback. This enables them to identify areas they need to develop to be effective and supportive leaders. Two case studies illustrate the programme in action.
Lussiana, Cristina
2016-09-01
The idea of a private sector subsidy programme of artemisinin-based combination therapies (ACTs) was first proposed in 2004. Since then, several countries around the world have hosted pilot projects or programmes on subsidized ACTs and/or the Affordable Medicines Facility-malaria programme (AMFm). Overall the private sector subsidy programmes of ACTs have been effective in increasing availability of ACTs in the private sector and driving down average prices but struggled to crowd out antimalarial monotherapies. The results obtained from this ambitious strategy should inform policy makers in the designing of future interventions aimed to control malaria morbidity and mortality. Among the interventions recently proposed, a subsidy of rapid diagnostic tests (RDTs) in the private sector has been recommended by governments and international donors to cope with over-treatment with ACTs and to delay the emergence of resistance to artemisinin. In order to improve the cost-effectiveness of co-paid RDTs, we should build on the lessons we learned from almost 10 years of private sector subsidy programmes of ACTs in malaria-endemic countries. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
Morrone, Doralba; Giordano, Livia; Artuso, Franca; Bernardi, Daniela; Fedato, Chiara; Frigerio, Alfonso; Giorgi, Daniela; Naldoni, Carlo; Saguatti, Gianni; Severi, Daniela; Taffurelli, Mario; Terribile, Daniela; Ventura, Leonardo; Bucchi, Lauro
2017-01-01
In Italy, due to increasing healthcare budget and staff shortages, the recently created regional mammography screening programmes were established under worse radiology practice quality criteria than the previously created programmes. Using available data from a national questionnaire survey conducted at the end of 2013 and involving 222 responder radiologists, we compared the main professional quality standards of radiologists working in the screening programmes established during the period 2000-2012 with those working in the screening programmes created from 1990 to 1999. The former reported more years of clinical experience in breast imaging and a greater clinical mammogram reading volume than the latter. Conversely, they dedicated less working time to breast imaging, were less likely to participate in the diagnostic assessment of screen-detected lesions, to work in large-staffed screening centres, and to have a screening and a total mammogram reading volume (SMRV and TMRV) ≥ 5000 per year. The level of most professional quality criteria of Italian mammography screening radiologists has decreased over time. As SMRV and TMRV are important predictors of diagnostic accuracy, we can expect a lower interpretation performance of radiologists working in the recently created screening programmes.
Continuing evolution of in-vitro diagnostic instrumentation
NASA Astrophysics Data System (ADS)
Cohn, Gerald E.
2000-04-01
The synthesis of analytical instrumentation and analytical biochemistry technologies in modern in vitro diagnostic instrumentation continues to generate new systems with improved performance and expanded capability. Detection modalities have expanded to include multichip modes of fluorescence, scattering, luminescence and reflectance so as to accommodate increasingly sophisticated immunochemical and nucleic acid based reagent systems. The time line graph of system development now extends from the earliest automated clinical spectrophotometers through molecule recognition assays and biosensors to the new breakthroughs of biochip and DNA diagnostics. This brief review traces some of the major innovations in the evolution of system technologies and previews the conference program.
The impact of a model-based clinical regional registry for attention-deficit hyperactivity disorder.
Zanetti, Michele; Cartabia, Massimo; Didoni, Anna; Fortinguerra, Filomena; Reale, Laura; Mondini, Matteo; Bonati, Maurizio
2017-09-01
This article describes the development and clinical impact of the Italian Regional ADHD Registry, aimed at collecting and monitoring diagnostic and therapeutic pathways of care for attention-deficit hyperactivity disorder children and adolescents, launched by the Italian Lombardy Region in June 2011. In particular, the model-based software used to run the registry and manage clinical care data acquisition and monitoring, is described. This software was developed using the PROSAFE programme, which is already used for data collection in many Italian intensive care units, as a stand-alone interface case report form. The use of the attention-deficit hyperactivity disorder regional registry led to an increase in the appropriateness of the clinical management of all patients included in the registry, proving to be an important instrument in ensuring an appropriate healthcare strategy for children and adolescents with attention-deficit/hyperactivity disorder.
Diagnostic work-up and loss of tuberculosis suspects in Jogjakarta, Indonesia.
Ahmad, Riris Andono; Matthys, Francine; Dwihardiani, Bintari; Rintiswati, Ning; de Vlas, Sake J; Mahendradhata, Yodi; van der Stuyft, Patrick
2012-02-15
Early and accurate diagnosis of pulmonary tuberculosis (TB) is critical for successful TB control. To assist in the diagnosis of smear-negative pulmonary TB, the World Health Organisation (WHO) recommends the use of a diagnostic algorithm. Our study evaluated the implementation of the national tuberculosis programme's diagnostic algorithm in routine health care settings in Jogjakarta, Indonesia. The diagnostic algorithm is based on the WHO TB diagnostic algorithm, which had already been implemented in the health facilities. We prospectively documented the diagnostic work-up of all new tuberculosis suspects until a diagnosis was reached. We used clinical audit forms to record each step chronologically. Data on the patient's gender, age, symptoms, examinations (types, dates, and results), and final diagnosis were collected. Information was recorded for 754 TB suspects; 43.5% of whom were lost during the diagnostic work-up in health centres, 0% in lung clinics. Among the TB suspects who completed diagnostic work-ups, 51.1% and 100.0% were diagnosed without following the national TB diagnostic algorithm in health centres and lung clinics, respectively. However, the work-up in the health centres and lung clinics generally conformed to international standards for tuberculosis care (ISTC). Diagnostic delays were significantly longer in health centres compared to lung clinics. The high rate of patients lost in health centres needs to be addressed through the implementation of TB suspect tracing and better programme supervision. The national TB algorithm needs to be revised and differentiated according to the level of care.
Zhang, J-F; Xu, J; Bergquist, R; Yu, L-L; Yan, X-L; Zhu, H-Q; Wen, L-Y
2016-01-01
Schistosomiasis, caused by Schistosoma japonicum infection to human, has a documented history of more than 2100years in The People's Republic of China. In spite of great progress in controlling the disease, it is still one of the most serious parasitic diseases in the country. The study and use of diagnostic techniques play an important role in the targeting of chemotherapy that has been continuously applied in the national schistosomiasis control programme for several decades. This paper reviews the development and application of parasitological, immunodiagnostic and molecular diagnostic technology for S. japonicum in The People's Republic of China with a brief mention of diagnostic imagery, such as ultrasound and radiology. When analysing the efficacy and performance characteristics of the main diagnostic techniques in current use, it becomes apparent that approaches that worked well in the past are less suitable now as successful control has shifted the endemic situation towards control and interruption of transmission. The conclusion is that a mutable approach must be adopted choosing the most appropriate diagnostic technique for each control stage (and area), thus modifying the methodology according to the prevailing diagnostic needs in terms of sensitivity and specificity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Integration of Diagnostic Microbiology in a Model of Total Laboratory Automation.
Da Rin, Giorgio; Zoppelletto, Maira; Lippi, Giuseppe
2016-02-01
Although automation has become widely utilized in certain areas of diagnostic testing, its adoption in diagnostic microbiology has proceeded much more slowly. To describe our real-world experience of integrating an automated instrument for diagnostic microbiology (Walk-Away Specimen Processor, WASPLab) within a model of total laboratory automation (TLA). The implementation process was divided into 2 phases. The former period, lasting approximately 6 weeks, entailed the installation of the WASPLab processor to operate as a stand-alone instrumentation, whereas the latter, lasting approximately 2 weeks, involved physical connection of the WASPLab with the automation. Using the WASPLab instrument in conjunction with the TLA model, we obtained a time savings equivalent to the work of 1.2 full-time laboratory technicians for diagnostic microbiology. The connection of WASPLab to TLA allowed its management by a generalist or clinical chemistry technician, with no need for microbiology skills on the part of either worker. Hence, diagnostic microbiology could be performed by the staff that is already using the TLA, extending their activities to include processing urgent clinical chemistry and hematology specimens. The time to result was also substantially improved. According to our experience, using the WASPLab instrument as part of a TLA in diagnostic microbiology holds great promise for optimizing laboratory workflow and improving the quality of testing. © American Society for Clinical Pathology, 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
ExoMars Raman laser spectrometer breadboard overview
NASA Astrophysics Data System (ADS)
Díaz, E.; Moral, A. G.; Canora, C. P.; Ramos, G.; Barcos, O.; Prieto, J. A. R.; Hutchinson, I. B.; Ingley, R.; Colombo, M.; Canchal, R.; Dávila, B.; Manfredi, J. A. R.; Jiménez, A.; Gallego, P.; Pla, J.; Margoillés, R.; Rull, F.; Sansano, A.; López, G.; Catalá, A.; Tato, C.
2011-10-01
The Raman Laser Spectrometer (RLS) is one of the Pasteur Payload instruments, within the ESA's Aurora Exploration Programme, ExoMars mission. The RLS Instrument will perform Raman spectroscopy on crushed powdered samples deposited on a small container after crushing the cores obtained by the Rover's drill system. In response to ESA requirements for delta-PDR to be held in mid 2012, an instrument BB programme has been developed, by RLS Assembly Integration and Verification (AIV) Team to achieve the Technology Readiness level 5 (TRL5), during last 2010 and whole 2011. Currently RLS instrument is being developed pending its CoDR (Conceptual Design Revision) with ESA, in October 2011. It is planned to have a fully operative breadboard, conformed from different unit and sub-units breadboards that would demonstrate the end-to-end performance of the flight representative units by 2011 Q4.
2011-01-01
Background Moving a forensic mental health patient from one level of therapeutic security to a lower level or to the community is influenced by more than risk assessment and risk management. We set out to construct and validate structured professional judgement instruments for consistency and transparency in decision making Methods Two instruments were developed, the seven-item DUNDRUM-3 programme completion instrument and the six item DUNDRUM-4 recovery instrument. These were assessed for all 95 forensic patients at Ireland's only forensic mental health hospital. Results The two instruments had good internal consistency (Cronbach's alpha 0.911 and 0.887). Scores distinguished those allowed no leave or accompanied leave from those with unaccompanied leave (ANOVA F = 38.1 and 50.3 respectively, p < 0.001). Scores also distinguished those in acute/high security units from those in medium or in low secure/pre-discharge units. Each individual item distinguished these levels of need significantly. The DUNDRUM-3 and DUNDRUM-4 correlated moderately with measures of dynamic risk and with the CANFOR staff rated unmet need (Spearman r = 0.5, p < 0.001). Conclusions The DUNDRUM-3 programme completion items distinguished significantly between levels of therapeutic security while the DUNDRUM-4 recovery items consistently distinguished those given unaccompanied leave outside the hospital and those in the lowest levels of therapeutic security. This data forms the basis for a prospective study of outcomes now underway. PMID:21722396
Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.
2015-01-01
Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra-articular disorder (sensitivity of 0.80 and specificity of 0.97). Diagnostic criteria for other common intra-articular disorders lack adequate validity for clinical diagnoses but can be used for screening purposes. Inter-examiner reliability for the clinical assessment associated with the validated DC/TMD criteria for pain-related TMD is excellent (kappa ≥ 0.85). Finally, a comprehensive classification system that includes both the common and less common TMD is also presented. The Axis II protocol retains selected original RDC/TMD screening instruments augmented with new instruments to assess jaw function as well as behavioral and additional psychosocial factors. The Axis II protocol is divided into screening and comprehensive self-report instrument sets. The screening instruments’ 41 questions assess pain intensity, pain-related disability, psychological distress, jaw functional limitations, and parafunctional behaviors, and a pain drawing is used to assess locations of pain. The comprehensive instruments, composed of 81 questions, assess in further detail jaw functional limitations and psychological distress as well as additional constructs of anxiety and presence of comorbid pain conditions. Conclusion The recommended evidence-based new DC/TMD protocol is appropriate for use in both clinical and research settings. More comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations. PMID:24482784
NASA Astrophysics Data System (ADS)
Campbell, Erin Roberts
The process of chemical education should facilitate students' construction of meaningful conceptual structures about the concepts and processes of chemistry. It is evident, however, that students at all levels possess concepts that are inconsistent with currently accepted scientific views. The purpose of this study was to examine undergraduate chemistry students' conceptions of atomic structure, chemical bonding and molecular structure. A diagnostic instrument to evaluate students' conceptions of atomic and molecular structure was developed by the researcher. The instrument incorporated multiple-choice items and reasoned explanations based upon relevant literature and a categorical summarization of student responses (Treagust, 1988, 1995). A covalent bonding and molecular structure diagnostic instrument developed by Peterson and Treagust (1989) was also employed. The ex post facto portion of the study examined the conceptual understanding of undergraduate chemistry students using descriptive statistics to summarize the results obtained from the diagnostic instruments. In addition to the descriptive portion of the study, a total score for each student was calculated based on the combination of correct and incorrect choices made for each item. A comparison of scores obtained on the diagnostic instruments by the upper and lower classes of undergraduate students was made using a t-Test. This study also examined an axiomatic assumption that an understanding of atomic structure is important in understanding bonding and molecular structure. A Pearson Correlation Coefficient, ṟ, was calculated to provide a measure of the strength of this association. Additionally, this study gathered information regarding expectations of undergraduate chemistry students' understanding held by the chemical community. Two questionnaires were developed with items based upon the propositional knowledge statements used in the development of the diagnostic instruments. Subgroups of items from the questionnaires were formed from the combination of items found to measure different aspects of a specific topic area using a reliability analysis. Average scores for the subgroups were compared to results obtained by students on the diagnostic instrument targeting the same topic area. There were no significant differences of the scores on both of the diagnostic instruments between the levels of undergraduate chemistry students. There were, however, significant differences on certain items of the diagnostic instruments between upper and lower class students. Additionally, misconceptions were identified within all levels of these undergraduate students that corresponded to previous results reported in the literature. A significant relationship was found to exist between the scores obtained on the two diagnostic instruments, as well as strong correlations between specific items and the total scores of the instruments. Response to the expectations questionnaires revealed no differences between the chemical industry and chemical academia, but did provide information concerning the chemical community's expectations of undergraduate chemistry students. Results indicate that undergraduate students majoring in chemistry have conceptions that are inconsistent with currently accepted scientific views. The findings also support the hypothesis that an understanding of the general structure of the atom and the roles played by electrons in molecular bonding and structure is important to an understanding of chemical properties and behavior.
SODI-COLLOID (Selectable Optical Diagnostics Instrument - Colloid)
2011-10-17
ISS029-E-027431 (17 Oct. 2011) --- In the International Space Station?s Destiny laboratory, Japan Aerospace Exploration Agency astronaut Satoshi Furukawa, Expedition 29 flight engineer, activates the Microgravity Science Glovebox (MSG) in preparation for work with the Selectable Optical Diagnostics Instrument ? Colloid (SODI-COLLOID) hardware.
SODI-COLLOID (Selectable Optical Diagnostics Instrument - Colloid)
2011-10-17
ISS029-E-027435 (17 Oct. 2011) --- In the International Space Station?s Destiny laboratory, Japan Aerospace Exploration Agency astronaut Satoshi Furukawa, Expedition 29 flight engineer, activates the Microgravity Science Glovebox (MSG) in preparation for work with the Selectable Optical Diagnostics Instrument ? Colloid (SODI-COLLOID) hardware.
Boettcher, Johanna; Berger, Thomas; Renneberg, Babette
2012-10-01
Numerous studies suggest that Internet-based self-help treatments are effective in treating anxiety disorders. Trials evaluating such interventions differ in their screening procedures and in the amount of clinician contact in the diagnostic assessment phase. The present study evaluates the impact of a pre-treatment diagnostic interview on the outcome of an Internet-based treatment for Social Anxiety Disorder (SAD). One hundred and nine participants seeking treatment for SAD were randomized to either an interview-group (IG, N = 53) or to a non-interview group (NIG, N = 56). All participants took part in the same 10-week cognitive-behavioural unguided self-help programme. Before receiving access to the programme, participants of the IG underwent a structured diagnostic interview. Participants of the NIG started directly with the programme. Participants in both groups showed significant and substantial improvement on social anxiety measures from pre- to post-assessment (d IG = 1.30-1.63; d NIG = 1.00-1.28) and from pre- to 4-month follow-up assessment (d IG = 1.38-1.87; d NIG = 1.10-1.21). Significant between-groups effects in favour of the IG were found on secondary outcome measures of depression and general distress (d = 0.18-0.42). These findings suggest that Internet-based self-help is effective in treating SAD, whether or not a diagnostic interview is involved. However, the pre-treatment interview seems to facilitate change on secondary outcomes such as depression and general distress.
NASA Astrophysics Data System (ADS)
Durieux, Alain; Babolat, Claude; Dureux, Pierre; Martin, Bernard
2018-04-01
This paper, "Diagnostics optiques pour la mesure de fluides critiques en micro-gravité dans les instruments ALICE et DECLIC," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.
A Versatile Planetary Radio Science Microreceiver
NASA Technical Reports Server (NTRS)
Fry, Craig D.; Rosenberg, T. J.
1999-01-01
We have developed a low-power. programmable radio "microreceiver" that combines the functionality of two science instruments: a Relative Ionospheric Opacity Meter (riometer) and a swept-frequency, VTF/HF radio spectrometer. The radio receiver, calibration noise source, data acquisition and processing, and command and control functions are all contained on a single circuit board. This design is suitable for miniaturizing as a complete flight instrument. Several of the subsystems were implemented in a field-programmable gate array (FPGA), including the receiver detector, the control logic, and the data acquisition and processing blocks. Considerable efforts were made to reduce the power consumption of the instrument, and eliminate or minimize RF noise and spurious emissions generated by the receiver's digital circuitry. A prototype instrument was deployed at McMurdo Station, Antarctica, and operated in parallel with a traditional riometer instrument for approximately three weeks. The attached paper (accepted for publication by Radio Science) describes in detail the microreceiver theory of operation, performance specifications and test results.
NASA Astrophysics Data System (ADS)
Jenness, Tim; Economou, Frossie; Cavanagh, Brad
ORAC-DR is a general purpose automatic data reduction pipeline environment. This document describes how to modify data reduction recipes and how to add new instruments. For a general overview of ORAC-DR see SUN/230. For specific information on how to reduce the data for a particular instrument, please consult the appropriate ORAC-DR instrument guide.
[work motivation -- assessment instruments and their relevance for medical care].
Fiedler, Rolf G; Ranft, Andreas; Greitemann, Bernhard; Heuft, Gereon
2005-11-01
The relevance of work motivation for medical research and healthcare, in particular rehabilitation, is described. Four diagnostic instruments in the German language are introduced which can assess work motivation using a scale system: AVEM, JDS, LMI and FBTM. Their possible application and potential usage for the clinical area are discussed. Apart from the FBTM, none of these instruments can be directly used as a general instrument in a normal medical clinical setting. Finally, a current model for work motivation (compensatory model of work motivation and volition) is presented that contains basis concepts, which are judged as important for future research questions concerning the development of motivation diagnostic instruments.
Molecular diagnostics for low resource settings
NASA Astrophysics Data System (ADS)
Weigl, Bernhard H.
2010-03-01
As traditional high quality diagnostic laboratories are not widely available or affordable in developing country health care settings, microfluidics-based point-of-care diagnostics may be able to address the need to perform complex assays in under-resourced areas. Many instrument-based as well as non-instrumented microfluidic prototype diagnostics are currently being developed. In addition to various engineering challenges, the greatest remaining issue is the search for truly low-cost disposable manufacturing methods. Diagnostics for global health, and specifically microfluidics and molecular-based low resource diagnostics, have become a very active research area over the last five years, thanks in part to new funding that became available from the Bill and Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based lab-on-a-chips for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic acid amplification have been developed as well. Regardless of platform, however, the search for truly low-cost manufacturing methods that would result in cost of goods per disposable of around US1/unit at volume remains a big challenge. This talk will give an overview over existing platform development efforts as well as present some original research in this area at PATH.
Evidence-Based Diagnosis: Incorporating Diagnostic Instruments into Clinical Practice
ERIC Educational Resources Information Center
Doss, Amanda Jensen
2005-01-01
This article is intended to serve as a practical guide for practitioners interested in incorporating evidence-based diagnosis (EBD) instruments into their clinical practices to refine the diagnostic process. Three measures are used to illustrate this process, the DISC-IV (Shaffer et al., 2000), the Schedule for Affective Disorders and…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-0258] Molecular Diagnostic Instruments With Combined Functions; Draft Guidance for Industry and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food...
Diagnostic work-up and loss of tuberculosis suspects in Jogjakarta, Indonesia
2012-01-01
Background Early and accurate diagnosis of pulmonary tuberculosis (TB) is critical for successful TB control. To assist in the diagnosis of smear-negative pulmonary TB, the World Health Organisation (WHO) recommends the use of a diagnostic algorithm. Our study evaluated the implementation of the national tuberculosis programme's diagnostic algorithm in routine health care settings in Jogjakarta, Indonesia. The diagnostic algorithm is based on the WHO TB diagnostic algorithm, which had already been implemented in the health facilities. Methods We prospectively documented the diagnostic work-up of all new tuberculosis suspects until a diagnosis was reached. We used clinical audit forms to record each step chronologically. Data on the patient's gender, age, symptoms, examinations (types, dates, and results), and final diagnosis were collected. Results Information was recorded for 754 TB suspects; 43.5% of whom were lost during the diagnostic work-up in health centres, 0% in lung clinics. Among the TB suspects who completed diagnostic work-ups, 51.1% and 100.0% were diagnosed without following the national TB diagnostic algorithm in health centres and lung clinics, respectively. However, the work-up in the health centres and lung clinics generally conformed to international standards for tuberculosis care (ISTC). Diagnostic delays were significantly longer in health centres compared to lung clinics. Conclusions The high rate of patients lost in health centres needs to be addressed through the implementation of TB suspect tracing and better programme supervision. The national TB algorithm needs to be revised and differentiated according to the level of care. PMID:22333111
Adult Education and Indigenous People: Addressing Gender in Policy and Practice
ERIC Educational Resources Information Center
Rao, Nitya; Robinson-Pant, Anna
2006-01-01
Adult education programmes developed for or by indigenous communities rarely seem to have addressed gender inequalities. Yet, compared to mainstream adult educational interventions promoting instrumental approaches to "functional literacy", such programmes often appear highly politicised, starting from a standpoint of promoting…
A programmable ISA to USB interface
NASA Astrophysics Data System (ADS)
Ribas, R. V.
2013-05-01
A programmable device to access and control ISA-standard camac instrumentation and interfacing it to the USB port of computers, is described in this article. With local processing capabilities and event buffering before sending data to the computer, the new acquisition system become much more efficient.
HÖner, Oliver; Votteler, Andreas; Schmid, Markus; Schultz, Florian; Roth, Klaus
2015-01-01
The utilisation of motor performance tests for talent identification in youth sports is discussed intensively in talent research. This article examines the reliability, differential stability and validity of the motor diagnostics conducted nationwide by the German football talent identification and development programme and provides reference values for a standardised interpretation of the diagnostics results. Highly selected players (the top 4% of their age groups, U12-U15) took part in the diagnostics at 17 measurement points between spring 2004 and spring 2012 (N = 68,158). The heterogeneous test battery measured speed abilities and football-specific technical skills (sprint, agility, dribbling, ball control, shooting, juggling). For all measurement points, the overall score and the speed tests showed high internal consistency, high test-retest reliability and satisfying differential stability. The diagnostics demonstrated satisfying factorial-related validity with plausible and stable loadings on the two empirical factors "speed" and "technical skills". The score, and the technical skills dribbling and juggling, differentiated the most among players of different performance levels and thus showed the highest criterion-related validity. Satisfactory psychometric properties for the diagnostics are an important prerequisite for a scientifically sound rating of players' actual motor performance and for the future examination of the prognostic validity for success in adulthood.
NASA Technical Reports Server (NTRS)
Oeftering, Richard C.; Bradish, Martin A.
2011-01-01
The role of synthetic instruments (SIs) for Component-Level Electronic-Assembly Repair (CLEAR) is to provide an external lower-level diagnostic and functional test capability beyond the built-in-test capabilities of spacecraft electronics. Built-in diagnostics can report faults and symptoms, but isolating the root cause and performing corrective action requires specialized instruments. Often a fault can be revealed by emulating the operation of external hardware. This implies complex hardware that is too massive to be accommodated in spacecraft. The SI strategy is aimed at minimizing complexity and mass by employing highly reconfigurable instruments that perform diagnostics and emulate external functions. In effect, SI can synthesize an instrument on demand. The SI architecture section of this document summarizes the result of a recent program diagnostic and test needs assessment based on the International Space Station. The SI architecture addresses operational issues such as minimizing crew time and crew skill level, and the SI data transactions between the crew and supporting ground engineering searching for the root cause and formulating corrective actions. SI technology is described within a teleoperations framework. The remaining sections describe a lab demonstration intended to show that a single SI circuit could synthesize an instrument in hardware and subsequently clear the hardware and synthesize a completely different instrument on demand. An analysis of the capabilities and limitations of commercially available SI hardware and programming tools is included. Future work in SI technology is also described.
Dückers, Michel L A; Wagner, Cordula; Groenewegen, Peter P
2008-08-11
In quality improvement collaboratives (QICs) teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. The exploratory methodological design included two phases: a) content development and assessment, resulting in an instrument with 15 items, and b) field testing (N = 165). Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.
Me and My Body (MAMBO): An Interactive Science Education Programme for Primary Schools
ERIC Educational Resources Information Center
Scalzo, Clare; Killard, Fiona; MacCormac, Aoife; Fryar, James; O' Brien, Emma; O'Kennedy, Richard
2008-01-01
This paper describes a novel science education initiative developed for 8-to 12-year-old children by the Biomedical Diagnostics Institute at Dublin City University, Ireland. "Me and My Body" (MAMBO) is an interactive, multi-faceted programme that enables children to explore and understand the dynamic physiological parameters of the human…
Diagnostic inertia in dyslipidaemia: results of a preventative programme in Spain.
Palazón-Bru, Antonio; Sepehri, Armina; Ramírez-Prado, Dolores; Navarro-Cremades, Felipe; Cortés, Ernesto; Rizo-Baeza, Mercedes; Gil-Guillén, Vicente Francisco
2015-01-01
Others have analysed the relationship between inadequate behaviour by healthcare professionals in the diagnosis of dyslipidaemia (diagnostic inertia) and the history of cardiovascular risk factors. However, since no study has assessed cardiovascular risk scores as associated factors, we carried out a study to quantify diagnostic inertia in dyslipidaemia and to determine if cardiovascular risk scores are associated with this inertia. In the Valencian Community (Spain), a preventive programme (cardiovascular, gynaecologic and vaccination) was started in 2003 inviting persons aged ≥40 years to undergo a health check-up at their health centre. This cross-sectional study examined persons with no known dyslipidaemia seen during the first six months of the programme (n = 16, 905) but whose total cholesterol (TC) was ≥5.17 mmol/L. Diagnostic inertia was defined as lack of follow-up to confirm/discard the dyslipidaemia diagnosis. Other variables included in the analysis were gender, history of cardiovascular risk factors/cardiovascular disease, counselling (diet/exercise), body mass index (BMI), age, blood pressure, fasting blood glucose and lipids. TC was grouped as ≥/<6.20 mmol/L. In patients without cardiovascular disease and <75/≤65 years (n = 15, 778/13, 597), the REGICOR (REgistre GIroní del COr)/SCORE (Systematic COronary Risk Evaluation) cardiovascular risk functions were used to classify risk (high/low). Inertia was quantified and the adjusted odds ratios calculated from multivariate models. In the overall sample, the rate of diagnostic inertia was 52% (95% CI [51.2-52.7]); associated factors were TC ≥ 6.20 mmol/L, high or "not measured" BMI, hypertension, smoking and higher values of fasting blood glucose, systolic blood pressure and TC. In the REGICOR sample, the rate of diagnostic inertia was 51.9% (95% CI [51.1-52.7]); associated factors were REGICOR high and high or "not measured" BMI. In the SCORE sample the rate of diagnostic inertia was 51.7% (95% CI [50.9-52.5]); associated factors were SCORE high and high or "not measured" BMI. Diagnostic inertia existed in over half the patients and was associated with a greater cardiovascular risk.
Diagnostic inertia in dyslipidaemia: results of a preventative programme in Spain
Sepehri, Armina; Ramírez-Prado, Dolores; Navarro-Cremades, Felipe; Cortés, Ernesto; Rizo-Baeza, Mercedes; Gil-Guillén, Vicente Francisco
2015-01-01
Others have analysed the relationship between inadequate behaviour by healthcare professionals in the diagnosis of dyslipidaemia (diagnostic inertia) and the history of cardiovascular risk factors. However, since no study has assessed cardiovascular risk scores as associated factors, we carried out a study to quantify diagnostic inertia in dyslipidaemia and to determine if cardiovascular risk scores are associated with this inertia. In the Valencian Community (Spain), a preventive programme (cardiovascular, gynaecologic and vaccination) was started in 2003 inviting persons aged ≥40 years to undergo a health check-up at their health centre. This cross-sectional study examined persons with no known dyslipidaemia seen during the first six months of the programme (n = 16, 905) but whose total cholesterol (TC) was ≥5.17 mmol/L. Diagnostic inertia was defined as lack of follow-up to confirm/discard the dyslipidaemia diagnosis. Other variables included in the analysis were gender, history of cardiovascular risk factors/cardiovascular disease, counselling (diet/exercise), body mass index (BMI), age, blood pressure, fasting blood glucose and lipids. TC was grouped as ≥/<6.20 mmol/L. In patients without cardiovascular disease and <75/≤65 years (n = 15, 778/13, 597), the REGICOR (REgistre GIroní del COr)/SCORE (Systematic COronary Risk Evaluation) cardiovascular risk functions were used to classify risk (high/low). Inertia was quantified and the adjusted odds ratios calculated from multivariate models. In the overall sample, the rate of diagnostic inertia was 52% (95% CI [51.2–52.7]); associated factors were TC ≥ 6.20 mmol/L, high or “not measured” BMI, hypertension, smoking and higher values of fasting blood glucose, systolic blood pressure and TC. In the REGICOR sample, the rate of diagnostic inertia was 51.9% (95% CI [51.1–52.7]); associated factors were REGICOR high and high or “not measured” BMI. In the SCORE sample the rate of diagnostic inertia was 51.7% (95% CI [50.9–52.5]); associated factors were SCORE high and high or “not measured” BMI. Diagnostic inertia existed in over half the patients and was associated with a greater cardiovascular risk. PMID:26246966
Incardona, Sandra; Serra-Casas, Elisa; Champouillon, Nora; Nsanzabana, Christian; Cunningham, Jane; González, Iveth J
2017-05-15
Malaria rapid diagnostic tests (RDTs) play a critical role in malaria case management, and assurance of quality is a key factor to promote good adherence to test results. Since 2007, the World Health Organization (WHO) and the Foundation for Innovative New Diagnostics (FIND) have coordinated a Malaria RDT Evaluation Programme, comprising a pre-purchase performance evaluation (product testing, PT) and a pre-distribution quality control of lots (lot testing, LT), the former being the basis of WHO recommendations for RDT procurement. Comprehensive information on malaria RDTs sold worldwide based on manufacturers' data and linked to independent performance data is currently not available, and detailed knowledge of procurement practices remains limited. The use of the PT/LT Programme results as well as procurement and lot verification practices were assessed through a large-scale survey, gathering product-specific RDT sales and procurement data (2011-14 period) from a total of 32 manufacturers, 12 procurers and 68 National Malaria Control Programmes (NMCPs). Manufacturers' reports showed that RDT sales had more than doubled over the four years, and confirmed a trend towards increased compliance with the WHO procurement criteria (from 83% in 2011 to 93% in 2014). Country-level reports indicated that 74% of NMCPs procured only 'WHO-compliant' RDT products, although procurers' transactions datasets revealed a surprisingly frequent overlap of different products and even product types (e.g., Plasmodium falciparum-only and Plasmodium-pan) in the same year and country (60 and 46% of countries, respectively). Importantly, the proportion of 'non-complying' (i.e., PT low scored or not evaluated) products was found to be higher in the private health care sector than in the public sector (32% vs 5%), and increasing over time (from 22% of private sector sales in 2011 to 39% in 2014). An estimated 70% of the RDT market was covered by the LT programme. The opinion about the PT/LT Programmes was positive overall, and quality of RDTs as per the PT Programme was rated as the number one procurement criteria. This survey provided in-depth information on RDT sales and procurement dynamics, including the largely unstudied private sector, and demonstrated how the WHO-FIND Programme has positively influenced procurement practices in the public sector.
What Is Available for Case Identification in Autism Research in Mainland China?
ERIC Educational Resources Information Center
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Matthews, Fiona E.; Baron-Cohen, Simon; Brayne, Carol
2013-01-01
Little is known about research on Autism Spectrum Conditions (ASC) in mainland China. The few available studies in mainland China have shown the screening and diagnostic instruments for ASC used in mainland China were different from the West. Literature on screening and diagnostic instruments and criteria were reviewed and current available…
ERIC Educational Resources Information Center
Muller, Josef, Ed.; Dietrich, Anja, Ed.
This document contains a collection of literacy program evaluation instruments from developing countries, as well as several papers describing how to use evaluation instruments to assess various types of systems. The following titles (with author or country of origin) are contained in this collection: "Designing a System of Evaluation and…
Peri, Kathy; Robinson, Elizabeth; Wilkinson, Tim; von Randow, Martin; Kiata, Liz; Parsons, John; Latham, Nancy; Parsons, Matthew; Willingale, Jane; Brown, Paul; Arroll, Bruce
2008-01-01
Objective To assess the effectiveness of an activity programme in improving function, quality of life, and falls in older people in residential care. Design Cluster randomised controlled trial with one year follow-up. Setting 41 low level dependency residential care homes in New Zealand. Participants 682 people aged 65 years or over. Interventions 330 residents were offered a goal setting and individualised activities of daily living activity programme by a gerontology nurse, reinforced by usual healthcare assistants; 352 residents received social visits. Main outcome measures Function (late life function and disability instruments, elderly mobility scale, FICSIT-4 balance test, timed up and go test), quality of life (life satisfaction index, EuroQol), and falls (time to fall over 12 months). Secondary outcomes were depressive symptoms and hospital admissions. Results 473 (70%) participants completed the trial. The programme had no impact overall. However, in contrast to residents with impaired cognition (no differences between intervention and control group), those with normal cognition in the intervention group may have maintained overall function (late life function and disability instrument total function, P=0.024) and lower limb function (late life function and disability instrument basic lower extremity, P=0.015). In residents with cognitive impairment, the likelihood of depression increased in the intervention group. No other outcomes differed between groups. Conclusion A programme of functional rehabilitation had minimal impact for elderly people in residential care with normal cognition but was not beneficial for those with poor cognition. Trial registration Australian Clinical Trials Register ACTRN12605000667617. PMID:18845605
Characterization of the Goubau line for testing beam diagnostic instruments
NASA Astrophysics Data System (ADS)
Kim, S. Y.; Stulle, F.; Sung, C. K.; Yoo, K. H.; Seok, J.; Moon, K. J.; Choi, C. U.; Chung, Y.; Kim, G.; Woo, H. J.; Kwon, J.; Lee, I. G.; Choi, E. M.; Chung, M.
2017-12-01
One of the main characteristics of the Goubau line is that it supports a low-loss, non-radiated surface wave guided by a dielectric-coated metal wire. The dominant mode of the surface wave along the Goubau line is a TM01 mode, which resembles the pattern of the electromagnetic fields induced in the metallic beam pipe when the charged particle beam passes through it. Therefore, the Goubau line can be used for the preliminary bench test and performance optimization of the beam diagnostic instruments without requiring charged particle beams from the accelerators. In this paper, we discuss the basic properties of the Goubau line for testing beam diagnostic instruments and present the initial test results for button-type beam position monitors (BPMs). The experimental results are consistent with the theoretical estimations, which indicates that Goubau line allows effective testing of beam diagnostic equipment.
A design and implementation methodology for diagnostic systems
NASA Technical Reports Server (NTRS)
Williams, Linda J. F.
1988-01-01
A methodology for design and implementation of diagnostic systems is presented. Also discussed are the advantages of embedding a diagnostic system in a host system environment. The methodology utilizes an architecture for diagnostic system development that is hierarchical and makes use of object-oriented representation techniques. Additionally, qualitative models are used to describe the host system components and their behavior. The methodology architecture includes a diagnostic engine that utilizes a combination of heuristic knowledge to control the sequence of diagnostic reasoning. The methodology provides an integrated approach to development of diagnostic system requirements that is more rigorous than standard systems engineering techniques. The advantages of using this methodology during various life cycle phases of the host systems (e.g., National Aerospace Plane (NASP)) include: the capability to analyze diagnostic instrumentation requirements during the host system design phase, a ready software architecture for implementation of diagnostics in the host system, and the opportunity to analyze instrumentation for failure coverage in safety critical host system operations.
Educational Diagnostic Assessment.
ERIC Educational Resources Information Center
Bejar, Isaac I.
1984-01-01
Approaches proposed for educational diagnostic assessment are reviewed and identified as deficit assessment and error analysis. The development of diagnostic instruments may require a reexamination of existing psychometric models and development of alternative ones. The psychometric and content demands of diagnostic assessment all but require test…
Portable devices and mobile instruments for infectious diseases point-of-care testing.
Bissonnette, Luc; Bergeron, Michel G
2017-05-01
Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.
Cotten, Steven W; Shajani-Yi, Zahra; Cervinski, Mark A; Voorhees, Timothy; Tuchman, Sascha A; Korpi-Steiner, Nichole
2018-06-06
Serum free light chain (FLC) immunoglobulins are key biomarkers that aid in the diagnosis, prognosis and assessment of treatment response in patients with plasma cell disorders (PCD). Here we investigated the transference of manufacturer's reported κFLC, λFLC and κ to λ FLC reference intervals (RI) and established de novo FLC RI and diagnostic ranges on four instruments at three academic medical centers. In addition, we also compared the classification of patient FLC results using manufacturer's versus established RIs and diagnostic ranges. CLSI EP28-A3C protocol was applied to investigate transference and establishment of FLC reference intervals on the cobas (Roche), Immage (Beckman), Optilite and SPA Plus (Binding Site). Serum κ FLC and λ FLC were measured in reference sera (N = 126) with estimation of central 95% RIs and FLC ratio diagnostic range (total range). Frequencies (%) in patient FLC results (N > 380 per institution) classified above, below or within manufacturer's versus established FLC RI were compared. Three of four instrument platforms did not exhibit acceptable transference of manufacturer's reported κFLC RI. The manufacturer's reported FLC total diagnostic range did not encompass all values observed in reference sera for any of the four platforms evaluated. Established FLC ratio diagnostic ranges reduced the frequency of patient results classified above range for three of four platforms evaluated. Transference of manufacturer's reported FLC RIs may be inappropriate for select instrument platforms. De novo establishment of FLC RIs specific to instrument platform is highly recommended in order to assure correct patient result classification. Copyright © 2017. Published by Elsevier Inc.
Shved, E F; Novikov, P I; Vlasov, A Iu
1989-01-01
Programme based on mathematical model of the process of dead body temperature changing was developed for estimation of postmortem interval. Automatic retrieval of problem solution was performed on programmable microcalculators of "Electronica MK-61" type using adaptive approach. Diagnostical accuracy in case of dead body being preserved in permanent cooling conditions is +/- 3%.
ERIC Educational Resources Information Center
San Martín, María Gimena
2018-01-01
This study seeks to examine how a supervisor scaffolds the student-teachers' learning-to-teach process in the context of one-to-one tutoring sessions in an English as a foreign language teacher education programme in Argentina. The findings indicate that scaffolding implies two main phases: a diagnostic and an intervention phase. Moreover, the…
Evaluation of a Kindergarten Diagnostic Assessment Instrument by Gender and Ethnicity.
ERIC Educational Resources Information Center
Miller-Whitehead, Marie
Prekindergarten students (n=1,137) in an ethnically and socioeconomically diverse urban public school took a kindergarten diagnostic assessment in September prior to entry into the regular kindergarten program. The assessment was a pilot version of a longer instrument that had been used at the school for several years. Results were used for…
ERIC Educational Resources Information Center
Sizoo, Bram B.; Horwitz, E. H.; Teunisse, J. P.; Kan, C. C.; Vissers, C. T. W. M.; Forceville, E. J. M.; Van Voorst, A. J. P.; Geurts, H. M.
2015-01-01
While various screening instruments for autism spectrum disorders are widely used in diagnostic assessments, their psychometric properties have not been simultaneously evaluated in the outpatient setting where these instruments are used most. In this study, we tested the Ritvo Autism Asperger Diagnostic Scale-Revised and two short versions of the…
ERIC Educational Resources Information Center
Lin, Sheau-Wen
2004-01-01
This study involved the development and application of a two-tier diagnostic test measuring students' understanding of flowering plant growth and development. The instrument development procedure had three general steps: defining the content boundaries of the test, collecting information on students' misconceptions, and instrument development.…
ERIC Educational Resources Information Center
Sesli, Ertugrul; Kara, Yilmaz
2012-01-01
This study involved the development and application of a two-tier diagnostic test for measuring students' understanding of cell division and reproduction. The instrument development procedure had three general steps: defining the content boundaries of the test, collecting information on students' misconceptions, and instrument development.…
ERIC Educational Resources Information Center
Loh, Adrian Sin Loy; Subramaniam, R.; Tan, Kim Chwee Daniel
2014-01-01
Background: The development of two-tier multiple-choice questions has permitted the diagnosis of students' understanding on various topics in the sciences as well as helped to ascertain the alternative conceptions they have. A limitation of two-tier diagnostic instruments that has been noted in the literature, but which has not been…
Cabrera-Arana, Gustavo A; Londoño-Pimienta, Jaime L; Bello-Parías, León D
2008-01-01
Validating an instrument for measuring the perceived quality of services received by people using hospitals forming part of the Colombian Ministry of Social Protection's restructuring, redesigning and modernisation programme for health-service providing networks. Sánchez and Echeverri's guidelines for validating health quality measurement scales were followed due to the lack of a valid instrument for doing this in Colombia. Conceptual synthesis led to identifying a structure of constituent indicators, domains and sub-domains regarding the perception of health service quality. A list of reactions (having a scale for categorising the replies) was analysed according to the validity of appearance, construct, criteria and utility as criteria for sensitivity and usefulness. Successive revisions and three rounds of field-trials led to producing PECASUSS, an acronym given to the instrument for measuring users' perception of health service quality (Percepción de Calidad Según Usuarios de Servicios de Salud). The guidelines effectively orientated the validation of the instrument required for measuring the perceived quality of health services received by people using hospitals forming part of the programme.
Karunakaran, Bhuvaneshwari; Tharion, Joseph; Dhawangale, Arvind Ramrao; Paul, Debjani; Mukherji, Soumyo
2018-02-01
Miniature lenses can transform commercial imaging systems, e.g., smartphones and webcams, into powerful, low-cost, handheld microscopes. To date, the reproducible fabrication of polymer lenses is still a challenge as they require controlled dispensing of viscous liquid. This paper reports a reproducible lens fabrication technique using liquid mold with programmable curvature and off-the-shelf materials. The lens curvature is controlled during fabrication by tuning the curvature of an interface of two immiscible liquids [polydimethylsiloxane (PDMS) and glycerol]. The curvature control is implemented using a visual feedback system, which includes a software-based guiding system to produce lenses of desired curvature. The technique allows PDMS lens fabrication of a wide range of sizes and focal lengths, within 20 min. The fabrication of two lens diameters: 1 and 5 mm with focal lengths ranging between 1.2 and 11 mm are demonstrated. The lens surface and bulk quality check performed using X-ray microtomography and atomic force microscopy reveal that the lenses are suitable for optical imaging. Furthermore, a smartphone microscope with ∼1.4-μm resolution is developed using a self-assembly of a single high power fabricated lens and microaperture. The lenses have various potential applications, e.g., optofluidics, diagnostics, forensics, and surveillance. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Shah, L; Rojas, M; Mori, O; Zamudio, C; Kaufman, J S; Otero, L; Gotuzzo, E; Seas, C; Brewer, T F
2017-04-01
We compared the cost-effectiveness (CE) of an active case-finding (ACF) programme for household contacts of tuberculosis (TB) cases enrolled in first-line treatment to routine passive case-finding (PCF) within an established national TB programme in Peru. Decision analysis was used to model detection of TB in household contacts through: (1) self-report of symptomatic cases for evaluation (PCF), (2) a provider-initiated ACF programme, (3) addition of an Xpert MTB/RIF diagnostic test for a single sputum sample from household contacts, and (4) all strategies combined. CE was calculated as the incremental cost-effectiveness ratio (ICER) in terms of US dollars per disability-adjusted life years (DALYs) averted. Compared to PCF alone, ACF for household contacts resulted in an ICER of $2155 per DALY averted. The addition of the Xpert MTB/RIF diagnostic test resulted in an ICER of $3275 per DALY averted within a PCF programme and $3399 per DALY averted when an ACF programme was included. Provider-initiated ACF of household contacts in an urban setting of Lima, Peru can be highly cost-effective, even including costs to seek out contacts and perform an Xpert/MTB RIF test. ACF including Xpert MTB/RIF was not cost-effective if TB cases detected had high rates of default from treatment or poor outcomes.
Chinese Postgraduate Choices When Considering a UK Business and Management Programme
ERIC Educational Resources Information Center
Manns, Yihan; Swift, Jonathan
2016-01-01
This research investigated Chinese students' decision making processes for enrolling on a postgraduate taught business and management programme in a UK university, based on structured interviews, followed by a survey of just over 450 respondents. The validity and reliability of the research instrument were assessed prior to issuing the survey.…
ERIC Educational Resources Information Center
Ng, Clarence
2017-01-01
What are the motivational differences between students who intend to continue their learning in instrumental and choral music programmes and those who intend to discontinue? Using an achievement-goal perspective, this study investigated motivation and learning intentions of Australian students who had engaged in these extra-curricular music…
ERIC Educational Resources Information Center
Tseng, Yuan-Chueh; Tsai, Chun-Yen; Hsieh, Pei-Yu; Hung, Jeng-Fung; Huang, Tai-Chu
2014-01-01
This study explores the relationship between exposure to pseudoscientific television (TV) programmes and pseudoscientific beliefs among Taiwanese university students. The "scale of attitude toward pseudoscience" instrument was used to measure the attitudes of 380 Taiwanese university students who served as subjects for the study. The…
Development of e-Career Guidance Programme for Secondary Schools in Akwa Ibom State
ERIC Educational Resources Information Center
John, Imitoro E.; Udofia, Nsikak-Abasi; Udoh, Nsisong A.; Anagbogu, Mercy A.
2016-01-01
This study developed and field tested an electronic career guidance package for secondary schools, the e-Career Guidance System. The study was an educational research and development study and thus utilised the instrumentation research design. The formative evaluation of the developed programme was carried out using the pretest-posttest…
Modifications to the synthetic aperture microwave imaging diagnostic.
Brunner, K J; Chorley, J C; Dipper, N A; Naylor, G; Sharples, R M; Taylor, G; Thomas, D A; Vann, R G L
2016-11-01
The synthetic aperture microwave imaging diagnostic has been operating on the MAST experiment since 2011. It has provided the first 2D images of B-X-O mode conversion windows and showed the feasibility of conducting 2D Doppler back-scattering experiments. The diagnostic heavily relies on field programmable gate arrays to conduct its work. Recent successes and newly gained experience with the diagnostic have led us to modify it. The enhancements will enable pitch angle profile measurements, O and X mode separation, and the continuous acquisition of 2D DBS data. The diagnostic has also been installed on the NSTX-U and is acquiring data since May 2016.
ERIC Educational Resources Information Center
Faulkner, Fiona; Fitzmaurice, Olivia; Hannigan, Ailish
2016-01-01
Every student who enrols in a degree programme involving service mathematics in the University of Limerick in Ireland is given a mathematics diagnostic test. The diagnostic test was developed due to mathematics lecturers' anxiety regarding students' mathematical competency levels. Students receive the 40 question paper-based test in their first…
Medley, S S; Donné, A J H; Kaita, R; Kislyakov, A I; Petrov, M P; Roquemore, A L
2008-01-01
An overview of the developments postcirca 1980s in the instrumentation and application of charge exchange neutral particle diagnostics on magnetic fusion energy experiments is presented. First, spectrometers that employ only electric fields and hence provide ion energy resolution but not mass resolution are discussed. Next, spectrometers that use various geometrical combinations of both electric and magnetic fields to provide both energy and mass resolutions are reviewed. Finally, neutral particle diagnostics based on utilization of time-of-flight techniques are presented.
ERIC Educational Resources Information Center
Tan, Kim Chwee Daniel; Goh, Ngoh Khang; Chia, Lian Sai; Treagust, David F.
2002-01-01
Describes the development and application of a two-tier multiple choice diagnostic instrument to assess high school students' understanding of inorganic chemistry qualitative analysis. Shows that the Grade 10 students had difficulty understanding the reactions involved in the identification of cations and anions, for example, double decomposition…
Fault diagnostic instrumentation design for environmental control and life support systems
NASA Technical Reports Server (NTRS)
Yang, P. Y.; You, K. C.; Wynveen, R. A.; Powell, J. D., Jr.
1979-01-01
As a development phase moves toward flight hardware, the system availability becomes an important design aspect which requires high reliability and maintainability. As part of continous development efforts, a program to evaluate, design, and demonstrate advanced instrumentation fault diagnostics was successfully completed. Fault tolerance designs for reliability and other instrumenation capabilities to increase maintainability were evaluated and studied.
A tangentially viewing fast ion D-alpha diagnostic for NSTX.
Bortolon, A; Heidbrink, W W; Podestà, M
2010-10-01
A second fast ion D-alpha (FIDA) installation is planned at NSTX to complement the present perpendicular viewing FIDA diagnostics. Following the present diagnostic scheme, the new diagnostic will consist of two instruments: a spectroscopic diagnostic that measures fast ion spectra and profiles at 16 radial points with 5-10 ms resolution and a system that uses a band pass filter and photomultiplier to measure changes in FIDA light with 50 kHz sampling rate. The new pair of FIDA instruments will view the heating beams tangentially. The viewing geometry minimizes spectral contamination by beam emission or edge sources of background emission. The improved velocity-space resolution will provide detailed information about neutral-beam current drive and about fast ion acceleration and transport by injected radio frequency waves and plasma instabilities.
21 CFR 886.1460 - Stereopsis measuring instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stereopsis measuring instrument. 886.1460 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1460 Stereopsis measuring instrument. (a) Identification. A stereopsis measuring instrument is a device intended to measure depth...
NASA Astrophysics Data System (ADS)
Schultz, Madeleine; Lawrie, Gwendolyn A.; Bailey, Chantal H.; Bedford, Simon B.; Dargaville, Tim R.; O'Brien, Glennys; Tasker, Roy; Thompson, Christopher D.; Williams, Mark; Wright, Anthony H.
2017-03-01
A multi-institution collaborative team of Australian chemistry education researchers, teaching a total of over 3000 first year chemistry students annually, has explored a tool for diagnosing students' prior conceptions as they enter tertiary chemistry courses. Five core topics were selected and clusters of diagnostic items were assembled linking related concepts in each topic together. An ordered multiple choice assessment strategy was adopted to enable provision of formative feedback to students through combination of the specific distractors that they chose. Concept items were either sourced from existing research instruments or developed by the project team. The outcome is a diagnostic tool consisting of five topic clusters of five concept items that has been delivered in large introductory chemistry classes at five Australian institutions. Statistical analysis of data has enabled exploration of the composition and validity of the instrument including a comparison between delivery of the complete 25 item instrument with subsets of five items, clustered by topic. This analysis revealed that most items retained their validity when delivered in small clusters. Tensions between the assembly, validation and delivery of diagnostic instruments for the purposes of acquiring robust psychometric research data versus their pragmatic use are considered in this study.
Nickel, S; Süß, W; Lorentz, C; Trojan, A
2018-06-18
Between 2001 and 2012, the health authority of Hamburg-Eimsbüttel carried out a health promotion programme for children and their parents in a disadvantaged neighbourhood called Lenzsiedlung. The programme consisted of different action fields aiming at sustainable establishment of community capacities. The research goal was the long-term assessment of community capacities with a newly developed instrument 'KEQ' (KEQ = Kapazitätsentwicklung im Quartier/capacity building in small areas/neighbourhoods). Practitioners and researchers wanted to know whether community capacities could be increased, which changes occurred during the programme and whether processes of capacity building could be maintained. Research results were also used for the continuous adjustment of the programme to community needs. Three surveys on community capacities were conducted (t1: June 2006 [including a retrospective measurement of t0: 2001]; t2: June 2008; and t3: November 2011), each directed to 40-60 stakeholders of the Lenzsiedlung. The instrument consists of five domains (participation, local leadership, available resources, networking and cooperation and health care) with a total of 51 items. For the community capacities, we found a positive trend from 2001 to 2006 supported by data from a documentary analysis over the same period of time. Then, 2006-2011 was a phase of consolidation with only slight improvements (e.g. in the particularly important domain 'health care'). The results show the feasibility of a community health promotion programme and its maintenance over a period of 10 years. However, Lenzgesund was not the sole programme in the neighbourhood during the period of observation, so that not all improvements in capacities are directly assignable to the interventions. The instrument mainly reflects the possibly one-sided perspective of the interviewed experts from the community. Copyright © 2018 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Forgione, J.; Benford, D. J.; Buchanan, E. D.; Moseley, S. H.; Rebar, J.; Shafer, R. A.
2004-01-01
Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.
NASA Astrophysics Data System (ADS)
Forgione, Joshua B.; Benford, Dominic J.; Buchanan, Ernest D.; Moseley, S. H., Jr.; Rebar, Joyce; Shafer, Richard A.
2004-10-01
Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA's Goddard Space Flight Center acquired a Mark III system and subsequently designed upgrades to suit our and our collaborators' purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided 'hooks' in the Mark III system to allow readout of signals from outside the Mark III system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.
What Do Diagnostic Reading Tests Really Diagnose?
ERIC Educational Resources Information Center
Winkley, Carol K.
A study was made of nine reading tests, including both group and individually-administered measures, which are claimed to be chiefly diagnostic. Instruments analyzed were the following: Silent Reading Diagnostic Tests (Bond, Balow, and Hoyt), Botel Reading Inventory, Durrell Analysis of Reading Difficulty, Gates-McKillop Reading Diagnostic Tests,…
21 CFR 892.1940 - Radiologic quality assurance instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic quality assurance instrument. 892.1940... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1940 Radiologic quality assurance instrument. (a) Identification. A radiologic quality assurance instrument is a device intended for medical...
NASA Astrophysics Data System (ADS)
Hofmann, Dietrich; Dittrich, Paul-Gerald; Gärtner, Claudia; Klemm, Richard
2013-03-01
Aim of the paper is the orientation of research and development on a completely new approach to innovative in-field and point of care diagnostics in industry, biology and medicine. Central functional modules are smartphones and/or smart pads supplemented by additional hardware apps and software apps. Specific examples are given for numerous practical applications concerning optodigital instrumentations. The methodical classification distinguishes between different levels for combination of hardware apps (hwapps) and software apps (swapps) with smartphones and/or smartpads. These methods are fundamental enablers for the transformation from stationary conventional laboratory diagnostics into mobile innovative in-field and point of care diagnostics. The innovative approach opens so far untapped enormous markets due to the convenience, reliability and affordability of smartphone and/or smartpad instruments. A highly visible advantage of smartphones and/or smartpads is the huge number of their distribution, their worldwide connectivity via cloud services and the experienced capability of their users for practical operations.
Towards non- and minimally instrumented, microfluidics-based diagnostic devices†
Weigl, Bernhard; Domingo, Gonzalo; LaBarre, Paul; Gerlach, Jay
2009-01-01
In many health care settings, it is uneconomical, impractical, or unaffordable to maintain and access a fully equipped diagnostics laboratory. Examples include home health care, developing-country health care, and emergency situations in which first responders are dealing with pandemics or biowarfare agent release. In those settings, fully disposable diagnostic devices that require no instrument support, reagent, or significant training are well suited. Although the only such technology to have found widespread adoption so far is the immunochromatographic rapid assay strip test, microfluidics holds promise to expand the range of assay technologies that can be performed in formats similar to that of a strip test. In this paper, we review progress toward development of disposable, low-cost, easy-to-use microfluidics-based diagnostics that require no instrument at all. We also present examples of microfluidic functional elements—including mixers, separators, and detectors—as well as complete microfluidic devices that function entirely without any moving parts and external power sources. PMID:19023463
Evaluating the Level of Degree Programmes in Higher Education: The Case of Nursing
ERIC Educational Resources Information Center
Rexwinkel, Trudy; Haenen, Jacques; Pilot, Albert
2013-01-01
The European Quality Assurance system demands that the degree programme level is represented in terms of quantitative outcomes to be valid and reliable. To meet this need the Educational Level Evaluator (ELE) was devised. This conceptually designed procedure with instrumentation aiming to evaluate the level of a degree validly and reliably still…
ERIC Educational Resources Information Center
Primeri, Emilia; Reale, Emanuela
2012-01-01
This article describes the effects of participating in European Union Framework Programmes (EUFPs) at the level of research units and researchers. We consider EUFPs as policy instruments that contribute to the Europeanisation of academic research and study the changes they produce with respect to: 1) the organisation and activities of Departments,…
ERIC Educational Resources Information Center
Adadan, Emine; Savasci, Funda
2012-01-01
This study focused on the development of a two-tier multiple-choice diagnostic instrument, which was designed and then progressively modified, and implemented to assess students' understanding of solution chemistry concepts. The results of the study are derived from the responses of 756 Grade 11 students (age 16-17) from 14 different high schools…
ERIC Educational Resources Information Center
Richards, Brian J.
2008-01-01
This article describes the development and validation of a diagnostic test of German and its integration in a programme of formative assessment during a one-year initial teacher-training course. The test focuses on linguistic aspects that cause difficulty for trainee teachers of German as a foreign language and assesses implicit and explicit…
ERIC Educational Resources Information Center
Habok, Anita
2015-01-01
School readiness evaluations are becoming increasingly popular, and their implementation has become compulsory in an increasing number of kindergartens and schools in Hungary. In recent years, Diagnostic System for Evaluating Development (DIFER), developed by Nagy et al. has been used extensively for the diagnostic study of four- to eight-year-old…
Solid motor diagnostic instrumentation. [design of self-contained instrumentation
NASA Technical Reports Server (NTRS)
Nakamura, Y.; Arens, W. E.; Wuest, W. S.
1973-01-01
A review of typical surveillance and monitoring practices followed during the flight phases of representative solid-propellant upper stages and apogee motors was conducted to evaluate the need for improved flight diagnostic instrumentation on future spacecraft. The capabilities of the flight instrumentation package were limited to the detection of whether or not the solid motor was the cause of failure and to the identification of probable primary failure modes. Conceptual designs of self-contained flight instrumentation packages capable of meeting these reqirements were generated and their performance, typical cost, and unit characteristics determined. Comparisons of a continuous real time and a thresholded hybrid design were made on the basis of performance, mass, power, cost, and expected life. The results of this analysis substantiated the feasibility of a self-contained independent flight instrumentation module as well as the existence of performance margins by which to exploit growth option applications.
[Is evidence-based assessment fact or fiction? A bibliometric analysis of three German journals].
Petermann, Franz; Schüssler, Gerhard; Glaesmer, Heide
2008-01-01
Despite the ongoing process for the development and dissemination of empirically supported treatments, little attention has been paid to the development of evidence-based diagnostics. The article aims at evaluating diagnostic procedures and instruments in current clinical research in terms of evidence-based assessment. Volumes 2006 and 2007 of three German psychological journals "Psychotherapeut," "Psychotherapie, Psychosomatik und Medizinische Psychologie," and "Zeitschrift für Psychiatrie, Psychologie und Psychotherapie" were screened for empirical reports and articles dealing with diagnostic issues. 93 articles were identified and evaluated. Most studies used psychometrically valid and established instruments for assessment. However, diagnostic interviews were relatively scarce, as were multimodal assessments. Measures used for outcome evaluation often lacked evidence of sensitivity to change. Clinical assessment to date does not meet criteria for evidence-based diagnostics. Implications for research and guideline development are discussed.
The FASES instrument development and experiment preparation for the ISS
NASA Astrophysics Data System (ADS)
Picker, Gerold; Gollinger, Klaus; Greger, Ralf; Dettmann, Jan; Winter, Josef; Dewandre, Thierry; Castiglione, Luigi; Vincent-Bonnieu, Sebastien; Liggieri, Libero; Clausse, Daniele; Antoni, Mickael
The FASES experiments target the investigation of the stability of emulsions. The main objec-tives are the study of the surfactant adsorption at the liquid / liquid interfaces, the interaction of the droplets as well as the behaviour of the liquid film between nearby drops. Particular focus is given to the dynamic droplet evolution during emulsion destabilisation. The results of the experiments shall support development of methods for the modelling of droplet size distri-butions, which are important to many industries using stable emulsions like food production, cosmetics and pharmaceutics or unstable emulsions as required for applications in waste water treatment or crude oil recovery. The development of the experimental instrumentation was initiated in 2002. The flight instru-ment hardware development was started in 2004 and finally the flight unit was completed in 2009. Currently the final flight preparation is proceeding targeting a launch to the International Space Station (ISS) with Progress 39P in September 2010. The experiment setup of the instrument is accommodated in a box type insert called Experiment Container (EC), which will be installed in the Fluid Science Laboratory part of the European Columbus module of the ISS. The EC is composed of two diagnostics instruments for the investigation of transparent and opaque liquid emulsion. The transparent emulsions will be subject to the experiment called "Investigations on drop/drop interactions in Transparent Emulsions" (ITEM). The opaque emulsion samples will be studied in the experiment called "Investigations on concentrated or opaque Emulsions and on Phase Inversions" (EMPI). The thermal conditioning unit (TCU) allows performing homogeneous thermalization, tem-perature sweeps, emulsion preparation by stirrer, and optical diagnostics with a scanning mi-croscope. The objective of the instrument is the 3D reconstruction of the emulsion droplet distribution in the liquid matrix in terms of the droplet sizes, location and their time depen-dent evolution. The TCU will be used for the stability experiment ITEM-S and the droplet freezing experiment ITEM-F. The Differential Scanning Calorimeter (DSC) will give an information about the evolution of the emulsion through the droplet size distribution and the dispersion state of the droplets within the emulsion during a controlled temperature sweep by measuring the latent heat of droplet freezing and melting during the EMPI experiments. For this purpose the calorimeter is equipped with a reference sample filled with a pure liquid matrix and a similar measurement sample filled with the specific emulsion under investigation. The differential heat flux between measurement sample and reference sample is measured with a sensitive heat flux sensor. Each instrument is serviced by a robotic sample stowage system, which accommodates in total 44 different ITEM and EMPI emulsion samples each filled with a specific composition of the emulsion. Currently the flight preparation is ongoing with particular focus on the preparation of the emulsion flight sample set and the instrument's operating parameters. The FASES flight instrument was developed by ASTRIUM Space Transportation Germany with support of RUAG Aerospace Wallisellen under ESA / ESTEC contract. The science team of FASES is supported by ESA/ESTEC (Microgravity Application Programme, AO99-052).
Modifications to the synthetic aperture microwave imaging diagnostic
Brunner, K. J.; Chorley, J. C.; Dipper, N. A.; ...
2016-09-02
The synthetic aperture microwave imaging diagnostic has been operating on the MAST experiment since 2011. It has provided the first 2D images of B-X-O mode conversion windows and showed the feasibility of conducting 2D Doppler back-scattering experiments. The diagnostic heavily relies on field programmable gate arrays to conduct its work. Recent successes and newly gained experience with the diagnostic have led us to modify it. The enhancements will enable pitch angle profile measurements, O and X mode separation, and the continuous acquisition of 2D DBS data. Finally, the diagnostic has also been installed on the NSTX-U and is acquiring datamore » since May 2016.« less
Abdad, Mohammad Yazid; Squires, Raynal C; Cognat, Sebastien; Oxenford, Christopher John
2017-01-01
Arboviruses continue to pose serious public health threats in the World Health Organization (WHO) Western Pacific Region. As such, laboratories need to be equipped for their accurate detection. In 2011, to ensure test proficiency, the WHO Regional Office for the Western Pacific piloted an external quality assessment (EQA) programme for arbovirus diagnostics. By 2016, it had grown into a global programme with participation of 96 laboratories worldwide, including 25 laboratories from 19 countries, territories and areas in the Region. The test performance of the 25 laboratories in the Region in 2016 was high with 23 (92%) reporting correct results in all specimens for dengue and chikungunya viruses. For Zika virus, 18 (72%) of the 25 laboratories reported correct results in all specimens, while seven (28%) demonstrated at least one error. When comparing iterations of this EQA programme in the Region between 2013 and 2016, the number of participating laboratories increased from 18 to 25. The first round only included dengue virus, while the latest round additionally included chikungunya, Zika and yellow fever viruses. Proficiency for molecular detection of dengue virus remained high (83–94%) over the four-year period. The observed proficiency for arbovirus diagnostics between 2013 and 2016 is an indicator of laboratory quality improvement in the Region. PMID:29051839
Galileo Avionica's technologies and instruments for planetary exploration.
Battistelli, E; Falciani, P; Magnani, P; Midollini, B; Preti, G; Re, E
2006-12-01
Several missions for planetary exploration, including comets and asteroids, are ongoing or planned by the European Space Agencies: Rosetta, Venus Express, Bepi Colombo, Dawn, Aurora and all Mars Programme (in its past and next missions) are good examples. The satisfaction of the scientific request for the mentioned programmes calls for the development of new instruments and facilities devoted to investigate the body (planet, asteroid or comet) both remotely and by in situ measurements. The paper is an overview of some instruments for remote sensing and in situ planetary exploration already developed or under study by Galileo Avionica Space & Electro-Optics B.U. (in the following shortened as Galileo Avionica) for both the Italian Space Agency (ASI) and for the European Space Agency (ESA). Main technologies and specifications are outlined; for more detailed information please refer to Galileo Avionica's web-site at: http://www.galileoavionica.com .
Hölzel, W; Baumgarten, R; Fiedler, H; Zimmermann, S
1985-12-01
The optimal utilization of the knowledge and possibilities of pathological and clinical biochemistry presumes a close cooperation between it and the clinical specialties. The common working team of the GDR Society of Internal Medicine and the GDR Society for Clinical Chemistry and Laboratory Diagnostics makes theses of the central points of the cooperation in care, education, further education and postgraduate study and in research a subject for discussion. As essential tasks in the process of medical care are regarded the balance of the examination programme standing at the disposal, the establishment of diagnostic programmes, the establishment of organisational measures, the ascertainment of a use according to indication, the guarantee of the representance of examination material, the control of plausibility and the interpretation of test results. Since the realization of the tasks to a large extent depends on the cooperation of the specialities in education, further education and postgraduate study during the further education the clinician should become acquainted with the possibilities, the limits and the prerequisites for the performance of laboratory diagnostic investigations, the clinical biochemist with the problems of medical care and the value of the laboratory diagnosis in the total process of the treatment. In the field of research the result is a necessary cooperation in the clarification of patho-biochemical mechanisms, in the search for suitable laboratory diagnostic parameters for diagnostics and control of the course as well as in the statement of the validity of laboratory diagnostic parameters and parameter combinations taking into consideration the factors expenses, benefit and risk as well as further diagnostic possibilities.
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
21 CFR 886.1425 - Lens measuring instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lens measuring instrument. 886.1425 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1425 Lens measuring instrument. (a) Identification. A lens measuring instrument is an AC-powered device intended to measure the power of lenses...
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
ERIC Educational Resources Information Center
Romine, William L.; Schaffer, Dane L.; Barrow, Lloyd
2015-01-01
We describe the development and validation of a three-tiered diagnostic test of the water cycle (DTWC) and use it to evaluate the impact of prior learning experiences on undergraduates' misconceptions. While most approaches to instrument validation take a positivist perspective using singular criteria such as reliability and fit with a measurement…
2016-09-13
NASA astronaut Kate Rubins works on Selectable Optical Diagnostics Instrument Experiment Diffusion Coefficient Mixture-3 (SODI) DCMix-3 Installation inside the station’s Microgravity Science Glovebox. The glovebox is one of the major dedicated science facilities inside the Destiny laboratory and provides a sealed environment for conducting science and technology experiments. The glovebox is particularly suited for handling hazardous materials when the crew is present.
NASA Astrophysics Data System (ADS)
Greuter, U.; Buehler, C.; Rasmussen, P.; Emmenegger, M.; Maden, D.; Koennecke, M.; Schlumpf, N.
We present the basic concept and the realization of our fully configurable data-acquisition hardware for the neutron scattering instruments at SINQ. This system allows collection of the different data entities and event-related signals generated by the various detector units. It offers a variety of synchronization options, including a time-measuring mode for time-of-flight determinations. Based on configurable logic (FPGA, CPLD), event rates up to the MHz range can be processed and transmitted to a programmable online data-reduction system (Histogram Memory). It is implemented on a commercially available VME Power PC module running a real-time operating system (VxWorks).
Bone, Daniel; Bishop, Somer; Black, Matthew P.; Goodwin, Matthew S.; Lord, Catherine; Narayanan, Shrikanth S.
2016-01-01
Background Machine learning (ML) provides novel opportunities for human behavior research and clinical translation, yet its application can have noted pitfalls (Bone et al., 2015). In this work, we fastidiously utilize ML to derive autism spectrum disorder (ASD) instrument algorithms in an attempt to improve upon widely-used ASD screening and diagnostic tools. Methods The data consisted of Autism Diagnostic Interview-Revised (ADI-R) and Social Responsiveness Scale (SRS) scores for 1,264 verbal individuals with ASD and 462 verbal individuals with non-ASD developmental or psychiatric disorders (DD), split at age 10. Algorithms were created via a robust ML classifier, support vector machine (SVM), while targeting best-estimate clinical diagnosis of ASD vs. non-ASD. Parameter settings were tuned in multiple levels of cross-validation. Results The created algorithms were more effective (higher performing) than current algorithms, were tunable (sensitivity and specificity can be differentially weighted), and were more efficient (achieving near-peak performance with five or fewer codes). Results from ML-based fusion of ADI-R and SRS are reported. We present a screener algorithm for below (above) age 10 that reached 89.2% (86.7%) sensitivity and 59.0% (53.4%) specificity with only five behavioral codes. Conclusions ML is useful for creating robust, customizable instrument algorithms. In a unique dataset comprised of controls with other difficulties, our findings highlight limitations of current caregiver-report instruments and indicate possible avenues for improving ASD screening and diagnostic tools. PMID:27090613
Bone, Daniel; Bishop, Somer L; Black, Matthew P; Goodwin, Matthew S; Lord, Catherine; Narayanan, Shrikanth S
2016-08-01
Machine learning (ML) provides novel opportunities for human behavior research and clinical translation, yet its application can have noted pitfalls (Bone et al., 2015). In this work, we fastidiously utilize ML to derive autism spectrum disorder (ASD) instrument algorithms in an attempt to improve upon widely used ASD screening and diagnostic tools. The data consisted of Autism Diagnostic Interview-Revised (ADI-R) and Social Responsiveness Scale (SRS) scores for 1,264 verbal individuals with ASD and 462 verbal individuals with non-ASD developmental or psychiatric disorders, split at age 10. Algorithms were created via a robust ML classifier, support vector machine, while targeting best-estimate clinical diagnosis of ASD versus non-ASD. Parameter settings were tuned in multiple levels of cross-validation. The created algorithms were more effective (higher performing) than the current algorithms, were tunable (sensitivity and specificity can be differentially weighted), and were more efficient (achieving near-peak performance with five or fewer codes). Results from ML-based fusion of ADI-R and SRS are reported. We present a screener algorithm for below (above) age 10 that reached 89.2% (86.7%) sensitivity and 59.0% (53.4%) specificity with only five behavioral codes. ML is useful for creating robust, customizable instrument algorithms. In a unique dataset comprised of controls with other difficulties, our findings highlight the limitations of current caregiver-report instruments and indicate possible avenues for improving ASD screening and diagnostic tools. © 2016 Association for Child and Adolescent Mental Health.
ERIC Educational Resources Information Center
Zander, Eric; Sturm, Harald; Bölte, Sven
2015-01-01
The diagnostic validity of the new research algorithms of the Autism Diagnostic Interview-Revised and the revised algorithms of the Autism Diagnostic Observation Schedule was examined in a clinical sample of children aged 18-47 months. Validity was determined for each instrument separately and their combination against a clinical consensus…
ERIC Educational Resources Information Center
Aldridge, Jill; Fraser, Barry; Ntuli, Sipho
2009-01-01
We examined the viability of using feedback from a learning environment instrument to guide improvements in the teaching practices of in-service teachers undertaking a distance-education programme. The 31 teachers involved administered a primary school version of the What Is Happening In this Class? (WIHIC-Primary) questionnaire to their 1,077…
Evaluation of the Learning to Teach for Social Justice-Beliefs Scale in an Australian Context
ERIC Educational Resources Information Center
Ginns, Paul; Loughland, Anthony; Tierney, Robert J.; Fryer, Luke; Amazan, Rose; McCormick, Alexandra
2015-01-01
A concern for social justice pervades the espoused curriculum of many pre-service teaching programmes, but the extent to which that curriculum influences the beliefs students hold is an open question. With the goal of developing an instrument suitable for evaluating such beliefs at the degree programme level, the present study analysed responses…
ERIC Educational Resources Information Center
Zhang, Weiyuan; Ng, Tak-Kay
2006-01-01
In order to build a knowledge-based society and meet the needs of lifelong education, open learning opportunities are growing at exponential rates. While such growth is commendable, there appears to be a very strong demand for distance guidance services in open education programme selection. The purpose of this study was to develop the online…
Development of new malaria diagnostics: matching performance and need.
Bell, David; Fleurent, Alessandra E; Hegg, Michael C; Boomgard, John D; McConnico, Caitlin C
2016-08-11
Despite advances in diagnostic technology, significant gaps remain in access to malaria diagnosis. Accurate diagnosis and misdiagnosis leads to unnecessary waste of resources, poor disease management, and contributes to a cycle of poverty in low-resourced communities. Despite much effort and investment, few new technologies have reached the field in the last 30 years aside from lateral flow assays. This suggests that much diagnostic development effort has been misdirected, and/or that there are fundamental blocks to introduction of new technologies. Malaria diagnosis is a difficult market; resources are broadly donor-dependent, health systems in endemic countries are frequently weak, and the epidemiology of malaria and priorities of malaria programmes and donors are evolving. Success in diagnostic development will require a good understanding of programme gaps, and the sustainability of markets to address them. Targeting assay development to such clearly defined market requirements will improve the outcomes of product development funding. Six market segments are identified: (1) case management in low-resourced countries, (2) parasite screening for low density infections in elimination programmes, (3) surveillance for evidence of continued transmission, (4) clinical research and therapeutic efficacy monitoring, (5) cross-checking for microscopy quality control, and (6) returned traveller markets distinguished primarily by resource availability. While each of these markets is potentially compelling from a public health standpoint, size and scale are highly variable and continue to evolve. Consequently, return on investment in research and development may be limited, highlighting the need for potentially significant donor involvement or the introduction of novel business models to overcome prohibitive economics. Given the rather specific applications, a well-defined set of stakeholders will need to be on board for the successful introduction and scaling of any new technology to these markets.
Teacher Support in Learning: Instrumental and Appraisal Support in Relation to Math Achievement
ERIC Educational Resources Information Center
Wong, Tracy K. Y.; Tao, Xi; Konishi, Chiaki
2018-01-01
This study explored the extent to which teachers' instrumental (i.e., tangible aid to promote learning) and appraisal support (i.e., teacher feedback) enhanced students' achievement in mathematics. Participants included 13,950 fifteen-year-old Canadian students who participated in the 2012 Programme for International Student Assessment. Based on…
ERIC Educational Resources Information Center
Burnard, Pamela; Dragovic, Tatjana
2015-01-01
This study explores the nature of the elements that co-influence collaborative creativity in nd the intrinsic potential for enhancing pupil wellbeing as evidenced in a particular secondary-school (extra-curricular) group instrumental programme "Percussion 1." Wenger's Community of Practice (CoP) and Engestrom's Activity Theory (AT)…
The Fabrications and Travels of a Knowledge-Policy Instrument
ERIC Educational Resources Information Center
Carvalho, Luis Miguel
2012-01-01
This article sets forth the main elements of the conceptual framework for the overall approach to the Programme for International Student Assessment (PISA) taken in this special issue. PISA is here examined as a (knowledge for policy) regulatory instrument made by intertwined cognitive and social practices, and involving multidirectional flows of…
46 CFR 62.20-1 - Plans for approval.
Code of Federal Regulations, 2014 CFR
2014-10-01
... console, panel, and enclosure layouts. (3) Schematic or logic diagrams including functional relationships... programmable features. (6) A description of built-in test features and diagnostics. (7) Design Verification and...
Polarimetric Multispectral Imaging Technology
NASA Technical Reports Server (NTRS)
Cheng, L.-J.; Chao, T.-H.; Dowdy, M.; Mahoney, C.; Reyes, G.
1993-01-01
The Jet Propulsion Laboratory is developing a remote sensing technology on which a new generation of compact, lightweight, high-resolution, low-power, reliable, versatile, programmable scientific polarimetric multispectral imaging instruments can be built to meet the challenge of future planetary exploration missions. The instrument is based on the fast programmable acousto-optic tunable filter (AOTF) of tellurium dioxide (TeO2) that operates in the wavelength range of 0.4-5 microns. Basically, the AOTF multispectral imaging instrument measures incoming light intensity as a function of spatial coordinates, wavelength, and polarization. Its operation can be in either sequential, random access, or multiwavelength mode as required. This provides observation flexibility, allowing real-time alternation among desired observations, collecting needed data only, minimizing data transmission, and permitting implementation of new experiments. These will result in optimization of the mission performance with minimal resources. Recently we completed a polarimetric multispectral imaging prototype instrument and performed outdoor field experiments for evaluating application potentials of the technology. We also investigated potential improvements on AOTF performance to strengthen technology readiness for applications. This paper will give a status report on the technology and a prospect toward future planetary exploration.
Diagnostic Differentiation of Autism Spectrum Disorders and Pragmatic Language Impairment
ERIC Educational Resources Information Center
Reisinger, Lisa M.; Cornish, Kim M.; Fombonne, Eric
2011-01-01
The present study examined diagnostic differentiation between school-aged children with autism spectrum disorders (ASD) and children with pragmatic language impairment (PLI). Standardized diagnostic instruments were used to investigate the relationship between severity of "autism triad" impairments and group membership. The Autism Diagnostic…
NASA Astrophysics Data System (ADS)
Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.
2018-03-01
The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.
1991-07-01
transmitter, usually reliable over extended periods (i.e., several months). Vendors: Bindicator Inc. Endress and Hauser Instruments Port Huron, MI 48061...Inc. MicroSwitch Division Michigan City, IN 46360 Honeywell (219/872- . 11) Dayton, Ohio 45424 (513/237-4075) Endress & Hauser Instruments Greenwood...Honeywell (312/355-3055) Dayton, Ohio 45424 (513/237-4075) Endress & Hauser Instruments Greenwood, IN 46143 Omega Engineering Inc. (317/535-7138
Current issues in diagnostic breast pathology.
Walker, Rosemary A; Hanby, Andy; Pinder, Sarah E; Thomas, Jeremy; Ellis, Ian O
2012-09-01
On behalf of the NHS Breast Screening Programme Pathology Coordinating Group we present recommendations for terminology and diagnostic criteria for a number of key areas of practice in breast pathology where terminology can be confusing and where accurate communication will ensure appropriate clinical management. These recommendations cover columnar cell lesions and the spectrum of changes that can be seen in these epithelial proliferations, lobular neoplasia, micrometastases and isolated tumour cells in axillary lymph nodes, the use of basal/myoepithelial markers in diagnostic practice and oestrogen receptor testing in ductal carcinoma in situ.
Ustün, B; Compton, W; Mager, D; Babor, T; Baiyewu, O; Chatterji, S; Cottler, L; Göğüş, A; Mavreas, V; Peters, L; Pull, C; Saunders, J; Smeets, R; Stipec, M R; Vrasti, R; Hasin, D; Room, R; Van den Brink, W; Regier, D; Blaine, J; Grant, B F; Sartorius, N
1997-09-25
The WHO Study on the reliability and validity of the alcohol and drug use disorder instruments in an international study which has taken place in centres in ten countries, aiming to test the reliability and validity of three diagnostic instruments for alcohol and drug use disorders: the Composite International Diagnostic Interview (CIDI), the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) and a special version of the Alcohol Use Disorder and Associated Disabilities Interview schedule-alcohol/drug-revised (AUDADIS-ADR). The purpose of the reliability and validity (R&V) study is to further develop the alcohol and drug sections of these instruments so that a range of substance-related diagnoses can be made in a systematic, consistent, and reliable way. The study focuses on new criteria proposed in the tenth revision of the International Classification of Diseases (ICD-10) and the fourth revision of the diagnostic and statistical manual of mental disorders (DSM-IV) for dependence, harmful use and abuse categories for alcohol and psychoactive substance use disorders. A systematic study including a scientifically rigorous measure of reliability (i.e. 1 week test-retest reliability) and validity (i.e. comparison between clinical and non-clinical measures) has been undertaken. Results have yielded useful information on reliability and validity of these instruments at diagnosis, criteria and question level. Overall the diagnostic concordance coefficients (kappa, kappa) were very good for dependence disorders (0.7-0.9), but were somewhat lower for the abuse and harmful use categories. The comparisons among instruments and independent clinical evaluations and debriefing interviews gave important information about possible sources of unreliability, and provided useful clues on the applicability and consistency of nosological concepts across cultures.
LaBarre, Paul; Hawkins, Kenneth R.; Gerlach, Jay; Wilmoth, Jared; Beddoe, Andrew; Singleton, Jered; Boyle, David; Weigl, Bernhard
2011-01-01
Background Molecular assays targeted to nucleic acid (NA) markers are becoming increasingly important to medical diagnostics. However, these are typically confined to wealthy, developed countries; or, to the national reference laboratories of developing-world countries. There are many infectious diseases that are endemic in low-resource settings (LRS) where the lack of simple, instrument-free, NA diagnostic tests is a critical barrier to timely treatment. One of the primary barriers to the practicality and availability of NA assays in LRS has been the complexity and power requirements of polymerase chain reaction (PCR) instrumentation (another is sample preparation). Methodology/Principal Findings In this article, we investigate the hypothesis that an electricity-free heater based on exothermic chemical reactions and engineered phase change materials can successfully incubate isothermal NA amplification assays. We assess the heater's equivalence to commercially available PCR instruments through the characterization of the temperature profiles produced, and a minimal method comparison. Versions of the prototype for several different isothermal techniques are presented. Conclusions/Significance We demonstrate that an electricity-free heater based on exothermic chemical reactions and engineered phase change materials can successfully incubate isothermal NA amplification assays, and that the results of those assays are not significantly different from ones incubated in parallel in commercially available PCR instruments. These results clearly suggest the potential of the non-instrumented nucleic acid amplification (NINA) heater for molecular diagnostics in LRS. When combined with other innovations in development that eliminate power requirements for sample preparation, cold reagent storage, and readout, the NINA heater will comprise part of a kit that should enable electricity-free NA testing for many important analytes. PMID:21573065
DMD-based programmable wide field spectrograph for Earth observation
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Costes, Vincent; Hébert, Philippe-Jean
2015-03-01
In Earth Observation, Universe Observation and Planet Exploration, scientific return could be optimized in future missions using MOEMS devices. In Earth Observation, we propose an innovative reconfigurable instrument, a programmable wide-field spectrograph where both the FOV and the spectrum could be tailored thanks to a 2D micromirror array (MMA). For a linear 1D field of view (FOV), the principle is to use a MMA to select the wavelengths by acting on intensity. This component is placed in the focal plane of a first grating. On the MMA surface, the spatial dimension is along one side of the device and for each spatial point, its spectrum is displayed along the perpendicular direction: each spatial and spectral feature of the 1D FOV is then fully adjustable dynamically and/or programmable. A second stage with an identical grating recomposes the beam after wavelengths selection, leading to an output tailored 1D image. A mock-up has been designed, fabricated and tested. The micromirror array is the largest DMD in 2048 x 1080 mirrors format, with a pitch of 13.68μm. A synthetic linear FOV is generated and typical images have been recorded o at the output focal plane of the instrument. By tailoring the DMD, we could modify successfully each pixel of the input image: for example, it is possible to remove bright objects or, for each spatial pixel, modify the spectral signature. The very promising results obtained on the mock-up of the programmable wide-field spectrograph reveal the efficiency of this new instrument concept for Earth Observation.
Microfluidic diagnostics for low-resource settings
NASA Astrophysics Data System (ADS)
Hawkins, Kenneth R.; Weigl, Bernhard H.
2010-02-01
Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.
NASA Astrophysics Data System (ADS)
Romani, Aldo; Grazia, Chiara; Anselmi, Chiara; Miliani, Costanza; Brunetti, Brunetto Giovanni
2011-06-01
In this paper a new compact and portable instrument for combined reflectance, time-resolved and steady-state fluorescence is presented. All the optical parts of the apparatus, carefully described in the text, were chosen after an extensive market survey in order to obtain the best performances coupled with the smallest dimensions. This instrument through the use of a dedicated multiple fiber optic probe, allows the complete photophysical behaviors of investigated materials to be collected from the same point of the analyzed surface. In this way, the resultant instrumental setup is a portable device, usable in situ for non destructive and non invasive diagnostic purposes in the field of cultural heritage. Preliminary results concerning organic dyes characterization, which is the main application of luminescence-based diagnostic techniques in artworks, are presented and compared with those previously obtained using separate devices. Concerning reflectance data, improvements in the deep detectable UV spectral range have been achieved switching from the integrating sphere of the old instrument to bifurcated optical fibers used as probe in the new one. Special attention was devoted to test the instrument capability in order to obtain the true emission spectrum, corrected for the selfabsorption effect, for which good results were found. This particular experimental procedure is strongly recommended, by a diagnostic point of view, to avoid distortions in the instrumental responses, namely the spectral shape and emission maximum wavelength of a fluorophore as function of the color saturation.
NASA Astrophysics Data System (ADS)
Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Sachenko, V. D.; Gall, L. N.; Zarutskii, I. V.; Gall, N. R.
2013-05-01
A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings based on the carbon-13 isotope breath test has been designed and constructed. Important stages of the work included (i) calculating a low-aberration mass analyzer, (ii) manufacturing and testing special gas inlet system, and (iii) creating a small-size collector of ions. The proposed instrument ensures 13C/12C isotopic ratio measurement to within 1.7‰ (pro mille) accuracy, which corresponds to requirements for a diagnostic tool. Preliminary medical testing showed that the mass spectrometer is applicable to practical diagnostics. The instrument is also capable of measuring isotopic ratios of other light elements, including N, O, B (for BF2+ ions), Ar, Cl, and S.
Research and realization of signal simulation on virtual instrument
NASA Astrophysics Data System (ADS)
Zhao, Qi; He, Wenting; Guan, Xiumei
2010-02-01
In the engineering project, arbitrary waveform generator controlled by software interface is needed by simulation and test. This article discussed the program using the SCPI (Standard Commands For Programmable Instruments) protocol and the VISA (Virtual Instrument System Architecture) library to control the Agilent signal generator (Agilent N5182A) by instrument communication over the LAN interface. The program can conduct several signal generations such as CW (continuous wave), AM (amplitude modulation), FM (frequency modulation), ΦM (phase modulation), Sweep. As the result, the program system has good operability and portability.
Diagnostics of transparent polymer coatings of metal items
NASA Astrophysics Data System (ADS)
Varepo, L. G.; Ermakova, I. N.; Nagornova, I. V.; Kondratov, A. P.
2017-08-01
The methods of visual and instrumental express diagnostics of safety critical defects and non-uniform thickness of transparent mono- and multilayer polyolefin surface coating of metal items are analyzed in the paper. The instrumental diagnostics method relates to colorimetric measuring based on effects, which appear in the polarized light for extrusion polymer coatings. A color coordinates dependence (in the color system CIE La*b*) on both HDPE / PVC coating thickness fluctuation values (from average ones) and coating interlayer or adhesion layer delaminating is shown. A variation of color characteristics in the polarized light at a liquid penetration into delaminated polymer layers is found. Measuring parameters and critical uncertainties are defined.
Automation, consolidation, and integration in autoimmune diagnostics.
Tozzoli, Renato; D'Aurizio, Federica; Villalta, Danilo; Bizzaro, Nicola
2015-08-01
Over the past two decades, we have witnessed an extraordinary change in autoimmune diagnostics, characterized by the progressive evolution of analytical technologies, the availability of new tests, and the explosive growth of molecular biology and proteomics. Aside from these huge improvements, organizational changes have also occurred which brought about a more modern vision of the autoimmune laboratory. The introduction of automation (for harmonization of testing, reduction of human error, reduction of handling steps, increase of productivity, decrease of turnaround time, improvement of safety), consolidation (combining different analytical technologies or strategies on one instrument or on one group of connected instruments) and integration (linking analytical instruments or group of instruments with pre- and post-analytical devices) opened a new era in immunodiagnostics. In this article, we review the most important changes that have occurred in autoimmune diagnostics and present some models related to the introduction of automation in the autoimmunology laboratory, such as automated indirect immunofluorescence and changes in the two-step strategy for detection of autoantibodies; automated monoplex immunoassays and reduction of turnaround time; and automated multiplex immunoassays for autoantibody profiling.
Polarimetry of the HI Lyman-alpha for coronal magnetic field diagnostics
NASA Technical Reports Server (NTRS)
Fineschi, Silvano; Hoover, Richard B.; Zukic, Muamer; Kim, Jongmin; Walker, Arthur B. C., Jr.; Baker, Phillip, C.
1993-01-01
We discuss and analyze the possible sources of observational and instrumental uncertainty that can be encountered in measuring magnetic fields of the solar corona through polarimetric observations of the Hanle effect of the coronal Ly-alpha line. The Hanle effect is the modification of the linear polarization of a resonantly scattered line, due to the presence of a magnetic field. Simulated observations are used to examine how polarimetric measurements of this effect are affected by the line-of-sight integration, the electron collisions, and the Ly-alpha geocorona. We plan to implement the coronal magnetic field diagnostics via the Ly-alpha Hanle effect using an all-reflecting Ly-alpha coronagraph/polarimeter (Ly-alphaCoPo) which employs reflecting multilayer mirrors, polarizers, and filters. We discuss here the requirements for such an instrument, and analyze the sources of instrumental uncertainty for polarimetric observations of the coronal Ly-alpha Hanle effect. We conclude that the anticipated polarization signal from the corona and the expected performance of the Ly-alphaCoPo instrument are such that the Ly-alpha Hanle effect method for coronal field diagnostics is feasible.
Malaria rapid diagnostic tests in endemic settings.
Maltha, J; Gillet, P; Jacobs, J
2013-05-01
Malaria rapid diagnostic tests (RDTs) are instrument-free tests that provide results within 20 min and can be used by community health workers. RDTs detect antigens produced by the Plasmodium parasite such as Plasmodium falciparum histidine-rich protein-2 (PfHPR2) and Plasmodium lactate dehydrogenase (pLDH). The accuracy of RDTs for the diagnosis of uncomplicated P. falciparum infection is equal or superior to routine microscopy (but inferior to expert microscopy). Sensitivity for Plasmodium vivax is 75-100%; for Plasmodium ovale and Plasmodium malariae, diagnostic performance is poor. Design limitations of RDTs include poor sensitivity at low parasite densities, susceptibility to the prozone effect (PfHRP2-detecting RDTs), false-negative results due to PfHRP2 deficiency in the case of pfhrp2 gene deletions (PfHRP2-detecting RDTs), cross-reactions between Plasmodium antigens and detection antibodies, false-positive results by other infections and susceptibility to heat and humidity. End-user's errors relate to safety, procedure (delayed reading, incorrect sample and buffer volumes) and interpretation (not recognizing invalid test results, disregarding faint test lines). Withholding antimalarial treatment in the case of negative RDT results tends to be infrequent and tendencies towards over-prescription of antibiotics have been noted. Numerous shortcomings in RDT kits' labelling, instructions for use (correctness and readability) and contents have been observed. The World Health Organization and partners actively address quality assurance of RDTs by comparative testing of RDTs, inspections of manufacturing sites, lot testing and training tools but no formal external quality assessment programme of end-user performance exists. Elimination of malaria requires RDTs with lower detection limits, for which nucleic acid amplification tests are under development. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.
Ashraf, Sania; Kao, Angie; Hugo, Cecilia; Christophel, Eva M; Fatunmbi, Bayo; Luchavez, Jennifer; Lilley, Ken; Bell, David
2012-10-24
Malaria diagnosis has received renewed interest in recent years, associated with the increasing accessibility of accurate diagnosis through the introduction of rapid diagnostic tests and new World Health Organization guidelines recommending parasite-based diagnosis prior to anti-malarial therapy. However, light microscopy, established over 100 years ago and frequently considered the reference standard for clinical diagnosis, has been neglected in control programmes and in the malaria literature and evidence suggests field standards are commonly poor. Microscopy remains the most accessible method for parasite quantitation, for drug efficacy monitoring, and as a reference of assessing other diagnostic tools. This mismatch between quality and need highlights the importance of the establishment of reliable standards and procedures for assessing and assuring quality. This paper describes the development, function and impact of a multi-country microscopy external quality assurance network set up for this purpose in Asia. Surveys were used for key informants and past participants for feedback on the quality assurance programme. Competency scores for each country from 14 participating countries were compiled for analyses using paired sample t-tests. In-depth interviews were conducted with key informants including the programme facilitators and national level microscopists. External assessments and limited retraining through a formalized programme based on a reference slide bank has demonstrated an increase in standards of competence of senior microscopists over a relatively short period of time, at a potentially sustainable cost. The network involved in the programme now exceeds 14 countries in the Asia-Pacific, and the methods are extended to other regions. While the impact on national programmes varies, it has translated in some instances into a strengthening of national microscopy standards and offers a possibility both for supporting revival of national microcopy programmes, and for the development of globally recognized standards of competency needed both for patient management and field research.
2012-01-01
Background Malaria diagnosis has received renewed interest in recent years, associated with the increasing accessibility of accurate diagnosis through the introduction of rapid diagnostic tests and new World Health Organization guidelines recommending parasite-based diagnosis prior to anti-malarial therapy. However, light microscopy, established over 100 years ago and frequently considered the reference standard for clinical diagnosis, has been neglected in control programmes and in the malaria literature and evidence suggests field standards are commonly poor. Microscopy remains the most accessible method for parasite quantitation, for drug efficacy monitoring, and as a reference of assessing other diagnostic tools. This mismatch between quality and need highlights the importance of the establishment of reliable standards and procedures for assessing and assuring quality. This paper describes the development, function and impact of a multi-country microscopy external quality assurance network set up for this purpose in Asia. Methods Surveys were used for key informants and past participants for feedback on the quality assurance programme. Competency scores for each country from 14 participating countries were compiled for analyses using paired sample t-tests. In-depth interviews were conducted with key informants including the programme facilitators and national level microscopists. Results External assessments and limited retraining through a formalized programme based on a reference slide bank has demonstrated an increase in standards of competence of senior microscopists over a relatively short period of time, at a potentially sustainable cost. The network involved in the programme now exceeds 14 countries in the Asia-Pacific, and the methods are extended to other regions. Conclusions While the impact on national programmes varies, it has translated in some instances into a strengthening of national microscopy standards and offers a possibility both for supporting revival of national microcopy programmes, and for the development of globally recognized standards of competency needed both for patient management and field research. PMID:23095668
Newton, Amanda S; Soleimani, Amir; Kirkland, Scott W; Gokiert, Rebecca J
2017-05-01
Specialized instruments to screen and diagnose mental health problems in children and adolescents are not yet standard components of clinical assessments in emergency departments (EDs). We conducted a systematic review to investigate the psychometric properties, accuracy, and performance metrics of instruments used in the ED to identify pediatric mental health and substance use problems. We searched seven electronic databases and the gray literature for psychometric validation studies, diagnostic studies, and cohort studies that assessed any instrument to screen for or diagnose mental illness, emotional or behavioral problems, or substance use disorders. Studies had to include children and adolescents with mental health presentations or positive screens for substance use. Two reviewers independently screened studies for relevance and quality. Diagnostic study quality was assessed with the four QUADAS-2 domains. Psychometric study quality was assessed with published criteria for instrument reliability, validity, and usability. We present a descriptive analysis of the reported psychometric properties and diagnostic performance of instruments for each study. Of the 4,832 references screened, 14 met inclusion criteria. Included studies evaluate 18 instruments for identifying suicide risk (six studies), alcohol use disorders (six studies), mood disorders (one study), and ED decision making (need for assessment, admission; one study). Nine studies include a psychometric focus but quality varies, with no studies fully meeting criteria for reliability, validity, and usability. Seven studies examine diagnostic performance of an instrument, but no study has a low risk of bias for all QUADAS-2 domains. The HEADS-ED instrument has good inter-rater reliability (r = 0.785) for identifying general mental health problems and modest evidence for ruling in patients requiring hospital admission (positive likelihood ratio [LR+] = 6.30). Internal consistency (reliability) varies for instruments to screen for suicide risk (α = 0.46-0.97), and no instruments have both high sensitivity and high specificity. The Ask Suicide-Screening Questions (ASQ) is highly sensitive (98%) and has strong evidence for ruling out risk (negative likelihood ratio [LR-] = 0.04). Among screening instruments for alcohol use disorders, internal consistency is high for the consumption subscale of the Alcohol Use Disorders Identification Test (α = 0.83-0.88) and the Adolescent Drinking Index (α = 0.92). Both instruments also had sound internal validity. Diagnostically, a two-item instrument based on DSM-IV criteria is the most accurate in identifying patients with a disorder (area under the curve = 0.89) and has modest evidence for ruling in and out risk (LR+ = 8.80, LR- = 0.13). From available evidence, we recommend that ED clinicians use 1) the HEADS-ED to rule in ED admission among pediatric patients with visits for mental health care, 2) the ASQ to rule out suicide risk among pediatric patients with any visit type, and 3) the DSM-IV two-item instrument to rule in/rule out alcohol use disorders among pediatric patients currently using alcohol. These instruments require minimal to no training or time commitment. We also recommend that clinicians become familiar with each instrument's psychometric properties to understand the quality of the evidence base. In this review, however, we identify methodologic limitations in the evidence base. To develop a robust evidence base, additional research is necessary. © 2017 by the Society for Academic Emergency Medicine.
Advances in Miniaturized Instruments for Genomics
2014-01-01
In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices. PMID:25114919
The impact of Mexico's conditional cash transfer programme, Oportunidades, on birthweight.
Barber, Sarah L; Gertler, Paul J
2008-11-01
To evaluate the impact of Oportunidades, a large-scale, conditional cash transfer programme in Mexico, on birthweight. The programme provides cash transfers to low-income, rural households in Mexico, conditional on accepting nutritional supplements health education, and health care. The primary analyses used retrospective reports from 840 women in poor rural communities participating in an effectiveness study and randomly assigned to incorporation into the programme in 1998 or 1999 across seven Mexican states. Pregnant women in participating households received nutrition supplements and health care, and accepted cash transfers. Using multivariate and instrumental variable analyses, we estimated the impact of the programme on birthweight in grams and low birthweight (<2500 g), receipt of any pre-natal care, and number of pre-natal visits. Oportunidades beneficiary status was associated with 127.3 g higher birthweight among participating women and a 4.6 percentage point reduction in low birthweight. The Oportunidades conditional cash transfer programme improved birthweight outcomes. This finding is relevant to countries implementing conditional cash transfer programmes.
[Concerning the development of nursing diagnostics, what are the accompanying dynamics?].
Romeder, Florence
2009-12-01
To insure that they are carried out in medical establishments, nursing diagnostics have been taught in Nursing Training Institutes since 1992. This innovative practice, which is now included in new study programmes, is a logical step to increase the responsibility of the nursing profession. The acknowledgement of this new role for the nursing profession enables nurses to free themselves from the essentially curative model. However, this innovation, borrowed from the Anglo-Saxons, doesn't seem to be welcomed and fully taken up by all in the medical professions. The purpose of this thesis is to examine the use being made of this by the medical professions in order to provide new realistic nursing programmes. It also tries to look at teaching and tutoring practices to achieve a greater competency in nursing diagnostics. It attempts to highlight the diverging reactions of the nursing and teaching professionals having to deal with these changes. And finally, it seeks to identify a favourable environment which would lead to an even greater professionalisation of both individual and collective.
Heart failure management programmes in Europe.
Jaarsma, T; Strömberg, A; De Geest, S; Fridlund, B; Heikkila, J; Mårtensson, J; Moons, P; Scholte op Reimer, W; Smith, K; Stewart, S; Thompson, D R
2006-09-01
The ESC guidelines recommend that an organised system of specialist heart failure (HF) care should be established to improve outcomes of HF patients. The aim of this study was therefore to identify the number and the content of HF management programmes in Europe. A two-phase descriptive study was conducted: an initial screening to identify the existence of HF management programmes; and a survey to describe the content in countries where at least 30% of the hospitals had a programme. Of the 43 European countries approached, 26 (60%) estimated the percentage of HF management programmes. Seven countries reported that they had such programmes in more than 30% of their hospitals. Of the 673 hospitals responding to the questionnaire, 426 (63%) had a HF management programme. Half of the programmes (n = 205) were located in an outpatient clinic. In the UK a combination of hospital and home-based programmes was common (75%). The most programmes included physical examination, telephone consultation, patient education, drug titration and diagnostic testing. Most (89%) programmes involved nurses and physicians. Multi-disciplinary teams were active in 56% of the HF programmes. The most prominent differences between the 7 countries were the degree of collaboration with home care and GP's, the role in palliative care and the funding. Only a few European countries have a large number of organised programmes for HF care and follow up. To improve outcomes of HF patients throughout Europe more effort should be taken to increase the number of these programmes in all countries.
Project DIVIDE Instrument Development. Technical Report # 0810
ERIC Educational Resources Information Center
Ketterlin-Geller, Leanne; Jung, Eunju; Geller, Josh; Yovanoff, Paul
2008-01-01
In this technical report, we describe the development of cognitive diagnostic test items that form the basis of the diagnostic system for Project DIVIDE (Dynamic Instruction Via Individually Designed Environments). The construct underlying the diagnostic test is division of fractions. We include a description of the process we used to identify the…
ERIC Educational Resources Information Center
Luiselli, James K.; Campbell, Susan; Cannon, Barbara; DiPietro, Ellette; Ellis, James T.; Taras, Marie; Lifter, Karin
2001-01-01
Data from 30 national service centers found the number of assessment instruments endorsed increased as centers adopted a multidisciplinary approach to education and treatment, the largest proportion of instruments fell within intellectual, motor, and language/communication domains, and instruments were used most frequently for diagnostic and…
The Nature and Development of Middle School Mathematics Teachers' Knowledge
ERIC Educational Resources Information Center
Beswick, Kim; Callingham, Rosemary; Watson, Jane
2012-01-01
In this article, we report on the use of a teacher profiling instrument with 62 middle school teachers at the start of a 3-year professional learning programme. The instrument was designed to assess the aspects of teachers' knowledge identified by Shulman ("1987") refined by Ball et al. ("2008") and extended to include teachers' confidence to use…
ERIC Educational Resources Information Center
Kohoutek, Jan
2014-01-01
Utilising insights from policy instrument theory, the article analyses the design, functioning and effects of the tools used by the Czech Accreditation Commission (CAC) and the Slovak Accreditation Commission (SAC) in the 2000s. Aside from programme accreditation, the other tools analysed are: institutional approval, institutional evaluations,…
Hikichi, Hiroyuki; Kondo, Naoki; Kondo, Katsunori; Aida, Jun; Takeda, Tokunori; Kawachi, Ichiro
2015-09-01
The efficacy of promoting social interactions to improve the health of older adults is not fully established due to residual confounding and selection bias. The government of Taketoyo town, Aichi Prefecture, Japan, developed a resident-centred community intervention programme called 'community salons', providing opportunities for social interactions among local older residents. To evaluate the impact of the programme, we conducted questionnaire surveys for all older residents of Taketoyo. We carried out a baseline survey in July 2006 (prior to the introduction of the programme) and assessed the onset of functional disability during March 2012. We analysed the data of 2421 older people. In addition to the standard Cox proportional hazard regression, we conducted Cox regression with propensity score matching (PSM) and an instrumental variable (IV) analysis, using the number of community salons within a radius of 350 m from the participant's home as an instrument. In the 5 years after the first salon was launched, the salon participants showed a 6.3% lower incidence of functional disability compared with non-participants. Even adjusting for sex, age, equivalent income, educational attainment, higher level activities of daily living and depression, the Cox adjusted HR for becoming disabled was 0.49 (95% CI 0.33 to 0.72). Similar results were observed using PSM (HR 0.52, 95% CI 0.33 to 0.83) and IV-Cox analysis (HR 0.50, 95% CI 0.34 to 0.74). A community health promotion programme focused on increasing social interactions among older adults may be effective in preventing the onset of disability. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Advances in the diagnosis of bovine besnoitiosis: current options and applications for control.
Gutiérrez-Expósito, Daniel; Ferre, Ignacio; Ortega-Mora, Luis M; Álvarez-García, Gema
2017-10-01
Bovine besnoitiosis, which is caused by the tissue cyst-forming intracellular parasite Besnoitia besnoiti, is a chronic and debilitating disease that is responsible for severe economic losses in the cattle raised under extensive husbandry systems. The absence of vaccines, treatments or a health scheme at local, national and international levels has led to a rapid spread of bovine besnoitiosis from western Europe towards eastern countries and northwards. Moreover, this parasitic disease is widely present in many sub-Saharan countries. Thus, bovine besnoitiosis should be included in the animal health scheme of beef cattle herds. Accurate diagnostic tools and common diagnostic procedures are mandatory in any control programme. Relevant advances have been made in this field during the last decade. Succeeding with accurate diagnosis relies on the technique employed and the antibody and parasite kinetics of the infection stage, which may notably influence control programmes and surveillance. Moreover, control programmes should be adapted to the epidemiological status of the disease, as the disease presentation in a herd has important implications for prospective control. Herein, we review the clinical disease presentation of bovine besnoitiosis and the correlation between its clinical course and laboratory parameters. We also provide an update on the available diagnostic tools, discuss their strengths and pitfalls, and provide guidelines for their use in control, surveillance and epidemiological studies. A rational control strategy is also recommended. Copyright © 2017 Australian Society for Parasitology. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Boboc, A.; Gil, C.; Terranova, D.; Orsitto, F. P.; Soare, S.; Lotte, P.; Sozzi, C.; Imazawa, R.; Kubo, H.
2018-07-01
JT-60SA is the large Tokamak device that is being built in Japan under the Broader Approach Satellite Tokamak Programme and the Japanese National Programme and will operate as a satellite machine for ITER. The main goal of the JT-60SA Programme is to provide valuable information for the ITER steady-state scenario and for the design of DEMO, where the real-time control of the safety factor profile is very important, in connection with both MHD stability and plasma confinement. It has been demonstrated in this work that to this end polarimetry measurements are necessary, in particular in order to reconstruct the safety factor profile in reversed shear scenarios. In this paper we present the main steps of a conceptual feasibility study of a multi-channel polarimeter diagnostic and the resulting optimised geometry. In this study, magnetic scenario modelling, a realistic CAD-driven design and long-term operation requirements, rarely even considered at this stage, have been considered. It is shown that a far infrared polarimeter system, with a laser operating at a wavelength of 194.7 μm and up to twelve channels can be envisaged for JT-60SA. The top requirements can be attained, i.e., that the polarimeter, together with other diagnostic measurements, should provide q-profile reconstruction with an accuracy of 10% for the entire plasma cycle and suitable time resolution for real-time applications, in particular in high density and ITER-relevant plasma scenarios.
Greene, Greg; Sriruttan, Charlotte; Le, Thuy; Chiller, Tom; Govender, Nelesh P
2017-03-01
As HIV treatment programmes scale up to meet the UNAIDS 90-90-90 goals, care must be taken to start antiretroviral treatment safely in patients with advanced disease (CD4 counts <200 cells/μl) who are simultaneously at risk for opportunistic infections and immune reconstitution inflammatory syndrome. Invasive fungal diseases pose a great threat at this critical time point, though the development of inexpensive and highly accurate rapid diagnostic tests has changed the approach HIV programmes are taking to reduce the high mortality associated with these opportunistic infections. This article summarizes recent advances and findings in fungal opportunistic infection diagnostics with a focus on screening to prevent cryptococcal meningitis. Cryptococcal antigen (CrAg) screening using a lateral flow assay platform is cost-effective and feasible to implement as either a laboratory reflex or point-of-care test. Recent CrAg screening pilots have elucidated the varying prevalence of cryptococcal antigenemia across geographic regions, which may aid programme planning. Evidence from recently completed clinical trials provides a strong motivation for the use of CrAg titer to refine treatment options for patients with subclinical cryptococcal disease. Although several operational barriers to programme effectiveness still need to be addressed, the utility of CrAg screening using inexpensive and accurate antigen assays has been demonstrated in real-world HIV programmes, paving the way for development and testing of other fungal opportunistic infection screening strategies and for an integrated advanced HIV disease testing package to reduce AIDS mortality and ensure safe antiretroviral treatment initiation.
Evaluating disease management programme effectiveness: an introduction to instrumental variables.
Linden, Ariel; Adams, John L
2006-04-01
This paper introduces the concept of instrumental variables (IVs) as a means of providing an unbiased estimate of treatment effects in evaluating disease management (DM) programme effectiveness. Model development is described using zip codes as the IV. Three diabetes DM outcomes were evaluated: annual diabetes costs, emergency department (ED) visits and hospital days. Both ordinary least squares (OLS) and IV estimates showed a significant treatment effect for diabetes costs (P = 0.011) but neither model produced a significant treatment effect for ED visits. However, the IV estimate showed a significant treatment effect for hospital days (P = 0.006) whereas the OLS model did not. These results illustrate the utility of IV estimation when the OLS model is sensitive to the confounding effect of hidden bias.
Advanced life support control/monitor instrumentation concepts for flight application
NASA Technical Reports Server (NTRS)
Heppner, D. B.; Dahlhausen, M. J.; Fell, R. B.
1986-01-01
Development of regenerative Environmental Control/Life Support Systems requires instrumentation characteristics which evolve with successive development phases. As the development phase moves toward flight hardware, the system availability becomes an important design aspect which requires high reliability and maintainability. This program was directed toward instrumentation designs which incorporate features compatible with anticipated flight requirements. The first task consisted of the design, fabrication and test of a Performance Diagnostic Unit. In interfacing with a subsystem's instrumentation, the Performance Diagnostic Unit is capable of determining faulty operation and components within a subsystem, perform on-line diagnostics of what maintenance is needed and accept historical status on subsystem performance as such information is retained in the memory of a subsystem's computerized controller. The second focus was development and demonstration of analog signal conditioning concepts which reduce the weight, power, volume, cost and maintenance and improve the reliability of this key assembly of advanced life support instrumentation. The approach was to develop a generic set of signal conditioning elements or cards which can be configured to fit various subsystems. Four generic sensor signal conditioning cards were identified as being required to handle more than 90 percent of the sensors encountered in life support systems. Under company funding, these were detail designed, built and successfully tested.
Detailed Performance Assessment for the ITER ECE Diagnostic
NASA Astrophysics Data System (ADS)
Rowan, W.; Austin, M.; Houshmandyar, S.; Phillips, P.; Beno, J.; Bryant, A.; Ouroua, A.; Weeks, D.; Hubbard, A.; Taylor, G.
2017-10-01
One of the primary diagnostics for electron temperature (Te) measurement on ITER is based on the detection of electron cyclotron emission (ECE) Here we describe the predicted performance of the newly completed ECE diagnostic design by quantitatively following the emission from the plasma to the instruments and including the calibration method to assess accuracy. Operation of the diagnostic at 5.3 T is the main interest here but critical features of the emission spectra for 2.65 T and 1.8 T will be described. ECE will be collected by two very similar optical systems: one a radial view, the other an oblique view. Both measurements are used for Te while the oblique view also allows detection of non-thermal distortion in the electron distribution. An in-vacuum calibration source is included in the front end of each view to calibrate out the effect of any degradation of in-vessel optics. Following collection, the emission is split into orthogonal polarizations and transmitted to the detection instruments via waveguides filled with dry nitrogen, a choice that simplifies construction and analysis. Near the instruments, a switchyard is used to select which polarization and view is detected by each instrument. The design for the radiometer used for 5.3 T will be described in detail. Supported by PPPL/US-DA via subcontract S013464-H to UT Austin.
On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework
NASA Technical Reports Server (NTRS)
Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg
2007-01-01
Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).
A subscale facility for liquid rocket propulsion diagnostics at Stennis Space Center
NASA Technical Reports Server (NTRS)
Raines, N. G.; Bircher, F. E.; Chenevert, D. J.
1991-01-01
The Diagnostics Testbed Facility (DTF) at NASA's John C. Stennis Space Center in Mississippi was designed to provide a testbed for the development of rocket engine exhaust plume diagnostics instrumentation. A 1200-lb thrust liquid oxygen/gaseous hydrogen thruster is used as the plume source for experimentation and instrument development. Theoretical comparative studies have been performed with aerothermodynamic codes to ensure that the DTF thruster (DTFT) has been optimized to produce a plume with pressure and temperature conditions as much like the plume of the Space Shuttle Main Engine as possible. Operation of the DTFT is controlled by an icon-driven software program using a series of soft switches. Data acquisition is performed using the same software program. A number of plume diagnostics experiments have utilized the unique capabilities of the DTF.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
UV Spectrometer System AFGL 801 A HUP
1989-05-01
These criteria can be established when more is known about the launch vehicles . The spectrometer will be operated before, during and after each test to...between flights would also be cut dramatically. The Forth code would be written on an IBM PC and transferred to EEPROMs ( Electrically Erasab!- Programmable...Read Only Memory) in the flight instruments. The use of EEPROMs, which are electrically programmable and erasable, allows the whole process of
An Investigation of the Reacting and Non-Reacting Flow Characteristics of Solid Fuel Ramjets.
1980-09-01
which was run on the IBM-360 computer at the Naval 23 Postgraduate School. Programs for Texas Instruments TI - 59 programmable calculator were utilized...Pc’ F P A e 12 = g(y+l) F + PA e-TT 2(R F (9) lil Equations 7, 8, and 9 were solved for each run by software programs written for the TI - 59 programmable calculator . The
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual field laser instrument. 886.1360 Section 886.1360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument...
2013-08-15
OVERVIEW OF THE MATERIALS DIAGNOSTIC LABORATORY. THE NEAR END SHOWS THE SURFACE ANALYSIS INSTRUMENTS SUCH AS THE SECONDARY ION MASS SPECTROSCOPE (CLOSEST) AND THE TWO ELECTRON SPECTROSCOPY INSTRUMENTS, WHILE THE FAR END SHOWS THE NEW SCANNING ELECTRON MICROSCOPES
Roets-Merken, Lieve M; Zuidema, Sytse U; Vernooij-Dassen, Myrra J F J; Teerenstra, Steven; Hermsen, Pieter G J M; Kempen, Gertrudis I J M; Graff, Maud J L
2018-01-01
Objective To evaluate the effectiveness of a nurse-supported self-management programme to improve social participation of dual sensory impaired older adults in long-term care homes. Design Cluster randomised controlled trial. Setting Thirty long-term care homes across the Netherlands. Participants Long-term care homes were randomised into intervention clusters (n=17) and control clusters (n=13), involving 89 dual sensory impaired older adults and 56 licensed practical nurses. Intervention Nurse-supported self-management programme. Measurements Effectiveness was evaluated by the primary outcome social participation using a participation scale adapted for visually impaired older adults distinguishing four domains: instrumental activities of daily living, social-cultural activities, high-physical-demand and low-physical-demand leisure activities. A questionnaire assessing hearing-related participation problems was added as supportive outcome. Secondary outcomes were autonomy, control, mood and quality of life and nurses’ job satisfaction. For effectiveness analyses, linear mixed models were used. Sampling and intervention quality were analysed using descriptive statistics. Results Self-management did not affect all four domains of social participation; however. the domain ‘instrumental activities of daily living’ had a significant effect in favour of the intervention group (P=0.04; 95% CI 0.12 to 8.5). Sampling and intervention quality was adequate. Conclusions A nurse-supported self-management programme was effective in empowering the dual sensory impaired older adults to address the domain ‘instrumental activities of daily living’, but no differences were found in addressing the other three participation domains. Self-management showed to be beneficial for managing practical problems, but not for those problems requiring behavioural adaptations of other persons. Trial registration number NCT01217502; Results. PMID:29371264
Hopkins during SODI-DCMIX 2 Experiment
2013-11-30
ISS038-E-009255 (26 Nov. 2013) --- In the International Space Station?s Destiny laboratory, NASA astronaut Michael Hopkins, Expedition 38 flight engineer, prepares to install and activate the Selectable Optics Diagnostic Instrument (SODI) cell array two in the Microgravity Science Glovebox (MSG) for the Selectable Optics Diagnostic Instrument-Diffusion Coefficient in Mixtures 2 (SODI-DCMIX 2) experiment. SODI-DCMIX 2 is supporting research to determine diffusion coefficients in different petroleum field samples and refine petroleum reservoir models to help lead to more efficient extraction of oil resources.
Hopkins during SODI-DCMIX 2 Experiment
2013-11-30
ISS038-E-009253 (26 Nov. 2013) --- In the International Space Station’s Destiny laboratory, NASA astronaut Michael Hopkins, Expedition 38 flight engineer, prepares to install and activate the Selectable Optics Diagnostic Instrument (SODI) cell array two in the Microgravity Science Glovebox (MSG) for the Selectable Optics Diagnostic Instrument-Diffusion Coefficient in Mixtures 2 (SODI-DCMIX 2) experiment. SODI-DCMIX 2 is supporting research to determine diffusion coefficients in different petroleum field samples and refine petroleum reservoir models to help lead to more efficient extraction of oil resources.
M.H.D. Diagnostics - Gas Temperature and Emittance
1960-04-06
AD-A280 700 DTIC $ELECTE M.H.D. DIAGNOSTICS - GAS TEMPERATURE AND EMITTANCE by W. E. HILL REPORT NO. 60GL63 APRIL 6, 1960t i T i n n e iii, ic ie. n ...Accesion For NTIS CRA&I DTIC TAB Una;Olow;ced Justification Distribution y Availability C,.. Avail ard C.A Dist Special GENERAL* ELECTRIC _ l I SCHOWCTADY...from the Instrumen- tation viewpoint. Some of the instrumentation techniques developed $ n the allied field of combustion instrumentation can be expected
An Efficient Reachability Analysis Algorithm
NASA Technical Reports Server (NTRS)
Vatan, Farrokh; Fijany, Amir
2008-01-01
A document discusses a new algorithm for generating higher-order dependencies for diagnostic and sensor placement analysis when a system is described with a causal modeling framework. This innovation will be used in diagnostic and sensor optimization and analysis tools. Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in-situ platforms. This algorithm will serve as a power tool for technologies that satisfy a key requirement of autonomous spacecraft, including science instruments and in-situ missions.
[Diagnostic of ADHD in childhood and adolescence with the K-SADS-PL].
Schmidt, Sören; Banaschewski, Tobias; Garbe, Edeltraut; Petermann, Franz; Petermann, Ulrike
2013-01-01
Attention Deficit-/Hyperactivity Disorder (ADHD) is one of the most prevalent psychiatric disorders in childhood and adolescence, often accompanied by comorbid disorders. A high standard of diagnostic assessment combined with a demand for valid diagnostic instruments is necessary. The K-SADS-PL is an established semi-structured interview, focusing on the categorical assessment of psychiatric disorders. The aim of the following study was to examine specific characteristics of ADHD symptomatology including functional and behavioral assessment. Therefore correlations between the result in a diagnostic interview (K-SADS-PL) and different ADHD-specific instruments were performed. Groups were formed (exposed vs. unexposed), based on the diagnostic finding in the K-SADS-PL. Group-specific test score differences were calculated and compared by multivariate analyses of covariance. Children with ADHD showed a significantly higher impact of conduct and emotional problems than the unexposed group. Health related quality of life was more impaired in children and families suffering from ADHD which refers to the relevance of family-oriented psychotherapy.
Shirazian, Shayan; Aina, Olufemi; Park, Youngjun; Chowdhury, Nawsheen; Leger, Kathleen; Hou, Linle; Miyawaki, Nobuyuki; Mathur, Vandana S
2017-01-01
Chronic kidney disease-associated pruritus (CKD-aP) is a distressing, often overlooked condition in patients with CKD and end-stage renal disease. It affects ~40% of patients with end-stage renal disease and has been associated with poor quality of life, poor sleep, depression, and mortality. Prevalence estimates vary based on the instruments used to diagnose CKD-aP, and standardized diagnostic instruments are sorely needed. Treatment studies have often yielded conflicting results. This is likely related to studies that are limited by small sample size, flawed designs, and nonstandardized diagnostic instruments. Several large well-designed treatment trials have recently been completed and may soon influence CKD-aP management. PMID:28176969
ERIC Educational Resources Information Center
Halawa, Ahmed; Sharma, Ajay; Bridson, Julie M.; Lyon, Sarah; Prescott, Denise; Guha, Arpan; Taylor, David
2017-01-01
Background: Good performance in a summative assessment does not always equate to educational gain following a course. An educational programme may focus on improving student's performance on a particular test instrument. For example, practicing multiple choice questions may lead to mastery of the instrument itself rather than testing the knowledge…
Controlling CAMAC instrumentation through the USB port
NASA Astrophysics Data System (ADS)
Ribas, R. V.
2012-02-01
A programmable device to interface CAMAC instrumentation to the USB port of computers, without the need of heavy, noisy and expensive CAMAC crates is described in this article. Up to four single-width modules can be used. Also, all software necessary for a multi-parametric data acquisition system was developed. A standard crate-controller based on the same project is being designed.
ERIC Educational Resources Information Center
Krupp-Schleußner, Valerie; Lehmann-Wermser, Andreas
2018-01-01
Does extended music education during primary school foster long-term musical participation? What other factors contribute to long-term musical participation? In our study on "Impacts and Long-Term Effects of Musical Participation," we investigate how the German programme "An Instrument for Every Child (JeKi)," which fosters the…
Development and Validation of the International Baccalaureate Learner Profile Questionnaire (IBLPQ)
ERIC Educational Resources Information Center
Walker, Allan; Lee, Moosung; Bryant, Darren A.
2016-01-01
The Learner Profile (LP) frames International Baccalaureate (IB) learning outcomes across the three programme levels and, as such, plays a key role in measuring the success of the rapidly growing number of IB schools in the Asia-Pacific Region. Our aim was to develop an instrument to measure the IBLP and validate the instrument through a series of…
[Diagnostics of work motivation (DIAMO): optimization and construct validity].
Ranft, Andreas; Fiedler, Rolf; Greitemann, Bernhard; Heuft, Gereon
2009-01-01
Faced with increasing cost pressure of the social insurance system the carriers of rehabilitation programs focus on the efficacy of their measures. The diagnostic instrument for work motivation (DIAMO) has been developed to assess the influence of job-related motivation on the rehabilitation outcome. The inner structure of the instrument was validated and optimized in a cohort of medical rehabilitation patients (n = 422). Construct validity was further tested by using established instruments. Ten scales related to self-image, intention of action and goodness of fit show good psychometric qualities (Cronbachs alpha: 0.72 - 0.86). The constructs correlate moderately-to-strongly with personality-oriented scales while correlation with disease-related contents is low. The DIAMO is a generic and not disease oriented instrument. It would be expected to facilitate the development of vocational interventions to increase the rehabilitation outcome.
NASA Astrophysics Data System (ADS)
Krisdiana, A.; Aminah, N. S.; Nurosyid, F.
2018-03-01
This study aims to investigate the scientific literacy among 12th grade science students in SMA Negeri 2 Karanganyar. The instrument used is a four-tier wave diagnostic instrument. This instrument was originally used to diagnose students’ conceptions about nature and propagation of waves. This study using quantitative descriptive method. The diagnostic results based on dominant students’ answers show the lack of knowledge percentage of 14.3%-77.1%, alternative conceptions percentage 0%-60%, scientific conceptions percentage 0%-65.7%. Lack of knowledge indicated when there is doubt about at least one tier of the student’s answer. The results of the research shows that the students’ dominant scientific literacy is in the nominal literacy category with the percentage of 22.9% - 91.4%, the functional literacy with the percentage 2.86% - 28.6%, and the conceptual/procedural literacy category with the percentage 0% - 65.7%. Description level of nominal literacy in context of the current study is student have alternative conceptions and lack of knowledge. Student recognize the scientific terms, but is not capable to justify this term.
Braun, Tobias; Grüneberg, Christian; Thiel, Christian
2018-04-01
Routine screening for frailty could be used to timely identify older people with increased vulnerability und corresponding medical needs. The aim of this study was the translation and cross-cultural adaptation of the PRISMA-7 questionnaire, the FRAIL scale and the Groningen Frailty Indicator (GFI) into the German language as well as a preliminary analysis of the diagnostic test accuracy of these instruments used to screen for frailty. A diagnostic cross-sectional study was performed. The instrument translation into German followed a standardized process. Prefinal versions were clinically tested on older adults who gave structured in-depth feedback on the scales in order to compile a final revision of the German language scale versions. For the analysis of diagnostic test accuracy (criterion validity), PRISMA-7, FRAIL scale and GFI were considered the index tests. Two reference tests were applied to assess frailty, either based on Fried's model of a Physical Frailty Phenotype or on the model of deficit accumulation, expressed in a Frailty Index. Prefinal versions of the German translations of each instrument were produced and completed by 52 older participants (mean age: 73 ± 6 years). Some minor issues concerning comprehensibility and semantics of the scales were identified and resolved. Using the Physical Frailty Phenotype (frailty prevalence: 4%) criteria as a reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence: 23%) as the reference standard, the accuracy was good (AUC between 0.73 and 0.88). German language versions of PRISMA-7, FRAIL scale and GFI have been established and preliminary results indicate sufficient diagnostic test accuracy that needs to be further established.
Diagnostics aid for mass spectrometer trouble-shooting
NASA Astrophysics Data System (ADS)
Filby, E. E.; Rankin, R. A.; Webb, G. W.
The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho Chemical Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis provides the user with a set of possible solutions to the observed problems, graded as to their probabilities. Besides the trouble-shooting benefits expected from this system, it will also provide structures diagnostic training for lab personnel. In addition, development of the system knowledge base has already produced a better understanding of instrument behavior. Two key findings are that a good user interface is necessary for full acceptance of the tool, and a development system should include standard programming capabilities as well as the expert system shell.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-14
... ADVIA Centaur Anti- January 20, 2012. Diagnostics Inc. HBs2 Assay and Quality Control Material. P100005... Flowonix Medical, Prometra February 7, 2012. Inc. (approved under Programmable Medasys, Inc.). Infusion...
Ali, Amir Monir
2018-01-01
The aim of the study was to evaluate the commercially available orthopedic metal artifact reduction (OMAR) technique in postoperative three-dimensional computed tomography (3DCT) reconstruction studies after spinal instrumentation and to investigate its clinical application. One hundred and twenty (120) patients with spinal metallic implants were included in the study. All had 3DCT reconstruction examinations using the OMAR software after obtaining the informed consents and approval of the Institution Ethical Committee. The degree of the artifacts, the related muscular density, the clearness of intermuscular fat planes, and definition of the adjacent vertebrae were qualitatively evaluated. The diagnostic satisfaction and quality of the 3D reconstruction images were thoroughly assessed. The majority (96.7%) of 3DCT reconstruction images performed were considered satisfactory to excellent for diagnosis. Only 3.3% of the reconstructed images had rendered unacceptable diagnostic quality. OMAR can effectively reduce metallic artifacts in patients with spinal instrumentation with highly diagnostic 3DCT reconstruction images.
ExoMars Raman laser spectrometer overview
NASA Astrophysics Data System (ADS)
Rull, F.; Sansano, A.; Díaz, E.; Canora, C. P.; Moral, A. G.; Tato, C.; Colombo, M.; Belenguer, T.; Fernández, M.; Manfredi, J. A. R.; Canchal, R.; Dávila, B.; Jiménez, A.; Gallego, P.; Ibarmia, S.; Prieto, J. A. R.; Santiago, A.; Pla, J.; Ramos, G.; González, C.
2010-09-01
The Raman Laser Spectrometer (RLS) is one of the Pasteur Payload instruments, within the ESA's Aurora Exploration Programme, ExoMars mission. The RLS Instrument will perform Raman spectroscopy on crushed powered samples deposited on a small container after crushing the cores obtained by the Rover's drill system. This is the first time that a Raman spectrometer will be launched in an out planetary mission. The Instrument will be accommodated and operate inside the Rover's ALD (Analytical Laboratory Drawer), complying with COSPAR (Committee on Space Research) Planetary Protection requirements. The RLS Instrument is composed by the following units: SPU (Spectrometer Unit); iOH: (Internal Optical Head); ICEU (Instrument Control and Excitation Unit). Other instrument units are EH (Electrical Harness), OH (Optical Harness) and RLS SW On-Board.
Innovative financing instruments for global health 2002-15: a systematic analysis.
Atun, Rifat; Silva, Sachin; Knaul, Felicia M
2017-07-01
Development assistance for health (DAH), the value of which peaked in 2013 and fell in 2015, is unlikely to rise substantially in the near future, increasing reliance on domestic and innovative financing sources to sustain health programmes in low-income and middle-income countries. We examined innovative financing instruments (IFIs)-financing schemes that generate and mobilise funds-to estimate the quantum of financing mobilised from 2002 to 2015. We identified ten IFIs, which mobilised US$8·9 billion (2·3% of overall DAH) in 2002-15. The funds generated by IFIs were channelled mostly through GAVI and the Global Fund, and used for programmes for new and underused vaccines, HIV/AIDS, malaria, tuberculosis, and maternal and child health. Vaccination programmes received the largest amount of funding ($2·6 billion), followed by HIV/AIDS ($1080·7 million) and malaria ($1028·9 million), with no discernible funding targeted to non-communicable diseases. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.
German Higher Education in the Framework of the Bologna Process
NASA Astrophysics Data System (ADS)
Richter, Roland
In 1997/98, the 16 German Länder tentatively agreed on the establishment of a new degree structure for German higher education in the form of Bachelors and Masters programmes. Moreover, the German government passed federal legislation that officially adopted accreditation as a new steering instrument to approve these newly established Bachelors and Masters programmes. Thus, since 1998 almost all universities, Fachhochschulen (FH), faculties, and especially the engineering departments have been busy designing new Bachelors and Masters degree programmes. On the other hand, accreditation of programmes as a means of quality assurance has become the new pre-requisite for state recognition, which is operated by an overarching national Accreditation Board that on it turn recognises agencies that accredit particular degree programmes. All these changes will be a challenge and are likely to change the overall structure of the traditional German higher education system severely.
[Horizon 2020, new EU Framework programme for research and innovation, 2014-2020].
Kinkorová, Judita
2014-01-01
Horizon 2020 is a financial instrument implementing the Innovation Union, a Europe 2020 flagship initiative aimed at securing Europes global competitiveness. Running from 2014 to 2020 with a budget of just over € 80 billion, the EUs new programme for research and innovation is part of the drive to create new growth and jobs in Europe. Societal challenge Health, demographic change and wellbeing is an important part of Horizon 2020.
Development of a Measurement Instrument to Assess Students' Electrolyte Conceptual Understanding
ERIC Educational Resources Information Center
Lu, Shanshan; Bi, Hualin
2016-01-01
To assess students' conceptual understanding levels and diagnose alternative frameworks of the electrolyte concept, a measurement instrument was developed using the Rasch model. This paper reports the use of the measurement instrument to assess 559 students from grade 10 to grade 12 in two cities. The results provided both diagnostic and summative…
ERIC Educational Resources Information Center
Bastiaansen, Jojanneke A.; Meffert, Harma; Hein, Simone; Huizinga, Petra; Ketelaars, Cees; Pijnenborg, Marieke; Bartels, Arnold; Minderaa, Ruud; Keysers, Christian; de Bildt, Annelies
2011-01-01
Autism Diagnostic Observation Schedule (ADOS) module 4 was investigated in an independent sample of high-functioning adult males with an autism spectrum disorder (ASD) compared to three specific diagnostic groups: schizophrenia, psychopathy, and typical development. ADOS module 4 proves to be a reliable instrument with good predictive value. It…
Conquest, Jennifer; Jacobi, Michael; Skinner, John; Tennant, Marc
2015-02-01
The aim of this study was to trial the methodology and administration processes of a public paediatric capitation programme provided in the period 1 July 2011 to 31 December 2011 through a Bachelor of Oral Health programme in rural New South Wales (NSW), Australia, where access to public dental services is limited. The principal structure of the programme was the development of three diagnostic pathways: active caries and pain (Pathway A); active caries and no pain (Pathway B); and no active caries and no pain (Pathway C). In 2011, de-identified treatment data for NSW public dental services' patients under 18 years of age were analysed to identify the top 10 dental treatment items. These items were clustered according to the mean decayed and/or filled surface of patients under 18 years of age who had decayed, filled or missing teeth. Each treatment item was allocated 60% of the 2011 Australian Government Department of Veteran Affairs Schedule of Fees. The programme was trialled in Charles Sturt University dental facility in Wagga Wagga, NSW. The programme targeted patients in the following age groups: 0-5 years; 6-11 years; and 12-17 years. The 6-month trial provided 361 patients with a capitation pathway, at a total cost of $47,567.90, averaging $131.76 per capitation pathway. The total number of items provided (n=2,070) equated to an average of 5.7 items per capitation diagnostic pathway. This model offered an early entry point for paediatric patients to access dental care that addressed their needs, whilst being flexible enough to be fiscally attractive. © 2014 FDI World Dental Federation.
The MetOp second generation 3MI instrument
NASA Astrophysics Data System (ADS)
Manolis, Ilias; Grabarnik, Semen; Caron, Jérôme; Bézy, Jean-Loup; Loiselet, Marc; Betto, Maurizio; Barré, Hubert; Mason, Graeme; Meynart, Roland
2013-10-01
The MetOp-SG programme is a joint Programme of EUMETSAT and ESA. ESA develops the prototype MetOp-SG satellites (including associated instruments) and procures, on behalf of EUMETSAT, the recurrent satellites (and associated instruments). Two parallel, competitive phase A/B1 studies for MetOp Second Generation (MetOp-SG) have been concluded in May 2013. The implementation phases (B2/C/D/E) are planned to start the first quarter of 2014. ESA is responsible for instrument design of six missions, namely Microwave Sounding Mission (MWS), Scatterometer mission (SCA), Radio Occultation mission (RO), Microwave Imaging mission (MWI), Ice Cloud Imager (ICI) and Multi-viewing, Multi-channel, Multi-polarisation imaging mission (3MI). The paper will present the main performances of the 3MI instrument and will highlight the performance improvements with respect to its heritage derived by the POLDER instrument, such as number of spectral channels and spectral range coverage, swath and ground spatial resolution. The engineering of some key performance requirements (multi-viewing, polarisation sensitivity, straylight etc.) will also be discussed. The results of the feasibility studies will be presented together with the programmatics for the instrument development. Several pre-development activities have been initiated to retire highest risks and to demonstrate the ultimate performances of the 3MI optics. The scope, objectives and current status of those activities will be presented. Key technologies involved in the 3MI instrument design and implementation are considered to be: the optical design featuring aspheric optics, the implementation of broadband Anti Reflection coatings featuring low polarisation and low de-phasing properties, the development and qualification of polarisers with acceptable performances as well as spectral filters with good uniformities over a large clear aperture.
Buddle, B M; de Lisle, G W; Griffin, J F T; Hutchings, S A
2015-06-01
The control of tuberculosis (TB) in cattle and farmed deer in New Zealand has been greatly influenced by the existence of a wildlife reservoir of Mycobacterium bovis infection, principally the Australian brushtail possum (Trichosurus vulpecula). The reduction in possum numbers in areas with endemic M. bovis infection through vigorous vector control operations has been a major contributor to the marked reduction in the number of infected cattle and farmed deer herds in the past two decades. Management of TB in cattle and farmed deer in New Zealand has involved a combination of vector control, regionalisation of diagnostic testing of cattle and deer herds, abattoir surveillance and movement control from vector risk areas. Accurate diagnosis of infected cattle and deer has been a crucial component in the control programme. As the control programme has evolved, test requirements have changed and new tests have been introduced or test interpretations modified. Subspecific strain typing of M. bovis isolates has proved to be a valuable component in the epidemiological investigation of herd breakdowns to identify whether the source of infection was domestic livestock or wildlife. New initiatives will include the use of improved models for analysing diagnostic test data and characterising disease outbreaks leading to faster elimination of infection from herds. The introduction of the National Animal Identification Tracing programme will allow better risk profiling of individual herds and more reliable tracing of animal movements. TB in cattle and farmed deer in New Zealand can only be controlled by eliminating the disease in both domestic livestock and the wildlife reservoir.
Instrument to synchronize Thomson scattering diagnostic measurements with MHD acitivity in a tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wintenberg, A.L.
1985-04-01
An instrument to synchronize the firing of a ruby laser for a Thomson scattering diagnostic with plasma oscillations was designed, developed, and evaluated. The instrument will fire the laser at a user-selected phase of an input sine or sawtooth wave with an accuracy of +-15/sup 0/. Allowable frequencies range from 20 to 500 Hz for a sawtooth and from 1 to 30 kHz for a sine wave. The instrument also allows synchronization with a sine wave to be enabled by a preselected sawtooth phase. The instrument uses analog signal processing circuits to separate the signal components, remove unwanted components, andmore » produce zero-phase synchronization pulses. The instrument measures the period between zero-phase pulses in order to produce phase synchronization pulses delayed a fraction of the period from the zero-phase pulses. The laser is fired by the phase synchronization pulse. Unwanted signal components are attenuated by bandpass filters. A digitally controlled self-adjusting bandpass filter for sine processing. The instrument was used to investigate the variation of the electron temperature profile with the phase of the x-ray signal from an Impurity Studies Experiment (ISX-B) plasma exhibiting magnetohydrodynamic (MHD) activity.« less
Pierce, Mark C; Weigum, Shannon E; Jaslove, Jacob M; Richards-Kortum, Rebecca; Tkaczyk, Tomasz S
2014-01-01
One of the key elements in point-of-care (POC) diagnostic test instrumentation is the optical system required for signal detection and/or imaging. Many tests which use fluorescence, absorbance, or colorimetric optical signals are under development for management of infectious diseases in resource limited settings, where the overall size and cost of the device is of critical importance. At present, high-performance lenses are expensive to fabricate and difficult to obtain commercially, presenting barriers for developers of in vitro POC tests or microscopic image-based diagnostics. We recently described a compact "hybrid" objective lens incorporating both glass and plastic optical elements, with a numerical aperture of 1.0 and field-of-view of 250 μm. This design concept may potentially enable mass-production of high-performance, low-cost optical systems which can be easily incorporated in the readout path of existing and emerging POC diagnostic assays. In this paper, we evaluate the biological imaging performance of these lens systems in three broad POC diagnostic application areas; (1) bright field microscopy of histopathology slides, (2) cytologic examination of blood smears, and (3) immunofluorescence imaging. We also break down the fabrication costs and draw comparisons with other miniature optical systems. The hybrid lenses provided images with quality comparable to conventional microscopy, enabling examination of neoplastic pathology and infectious parasites including malaria and cryptosporidium. We describe how these components can be produced at below $10 per unit in full-scale production quantities, making these systems well suited for use within POC diagnostic instrumentation.
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays
NASA Astrophysics Data System (ADS)
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-01
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications. Electronic supplementary information (ESI) available: Experimental procedures and analytical data are provided. See DOI: 10.1039/c5nr00697j
Computer-based diagnosis of illness in historical persons.
Peters, T J
2013-01-01
Retrospective diagnosis of illness in historical figures is a popular but somewhat unreliable pastime due to the lack of detailed information and reliable reports about clinical features and disease progression. Modern computer-based diagnostic programmes have been used to supplement historical documents and accounts, offering new and more objective approaches to the retrospective investigations of the medical conditions of historical persons. In the case of King George III, modern technology has been used to strengthen the findings of previous reports rejecting the popular diagnosis of variegate porphyria in the King, his grandson Augustus d'Esté and his antecedent King James VI and I. Alternative diagnoses based on these programmes are indicated. The Operational Criteria in Studies of Psychotic Illness (OPCRIT) programme and the Young mania scale have been applied to the features described for George III and suggest a diagnosis of bipolar disorder. The neuro-diagnostic programme SimulConsult was applied to Augustus d'Esté and suggests a diagnosis of neuromyelitis optica rather than acute porphyria with secondarily multiple sclerosis, as proposed by others. James VI and I's complex medical history and the clinical features of his behavioural traits were also subjected to SimulConsult analysis; acute porphyria was rejected and the unexpected diagnosis of attenuated (mild) Lesch-Nyhan disease offered. A brief review of these approaches along with full reference listings to the methodology including validation are provided. Textual analysis of the written and verbal outputs of historical figures indicate possible future developments in the diagnosis of medical disorders in historical figures.
ERIC Educational Resources Information Center
Luyster, Rhiannon; Gotham, Katherine; Guthrie, Whitney; Coffing, Mia; Petrak, Rachel; Pierce, Karen; Bishop, Somer; Esler, Amy; Hus, Vanessa; Oti, Rosalind; Richler, Jennifer; Risi, Susan; Lord, Catherine
2009-01-01
The Autism Diagnostic Observation Schedule (ADOS; Lord et al., J Autism Dev Disord, 30(3):205-223, 2000) is widely accepted as a "gold standard" diagnostic instrument, but it is of restricted utility with very young children. The purpose of the current project was to modify the ADOS for use in children under 30 months of age. A modified ADOS, the…
Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P
2014-01-01
The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.
ERIC Educational Resources Information Center
Trullen, Jordi; Rodriguez, Sebastian
2013-01-01
While the stated aim of quality assessments is to improve the quality of the products and services offered by universities, some faculty view them as instrumental in justifying government budget cuts in education. By means of a survey administered to more than 300 faculty from 20 academic programmes undergoing quality assessments, we studied…
ERIC Educational Resources Information Center
Segeritz, Micha; Pant, Hans Anand
2013-01-01
This article summarizes the key finding of a study that (a) tests the measurement invariance (MI) of the popular Students' Approaches to Learning instrument (Programme for International Student Assessment [PISA]) across ethnic/cultural groups within a country and (b) discusses implications for research focusing on the role of affective measures in…
NASA Astrophysics Data System (ADS)
Freudling, M.; Egner, S.; Hering, M.; Carbó, F. L.; Thiele, H.
2017-09-01
The Meteosat Third Generation (MTG) Programme will ensure the future continuity and enhancement of meteorological data from geostationary orbit as currently provided by the Meteosat Second Generation (MSG) system. The industrial prime contractor for the space segment is Thales Alenia Space (France), with a core team consortium including OHB System AG (Germany).
[Acquired brain injury: a proposal for its definition, diagnostic criteria and classification].
Castellanos-Pinedo, Fernando; Cid-Gala, Manuel; Duque, Pablo; Ramirez-Moreno, José M; Zurdo-Hernández, José M
2012-03-16
Acquired brain injury is a heterogeneous clinical concept that goes beyond the limits of the classical medical view, which tends to define processes and diseases on the grounds of a single causation. Although in the medical literature it appears fundamentally associated to traumatic brain injury, there are many other causes and management is similar in all of them, during the post-acute and chronic phases, as regards the measures to be taken concerning rehabilitation and attention to dependence. Yet, despite being an important health issue, today we do not have a set of diagnostic criteria or a classification for this condition. This is a serious handicap when it comes to carrying out epidemiological studies, designing specific care programmes and comparing results among different programmes and centres. Accordingly, the Extremadura Acquired Brain Injury Health Care Plan working group has drawn up these proposed diagnostic criteria, definition and classification. The proposal is intended to be essentially practical, its main purpose being to allow correct identification of the cases that must be attended to and to optimise the use of neurorehabilitation and attention to dependence resources, thereby ensuring attention is provided on a fair basis.
Rodríguez-Escudero, Juan Pablo; López-Jiménez, Francisco; Trejo-Gutiérrez, Jorge F
2011-01-01
This article reviews different characteristics of validity in a clinical diagnostic test. In particular, we emphasize the likelihood ratio as an instrument that facilitates the use of epidemiologic concepts in clinical diagnosis.
2015-01-05
monitor the radiation environment in a geosynchronous satellite. 15. SUBJECT TERMS Radiation testing, Cobalt, Microcontroller 16. SECURITY...electronics including: an Aeroflex 8051 microcontroller , a Maxwell Electrically Erasable Programmable Read-Only Memory (EEPROM), Texas Instrument analog
Yang, J; McCrae, R R; Costa, P T; Yao, S; Dai, X; Cai, T; Gao, B
2000-01-01
We examined the reliability, cross-instrument validity, and factor structure of Chinese adaptations of the Personality Diagnostic Questionnaire (PDQ-4+; N = 1,926) and Personality Disorders Interview (PDI-IV; N = 525) in psychiatric patients. Comparisons with data from Western countries suggest that the psychometric properties of these two instruments are comparable across cultures. Low to modest agreement between the PDQ-4+ and PDI-IV was observed for both dimensional and categorical personality disorder evaluations. When the PDI-IV was used as the diagnostic standard, the PDQ-4+ showed higher sensitivity than specificity, and higher negative predictive power than positive predictive power. Factor analyses of both instruments replicated the four-factor structure O'Connor and Dyce (1998) found in Western samples. Results suggested that conceptions and measures of DSM-IV personality disorders are cross-culturally generalizable to Chinese psychiatric populations.
2013-01-01
Background We set out to examine whether structured professional judgement instruments DUNDRUM-3 programme completion (D-3) and DUNDRUM-4 recovery (D-4) scales along with measures of risk, mental state and global function could distinguish between those forensic patients detained in a secure forensic hospital (not guilty by reason of insanity or unfit to stand trial) who were subsequently discharged by a mental health review board. We also examined the interaction between these measures and risk, need for therapeutic security and eventual conditional discharge. Methods A naturalistic observational cohort study was carried out for 56 patients newly eligible for conditional discharge. Patients were rated using the D-3, D-4 and other scales including HCR-20, S-RAMM, START, SAPROF, PANSS and GAF and then observed over a period of twenty three months during which they were considered for conditional discharge by an independent Mental Health Review Board. Results The D-3 distinguished which patients were subsequently discharged by the Mental Health Review board (AUC = 0.902, p < 0.001) as did the D-4 (AUC = 0.848, p < 0.001). Item to outcome analysis showed each item of the D-3 and D-4 scales performed significantly better than random. The HCR-20 also distinguished those later discharged (AUC = 0.838, p < 0.001) as did the S-RAMM, START, SAPROF, PANSS and GAF. The D-3 and D-4 scores remained significantly lower (better) for those discharged even when corrected for the HCR-20 total score. Item to outcome analyses and logistic regression analysis showed that the strongest antecedents of discharge were the GAF and the DUNDRUM-3 programme completion scores. Conclusions Structured professional judgement instruments should improve the quality, consistency and transparency of clinical recommendations and decision making at mental health review boards. Further research is required to determine whether the DUNDRUM-3 programme completion and DUNDRUM-4 recovery instruments predict those who are or are not recalled or re-offend after conditional discharge. PMID:23837697
La création et l’implantation réussie d’un outil de remédiation en résidence de médecine familiale
Sanche, Gilbert; Béland, Normand; Audétat, Marie-Claude
2011-01-01
Résumé Problème à l’étude Comme dans la majorité des programmes de formation médicale post-graduée, environ 10% des résidents du programme de résidence en médecine familiale de l’Université de Montréal éprouvent des difficultés considérables dans la construction de leurs compétences. Objectif du programme Afin de mieux soutenir les enseignants du programme dans le diagnostic de ces difficultés ainsi que dans la conception, la planification et le suivi d’une stratégie de remédiation, le Comité d’évaluation du programme de résidence a conçu un outil constitué d’un plan type de remédiation et d’un guide de rédaction de ce plan. Description du programme L’outil de remédiation est constitué de 2 documents. Le premier est un plan type de remédiation constitué d’une partie contractuelle suivie de 4 sections: diagnostic pédagogique, intentions de remédiation, moyens de remédiation et évaluation de la remédiation, avec un bilan intermédiaire et un bilan final. Le deuxième est un guide de rédaction et de systématisation d’un plan de remédiation. Conclusion L’accueil favorable qu’a reçu l’outil et l’utilisation qui en a été faite durant l’année de son implantation témoignent du succès des processus que nous avions adoptés. L’appui de la faculté, le mécanisme de «co-construction» de l’outil, de même que la formation et le soutien aux utilisateurs sont des facteurs qui expliquent ce succès. Un projet de recherche est en route pour documenter l’impact qu’aura l’utilisation de cet outil dans notre programme de résidence. PMID:22170208
Community engagement: outcomes for occupational therapy students, faculty and clients.
Schindler, Victoria P
2014-06-01
Students in health care professions, including occupational therapy, are required to develop knowledge, skills and attitudes in mental health and research. Persons diagnosed with a mental illness, a learning disability or an autism-spectrum disorder desire to achieve goals in higher education and employment. Faculty in health care programmes strives to meet professional goals and accreditation and institution requirements for teaching, service and scholarship. The Bridge Program, a programme based on principles of community engagement, was developed to meet the needs of these three stakeholders. The objective of this paper is to provide programme description and outcomes of the effectiveness of the Bridge Program for all three stakeholders. This uses mixed methods research design including descriptive and quantitative and qualitative one-group pre-test-post-test designs. Instruments consisted of the Occupational Therapy Student and Mental Health Population Scale and the Canadian Occupational Performance Measure. Quantitative results support that graduate occupational therapy students gained research and clinical skills (n = 100; p = .000); clients increased performance and satisfaction toward goals (n = 113; p = .000) and faculty (n = 1) achieved goals related to teaching, service and scholarship. Programmes based on principles of community engagement can address the needs of the community, can provide outcomes that advance knowledge about community practice and can result in benefits for all stakeholders. This paper is limited to generalization and instrumentation and recommends an ongoing evaluation of other community engagement programmes involving all stakeholders in the future research. Copyright © 2014 John Wiley & Sons, Ltd.
Next Generation P-Band Planetary Synthetic Aperture Radar
NASA Technical Reports Server (NTRS)
Rincon, Rafael; Carter, Lynn; Lu, Dee Pong Daniel
2016-01-01
The Space Exploration Synthetic Aperture Radar (SESAR) is an advanced P-band beamforming radar instrument concept to enable a new class of observations suitable to meet Decadal Survey science goals for planetary exploration. The radar operates at full polarimetry and fine (meter scale) resolution, and achieves beam agility through programmable waveform generation and digital beamforming. The radar architecture employs a novel low power, lightweight design approach to meet stringent planetary instrument requirements. This instrument concept has the potential to provide unprecedented surface and near- subsurface measurements applicable to multiple DecadalSurvey Science Goals.
Next Generation P-Band Planetary Synthetic Aperture Radar
NASA Technical Reports Server (NTRS)
Rincon, Rafael; Carter, Lynn; Lu, Dee Pong Daniel
2017-01-01
The Space Exploration Synthetic Aperture Radar (SESAR) is an advanced P-band beamforming radar instrument concept to enable a new class of observations suitable to meet Decadal Survey science goals for planetary exploration. The radar operates at full polarimetry and fine (meter scale) resolution, and achieves beam agility through programmable waveform generation and digital beamforming. The radar architecture employs a novel low power, lightweight design approach to meet stringent planetary instrument requirements. This instrument concept has the potential to provide unprecedented surface and near- subsurface measurements applicable to multiple Decadal Survey Science Goals.
Chandramohan, Daniel; Clark, Samuel J.; Jakob, Robert; Leitao, Jordana; Rao, Chalapati; Riley, Ian; Setel, Philip W.
2018-01-01
Background Verbal autopsy (VA) is a practical method for determining probable causes of death at the population level in places where systems for medical certification of cause of death are weak. VA methods suitable for use in routine settings, such as civil registration and vital statistics (CRVS) systems, have developed rapidly in the last decade. These developments have been part of a growing global momentum to strengthen CRVS systems in low-income countries. With this momentum have come pressure for continued research and development of VA methods and the need for a single standard VA instrument on which multiple automated diagnostic methods can be developed. Methods and findings In 2016, partners harmonized a WHO VA standard instrument that fully incorporates the indicators necessary to run currently available automated diagnostic algorithms. The WHO 2016 VA instrument, together with validated approaches to analyzing VA data, offers countries solutions to improving information about patterns of cause-specific mortality. This VA instrument offers the opportunity to harmonize the automated diagnostic algorithms in the future. Conclusions Despite all improvements in design and technology, VA is only recommended where medical certification of cause of death is not possible. The method can nevertheless provide sufficient information to guide public health priorities in communities in which physician certification of deaths is largely unavailable. The WHO 2016 VA instrument, together with validated approaches to analyzing VA data, offers countries solutions to improving information about patterns of cause-specific mortality. PMID:29320495
The Photovoltaic Array Space Power plus Diagnostics (PASP Plus) Flight Experiment
NASA Technical Reports Server (NTRS)
Piszczor, Michael F.; Curtis, Henry B.; Guidice, Donald A.; Severance, Paul S.
1992-01-01
An overview of the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) flight experiment is presented in outline and graphic form. The goal of the experiment is to test a variety of photovoltaic cell and array technologies under various space environmental conditions. Experiment objectives, flight hardware, experiment control and diagnostic instrumentation, and illuminated thermal vacuum testing are addressed.
ERIC Educational Resources Information Center
Wiggins, Lisa D.; Reynolds, Ann; Rice, Catherine E.; Moody, Eric J.; Bernal, Pilar; Blaskey, Lisa; Rosenberg, Steven A.; Lee, Li-Ching; Levy, Susan E.
2015-01-01
The Study to Explore Early Development (SEED) is a multi-site case-control study designed to explore the relationship between autism spectrum disorder (ASD) phenotypes and etiologies. The goals of this paper are to (1) describe the SEED algorithm that uses the Autism Diagnostic Interview-Revised (ADI-R) and Autism Diagnostic Observation Schedule…
Diagnostics in Japan's microgravity experiments
NASA Technical Reports Server (NTRS)
Kadota, Toshikazu
1995-01-01
The achievement of the combustion research under microgravity depends substantially on the availability of diagnostic systems. The non-intrusive diagnostic systems are potentially applicable for providing the accurate, realistic and detailed information on momentum, mass and energy transport, complex gas phase chemistry, and phase change in the combustion field under microgravity. The non-intrusive nature of optical instruments is essential to the measurement of combustion process under microgravity which is very nervous to any perturbation. However, the implementation of the non-intrusive combustion diagnostic systems under microgravity is accompanied by several constraints. Usually, a very limited space is only available for constructing a highly sophisticated system which is so sensitive that it is easily affected by the magnitude of the gravitational force, vibration and heterogeneous field of temperature and density of the environments. The system should be properly adjusted prior to the experiment. Generally, it is quite difficult to tune the instruments during measurements. The programmed sequence of operation should also be provided. Extensive effort has been toward the development of non-intrusive diagnostic systems available for the combustion experiments under microgravity. This paper aims to describe the current art and the future strategy on the non-intrusive diagnostic systems potentially applicable to the combustion experiments under microgravity in Japan.
Pinned, optically aligned diagnostic dock for use on the Z facility.
Gomez, M R; Rochau, G A; Bailey, J E; Dunham, G S; Kernaghan, M D; Gard, P; Robertson, G K; Owen, A C; Argo, J W; Nielsen, D S; Lake, P W
2012-10-01
The pinned optically aligned diagnostic dock (PODD) is a multi-configuration diagnostic platform designed to measure x-ray emission on the Z facility. The PODD houses two plasma emission acquisition (PEA) systems, which are aligned with a set of precision machined pins. The PEA systems are modular, allowing a single diagnostic housing to support several different diagnostics. The PEA configurations fielded to date include both time-resolved and time-integrated, 1D spatially resolving, elliptical crystal spectrometers, and time-integrated, 1D spatially resolving, convex crystal spectrometers. Additional proposed configurations include time-resolved, monochromatic mirrored pinhole imagers and arrays of filtered x-ray diodes, diamond photo-conducting diode detectors, and bolometers. The versatility of the PODD system will allow the diagnostic configuration of the Z facility to be changed without significantly adding to the turn-around time of the machine. Additionally, the PODD has been designed to allow instrument setup to be completed entirely off-line, leaving only a refined alignment process to be performed just prior to a shot, which is a significant improvement over the instrument the PODD replaces. Example data collected with the PODD are presented.
Xu, Jin; Xu, Zhao-Xia; Lu, Ping; Guo, Rui; Yan, Hai-Xia; Xu, Wen-Jie; Wang, Yi-Qin; Xia, Chun-Ming
2016-11-01
To develop an effective Chinese Medicine (CM) diagnostic model of coronary heart disease (CHD) and to confifirm the scientifific validity of CM theoretical basis from an algorithmic viewpoint. Four types of objective diagnostic data were collected from 835 CHD patients by using a self-developed CM inquiry scale for the diagnosis of heart problems, a tongue diagnosis instrument, a ZBOX-I pulse digital collection instrument, and the sound of an attending acquisition system. These diagnostic data was analyzed and a CM diagnostic model was established using a multi-label learning algorithm (REAL). REAL was employed to establish a Xin (Heart) qi defificiency, Xin yang defificiency, Xin yin defificiency, blood stasis, and phlegm fifive-card CM diagnostic model, which had recognition rates of 80.32%, 89.77%, 84.93%, 85.37%, and 69.90%, respectively. The multi-label learning method established using four diagnostic models based on mutual information feature selection yielded good recognition results. The characteristic model parameters were selected by maximizing the mutual information for each card type. The four diagnostic methods used to obtain information in CM, i.e., observation, auscultation and olfaction, inquiry, and pulse diagnosis, can be characterized by these parameters, which is consistent with CM theory.
The Adult Asperger Assessment (AAA): A Diagnostic Method
ERIC Educational Resources Information Center
Baron-Cohen, Simon; Wheelwright, Sally; Robinson, Janine; Woodbury-Smith, Marc
2005-01-01
At the present time there are a large number of adults who have "suspected" Asperger syndrome (AS). In this paper we describe a new instrument, the Adult Asperger Assessment (AAA), developed in our clinic for adults with AS. The need for a new instrument relevant to the diagnosis of AS in adulthood arises because existing instruments are designed…
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E; Baron-Cohen, Simon; Brayne, Carol
2015-11-01
Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not known nor how many such children would meet these criteria. The aim of this study was to evaluate children with a known diagnosis of autism in mainland China using the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview-Revised to verify that children who were given a diagnosis of autism made by Chinese clinicians in China were mostly children with severe autism. Of 50 children with an existing diagnosis of autism made by Chinese clinicians, 47 children met the diagnosis of autism on the Autism Diagnostic Observation Schedule algorithm and 44 children met the diagnosis of autism on the Autism Diagnostic Interview-Revised algorithm. Using the Gwet's alternative chance-corrected statistic, the agreement between the Chinese diagnosis and the Autism Diagnostic Observation Schedule diagnosis was very good (AC1 = 0.94, p < 0.005, 95% confidence interval (0.86, 1.00)), so was the agreement between the Chinese diagnosis and the Autism Diagnostic Interview-Revised (AC1 = 0.91, p < 0.005, 95% confidence interval (0.81, 1.00)). The agreement between the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview-Revised was lower but still very good (AC1 = 0.83, p < 0.005). © The Author(s) 2015.
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E; Baron-Cohen, Simon; Brayne, Carol
2016-01-01
Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not known nor how many such children would meet these criteria. The aim of this study was to evaluate children with a known diagnosis of autism in mainland China using the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview–Revised to verify that children who were given a diagnosis of autism made by Chinese clinicians in China were mostly children with severe autism. Of 50 children with an existing diagnosis of autism made by Chinese clinicians, 47 children met the diagnosis of autism on the Autism Diagnostic Observation Schedule algorithm and 44 children met the diagnosis of autism on the Autism Diagnostic Interview–Revised algorithm. Using the Gwet’s alternative chance-corrected statistic, the agreement between the Chinese diagnosis and the Autism Diagnostic Observation Schedule diagnosis was very good (AC1 = 0.94, p < 0.005, 95% confidence interval (0.86, 1.00)), so was the agreement between the Chinese diagnosis and the Autism Diagnostic Interview–Revised (AC1 = 0.91, p < 0.005, 95% confidence interval (0.81, 1.00)). The agreement between the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview–Revised was lower but still very good (AC1 = 0.83, p < 0.005). PMID:25757721
[Methodological problems in the use of information technologies in physical education].
Martirosov, E G; Zaĭtseva, G A
2000-01-01
The paper considers methodological problems in the use of computer technologies in physical education by applying diagnostic and consulting systems, educational and educational-and-training process automation systems, and control and self-control programmes for athletes and others.
Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma
2015-12-01
This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it was compared. One hundred twenty monolingual and bilingual children with and without LI participated (30 per group). A mixed-design analysis of variance was used to investigate the effects of LI and bilingualism on the NWRTs. Receiver operating characteristic analyses were conducted to evaluate the instruments' diagnostic value. Large negative effects of LI were found on both NWRTs, whereas negative effects of bilingualism only occurred on the language-specific NWRT. Both instruments had high clinical accuracy in the monolingual group, but only the Q-U NWRT had high clinical accuracy in the bilingual group. This study indicates that the Q-U NWRT is a promising diagnostic tool to help identify LI in bilingual children learning Dutch as a 2nd language. The instrument was clinically accurate in both a monolingual and bilingual group of children and seems better able to disentangle LI from language disadvantage than more language-specific measures.
TFTR diagnostic vacuum controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olsen, D.; Persons, R.
1981-01-01
The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.
Point-of-care technologies for molecular diagnostics using a drop of blood.
Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong
2014-03-01
Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Corlett, G. K.; Barton, I. J.; Donlon, C. J.; Edwards, M. C.; Good, S. A.; Horrocks, L. A.; Llewellyn-Jones, D. T.; Merchant, C. J.; Minnett, P. J.; Nightingale, T. J.; Noyes, E. J.; O'Carroll, A. G.; Remedios, J. J.; Robinson, I. S.; Saunders, R. W.; Watts, J. G.
The Advanced Along-Track Scanning Radiometer (AATSR) was launched on Envisat in March 2002. The AATSR instrument is designed to retrieve precise and accurate global sea surface temperature (SST) that, combined with the large data set collected from its predecessors, ATSR and ATSR-2, will provide a long term record of SST data that is greater than 15 years. This record can be used for independent monitoring and detection of climate change. The AATSR validation programme has successfully completed its initial phase. The programme involves validation of the AATSR derived SST values using in situ radiometers, in situ buoys and global SST fields from other data sets. The results of the initial programme presented here will demonstrate that the AATSR instrument is currently close to meeting its scientific objectives of determining global SST to an accuracy of 0.3 K (one sigma). For night time data, the analysis gives a warm bias of between +0.04 K (0.28 K) for buoys to +0.06 K (0.20 K) for radiometers, with slightly higher errors observed for day time data, showing warm biases of between +0.02 (0.39 K) for buoys to +0.11 K (0.33 K) for radiometers. They show that the ATSR series of instruments continues to be the world leader in delivering accurate space-based observations of SST, which is a key climate parameter.
Building and testing of MIDAS instrument sub-assemblies
NASA Astrophysics Data System (ADS)
Lewis, S. D.
2001-09-01
The MIDAS instrument is an atomic force microscope developed by ESTEC to fly on Rosetta. The purpose of the instrument is to sample and characterise cometary dust, which impinges upon a facetted wheel contained within the instrument enclosure. Due to its relative complexity, the long cruise phase of the Rosetta mission and the relatively novel use of piezomotors for all drive requirements the instrument has a number of interesting mechanisms engineering challenges. This paper describes the lubricant selection, EM and FM subassembly build and test campaigns carried out by AEA Technology Space in close support of the instrumentlevel activities which ran in parallel at ESTEC. The paper also identifies some lessons learned, which can be generally applied in other mechanism programmes.
NASA Astrophysics Data System (ADS)
Stuffler, Timo; Förster, Klaus; Hofer, Stefan; Leipold, Manfred; Sang, Bernhard; Kaufmann, Hermann; Penné, Boris; Mueller, Andreas; Chlebek, Christian
2009-10-01
In the upcoming generation of satellite sensors, hyperspectral instruments will play a significant role. This payload type is considered world-wide within different future planning. Our team has now successfully finalized the Phase B study for the advanced hyperspectral mission EnMAP (Environmental Mapping and Analysis Programme), Germans next optical satellite being scheduled for launch in 2012. GFZ in Potsdam has the scientific lead on EnMAP, Kayser-Threde in Munich is the industrial prime. The EnMAP instrument provides over 240 continuous spectral bands in the wavelength range between 420 and 2450 nm with a ground resolution of 30 m×30 m. Thus, the broad science and application community can draw from an extensive and highly resolved pool of information supporting the modeling and optimization process on their results. The performance of the hyperspectral instrument allows for a detailed monitoring, characterization and parameter extraction of rock/soil targets, vegetation, and inland and coastal waters on a global scale supporting a wide variety of applications in agriculture, forestry, water management and geology. The operation of an airborne system (ARES) as an element in the HGF hyperspectral network and the ongoing evolution concerning data handling and extraction procedures, will support the later inclusion process of EnMAP into the growing scientist and user communities.
Rapid diagnostic tests for malaria
Daily, Jennifer; Hotte, Nora; Dolkart, Caitlin; Cunningham, Jane; Yadav, Prashant
2015-01-01
Abstract Maintaining quality, competitiveness and innovation in global health technology is a constant challenge for manufacturers, while affordability, access and equity are challenges for governments and international agencies. In this paper we discuss these issues with reference to rapid diagnostic tests for malaria. Strategies to control and eliminate malaria depend on early and accurate diagnosis. Rapid diagnostic tests for malaria require little training and equipment and can be performed by non-specialists in remote settings. Use of these tests has expanded significantly over the last few years, following recommendations to test all suspected malaria cases before treatment and the implementation of an evaluation programme to assess the performance of the malaria rapid diagnostic tests. Despite these gains, challenges exist that, if not addressed, could jeopardize the progress made to date. We discuss recent developments in rapid diagnostic tests for malaria, highlight some of the challenges and provide suggestions to address them. PMID:26668438
Coleman, Susanne; Smith, Isabelle L; McGinnis, Elizabeth; Keen, Justin; Muir, Delia; Wilson, Lyn; Stubbs, Nikki; Dealey, Carol; Brown, Sarah; Nelson, E Andrea; Nixon, Jane
2018-02-01
To test the psychometric properties and clinical usability of a new Pressure Ulcer Risk Assessment Instrument including inter-rater and test-retest reliability, convergent validity and data completeness. Methodological and practical limitations associated with traditional Pressure Ulcer Risk Assessment Instruments, prompted a programme to work to develop a new instrument, as part of the National Institute for Health Research funded, Pressure UlceR Programme Of reSEarch (RP-PG-0407-10056). Observational field test. For this clinical evaluation 230 patients were purposefully sampled across four broad levels of pressure ulcer risk with representation from four secondary care and four community NHS Trusts in England. Blinded and simultaneous paired (ward/community nurse and expert nurse) PURPOSE-T assessments were undertaken. Follow-up retest was undertaken by the expert nurse. Field notes of PURPOSE-T use were collected. Data were collected October 2012-January 2013. The clinical evaluation demonstrated "very good" (kappa) inter-rater and test-retest agreement for PURPOSE-T assessment decision overall. The percentage agreement for "problem/no problem" was over 75% for the main risk factors. Convergent validity demonstrated moderate to high associations with other measures of similar constructs. The PURPOSE-T evaluation facilitated the initial validation and clinical usability of the instrument and demonstrated that PURPOSE-T is suitable of use in clinical practice. Further study is needed to evaluate the impact of using the instrument on care processes and outcomes. © 2017 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Youngstrom, Eric A.; Findling, Robert L.; Calabrese, Joseph R.; Gracious, Barbara L.; Demeter, Christine; DelPorto Bedoya, Denise; Price, Megan
2004-01-01
Objective: To compare the diagnostic efficiency of six index tests as predictors of juvenile bipolar disorder in two large outpatient samples, aged 5 to 10 and 11 to 17 years, gathered from 1997 to 2002. Method: DSM-IV diagnosis was based on a semistructured diagnostic interview (Schedule for Affective Disorders and Schizophrenia for School-Age…
ERIC Educational Resources Information Center
Magana, Sandy; Smith, Leann E.
2013-01-01
Research shows that Latinos are less likely to be diagnosed with autism than their non-Latino counterparts. One factor that may contribute to these differences is that autism diagnostic instruments have not been adapted for the Latino population. The present study compared scores from the Autism Diagnostic Interview-Revised for two groups: 48…
NASA Technical Reports Server (NTRS)
Conrad, A. R.; Lupton, W. F.
1992-01-01
Each Keck instrument presents a consistent software view to the user interface programmer. The view consists of a small library of functions, which are identical for all instruments, and a large set of keywords, that vary from instrument to instrument. All knowledge of the underlying task structure is hidden from the application programmer by the keyword layer. Image capture software uses the same function library to collect data for the image header. Because the image capture software and the instrument control software are built on top of the same keyword layer, a given observation can be 'replayed' by extracting keyword-value pairs from the image header and passing them back to the control system. The keyword layer features non-blocking as well as blocking I/O. A non-blocking keyword write operation (such as setting a filter position) specifies a callback to be invoked when the operation is complete. A non-blocking keyword read operation specifies a callback to be invoked whenever the keyword changes state. The keyword-callback style meshes well with the widget-callback style commonly used in X window programs. The first keyword library was built for the two Keck optical instruments. More recently, keyword libraries have been developed for the infrared instruments and for telescope control. Although the underlying mechanisms used for inter-process communication by each of these systems vary widely (Lick MUSIC, Sun RPC, and direct socket I/O, respectively), a basic user interface has been written that can be used with any of these systems. Since the keyword libraries are bound to user interface programs dynamically at run time, only a single set of user interface executables is needed. For example, the same program, 'xshow', can be used to display continuously the telescope's position, the time left in an instrument's exposure, or both values simultaneously. Less generic tools that operate on specific keywords, for example an X display that controls optical instrument exposures, have also been written using the keyword layer.
Barkema, H W; Orsel, K; Nielsen, S S; Koets, A P; Rutten, V P M G; Bannantine, J P; Keefe, G P; Kelton, D F; Wells, S J; Whittington, R J; Mackintosh, C G; Manning, E J; Weber, M F; Heuer, C; Forde, T L; Ritter, C; Roche, S; Corbett, C S; Wolf, R; Griebel, P J; Kastelic, J P; De Buck, J
2018-05-01
In the last decades, many regional and country-wide control programmes for Johne's disease (JD) were developed due to associated economic losses, or because of a possible association with Crohn's disease. These control programmes were often not successful, partly because management protocols were not followed, including the introduction of infected replacement cattle, because tests to identify infected animals were unreliable, and uptake by farmers was not high enough because of a perceived low return on investment. In the absence of a cure or effective commercial vaccines, control of JD is currently primarily based on herd management strategies to avoid infection of cattle and restrict within-farm and farm-to-farm transmission. Although JD control programmes have been implemented in most developed countries, lessons learned from JD prevention and control programmes are underreported. Also, JD control programmes are typically evaluated in a limited number of herds and the duration of the study is less than 5 year, making it difficult to adequately assess the efficacy of control programmes. In this manuscript, we identify the most important gaps in knowledge hampering JD prevention and control programmes, including vaccination and diagnostics. Secondly, we discuss directions that research should take to address those knowledge gaps. © 2017 Blackwell Verlag GmbH.
Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.
Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei
2012-06-01
The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.
Multispectral optical tweezers for molecular diagnostics of single biological cells
NASA Astrophysics Data System (ADS)
Butler, Corey; Fardad, Shima; Sincore, Alex; Vangheluwe, Marie; Baudelet, Matthieu; Richardson, Martin
2012-03-01
Optical trapping of single biological cells has become an established technique for controlling and studying fundamental behavior of single cells with their environment without having "many-body" interference. The development of such an instrument for optical diagnostics (including Raman and fluorescence for molecular diagnostics) via laser spectroscopy with either the "trapping" beam or secondary beams is still in progress. This paper shows the development of modular multi-spectral imaging optical tweezers combining Raman and Fluorescence diagnostics of biological cells.
Programmable Low-Voltage Circuit Breaker and Tester
NASA Technical Reports Server (NTRS)
Greenfield, Terry
2008-01-01
An instrumentation system that would comprise a remotely controllable and programmable low-voltage circuit breaker plus several electric-circuit-testing subsystems has been conceived, originally for use aboard a spacecraft during all phases of operation from pre-launch testing through launch, ascent, orbit, descent, and landing. The system could also be adapted to similar use aboard aircraft. In comparison with remotely controllable circuit breakers heretofore commercially available, this system would be smaller, less massive, and capable of performing more functions, as needed for aerospace applications.
Interactive Courseware Standards
1992-07-01
music industry standard provides data formats and transmission specifications for musical notation. Joint Photographic Experts Group (JPEG). This...has been used in the music industry for several years, especially for electronically programmable keyboards and 16 instruments. The video compression
The efficacy of education programme for preventing constipation in women.
Ayaz, Sultan; Hisar, Filiz
2014-06-01
This study was performed to evaluate the efficiency of the education programme for prevention of constipation in women. This study was performed as a pre-test-posttest design. Thirty-five women were included who have constipation problem. Data were collected by questionnaire: Constipation Severity Instrument (CSI), Constipation Visual Analogue Scale (CVAS) and Bristol Stool Chart (BSC). Eight home visits were made for each of the women and they were followed up for 3 months. Participants received an individual education programme that included advice on dietary consumption such as pulpy-fibrous nutrient consumption, fluid intake, an exercise regime and counselling about optimal position to defecate. The subscales of 'Colonic Inertia' and 'Pain', and CSI total mean scores and CVAS mean scores were decreased significantly after education programme (P < 0.05). According to the BSC, 71.5% of the women stated their stool form to be 'sausage-shaped, but lumpy' before the education programme, but after the said programme the percentage had dropped to 17.1%. Education programme given to women who had constipation were determined to have been effective in alleviating constipation. Nurses should develop appropriate and effective strategies to help women prevent constipation. © 2013 Wiley Publishing Asia Pty Ltd.
Application of tissue mesodissection to molecular cancer diagnostics.
Krizman, David; Adey, Nils; Parry, Robert
2015-02-01
To demonstrate clinical application of a mesodissection platform that was developed to combine advantages of laser-based instrumentation with the speed/ease of manual dissection for automated dissection of tissue off standard glass slides. Genomic analysis for KRAS gene mutation was performed on formalin fixed paraffin embedded (FFPE) cancer patient tissue that was dissected using the mesodissection platform. Selected reaction monitoring proteomic analysis for quantitative Her2 protein expression was performed on FFPE patient tumour tissue dissected by a laser-based instrument and the MilliSect instrument. Genomic analysis demonstrates highly confident detection of KRAS mutation specifically in lung cancer cells and not the surrounding benign, non-tumour tissue. Proteomic analysis demonstrates Her2 quantitative protein expression in breast cancer cells dissected manually, by laser-based instrumentation and by MilliSect instrumentation (mesodissection). Slide-mounted tissue dissection is commonly performed using laser-based instruments or manually scraping tissue by scalpel. Here we demonstrate that the mesodissection platform as performed by the MilliSect instrument for tissue dissection is cost-effective; it functions comparably to laser-based dissection and which can be adopted into a clinical diagnostic workflow. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Dowling, Nicki A; Merkouris, Stephanie S; Manning, Victorian; Volberg, Rachel; Lee, Stuart J; Rodda, Simone N; Lubman, Dan I
2018-06-01
Despite the over-representation of people with gambling problems in mental health populations, there is limited information available to guide the selection of brief screening instruments within mental health services. The primary aim was to compare the classification accuracy of nine brief problem gambling screening instruments (two to five items) with a reference standard among patients accessing mental health services. The classification accuracy of nine brief screening instruments was compared with multiple cut-off scores on a reference standard. Eight mental health services in Victoria, Australia. A total of 837 patients were recruited consecutively between June 2015 and January 2016. The brief screening instruments were the Lie/Bet Questionnaire, Brief Problem Gambling Screen (BPGS) (two- to five-item versions), NODS-CLiP, NODS-CLiP2, Brief Biosocial Gambling Screen (BBGS) and NODS-PERC. The Problem Gambling Severity Index (PGSI) was the reference standard. The five-item BPGS was the only instrument displaying satisfactory classification accuracy in detecting any level of gambling problem (low-risk, moderate-risk or problem gambling) (sensitivity = 0.803, specificity = 0.982, diagnostic efficiency = 0.943). Several shorter instruments adequately detected both problem and moderate-risk, but not low-risk, gambling: two three-item instruments (NODS-CLiP, three-item BPGS) and two four-item instruments (NODS-PERC, four-item BPGS) (sensitivity = 0.854-0.966, specificity = 0.901-0.954, diagnostic efficiency = 0.908-0.941). The four-item instruments, however, did not provide any considerable advantage over the three-item instruments. Similarly, the very brief (two-item) instruments (Lie/Bet and two-item BPGS) adequately detected problem gambling (sensitivity = 0.811-0.868, specificity = 0.938-0.943, diagnostic efficiency = 0.933-0.934), but not moderate-risk or low-risk gambling. The optimal brief screening instrument for mental health services wanting to screen for any level of gambling problem is the five-item Brief Problem Gambling Screen (BPGS). Services wanting to employ a shorter instrument or to screen only for more severe gambling problems (moderate-risk/problem gambling) can employ the NODS-CLiP or the three-item BPGS. Services that are only able to accommodate a very brief instrument can employ the Lie/Bet Questionnaire or the two-item BPGS. © 2017 Society for the Study of Addiction.
Buddle, BM; de Lisle, GW; Griffin, JFT; Hutchings, SA
2015-01-01
Abstract The control of tuberculosis (TB) in cattle and farmed deer in New Zealand has been greatly influenced by the existence of a wildlife reservoir of Mycobacterium bovis infection, principally the Australian brushtail possum (Trichosurus vulpecula). The reduction in possum numbers in areas with endemic M. bovis infection through vigorous vector control operations has been a major contributor to the marked reduction in the number of infected cattle and farmed deer herds in the past two decades. Management of TB in cattle and farmed deer in New Zealand has involved a combination of vector control, regionalisation of diagnostic testing of cattle and deer herds, abattoir surveillance and movement control from vector risk areas. Accurate diagnosis of infected cattle and deer has been a crucial component in the control programme. As the control programme has evolved, test requirements have changed and new tests have been introduced or test interpretations modified. Subspecific strain typing of M. bovis isolates has proved to be a valuable component in the epidemiological investigation of herd breakdowns to identify whether the source of infection was domestic livestock or wildlife. New initiatives will include the use of improved models for analysing diagnostic test data and characterising disease outbreaks leading to faster elimination of infection from herds. The introduction of the National Animal Identification Tracing programme will allow better risk profiling of individual herds and more reliable tracing of animal movements. TB in cattle and farmed deer in New Zealand can only be controlled by eliminating the disease in both domestic livestock and the wildlife reservoir. PMID:24992203
Raamanathan, Archana; Simmons, Glennon W.; Christodoulides, Nicolaos; Floriano, Pierre N.; Furmaga, Wieslaw B.; Redding, Spencer W.; Lu, Karen H.; Bast, Robert C.; McDevitt, John T.
2013-01-01
Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, modular (Programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multi-modal and multi-marker screening approaches. In the p-BNC, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a 3-D microfluidic environment, the p-BNC operating variables (incubation times, flow rates and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (Inter- and intra-assay precision of 1.2% and 1.9% and LODs of 1.0 U/mL) was achieved on this mini-sensor ensemble. Further validation with sera of ovarian cancer patients (n=20) demonstrated excellent correlation (R2 = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics. PMID:22490510
Olsen, C L; Turner, D S; Iravani, M; Waxman, K; Selam, J L; Charles, M A
1995-01-01
To evaluate the roles of 1) abdominal radiography, 2) a pressure diagnostic procedure (PDP) using a standardized diluent infusion into the catheter sideport, and 3) radiocontrast imaging of the catheter lumen as procedures for diagnosing catheter malfunction in diabetic patients implanted with a programmable intraperitoneal infusion device. Sixteen type I diabetic patients implanted with Infusaid programmable intraperitoneal insulin pumps were studied. The ability of the above three procedures to assist diagnosis of catheter malfunction and distinguish between occlusion and catheter breakage was retrospectively analyzed. Glycated hemoglobin was measured to determine the clinical importance of catheter malfunctions and decreases in pump flow due to insulin aggregation in the pump chamber. Mean glycated hemoglobin levels increased significantly from 8.0 +/- 0.3 to 9.0 +/- 0.4% (P < 0.05) before and after catheter malfunction, but not during pump flow slowdowns. Mean peak pressure during PDP was 1.96 +/- 0.14 psi (P < 0.01 vs. normal) in reversibly occluded catheters and 1.86 +/- 0.35 psi (P < 0.05 vs. normal) in broken catheters, compared with 1.32 +/- 0.23 psi in normal catheters. Decay times during PDP were > 50 s for both reversibly occluded and broken catheters (P < 0.001 vs. normal of 3.6 +/- 0.82 s). Abdominal radiographs and sideport injections of contrast material were used to distinguish the types of broken catheters. Catheter breakage and occlusion are complications in implantable insulin infusion systems and result in metabolic deterioration. The presence of a sideport allows pressure data and radiographic procedures to assist in determining the cause of catheter malfunction. A diagnostic algorithm was generated to improve efficiency in investigating catheter problems.
Raamanathan, Archana; Simmons, Glennon W; Christodoulides, Nicolaos; Floriano, Pierre N; Furmaga, Wieslaw B; Redding, Spencer W; Lu, Karen H; Bast, Robert C; McDevitt, John T
2012-05-01
Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive, and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, and modular (programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multimodal and multimarker screening approaches. In the p-BNCs, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing, and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a three-dimensional microfluidic environment, the p-BNC operating variables (incubation times, flow rates, and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (inter- and intra-assay precision of 1.2% and 1.9% and limit of detection of 1.0 U/mL) was achieved on this minisensor ensemble. Furthermore, validation with sera of patients with ovarian cancer (n = 20) showed excellent correlation (R(2) = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise, and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics.
Sereda, Magdalena; Davies, Jeff; Hall, Deborah A
2017-04-01
This report considers feasibility of conducting a UK trial of combination devices for tinnitus, using data from the study which evaluated different listener programmes available within the pre-market version of Oticon Alta with Tinnitus Sound Generator. Open and closed questions addressed the following feasibility issues: (1) Participant recruitment; (2) Device acceptability; (3) Programme preferences in different self-nominated listening situations; (4) Usability; (5) Compliance; (6) Adverse events. Eight current combination hearing aid users (all males) aged between 62-72 years (mean age 67.25 years, SD = 3.8). All eight participants reported the physical aspects and noise options on the experimental device to be acceptable. Programmes with amplification and masking features were equally preferred over the basic amplification-only programme. Individual preferences for the different programme options varied widely, both across participants and across listening situations. A set of recommendations for future trials were formulated which calls for more "real world" trial design rather than tightly controlling the fitting procedure.
Moores, B Michael
2017-06-01
A review of the role and relevance of the principles of radiation protection of the patient in diagnostic radiology as specified by ICRP has been undertaken when diagnostic risks arising from an examination are taken into account. The increase in population doses arising from diagnostic radiology over the past 20 years has been due to the widespread application of higher dose CT examinations that provide significantly more clinical information. Consequently, diagnostic risks as well as radiation risks need to be considered within the patient radiation protection framework. Justification and optimisation are discussed and the limitations imposed on patient protection by employing only a radiation risk framework is highlighted. The example of radiation protection of the patient in breast screening programmes employing mammography is used to highlight the importance of defined diagnostic outcomes in any effective radiation protection strategy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Photovoltaic array space power plus diagnostics experiment
NASA Technical Reports Server (NTRS)
Burger, D. R.
1990-01-01
The objective is to summarize the five years of hardware development and fabrication represented by the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) Instrument. The original PASP Experiment requirements and background is presented along with the modifications which were requested to transform the PASP Experiment into the PASP Plus Instrument. The PASP Plus hardware and software is described. Test results for components and subsystems are given as well as final system tests. Also included are appendices which describe the major subsystems and present supporting documentation such as block diagrams, schematics, circuit board artwork, drawings, test procedures and test reports.
Roets-Merken, Lieve M; Zuidema, Sytse U; Vernooij-Dassen, Myrra J F J; Teerenstra, Steven; Hermsen, Pieter G J M; Kempen, Gertrudis I J M; Graff, Maud J L
2018-01-24
To evaluate the effectiveness of a nurse-supported self-management programme to improve social participation of dual sensory impaired older adults in long-term care homes. Cluster randomised controlled trial. Thirty long-term care homes across the Netherlands. Long-term care homes were randomised into intervention clusters (n=17) and control clusters (n=13), involving 89 dual sensory impaired older adults and 56 licensed practical nurses. Nurse-supported self-management programme. Effectiveness was evaluated by the primary outcome social participation using a participation scale adapted for visually impaired older adults distinguishing four domains: instrumental activities of daily living, social-cultural activities, high-physical-demand and low-physical-demand leisure activities. A questionnaire assessing hearing-related participation problems was added as supportive outcome. Secondary outcomes were autonomy, control, mood and quality of life and nurses' job satisfaction. For effectiveness analyses, linear mixed models were used. Sampling and intervention quality were analysed using descriptive statistics. Self-management did not affect all four domains of social participation; however. the domain 'instrumental activities of daily living' had a significant effect in favour of the intervention group (P=0.04; 95% CI 0.12 to 8.5). Sampling and intervention quality was adequate. A nurse-supported self-management programme was effective in empowering the dual sensory impaired older adults to address the domain 'instrumental activities of daily living', but no differences were found in addressing the other three participation domains. Self-management showed to be beneficial for managing practical problems, but not for those problems requiring behavioural adaptations of other persons. NCT01217502; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Digital Technologies Jump Start Telemedicine
ERIC Educational Resources Information Center
Pierce, Alan
2011-01-01
The technologists, research doctors, computer programmers, electrical engineers, and biomedical engineers who design and create new medical diagnostic equipment and medical treatments are now working on medical systems that use the computing power of personal computers and cell phones. For disease diagnosis, they are finding ways to shrink…
[Controlling instruments in radiology].
Maurer, M
2013-10-01
Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.
A novel quality assurance method in a university teaching paediatric radiology department.
Gallet, J M; Reed, M H; Hlady, J
2000-08-01
Primary diagnostic equipment in a paediatric radiology department must perform at optimal levels at all times. The Children's Hospital Radiology Department in Winnipeg, Canada, has developed an impartial means of reporting radiographic image quality. The main objectives of this study programme were two-fold. First, to monitor diagnostic X-ray equipment performance, and second, to improve the resultant image quality as a means of implementing the fundamental concepts of continuous quality improvement. Reading radiologists completed a quality assurance (QA) card when they identified a radiographic image quality problem. The cards were subsequently collected by the clinical instructor who then informed, in confidence, the radiographers of the written comments or concerns. QA cards have been conspicuously installed in the paediatric radiology reading room since the middle of 1993. Since its inception, equipment malfunction has been monitored and indicators for improving image quality developed. This component of the QA programme has shown itself to be a successful means of communicating with radiographers in maintaining superior image quality.
Programmable diagnostic devices made from paper and tape.
Martinez, Andres W; Phillips, Scott T; Nie, Zhihong; Cheng, Chao-Min; Carrilho, Emanuel; Wiley, Benjamin J; Whitesides, George M
2010-10-07
This paper describes three-dimensional microfluidic paper-based analytical devices (3-D microPADs) that can be programmed (postfabrication) by the user to generate multiple patterns of flow through them. These devices are programmed by pressing single-use 'on' buttons, using a stylus or a ballpoint pen. Pressing a button closes a small space (gap) between two vertically aligned microfluidic channels, and allows fluids to wick from one channel to the other. These devices are simple to fabricate, and are made entirely out of paper and double-sided adhesive tape. Programmable devices expand the capabilities of microPADs and provide a simple method for controlling the movement of fluids in paper-based channels. They are the conceptual equivalent of field-programmable gate arrays (FPGAs) widely used in electronics.
Linden, Ariel; Adams, John L; Roberts, Nancy
2006-04-01
Although disease management (DM) has been in existence for over a decade, there is still much uncertainty as to its effectiveness in improving health status and reducing medical cost. The main reason is that most programme evaluations typically follow weak observational study designs that are subject to bias, most notably selection bias and regression to the mean. The regression discontinuity (RD) design may be the best alternative to randomized studies for evaluating DM programme effectiveness. The most crucial element of the RD design is its use of a 'cut-off' score on a pre-test measure to determine assignment to intervention or control. A valuable feature of this technique is that the pre-test measure does not have to be the same as the outcome measure, thus maximizing the programme's ability to use research-based practice guidelines, survey instruments and other tools to identify those individuals in greatest need of the programme intervention. Similarly, the cut-off score can be based on clinical understanding of the disease process, empirically derived, or resource-based. In the RD design, programme effectiveness is determined by a change in the pre-post relationship at the cut-off point. While the RD design is uniquely suitable for DM programme evaluation, its success will depend, in large part, on fundamental changes being made in the way DM programmes identify and assign individuals to the programme intervention.
NASA Astrophysics Data System (ADS)
Tho, Siew Wei; Chan, Ka Wing; Yeung, Yau Yuen
2015-10-01
In this study, a new physics education programme is specifically developed for a famous theme park in Hong Kong to provide community-based science learning to her visitors, involving her three newly constructed rides. We make innovative use of digital technologies in this programme and incorporate a rigorous evaluation of the learning effectiveness of the programme. A total of around 200 students from nine local secondary schools participated in both the physics programme and its subsequent evaluation which consists of a combination of research and assessment tools, including pre- and post-multiple-choice tests, a questionnaire survey and an interview as specifically developed for this programme, or adopted from some well-accepted research instruments. Based on the evaluation of students' academic performance, there are two educationally significant findings on enhancing the students' physics learning: (a) traditionally large gender differences in physics performance and interest of learning are mostly eliminated; and (b) a less-exciting ride called the aviator (instead of the most exciting roller-coaster ride) can induce the largest learning effect (or gain in academic performance) amongst teenagers. Besides, findings from the questionnaire survey and interviews of participants are reported to reveal their views, perceptions, positive and negative comments or feedback on this programme which could provide valuable insights for future development of other similar community-based programmes.
["Operationalised psychodynamic diagnostics in childhood and adolescence" (OPD-CA) in practice].
Schulte-Markwort, Michael; Resch, Franz; Bürgin, Dieter
2004-02-01
"Operationalised psychodynamic diagnostics in childhood and adolescence" (OPD-CA) has been completed in its first version after years of development. In a first interview with a 13-year-old boy, the diagnostic instruments of OPD-CA are presented by means of examples. The text passages of the transcribed first interview are evaluated in four sections by representatives of the respective working groups regarding the axes--relationships, conflict, structure and preconditions for treatment--and the diagnostic conclusions resulting from this are presented, thus providing a direct insight into the specific psychodynamic diagnostics of OPD-CA.
An FPGA-based instrumentation platform for use at deep cryogenic temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conway Lamb, I. D.; Colless, J. I.; Hornibrook, J. M.
2016-01-15
We describe the operation of a cryogenic instrumentation platform incorporating commercially available field-programmable gate arrays (FPGAs). The functionality of the FPGAs at temperatures approaching 4 K enables signal routing, multiplexing, and complex digital signal processing in close proximity to cooled devices or detectors within the cryostat. The performance of the FPGAs in a cryogenic environment is evaluated, including clock speed, error rates, and power consumption. Although constructed for the purpose of controlling and reading out quantum computing devices with low latency, the instrument is generic enough to be of broad use in a range of cryogenic applications.
Controller for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument
NASA Technical Reports Server (NTRS)
Zomberg, Brian G.; Chren, William A., Jr.
1994-01-01
A prototype controller for the ESTAR (electronically scanned thinned array radiometer) instrument has been designed and tested. It manages the operation of the digital data subsystem (DDS) and its communication with the Small Explorer data system (SEDS). Among the data processing tasks that it coordinates are FEM data acquisition, noise removal, phase alignment and correlation. Its control functions include instrument calibration and testing of two critical subsystems, the output data formatter and Walsh function generator. It is implemented in a Xilinx XC3064PC84-100 field programmable gate array (FPGA) and has a maximum clocking frequency of 10 MHz.
Expert Systems Based Clinical Assessment and Tutorial Project.
ERIC Educational Resources Information Center
Papa, Frank; Shores, Jay
This project at the Texas College of Osteopathic Medicine (Fort Worth) evaluated the use of an artificial-intelligence-derived measure, "Knowledge-Based Inference Tool" (KBIT), as the basis for assessing medical students' diagnostic capabilities and designing instruction to improve diagnostic skills. The instrument was designed to…
78 FR 75362 - Notice of Issuance of Final Determination Concerning Docave Computer Software
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-11
... in whole or in part of materials from another country or instrumentality, it has been substantially... programming of a foreign PROM (Programmable Read-Only Memory chip) in the United States substantially...
ERIC Educational Resources Information Center
Andersen, Lisa M. J.; Naswall, Katharina; Manouilenko, Irina; Nylander, Lena; Edgar, Johan; Ritvo, Riva Ariella; Ritvo, Edward; Bejerot, Susanne
2011-01-01
There is a paucity of diagnostic instruments for adults with autism spectrum disorder (ASD). This study evaluates the psychometric properties of the Swedish version of the Ritvo Autism and Asperger Diagnostic Scale-Revised (RAADS-R), an 80-item self-rating scale designed to assist clinicians diagnosing ASD in adults. It was administered to 75…
A Combined Fabrication and Instrumentation Platform for Sample Preparation.
Guckenberger, David J; Thomas, Peter C; Rothbauer, Jacob; LaVanway, Alex J; Anderson, Meghan; Gilson, Dan; Fawcett, Kevin; Berto, Tristan; Barrett, Kevin; Beebe, David J; Berry, Scott M
2014-06-01
While potentially powerful, access to molecular diagnostics is substantially limited in the developing world. Here we present an approach to reduced cost molecular diagnostic instrumentation that has the potential to empower developing world communities by reducing costs through streamlining the sample preparation process. In addition, this instrument is capable of producing its own consumable devices on demand, reducing reliance on assay suppliers. Furthermore, this instrument is designed with an "open" architecture, allowing users to visually observe the assay process and make modifications as necessary (as opposed to traditional "black box" systems). This open environment enables integration of microfluidic fabrication and viral RNA purification onto an easy-to-use modular system via the use of interchangeable trays. Here we employ this system to develop a protocol to fabricate microfluidic devices and then use these devices to isolate viral RNA from serum for the measurement of human immunodeficiency virus (HIV) viral load. Results obtained from this method show significantly reduced error compared with similar nonautomated sample preparation processes. © 2014 Society for Laboratory Automation and Screening.
NASA Astrophysics Data System (ADS)
Jauhariyah, M. N. R.; Zulfa, I.; Harizah, Z.; Setyarsih, W.
2018-04-01
In the learning process, students still have misconceptions although the concept has been taught by the teacher. One of the causes of misconceptions comes from the students themselves. The teacher often does not know that students have misconceptions because the assessment that has been given does not review the cause of misconception that occurs in students. Students have misconception especially in Abstract concept like in chapter Kinetic Theory of Gases. Because of that, this study made three tier diagnostic instrument test to diagnose student’s misconception in chapter Kinetic Theory of Gases. Moreover, it is also done an analysis in order to know the quality of instrument that has been made. According to the trials, the percentage of average internal validity is about 84.6% which means it is in proper to use and the reliability of instrument is 0.752, meaning reliable to use. This instrument used to diagnose the students’ misconceptions on chapter Kinetic Theory of Gases.
Real-time plasma control based on the ISTTOK tomography diagnostica)
NASA Astrophysics Data System (ADS)
Carvalho, P. J.; Carvalho, B. B.; Neto, A.; Coelho, R.; Fernandes, H.; Sousa, J.; Varandas, C.; Chávez-Alarcón, E.; Herrera-Velázquez, J. J. E.
2008-10-01
The presently available processing power in generic processing units (GPUs) combined with state-of-the-art programmable logic devices benefits the implementation of complex, real-time driven, data processing algorithms for plasma diagnostics. A tomographic reconstruction diagnostic has been developed for the ISTTOK tokamak, based on three linear pinhole cameras each with ten lines of sight. The plasma emissivity in a poloidal cross section is computed locally on a submillisecond time scale, using a Fourier-Bessel algorithm, allowing the use of the output signals for active plasma position control. The data acquisition and reconstruction (DAR) system is based on ATCA technology and consists of one acquisition board with integrated field programmable gate array (FPGA) capabilities and a dual-core Pentium module running real-time application interface (RTAI) Linux. In this paper, the DAR real-time firmware/software implementation is presented, based on (i) front-end digital processing in the FPGA; (ii) a device driver specially developed for the board which enables streaming data acquisition to the host GPU; and (iii) a fast reconstruction algorithm running in Linux RTAI. This system behaves as a module of the central ISTTOK control and data acquisition system (FIRESIGNAL). Preliminary results of the above experimental setup are presented and a performance benchmarking against the magnetic coil diagnostic is shown.
ERIC Educational Resources Information Center
Wang, Jing-Ru
2004-01-01
This study is intended to develop an assessment instrument to investigate students' understandings about internal transport in plants and human circulatory system. A refined process of a two-tier diagnostic test was used to develop the instrument. Finally, three versions of the Internal Transport in Plants and the Human Circulatory System test…
Combined raman spectrometer/laser-induced breakdown spectrometer design concept
NASA Astrophysics Data System (ADS)
Bazalgette Courrèges-Lacoste, Gregory; Ahlers, Berit; Boslooper, Erik; Rull-Perez, Fernando; Maurice, Sylvestre
2017-11-01
Amongst the different instruments that have been preselected to be on-board the Pasteur payload on ExoMars is the Raman/ Laser Induced Breakdown Spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman Spectrometer/ LIBS Elegant Bread-Board (EBB). The instrument is based on a specifically designed extremely compact spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and resources are the main drivers of the instrument's design concept. The proposed design concept, realization and testing programme for the combined Raman/ LIBS EBB is presented as well as background information on Raman and LIBS.
Thiam, Sylla; Thior, Moussa; Faye, Babacar; Ndiop, Médoune; Diouf, Mamadou Lamine; Diouf, Mame Birame; Diallo, Ibrahima; Fall, Fatou Ba; Ndiaye, Jean Louis; Albertini, Audrey; Lee, Evan; Jorgensen, Pernille; Gaye, Oumar; Bell, David
2011-01-01
Background While WHO recently recommended universal parasitological confirmation of suspected malaria prior to treatment, debate has continued as to whether wide-scale use of rapid diagnostic tests (RDTs) can achieve this goal. Adherence of health service personnel to RDT results has been poor in some settings, with little impact on anti-malarial drug consumption. The Senegal national malaria control programme introduced universal parasite-based diagnosis using malaria RDTs from late 2007 in all public health facilities. This paper assesses the impact of this programme on anti-malarial drug consumption and disease reporting. Methods and Findings Nationally-collated programme data from 2007 to 2009 including malaria diagnostic outcomes, prescription of artemisinin-based combination therapy (ACT) and consumption of RDTs in public health facilities, were reviewed and compared. Against a marked seasonal variation in all-cause out-patient visits, non-malarial fever and confirmed malaria, parasite-based diagnosis increased nationally from 3.9% of reported malaria-like febrile illness to 86.0% over a 3 year period. The prescription of ACT dropped throughout this period from 72.9% of malaria-like febrile illness to 31.5%, reaching close equivalence to confirmed malaria (29.9% of 584873 suspect fever cases). An estimated 516576 courses of inappropriate ACT prescription were averted. Conclusions The data indicate high adherence of anti-malarial prescribing practice to RDT results after an initial run-in period. The large reduction in ACT consumption enabled by the move from symptom-based to parasite-based diagnosis demonstrates that effective roll-out and use of malaria RDTs is achievable on a national scale through well planned and structured implementation. While more detailed information on management of parasite-negative cases is required at point of care level to assess overall cost-benefits to the health sector, considerable cost-savings were achieved in ACT procurement. Programmes need to be allowed flexibility in management of these funds to address increases in other programmatic costs that may accrue from improved diagnosis of febrile disease. PMID:21494674
The impact of a leadership development programme on nurses' self-perceived leadership capability.
Paterson, Karyn; Henderson, Amanda; Burmeister, Elizabeth
2015-11-01
This paper reports on the outcomes of a locally designed educational programme to support leadership capability of junior registered nurses. The Developing Leader Programme is an in-house programme delivered in three face-to-face workshops, comprising self-directed reflective and application activities. Surveys were used to evaluate self-perceived leadership capability over a 9-month period. The survey comprised a Leadership Capability Instrument adapted from two existing tools. Participants completed surveys at the commencement of the programme, after the third and final workshop and approximately 6 months afterwards. In addition, examples of descriptive accounts of programme activities submitted by individual participants were included to enrich data. Of 124 participants, 79 completed surveys at the first workshop, 28 at the final workshop and 31 were returned 6 months after completion of the programme. Mean scores for each area of leadership capability significantly improved throughout the duration of the programme (P < 0.001). Participants also indicated a willingness to enact leadership behaviours through reported activities. Survey responses indicated that participants perceived improved leadership capability after completing the Developing Leader Programme. Early educational intervention to facilitate the development of leadership skills as well as clinical skills in junior registered nurses can assist with how they interact with the team. Participation of junior registered nurses in a locally designed leadership programme can assist them to develop leadership behaviours for everyday practice. © 2014 John Wiley & Sons Ltd.
The influence of parental concern on the utility of autism diagnostic instruments.
Havdahl, Karoline Alexandra; Bishop, Somer L; Surén, Pål; Øyen, Anne-Siri; Lord, Catherine; Pickles, Andrew; von Tetzchner, Stephen; Schjølberg, Synnve; Gunnes, Nina; Hornig, Mady; Lipkin, W Ian; Susser, Ezra; Bresnahan, Michaeline; Magnus, Per; Stenberg, Nina; Reichborn-Kjennerud, Ted; Stoltenberg, Camilla
2017-10-01
The parental report-based Autism Diagnostic Interview-Revised (ADI-R) and the clinician observation-based Autism Diagnostic Observation Schedule (ADOS) have been validated primarily in U.S. clinics specialized in autism spectrum disorder (ASD), in which most children are referred by their parents because of ASD concern. This study assessed diagnostic agreement of the ADOS-2 and ADI-R toddler algorithms in a more broadly based sample of 679 toddlers (age 35-47 months) from the Norwegian Mother and Child Cohort. We also examined whether parental concern about ASD influenced instrument performance, comparing toddlers identified based on parental ASD concern (n = 48) and parent-reported signs of developmental problems (screening) without a specific concern about ASD (n = 400). The ADOS cutoffs showed consistently well-balanced sensitivity and specificity. The ADI-R cutoffs demonstrated good specificity, but reduced sensitivity, missing 43% of toddlers whose parents were not specifically concerned about ASD. The ADI-R and ADOS dimensional scores agreed well with clinical diagnoses (area under the curve ≥ 0.85), contributing additively to their prediction. On the ADI-R, different cutoffs were needed according to presence or absence of parental ASD concern, in order to achieve comparable balance of sensitivity and specificity. These results highlight the importance of taking parental concern about ASD into account when interpreting scores from parental report-based instruments such as the ADI-R. While the ADOS cutoffs performed consistently well, the additive contributions of ADI-R and ADOS scores to the prediction of ASD diagnosis underscore the value of combining instruments based on parent accounts and clinician observation in evaluation of ASD. Autism Res 2017, 10: 1672-1686. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.
Dogs have been studied for many years as a medical diagnostic tool to detect a pre-clinical disease state by sniffing emissions directly from a human or an in vitro biological sample. Some of the studies report high sensitivity and specificity in blinded case-control studies. How...
Noise level measurements on the UMTA Mark I Diagnostic Car (R42 MODEL)
DOT National Transportation Integrated Search
1971-10-01
The R42 Model mass transit car currently operating on the "N" line of the new York City Transit System was selected for experimentation and tests. For this purpose, the car was instrumented and designated as the UMTA Mark I Diagnostic Car. Noise leve...
Enhancing ADHD and LD Diagnostic Accuracy Using Career Instruments
ERIC Educational Resources Information Center
Dipeolu, Abiola; Hargrave, Stephanie; Storlie, Cassandra A.
2015-01-01
Individuals diagnosed with mental health disorders may have work-related difficulties that impact functioning in all life domains. With limited research on the integration of career and mental health counseling, authors used a discriminant function analysis to assess the predictability of accurately identifying diagnostic categories among 258…
Assessing Clinical Reasoning (ASCLIRE): Instrument Development and Validation
ERIC Educational Resources Information Center
Kunina-Habenicht, Olga; Hautz, Wolf E.; Knigge, Michel; Spies, Claudia; Ahlers, Olaf
2015-01-01
Clinical reasoning is an essential competency in medical education. This study aimed at developing and validating a test to assess diagnostic accuracy, collected information, and diagnostic decision time in clinical reasoning. A norm-referenced computer-based test for the assessment of clinical reasoning (ASCLIRE) was developed, integrating the…
The Development of a Vocational Diagnostic Program. Interim Report.
ERIC Educational Resources Information Center
Barnard, William W.
A five-phased project is described which was designed to develop more specific diagnostic procedures and instrumentation that would allow both the vocational counselor and the prospective student to determine more effectively specific occupational programs and occupational objectives for education at the postsecondary level. Phases of the project…
View of the Challenger's payload bay and the Plasma Diagnostic package
1985-08-01
51F-33-024 (29 July-6 Aug 1985) --- The Challenger's remote manipulator system (RMS) arm grasps the plasma diagnostics package (PDP) over the experiment-laden cargo bay of the earth orbiting spacecraft. The instrument pointing system, in a resting mode here, is prominent in the bay.
Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.
Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes
2017-03-01
Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.
Westen, D
1997-07-01
The purpose of this study was to examine the extent to which instruments for assessing axis II diverge from clinical diagnostic processes. Subjects in the first study were 52 clinicians with experience in assessment and treatment of patients with personality disorders, who were surveyed about the methods they use in clinical practice to make diagnoses and other aspects of the diagnostic process. A second study replicated the major findings with a random national sample of 1,901 experienced psychiatrists and psychologists. Whereas current instruments rely primarily on direct questions derived from DSM-IV, clinicians of every theoretical persuasion found direct questions useful for assessing axis I disorders but only marginally so for axis II. They made axis II diagnoses, instead, by listening to patients describe interpersonal interactions and observing their behavior with the interviewer. In contrast to findings with current research instruments, most patients with personality disorders in clinical practice receive only one axis II diagnosis, and if they receive more than one, one is considered primary. Clinicians reported treating a substantial number of patients for enduring personality patterns that current axis II instruments do not assess, many of which meet neither axis I nor axis II criteria, notably problems with relatedness, work, self-esteem, and chronic subclinical depressive traits. Measurements of axis II were constructed by using a model derived from axis I instruments that diverges from clinical diagnostic procedures in a way that may be problematic for the assessment of personality disorders and the development of a more clinically and empirically sound taxonomy.
Autism Spectrum Disorder in Sub-Saharan Africa: A Comprehensive Scoping Review
Franz, Lauren; Chambers, Nola; von Isenburg, Megan; de Vries, Petrus J.
2017-01-01
Autism spectrum disorder (ASD) is recognized as a global public health concern, yet almost everything we know about ASD comes from high-income countries. Here we performed a scoping review of all research on ASD ever published in sub-Saharan Africa (SSA) in order to identify ASD knowledge gaps in this part of the world. Fifty-three publications met inclusion criteria. Themes included the phenotype, genetics and risk factors for ASD in SSA, screening and diagnosis, professional knowledge, interventions for ASD, parental perceptions, and social-cognitive neuroscience. No epidemiological, early intervention, school-based or adult studies were identified. For each identified theme, we aimed to summarize results and make recommendations to fill the knowledge gaps. The quality of study methodologies was generally not high. Few studies used standardized diagnostic instruments, and intervention studies were typically small-scale. Overall, findings suggest a substantial need for large-scale clinical, training, and research programmes to improve the lives of people who live with ASD in SSA. However, SSA also has the potential to make unique and globally-significant contributions to the etiology and treatments of ASD through implementation, interventional, and comparative genomic science. PMID:28266791
A Michelson Interferometer for Electron Cyclotron Emission Measurements on EAST
NASA Astrophysics Data System (ADS)
Liu, Yong; Stefan, Schmuck; Zhao, Hailin; John, Fessey; Paul, Trimble; Liu, Xiang; Zhu, Zeying; Zang, Qing; Hu, Liqun
2016-12-01
A Michelson interferometer, on loan from EFDA-JET (Culham, United Kingdom) has recently been commissioned on the experimental advanced superconducting tokamak (EAST, ASIPP, Hefei, China). Following a successful in-situ absolute calibration the instrument is able to measure the electron cyclotron emission (ECE) spectrum, from 80 GHz to 350 GHz in extraordinary mode (X-mode) polarization, with high accuracy. This allows the independent determination of the electron temperature profile from observation of the second harmonic ECE and the possible identification of non-Maxwellian features by comparing higher harmonic emission with numerical simulations. The in-situ calibration results are presented together with the initial measured temperature profiles. These measurements are then discussed and compared with other independent temperature profile measurements. This paper also describes the main hardware features of the diagnostic and the associated commissioning test results. supported by National Natural Science Foundation of China (Nos. 11405211, 11275233), and the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB106002, 2015GB101000), and the RCUK Energy Programme (No. EP/I501045), partly supported by the JSPS-NRF-NSFC A3 Foresight Program in the Field of Plasma Physics (NSFC: No. 11261140328)
Dziewas, Rainer; Glahn, Jörg; Helfer, Christine; Ickenstein, Guntram; Keller, Jochen; Ledl, Christian; Lindner-Pfleghar, Beate; G Nabavi, Darius; Prosiegel, Mario; Riecker, Axel; Lapa, Sriramya; Stanschus, Sönke; Warnecke, Tobias; Busse, Otto
2016-02-25
Neurogenic dysphagia is one of the most frequent and prognostically relevant neurological deficits in a variety of disorders, such as stroke, parkinsonism and advanced neuromuscular diseases. Flexible endoscopic evaluation of swallowing (FEES) is now probably the most frequently used tool for objective dysphagia assessment in Germany. It allows evaluation of the efficacy and safety of swallowing, determination of appropriate feeding strategies and assessment of the efficacy of different swallowing manoeuvres. The literature furthermore indicates that FEES is a safe and well-tolerated procedure. In spite of the huge demand for qualified dysphagia diagnostics in neurology, a systematic FEES education has not yet been established. The structured training curriculum presented in this article aims to close this gap and intends to enforce a robust and qualified FEES service. As management of neurogenic dysphagia is not confined to neurologists, this educational programme is applicable to other clinicians and speech-language therapists with expertise in dysphagia as well. The systematic education in carrying out FEES across a variety of different professions proposed by this curriculum will help to spread this instrumental approach and to improve dysphagia management.
Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.
Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T
2016-01-01
We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.
Evaluating ethics competence in medical education.
Savulescu, J; Crisp, R; Fulford, K W; Hope, T
1999-01-01
We critically evaluate the ways in which competence in medical ethics has been evaluated. We report the initial stage in the development of a relevant, reliable and valid instrument to evaluate core critical thinking skills in medical ethics. This instrument can be used to evaluate the impact of medical ethics education programmes and to assess whether medical students have achieved a satisfactory level of performance of core skills and knowledge in medical ethics, within and across institutions. PMID:10536759
Sharp, Linda; Tilson, Lesley; Whyte, Sophie; Ceilleachair, Alan O; Walsh, Cathal; Usher, Cara; Tappenden, Paul; Chilcott, James; Staines, Anthony; Barry, Michael; Comber, Harry
2013-03-19
Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55-74 years, and (c) biennial faecal immunochemical tests (FIT) at 55-74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55-64 years) and staggered age-based roll-out across the 55-74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55-74). FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381-1,053 with FSIG-based, and 967-1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning.
Tommasini, Cristina; Dobrowolska, Beata; Zarzycka, Danuta; Bacatum, Claudia; Bruun, Anne Marie Gran; Korsath, Dag; Roel, Siv; Jansen, Mette Bro; Milling, Tine; Deschamps, Anne; Mantzoukas, Stefanos; Mantzouka, Christine; Palese, Alvisa
2017-04-01
Assessing clinical competence in nursing students abroad is a challenge, and requires both methods and instruments capable of capturing the multidimensional nature of the clinical competences acquired. The aim of the study was to compare the clinical competence assessment processes and instruments adopted for nursing students during their clinical placement abroad. A case study design was adopted in 2015. A purposeful sample of eight nursing programmes located in seven countries (Belgium, Denmark, Greece, Norway, Poland, Portugal and Italy) were approached. Tools as instruments for evaluating competences developed in clinical training by international nursing students, and written procedures aimed at guiding the evaluation process, were scrutinised through a content analysis method. All clinical competence evaluation procedures and instruments used in the nursing programmes involved were provided in English. A final evaluation of the competences was expected by all nursing programmes at the end of the clinical placement, while only four provided an intermediate evaluation. Great variability emerged in the tools, with between five and 88 items included. Through content analysis, 196 items emerged, classified into 12 different core competence categories, the majority were categorised as 'Technical skills' (=60), 'Self-learning and critical thinking' (=27) and 'Nursing care process' (=25) competences. Little emphasis was given in the tools to competences involving 'Self-adaptation', 'Inter-professional skills', 'Clinical documentation', 'Managing nursing care', 'Patient communication', and 'Theory and practice integration'. Institutions signing Bilateral Agreements should agree upon the competences expected from students during their clinical education abroad. The tools used in the process, as well as the role expected by the student, should also be agreed upon. Intercultural competences should be further addressed in the process of evaluation, in addition to adaptation to different settings. There is also a need to establish those competences achievable or not in the host country, aiming at increasing transparency in learning expectations and evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.
The development of a clinical outcomes survey research application: Assessment Center.
Gershon, Richard; Rothrock, Nan E; Hanrahan, Rachel T; Jansky, Liz J; Harniss, Mark; Riley, William
2010-06-01
The National Institutes of Health sponsored Patient-Reported Outcome Measurement Information System (PROMIS) aimed to create item banks and computerized adaptive tests (CATs) across multiple domains for individuals with a range of chronic diseases. Web-based software was created to enable a researcher to create study-specific Websites that could administer PROMIS CATs and other instruments to research participants or clinical samples. This paper outlines the process used to develop a user-friendly, free, Web-based resource (Assessment Center) for storage, retrieval, organization, sharing, and administration of patient-reported outcomes (PRO) instruments. Joint Application Design (JAD) sessions were conducted with representatives from numerous institutions in order to supply a general wish list of features. Use Cases were then written to ensure that end user expectations matched programmer specifications. Program development included daily programmer "scrum" sessions, weekly Usability Acceptability Testing (UAT) and continuous Quality Assurance (QA) activities pre- and post-release. Assessment Center includes features that promote instrument development including item histories, data management, and storage of statistical analysis results. This case study of software development highlights the collection and incorporation of user input throughout the development process. Potential future applications of Assessment Center in clinical research are discussed.
NASA Astrophysics Data System (ADS)
Vacas-Jacques, Paulino; Linnes, Jacqueline; Young, Anna; Gerrard, Victoria; Gomez-Marquez, Jose
2014-03-01
Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.
Agreement between a Brief Autism Observational Instrument and Established ASD Measures
ERIC Educational Resources Information Center
Ward, Samantha L.; Sullivan, Karen A.; Gilmore, Linda
2016-01-01
Objective: Limited time and resources necessitate the availability of accurate, inexpensive and rapid diagnostic aids for Autism Spectrum Disorder (ASD). The Autistic Behavioural Indicators Instrument (ABII) was developed for this purpose, but its psychometric properties have not yet been fully established. Method: The clinician-rated ABII, the…
ERIC Educational Resources Information Center
Curtis, David D.; Boman, Peter
2007-01-01
By using the Rasch model, much detailed diagnostic information is available to developers of survey and assessment instruments and to the researchers who use them. We outline an approach to the analysis of data obtained from the administration of survey instruments that can enable researchers to recognise and diagnose difficulties with those…
International recognition of basic medical education programmes.
Karle, Hans
2008-01-01
This document aims to formulate a World Federation for Medical Education (WFME) policy and to open debate on the subject on international recognition of basic medical education institutions and programmes. We carried out a systematic review of international quality assurance of medical education and recognition methodology, including accreditation procedures and alternative quality assurance methods, with a focus on the role of the WFME in international recognition of basic medical education programmes. In order to further the intentions of the WFME, the Federation will: continue its activity to establish new Global Directories of Health Professions Education Institutions (GDHPEI); set up a planning working group to prepare the work of the international advisory committee for GDHPEI; develop a database of relevant accrediting and recognising agencies; continue its project on the promotion of proper national accreditation; establish a working group to develop principles to be used in the evaluation of medical schools and other health professions education institutions and their programmes for the purpose of international recognition, especially when proper accreditation is not feasible, and work with partners on training programmes for advisors and assessors. The new directory for medical schools, which will include qualitative information about basic medical education programmes, will provide a basis for the meta-recognition of medical schools' programmes by stimulating the establishment of national accreditation systems and other quality assurance instruments.
Programmable architecture for pixel level processing tasks in lightweight strapdown IR seekers
NASA Astrophysics Data System (ADS)
Coates, James L.
1993-06-01
Typical processing tasks associated with missile IR seeker applications are described, and a straw man suite of algorithms is presented. A fully programmable multiprocessor architecture is realized on a multimedia video processor (MVP) developed by Texas Instruments. The MVP combines the elements of RISC, floating point, advanced DSPs, graphics processors, display and acquisition control, RAM, and external memory. Front end pixel level tasks typical of missile interceptor applications, operating on 256 x 256 sensor imagery, can be processed at frame rates exceeding 100 Hz in a single MVP chip.
Nanda, P
1999-08-01
Within the overall aim of poverty alleviation, development efforts have included credit and self-employment programmes. In Bangladesh, the major beneficiaries of such group-based credit programmes are rural women who use the loans to initiate small informal income-generating activities. This paper explores the benefits of women's participation in credit programmes on their own health seeking. Using data from a sample of 1798 households from rural Bangladesh, conducted in 1991-1992 through repeated random sampling of 87 districts covered by Grameen Bank, Bangladesh Rural Advancement Committee (BRAC) and Bangladesh Rural Development Board (BRDB), this paper addresses the question: does women's participation in credit programmes significantly affect their use of formal health care? A non-unitary household preference model is suggested to test the hypothesis that women's empowerment through participation in these programmes results in greater control of resources for their own demand for formal health care. The analysis controls for endogeneity due to self-selection and other unobserved village level factors through the use of a weighted two stage instrumental variable approach with village level fixed effects. The findings indicate a positive impact of women's participation in credit programmes on their demand for formal health care. The policy simulations on the results of this study highlight the importance of credit programmes as a health intervention in addition to being a mechanism for women's economic empowerment.
Brown, Sydney E S; Chin, Marshall H; Huang, Elbert S
2007-08-01
Outpatient healthcare organisations worldwide participate in quality improvement (QI) programmes. Despite the importance of understanding the financial impact of such programmes, there are no established standard methods for empirically assessing QI programme costs and their consequences for small outpatient healthcare organisations. The costs and cost consequences were evaluated for a diabetes QI programme implemented throughout the USA in federally qualified community health centres. For five case study centres, survey instruments and methods for data analysis were developed. Two types of cost/revenue were evaluated. Direct costs/revenues, such as personnel time, items purchased and grants received, were evaluated using self-administered surveys. Cost/revenue consequences, which were cost/revenue changes that may have occurred due to changes in patient utilisation or physician behaviour, were evaluated using electronic billing data. Other methods for evaluating cost/revenue consequences if electronic billing data are not available are also discussed. This paper describes a practical taxonomy and method for assessing the costs and revenues of QI programmes for outpatient organisations. Results of such analyses will be useful for healthcare organisations implementing QI programmes and also for policy makers designing incentives for QI participation.
NASA Astrophysics Data System (ADS)
Lee, Yew-Jin; Chue, Shien
2013-10-01
School-based curriculum innovations, including those in science education, are usually not adequately evaluated, if at all. Furthermore, current procedures and instruments for programme evaluations are often unable to support evidence-based decision-making. We suggest that adopting fidelity of implementation (FOI) criteria from healthcare research can both characterize and narrow the separation between programme intent and actual implementation, which is a mandatory stage of evaluation before determining overall programme value. We demonstrate how such a process could be applied by science educators using data from a secondary school in Singapore that had devised a new curriculum to promote interest, investigative processes, and knowledge in science. Results showed that there were ambivalent student responses to this programme, while there were high levels of science process skill instruction and close alignment with the intended lesson design. The implementation of this programme appeared to have a satisfactory overall level of FOI, but we also detected tensions between programme intent and everyday classroom teaching. If we want to advance science education, then our argument is that applying FOI criteria is necessary when evaluating all curricular innovations, not just those that originate from schools.
Dynamic Stability Instrumentation System (DSIS). Volume 3; User Manual
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.; Boyden, Richmond P.; Dress, David A.; Jordan, Thomas L.
1996-01-01
The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.
Quality of nursing diagnoses: evaluation of an educational intervention.
Florin, Jan; Ehrenberg, Anna; Ehnfors, Margareta
2005-01-01
To investigate the effects on the quality of nursing diagnostic statements in patient records after education in the nursing process and implementation of new forms for recording. Quasi-experimental design. Randomly selected patient records reviewed before and after intervention from one experimental unit (n = 70) and three control units (n = 70). A scale with 14 characteristics pertaining to nursing diagnoses was developed and used together with the instrument (CAT-CH-ING) for record review. Quality of nursing diagnostic statements improved in the experimental unit, whereas no improvement was found in the control units. Serious flaws in the use of the etiology component were found. CONCLUSION. Nurses must be more concerned with the accuracy and quality of the nursing diagnoses and the etiology component needs to be given special attention. Education of RNs in nursing diagnostic statements and peer review using standardized evaluation instruments can be means to further enhance RNs' documentation practice.
Thioaptamer Diagnostic System (TDS)
NASA Technical Reports Server (NTRS)
Yang, Xianbin
2015-01-01
AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.
The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Y., E-mail: yjma@ciae.ac.cn; Cui, B.; Ma, R.
The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will bemore » installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.« less
A new framework for designing programmes of assessment
Van der Vleuten, C. P. M.; Schuwirth, L. W. T.
2009-01-01
Research on assessment in medical education has strongly focused on individual measurement instruments and their psychometric quality. Without detracting from the value of this research, such an approach is not sufficient to high quality assessment of competence as a whole. A programmatic approach is advocated which presupposes criteria for designing comprehensive assessment programmes and for assuring their quality. The paucity of research with relevance to programmatic assessment, and especially its development, prompted us to embark on a research project to develop design principles for programmes of assessment. We conducted focus group interviews to explore the experiences and views of nine assessment experts concerning good practices and new ideas about theoretical and practical issues in programmes of assessment. The discussion was analysed, mapping all aspects relevant for design onto a framework, which was iteratively adjusted to fit the data until saturation was reached. The overarching framework for designing programmes of assessment consists of six assessment programme dimensions: Goals, Programme in Action, Support, Documenting, Improving and Accounting. The model described in this paper can help to frame programmes of assessment; it not only provides a common language, but also a comprehensive picture of the dimensions to be covered when formulating design principles. It helps identifying areas concerning assessment in which ample research and development has been done. But, more importantly, it also helps to detect underserved areas. A guiding principle in design of assessment programmes is fitness for purpose. High quality assessment can only be defined in terms of its goals. PMID:19821042
A new framework for designing programmes of assessment.
Dijkstra, J; Van der Vleuten, C P M; Schuwirth, L W T
2010-08-01
Research on assessment in medical education has strongly focused on individual measurement instruments and their psychometric quality. Without detracting from the value of this research, such an approach is not sufficient to high quality assessment of competence as a whole. A programmatic approach is advocated which presupposes criteria for designing comprehensive assessment programmes and for assuring their quality. The paucity of research with relevance to programmatic assessment, and especially its development, prompted us to embark on a research project to develop design principles for programmes of assessment. We conducted focus group interviews to explore the experiences and views of nine assessment experts concerning good practices and new ideas about theoretical and practical issues in programmes of assessment. The discussion was analysed, mapping all aspects relevant for design onto a framework, which was iteratively adjusted to fit the data until saturation was reached. The overarching framework for designing programmes of assessment consists of six assessment programme dimensions: Goals, Programme in Action, Support, Documenting, Improving and Accounting. The model described in this paper can help to frame programmes of assessment; it not only provides a common language, but also a comprehensive picture of the dimensions to be covered when formulating design principles. It helps identifying areas concerning assessment in which ample research and development has been done. But, more importantly, it also helps to detect underserved areas. A guiding principle in design of assessment programmes is fitness for purpose. High quality assessment can only be defined in terms of its goals.
Automatisms in EMIR instrument to improve operation, safety and maintenance
NASA Astrophysics Data System (ADS)
Fernández Izquierdo, Patricia; Núñez Cagigal, Miguel; Barreto Rodríguez, Roberto; Martínez Rey, Noelia; Santana Tschudi, Samuel; Barreto Cabrera, Maria; Patrón Recio, Jesús; Garzón López, Francisco
2014-08-01
EMIR is the NIR imager and multiobject spectrograph being built as a common user instrument for the 10-m class GTC. Big cryogenic instruments demand a reliable design and a specific hardware and software to increase its safety and productivity. EMIR vacuum, cooling and heating systems are monitored and partially controlled by a Programmable Logic Controller (PLC) in industrial format with a touch screen. The PLC aids the instrument operator in the maintenance tasks recovering autonomously vacuum if required or proposing preventive maintenance actions. The PLC and its associated hardware improve EMIR safety having immediate reactions against eventual failure modes in the instrument or in external supplies, including hardware failures during the heating procedure or failure in the PLC itself. EMIR PLC provides detailed information periodically about status and alarms of vacuum and cooling components or external supplies.
Dutch digital breast cancer screening: implications for breast cancer care.
Timmers, Johanna M; den Heeten, Gerard J; Adang, Eddy M; Otten, Johannes D; Verbeek, André L; Broeders, Mireille J
2012-12-01
In comparison to other European population-based breast cancer screening programmes, the Dutch programme has a low referral rate, similar breast cancer detection and a high breast cancer mortality reduction. The referral rate in the Netherlands has increased over time and is expected to rise further, mainly following nationwide introduction of digital mammography, completed in 2010. This study explores the consequences of the introduction of digital mammography on the balance between referral rate, detection of breast cancer, diagnostic work-up and associated costs. Detailed information on diagnostic work-up (chart review) was obtained from referred women (n = 988) in 2000-06 (100% analogue mammography) and 2007 (75% digital mammography) in Nijmegen, the Netherlands. The average referral rate increased from 15 (2000-06) to 34 (2007) per 1000 women screened. The number of breast cancers detected increased from 5.5 to 7.8 per 1000 screens, whereas the positive predictive value fell from 37% to 23%. A sharp rise in diagnostic work-up procedures and total diagnostic costs was seen. On the other hand, costs of a single work-up slightly decreased, as less surgical biopsies were performed. Our study shows that a low referral rate in combination with the introduction of digital mammography affects the balance between referral rate and detection rate and can substantially influence breast cancer care and associated costs. Referral rates in the Netherlands are now more comparable to other countries. This effect is therefore of value in countries where implementation of digital breast cancer screening has just started or is still under discussion.
ERIC Educational Resources Information Center
Ryser, Gail R.; Campbell, Hilary L.; Miller, Brian K.
2010-01-01
The diagnostic criteria for attention deficit hyperactivity disorder have evolved over time with current versions of the "Diagnostic and Statistical Manual", (4th edition), text revision, ("DSM-IV-TR") suggesting that two constellations of symptoms may be present alone or in combination. The SCALES instrument for diagnosing attention deficit…
Analysis of Students' Error in Learning of Quadratic Equations
ERIC Educational Resources Information Center
Zakaria, Effandi; Ibrahim; Maat, Siti Mistima
2010-01-01
The purpose of the study was to determine the students' error in learning quadratic equation. The samples were 30 form three students from a secondary school in Jambi, Indonesia. Diagnostic test was used as the instrument of this study that included three components: factorization, completing the square and quadratic formula. Diagnostic interview…
[Instruments for quantitative methods of nursing research].
Vellone, E
2000-01-01
Instruments for quantitative nursing research are a mean to objectify and measure a variable or a phenomenon in the scientific research. There are direct instruments to measure concrete variables and indirect instruments to measure abstract concepts (Burns, Grove, 1997). Indirect instruments measure the attributes by which a concept is made of. Furthermore, there are instruments for physiologic variables (e.g. for the weight), observational instruments (Check-lists e Rating Scales), interviews, questionnaires, diaries and the scales (Check-lists, Rating Scales, Likert Scales, Semantic Differential Scales e Visual Anologue Scales). The choice to select an instrument or another one depends on the research question and design. Instruments research are very useful in research both to describe the variables and to see statistical significant relationships. Very carefully should be their use in the clinical practice for diagnostic assessment.
Programmable wide field spectrograph for earth observation
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Costes, Vincent; Hébert, Philippe-Jean
2017-11-01
In Earth Observation, Universe Observation and Planet Exploration, scientific return of the instruments must be optimized in future missions. Micro-Opto-Electro-Mechanical Systems (MOEMS) could be key components in future generation of space instruments. These devices are based on the mature micro-electronics technology and in addition to their compactness, scalability, and specific task customization, they could generate new functions not available with current technologies. French and European space agencies, the Centre National d'Etudes Spatiales (CNES) and the European Space Agency (ESA) have initiated several studies with LAM and TAS for listing the new functions associated with several types of MEMS, and developing new ideas of instruments.
Niesink, A; Trappenburg, J C A; de Weert-van Oene, G H; Lammers, J W J; Verheij, T J M; Schrijvers, A J P
2007-11-01
Chronic disease management for patients with chronic obstructive pulmonary disease (COPD) may improve quality, outcomes and access to care. To investigate effectiveness of chronic disease management programmes on the quality-of-life of people with COPD. Medline and Embase (1995-2005) were searched for relevant articles, and reference lists and abstracts were searched for controlled trials of chronic disease management programmes for patients with COPD. Quality-of-life was assessed as an outcome parameter. Two reviewers independently reviewed each paper for methodological quality and extracted the data. We found 10 randomized-controlled trials comparing chronic disease management with routine care. Patient populations, health-care professionals, intensity, and content of the intervention were heterogeneous. Different instruments were used to assess quality of life. Five out of 10 studies showed statistically significant positive outcomes on one or more domains of the quality of life instruments. Three studies, partly located in primary care, showed positive results. All chronic disease management projects for people with COPD involving primary care improved quality of life. In most of the studies, aspects of chronic disease management were applied to a limited extent. Quality of randomized-controlled trials was not optimal. More research is needed on chronic disease management programmes in patients with COPD across primary and secondary care.
Bolme, C A; Ramos, K J
2013-08-01
A line-imaging velocity interferometer was implemented on a single-stage light gas gun to probe the spatial heterogeneity of mechanical response, chemical reaction, and initiation of detonation in explosives. The instrument is described in detail, and then data are presented on several shock-compressed materials to demonstrate the instrument performance on both homogeneous and heterogeneous samples. The noise floor of this diagnostic was determined to be 0.24 rad with a shot on elastically compressed sapphire. The diagnostic was then applied to two heterogeneous plastic bonded explosives: 3,3(')-diaminoazoxyfurazan (DAAF) and PBX 9501, where significant spatial velocity heterogeneity was observed during the build up to detonation. In PBX 9501, the velocity heterogeneity was consistent with the explosive grain size, however in DAAF, we observed heterogeneity on a much larger length scale than the grain size that was similar to the imaging resolution of the instrument.
NASA Astrophysics Data System (ADS)
Bolme, C. A.; Ramos, K. J.
2013-08-01
A line-imaging velocity interferometer was implemented on a single-stage light gas gun to probe the spatial heterogeneity of mechanical response, chemical reaction, and initiation of detonation in explosives. The instrument is described in detail, and then data are presented on several shock-compressed materials to demonstrate the instrument performance on both homogeneous and heterogeneous samples. The noise floor of this diagnostic was determined to be 0.24 rad with a shot on elastically compressed sapphire. The diagnostic was then applied to two heterogeneous plastic bonded explosives: 3,3'-diaminoazoxyfurazan (DAAF) and PBX 9501, where significant spatial velocity heterogeneity was observed during the build up to detonation. In PBX 9501, the velocity heterogeneity was consistent with the explosive grain size, however in DAAF, we observed heterogeneity on a much larger length scale than the grain size that was similar to the imaging resolution of the instrument.
NASA Technical Reports Server (NTRS)
1985-01-01
Developments related to laser Doppler velocimetry are discussed, taking into account a three-component dual beam laser-Doppler-anemometer to be operated in large wind tunnels, a new optical system for three-dimensional laser-Doppler-anemometry using an argon-ion and a dye laser, and a two-component laser Doppler velocimeter by switching fringe orientation. Other topics studied are concerned with facilities, instrumentation, control, hot wire/thin film measurements, optical diagnostic techniques, signal and data processing, facilities and adaptive wall test sections, data acquisition and processing, ballistic instrument systems, dynamic testing and material deformation measurements, optical flow measurements, test techniques, force measurement systems, and holography. Attention is given to nonlinear calibration of integral wind tunnel balances, a microcomputer system for real time digitized image compression, and two phase flow diagnostics in propulsion systems.
Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.
Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L
2010-06-01
To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.
Mexico's conditional cash transfer programme increases cesarean section rates among the rural poor.
Barber, Sarah L
2010-08-01
Caesarean section rates are increasing in Mexico and Latin America. This study evaluates the impact of a large-scale, conditional cash transfer programme in Mexico on caesarean section rates. The programme provides cash transfers to participating low income, rural households in Mexico conditional on accepting health care and nutrition supplements. The primary analyses uses retrospective reports from 979 women in poor rural communities participating in an effectiveness study and randomly assigned to incorporation into the programme in 1998 or 1999 across seven Mexican states. Using multivariate and instrumental variable analyses, we estimate the impact of the programme on caesarean sections and predict the adjusted mean rates by clinical setting. Programme participation is measured by beneficiary status, programme months and cash transfers. More than two-thirds of poor rural women delivered in a health facility. Beneficiary status is associated with a 5.1 percentage point increase in caesarean rates; this impact increases to 7.5 percentage points for beneficiaries enrolled in the programme for >or=6 months before delivery. Beneficiaries had significantly higher caesarean delivery rates in social security facilities (24.0 compared with 5.6% among non-beneficiaries) and in other government facilities (19.3 compared with 9.5%). The Oportunidades conditional cash transfer programme is associated with higher caesarean section rates in social security and government health facilities. This effect appears to be driven by the increases in disposable income from the cash transfer. These findings are relevant to other countries implementing conditional cash transfer programmes and health care requirements.
Tolerancing fluorometers for in-vitro diagnostics
NASA Astrophysics Data System (ADS)
Heinz, Eric
2009-02-01
Anyone can make a fluorometer. All that is needed is a light source, a detector, some filters and maybe some lenses. For commercial clinical instruments, however, our customers demand stability, reliability, and reproducibility. If research instruments are like race cars, commercial instruments should be like trucks. This demands that our fluorometer designs be carefully toleranced. This paper will discuss causes of variation and drift, and ways to make fluorometers that are stable and reproducible.
Commissioning Instrument for the GTC
NASA Astrophysics Data System (ADS)
Cuevas, S.; Sánchez, B.; Bringas, V.; Espejo, C.; Flores, R.; Chapa, O.; Lara, G.; Chavolla, A.; Anguiano, G.; Arciniega, S.; Dorantes, A.; González, J. L.; Montoya, J. M.; Toral, R.; Hernández, H.; Nava, R.; Devaney, N.; Castro, J.; Cavaller-Marqués, L.
2005-12-01
During the GTC integration phase, the Commissioning Instrument (CI) will be a diagnostic tool for performance verification. The CI features four operation modes: imaging, pupil imaging, Curvature WFS, and high resolution Shack-Hartmann WFS. This instrument was built by the Instituto de Astronomía UNAM and the Centro de Ingeniería y Desarrollo Industrial (CIDESI) under GRANTECAN contract after a public bid. In this paper we made a general instrument overview and we show some of the performance final results obtained when the Factory Acceptance tests previous to its transport to La Palma.
Instrumentation for In-Flight SSME Rocket Engine Plume Spectroscopy
NASA Technical Reports Server (NTRS)
Madzsar, George C.; Bickford, Randall L.; Duncan, David B.
1994-01-01
This paper describes instrumentation that is under development for an in-flight demonstration of a plume spectroscopy system on the space shuttle main engine. The instrumentation consists of a nozzle mounted optical probe for observation of the plume, and a spectrometer for identification and quantification of plume content. This instrumentation, which is intended for use as a diagnostic tool to detect wear and incipient failure in rocket engines, will be validated by a hardware demonstration on the Technology Test Bed engine at the Marshall Space Flight Center.
2015-10-01
28 Magnetometer Applied Physics Model 1540-digital 3-axis fluxgate 5 Amplifiers Alligator Technologies USBPGF-S1 programmable instrumentation...Acoustic, Seismic, magnetic, footstep, vehicle, magnetometer , geophone, unattended ground sensor (UGS) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION
ERIC Educational Resources Information Center
Yetter, Carol J.
2009-01-01
This hearing aid primer is designed to define the differences among the three levels of hearing instrument technology: conventional analog circuit technology (most basic), digitally programmable/analog circuit technology (moderately advanced), and fully digital technology (most advanced). Both moderate and advanced technologies mean that hearing…
Glanemann, R; Reichmuth, K; am Zehnhoff-Dinnesen, A
2016-02-01
With the implementation of the UNHS, early educational services' existing concepts of early intervention have to be adapted to the situation and needs of families with a preverbal child who is deaf or hard of hearing. The Muenster Parental Programme (MPP), a module in early family-centered intervention, fulfils this requirement. We report feedback from participating parents regarding processes and outcomes of the MPP. The self-developed questionnaire was checked for its suitability as feedback instrument for measuring parental satisfaction with the MPP. 29 parents who participated in the MPP assessed the programme by using the standardised FBB and the self-developed questionnaire FB-MEP, which is specific to the MPP. Using the FBB, 96% of parents judged the MPP to be good or very good. With the FB-MEP, parents rated setting, contents and didactics as highly as they did using the FBB (r = 0.7, p < 0.01). In particular, parents judged both the contact and exchange with other affected parents, and the specific individual support for communicating with their child (including video feedback) as especially helpful. The results reflect parents' high level of satisfaction with the setting, content, didactics and individual benefit gained by their child and themselves from the MPP. The parents are aware of the efficacy of the MPP, which was shown in the controlled intervention study. The self-developed questionnaire FB-MEP was shown to be a suitable instrument for quality assurance measurements of the MPP.
Diagnosing Students' Understanding of the Nature of Models
ERIC Educational Resources Information Center
Gogolin, Sarah; Krüger, Dirk
2017-01-01
Students' understanding of models in science has been subject to a number of investigations. The instruments the researchers used are suitable for educational research but, due to their complexity, cannot be employed directly by teachers. This article presents forced choice (FC) tasks, which, assembled as a diagnostic instrument, are supposed to…
European commission research on stratospheric ozone depletion
NASA Astrophysics Data System (ADS)
Amanatidis, G. T.; Ott, H.
1995-02-01
The research policy of the European Commission (EC) on the stratospheric ozone depletion, which is implemented through the ENVIRONMENT Programme is described. The strategy of this stratospheric ozone research, which is developed to address the open scientific questions, requires a coordinated and balanced programme which is based on long term measurements, process studies at regional or global scale, laboratory studies, continuous and accurate measurements of ultraviolet (UV) radiation and development of instrumentation. These research activities, whenever necessary, take form of extensive and coordinated experiments (EASOE 1991/92, SESAME 1994-95), while the overall objective is to provide a firm scientific basis for future European Union (EU) policy actions in this area. Finally, priorities which have been identified for future research in the ENVIRONMENT and CLIMATE Programme (1994-1998) are also detailed.
Diagnosing Students' Understanding of the Nature of Models
NASA Astrophysics Data System (ADS)
Gogolin, Sarah; Krüger, Dirk
2017-10-01
Students' understanding of models in science has been subject to a number of investigations. The instruments the researchers used are suitable for educational research but, due to their complexity, cannot be employed directly by teachers. This article presents forced choice (FC) tasks, which, assembled as a diagnostic instrument, are supposed to measure students' understanding of the nature of models efficiently, while being sensitive enough to detect differences between individuals. In order to evaluate if the diagnostic instrument is suitable for its intended use, we propose an approach that complies with the demand to integrate students' responses to the tasks into the validation process. Evidence for validity was gathered based on relations to other variables and on students' response processes. Students' understanding of the nature of models was assessed using three methods: FC tasks, open-ended tasks and interviews ( N = 448). Furthermore, concurrent think-aloud protocols ( N = 30) were performed. The results suggest that the method and the age of the students have an effect on their understanding of the nature of models. A good understanding of the FC tasks as well as a convergence in the findings across the three methods was documented for grades eleven and twelve. This indicates that teachers can use the diagnostic instrument for an efficient and, at the same time, valid diagnosis for this group. Finally, the findings of this article may provide a possible explanation for alternative findings from previous studies as a result of specific methods that were used.
Recent Progress and Future Plans for Fusion Plasma Synthetic Diagnostics Platform
NASA Astrophysics Data System (ADS)
Shi, Lei; Kramer, Gerrit; Tang, William; Tobias, Benjamin; Valeo, Ernest; Churchill, Randy; Hausammann, Loic
2015-11-01
The Fusion Plasma Synthetic Diagnostics Platform (FPSDP) is a Python package developed at the Princeton Plasma Physics Laboratory. It is dedicated to providing an integrated programmable environment for applying a modern ensemble of synthetic diagnostics to the experimental validation of fusion plasma simulation codes. The FPSDP will allow physicists to directly compare key laboratory measurements to simulation results. This enables deeper understanding of experimental data, more realistic validation of simulation codes, quantitative assessment of existing diagnostics, and new capabilities for the design and optimization of future diagnostics. The Fusion Plasma Synthetic Diagnostics Platform now has data interfaces for the GTS and XGC-1 global particle-in-cell simulation codes with synthetic diagnostic modules including: (i) 2D and 3D Reflectometry; (ii) Beam Emission Spectroscopy; and (iii) 1D Electron Cyclotron Emission. Results will be reported on the delivery of interfaces for the global electromagnetic PIC code GTC, the extended MHD M3D-C1 code, and the electromagnetic hybrid NOVAK eigenmode code. Progress toward development of a more comprehensive 2D Electron Cyclotron Emission module will also be discussed. This work is supported by DOE contract #DEAC02-09CH11466.
Development of a portable non-contact optical diagnostic system for the detection of δ-HMX
NASA Astrophysics Data System (ADS)
Dale, Andrew J.; Wright, Mark W.; Hughes, Christopher T.; Bowden, Mike D.
2007-09-01
If a HMX-based explosive is subjected to an insult then there is a potential for the insulted β-HMX to undergo a phase change to the more sensitive δ form. AWE has an ongoing programme to develop a science-based model of the response of HMX-based explosives to potential insults. As part of this programme there is a need to identify whether δ-HMX has been formed, as this would subsequently affect the intrinsic safety properties of the formulation. δ-HMX, unlike the more stable β form, exhibits unusual optical properties for an explosive, as it acts as a frequency-doubling material. When illuminated by a high-energy laser pulse areas of the explosive charge that contain δ-HMX emit frequency doubled light. This non-linear optical phenomenon allows for a non-invasive diagnostic to be developed to study creation of the more sensitive δ phase within HMX based formulations. AWE has developed a portable diagnostic system based on this concept to investigate the behaviour of HMX-based explosives after low-speed impacts. The results of the commissioning trials are presented; using both an inert simulant, KDP, to align and prove the system and HMX samples from low-speed impact experiments. The results of these experiments are compared to initial calculations using the Hydrocode EDEN.
Diagnostic accuracy of imaging devices in glaucoma: A meta-analysis.
Fallon, Monica; Valero, Oliver; Pazos, Marta; Antón, Alfonso
Imaging devices such as the Heidelberg retinal tomograph-3 (HRT3), scanning laser polarimetry (GDx), and optical coherence tomography (OCT) play an important role in glaucoma diagnosis. A systematic search for evidence-based data was performed for prospective studies evaluating the diagnostic accuracy of HRT3, GDx, and OCT. The diagnostic odds ratio (DOR) was calculated. To compare the accuracy among instruments and parameters, a meta-analysis considering the hierarchical summary receiver-operating characteristic model was performed. The risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Studies in the context of screening programs were used for qualitative analysis. Eighty-six articles were included. The DOR values were 29.5 for OCT, 18.6 for GDx, and 13.9 for HRT. The heterogeneity analysis demonstrated statistically a significant influence of degree of damage and ethnicity. Studies analyzing patients with earlier glaucoma showed poorer results. The risk of bias was high for patient selection. Screening studies showed lower sensitivity values and similar specificity values when compared with those included in the meta-analysis. The classification capabilities of GDx, HRT, and OCT were high and similar across the 3 instruments. The highest estimated DOR was obtained with OCT. Diagnostic accuracy could be overestimated in studies including prediagnosed groups of subjects. Copyright © 2017 Elsevier Inc. All rights reserved.
Status of the design of the ITER ECE diagnostic
Taylor, G.; Austin, M. E.; Beno, J. H.; ...
2015-03-12
In this study, the baseline design for the ITER electron cyclotron emission (ECE) diagnostic has entered the detailed preliminary design phase. Two plasma views are planned, a radial view and an oblique view that is sensitive to distortions in the electron momentum distribution near the average thermal momentum. Both views provide high spatial resolution electron temperature profiles when the momentum distribution remains Maxwellian. The ECE diagnostic system consists of the front-end optics, including two 1000 K calibration sources, in equatorial port plug EP9, the 70-1000 GHz transmission system from the front-end to the diagnostics hall, and the ECE instrumentation inmore » the diagnostics hall. The baseline ECE instrumentation will include two Michelson interferometers that can simultaneously measure ordinary and extraordinary mode ECE from 70 to 1000 GHz, and two heterodyne radiometer systems, covering 122-230 GHz and 244-355 GHz. Significant design challenges include 1) developing highly-reliable 1000 K calibration sources and the associated shutters/mirrors, 2) providing compliant couplings between the front-end optics and the polarization splitter box that accommodate displacements of the vacuum vessel during plasma operations and bake out, 3) protecting components from damage due to stray ECH radiation and other intense millimeter wave emission and 4) providing the low-loss broadband transmission system.« less
Nishikiori, Nobuyuki; Van Weezenbeek, Catharina
2013-02-02
Despite the progress made in the past decade, tuberculosis (TB) control still faces significant challenges. In many countries with declining TB incidence, the disease tends to concentrate in vulnerable populations that often have limited access to health care. In light of the limitations of the current case-finding approach and the global urgency to improve case detection, active case-finding (ACF) has been suggested as an important complementary strategy to accelerate tuberculosis control especially among high-risk populations. The present exercise aims to develop a model that can be used for county-level project planning. A simple deterministic model was developed to calculate the number of estimated TB cases diagnosed and the associated costs of diagnosis. The model was designed to compare cost-effectiveness parameters, such as the cost per case detected, for different diagnostic algorithms when they are applied to different risk populations. The model was transformed into a web-based tool that can support national TB programmes and civil society partners in designing ACF activities. According to the model output, tuberculosis active case-finding can be a costly endeavor, depending on the target population and the diagnostic strategy. The analysis suggests the following: (1) Active case-finding activities are cost-effective only if the tuberculosis prevalence among the target population is high. (2) Extensive diagnostic methods (e.g. X-ray screening for the entire group, use of sputum culture or molecular diagnostics) can be applied only to very high-risk groups such as TB contacts, prisoners or people living with human immunodeficiency virus (HIV) infection. (3) Basic diagnostic approaches such as TB symptom screening are always applicable although the diagnostic yield is very limited. The cost-effectiveness parameter was sensitive to local diagnostic costs and the tuberculosis prevalence of target populations. The prioritization of appropriate target populations and careful selection of cost-effective diagnostic strategies are critical prerequisites for rational active case-finding activities. A decision to conduct such activities should be based on the setting-specific cost-effectiveness analysis and programmatic assessment. A web-based tool was developed and is available to support national tuberculosis programmes and partners in the formulation of cost-effective active case-finding activities at the national and subnational levels.
Lee, W R; Kim, H S; Park, M K; Lee, J H; Kim, K H
2012-09-01
The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.
Physical processes and diagnostics of gamma-ray burst emission
NASA Technical Reports Server (NTRS)
Harding, Alice K.
1992-01-01
With improved data from BATSE and other instruments, it is important to develop a range of diagnostic tools to link gamma-ray burst observations with theory. I will review some of the physical processes which may take place to form the spectrum of gamma-ray burst sources, assuming that the bursts originate on strongly magnetized neutron stars. The important diagnostics that these processes provide to probe the emission region and how they might be used to interpret observed spectra will also be discussed.
ERIC Educational Resources Information Center
Matson, Johnny L.; Mahan, Sara; Hess, Julie A.; Fodstad, Jill C.; Neal, Daniene
2010-01-01
Previous studies analyzed the reliability as well as sensitivity and specificity of the Autism Spectrum Disorder-Diagnostic for Children (ASD-DC). This study further examines the psychometric properties of the ASD-DC by assessing whether the ASD-DC has convergent validity against a psychometrically sound observational instrument for Autistic…
Diagnostic Group Differences in Parent and Teacher Ratings on the BRIEF and Conners' Scales
ERIC Educational Resources Information Center
Sullivan, Jeremy R.; Riccio, Cynthia A.
2007-01-01
Objective: Behavioral rating scales are common instruments used in evaluations of ADHD and executive function. It is important to explore how different diagnostic groups perform on these measures, as this information can be used to provide criterion-related validity evidence for the measures. Method: Data from 92 children and adolescents were used…
Diagnostic Appraisal of Grade 12 Students' Understanding of Reaction Kinetics
ERIC Educational Resources Information Center
Yan, Yaw Kai; Subramaniam, R.
2016-01-01
The study explored grade 12 students' understanding of reaction kinetics, a topic which has not been extensively explored in the chemistry education literature at this level. A 3-tier diagnostic instrument with 11 questions was developed--this format is of very recent origin and has been the subject of only a handful of studies. The findings…
ERIC Educational Resources Information Center
Oosterling, Iris; Rommelse, Nanda; De Jonge, Maretha; Van Der Gaag, Rutger Jan; Swinkels, Sophie; Roos, Sascha; Visser, Janne; Buitelaar, Jan
2010-01-01
Background: The Social Communication Questionnaire (SCQ) is a screening instrument with established validity against the Autism Diagnostic Interview-Revised (ADI-R) in children aged 4 years and older. Indices of diagnostic accuracy have been shown to be strong in school-aged samples; however, relatively little is known about the performance of the…
R and D program for core instrumentation improvements devoted for French sodium fast reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeannot, J. P.; Rodriguez, G.; Jammes, C.
2011-07-01
Under the framework of French R and D studies for Generation IV reactors and more specifically for sodium-cooled fast reactors (SFR); the CEA, EDF and AREVA have launched a joint coordinated research programme. This paper deals with the R and D sets out to achieve better inspection, maintenance, availability and decommissioning. In particular the instrumentation requirements for core monitoring and detection in the case of accidental events. Requirements mainly involve diversifying the means of protection and improving instrumentation performance in terms of responsiveness and sensitivity. Operation feedback from the Phenix and Superphenix prototype reactors and studies, carried out within themore » scope of the EFR projects, has been used to define the needs for instrumentation enhancement. (authors)« less
NASA Astrophysics Data System (ADS)
Coleman, L. W.
1985-01-01
Progress in laser fusion research has increased the need for detail and precision in the diagnosis of experiments. This has spawned the development and use of sophisticated sub-nanosecond resolution diagnostic systems. These systems typically use ultrafast X-ray or optical streak cameras in combination with spatially imaging or spectrally dispersing elements. These instruments provide high resolution data essential for understanding the processes occurring in the interaction of high intensity laser light with targets. Several of these types of instruments and their capabilities will be discussed. The utilization of these kinds of diagnostics systems on the nearly completed 100 kJ Nova laser facility will be described.
The matter in extreme conditions instrument at the Linac Coherent Light Source
Nagler, Bob; Arnold, Brice; Bouchard, Gary; ...
2015-04-21
The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented.
Vestibular Function Measurement Devices
Miles, Richard D.; Zapala, David A.
2015-01-01
Vestibular function laboratories utilize a multitude of diagnostic instruments to evaluate a dizzy patient. Caloric irrigators, oculomotor stimuli, and rotational chairs produce a stimulus whose accuracy is required for the patient response to be accurate. Careful attention to everything from cleanliness of equipment to threshold adjustments determine on a daily basis if patient data are going to be correct and useful. Instrumentation specifications that change with time such as speed and temperature must periodically be checked using calibrated instruments. PMID:27516710
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vacas-Jacques, Paulino; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts 02114; Linnes, Jacqueline
Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second,more » the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.« less
Advanced Electronic Systems. Curriculum Guide for Technology Education.
ERIC Educational Resources Information Center
Patrick, Dale R.
This curriculum for a 1-semester or 1-year course in electronics is designed to take students from basic through advanced electronic systems. It covers several electronic areas, such as digital electronics, communication electronics, industrial process control, instrumentation, programmable controllers, and robotics. The guide contains…
NASA Astrophysics Data System (ADS)
Zimmermann, Judith; von Davier, Alina A.; Buhmann, Joachim M.; Heinimann, Hans R.
2018-01-01
Graduate admission has become a critical process in tertiary education, whereby selecting valid admissions instruments is key. This study assessed the validity of Graduate Record Examination (GRE) General Test scores for admission to Master's programmes at a technical university in Europe. We investigated the indicative value of GRE scores for the Master's programme grade point average (GGPA) with and without the addition of the undergraduate GPA (UGPA) and the TOEFL score, and of GRE scores for study completion and Master's thesis performance. GRE scores explained 20% of the variation in the GGPA, while additional 7% were explained by the TOEFL score and 3% by the UGPA. Contrary to common belief, the GRE quantitative reasoning score showed only little explanatory power. GRE scores were also weakly related to study progress but not to thesis performance. Nevertheless, GRE and TOEFL scores were found to be sensible admissions instruments. Rigorous methodology was used to obtain highly reliable results.
NASA Astrophysics Data System (ADS)
Tamai, Roberto; Cirasuolo, Michele; González, Juan Carlos; Koehler, Bertrand; Tuti, Mauro
2016-07-01
ESO is now fully engaged in building the European Extremely Large Telescope (E-ELT), a 40-m class optical nearinfrared telescope to be installed on top of Cerro Armazones, Chile and become operational around 2025. The Programme was formally approved by ESO Council back in 2012. However the required funding level for starting construction was actually reached in 2014, leading to a Green Light to start large construction contracts in December of that year. Since then, the programme has entered a very busy phase leading to the signature of the first major industrial contracts as well as the agreements with scientific institutes in ESO Member States to design and built the first suite of science instruments. This paper summarizes the current status of the E-ELT Programme and presents some aspects related to scientific objectives, managerial organization, programmatic aspects and system engineering approach. It also outlines the procurement strategies put in place to achieve the goal of the Programme: building the 'world's biggest eye on the sky' within the next decade.
[Financial incentives for quality improvement].
Belicza, Eva; Evetovits, Tamás
2010-05-01
Policy makers and payers of health care services devote increasing attention to improve quality of services by incentivising health care providers. These--so called--pay for performance (P4P) programmes have so far been introduced in few countries only and evidence on their effectiveness is still scarce. Therefore we do not know yet which instruments of these programmes are most effective and efficient in improving quality. The P4P systems implemented so far in primary care and in integrated delivery systems use indicators for measurement of performance and the basis for rewards. These indicators are mostly process indicators, but there are some outcome indicators as well. The desired quality improvement effects are most likely to be achieved with programmes that provide seizable financial rewards and cover the extra cost of quality improvement efforts as well. Administration of the programme has to be fully transparent and clear to all involved. It has to be based on scientific evidence and supported with sufficient dedicated funding. Conducting pilot studies is a precondition for large scale implementation.
Debris and shrapnel assessments for National Ignition Facility targets and diagnostics
NASA Astrophysics Data System (ADS)
Masters, N. D.; Fisher, A.; Kalantar, D.; Stölken, J.; Smith, C.; Vignes, R.; Burns, S.; Doeppner, T.; Kritcher, A.; Park, H.-S.
2016-05-01
High-energy laser experiments at the National Ignition Facility (NIF) can create debris and shrapnel capable of damaging laser optics and diagnostic instruments. The size, composition and location of target components and sacrificial shielding (e.g., disposable debris shields, or diagnostic filters) and the protection they provide is constrained by many factors, including: chamber and diagnostic geometries, experimental goals and material considerations. An assessment of the generation, nature and velocity of shrapnel and debris and their potential threats is necessary prior to fielding targets or diagnostics. These assessments may influence target and shielding design, filter configurations and diagnostic selection. This paper will outline the approach used to manage the debris and shrapnel risk associated with NIF targets and diagnostics and present some aspects of two such cases: the Material Strength Rayleigh- Taylor campaign and the Mono Angle Crystal Spectrometer (MACS).
The Ocean Surface Topography JASON-CS/SENTINEL-6 Mission
NASA Astrophysics Data System (ADS)
Cullen, R.; Francis, R.
2014-12-01
The Jason-CS/Sentinel-6 programme will consist of 2 spacecraft and will be the latest in a series of ocean surface topography missions that will span nearly three decades. They follow the altimeters on-board TOPEX/Poseidon through to Jason-3 (expected March 2015). Jason-CS will continue to fulfil objectives of the reference series whilst introducing a major enhancement in capability providing the operational and science oceanographic community with the state of the art in terms of platform, measurement instrumentation design thus securing optimal operational and science data return. The programme is a part of the EC Copernicus initiative, whose objective is to support Europe's goals regarding sustainable development and global governance of the environment by providing timely and quality data, information, services and knowledge. The programme brings together: ESA for development, procurement & early orbit activities; EUMETSAT for mission management, ground segment, flight ops, contributing funding of the 1st satellite and participation in funding for the 2nd satellite; NOAA for US payload instruments, launcher, ground stations & operations; NASA for developing the US payload, launcher procurement and funding US science; EU for funding the operations and participation in funding (with EUMETSAT) for the 2nd satellite; CNES for mission expertise and provision of POD. The consortium plan to procure 2 satellites with the 1st planned for launch readiness in the 1st half of 2020 with the 2nd satellite 5 years later. The first major commitment to funding was given by the ESA member states that approved the programme in June 2014 and in addition the European Union funding is also secure. The design will be based on a platform derived from CryoSat-2 but adjusted to the specific requirements of the higher orbit. The principle payload instrument is a high precision Ku/C band radar altimeter with retrieval of geophysical parameters (surface elevation, wind speed and SWH) from the altimeter data require supporting measurements: a DORIS receiver for POD; The Climate Quality Advanced Microwave Radiometer (AMR-C) provided by JPL for high stability path delay correction. Orbit tracking data are also provided by GPS & LRA. An additional US GPS receiver, GNSS-RO, will be dedicated to radio-occultation measurements.
Often Asked but Rarely Answered: Can Asians Meet DSM-5/ICD-10 Autism Spectrum Disorder Criteria?
Kim, So Hyun; Koh, Yun-Joo; Lim, Eun-Chung; Kim, Soo-Jeong; Leventhal, Bennett L.
2016-01-01
Abstract Objectives: To evaluate whether Asian (Korean children) populations can be validly diagnosed with autism spectrum disorder (ASD) using Western-based diagnostic instruments and criteria based on Diagnostic and Statistical Manual on Mental Disorders, 5th edition (DSM-5). Methods: Participants included an epidemiologically ascertained 7–14-year-old (N = 292) South Korean cohort from a larger prevalence study (N = 55,266). Main outcomes were based on Western-based diagnostic methods for Korean children using gold standard instruments, Autism Diagnostic Interview-Revised, and Autism Diagnostic Observation Schedule. Factor analysis and ANOVAs were performed to examine factor structure of autism symptoms and identify phenotypic differences between Korean children with ASD and non-ASD diagnoses. Results: Using Western-based diagnostic methods, Korean children with ASD were successfully identified with moderate-to-high diagnostic validity (sensitivities/specificities ranging 64%–93%), strong internal consistency, and convergent/concurrent validity. The patterns of autism phenotypes in a Korean population were similar to those observed in a Western population with two symptom domains (social communication and restricted and repetitive behavior factors). Statistically significant differences in the use of socially acceptable communicative behaviors (e.g., direct gaze, range of facial expressions) emerged between ASD versus non-ASD cases (mostly p < 0.001), ensuring that these can be a similarly valid part of the ASD phenotype in both Asian and Western populations. Conclusions: Despite myths, biases, and stereotypes about Asian social behavior, Asians (at least Korean children) typically use elements of reciprocal social interactions similar to those in the West. Therefore, standardized diagnostic methods widely used for ASD in Western culture can be validly used as part of the assessment process and research with Koreans and, possibly, other Asians. PMID:27315155
Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B
2010-01-01
The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to the clinical audit programme and the IAEA clinical audit protocol.
Chadha, Sarabjit; Nagaraja, Sharath Burugina; Prasad, Banaru Muralidhara; Kelamane, Santosha; Satyanarayana, Srinath; Sachdeva, Kuldeep Singh
2016-01-01
India is a high TB burden country. The preferred first line diagnostic tool under National TB Programme is sputum smear microscopy through binocular microscopes (BMs) from 13,000 designated microscopy centres across the country. The programme had devised innovative strategy for maintenance of BMs. A study was conducted to look into the operational feasibility of an external agency to provide maintenance services for BMs engaged through newer strategy. A cross-sectional study was conducted in the states of Uttar Pradesh, Bihar and Rajasthan during 2010-2013. A total of 9314 BMs were serviced during the period 2011-2013, of which 1104 (11.8%) had major repairs, 2204 (23.6%) had minor repairs, 1054 (11.3%) were provided emergency breakdown services and 223 (2.4%) were condemned. The bold initiative and newer strategy of the programme to engage agencies for BMs maintenance services is worthwhile and should be continued and could be considered for replication across the country. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
Fundamentals of materials, techniques and instrumentation for OSL and FNTD dosimetry
NASA Astrophysics Data System (ADS)
Akselrod, M. S.
2013-02-01
The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al2O3:C as a material of choice for many dosimetric applications including fiberoptic OSL/RL sensors with diameters as small as 300 μm. A new RL/OSL fiberoptic system has a high potential for in vivo and in vitro dosimetry in both radiation therapy and diagnostic mammography. Different aspects of instrumentation, data processing algorithms, post-irradiation and real-time measurements are described. The next technological breakthrough was done with Fluorescent Nuclear Track detectors (FNTD) that has some important advantages in measuring fast neutron and high energy heavy charge particles that became the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology were engineered and successfully demonstrated for occupational and accident dosimetry, for medical dosimetry and radiobiological research.
Alphus D. Wilson
2012-01-01
The rapid development of new electronic technologies and instruments, utilized to perform many current clinical operations in the biomedical field, is changing the way medical health care is delivered to patients. The majority of test results from laboratory analyses, performed with these analytical instruments often prior to clinical examinations, are frequently used...
ERIC Educational Resources Information Center
Pence, Brian Wells; Miller, William C.; Gaynes, Bradley N.
2009-01-01
Prevalence and validation studies rely on imperfect reference standard (RS) diagnostic instruments that can bias prevalence and test characteristic estimates. The authors illustrate 2 methods to account for RS misclassification. Latent class analysis (LCA) combines information from multiple imperfect measures of an unmeasurable latent condition to…
Soft X-ray astronomy using grazing incidence optics
NASA Technical Reports Server (NTRS)
Davis, John M.
1989-01-01
The instrumental background of X-ray astronomy with an emphasis on high resolution imagery is outlined. Optical and system performance, in terms of resolution, are compared and methods for improving the latter in finite length instruments described. The method of analysis of broadband images to obtain diagnostic information is described and is applied to the analysis of coronal structures.
Walker Readiness Test for Disadvantaged Pre-School Children; Forms A and B.
ERIC Educational Resources Information Center
Walker, Wanda
This instrument assesses readiness for school in preschool disadvantaged children. Two forms, A and B, are available and it is recommended that one be used as a diagnostic pretest and the other as a progress measure. The test is an individually administered, non-verbal, untimed, but paced instrument. The child responds to questions, given in…
The development of a clinical outcomes survey research application: Assessment CenterSM
Rothrock, Nan E.; Hanrahan, Rachel T.; Jansky, Liz J.; Harniss, Mark; Riley, William
2013-01-01
Introduction The National Institutes of Health sponsored Patient-Reported Outcome Measurement Information System (PROMIS) aimed to create item banks and computerized adaptive tests (CATs) across multiple domains for individuals with a range of chronic diseases. Purpose Web-based software was created to enable a researcher to create study-specific Websites that could administer PROMIS CATs and other instruments to research participants or clinical samples. This paper outlines the process used to develop a user-friendly, free, Web-based resource (Assessment CenterSM) for storage, retrieval, organization, sharing, and administration of patient-reported outcomes (PRO) instruments. Methods Joint Application Design (JAD) sessions were conducted with representatives from numerous institutions in order to supply a general wish list of features. Use Cases were then written to ensure that end user expectations matched programmer specifications. Program development included daily programmer “scrum” sessions, weekly Usability Acceptability Testing (UAT) and continuous Quality Assurance (QA) activities pre- and post-release. Results Assessment Center includes features that promote instrument development including item histories, data management, and storage of statistical analysis results. Conclusions This case study of software development highlights the collection and incorporation of user input throughout the development process. Potential future applications of Assessment Center in clinical research are discussed. PMID:20306332
Efficient optical cloud removal technique for earth observation based on MOEMs device
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Noell, Wilfried
2017-11-01
In Earth Observation instruments, observation of scenes including bright sources leads to an important degradation of the recorded signal. We propose a new concept to remove dynamically the bright sources and then obtain a field of view with an optically enhanced Signal-to-Noise Ratio (SNR). Micro-Opto-Electro-Mechanical Systems (MOEMS) could be key components in future generation of space instruments. MOEMS-based programmable slit masks will permit the straylight control in future Earth Observation instruments. Experimental demonstration of this concept has been conducted on a dedicated bench. This successful first demonstration shows the high potential of this new concept in future spectro-imager for Earth Observation.
Instrumentation and control of harmonic oscillators via a single-board microprocessor-FPGA device.
Picone, Rico A R; Davis, Solomon; Devine, Cameron; Garbini, Joseph L; Sidles, John A
2017-04-01
We report the development of an instrumentation and control system instantiated on a microprocessor-field programmable gate array (FPGA) device for a harmonic oscillator comprising a portion of a magnetic resonance force microscope. The specific advantages of the system are that it minimizes computation, increases maintainability, and reduces the technical barrier required to enter the experimental field of magnetic resonance force microscopy. Heterodyne digital control and measurement yields computational advantages. A single microprocessor-FPGA device improves system maintainability by using a single programming language. The system presented requires significantly less technical expertise to instantiate than the instrumentation of previous systems, yet integrity of performance is retained and demonstrated with experimental data.
Instrumentation and control of harmonic oscillators via a single-board microprocessor-FPGA device
NASA Astrophysics Data System (ADS)
Picone, Rico A. R.; Davis, Solomon; Devine, Cameron; Garbini, Joseph L.; Sidles, John A.
2017-04-01
We report the development of an instrumentation and control system instantiated on a microprocessor-field programmable gate array (FPGA) device for a harmonic oscillator comprising a portion of a magnetic resonance force microscope. The specific advantages of the system are that it minimizes computation, increases maintainability, and reduces the technical barrier required to enter the experimental field of magnetic resonance force microscopy. Heterodyne digital control and measurement yields computational advantages. A single microprocessor-FPGA device improves system maintainability by using a single programming language. The system presented requires significantly less technical expertise to instantiate than the instrumentation of previous systems, yet integrity of performance is retained and demonstrated with experimental data.
Optical filters for the Multispectral Instrument (MSI) on Sentinel-2
NASA Astrophysics Data System (ADS)
Merschdorf, M.; Camus, F.; Kirschner, V.
2017-11-01
Multi-spectral optical filters are essential parts of spaceborne optical imagers such as the Multispectral Instrument (MSI) for the Sentinel-2 satellite in the framework of ESA's GMES programme for earth observation. In this development, Jena-Optronik is responsible for the design, manufacturing and test of the spectral filter assemblies. They are the key elements that define the spectral quality of the instrument. Besides the challenging spectral requirements straylight aspects are of crucial importance due to the close neighbourhood of the filter elements to the detector. Results will be presented of the extensive analyses and measurements that have been performed on component and assembly level to ensure the optical performance.
ALADIN: the first european lidar in space
NASA Astrophysics Data System (ADS)
Morançais, Didier; Fabre, Frédéric; Schillinger, Marc; Barthès, Jean-Claude; Endemann, Martin; Culoma, Alain; Durand, Yannig
2017-11-01
The Atmospheric LAser Doppler INstrument (ALADIN) is the payload of the ESA's ADMAEOLUS mission, which aims at measuring wind profiles as required by the climatology and meteorology users. ALADIN belongs to a new class of Earth Observation payloads and will be the first European Lidar in space. The instrument comprises a diode-pumped high energy Nd:YAG laser and a direct detection receiver operating on aerosol and molecular backscatter signals in parallel. In addition to the Proto- Flight Model (PFM)., two instrument models are developed: a Pre-development Model (PDM) and an Opto-Structure-Thermal Model (OSTM). The flight instrument design and the industrial team has been finalised and the major equipment are now under development. This paper describes the instrument design and performance as well as the development and verification approach. The main results obtained during the PDM programme are also reported. The ALADIN instrument is developed under prime contractorship from EADS Astrium SAS with a consortium of thirty European companies.
Could clinical audit improve the diagnosis of pulmonary tuberculosis in Cuba, Peru and Bolivia?
Siddiqi, Kamran; Volz, Anna; Armas, L; Otero, L; Ugaz, R; Ochoa, E; Gotuzzo, E; Torrico, F; Newell, James N; Walley, J; Robinson, Mike; Dieltiens, G; Van der Stuyft, P
2008-04-01
To assess the effectiveness of clinical audit in improving the quality of diagnostic care provided to patients suspected of tuberculosis; and to understand the contextual factors which impede or facilitate its success. Twenty-six health centres in Cuba, Peru and Bolivia were recruited. Clinical audit was introduced to improve the diagnostic care for patients attending with suspected TB. Standards were based on the WHO and TB programme guidelines relating to the appropriate use of microscopy, culture and radiological investigations. At least two audit cycles were completed over 2 years. Improvement was determined by comparing the performance between two six-month periods pre- and post-intervention. Qualitative methods were used to ascertain facilitating and limiting contextual factors influencing change among healthcare professionals' clinical behaviour after the introduction of clinical audit. We found a significant improvement in 11 of 13 criteria in Cuba, in 2 of 6 criteria in Bolivia and in 2 of 5 criteria in Peru. Twelve out of 24 of the audit criteria in all three countries reached the agreed standards. Barriers to quality improvement included conflicting objectives for clinicians and TB programmes, poor coordination within the health system and patients' attitudes towards illness. Clinical audit may drive improvements in the quality of clinical care in resource-poor settings. It is likely to be more effective if integrated within and supported by the local TB programmes. We recommend developing and evaluating an integrated model of quality improvement including clinical audit.
ERIC Educational Resources Information Center
Badawi, Ramsey D.
2001-01-01
Describes the use of nuclear medicine techniques in diagnosis and therapy. Describes instrumentation in diagnostic nuclear medicine and predicts future trends in nuclear medicine imaging technology. (Author/MM)
ERIC Educational Resources Information Center
Physics Education, 1984
1984-01-01
Describes (1) use of VELA (a stand-alone programmable instrument); (2) forced harmonic motion of galvanometers; (3) holographic interferometry and measurement of small angular displacement; and (4) an analogy useful on teaching capacitors at A-level. Also describes a comparison of fuses and circuit breakers using a microcomputer as a storage…
Documenting Collections: Cornerstones for More History of Science in Museums
ERIC Educational Resources Information Center
Lourenço, Marta C.; Gessner, Samuel
2014-01-01
Historians of science have recently become increasingly involved with collections and scientific instruments. This creates opportunities for a more significant role of history in museums of science, as well as more meaningful and contextualized exhibitions and educational programmes. However, complementing the mainstream focus on universal…
Batman flies: a compact spectro-imager for space observation
NASA Astrophysics Data System (ADS)
Zamkotsian, Frederic; Ilbert, Olivier; Zoubian, Julien; Delsanti, Audrey; Boissier, Samuel; Lancon, Ariane
2017-11-01
Multi-object spectroscopy (MOS) is a key technique for large field of view surveys. MOEMS programmable slit masks could be next-generation devices for selecting objects in future infrared astronomical instrumentation for space telescopes. MOS is used extensively to investigate astronomical objects by optimizing the Signal-to-Noise Ratio (SNR): high precision spectra are obtained and the problem of spectral confusion and background level occurring in slitless spectroscopy is cancelled. Fainter limiting fluxes are reached and the scientific return is maximized both in cosmology and in legacy science. Major telescopes around the world are equipped with MOS in order to simultaneously record several hundred spectra in a single observation run. Next generation MOS for space like the Near Infrared Multi-Object Spectrograph (NIRSpec) for the James Webb Space Telescope (JWST) require a programmable multi-slit mask. Conventional masks or complex fiber-optics-based mechanisms are not attractive for space. The programmable multi-slit mask requires remote control of the multislit configuration in real time. During the early-phase studies of the European Space Agency (ESA) EUCLID mission, a MOS instrument based on a MOEMS device has been assessed. Due to complexity and cost reasons, slitless spectroscopy was chosen for EUCLID, despite a much higher efficiency with slit spectroscopy. A promising possible solution is the use of MOEMS devices such as micromirror arrays (MMA) [1,2,3] or micro-shutter arrays (MSA) [4]. MMAs are designed for generating reflecting slits, while MSAs generate transmissive slits. In Europe an effort is currently under way to develop single-crystalline silicon micromirror arrays for future generation infrared multi-object spectroscopy (collaboration LAM / EPFL-CSEM) [5,6]. By placing the programmable slit mask in the focal plane of the telescope, the light from selected objects is directed toward the spectrograph, while the light from other objects and from the sky background is blocked. To get more than 2 millions independent micromirrors, the only available component is a Digital Micromirror Device (DMD) chip from Texas Instruments (TI) that features 2048 x 1080 mirrors and a 13.68μm pixel pitch. DMDs have been tested in space environment (-40°C, vacuum, radiations) by LAM and no showstopper has been revealed [7]. We are presenting in this paper a DMD-based spectrograph called BATMAN, including two arms, one spectroscopic channel and one imaging channel. This instrument is designed for getting breakthrough results in several science cases, from high-z galaxies to nearby galaxies and Trans-Neptunian Objects of Kuiper Belt.
2013-01-01
Background Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. Methods A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55–74 years, and (c) biennial faecal immunochemical tests (FIT) at 55–74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55–64 years) and staggered age-based roll-out across the 55–74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55–74). Results FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381–1,053 with FSIG-based, and 967–1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. Conclusions While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning. PMID:23510135
Mphwatiwa, Treza; Witek-McManus, Stefan; Mtali, Austin; Okello, George; Nguluwe, Paul; Chatsika, Hard; Roschnik, Natalie; Halliday, Katherine E; Brooker, Simon J; Mathanga, Don P
2017-08-07
Training teachers to diagnose uncomplicated malaria using malaria rapid diagnostic tests and treat with artemisinin-based combination therapy has the potential to improve the access of primary school children (6-14 years) to prompt and efficient treatment for malaria, but little is known about the acceptability of such an intervention. This qualitative study explored experiences and perceptions of users and implementers of a programme of school-based malaria case management via a first-aid kit-the Learner Treatment Kit (LTK)-implemented as part of a cluster-randomized controlled trial in Zomba district, Malawi. From 29 primary schools where teachers were trained to test and treat school children for malaria using the LTK, six schools were purposively selected on the basis of relative intervention usage (low, medium or high); school size and geographical location. In total eight focus group discussions were held with school children, parents and guardians, and teachers; and 20 in-depth interviews were conducted with key stakeholders at the school, district and national levels. Interviews were recorded, transcribed, and analysed using a thematic analysis approach. The LTK was widely perceived by respondents to be a worthwhile intervention, with the opinion that trained teachers were trusted providers of malaria testing and treatment to school children. Benefits of the programme included a perception of improved access to malaria treatment for school children; decreased school absenteeism; and that the programme supported broader national health and education policies. Potential barriers to successful implementation expressed included increased teacher workloads, a feeling of inadequate supervision from health workers, lack of incentives and concerns for the sustainability of the programme regarding the supply of drugs and commodities. Training teachers to test for and treat uncomplicated malaria in schools was well received by both users and implementers alike, and was perceived by the majority of stakeholders to be a valuable programme. Factors raised as critical to the success of such a programme included ensuring an effective supervisory system, a reliable supply chain, and the training of greater numbers of teachers per school to manage high consultation numbers, especially during the peak malaria transmission season.
The Matter in Extreme Conditions instrument at the Linac Coherent Light Source
Nagler, Bob; Arnold, Brice; Bouchard, Gary; Boyce, Richard F.; Boyce, Richard M.; Callen, Alice; Campell, Marc; Curiel, Ruben; Galtier, Eric; Garofoli, Justin; Granados, Eduardo; Hastings, Jerry; Hays, Greg; Heimann, Philip; Lee, Richard W.; Milathianaki, Despina; Plummer, Lori; Schropp, Andreas; Wallace, Alex; Welch, Marc; White, William; Xing, Zhou; Yin, Jing; Young, James; Zastrau, Ulf; Lee, Hae Ja
2015-01-01
The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented. PMID:25931063
NASA Technical Reports Server (NTRS)
1992-01-01
The GENETI-SCANNER, newest product of Perceptive Scientific Instruments, Inc. (PSI), rapidly scans slides, locates, digitizes, measures and classifies specific objects and events in research and diagnostic applications. Founded by former NASA employees, PSI's primary product line is based on NASA image processing technology. The instruments karyotype - a process employed in analysis and classification of chromosomes - using a video camera mounted on a microscope. Images are digitized, enabling chromosome image enhancement. The system enables karyotyping to be done significantly faster, increasing productivity and lowering costs. Product is no longer being manufactured.
ERIC Educational Resources Information Center
Akarsu, Bayram
2011-01-01
In present paper, we propose a new diagnostic test to measure students' conceptual knowledge of principles of modern physics topics. Over few decades since born of physics education research (PER), many diagnostic instruments that measure students' conceptual understanding of various topics in physics, the earliest tests developed in PER are Force…
ERIC Educational Resources Information Center
Lai, Kelly Y. C.; Leung, Patrick W. L.; Mo, Flora Y. M.; Lee, Marshall M. C.; Shea, Caroline K. S.; Chan, Grace F. C.; Che, Kiti K. I.; Luk, Ernest S. L.; Mak, Arthur D. P.; Warrington, Richard; Skuse, David
2015-01-01
Autism spectrum disorder (ASD) is a disorder with high levels of co-morbidities. The Developmental, Dimensional and Diagnostic Interview (3Di) is a relatively new instrument designed to provide dimensional as well as categorical assessment of autistic behaviours among children with normal intelligence. Its sound psychometric properties and…
ERIC Educational Resources Information Center
Nyachwaya, James M.; Mohamed, Abdi-Rizak; Roehrig, Gillian H.; Wood, Nathan B.; Kern, Anne L.; Schneider, Jamie L.
2011-01-01
Many studies in the chemical education literature report students' alternative conceptions in chemistry and the difficulty they present for future learning. In this paper, we review existing diagnostic tools used to uncover students' alternative conceptions in chemistry and suggest that there are two fundamental issues with such instruments,…
View of the Challenger's payload bay and the Plasma Diagnostic package
NASA Technical Reports Server (NTRS)
1985-01-01
The solar optical universal polarimeter (SOUP) experiment is visible among the cluster of Spacelab 2 hardware in the cargo bay of the Shuttle Challenger. Various components of the instrument positioning system (IPS) are conspicuous at the center of the frame. The Plasma Diagnostic package (PDP) is seen attached to the remote manipulator system (RMS) above the open payload bay.
High Pressure Particulate Physics Facility
2011-03-26
controlled loading conditions, nanosecond time resolution diagnostics are required. Therefore, state of the art diagnostic tools such as Velocity...front end plate. The Data Acquisition System (DAS) is based on the state of the art National Instruments PXI system. The architecture provides...obtained by copper wire. In the future x-ray cinematography , line VISAR and time indexed spectroscopy are planned. SECTION III SUMMARY We are
NASA Technical Reports Server (NTRS)
Djuth, Frank T.; Elder, John H.; Williams, Kenneth L.
1996-01-01
This research program focused on the construction of several key radio wave diagnostics in support of the HF Active Auroral Ionospheric Research Program (HAARP). Project activities led to the design, development, and fabrication of a variety of hardware units and to the development of several menu-driven software packages for data acquisition and analysis. The principal instrumentation includes an HF (28 MHz) radar system, a VHF (50 MHz) radar system, and a high-speed radar processor consisting of three separable processing units. The processor system supports the HF and VHF radars and is capable of acquiring very detailed data with large incoherent scatter radars. In addition, a tunable HF receiver system having high dynamic range was developed primarily for measurements of stimulated electromagnetic emissions (SEE). A separate processor unit was constructed for the SEE receiver. Finally, a large amount of support instrumentation was developed to accommodate complex field experiments. Overall, the HAARP diagnostics are powerful tools for studying diverse ionospheric modification phenomena. They are also flexible enough to support a host of other missions beyond the scope of HAARP. Many new research programs have been initiated by applying the HAARP diagnostics to studies of natural atmospheric processes.
Identification student’s misconception of heat and temperature using three-tier diagnostic test
NASA Astrophysics Data System (ADS)
Suliyanah; Putri, H. N. P. A.; Rohmawati, L.
2018-03-01
The objective of this research is to develop a Three-Tier Diagnostic Test (TTDT) to identify the student's misconception of heat and temperature. Stages of development include: analysis, planning, design, development, evaluation and revise. The results of this study show that (1) the quality of the three-tier type diagnostic test instrument developed has been expressed well with the following details: (a) Internal validity of 88.19% belonging to the valid category. (b) External validity of empirical construct validity test using Pearson Product Moment obtained 0.43 is classified and result of empirical construct validity test obtained false positives 6.1% and false negatives 5.9% then the instrument was valid. (c) Test reliability by using Cronbach’s Alpha of 0.98 which means acceptable. (d) The 80% difficulty level test is quite difficult. (2) Student misconceptions on the temperature of heat and displacement materials based on the II test the highest (84%), the lowest (21%), and the non-misconceptions (7%). (3) The highest cause of misconception among students is associative thinking (22%) and the lowest is caused by incomplete or incomplete reasoning (11%). Three-Tier Diagnostic Test (TTDT) could identify the student's misconception of heat and temperature.
Smart Cup: A Minimally-Instrumented, Smartphone-Based Point-of-Care Molecular Diagnostic Device.
Liao, Shih-Chuan; Peng, Jing; Mauk, Michael G; Awasthi, Sita; Song, Jinzhao; Friedman, Harvey; Bau, Haim H; Liu, Changchun
2016-06-28
Nucleic acid amplification-based diagnostics offer rapid, sensitive, and specific means for detecting and monitoring the progression of infectious diseases. However, this method typically requires extensive sample preparation, expensive instruments, and trained personnel. All of which hinder its use in resource-limited settings, where many infectious diseases are endemic. Here, we report on a simple, inexpensive, minimally-instrumented, smart cup platform for rapid, quantitative molecular diagnostics of pathogens at the point of care. Our smart cup takes advantage of water-triggered, exothermic chemical reaction to supply heat for the nucleic acid-based, isothermal amplification. The amplification temperature is regulated with a phase-change material (PCM). The PCM maintains the amplification reactor at a constant temperature, typically, 60-65°C, when ambient temperatures range from 12 to 35°C. To eliminate the need for an optical detector and minimize cost, we use the smartphone's flashlight to excite the fluorescent dye and the phone camera to record real-time fluorescence emission during the amplification process. The smartphone can concurrently monitor multiple amplification reactors and analyze the recorded data. Our smart cup's utility was demonstrated by amplifying and quantifying herpes simplex virus type 2 (HSV-2) with LAMP assay in our custom-made microfluidic diagnostic chip. We have consistently detected as few as 100 copies of HSV-2 viral DNA per sample. Our system does not require any lab facilities and is suitable for use at home, in the field, and in the clinic, as well as in resource-poor settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent.
Jacobsberg, L; Perry, S; Frances, A
1995-12-01
Instruments to assess personality disorders offer reliability, but at the cost of large amounts of a skilled clinician's time to make assessments. The Structured Clinical Interview for DSM-III Axis II (SCID-II; Spitzer, Williams, Gibbon, & First, 1990), incorporates a self-report screening questionnaire, reducing the number of items needing evaluation by the interviewer. However, false negative responses may cause clinically important areas to be overlooked. To establish the rate of false negative responses, we compared participant self-report on the SCID-II with Axis II diagnostic assessment done by clinicians using the Personality Disorder Examination (Loranger, Susman, Oldham, & Russakoff, 1987). The false negative rate was low for every diagnosis, supporting validity of following up with clinician questioning only those diagnostic elements endorsed in the self-report. Avoidant and dependent personality disorders were accurately self-reported. This, an efficient assessment instrument for personality disorders might combine self-report of those disorders where self-report is reliable, with clinician assessment where needed.
Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak.
Pan, X M; Yang, Z J; Ma, X D; Zhu, Y L; Luhmann, N C; Domier, C W; Ruan, B W; Zhuang, G
2016-11-01
A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.
Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, X. M.; Yang, Z. J., E-mail: yangzj@hust.edu.cn; Ma, X. D.
2016-11-15
A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advancedmore » optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.« less
Optical Magnetic Induction Tomography of the Heart
NASA Astrophysics Data System (ADS)
Marmugi, Luca; Renzoni, Ferruccio
2016-04-01
Atrial Fibrillation (AF) affects a significant fraction of the ageing population, causing a high level of morbidity and mortality. Despite its significance, the causes of AF are still not uniquely identified. This, combined with the lack of precise diagnostic and guiding tools, makes the clinical treatment of AF sub-optimal. We identify magnetic induction tomography as the most promising technique for the investigation of the causes of fibrillation and for its clinical practice. We therefore propose a novel optical instrument based on optical atomic magnetometers, fulfilling the requirements for diagnostic mapping of the heart’s conductivity. The feasibility of the device is here discussed in view of the final application. Thanks to the potential of atomic magnetometers for miniaturisation and extreme sensitivity at room temperature, a new generation of compact and non-invasive diagnostic instrumentation, with both bedside and intra-operative operation capability, is envisioned. Possible scenarios both in clinical practice and biomedical research are then discussed. The flexibility of the system makes it promising also for application in other fields, such as neurology and oncology.
MOEMs devices for future astronomical instrumentation in space
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Liotard, Arnaud; Lanzoni, Patrick; ElHadi, Kacem; Waldis, Severin; Noell, Wilfried; de Rooij, Nico; Conedera, Veronique; Fabre, Norbert; Muratet, Sylvaine; Camon, Henri
2017-11-01
Based on the micro-electronics fabrication process, Micro-Opto-Electro-Mechanical Systems (MOEMS) are under study in order to be integrated in next-generation astronomical instruments for ground-based and space telescopes. Their main advantages are their compactness, scalability, specific task customization using elementary building blocks, and remote control. At Laboratoire d'Astrophysique de Marseille, we are engaged since several years in the design, realization and characterization of programmable slit masks for multi-object spectroscopy and micro-deformable mirrors for wavefront correction. First prototypes have been developed and show results matching with the requirements.
A Braille Interface to the Texas Instruments SR-52 Programmable Calculator.
1976-09-21
F / _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ AD—A039 US PENNSYLVANIA STATE UNIV JNIVtRSITY PARK APPLIED RESE——ETc F/G 9/2 * BRAILLE INTERFACE to PC TEXAS...UNCLASSiFIED A BRAILLE INTERFACE TO THE TEXAS INSTRUMENTS SR-52 PR0CRA)*~ABLE CALCULATOR C. P~ JANOTA Technical Memorandum D D C File No. TM 76-244 i...SUPPLEMENTARY NOTES ~~~~ ~ 15. KEY WORDS (ConUnti. on ,.v.ra• .Id. If nøc....ry and td~n t tf y by block ntanb.r) AIDS TO HANDICAPPED BRAILLE INTERFACE
Application of programmable logic controllers to space simulation
NASA Technical Reports Server (NTRS)
Sushon, Janet
1992-01-01
Incorporating a state-of-the-art process control and instrumentation system into a complex system for thermal vacuum testing is discussed. The challenge was to connect several independent control systems provided by various vendors to a supervisory computer. This combination will sequentially control and monitor the process, collect the data, and transmit it to color a graphic system for subsequent manipulation. The vacuum system upgrade included: replacement of seventeen diffusion pumps with eight cryogenic pumps and one turbomolecular pump, replacing a relay based control system, replacing vacuum instrumentation, and upgrading the data acquisition system.
Bellanger, Martine M; Jourdain, Alain
2004-01-01
This article aims to evaluate the results of two different approaches underlying the attempts to reduce health inequalities in France. In the 'instrumental' approach, resource allocation is based on an indicator to assess the well-being or the quality of life associated with healthcare provision, the argument being that additional resources would respond to needs that could then be treated quickly and efficiently. This governs the distribution of regional hospital budgets. In the second approach, health professionals and users in a given region are involved in a consensus process to define those priorities to be included in programme formulation. This 'procedural' approach is employed in the case of the regional health programmes. In this second approach, the evaluation of the results runs parallel with an analysis of the process using Rawlsian principles, whereas the first approach is based on the classical economic model.At this stage, a pragmatic analysis based on both the comparison of regional hospital budgets during the period 1992-2003 (calculated using a 'RAWP [resource allocation working party]-like' formula) and the evolution of regional health policies through the evaluation of programmes for the prevention of suicide, alcohol-related diseases and cancers provides a partial assessment of the impact of the two types of approaches, the second having a greater effect on the reduction of regional inequalities.
Teaching an engine-driven preparation technique to undergraduates: initial observations.
Hänni, S; Schönenberger, K; Peters, O A; Barbakow, F
2003-07-01
This paper describes the initial experiences following the introduction of a rotary engine-driven preparation technique into the undergraduate endodontic programme at the Zurich University Dental Centre. Forty third-year students practised the ProFile.04 (PF.04) technique between January and July 2001 in a preclinical course. Between November 2001 and February 2002, 20 of these students (Group A) root-treated 51 teeth in their clinical course using either PF.04, the balanced force technique (BFT) or a combination of both. The second group of 20 students (Group B) similarly treated another 36 randomly selected teeth between April and July 2002. Types of teeth treated by the students and the canal preparation techniques were recorded. The students also completed a short questionnaire, evaluating their opinions of the new course. Of the 87 teeth endodontically treated during the clinical course, 34, 14 and 39 were shaped using PF.04 alone, a combination of PF.04 and BFT and BFT alone, respectively. No rotary instruments were fractured during the 1-year clinical course, although some instruments were fractured during the preclinical laboratory course. Overall, the students rated the rotary technique as positive. A rotary technique was successfully introduced into an undergraduate endodontic programme (this will be continued in the foreseeable future). However, the continuity between the preclinical and the clinical courses was poor as a result of the constraints of the general teaching programme.
ERIC Educational Resources Information Center
Bourke, Roseanna; Dharan, Vijaya
2015-01-01
Psychologists working in education in Aotearoa/New Zealand work in diverse educational environments making day-to-day decisions informed by evidence-based practice. As a relatively small professional group with a complex work programme, they contribute to the assessments and decision-making processes of children and young people across multiple…
Evaluation of direct and indirect effects of seasonal malaria chemoprevention in Mali.
Druetz, Thomas
2018-05-25
Randomized controlled trials have established that seasonal malaria chemoprevention (SMC) in children is a promising strategy to reduce malaria transmission in Sahelian West Africa. This strategy was recently introduced in a dozen countries, and about 12 million children received SMC in 2016. However, evidence on SMC effectiveness under routine programme conditions is sparse. We aim to measure the effects of the nationwide SMC programme in Mali on the prevalence of malaria and anemia in children 6-59 months. We used data from the 2015 nationally representative malaria indicator survey. A post-test only with non-randomized control group study was designed. We fitted a generalized structural equation model that controlled for potential bias on observed and non-observed variables (endogenous treatment effect model). Having received SMC reduced by 44% (95% CI [0.39-0.49]) the risk of having a positive rapid diagnostic test for malaria. In addition, the programme indirectly reduced by 18% the risk of moderate-to-severe anemia (95% CI [0.15-0.21]). SMC in Mali has substantial protective effects under routine nationwide programme conditions. Endogenous treatment effects analyses can contribute to rigorously measuring the effectiveness of health programmes and to bridging a widening gap in evaluation methods to measure progress towards achieving malaria elimination.
NASA Astrophysics Data System (ADS)
Rana, Md. Muhit
DNA nanotechnology has shown great promise in molecular diagnostic, bioanalytical and biomedical applications. The great challenge of detecting target analytes, biomarkers and small molecules, in molecular diagnostics is low yield sensitivity. To address this challenge, different nanomaterials have been used for a long time and to date there is no such cost-effective bioanalytical technique which can detect these target biomarkers (DNA, RNA, circulating DNA/miRNA) or environmental heavy metal ions (Hg2+ and Ag+) in a cost-effective and efficient manner. Herein, we initially discuss two possible bioanalytical detection methods- a) colorimetric and b) fluorometric assays which are very popular nowadays due to their distinctive spectroscopic properties. Finally, we report the promising colorimetric assay using a novel DNA based amplification strategy know as hybridization chain reaction (HCR) for potential application in the visual detection of low copies of biomarkers (miRNAs as little as 20 femtomole in an RNA pool and cell extracts in seven different combinations and Ebola virus DNA as low as 400 attomoles in liquid biopsy mimics in sixteen different combinations), environmental and biological heavy metal ions (mercury and silver concentrations as low as 10 pM in water, soil and urine samples) and also successfully applied to a molecular logic gate operation to distinguish OR and AND logic gates. No results showed any false-positive or false-negative information. On the other hand, we also discuss the future possibilities of HCR amplification technology, which is very promising for fluorometric bioanalysis. The HCR based nanoprobe technology has numerous remarkable advantages over other methods. It is re-programmable, simple, inexpensive, easy to assemble and operate and can be performed with visual and spectroscopic read-outs upon recognition of the target analytes. This rapid, specific and sensitive approach for biomarkers and heavy metal ion detection generates an on-site signal while eliminating the use of sophisticated high-maintenance instrumentation. We demonstrate that this state-of-the-art technology and methodology can potentially serve as an alternative approach to detect novel disease biomarkers, small molecules and inorganic compounds. This approach can be combined with the current existing methods for real-time point-of-care molecular diagnostics and is significant for preclinical or clinical studies.
Development of PETAL diagnostics: PETAPhys project
NASA Astrophysics Data System (ADS)
Raffestin, D.; Boutoux, G.; Baggio, J.; Batani, D.; Blanchot, N.; Bretheau, D.; Hulin, S.; D'Humieres, E.; Granet, F.; Longhi, Th.; Meyer, Ch.; Moreno, Q.; Nuter, R.; Rault, J.; Tikhonchuk, V.; Universite de Bordeaux/Celia Team; CEA. DAM/Cesta Team
2017-10-01
Beginning of autumn 2017, PETAL, a Petawatt laser beam, will be operated for experiments on the LMJ facility at the CEA/ Cesta research center. The PETAPhys project provides a support to the qualification phase of the PETAL laser operation. Within the PETAPhys project, we are developing two simple and robust diagnostics permitting both to characterize the focal spot of the PETAL beam and to measure the hard X-ray spectrum at each shot. The first diagnostic consists in optical imaging of the PETAL beam focal spot in the spectral range of the second and third harmonic radiation emitted from the target. The second diagnostic is a hard X-ray dosimeter consisting in a stack of imaging plates (IP) and filters, either placed inside a re-entrant tube or inserted close to target. Numerical simulations as well as experiments on small scale facilities have been performed to design these diagnostics. If available, preliminary results from PETAL experiments will be discussed. We acknowledge the financial support from the French National Research Agency (ANR) in the framework of ``the investments for the future'' Programme IdEx Bordeaux-LAPHIA (ANR-10-IDEX-03-02).
De Clercq, K; Goris, N; Barnett, P V; MacKay, D K
2008-01-01
The last decade international trade in animals and animal products was liberated and confidence in this global trade can increase only if appropriate control measures are applied. As foot-and-mouth disease (FMD) diagnostics will play an essential role in this respect, the Food and Agriculture Organization European Commission for the Control of Foot-and-Mouth Disease (EUFMD) co-ordinates, in collaboration with the European Commission, several programmes to increase the quality of FMD diagnostics. A quality assurance (QA) system is deemed essential for laboratories involved in certifying absence of FMDV or antibodies against the virus. Therefore, laboratories are encouraged to validate their diagnostic tests fully and to install a continuous quality control (QC) monitoring system. Knowledge of performance characteristics of diagnostics is essential to interpret results correctly and to calculate sample rates in regional surveillance campaigns. Different aspects of QA/QC of classical and new FMD virological and serological diagnostics are discussed in respect to the EU FMD directive (2003/85/EC). We recommended accepting trade certificates only from laboratories participating in international proficiency testing on a regular basis.
Development of stimulation diagnostic technology. Annual report, May 1990--December 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warpinski, N.R.; Lorenz, J.C.
The objective of this project is to apply Sandia`s expertise and technology towards the development of stimulation diagnostic technology in the areas of in situ stress, natural fracturing, stimulation processes and instrumentation systems. Initial work has concentrated on experiment planning for a site where hydraulic fracturing could be evaluated and design models and fracture diagnostics could be validated and improved. Important issues have been defined and new diagnostics, such as inclinometers, identified. In the area of in situ stress, circumferential velocity analysis is proving to be a useful diagnostic for stress orientation. Natural fracture studies of the Frontier formation aremore » progressing; two fracture sets have been found and their relation to tectonic events have been hypothesized. Analyses of stimulation data have been performed for several sites, primarily for in situ stress information. Some new ideas in stimulation diagnostics have been proposed; these ideas may significantly improve fracture diagnostic capabilities.« less
Development of stimulation diagnostic technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warpinski, N.R.; Lorenz, J.C.
The objective of this project is to apply Sandia's expertise and technology towards the development of stimulation diagnostic technology in the areas of in situ stress, natural fracturing, stimulation processes and instrumentation systems. Initial work has concentrated on experiment planning for a site where hydraulic fracturing could be evaluated and design models and fracture diagnostics could be validated and improved. Important issues have been defined and new diagnostics, such as inclinometers, identified. In the area of in situ stress, circumferential velocity analysis is proving to be a useful diagnostic for stress orientation. Natural fracture studies of the Frontier formation aremore » progressing; two fracture sets have been found and their relation to tectonic events have been hypothesized. Analyses of stimulation data have been performed for several sites, primarily for in situ stress information. Some new ideas in stimulation diagnostics have been proposed; these ideas may significantly improve fracture diagnostic capabilities.« less
The New Meteor Radar at Penn State: Design and First Observations
NASA Technical Reports Server (NTRS)
Urbina, J.; Seal, R.; Dyrud, L.
2011-01-01
In an effort to provide new and improved meteor radar sensing capabilities, Penn State has been developing advanced instruments and technologies for future meteor radars, with primary objectives of making such instruments more capable and more cost effective in order to study the basic properties of the global meteor flux, such as average mass, velocity, and chemical composition. Using low-cost field programmable gate arrays (FPGAs), combined with open source software tools, we describe a design methodology enabling one to develop state-of-the art radar instrumentation, by developing a generalized instrumentation core that can be customized using specialized output stage hardware. Furthermore, using object-oriented programming (OOP) techniques and open-source tools, we illustrate a technique to provide a cost-effective, generalized software framework to uniquely define an instrument s functionality through a customizable interface, implemented by the designer. The new instrument is intended to provide instantaneous profiles of atmospheric parameters and climatology on a daily basis throughout the year. An overview of the instrument design concepts and some of the emerging technologies developed for this meteor radar are presented.
Adaptive Instrument Module: Space Instrument Controller "Brain" through Programmable Logic Devices
NASA Technical Reports Server (NTRS)
Darrin, Ann Garrison; Conde, Richard; Chern, Bobbie; Luers, Phil; Jurczyk, Steve; Mills, Carl; Day, John H. (Technical Monitor)
2001-01-01
The Adaptive Instrument Module (AIM) will be the first true demonstration of reconfigurable computing with field-programmable gate arrays (FPGAs) in space, enabling the 'brain' of the system to evolve or adapt to changing requirements. In partnership with NASA Goddard Space Flight Center and the Australian Cooperative Research Centre for Satellite Systems (CRC-SS), APL has built the flight version to be flown on the Australian university-class satellite FEDSAT. The AIM provides satellites the flexibility to adapt to changing mission requirements by reconfiguring standardized processing hardware rather than incurring the large costs associated with new builds. This ability to reconfigure the processing in response to changing mission needs leads to true evolveable computing, wherein the instrument 'brain' can learn from new science data in order to perform state-of-the-art data processing. The development of the AIM is significant in its enormous potential to reduce total life-cycle costs for future space exploration missions. The advent of RAM-based FPGAs whose configuration can be changed at any time has enabled the development of the AIM for processing tasks that could not be performed in software. The use of the AIM enables reconfiguration of the FPGA circuitry while the spacecraft is in flight, with many accompanying advantages. The AIM demonstrates the practicalities of using reconfigurable computing hardware devices by conducting a series of designed experiments. These include the demonstration of implementing data compression, data filtering, and communication message processing and inter-experiment data computation. The second generation is the Adaptive Processing Template (ADAPT) which is further described in this paper. The next step forward is to make the hardware itself adaptable and the ADAPT pursues this challenge by developing a reconfigurable module that will be capable of functioning efficiently in various applications. ADAPT will take advantage of radiation tolerant RAM-based field programmable gate array (FPGA) technology to develop a reconfigurable processor that combines the flexibility of a general purpose processor running software with the performance of application specific processing hardware for a variety of high performance computing applications.
A New Framework for Designing Programmes of Assessment
ERIC Educational Resources Information Center
Dijkstra, J.; Van der Vleuten, C. P. M.; Schuwirth, L. W. T.
2010-01-01
Research on assessment in medical education has strongly focused on individual measurement instruments and their psychometric quality. Without detracting from the value of this research, such an approach is not sufficient to high quality assessment of competence as a whole. A programmatic approach is advocated which presupposes criteria for…
Collaborating and Creating on Music Technologies
ERIC Educational Resources Information Center
Dillon, Teresa
2003-01-01
Across all UK secondary school subject areas the proliferation of information and communication technologies (ICTs) has changed the nature of learning. Music education now includes the use of digital tools, such as programmable keyboards and computers, as key learning and music making instruments. Despite such usage there is relatively little…
78 FR 21387 - Notice of Issuance of Final Determination Concerning Printer and Fax Machine
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-10
... in part of materials from another country or instrumentality, it has been substantially transformed... loading the firmware onto the print engine. In determining whether the combining of parts or materials... foreign Programmable Read Only Memory Chip (``PROM'') in the United States substantially transformed the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
... in part of materials from another country or instrumentality, it has been substantially transformed... the combining of parts or materials constitutes a substantial transformation, the determinative issue... States), the programming of a foreign PROM (Programmable Read-Only Memory chip) in the United States...
Using a Programmable Calculator to Teach Teophylline Pharmacokinetics.
ERIC Educational Resources Information Center
Closson, Richard Grant
1981-01-01
A calculator program for a Texas Instruments Model 59 to predict serum theophylline concentrations is described. The program accommodates the input of multiple dose times at irregular intervals, clearance changes due to concurrent patient diseases and age less than 17 years. The calculations for five hypothetical patients are given. (Author/MLW)
Pre-School Children's Encounters with "The Magic Flute"
ERIC Educational Resources Information Center
Nyland, Berenice; Acker, Aleksandra; Ferris, Jill; Deans, Jan
2011-01-01
This article describes a music programme in an Australian early learning centre. Through a repertoire of songs, games and instruments, the children were introduced to music forms, including opera. Mozart's Magic Flute was presented to these children by watching the Metropolitan Opera's latest film performance. Because this opera seized the…
Reframing European Doctoral Training for the New ERA
ERIC Educational Resources Information Center
Repeckaite, Daiva
2016-01-01
In 2014 the institutionalization of European higher education and training, as well as research and innovation, policy entered a new phase: a number of financial instruments were simplified and merged. The Erasmus Mundus programme, wherein consortia of European and overseas universities built joint master's or doctoral degrees, was split into two…
Authentic Practices as Contexts for Learning to Draw Inferences beyond Correlated Data
ERIC Educational Resources Information Center
Dierdorp, Adri; Bakker, Arthur; Eijkelhof, Harrie; van Maanen, Jan
2011-01-01
To support 11th-grade students' informal inferential reasoning, a teaching and learning strategy was designed based on authentic practices in which professionals use correlation or linear regression. These practices included identifying suitable physical training programmes, dyke monitoring, and the calibration of measurement instruments. The…
NASA Technical Reports Server (NTRS)
Kurth, William S.
1991-01-01
The Plasma Diagnostics Package (PDP) is a spacecraft which was designed and built at The University of Iowa and which contained several scientific instruments. These instruments were used for measuring Space Shuttle Orbiter environmental parameters and plasma parameters. The PDP flew on two Space Shuttle flights. The first flight of the PDP was on Space Shuttle Mission STS-3 and was a part of the NASA/Office of Space Science payload (OSS-1). The second flight of the PDP was on Space Shuttle Mission STS/51F and was a part of Spacelab 2. The interpretation of both the OSS-1 and Spacelab 2 PDP results in terms of large space structure plasma interactions is emphasized.
Recent Beam Measurements and New Instrumentation at the Advanced Light Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sannibale, F.; Baptiste, K.; Barry, W.
2012-04-11
The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and usedmore » in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.« less
RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter
2008-05-05
The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and usedmore » in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.« less
Concept of a programmable maintenance processor applicable to multiprocessing systems
NASA Technical Reports Server (NTRS)
Glover, Richard D.
1988-01-01
A programmable maintenance processor concept applicable to multiprocessing systems has been developed at the NASA Ames Research Center's Dryden Flight Research Facility. This stand-alone-processor is intended to provide support for system and application software testing as well as hardware diagnostics. An initial machanization has been incorporated into the extended aircraft interrogation and display system (XAIDS) which is multiprocessing general-purpose ground support equipment. The XAIDS maintenance processor has independent terminal and printer interfaces and a dedicated magnetic bubble memory that stores system test sequences entered from the terminal. This report describes the hardware and software embodied in this processor and shows a typical application in the check-out of a new XAIDS.
Kohlmann, Alexander; Kipps, Thomas J; Rassenti, Laura Z; Downing, James R; Shurtleff, Sheila A; Mills, Ken I; Gilkes, Amanda F; Hofmann, Wolf-Karsten; Basso, Giuseppe; Dell’Orto, Marta Campo; Foà, Robin; Chiaretti, Sabina; De Vos, John; Rauhut, Sonja; Papenhausen, Peter R; Hernández, Jesus M; Lumbreras, Eva; Yeoh, Allen E; Koay, Evelyn S; Li, Rachel; Liu, Wei-min; Williams, Paul M; Wieczorek, Lothar; Haferlach, Torsten
2008-01-01
Gene expression profiling has the potential to enhance current methods for the diagnosis of haematological malignancies. Here, we present data on 204 analyses from an international standardization programme that was conducted in 11 laboratories as a prephase to the Microarray Innovations in LEukemia (MILE) study. Each laboratory prepared two cell line samples, together with three replicate leukaemia patient lysates in two distinct stages: (i) a 5-d course of protocol training, and (ii) independent proficiency testing. Unsupervised, supervised, and r2 correlation analyses demonstrated that microarray analysis can be performed with remarkably high intra-laboratory reproducibility and with comparable quality and reliability. PMID:18573112
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays.
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-19
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.
An ultra-low-cost smartphone octochannel spectrometer for mobile health diagnostics.
Wang, Li-Ju; Naudé, Nicole; Chang, Yu-Chung; Crivaro, Anne; Kamoun, Malek; Wang, Ping; Li, Lei
2018-03-30
With the rapid development and proliferation of mobile devices with powerful computing power and the ability of integrating sensors into mobile devices, the potential impact of mobile health (mHealth) diagnostics on the public health is drawing researchers' attention. We developed a Smartphone Octo-channel Spectrometer (SOS) as a mHealth diagnostic tool. The SOS has nanoscale wavelength resolution, is self-illuminated from the smartphone itself, and is ultra-low cost (less than $20). A user interface controls the optical sensing parameters and precise alignment. After calibrating and testing the SOS by quantifying protein concentrations, we clinically validated the SOS by comparing the diagnostic performance of our device with that of a clinical spectrophotometer. About 180 serum samples from de-identified patients with 4 types of autoantibodies were blindly read the ELISA results. The accuracy of the SOS achieved 100% across the clinical reportable range compared with the FDA-approved instrument. Furthermore, the self-illuminated SOS only requires about half of the light intensity of the FDA-approved instrument to achieve clinical-level sensitivity. The low-energy-consumption and low-cost SOS enables point-of-care spectrophotometric sensing in low-resource areas, and can be integrated into point-of-care diagnostic systems for rapid multiplex readout and analysis at patient bedside or at home. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Malaria community health workers in Myanmar: a cost analysis.
Kyaw, Shwe Sin; Drake, Tom; Thi, Aung; Kyaw, Myat Phone; Hlaing, Thaung; Smithuis, Frank M; White, Lisa J; Lubell, Yoel
2016-01-25
Myanmar has the highest malaria incidence and attributed mortality in South East Asia with limited healthcare infrastructure to manage this burden. Establishing malaria Community Health Worker (CHW) programmes is one possible strategy to improve access to malaria diagnosis and treatment, particularly in remote areas. Despite considerable donor support for implementing CHW programmes in Myanmar, the cost implications are not well understood. An ingredients based micro-costing approach was used to develop a model of the annual implementation cost of malaria CHWs in Myanmar. A cost model was constructed based on activity centres comprising of training, patient malaria services, monitoring and supervision, programme management, overheads and incentives. The model takes a provider perspective. Financial data on CHWs programmes were obtained from the 2013 financial reports of the Three Millennium Development Goal fund implementing partners that have been working on malaria control and elimination in Myanmar. Sensitivity and scenario analyses were undertaken to outline parameter uncertainty and explore changes to programme cost for key assumptions. The range of total annual costs for the support of one CHW was US$ 966-2486. The largest driver of CHW cost was monitoring and supervision (31-60% of annual CHW cost). Other important determinants of cost included programme management (15-28% of annual CHW cost) and patient services (6-12% of annual CHW cost). Within patient services, malaria rapid diagnostic tests are the major contributor to cost (64% of patient service costs). The annual cost of a malaria CHW in Myanmar varies considerably depending on the context and the design of the programme, in particular remoteness and the approach to monitoring and evaluation. The estimates provide information to policy makers and CHW programme planners in Myanmar as well as supporting economic evaluations of their cost-effectiveness.
Waldorff, Frans Boch; Steenstrup, Annette Plesner; Nielsen, Bente; Rubak, Jens; Bro, Flemming
2008-01-01
Background We were unable to identify studies that have considered the diffusion of an e-learning programme among a large population of general practitioners. The aim of this study was to investigate the uptake of an e-learning programme introduced to General Practitioners as part of a nation-wide disseminated dementia guideline. Methods A prospective study among all 3632 Danish GPs. The GPs were followed from the launching of the e-learning programme in November 2006 and 6 months forward. Main outcome measures: Use of the e-learning programme. A logistic regression model (GEE) was used to identify predictors for use of the e-learning programme. Results In the study period, a total of 192 different GPs (5.3%) were identified as users, and 17% (32) had at least one re-logon. Among responders at first login most have learnt about the e-learning programme from written material (41%) or from the internet (44%). A total of 94% of the users described their ability of conducting a diagnostic evaluation as good or excellent. Most of the respondents used the e-learning programme due to general interest (90%). Predictors for using the e-learning programme were Males (OR = 1.4, 95% CI 1.1; 2.0) and members of Danish College of General Practice (OR = 2.2, 95% CI 1.5; 3.1), whereas age, experience and working place did not seem to be influential. Conclusion Only few Danish GPs used the e-learning programme in the first 6 months after the launching. Those using it were more often males and members of Danish College of General Practice. Based on this study we conclude, that an active implementation is needed, also when considering electronic formats of CME like e-learning. Trial Registration ClinicalTrials.gov Identifier: NCT00392483. PMID:18439279
The Radio & Plasma Wave Investigation (RPWI) for JUICE - Instrument Concept and Capabilities
NASA Astrophysics Data System (ADS)
Bergman, J. E. S.
2013-09-01
We present the concept and capabilities of the Radio & Plasma Waves Investigation (RPWI) instrument for the JUICE mission. The RPWI instrument provides measurements of plasma, electric- and magnetic field fluctuations from near DC up to 45 MHz. The RPWI sensors are four Langmuir probes for low temperature plasma diagnostics and electric field measurements, a three-axis searchcoil magnetometer for low-frequency magnetic field measurements, and a three-axial radio antenna, which operates from 80 kHz up to 45 MHz and thus gives RPWI remote sensing capabilities.. In addition, active mutual impedance measurements are used to diagnose the in situ plasma. The RPWI instrument is unique as it provides vector field measurements in the whole frequency range. This makes it possible to employ advanced diagnostics techniques, which are unavailable for scalar measurements. The RPWI instrument has thus outstanding new capabilities not previously available to outer planet missions, which and enables RPWI to address many fundamental planetary science objectives, such as the electrodynamic influence of the Jovian magnetosphere on the exospheres, surfaces and conducting oceans of Ganymede, Europa, and Callisto. RPWI will also be able to investigate the sources of radio emissions from auroral regions of Ganymede and Jupiter, in detail and with unprecedented sensitivity, and possibly also lightning. Moreover, RPWI can search for exhaust plumes from cracks on the icy moons, as well as μm-sized dust and related dust-plasmasurface interaction processes occurring near the icy moons of Jupiter. The top-level blockdiagram of the RPWI instrument is shown here. A detailed technical description of the RPWI instrument will be given.
Instrumentation for localized superconducting cavity diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conway, Z. A.; Ge, M.; Iwashita, Y.
2017-01-12
Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.
NASA Technical Reports Server (NTRS)
Meyer, Scott A.; Bershader, Daniel; Sharma, Surendra P.; Deiwert, George S.
1996-01-01
Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.
[Peculiarities of the early diagnostics of malignant nasopharyngal neoplasms].
Baryshev, V V; Andreev, V G; Sevryukov, F E; Buyakova, M E; Akki, E D
The authors consider the risk factors and the specific clinical symptoms of the malignant nasopharyngal neoplasms as well as the methods for instrumental, laboratory, and pathomorphological diagnostics of this pathology. The full scale implementation of the recommendations for the timely detection of the tumours using the aforementioned diagnostic procedures and tests makes it possible to reduce to a minimum the interval between the establishment of the diagnosis and the onset of the relevant treatment at the early stages of the disease and thereby to ensure the improvement of its long-term outcomes.
Diagnostic devices for isothermal nucleic acid amplification.
Chang, Chia-Chen; Chen, Chien-Cheng; Wei, Shih-Chung; Lu, Hui-Hsin; Liang, Yang-Hung; Lin, Chii-Wann
2012-01-01
Since the development of the polymerase chain reaction (PCR) technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development.
Diagnostic Devices for Isothermal Nucleic Acid Amplification
Chang, Chia-Chen; Chen, Chien-Cheng; Wei, Shih-Chung; Lu, Hui-Hsin; Liang, Yang-Hung; Lin, Chii-Wann
2012-01-01
Since the development of the polymerase chain reaction (PCR) technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development. PMID:22969402
Manuela Baietto; A. Dan Wilson; Daniele Bassi; Francesco Ferrini
2008-01-01
The tree stability-assessment methodology currently used in Italian cities initially follows a visual analysis of individual trees, followed by an evaluation of the internal state using different instruments that are often invasive, expensive, or cannot be effectively used in the urban environment. Moreover, many of these instruments do not provide an adequate...
ERIC Educational Resources Information Center
Martini, Mary
The Preschool Language Assessment Instrument (PLAI) was designed as a diagnostic tool for 3- to 6-year-old children to assess children's abilities to use language to solve thinking problems typically posed by teachers. The PLAI was developed after observing middle-class teachers in preschool classrooms encourage children to use language in…
ERIC Educational Resources Information Center
Tsui, Chi-Yan; Treagust, David
2010-01-01
While genetics has remained as one key topic in school science, it continues to be conceptually and linguistically difficult for students with the concomitant debates as to what should be taught in the age of biotechnology. This article documents the development and implementation of a two-tier multiple-choice instrument for diagnosing grades 10…
Portable dynamic fundus instrument
NASA Technical Reports Server (NTRS)
Taylor, Gerald R. (Inventor); Meehan, Richard T. (Inventor); Hunter, Norwood R. (Inventor); Caputo, Michael P. (Inventor); Gibson, C. Robert (Inventor)
1992-01-01
A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.
From CIRCUS to EL CIRCO: Issues in Instrument Development for Young Spanish-speaking Children.
ERIC Educational Resources Information Center
Hardy, Roy
The CIRCO project is a large scale effort to design a series of diagnostic instruments, based on the CIRCUS tests, for Spanish-speaking children in preschool, kindergarten, and first grade classrooms in the United States. The goal is to develop measures with the following characteristics: (1) is suitable for use with Spanish-speaking children from…
ERIC Educational Resources Information Center
LoPresto, Michael C.; Murrell, Steven R.
2009-01-01
The Star Properties Concept Inventory (SPCI) is among the first instruments made available to assess student gains in a major section or "unit" of a traditional introductory astronomy course, in this case the unit on stars. This is in contrast to instruments for an entire course, such as the Astronomy Diagnostic Test or the Lunar Phases…
ERIC Educational Resources Information Center
Cheong, Irene Poh-Ai; Johari, Marliza; Said, Hardimah; Treagust, David F.
2015-01-01
The need for renewable and non-fossil fuels is now recognised by nations throughout the world. Consequently, an understanding of alternative energy is needed both in schools and in everyday life-long learning situations. This study developed a two-tier instrument to diagnose students' understanding and alternative conceptions about alternative…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, X. Y.; Chen, Z. J.; Zhang, X.
The 2.5 MeV neutron spectrometer TOFED (Time-Of-Flight Enhanced Diagnostics) has been constructed to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas on EAST. The instrument has a double-ring structure which, in combination with pulse shape digitization, allows for a dual kinematic selection in the time-of-flight/recoil proton energy (tof/E{sub p}) space, thus improving the spectrometer capability to resolve fast ion signatures in the neutron spectrum, in principle up to a factor ≈100. The identification and separation of features from the energetic ions in the neutron spectrum depends on the detailed knowledge of the instrument response function, both in terms ofmore » the light output function of the scintillators and the effect of undesired multiple neutron scatterings in the instrument. This work presents the determination of the light output function of the TOFED plastic scintillator detectors and their geometrical assembly. Results from dedicated experiments with γ-ray sources and quasi-monoenergetic neutron beams are presented. Implications on the instrument capability to perform background suppression based on double kinematic selection are discussed.« less
Paranoia.Ada: A diagnostic program to evaluate Ada floating-point arithmetic
NASA Technical Reports Server (NTRS)
Hjermstad, Chris
1986-01-01
Many essential software functions in the mission critical computer resource application domain depend on floating point arithmetic. Numerically intensive functions associated with the Space Station project, such as emphemeris generation or the implementation of Kalman filters, are likely to employ the floating point facilities of Ada. Paranoia.Ada appears to be a valuabe program to insure that Ada environments and their underlying hardware exhibit the precision and correctness required to satisfy mission computational requirements. As a diagnostic tool, Paranoia.Ada reveals many essential characteristics of an Ada floating point implementation. Equipped with such knowledge, programmers need not tremble before the complex task of floating point computation.
A digital wide range neutron flux measuring system for HL-2A
NASA Astrophysics Data System (ADS)
Yuan, Chen; Wu, Jun; Yin, Zejie
2017-08-01
To achieve wide-range, high-integration, and real-time performance on the neutron flux measurement on the HL-2A tokamak, a digital neutron flux measuring (DNFM) system based on the peripheral component interconnection (PCI) eXtension for Instrumentation express (PXIe) bus was designed. This system comprises a charge-sensitive preamplifier and a field programmable gate array (FPGA)-based main electronics plug-in. The DNFM totally covers source-range and intermediate-range neutron flux measurements, and increases system integration by a large margin through joining the pulse-counting mode and Campbell mode. Meanwhile, the neutron flux estimation method based on pulse piling proportions is able to choose and switch measuring modes in accordance with current flux, and this ensures the accuracy of measurements when the neutron flux changes suddenly. It has been demonstrated by simulated signals that the DNFM enhances the full-scale measuring range up to 1.9 × 108 cm-2 s-1, with relative error below 6.1%. The DNFM has been verified to provide a high temporal sensitivity at 10 ms time intervals on a single fission chamber on HL-2A. Contributed paper, published as part of the Proceedings of the 3rd Domestic Electromagnetic Plasma Diagnostics Workshop, September 2016, Hefei, China.
An examination of concussion education programmes: a scoping review methodology.
Caron, Jeffrey G; Bloom, Gordon A; Falcão, William R; Sweet, Shane N
2015-10-01
The primary purpose was to review the literature on concussion education programmes. The secondary purpose was to inform knowledge translation strategies for concussion researchers and practitioners. Research on concussion education programmes is relatively new. As a result, the current study implemented a scoping review methodology, which is a type of literary search used to provide a preliminary assessment of the size and scope of a body of literature, as well as identify strengths, weaknesses and gaps in the research. A five-stage process for conducting a scoping review was followed for this study: (a) identifying the research questions, (b) identifying relevant studies, (c) identifying the study selection criteria, (d) charting the data and (e) reporting the results. Concussion education programmes have been developed and implemented with populations ranging in age from 9 to 49 years and have used interactive oral presentations, educational videos and computer-based learning programmes. Although the content of these programmes varied, the topics generally addressed salient aspects of concussion injury and recovery. Quantitative instruments have been the preferred methods for assessment. Education programmes aimed at improving participants' long-term concussion knowledge, behaviours and attitudes of concussions are needed. Researchers must consider using a knowledge translation framework to enhance concussion education programmes. The application of such a framework can lead to novel and interesting ways of disseminating information about concussive injury and recovery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
The future of medical diagnostics: review paper
2011-01-01
While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions. PMID:21861912
Heiberg Engel, Peter Johan
2008-01-01
Much education--especially at the university level--has been criticized for having primarily dealt with explicit knowledge, i.e. those aspects of mental activities, which are verbal and conscious. Furthermore, research in medical diagnostic reasoning has been criticized for having focused on the specialty of intern medicine, while specialties with other skills, i.e. perceptive skills within pathology and radiology, have been ignored. To show that the concept of tacit knowledge is important in medical education-at all levels and in medical diagnostic reasoning. Describing how tacit knowledge according to Michael Polany, is experienced and expressed in day-to-day life, it is shown that there is a tacit dimension to all knowledge. Reviewing recent literature on medical diagnostic reasoning, it is shown that tacit knowledge is recognized in connection with concepts such as "non-analytical reasoning" and "dual process of reasoning." It is important that educators are trained in how explicit and implicit knowledge is attained and that tacit knowledge is included in educational programmes of all medical specialties.
Life expectancies for individuals with psychiatric diagnoses.
Hannerz, H; Borgå, P; Borritz, M
2001-09-01
The aim of the study was to estimate life expectancies in different diagnostic groups for individuals treated as inpatients at Swedish psychiatric clinics. All individuals, older than 18 y and alive on the first of January 1983, who had been registered in the National Hospital Discharge Registry by a psychiatric clinic in 1978-82, were monitored for mortality during 1983 by using the National Cause of Death Registry. The study group consisted of 91 385 men and 77 217 women. The patients were divided into nine diagnostic groups according to the principal diagnosis registered at the latest discharge. Actuarial mathematics was used to construct life expectancy tables, which present the number of years expected to live, by gender and diagnostic group. Expectancies of life were significantly shortened for both genders and in all nine diagnostic groups (with one exception). Mental disorders in general are life shortening. This fact should be recognised in community health when setting health priorities. It should also be addressed in curricula as well as in treatment and preventive programmes.
Peeling, Rosanna W
2015-11-01
Diagnostics play a critical role in clinical decision making, and in disease control and prevention. Rapid point-of-care (POC) tests for infectious diseases can improve access to diagnosis and patient management, but the quality of these tests vary, quality of testing is often not assured and there are few mechanisms to capture test results for surveillance when the testing is so decentralised. A new generation of POC molecular tests that are highly sensitive and specific, robust and easy to use are now available for deployment in low resource settings. Decentralisation of testing outside of the laboratory can put tremendous stress on the healthcare system and presents challenges for training and quality assurance. A feature of many of these POC molecular devices is that they are equipped with data transmission capacities. In a digital age, it is possible to link data from diagnostic laboratories and POC test readers and devices to provide data on testing coverage, disease trends and timely information for early warning of infectious disease outbreaks to inform design or optimisation of disease control and elimination programmes. Data connectivity also allows control programmes to monitor the quality of tests and testing, and optimise supply chain management; thus, increasing the efficiency of healthcare systems and improving patient outcomes. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
ERIC Educational Resources Information Center
Galanter, Cathryn A.; Hundt, Stephanie R.; Goyal, Parag; Le, Jenna; Fisher, Prudence W.
2012-01-01
Objective: The "DSM-IV-TR "criteria for a manic episode and bipolar disorder (BD) were developed for adults but are used for children. The manner in which clinicians and researchers interpret these criteria may have contributed to the increase in BD diagnoses given to youth. Research interviews are designed to improve diagnostic reliability and…
Basic aerodynamic research facility for comparative studies of flow diagnostic techniques
NASA Technical Reports Server (NTRS)
Jones, Gregory S.; Gartrell, Luther R.; Stainback, P. Calvin
1987-01-01
Current flow diagnostic research efforts are focusing on higher order flow field data bases, such as those generated by laser velocimetry (LV), hot-wire anemometry, and multi-hole pressure probes. Recent low-speed comparisons of results obtained with LV and hot wires have revealed strengths and weaknesses of each instrument. A seeding study will be initiated to determine particulate tracking ability.
ERIC Educational Resources Information Center
Yan, Yaw Kai; Subramaniam, R.
2018-01-01
This study focused on grade 12 students' understanding of reaction kinetics. A 4-tier diagnostic instrument was developed for this purpose and administered to 137 students in the main study. Findings showed that reaction kinetics is a difficult topic for these students, with a total of 25 alternative conceptions (ACs) being uncovered. Except for…
ERIC Educational Resources Information Center
Ruscio, John; Brown, Timothy A.; Ruscio, Ayelet Meron
2009-01-01
Most taxometric studies of depressive constructs have drawn indicators from self-report instruments that do not bear directly on the "Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV)" diagnostic construct of major depressive disorder (MDD). The present study examined the latent structure of MDD using indicator sets…
Geimer, Sabina Andersson
2013-02-01
This thesis addresses several aspects of glaucoma diagnostics from both a clinical and a screening perspective. New instruments for diagnosing glaucoma have been developed over the past years, but little information is available regarding their performance as screening methods and their usefulness in ordinary clinical practice. PURPOSE OF THE RESEARCH UNDERLYING THIS THESIS: The objectives of this research were as follows: to compare the accuracy of results of analysis of the optic nerve head (ONH) achieved by computerized imaging using the Heidelberg Retina Tomograph (HRT) and by subjective assessment performed by physicians with different degrees of experience of glaucoma (paper III); to evaluate the effect of a continuous medical education (CME) lecture on subjective assessment of the ONH for diagnosis of glaucoma (paper II); to investigate subjective assessment of perimetric test results by physicians with varying knowledge of glaucoma with a trained artificial neural network (ANN) and to compare the certainty of the classifications (paper IV); and to compare the diagnostic performance of time-domain Stratus optical coherence tomography (OCT) with that of spectral-domain Cirrus OCT (paper I), frequency doubling technology (FDT) screening perimetry and scanning laser polarimetry with the GDx variable corneal compensator (VCC) in a random population-based sample and in patients with glaucoma of varying disease severity. In evaluation of the ONH, use of the HRT statistical tools, Moorfields regression analysis (MRA) and the Glaucoma Probability Score (GPS) was compared with subjective assessment performed by 45 physicians. Optic nerve head images and photographs from 138 healthy and 97 glaucoma subjects were included. The sensitivity of MRA was higher (87-94%) than that of the average physician (62-82%), considerably greater than that of ophthalmologists with subspecialties other than glaucoma (53-77%) and non-significantly better than that of glaucoma experts (72-88%). Sensitivity achieved by GPS (79-93%) was also greater than that of the average physician. MRA correctly classified all eyes with advanced glaucomatous visual field defects, a result that was not achieved by GPS or even by the glaucoma experts. In eyes with small discs, MRA sensitivity (88%) was comparable with that of glaucoma experts (85%) and much better than that of GPS (50%). Also, the group comprising all physicians provided specificity (75-92%) similar to that of both MRA (69 - 86%) and GPS (72-94%) (Andersson et al. 2011a). A 1-hr CME lecture on ONH assessment led to a significant improvement in sensitivity (from 70% to 80%) and a significant decrease in uncertain assessments (from 22% to 13%), whereas specificity remained unchanged (68%) (Andersson et al. 2011b). A rise in sensitivity was seen in all subgroups of physicians, including glaucoma experts. Thirty physicians assessing standard automated perimetry (SAP) test results as Humphrey Field Analyzer single-field analysis printouts with full StatPac information from 99 patients with glaucoma and 66 healthy subjects were compared with a trained ANN regarding diagnostic performance. ANN reached significantly higher sensitivity (93%) than the average physician (83%), whereas specificity was similar for these two groups (91% and 90%, respectively). Diagnostic accuracy was similar among the different groups of physicians and seemingly rather independent of experience. Sensitivity ranged from 82% in the subgroup of other subspecialists to 87% in the glaucoma expert group, and specificity ranged from 88% among general ophthalmologists to 91% for glaucoma experts. The ANN attained certainty of classification that was in parity with that provided by the glaucoma experts and did not make any completely incorrect classifications of the visual fields (i.e. erroneous classifications were in the borderline zone) (Andersson et al. 2012). From a population-based randomly selected sample (n=308) of older subjects (aged ≥ 50 years) living in southern Sweden, 170 subjects underwent a comprehensive examination that included Stratus OCT, Cirrus OCT, an FDT screening programme and the GDx VCC. The same test protocol was applied to 138 randomized clinical patients with different stages of glaucoma. In the population-based sample, both Stratus and Cirrus OCT showed high diagnostic accuracy with area under the receiver-operating curve (aROC) values close to 1.0 (Bengtsson et al. 2012). Both OCT instruments correctly classified all of the clinical glaucoma patients with advanced disease. FDT screening showed high sensitivity (91%) but erroneously gave normal test results for some eyes with advanced disease. GDx VCC had lower sensitivity (73-92%) and also led to a large proportion of examinations with an atypical retardation pattern that is known to affect the diagnostic efficiency of this instrument. The HRT MRA performed better than most physicians and was consistent with the glaucoma experts. These results suggest that MRA can be a valuable tool for diagnosing glaucoma in ordinary practice, particularly when only a few glaucoma experts are available. Even though MRA provided 100% sensitivity in eyes with advanced glaucoma, it probably does not offer sufficient specificity to make it suitable as a screening method. Continuing medical education on ONH analysis had a small, but positive effect on diagnostic accuracy for glaucoma. An ANN trained to classify visual fields seemed to perform at least as well as most of the participating physicians, whose performances were remarkably similar regardless of their level of experience. This indicates that available tools for interpreting SAP findings are helpful in assessments of visual field test results. However, SAP is associated with learning effects (Heijl et al. 1989) that may entail low specificity for untrained subjects, and hence, it is not an ideal screening method for glaucoma. By comparison, the screening test of FDT is rapid and easy, but it is probably less suitable for screening purpose, because some eyes with advanced glaucoma were missed in this investigation. GDx VCC images for a relatively large number of eyes could not be analysed and is thus not appropriate for screening. The OCT instruments offer both high sensitivity and high specificity, and all eyes with advanced disease were correctly classified as glaucomatous in this evaluation. However, these instruments are still expensive and require special operator skills. Additional development to obtain OCT instrument that is more compact, easier to use and less expensive might render such tomography suitable as a screening tool for glaucoma. © 2013 The Author. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.
Optimising the laboratory supply chain: The key to effective laboratory services
Williams, Jason; Smith, Peter; Kuritsky, Joel
2014-01-01
Background The Supply Chain Management System (SCMS) is a contract managed under the Partnership for Supply Chain Management (PFSCM) consortium by the United States Agency for International Development (USAID). SCMS procures commodities for programmes supported by the US President’s Emergency Plan for AIDS Relief (PEPFAR). From 2005 to mid-2012, PEPFAR, through SCMS, spent approximately $384 million on non-pharmaceutical commodities. Of this, an estimated $90m was used to purchase flow cytometry technology, largely for flow cytometry platforms and reagents. Objectives The purpose of this paper is to highlight the cost differences between low, medium and high utilisation rates of common CD4 testing instruments that have been procured though PEPFAR funding. Method A scale of costs per test as a function of test volume through the machine was calculated for the two most common CD4 testing machines used in HIV programmes: Becton Dickinson (BD) FACSCount™ and BD FACSCalibur™. Instrument utilisation data collected at the facility level in three selected countries were then used to calculate the onsite cost-per-test experienced in each country. Results Cost analyses indicated that a target of at least 40% utilisation for FACSCount™ and 15% utilisation for FACSCalibur™, respectively, closely approach maximal per-test cost efficiency. The average utilisation rate for CD4 testing instruments varies widely by country, level of laboratory and partner (0% − 68%). Conclusion Our analysis indicates that, because cost-per-test is related inversely to sample throughput, the underutilisation of flow cytometry machines is resulting in an increase in average cost-per-test for many instruments. PMID:29043175
An electric stimulation system for electrokinetic particle manipulation in microfluidic devices.
Lopez-de la Fuente, M S; Moncada-Hernandez, H; Perez-Gonzalez, V H; Lapizco-Encinas, B H; Martinez-Chapa, S O
2013-03-01
Microfluidic devices have grown significantly in the number of applications. Microfabrication techniques have evolved considerably; however, electric stimulation systems for microdevices have not advanced at the same pace. Electric stimulation of micro-fluidic devices is an important element in particle manipulation research. A flexible stimulation instrument is desired to perform configurable, repeatable, automated, and reliable experiments by allowing users to select the stimulation parameters. The instrument presented here is a configurable and programmable stimulation system for electrokinetic-driven microfluidic devices; it consists of a processor, a memory system, and a user interface to deliver several types of waveforms and stimulation patterns. It has been designed to be a flexible, highly configurable, low power instrument capable of delivering sine, triangle, and sawtooth waveforms with one single frequency or two superimposed frequencies ranging from 0.01 Hz to 40 kHz, and an output voltage of up to 30 Vpp. A specific stimulation pattern can be delivered over a single time period or as a sequence of different signals for different time periods. This stimulation system can be applied as a research tool where manipulation of particles suspended in liquid media is involved, such as biology, medicine, environment, embryology, and genetics. This system has the potential to lead to new schemes for laboratory procedures by allowing application specific and user defined electric stimulation. The development of this device is a step towards portable and programmable instrumentation for electric stimulation on electrokinetic-based microfluidic devices, which are meant to be integrated with lab-on-a-chip devices.