The Promise of Zoomable User Interfaces
ERIC Educational Resources Information Center
Bederson, Benjamin B.
2011-01-01
Zoomable user interfaces (ZUIs) have received a significant amount of attention in the 18 years since they were introduced. They have enjoyed some success, and elements of ZUIs are widely used in computers today, although the grand vision of a zoomable desktop has not materialised. This paper describes the premise and promise of ZUIs along with…
Mimoza: web-based semantic zooming and navigation in metabolic networks.
Zhukova, Anna; Sherman, David J
2015-02-26
The complexity of genome-scale metabolic models makes them quite difficult for human users to read, since they contain thousands of reactions that must be included for accurate computer simulation. Interestingly, hidden similarities between groups of reactions can be discovered, and generalized to reveal higher-level patterns. The web-based navigation system Mimoza allows a human expert to explore metabolic network models in a semantically zoomable manner: The most general view represents the compartments of the model; the next view shows the generalized versions of reactions and metabolites in each compartment; and the most detailed view represents the initial network with the generalization-based layout (where similar metabolites and reactions are placed next to each other). It allows a human expert to grasp the general structure of the network and analyze it in a top-down manner Mimoza can be installed standalone, or used on-line at http://mimoza.bordeaux.inria.fr/ , or installed in a Galaxy server for use in workflows. Mimoza views can be embedded in web pages, or downloaded as COMBINE archives.
Digital Projectors Demystified
ERIC Educational Resources Information Center
Careless, James
2007-01-01
Digital projectors are becoming a common sight in U.S. schools. A projector can serve many roles, from letting teachers give tours of educational Web sites to having students present their projects to the entire class. With this trend come questions: Which projection technology is the most cost-effective? Which requires the least maintenance? How…
WEBSLIDE: A "Virtual" Slide Projector Based on World Wide Web.
ERIC Educational Resources Information Center
Barra, Maria; Ferrandino, Salvatore; Scarano, Vittorio
1999-01-01
Presents the key design concepts of a software project whose objective is to provide a simple, cheap, and efficient solution for showing slides during lessons in computer labs. Contains 26 references. (DDR)
Seamless presentation capture, indexing, and management
NASA Astrophysics Data System (ADS)
Hilbert, David M.; Cooper, Matthew; Denoue, Laurent; Adcock, John; Billsus, Daniel
2005-10-01
Technology abounds for capturing presentations. However, no simple solution exists that is completely automatic. ProjectorBox is a "zero user interaction" appliance that automatically captures, indexes, and manages presentation multimedia. It operates continuously to record the RGB information sent from presentation devices, such as a presenter's laptop, to display devices, such as a projector. It seamlessly captures high-resolution slide images, text and audio. It requires no operator, specialized software, or changes to current presentation practice. Automatic media analysis is used to detect presentation content and segment presentations. The analysis substantially enhances the web-based user interface for browsing, searching, and exporting captured presentations. ProjectorBox has been in use for over a year in our corporate conference room, and has been deployed in two universities. Our goal is to develop automatic capture services that address both corporate and educational needs.
NASA Astrophysics Data System (ADS)
Herwig, C.
2017-12-01
The Landsat program offers an unparalleled record of our changing planet, with satellites that have been observing the Earth since 1972 to the present day. However, clouds, seasonal variation, and technical challenges around access to large volumes of data make it difficult for researchers and the public to understand global and regional scale changes across time through the planetary dataset. Earth Timelapse is a global, zoomable video that has helped revolutionize how users - millions of which have never been capable of utilizing Landsat data before - monitor and understand a changing planet. It is made from 33 cloud-free annual mosaics, one for each year from 1984 to 2016, which are made interactively explorable by Carnegie Mellon University CREATE Lab's Time Machine library, a technology for creating and viewing zoomable and pannable timelapses over space and time. Using Earth Engine, we combined over 5 million satellite images acquired over the past three decades by 5 different satellites. The majority of the images come from Landsat, a joint USGS/NASA Earth observation program that has observed the Earth since the 1970s. For 2015 and 2016, we combined Landsat 8 imagery with imagery from Sentinel-2A, part of the European Commission and European Space Agency's Copernicus Earth observation program. Along with the interactive desktop Timelapse application, we created a 200-video YouTube playlist highlighting areas across the world exhibiting change in the dataset.Earth Timelapse is an example that illustrates the power of Google Earth Engine's cloud-computing platform, which enables users such as scientists, researchers, and journalists to detect changes, map trends, and quantify differences on the Earth's surface using Google's computational infrastructure and the multi-petabyte Earth Engine data catalog. Earth Timelapse also highlights the value of data visualization to communicate with non-scientific audiences with varied technical and internet connectivity. Timelapse videos - as a global, zoomable and explorable web map across time as well as curated locations hosted on YouTube - can be effective at conveying large and medium scale land surface changes over time to diverse audiences.
NASA Astrophysics Data System (ADS)
Sargent, R.; Egge, M.; Dille, P. S.; O'Donnell, G. D.; Herwig, C.
2016-12-01
Visual evidence ignites curiosity and inspires advocacy. Zoomable imagery and video on a planetary scale provides compelling evidence of human impact on the environment. Earth Timelapse places the observable impact of 30+ years of human activity into the hands of policy makers, scientists, and advocates, with fluidity and speed that supports inquiry and exploration. Zoomability enables compelling narratives and ready apprehension of environmental changes, connecting human-scale evidence to regional and ecosystem-wide trends and changes. Leveraging the power of Google Earth Engine, join us to explore 30+ years of Landset 30m RGB imagery showing glacial retreat, agricultural deforestation, irrigation expansion, and the disappearance of lakes. These narratives are enriched with datasets showing planetary forest gain/loss, annual cycles of agricultural fires, global changes in the health of coral reefs, trends in resource extraction, and of renewable energy development. We demonstrate the intuitive and inquiry-enabling power of these planetary visualizations, and provide instruction on how scientists and advocates can create and share or contribute visualizations of their own research or topics of interest.
Hybrid wavefront sensing and image correction algorithm for imaging through turbulent media
NASA Astrophysics Data System (ADS)
Wu, Chensheng; Robertson Rzasa, John; Ko, Jonathan; Davis, Christopher C.
2017-09-01
It is well known that passive image correction of turbulence distortions often involves using geometry-dependent deconvolution algorithms. On the other hand, active imaging techniques using adaptive optic correction should use the distorted wavefront information for guidance. Our work shows that a hybrid hardware-software approach is possible to obtain accurate and highly detailed images through turbulent media. The processing algorithm also takes much fewer iteration steps in comparison with conventional image processing algorithms. In our proposed approach, a plenoptic sensor is used as a wavefront sensor to guide post-stage image correction on a high-definition zoomable camera. Conversely, we show that given the ground truth of the highly detailed image and the plenoptic imaging result, we can generate an accurate prediction of the blurred image on a traditional zoomable camera. Similarly, the ground truth combined with the blurred image from the zoomable camera would provide the wavefront conditions. In application, our hybrid approach can be used as an effective way to conduct object recognition in a turbulent environment where the target has been significantly distorted or is even unrecognizable.
Data visualization in interactive maps and time series
NASA Astrophysics Data System (ADS)
Maigne, Vanessa; Evano, Pascal; Brockmann, Patrick; Peylin, Philippe; Ciais, Philippe
2014-05-01
State-of-the-art data visualization has nothing to do with plots and maps we used few years ago. Many opensource tools are now available to provide access to scientific data and implement accessible, interactive, and flexible web applications. Here we will present a web site opened November 2013 to create custom global and regional maps and time series from research models and datasets. For maps, we explore and get access to data sources from a THREDDS Data Server (TDS) with the OGC WMS protocol (using the ncWMS implementation) then create interactive maps with the OpenLayers javascript library and extra information layers from a GeoServer. Maps become dynamic, zoomable, synchroneaously connected to each other, and exportable to Google Earth. For time series, we extract data from a TDS with the Netcdf Subset Service (NCSS) then display interactive graphs with a custom library based on the Data Driven Documents javascript library (D3.js). This time series application provides dynamic functionalities such as interpolation, interactive zoom on different axes, display of point values, and export to different formats. These tools were implemented for the Global Carbon Atlas (http://www.globalcarbonatlas.org): a web portal to explore, visualize, and interpret global and regional carbon fluxes from various model simulations arising from both human activities and natural processes, a work led by the Global Carbon Project.
NASA Astrophysics Data System (ADS)
Feng, Zhixin
2018-02-01
Projector calibration is crucial for a camera-projector three-dimensional (3-D) structured light measurement system, which has one camera and one projector. In this paper, a novel projector calibration method is proposed based on digital image correlation. In the method, the projector is viewed as an inverse camera, and a plane calibration board with feature points is used to calibrate the projector. During the calibration processing, a random speckle pattern is projected onto the calibration board with different orientations to establish the correspondences between projector images and camera images. Thereby, dataset for projector calibration are generated. Then the projector can be calibrated using a well-established camera calibration algorithm. The experiment results confirm that the proposed method is accurate and reliable for projector calibration.
The Full Monty: Locating Resources, Creating, and Presenting a Web Enhanced History Course.
ERIC Educational Resources Information Center
Bazillion, Richard J.; Braun, Connie L.
2001-01-01
Discusses how to develop a history course using the World Wide Web; course development software; full text digitized articles, electronic books, primary documents, images, and audio files; and computer equipment such as LCD projectors and interactive whiteboards. Addresses the importance of support for faculty using technology in teaching. (PAL)
WEBSLIDE: A "Virtual" Slide Projector Based on World Wide Web
NASA Astrophysics Data System (ADS)
Barra, Maria; Ferrandino, Salvatore; Scarano, Vittorio
1999-03-01
We present here the design key concepts of WEBSLIDE, a software project whose objective is to provide a simple, cheap and efficient solution for showing slides during lessons in computer labs. In fact, WEBSLIDE allows the video monitors of several client machines (the "STUDENTS") to be synchronously updated by the actions of a particular client machine, called the "INSTRUCTOR." The system is based on the World Wide Web and the software components of WEBSLIDE mainly consists in a WWW server, browsers and small Cgi-Bill scripts. What makes WEBSLIDE particularly appealing for small educational institutions is that WEBSLIDE is built with "off the shelf" products: it does not involve using a specifically designed program but any Netscape browser, one of the most popular browsers available on the market, is sufficient. Another possible use is to use our system to implement "guided automatic tours" through several pages or Intranets internal news bulletins: the company Web server can broadcast to all employees relevant information on their browser.
NASA Astrophysics Data System (ADS)
Qin, Chen; Ren, Bin; Guo, Longfei; Dou, Wenhua
2014-11-01
Multi-projector three dimension display is a promising multi-view glass-free three dimension (3D) display technology, can produce full colour high definition 3D images on its screen. One key problem of multi-projector 3D display is how to acquire the source images of projector array while avoiding pseudoscopic problem. This paper analysis the displaying characteristics of multi-projector 3D display first and then propose a projector content synthetic method using tetrahedral transform. A 3D video format that based on stereo image pair and associated disparity map is presented, it is well suit for any type of multi-projector 3D display and has advantage in saving storage usage. Experiment results show that our method solved the pseudoscopic problem.
The Role of the Modern Planetarium as an Effective Tool in Astronomy Education and Public Outreach
NASA Astrophysics Data System (ADS)
Albin, Edward F.
2016-01-01
As the planetarium approaches its 100th anniversary, today's planetarium educator must reflect on the role of such technology in contemporary astronomy education and outreach. The projection planetarium saw "first light" in 1923 at the Carl Zeiss factory in Jena, Germany. During the 20th century, the concept of a star projector beneath a dome flourished as an extraordinary device for the teaching of astronomy. The evolution of digital technology over the past twenty years has dramatically changed the perception / utilization of the planetarium. The vast majority of modern star theaters have shifted entirely to fulldome digital projection systems, abandoning the once ubiquitous electromechanical star projector altogether. These systems have evolved into ultra-high resolution theaters, capable of projecting imagery, videos, and any web-based media onto the dome. Such capability has rendered the planetarium as a multi-disciplinary tool, broadening its educational appeal to a wide variety of fields -- including life sciences, the humanities, and even entertainment venues. However, we suggest that what is at the heart of the planetarium appeal is having a theater adept at projecting a beautiful / accurate star-field. To this end, our facility chose to keep / maintain its aging Zeiss V star projector while adding fulldome digital capability. Such a hybrid approach provides an excellent compromise between presenting state of the art multimedia while at the same time maintaining the ability to render a stunning night sky. In addition, our facility maintains two portable StarLab planetariums for outreach purposes, one unit with a classic electromechanical star projector and the other having a relatively inexpensive fulldome projection system. With a combination of these technologies, it is possible for the planetarium to be an effective tool for astronomical education / outreach well into the 21st century.
Media Specialists Can Learn Web 2.0 Tools to Make Schools More Cool
ERIC Educational Resources Information Center
Hauser, Judy
2007-01-01
Media specialists today are required to use more and more technology. Their responsibilities encompass everything from repairing overhead projectors to administrating an entire library's automated system. These responsibilities are in addition to working with students on research and information literacy, making book selections, and collaborating…
Waese, Jamie; Fan, Jim; Yu, Hans; Fucile, Geoffrey; Shi, Ruian; Cumming, Matthew; Town, Chris; Stuerzlinger, Wolfgang
2017-01-01
A big challenge in current systems biology research arises when different types of data must be accessed from separate sources and visualized using separate tools. The high cognitive load required to navigate such a workflow is detrimental to hypothesis generation. Accordingly, there is a need for a robust research platform that incorporates all data and provides integrated search, analysis, and visualization features through a single portal. Here, we present ePlant (http://bar.utoronto.ca/eplant), a visual analytic tool for exploring multiple levels of Arabidopsis thaliana data through a zoomable user interface. ePlant connects to several publicly available web services to download genome, proteome, interactome, transcriptome, and 3D molecular structure data for one or more genes or gene products of interest. Data are displayed with a set of visualization tools that are presented using a conceptual hierarchy from big to small, and many of the tools combine information from more than one data type. We describe the development of ePlant in this article and present several examples illustrating its integrative features for hypothesis generation. We also describe the process of deploying ePlant as an “app” on Araport. Building on readily available web services, the code for ePlant is freely available for any other biological species research. PMID:28808136
A simple and low-cost structured illumination microscopy using a pico-projector
NASA Astrophysics Data System (ADS)
Özgürün, Baturay
2018-02-01
Here, development of a low-cost structured illumination microscopy (SIM) based on a pico-projector is presented. The pico-projector consists of independent red, green and blue LEDs that remove need for an external illumination source. Moreover, display element of the pico-projector serves as a pattern generating spatial light modulator. A simple lens group is employed to couple light from the projector to an epi-illumination port of a commercial microscope system. 2D sub SIM images are acquired and synthesized to surpass the diffraction limit using 40x (0.75 NA) objective. Resolution of the reconstructed SIM images is verified with a dye-and-object object and a fixed cell sample.
Zhang, Jiarui; Zhang, Yingjie; Chen, Bo
2017-12-20
The three-dimensional measurement system with a binary defocusing technique is widely applied in diverse fields. The measurement accuracy is mainly determined by out-of-focus projector calibration accuracy. In this paper, a high-precision out-of-focus projector calibration method that is based on distortion correction on the projection plane and nonlinear optimization algorithm is proposed. To this end, the paper experimentally presents the principle that the projector has noticeable distortions outside its focus plane. In terms of this principle, the proposed method uses a high-order radial and tangential lens distortion representation on the projection plane to correct the calibration residuals caused by projection distortion. The final accuracy parameters of out-of-focus projector were obtained using a nonlinear optimization algorithm with good initial values, which were provided by coarsely calibrating the parameters of the out-of-focus projector on the focal and projection planes. Finally, the experimental results demonstrated that the proposed method can accuracy calibrate an out-of-focus projector, regardless of the amount of defocusing.
NASA Astrophysics Data System (ADS)
Havens, John R.; Ishioka, J.; Jones, Philip J.; Lau, Aldrich; Tomita, Akira; Asano, A.; Konuma, Nobuhiro; Sato, Kazuhiko; Takemoto, Iwao
1997-05-01
Projectors based on polymer-eNCAPsulated liquid crystals can provide bright displays suitable for use in conference rooms with normal lighting. Contrast is generated by light scattering among the droplets, rather than by light absorption with crossed polarizers. We have demonstrated a full-color, compact projector showing 1200 ANSI lumens with 200 watts of lamp power - a light efficiency of 6 lumens/watt. This projector is based on low-voltage NCAP material, highly reflective CMOS die, and matched illumination and projection optics. We will review each of these areas and discuss the integrated system performance.
Freeware eLearning Flash-ECG for learning electrocardiography.
Romanov, Kalle; Kuusi, Timo
2009-06-01
Electrocardiographic (ECG) analysis can be taught in eLearning programmes with suitable software that permits the effective use of basic tools such as a ruler and a magnifier, required for measurements. The Flash-ECG (Research & Development Unit for Medical Education, University of Helsinki, Finland) was developed to enable teachers and students to use scanned and archived ECGs on computer screens and classroom projectors. The software requires only a standard web browser with a Flash plug-in and can be integrated with learning environments (Blackboard/WebCT, Moodle). The Flash-ECG is freeware and is available to medical teachers worldwide.
Waese, Jamie; Fan, Jim; Pasha, Asher; Yu, Hans; Fucile, Geoffrey; Shi, Ruian; Cumming, Matthew; Kelley, Lawrence A; Sternberg, Michael J; Krishnakumar, Vivek; Ferlanti, Erik; Miller, Jason; Town, Chris; Stuerzlinger, Wolfgang; Provart, Nicholas J
2017-08-01
A big challenge in current systems biology research arises when different types of data must be accessed from separate sources and visualized using separate tools. The high cognitive load required to navigate such a workflow is detrimental to hypothesis generation. Accordingly, there is a need for a robust research platform that incorporates all data and provides integrated search, analysis, and visualization features through a single portal. Here, we present ePlant (http://bar.utoronto.ca/eplant), a visual analytic tool for exploring multiple levels of Arabidopsis thaliana data through a zoomable user interface. ePlant connects to several publicly available web services to download genome, proteome, interactome, transcriptome, and 3D molecular structure data for one or more genes or gene products of interest. Data are displayed with a set of visualization tools that are presented using a conceptual hierarchy from big to small, and many of the tools combine information from more than one data type. We describe the development of ePlant in this article and present several examples illustrating its integrative features for hypothesis generation. We also describe the process of deploying ePlant as an "app" on Araport. Building on readily available web services, the code for ePlant is freely available for any other biological species research. © 2017 American Society of Plant Biologists. All rights reserved.
Durfee, Sara M; Jain, Sidney; Shaffer, Kitt
2003-02-01
The purpose of this study was to define the current use of information technology in radiology tutorials for medical students. The authors conducted a Web-based survey of directors of medical school courses in radiology. The survey dealt with the details of the courses and the use of computers and the Web during the courses. There were 48 responses. Most radiology courses were elective (73%) and were offered monthly. Most institutions (79%) had picture archiving and communication systems (PACS) available or were completely filmless. The teaching case presentations, however, often included film images displayed on a view box or by an overhead projector. Computers dedicated to student use were uncommon (28%). The Web was used infrequently as a teaching resource, and a Web site was not available in most courses. Computer technical support was variable and usually provided by the course director. Course directors at institutions with PACS were more likely to use digital technology for case presentations and more likely to use the Web for teaching purposes. Despite the widespread use of digital technology and PACS in the field of radiology, digital technology is underused in radiology courses. However, departments with PACS tend to use digital technology more frequently in education than do departments without PACS.
BRDF-dependent accuracy of array-projection-based 3D sensors.
Heist, Stefan; Kühmstedt, Peter; Tünnermann, Andreas; Notni, Gunther
2017-03-10
In order to perform high-speed three-dimensional (3D) shape measurements with structured light systems, high-speed projectors are required. One possibility is an array projector, which allows pattern projection at several tens of kilohertz by switching on and off the LEDs of various slide projectors. The different projection centers require a separate analysis, as the intensity received by the cameras depends on the projection direction and the object's bidirectional reflectance distribution function (BRDF). In this contribution, we investigate the BRDF-dependent errors of array-projection-based 3D sensors and propose an error compensation process.
Mutually unbiased projectors and duality between lines and bases in finite quantum systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shalaby, M.; Vourdas, A., E-mail: a.vourdas@bradford.ac.uk
2013-10-15
Quantum systems with variables in the ring Z(d) are considered, and the concepts of weak mutually unbiased bases and mutually unbiased projectors are discussed. The lines through the origin in the Z(d)×Z(d) phase space, are classified into maximal lines (sets of d points), and sublines (sets of d{sub i} points where d{sub i}|d). The sublines are intersections of maximal lines. It is shown that there exists a duality between the properties of lines (resp., sublines), and the properties of weak mutually unbiased bases (resp., mutually unbiased projectors). -- Highlights: •Lines in discrete phase space. •Bases in finite quantum systems. •Dualitymore » between bases and lines. •Weak mutually unbiased bases.« less
Anderson, Hazel P; Ward, Jamie
2015-05-01
Questionnaires have been developed for categorising grapheme-colour synaesthetes into two sub-types based on phenomenology: associators and projectors. The general approach has been to assume a priori the existence of two sub-types on a single dimension (with endpoints as projector and associator) rather than explore, in a data-driven fashion, other possible models. We collected responses from 175 grapheme-colour synaesthetes on two questionnaires, the Illustrated Synaesthetic Experience Questionnaire (Skelton, Ludwig, & Mohr, 2009) and Rouw and Scholte's (2007) Projector-Associator Questionnaire. After Principle Component Analysis both questionnaires were comprised of two factors which coincide with the projector/associator distinction. This suggests that projectors and associators are not opposites of each other, but separate dimensions of experience (e.g. some synaesthetes claim to be both, others claim to be neither). The revised questionnaires provide a useful tool for researchers and insights into the phenomenology of synaesthesia. Copyright © 2015 Elsevier Inc. All rights reserved.
Multi-projector auto-calibration and placement optimization for non-planar surfaces
NASA Astrophysics Data System (ADS)
Li, Dong; Xie, Jinghui; Zhao, Lu; Zhou, Lijing; Weng, Dongdong
2015-10-01
Non-planar projection has been widely applied in virtual reality and digital entertainment and exhibitions because of its flexible layout and immersive display effects. Compared with planar projection, a non-planar projection is more difficult to achieve because projector calibration and image distortion correction are difficult processes. This paper uses a cylindrical screen as an example to present a new method for automatically calibrating a multi-projector system in a non-planar environment without using 3D reconstruction. This method corrects the geometric calibration error caused by the screen's manufactured imperfections, such as an undulating surface or a slant in the vertical plane. In addition, based on actual projection demand, this paper presents the overall performance evaluation criteria for the multi-projector system. According to these criteria, we determined the optimal placement for the projectors. This method also extends to surfaces that can be parameterized, such as spheres, ellipsoids, and paraboloids, and demonstrates a broad applicability.
Augmented reality 3D display using head-mounted projectors and transparent retro-reflective screen
NASA Astrophysics Data System (ADS)
Soomro, Shoaib R.; Urey, Hakan
2017-02-01
A 3D augmented reality display is proposed that can provide glass-free stereo parallax using a highly transparent projection screen. The proposed display is based on a transparent retro-reflective screen and a pair of laser pico projectors placed close to the viewer's head. The retro-reflective screen directs incident light towards its source with little scattering so that each of the viewer's eyes only perceives the content projected by the associated projector. Each projector displays one of the two components (left or right channel) of stereo content. The retro-reflective nature of screen provides high brightness compared to the regular diffused screens. The partially patterned retro-reflective material on clear substrate introduces optical transparency and facilitates the viewer to see the real-world scene on the other side of screen. The working principle and design of the proposed see-through 3D display are presented. A tabletop prototype consisting of an in-house fabricated 60×40cm2 see-through retro-reflective screen and a pair of 30 lumen pico-projectors with custom 3D printed housings is demonstrated. Geometric calibration between projectors and optimal viewing conditions (eye box size, eye-to-projector distance) are discussed. The display performance is evaluated by measuring the brightness and crosstalk for each eye. The screen provides high brightness (up to 300 cd/m2 per eye) using 30 lumens mobile projectors while maintaining the 75% screen transparency. The crosstalk between left and right views is measured as <10% at the optimum distance of 125-175 cm, which is within acceptable range.
Orthogonal polynomial projectors for the Projector Augmented Wave (PAW) formalism.
NASA Astrophysics Data System (ADS)
Holzwarth, N. A. W.; Matthews, G. E.; Tackett, A. R.; Dunning, R. B.
1998-03-01
The PAW method for density functional electronic structure calculations developed by Blöchl(Phys. Rev. B 50), 17953 (1994) and also used by our group(Phys. Rev. B 55), 2005 (1997) has numerical advantages of a pseudopotential technique while retaining the physics of an all-electron formalism. We describe a new method for generating the necessary set of atom-centered projector and basis functions, based on choosing the projector functions from a set of orthogonal polynomials multiplied by a localizing weight factor. Numerical benefits of the new scheme result from having direct control of the shape of the projector functions and from the use of a simple repulsive local potential term to eliminate ``ghost state" problems, which can haunt calculations of this kind. We demonstrate the method by calculating the cohesive energies of CaF2 and Mo and the density of states of CaMoO4 which shows detailed agreement with LAPW results over a 66 eV range of energy including upper core, valence, and conduction band states.
Non-moving Hadamard matrix diffusers for speckle reduction in laser pico-projectors
NASA Astrophysics Data System (ADS)
Thomas, Weston; Middlebrook, Christopher
2014-12-01
Personal electronic devices such as cell phones and tablets continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. This paper presents a binary diffuser known as a Hadamard matrix diffuser. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values measured showing good agreement with theory and simulated values.
Sakai, Seiichiro; Ueno, Kenichi; Ishizuka, Toru; Yawo, Hiromu
2013-01-01
Optical manipulation technologies greatly advanced the understanding of the neuronal network and its dysfunctions. To achieve patterned and parallel optical switching, we developed a microscopic illumination system using a commercial DMD-based projector and a software program. The spatiotemporal patterning of the system was evaluated using acute slices of the hippocampus. The neural activity was optically manipulated, positively by the combination of channelrhodopsin-2 (ChR2) and blue light, and negatively by the combination of archaerhodopsin-T (ArchT) and green light. It is suggested that our projector-managing optical system (PMOS) would effectively facilitate the optogenetic analyses of neurons and their circuits. Copyright © 2012 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
Scalable large format 3D displays
NASA Astrophysics Data System (ADS)
Chang, Nelson L.; Damera-Venkata, Niranjan
2010-02-01
We present a general framework for the modeling and optimization of scalable large format 3-D displays using multiple projectors. Based on this framework, we derive algorithms that can robustly optimize the visual quality of an arbitrary combination of projectors (e.g. tiled, superimposed, combinations of the two) without manual adjustment. The framework creates for the first time a new unified paradigm that is agnostic to a particular configuration of projectors yet robustly optimizes for the brightness, contrast, and resolution of that configuration. In addition, we demonstrate that our algorithms support high resolution stereoscopic video at real-time interactive frame rates achieved on commodity graphics hardware. Through complementary polarization, the framework creates high quality multi-projector 3-D displays at low hardware and operational cost for a variety of applications including digital cinema, visualization, and command-and-control walls.
Personal projection with Ujoy technology
NASA Astrophysics Data System (ADS)
Moench, Holger; Mackens, Uwe; Pekarski, Pavel; Ritz, Arnd; S'heeren, Griet; Verbeek, Will
2007-02-01
Personal projection is a new way to use projectors for gaming, entertainment or photo projection. The requirements for this new category have been defined based on market research with focus groups. A screen brightness of 200-300lm out of compact and affordable devices is a must. In order to reach this performance a very bright light source is at least as important as for professional projectors. The new 50W Ujoy lamp system with 1mm arc enables efficient projection systems. Lower cooling requirements, the potential for battery operation and the low voltage input makes it the ideal source for this new category of projectors.
Zheng, Jiabei; Fessler, Jeffrey A; Chan, Heang-Ping
2017-01-01
Purpose Digital forward and back projectors play a significant role in iterative image reconstruction. The accuracy of the projector affects the quality of the reconstructed images. Digital breast tomosynthesis (DBT) often uses the ray-tracing (RT) projector that ignores finite detector element size. This paper proposes a modified version of the separable footprint (SF) projector, called the segmented separable footprint (SG) projector, that calculates efficiently the Radon transform mean value over each detector element. The SG projector is specifically designed for DBT reconstruction because of the large height-to-width ratio of the voxels generally used in DBT. This study evaluates the effectiveness of the SG projector in reducing projection error and improving DBT reconstruction quality. Methods We quantitatively compared the projection error of the RT and the SG projector at different locations and their performance in regular and subpixel DBT reconstruction. Subpixel reconstructions used finer voxels in the imaged volume than the detector pixel size. Subpixel reconstruction with RT projector uses interpolated projection views as input to provide adequate coverage of the finer voxel grid with the traced rays. Subpixel reconstruction with the SG projector, however, uses the measured projection views without interpolation. We simulated DBT projections of a test phantom using CatSim (GE Global Research, Niskayuna, NY) under idealized imaging conditions without noise and blur, to analyze the effects of the projectors and subpixel reconstruction without other image degrading factors. The phantom contained an array of horizontal and vertical line pair patterns (1 to 9.5 line pairs/mm) and pairs of closely spaced spheres (diameters 0.053 to 0.5 mm) embedded at the mid-plane of a 5-cm-thick breast-tissue-equivalent uniform volume. The images were reconstructed with regular simultaneous algebraic reconstruction technique (SART) and subpixel SART using different projectors. The resolution and contrast of the test objects in the reconstructed images and the computation times were compared under different reconstruction conditions. Results The SG projector reduced the projector error by 1 to 2 orders of magnitude at most locations. In the worst case, the SG projector still reduced the projection error by about 50%. In the DBT reconstructed slices parallel to the detector plane, the SG projector not only increased the contrast of the line pairs and spheres, but also produced more smooth and continuous reconstructed images whereas the discrete and sparse nature of the RT projector caused artifacts appearing as patterned noise. For subpixel reconstruction, the SG projector significantly increased object contrast and computation speed, especially for high subpixel ratios, compared with the RT projector implemented with accelerated Siddon’s algorithm. The difference in the depth resolution among the projectors is negligible under the conditions studied. Our results also demonstrated that subpixel reconstruction can improve the spatial resolution of the reconstructed images, and can exceed the Nyquist limit of the detector under some conditions. Conclusions The SG projector was more accurate and faster than the RT projector. The SG projector also substantially reduced computation time and improved the image quality for the tomosynthesized images with and without subpixel reconstruction. PMID:28058719
A Volumetric Flask as a Projector
ERIC Educational Resources Information Center
Limsuwan, P.; Asanithi, P.; Thongpool, V.; Piriyawong, V.; Limsuwan, S.
2012-01-01
A lens based on liquid in the confined volume of a volumetric flask was presented as a potential projector to observe microscopic floating organisms or materials. In this experiment, a mosquito larva from a natural pond was selected as a demonstration sample. By shining a light beam from a laser pointer of any visible wavelength through the…
Lemaire, Edward; Greene, G
2003-01-01
We produced continuing education material in physical rehabilitation using a variety of electronic media. We compared four methods of delivering the learning modules: in person with a computer projector, desktop videoconferencing, Web pages and CD-ROM. Health-care workers at eight community hospitals and two nursing homes were asked to participate in the project. A total of 394 questionnaires were received for all modalities: 73 for in-person sessions, 50 for desktop conferencing, 227 for Web pages and 44 for CD-ROM. This represents a 100% response rate from the in-person, desktop conferencing and CD-ROM groups; the response rate for the Web group is unknown, since the questionnaires were completed online. Almost all participants found the modules to be helpful in their work. The CD-ROM group gave significantly higher ratings than the Web page group, although all four learning modalities received high ratings. A combination of all four modalities would be required to provide the best possible learning opportunity.
Design of a single projector multiview 3D display system
NASA Astrophysics Data System (ADS)
Geng, Jason
2014-03-01
Multiview three-dimensional (3D) display is able to provide horizontal parallax to viewers with high-resolution and fullcolor images being presented to each view. Most multiview 3D display systems are designed and implemented using multiple projectors, each generating images for one view. Although this multi-projector design strategy is conceptually straightforward, implementation of such multi-projector design often leads to a very expensive system and complicated calibration procedures. Even for a multiview system with a moderate number of projectors (e.g., 32 or 64 projectors), the cost of a multi-projector 3D display system may become prohibitive due to the cost and complexity of integrating multiple projectors. In this article, we describe an optical design technique for a class of multiview 3D display systems that use only a single projector. In this single projector multiview (SPM) system design, multiple views for the 3D display are generated in a time-multiplex fashion by the single high speed projector with specially designed optical components, a scanning mirror, and a reflective mirror array. Images of all views are generated sequentially and projected via the specially design optical system from different viewing directions towards a 3D display screen. Therefore, the single projector is able to generate equivalent number of multiview images from multiple viewing directions, thus fulfilling the tasks of multiple projectors. An obvious advantage of the proposed SPM technique is the significant reduction of cost, size, and complexity, especially when the number of views is high. The SPM strategy also alleviates the time-consuming procedures for multi-projector calibration. The design method is flexible and scalable and can accommodate systems with different number of views.
Modular design of the LED vehicle projector headlamp system.
Hsieh, Chi-Chang; Li, Yan-Huei; Hung, Chih-Ching
2013-07-20
A well designed headlamp for a vehicle lighting system is very important as it provides drivers with safe and comfortable driving conditions at night or in dark places. With the advances of the semiconductor technology, the LED has become the fourth generation lighting source in the auto industry. In this study, we will propose a LED vehicle projector headlamp system. This headlamp system contains several LED headlamp modules, and every module of it includes four components: focused LEDs, asymmetric metal-based plates, freeform surfaces, and condenser lenses. By optimizing the number of LED headlamp modules, the proposed LED vehicle projector headlamp system has only five LED headlamp modules. It not only provides the low-beam cutoff without a shield, but also meets the requirements of the ECE R112 regulation. Finally, a prototype of the LED vehicle projector headlamp system was assembled and fabricated to create the correct light pattern.
A closed-loop control-loading system
NASA Technical Reports Server (NTRS)
Ashworth, B. R.; Parrish, R. V.
1979-01-01
Langley Differential Maneuvering Simulator (DMS) realistically simulates two aircraft operating in differential mode. It consists of two identical fixed-base cockpits and dome projection systems. Each projection system consists of sky/Earth projector and target-image generator and projector. Although programmable control forces are small part of overall system, they play large role in providing pilot with kinesthetic cues.
ERIC Educational Resources Information Center
Kirby, Paul J.; And Others
The design, development, test, and evaluation of an electronic hardware device interfacing a commercially available slide projector with a plasma panel computer terminal is reported. The interface device allows an instructional computer program to select slides for viewing based upon the lesson student situation parameters of the instructional…
Bulk silicon as photonic dynamic infrared scene projector
NASA Astrophysics Data System (ADS)
Malyutenko, V. K.; Bogatyrenko, V. V.; Malyutenko, O. Yu.
2013-04-01
A Si-based fast (frame rate >1 kHz), large-scale (scene area 100 cm2), broadband (3-12 μm), dynamic contactless infrared (IR) scene projector is demonstrated. An IR movie appears on a scene because of the conversion of a visible scenario projected at a scene kept at elevated temperature. Light down conversion comes as a result of free carrier generation in a bulk Si scene followed by modulation of its thermal emission output in the spectral band of free carrier absorption. The experimental setup, an IR movie, figures of merit, and the process's advantages in comparison to other projector technologies are discussed.
The compatibility of consumer DLP projectors with time-sequential stereoscopic 3D visualisation
NASA Astrophysics Data System (ADS)
Woods, Andrew J.; Rourke, Tegan
2007-02-01
A range of advertised "Stereo-Ready" DLP projectors are now available in the market which allow high-quality flickerfree stereoscopic 3D visualization using the time-sequential stereoscopic display method. The ability to use a single projector for stereoscopic viewing offers a range of advantages, including extremely good stereoscopic alignment, and in some cases, portability. It has also recently become known that some consumer DLP projectors can be used for timesequential stereoscopic visualization, however it was not well understood which projectors are compatible and incompatible, what display modes (frequency and resolution) are compatible, and what stereoscopic display quality attributes are important. We conducted a study to test a wide range of projectors for stereoscopic compatibility. This paper reports on the testing of 45 consumer DLP projectors of widely different specifications (brand, resolution, brightness, etc). The projectors were tested for stereoscopic compatibility with various video formats (PAL, NTSC, 480P, 576P, and various VGA resolutions) and video input connections (composite, SVideo, component, and VGA). Fifteen projectors were found to work well at up to 85Hz stereo in VGA mode. Twenty three projectors would work at 60Hz stereo in VGA mode.
Scanning laser beam displays based on a 2D MEMS
NASA Astrophysics Data System (ADS)
Niesten, Maarten; Masood, Taha; Miller, Josh; Tauscher, Jason
2010-05-01
The combination of laser light sources and MEMS technology enables a range of display systems such as ultra small projectors for mobile devices, head-up displays for vehicles, wearable near-eye displays and projection systems for 3D imaging. Images are created by scanning red, green and blue lasers horizontally and vertically with a single two-dimensional MEMS. Due to the excellent beam quality of laser beams, the optical designs are efficient and compact. In addition, the laser illumination enables saturated display colors that are desirable for augmented reality applications where a virtual image is used. With this technology, the smallest projector engine for high volume manufacturing to date has been developed. This projector module has a height of 7 mm and a volume of 5 cc. The resolution of this projector is WVGA. No additional projection optics is required, resulting in an infinite focus depth. Unlike with micro-display projection displays, an increase in resolution will not lead to an increase in size or a decrease in efficiency. Therefore future projectors can be developed that combine a higher resolution in an even smaller and thinner form factor with increased efficiencies that will lead to lower power consumption.
Speckle reduction methods in laser-based picture projectors
NASA Astrophysics Data System (ADS)
Akram, M. Nadeem; Chen, Xuyuan
2016-02-01
Laser sources have been promised for many years to be better light sources as compared to traditional lamps or light-emitting diodes (LEDs) for projectors, which enable projectors having wide colour gamut for vivid image, super brightness and high contrast for the best picture quality, long lifetime for maintain free operation, mercury free, and low power consumption for green environment. A major technology obstacle in using lasers for projection has been the speckle noise caused by to the coherent nature of the lasers. For speckle reduction, current state of the art solutions apply moving parts with large physical space demand. Solutions beyond the state of the art need to be developed such as integrated optical components, hybrid MOEMS devices, and active phase modulators for compact speckle reduction. In this article, major methods reported in the literature for the speckle reduction in laser projectors are presented and explained. With the advancement in semiconductor lasers with largely reduced cost for the red, green and the blue primary colours, and the developed methods for their speckle reduction, it is hoped that the lasers will be widely utilized in different projector applications in the near future.
Scorpion Hybrid Optical-based Inertial Tracker (HObIT) test results
NASA Astrophysics Data System (ADS)
Atac, Robert; Spink, Scott; Calloway, Tom; Foxlin, Eric
2014-06-01
High fidelity night-vision training has become important for many of the simulation systems being procured today. The end-users of these simulation-training systems prefer using their actual night-vision goggle (NVG) headsets. This requires that the visual display system stimulate the NVGs in a realistic way. Historically NVG stimulation was done with cathode-ray tube (CRT) projectors. However, this technology became obsolete and in recent years training simulators do NVG stimulation with laser, LCoS and DLP projectors. The LCoS and DLP projection technologies have emerged as the preferred approach for the stimulation of NVGs. Both LCoS and DLP technologies have advantages and disadvantages for stimulating NVGs. LCoS projectors can have more than 5-10 times the contrast capability of DLP projectors. The larger the difference between the projected black level and the brightest object in a scene, the better the NVG stimulation effects can be. This is an advantage of LCoS technology, especially when the proper NVG wavelengths are used. Single-chip DLP projectors, even though they have much reduced contrast compared to LCoS projectors, can use LED illuminators in a sequential red-green-blue fashion to create a projected image. It is straightforward to add an extra infrared (NVG wavelength) LED into this sequential chain of LED illumination. The content of this NVG channel can be independent of the visible scene, which allows effects to be added that can compensate for the lack of contrast inherent in a DLP device. This paper will expand on the differences between LCoS and DLP projectors for stimulating NVGs and summarize the benefits of both in night-vision simulation training systems.
Strategies for Buying and Maintaining Audio Visual Equipment.
ERIC Educational Resources Information Center
Kalmbach, John A.; Kruzel, Richard D.
1989-01-01
Presents guidelines for purchasing and maintaining audiovisual equipment most often used in the classroom. Highlights include selecting a vendor; purchasing associations; preventive maintenance; optical equipment, including overhead projectors, slide projectors, movie projectors, and filmstrip projectors; and electromagnetic equipment, including…
Projector primary-based optimization for superimposed projection mappings
NASA Astrophysics Data System (ADS)
Ahmed, Bilal; Lee, Jong Hun; Lee, Yong Yi; Lee, Kwan H.
2018-01-01
Recently, many researchers have focused on fully overlapping projections for three-dimensional (3-D) projection mapping systems but reproducing a high-quality appearance using this technology still remains a challenge. On top of existing color compensation-based methods, much effort is still required to faithfully reproduce an appearance that is free from artifacts, colorimetric inconsistencies, and inappropriate illuminance over the 3-D projection surface. According to our observation, this is due to the fact that overlapping projections are treated as an additive-linear mixture of color. However, this is not the case according to our elaborated observations. We propose a method that enables us to use high-quality appearance data that are measured from original objects and regenerate the same appearance by projecting optimized images using multiple projectors, ensuring that the projection-rendered results look visually close to the real object. We prepare our target appearances by photographing original objects. Then, using calibrated projector-camera pairs, we compensate for missing geometric correspondences to make our method robust against noise. The heart of our method is a target appearance-driven adaptive sampling of the projection surface followed by a representation of overlapping projections in terms of the projector-primary response. This gives off projector-primary weights to facilitate blending and the system is applied with constraints. These samples are used to populate a light transport-based system. Then, the system is solved minimizing the error to get the projection images in a noise-free manner by utilizing intersample overlaps. We ensure that we make the best utilization of available hardware resources to recreate projection mapped appearances that look as close to the original object as possible. Our experimental results show compelling results in terms of visual similarity and colorimetric error.
A scalable multi-DLP pico-projector system for virtual reality
NASA Astrophysics Data System (ADS)
Teubl, F.; Kurashima, C.; Cabral, M.; Fels, S.; Lopes, R.; Zuffo, M.
2014-03-01
Virtual Reality (VR) environments can offer immersion, interaction and realistic images to users. A VR system is usually expensive and requires special equipment in a complex setup. One approach is to use Commodity-Off-The-Shelf (COTS) desktop multi-projectors manually or camera based calibrated to reduce the cost of VR systems without significant decrease of the visual experience. Additionally, for non-planar screen shapes, special optics such as lenses and mirrors are required thus increasing costs. We propose a low-cost, scalable, flexible and mobile solution that allows building complex VR systems that projects images onto a variety of arbitrary surfaces such as planar, cylindrical and spherical surfaces. This approach combines three key aspects: 1) clusters of DLP-picoprojectors to provide homogeneous and continuous pixel density upon arbitrary surfaces without additional optics; 2) LED lighting technology for energy efficiency and light control; 3) smaller physical footprint for flexibility purposes. Therefore, the proposed system is scalable in terms of pixel density, energy and physical space. To achieve these goals, we developed a multi-projector software library called FastFusion that calibrates all projectors in a uniform image that is presented to viewers. FastFusion uses a camera to automatically calibrate geometric and photometric correction of projected images from ad-hoc positioned projectors, the only requirement is some few pixels overlapping amongst them. We present results with eight Pico-projectors, with 7 lumens (LED) and DLP 0.17 HVGA Chipset.
The Audio-Visual Equipment Directory. Seventeenth Edition.
ERIC Educational Resources Information Center
Herickes, Sally, Ed.
The following types of audiovisual equipment are catalogued: 8 mm. and 16 mm. motion picture projectors, filmstrip and sound filmstrip projectors, slide projectors, random access projection equipment, opaque, overhead, and micro-projectors, record players, special purpose projection equipment, audio tape recorders and players, audio tape…
How to Choose--and Use--Motion Picture Projectors
ERIC Educational Resources Information Center
Training, 1976
1976-01-01
Suggests techniques for selecting super 8 and 16mm movie projectors for various training and communication needs. Charts list various characteristics for 17 models of 8mm projectors with built-in screen, 7 models without screen, and 33 models of 16mm projectors. (WL)
An Accurate Projector Calibration Method Based on Polynomial Distortion Representation
Liu, Miao; Sun, Changku; Huang, Shujun; Zhang, Zonghua
2015-01-01
In structure light measurement systems or 3D printing systems, the errors caused by optical distortion of a digital projector always affect the precision performance and cannot be ignored. Existing methods to calibrate the projection distortion rely on calibration plate and photogrammetry, so the calibration performance is largely affected by the quality of the plate and the imaging system. This paper proposes a new projector calibration approach that makes use of photodiodes to directly detect the light emitted from a digital projector. By analyzing the output sequence of the photoelectric module, the pixel coordinates can be accurately obtained by the curve fitting method. A polynomial distortion representation is employed to reduce the residuals of the traditional distortion representation model. Experimental results and performance evaluation show that the proposed calibration method is able to avoid most of the disadvantages in traditional methods and achieves a higher accuracy. This proposed method is also practically applicable to evaluate the geometric optical performance of other optical projection system. PMID:26492247
Field-Sequential Electronic Stereoscopic Projector
NASA Astrophysics Data System (ADS)
Lipton, Lenny
1989-07-01
Culminating a research and development project spanning many years, StereoGraphics Corporation has succeeded in bringing to market the first field-sequential electronic stereoscopic projector. The product is based on a modification of Electrohome and Barco projectors. Our design goal was to produce a projector capable of displaying an image on a six-foot (or larger) diagonal screen for an audience of 50 or 60 people, or for an individual using a simulator. A second goal was to produce an image that required only passive polarizing glasses rather than powered, tethered visors. Two major design challenges posed themselves. First, it was necessary to create an electro-optical modulator which could switch the characteristic of polarized light at field rate, and second, it was necessary to produce a bright green CRT with short persistence to prevent crosstalk between left and right fields. To solve the first problem, development was undertaken to produce the required electro-optical modulator. The second problem was solved with the help of a vendor specializing in high performance CRT's.
Digital Light Processing update: status and future applications
NASA Astrophysics Data System (ADS)
Hornbeck, Larry J.
1999-05-01
Digital Light Processing (DLP) projection displays based on the Digital Micromirror Device (DMD) were introduced to the market in 1996. Less than 3 years later, DLP-based projectors are found in such diverse applications as mobile, conference room, video wall, home theater, and large-venue. They provide high-quality, seamless, all-digital images that have exceptional stability as well as freedom from both flicker and image lag. Marked improvements have been made in the image quality of DLP-based projection display, including brightness, resolution, contrast ratio, and border image. DLP-based mobile projectors that weighted about 27 pounds in 1996 now weight only about 7 pounds. This weight reduction has been responsible for the definition of an entirely new projector class, the ultraportable. New applications are being developed for this important new projection display technology; these include digital photofinishing for high process speed minilab and maxilab applications and DLP Cinema for the digital delivery of films to audiences around the world. This paper describes the status of DLP-based projection display technology, including its manufacturing, performance improvements, and new applications, with emphasis on DLP Cinema.
When All Else Fails--KICK! Trouble Shooting, Preventive Maintenance, and Auxiliary Equipment.
ERIC Educational Resources Information Center
Beasley, Augie E.; Palmer, Carolyn G.
The guidelines presented in this manual for the maintenance and repair of media equipment and materials provide information on optical systems, slide projectors, film projectors, overhead projectors, record players, cassette recorders, public address systems, opaque projectors, laminators, motion picture films, and cassette tapes. A list of…
Using a Video Projector for Color-Mixing Demonstrations.
ERIC Educational Resources Information Center
Bartels, Richard A.
1982-01-01
Suggestions are provided for using color television projector systems to demonstrate color mixing. With such a projector, manipulation of the three primary colors can be done by simply covering and uncovering the three separate beams. In addition, projector systems serve as good examples in studying geometrical optics. (Author/JN)
Media Manual (How to Use Media Equipment).
ERIC Educational Resources Information Center
Jones, Nancy
Using a workbook format, this guide explains the use of seven types of audiovisual equipment: overhead projector, Bell and Howell 16mm motion picture projector, Dukane filmstrip projector, record player, Kodak slide projector, Wollensak 2552 tape recorder, and JVC videocassette color video system. An introductory section includes (1) a media…
An HTML Tool for Production of Interactive Stereoscopic Compositions.
Chistyakov, Alexey; Soto, Maria Teresa; Martí, Enric; Carrabina, Jordi
2016-12-01
The benefits of stereoscopic vision in medical applications were appreciated and have been thoroughly studied for more than a century. The usage of the stereoscopic displays has a proven positive impact on performance in various medical tasks. At the same time the market of 3D-enabled technologies is blooming. New high resolution stereo cameras, TVs, projectors, monitors, and head mounted displays become available. This equipment, completed with a corresponding application program interface (API), could be relatively easy implemented in a system. Such complexes could open new possibilities for medical applications exploiting the stereoscopic depth. This work proposes a tool for production of interactive stereoscopic graphical user interfaces, which could represent a software layer for web-based medical systems facilitating the stereoscopic effect. Further the tool's operation mode and the results of the conducted subjective and objective performance tests will be exposed.
Visualizing conserved gene location across microbe genomes
NASA Astrophysics Data System (ADS)
Shaw, Chris D.
2009-01-01
This paper introduces an analysis-based zoomable visualization technique for displaying the location of genes across many related species of microbes. The purpose of this visualizatiuon is to enable a biologist to examine the layout of genes in the organism of interest with respect to the gene organization of related organisms. During the genomic annotation process, the ability to observe gene organization in common with previously annotated genomes can help a biologist better confirm the structure and function of newly analyzed microbe DNA sequences. We have developed a visualization and analysis tool that enables the biologist to observe and examine gene organization among genomes, in the context of the primary sequence of interest. This paper describes the visualization and analysis steps, and presents a case study using a number of Rickettsia genomes.
Tiny Devices Project Sharp, Colorful Images
NASA Technical Reports Server (NTRS)
2009-01-01
Displaytech Inc., based in Longmont, Colorado and recently acquired by Micron Technology Inc. of Boise, Idaho, first received a Small Business Innovation Research contract in 1993 from Johnson Space Center to develop tiny, electronic, color displays, called microdisplays. Displaytech has since sold over 20 million microdisplays and was ranked one of the fastest growing technology companies by Deloitte and Touche in 2005. Customers currently incorporate the microdisplays in tiny pico-projectors, which weigh only a few ounces and attach to media players, cell phones, and other devices. The projectors can convert a digital image from the typical postage stamp size into a bright, clear, four-foot projection. The company believes sales of this type of pico-projector may exceed $1.1 billion within 5 years.
Design and test of a simulation system for autonomous optic-navigated planetary landing
NASA Astrophysics Data System (ADS)
Cai, Sheng; Yin, Yanhe; Liu, Yanjun; He, Fengyun
2018-02-01
In this paper, a simulation system based on commercial projector is proposed to test the optical navigation algorithms for autonomous planetary landing in laboratorial scenarios. The design work of optics, mechanics and synchronization control are carried out. Furthermore, the whole simulation system is set up and tested. Through the calibration of the system, two main problems, synchronization between the projector and CCD and pixel-level shifting caused by the low repeatability of DMD used in the projector, are settled. The experimental result shows that the RMS errors of pitch, yaw and roll angles are 0.78', 0.48', and 2.95' compared with the theoretical calculation, which can fulfill the requirement of experimental simulation for planetary landing in laboratory.
Feasibility study of utilizing ultraportable projectors for endoscopic video display (with videos).
Tang, Shou-Jiang; Fehring, Amanda; Mclemore, Mac; Griswold, Michael; Wang, Wanmei; Paine, Elizabeth R; Wu, Ruonan; To, Filip
2014-10-01
Modern endoscopy requires video display. Recent miniaturized, ultraportable projectors are affordable, durable, and offer quality image display. Explore feasibility of using ultraportable projectors in endoscopy. Prospective bench-top comparison; clinical feasibility study. Masked comparison study of images displayed via 2 Samsung ultraportable light-emitting diode projectors (pocket-sized SP-HO3; pico projector SP-P410M) and 1 Microvision Showwx-II Laser pico projector. BENCH-TOP FEASIBILITY STUDY: Prerecorded endoscopic video was streamed via computer. CLINICAL COMPARISON STUDY: Live high-definition endoscopy video was simultaneously displayed through each processor onto a standard liquid crystal display monitor and projected onto a portable, pull-down projection screen. Endoscopists, endoscopy nurses, and technicians rated video images; ratings were analyzed by linear mixed-effects regression models with random intercepts. All projectors were easy to set up, adjust, focus, and operate, with no real-time lapse for any. Bench-top study outcomes: Samsung pico preferred to Laser pico, overall rating 1.5 units higher (95% confidence interval [CI] = 0.7-2.4), P < .001; Samsung pocket preferred to Laser pico, 3.3 units higher (95% CI = 2.4-4.1), P < .001; Samsung pocket preferred to Samsung pico, 1.7 units higher (95% CI = 0.9-2.5), P < .001. The clinical comparison study confirmed the Samsung pocket projector as best, with a higher overall rating of 2.3 units (95% CI = 1.6-3.0), P < .001, than Samsung pico. Low brightness currently limits pico projector use in clinical endoscopy. The pocket projector, with higher brightness levels (170 lumens), is clinically useful. Continued improvements to ultraportable projectors will supply a needed niche in endoscopy through portability, reduced cost, and equal or better image quality. © The Author(s) 2013.
DICOM to print, 35-mm slides, web, and video projector: tutorial using Adobe Photoshop.
Gurney, Jud W
2002-10-01
Preparing images for publication has dealt with film and the photographic process. With picture archiving and communications systems, many departments will no longer produce film. This will change how images are produced for publication. DICOM, the file format for radiographic images, has to be converted and then prepared for traditional publication, 35-mm slides, the newest techniques of video projection, and the World Wide Web. Tagged image file format is the common format for traditional print publication, whereas joint photographic expert group is the current file format for the World Wide Web. Each medium has specific requirements that can be met with a common image-editing program such as Adobe Photoshop (Adobe Systems, San Jose, CA). High-resolution images are required for print, a process that requires interpolation. However, the Internet requires images with a small file size for rapid transmission. The resolution of each output differs and the image resolution must be optimized to match the output of the publishing medium.
Matched-filtering generalized phase contrast using LCoS pico-projectors for beam-forming.
Bañas, Andrew; Palima, Darwin; Glückstad, Jesper
2012-04-23
We report on a new beam-forming system for generating high intensity programmable optical spikes using so-called matched-filtering Generalized Phase Contrast (mGPC) applying two consumer handheld pico-projectors. Such a system presents a low-cost alternative for optical trapping and manipulation, optical lattices and other beam-shaping applications usually implemented with high-end spatial light modulators. Portable pico-projectors based on liquid crystal on silicon (LCoS) devices are used as binary phase-only spatial light modulators by carefully setting the appropriate polarization of the laser illumination. The devices are subsequently placed into the object and Fourier plane of a standard 4f-setup according to the mGPC spatial filtering configuration. Having a reconfigurable spatial phase filter, instead of a fixed and fabricated one, allows the beam shaper to adapt to different input phase patterns suited for different requirements. Despite imperfections in these consumer pico-projectors, the mGPC approach tolerates phase aberrations that would have otherwise been hard to overcome by standard phase projection. © 2012 Optical Society of America
A Visual Servoing-Based Method for ProCam Systems Calibration
Berry, Francois; Aider, Omar Ait; Mosnier, Jeremie
2013-01-01
Projector-camera systems are currently used in a wide field of applications, such as 3D reconstruction and augmented reality, and can provide accurate measurements, depending on the configuration and calibration. Frequently, the calibration task is divided into two steps: camera calibration followed by projector calibration. The latter still poses certain problems that are not easy to solve, such as the difficulty in obtaining a set of 2D–3D points to compute the projection matrix between the projector and the world. Existing methods are either not sufficiently accurate or not flexible. We propose an easy and automatic method to calibrate such systems that consists in projecting a calibration pattern and superimposing it automatically on a known printed pattern. The projected pattern is provided by a virtual camera observing a virtual pattern in an OpenGL model. The projector displays what the virtual camera visualizes. Thus, the projected pattern can be controlled and superimposed on the printed one with the aid of visual servoing. Our experimental results compare favorably with those of other methods considering both usability and accuracy. PMID:24084121
Nguyen, Van-Giang; Lee, Soo-Jin
2016-07-01
Iterative reconstruction from Compton scattered data is known to be computationally more challenging than that from conventional line-projection based emission data in that the gamma rays that undergo Compton scattering are modeled as conic projections rather than line projections. In conventional tomographic reconstruction, to parallelize the projection and backprojection operations using the graphics processing unit (GPU), approximated methods that use an unmatched pair of ray-tracing forward projector and voxel-driven backprojector have been widely used. In this work, we propose a new GPU-accelerated method for Compton camera reconstruction which is more accurate by using exactly matched pair of projector and backprojector. To calculate conic forward projection, we first sample the cone surface into conic rays and accumulate the intersecting chord lengths of the conic rays passing through voxels using a fast ray-tracing method (RTM). For conic backprojection, to obtain the true adjoint of the conic forward projection, while retaining the computational efficiency of the GPU, we use a voxel-driven RTM which is essentially the same as the standard RTM used for the conic forward projector. Our simulation results show that, while the new method is about 3 times slower than the approximated method, it is still about 16 times faster than the CPU-based method without any loss of accuracy. The net conclusion is that our proposed method is guaranteed to retain the reconstruction accuracy regardless of the number of iterations by providing a perfectly matched projector-backprojector pair, which makes iterative reconstruction methods for Compton imaging faster and more accurate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Superluminescent light emitting diodes: the best out of two worlds
NASA Astrophysics Data System (ADS)
Rossetti, M.; Napierala, J.; Matuschek, N.; Achatz, U.; Duelk, M.; Vélez, C.; Castiglia, A.; Grandjean, N.; Dorsaz, J.; Feltin, E.
2012-03-01
Since pico-projectors were starting to become the next electronic "must-have" gadget, the experts were discussing which light-source technology seems to be the best for the existing three major projection approaches for the optical scanning module such as digital light processing, liquid crystal on silica and laser beam steering. Both so-far used light source technologies have distinct advantages and disadvantages. Though laser-based pico-projectors are focus-free and deliver a wider color gamut, their major disadvantages are speckle noise, cost and safety issues. In contrast, projectors based on cheaper Light Emitting Diodes (LEDs) as light source are criticized for a lack of brightness and for having limited focus. Superluminescent Light Emitting Diodes (SLEDs) are temporally incoherent and spatially coherent light sources merging in one technology the advantages of both Laser Diodes (LDs) and LEDs. With almost no visible speckle noise, focus-free operation and potentially the same color gamut than LDs, SLEDs could potentially answer the question which light source to use in future projector applications. In this quest for the best light source, we realized visible SLEDs emitting both in the red and blue spectral region. While the technology required for the realization of red emitters is already well established, III-nitride compounds required for blue emission have experienced a major development only in relatively recent times and the technology is still under development. The present paper is a review of the status of development reached for the blue superluminescent diodes based on the GaN material system.
Reconstruction method for fringe projection profilometry based on light beams.
Li, Xuexing; Zhang, Zhijiang; Yang, Chen
2016-12-01
A novel reconstruction method for fringe projection profilometry, based on light beams, is proposed and verified by experiments. Commonly used calibration techniques require the parameters of projector calibration or the reference planes placed in many known positions. Obviously, introducing the projector calibration can reduce the accuracy of the reconstruction result, and setting the reference planes to many known positions is a time-consuming process. Therefore, in this paper, a reconstruction method without projector's parameters is proposed and only two reference planes are introduced. A series of light beams determined by the subpixel point-to-point map on the two reference planes combined with their reflected light beams determined by the camera model are used to calculate the 3D coordinates of reconstruction points. Furthermore, the bundle adjustment strategy and the complementary gray-code phase-shifting method are utilized to ensure the accuracy and stability. Qualitative and quantitative comparisons as well as experimental tests demonstrate the performance of our proposed approach, and the measurement accuracy can reach about 0.0454 mm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daffron, James Y.
2003-02-27
Unexploded Ordnance (UXO) removal and investigation projects typically involve multiple organizations including Government entities, private contractors, and technical experts. Resources are split into functional ''teams'' who perform the work and interface with the clients. The projects typically generate large amounts of data that must be shared among the project team members, the clients, and the public. The ability to efficiently communicate and control information is essential to project success. Web-based project collaboration is an effective management and communication tool when applied to ordnance and explosives (OE) projects. During a recent UXO/OE removal project at the Jefferson Proving Ground (JPG) inmore » Madison, IN, American Technologies, Inc. (ATI) successfully used the Project Commander(reg sign) (www.ProCommander.com) project collaboration website as a dynamic project and information management tool.« less
A biomimetic projector with high subwavelength directivity based on dolphin biosonar
NASA Astrophysics Data System (ADS)
Zhang, Yu; Gao, Xiaowei; Zhang, Sai; Cao, Wenwu; Tang, Liguo; Wang, Ding; Li, Yan
2014-09-01
Based on computed tomography of a Yangtze finless porpoise's biosonar system, a biomimetic structure was designed to include air cavity, gradient-index material, and steel outer-structure mimicking air sacs, melon, and skull, respectively. The mainlobe pressure was about three times higher, the angular resolution was one order of magnitude higher, and the effective source size was orders of magnitude larger than those of the subwavelength source without the biomimetic structure. The superior subwavelength directivity over a broad bandwidth suggests potential applications of this biomimetic projector in underwater sonar, medical ultrasonography, and other related applications.
Ubiquitous Presenter: A Tablet PC-based System to Support Instructors and Students
NASA Astrophysics Data System (ADS)
Price, Edward; Simon, Beth
2009-12-01
Digital lecturing systems (computer and projector, often with PowerPoint) offer physics instructors the ability to incorporate graphics and the power to share and reuse materials. But these systems do a poor job of supporting interaction in the classroom. For instance, with digital presentation systems, instructors have limited ability to spontaneously respond to student questions. This limitation is especially acute during classroom activities such as problem solving, Peer Instruction, and Interactive Lecture Demonstrations (ILDs).2 A Tablet PC, a laptop computer with a stylus that can be used to "write" on the screen, provides a way for instructors to add digital ink spontaneously to a presentation in progress. The Tablet PC can be a powerful tool for teaching,3,4 especially when combined with software systems specifically designed to leverage digital ink for pedagogical uses. Ubiquitous Presenter (UP) is one such freely available system.5 Developed at the University of California, San Diego, and based on Classroom Presenter,6 UP allows the instructor to ink prepared digital material (such as exported PowerPoint slides) in real time in class. Ink is automatically archived stroke by stroke and can be reviewed through a web browser (by both students and instructors). The system also supports spontaneous in-class interaction through a web interface—students with web-enabled devices (Tablet PCs, regular laptops, PDAs, and cell phones) can make text-, ink-, or image-based submissions on the instructor's slides. The instructor can review and then project submitted slides to the class and add additional ink, so that material generated by students can be a focus for discussion. A brief video showing UP in action is at http://physics.csusm.edu/UP. In this article, we describe UP and give examples of how UP can support the physics classroom.
Home theater projectors: the next big thing?
NASA Astrophysics Data System (ADS)
Chinnock, Christopher B.
2002-04-01
The business presentation market has traditionally been the mainstay of the projection business, but as these users find the projectors work well at showing movies at home, interest in the home entertainment market is heating up. The idea of creating a theater environment in the home, complete with big screen projector and quality audio system, is not new. Wealthy patrons have been doing it for years. But can the concept be extended to ordinary living rooms? Many think so. Already pioneers like Sony, InFocus, Toshiba and Plus Vision are offering first generation products - and others will follow. But this market will require projectors that have different performance characteristics than those designed for data projection. In this paper, we will discuss how the requirements for a home theater projector differ from those of a data projector. We will provide updated information on who is doing what in this segment and give some insight into the growth potential.
Realizing the increased potential of an open-system high-definition digital projector design
NASA Astrophysics Data System (ADS)
Daniels, Reginald
1999-05-01
Modern video projectors are becoming more compact and capable. Various display technologies are very competitive and are delivering higher performance and more compact projectors to market at an ever quickening pace. However the end users are often left with the daunting task of integrating the 'off the self projectors' into a previously existing system. As the projectors become more digitally enhanced, there will be a series of designs, and the digital projector technology matures. The design solutions will be restricted by the state of the art at the time of manufacturing. In order to allow the most growth and performance for a given price, many design decisions will be made and revisited over a period of years or decades. A modular open digital system design concept is indeed a major challenge of the future high definition digital displays for al applications.
Design of LED projector based on gradient-index lens
NASA Astrophysics Data System (ADS)
Qian, Liyong; Zhu, Xiangbing; Cui, Haitian; Wang, Yuanhang
2018-01-01
In this study, a new type of projector light path is designed to eliminate the deficits of existing projection systems, such as complex structure and low collection efficiency. Using a three-color LED array as the lighting source, by means of the special optical properties of a gradient-index lens, the complex structure of the traditional projector is simplified. Traditional components, such as the color wheel, relay lens, and mirror, become unnecessary. In this way, traditional problems, such as low utilization of light energy and loss of light energy, are solved. With the help of Zemax software, the projection lens is optimized. The optimized projection lens, LED, gradient-index lens, and digital micromirror device are imported into Tracepro. The ray tracing results show that both the utilization of light energy and the uniformity are improved significantly.
NASA Astrophysics Data System (ADS)
Hotta, Aira; Sasaki, Takashi; Okumura, Haruhiko
2007-02-01
In this paper, we propose a novel display method to realize a high-resolution image in a central visual field for a hyper-realistic head dome projector. The method uses image processing based on the characteristics of human vision, namely, high central visual acuity and low peripheral visual acuity, and pixel shift technology, which is one of the resolution-enhancing technologies for projectors. The projected image with our method is a fine wide-viewing-angle image with high definition in the central visual field. We evaluated the psychological effects of the projected images with our method in terms of sensation of reality. According to the result, we obtained 1.5 times higher resolution in the central visual field and a greater sensation of reality by using our method.
NASA Astrophysics Data System (ADS)
Stavroulakis, Petros I.; Chen, Shuxiao; Sims-Waterhouse, Danny; Piano, Samanta; Southon, Nicholas; Bointon, Patrick; Leach, Richard
2017-06-01
In non-rigid fringe projection 3D measurement systems, where either the camera or projector setup can change significantly between measurements or the object needs to be tracked, self-calibration has to be carried out frequently to keep the measurements accurate1. In fringe projection systems, it is common to use methods developed initially for photogrammetry for the calibration of the camera(s) in the system in terms of extrinsic and intrinsic parameters. To calibrate the projector(s) an extra correspondence between a pre-calibrated camera and an image created by the projector is performed. These recalibration steps are usually time consuming and involve the measurement of calibrated patterns on planes, before the actual object can continue to be measured after a motion of a camera or projector has been introduced in the setup and hence do not facilitate fast 3D measurement of objects when frequent experimental setup changes are necessary. By employing and combining a priori information via inverse rendering, on-board sensors, deep learning and leveraging a graphics processor unit (GPU), we assess a fine camera pose estimation method which is based on optimising the rendering of a model of a scene and the object to match the view from the camera. We find that the success of this calibration pipeline can be greatly improved by using adequate a priori information from the aforementioned sources.
Kuipers, Jeroen; Kalicharan, Ruby D; Wolters, Anouk H G; van Ham, Tjakko J; Giepmans, Ben N G
2016-05-25
Large-scale 2D electron microscopy (EM), or nanotomy, is the tissue-wide application of nanoscale resolution electron microscopy. Others and we previously applied large scale EM to human skin pancreatic islets, tissue culture and whole zebrafish larvae(1-7). Here we describe a universally applicable method for tissue-scale scanning EM for unbiased detection of sub-cellular and molecular features. Nanotomy was applied to investigate the healthy and a neurodegenerative zebrafish brain. Our method is based on standardized EM sample preparation protocols: Fixation with glutaraldehyde and osmium, followed by epoxy-resin embedding, ultrathin sectioning and mounting of ultrathin-sections on one-hole grids, followed by post staining with uranyl and lead. Large-scale 2D EM mosaic images are acquired using a scanning EM connected to an external large area scan generator using scanning transmission EM (STEM). Large scale EM images are typically ~ 5 - 50 G pixels in size, and best viewed using zoomable HTML files, which can be opened in any web browser, similar to online geographical HTML maps. This method can be applied to (human) tissue, cross sections of whole animals as well as tissue culture(1-5). Here, zebrafish brains were analyzed in a non-invasive neuronal ablation model. We visualize within a single dataset tissue, cellular and subcellular changes which can be quantified in various cell types including neurons and microglia, the brain's macrophages. In addition, nanotomy facilitates the correlation of EM with light microscopy (CLEM)(8) on the same tissue, as large surface areas previously imaged using fluorescent microscopy, can subsequently be subjected to large area EM, resulting in the nano-anatomy (nanotomy) of tissues. In all, nanotomy allows unbiased detection of features at EM level in a tissue-wide quantifiable manner.
Kuipers, Jeroen; Kalicharan, Ruby D.; Wolters, Anouk H. G.
2016-01-01
Large-scale 2D electron microscopy (EM), or nanotomy, is the tissue-wide application of nanoscale resolution electron microscopy. Others and we previously applied large scale EM to human skin pancreatic islets, tissue culture and whole zebrafish larvae1-7. Here we describe a universally applicable method for tissue-scale scanning EM for unbiased detection of sub-cellular and molecular features. Nanotomy was applied to investigate the healthy and a neurodegenerative zebrafish brain. Our method is based on standardized EM sample preparation protocols: Fixation with glutaraldehyde and osmium, followed by epoxy-resin embedding, ultrathin sectioning and mounting of ultrathin-sections on one-hole grids, followed by post staining with uranyl and lead. Large-scale 2D EM mosaic images are acquired using a scanning EM connected to an external large area scan generator using scanning transmission EM (STEM). Large scale EM images are typically ~ 5 - 50 G pixels in size, and best viewed using zoomable HTML files, which can be opened in any web browser, similar to online geographical HTML maps. This method can be applied to (human) tissue, cross sections of whole animals as well as tissue culture1-5. Here, zebrafish brains were analyzed in a non-invasive neuronal ablation model. We visualize within a single dataset tissue, cellular and subcellular changes which can be quantified in various cell types including neurons and microglia, the brain's macrophages. In addition, nanotomy facilitates the correlation of EM with light microscopy (CLEM)8 on the same tissue, as large surface areas previously imaged using fluorescent microscopy, can subsequently be subjected to large area EM, resulting in the nano-anatomy (nanotomy) of tissues. In all, nanotomy allows unbiased detection of features at EM level in a tissue-wide quantifiable manner. PMID:27285162
Autocalibration of a projector-camera system.
Okatani, Takayuki; Deguchi, Koichiro
2005-12-01
This paper presents a method for calibrating a projector-camera system that consists of multiple projectors (or multiple poses of a single projector), a camera, and a planar screen. We consider the problem of estimating the homography between the screen and the image plane of the camera or the screen-camera homography, in the case where there is no prior knowledge regarding the screen surface that enables the direct computation of the homography. It is assumed that the pose of each projector is unknown while its internal geometry is known. Subsequently, it is shown that the screen-camera homography can be determined from only the images projected by the projectors and then obtained by the camera, up to a transformation with four degrees of freedom. This transformation corresponds to arbitrariness in choosing a two-dimensional coordinate system on the screen surface and when this coordinate system is chosen in some manner, the screen-camera homography as well as the unknown poses of the projectors can be uniquely determined. A noniterative algorithm is presented, which computes the homography from three or more images. Several experimental results on synthetic as well as real images are shown to demonstrate the effectiveness of the method.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... INTERNATIONAL TRADE COMMISSION [DN 2849] Certain Projectors With Controlled-Angle Optical... Re Certain Projectors with Controlled-Angle Optical Retarders, Components Thereof, And Products... complaint. FOR FURTHER INFORMATION CONTACT: James R. Holbein, Secretary to the Commission, U.S...
Center for Coastline Security Technology, Year 3
2008-05-01
Polarization control for 3D Imaging with the Sony SRX-R105 Digital Cinema Projectors 3.4 HDMAX Camera and Sony SRX-R105 Projector Configuration for 3D...HDMAX Camera Pair Figure 3.2 Sony SRX-R105 Digital Cinema Projector Figure 3.3 Effect of camera rotation on projected overlay image. Figure 3.4...system that combines a pair of FAU’s HD-MAX video cameras with a pair of Sony SRX-R105 digital cinema projectors for stereo imaging and projection
Human speckle perception threshold for still images from a laser projection system.
Roelandt, Stijn; Meuret, Youri; Jacobs, An; Willaert, Koen; Janssens, Peter; Thienpont, Hugo; Verschaffelt, Guy
2014-10-06
We study the perception of speckle by human observers in a laser projector based on a 40 persons survey. The speckle contrast is first objectively measured making use of a well-defined speckle measurement method. We statistically analyse the results of the user quality scores, revealing that the speckle perception is not only influenced by the speckle contrast settings of the projector, but it is also strongly influenced by the type of image shown. Based on the survey, we derive a speckle contrast threshold for which speckle can be seen, and separately we investigate a speckle disturbance limit that is tolerated by the majority of test persons.
Recent advancements in system design for miniaturized MEMS-based laser projectors
NASA Astrophysics Data System (ADS)
Scholles, M.; Frommhagen, K.; Gerwig, Ch.; Knobbe, J.; Lakner, H.; Schlebusch, D.; Schwarzenberg, M.; Vogel, U.
2008-02-01
Laser projection systems that use the flying spot principle and which are based on a single MEMS micro scanning mirrors are a very promising way to build ultra-compact projectors that may fit into mobile devices. First demonstrators that show the feasibility of this approach and the applicability of the micro scanning mirror developed by Fraunhofer IPMS for these systems have already been presented. However, a number of items still have to be resolved until miniaturized laser projectors are ready for the market. This contribution describes progress on several different items, each of them of major importance for laser projection systems. First of all, the overall performance of the system has been increased from VGA resolution to SVGA (800×600 pixels) with easy connection to a PC via DVI interface or by using the projector as embedded system with direct camera interface. Secondly, the degree of integration of the electronics has been enhanced by design of an application specific analog front end IC for the micro scanning mirror. It has been fabricated in a special high voltage technology and does not only allow to generate driving signals for the scanning mirror with amplitudes of up to 200V but also integrates position detection of the mirror by several methods. Thirdly, first results concerning Speckle reduction have been achieved, which is necessary for generation of images with high quality. Other aspects include laser modulation and solutions regarding projection on tilted screens which is possible because of the unlimited depth of focus.
Wide-field depth-sectioning fluorescence microscopy using projector-generated patterned illumination
NASA Astrophysics Data System (ADS)
Delica, Serafin; Mar Blanca, Carlo
2007-10-01
We present a simple and cost-effective wide-field, depth-sectioning, fluorescence microscope utilizing a commercial multimedia projector to generate excitation patterns on the sample. Highly resolved optical sections of fluorescent pollen grains at 1.9 μm axial resolution are constructed using the structured illumination technique. This requires grid excitation patterns to be scanned across the sample, which is straightforwardly implemented by creating slideshows of gratings at different phases, projecting them onto the sample, and synchronizing camera acquisition with slide transition. In addition to rapid dynamic pattern generation, the projector provides high illumination power and spectral excitation selectivity. We exploit these properties by imaging mouse neural cells in cultures multistained with Alexa 488 and Cy3. The spectral and structural neural information is effectively resolved in three dimensions. The flexibility and commercial availability of this light source is envisioned to open multidimensional imaging to a broader user base.
Growing Crystals on the Ceiling.
ERIC Educational Resources Information Center
Christman, Robert A.
1980-01-01
Described is a method of studying growing crystals in a classroom utilizing a carrousel projector standing vertically. A saturated salt solution is placed on a slide on the lens of the projector and the heat from the projector causes the water to evaporate and salt to crystalize. (Author/DS)
LCD Projectors: An Evaluation of Features and Utilization for Educators.
ERIC Educational Resources Information Center
Fawson, Curtis E.
1990-01-01
Describes liquid crystal display (LCD) projectors and discusses their use in educational settings. Highlights include rear screen projection; LCD projectors currently available and the number of pixel elements in each; and examples of instructional applications, including portable setups, and use with videocassette recorders (VCRs), computers, and…
Market trends in the projection display industry
NASA Astrophysics Data System (ADS)
Dash, Sweta
2001-03-01
The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection TV segment. Rear LCD (liquid crystal display), MEMS/DLP (or Digital Light Processing TM) and LCOS (Liquid-crystal-on-silicon) TVs are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are also facing challenges from LCD and DLP technology for the home theater market while the business market is completely dominated by front LCD and DLP technology. Three-chip DLP projectors have replaced liquid crystal light valves in large venue applications where projectors have higher light output requirements. In recent years front LCD and LCOS projectors have been increasingly competing with 3-chip DLP projectors especially at the low end of the large venue application market. Within the next five years the projection market will experience very fast growth. Sales and presentation applications, which are the fastest growing applications in the business market, will continue to be the major driving force for the growth for front projectors, and the shift in the consumer market to digital and HDTV products will drive the rear projection market.
The Physics of the Data Projector
ERIC Educational Resources Information Center
Reid, Alastair
2008-01-01
Data projectors have become a common sight in school classrooms, often in conjunction with an interactive whiteboard. Long periods of continuous use coupled with the transfer of a large amount of thermal energy from the projector's bulb means that they frequently break down, often in such a manner that they become uneconomic to repair. In this…
Overhead Projector Spectrum of Polymethine Dye: A Physical Chemistry Demonstration
NASA Astrophysics Data System (ADS)
Solomon, Sally; Hur, Chinhyu
1995-08-01
The position of the predominant peak of 1,1'-diethyl-4,4'-cyanine iodide is measured in class using an overhead projector spectrometer, then predicted using the model of a particle-in a one dimensional box. The calculated wavelength is in excellent agreement with the wavelength estimated from the overhead projector spectroscopy experiment.
Development of electronic cinema projectors
NASA Astrophysics Data System (ADS)
Glenn, William E.
2001-03-01
All of the components for the electronic cinema are now commercially available. Sony has a high definition progressively scanned 24 frame per second electronic cinema camera. This can be recorded digitally on tape or film on hard drives in RAID recorders. Much of the post production processing is now done digitally by scanning film, processing it digitally, and recording it on film for release. Fiber links and satellites can transmit cinema program material to theaters in real time. RAID or tape recorders can play programs for viewing at a much lower cost than storage on film. Two companies now have electronic cinema projectors on the market. Of all of the components, the electronic cinema projector is the most challenging. Achieving the resolution, light, output, contrast ratio, and color rendition all at the same time without visible artifacts is a difficult task. Film itself is, of course, a form of light-valve. However, electronically modulated light uses other techniques rather than changes in density to control the light. The optical techniques that have been the basis for many electronic light-valves have been under development for over 100 years. Many of these techniques are based on optical diffraction to modulate the light. This paper will trace the history of these techniques and show how they may be extended to produce electronic cinema projectors in the future.
Projector-Based Augmented Reality for Quality Inspection of Scanned Objects
NASA Astrophysics Data System (ADS)
Kern, J.; Weinmann, M.; Wursthorn, S.
2017-09-01
After scanning or reconstructing the geometry of objects, we need to inspect the result of our work. Are there any parts missing? Is every detail covered in the desired quality? We typically do this by looking at the resulting point clouds or meshes of our objects on-screen. What, if we could see the information directly visualized on the object itself? Augmented reality is the generic term for bringing virtual information into our real environment. In our paper, we show how we can project any 3D information like thematic visualizations or specific monitoring information with reference to our object onto the object's surface itself, thus augmenting it with additional information. For small objects that could for instance be scanned in a laboratory, we propose a low-cost method involving a projector-camera system to solve this task. The user only needs a calibration board with coded fiducial markers to calibrate the system and to estimate the projector's pose later on for projecting textures with information onto the object's surface. Changes within the projected 3D information or of the projector's pose will be applied in real-time. Our results clearly reveal that such a simple setup will deliver a good quality of the augmented information.
Projection display industry market and technology trends
NASA Astrophysics Data System (ADS)
Castellano, Joseph A.; Mentley, David E.
1995-04-01
The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.
On the regularized fermionic projector of the vacuum
NASA Astrophysics Data System (ADS)
Finster, Felix
2008-03-01
We construct families of fermionic projectors with spherically symmetric regularization, which satisfy the condition of a distributional MP-product. The method is to analyze regularization tails with a power law or logarithmic scaling in composite expressions in the fermionic projector. The resulting regularizations break the Lorentz symmetry and give rise to a multilayer structure of the fermionic projector near the light cone. Furthermore, we construct regularizations which go beyond the distributional MP-product in that they yield additional distributional contributions supported at the origin. The remaining freedom for the regularization parameters and the consequences for the normalization of the fermionic states are discussed.
77 FR 34967 - Notice of Issuance of Final Determination Concerning Digital Projectors
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
... six function tests in the ``post test'', the EDID firmware is programmed into the digital projectors... tests and consists of at least 97 steps taking approximately 137.8 minutes. After the whole projector is... includes 11 kinds of function tests and consists of at least 97 steps which will take approximately 11...
76 FR 30180 - Notice of Issuance of Final Determination Concerning Pocket Projectors
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-24
..., and adhering by electrostatic means. The finished projector will undergo a series of tests in Taiwan: A pre-test, a run-in test, and a function test. The pre-test consists of: ensuring that the... the projector is turned on (developed in Taiwan), (2) test patterns that are projected on the screen...
The Development of a Computer Controlled Super 8 Motion Picture Projector.
ERIC Educational Resources Information Center
Reynolds, Eldon J.
Instructors in Child Development at the University of Texas at Austin selected sound motion pictures as the most effective medium to simulate the observation of children in nursery laboratories. A computer controlled projector was designed for this purpose. An interface and control unit controls the Super 8 projector from a time-sharing computer…
Bulletin Boards and 3-D Showcases That Capture Them with Pizzazz. Volume 2.
ERIC Educational Resources Information Center
Hawthorne, Karen; Gibson, Jane E.
This book features bulletin boards and showcases, designed to motivate readers to use the library, that have been the favorites of students in grades 7-12. Chapter 1 covers getting started, including principles of design, tools of design, background, borders, letters, leaves and flowers, opaque projector/overhead projector/document projector,…
Zhao, Yue; Zhu, Dianwen; Baikejiang, Reheman; Li, Changqing
2015-11-10
This work introduces a fast, low-cost, robust method based on fringe pattern and phase shifting to obtain three-dimensional (3D) mouse surface geometry for fluorescence molecular tomography (FMT) imaging. We used two pico projector/webcam pairs to project and capture fringe patterns from different views. We first calibrated the pico projectors and the webcams to obtain their system parameters. Each pico projector/webcam pair had its own coordinate system. We used a cylindrical calibration bar to calculate the transformation matrix between these two coordinate systems. After that, the pico projectors projected nine fringe patterns with a phase-shifting step of 2π/9 onto the surface of a mouse-shaped phantom. The deformed fringe patterns were captured by the corresponding webcam respectively, and then were used to construct two phase maps, which were further converted to two 3D surfaces composed of scattered points. The two 3D point clouds were further merged into one with the transformation matrix. The surface extraction process took less than 30 seconds. Finally, we applied the Digiwarp method to warp a standard Digimouse into the measured surface. The proposed method can reconstruct the surface of a mouse-sized object with an accuracy of 0.5 mm, which we believe is sufficient to obtain a finite element mesh for FMT imaging. We performed an FMT experiment using a mouse-shaped phantom with one embedded fluorescence capillary target. With the warped finite element mesh, we successfully reconstructed the target, which validated our surface extraction approach.
The Use of a Computer-Controlled Random Access Slide Projector for Rapid Information Display.
ERIC Educational Resources Information Center
Muller, Mark T.
A 35mm random access slide projector operated in conjunction with a computer terminal was adapted to meet the need for a more rapid and complex graphic display mechanism than is currently available with teletypewriter terminals. The model projector can be operated manually to provide for a maintenance checkout of the electromechanical system.…
Full-color laser cathode ray tube (L-CRT) projector
NASA Astrophysics Data System (ADS)
Kozlovskiy, Vladimir; Nasibov, Alexander S.; Popov, Yuri M.; Reznikov, Parvel V.; Skasyrsky, Yan K.
1995-04-01
A full color TV projector based on three laser cathode-ray tubes (L-CRT) is described. A water-cooled laser screen (LS) is the radiation element of the L-CRT. We have produced three main colors (blue, green and red) by using the LS made of three II-VI compounds: ZnSe ((lambda) equals 475 nm), CdS ((lambda) equals 530 nm) and ZnCdSe (630 nm). The total light flow reaches 1500 Lm, and the number of elements per line is not less than 1000. The LS efficiency may be about 10 Lm/W. In our experiments we have tested new electron optics: - (30 - 37) kV are applied to the cathode unit of the electron gun; the anode of the e-gun and the e-beam intensity modulator are under low potential; the LS has a potential + (30 - 37) kV. The accelerating voltage is divided into two parts, and this enables us to diminish the size and weight of the projector.
Liu, Miao; Yang, Shourui; Wang, Zhangying; Huang, Shujun; Liu, Yue; Niu, Zhenqi; Zhang, Xiaoxuan; Zhu, Jigui; Zhang, Zonghua
2016-05-30
Augmented reality system can be applied to provide precise guidance for various kinds of manual works. The adaptability and guiding accuracy of such systems are decided by the computational model and the corresponding calibration method. In this paper, a novel type of augmented reality guiding system and the corresponding designing scheme are proposed. Guided by external positioning equipment, the proposed system can achieve high relative indication accuracy in a large working space. Meanwhile, the proposed system is realized with a digital projector and the general back projection model is derived with geometry relationship between digitized 3D model and the projector in free space. The corresponding calibration method is also designed for the proposed system to obtain the parameters of projector. To validate the proposed back projection model, the coordinate data collected by a 3D positioning equipment is used to calculate and optimize the extrinsic parameters. The final projecting indication accuracy of the system is verified with subpixel pattern projecting technique.
Multi-wavelength speckle reduction for laser pico-projectors using diffractive optics
NASA Astrophysics Data System (ADS)
Thomas, Weston H.
Personal electronic devices, such as cell phones and tablets, continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. Diffusers are often rotated to achieve temporal averaging of the spatial phase pattern provided by diffuser surface. While diffusers are unable to completely eliminate speckle, they can be utilized to decrease the resultant contrast to provide a more visually acceptable image. This dissertation measures the reduction in speckle contrast achievable through the use of diffractive diffusers. A theoretical Fourier optics model is used to provide the diffuser's stationary and in-motion performance in terms of the resultant contrast level. Contrast measurements of two diffractive diffusers are calculated theoretically and compared with experimental results. In addition, a novel binary diffuser design based on Hadamard matrices will be presented. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values were subsequently measured, showing good agreement with theory and simulated values. Monochromatic speckle contrast values of 0.40 were achieved using the Hadamard diffusers. Finally, color laser projection devices require the use of red, green, and blue laser sources; therefore, using a monochromatic diffractive diffuser may not optimal for color speckle contrast reduction. A simulation of the Hadamard diffusers is conducted to determine the optimum spacing between the two diffusers for polychromatic speckle reduction. Experimental measured results are presented using the optimal spacing of Hadamard diffusers for RGB color speckle reduction, showing 60% reduction in contrast.
Design and characterization of an ultraresolution seamlessly tiled display for data visualization
NASA Astrophysics Data System (ADS)
Bordes, Nicole; Bleha, William P.; Pailthorpe, Bernard
2003-09-01
The demand for more pixels in digital displays is beginning to be met as manufacturers increase the native resolution of projector chips. Tiling several projectors still offers one solution to augment the pixel capacity of a display. However problems of color and illumination uniformity across projectors need to be addressed as well as the computer software required to drive such devices. In this paper we present the results obtained on a desktop size tiled projector array of three D-ILA projectors sharing a common illumination source. The composite image on a 3 x 1 array, is 3840 by 1024 pixels with a resolution of about 80 dpi. The system preserves desktop resolution, is compact and can fit in a normal room or laboratory. A fiber optic beam splitting system and a single set of red, green and blue dichroic filters are the key to color and illumination uniformity. The D-ILA chips inside each projector can be adjusted individually to set or change characteristics such as contrast, brightness or gamma curves. The projectors were matched carefully and photometric variations were corrected, leading to a seamless tiled image. Photometric measurements were performed to characterize the display and losses through the optical paths, and are reported here. This system is driven by a small PC computer cluster fitted with graphics cards and is running Linux. The Chromium API can be used for tiling graphics tiles across the display and interfacing to users' software applications. There is potential for scaling the design to accommodate larger arrays, up to 4x5 projectors, increasing display system capacity to 50 Megapixels. Further increases, beyond 100 Megapixels can be anticipated with new generation D-ILA chips capable of projecting QXGA (2k x 1.5k), with ongoing evolution as QUXGA (4k x 2k) becomes available.
Overhead Projector Demonstrations.
ERIC Educational Resources Information Center
Kolb, Doris, Ed.
1987-01-01
Describes several chemistry demonstrations that use an overhead projector. Some of the demonstrations deal with electrochemistry, and another deals with the reactions of nonvolatile immiscible liquid in water. (TW)
The s-Ordered Fock Space Projectors Gained by the General Ordering Theorem
NASA Astrophysics Data System (ADS)
Farid, Shähandeh; Mohammad, Reza Bazrafkan; Mahmoud, Ashrafi
2012-09-01
Employing the general ordering theorem (GOT), operational methods and incomplete 2-D Hermite polynomials, we derive the t-ordered expansion of Fock space projectors. Using the result, the general ordered form of the coherent state projectors is obtained. This indeed gives a new integration formula regarding incomplete 2-D Hermite polynomials. In addition, the orthogonality relation of the incomplete 2-D Hermite polynomials is derived to resolve Dattoli's failure.
NASA Astrophysics Data System (ADS)
Peterson, David
2005-11-01
The audio and visual capabilities of the planetarium at Francis Marion University were upgraded in Fall 2004 to incorporate three Barco CRT projectors and surround sound. Controlled by the Astro-FX media manager system developed by Bowen Technovation, the projectors focus on the 33 foot dome installed in 1978 for the Spitz 512 Star projector. The significant additional capabilities of the new combined systems will be presented together with a review of the planetarium renovation procedure.
Controllable 3D Display System Based on Frontal Projection Lenticular Screen
NASA Astrophysics Data System (ADS)
Feng, Q.; Sang, X.; Yu, X.; Gao, X.; Wang, P.; Li, C.; Zhao, T.
2014-08-01
A novel auto-stereoscopic three-dimensional (3D) projection display system based on the frontal projection lenticular screen is demonstrated. It can provide high real 3D experiences and the freedom of interaction. In the demonstrated system, the content can be changed and the dense of viewing points can be freely adjusted according to the viewers' demand. The high dense viewing points can provide smooth motion parallax and larger image depth without blurry. The basic principle of stereoscopic display is described firstly. Then, design architectures including hardware and software are demonstrated. The system consists of a frontal projection lenticular screen, an optimally designed projector-array and a set of multi-channel image processors. The parameters of the frontal projection lenticular screen are based on the demand of viewing such as the viewing distance and the width of view zones. Each projector is arranged on an adjustable platform. The set of multi-channel image processors are made up of six PCs. One of them is used as the main controller, the other five client PCs can process 30 channel signals and transmit them to the projector-array. Then a natural 3D scene will be perceived based on the frontal projection lenticular screen with more than 1.5 m image depth in real time. The control section is presented in detail, including parallax adjustment, system synchronization, distortion correction, etc. Experimental results demonstrate the effectiveness of this novel controllable 3D display system.
Optimization of freeform lightpipes for light-emitting-diode projectors.
Fournier, Florian; Rolland, Jannick
2008-03-01
Standard nonimaging components used to collect and integrate light in light-emitting-diode-based projector light engines such as tapered rods and compound parabolic concentrators are compared to optimized freeform shapes in terms of transmission efficiency and spatial uniformity. We show that the simultaneous optimization of the output surface and the profile shape yields transmission efficiency within the étendue limit up to 90% and spatial uniformity higher than 95%, even for compact sizes. The optimization process involves a manual study of the trends for different shapes and the use of an optimization algorithm to further improve the performance of the freeform lightpipe.
Acoustic beam control in biomimetic projector via velocity gradient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Xiaowei; Dong, Erqian; Song, Zhongchang
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Acoustic beam control in biomimetic projector via velocity gradient
NASA Astrophysics Data System (ADS)
Gao, Xiaowei; Zhang, Yu; Cao, Wenwu; Dong, Erqian; Song, Zhongchang; Li, Songhai; Tang, Liguo; Zhang, Sai
2016-07-01
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Optimization of freeform lightpipes for light-emitting-diode projectors
NASA Astrophysics Data System (ADS)
Fournier, Florian; Rolland, Jannick
2008-03-01
Standard nonimaging components used to collect and integrate light in light-emitting-diode-based projector light engines such as tapered rods and compound parabolic concentrators are compared to optimized freeform shapes in terms of transmission efficiency and spatial uniformity. We show that the simultaneous optimization of the output surface and the profile shape yields transmission efficiency within the étendue limit up to 90% and spatial uniformity higher than 95%, even for compact sizes. The optimization process involves a manual study of the trends for different shapes and the use of an optimization algorithm to further improve the performance of the freeform lightpipe.
Applying AR technology with a projector-camera system in a history museum
NASA Astrophysics Data System (ADS)
Miyata, Kimiyoshi; Shiroishi, Rina; Inoue, Yuka
2011-01-01
In this research, an AR (augmented reality) technology with projector-camera system is proposed for a history museum to provide user-friendly interface and pseudo hands-on exhibition. The proposed system is a desktop application and designed for old Japanese coins to enhance the visitors' interests and motivation to investigate them. The size of the old coins are small to recognize their features and the surface of the coins has fine structures on both sides, so it is meaningful to show the reverse side and enlarged image of the coins to the visitors for enhancing their interest and motivation. The image of the reverse side of the coins is displayed based on the AR technology to reverse the AR marker by the user. The information to augment the coins is projected by using a data projector, and the information is placed nearby the coins. The proposed system contributes to develop an exhibition method based on the combinations of the real artifacts and the AR technology, and demonstrated the flexibility and capability to offer background information relating to the old Japanese coins. However, the accuracy of the detection and tracking of the markers and visitor evaluation survey are required to improve the effectiveness of the system.
NASA Astrophysics Data System (ADS)
Chen, Enguo; Liu, Peng; Yu, Feihong
2012-10-01
A novel synchronized optimization method of multiple freeform surfaces is proposed and applied to double lenses illumination system design of CF-LCoS pico-projectors. Based on Snell's law and the energy conservation law, a series of first-order partial differential equations are derived for the multiple freeform surfaces of the initial system. By assigning the light deflection angle to each freeform surface, multiple surfaces can be obtained simultaneously by solving the corresponding equations, meanwhile the restricted angle on CF-LCoS is guaranteed. In order to improve the spatial uniformity, the multi-surfaces are synchronously optimized by using simplex algorithm for an extended LED source. Design example shows that the double lenses based illumination system, which employs a single 2 mm×2 mm LED chip and a CF-LCoS panel with a diagonal of 0.59 inches satisfies the needs of pico-projector. Moreover, analytical result indicates that the design method represents substantial improvement and practical significance over traditional CF-LCoS projection system, which could offer outstanding performance with both portability and low cost. The synchronized optimization design method could not only realize collimating and uniform illumination, but also could be introduced to other specific light conditions.
Night vision goggle stimulation using LCoS and DLP projection technology, which is better?
NASA Astrophysics Data System (ADS)
Ali, Masoud H.; Lyon, Paul; De Meerleer, Peter
2014-06-01
High fidelity night-vision training has become important for many of the simulation systems being procured today. The end-users of these simulation-training systems prefer using their actual night-vision goggle (NVG) headsets. This requires that the visual display system stimulate the NVGs in a realistic way. Historically NVG stimulation was done with cathode-ray tube (CRT) projectors. However, this technology became obsolete and in recent years training simulators do NVG stimulation with laser, LCoS and DLP projectors. The LCoS and DLP projection technologies have emerged as the preferred approach for the stimulation of NVGs. Both LCoS and DLP technologies have advantages and disadvantages for stimulating NVGs. LCoS projectors can have more than 5-10 times the contrast capability of DLP projectors. The larger the difference between the projected black level and the brightest object in a scene, the better the NVG stimulation effects can be. This is an advantage of LCoS technology, especially when the proper NVG wavelengths are used. Single-chip DLP projectors, even though they have much reduced contrast compared to LCoS projectors, can use LED illuminators in a sequential red-green-blue fashion to create a projected image. It is straightforward to add an extra infrared (NVG wavelength) LED into this sequential chain of LED illumination. The content of this NVG channel can be independent of the visible scene, which allows effects to be added that can compensate for the lack of contrast inherent in a DLP device. This paper will expand on the differences between LCoS and DLP projectors for stimulating NVGs and summarize the benefits of both in night-vision simulation training systems.
Autocalibration of multiprojector CAVE-like immersive environments.
Sajadi, Behzad; Majumder, Aditi
2012-03-01
In this paper, we present the first method for the geometric autocalibration of multiple projectors on a set of CAVE-like immersive display surfaces including truncated domes and 4 or 5-wall CAVEs (three side walls, floor, and/or ceiling). All such surfaces can be categorized as swept surfaces and multiple projectors can be registered on them using a single uncalibrated camera without using any physical markers on the surface. Our method can also handle nonlinear distortion in the projectors, common in compact setups where a short throw lens is mounted on each projector. Further, when the whole swept surface is not visible from a single camera view, we can register the projectors using multiple pan and tilted views of the same camera. Thus, our method scales well with different size and resolution of the display. Since we recover the 3D shape of the display, we can achieve registration that is correct from any arbitrary viewpoint appropriate for head-tracked single-user virtual reality systems. We can also achieve wallpapered registration, more appropriate for multiuser collaborative explorations. Though much more immersive than common surfaces like planes and cylinders, general swept surfaces are used today only for niche display environments. Even the more popular 4 or 5-wall CAVE is treated as a piecewise planar surface for calibration purposes and hence projectors are not allowed to be overlapped across the corners. Our method opens up the possibility of using such swept surfaces to create more immersive VR systems without compromising the simplicity of having a completely automatic calibration technique. Such calibration allows completely arbitrary positioning of the projectors in a 5-wall CAVE, without respecting the corners.
NASA Astrophysics Data System (ADS)
Robinson, Dirk; Stork, David G.
2008-02-01
A recent theory claims that the late-Italian Renaissance painter Lorenzo Lotto secretly built a concave-mirror projector to project an image of a carpet onto his canvas and trace it during the execution of Husband and wife (c. 1543). Key evidence adduced to support this claim includes "perspective anomalies" and changes in "magnification" that the theory's proponents ascribe to Lotto refocusing his projector to overcome its limitations in depth of field. We find, though, that there are important geometrical constraints upon such a putative optical projector not incorporated into the proponents' analyses, and that when properly included, the argument for the use of optics loses its force. We used Zemax optical design software to create a simple model of Lotto's studio and putative projector, and incorporated the optical properties proponents inferred from geometrical properties of the depicted carpet. Our central contribution derives from including the 116-cm-wide canvas screen; we found that this screen forces the incident light to strike the concave mirror at large angles (>= 15°) and that this, in turn, means that the projected image would reveal severe off-axis aberrations, particularly astigmatism. Such aberrations are roughly as severe as the defocus blur claimed to have led Lotto to refocus the projector. In short, we find that the projected images would not have gone in and out of focus in the way claimed by proponents, a result that undercuts their claim that Lotto used a projector for this painting. We speculate on the value of further uses of sophisticated ray-tracing analyses in the study of fine arts.
Aberration analyses for improving the frontal projection three-dimensional display.
Gao, Xin; Sang, Xinzhu; Yu, Xunbo; Wang, Peng; Cao, Xuemei; Sun, Lei; Yan, Binbin; Yuan, Jinhui; Wang, Kuiru; Yu, Chongxiu; Dou, Wenhua
2014-09-22
The crosstalk severely affects the viewing experience for the auto-stereoscopic 3D displays based on frontal projection lenticular sheet. To suppress unclear stereo vision and ghosts are observed in marginal viewing zones(MVZs), aberration of the lenticular sheet combining with the frontal projector is analyzed and designed. Theoretical and experimental results show that increasing radius of curvature (ROC) or decreasing aperture of the lenticular sheet can suppress the aberration and reduce the crosstalk. A projector array with 20 micro-projectors is used to frontally project 20 parallax images one lenticular sheet with the ROC of 10 mm and the size of 1.9 m × 1.2 m. The 3D image with the high quality is experimentally demonstrated in both the mid-viewing zone and MVZs in the optimal viewing plane. The 3D clear depth of 1.2m can be perceived. To provide an excellent 3D image and enlarge the field of view at the same time, a novel structure of lenticular sheet is presented to reduce aberration, and the crosstalk is well suppressed.
Emerging digital micromirror device (DMD) applications
NASA Astrophysics Data System (ADS)
Dudley, Dana; Duncan, Walter M.; Slaughter, John
2003-01-01
For the past six years, Digital Light Processing technology from Texas Instruments has made significant inroads in the projection display market. With products enabling the world"s smallest data and video projectors, HDTVs, and digital cinema, DLP technology is extremely powerful and flexible. At the heart of these display solutions is Texas Instruments Digital Micromirror Device (DMD), a semiconductor-based "light switch" array of thousands of individually addressable, tiltable, mirror-pixels. With success of the DMD as a spatial light modulator for projector applications, dozens of new applications are now being enabled by general-use DMD products that are recently available to developers. The same light switching speed and "on-off" (contrast) ratio that have resulted in superior projector performance, along with the capability of operation outside the visible spectrum, make the DMD very attractive for many applications, including volumetric display, holographic data storage, lithography, scientific instrumentation, and medical imaging. This paper presents an overview of past and future DMD performance in the context of new DMD applications, cites several examples of emerging products, and describes the DMD components and tools now available to developers.
A micro-machined source transducer for a parametric array in air.
Lee, Haksue; Kang, Daesil; Moon, Wonkyu
2009-04-01
Parametric array applications in air, such as highly directional parametric loudspeaker systems, usually rely on large radiators to generate the high-intensity primary beams required for nonlinear interactions. However, a conventional transducer, as a primary wave projector, requires a great deal of electrical power because its electroacoustic efficiency is very low due to the large characteristic mechanical impedance in air. The feasibility of a micro-machined ultrasonic transducer as an efficient finite-amplitude wave projector was studied. A piezoelectric micro-machined ultrasonic transducer array consisting of lead zirconate titanate uni-morph elements was designed and fabricated for this purpose. Theoretical and experimental evaluations showed that a micro-machined ultrasonic transducer array can be used as an efficient source transducer for a parametric array in air. The beam patterns and propagation curves of the difference frequency wave and the primary wave generated by the micro-machined ultrasonic transducer array were measured. Although the theoretical results were based on ideal parametric array models, the theoretical data explained the experimental results reasonably well. These experiments demonstrated the potential of micro-machined primary wave projector.
ERIC Educational Resources Information Center
TechTrends, 1992
1992-01-01
Reviews new educational technology products, including a microcomputer-based tutoring system, laser barcode reader, video/data projectors, CD-ROM for notebook computers, a system to increase a printer's power, data cartridge storage shell, knowledge-based decision tool, video illustrator, interactive videodiscs, surge protectors, scanner system,…
Jiang, Hongzhi; Zhao, Huijie; Li, Xudong; Quan, Chenggen
2016-03-07
We propose a novel hyper thin 3D edge measurement technique to measure the profile of 3D outer envelope of honeycomb core structures. The width of the edges of the honeycomb core is less than 0.1 mm. We introduce a triangular layout design consisting of two cameras and one projector to measure hyper thin 3D edges and eliminate data interference from the walls. A phase-shifting algorithm and the multi-frequency heterodyne phase-unwrapping principle are applied for phase retrievals on edges. A new stereo matching method based on phase mapping and epipolar constraint is presented to solve correspondence searching on the edges and remove false matches resulting in 3D outliers. Experimental results demonstrate the effectiveness of the proposed method for measuring the 3D profile of honeycomb core structures.
Caryoscope: An Open Source Java application for viewing microarray data in a genomic context
Awad, Ihab AB; Rees, Christian A; Hernandez-Boussard, Tina; Ball, Catherine A; Sherlock, Gavin
2004-01-01
Background Microarray-based comparative genome hybridization experiments generate data that can be mapped onto the genome. These data are interpreted more easily when represented graphically in a genomic context. Results We have developed Caryoscope, which is an open source Java application for visualizing microarray data from array comparative genome hybridization experiments in a genomic context. Caryoscope can read General Feature Format files (GFF files), as well as comma- and tab-delimited files, that define the genomic positions of the microarray reporters for which data are obtained. The microarray data can be browsed using an interactive, zoomable interface, which helps users identify regions of chromosomal deletion or amplification. The graphical representation of the data can be exported in a number of graphic formats, including publication-quality formats such as PostScript. Conclusion Caryoscope is a useful tool that can aid in the visualization, exploration and interpretation of microarray data in a genomic context. PMID:15488149
Overhead Projector Demonstrations.
ERIC Educational Resources Information Center
Kolb, Doris, Ed.
1989-01-01
Described are demonstrations of the optical activity of two sugar solutions, and the effects of various substituents on acid strength using an overhead projector. Materials and procedures for each demonstration are discussed. (CW)
The algebraic theory of latent projectors in lambda matrices
NASA Technical Reports Server (NTRS)
Denman, E. D.; Leyva-Ramos, J.; Jeon, G. J.
1981-01-01
Multivariable systems such as a finite-element model of vibrating structures, control systems, and large-scale systems are often formulated in terms of differential equations which give rise to lambda matrices. The present investigation is concerned with the formulation of the algebraic theory of lambda matrices and the relationship of latent roots, latent vectors, and latent projectors to the eigenvalues, eigenvectors, and eigenprojectors of the companion form. The chain rule for latent projectors and eigenprojectors for the repeated latent root or eigenvalues is given.
40. View of dual projector system located in MWOC facility ...
40. View of dual projector system located in MWOC facility in transmitter building no. 102 by Bessler Company. System used to project images in MWOC on backlit screen system with fiber optic electro/mechanical system linked to computer output to indicate information on screen linked with display from projector system. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Overhead Projector Demonstrations.
ERIC Educational Resources Information Center
Kolb, Doris, Ed.
1989-01-01
Included are demonstrations using the overhead projector to show change in optical rotation with wavelength and aromatic pi cloud availability, and formation of colored charge-transfer complexes. Instructional techniques unique to these topics are discussed. (CW)
NASA Astrophysics Data System (ADS)
Graham-Rowe, Duncan
2007-12-01
As the size of handheld gadgets decreases, their displays become harder to view. The solution could lie with integrated projectors that can project crisp, large images from mobile devices onto any chosen surface. Duncan Graham-Rowe reports.
The research on multi-projection correction based on color coding grid array
NASA Astrophysics Data System (ADS)
Yang, Fan; Han, Cheng; Bai, Baoxing; Zhang, Chao; Zhao, Yunxiu
2017-10-01
There are many disadvantages such as lower timeliness, greater manual intervention in multi-channel projection system, in order to solve the above problems, this paper proposes a multi-projector correction technology based on color coding grid array. Firstly, a color structured light stripe is generated by using the De Bruijn sequences, then meshing the feature information of the color structured light stripe image. We put the meshing colored grid intersection as the center of the circle, and build a white solid circle as the feature sample set of projected images. It makes the constructed feature sample set not only has the perceptual localization, but also has good noise immunity. Secondly, we establish the subpixel geometric mapping relationship between the projection screen and the individual projectors by using the structure of light encoding and decoding based on the color array, and the geometrical mapping relation is used to solve the homography matrix of each projector. Lastly the brightness inconsistency of the multi-channel projection overlap area is seriously interfered, it leads to the corrected image doesn't fit well with the observer's visual needs, and we obtain the projection display image of visual consistency by using the luminance fusion correction algorithm. The experimental results show that this method not only effectively solved the problem of distortion of multi-projection screen and the issue of luminance interference in overlapping region, but also improved the calibration efficient of multi-channel projective system and reduced the maintenance cost of intelligent multi-projection system.
On the use of video projectors for three-dimensional scanning
NASA Astrophysics Data System (ADS)
Juarez-Salazar, Rigoberto; Diaz-Ramirez, Victor H.; Robledo-Sanchez, Carlos; Diaz-Gonzalez, Gerardo
2017-08-01
Structured light projection is one of the most useful methods for accurate three-dimensional scanning. Video projectors are typically used as the illumination source. However, because video projectors are not designed for structured light systems, some considerations such as gamma calibration must be taken into account. In this work, we present a simple method for gamma calibration of video projectors. First, the experimental fringe patterns are normalized. Then, the samples of the fringe patterns are sorted in ascending order. The sample sorting leads to a simple three-parameter sine curve that is fitted using the Gauss-Newton algorithm. The novelty of this method is that the sorting process removes the effect of the unknown phase. Thus, the resulting gamma calibration algorithm is significantly simplified. The feasibility of the proposed method is illustrated in a three-dimensional scanning experiment.
NASA Astrophysics Data System (ADS)
Takizawa, Kuniharu
A novel three-dimensional (3-D) projection display used with polarized eyeglasses is proposed. It consists of polymer-dispersed liquid crystal-light valves that modulate the illuminated light based on light scattering, a polarization beam splitter, and a Schlieren projection system. The features of the proposed display include a 3-D image display with a single projector, half size and half power consumption compared with a conventional 3-D projector with polarized glasses. Measured electro-optic characteristics of a polymer-dispersed liquid-crystal cell inserted between crossed polarizers suggests that the proposed display achieves small cross talk and high-extinction ratio.
Market trends in the projection display industry
NASA Astrophysics Data System (ADS)
Dash, Sweta
2000-04-01
The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection television segment. But rear LCD (liquid crystal display) and rear reflective (DLP, or Digital Light ProcessingTM) televisions are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are still popular in the high-end home theater market. Front LCD technology and front DLP technology dominate the business market. Traditional light valve technology was the only solution for applications requiring high light outputs, but new three-chip DLP projectors meet the higher light output requirements at a lower price. In the last few years the strongest growth has been in the business market for multimedia presentation applications. This growth was due to the continued increase in display pixel formats, the continued reduction in projector weight, and the improved price/performance ratio. The projection display market will grow at a significant rate during the next five years, driven by the growth in ultraportable (< 10 pound) projectors and the shift in the consumer market to digital and HDTV products.
Cohen, Michael X; Weidacker, Kathrin; Tankink, Judith; Scholte, H Steven; Rouw, Romke
2015-01-01
Grapheme-color synesthesia is a condition in which seeing letters and numbers produces sensations of colors (e.g., the letter R may elicit a sky-blue percept). Recent evidence implicates posterior parietal areas, in addition to lower-level sensory processing regions, in the neurobiological mechanisms involved in synesthesia. Furthermore, these mechanisms seem to differ for "projectors" (synesthetes who report seeing the color "out there in the real world") versus "associators" (synesthetes who report the color to be only an internal experience). Relatively little is known about possible electrophysiological characteristics of grapheme-color synesthesia. Here we used EEG to investigate functional oscillatory differences among associators, projectors, and non-synesthetes. Projectors had stronger stimulus-related alpha-band (~10 Hz) power over posterior parietal electrodes, compared to both associators and non-synesthetes. Posterior alpha activity was not statistically significantly different between associators from non-synesthetes. We also performed a test-retest assessment of the projector-associator score and found strong retest reliability, as evidenced by a correlation coefficient of .85. These findings demonstrate that the projector-associator distinction is highly reliable over time and is related to neural oscillations in the alpha band.
Projector Center: Using an Overhead Projector to Initiate Discussion of Life and Non-Life.
ERIC Educational Resources Information Center
Barman, Charles R.
1982-01-01
Describes a demonstration and role-playing activity focusing on differences between living/dead, definitions of living/dead, and situations in which active euthanasia could be morally right. (Author/JN)
Overhead Projector Demonstrations: Tilted TOPS: Inclined Plane Projection.
ERIC Educational Resources Information Center
Alyea, Hubert N.
1989-01-01
The construction and uses of a device to facilitate the use of an overhead projector to show chemical reactions is presented. Materials and instructions for construction as well as reactor vessels are discussed. (CW)
Speckle perception and disturbance limit in laser based projectors
NASA Astrophysics Data System (ADS)
Verschaffelt, Guy; Roelandt, Stijn; Meuret, Youri; Van den Broeck, Wendy; Kilpi, Katriina; Lievens, Bram; Jacobs, An; Janssens, Peter; Thienpont, Hugo
2016-04-01
We investigate the level of speckle that can be tolerated in a laser cinema projector. For this purpose, we equipped a movie theatre room with a prototype laser projector. A group of 186 participants was gathered to evaluate the speckle perception of several, short movie trailers in a subjective `Quality of Experience' experiment. This study is important as the introduction of lasers in projection systems has been hampered by the presence of speckle in projected images. We identify a speckle disturbance threshold by statistically analyzing the observers' responses for different values of the amount of speckle, which was monitored using a well-defined speckle measurement method. The analysis shows that the speckle perception of a human observer is not only dependent on the objectively measured amount of speckle, but it is also strongly influenced by the image content. As is also discussed in [Verschaffelt et al., Scientific Reports 5, art. nr. 14105, 2015] we find that, for moving images, the speckle becomes disturbing if the speckle contrast becomes larger than 6.9% for the red, 6.0% for the green, and 4.8% for the blue primary colors of the projector, whereas for still images the speckle detection threshold is about 3%. As we could not independently tune the speckle contrast of each of the primary colors, this speckle disturbance limit seems to be determined by the 6.9% speckle contrast of the red color as this primary color contains the largest amount of speckle. The speckle disturbance limit for movies thus turns out to be substantially larger than that for still images, and hence is easier to attain.
Krempien, Robert; Hoppe, Harald; Kahrs, Lüder; Daeuber, Sascha; Schorr, Oliver; Eggers, Georg; Bischof, Marc; Munter, Marc W; Debus, Juergen; Harms, Wolfgang
2008-03-01
The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.
Connecting congregations: technology resources influence parish nurse practice.
Zerull, Lisa M; Near, Kelly K; Ragon, Bart; Farrell, Sarah P
2009-01-01
This descriptive pilot study evaluated the influence of health resource information education and the use of Web-based communication technology on the professional practice of the parish nurse in the congregational setting. Five parish nurse participants from varied denominations in rural and nonrural Virginia received a laptop computer, printer, video projector, and webcam along with high-speed Internet access in each congregational setting. The nurses attended two group education sessions that incorporated computer applications and training in accessing and using quality health information resources and communication applications such as a group "chat" software and webcam to communicate with others through high-speed Internet access. Qualitative analysis from semistructured interviews of nurses confirmed that participants found the project to be beneficial in terms of awareness, education, and applicability of technology use in parish nurse practice. Quantitative data from preproject and postproject surveys found significant differences in nurses' abilities and confidence with technology use and application. Findings showed that the knowledge and experience gained from this study enhanced parish nurse practice and confidence in using technology for communication, health education, and counseling.
Overhead Projector Demonstrations: A Classroom Demonstration of Aliphatic Substitution.
ERIC Educational Resources Information Center
Perina, Ivo; Mihanovic, Branka
1989-01-01
Presents a halogen substitution of an alkane using a compartmentalized Petri dish or Conway dish on an overhead projector. Provides methodology and several modifications for different reactions. Uses hexane, methyl orange, bromine, and silver nitrate. (MVL)
The causal perturbation expansion revisited: Rescaling the interacting Dirac sea
NASA Astrophysics Data System (ADS)
Finster, Felix; Grotz, Andreas
2010-07-01
The causal perturbation expansion defines the Dirac sea in the presence of a time-dependent external field. It yields an operator whose image generalizes the vacuum solutions of negative energy and thus gives a canonical splitting of the solution space into two subspaces. After giving a self-contained introduction to the ideas and techniques, we show that this operator is, in general, not idempotent. We modify the standard construction by a rescaling procedure giving a projector on the generalized negative-energy subspace. The resulting rescaled causal perturbation expansion uniquely defines the fermionic projector in terms of a series of distributional solutions of the Dirac equation. The technical core of the paper is to work out the combinatorics of the expansion in detail. It is also shown that the fermionic projector with interaction can be obtained from the free projector by a unitary transformation. We finally analyze the consequences of the rescaling procedure on the light-cone expansion.
Huang, Junhui; Xue, Qi; Wang, Zhao; Gao, Jianmin
2016-09-03
While color-coding methods have improved the measuring efficiency of a structured light three-dimensional (3D) measurement system, they decreased the measuring accuracy significantly due to lateral chromatic aberration (LCA). In this study, the LCA in a structured light measurement system is analyzed, and a method is proposed to compensate the error caused by the LCA. Firstly, based on the projective transformation, a 3D error map of LCA is constructed in the projector images by using a flat board and comparing the image coordinates of red, green and blue circles with the coordinates of white circles at preselected sample points within the measurement volume. The 3D map consists of the errors, which are the equivalent errors caused by LCA of the camera and projector. Then in measurements, error values of LCA are calculated and compensated to correct the projector image coordinates through the 3D error map and a tri-linear interpolation method. Eventually, 3D coordinates with higher accuracy are re-calculated according to the compensated image coordinates. The effectiveness of the proposed method is verified in the following experiments.
Huang, Junhui; Xue, Qi; Wang, Zhao; Gao, Jianmin
2016-01-01
While color-coding methods have improved the measuring efficiency of a structured light three-dimensional (3D) measurement system, they decreased the measuring accuracy significantly due to lateral chromatic aberration (LCA). In this study, the LCA in a structured light measurement system is analyzed, and a method is proposed to compensate the error caused by the LCA. Firstly, based on the projective transformation, a 3D error map of LCA is constructed in the projector images by using a flat board and comparing the image coordinates of red, green and blue circles with the coordinates of white circles at preselected sample points within the measurement volume. The 3D map consists of the errors, which are the equivalent errors caused by LCA of the camera and projector. Then in measurements, error values of LCA are calculated and compensated to correct the projector image coordinates through the 3D error map and a tri-linear interpolation method. Eventually, 3D coordinates with higher accuracy are re-calculated according to the compensated image coordinates. The effectiveness of the proposed method is verified in the following experiments. PMID:27598174
Quantum Foundations of Quantum Information
NASA Astrophysics Data System (ADS)
Griffiths, Robert
2009-03-01
The main foundational issue for quantum information is: What is quantum information about? What does it refer to? Classical information typically refers to physical properties, and since classical is a subset of quantum information (assuming the world is quantum mechanical), quantum information should--and, it will be argued, does--refer to quantum physical properties represented by projectors on appropriate subspaces of a quantum Hilbert space. All sorts of microscopic and macroscopic properties, not just measurement outcomes, can be represented in this way, and are thus a proper subject of quantum information. The Stern-Gerlach experiment illustrates this. When properties are compatible, which is to say their projectors commute, Shannon's classical information theory based on statistical correlations extends without difficulty or change to the quantum case. When projectors do not commute, giving rise to characteristic quantum effects, a foundation for the subject can still be constructed by replacing the ``measurement and wave-function collapse'' found in textbooks--an efficient calculational tool, but one giving rise to numerous conceptual difficulties--with a fully consistent and paradox free stochastic formulation of standard quantum mechanics. This formulation is particularly helpful in that it contains no nonlocal superluminal influences; the reason the latter carry no information is that they do not exist.
Six-color solid state illuminator for cinema projector
NASA Astrophysics Data System (ADS)
Huang, Junejei; Wang, Yuchang
2014-09-01
Light source for cinema projector requires reliability, high brightness, good color and 3D for without silver screens. To meet these requirements, a laser-phosphor based solid state illuminator with 6 primary colors is proposed. The six primary colors are divided into two groups and include colors of R1, R2, G1, G2, B1 and B2. Colors of B1, B2 and R2 come from lasers of wavelengths 440 nm, 465 nm and 639 nm. Color of G1 comes from G-phosphor pumped by B2 laser. Colors of G2 and R1 come from Y-phosphor pumped by B1 laser. Two groups of colors are combined by a multiband filter and working by alternately switching B1 and B2 lasers. The combined two sequences of three colors are sent to the 3-chip cinema projector and synchronized with frame rate of 120Hz. In 2D mode, the resulting 6 primary colors provide a very wide color gamut. In 3D mode, two groups of red, green and blue primary colors provide two groups of images that received by left and right eyes.
Efficient green lasers for high-resolution scanning micro-projector displays
NASA Astrophysics Data System (ADS)
Bhatia, Vikram; Bauco, Anthony S.; Oubei, Hassan M.; Loeber, David A. S.
2010-02-01
Laser-based projectors are gaining increased acceptance in mobile device market due to their low power consumption, superior image quality and small size. The basic configuration of such micro-projectors is a miniature mirror that creates an image by raster scanning the collinear red, blue and green laser beams that are individually modulated on a pixel-bypixel basis. The image resolution of these displays can be limited by the modulation bandwidth of the laser sources, and the modulation speed of the green laser has been one of the key limitations in the development of these displays. We will discuss how this limitation is fundamental to the architecture of many laser designs and then present a green laser configuration which overcomes these difficulties. In this green laser architecture infra-red light from a distributed Bragg-reflector (DBR) laser diode undergoes conversion to green light in a waveguided second harmonic generator (SHG) crystal. The direct doubling in a single pass through the SHG crystal allows the device to operate at the large modulation bandwidth of the DBR laser. We demonstrate that the resultant product has a small footprint (<0.7 cc envelope volume), high efficiency (>9% electrical-to-optical conversion) and large modulation bandwidth (>100 MHz).
Recent progress in liquid crystal projection displays
NASA Astrophysics Data System (ADS)
Hamada, Hiroshi
1997-05-01
An LC-projector usually contains 3 monochrome TFT-LCDs with a 3-channel dichroic system or a single TFT-LCD with a micro color filter. The liquid crystal operation mode adopted in a TFT-LCD is TN. The optical throughput of an LC-projector is reduced by a pair of polarizers, an aperture ratio of a TFT- LCD and a color filter in a single-LCD projector. In order to eliminate absorption loss by a color filter, a single LCD projection system which consists of a monochrome LCD with a microlens array and a color splitting system using tilted dichroic mirrors or another optical element such as a holographic optical element or a blazed grating has been developed. And LC rear projection TVs have started to challenge CRT-based rear projection TVs. In addition to this system, new technologies to improve optical throughput have been developed to the practical stage such as an active- matrix-addressed PDLC and a reflective type LCD on a Si-LSI chip. Merits and technical issues of newly developed systems and conventional systems including a-Si TFT-LCDs and p-Si TFT-LCDs are discussed mainly in terms of optical throughput.
Centripetal Force on an Overhead Projector.
ERIC Educational Resources Information Center
Rheam, Harry
1995-01-01
Describes two simple demonstrations of an object moving in a straight line tangent to the circle if centripetal force is removed. Demonstrations use a pie plate and petri dish with ball bearings to illustrate the phenomena on an overhead projector. (LZ)
The GB/3D Type Fossils Online Web Portal
NASA Astrophysics Data System (ADS)
McCormick, T.; Howe, M. P.
2013-12-01
Fossils are the remains of once-living organisms that existed and played out their lives in 3-dimensional environments. The information content provided by a 3d representation of a fossil is much greater than that provided by a traditional photograph, and can grab the attention and imagination of the younger and older general public alike. The British Geological Survey has been leading a consortium of UK natural history museums including the Oxford University Museum of Natural History, the Sedgwick Museum Cambridge, the National Museum of Wales Cardiff, and a number of smaller regional British museums to construct a web portal giving access to metadata, high resolution images and interactive 3d models of type fossils from the UK. The web portal at www.3d-fossils.ac.uk was officially launched in August 2013. It can be used to discover metadata describing the provenance, taxonomy, and stratigraphy of the specimens. Zoom-able high resolution digital photographs are available, including for many specimens ';anaglyph' stereo images that can be viewed in 3d using red-cyan stereo spectacles. For many of the specimens interactive 3d models were generated by scanning with portable ';NextEngine 3D HD' 3d scanners. These models can be downloaded in zipped .OBJ and .PLY format from the web portal, or may be viewed and manipulated directly in certain web browsers. The images and scans may be freely downloaded subject to a Creative Commons Attribution ShareAlike Non-Commercial license. There is a simple application programming interface (API) allowing metadata to be downloaded, with links to the images and models, in a standardised format for use in data mash-ups and third party applications. The web portal also hosts ';open educational resources' explaining the process of fossilization and the importance of type specimens in taxonomy, as well as providing introductions to the most important fossil groups. We have experimented with using a 3d printer to create replicas of the fossils which can be used in education and public outreach. The audience for the web portal includes both professional paleontologists and the general public. The professional paleontologist can use the portal to discover the whereabouts of the type material for a taxon they are studying, and can use the pictures and 3d models to assess the completeness and preservation quality of the material. This may reduce or negate the need to send specimens (which are often fragile and always irreplaceable) to researchers through the post, or for researchers to make possibly long, expensive and environmentally damaging journeys to visit far-off collections. We hope that the pictures and 3d models will help to stimulate public interest in paleontology and natural history. The ability to digitally image and scan specimens in 3d enables institutions to have an archive record in case specimens are lost or destroyed by accident or warfare. Recent events in Cairo and Baghdad remind us that museum collections are vulnerable to civil and military strife.
Integral freeform illumination lens design of LED based pico-projector.
Zhao, Shuang; Wang, Kai; Chen, Fei; Qin, Zong; Liu, Sheng
2013-05-01
In this paper, an illumination lens design for a LED-based pico-projector is presented. Different from the traditional illumination systems composed by lens group, the integral illumination lens consists of a total internal reflector (TIR) and a freeform surface. TIR acts as collimation lens and its top surface formed by a freeform surface reshapes the nonuniform circular light pattern generated by TIR to be rectangular and uniform. Diameter and height of the lens are 16 and 10 mm, respectively. An optimization method to deal with the problem of extended light source is also presented in detail in this paper. According to the simulation results of the final optimized lens, 77% (neglecting the effect of polarization) of the power of light source is collected on liquid crystal on silicon panel with a 16∶9 ratio and illumination uniformity achieves 92%.
Full-field 3D shape measurement of specular object having discontinuous surfaces
NASA Astrophysics Data System (ADS)
Zhang, Zonghua; Huang, Shujun; Gao, Nan; Gao, Feng; Jiang, Xiangqian
2017-06-01
This paper presents a novel Phase Measuring Deflectometry (PMD) method to measure specular objects having discontinuous surfaces. A mathematical model is established to directly relate the absolute phase and depth, instead of the phase and gradient. Based on the model, a hardware measuring system has been set up, which consists of a precise translating stage, a projector, a diffuser and a camera. The stage locates the projector and the diffuser together to a known position during measurement. By using the model-based and machine vision methods, system calibration is accomplished to provide the required parameters and conditions. The verification tests are given to evaluate the effectiveness of the developed system. 3D (Three-Dimensional) shapes of a concave mirror and a monolithic multi-mirror array having multiple specular surfaces have been measured. Experimental results show that the proposed method can obtain 3D shape of specular objects having discontinuous surfaces effectively
Inexpensive Monocular Pico-Projector-based Augmented Reality Display for Surgical Microscope
Shi, Chen; Becker, Brian C.; Riviere, Cameron N.
2013-01-01
This paper describes an inexpensive pico-projector-based augmented reality (AR) display for a surgical microscope. The system is designed for use with Micron, an active handheld surgical tool that cancels hand tremor of surgeons to improve microsurgical accuracy. Using the AR display, virtual cues can be injected into the microscope view to track the movement of the tip of Micron, show the desired position, and indicate the position error. Cues can be used to maintain high performance by helping the surgeon to avoid drifting out of the workspace of the instrument. Also, boundary information such as the view range of the cameras that record surgical procedures can be displayed to tell surgeons the operation area. Furthermore, numerical, textual, or graphical information can be displayed, showing such things as tool tip depth in the work space and on/off status of the canceling function of Micron. PMID:25264542
NASA Astrophysics Data System (ADS)
Finster, Felix; Murro, Simone; Röken, Christian
2016-07-01
We give a non-perturbative construction of the fermionic projector in Minkowski space coupled to a time-dependent external potential which is smooth and decays faster than quadratically for large times. The weak and strong mass oscillation properties are proven. We show that the integral kernel of the fermionic projector is of the Hadamard form, provided that the time integral of the spatial sup-norm of the potential satisfies a suitable bound. This gives rise to an algebraic quantum field theory of Dirac fields in an external potential with a distinguished pure quasi-free Hadamard state.
NASA Astrophysics Data System (ADS)
Erickson, Ricky A.; Moren, Stephen E.; Skalka, Marion S.
1998-07-01
Providing a flexible and reliable source of IR target imagery is absolutely essential for operation of an IR Scene Projector in a hardware-in-the-loop simulation environment. The Kinetic Kill Vehicle Hardware-in-the-Loop Simulator (KHILS) at Eglin AFB provides the capability, and requisite interfaces, to supply target IR imagery to its Wideband IR Scene Projector (WISP) from three separate sources at frame rates ranging from 30 - 120 Hz. Video can be input from a VCR source at the conventional 30 Hz frame rate. Pre-canned digital imagery and test patterns can be downloaded into stored memory from the host processor and played back as individual still frames or movie sequences up to a 120 Hz frame rate. Dynamic real-time imagery to the KHILS WISP projector system, at a 120 Hz frame rate, can be provided from a Silicon Graphics Onyx computer system normally used for generation of digital IR imagery through a custom CSA-built interface which is available for either the SGI/DVP or SGI/DD02 interface port. The primary focus of this paper is to describe our technical approach and experience in the development of this unique SGI computer and WISP projector interface.
Considerations in Using Computer for Presentation.
ERIC Educational Resources Information Center
Lee, Shih-chung
1997-01-01
Addresses issues to consider in conducting computer presentations. Discusses presentation devices--television, multiscan capable monitor, LCD (liquid crystal display) panel with overhead projector, and video/RGB (red, green, blue) projector; lighting; audience size; and types of presentations--fast/short time multimedia presentations, oral and…
Spectroscopy on the Overhead Projector.
ERIC Educational Resources Information Center
Solomon, Sally; And Others
1994-01-01
Any overhead projector easily can be converted into a simple spectrometer by placing a piece of diffraction grating over the projecting lens. A detailed description of the apparatus and suggested spectroscopy experiments are included. Demonstrations can utilize solutions of cobalt chloride, potassium permanganate, potassium dichromate, or…
NASA Astrophysics Data System (ADS)
Scopatz, Stephen D.; Mendez, Michael; Trent, Randall
2015-05-01
The projection of controlled moving targets is key to the quantitative testing of video capture and post processing for Motion Imagery. This presentation will discuss several implementations of target projectors with moving targets or apparent moving targets creating motion to be captured by the camera under test. The targets presented are broadband (UV-VIS-IR) and move in a predictable, repeatable and programmable way; several short videos will be included in the presentation. Among the technical approaches will be targets that move independently in the camera's field of view, as well targets that change size and shape. The development of a rotating IR and VIS 4 bar target projector with programmable rotational velocity and acceleration control for testing hyperspectral cameras is discussed. A related issue for motion imagery is evaluated by simulating a blinding flash which is an impulse of broadband photons in fewer than 2 milliseconds to assess the camera's reaction to a large, fast change in signal. A traditional approach of gimbal mounting the camera in combination with the moving target projector is discussed as an alternative to high priced flight simulators. Based on the use of the moving target projector several standard tests are proposed to provide a corresponding test to MTF (resolution), SNR and minimum detectable signal at velocity. Several unique metrics are suggested for Motion Imagery including Maximum Velocity Resolved (the measure of the greatest velocity that is accurately tracked by the camera system) and Missing Object Tolerance (measurement of tracking ability when target is obscured in the images). These metrics are applicable to UV-VIS-IR wavelengths and can be used to assist in camera and algorithm development as well as comparing various systems by presenting the exact scenes to the cameras in a repeatable way.
Development of infrared scene projectors for testing fire-fighter cameras
NASA Astrophysics Data System (ADS)
Neira, Jorge E.; Rice, Joseph P.; Amon, Francine K.
2008-04-01
We have developed two types of infrared scene projectors for hardware-in-the-loop testing of thermal imaging cameras such as those used by fire-fighters. In one, direct projection, images are projected directly into the camera. In the other, indirect projection, images are projected onto a diffuse screen, which is then viewed by the camera. Both projectors use a digital micromirror array as the spatial light modulator, in the form of a Micromirror Array Projection System (MAPS) engine having resolution of 800 x 600 with mirrors on a 17 micrometer pitch, aluminum-coated mirrors, and a ZnSe protective window. Fire-fighter cameras are often based upon uncooled microbolometer arrays and typically have resolutions of 320 x 240 or lower. For direct projection, we use an argon-arc source, which provides spectral radiance equivalent to a 10,000 Kelvin blackbody over the 7 micrometer to 14 micrometer wavelength range, to illuminate the micromirror array. For indirect projection, an expanded 4 watt CO II laser beam at a wavelength of 10.6 micrometers illuminates the micromirror array and the scene formed by the first-order diffracted light from the array is projected onto a diffuse aluminum screen. In both projectors, a well-calibrated reference camera is used to provide non-uniformity correction and brightness calibration of the projected scenes, and the fire-fighter cameras alternately view the same scenes. In this paper, we compare the two methods for this application and report on our quantitative results. Indirect projection has an advantage of being able to more easily fill the wide field of view of the fire-fighter cameras, which typically is about 50 degrees. Direct projection more efficiently utilizes the available light, which will become important in emerging multispectral and hyperspectral applications.
Efficiency enhancement of liquid crystal projection displays using light recycle technology
NASA Technical Reports Server (NTRS)
Wang, Y.
2002-01-01
A new technology developed at JPL using low absorption color filters with polarization and color recycle system, is able to enhance efficiency of a single panel liquid crytal display (LCD) projector to the same efficiency of a 3 panel LCD projector.
Effects of mold design of aspheric projector lens for head up display
NASA Astrophysics Data System (ADS)
Chen, Chao-Chang A.; Tang, Jyun-Cing; Teng, Lin-Ming
2010-08-01
This paper investigates the mold design and related effects on an aspheric projector lens for Head Up Display (HUD) with injection molding process. Injection flow analysis with a commercial software, Moldex3D has been used to simulate this projector lens for filling, packing, shrinkage, and flow-induced residual stress. This projector lens contains of variant thickness due to different aspheric design on both surfaces. Defects may be induced as the melt front from the gate into the cavity with jet-flow phenomenon, short shot, weld line, and even shrinkage. Thus, this paper performs a gate design to find the significant parameters including injection velocity, melt temperature, and mold temperature. After simulation by the Moldex3D, gate design for the final assembly of Head Up Display (HUD) has been obtained and then experimental tests have been proceeded for verification of short-shot, weight variation, and flow-induced stress. Moreover, warpage analysis of the Head Up Display (HUD) can be integrated with the optical design specification in future work.
Aliev, Ali E; Mayo, Nathanael K; Baughman, Ray H; Avirovik, Dragan; Priya, Shashank; Zarnetske, Michael R; Blottman, John B
2014-10-10
Carbon nanotube (CNT) aerogel sheets produce smooth-spectra sound over a wide frequency range (1-10(5) Hz) by means of thermoacoustic (TA) sound generation. Protective encapsulation of CNT sheets in inert gases between rigid vibrating plates provides resonant features for the TA sound projector and attractive performance at needed low frequencies. Energy conversion efficiencies in air of 2% and 10% underwater, which can be enhanced by further increasing the modulation temperature. Using a developed method for accurate temperature measurements for the thin aerogel CNT sheets, heat dissipation processes, failure mechanisms, and associated power densities are investigated for encapsulated multilayered CNT TA heaters and related to the thermal diffusivity distance when sheet layers are separated. Resulting thermal management methods for high applied power are discussed and deployed to construct efficient and tunable underwater sound projector for operation at relatively low frequencies, 10 Hz-10 kHz. The optimal design of these TA projectors for high-power SONAR arrays is discussed.
Projection display technology and product trends
NASA Astrophysics Data System (ADS)
Kahn, Frederic J.
1999-05-01
Major technology and market trends that could generate a 20 billion dollar electronic projector market by 2010 are reviewed in the perspective of recent product introductions. A log linear analysis shows that the light outputs of benchmark transportable data video projectors have increased at a rate of almost 90 percent per year since 1993. The list prices of these same projectors have decreased at a rate of over 40 percent per year. The tradeoffs of light output vs. resolution and weight are illustrated. Recent trends in projector efficacy vs. year are discussed. Lumen output per dollar of list price is shown to be a useful market metric. Continued technical advances and innovations including higher throughput light valve technologies with integrated drivers, brighter light source, field sequential color, integrated- and micro-optical components, and aerospace materials are likely to sustain these trends. The new technologies will enable projection displays for entertainment and computer applications with unprecedented levels of performance, compactness, and cost-effectiveness.
NASA Astrophysics Data System (ADS)
Wang, Xicheng; Gao, Jiaobo; Wu, Jianghui; Li, Jianjun; Cheng, Hongliang
2017-02-01
Recently, hyperspectral image projectors (HIP) have been developed in the field of remote sensing. For the advanced performance of system-level validation, target detection and hyperspectral image calibration, HIP has great possibility of development in military, medicine, commercial and so on. HIP is based on the digital micro-mirror device (DMD) and projection technology, which is capable to project arbitrary programmable spectra (controlled by PC) into the each pixel of the IUT1 (instrument under test), such that the projected image could simulate realistic scenes that hyperspectral image could be measured during its use and enable system-level performance testing and validation. In this paper, we built a visible hyperspectral image projector also called the visible target simulator with double DMDs, which the first DMD is used to product the selected monochromatic light from the wavelength of 410 to 720 um, and the light come to the other one. Then we use computer to load image of realistic scenes to the second DMD, so that the target condition and background could be project by the second DMD with the selected monochromatic light. The target condition can be simulated and the experiment could be controlled and repeated in the lab, making the detector instrument could be tested in the lab. For the moment, we make the focus on the spectral engine design include the optical system, research of DMD programmable spectrum and the spectral resolution of the selected spectrum. The detail is shown.
ERIC Educational Resources Information Center
Ioannou, Andri; Vasiliou, Christina; Zaphiris, Panayiotis
2016-01-01
In this study, we enhanced a problem-based learning (PBL) environment with affordable, everyday technologies that can be found in most university classrooms (e.g., projectors, tablets, students' own smartphones, traditional paper-pencil, and Facebook). The study was conducted over a 3-year period, with 60 postgraduate learners in a human-computer…
Computational imaging with a single-pixel detector and a consumer video projector
NASA Astrophysics Data System (ADS)
Sych, D.; Aksenov, M.
2018-02-01
Single-pixel imaging is a novel rapidly developing imaging technique that employs spatially structured illumination and a single-pixel detector. In this work, we experimentally demonstrate a fully operating modular single-pixel imaging system. Light patterns in our setup are created with help of a computer-controlled digital micromirror device from a consumer video projector. We investigate how different working modes and settings of the projector affect the quality of reconstructed images. We develop several image reconstruction algorithms and compare their performance for real imaging. Also, we discuss the potential use of the single-pixel imaging system for quantum applications.
A Formulation of Quantum Field Theory Realizing a Sea of Interacting Dirac Particles
NASA Astrophysics Data System (ADS)
Finster, Felix
2011-08-01
In this survey article, we explain a few ideas behind the fermionic projector approach and summarize recent results which clarify the connection to quantum field theory. The fermionic projector is introduced, which describes the physical system by a collection of Dirac states, including the states of the Dirac sea. Formulating the interaction by an action principle for the fermionic projector, we obtain a consistent description of interacting quantum fields which reproduces the results of perturbative quantum field theory. We find a new mechanism for the generation of boson masses and obtain small corrections to the field equations which violate causality.
Overhead Projector Demonstrations: Some Ideas from the Past.
ERIC Educational Resources Information Center
Kolb, Doris
1987-01-01
Describes nine chemistry demonstrations that can be done using an overhead projector. Includes demonstrations on common ion effect, crystal formation from supersaturated solutions, making iron positive with nitric acid, optical activity, carbon dioxide in human breath, amphoteric hydroxides, the surface tension of mercury, and natural acid-base…
ERIC Educational Resources Information Center
Gould, Mauri
1975-01-01
Describes assembly of a moderately priced synchronized projector and cassette tape recorder using a single channel recorder with a tuned amplifier to separate voice and control tones. Construction requires familiarity with transistors and use of an oscilloscope with an audio signal generator. A picture as well as schematics is provided. (GH)
The CloudBoard Research Platform: an interactive whiteboard for corporate users
NASA Astrophysics Data System (ADS)
Barrus, John; Schwartz, Edward L.
2013-03-01
Over one million interactive whiteboards (IWBs) are sold annually worldwide, predominantly for classroom use with few sales for corporate use. Unmet needs for IWB corporate use were investigated and the CloudBoard Research Platform (CBRP) was developed to investigate and test technology for meeting these needs. The CBRP supports audio conferencing with shared remote drawing activity, casual capture of whiteboard activity for long-term storage and retrieval, use of standard formats such as PDF for easy import of documents via the web and email and easy export of documents. Company RFID badges and key fobs provide secure access to documents at the board and automatic logout occurs after a period of inactivity. Users manage their documents with a web browser. Analytics and remote device management is provided for administrators. The IWB hardware consists of off-the-shelf components (a Hitachi UST Projector, SMART Technologies, Inc. IWB hardware, Mac Mini, Polycom speakerphone, etc.) and a custom occupancy sensor. The three back-end servers provide the web interface, document storage, stroke and audio streaming. Ease of use, security, and robustness sufficient for internal adoption was achieved. Five of the 10 boards installed at various Ricoh sites have been in daily or weekly use for the past year and total system downtime was less than an hour in 2012. Since CBRP was installed, 65 registered users, 9 of whom use the system regularly, have created over 2600 documents.
Uniqueness of thermodynamic projector and kinetic basis of molecular individualism
NASA Astrophysics Data System (ADS)
Gorban, Alexander N.; Karlin, Iliya V.
2004-05-01
Three results are presented: First, we solve the problem of persistence of dissipation for reduction of kinetic models. Kinetic equations with thermodynamic Lyapunov functions are studied. Uniqueness of the thermodynamic projector is proven: There exists only one projector which transforms any vector field equipped with the given Lyapunov function into a vector field with the same Lyapunov function for a given anzatz manifold which is not tangent to the Lyapunov function levels. Second, we use the thermodynamic projector for developing the short memory approximation and coarse-graining for general nonlinear dynamic systems. We prove that in this approximation the entropy production increases. ( The theorem about entropy overproduction.) In example, we apply the thermodynamic projector to derive the equations of reduced kinetics for the Fokker-Planck equation. A new class of closures is developed, the kinetic multipeak polyhedra. Distributions of this type are expected in kinetic models with multidimensional instability as universally as the Gaussian distribution appears for stable systems. The number of possible relatively stable states of a nonequilibrium system grows as 2 m, and the number of macroscopic parameters is in order mn, where n is the dimension of configuration space, and m is the number of independent unstable directions in this space. The elaborated class of closures and equations pretends to describe the effects of “molecular individualism”. This is the third result.
Looking At Display Technologies
ERIC Educational Resources Information Center
Bull, Glen; Bull, Gina
2005-01-01
A projection system in a classroom with an Internet connection provides a window on the world. Until recently, projectors were expensive and difficult to maintain. Technological advances have resulted in solid-state projectors that require little maintenance and cost no more than a computer. Adding a second or third computer to a classroom…
A Simple Polarimeter and Experiments Utilizing an Overhead Projector.
ERIC Educational Resources Information Center
Dorn, H. C.; And Others
1984-01-01
Although polarimeters that illustrate rotation of plane-polarized light by chiral solutions have been previously described, the polarimeter described in this paper has certain advantages when used in conjunction with an overhead projector. Instructions for constructing this polarimeter and its use in demonstrating the optical activity of sugars…
Viewing Vertical Objects with an Overhead Projector.
ERIC Educational Resources Information Center
Wild, R. L.
1988-01-01
Discusses the use of an overhead projector for the deflection of a vertical image to a screen. Describes three demonstrations: magnetizing of a steel ball bearing and paper clip; convection currents of a hot liquid within a cold liquid; and oscillation of concentrated salt solution into fresh water. (YP)
Optical projectors simulate human eyes to establish operator's field of view
NASA Technical Reports Server (NTRS)
Beam, R. A.
1966-01-01
Device projects visual pattern limits of the field of view of an operator as his eyes are directed at a given point on a control panel. The device, which consists of two projectors, provides instant evaluation of visual ability at a point on a panel.
The Overhead Projector in the Mathematics Classroom.
ERIC Educational Resources Information Center
Lenchner, George
The first section of this pamphlet illustrates and describes the overhead projector, and discusses several of its advantages over other projection devises, including its simplicity of operation, conservation of class time, dynamic effects, image size, etc. The second section describes in some detail materials and methods used to make visuals, then…
Use of high-radiant flux, high-resolution DMD light engines in industrial applications
NASA Astrophysics Data System (ADS)
Müller, Alexandra; Ram, Surinder
2014-03-01
The field of application of industrial projectors is growing day by day. New Digital Micromirror Device (DMD) - based applications like 3D printing, 3D scanning, Printed Circuit Board (PCB) board printing and others are getting more and more sophisticated. The technical demands for the projection system are rising as new and more stringent requirements appear. The specification for industrial projection systems differ substantially from the ones of business and home beamers. Beamers are designed to please the human eye. Bright colors and image enhancement are far more important than uniformity of the illumination or image distortion. The human eye, followed by the processing of the brain can live with quite high intensity variations on the screen and image distortion. On the other hand, a projector designed for use in a specialized field has to be tailored regarding its unique requirements in order to make no quality compromises. For instance, when the image is projected onto a light sensitive resin, a good uniformity of the illumination is crucial for good material hardening (curing) results. The demands on the hardware and software are often very challenging. In the following we will review some parameters that have to be considered carefully for the design of industrial projectors in order to get the optimum result without compromises.
A projective surgical navigation system for cancer resection
NASA Astrophysics Data System (ADS)
Gan, Qi; Shao, Pengfei; Wang, Dong; Ye, Jian; Zhang, Zeshu; Wang, Xinrui; Xu, Ronald
2016-03-01
Near infrared (NIR) fluorescence imaging technique can provide precise and real-time information about tumor location during a cancer resection surgery. However, many intraoperative fluorescence imaging systems are based on wearable devices or stand-alone displays, leading to distraction of the surgeons and suboptimal outcome. To overcome these limitations, we design a projective fluorescence imaging system for surgical navigation. The system consists of a LED excitation light source, a monochromatic CCD camera, a host computer, a mini projector and a CMOS camera. A software program is written by C++ to call OpenCV functions for calibrating and correcting fluorescence images captured by the CCD camera upon excitation illumination of the LED source. The images are projected back to the surgical field by the mini projector. Imaging performance of this projective navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex-vivo chicken tissue model. In all the experiments, the projected images by the projector match well with the locations of fluorescence emission. Our experimental results indicate that the proposed projective navigation system can be a powerful tool for pre-operative surgical planning, intraoperative surgical guidance, and postoperative assessment of surgical outcome. We have integrated the optoelectronic elements into a compact and miniaturized system in preparation for further clinical validation.
A Simple Classroom Demonstration of Natural Convection
ERIC Educational Resources Information Center
Wheeler, Dean R.
2005-01-01
This article explains a simple way to demonstrate natural convection, such as from a lit candle, in the classroom using an overhead projector. The demonstration is based on the principle of schlieren imaging, commonly used to visualize variations in density for gas flows.
The Lenz Vector and Orbital Analog Computers
ERIC Educational Resources Information Center
Harter, W. G.
1976-01-01
Describes a single geometrical diagram based on the Lenz vector which shows the qualitative and quantitative features of all three types of Coulomb orbits. Explains the use of a simple analog computer with an overhead projector to demonstrate many of these effects. (Author/CP)
Khadra, Christelle; Ballard, Ariane; Déry, Johanne; Paquin, David; Fortin, Jean-Simon; Perreault, Isabelle; Labbe, David R; Hoffman, Hunter G; Bouchard, Stéphane; LeMay, Sylvie
2018-01-01
Virtual reality (VR) is a non-pharmacological method to distract from pain during painful procedures. However, it was never tested in young children with burn injuries undergoing wound care. We aimed to assess the feasibility and acceptability of the study process and the use of VR for procedural pain management. From June 2016 to January 2017, we recruited children from 2 months to 10 years of age with burn injuries requiring a hydrotherapy session in a pediatric university teaching hospital in Montreal. Each child received the projector-based VR intervention in addition to the standard pharmacological treatment. Data on intervention and study feasibility and acceptability in addition to measures on pain (Face, Legs, Activity, Cry, Consolability scale), baseline (Modified Smith Scale) and procedural (Procedure Behavior Check List) anxiety, comfort (OCCEB-BECCO [behavioral observational scale of comfort level for child burn victims]), and sedation (Ramsay Sedation Scale) were collected before, during, and after the procedure. Data analyses included descriptive and non-parametric inferential statistics. We recruited 15 children with a mean age of 2.2±2.1 years and a mean total body surface area of 5% (±4). Mean pain score during the procedure was low (2.9/10, ±3), as was the discomfort level (2.9/10, ±2.8). Most children were cooperative, oriented, and calm. Assessing anxiety was not feasible with our sample of participants. The prototype did not interfere with the procedure and was considered useful for procedural pain management by most health care professionals. The projector-based VR is a feasible and acceptable intervention for procedural pain management in young children with burn injuries. A larger trial with a control group is required to assess its efficacy.
NASA Astrophysics Data System (ADS)
Picard, Francis; Ilias, Samir; Asselin, Daniel; Boucher, Marc-André; Duchesne, François; Jacob, Michel; Larouche, Carl; Vachon, Carl; Niall, Keith K.; Jerominek, Hubert
2011-02-01
A MEMS based technology for projection display is reviewed. This technology relies on mechanically flexible and reflective microbridges made of aluminum alloy. A linear array of such micromirrors is combined with illumination and Schlieren optics to produce a pixels line. Each microbridge in the array is individually controlled using electrostatic actuation to adjust the pixels intensities. Results of the simulation, fabrication and characterization of these microdevices are presented. Activation voltages below 250 V with response times below 10 μs were obtained for 25 μm × 25 μm micromirrors. With appropriate actuation voltage waveforms, response times of 5 μs and less are achievable. A damage threshold of the mirrors above 8 kW/cm2 has been evaluated. Development of the technology has produced projector engines demonstrating this light modulation principle. The most recent of these engines is DVI compatible and displays VGA video streams at 60 Hz. Recently applications have emerged that impose more stringent requirements on the dimensions of the MEMS array and associated optical system. This triggered a scale down study to evaluate the minimum micromirror size achievable, the impact of this reduced size on the damage threshold and the achievable minimum size of the associated optical system. Preliminary results of this scale down study are reported. FRAM with active surface as small as 5 μm × 5 μm have been investigated. Simulations have shown that such micromirrors could be activated with 107 V to achieve f-number of 1.25. The damage threshold has been estimated for various FRAM sizes. Finally, design of a conceptual miniaturized projector based on 1000×1 array of 5 μm × 5 μm micromirrors is presented. The volume of this projector concept is about 12 cm3.
Khadra, Christelle; Ballard, Ariane; Déry, Johanne; Paquin, David; Fortin, Jean-Simon; Perreault, Isabelle; Labbe, David R; Hoffman, Hunter G; Bouchard, Stéphane
2018-01-01
Background Virtual reality (VR) is a non-pharmacological method to distract from pain during painful procedures. However, it was never tested in young children with burn injuries undergoing wound care. Aim We aimed to assess the feasibility and acceptability of the study process and the use of VR for procedural pain management. Methods From June 2016 to January 2017, we recruited children from 2 months to 10 years of age with burn injuries requiring a hydrotherapy session in a pediatric university teaching hospital in Montreal. Each child received the projector-based VR intervention in addition to the standard pharmacological treatment. Data on intervention and study feasibility and acceptability in addition to measures on pain (Face, Legs, Activity, Cry, Consolability scale), baseline (Modified Smith Scale) and procedural (Procedure Behavior Check List) anxiety, comfort (OCCEB-BECCO [behavioral observational scale of comfort level for child burn victims]), and sedation (Ramsay Sedation Scale) were collected before, during, and after the procedure. Data analyses included descriptive and non-parametric inferential statistics. Results We recruited 15 children with a mean age of 2.2±2.1 years and a mean total body surface area of 5% (±4). Mean pain score during the procedure was low (2.9/10, ±3), as was the discomfort level (2.9/10, ±2.8). Most children were cooperative, oriented, and calm. Assessing anxiety was not feasible with our sample of participants. The prototype did not interfere with the procedure and was considered useful for procedural pain management by most health care professionals. Conclusion The projector-based VR is a feasible and acceptable intervention for procedural pain management in young children with burn injuries. A larger trial with a control group is required to assess its efficacy. PMID:29491717
Scheins, J J; Vahedipour, K; Pietrzyk, U; Shah, N J
2015-12-21
For high-resolution, iterative 3D PET image reconstruction the efficient implementation of forward-backward projectors is essential to minimise the calculation time. Mathematically, the projectors are summarised as a system response matrix (SRM) whose elements define the contribution of image voxels to lines-of-response (LORs). In fact, the SRM easily comprises billions of non-zero matrix elements to evaluate the tremendous number of LORs as provided by state-of-the-art PET scanners. Hence, the performance of iterative algorithms, e.g. maximum-likelihood-expectation-maximisation (MLEM), suffers from severe computational problems due to the intensive memory access and huge number of floating point operations. Here, symmetries occupy a key role in terms of efficient implementation. They reduce the amount of independent SRM elements, thus allowing for a significant matrix compression according to the number of exploitable symmetries. With our previous work, the PET REconstruction Software TOolkit (PRESTO), very high compression factors (>300) are demonstrated by using specific non-Cartesian voxel patterns involving discrete polar symmetries. In this way, a pre-calculated memory-resident SRM using complex volume-of-intersection calculations can be achieved. However, our original ray-driven implementation suffers from addressing voxels, projection data and SRM elements in disfavoured memory access patterns. As a consequence, a rather limited numerical throughput is observed due to the massive waste of memory bandwidth and inefficient usage of cache respectively. In this work, an advantageous symmetry-driven evaluation of the forward-backward projectors is proposed to overcome these inefficiencies. The polar symmetries applied in PRESTO suggest a novel organisation of image data and LOR projection data in memory to enable an efficient single instruction multiple data vectorisation, i.e. simultaneous use of any SRM element for symmetric LORs. In addition, the calculation time is further reduced by using simultaneous multi-threading (SMT). A global speedup factor of 11 without SMT and above 100 with SMT has been achieved for the improved CPU-based implementation while obtaining equivalent numerical results.
NASA Astrophysics Data System (ADS)
Scheins, J. J.; Vahedipour, K.; Pietrzyk, U.; Shah, N. J.
2015-12-01
For high-resolution, iterative 3D PET image reconstruction the efficient implementation of forward-backward projectors is essential to minimise the calculation time. Mathematically, the projectors are summarised as a system response matrix (SRM) whose elements define the contribution of image voxels to lines-of-response (LORs). In fact, the SRM easily comprises billions of non-zero matrix elements to evaluate the tremendous number of LORs as provided by state-of-the-art PET scanners. Hence, the performance of iterative algorithms, e.g. maximum-likelihood-expectation-maximisation (MLEM), suffers from severe computational problems due to the intensive memory access and huge number of floating point operations. Here, symmetries occupy a key role in terms of efficient implementation. They reduce the amount of independent SRM elements, thus allowing for a significant matrix compression according to the number of exploitable symmetries. With our previous work, the PET REconstruction Software TOolkit (PRESTO), very high compression factors (>300) are demonstrated by using specific non-Cartesian voxel patterns involving discrete polar symmetries. In this way, a pre-calculated memory-resident SRM using complex volume-of-intersection calculations can be achieved. However, our original ray-driven implementation suffers from addressing voxels, projection data and SRM elements in disfavoured memory access patterns. As a consequence, a rather limited numerical throughput is observed due to the massive waste of memory bandwidth and inefficient usage of cache respectively. In this work, an advantageous symmetry-driven evaluation of the forward-backward projectors is proposed to overcome these inefficiencies. The polar symmetries applied in PRESTO suggest a novel organisation of image data and LOR projection data in memory to enable an efficient single instruction multiple data vectorisation, i.e. simultaneous use of any SRM element for symmetric LORs. In addition, the calculation time is further reduced by using simultaneous multi-threading (SMT). A global speedup factor of 11 without SMT and above 100 with SMT has been achieved for the improved CPU-based implementation while obtaining equivalent numerical results.
ERIC Educational Resources Information Center
Bull, Glen; Garofalo, Joe
2006-01-01
In higher education, the number of computer projectors in classrooms has doubled every year for the past five years. A similar trend in K?12 education is occurring now that capable classroom projectors have become available for less than $1,000. At the same time, large-screen displays are becoming common in society; a trend being acceleration by a…
Using the 16MM. Stop-Frame Projector to Teach Film Technique.
ERIC Educational Resources Information Center
Head, James
1969-01-01
English is concerned with language experience, and because much of today's "language" is experienced through electronic media--television, movies, radio--film courses fall within the English curriculum. A stop-frame projector is essential for classroom analysis of such film devices as framing, establishing shots, and scene composition. Framing is…
Launcher and Transparent Air Table for Use with Overhead Projector
ERIC Educational Resources Information Center
Carr, H. Y.; and others
1969-01-01
Describes an apparatus designed for quantitative demonstrations of collision experiments. The apparatus consists of a transparent air table and a launching device for projecting two objects simultaneously. It may be used with an overhead projector. The apparatus won third prize in Demonstration Lecture Apparatus in the A.A.P.T. Apparatus…
Perturbative description of the fermionic projector: Normalization, causality, and Furry's theorem
NASA Astrophysics Data System (ADS)
Finster, Felix; Tolksdorf, Jürgen
2014-05-01
The causal perturbation expansion of the fermionic projector is performed with a contour integral method. Different normalization conditions are analyzed. It is shown that the corresponding light-cone expansions are causal in the sense that they only involve bounded line integrals. For the resulting loop diagrams we prove a generalized Furry theorem.
ERIC Educational Resources Information Center
Montgomery, Malcolm
2008-01-01
As technology and teaching requirements continue to evolve, one would think the choice of which data projector to buy would be easier because there now are more products with more capabilities. Yet just the opposite is true: The sheer number of projectors and myriad combinations of available features can be overwhelming, making it really tough to…
Dissolving Carboxylic Acids and Primary Amines on the Overhead Projector
ERIC Educational Resources Information Center
Solomon, Sally D.; Rutkowsky, Susan A.
2010-01-01
Liquid carboxylic acids (or primary amines) with limited solubility in water are dissolved by addition of aqueous sodium hydroxide (or hydrochloric acid) on the stage of an overhead projector using simple glassware and very small quantities of chemicals. This effective and colorful demonstration can be used to accompany discussions of the…
Geography via the Overhead Projector: Do It This Way, 7.
ERIC Educational Resources Information Center
Best, Thomas D.
This booklet is designed to assist teachers in their use of overhead projectors when teaching geography. With the overhead technique, relationships among patterns can be suggested bit by bit on inexpensive, easily prepared overlays that are projected to sizes appropriate for a particular instructional situation. A general discussion of the…
ERIC Educational Resources Information Center
Domermuth, David
2005-01-01
This article provides a description of an affordable, smart classroom built for the Technology Department at Appalachian State university. The system consists of three basic components: a home theater combo, a tablet PC, and a digital projector, costing a total of $7,300, or $8,800 if a podium, screen, and projector mount are purchased. The…
Beamforming using subspace estimation from a diagonally averaged sample covariance.
Quijano, Jorge E; Zurk, Lisa M
2017-08-01
The potential benefit of a large-aperture sonar array for high resolution target localization is often challenged by the lack of sufficient data required for adaptive beamforming. This paper introduces a Toeplitz-constrained estimator of the clairvoyant signal covariance matrix corresponding to multiple far-field targets embedded in background isotropic noise. The estimator is obtained by averaging along subdiagonals of the sample covariance matrix, followed by covariance extrapolation using the method of maximum entropy. The sample covariance is computed from limited data snapshots, a situation commonly encountered with large-aperture arrays in environments characterized by short periods of local stationarity. Eigenvectors computed from the Toeplitz-constrained covariance are used to construct signal-subspace projector matrices, which are shown to reduce background noise and improve detection of closely spaced targets when applied to subspace beamforming. Monte Carlo simulations corresponding to increasing array aperture suggest convergence of the proposed projector to the clairvoyant signal projector, thereby outperforming the classic projector obtained from the sample eigenvectors. Beamforming performance of the proposed method is analyzed using simulated data, as well as experimental data from the Shallow Water Array Performance experiment.
Image system for three dimensional, 360 DEGREE, time sequence surface mapping of moving objects
Lu, Shin-Yee
1998-01-01
A three-dimensional motion camera system comprises a light projector placed between two synchronous video cameras all focused on an object-of-interest. The light projector shines a sharp pattern of vertical lines (Ronchi ruling) on the object-of-interest that appear to be bent differently to each camera by virtue of the surface shape of the object-of-interest and the relative geometry of the cameras, light projector and object-of-interest Each video frame is captured in a computer memory and analyzed. Since the relative geometry is known and the system pre-calibrated, the unknown three-dimensional shape of the object-of-interest can be solved for by matching the intersections of the projected light lines with orthogonal epipolar lines corresponding to horizontal rows in the video camera frames. A surface reconstruction is made and displayed on a monitor screen. For 360.degree. all around coverage of theobject-of-interest, two additional sets of light projectors and corresponding cameras are distributed about 120.degree. apart from one another.
Image system for three dimensional, 360{degree}, time sequence surface mapping of moving objects
Lu, S.Y.
1998-12-22
A three-dimensional motion camera system comprises a light projector placed between two synchronous video cameras all focused on an object-of-interest. The light projector shines a sharp pattern of vertical lines (Ronchi ruling) on the object-of-interest that appear to be bent differently to each camera by virtue of the surface shape of the object-of-interest and the relative geometry of the cameras, light projector and object-of-interest. Each video frame is captured in a computer memory and analyzed. Since the relative geometry is known and the system pre-calibrated, the unknown three-dimensional shape of the object-of-interest can be solved for by matching the intersections of the projected light lines with orthogonal epipolar lines corresponding to horizontal rows in the video camera frames. A surface reconstruction is made and displayed on a monitor screen. For 360{degree} all around coverage of the object-of-interest, two additional sets of light projectors and corresponding cameras are distributed about 120{degree} apart from one another. 20 figs.
Invalid-point removal based on epipolar constraint in the structured-light method
NASA Astrophysics Data System (ADS)
Qi, Zhaoshuai; Wang, Zhao; Huang, Junhui; Xing, Chao; Gao, Jianmin
2018-06-01
In structured-light measurement, there unavoidably exist many invalid points caused by shadows, image noise and ambient light. According to the property of the epipolar constraint, because the retrieved phase of the invalid point is inaccurate, the corresponding projector image coordinate (PIC) will not satisfy the epipolar constraint. Based on this fact, a new invalid-point removal method based on the epipolar constraint is proposed in this paper. First, the fundamental matrix of the measurement system is calculated, which will be used for calculating the epipolar line. Then, according to the retrieved phase map of the captured fringes, the PICs of each pixel are retrieved. Subsequently, the epipolar line in the projector image plane of each pixel is obtained using the fundamental matrix. The distance between the corresponding PIC and the epipolar line of a pixel is defined as the invalidation criterion, which quantifies the satisfaction degree of the epipolar constraint. Finally, all pixels with a distance larger than a certain threshold are removed as invalid points. Experiments verified that the method is easy to implement and demonstrates better performance than state-of-the-art measurement systems.
Color image quality in projection displays: a case study
NASA Astrophysics Data System (ADS)
Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter
2005-01-01
Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjovik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them therefore harder to predict.
Color image quality in projection displays: a case study
NASA Astrophysics Data System (ADS)
Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter
2004-10-01
Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjøvik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them therefore harder to predict.
Density functional theory calculations of 95Mo NMR parameters in solid-state compounds.
Cuny, Jérôme; Furet, Eric; Gautier, Régis; Le Pollès, Laurent; Pickard, Chris J; d'Espinose de Lacaillerie, Jean-Baptiste
2009-12-21
The application of periodic density functional theory-based methods to the calculation of (95)Mo electric field gradient (EFG) and chemical shift (CS) tensors in solid-state molybdenum compounds is presented. Calculations of EFG tensors are performed using the projector augmented-wave (PAW) method. Comparison of the results with those obtained using the augmented plane wave + local orbitals (APW+lo) method and with available experimental values shows the reliability of the approach for (95)Mo EFG tensor calculation. CS tensors are calculated using the recently developed gauge-including projector augmented-wave (GIPAW) method. This work is the first application of the GIPAW method to a 4d transition-metal nucleus. The effects of ultra-soft pseudo-potential parameters, exchange-correlation functionals and structural parameters are precisely examined. Comparison with experimental results allows the validation of this computational formalism.
Structured light system calibration method with optimal fringe angle.
Li, Beiwen; Zhang, Song
2014-11-20
For structured light system calibration, one popular approach is to treat the projector as an inverse camera. This is usually performed by projecting horizontal and vertical sequences of patterns to establish one-to-one mapping between camera points and projector points. However, for a well-designed system, either horizontal or vertical fringe images are not sensitive to depth variation and thus yield inaccurate mapping. As a result, the calibration accuracy is jeopardized if a conventional calibration method is used. To address this limitation, this paper proposes a novel calibration method based on optimal fringe angle determination. Experiments demonstrate that our calibration approach can increase the measurement accuracy up to 38% compared to the conventional calibration method with a calibration volume of 300(H) mm×250(W) mm×500(D) mm.
A dual-waveband dynamic IR scene projector based on DMD
NASA Astrophysics Data System (ADS)
Hu, Yu; Zheng, Ya-wei; Gao, Jiao-bo; Sun, Ke-feng; Li, Jun-na; Zhang, Lei; Zhang, Fang
2016-10-01
Infrared scene simulation system can simulate multifold objects and backgrounds to perform dynamic test and evaluate EO detecting system in the hardware in-the-loop test. The basic structure of a dual-waveband dynamic IR scene projector was introduced in the paper. The system's core device is an IR Digital Micro-mirror Device (DMD) and the radiant source is a mini-type high temperature IR plane black-body. An IR collimation optical system which transmission range includes 3-5μm and 8-12μm is designed as the projection optical system. Scene simulation software was developed with Visual C++ and Vega soft tools and a software flow chart was presented. The parameters and testing results of the system were given, and this system was applied with satisfying performance in an IR imaging simulation testing.
Using the Overhead Projector as a Light Source for Physics Demonstrations
ERIC Educational Resources Information Center
Mak, Se-Yuen
2006-01-01
This article illustrates how the overhead projector can be used as a light source in some peculiar ways for physics demonstrations. Five examples are included: (1) Study of chromatic aberration; (2) Making giant Newton's rings; (3) Comparison of the rate of heat absorption by different surfaces; (4) Demonstration of greenhouse effect; and (5)…
The Use of the Overhead Projector in Teaching Composition.
ERIC Educational Resources Information Center
Bissex, Henry
The overhead projector, used as a controllable blackboard or bulletin board in the teaching of writing, extends the range of teaching techniques so that an instructor may (1) prepare, in advance, handwritten sheets of film--test questions, pupils' sentences, quotations, short poems--to be shown in any order or form; (2) use pictures, graphics, or…
Overhead Projector Spectrum of Polymethine Dye: A Physical Chemistry Demonstration.
ERIC Educational Resources Information Center
Solomon, Sally; Hur, Chinhyu
1995-01-01
Encourages the incorporation into lecture of live experiments that can be predicted or interpreted with abstract models. A demonstration is described where the position of the predominant peak of 1,1'-diethyl-4,4'-cyanine iodide is measured in class using an overhead projector spectrometer, then predicted using the model of a particle in a…
E-Learning Technologies and Adult Education in Nigeria
ERIC Educational Resources Information Center
Oguzor, Nkasiobi Silas
2011-01-01
The internet has proved to be one of the greatest learning resources available in the 21st Century. Modern education is becoming progressively more dynamic. Internet has helped man to see the other part of the world at the click of a mouse. Various forms of instructional technologies such as the overhead projector, opaque projector, filmstrip and…
An event database for rotational seismology
NASA Astrophysics Data System (ADS)
Salvermoser, Johannes; Hadziioannou, Celine; Hable, Sarah; Chow, Bryant; Krischer, Lion; Wassermann, Joachim; Igel, Heiner
2016-04-01
The ring laser sensor (G-ring) located at Wettzell, Germany, routinely observes earthquake-induced rotational ground motions around a vertical axis since its installation in 2003. Here we present results from a recently installed event database which is the first that will provide ring laser event data in an open access format. Based on the GCMT event catalogue and some search criteria, seismograms from the ring laser and the collocated broadband seismometer are extracted and processed. The ObsPy-based processing scheme generates plots showing waveform fits between rotation rate and transverse acceleration and extracts characteristic wavefield parameters such as peak ground motions, noise levels, Love wave phase velocities and waveform coherence. For each event, these parameters are stored in a text file (json dictionary) which is easily readable and accessible on the website. The database contains >10000 events starting in 2007 (Mw>4.5). It is updated daily and therefore provides recent events at a time lag of max. 24 hours. The user interface allows to filter events for epoch, magnitude, and source area, whereupon the events are displayed on a zoomable world map. We investigate how well the rotational motions are compatible with the expectations from the surface wave magnitude scale. In addition, the website offers some python source code examples for downloading and processing the openly accessible waveforms.
Sechopoulos, I
2012-06-01
To improve the radiology residents' understanding of medical physics concepts through visualization of physical phenomena. Several medical physics concepts in x-ray transmission imaging are relevant to many radiographic modalities, not only to planar radiography. Therefore, it is important that the diagnostic radiology residents obtain a good understanding of these concepts. However, standard PowerPoint slides or blackboard-based graphical representations are not always effective ways to communicate these novel concepts to the residents. To improve upon the understanding of these concepts, the computer, projector and screen in the lecture room are used as surrogates of an x-ray imaging system. The projector is the source of light (x-rays) with PowerPoint slides defining the pattern emitted (x-ray field) on to the projector screen (detector/monitor). Several different transparencies and acrylic objects are used to demonstrate varied medical physics phenomena relevant to transmission imaging, such as: straight-line travel of electromagnetic radiation; tissue superimposition; object, subject, image and display contrast; linear systems; point spread functions; frequency domain; contrast and modulation transfer functions; quantum and image noise; noise frequency and noise power spectrum; anatomical noise; magnification and geometric unsharpness; inverse square distance relationship; sampling and aliasing; and x-ray scatter. The residents' comprehension and ability to explain these concepts has substantially improved, in addition to their interest in these topics. This was reflected on improved test scores and on anonymous feedback surveys post- lectures. The use of demonstrations that mimic the conditions and physical phenomena found in transmission imaging by taking advantage of the projector and screen together with transparencies and other objects improves the residents' grasp of basic radiographic concepts and promotes live interactions between the residents and the medical physicist. Additional concepts that can be demonstrated in this manner are being sought. © 2012 American Association of Physicists in Medicine.
We Have Met Our Past and Our Future: Thanks for the Walk down Memory Lane
ERIC Educational Resources Information Center
Wiseman, Robert C.
2006-01-01
In this article, the author takes the readers for a walk down memory lane on the use of teaching aids. He shares his experience of the good old days of Audio Visual--opaque projector, motion pictures/films, recorders, and overhead projector. Computers have arrived, and now people can make graphics, pictures, motion pictures, and many different…
ERIC Educational Resources Information Center
Sugimoto, Masanori
2011-01-01
This paper describes a system called GENTORO that uses a robot and a handheld projector for supporting children's storytelling activities. GENTORO differs from many existing systems in that children can make a robot play their own story in a physical space augmented by mixed-reality technologies. Pilot studies have been conducted to clarify the…
ERIC Educational Resources Information Center
Liu, Li-Ying; Cheng, Meng-Tzu
2015-01-01
This study reports on a measurement that is used to investigate interactivity in the classrooms and examines the impact of integrating the interactive projector into middle school science classes on classroom interactivity and students' biology learning. A total of 126 7th grade Taiwanese students were involved in the study and quasi-experimental…
Projector-Camera Systems for Immersive Training
2006-01-01
average to a sequence of 100 captured distortion corrected images. The OpenCV library [ OpenCV ] was used for camera calibration. To correct for...rendering application [Treskunov, Pair, and Swartout, 2004]. It was transposed to take into account different matrix conventions between OpenCV and...Screen Imperfections. Proc. Workshop on Projector-Camera Systems (PROCAMS), Nice, France, IEEE. OpenCV : Open Source Computer Vision. [Available
The Fermionic Projector, entanglement and the collapse of the wave function
NASA Astrophysics Data System (ADS)
Finster, Felix
2011-07-01
After a brief introduction to the fermionic projector approach, we review how entanglement and second quantized bosonic and fermionic fields can be described in this framework. The constructions are discussed with regard to decoherence phenomena and the measurement problem. We propose a mechanism leading to the collapse of the wave function in the quantum mechanical measurement process.
Projection display technologies for the new millennium
NASA Astrophysics Data System (ADS)
Kahn, Frederic J.
2000-04-01
Although analog CRTs continue to enable most of the world's electronic projection displays such as US consumer rear projection televisions, discrete pixel (digital) active matrix LCD and DLP reflective mirror array projectors have rapidly created large nonconsumer markets--primarily for business. Recent advances in image quality, compactness and cost effectiveness of digital projectors have the potential to revolutionize major consumer and entertainment markets as well. Digital penetration of the mainstream consumer projection TV market will begin in the hear 2000. By 2005 digital projection HDTVs could take the major share of the consumer HDTV projection market. Digital projection is expected to dominate both the consumer HDTV and the cinema market by 2010, resulting in potential shipments for all projection markets exceeding 10 M units per year. Digital projection is improving at a rate 10X faster than analog CRT projectors and 5X faster than PDP flat panels. Continued rapid improvement of digital projection is expected due to its relative immaturity and due to the wide diversity of technological improvements being pursued. Key technology enablers are the imaging panels, light sources and micro-optics. Market shares of single panel projectors, MEMs panels, LCOS panels and low T p-Si TFT LCD panel variants are expected to increase.
Method calibration of the model 13145 infrared target projectors
NASA Astrophysics Data System (ADS)
Huang, Jianxia; Gao, Yuan; Han, Ying
2014-11-01
The SBIR Model 13145 Infrared Target Projectors ( The following abbreviation Evaluation Unit ) used for characterizing the performances of infrared imaging system. Test items: SiTF, MTF, NETD, MRTD, MDTD, NPS. Infrared target projectors includes two area blackbodies, a 12 position target wheel, all reflective collimator. It provide high spatial frequency differential targets, Precision differential targets imaged by infrared imaging system. And by photoelectricity convert on simulate signal or digital signal. Applications software (IR Windows TM 2001) evaluate characterizing the performances of infrared imaging system. With regards to as a whole calibration, first differently calibration for distributed component , According to calibration specification for area blackbody to calibration area blackbody, by means of to amend error factor to calibration of all reflective collimator, radiance calibration of an infrared target projectors using the SR5000 spectral radiometer, and to analyze systematic error. With regards to as parameter of infrared imaging system, need to integrate evaluation method. According to regulation with -GJB2340-1995 General specification for military thermal imaging sets -testing parameters of infrared imaging system, the results compare with results from Optical Calibration Testing Laboratory . As a goal to real calibration performances of the Evaluation Unit.
NASA Astrophysics Data System (ADS)
Rössler, Tomáš; Hrabovský, Miroslav; Pluháček, František
2005-08-01
The cotyle implantate is abraded in the body of patient and its shape changes. Information about the magnitude of abrasion is contained in the result contour map of the implantate. The locations and dimensions of abraded areas can be computed from the contours deformation. The method called the single-projector moire topography was used for the contour lines determination. The theoretical description of method is given at first. The design of the experimental set-up follows. The light grating projector was developed to realize the periodic structure on the measured surface. The method of fringe-shifting was carried out to increase the data quantity. The description of digital processing applied to the moire grating images is introduced at the end together with the examples of processed images.
Quantum teleportation and Birman-Murakami-Wenzl algebra
NASA Astrophysics Data System (ADS)
Zhang, Kun; Zhang, Yong
2017-02-01
In this paper, we investigate the relationship of quantum teleportation in quantum information science and the Birman-Murakami-Wenzl (BMW) algebra in low-dimensional topology. For simplicity, we focus on the two spin-1/2 representation of the BMW algebra, which is generated by both the Temperley-Lieb projector and the Yang-Baxter gate. We describe quantum teleportation using the Temperley-Lieb projector and the Yang-Baxter gate, respectively, and study teleportation-based quantum computation using the Yang-Baxter gate. On the other hand, we exploit the extended Temperley-Lieb diagrammatical approach to clearly show that the tangle relations of the BMW algebra have a natural interpretation of quantum teleportation. Inspired by this interpretation, we construct a general representation of the tangle relations of the BMW algebra and obtain interesting representations of the BMW algebra. Therefore, our research sheds a light on a link between quantum information science and low-dimensional topology.
A low-cost and portable realization on fringe projection three-dimensional measurement
NASA Astrophysics Data System (ADS)
Xiao, Suzhi; Tao, Wei; Zhao, Hui
2015-12-01
Fringe projection three-dimensional measurement is widely applied in a wide range of industrial application. The traditional fringe projection system has the disadvantages of high expense, big size, and complicated calibration requirements. In this paper we introduce a low-cost and portable realization on three-dimensional measurement with Pico projector. It has the advantages of low cost, compact physical size, and flexible configuration. For the proposed fringe projection system, there is no restriction to camera and projector's relative alignment on parallelism and perpendicularity for installation. Moreover, plane-based calibration method is adopted in this paper that avoids critical requirements on calibration system such as additional gauge block or precise linear z stage. What is more, error sources existing in the proposed system are introduced in this paper. The experimental results demonstrate the feasibility of the proposed low cost and portable fringe projection system.
Sekihara, K; Poeppel, D; Marantz, A; Koizumi, H; Miyashita, Y
1997-09-01
This paper proposes a method of localizing multiple current dipoles from spatio-temporal biomagnetic data. The method is based on the multiple signal classification (MUSIC) algorithm and is tolerant of the influence of background brain activity. In this method, the noise covariance matrix is estimated using a portion of the data that contains noise, but does not contain any signal information. Then, a modified noise subspace projector is formed using the generalized eigenvectors of the noise and measured-data covariance matrices. The MUSIC localizer is calculated using this noise subspace projector and the noise covariance matrix. The results from a computer simulation have verified the effectiveness of the method. The method was then applied to source estimation for auditory-evoked fields elicited by syllable speech sounds. The results strongly suggest the method's effectiveness in removing the influence of background activity.
Pindelska, Edyta; Szeleszczuk, Lukasz; Pisklak, Dariusz Maciej; Majka, Zbigniew; Kolodziejski, Waclaw
2015-07-01
Tiotropium bromide is an anticholinergic bronchodilator used in the management of chronic obstructive pulmonary disease. The crystal structures of this compound and its monohydrate have been previously solved and published. However, in this paper, we showed that those structures contain some major errors. Our methodology based on combination of the solid-state nuclear magnetic resonance (NMR) spectroscopy and quantum mechanical gauge-including projector-augmented wave (GIPAW) calculations of NMR shielding constants enabled us to correct those errors and obtain reliable structures of the studied compounds. It has been proved that such approach can be used not only to perform the structural analysis of a drug substance and to identify its polymorphs, but also to verify and optimize already existing crystal structures. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Application of LC and LCoS in Multispectral Polarized Scene Projector (MPSP)
NASA Astrophysics Data System (ADS)
Yu, Haiping; Guo, Lei; Wang, Shenggang; Lippert, Jack; Li, Le
2017-02-01
A Multispectral Polarized Scene Projector (MPSP) had been developed in the short-wave infrared (SWIR) regime for the test & evaluation (T&E) of spectro-polarimetric imaging sensors. This MPSP generates multispectral and hyperspectral video images (up to 200 Hz) with 512×512 spatial resolution with active spatial, spectral, and polarization modulation with controlled bandwidth. It projects input SWIR radiant intensity scenes from stored memory with user selectable wavelength and bandwidth, as well as polarization states (six different states) controllable on a pixel level. The spectral contents are implemented by a tunable filter with variable bandpass built based on liquid crystal (LC) material, together with one passive visible and one passive SWIR cholesteric liquid crystal (CLC) notch filters, and one switchable CLC notch filter. The core of the MPSP hardware is the liquid-crystal-on-silicon (LCoS) spatial light modulators (SLMs) for intensity control and polarization modulation.
LEDs on the threshold for use in projection systems: challenges, limitations and applications
NASA Astrophysics Data System (ADS)
Moffat, Bryce Anton
2006-02-01
The use of coloured LEDs as light sources in digital projectors depends on an optimal combination of optical, electrical and thermal parameters to meet the performance and cost targets needed to enable these products to compete in the marketplace. This paper describes the system design methodology for a digital micromirror display (DMD) based optical engine using LEDs as the light source, starting at the basic physical and geometrical parameters of the DMD and other optical elements through characterization of the LEDs to optimizing the system performance by determining optimal driving conditions. The main challenge in using LEDs is the luminous flux density, which is just at the threshold of acceptance in projection systems and thus only a fully optimized optical system with a uniformly bright set of LEDs can be used. As a result of this work we have developed two applications: a compact pocket projector and a rear projection television.
On orthogonal projectors induced by compact groups and Haar measures
NASA Astrophysics Data System (ADS)
Niezgoda, Marek
2008-02-01
We study the difference of two orthogonal projectors induced by compact groups of linear operators acting on a vector space. An upper bound for the difference is derived using the Haar measures of the groups. A particular attention is paid to finite groups. Some applications are given for complex matrices and unitarily invariant norms. Majorization inequalities of Fan and Hoffmann and of Causey are rediscovered.
ERIC Educational Resources Information Center
Flory, John
Although there have been great developments in motion picture technology, such as super 8mm film, magnetic sound, low cost color film, simpler projectors and movie cameras, and cartridge-loading projectors, there is still only limited use of audiovisual materials in the classroom today. This paper suggests some of the possible reasons for the lack…
The Principle of the Fermionic Projector: An Approach for Quantum Gravity?
NASA Astrophysics Data System (ADS)
Finster, Felix
In this short article we introduce the mathematical framework of the principle of the fermionic projector and set up a variational principle in discrete space-time. The underlying physical principles are discussed. We outline the connection to the continuum theory and state recent results. In the last two sections, we speculate on how it might be possible to describe quantum gravity within this framework.
Perturbative quantum field theory in the framework of the fermionic projector
NASA Astrophysics Data System (ADS)
Finster, Felix
2014-04-01
We give a microscopic derivation of perturbative quantum field theory, taking causal fermion systems and the framework of the fermionic projector as the starting point. The resulting quantum field theory agrees with standard quantum field theory on the tree level and reproduces all bosonic loop diagrams. The fermion loops are described in a different formalism in which no ultraviolet divergences occur.
NASA Astrophysics Data System (ADS)
Martin, Alexandre; Torrent, Marc; Caracas, Razvan
2015-03-01
A formulation of the response of a system to strain and electric field perturbations in the pseudopotential-based density functional perturbation theory (DFPT) has been proposed by D.R Hamman and co-workers. It uses an elegant formalism based on the expression of DFT total energy in reduced coordinates, the key quantity being the metric tensor and its first and second derivatives. We propose to extend this formulation to the Projector Augmented-Wave approach (PAW). In this context, we express the full elastic tensor including the clamped-atom tensor, the atomic-relaxation contributions (internal stresses) and the response to electric field change (piezoelectric tensor and effective charges). With this we are able to compute the elastic tensor for all materials (metals and insulators) within a fully analytical formulation. The comparison with finite differences calculations on simple systems shows an excellent agreement. This formalism has been implemented in the plane-wave based DFT ABINIT code. We apply it to the computation of elastic properties and seismic-wave velocities of iron with impurity elements. By analogy with the materials contained in meteorites, tested impurities are light elements (H, O, C, S, Si).
A Lagrange-type projector on the real line
NASA Astrophysics Data System (ADS)
Mastroianni, G.; Notarangelo, I.
2010-01-01
We introduce an interpolation process based on some of the zeros of the m th generalized Freud polynomial. Convergence results and error estimates are given. In particular we show that, in some important function spaces, the interpolating polynomial behaves like the best approximation. Moreover the stability and the convergence of some quadrature rules are proved.
A Protein in the Palm of Your Hand through Augmented Reality
ERIC Educational Resources Information Center
Berry, Colin; Board, Jason
2014-01-01
Understanding of proteins and other biological macromolecules must be based on an appreciation of their 3-dimensional shape and the fine details of their structure. Conveying these details in a clear and stimulating fashion can present challenges using conventional approaches and 2-dimensional monitors and projectors. Here we describe a method for…
Ubiquitous Presenter: A Tablet PC-Based System to Support Instructors and Students
ERIC Educational Resources Information Center
Price, Edward; Simon, Beth
2009-01-01
Digital lecturing systems (computer and projector, often with PowerPoint) offer physics instructors the ability to incorporate graphics and the power to share and reuse materials. But these systems do a poor job of supporting interaction in the classroom. For instance, with digital presentation systems, instructors have limited ability to…
A portable foot-parameter-extracting system
NASA Astrophysics Data System (ADS)
Zhang, MingKai; Liang, Jin; Li, Wenpan; Liu, Shifan
2016-03-01
In order to solve the problem of automatic foot measurement in garment customization, a new automatic footparameter- extracting system based on stereo vision, photogrammetry and heterodyne multiple frequency phase shift technology is proposed and implemented. The key technologies applied in the system are studied, including calibration of projector, alignment of point clouds, and foot measurement. Firstly, a new projector calibration algorithm based on plane model has been put forward to get the initial calibration parameters and a feature point detection scheme of calibration board image is developed. Then, an almost perfect match of two clouds is achieved by performing a first alignment using the Sampled Consensus - Initial Alignment algorithm (SAC-IA) and refining the alignment using the Iterative Closest Point algorithm (ICP). Finally, the approaches used for foot-parameterextracting and the system scheme are presented in detail. Experimental results show that the RMS error of the calibration result is 0.03 pixel and the foot parameter extracting experiment shows the feasibility of the extracting algorithm. Compared with the traditional measurement method, the system can be more portable, accurate and robust.
Viewing zone duplication of multi-projection 3D display system using uniaxial crystal.
Lee, Chang-Kun; Park, Soon-Gi; Moon, Seokil; Lee, Byoungho
2016-04-18
We propose a novel multiplexing technique for increasing the viewing zone of a multi-view based multi-projection 3D display system by employing double refraction in uniaxial crystal. When linearly polarized images from projector pass through the uniaxial crystal, two possible optical paths exist according to the polarization states of image. Therefore, the optical paths of the image could be changed, and the viewing zone is shifted in a lateral direction. The polarization modulation of the image from a single projection unit enables us to generate two viewing zones at different positions. For realizing full-color images at each viewing zone, a polarization-based temporal multiplexing technique is adopted with a conventional polarization switching device of liquid crystal (LC) display. Through experiments, a prototype of a ten-view multi-projection 3D display system presenting full-colored view images is implemented by combining five laser scanning projectors, an optically clear calcite (CaCO3) crystal, and an LC polarization rotator. For each time sequence of temporal multiplexing, the luminance distribution of the proposed system is measured and analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu Feipeng; Shi Hongjian; Bai Pengxiang
In fringe projection, the CCD camera and the projector are often placed at equal height. In this paper, we will study the calibration of an unequal arrangement of the CCD camera and the projector. The principle of fringe projection with two-dimensional digital image correlation to acquire the profile of object surface is described in detail. By formula derivation and experiment, the linear relationship between the out-of-plane calibration coefficient and the y coordinate is clearly found. To acquire the three-dimensional (3D) information of an object correctly, this paper presents an effective calibration method with linear least-squares fitting, which is very simplemore » in principle and calibration. Experiments are implemented to validate the availability and reliability of the calibration method.« less
Projection Mapping User Interface for Disabled People
Simutis, Rimvydas; Maskeliūnas, Rytis
2018-01-01
Difficulty in communicating is one of the key challenges for people suffering from severe motor and speech disabilities. Often such person can communicate and interact with the environment only using assistive technologies. This paper presents a multifunctional user interface designed to improve communication efficiency and person independence. The main component of this interface is a projection mapping technique used to highlight objects in the environment. Projection mapping makes it possible to create a natural augmented reality information presentation method. The user interface combines a depth sensor and a projector to create camera-projector system. We provide a detailed description of camera-projector system calibration procedure. The described system performs tabletop object detection and automatic projection mapping. Multiple user input modalities have been integrated into the multifunctional user interface. Such system can be adapted to the needs of people with various disabilities. PMID:29686827
Projection Mapping User Interface for Disabled People.
Gelšvartas, Julius; Simutis, Rimvydas; Maskeliūnas, Rytis
2018-01-01
Difficulty in communicating is one of the key challenges for people suffering from severe motor and speech disabilities. Often such person can communicate and interact with the environment only using assistive technologies. This paper presents a multifunctional user interface designed to improve communication efficiency and person independence. The main component of this interface is a projection mapping technique used to highlight objects in the environment. Projection mapping makes it possible to create a natural augmented reality information presentation method. The user interface combines a depth sensor and a projector to create camera-projector system. We provide a detailed description of camera-projector system calibration procedure. The described system performs tabletop object detection and automatic projection mapping. Multiple user input modalities have been integrated into the multifunctional user interface. Such system can be adapted to the needs of people with various disabilities.
A method for the real-time construction of a full parallax light field
NASA Astrophysics Data System (ADS)
Tanaka, Kenji; Aoki, Soko
2006-02-01
We designed and implemented a light field acquisition and reproduction system for dynamic objects called LiveDimension, which serves as a 3D live video system for multiple viewers. The acquisition unit consists of circularly arranged NTSC cameras surrounding an object. The display consists of circularly arranged projectors and a rotating screen. The projectors are constantly projecting images captured by the corresponding cameras onto the screen. The screen rotates around an in-plane vertical axis at a sufficient speed so that it faces each of the projectors in sequence. Since the Lambertian surfaces of the screens are covered by light-collimating plastic films with vertical louver patterns that are used for the selection of appropriate light rays, viewers can only observe images from a projector located in the same direction as the viewer. Thus, the dynamic view of an object is dependent on the viewer's head position. We evaluated the system by projecting both objects and human figures and confirmed that the entire system can reproduce light fields with a horizontal parallax to display video sequences of 430x770 pixels at a frame rate of 45 fps. Applications of this system include product design reviews, sales promotion, art exhibits, fashion shows, and sports training with form checking.
Flexible high-resolution display systems for the next generation of radiology reading rooms
NASA Astrophysics Data System (ADS)
Caban, Jesus J.; Wood, Bradford J.; Park, Adrian
2007-03-01
A flexible, scalable, high-resolution display system is presented to support the next generation of radiology reading rooms or interventional radiology suites. The project aims to create an environment for radiologists that will simultaneously facilitate image interpretation, analysis, and understanding while lowering visual and cognitive stress. Displays currently in use present radiologists with technical challenges to exploring complex datasets that we seek to address. These include resolution and brightness, display and ambient lighting differences, and degrees of complexity in addition to side-by-side comparison of time-variant and 2D/3D images. We address these issues through a scalable projector-based system that uses our custom-designed geometrical and photometrical calibration process to create a seamless, bright, high-resolution display environment that can reduce the visual fatigue commonly experienced by radiologists. The system we have designed uses an array of casually aligned projectors to cooperatively increase overall resolution and brightness. Images from a set of projectors in their narrowest zoom are combined at a shared projection surface, thus increasing the global "pixels per inch" (PPI) of the display environment. Two primary challenges - geometric calibration and photometric calibration - remained to be resolved before our high-resolution display system could be used in a radiology reading room or procedure suite. In this paper we present a method that accomplishes those calibrations and creates a flexible high-resolution display environment that appears seamless, sharp, and uniform across different devices.
A Visual Aid for Teaching Basic Concepts of Soil-Water Physics.
ERIC Educational Resources Information Center
Eshel, Amram
1997-01-01
Presents a visual aid designed to generate an image of water movement among soil particles using an overhead projector to teach the physical phenomena related to water status and water movement in the soil. Utilizes a base plate of thin transparent plastic, opaque plastic sheets, a plate of glass, and a colored aqueous solution. (AIM)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-13
... science-based human health assessments to support the Agency's regulatory activities. The IRIS database... May 21, 2009, to develop human health assessments for inclusion in the IRIS database. The purpose of... if you will need audio-visual aid (e.g., lap top computer and slide projector). In general, each...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
... found in the environment. Through the IRIS Program, EPA provides the highest quality science-based human... for the external review draft human health assessment titled, ``Toxicological Review of n-Butanol: In... will need audio-visual equipment (e.g., laptop computer and slide projector). In general, each...
NASA Astrophysics Data System (ADS)
Alexandrou, Constantia; Athenodorou, Andreas; Cichy, Krzysztof; Constantinou, Martha; Horkel, Derek P.; Jansen, Karl; Koutsou, Giannis; Larkin, Conor
2018-04-01
We compare lattice QCD determinations of topological susceptibility using a gluonic definition from the gradient flow and a fermionic definition from the spectral-projector method. We use ensembles with dynamical light, strange and charm flavors of maximally twisted mass fermions. For both definitions of the susceptibility we employ ensembles at three values of the lattice spacing and several quark masses at each spacing. The data are fitted to chiral perturbation theory predictions with a discretization term to determine the continuum chiral condensate in the massless limit and estimate the overall discretization errors. We find that both approaches lead to compatible results in the continuum limit, but the gluonic ones are much more affected by cutoff effects. This finally yields a much smaller total error in the spectral-projector results. We show that there exists, in principle, a value of the spectral cutoff which would completely eliminate discretization effects in the topological susceptibility.
NASA Astrophysics Data System (ADS)
Vanfleteren, Diederik; Van Neck, Dimitri; Bultinck, Patrick; Ayers, Paul W.; Waroquier, Michel
2012-01-01
A previously introduced partitioning of the molecular one-electron density matrix over atoms and bonds [D. Vanfleteren et al., J. Chem. Phys. 133, 231103 (2010)] is investigated in detail. Orthogonal projection operators are used to define atomic subspaces, as in Natural Population Analysis. The orthogonal projection operators are constructed with a recursive scheme. These operators are chemically relevant and obey a stockholder principle, familiar from the Hirshfeld-I partitioning of the electron density. The stockholder principle is extended to density matrices, where the orthogonal projectors are considered to be atomic fractions of the summed contributions. All calculations are performed as matrix manipulations in one-electron Hilbert space. Mathematical proofs and numerical evidence concerning this recursive scheme are provided in the present paper. The advantages associated with the use of these stockholder projection operators are examined with respect to covalent bond orders, bond polarization, and transferability.
High accuracy LADAR scene projector calibration sensor development
NASA Astrophysics Data System (ADS)
Kim, Hajin J.; Cornell, Michael C.; Naumann, Charles B.; Bowden, Mark H.
2008-04-01
A sensor system for the characterization of infrared laser radar scene projectors has been developed. Available sensor systems do not provide sufficient range resolution to evaluate the high precision LADAR projector systems developed by the U.S. Army Research, Development and Engineering Command (RDECOM) Aviation and Missile Research, Development and Engineering Center (AMRDEC). With timing precision capability to a fraction of a nanosecond, it can confirm the accuracy of simulated return pulses from a nominal range of up to 6.5 km to a resolution of 4cm. Increased range can be achieved through firmware reconfiguration. Two independent amplitude triggers measure both rise and fall time providing a judgment of pulse shape and allowing estimation of the contained energy. Each return channel can measure up to 32 returns per trigger characterizing each return pulse independently. Currently efforts include extending the capability to 8 channels. This paper outlines the development, testing, capabilities and limitations of this new sensor system.
Quality status display for a vibration welding process
Spicer, John Patrick; Abell, Jeffrey A.; Wincek, Michael Anthony; Chakraborty, Debejyo; Bracey, Jennifer; Wang, Hui; Tavora, Peter W.; Davis, Jeffrey S.; Hutchinson, Daniel C.; Reardon, Ronald L.; Utz, Shawn
2017-03-28
A system includes a host machine and a status projector. The host machine is in electrical communication with a collection of sensors and with a welding controller that generates control signals for controlling the welding horn. The host machine is configured to execute a method to thereby process the sensory and control signals, as well as predict a quality status of a weld that is formed using the welding horn, including identifying any suspect welds. The host machine then activates the status projector to illuminate the suspect welds. This may occur directly on the welds using a laser projector, or on a surface of the work piece in proximity to the welds. The system and method may be used in the ultrasonic welding of battery tabs of a multi-cell battery pack in a particular embodiment. The welding horn and welding controller may also be part of the system.
A subjective evaluation of high-chroma color with wide color-gamut display
NASA Astrophysics Data System (ADS)
Kishimoto, Junko; Yamaguchi, Masahiro; Ohyama, Nagaaki
2009-01-01
Displays tends to expand its color gamut, such as multi-primary color display, Adobe RGB and so on. Therefore displays got possible to display high chroma colors. However sometimes, we feel unnatural some for the image which only expanded chroma. Appropriate gamut mapping method to expand color gamut is not proposed very much. We are attempting preferred expanded color reproduction on wide color gamut display utilizing high chroma colors effectively. As a first step, we have conducted an experiment to investigate the psychological effect of color schemes including highly saturated colors. We used the six-primary-color projector that we have developed for the presentation of test colors. The six-primary-color projector's gamut volume in CIELAB space is about 1.8 times larger than the normal RGB projector. We conducted a subjective evaluation experiment using the SD (Semantic Differential) technique to find the quantitative psychological effect of high chroma colors.
2013-01-01
Abstract Images are a critical part of the identification process because they enable direct, immediate and relatively unmediated comparisons between a specimen being identified and one or more reference specimens. The Carices Interactive Visual Identification Key (CIVIK) is a novel tool for identification of North American Carex species, the largest vascular plant genus in North America, and two less numerous closely-related genera, Cymophyllus and Kobresia. CIVIK incorporates 1288 high-resolution tiled image sets that allow users to zoom in to view minute structures that are crucial at times for identification in these genera. Morphological data are derived from the earlier Carex Interactive Identification Key (CIIK) which in turn used data from the Flora of North America treatments. In this new iteration, images can be viewed in a grid or histogram format, allowing multiple representations of data. In both formats the images are fully zoomable. PMID:24723777
Design of a Day/Night Lunar Rover
NASA Astrophysics Data System (ADS)
Berkelman, Peter; Easudes, Jesse; Martin, Martin C.; Rollins, Eric; Silberman, Jack; Chen, Mei; Hancock, John; Mor, Andrew B.; Sharf, Alex; Warren, Tom; Bapna, Deepak
1995-06-01
The pair of lunar rovers discussed in this report will return video and state data to various ventures, including theme park and marketing concerns, science agencies, and educational institutions. The greatest challenge accepted by the design team was to enable operations throughout the extremely cold and dark lunar night, an unprecedented goal in planetary exploration. This is achieved through the use of the emerging technology of Alkali Metal Thermal to Electric Converters (AMTEC), provided with heat from a innovative beta-decay heat source, Krypton-85 gas. Although previous space missions have returned still images, our design will convey panoramic video from a ring of cameras around the rover. A six-wheel rocker bogie mechanism is implemented to propel the rover. The rovers will also provide the ability to safeguard their operation to allow untrained members of the general public to drive the vehicle. Additionally, scientific exploration and educational outreach will be supported with a user operable, steerable and zoomable camera.
NASA Astrophysics Data System (ADS)
Banegas, Frederic; Michelucci, Dominique; Roelens, Marc; Jaeger, Marc
1999-05-01
We present a robust method for automatically constructing an ellipsoidal skeleton (e-skeleton) from a set of 3D points taken from NMR or TDM images. To ensure steadiness and accuracy, all points of the objects are taken into account, including the inner ones, which is different from the existing techniques. This skeleton will be essentially useful for object characterization, for comparisons between various measurements and as a basis for deformable models. It also provides good initial guess for surface reconstruction algorithms. On output of the entire process, we obtain an analytical description of the chosen entity, semantically zoomable (local features only or reconstructed surfaces), with any level of detail (LOD) by discretization step control in voxel or polygon format. This capability allows us to handle objects at interactive frame rates once the e-skeleton is computed. Each e-skeleton is stored as a multiscale CSG implicit tree.
Ward, Jamie; Li, Ryan; Salih, Shireen; Sagiv, Noam
2007-12-01
Recent research has suggested that not all grapheme-colour synaesthetes are alike. One suggestion is that they can be divided, phenomenologically, in terms of whether the colours are experienced in external or internal space (projector-associator distinction). Another suggestion is that they can be divided according to whether it is the perceptual or conceptual attributes of a stimulus that is critical (higher-lower distinction). This study compares the behavioural performance of 7 projector and 7 associator synaesthetes. We demonstrate that this distinction does not map on to behavioural traits expected from the higher-lower distinction. We replicate previous research showing that projectors are faster at naming their synaesthetic colours than veridical colours, and that associators show the reverse profile. Synaesthetes who project colours into external space but not on to the surface of the grapheme behave like associators on this task. In a second task, graphemes presented briefly in the periphery are more likely to elicit reports of colour in projectors than associators, but the colours only tend to be accurate when the grapheme itself is also accurately identified. We propose an alternative model of individual differences in grapheme-colour synaesthesia that emphasises the role of different spatial reference frames in synaesthetic perception. In doing so, we attempt to bring the synaesthesia literature closer to current models of non-synaesthetic perception, attention and binding.
Comparison of three coding strategies for a low cost structure light scanner
NASA Astrophysics Data System (ADS)
Xiong, Hanwei; Xu, Jun; Xu, Chenxi; Pan, Ming
2014-12-01
Coded structure light is widely used for 3D scanning, and different coding strategies are adopted to suit for different goals. In this paper, three coding strategies are compared, and one of them is selected to implement a low cost structure light scanner under the cost of €100. To reach this goal, the projector and the video camera must be the cheapest, which will lead to some problems related to light coding. For a cheapest projector, complex intensity pattern can't be generated; even if it can be generated, it can't be captured by a cheapest camera. Based on Gray code, three different strategies are implemented and compared, called phase-shift, line-shift, and bit-shift, respectively. The bit-shift Gray code is the contribution of this paper, in which a simple, stable light pattern is used to generate dense(mean points distance<0.4mm) and accurate(mean error<0.1mm) results. The whole algorithm details and some example are presented in the papers.
Dual-sensitivity profilometry with defocused projection of binary fringes.
Garnica, G; Padilla, M; Servin, M
2017-10-01
A dual-sensitivity profilometry technique based on defocused projection of binary fringes is presented. Here, two sets of fringe patterns with a sinusoidal profile are produced by applying the same analog low-pass filter (projector defocusing) to binary fringes with a high- and low-frequency spatial carrier. The high-frequency fringes have a binary square-wave profile, while the low-frequency binary fringes are produced with error-diffusion dithering. The binary nature of the binary fringes removes the need for calibration of the projector's nonlinear gamma. Working with high-frequency carrier fringes, we obtain a high-quality wrapped phase. On the other hand, working with low-frequency carrier fringes we found a lower-quality, nonwrapped phase map. The nonwrapped estimation is used as stepping stone for dual-sensitivity temporal phase unwrapping, extending the applicability of the technique to discontinuous (piecewise continuous) surfaces. We are proposing a single defocusing level for faster high- and low-frequency fringe data acquisition. The proposed technique is validated with experimental results.
Optical design of ultrashort throw liquid crystal on silicon projection system
NASA Astrophysics Data System (ADS)
Huang, Jiun-Woei
2017-05-01
An ultrashort throw liquid crystal on silicon (LCoS) projector for home cinema, virtual reality, and automobile heads-up display has been designed and fabricated. To achieve the best performance and highest-quality image, this study aimed to design wide-angle projection optics and optimize the illumination for LCoS. Based on the telecentric lens projection system and optimized Koehler illumination, the optical parameters were calculated. The projector's optical system consisted of a conic aspheric mirror and image optics using either symmetric double Gauss or a large-angle eyepiece to achieve a full projection angle larger than 155 deg. By applying Koehler illumination, image resolution was enhanced and the modulation transfer function of the image in high spatial frequency was increased to form a high-quality illuminated image. The partial coherence analysis verified that the design was capable of 2.5 lps/mm within a 2 m×1.5 m projected image. The throw ratio was less than 0.25 in HD format.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, W.J.; Greene, C.R.; Koski, W.R.
1991-10-01
The report concerns the effects of underwater noise from simulated oil production operations on the movements and behavior of bowhead and white whales migrating around northern Alaska in spring. An underwater sound projector suspended from pack ice was used to introduce recorded drilling noise and other test sounds into leads through the pack ice. These sounds were received and measured at various distances to determine the rate of sound attenuation with distance and frequency. The movements and behavior of bowhead and white whales approaching the operating projector were studied by aircraft- and ice-based observers. Some individuals of both species weremore » observed to approach well within the ensonified area. However, behavioral changes and avoidance reactions were evident when the received sound level became sufficiently high. Reactions to aircraft are also discussed.« less
Glasses-free large size high-resolution three-dimensional display based on the projector array
NASA Astrophysics Data System (ADS)
Sang, Xinzhu; Wang, Peng; Yu, Xunbo; Zhao, Tianqi; Gao, Xing; Xing, Shujun; Yu, Chongxiu; Xu, Daxiong
2014-11-01
Normally, it requires a huge amount of spatial information to increase the number of views and to provide smooth motion parallax for natural three-dimensional (3D) display similar to real life. To realize natural 3D video display without eye-wears, a huge amount of 3D spatial information is normal required. However, minimum 3D information for eyes should be used to reduce the requirements for display devices and processing time. For the 3D display with smooth motion parallax similar to the holographic stereogram, the size the virtual viewing slit should be smaller than the pupil size of eye at the largest viewing distance. To increase the resolution, two glass-free 3D display systems rear and front projection are presented based on the space multiplexing with the micro-projector array and the special designed 3D diffuse screens with the size above 1.8 m× 1.2 m. The displayed clear depths are larger 1.5m. The flexibility in terms of digitized recording and reconstructed based on the 3D diffuse screen relieves the limitations of conventional 3D display technologies, which can realize fully continuous, natural 3-D display. In the display system, the aberration is well suppressed and the low crosstalk is achieved.
NASA Astrophysics Data System (ADS)
Chen, Liangjun; Ni, Kai; Zhou, Qian; Cheng, Xuemin; Ma, Jianshe; Gao, Yuan; Sun, Peng; Li, Yi; Liu, Minxia
2010-11-01
Interactive projection systems based on CCD/CMOS have been greatly developed in recent years. They can locate and trace the movement of a pen equipped with an infrared LED, and displays the user's handwriting or react to the user's operation in real time. However, a major shortcoming is that the location device and the projector are independent with each other, including both the optical system and the control system. This requires construction of two optical systems, calibration of the differences between the projector view and the camera view, and also synchronization between two control systems, etc. In this paper, we introduced a two-dimensional location method based on digital micro-mirror device (DMD). The DMD is used as the display device and the position detector in turn. By serially flipping the micro-mirrors on the DMD according to a specially designed scheme and monitoring the reflected light energy, the image spot of the infrared LED can be quickly located. By using this method, the same optical system as well as the DMD can be multiplexed for projection and location, which will reduce the complexity and cost of the whole system. Furthermore, this method can also achieve high positioning accuracy and sampling rates. The results of location experiments are given.
Huang, Shih-Hao; Yu, Chu-Hung; Chien, Yi-Lung
2015-01-01
We have developed a digital light modulation system that utilizes a modified commercial projector equipped with a laser diode as a light source for quantitative measurements of in vivo tissue oxygenation in an unanesthetized zebrafish embryo via phase-based phosphorescence lifetime detection. The oxygen-sensitive phosphorescent probe (Oxyphor G4) was first inoculated into the bloodstream of 48 h post-fertilization (48 hpf) zebrafish embryos via the circulation valley to rapidly disperse probes throughout the embryo. The unanesthetized zebrafish embryo was introduced into the microfluidic device and immobilized on its lateral side by using a pneumatically actuated membrane. By controlling the illumination pattern on the digital micromirror device in the projector, the modulated excitation light can be spatially projected to illuminate arbitrarily-shaped regions of tissue of interest for in vivo oxygen measurements. We have successfully measured in vivo oxygen changes in the cardiac region and cardinal vein of a 48 hpf zebrafish embryo that experience hypoxia and subsequent normoxic conditions. Our proposed platform provides the potential for the real-time investigation of oxygen distribution in tissue microvasculature that relates to physiological stimulation and diseases in a developing organism. PMID:25856326
An optical watermarking solution for color personal identification pictures
NASA Astrophysics Data System (ADS)
Tan, Yi-zhou; Liu, Hai-bo; Huang, Shui-hua; Sheng, Ben-jian; Pan, Zhong-ming
2009-11-01
This paper presents a new approach for embedding authentication information into image on printed materials based on optical projection technique. Our experimental setup consists of two parts, one is a common camera, and the other is a LCD projector, which project a pattern on personnel's body (especially on the face). The pattern, generated by a computer, act as the illumination light source with sinusoidal distribution and it is also the watermark signal. For a color image, the watermark is embedded into the blue channel. While we take pictures (256×256 and 512×512, 567×390 pixels, respectively), an invisible mark is embedded directly into magnitude coefficients of Discrete Fourier transform (DFT) at exposure moment. Both optical and digital correlation is suitable for detection of this type of watermark. The decoded watermark is a set of concentric circles or sectors in the DFT domain (middle frequencies region) which is robust to photographing, printing and scanning. The unlawful people modify or replace the original photograph, and make fake passport (drivers' license and so on). Experiments show, it is difficult to forge certificates in which a watermark was embedded by our projector-camera combination based on analogue watermark method rather than classical digital method.
MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera
NASA Astrophysics Data System (ADS)
Wang, Hongkai; Stout, David B.; Taschereau, Richard; Gu, Zheng; Vu, Nam T.; Prout, David L.; Chatziioannou, Arion F.
2012-10-01
This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.
MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera.
Wang, Hongkai; Stout, David B; Taschereau, Richard; Gu, Zheng; Vu, Nam T; Prout, David L; Chatziioannou, Arion F
2012-10-07
This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.
A calibration method immune to the projector errors in fringe projection profilometry
NASA Astrophysics Data System (ADS)
Zhang, Ruihua; Guo, Hongwei
2017-08-01
In fringe projection technique, system calibration is a tedious task to establish the mapping relationship between the object depths and the fringe phases. Especially, it is not easy to accurately determine the parameters of the projector in this system, which may induce errors in the measurement results. To solve this problem, this paper proposes a new calibration by using the cross-ratio invariance in the system geometry for determining the phase-to-depth relations. In it, we analyze the epipolar eometry of the fringe projection system. On each epipolar plane, the depth variation along an incident ray induces the pixel movement along the epipolar line on the image plane of the camera. These depth variations and pixel movements can be connected by use of the projective transformations, under which condition the cross-ratio for each of them keeps invariant. Based on this fact, we suggest measuring the depth map by use of this cross-ratio invariance. Firstly, we shift the reference board in its perpendicular direction to three positions with known depths, and measure their phase maps as the reference phase maps; and secondly, when measuring an object, we calculate the object depth at each pixel by equating the cross-ratio of the depths to that of the corresponding pixels having the same phase on the image plane of the camera. This method is immune to the errors sourced from the projector, including the distortions both in the geometric shapes and in the intensity profiles of the projected fringe patterns.The experimental results demonstrate the proposed method to be feasible and valid.
Dhaliwal, Upreet
2007-11-01
To enhance successful communication, medical teachers are increasingly using teaching-learning media. To determine medical students' perception of three such media (blackboard, overhead projector, and slides), and to generate recommendations for their optimal use, a prospective questionnaire-based study was carried out among 7th semester medical students of the University College of Medical Sciences and Guru Teg Bahadur Hospital, Delhi. Students made a forced choice between: (1) The three media on 8 questions regarding their advantages and disadvantages and (2) four aspects of a lecture (teaching-learning media, topic, teacher and time of day) regarding which made the lecture most engaging. Resulting data was analysed by Chi-square and Fisher's exact tests. Chalk and blackboard was rated as best in allowing interaction and helping recall (p<0.001 each). The overhead projector was best in providing information pointwise (p<0.001; 67 students, 89.3%, considered this an advantage). More subject matter could be covered per lecture (p=0.001; 58 students, 77.3%, considered this a disadvantage). Slides were best in imparting clinical details (p=0.004), but were sleep inducing (p<0.001). The teacher's style of instruction was most important in making the lecture engaging (p<0.001). The teacher's role in the learning process is important. Students enjoy the slow pace and interaction allowed by blackboard, pointwise information presented by the overhead projector, and the clinical details a slide can provide. The results suggest that the lecture could best be a combination of two or more teaching-learning media. Students' interaction should be encouraged whatever the media used.
Obstacle Detection and Avoidance of a Mobile Robotic Platform Using Active Depth Sensing
2014-06-01
price of nearly one tenth of a laser range finder, the Xbox Kinect uses an infrared projector and camera to capture images of its environment in three...inception. At the price of nearly one tenth of a laser range finder, the Xbox Kinect uses an infrared projector and camera to capture images of its...cropped between 280 and 480 pixels. ........11 Figure 9. RGB image captured by the camera on the Xbox Kinect. ...............................12 Figure
Polarization measurements made on LFRA and OASIS emitter arrays
NASA Astrophysics Data System (ADS)
Geske, Jon; Sparkman, Kevin; Oleson, Jim; Laveigne, Joe; Sieglinger, Breck; Marlow, Steve; Lowry, Heard; Burns, James
2008-04-01
Polarization is increasingly being considered as a method of discrimination in passive sensing applications. In this paper the degree of polarization of the thermal emission from the emitter arrays of two new Santa Barbara Infrared (SBIR) micro-bolometer resistor array scene projectors was characterized at ambient temperature and at 77 K. The emitter arrays characterized were from the Large Format Resistive Array (LFRA) and the Optimized Arrays for Space-Background Infrared Simulation (OASIS) scene projectors. This paper reports the results of this testing.
NASA Astrophysics Data System (ADS)
Hiremath, Varun; Pope, Stephen B.
2013-04-01
The Rate-Controlled Constrained-Equilibrium (RCCE) method is a thermodynamic based dimension reduction method which enables representation of chemistry involving n s species in terms of fewer n r constraints. Here we focus on the application of the RCCE method to Lagrangian particle probability density function based computations. In these computations, at every reaction fractional step, given the initial particle composition (represented using RCCE), we need to compute the reaction mapping, i.e. the particle composition at the end of the time step. In this work we study three different implementations of RCCE for computing this reaction mapping, and compare their relative accuracy and efficiency. These implementations include: (1) RCCE/TIFS (Trajectory In Full Space): this involves solving a system of n s rate-equations for all the species in the full composition space to obtain the reaction mapping. The other two implementations obtain the reaction mapping by solving a reduced system of n r rate-equations obtained by projecting the n s rate-equations for species evaluated in the full space onto the constrained subspace. These implementations include (2) RCCE: this is the classical implementation of RCCE which uses a direct projection of the rate-equations for species onto the constrained subspace; and (3) RCCE/RAMP (Reaction-mixing Attracting Manifold Projector): this is a new implementation introduced here which uses an alternative projector obtained using the RAMP approach. We test these three implementations of RCCE for methane/air premixed combustion in the partially-stirred reactor with chemistry represented using the n s=31 species GRI-Mech 1.2 mechanism with n r=13 to 19 constraints. We show that: (a) the classical RCCE implementation involves an inaccurate projector which yields large errors (over 50%) in the reaction mapping; (b) both RCCE/RAMP and RCCE/TIFS approaches yield significantly lower errors (less than 2%); and (c) overall the RCCE/TIFS approach is the most accurate, efficient (by orders of magnitude) and robust implementation.
Projection display market trends
NASA Astrophysics Data System (ADS)
Mentley, David E.
1997-05-01
The projection display industry is now a multi-billion dollar market comprising an expanding variety of technologies and applications. Growth is being driven by a combination of high volume consumer products and high value business demand. After many years of marginal, but steady performance improvements, essentially all types of projectors have crossed the threshold of acceptability and are now facing accelerated continuing growth. Overall worldwide unit sales of all types of projection displays for all applications will nearly double from 1.6 million units in 1996 to 2.8 million units in 2002. By value at the end user price, the global projector market will grow modestly from 6.3 billion dollars in 1996 to 7.7 billion dollars in 2002. Consumer television will represent the largest share of unit consumption over this time period; in 1996, this application represents 72 percent of the total unit volume. The second major application category for projection displays is the business or presentation projector, representing only 14 percent of the unit shipment total in 1996, but 50 percent of the value.
Toward the light field display: autostereoscopic rendering via a cluster of projectors.
Yang, Ruigang; Huang, Xinyu; Li, Sifang; Jaynes, Christopher
2008-01-01
Ultimately, a display device should be capable of reproducing the visual effects observed in reality. In this paper we introduce an autostereoscopic display that uses a scalable array of digital light projectors and a projection screen augmented with microlenses to simulate a light field for a given three-dimensional scene. Physical objects emit or reflect light in all directions to create a light field that can be approximated by the light field display. The display can simultaneously provide many viewers from different viewpoints a stereoscopic effect without head tracking or special viewing glasses. This work focuses on two important technical problems related to the light field display; calibration and rendering. We present a solution to automatically calibrate the light field display using a camera and introduce two efficient algorithms to render the special multi-view images by exploiting their spatial coherence. The effectiveness of our approach is demonstrated with a four-projector prototype that can display dynamic imagery with full parallax.
Reporting guide for laser-light shows and displays (21 CFR 1002)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The guide is to be used for reporting laser-light shows or displays incorporating Class IIIb or Class IV lasers only. Separate reports are not required for shows or displays that incorporate Class I, IIa, II, or IIIa laser-projection systems. Such show descriptions must be included in the user instructions and the report for the laser projector. Laser projectors used in any light shows or displays regardless of the class of the projector must be certified by the manufacturer and reported using the guide titled, Guide for Preparing Initial Reports and Model Change Reports on Lasers and Products Containing Lasers, HHSmore » Publication FDA 86-8259. These guides assist manufacturers in providing the information that the Center for Devices and Radiological Health (CDRH) needs to determine how laser-light-shown projections and laser-light shows comply with the Federal standard for laser products (21 CDR 1040.10 and 1040.11) and with the conditions of an approved variance.« less
Liquid crystal light valve technologies for display applications
NASA Astrophysics Data System (ADS)
Kikuchi, Hiroshi; Takizawa, Kuniharu
2001-11-01
The liquid crystal (LC) light valve, which is a spatial light modulator that uses LC material, is a very important device in the area of display development, image processing, optical computing, holograms, etc. In particular, there have been dramatic developments in the past few years in the application of the LC light valve to projectors and other display technologies. Various LC operating modes have been developed, including thin film transistors, MOS-FETs and other active matrix drive techniques to meet the requirements for higher resolution, and substantial improvements have been achieved in the performance of optical systems, resulting in brighter display images. Given this background, the number of applications for the LC light valve has greatly increased. The resolution has increased from QVGA (320 x 240) to QXGA (2048 x 1536) or even super- high resolution of eight million pixels. In the area of optical output, projectors of 600 to 13,000 lm are now available, and they are used for presentations, home theatres, electronic cinema and other diverse applications. Projectors using the LC light valve can display high- resolution images on large screens. They are now expected to be developed further as part of hyper-reality visual systems. This paper provides an overview of the needs for large-screen displays, human factors related to visual effects, the way in which LC light valves are applied to projectors, improvements in moving picture quality, and the results of the latest studies that have been made to increase the quality of images and moving images or pictures.
Projection type transparent 3D display using active screen
NASA Astrophysics Data System (ADS)
Kamoshita, Hiroki; Yendo, Tomohiro
2015-05-01
Equipment to enjoy a 3D image, such as a movie theater, television and so on have been developed many. So 3D video are widely known as a familiar image of technology now. The display representing the 3D image are there such as eyewear, naked-eye, the HMD-type, etc. They has been used for different applications and location. But have not been widely studied for the transparent 3D display. If transparent large 3D display is realized, it is useful to display 3D image overlaid on real scene in some applications such as road sign, shop window, screen in the conference room etc. As a previous study, to produce a transparent 3D display by using a special transparent screen and number of projectors is proposed. However, for smooth motion parallax, many projectors are required. In this paper, we propose a display that has transparency and large display area by time multiplexing projection image in time-division from one or small number of projectors to active screen. The active screen is composed of a number of vertically-long small rotate mirrors. It is possible to realize the stereoscopic viewing by changing the image of the projector in synchronism with the scanning of the beam.3D vision can be realized by light is scanned. Also, the display has transparency, because it is possible to see through the display when the mirror becomes perpendicular to the viewer. We confirmed the validity of the proposed method by using simulation.
OPO-based compact laser projection display
NASA Astrophysics Data System (ADS)
Lee, Dicky; Moulton, Peter F.; Bergstedt, Robert; Flint, Graham W.
2001-09-01
In this paper we discuss our red, green, and blue (RGB) optical parametric oscillator (OPO) based laser projection display. The complete project display consists of two subsystems, the RGB-OPO laser head and the light modulation unit. The RGB lights from rack-mounted laser head are fibers coupled to the projection unit for independent placement. The light source consists of a diode-pumped pump laser and a LBO-based OPO. Based on our Nd:YLF gain module design, the pump laser is frequency doubled to serve as the pump source for the OPO. The unconverted pump power is recycled as the green light for projection. The singly resonant, non- critically phase-matched (NCPM) OPO has, to date, generated 13 W of 898-nm signal power and an estimated 9.3 W of intra- cavity idler power at 1256 nm. With approximately 76% of pump depletion, the power of the residual green light for projection is about 5.8 W. We have extra-cavity doubled the signal to produce approximately 3.5 W of 449-nm blue light and intra-cavity doubled the idler to produce approximately 6 W of 628-nm red light. The OPO-based RGB source generates about 4000 lumens of D65-balanced white light. The overall electrical power on a commercially available JVC's three- panel D-ILA (reflective LCD) projector with the arc-lamp removed and extensive modifications. The projector has a native resolution of 1365 x 1024 and the expected on screen lumens from our laser display is about 1200 lumens.
NASA Astrophysics Data System (ADS)
Duffey, Jason N.; Jones, Brian K.; Loudin, Jeffrey A.; Booth, Joseph J.
1995-03-01
Liquid crystal televisions are popular low-cost spatial light modulators. One LCTV of interest is found in the InFocus TVT-6000 television projector. A wavefront splitting interferometer has been constructed and analyzed for measuring the complex characteristics of these modulators, including phase and amplitude coupling. The results of this evaluation using the TVT-6000 projector drive electronics have been presented in a previous work. This work will present results of the complex characterizations of these modulators using custom drive electronics.
2004-01-01
cooled below –40ºC with the ultra low temperature chiller operating at –50ºC. At these low temperatures, elastomer compounds (i.e. nylon hose and o...projector hardware. Consideration of steel braided Teflon hose or even a thin wall flexible steel hose will be made for future operation of the YUGO...Cajon VCR vacuum port on the bottom of the array using a metal gasket. This change eliminated one elastomer seal that was most likely to fail at low
[A Method for Selecting Self-Adoptive Chromaticity of the Projected Markers].
Zhao, Shou-bo; Zhang, Fu-min; Qu, Xing-hua; Zheng, Shi-wei; Chen, Zhe
2015-04-01
The authors designed a self-adaptive projection system which is composed of color camera, projector and PC. In detail, digital micro-mirror device (DMD) as a spatial light modulator for the projector was introduced in the optical path to modulate the illuminant spectrum based on red, green and blue light emitting diodes (LED). However, the color visibility of active markers is affected by the screen which has unknown reflective spectrum as well. Here active markers are projected spot array. And chromaticity feature of markers is sometimes submerged in similar spectral screen. In order to enhance the color visibility of active markers relative to screen, a method for selecting self-adaptive chromaticity of the projected markers in 3D scanning metrology is described. Color camera with 3 channels limits the accuracy of device characterization. For achieving interconversion of device-independent color space and device-dependent color space, high-dimensional linear model of reflective spectrum was built. Prior training samples provide additional constraints to yield high-dimensional linear model with more than three degrees of freedom. Meanwhile, spectral power distribution of ambient light was estimated. Subsequently, markers' chromaticity in CIE color spaces was selected via maximization principle of Euclidean distance. The setting values of RGB were easily estimated via inverse transform. Finally, we implemented a typical experiment to show the performance of the proposed approach. An 24 Munsell Color Checker was used as projective screen. Color difference in the chromaticity coordinates between the active marker and the color patch was utilized to evaluate the color visibility of active markers relative to the screen. The result comparison between self-adaptive projection system and traditional diode-laser light projector was listed and discussed to highlight advantage of our proposed method.
Exact density functional and wave function embedding schemes based on orbital localization
NASA Astrophysics Data System (ADS)
Hégely, Bence; Nagy, Péter R.; Ferenczy, György G.; Kállay, Mihály
2016-08-01
Exact schemes for the embedding of density functional theory (DFT) and wave function theory (WFT) methods into lower-level DFT or WFT approaches are introduced utilizing orbital localization. First, a simple modification of the projector-based embedding scheme of Manby and co-workers [J. Chem. Phys. 140, 18A507 (2014)] is proposed. We also use localized orbitals to partition the system, but instead of augmenting the Fock operator with a somewhat arbitrary level-shift projector we solve the Huzinaga-equation, which strictly enforces the Pauli exclusion principle. Second, the embedding of WFT methods in local correlation approaches is studied. Since the latter methods split up the system into local domains, very simple embedding theories can be defined if the domains of the active subsystem and the environment are treated at a different level. The considered embedding schemes are benchmarked for reaction energies and compared to quantum mechanics (QM)/molecular mechanics (MM) and vacuum embedding. We conclude that for DFT-in-DFT embedding, the Huzinaga-equation-based scheme is more efficient than the other approaches, but QM/MM or even simple vacuum embedding is still competitive in particular cases. Concerning the embedding of wave function methods, the clear winner is the embedding of WFT into low-level local correlation approaches, and WFT-in-DFT embedding can only be more advantageous if a non-hybrid density functional is employed.
Wang, Zongjie; Abdulla, Raafa; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Kim, Keekyoung
2015-12-22
Bioprinting is a rapidly developing technique for biofabrication. Because of its high resolution and the ability to print living cells, bioprinting has been widely used in artificial tissue and organ generation as well as microscale living cell deposition. In this paper, we present a low-cost stereolithography-based bioprinting system that uses visible light crosslinkable bioinks. This low-cost stereolithography system was built around a commercial projector with a simple water filter to prevent harmful infrared radiation from the projector. The visible light crosslinking was achieved by using a mixture of polyethylene glycol diacrylate (PEGDA) and gelatin methacrylate (GelMA) hydrogel with eosin Y based photoinitiator. Three different concentrations of hydrogel mixtures (10% PEG, 5% PEG + 5% GelMA, and 2.5% PEG + 7.5% GelMA, all w/v) were studied with the presented systems. The mechanical properties and microstructure of the developed bioink were measured and discussed in detail. Several cell-free hydrogel patterns were generated to demonstrate the resolution of the solution. Experimental results with NIH 3T3 fibroblast cells show that this system can produce a highly vertical 3D structure with 50 μm resolution and 85% cell viability for at least five days. The developed system provides a low-cost visible light stereolithography solution and has the potential to be widely used in tissue engineering and bioengineering for microscale cell patterning.
Fast 3D NIR systems for facial measurement and lip-reading
NASA Astrophysics Data System (ADS)
Brahm, Anika; Ramm, Roland; Heist, Stefan; Rulff, Christian; Kühmstedt, Peter; Notni, Gunther
2017-05-01
Structured-light projection is a well-established optical method for the non-destructive contactless three-dimensional (3D) measurement of object surfaces. In particular, there is a great demand for accurate and fast 3D scans of human faces or facial regions of interest in medicine, safety, face modeling, games, virtual life, or entertainment. New developments of facial expression detection and machine lip-reading can be used for communication tasks, future machine control, or human-machine interactions. In such cases, 3D information may offer more detailed information than 2D images which can help to increase the power of current facial analysis algorithms. In this contribution, we present new 3D sensor technologies based on three different methods of near-infrared projection technologies in combination with a stereo vision setup of two cameras. We explain the optical principles of an NIR GOBO projector, an array projector and a modified multi-aperture projection method and compare their performance parameters to each other. Further, we show some experimental measurement results of applications where we realized fast, accurate, and irritation-free measurements of human faces.
Programmable personality interface for the dynamic infrared scene generator (IRSG2)
NASA Astrophysics Data System (ADS)
Buford, James A., Jr.; Mobley, Scott B.; Mayhall, Anthony J.; Braselton, William J.
1998-07-01
As scene generator platforms begin to rely specifically on commercial off-the-shelf (COTS) hardware and software components, the need for high speed programmable personality interfaces (PPIs) are required for interfacing to Infrared (IR) flight computer/processors and complex IR projectors in the hardware-in-the-loop (HWIL) simulation facilities. Recent technological advances and innovative applications of established technologies are beginning to allow development of cost effective PPIs to interface to COTS scene generators. At the U.S. Army Aviation and Missile Command (AMCOM) Missile Research, Development, and Engineering Center (MRDEC) researchers have developed such a PPI to reside between the AMCOM MRDEC IR Scene Generator (IRSG) and either a missile flight computer or the dynamic Laser Diode Array Projector (LDAP). AMCOM MRDEC has developed several PPIs for the first and second generation IRSGs (IRSG1 and IRSG2), which are based on Silicon Graphics Incorporated (SGI) Onyx and Onyx2 computers with Reality Engine 2 (RE2) and Infinite Reality (IR/IR2) graphics engines. This paper provides an overview of PPIs designed, integrated, tested, and verified at AMCOM MRDEC, specifically the IRSG2's PPI.
Device 2E6 (ACMS) Air Combat Maneuvering Simulator Instructor Console Review.
1983-12-01
While the device provides some new features which support training such as a debrief facility and a computer based instructor training module, the...Equipment Center, Orlando, FL (in printing). - 11 - -~.-. -- ~ --- NAVTRAEQUI PCEN 82-M-0767- 1 PROJECTORS DOE COMPUTER SYSTEMS Figure 1. General...arrangement (2E6) - 12 7 NAVTRAEQUIPCEN 82-M--0767-1 d. instructor stations, e. computer systems, ftarget model subsystem, g. debrief subsystem, h
fVisiOn: glasses-free tabletop 3D display to provide virtual 3D media naturally alongside real media
NASA Astrophysics Data System (ADS)
Yoshida, Shunsuke
2012-06-01
A novel glasses-free tabletop 3D display, named fVisiOn, floats virtual 3D objects on an empty, flat, tabletop surface and enables multiple viewers to observe raised 3D images from any angle at 360° Our glasses-free 3D image reproduction method employs a combination of an optical device and an array of projectors and produces continuous horizontal parallax in the direction of a circular path located above the table. The optical device shapes a hollow cone and works as an anisotropic diffuser. The circularly arranged projectors cast numerous rays into the optical device. Each ray represents a particular ray that passes a corresponding point on a virtual object's surface and orients toward a viewing area around the table. At any viewpoint on the ring-shaped viewing area, both eyes collect fractional images from different projectors, and all the viewers around the table can perceive the scene as 3D from their perspectives because the images include binocular disparity. The entire principle is installed beneath the table, so the tabletop area remains clear. No ordinary tabletop activities are disturbed. Many people can naturally share the 3D images displayed together with real objects on the table. In our latest prototype, we employed a handmade optical device and an array of over 100 tiny projectors. This configuration reproduces static and animated 3D scenes for a 130° viewing area and allows 5-cm-tall virtual characters to play soccer and dance on the table.
Recent progress of 638-nm high-power broad area laser diodes in Mitsubishi Electric
NASA Astrophysics Data System (ADS)
Kuramoto, Kyosuke; Abe, Shinji; Miyashita, Motoharu; Nishida, Takehiro; Yagi, Tetsuya
2018-02-01
Laser based displays have gathered much attention because only the displays can express full color gamut of Ultra-HDTV, ITU-R BT.2020. One of the displays uses the lasers under pulse such as a single spatial light modulator (SLM) projector, and the other does ones under CW such as a multiple SLM projector and a liquid crystal display. Both types require high-power lasers because brightness is the most important factor in the market. We developed two types of 638-nm multi-emitter high-power BA-LDs assembled on Φ9.0-TO, that is, triple emitter for pulse and dual emitter for CW. The triple emitter LD emitted exceeding 6.0 W peak power under 25°C, frequency of 120 Hz, and duty of 30%. At high temperature, 55°C, the peak power was approximately 2.9W. The dual emitter emitted exceeding 3.0W under 25°C, CW. It emitted up to 1.7 W at 55°C. WPE of the dual emitter reached 40.5% at Tc of 25°C, which is the world highest in 638-nm LD under CW to the best of our knowledge, although that of the triple emitter was 38.1%. Both LDs may be suitable for laser based display applications.
Low-cost structured-light based 3D capture system design
NASA Astrophysics Data System (ADS)
Dong, Jing; Bengtson, Kurt R.; Robinson, Barrett F.; Allebach, Jan P.
2014-03-01
Most of the 3D capture products currently in the market are high-end and pricey. They are not targeted for consumers, but rather for research, medical, or industrial usage. Very few aim to provide a solution for home and small business applications. Our goal is to fill in this gap by only using low-cost components to build a 3D capture system that can satisfy the needs of this market segment. In this paper, we present a low-cost 3D capture system based on the structured-light method. The system is built around the HP TopShot LaserJet Pro M275. For our capture device, we use the 8.0 Mpixel camera that is part of the M275. We augment this hardware with two 3M MPro 150 VGA (640 × 480) pocket projectors. We also describe an analytical approach to predicting the achievable resolution of the reconstructed 3D object based on differentials and small signal theory, and an experimental procedure for validating that the system under test meets the specifications for reconstructed object resolution that are predicted by our analytical model. By comparing our experimental measurements from the camera-projector system with the simulation results based on the model for this system, we conclude that our prototype system has been correctly configured and calibrated. We also conclude that with the analytical models, we have an effective means for specifying system parameters to achieve a given target resolution for the reconstructed object.
Color image processing and object tracking workstation
NASA Technical Reports Server (NTRS)
Klimek, Robert B.; Paulick, Michael J.
1992-01-01
A system is described for automatic and semiautomatic tracking of objects on film or video tape which was developed to meet the needs of the microgravity combustion and fluid science experiments at NASA Lewis. The system consists of individual hardware parts working under computer control to achieve a high degree of automation. The most important hardware parts include 16 mm film projector, a lens system, a video camera, an S-VHS tapedeck, a frame grabber, and some storage and output devices. Both the projector and tapedeck have a computer interface enabling remote control. Tracking software was developed to control the overall operation. In the automatic mode, the main tracking program controls the projector or the tapedeck frame incrementation, grabs a frame, processes it, locates the edge of the objects being tracked, and stores the coordinates in a file. This process is performed repeatedly until the last frame is reached. Three representative applications are described. These applications represent typical uses and include tracking the propagation of a flame front, tracking the movement of a liquid-gas interface with extremely poor visibility, and characterizing a diffusion flame according to color and shape.
From the Kochen-Specker theorem to noncontextuality inequalities without assuming determinism.
Kunjwal, Ravi; Spekkens, Robert W
2015-09-11
The Kochen-Specker theorem demonstrates that it is not possible to reproduce the predictions of quantum theory in terms of a hidden variable model where the hidden variables assign a value to every projector deterministically and noncontextually. A noncontextual value assignment to a projector is one that does not depend on which other projectors-the context-are measured together with it. Using a generalization of the notion of noncontextuality that applies to both measurements and preparations, we propose a scheme for deriving inequalities that test whether a given set of experimental statistics is consistent with a noncontextual model. Unlike previous inequalities inspired by the Kochen-Specker theorem, we do not assume that the value assignments are deterministic and therefore in the face of a violation of our inequality, the possibility of salvaging noncontextuality by abandoning determinism is no longer an option. Our approach is operational in the sense that it does not presume quantum theory: a violation of our inequality implies the impossibility of a noncontextual model for any operational theory that can account for the experimental observations, including any successor to quantum theory.
Evaluation of the InFocus TVT-6000 LCTV
NASA Astrophysics Data System (ADS)
Duffey, Jason N.; Jones, Brian K.; Gregory, Don A.; McClain, John L., Jr.
1994-03-01
Liquid crystal televisions have become increasingly popular as low-cost spatial light modulators. While the early devices suffered from poor resolution and low contrast, recent models compare favorably to the more traditional (and expensive) modulators. One of the most recent LCTVs is found in the InFocus TVT-6000 television projector. The panels in this projector have 480 X 440 pixels with a 1.32' diagonal clear aperture. A wavefront splitting interferometer has been constructed and analyzed for measuring the complex characteristics of these modulators, including phase and amplitude coupling. The results of this evaluation will be presented.
Franck, J.V.; Broadhead, P.S.; Skiff, E.W.
1959-07-14
A semiautomatic measuring projector particularly adapted for measurement of the coordinates of photographic images of particle tracks as prcduced in a bubble or cloud chamber is presented. A viewing screen aids the operator in selecting a particle track for measurement. After approximate manual alignment, an image scanning system coupled to a servo control provides automatic exact alignment of a track image with a reference point. The apparatus can follow along a track with a continuous motion while recording coordinate data at various selected points along the track. The coordinate data is recorded on punched cards for subsequent computer calculation of particle trajectory, momentum, etc.
NMR and NQR parameters of ethanol crystal
NASA Astrophysics Data System (ADS)
Milinković, M.; Bilalbegović, G.
2012-04-01
Electric field gradients and chemical shielding tensors of the stable monoclinic crystal phase of ethanol are computed. The projector-augmented wave (PAW) and gauge-including projector-augmented wave (GIPAW) models in the periodic plane-wave density functional theory are used. The crystal data from X-ray measurements, as well as the structures where either all atomic, or only hydrogen atom positions are optimized in the density functional theory are analyzed. These structural models are also studied by including the semi-empirical van der Waals correction to the density functional theory. Infrared spectra of these five crystal models are calculated.
Very-high-resolution time-lapse photography for plant and ecosystems research.
Nichols, Mary H; Steven, Janet C; Sargent, Randy; Dille, Paul; Schapiro, Joshua
2013-09-01
Traditional photography is a compromise between image detail and area covered. We report a new method for creating time-lapse sequences of very-high-resolution photographs to produce zoomable images that facilitate observation across a range of spatial and temporal scales. • A robotic camera mount and software were used to capture images of the growth and movement in Brassica rapa every 15 s in the laboratory. The resultant time-lapse sequence (http://timemachine.gigapan.org/wiki/Plant_Growth) captures growth detail such as circumnutation. A modified, solar-powered system was deployed at a remote field site in southern Arizona. Images were collected every 2 h over a 3-mo period to capture the response of vegetation to monsoon season rainfall (http://timemachine.gigapan.org/wiki/Arizona_Grasslands). • A technique for observing time sequences of both individual plant and ecosystem response at a range of spatial scales is available for use in the laboratory and in the field.
Very-high-resolution time-lapse photography for plant and ecosystems research1
Nichols, Mary H.; Steven, Janet C.; Sargent, Randy; Dille, Paul; Schapiro, Joshua
2013-01-01
• Premise of the study: Traditional photography is a compromise between image detail and area covered. We report a new method for creating time-lapse sequences of very-high-resolution photographs to produce zoomable images that facilitate observation across a range of spatial and temporal scales. • Methods and Results: A robotic camera mount and software were used to capture images of the growth and movement in Brassica rapa every 15 s in the laboratory. The resultant time-lapse sequence (http://timemachine.gigapan.org/wiki/Plant_Growth) captures growth detail such as circumnutation. A modified, solar-powered system was deployed at a remote field site in southern Arizona. Images were collected every 2 h over a 3-mo period to capture the response of vegetation to monsoon season rainfall (http://timemachine.gigapan.org/wiki/Arizona_Grasslands). • Conclusions: A technique for observing time sequences of both individual plant and ecosystem response at a range of spatial scales is available for use in the laboratory and in the field. PMID:25202588
Lifemap: Exploring the Entire Tree of Life.
de Vienne, Damien M
2016-12-01
The Tree of Life (ToL) is meant to be a unique representation of the evolutionary relationships between all species on earth. Huge efforts are made to assemble such a large tree, helped by the decrease of sequencing costs and improved methods to reconstruct and combine phylogenies, but no tool exists today to explore the ToL in its entirety in a satisfying manner. By combining methods used in modern cartography, such as OpenStreetMap, with a new way of representing tree-like structures, I created Lifemap, a tool allowing the exploration of a complete representation of the ToL (between 800,000 and 2.2 million species depending on the data source) in a zoomable interface. A server version of Lifemap also allows users to visualize their own trees. This should help researchers in ecology and evolutionary biology in their everyday work, but may also permit the diffusion to a broader audience of our current knowledge of the evolutionary relationships linking all organisms.
Interval-based reconstruction for uncertainty quantification in PET
NASA Astrophysics Data System (ADS)
Kucharczak, Florentin; Loquin, Kevin; Buvat, Irène; Strauss, Olivier; Mariano-Goulart, Denis
2018-02-01
A new directed interval-based tomographic reconstruction algorithm, called non-additive interval based expectation maximization (NIBEM) is presented. It uses non-additive modeling of the forward operator that provides intervals instead of single-valued projections. The detailed approach is an extension of the maximum likelihood—expectation maximization algorithm based on intervals. The main motivation for this extension is that the resulting intervals have appealing properties for estimating the statistical uncertainty associated with the reconstructed activity values. After reviewing previously published theoretical concepts related to interval-based projectors, this paper describes the NIBEM algorithm and gives examples that highlight the properties and advantages of this interval valued reconstruction.
A Gleason-Type Theorem for Any Dimension Based on a Gambling Formulation of Quantum Mechanics
NASA Astrophysics Data System (ADS)
Benavoli, Alessio; Facchini, Alessandro; Zaffalon, Marco
2017-07-01
Based on a gambling formulation of quantum mechanics, we derive a Gleason-type theorem that holds for any dimension n of a quantum system, and in particular for n=2. The theorem states that the only logically consistent probability assignments are exactly the ones that are definable as the trace of the product of a projector and a density matrix operator. In addition, we detail the reason why dispersion-free probabilities are actually not valid, or rational, probabilities for quantum mechanics, and hence should be excluded from consideration.
Development of an ultra-high temperature infrared scene projector at Santa Barbara Infrared Inc.
NASA Astrophysics Data System (ADS)
Franks, Greg; Laveigne, Joe; Danielson, Tom; McHugh, Steve; Lannon, John; Goodwin, Scott
2015-05-01
The rapid development of very-large format infrared detector arrays has challenged the IR scene projector community to develop correspondingly larger-format infrared emitter arrays to support the testing needs of systems incorporating these detectors. As with most integrated circuits, fabrication yields for the read-in integrated circuit (RIIC) that drives the emitter pixel array are expected to drop dramatically with increasing size, making monolithic RIICs larger than the current 1024x1024 format impractical and unaffordable. Additionally, many scene projector users require much higher simulated temperatures than current technology can generate to fully evaluate the performance of their systems and associated processing algorithms. Under the Ultra High Temperature (UHT) development program, Santa Barbara Infrared Inc. (SBIR) is developing a new infrared scene projector architecture capable of producing both very large format (>1024x1024) resistive emitter arrays and improved emitter pixel technology capable of simulating very high apparent temperatures. During an earlier phase of the program, SBIR demonstrated materials with MWIR apparent temperatures in excess of 1000K. New emitter materials have subsequently been selected to produce pixels that achieve even higher apparent temperatures. Test results from pixels fabricated using the new material set will be presented and discussed. Also in development under the same UHT program is a 'scalable' RIIC that will be used to drive the high temperature pixels. This RIIC will utilize through-silicon vias (TSVs) and quilt packaging (QP) technologies to allow seamless tiling of multiple chips to fabricate very large arrays, and thus overcome the inherent yield limitations of very-large-scale integrated circuits. Current status of the RIIC development effort will also be presented.
Aerial 3D display by use of a 3D-shaped screen with aerial imaging by retro-reflection (AIRR)
NASA Astrophysics Data System (ADS)
Kurokawa, Nao; Ito, Shusei; Yamamoto, Hirotsugu
2017-06-01
The purpose of this paper is to realize an aerial 3D display. We design optical system that employs a projector below a retro-reflector and a 3D-shaped screen. A floating 3D image is formed with aerial imaging by retro-reflection (AIRR). Our proposed system is composed of a 3D-shaped screen, a projector, a quarter-wave retarder, a retro-reflector, and a reflective polarizer. Because AIRR forms aerial images that are plane-symmetric of the light sources regarding the reflective polarizer, the shape of the 3D screen is inverted from a desired aerial 3D image. In order to expand viewing angle, the 3D-shaped screen is surrounded by a retro-reflector. In order to separate the aerial image from reflected lights on the retro- reflector surface, the retro-reflector is tilted by 30 degrees. A projector is located below the retro-reflector at the same height of the 3D-shaped screen. The optical axis of the projector is orthogonal to the 3D-shaped screen. Scattered light on the 3D-shaped screen forms the aerial 3D image. In order to demonstrate the proposed optical design, a corner-cube-shaped screen is used for the 3D-shaped screen. Thus, the aerial 3D image is a cube that is floating above the reflective polarizer. For example, an aerial green cube is formed by projecting a calculated image on the 3D-shaped screen. The green cube image is digitally inverted in depth by our developed software. Thus, we have succeeded in forming aerial 3D image with our designed optical system.
High-temperature MIRAGE XL (LFRA) IRSP system development
NASA Astrophysics Data System (ADS)
McHugh, Steve; Franks, Greg; LaVeigne, Joe
2017-05-01
The development of very-large format infrared detector arrays has challenged the IR scene projector community to develop larger-format infrared emitter arrays. Many scene projector applications also require much higher simulated temperatures than can be generated with current technology. This paper will present an overview of resistive emitterbased (broadband) IR scene projector system development, as well as describe recent progress in emitter materials and pixel designs applicable for legacy MIRAGE XL Systems to achieve apparent temperatures >1000K in the MWIR. These new high temperature MIRAGE XL (LFRA) Digital Emitter Engines (DEE) will be "plug and play" equivalent with legacy MIRAGE XL DEEs, the rest of the system is reusable. Under the High Temperature Dynamic Resistive Array (HDRA) development program, Santa Barbara Infrared Inc. (SBIR) is developing a new infrared scene projector architecture capable of producing both very large format (>2k x 2k) resistive emitter arrays and improved emitter pixel technology capable of simulating very high apparent temperatures. During earlier phases of the program, SBIR demonstrated materials with MWIR apparent temperatures in excess of 1500 K. These new emitter materials can be utilized with legacy RIICs to produce pixels that can achieve 7X the radiance of the legacy systems with low cost and low risk. A 'scalable' Read-In Integrated Circuit (RIIC) is also being developed under the same HDRA program to drive the high temperature pixels. This RIIC will utilize through-silicon via (TSV) and Quilt Packaging (QP) technologies to allow seamless tiling of multiple chips to fabricate very large arrays, and thus overcome the yield limitations inherent in large-scale integrated circuits. These quilted arrays can be fabricated in any N x M size in 512 steps.
Dohn, A O; Jónsson, E Ö; Levi, G; Mortensen, J J; Lopez-Acevedo, O; Thygesen, K S; Jacobsen, K W; Ulstrup, J; Henriksen, N E; Møller, K B; Jónsson, H
2017-12-12
A multiscale density functional theory-quantum mechanics/molecular mechanics (DFT-QM/MM) scheme is presented, based on an efficient electrostatic coupling between the electronic density obtained from a grid-based projector augmented wave (GPAW) implementation of density functional theory and a classical potential energy function. The scheme is implemented in a general fashion and can be used with various choices for the descriptions of the QM or MM regions. Tests on H 2 O clusters, ranging from dimer to decamer show that no systematic energy errors are introduced by the coupling that exceeds the differences in the QM and MM descriptions. Over 1 ns of liquid water, Born-Oppenheimer QM/MM molecular dynamics (MD) are sampled combining 10 parallel simulations, showing consistent liquid water structure over the QM/MM border. The method is applied in extensive parallel MD simulations of an aqueous solution of the diplatinum [Pt 2 (P 2 O 5 H 2 ) 4 ] 4- complex (PtPOP), spanning a total time period of roughly half a nanosecond. An average Pt-Pt distance deviating only 0.01 Å from experimental results, and a ground-state Pt-Pt oscillation frequency deviating by <2% from experimental results were obtained. The simulations highlight a remarkable harmonicity of the Pt-Pt oscillation, while also showing clear signs of Pt-H hydrogen bonding and directional coordination of water molecules along the Pt-Pt axis of the complex.
NASA Astrophysics Data System (ADS)
Mao, Cuili; Lu, Rongsheng; Liu, Zhijian
2018-07-01
In fringe projection profilometry, the phase errors caused by the nonlinear intensity response of digital projectors needs to be correctly compensated. In this paper, a multi-frequency inverse-phase method is proposed. The theoretical model of periodical phase errors is analyzed. The periodical phase errors can be adaptively compensated in the wrapped maps by using a set of fringe patterns. The compensated phase is then unwrapped with multi-frequency method. Compared with conventional methods, the proposed method can greatly reduce the periodical phase error without calibrating measurement system. Some simulation and experimental results are presented to demonstrate the validity of the proposed approach.
NASA Technical Reports Server (NTRS)
Chase, W. D.
1975-01-01
The calligraphic chromatic projector described was developed to improve the perceived realism of visual scene simulation ('out-the-window visuals'). The optical arrangement of the projector is illustrated and discussed. The device permits drawing 2000 vectors in as many as 500 colors, all above critical flicker frequencies, and use of high scene resolution and brightness at an acceptable level to the pilot, with the maximum system capabilities of 1000 lines and 1000 fL. The device for generating the colors is discussed, along with an experiment conducted to demonstrate potential improvements in performance and pilot opinion. Current research work and future research plans are noted.
NASA Astrophysics Data System (ADS)
Alfianto, E.; Rusydi, F.; Aisyah, N. D.; Fadilla, R. N.; Dipojono, H. K.; Martoprawiro, M. A.
2017-05-01
This study implemented DFT method into the C++ programming language with object-oriented programming rules (expressive software). The use of expressive software results in getting a simple programming structure, which is similar to mathematical formula. This will facilitate the scientific community to develop the software. We validate our software by calculating the energy band structure of Silica, Carbon, and Germanium with FCC structure using the Projector Augmented Wave (PAW) method then compare the results to Quantum Espresso calculation’s results. This study shows that the accuracy of the software is 85% compared to Quantum Espresso.
Laser scatter feature of surface defect on apples
NASA Astrophysics Data System (ADS)
Rao, Xiuqin; Ying, Yibin; Cen, YiKe; Huang, Haibo
2006-10-01
A machine vision system for real-time fruit quality inspection was developed. The system consists of a chamber, a laser projector, a TMS-7DSP CCD camera (PULNIX Inc.), and a computer. A Meteor-II/MC frame grabber (Matrox Graphics Inc.) was inserted into the slot of the computer to grab fruit images. The laser projector and the camera were mounted at the ceiling of the chamber. An apple was put in the chamber, the spot of the laser projector was projected on the surface of the fruit, and an image was grabbed. 2 breed of apples was test, Each apple was imaged twice, one was imaged for the normal surface, and the other for the defect. The red component of the images was used to get the feature of the defect and the sound surface of the fruits. The average value, STD value and comentropy Value of red component of the laser scatter image were analyzed. The Standard Deviation value of red component of normal is more suitable to separate the defect surface from sound surface for the ShuijinFuji apples, but for bintang apples, there is more work need to do to separate the different surface with laser scatter image.
Topographic instructions, Book 3, multiplex procedure; Chapter 3 C7a-e
Loud, Edward I.
1952-01-01
By direct projection of overlapping photographs, printed on glass plates, the multiplex produces an exact optical model, in miniature, of the terrain to be mapped. To create the model, the multiplex projectors must be properly positioned and oriented so that they duplicate the orientation of the aerial camera at the instant of each exposure. By means of a floating mark, horizontal and vertical measurements can be made in the model, and planimetry and contours can be drawn. The applicability of the multiplex to a given mapping project depends largely on the contour interval and compilation scale required, and also depends, to a lesser extent, on the vegetation and terrain cover as it may affect accuracy requirements. The steps in multiplex procedure are orientation, stereotriangulation, and compilation of detail. In orientation, the projectors are arranged so that the projected images form a stereoscopic model which can be adjusted to fit horizontal and vertical control points. In stereotriangulation, three or more multiplex projectors are oriented so that the consecutive models fit existing control, permitting the establishment of additional or intermediate control. In compilation, the features appearing in the model are delineated on the map manuscript.
Nomad devices for interactions in immersive virtual environments
NASA Astrophysics Data System (ADS)
George, Paul; Kemeny, Andras; Merienne, Frédéric; Chardonnet, Jean-Rémy; Thouvenin, Indira Mouttapa; Posselt, Javier; Icart, Emmanuel
2013-03-01
Renault is currently setting up a new CAVE™, a 5 rear-projected wall virtual reality room with a combined 3D resolution of 100 Mpixels, distributed over sixteen 4k projectors and two 2k projector as well as an additional 3D HD collaborative powerwall. Renault's CAVE™ aims at answering needs of the various vehicle conception steps [1]. Starting from vehicle Design, through the subsequent Engineering steps, Ergonomic evaluation and perceived quality control, Renault has built up a list of use-cases and carried out an early software evaluation in the four sided CAVE™ of Institute Image, called MOVE. One goal of the project is to study interactions in a CAVE™, especially with nomad devices such as IPhone or IPad to manipulate virtual objects and to develop visualization possibilities. Inspired by nomad devices current uses (multi-touch gestures, IPhone UI look'n'feel and AR applications), we have implemented an early feature set taking advantage of these popular input devices. In this paper, we present its performance through measurement data collected in our test platform, a 4-sided homemade low-cost virtual reality room, powered by ultra-short-range and standard HD home projectors.
A modular projection autostereoscopic system for stereo cinema
NASA Astrophysics Data System (ADS)
Elkhov, Victor A.; Kondratiev, Nikolai V.; Ovechkis, Yuri N.; Pautova, Larisa V.
2009-02-01
The lenticular raster system for 3D movies non-glasses show designed by NIKFI demonstrated commercially in Moscow in the 40'st of the last century. Essential lack of this method was narrow individual viewing zone as only two images on the film used. To solve this problem, we propose to use digital video projective system with modular principle of its design. Increase of the general number of the pixels forming the stereo image is reached by using of more than one projector. The modular projection autostereoscopic system for demonstration of the 3D movies includes diffuser screen; lenticular plate located in front of the screen; projective system consisted from several projectors and the block of parallax panoramogram fragments creator. By means of this block the parallax panoramogram is broken into fragments which quantity corresponds to number of projectors. For the large dimension lenticular screen making rectangular fragments of inclined raster were joined in a uniform leaf. To obtain the needed focal distance of the screen lenses we used immersion - aqueous solution of glycerin. The immersion also let essentially decrease visibility of fragments joints. An experimental prototype of the modular projection autostereoscopic system was created to validate proposed system.
Visualization in aerospace research with a large wall display system
NASA Astrophysics Data System (ADS)
Matsuo, Yuichi
2002-05-01
National Aerospace Laboratory of Japan has built a large- scale visualization system with a large wall-type display. The system has been operational since April 2001 and comprises a 4.6x1.5-meter (15x5-foot) rear projection screen with 3 BARCO 812 high-resolution CRT projectors. The reason we adopted the 3-gun CRT projectors is support for stereoscopic viewing, ease with color/luminosity matching and accuracy of edge-blending. The system is driven by a new SGI Onyx 3400 server of distributed shared-memory architecture with 32 CPUs, 64Gbytes memory, 1.5TBytes FC RAID disk and 6 IR3 graphics pipelines. Software is another important issue for us to make full use of the system. We have introduced some applications available in a multi- projector environment such as AVS/MPE, EnSight Gold and COVISE, and been developing some software tools that create volumetric images with using SGI graphics libraries. The system is mainly used for visualization fo computational fluid dynamics (CFD) simulation sin aerospace research. Visualized CFD results are of our help for designing an improved configuration of aerospace vehicles and analyzing their aerodynamic performances. These days we also use it for various collaborations among researchers.
Control of Coastal Lighting in Anti-Submarine Warfare
1943-04-30
diameter 18 15 Cardboard used to shield lighting units at Jacksonville Beach,, Florida 19 16 Power :leads, wiring harness, and headlamp switch 19 17...1000 feet from searchlight used’"’ to insure measurements in same portion S of beam 26 28 Power supply for beach searchlight 27 29 Ceiling projector...as availability of eleccric power , existence ofVteleph ne lines, proximity to bases for the seacraft and air-craft required, nuarters for the troops, f
High-speed three-dimensional shape measurement using GOBO projection
NASA Astrophysics Data System (ADS)
Heist, Stefan; Lutzke, Peter; Schmidt, Ingo; Dietrich, Patrick; Kühmstedt, Peter; Tünnermann, Andreas; Notni, Gunther
2016-12-01
A projector which uses a rotating slide structure to project aperiodic sinusoidal fringe patterns at high frame rates and with high radiant flux is introduced. It is used in an optical three-dimensional (3D) sensor based on coded-light projection, thus allowing the analysis of fast processes. Measurements of an inflating airbag, a rope skipper, and a soccer ball kick at a 3D frame rate of more than 1300 independent point clouds per second are presented.
PhishGuru: A System for Educating Users about Semantic Attacks
2009-04-14
Psychological based social engineering. Tech. rep., SANS Institute, 2003. [119] Macmillan, N. A., and Creelman , C. D. Detection Theory: A User’s Guide...36, 76, 84, 148, 157, 161]. In marketing, the focus is on strategies to enhance consumer persuasion and trust building [37,40,68, 189]. In psychology ...and science, social work, fine arts, nursing, music, and psychology . Two of the participants had only a high school degree. Using a wall projector, we
High-Resolution Surface Reconstruction from Imagery for Close Range Cultural Heritage Applications
NASA Astrophysics Data System (ADS)
Wenzel, K.; Abdel-Wahab, M.; Cefalu, A.; Fritsch, D.
2012-07-01
The recording of high resolution point clouds with sub-mm resolution is a demanding and cost intensive task, especially with current equipment like handheld laser scanners. We present an image based approached, where techniques of image matching and dense surface reconstruction are combined with a compact and affordable rig of off-the-shelf industry cameras. Such cameras provide high spatial resolution with low radiometric noise, which enables a one-shot solution and thus an efficient data acquisition while satisfying high accuracy requirements. However, the largest drawback of image based solutions is often the acquisition of surfaces with low texture where the image matching process might fail. Thus, an additional structured light projector is employed, represented here by the pseudo-random pattern projector of the Microsoft Kinect. Its strong infrared-laser projects speckles of different sizes. By using dense image matching techniques on the acquired images, a 3D point can be derived for almost each pixel. The use of multiple cameras enables the acquisition of a high resolution point cloud with high accuracy for each shot. For the proposed system up to 3.5 Mio. 3D points with sub-mm accuracy can be derived per shot. The registration of multiple shots is performed by Structure and Motion reconstruction techniques, where feature points are used to derive the camera positions and rotations automatically without initial information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hégely, Bence; Nagy, Péter R.; Kállay, Mihály, E-mail: kallay@mail.bme.hu
Exact schemes for the embedding of density functional theory (DFT) and wave function theory (WFT) methods into lower-level DFT or WFT approaches are introduced utilizing orbital localization. First, a simple modification of the projector-based embedding scheme of Manby and co-workers [J. Chem. Phys. 140, 18A507 (2014)] is proposed. We also use localized orbitals to partition the system, but instead of augmenting the Fock operator with a somewhat arbitrary level-shift projector we solve the Huzinaga-equation, which strictly enforces the Pauli exclusion principle. Second, the embedding of WFT methods in local correlation approaches is studied. Since the latter methods split up themore » system into local domains, very simple embedding theories can be defined if the domains of the active subsystem and the environment are treated at a different level. The considered embedding schemes are benchmarked for reaction energies and compared to quantum mechanics (QM)/molecular mechanics (MM) and vacuum embedding. We conclude that for DFT-in-DFT embedding, the Huzinaga-equation-based scheme is more efficient than the other approaches, but QM/MM or even simple vacuum embedding is still competitive in particular cases. Concerning the embedding of wave function methods, the clear winner is the embedding of WFT into low-level local correlation approaches, and WFT-in-DFT embedding can only be more advantageous if a non-hybrid density functional is employed.« less
Cheng, Victor S; Bai, Jinfen; Chen, Yazhu
2009-11-01
As the needs for various kinds of body surface information are wide-ranging, we developed an imaging-sensor integrated system that can synchronously acquire high-resolution three-dimensional (3D) far-infrared (FIR) thermal and true-color images of the body surface. The proposed system integrates one FIR camera and one color camera with a 3D structured light binocular profilometer. To eliminate the emotion disturbance of the inspector caused by the intensive light projection directly into the eye from the LCD projector, we have developed a gray encoding strategy based on the optimum fringe projection layout. A self-heated checkerboard has been employed to perform the calibration of different types of cameras. Then, we have calibrated the structured light emitted by the LCD projector, which is based on the stereo-vision idea and the least-squares quadric surface-fitting algorithm. Afterwards, the precise 3D surface can fuse with undistorted thermal and color images. To enhance medical applications, the region-of-interest (ROI) in the temperature or color image representing the surface area of clinical interest can be located in the corresponding position in the other images through coordinate system transformation. System evaluation demonstrated a mapping error between FIR and visual images of three pixels or less. Experiments show that this work is significantly useful in certain disease diagnoses.
Front and rear projection autostereoscopic 3D displays based on lenticular sheets
NASA Astrophysics Data System (ADS)
Wang, Qiong-Hua; Zang, Shang-Fei; Qi, Lin
2015-03-01
A front projection autostereoscopic display is proposed. The display is composed of eight projectors and a 3D-imageguided screen which having a lenticular sheet and a retro-reflective diffusion screen. Based on the optical multiplexing and de-multiplexing, the optical functions of the 3D-image-guided screen are parallax image interlacing and viewseparating, which is capable of reconstructing 3D images without quality degradation from the front direction. The operating principle, optical design calculation equations and correction method of parallax images are given. A prototype of the front projection autostereoscopic display is developed, which enhances the brightness and 3D perceptions, and improves space efficiency. The performance of this prototype is evaluated by measuring the luminance and crosstalk distribution along the horizontal direction at the optimum viewing distance. We also propose a rear projection autostereoscopic display. The display consists of eight projectors, a projection screen, and two lenticular sheets. The operation principle and calculation equations are described in detail and the parallax images are corrected by means of homography. A prototype of the rear projection autostereoscopic display is developed. The normalized luminance distributions of viewing zones from the measurement are given. Results agree well with the designed values. The prototype presents high resolution and high brightness 3D images. The research has potential applications in some commercial entertainments and movies for the realistic 3D perceptions.
New ultraportable display technology and applications
NASA Astrophysics Data System (ADS)
Alvelda, Phillip; Lewis, Nancy D.
1998-08-01
MicroDisplay devices are based on a combination of technologies rooted in the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates. Customized diffraction grating and optical distortion correction technology for lens-system compensation allow the elimination of many lenses and systems-level components. The MicroDisplay Corporation's miniature integrated information display technology is rapidly leading to many new defense and commercial applications. There are no moving parts in MicroDisplay substrates, and the fabrication of the color generating gratings, already part of the CMOS circuit fabrication process, is effectively cost and manufacturing process-free. The entire suite of the MicroDisplay Corporation's technologies was devised to create a line of application- specific integrated circuit single-chip display systems with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass and head mounted displays, pagers and Personal Communication Services hand-sets, and wristwatch-mounted video phones are among the may target commercial markets for MicroDisplay technology. Defense applications range from Maintenance and Repair support, to night-vision systems, to portable projectors for mobile command and control centers.
NASA Astrophysics Data System (ADS)
Culpitt, Tanner; Brorsen, Kurt R.; Hammes-Schiffer, Sharon
2017-06-01
Density functional theory (DFT) embedding approaches have generated considerable interest in the field of computational chemistry because they enable calculations on larger systems by treating subsystems at different levels of theory. To circumvent the calculation of the non-additive kinetic potential, various projector methods have been developed to ensure the orthogonality of molecular orbitals between subsystems. Herein the orthogonality constrained basis set expansion (OCBSE) procedure is implemented to enforce this subsystem orbital orthogonality without requiring a level shifting parameter. This scheme is a simple alternative to existing parameter-free projector-based schemes, such as the Huzinaga equation. The main advantage of the OCBSE procedure is that excellent convergence behavior is attained for DFT-in-DFT embedding without freezing any of the subsystem densities. For the three chemical systems studied, the level of accuracy is comparable to or higher than that obtained with the Huzinaga scheme with frozen subsystem densities. Allowing both the high-level and low-level DFT densities to respond to each other during DFT-in-DFT embedding calculations provides more flexibility and renders this approach more generally applicable to chemical systems. It could also be useful for future extensions to embedding approaches combining wavefunction theories and DFT.
A High Spatial Resolution Depth Sensing Method Based on Binocular Structured Light
Yao, Huimin; Ge, Chenyang; Xue, Jianru; Zheng, Nanning
2017-01-01
Depth information has been used in many fields because of its low cost and easy availability, since the Microsoft Kinect was released. However, the Kinect and Kinect-like RGB-D sensors show limited performance in certain applications and place high demands on accuracy and robustness of depth information. In this paper, we propose a depth sensing system that contains a laser projector similar to that used in the Kinect, and two infrared cameras located on both sides of the laser projector, to obtain higher spatial resolution depth information. We apply the block-matching algorithm to estimate the disparity. To improve the spatial resolution, we reduce the size of matching blocks, but smaller matching blocks generate lower matching precision. To address this problem, we combine two matching modes (binocular mode and monocular mode) in the disparity estimation process. Experimental results show that our method can obtain higher spatial resolution depth without loss of the quality of the range image, compared with the Kinect. Furthermore, our algorithm is implemented on a low-cost hardware platform, and the system can support the resolution of 1280 × 960, and up to a speed of 60 frames per second, for depth image sequences. PMID:28397759
Ab Initio Theory of Nuclear Magnetic Resonance Shifts in Metals
NASA Astrophysics Data System (ADS)
D'Avezac, Mayeul; Marzari, Nicola; Mauri, Francesco
2005-03-01
A comprehensive approach for the first-principles determination of all-electron NMR shifts in metallic systems is presented. Our formulation is based on a combination of density-functional perturbation theory and all-electron wavefunction reconstruction, starting from periodic-boundary calculations in the pseudopotential approximation. The orbital contribution to the NMR shift (the chemical shift) is obtained by combining the gauge-including projector augmented-wave approach (GIPAW), originally developed for the case of insulatorsootnotetextC. J. Pickard, Francesco Mauri, Phys. Rev. B, 63, 245101(2001), with the extension of linear-response theory to the case of metallic systemsootnotetextS. de Gironcoli, Phys. Rev. B, 51, 6773(1995). The spin contribution (the Knight shift) is obtained as a response to a finite uniform magnetic field, and through reconstructing the hyperfine interaction between the electron-spin density and the nuclear spins with the projector augmented-wave method (PAWootnotetextC. G. Van de Walle, P. E. Blöchl, Phys. Rev. B, 47, 4244(1993)). Our method is validated with applications to the case of the homogeneous electron gas and of simple metals. (Work supported by MURI grant DAAD 19-03-1-0169 and MIT-France)
Optical system for object detection and delineation in space
NASA Astrophysics Data System (ADS)
Handelman, Amir; Shwartz, Shoam; Donitza, Liad; Chaplanov, Loran
2018-01-01
Object recognition and delineation is an important task in many environments, such as in crime scenes and operating rooms. Marking evidence or surgical tools and attracting the attention of the surrounding staff to the marked objects can affect people's lives. We present an optical system comprising a camera, computer, and small laser projector that can detect and delineate objects in the environment. To prove the optical system's concept, we show that it can operate in a hypothetical crime scene in which a pistol is present and automatically recognize and segment it by various computer-vision algorithms. Based on such segmentation, the laser projector illuminates the actual boundaries of the pistol and thus allows the persons in the scene to comfortably locate and measure the pistol without holding any intermediator device, such as an augmented reality handheld device, glasses, or screens. Using additional optical devices, such as diffraction grating and a cylinder lens, the pistol size can be estimated. The exact location of the pistol in space remains static, even after its removal. Our optical system can be fixed or dynamically moved, making it suitable for various applications that require marking of objects in space.
NASA Astrophysics Data System (ADS)
Li, Wanjing; Schütze, Rainer; Böhler, Martin; Boochs, Frank; Marzani, Franck S.; Voisin, Yvon
2009-06-01
We present an approach to integrate a preprocessing step of the region of interest (ROI) localization into 3-D scanners (laser or stereoscopic). The definite objective is to make the 3-D scanner intelligent enough to localize rapidly in the scene, during the preprocessing phase, the regions with high surface curvature, so that precise scanning will be done only in these regions instead of in the whole scene. In this way, the scanning time can be largely reduced, and the results contain only pertinent data. To test its feasibility and efficiency, we simulated the preprocessing process under an active stereoscopic system composed of two cameras and a video projector. The ROI localization is done in an iterative way. First, the video projector projects a regular point pattern in the scene, and then the pattern is modified iteratively according to the local surface curvature of each reconstructed 3-D point. Finally, the last pattern is used to determine the ROI. Our experiments showed that with this approach, the system is capable to localize all types of objects, including small objects with small depth.
Did Caravaggio employ optical projections? An image analysis of the parity in the artist's paintings
NASA Astrophysics Data System (ADS)
Stork, David G.
2011-03-01
We examine one class of evidence put forth in support of the recent claim that the Italian Baroque master Caravaggio secretly employed optical projectors as a direct drawing aid. Specically, we test the claims that there is an "abnormal number" of left-handed gures in his works and, more specically, that "During the Del Monte period he had too many left-handed models." We also test whether there was a reversal in the handedness of specic models in different paintings. Such evidence would be consistent with the claim that Caravaggio switched between using a convex-lens projector to using a concave-mirror projector and would support, but not prove, the claim that Caravaggio used optical projections. We estimate the parity (+ or -) of each of Caravaggio's 76 appropriate oil paintings based on the handedness of gures, the orientation of asymmetric objects, placement of scabbards, depicted text, and so on, and search for statistically significant changes in handedness in figures. We also track the direction of the illumination over time in the artist's uvre. We discuss some historical evidence as it relates to the question of his possible use of optics. We nd the proportion of left-handed figures lower than that in the general population (not higher), and no significant change in estimated handedness even of individual models. Optical proponents have argued that Bacchus (1597) portrays a left-handed gure, but we give visual and cultural evidence showing that this gure is instead right-handed, thereby rebutting this claim that the painting was executed using optical projections. Moreover, scholars recently re-discovered the image of the artist with easel and canvas reflected in the carafe of wine at the front left in the tableau in Bacchus, showing that this painting was almost surely executed using traditional (non-optical) easel methods. We conclude that there is 1) no statistically signicant abnormally high number of left-handed gures in Caravaggio's uvre, including during any limited working period, 2) no statistically significant change in handedness among all gures or even individual gures that might be consistent with a change in optical projector, and 3) the visual and cultural evidence in Bacchus shows the gure was right-handed and that the artist executed this work by traditional (non-optical) easel methods. We conclude that the general parity and handedness evidence does not support the claim that Caravaggio employed optical projections.
PTWC Creating a New Catalog of Historic Tsunami Animations for NOAA Science-on-a-Sphere Exhibits
NASA Astrophysics Data System (ADS)
Becker, N. C.; Geschwind, L. R.; Wang, D.
2016-12-01
Throughout 2016 the Pacific Tsunami Warning Center (PTWC) has been developing a catalog of tsunami animations for NOAA's Science on a Sphere (SOS) display system. The SOS consists of a six-foot (1.8 m) diameter sphere that serves as a projection screen for four high-definition video projectors that can show any global dataset. SOS systems have been installed in over 100 locations around the world, primarily in venues such as science museums. Education and outreach are a vital part of PTWC's mission and SOS can show the global impacts of tsunami hazards in an intuitive and engaging presentation analogous to a planetarium. PTWC has been releasing these animations for the anniversaries of significant tsunamis throughout the year and has so far has produced them for Cascadia 1700, Chile 2010, Japan 2011, Aleutian Islands 1946, Alaska 1964, and Chile 1960, and before the end of the year the library will include Samoa 2009 and Sumatra 2004. PTWC created these animations at 8k video resolution to future-proof them against SOS upgrades such as higher definition projectors and larger spheres. Though not the first SOS tsunami animations, these are the first ones to show impacts to coastlines, the criteria that PTWC uses to determine the tsunami hazard guidance it will issue to the coastal populations it serves. These animations also all use a common color scheme based on PTWC's alert criteria such that they will be consistent with each other as well as with PTWC's tsunami messages. PTWC created these animations using the same tsunami forecast model it routinely uses in its warning operations, and PTWC has even demonstrated that it can produce a SOS tsunami animation while a tsunami was still crossing the Pacific Ocean, and so this library of animations can also be used to prepare docents and audiences to interpret such a real-time animation should it become available for the next major tsunami. One does not need access to a SOS exhibit, however, to view these animations. NOAA also maintains a website where these animations can be viewed in a web browser. The site also allows a user to download these data along with software such that they may be viewed on a personal computer. PTWC also maintains a YouTube channel with Mercator-projected versions of these animations that are in the same style and color scheme as their SOS counterparts.
A hyperspectral image projector for hyperspectral imagers
NASA Astrophysics Data System (ADS)
Rice, Joseph P.; Brown, Steven W.; Neira, Jorge E.; Bousquet, Robert R.
2007-04-01
We have developed and demonstrated a Hyperspectral Image Projector (HIP) intended for system-level validation testing of hyperspectral imagers, including the instrument and any associated spectral unmixing algorithms. HIP, based on the same digital micromirror arrays used in commercial digital light processing (DLP*) displays, is capable of projecting any combination of many different arbitrarily programmable basis spectra into each image pixel at up to video frame rates. We use a scheme whereby one micromirror array is used to produce light having the spectra of endmembers (i.e. vegetation, water, minerals, etc.), and a second micromirror array, optically in series with the first, projects any combination of these arbitrarily-programmable spectra into the pixels of a 1024 x 768 element spatial image, thereby producing temporally-integrated images having spectrally mixed pixels. HIP goes beyond conventional DLP projectors in that each spatial pixel can have an arbitrary spectrum, not just arbitrary color. As such, the resulting spectral and spatial content of the projected image can simulate realistic scenes that a hyperspectral imager will measure during its use. Also, the spectral radiance of the projected scenes can be measured with a calibrated spectroradiometer, such that the spectral radiance projected into each pixel of the hyperspectral imager can be accurately known. Use of such projected scenes in a controlled laboratory setting would alleviate expensive field testing of instruments, allow better separation of environmental effects from instrument effects, and enable system-level performance testing and validation of hyperspectral imagers as used with analysis algorithms. For example, known mixtures of relevant endmember spectra could be projected into arbitrary spatial pixels in a hyperspectral imager, enabling tests of how well a full system, consisting of the instrument + calibration + analysis algorithm, performs in unmixing (i.e. de-convolving) the spectra in all pixels. We discuss here the performance of a visible prototype HIP. The technology is readily extendable to the ultraviolet and infrared spectral ranges, and the scenes can be static or dynamic.
Coloured computational imaging with single-pixel detectors based on a 2D discrete cosine transform
NASA Astrophysics Data System (ADS)
Liu, Bao-Lei; Yang, Zhao-Hua; Liu, Xia; Wu, Ling-An
2017-02-01
We propose and demonstrate a computational imaging technique that uses structured illumination based on a two-dimensional discrete cosine transform to perform imaging with a single-pixel detector. A scene is illuminated by a projector with two sets of orthogonal patterns, then by applying an inverse cosine transform to the spectra obtained from the single-pixel detector a full-colour image is retrieved. This technique can retrieve an image from sub-Nyquist measurements, and the background noise is easily cancelled to give excellent image quality. Moreover, the experimental set-up is very simple.
Yoshida, Shunsuke
2016-06-13
A novel glasses-free tabletop 3D display to float virtual objects on a flat tabletop surface is proposed. This method employs circularly arranged projectors and a conical rear-projection screen that serves as an anisotropic diffuser. Its practical implementation installs them beneath a round table and produces horizontal parallax in a circumferential direction without the use of high speed or a moving apparatus. Our prototype can display full-color, 5-cm-tall 3D characters on the table. Multiple viewers can share and enjoy its real-time animation from any angle of 360 degrees with appropriate perspectives as if the animated figures were present.
Merkulova, A G; Osokina, E S; Bukhtiiarov, I V
2014-10-01
The case of compare two ways of projection color visual images, characterized by different spatial-temporal characteristics of visual stimuli, presents the methodology and the set of techniques. Received comparative data, identifying risks of regulation disorder of the functional state and development general, mental and visual fatigue during prolonged strenuous visual activity, according to two types of test tasks, which are the most typical for the use of modern projectors to work with the audience, both inthe process of implementation of learning technologies and the collective take responsible decisions by expert groups that control of complex technological processes.
Using OWL in a Pervasive Computing Broker
2005-01-01
carries or wears (e.g., cell phones , PDAs and headphones), services that are provided by de- vices in a room (e.g., projector service, light controller...ence of the users’ devices and clothing. As Alice enters the room, these sensors inform the R210 broker that a cell phone belonging to her is present and...the broker adds this fact in its knowledge base. As she sits, the agent on Alice’s Bluetooth enabled cell phone discovers R210’s broker and engages
A Pyramid Scheme for Constructing Geologic Maps on Geobrowsers
NASA Astrophysics Data System (ADS)
Whitmeyer, S. J.; de Paor, D. G.; Daniels, J.; Jeremy, N.; Michael, R.; Santangelo, B.
2008-12-01
Hundreds of geologic maps have been draped onto Google Earth (GE) using the ground overlay tag of Keyhole Markup Language (KML) and dozens have been published on academic and survey web pages as downloadable KML or KMZ (zipped KML) files. The vast majority of these are small KML docs that link to single, large - often very large - image files (jpegs, tiffs, etc.) Files that exceed 50 MB in size defeat the purpose of GE as an interactive and responsive, and therefore fast, virtual terrain medium. KML supports super-overlays (a.k.a. image pyramids), which break large graphic files into manageable tiles that load only when they are in the visible region at a sufficient level of detail (LOD), and several automatic tile-generating applications have been written. The process of exporting map data from applications such as ArcGIS® to KML format is becoming more manageable but still poses challenges. Complications arise, for example, because of differences between grid-north at a point on a map and true north at the equivalent location on the virtual globe. In our recent field season, we devised ways of overcoming many of these obstacles in order to generate responsive, panable, zoomable geologic maps in which data is layered in a pyramid structure similar to the image pyramid used for default GE terrain. The structure of our KML code for each level of the pyramid is self-similar: (i) check whether the current tile is in the visible region, (ii) if so, render the current overlay, (iii) add the current data level, and (iv) using four network links, check the visibility and LOD of four nested tiles. By using this pyramid structure we provide the user with access to geologic and map data at multiple levels of observation. For example, when the viewpoint is distant, regional structures and stratigraphy (e.g. lithological groups and terrane boundaries) are visible. As the user zooms to lower elevations, formations and ultimately individual outcrops come into focus. The pyramid structure is ideally suited to geologic data which tends to be unevenly exposed across the earth's surface.
World's Most Advanced Planetarium Opens; University Partners Sought
NASA Astrophysics Data System (ADS)
Duncan, Douglas K.
2015-01-01
The 40 year old-Fiske Planetarium at the Univ. of Colorado has remodeled as the most advanced planetarium ever built. The 20m diameter dome features a stunning video image 8,000 x 8,000 pixels, up to 60 frames per second, produced by 6 JVC projectors. It also features the first US installation of the Megastar IIa Opto-mechanical planetarium that projects 20 million individual stars and 170 deep sky objects. You can use binoculars indoor and see individual Milky Way stars.The video projectors have high dynamic range, but not as great as the eye. In order to preserve the remarkable Megastar sky while still using video, each projector shines through a computer controlled variable density filter than extends the dynamic range by about 4 magnitudes. It therefore is possible to show a Mauna Kea quality star field and also beautiful bright videos.Unlike most planetariums, the #1 audience of Fiske is college students - the more than 2,000 who take Introductory Astronomy at Colorado each year. WE ARE SEEKING OTHER UNIVERSITIES WITH FULL-DOME VIDEO PLANETARIUMS to join us in the production of college-level material. We already have a beautiful production studio funded by Hewlett Packard and an experienced full-time Video Producer for Educational Programs. Please seek out Fiske Director Dr. Doug Duncan if interested in possible collaboration.
Comparative analysis of local spin definitions.
Herrmann, Carmen; Reiher, Markus; Hess, Bernd A
2005-01-15
This work provides a survey of the definition of electron spin as a local property and its dependence on several parameters in actual calculations. We analyze one-determinant wave functions constructed from Hartree-Fock and, in particular, from Kohn-Sham orbitals within the collinear approach to electron spin. The scalar total spin operators S2 and Sz are partitioned by projection operators, as introduced by Clark and Davidson, in order to obtain local spin operators SASB and SzA, respectively. To complement the work of Davidson and co-workers, we analyze some features of local spins which have not yet been discussed in sufficient depth. The dependence of local spin on the choice of basis set, density functional, and projector is studied. We also discuss the results of Sz partitioning and show that SzA values depend less on these parameters than SASB values. Furthermore, we demonstrate that for small organic test molecules, a partitioning of Sz with preorthogonalized Lowdin projectors yields nearly the same results as one obtains using atoms-in-molecules projectors. In addition, the physical significance of nonzero SASB values for closed-shell molecules is investigated. It is shown that due to this problem, SASB values are useful for calculations of relative spin values, but not for absolute local spins, where SzA values appear to be better suited.
Control of vertical posture while elevating one foot to avoid a real or virtual obstacle.
Ida, Hirofumi; Mohapatra, Sambit; Aruin, Alexander
2017-06-01
The purpose of this study is to investigate the control of vertical posture during obstacle avoidance in a real versus a virtual reality (VR) environment. Ten healthy participants stood upright and lifted one leg to avoid colliding with a real obstacle sliding on the floor toward a participant and with its virtual image. Virtual obstacles were delivered by a head mounted display (HMD) or a 3D projector. The acceleration of the foot, center of pressure, and electrical activity of the leg and trunk muscles were measured and analyzed during the time intervals typical for early postural adjustments (EPAs), anticipatory postural adjustments (APAs), and compensatory postural adjustments (CPAs). The results showed that the peak acceleration of foot elevation in the HMD condition decreased significantly when compared with that of the real and 3D projector conditions. Reduced activity of the leg and trunk muscles was seen when dealing with virtual obstacles (HMD and 3D projector) as compared with that seen when dealing with real obstacles. These effects were more pronounced during APAs and CPAs. The onsets of muscle activities in the supporting limb were seen during EPAs and APAs. The observed modulation of muscle activity and altered patterns of movement seen while avoiding a virtual obstacle should be considered when designing virtual rehabilitation protocols.
Enhancing the radiology learning experience with electronic whiteboard technology.
Lipton, Michael L; Lipton, Leah G
2010-06-01
The purpose of this study is to quantitatively evaluate the use of an interactive whiteboard for use in teaching diagnostic radiology and MRI physics. An interactive whiteboard (SMART Board model 3000i) was used during an MRI physics course and diagnostic radiology teaching conferences. A multiquestion instrument was used to quantify responses. Responses are reported as simple percentages of response number and, for ordinal scale questions, the two-tailed Student's t test was used to assess deviation from the neutral response. All of the subjects attended all sessions and completed the assessment questionnaire; 89% of respondents said that image quality of the SMART Board was superior to that of a projector-screen combination, 11% said that the image quality was similar, and none said that it was inferior. Sixty-seven percent of respondents said that the SMART Board's display of diagrams was superior to that of a conventional whiteboard, 33% said it was similar, and none said it was inferior. Participants thought that the smaller SMART Board display compared with the projector screen was an unimportant limitation (p = 0.03). Room lighting did not degrade image quality (p = 0.007), and a trend toward preference for the lighted room (while using the SMART Board) was detected (p = 0.15) but was not significant. The impact of the SMART Board on the visual material and flow of teaching sessions was favorable (p = 0.005). All of the subjects preferred the SMART Board over a traditional projector and screen combination. Learners endorsed that the SMART Board significantly enhanced learning, universally preferring it to the standard projector and screen approach. Major advantages include enhanced engagement of learners; enhanced integration of images and annotations or diagrams, including display of both images and diagrams simultaneously on a single screen; and the ability to review, revise, save, and distribute diagrams and annotated images. Disadvantages include cost and potentially complicated setup in very large auditoriums.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reuter, Matthew G., E-mail: mgreuter@u.northwestern.edu; Harrison, Robert J.
2014-05-07
The thesis of Brandbyge's comment [J. Chem. Phys. 140, 177103 (2014)] is that our operator decoupling condition is immaterial to transport theories, and it appeals to discussions of nonorthogonal basis sets in transport calculations in its arguments. We maintain that the operator condition is to be preferred over the usual matrix conditions and subsequently detail problems in the existing approaches. From this operator perspective, we conclude that nonorthogonal projectors cannot be used and that the projectors must be selected to satisfy the operator decoupling condition. Because these conclusions pertain to operators, the choice of basis set is not germane.
Method and apparatus for providing a seamless tiled display
NASA Technical Reports Server (NTRS)
Dubin, Matthew B. (Inventor); Johnson, Michael J. (Inventor)
2002-01-01
A display for producing a seamless composite image from at least two discrete images. The display includes one or more projectors for projecting each of the discrete images separately onto a screen such that at least one of the discrete images overlaps at least one other of the discrete images by more than 25 percent. The amount of overlap that is required to reduce the seams of the composite image to an acceptable level over a predetermined viewing angle depends on a number of factors including the field-of-view and aperture size of the projectors, the screen gain profile, etc. For rear-projection screens and some front projection screens, an overlap of more than 25 percent is acceptable.
NASA Astrophysics Data System (ADS)
Kim, Min Young; Cho, Hyung Suck; Kim, Jae H.
2002-10-01
In recent years, intelligent autonomous mobile robots have drawn tremendous interests as service robots for serving human or industrial robots for replacing human. To carry out the task, robots must be able to sense and recognize 3D space that they live or work. In this paper, we deal with the topic related to 3D sensing system for the environment recognition of mobile robots. For this, the structured lighting is basically utilized for a 3D visual sensor system because of the robustness on the nature of the navigation environment and the easy extraction of feature information of interest. The proposed sensing system is classified into a trinocular vision system, which is composed of the flexible multi-stripe laser projector, and two cameras. The principle of extracting the 3D information is based on the optical triangulation method. With modeling the projector as another camera and using the epipolar constraints which the whole cameras makes, the point-to-point correspondence between the line feature points in each image is established. In this work, the principle of this sensor is described in detail, and a series of experimental tests is performed to show the simplicity and efficiency and accuracy of this sensor system for 3D the environment sensing and recognition.
NASA Astrophysics Data System (ADS)
Chen, Chao; Gao, Nan; Wang, Xiangjun; Zhang, Zonghua
2018-05-01
Three-dimensional (3D) shape measurement based on fringe pattern projection techniques has been commonly used in various fields. One of the remaining challenges in fringe pattern projection is that camera sensor saturation may occur if there is a large range of reflectivity variation across the surface that causes measurement errors. To overcome this problem, a novel fringe pattern projection method is proposed to avoid image saturation and maintain high-intensity modulation for measuring shiny surfaces by adaptively adjusting the pixel-to-pixel projection intensity according to the surface reflectivity. First, three sets of orthogonal color fringe patterns and a sequence of uniform gray-level patterns with different gray levels are projected onto a measured surface by a projector. The patterns are deformed with respect to the object surface and captured by a camera from a different viewpoint. Subsequently, the optimal projection intensity at each pixel is determined by fusing different gray levels and transforming the camera pixel coordinate system into the projector pixel coordinate system. Finally, the adapted fringe patterns are created and used for 3D shape measurement. Experimental results on a flat checkerboard and shiny objects demonstrate that the proposed method can measure shiny surfaces with high accuracy.
NASA Astrophysics Data System (ADS)
Satria, E.
2018-03-01
Preservice teachers in primary education should be well equipped to meet the challenges of teaching primary science effectively in 21century. The purpose of this research was to describe the projects for the implementation of Science-Technology-Society (STS) approach in Basic Concept of Natural Science course as application of optical and electrical instruments’ material by the preservice teachers in Elementary Schools Teacher Education Program. One of the reasons is the lack of preservice teachers’ ability in making projects for application of STS approach and optical and electrical instruments’ material in Basic Concept of Natural Science course. This research applied descriptive method. The instrument of the research was the researcher himself. The data were gathered through observation and documentation. Based on the results of the research, it was figured out that preservice teachers, in groups, were creatively and successful to make the projects of optical and electrical instruments assigned such as projector and doorbell. It was suggested that the construction of the instruments should be better (fixed and strong structure) and more attractive for both instruments, and used strong light source, high quality images, and it could use speaker box for projector, power battery, and heat sink for electrical instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hanming; Wang, Linyuan; Li, Lei
2016-06-15
Purpose: Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However, conventional iterative reconstruction methods easily introduce new artifacts around metal implants because of incomplete data reconstruction and inconsistencies in practical data acquisition. Hence, this work aims at developing a method to suppress newly introduced artifacts and improve the image quality around metal implants for the iterative MAR scheme. Methods: The proposed method consists of twomore » steps based on the general iterative MAR framework. An uncorrected image is initially reconstructed, and the corresponding metal trace is obtained. The iterative reconstruction method is then used to reconstruct images from the unaffected sinogram. In the reconstruction step of this work, an iterative strategy utilizing unmatched projector/backprojector pairs is used. A ramp filter is introduced into the back-projection procedure to restrain the inconsistency components in low frequencies and generate more reliable images of the regions around metals. Furthermore, a constrained total variation (TV) minimization model is also incorporated to enhance efficiency. The proposed strategy is implemented based on an iterative FBP and an alternating direction minimization (ADM) scheme, respectively. The developed algorithms are referred to as “iFBP-TV” and “TV-FADM,” respectively. Two projection-completion-based MAR methods and three iterative MAR methods are performed simultaneously for comparison. Results: The proposed method performs reasonably on both simulation and real CT-scanned datasets. This approach could reduce streak metal artifacts effectively and avoid the mentioned effects in the vicinity of the metals. The improvements are evaluated by inspecting regions of interest and by comparing the root-mean-square errors, normalized mean absolute distance, and universal quality index metrics of the images. Both iFBP-TV and TV-FADM methods outperform other counterparts in all cases. Unlike the conventional iterative methods, the proposed strategy utilizing unmatched projector/backprojector pairs shows excellent performance in detail preservation and prevention of the introduction of new artifacts. Conclusions: Qualitative and quantitative evaluations of experimental results indicate that the developed method outperforms classical MAR algorithms in suppressing streak artifacts and preserving the edge structural information of the object. In particular, structures lying close to metals can be gradually recovered because of the reduction of artifacts caused by inconsistency effects.« less
NCAP projection displays: key issues for commercialization
NASA Astrophysics Data System (ADS)
Tomita, Akira; Jones, Philip J.
1992-06-01
Recently there has been much interest in a new polymer nematic dispersion technology, often called as NCAP, PDLC, PNLC, LCPC, etc., since projection displays using this technology have been shown to produce much brighter display images than projectors using conventional twisted nematic (TN) lightvalves. For commercializing projection displays based on this polymer nematic dispersion technology, the new materials must not only meet various electro- optic requirements, e.g., operational voltage, `off-state'' scattering angle, voltage holding ratio and hysteresis, but must also be stable over the lifetime of the product. This paper reports recent progress in the development of NCAP based projection displays and discusses some of the key commercialization issues.
Achieving ultra-high temperatures with a resistive emitter array
NASA Astrophysics Data System (ADS)
Danielson, Tom; Franks, Greg; Holmes, Nicholas; LaVeigne, Joe; Matis, Greg; McHugh, Steve; Norton, Dennis; Vengel, Tony; Lannon, John; Goodwin, Scott
2016-05-01
The rapid development of very-large format infrared detector arrays has challenged the IR scene projector community to also develop larger-format infrared emitter arrays to support the testing of systems incorporating these detectors. In addition to larger formats, many scene projector users require much higher simulated temperatures than can be generated with current technology in order to fully evaluate the performance of their systems and associated processing algorithms. Under the Ultra High Temperature (UHT) development program, Santa Barbara Infrared Inc. (SBIR) is developing a new infrared scene projector architecture capable of producing both very large format (>1024 x 1024) resistive emitter arrays and improved emitter pixel technology capable of simulating very high apparent temperatures. During earlier phases of the program, SBIR demonstrated materials with MWIR apparent temperatures in excess of 1400 K. New emitter materials have subsequently been selected to produce pixels that achieve even higher apparent temperatures. Test results from pixels fabricated using the new material set will be presented and discussed. A 'scalable' Read In Integrated Circuit (RIIC) is also being developed under the same UHT program to drive the high temperature pixels. This RIIC will utilize through-silicon via (TSV) and Quilt Packaging (QP) technologies to allow seamless tiling of multiple chips to fabricate very large arrays, and thus overcome the yield limitations inherent in large-scale integrated circuits. Results of design verification testing of the completed RIIC will be presented and discussed.
System of Programmed Modules for Measuring Photographs with a Gamma-Telescope
NASA Technical Reports Server (NTRS)
Averin, S. A.; Veselova, G. V.; Navasardyan, G. V.
1978-01-01
Physical experiments using tracking cameras resulted in hundreds of thousands of stereo photographs of events being received. To process such a large volume of information, automatic and semiautomatic measuring systems are required. At the Institute of Space Research of the Academy of Science of the USSR, a system for processing film information from the spark gamma-telescope was developed. The system is based on a BPS-75 projector in line with the minicomputer Elektronika 1001. The report describes this system. The various computer programs available to the operators are discussed.
Xia, Xinxing; Zheng, Zhenrong; Liu, Xu; Li, Haifeng; Yan, Caijie
2010-09-10
We utilized a high-frame-rate projector, a rotating mirror, and a cylindrical selective-diffusing screen to present a novel three-dimensional (3D) omnidirectional-view display system without the need for any special viewing aids. The display principle and image size are analyzed, and the common display zone is proposed. The viewing zone for one observation place is also studied. The experimental results verify this method, and a vivid color 3D scene with occlusion and smooth parallax is also demonstrated with the system.
Fiber-optic fringe projection with crosstalk reduction by adaptive pattern masking
NASA Astrophysics Data System (ADS)
Matthias, Steffen; Kästner, Markus; Reithmeier, Eduard
2017-02-01
To enable in-process inspection of industrial manufacturing processes, measuring devices need to fulfill time and space constraints, while also being robust to environmental conditions, such as high temperatures and electromagnetic fields. A new fringe projection profilometry system is being developed, which is capable of performing the inspection of filigree tool geometries, e.g. gearing elements with tip radii of 0.2 mm, inside forming machines of the sheet-bulk metal forming process. Compact gradient-index rod lenses with a diameter of 2 mm allow for a compact design of the sensor head, which is connected to a base unit via flexible high-resolution image fibers with a diameter of 1.7 mm. The base unit houses a flexible DMD based LED projector optimized for fiber coupling and a CMOS camera sensor. The system is capable of capturing up to 150 gray-scale patterns per second as well as high dynamic range images from multiple exposures. Owing to fiber crosstalk and light leakage in the image fiber, signal quality suffers especially when capturing 3-D data of technical surfaces with highly varying reflectance or surface angles. An algorithm is presented, which adaptively masks parts of the pattern to reduce these effects via multiple exposures. The masks for valid surface areas are automatically defined according to different parameters from an initial capture, such as intensity and surface gradient. In a second step, the masks are re-projected to projector coordinates using the mathematical model of the system. This approach is capable of reducing both inter-pixel crosstalk and inter-object reflections on concave objects while maintaining measurement durations of less than 5 s.
LWIR NUC using an uncooled microbolometer camera
NASA Astrophysics Data System (ADS)
Laveigne, Joe; Franks, Greg; Sparkman, Kevin; Prewarski, Marcus; Nehring, Brian; McHugh, Steve
2010-04-01
Performing a good non-uniformity correction is a key part of achieving optimal performance from an infrared scene projector. Ideally, NUC will be performed in the same band in which the scene projector will be used. Cooled, large format MWIR cameras are readily available and have been successfully used to perform NUC, however, cooled large format LWIR cameras are not as common and are prohibitively expensive. Large format uncooled cameras are far more available and affordable, but present a range of challenges in practical use for performing NUC on an IRSP. Santa Barbara Infrared, Inc. reports progress on a continuing development program to use a microbolometer camera to perform LWIR NUC on an IRSP. Camera instability and temporal response and thermal resolution are the main difficulties. A discussion of processes developed to mitigate these issues follows.
Noncommutative de Rham Cohomology of Finite Groups
NASA Astrophysics Data System (ADS)
Castellani, L.; Catenacci, R.; Debernardi, M.; Pagani, C.
We study de Rham cohomology for various differential calculi on finite groups G up to order 8. These include the permutation group S3, the dihedral group D4 and the quaternion group Q. Poincaré duality holds in every case, and under some assumptions (essentially the existence of a top form) we find that it must hold in general. A short review of the bicovariant (noncommutative) differential calculus on finite G is given for selfconsistency. Exterior derivative, exterior product, metric, Hodge dual, connections, torsion, curvature, and biinvariant integration can be defined algebraically. A projector decomposition of the braiding operator is found, and used in constructing the projector on the space of two-forms. By means of the braiding operator and the metric a knot invariant is defined for any finite group.
Fast-responding liquid crystal light-valve technology for color-sequential display applications
NASA Astrophysics Data System (ADS)
Janssen, Peter J.; Konovalov, Victor A.; Muravski, Anatoli A.; Yakovenko, Sergei Y.
1996-04-01
A color sequential projection system has some distinct advantages over conventional systems which make it uniquely suitable for consumer TV as well as high performance professional applications such as computer monitors and electronic cinema. A fast responding light-valve is, clearly, essential for a good performing system. Response speed of transmissive LC lightvalves has been marginal thus far for good color rendition. Recently, Sevchenko Institute has made some very fast reflective LC cells which were evaluated at Philips Labs. These devices showed sub millisecond-large signal-response times, even at room temperature, and produced good color in a projector emulation testbed. In our presentation we describe our highly efficient color sequential projector and demonstrate its operation on video tape. Next we discuss light-valve requirements and reflective light-valve test results.
Planetary Education and Outreach Using the NOAA Science on a Sphere
NASA Technical Reports Server (NTRS)
Simon-Miller, A. A.; Williams, D. R.; Smith, S. M.; Friedlander, J. S.; Mayo, L. A.; Clark, P. E.; Henderson, M. A.
2011-01-01
Science On a Sphere (SOS) is a large visualization system, developed by the National Oceanic and Atmospheric Administration (NOAH), that uses computers running Redhat Linux and four video projectors to display animated data onto the outside of a sphere. Said another way, SOS is a stationary globe that can show dynamic, animated images in spherical form. Visualization of cylindrical data maps show planets, their atmosphere, oceans, and land, in very realistic form. The SOS system uses 4 video projectors to display images onto the sphere. Each projector is driven by a separate computer, and a fifth computer is used to control the operation of the display computers. Each computer is a relatively powerful PC with a high-end graphics card. The video projectors have native XGA resolution. The projectors are placed at the corners of a 30' x 30' square with a 68" carbon fiber sphere suspended in the center of the square. The equator of the sphere is typically located 86" off the floor. SOS uses common image formats such as JPEG, or TIFF in a very specific, but simple form; the images are plotted on an equatorial cylindrical equidistant projection, or as it is commonly known, a latitude/longitude grid, where the image is twice as wide as it is high (rectangular). 2048x] 024 is the minimum usable spatial resolution without some noticeable pixelation. Labels and text can be applied within the image, or using a timestamp-like feature within the SOS system software. There are two basic modes of operation for SOS: displaying a single image or an animated sequence of frames. The frame or frames can be setup to rotate or tilt, as in a planetary rotation. Sequences of images that animate through time produce a movie visualization, with or without an overlain soundtrack. After the images are processed, SOS will display the images in sequence and play them like a movie across the entire sphere surface. Movies can be of any arbitrary length, limited mainly by disk space and can be animated at frame rates up to 30 frames per second. Transitions, special effects, and other computer graphics techniques can be added to a sequence through the use of off-the-shelf software, like Final Cut Pro. However, one drawback is that the Sphere cannot be used in the same manner as a flat movie screen; images cannot be pushed to a "side", a highlighted area must be viewable to all sides of the room simultaneously, and some transitions do not work as well as others. We discuss these issues and workarounds in our poster.
ERIC Educational Resources Information Center
Harpp, David N.; Snyder, James P.
1977-01-01
Describes a lecture teaching technique called lap-dissolve projection in which two slide projectors are operated alternately so that one visual image fades away while the next appears on the same screen area. (MLH)
Structured Light-Based Hazard Detection For Planetary Surface Navigation
NASA Technical Reports Server (NTRS)
Nefian, Ara; Wong, Uland Y.; Dille, Michael; Bouyssounouse, Xavier; Edwards, Laurence; To, Vinh; Deans, Matthew; Fong, Terry
2017-01-01
This paper describes a structured light-based sensor for hazard avoidance in planetary environments. The system presented here can also be used in terrestrial applications constrained by reduced onboard power and computational complexity and low illumination conditions. The sensor is on a calibrated camera and laser dot projector system. The onboard hazard avoidance system determines the position of the projected dots in the image and through a triangulation process detects potential hazards. The paper presents the design parameters for this sensor and describes the image based solution for hazard avoidance. The system presented here was tested extensively in day and night conditions in Lunar analogue environments. The current system achieves over 97 detection rate with 1.7 false alarms over 2000 images.
Demonstrating Forces between Parallel Wires.
ERIC Educational Resources Information Center
Baker, Blane
2000-01-01
Describes a physics demonstration that dramatically illustrates the mutual repulsion (attraction) between parallel conductors using insulated copper wire, wooden dowels, a high direct current power supply, electrical tape, and an overhead projector. (WRM)
NASA Astrophysics Data System (ADS)
Calderín, L.; Karasiev, V. V.; Trickey, S. B.
2017-12-01
As the foundation for a new computational implementation, we survey the calculation of the complex electrical conductivity tensor based on the Kubo-Greenwood (KG) formalism (Kubo, 1957; Greenwood, 1958), with emphasis on derivations and technical aspects pertinent to use of projector augmented wave datasets with plane wave basis sets (Blöchl, 1994). New analytical results and a full implementation of the KG approach in an open-source Fortran 90 post-processing code for use with Quantum Espresso (Giannozzi et al., 2009) are presented. Named KGEC ([K]ubo [G]reenwood [E]lectronic [C]onductivity), the code calculates the full complex conductivity tensor (not just the average trace). It supports use of either the original KG formula or the popular one approximated in terms of a Dirac delta function. It provides both Gaussian and Lorentzian representations of the Dirac delta function (though the Lorentzian is preferable on basic grounds). KGEC provides decomposition of the conductivity into intra- and inter-band contributions as well as degenerate state contributions. It calculates the dc conductivity tensor directly. It is MPI parallelized over k-points, bands, and plane waves, with an option to recover the plane wave processes for their use in band parallelization as well. It is designed to provide rapid convergence with respect to k-point density. Examples of its use are given.
Microfilming for Drafting Students
ERIC Educational Resources Information Center
Bass, Ronald E.
1972-01-01
If you have a 35mm camera, an enlarger or filmstrip projector, and developing equipment you can introduce your drafting students to one of the processes used in the newly emerging field of technical communication.'' (Editor)
ERIC Educational Resources Information Center
White, A. S.
1976-01-01
Describes a simple water channel, for use with an overhead projector. It is run from a water tap and may be used for flow visualization experiments, including the effect of streamlining and elementary building aerodynamics. (MLH)
More Fun with Singing Wineglasses.
ERIC Educational Resources Information Center
Planinsic, Gorazd
2000-01-01
Describes a method for visually demonstrating resonance in a wine glass on an overhead projector. Provides instructions for making a "howling" wine glass where two slightly different tones separated by an irritating interval sound alternately. (WRM)
Projector Center. What Is Biotechnology?
ERIC Educational Resources Information Center
Belzer, Bill; Case, Christine L.
1990-01-01
Presented is a menu designed to illustrate some classical examples of fermentation. This may be used to discuss biotechnology from a technological perspective. Other examples of biotechnology used in the foods industry are described. (CW)
Proper Use of Audio-Visual Aids: Essential for Educators.
ERIC Educational Resources Information Center
Dejardin, Conrad
1989-01-01
Criticizes educators as the worst users of audio-visual aids and among the worst public speakers. Offers guidelines for the proper use of an overhead projector and the development of transparencies. (DMM)
BRST technique for the cosmological density matrix
NASA Astrophysics Data System (ADS)
Barvinsky, A. O.
2013-10-01
The microcanonical density matrix in closed cosmology has a natural definition as a projector on the space of solutions of Wheeler-DeWitt equations, which is motivated by the absence of global non-vanishing charges and energy in spatially closed gravitational systems. Using the BRST/BFV formalism in relativistic phase space of gauge and ghost variables we derive the path integral representation for this projector and the relevant statistical sum. This derivation circumvents the difficulties associated with the open algebra of noncommutative quantum Dirac constraints and the construction/regularization of the physical inner product in the subspace of BRS singlets. This inner product is achieved via the Batalin-Marnelius gauge fixing in the space of BRS-invariant states, which in its turn is shown to be a result of truncation of the BRST/BFV formalism to the "matter" sector of relativistic phase space.
Spatial uniformity inspection apparatus for solar cells using a projection display.
Yoo, Jae-Keun; Kim, Seung Kwan; Lee, Dong-Hoon; Park, Seung-Nam
2012-07-10
We demonstrate a measurement apparatus to inspect spatial uniformity of quantum efficiency of solar cells using a beam projector. Deviation of irradiance from the used beam projector over the area of 1.5×0.8 m on the cell plane was flattened within ±2.6% through gray scale adjustment, which was originally about 200%. Scanning a small square image with an area of 3×3 mm over a square-shaped photovoltaic cell with an area of 15.6×15.6 cm, we could identify the locations according to efficiency level and showed that the cell had quantum efficiency deviation of more than 10%. Utilizing the advantageous feature of a projection display, we also demonstrated that this apparatus can inspect the spatial uniformity of solar modules and panels consisting of multiple solar cells.
Determination of NMR chemical shifts for cholesterol crystals from first-principles
NASA Astrophysics Data System (ADS)
Kucukbenli, Emine; de Gironcoli, Stefano
2011-03-01
Solid State Nuclear Magnetic Resonance (NMR) is a powerful tool in crystallography when combined with theoretical predictions. So far, empirical calculations of spectra have been employed for an unambiguous identification. However, many complex systems are outside the scope of these methods. Our implementation of ultrasoft and projector augmented wave pseudopotentials within ab initio gauge including projector augmented plane wave (GIPAW) method in Quantum Espresso simulation package allows affordable calculations of NMR spectra for systems of thousands of electrons. We report here the first ab initio determination of NMR spectra for several crystal structures of cholesterol. Cholesterol crystals, the main component of human gallstones, are of interest to medical research as their structural properties can shed light on the pathologies of gallbladder. With our application we show that ab initio calculations can be employed to aid NMR crystallography.
Interactive display system having a digital micromirror imaging device
Veligdan, James T.; DeSanto, Leonard; Kaull, Lisa; Brewster, Calvin
2006-04-11
A display system includes a waveguide optical panel having an inlet face and an opposite outlet face. A projector cooperates with a digital imaging device, e.g. a digital micromirror imaging device, for projecting an image through the panel for display on the outlet face. The imaging device includes an array of mirrors tiltable between opposite display and divert positions. The display positions reflect an image light beam from the projector through the panel for display on the outlet face. The divert positions divert the image light beam away from the panel, and are additionally used for reflecting a probe light beam through the panel toward the outlet face. Covering a spot on the panel, e.g. with a finger, reflects the probe light beam back through the panel toward the inlet face for detection thereat and providing interactive capability.
Towards Robust Self-Calibration for Handheld 3d Line Laser Scanning
NASA Astrophysics Data System (ADS)
Bleier, M.; Nüchter, A.
2017-11-01
This paper studies self-calibration of a structured light system, which reconstructs 3D information using video from a static consumer camera and a handheld cross line laser projector. Intersections between the individual laser curves and geometric constraints on the relative position of the laser planes are exploited to achieve dense 3D reconstruction. This is possible without any prior knowledge of the movement of the projector. However, inaccurrately extracted laser lines introduce noise in the detected intersection positions and therefore distort the reconstruction result. Furthermore, when scanning objects with specular reflections, such as glossy painted or metalic surfaces, the reflections are often extracted from the camera image as erroneous laser curves. In this paper we investiagte how robust estimates of the parameters of the laser planes can be obtained despite of noisy detections.
Impact of various lecture delivery methods in pharmacology
Seth, Vikas; Upadhyaya, Prerna; Ahmad, Mushtaq; Kumar, Virendra
2010-01-01
The aim of the study was to assess the impact of three common lecture delivery methods viz. the lectures using chalkboard, the lectures using PowerPoint presentations and the lectures utilizing transparencies with an overhead projector. By filling in a questionnaire, the second year MBBS students were asked to assess the impact of three pharmacology lectures given by three different methods of lecture delivery. Also after each lecture an objective test was given to compare the impact of the lecture delivered by different methods. The results of the study show that as per the subjective assessment of the lectures, students preferred PowerPoint teaching the most. As far as the students' performance is concerned the impact of traditional Chalkboard and PowerPoint teaching was much more than the lectures using transparency and overhead projector (OHP). PMID:29255392
Synesthetic colors induced by graphemes that have not been consciously perceived.
Ramachandran, V S; Seckel, Elizabeth
2015-01-01
Grapheme-color synesthetes experience colors when they see printed letters of the alphabet. Currently, we tested four "projector" synesthetes, whose colors evoked by graphemes have sensory support or quale and appear to be restricted spatially to the letters like real colors. We use three different kinds of puzzle pictures that contained hidden letters, which require 30 s or more for nonsynesthetes to identify. Grapheme-color projector synesthetes recognize them three times faster and report that the colors were evoked before conscious letter recognition, clueing them as to what the letters were. Subjectively, the synesthetic subjects reported that they also saw mirror-reversed letters in the same colors as nonreversed letters which enabled them to read mirror-reversed text at thrice the normal speed. We conclude that in some synesthetes colors are evoked preconsciously early in sensory processing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caravelli, Francesco
The dynamics of purely memristive circuits has been shown to depend on a projection operator which expresses the Kirchhoff constraints, is naturally non-local in nature, and does represent the interaction between memristors. In the present paper we show that for the case of planar circuits, for which a meaningful Hamming distance can be defined, the elements of such projector can be bounded by exponentially decreasing functions of the distance. We provide a geometrical interpretation of the projector elements in terms of determinants of Dirichlet Laplacian of the dual circuit. For the case of linearized dynamics of the circuit for whichmore » a solution is known, this can be shown to provide a light cone bound for the interaction between memristors. Furthermore, this result establishes a finite speed of propagation of signals across the network, despite the non-local nature of the system.« less
NASA Astrophysics Data System (ADS)
Sakaguchi, Toshimasa; Fujigaki, Motoharu; Murata, Yorinobu
2015-03-01
Accurate and wide-range shape measurement method is required in industrial field. The same technique is possible to be used for a shape measurement of a human body for the garment industry. Compact 3D shape measurement equipment is also required for embedding in the inspection system. A shape measurement by a phase shifting method can measure the shape with high spatial resolution because the coordinates can be obtained pixel by pixel. A key-device to develop compact equipment is a grating projector. Authors developed a linear LED projector and proposed a light source stepping method (LSSM) using the linear LED projector. The shape measurement euipment can be produced with low-cost and compact without any phase-shifting mechanical systems by using this method. Also it enables us to measure 3D shape in very short time by switching the light sources quickly. A phase unwrapping method is necessary to widen the measurement range with constant accuracy for phase shifting method. A general phase unwrapping method with difference grating pitches is often used. It is one of a simple phase unwrapping method. It is, however, difficult to apply the conventional phase unwrapping algorithm to the LSSM. Authors, therefore, developed an expansion unwrapping algorithm for the LSSM. In this paper, an expansion algorithm of measurement range suited for 3D shape measurement using two pitches of projected grating with the LSSM was evaluated.
Touchscreen everywhere: on transferring a normal planar surface to a touch-sensitive display.
Dai, Jingwen; Chung, Chi-Kit Ronald
2014-08-01
We address how a human-computer interface with small device size, large display, and touch-input facility can be made possible by a mere projector and camera. The realization is through the use of a properly embedded structured light sensing scheme that enables a regular light-colored table surface to serve the dual roles of both a projection screen and a touch-sensitive display surface. A random binary pattern is employed to code structured light in pixel accuracy, which is embedded into the regular projection display in a way that the user perceives only regular display but not the structured pattern hidden in the display. With the projection display on the table surface being imaged by a camera, the observed image data, plus the known projection content, can work together to probe the 3-D workspace immediately above the table surface, like deciding if there is a finger present and if the finger touches the table surface, and if so, at what position on the table surface the contact is made. All the decisions hinge upon a careful calibration of the projector-camera-table surface system, intelligent segmentation of the hand in the image data, and exploitation of the homography mapping existing between the projector's display panel and the camera's image plane. Extensive experimentation including evaluation of the display quality, hand segmentation accuracy, touch detection accuracy, trajectory tracking accuracy, multitouch capability and system efficiency are shown to illustrate the feasibility of the proposed realization.
Pilot estimates of glidepath and aim point during simulated landing approaches
NASA Technical Reports Server (NTRS)
Acree, C. W., Jr.
1981-01-01
Pilot perceptions of glidepath angle and aim point were measured during simulated landings. A fixed-base cockpit simulator was used with video recordings of simulated landing approaches shown on a video projector. Pilots estimated the magnitudes of approach errors during observation without attempting to make corrections. Pilots estimated glidepath angular errors well, but had difficulty estimating aim-point errors. The data make plausible the hypothesis that pilots are little concerned with aim point during most of an approach, concentrating instead on keeping close to the nominal glidepath and trusting this technique to guide them to the proper touchdown point.
High-speed measurements of steel-plate deformations during laser surface processing.
Jezersek, Matija; Gruden, Valter; Mozina, Janez
2004-10-04
In this paper we present a novel approach to monitoring the deformations of a steel plate's surface during various types of laser processing, e.g., engraving, marking, cutting, bending, and welding. The measuring system is based on a laser triangulation principle, where the laser projector generates multiple lines simultaneously. This enables us to measure the shape of the surface with a high sampling rate (80 Hz with our camera) and high accuracy (+/-7 microm). The measurements of steel-plate deformations for plates of different thickness and with different illumination patterns are presented graphically and in an animation.
Quickly creating interactive astronomy illustrations
NASA Astrophysics Data System (ADS)
Slater, Timothy F.
2015-01-01
An innate advantage for astronomy teachers is having numerous breathtaking images of the cosmos available to capture students' curiosity, imagination, and wonder. Internet-based astronomy image libraries are numerous and easy to navigate. The Astronomy Picture of the Day, the Hubble Space Telescope image archive, and the NASA Planetary Photojournal are just a few of the many available.1-3 At the same time, computer video projectors and SMART Boards are becoming ever more commonplace in classrooms. Taken together, it has never been easier to bring astronomy directly into classrooms to actively engage students to improve student understanding and motivate student learning.
"Black Magic": Pepper in a Magnetic Field
ERIC Educational Resources Information Center
Peterson, John E.
1977-01-01
Describes a procedure to demonstrate the effect of a magnetic force on a moving charge. The materials used are inexpensive and with the use of an overhead projector, easily visible to an entire class. (CP)
ERIC Educational Resources Information Center
School Science Review, 1980
1980-01-01
Describes equipment, activities, and experiments useful in biology and environmental education instruction, including, among others, sampling in ecology using an overhead projector, the slide finder as an aid to microscopy, teaching kidney function, and teaching wildlife conservation-sand dune systems. (SK)
Modems and More: The Computer Branches Out.
ERIC Educational Resources Information Center
Dyrli, Odvard Egil
1986-01-01
Surveys new "peripherals," electronic devices that attach to computers. Devices such as videodisc players, desktop laser printers, large screen projectors, and input mechanisms that circumvent the keyboard dramatically expand the computer's instructional uses. (Author/LHW)
Chiral Bosonization of Superconformal Ghosts
NASA Technical Reports Server (NTRS)
Shi, Deheng; Shen, Yang; Liu, Jinling; Xiong, Yongjian
1996-01-01
We explain the difference of the Hilbert space of the superconformal ghosts (beta,gamma) system from that of its bosonized fields phi and chi. We calculate the chiral correlation functions of phi, chi fields by inserting appropriate projectors.
76 FR 49782 - Notice of Issuance of Final Determination Concerning Certain Digital Projectors
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-11
... from an electronically erasable programmable read only memory (EEPROM). The firmware detects the power..., Harmonized Tariff Schedule of the United States), the programming of a foreign PROM (Programmable Read-Only...
Web-based interventions for menopause: A systematic integrated literature review.
Im, Eun-Ok; Lee, Yaelim; Chee, Eunice; Chee, Wonshik
2017-01-01
Advances in computer and Internet technologies have allowed health care providers to develop, use, and test various types of Web-based interventions for their practice and research. Indeed, an increasing number of Web-based interventions have recently been developed and tested in health care fields. Despite the great potential for Web-based interventions to improve practice and research, little is known about the current status of Web-based interventions, especially those related to menopause. To identify the current status of Web-based interventions used in the field of menopause, a literature review was conducted using multiple databases, with the keywords "online," "Internet," "Web," "intervention," and "menopause." Using these keywords, a total of 18 eligible articles were analyzed to identify the current status of Web-based interventions for menopause. Six themes reflecting the current status of Web-based interventions for menopause were identified: (a) there existed few Web-based intervention studies on menopause; (b) Web-based decision support systems were mainly used; (c) there was a lack of detail on the interventions; (d) there was a lack of guidance on the use of Web-based interventions; (e) counselling was frequently combined with Web-based interventions; and (f) the pros and cons were similar to those of Web-based methods in general. Based on these findings, directions for future Web-based interventions for menopause are provided. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
High-speed real-time image compression based on all-optical discrete cosine transformation
NASA Astrophysics Data System (ADS)
Guo, Qiang; Chen, Hongwei; Wang, Yuxi; Chen, Minghua; Yang, Sigang; Xie, Shizhong
2017-02-01
In this paper, we present a high-speed single-pixel imaging (SPI) system based on all-optical discrete cosine transform (DCT) and demonstrate its capability to enable noninvasive imaging of flowing cells in a microfluidic channel. Through spectral shaping based on photonic time stretch (PTS) and wavelength-to-space conversion, structured illumination patterns are generated at a rate (tens of MHz) which is three orders of magnitude higher than the switching rate of a digital micromirror device (DMD) used in a conventional single-pixel camera. Using this pattern projector, high-speed image compression based on DCT can be achieved in the optical domain. In our proposed system, a high compression ratio (approximately 10:1) and a fast image reconstruction procedure are both achieved, which implicates broad applications in industrial quality control and biomedical imaging.
Beats: Video Monitors and Cameras.
ERIC Educational Resources Information Center
Worth, Frazier
1996-01-01
Presents a method to teach the concept of beats as a generalized phenomenon rather than teaching it only in the context of sound. Involves using a video camera to film a computer terminal, 16-mm projector, or TV monitor. (JRH)
ERIC Educational Resources Information Center
Wright, Emmett L.
1979-01-01
A demonstration is described that encourages students to engage in inquiry in biology. Using chemicals and an overhead projector, the instructor can simulate a living organism projected onto a screen. The reaction can aid students in defining the characteristics of life. (SA)
The Blue Bottle Experiment--Simple Demonstration of Self-Organization.
ERIC Educational Resources Information Center
Adamcikova, L'ubica; Sevcik, Peter
1998-01-01
Explains a way of observing pattern formation in the Blue Bottle chemistry demonstration by pouring a solution containing sodium hydroxide, glucose, and dye into a Petri dish and placing the dish on an overhead projector. (WRM)
A New Idea for Dissecting Tray
ERIC Educational Resources Information Center
Branham, Arthur
1976-01-01
A method of preparing a special dissecting tray to be used with transmitted light as well as reflected light is presented. It may also be used with an overhead projector to illustrate some skeletal structures in vertebrates. (Author/EB)
NASA Astrophysics Data System (ADS)
Xu, Xiao; Holzwarth, N. A. W.
2011-10-01
This paper presents the formulation and numerical implementation of a self-consistent treatment of orbital-dependent exchange-correlation functionals within the projector-augmented-wave method of Blöchl [Phys. Rev. BPRBMDO1098-012110.1103/PhysRevB.50.17953 50, 17953 (1994)] for electronic structure calculations. The methodology is illustrated with binding energy curves for C in the diamond structure and LiF in the rock salt structure, by comparing results from the Hartree-Fock (HF) formalism and the optimized effective potential formalism in the so-called KLI approximation [Krieger, Li, and Iafrate, Phys. Rev. APLRAAN1050-294710.1103/PhysRevA.45.101 45, 101 (1992)] with those of the local density approximation. While the work here uses pure Fock exchange only, the formalism can be extended to treat orbital-dependent functionals more generally.
Design and analysis of reflector for uniform light-emitting diode illuminance.
Tsai, Chung-Yu
2013-05-01
A light-emitting diode (LED) projection system is proposed, composed of an LED chip and a variable-focus-parabolic (VFP) reflector, in which the focal length varies as a function of the vertical displacement of the incidence point relative to the horizontal centerline of the LED chip. The light-ray paths within the projection system are analyzed using an exact analytical model and a skew-ray tracing approach. The profile of the proposed VFP reflector and the position of the LED chip are then optimized in such a way as to enhance the uniformity of the illuminance distribution on the target region of the image plane. The validity of the optimized design is demonstrated by means of ZEMAX simulations. It is shown that the optimized VFP projector system yields a significant improvement in illuminance uniformity compared to conventional spherical and parabolic projectors and therefore minimizes the glare effect.
Three-dimensional hologram display system
NASA Technical Reports Server (NTRS)
Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)
2009-01-01
The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.
Design of a linear projector for use with the normal modes of the GLAS 4th order GCM
NASA Technical Reports Server (NTRS)
Bloom, S. C.
1984-01-01
The design of a linear projector for use with the normal modes of a model of atmospheric circulation is discussed. A central element in any normal mode initialization scheme is the process by which a set of data fields - winds, temperatures or geopotentials, and surface pressures - are expressed ("projected') in terms of the coefficients of a model's normal modes. This process is completely analogous to the Fourier decomposition of a single field (indeed a FFT applied in the zonal direction is a part of the process). Complete separability in all three spatial dimensions is assumed. The basis functions for the modal expansion are given. An important feature of the normal modes is their coupling of the structures of different fields, thus a coefficient in a normal mode expansion would contain both mass and momentum information.
Quality status display for a vibration welding process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spicer, John Patrick; Abell, Jeffrey A.; Wincek, Michael Anthony
A method includes receiving, during a vibration welding process, a set of sensory signals from a collection of sensors positioned with respect to a work piece during formation of a weld on or within the work piece. The method also includes receiving control signals from a welding controller during the process, with the control signals causing the welding horn to vibrate at a calibrated frequency, and processing the received sensory and control signals using a host machine. Additionally, the method includes displaying a predicted weld quality status on a surface of the work piece using a status projector. The methodmore » may include identifying and display a quality status of a suspect weld. The laser projector may project a laser beam directly onto or immediately adjacent to the suspect welds, e.g., as a red, green, blue laser or a gas laser having a switched color filter.« less
Locality of interactions for planar memristive circuits
Caravelli, Francesco
2017-11-08
The dynamics of purely memristive circuits has been shown to depend on a projection operator which expresses the Kirchhoff constraints, is naturally non-local in nature, and does represent the interaction between memristors. In the present paper we show that for the case of planar circuits, for which a meaningful Hamming distance can be defined, the elements of such projector can be bounded by exponentially decreasing functions of the distance. We provide a geometrical interpretation of the projector elements in terms of determinants of Dirichlet Laplacian of the dual circuit. For the case of linearized dynamics of the circuit for whichmore » a solution is known, this can be shown to provide a light cone bound for the interaction between memristors. Furthermore, this result establishes a finite speed of propagation of signals across the network, despite the non-local nature of the system.« less
NASA Astrophysics Data System (ADS)
Brecher, Kenneth
2006-12-01
Project LITE (Light Inquiry Through Experiments) is a materials, software, and curriculum development project. It focuses on light, optics, color and visual perception. According to two recent surveys of college astronomy faculty members, these are among the topics most often included in the large introductory astronomy courses. The project has aimed largely at the design and implementation of hands-on experiences for students. However, it has also included the development of lecture demonstrations that employ novel light sources and materials. In this presentation, we will show some of our new lecture demonstrations concerning geometrical and physical optics, fluorescence, phosphorescence and polarization. We have developed over 200 Flash and Java applets that can be used either by teachers in lecture settings or by students at home. They are all posted on the web at http://lite.bu.edu. For either purpose they can be downloaded directly to the user's computer or run off line. In lecture demonstrations, some of these applets can be used to control the light emitted by video projectors to produce physical effects in materials (e.g. fluorescence). Other applets can be used, for example, to demonstrate that the human percept of color does not have a simple relationship with the physical frequency of the stimulating source of light. Project LITE is supported by Grant #DUE-0125992 from the NSF Division of Undergraduate Education.
Mitra, Ayan; Politte, David G; Whiting, Bruce R; Williamson, Jeffrey F; O'Sullivan, Joseph A
2017-01-01
Model-based image reconstruction (MBIR) techniques have the potential to generate high quality images from noisy measurements and a small number of projections which can reduce the x-ray dose in patients. These MBIR techniques rely on projection and backprojection to refine an image estimate. One of the widely used projectors for these modern MBIR based technique is called branchless distance driven (DD) projection and backprojection. While this method produces superior quality images, the computational cost of iterative updates keeps it from being ubiquitous in clinical applications. In this paper, we provide several new parallelization ideas for concurrent execution of the DD projectors in multi-GPU systems using CUDA programming tools. We have introduced some novel schemes for dividing the projection data and image voxels over multiple GPUs to avoid runtime overhead and inter-device synchronization issues. We have also reduced the complexity of overlap calculation of the algorithm by eliminating the common projection plane and directly projecting the detector boundaries onto image voxel boundaries. To reduce the time required for calculating the overlap between the detector edges and image voxel boundaries, we have proposed a pre-accumulation technique to accumulate image intensities in perpendicular 2D image slabs (from a 3D image) before projection and after backprojection to ensure our DD kernels run faster in parallel GPU threads. For the implementation of our iterative MBIR technique we use a parallel multi-GPU version of the alternating minimization (AM) algorithm with penalized likelihood update. The time performance using our proposed reconstruction method with Siemens Sensation 16 patient scan data shows an average of 24 times speedup using a single TITAN X GPU and 74 times speedup using 3 TITAN X GPUs in parallel for combined projection and backprojection.
Shape-Dependent Optoelectronic Cell Lysis**
Kremer, Clemens; Witte, Christian; Neale, Steven L; Reboud, Julien; Barrett, Michael P; Cooper, Jonathan M
2014-01-01
We show an electrical method to break open living cells amongst a population of different cell types, where cell selection is based upon their shape. We implement the technique on an optoelectronic platform, where light, focused onto a semiconductor surface from a video projector creates a reconfigurable pattern of electrodes. One can choose the area of cells to be lysed in real-time, from single cells to large areas, simply by redrawing the projected pattern. We show that the method, based on the “electrical shadow” that the cell casts, allows the detection of rare cell types in blood (including sleeping sickness parasites), and has the potential to enable single cell studies for advanced molecular diagnostics, as well as wider applications in analytical chemistry. PMID:24402800
A Wave Diagnostics in Geophysics: Algorithmic Extraction of Atmosphere Disturbance Modes
NASA Astrophysics Data System (ADS)
Leble, S.; Vereshchagin, S.
2018-04-01
The problem of diagnostics in geophysics is discussed and a proposal based on dynamic projecting operators technique is formulated. The general exposition is demonstrated by an example of symbolic algorithm for the wave and entropy modes in the exponentially stratified atmosphere. The novel technique is developed as a discrete version for the evolution operator and the corresponding projectors via discrete Fourier transformation. Its explicit realization for directed modes in exponential one-dimensional atmosphere is presented via the correspondent projection operators in its discrete version in terms of matrices with a prescribed action on arrays formed from observation tables. A simulation based on opposite directed (upward and downward) wave train solution is performed and the modes' extraction from a mixture is illustrated.
3D printing of natural organic materials by photochemistry
NASA Astrophysics Data System (ADS)
Da Silva Gonçalves, Joyce Laura; Valandro, Silvano Rodrigo; Wu, Hsiu-Fen; Lee, Yi-Hsiung; Mettra, Bastien; Monnereau, Cyrille; Schmitt Cavalheiro, Carla Cristina; Pawlicka, Agnieszka; Focsan, Monica; Lin, Chih-Lang; Baldeck, Patrice L.
2016-03-01
In previous works, we have used two-photon induced photochemistry to fabricate 3D microstructures based on proteins, anti-bodies, and enzymes for different types of bio-applications. Among them, we can cite collagen lines to guide the movement of living cells, peptide modified GFP biosensing pads to detect Gram positive bacteria, anti-body pads to determine the type of red blood cells, and trypsin columns in a microfluidic channel to obtain a real time biochemical micro-reactor. In this paper, we report for the first time on two-photon 3D microfabrication of DNA material. We also present our preliminary results on using a commercial 3D printer based on a video projector to polymerize slicing layers of gelatine-objects.
Performance of NCAP projection displays
NASA Astrophysics Data System (ADS)
Jones, Philip J.; Tomita, Akira; Wartenberg, Mark
1991-08-01
Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krempien, Robert; Hoppe, Harald; Kahrs, Lueder
Purpose: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. Methods and Materials: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. Results: In a first clinical study,more » we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). Conclusions: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.« less
Overhead Projector Demonstrations.
ERIC Educational Resources Information Center
Kolb, Doris, Ed.
1989-01-01
Described are three chemistry demonstrations: (1) a simple qualitative technique for taste pattern recognition in structure-activity relationships; (2) a microscale study of gaseous diffusion using bleach, HCl, ammonia, and phenolphthalein; and (3) the rotation of polarized light by stereoisomers of limonene. (MVL)
Tinkertoy Color-Addition Device.
ERIC Educational Resources Information Center
Ferguson, Joe L.
1995-01-01
Describes construction and use of a simple home-built device, using an overhead projector, for use in demonstrations of the addition of various combinations of red, green, and blue light. Useful in connection with discussions of color, color vision, or color television. (JRH)
ERIC Educational Resources Information Center
Fine, Leonard W.; And Others
1977-01-01
Discusses the use of lap-dissolve projection to give students pre-laboratory instruction on an upcoming experiment. In this technique, two slide projectors are operated alternately so that one visual image fades away while the next appears on the same screen area. (MLH)
Redesigning Instruction through Web-based Course Authoring Tools.
ERIC Educational Resources Information Center
Dabbagh, Nada H.; Schmitt, Jeff
1998-01-01
Examines the pedagogical implications of redesigning instruction for Web-based delivery through a case study of an undergraduate computer science course. Initially designed for a traditional learning environment, this course transformed to a Web-based course using WebCT, a Web-based course authoring tool. Discusses the specific features of WebCT.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Jijun; Electronics and Photonics Research Institute, National Institute of Advanced Industrial Science and Technology; Akimoto, Ryoichi, E-mail: r-akimoto@aist.go.jp
2015-10-19
Low threshold current ridge-waveguide BeZnCdSe quantum-well laser diodes (LDs) have been developed by completely etching away the top p-type BeMgZnSe/ZnSe:N short-period superlattice cladding layer, which can suppress the leakage current that flows laterally outside of the electrode. The waveguide LDs are covered with a thick SiO{sub 2} layer and planarized with chemical-mechanical polishing and a reactive ion etching process. Room-temperature lasing under continuous-wave condition is achieved with the laser cavity formed by the cleaved waveguide facets coated with high-reflectivity dielectric films. For a 4 μm-wide green LD lasing around a wavelength of 535 nm, threshold current and voltage of 7.07 mA and 7.89 Vmore » are achieved for a cavity length of 300 μm, and the internal differential quantum efficiency, internal absorption loss, gain constant, and nominal transparency current density are estimated to be 27%, 4.09 cm{sup −1}, 29.92 (cm × μm)/kA and 6.35 kA/(cm{sup 2 }× μm), respectively. This compact device can realize a significantly improved performance with much lower threshold power consumption, which would benefit the potential application for ZnSe-based green LDs as light sources in full-color display and projector devices installed in consumer products such as pocket projectors.« less
Design and evaluation of web-based image transmission and display with different protocols
NASA Astrophysics Data System (ADS)
Tan, Bin; Chen, Kuangyi; Zheng, Xichuan; Zhang, Jianguo
2011-03-01
There are many Web-based image accessing technologies used in medical imaging area, such as component-based (ActiveX Control) thick client Web display, Zerofootprint thin client Web viewer (or called server side processing Web viewer), Flash Rich Internet Application(RIA) ,or HTML5 based Web display. Different Web display methods have different peformance in different network environment. In this presenation, we give an evaluation on two developed Web based image display systems. The first one is used for thin client Web display. It works between a PACS Web server with WADO interface and thin client. The PACS Web server provides JPEG format images to HTML pages. The second one is for thick client Web display. It works between a PACS Web server with WADO interface and thick client running in browsers containing ActiveX control, Flash RIA program or HTML5 scripts. The PACS Web server provides native DICOM format images or JPIP stream for theses clients.
ERIC Educational Resources Information Center
Eaton, Bruce G., Ed.
1981-01-01
Describes experiments and apparatus to: (1) allow astronomy students to test resolution limit of their eyes at several wavelengths; (2) analyze laser mode phases by interferometry; (3) demonstrate a Cartesian diver with an overhead projector; and (4) generate conical beams of light for smoke-chamber demonstrations. (JN)
NASA Astrophysics Data System (ADS)
Arciniegas, Javier R.; González, Andrés. L.; Quintero, L. A.; Contreras, Carlos R.; Meneses, Jaime E.
2014-05-01
Three-dimensional shape measurement is a subject that consistently produces high scientific interest and provides information for medical, industrial and investigative applications, among others. In this paper, it is proposed to implement a three-dimensional (3D) reconstruction system for applications in superficial inspection of non-metallic pipes for the hydrocarbons transport. The system is formed by a CCD camera, a video-projector and a laptop and it is based on fringe projection technique. System functionality is evidenced by evaluating the quality of three-dimensional reconstructions obtained, which allow observing the failures and defects on the study object surface.
Fabrication of corner cube array retro-reflective structure with DLP-based 3D printing technology
NASA Astrophysics Data System (ADS)
Riahi, Mohammadreza
2016-06-01
In this article, the fabrication of a corner cube array retro-reflective structure is presented by using DLP-based 3D printing technology. In this additive manufacturing technology a pattern of a cube corner array is designed in a computer and sliced with specific software. The image of each slice is then projected from the bottom side of a reservoir, containing UV cure resin, utilizing a DLP video projector. The projected area is cured and attached to a base plate. This process is repeated until the entire part is made. The best orientation of the printing process and the effect of layer thicknesses on the surface finish of the cube has been investigated. The thermal reflow surface finishing and replication with soft molding has also been presented in this article.
Web-based learning in professional development: experiences of Finnish nurse managers.
Korhonen, Teija; Lammintakanen, Johanna
2005-11-01
The aim of this article is to describe the nurse managers' expectations, attitudes and experiences on web-based learning before and after participation in a web-based course. Information technology has rapidly become more common in health care settings. However, little is known about nurse managers' experiences on web-based learning, although they have a crucial role in promoting the professional development of their staff. Diagnostic assignments (n = 18) written before and interviews (n = 8) taken after the web-based education. The data were analysed by inductive content analysis. Nurse managers found web-based education to be a suitable and modern method of learning. On the basis of their experience they found multiple ways to utilize web-based learning environments in health care. Information technology skills, equipment, support and time were considered essential in web-based learning. Additionally, they found that their own experience might lead to more widespread implementation of web-based learning in health care settings. Information technology skills of nurse managers and staff need to be developed in order to use information technology effectively. In order to learn in a web-based environment, everyone needs the opportunity and access to required resources. Additionally, nurse managers' own experiences are important to promote wider utilization of web-based learning.
ELECTRO-OPTIC PROJECTOR STUDY.
The report describes research and development tasks undertaken in the development of a Pockels Effect electro - optic light valve. Two reflex...lens electron optics are used in different configurations. The electro - optic crystal utilized was KD2PO4 and when operated in a reflex mode provides
Raduga experiment: Multizonal photographing the Earth from the Soyuz-22 spacecraft
NASA Technical Reports Server (NTRS)
Ziman, Y.; Chesnokov, Y.; Dunayev, B.; Aksenov, V.; Bykovskiy, V.; Ioaskhim, R.; Myuller, K.; Choppe, V.; Volter, V.
1980-01-01
The main results of the scientific research and 'Raduga' experiment are reported. Technical parameters are presented for the MKF-6 camera and the MSP-4 projector. Characteristics of the obtained materials and certain results of their processing are reported.
Overhead Projector Demonstrations.
ERIC Educational Resources Information Center
Kolb, Doris, Ed.
1988-01-01
Provides two demonstrations: (1) electrolyte migration of ions using colored ions which cross a strip of gelatin allowing for noticeable migration; and (2) photochemical reduction of Fe+3 by the citrate ion. Points out both reactions can be done in a Petri dish using common lab materials. (MVL)
Four Versatile Metal Reactions.
ERIC Educational Resources Information Center
Hearn, Barbara C.
1988-01-01
Presents several strategies to teach the reactivity of metal elements. Stresses the safety aspects of these demonstrations using an overhead projector and a plexiglass safety shield. Lists some of the essential learnings desired in these activities. Includes a chart of the activity series of metals. (CW)
ERIC Educational Resources Information Center
Grayson, Katherine
2007-01-01
In November 2006, the editors of "Campus Technology" launched their first-ever High-Resolution Projection Study, to find out if the latest in projector technology could really make a significant difference in teaching, learning, and educational innovation on US campuses. The author and her colleagues asked campus educators,…
Three-dimensional digital projection in neurosurgical education: technical note.
Martins, Carolina; Ribas, Eduardo Carvalhal; Rhoton, Albert L; Ribas, Guilherme Carvalhal
2015-10-01
Three-dimensional images have become an important tool in teaching surgical anatomy, and its didactic power is enhanced when combined with 3D surgical images and videos. This paper describes the method used by the last author (G.C.R.) since 2002 to project 3D anatomical and surgical images using a computer source. Projecting 3D images requires the superposition of 2 similar but slightly different images of the same object. The set of images, one mimicking the view of the left eye and the other mimicking the view of the right eye, constitute the stereoscopic pair and can be processed using anaglyphic or horizontal-vertical polarization of light for individual use or presentation to larger audiences. Classically, 3D projection could be obtained by using a double set of slides, projected through 2 slide projectors, each of them equipped with complementary filters, shooting over a medium that keeps light polarized (a silver screen) and having the audience wear appropriate glasses. More recently, a digital method of 3D projection has been perfected. In this method, a personal computer is used as the source of the images, which are arranged in a Microsoft PowerPoint presentation. A beam splitter device is used to connect the computer source to 2 digital, portable projectors. Filters, a silver screen, and glasses are used, similar to the classic method. Among other advantages, this method brings flexibility to 3D presentations by allowing the combination of 3D anatomical and surgical still images and videos. It eliminates the need for using film and film developing, lowering the costs of the process. In using small, powerful digital projectors, this method substitutes for the previous technology, without incurring a loss of quality, and enhances portability.
Speckle disturbance limit in laser-based cinema projection systems
Verschaffelt, Guy; Roelandt, Stijn; Meuret, Youri; Van den Broeck, Wendy; Kilpi, Katriina; Lievens, Bram; Jacobs, An; Janssens, Peter; Thienpont, Hugo
2015-01-01
In a multi-disciplinary effort, we investigate the level of speckle that can be tolerated in a laser cinema projector based on a quality of experience experiment with movie clips shown to a test audience in a real-life movie theatre setting. We identify a speckle disturbance threshold by statistically analyzing the observers’ responses for different values of the amount of speckle, which was monitored using a well-defined speckle measurement method. The analysis shows that the speckle perception of a human observer is not only dependent on the objectively measured amount of speckle, but it is also strongly influenced by the image content. The speckle disturbance limit for movies turns out to be substantially larger than that for still images, and hence is easier to attain. PMID:26370531
Speckle disturbance limit in laser-based cinema projection systems.
Verschaffelt, Guy; Roelandt, Stijn; Meuret, Youri; Van den Broeck, Wendy; Kilpi, Katriina; Lievens, Bram; Jacobs, An; Janssens, Peter; Thienpont, Hugo
2015-09-15
In a multi-disciplinary effort, we investigate the level of speckle that can be tolerated in a laser cinema projector based on a quality of experience experiment with movie clips shown to a test audience in a real-life movie theatre setting. We identify a speckle disturbance threshold by statistically analyzing the observers' responses for different values of the amount of speckle, which was monitored using a well-defined speckle measurement method. The analysis shows that the speckle perception of a human observer is not only dependent on the objectively measured amount of speckle, but it is also strongly influenced by the image content. The speckle disturbance limit for movies turns out to be substantially larger than that for still images, and hence is easier to attain.
3D shape measurement of moving object with FFT-based spatial matching
NASA Astrophysics Data System (ADS)
Guo, Qinghua; Ruan, Yuxi; Xi, Jiangtao; Song, Limei; Zhu, Xinjun; Yu, Yanguang; Tong, Jun
2018-03-01
This work presents a new technique for 3D shape measurement of moving object in translational motion, which finds applications in online inspection, quality control, etc. A low-complexity 1D fast Fourier transform (FFT)-based spatial matching approach is devised to obtain accurate object displacement estimates, and it is combined with single shot fringe pattern prolometry (FPP) techniques to achieve high measurement performance with multiple captured images through coherent combining. The proposed technique overcomes some limitations of existing ones. Specifically, the placement of marks on object surface and synchronization between projector and camera are not needed, the velocity of the moving object is not required to be constant, and there is no restriction on the movement trajectory. Both simulation and experimental results demonstrate the effectiveness of the proposed technique.
Speckle disturbance limit in laser-based cinema projection systems
NASA Astrophysics Data System (ADS)
Verschaffelt, Guy; Roelandt, Stijn; Meuret, Youri; van den Broeck, Wendy; Kilpi, Katriina; Lievens, Bram; Jacobs, An; Janssens, Peter; Thienpont, Hugo
2015-09-01
In a multi-disciplinary effort, we investigate the level of speckle that can be tolerated in a laser cinema projector based on a quality of experience experiment with movie clips shown to a test audience in a real-life movie theatre setting. We identify a speckle disturbance threshold by statistically analyzing the observers’ responses for different values of the amount of speckle, which was monitored using a well-defined speckle measurement method. The analysis shows that the speckle perception of a human observer is not only dependent on the objectively measured amount of speckle, but it is also strongly influenced by the image content. The speckle disturbance limit for movies turns out to be substantially larger than that for still images, and hence is easier to attain.
75 FR 6208 - Proposed Collection; Comment Request; Web Based Training for Pain Management Providers
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-08
... Request; Web Based Training for Pain Management Providers SUMMARY: Under the provisions of Section 3507(a... comment. Proposed Collection Title: Web Based Training for Pain Management Providers. Type of Information... effectiveness of the Web Based Training for Pain Management Providers, via the Web site PainAndAddiction...
Jue, J Jane S; Metlay, Joshua P
2011-11-01
Web-based health resources on college websites have the potential to reach a substantial number of college students. The objective of this study was to characterize how colleges use their websites to educate about and promote health. This study was a cross-sectional analysis of websites from a nationally representative sample of 426 US colleges. Reviewers abstracted information about Web-based health resources from college websites, namely health information, Web links to outside health resources, and interactive Web-based health programs. Nearly 60% of US colleges provided health resources on their websites, 49% provided health information, 48% provided links to outside resources, and 28% provided interactive Web-based health programs. The most common topics of Web-based health resources were mental health and general health. We found widespread presence of Web-based health resources available from various delivery modes and covering a range of health topics. Although further research in this new modality is warranted, Web-based health resources hold promise for reaching more US college students.
Apparatus for Teaching Physics.
ERIC Educational Resources Information Center
Gottlieb, Herbert H., Ed.
1980-01-01
Presents two experimental set-ups. The first demonstrates the law of Malus using a pair of Polaroid polarizers and a monochromatic light source with an interference filter. The second describes a modification of Hilton's apparatus to demonstrate the effects of the magnetic hysteresis on an overhead projector. (CS)
One corner of the third floor has examples of Edison ...
One corner of the third floor has examples of Edison motion picture projectors in rather poor condition. Better preserved examples are in storage in Vault #12. - Thomas A. Edison Laboratories, Building No. 5, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
ERIC Educational Resources Information Center
Miller, Franklin, Jr.
1971-01-01
The history of the short film and the single concept film loop is presented. Lists fourteen reasons why it may be necessary to make and use a film loop. Film loop projectors are analyzed according to present features and deficiencies with predictions on future improvements. (DS)
A Generalized Method of Image Analysis from an Intercorrelation Matrix which May Be Singular.
ERIC Educational Resources Information Center
Yanai, Haruo; Mukherjee, Bishwa Nath
1987-01-01
This generalized image analysis method is applicable to singular and non-singular correlation matrices (CMs). Using the orthogonal projector and a weaker generalized inverse matrix, image and anti-image covariance matrices can be derived from a singular CM. (SLD)
ERIC Educational Resources Information Center
Basso, Robert
1998-01-01
Presents a lesson plan that enabled students to create their own portraits in the style of Pablo Picasso; students utilized their initial collages/drawings, enlarging them with an overhead projector, to paint their final products using oil pastels. Indicates the students also learned about the different "periods" of Picasso's artistic…
ERIC Educational Resources Information Center
Villano, Matt
2009-01-01
From wireless connectivity to light processing improvements, digital projectors have incorporated a number of technological advancements in recent years--developments that have made the tools even easier for higher education technologists to use. This article offers some vendor insights about some of those trends, and the ways in which they might…
NASA Astrophysics Data System (ADS)
Kamagara, Abel; Wang, Xiangzhao; Li, Sikun
2018-03-01
We propose a method to compensate for the projector intensity nonlinearity induced by gamma effect in three-dimensional (3-D) fringe projection metrology by extending high-order spectra analysis and bispectral norm minimization to digital sinusoidal fringe pattern analysis. The bispectrum estimate allows extraction of vital signal information features such as spectral component correlation relationships in fringe pattern images. Our approach exploits the fact that gamma introduces high-order harmonic correlations in the affected fringe pattern image. Estimation and compensation of projector nonlinearity is realized by detecting and minimizing the normed bispectral coherence of these correlations. The proposed technique does not require calibration information and technical knowledge or specification of fringe projection unit. This is promising for developing a modular and calibration-invariant model for intensity nonlinear gamma compensation in digital fringe pattern projection profilometry. Experimental and numerical simulation results demonstrate this method to be efficient and effective in improving the phase measuring accuracies with phase-shifting fringe pattern projection profilometry.
3D Rainbow Particle Tracking Velocimetry
NASA Astrophysics Data System (ADS)
Aguirre-Pablo, Andres A.; Xiong, Jinhui; Idoughi, Ramzi; Aljedaani, Abdulrahman B.; Dun, Xiong; Fu, Qiang; Thoroddsen, Sigurdur T.; Heidrich, Wolfgang
2017-11-01
A single color camera is used to reconstruct a 3D-3C velocity flow field. The camera is used to record the 2D (X,Y) position and colored scattered light intensity (Z) from white polyethylene tracer particles in a flow. The main advantage of using a color camera is the capability of combining different intensity levels for each color channel to obtain more depth levels. The illumination system consists of an LCD projector placed perpendicularly to the camera. Different intensity colored level gradients are projected onto the particles to encode the depth position (Z) information of each particle, benefiting from the possibility of varying the color profiles and projected frequencies up to 60 Hz. Chromatic aberrations and distortions are estimated and corrected using a 3D laser engraved calibration target. The camera-projector system characterization is presented considering size and depth position of the particles. The use of these components reduces dramatically the cost and complexity of traditional 3D-PTV systems.
Speckle reduction using deformable mirrors with diffusers in a laser pico-projector.
Chen, Hsuan-An; Pan, Jui-Wen; Yang, Zu-Po
2017-07-24
We propose a design for speckle reduction in a laser pico-projector adopting diffusers and deformable mirrors. This research focuses on speckle noise suppression by changing the angle of divergence of the diffuser. Moreover, the speckle contrast value can be further reduced by the addition of a deformable mirror. The speckle reduction ability obtained using diffusers with different divergence angles is compared. Three types of diffuser designs are compared in the experiments. For Type 1 which uses a circular symmetric diffuser the speckle contrast value can be decreased to 0.0264. For Type 2, the speckle contrast value can be reduced to 0.0267 because of the inclusion of an elliptical distribution diffuser. With Type 3 which includes a combination of the circular distribution diffuser and elliptical distribution diffuser, the speckle contrast value can be reduced to 0.0236. For all three types, the speckle contrast value is lower than 0.05. Under this speckle value, the speckle phenomenon is invisible to the human eye.
Phase-stepped fringe projection by rotation about the camera's perspective center.
Huddart, Y R; Valera, J D; Weston, N J; Featherstone, T C; Moore, A J
2011-09-12
A technique to produce phase steps in a fringe projection system for shape measurement is presented. Phase steps are produced by introducing relative rotation between the object and the fringe projection probe (comprising a projector and camera) about the camera's perspective center. Relative motion of the object in the camera image can be compensated, because it is independent of the distance of the object from the camera, whilst the phase of the projected fringes is stepped due to the motion of the projector with respect to the object. The technique was validated with a static fringe projection system by moving an object on a coordinate measuring machine (CMM). The alternative approach, of rotating a lightweight and robust CMM-mounted fringe projection probe, is discussed. An experimental accuracy of approximately 1.5% of the projected fringe pitch was achieved, limited by the standard phase-stepping algorithms used rather than by the accuracy of the phase steps produced by the new technique.
NASA Astrophysics Data System (ADS)
Buzzicotti, M.; Linkmann, M.; Aluie, H.; Biferale, L.; Brasseur, J.; Meneveau, C.
2018-02-01
The effects of different filtering strategies on the statistical properties of the resolved-to-subfilter scale (SFS) energy transfer are analysed in forced homogeneous and isotropic turbulence. We carry out a-priori analyses of the statistical characteristics of SFS energy transfer by filtering data obtained from direct numerical simulations with up to 20483 grid points as a function of the filter cutoff scale. In order to quantify the dependence of extreme events and anomalous scaling on the filter, we compare a sharp Fourier Galerkin projector, a Gaussian filter and a novel class of Galerkin projectors with non-sharp spectral filter profiles. Of interest is the importance of Galilean invariance and we confirm that local SFS energy transfer displays intermittency scaling in both skewness and flatness as a function of the cutoff scale. Furthermore, we quantify the robustness of scaling as a function of the filtering type.
Structural instability in polyacene: A projector quantum Monte Carlo study
NASA Astrophysics Data System (ADS)
Srinivasan, Bhargavi; Ramasesha, S.
1998-04-01
We have studied polyacene within the Hubbard model to explore the effect of electron correlations on the Peierls' instability in a system marginally away from one dimension. We employ the projector quantum Monte Carlo method to obtain ground-state estimates of the energy and various correlation functions. We find strong similarities between polyacene and polyacetylene which can be rationalized from the real-space valence-bond arguments of Mazumdar and Dixit. Electron correlations tend to enhance the Peierls' instability in polyacene. This enhancement appears to attain a maximum at U/t~3.0, and the maximum shifts to larger values when the alternation parameter is increased. The system shows no tendency to destroy the imposed bond-alternation pattern, as evidenced by the bond-bond correlations. The cis distortion is seen to be favored over the trans distortion. The spin-spin correlations show that undistorted polyacene is susceptible to a spin-density-wave distortion for large interaction strength. The charge-charge correlations indicate the absence of a charge-density-wave distortion for the parameters studied.
Distributed rendering for multiview parallax displays
NASA Astrophysics Data System (ADS)
Annen, T.; Matusik, W.; Pfister, H.; Seidel, H.-P.; Zwicker, M.
2006-02-01
3D display technology holds great promise for the future of television, virtual reality, entertainment, and visualization. Multiview parallax displays deliver stereoscopic views without glasses to arbitrary positions within the viewing zone. These systems must include a high-performance and scalable 3D rendering subsystem in order to generate multiple views at real-time frame rates. This paper describes a distributed rendering system for large-scale multiview parallax displays built with a network of PCs, commodity graphics accelerators, multiple projectors, and multiview screens. The main challenge is to render various perspective views of the scene and assign rendering tasks effectively. In this paper we investigate two different approaches: Optical multiplexing for lenticular screens and software multiplexing for parallax-barrier displays. We describe the construction of large-scale multi-projector 3D display systems using lenticular and parallax-barrier technology. We have developed different distributed rendering algorithms using the Chromium stream-processing framework and evaluate the trade-offs and performance bottlenecks. Our results show that Chromium is well suited for interactive rendering on multiview parallax displays.
Development of a high-definition IR LED scene projector
NASA Astrophysics Data System (ADS)
Norton, Dennis T.; LaVeigne, Joe; Franks, Greg; McHugh, Steve; Vengel, Tony; Oleson, Jim; MacDougal, Michael; Westerfeld, David
2016-05-01
Next-generation Infrared Focal Plane Arrays (IRFPAs) are demonstrating ever increasing frame rates, dynamic range, and format size, while moving to smaller pitch arrays.1 These improvements in IRFPA performance and array format have challenged the IRFPA test community to accurately and reliably test them in a Hardware-In-the-Loop environment utilizing Infrared Scene Projector (IRSP) systems. The rapidly-evolving IR seeker and sensor technology has, in some cases, surpassed the capabilities of existing IRSP technology. To meet the demands of future IRFPA testing, Santa Barbara Infrared Inc. is developing an Infrared Light Emitting Diode IRSP system. Design goals of the system include a peak radiance >2.0W/cm2/sr within the 3.0-5.0μm waveband, maximum frame rates >240Hz, and >4million pixels within a form factor supported by pixel pitches <=32μm. This paper provides an overview of our current phase of development, system design considerations, and future development work.
NASA Astrophysics Data System (ADS)
Giacomini, l.; Aloisi, F.; De Angelis, I.
2017-09-01
Teaching planetary science using a spherical projector to show the planets' surfaces is a very effective but usually very expensive idea. Whatsmore, it usually assumes the availability of a dedicated space and a trained user. "Planets in a room" is a prototypal low cost version of a small, spherical projector that teachers, museum, planetary scientists and other individuals can easily build and use on their own, to show and teach the planets The project of "Planets in a Room" was made by the italian non-profit association Speak Science with the collaboration of INAF-IAPS of Rome and the Roma Tre University (Dipartimento di Matematica e Fisica). This proposal was funded by the Europlanet Outreach Funding Scheme in 2016. "Planets in a room" will be presented during EPSC 2017 to give birth to the second phase of the project, when the outreach and research community will be involved and schools from all over Europe will be invited to participate with the aim of bringing planetary science to a larger audience.
The use of the liquid crystal display (LCD) panel as a teaching aid in medical lectures.
Wong, K T
1992-01-01
The liquid crystal display (LCD) panel is designed to project on-screen information of a microcomputer onto a larger screen with the aid of a standard overhead projector, so that large audiences may view on-screen information without having to crowd around the TV monitor. As little has been written about its use as a visual aid in medical teaching, the present report documents its use in a series of pathology lectures delivered, over a 2-year period, to two classes of about 150 medical students each. Some advantages of the LCD panel over the 35mm slide include the flexibility of last-minute text changes and less lead time needed for text preparation. It eliminates the problems of messy last-minute changes in, and improves legibility of, handwritten overhead projector transparencies. The disadvantages of using an LCD panel include the relatively bulky equipment which may pose transport problems, image clarity that is inferior to the 35mm slide, and equipment costs.
Dai, Meiling; Yang, Fujun; He, Xiaoyuan
2012-04-20
A simple but effective fringe projection profilometry is proposed to measure 3D shape by using one snapshot color sinusoidal fringe pattern. One color fringe pattern encoded with a sinusoidal fringe (as red component) and one uniform intensity pattern (as blue component) is projected by a digital video projector, and the deformed fringe pattern is recorded by a color CCD camera. The captured color fringe pattern is separated into its RGB components and division operation is applied to red and blue channels to reduce the variable reflection intensity. Shape information of the tested object is decoded by applying an arcsine algorithm on the normalized fringe pattern with subpixel resolution. In the case of fringe discontinuities caused by height steps, or spatially isolated surfaces, the separated blue component is binarized and used for correcting the phase demodulation. A simple and robust method is also introduced to compensate for nonlinear intensity response of the digital video projector. The experimental results demonstrate the validity of the proposed method.
ERIC Educational Resources Information Center
Hall, Richard., Ed.
This proceedings of the Sixth International Conference on Web-Based Learning, NAWeb 2000, includes the following papers: "Is a Paradigm Shift Required To Effectively Teach Web-Based Instruction?"; "Issues in Courseware Reuse for a Web-Based Information System"; "The Digital Curriculum Database: Meeting the Needs of Industry and the Challenge of…
High spatial resolution with zoomable saw-tooth refractive lenses?
NASA Astrophysics Data System (ADS)
Jark, Werner
2011-09-01
Refractive x-ray lenses can be assembled from two opposing saw-tooth structures, when they are inclined with respect to each other and almost touch at one end. An incident plane wave will then traverse a varying number of triangular prisms, which direct the beam towards the optical axis and focus it. Optically speaking the plane wave traverses a parabolic lens profile, which is approximated by trapezoidal segments. The parabolic profile will focus ideally, when a lens can be discussed in the "thin lens" approximation. Now the saw-tooth refractive lens is found to be too "thick". The residual aberrations limit the focusing capability to just submicrometer focusing, significantly above the limit in diffraction limited focusing. It is shown that the aberrations can be removed by introducing a variation into the originally constant saw-tooth angle. After this modification the lens can be operated in the diffraction limited regime. Spot sizes even below 0.1 micrometer are then feasible. This performance in terms of spatial resolution is found to be limited to focusing to microspots and is not available, when the saw-tooth refractive lens is used in an imaging setup. In this case the spatial resolution deteriorates rapidly with increasing off axis distance of the object to be imaged.
Practical guidelines for development of web-based interventions.
Chee, Wonshik; Lee, Yaelim; Chee, Eunice; Im, Eun-Ok
2014-10-01
Despite a recent high funding priority on technological aspects of research and a high potential impact of Web-based interventions on health, few guidelines for the development of Web-based interventions are currently available. In this article, we propose practical guidelines for development of Web-based interventions based on an empirical study and an integrative literature review. The empirical study aimed at development of a Web-based physical activity promotion program that was specifically tailored to Korean American midlife women. The literature review included a total of 202 articles that were retrieved through multiple databases. On the basis of the findings of the study and the literature review, we propose directions for development of Web-based interventions in the following steps: (1) meaningfulness and effectiveness, (2) target population, (3) theoretical basis/program theory, (4) focus and objectives, (5) components, (6) technological aspects, and (7) logistics for users. The guidelines could help promote further development of Web-based interventions at this early stage of Web-based interventions in nursing.
Web-Based Testing: Exploring the Relationship between Hardware Usability and Test Performance
ERIC Educational Resources Information Center
Huff, Kyle; Cline, Melinda; Guynes, Carl S.
2012-01-01
Web-based testing has recently become common in both academic and professional settings. A web-based test is administered through a web browser. Individuals may complete a web-based test at nearly any time and at any place. In addition, almost any computer lab can become a testing center. It is important to understand the environmental issues that…
Enable Web-Based Tracking and Guiding by Integrating Location-Awareness with the World Wide Web
ERIC Educational Resources Information Center
Zhou, Rui
2008-01-01
Purpose: The aim of this research is to enable web-based tracking and guiding by integrating location-awareness with the Worldwide Web so that the users can use various location-based applications without installing extra software. Design/methodology/approach: The concept of web-based tracking and guiding is introduced and the relevant issues are…
Apparatus for Teaching Physics.
ERIC Educational Resources Information Center
Gottlieb, Herbert H., Ed.
1978-01-01
Describes a few apparatuses and demonstrations for teaching physics under the headings: demonstrating resonance of the inner ear, constructing a potential well-hill for overhead projectors, rubber tube vacuum pump, improvement on the simple homemade motor, air track to demonstrate sailing into the wind, and center of gravity and stability. (GA)
Learning Factory--Integrative E-Learning
ERIC Educational Resources Information Center
Steininger, Peter
2017-01-01
Integrative E-Learning (IEP): The goal of the project is the development and testing of an integrative teaching format for the assembly of imported, tried and tested (classic) teaching elements (e.g. wallboard and flipchart, screen walls and other visualization aids, Projector, manuscripts, and workbooks, etc.), with contemporary, innovative…
ERIC Educational Resources Information Center
Martínez-Alemán, Ana M.
2014-01-01
Technology's march into the college classroom continues. Generations of college and university faculty have both embraced and resisted instructional technologies such as the book, the mimeograph, the overhead projector, and hand-held calculators. Now college and university faculty are greeting the 21st century's signature…
Demonstrations of Some Optical Properties of Liquid Crystals.
ERIC Educational Resources Information Center
Nicastro, Anthony J.
1983-01-01
Discusses several properties of liquid crystal displays. Includes instructions for demonstrating liquid crystalline phase, ordering of the long axes of molecules along one direction, and electro-optic effects. The latter is accomplished with the use of an overhead projector following preparation of a sandwich cell. (JN)
School Libraries: A Design Recipe for the Future.
ERIC Educational Resources Information Center
Myerberg, Henry
2002-01-01
Discusses design elements of a 21st century school library, including space, books and shelving, seats, tables, technology (computers, scanners, projectors), building materials (wood, metal, plastic, paint, glass, fibers), and light and color. A sidebar describes the L!BRARY initiative to creatively design, professionally staff, and…
The Classroom as Global Media Center
ERIC Educational Resources Information Center
Nair, Prakash
2007-01-01
This article looks at ways in which schools buildings designed for today and tomorrow can provide superior environments for learning by keeping pace with rapidly evolving technologies that have redefined the educational landscape. Wireless classrooms, data projectors and wall-mounted plasma monitors are cited as in-classroom technologies of…
Exploratorium: Exploring Water.
ERIC Educational Resources Information Center
Brand, Judith, Ed.
2001-01-01
This issue of Exploratorium focuses on water and its varied uses in our environment. Articles include: (1) "Adventures with Water" (Eric Muller); (2) "Water: The Liquid of Life" (Karen E. Kalumuck); (3) "Water-Drop Projector" (Gorazd Planinsic); (4) "Waterways and Means" (Pearl Tesler); (5) "Explore Natural Phenomena in the Museum--and Just…
Advances in Projection Technology for On-Line Instruction.
ERIC Educational Resources Information Center
Davis, H. Scott; Miller, Marsha
This document consists of supplemental information designed to accompany a presentation on the application of projection technology, including video projectors and liquid crystal display (LCD) devices, in the online catalog library instruction program at the Indiana State University libraries. Following an introductory letter, the packet includes:…
ERIC Educational Resources Information Center
Schaffhauser, Dian
2010-01-01
Institutions already cater to the technology needs of students. According to the 2008 Campus Computing survey, 60 percent of colleges and universities offer pervasive or near-pervasive wireless; computers are as ubiquitous as water bottles; course management systems have become one-stop shops for class content; few classrooms lack projectors; and…
ERIC Educational Resources Information Center
Tang, Thomas Li-Ping; Austin, M. Jill
2009-01-01
This study examined business students' perceptions of four objectives (i.e., Enjoyment, Learning, Motivation, and Career Application) across five teaching technologies (i.e., Projector, PowerPoint, Video, the Internet, and Lecture), business professors' effective application of technologies, and students' academic performance. We collected data…
77 FR 75617 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-21
... transmittal, policy justification, and Sensitivity of Technology. Dated: December 18, 2012. Aaron Siegel... Processor Cabinets, 2 Video Wall Screen and Projector Systems, 46 Flat Panel Displays, and 2 Distributed Video Systems), 2 ship sets AN/SPQ-15 Digital Video Distribution Systems, 2 ship sets Operational...
Fourier rebinning and consistency equations for time-of-flight PET planograms
Li, Yusheng; Defrise, Michel; Matej, Samuel; Metzler, Scott D
2016-01-01
Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John's equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations and the Fourier-John equation, which are the duals of the consistency equations and John's equation, respectively. We then solve the Fourier consistency equations and Fourier-John equation using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms. Finally, we give numerical examples of implementation of a fast 2D TOF planogram projector and Fourier-based rebinning for a 2D TOF planograms using the FORCEs to show the efficacy of the Fourier-based solutions. PMID:28255191
Fourier rebinning and consistency equations for time-of-flight PET planograms.
Li, Yusheng; Defrise, Michel; Matej, Samuel; Metzler, Scott D
2016-01-01
Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John's equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations and the Fourier-John equation, which are the duals of the consistency equations and John's equation, respectively. We then solve the Fourier consistency equations and Fourier-John equation using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms. Finally, we give numerical examples of implementation of a fast 2D TOF planogram projector and Fourier-based rebinning for a 2D TOF planograms using the FORCEs to show the efficacy of the Fourier-based solutions.
NASA Astrophysics Data System (ADS)
Servin, Manuel; Padilla, Moises; Garnica, Guillermo; Gonzalez, Adonai
2016-12-01
In this work we review and combine two techniques that have been recently published for three-dimensional (3D) fringe projection profilometry and phase unwrapping, namely: co-phased profilometry and 2-steps temporal phase-unwrapping. By combining these two methods we get a more accurate, higher signal-to-noise 3D profilometer for discontinuous industrial objects. In single-camera single-projector (standard) profilometry, the camera and the projector must form an angle between them. The phase-sensitivity of the profilometer depends on this angle, so it cannot be avoided. This angle produces regions with self-occluding shadows and glare from the solid as viewed from the camera's perspective, making impossible the demodulation of the fringe-pattern there. In other words, the phase data is undefined at those shadow regions. As published recently, this limitation can be solved by using several co-phased fringe-projectors and a single camera. These co-phased projectors are positioned at different directions towards the object, and as a consequence most shadows are compensated. In addition to this, most industrial objects are highly discontinuous, which precludes the use of spatial phase-unwrappers. One way to avoid spatial unwrapping is to decrease the phase-sensitivity to a point where the demodulated phase is bounded to one lambda, so the need for phase-unwrapping disappears. By doing this, however, the recovered non-wrapped phase contains too much harmonic distortion and noise. Using our recently proposed two-step temporal phase-unwrapping technique, the high-sensitivity phase is unwrapped using the low-frequency one as initial gross estimation. This two-step unwrapping technique solves the 3D object discontinuities while keeping the accuracy of the high-frequency profilometry data. In scientific research, new art are derived as logical and consistent result of previous efforts in the same direction. Here we present a new 3D-profilometer combining these two recently published methods: co-phased profilometry and two-steps temporal phase-unwrapping. By doing this, we obtain a new and more powerful 3D profilometry technique which overcomes the two main limitations of previous fringe-projection profilometers namely: high phase-sensitivity digitalization of discontinuous objects and solid's self-generated shadow minimization. This new 3D profilometer is demonstrated by an experiment digitizing a discontinuous 3D industrial-solid where the advantages of this new profilometer with respect to previous art are clearly shown.
Fringe image processing based on structured light series
NASA Astrophysics Data System (ADS)
Gai, Shaoyan; Da, Feipeng; Li, Hongyan
2009-11-01
The code analysis of the fringe image is playing a vital role in the data acquisition of structured light systems, which affects precision, computational speed and reliability of the measurement processing. According to the self-normalizing characteristic, a fringe image processing method based on structured light is proposed. In this method, a series of projective patterns is used when detecting the fringe order of the image pixels. The structured light system geometry is presented, which consist of a white light projector and a digital camera, the former projects sinusoidal fringe patterns upon the object, and the latter acquires the fringe patterns that are deformed by the object's shape. Then the binary images with distinct white and black strips can be obtained and the ability to resist image noise is improved greatly. The proposed method can be implemented easily and applied for profile measurement based on special binary code in a wide field.
Meeting the challenges of developing LED-based projection displays
NASA Astrophysics Data System (ADS)
Geißler, Enrico
2006-04-01
The main challenge in developing a LED-based projection system is to meet the brightness requirements of the market. Therefore a balanced combination of optical, electrical and thermal parameters must be reached to achieve these performance and cost targets. This paper describes the system design methodology for a digital micromirror display (DMD) based optical engine using LEDs as the light source, starting at the basic physical and geometrical parameters of the DMD and other optical elements through characterization of the LEDs to optimizing the system performance by determining optimal driving conditions. LEDs have a luminous flux density which is just at the threshold of acceptance in projection systems and thus only a fully optimized optical system with a matched set of LEDs can be used. This work resulted in two projection engines, one for a compact pocket projector and the other for a rear projection television, both of which are currently in commercialization.
NVIDIA OptiX ray-tracing engine as a new tool for modelling medical imaging systems
NASA Astrophysics Data System (ADS)
Pietrzak, Jakub; Kacperski, Krzysztof; Cieślar, Marek
2015-03-01
The most accurate technique to model the X- and gamma radiation path through a numerically defined object is the Monte Carlo simulation which follows single photons according to their interaction probabilities. A simplified and much faster approach, which just integrates total interaction probabilities along selected paths, is known as ray tracing. Both techniques are used in medical imaging for simulating real imaging systems and as projectors required in iterative tomographic reconstruction algorithms. These approaches are ready for massive parallel implementation e.g. on Graphics Processing Units (GPU), which can greatly accelerate the computation time at a relatively low cost. In this paper we describe the application of the NVIDIA OptiX ray-tracing engine, popular in professional graphics and rendering applications, as a new powerful tool for X- and gamma ray-tracing in medical imaging. It allows the implementation of a variety of physical interactions of rays with pixel-, mesh- or nurbs-based objects, and recording any required quantities, like path integrals, interaction sites, deposited energies, and others. Using the OptiX engine we have implemented a code for rapid Monte Carlo simulations of Single Photon Emission Computed Tomography (SPECT) imaging, as well as the ray-tracing projector, which can be used in reconstruction algorithms. The engine generates efficient, scalable and optimized GPU code, ready to run on multi GPU heterogeneous systems. We have compared the results our simulations with the GATE package. With the OptiX engine the computation time of a Monte Carlo simulation can be reduced from days to minutes.
Electrostatic artificial eyelid actuator as an analog micromirror device
NASA Astrophysics Data System (ADS)
Goodwin, Scott H.; Dausch, David E.; Solomon, Steven L.; Lamvik, Michael K.
2005-05-01
An electrostatic MEMS actuator is described for use as an analog micromirror device (AMD) for high performance, broadband, hardware-in-the-loop (HWIL) scene generation. Current state-of-the-art technology is based on resistively heated pixel arrays. As these arrays drive to the higher scene temperatures required by missile defense scenarios, the power required to drive the large format resistive arrays will ultimately become prohibitive. Existing digital micromirrors (DMD) are, in principle, capable of generating the required scene irradiances, but suffer from limited dynamic range, resolution and flicker effects. An AMD would be free of these limitations, and so represents a viable alternative for high performance UV/VIS/IR scene generation. An electrostatic flexible film actuator technology, developed for use as "artificial eyelid" shutters for focal plane sensors to protect against damaging radiation, is suitable as an AMD for analog control of projection irradiance. In shutter applications, the artificial eyelid actuator contained radius of curvature as low as 25um and operated at high voltage (>200V). Recent testing suggests that these devices are capable of analog operation as reflective microcantilever mirrors appropriate for scene projector systems. In this case, the device would possess larger radius and operate at lower voltages (20-50V). Additionally, frame rates have been measured at greater than 5kHz for continuous operation. The paper will describe the artificial eyelid technology, preliminary measurements of analog test pixels, and design aspects related to application for scene projection systems. We believe this technology will enable AMD projectors with at least 5122 spatial resolution, non-temporally-modulated output, and pixel response times of <1.25ms.
Hybrid-mode read-in integrated circuit for infrared scene projectors
NASA Astrophysics Data System (ADS)
Cho, Min Ji; Shin, Uisub; Lee, Hee Chul
2017-05-01
The infrared scene projector (IRSP) is a tool for evaluating infrared sensors by producing infrared images. Because sensor testing with IRSPs is safer than field testing, the usefulness of IRSPs is widely recognized at present. The important performance characteristics of IRSPs are the thermal resolution and the thermal dynamic range. However, due to an existing trade-off between these requirements, it is often difficult to find a workable balance between them. The conventional read-in integrated circuit (RIIC) can be classified into two types: voltage-mode and current-mode types. An IR emitter driven by a voltage-mode RIIC offers a fine thermal resolution. On the other hand, an emitter driven by the current-mode RIIC has the advantage of a wide thermal dynamic range. In order to provide various scenes, i.e., from highresolution scenes to high-temperature scenes, both of the aforementioned advantages are required. In this paper, a hybridmode RIIC which is selectively operated in two modes is proposed. The mode-selective characteristic of the proposed RIIC allows users to generate high-fidelity scenes regardless of the scene content. A prototype of the hybrid-mode RIIC was fabricated using a 0.18-μm 1-poly 6-metal CMOS process. The thermal range and the thermal resolution of the IR emitter driven by the proposed circuit were calculated based on measured data. The estimated thermal dynamic range of the current mode was from 261K to 790K, and the estimated thermal resolution of the voltage mode at 300K was 23 mK with a 12-bit gray-scale resolution.
Can grapheme-color synesthesia be induced by hypnosis?
Anderson, Hazel P.; Seth, Anil K.; Dienes, Zoltan; Ward, Jamie
2014-01-01
Grapheme-color synesthesia is a perceptual experience where graphemes, letters or words evoke a specific color, which are experienced either as spatially coincident with the grapheme inducer (projector sub-type) or elsewhere, perhaps without a definite spatial location (associator sub-type). Here, we address the question of whether synesthesia can be rapidly produced using a hypnotic color suggestion to examine the possibility of “hypnotic synesthesia”, i.e., subjectively experienced color hallucinations similar to those experienced by projector synesthetes. We assess the efficacy of this intervention using an “embedded figures” test, in which participants are required to detect a shape (e.g., a square) composed of local graphemic elements. For grapheme-color synesthetes, better performance on the task has been linked to a higher proportion of graphemes perceived as colored. We found no performance benefits on this test when using a hypnotic suggestion, as compared to a no-suggestion control condition. The same result was found when participants were separated according to the degree to which they were susceptible to the suggestion (number of colored trials perceived). However, we found a relationship between accuracy and subjective reports of color in those participants who reported a large proportion of colored trials: trials in which the embedded figure was accurately recognized (relative to trials in which it was not) were associated with reports of more intense colors occupying a greater spatial extent. Collectively, this implies that hypnotic color was only perceived after shape detection rather than aiding in shape detection via color-based perceptual grouping. The results suggest that hypnotically induced colors are not directly comparable to synesthetic ones. PMID:24829555
Online Learning: A Comparison of Web-Based and Land-Based Courses
ERIC Educational Resources Information Center
Brown, Joy L. M.
2012-01-01
Distance learning has become more popular in recent years. Due to concern about the quality of web-based courses, the purpose of this study was to explore the differences in web-based versus land-based courses. In this study, the researcher compares web-based and land-based education courses to explore the strengths and weaknesses of each type of…
ERIC Educational Resources Information Center
Loh, Christian Sebastian
2001-01-01
Examines how mobile computers, or personal digital assistants (PDAs), can be used in a Web-based learning environment. Topics include wireless networks on college campuses; online learning; Web-based learning technologies; synchronous and asynchronous communication via the Web; content resources; Web connections; and collaborative learning. (LRW)
Concept Mapping Your Web Searches: A Design Rationale and Web-Enabled Application
ERIC Educational Resources Information Center
Lee, Y.-J.
2004-01-01
Although it has become very common to use World Wide Web-based information in many educational settings, there has been little research on how to better search and organize Web-based information. This paper discusses the shortcomings of Web search engines and Web browsers as learning environments and describes an alternative Web search environment…
Nakata, Satoshi; Morishima, Sayaka; Ichino, Takatoshi; Kitahata, Hiroyuki
2006-12-21
The photosensitive Belousov-Zhabotinsky (BZ) reaction was investigated on a circular ring, which was drawn using computer software and then projected on a film soaked with BZ solution using a liquid-crystal projector. Under the initial conditions, a chemical wave propagated with a constant velocity on the black ring under a bright background. When the background was rapidly changed to dark, coexistence of the oscillation on part of the ring and propagation of the chemical wave on the other part was observed. These experimental results are discussed in relation to the nature of the photosensitive BZ reaction and theoretically reproduced based on a reaction-diffusion system using the modified Oregonator model.
Color speckle in laser displays
NASA Astrophysics Data System (ADS)
Kuroda, Kazuo
2015-07-01
At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).
Pindelska, Edyta; Szeleszczuk, Lukasz; Pisklak, Dariusz Maciej; Mazurek, Andrzej; Kolodziejski, Waclaw
2015-01-01
Clopidogrel hydrogensulfate (HSCL) is an antiplatelet agent, one of top-selling drugs in the world. In this paper, we have described a rapid and convenient method of verification which polymorph of HSCL is present in its final solid dosage form. Our methodology based on solid-state NMR spectroscopy and ab initio gauge-including projector-augmented wave calculations of NMR shielding constants is appropriate for currently available commercial solid dosage forms of HSCL. Furthermore, such structural characterization can assist with the development of new pharmaceutical products containing HSCL and also be useful in the identification of counterfeit drugs. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Nanophotonic projection system.
Aflatouni, Firooz; Abiri, Behrooz; Rekhi, Angad; Hajimiri, Ali
2015-08-10
Low-power integrated projection technology can play a key role in development of low-cost mobile devices with built-in high-resolution projectors. Low-cost 3D imaging and holography systems are also among applications of such a technology. In this paper, an integrated projection system based on a two-dimensional optical phased array with fast beam steering capability is reported. Forward biased p-i-n phase modulators with 200MHz bandwidth are used per each array element for rapid phase control. An optimization algorithm is implemented to compensate for the phase dependent attenuation of the p-i-n modulators. Using rapid vector scanning technique, images were formed and recorded within a single snapshot of the IR camera.
A Risk-Analysis Approach to Implementing Web-Based Assessment
ERIC Educational Resources Information Center
Ricketts, Chris; Zakrzewski, Stan
2005-01-01
Computer-Based Assessment is a risky business. This paper proposes the use of a model for web-based assessment systems that identifies pedagogic, operational, technical (non web-based), web-based and financial risks. The strategies and procedures for risk elimination or reduction arise from risk analysis and management and are the means by which…
The internet as psychological laboratory.
Skitka, Linda J; Sargis, Edward G
2006-01-01
This chapter reviews studies published in American Psychological Association (APA) journals from 2003-2004 and additional studies (received in response to listserv requests) that used the Internet to collect data (N=121 total studies). Specific examples of three kinds of Web-based research are reviewed: (a) translational (established methods and research questions are adapted to the Web), (b) phenomenological (behavior on the Web is the focus of study), and (c) novel (methodologically innovations unique to Web-based research). Among other findings, our review indicated that 21% of APA journals published at least one article that reported on Web-based research, most Web-based psychological research uses experimental methods, a surprising number use college student samples, and deception in Web-based research is not uncommon. Strengths and weaknesses of Web-based psychological research in general, and our sample of studies in particular, are reviewed with special attention to possible concerns about sampling and the use of deception.
Web-Based Training Methods for Behavioral Health Providers: A Systematic Review.
Jackson, Carrie B; Quetsch, Lauren B; Brabson, Laurel A; Herschell, Amy D
2018-07-01
There has been an increase in the use of web-based training methods to train behavioral health providers in evidence-based practices. This systematic review focuses solely on the efficacy of web-based training methods for training behavioral health providers. A literature search yielded 45 articles meeting inclusion criteria. Results indicated that the serial instruction training method was the most commonly studied web-based training method. While the current review has several notable limitations, findings indicate that participating in a web-based training may result in greater post-training knowledge and skill, in comparison to baseline scores. Implications and recommendations for future research on web-based training methods are discussed.
75 FR 15693 - Extension of Web-Based TRICARE Assistance Program Demonstration Project
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
... DEPARTMENT OF DEFENSE Office of the Secretary Extension of Web-Based TRICARE Assistance Program Demonstration Project AGENCY: Department of Defense (DoD). ACTION: Notice of a Web-Based TRICARE Assistance... States Code, Section 1092, entitled Web-Based TRICARE Assistance Program. This demonstration was...
Quality evaluation on an e-learning system in continuing professional education of nurses.
Lin, I-Chun; Chien, Yu-Mei; Chang, I-Chiu
2006-01-01
Maintaining high quality in Web-based learning is a powerful means of increasing the overall efficiency and effectiveness of distance learning. Many studies have evaluated Web-based learning but seldom evaluate from the information systems (IS) perspective. This study applied the famous IS Success model in measuring the quality of a Web-based learning system using a Web-based questionnaire for data collection. One hundred and fifty four nurses participated in the survey. Based on confirmatory factor analysis, the variables of the research model fit for measuring the quality of a Web-based learning system. As Web-based education continues to grow worldwide, the results of this study may assist the system adopter (hospital executives), the learner (nurses), and the system designers in making reasonable and informed judgments with regard to the quality of Web-based learning system in continuing professional education.
Randomized, Controlled Trial of CBT Training for PTSD Providers
2016-10-29
trial and comparative effectiveness study is to design, implement and evaluate a cost effective, web based self paced training program to provide skills...without web -centered supervision, may provide an effective means to train increasing numbers of mental health providers in relevant, evidence-based...in equal numbers to three parallel intervention condition: a) Web -based training plus web -centered supervision; b) Web - based training alone; and c
Randomized, Controlled Trial of CBT Training for PTSD Providers
2016-10-01
implement and evaluate a cost effective, web based self-paced training program to provide skills-oriented continuing education for mental health...professionals. The objective is to learn whether novel, internet-based training methods, with or without web -centered supervision, may provide an...condition: a) Web -based training plus web -centered supervision; b) Web - based training alone; and c) Training-as-usual control group. An equal number of
Bringing Control System User Interfaces to the Web
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xihui; Kasemir, Kay
With the evolution of web based technologies, especially HTML5 [1], it becomes possible to create web-based control system user interfaces (UI) that are cross-browser and cross-device compatible. This article describes two technologies that facilitate this goal. The first one is the WebOPI [2], which can seamlessly display CSS BOY [3] Operator Interfaces (OPI) in web browsers without modification to the original OPI file. The WebOPI leverages the powerful graphical editing capabilities of BOY and provides the convenience of re-using existing OPI files. On the other hand, it uses generic JavaScript and a generic communication mechanism between the web browser andmore » web server. It is not optimized for a control system, which results in unnecessary network traffic and resource usage. Our second technology is the WebSocket-based Process Data Access (WebPDA) [4]. It is a protocol that provides efficient control system data communication using WebSocket [5], so that users can create web-based control system UIs using standard web page technologies such as HTML, CSS and JavaScript. WebPDA is control system independent, potentially supporting any type of control system.« less
Projector Center: Replication, Transcription, and Translation.
ERIC Educational Resources Information Center
Ruth, Edward B.
1984-01-01
Describes the use of a chart that systematically summarizes three basic steps that involve DNA and its decoding in both eukaryotic and prokaryotic cells: replication; transcription, and translation. Indicates that the chart (mounted on a tranparency) does an adequate job of conveying basic information about nucleic acids to students. (DH)
The Christensen Rhetoric Program.
ERIC Educational Resources Information Center
Tufte, Virginia
1969-01-01
Designed to instruct teachers as well as high school or college students in improving their writing, the Christensen Rhetoric Program is a sequential, cumulative program, published in kit form. The kit includes a script with lectures for the teacher, directions for using 200 transparencies on an overhead projector, and student workbooks which…
Comparison of Pictorial Techniques for Guiding Performance During Training.
ERIC Educational Resources Information Center
Miller, Elmo E.
An experimental program was conducted to develop effective methods for producing and utilizing filmed demonstrations and instructional manuals. Four variations on conventional filmed demonstrations were evaluated: 1) revising an Army film through repeated tryouts with novices, 2) stopping the projector after each step is demonstrated to allow…
An Overhead Projection Demonstration of Optical Activity
ERIC Educational Resources Information Center
Hill, John W.
1973-01-01
Describes the use of two polarizing lenses, a yellow filter, an oatmeal bos, a piece of cardboard, a 1,000 ml beaker, and an overhead projector to demonstrate compound optical activity to large classes. Indicates the presence of an accuracy within 1-2 degrees of usually acceptable data. (CC)
Liquid crystal television custom drive circuit
NASA Astrophysics Data System (ADS)
Loudin, Jeffrey A.
1994-03-01
A new drive circuit for the liquid crystal display (LCD) of the InFocus TVT-6000TM video projector is currently under development at the U.S. Army Missile Command. The new circuit will allow individual pixel control of the LCD. This paper will discuss results of the effort to date.
Thinking Images: Doing Philosophy in Film and Video
ERIC Educational Resources Information Center
Parkes, Graham
2009-01-01
Over the past several decades film and video have been steadily infiltrating the philosophy curriculum at colleges and universities. Traditionally, teachers of philosophy have not made much use of "audiovisual aids" in the classroom beyond the chalk board or overhead projector, with only the more adventurous playing audiotapes, for example, or…
Projector Center: Slide-Tape Presentations on a Classroom Budget.
ERIC Educational Resources Information Center
Barman, Charles R., Ed.
1984-01-01
Presented is a recommended sequence for developing a slide-tape presentation. Steps include selecting a topic, determining objectives for the presentation, constructing a storyboard, writing the script, and recording the script. Comments on use of quotation, sound effects, built-in pauses, and use of student voices are included. (JN)
Teaching Techniques for the ESL Literacy Classroom. [Videotape.
ERIC Educational Resources Information Center
Gati, Sally
This 71-minute videotape presents a three-part program of classroom teaching techniques for teachers of English-as-a-Second-Language (ESL) literacy students. It shows students interacting with ESL literacy teachers, and focuses on: (1) essential teaching tools (chalkboard, easel, overhead projector, butcher paper, realia, pictures, flash cards,…
Technology in the Teaching of Composition.
ERIC Educational Resources Information Center
Briand, Paul L., Jr.
The use of technology in teaching composition, which has increased in recent years, began with a few filmstrips on grammar. Then slide-tape presentations were used to stimulate writing, and overhead projectors helped in evaluating writing in class. Now, videocassettes are used to record commonly repeated minilectures and minilessons on spelling,…
ERIC Educational Resources Information Center
Crosscombe, Nigel
2018-01-01
This paper considers how the meaning of innovation has changed over time and considers how contemporary conceptions of innovation are problematic for education. The popularity of the overhead projector in schools during the 1960s is examined to show how education innovation relies on a novel new product for classrooms and a belief by adopters that…
Notions of Technology and Visual Literacy
ERIC Educational Resources Information Center
Stankiewicz, Mary Ann
2004-01-01
For many art educators, the word "technology" conjures up visions of overhead projectors and VCRs, video and digital cameras, computers equipped with graphic programs and presentation software, digital labs where images rendered in pixels replace the debris of charcoal dust and puddled paints. One forgets that visual literacy and technology have…
Building a Better Biology Lab? Testing Tablet PC Technology in a Core Laboratory Course
ERIC Educational Resources Information Center
Pryor, Gregory; Bauer, Vernon
2008-01-01
Tablet PC technology can enliven the classroom environment because it is dynamic, interactive, and "organic," relative to the rigidity of chalkboards, whiteboards, overhead projectors, and PowerPoint presentations. Unlike traditional computers, tablet PCs employ "digital linking," allowing instructors and students to freehand annotate, clarify,…
Laptop Circulation at Eastern Washington University
ERIC Educational Resources Information Center
Munson, Doris; Malia, Elizabeth
2008-01-01
In 2001, Eastern Washington University's Libraries began a laptop circulation program with seventeen laptops. Today, there are 150 laptops in the circulation pool, as well as seventeen digital cameras, eleven digital handycams, and thirteen digital projectors. This article explains how the program has grown to its present size, the growing pains…
ERIC Educational Resources Information Center
Demski, Jennifer
2009-01-01
This article describes how centralized presentation control systems enable IT support staff to monitor equipment and assist end users more efficiently. At Temple University, 70 percent of the classrooms are equipped with an AMX touch panel, linked via a Netlink controller to an in-classroom computer, projector, DVD/VCR player, and speakers. The…
Things the Teacher of Your Media Utilization Course May Not Have Told You.
ERIC Educational Resources Information Center
Ekhaml, Leticia
1995-01-01
Discusses maintenance and safety information that may not be covered in a technology training program. Topics include computers, printers, televisions, video and audio equipment, electric roll laminators, overhead and slide projectors, equipment carts, power cords and outlets, batteries, darkrooms, barcode readers, Liquid Crystal Display units,…
Helping Others to Help Oneself
ERIC Educational Resources Information Center
Pierce, Margo
2012-01-01
Students pick up technology faster than their teacher's. So when it comes to troubleshooting technical headaches in the classroom, it's not surprising that schools are turning to their own best resources--the students themselves. Whether staffing a "genius bar" in the media center or troubleshooting a balky projector, students at some schools are…
A Technology Approach to Improving Process Management
ERIC Educational Resources Information Center
Dray, Lori; Strasburger, Tom
2013-01-01
It is impossible to ignore how technology is infiltrating education. Interactive projectors and other technologies give teachers and students the opportunity to bring lessons to life. Some districts are replacing textbooks with digital content, allowing students to interact with content in new ways. Galion City School District in Galion, Ohio, is…
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC.
Some 75 films from the U.S. Department of Transportation's Federal Aviation Administration are listed in this catalog. Topics dealt with include aerodynamics, airports, aviation history and careers, flying clubs, navigation and weather. Most of the films are 16mm sound and color productions. Filmstrips requiring a 35mm projector and phonograph or…
ERIC Educational Resources Information Center
Greer, Martin L.
Directed to the class or individual with limited film making equipment, this paper presents a "hands on" guide to the production of animated cartoons. Its 14 sections deal with the following topics: understanding animation; choosing subject matter for an animation; writing a script; getting the timing right; choosing a camera and projector;…
ERIC Educational Resources Information Center
Tessmer, Michael; Cowlishaw, Richard
2011-01-01
An introduction to microscopy is common in the elementary curriculum, but microscope work with elementary school children can be a challenge. There is equipment maintenance to consider, as well as the difficulty of using the microscope for many children. These authors have found that using a digital microscope connected to a projector breaks down…
14 CFR 141.55 - Training course: Contents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Training course: Contents. 141.55 Section... Training course: Contents. (a) Each training course for which approval is requested must meet the minimum... trained in the room at one time; (2) A description of each type of audiovisual aid, projector, tape...
Modification of Instructional Delivery and Student Learning with the Use of Educational Technologies
ERIC Educational Resources Information Center
Rogers, Jeffrey Ray
2012-01-01
The purpose of this study was to determine if educational technologies, including LCD projectors, interactive whiteboards, tablets, document cameras, and student response systems, modify instructional delivery and student learning. This case study was researched in four classrooms, including an English, math, science and social studies classroom…
ERIC Educational Resources Information Center
Giles, Rebecca M.; Shaw, Edward L.
2011-01-01
SMART Board is a technology that combines the functionality of a whiteboard, computer, and projector into a single system. The interactive nature of the SMART Board offers many practical uses for providing an introduction to or review of material, while the large work area invites collaboration through social interaction and communication. As a…
ERIC Educational Resources Information Center
Waters, John K.
2007-01-01
Information technology (IT) departments are ruled by a kind of Maslow's Hierarchy of Needs: The big-tech stuff--the operating systems, the networks, the data centers--gets the priority, food-and-shelter attention, while upgrading the backup power supplies, evaluating new projector mounts, and taming that rat's nest of classroom cords fall…
Students' Attitudes towards Control Methods in Computer-Assisted Instruction.
ERIC Educational Resources Information Center
Hintze, Hanne; And Others
1988-01-01
Describes study designed to investigate dental students' attitudes toward computer-assisted teaching as applied in programs for oral radiology in Denmark. Programs using personal computers and slide projectors with varying degrees of learner and teacher control are described, and differences in attitudes between male and female students are…
Brevard Community Colege: Instructional Innovation for the Space Age
ERIC Educational Resources Information Center
King, Maxwell; Breuder, Robert L.
1977-01-01
A description of the Astronaut Memorial Hall and Planetarium at Brevard Community College. Its space museum contains space hardware from Mercury, Gemini, Apollo. A teaching observatory includes radio-telescope laboratory, 40 seat classroom, heliostat room. The planetarium features a computerized starfield projector, wrap-around dome, and ramped…
ERIC Educational Resources Information Center
Taufen, Phyllis M.
There is a simple but effective process for developing public speakers in elementary and junior high schools. After discussing the importance of effective speaking, the teacher puts a topic sentence, on favorite desserts for example, on the board or overhead projector and students think of their favorite desserts and some related words and…
ERIC Educational Resources Information Center
Edmund Scientific Co., Barrington, NJ.
For those who wish to enter the world of light shows, this handbook provides facts, ideas, techniques, suggestions, and sources for the many hard-to-get materials and products. Blacklight, flashing light, musicvision, and lumia (the anti-shape) are discussed. Instructions are given on how to create special effects with overhead projectors, 35mm.…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-16
... October 21, 2011, as supplemented on November 2, 2011, by Compound Photonics Ltd. of London, United Kingdom and Compound Photonics U.S. Corporation of Phoenix, Arizona (collectively ``Compound Photonics... Unfair Import Investigation was named as a participating party. On October 17, 2012, Compound Photonics...
Future View: Web Navigation based on Learning User's Browsing Strategy
NASA Astrophysics Data System (ADS)
Nagino, Norikatsu; Yamada, Seiji
In this paper, we propose a Future View system that assists user's usual Web browsing. The Future View will prefetch Web pages based on user's browsing strategies and present them to a user in order to assist Web browsing. To learn user's browsing strategy, the Future View uses two types of learning classifier systems: a content-based classifier system for contents change patterns and an action-based classifier system for user's action patterns. The results of learning is applied to crawling by Web robots, and the gathered Web pages are presented to a user through a Web browser interface. We experimentally show effectiveness of navigation using the Future View.
ERIC Educational Resources Information Center
Bordeianu, Sever; Carter, Christina E.; Dennis, Nancy K.
2000-01-01
Describes Web-based online public access catalogs (Web OPACs) and other Web-based tools as gateway methods for providing access to library collections. Addresses solutions for overcoming barriers to information, such as through the implementation of proxy servers and other authentication tools for remote users. (Contains 18 references.)…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-12
...-FF08EACT00] Trinity Adaptive Management Working Group; Public Meeting, Teleconference and Web-Based Meeting... Service, announce a public meeting, teleconference and web-based meeting of the Trinity Adaptive Management Working Group (TAMWG). DATES: Public meeting, Teleconference, and web-based meeting: Tuesday June...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
...-FF08EACT00] Trinity Adaptive Management Working Group; Public Meeting, Teleconference and Web-Based Meeting... Service, announce a public meeting, teleconference, and web-based meeting of the Trinity Adaptive Management Working Group (TAMWG). DATES: Public meeting, Teleconference, and web-based meeting: Tuesday...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-20
...-FF08EACT00] Trinity Adaptive Management Working Group; Public Meeting, Teleconference and Web-Based Meeting... Service, announce a public meeting, teleconference and web-based meeting of the Trinity Adaptive Management Working Group (TAMWG). DATES: Public meeting, Teleconference, and web-based meeting: Monday April...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-15
... DEPARTMENT OF DEFENSE Office of the Secretary Termination of the Department of Defense Web-Based..., entitled Web-Based TRICARE Assistance Program (TRIAP). The demonstration project uses existing health care support contracts (HCSC) to allow web-based behavioral health and related services including non-medical...
76 FR 12073 - Extension of Web-Based TRICARE Assistance Program Demonstration Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-04
... DEPARTMENT OF DEFENSE Office of the Secretary Extension of Web-Based TRICARE Assistance Program Demonstration Program AGENCY: Department of Defense. ACTION: Notice of a Two Year Extension of the Web-Based..., entitled Web-Based TRICARE Assistance Program. This demonstration was effective August 1, 2009, as...
Overbeek, Annelies; van der Pal, Helena J; Versluys, A. Birgitta; Bresters, Dorine; van Leeuwen, Flora E; Lambalk, Cornelis B; Kaspers, Gertjan J.L; van Dulmen-den Broeder, Eline
2011-01-01
Background Web-based questionnaires have become increasingly popular in health research. However, reported response rates vary and response bias may be introduced. Objective The aim of this study was to evaluate whether sending a mixed invitation (paper-based together with Web-based questionnaire) rather than a Web-only invitation (Web-based questionnaire only) results in higher response and participation rates for female childhood cancer survivors filling out a questionnaire on fertility issues. In addition, differences in type of response and characteristics of the responders and nonresponders were investigated. Moreover, factors influencing preferences for either the Web- or paper-based version of the questionnaire were examined. Methods This study is part of a nationwide study on reproductive function, ovarian reserve, and risk of premature menopause in female childhood cancer survivors. The Web-based version of the questionnaire was available for participants through the Internet by means of a personalized user name and password. Participants were randomly selected to receive either a mixed invitation (paper-based questionnaire together with log-in details for Web-based questionnaire, n = 137) or a Web-only invitation (log-in details only, n = 140). Furthermore, the latter group could request a paper-based version of the questionnaire by filling out a form. Results Overall response rates were comparable in both randomization groups (83% mixed invitation group vs 89% in Web-only invitation group, P = .20). In addition, participation rates appeared not to differ (66% or 90/137, mixed invitation group vs 59% or 83/140, Web-only invitation group, P =.27). However, in the mixed invitation group, significantly more respondents filled out the paper-based questionnaire compared with the Web-only invitation group (83% or 75/90 and 65% or 54/83, respectively, P = .01). The 44 women who filled out the Web-based version of the questionnaire had a higher educational level than the 129 women who filled out the paper-based version (P = .01). Furthermore, the probability of filling out the Web-based questionnaire appeared to be greater for women who were allocated to the Web-only invitation group (OR = 2.85, 95% CI 1.31 - 6.21), were older (OR = 1.08, 95% CI 1.02 - 1.15), had a higher educational level (OR high vs low = 0.06, 95% CI 0.01 - 0.52), or were students (OR employed vs student = 3.25, 95% CI 1.00 - 10.56). Conclusions Although overall response as well as participation rates to both types of invitations were similar, adding a paper version of a questionnaire to a Web-only invitation resulted in more respondents filling out the paper-based version. In addition, women who were older, had a higher level of education, or were students, were more likely to have filled out the Web-based version of the questionnaire. Given the many advantages of Web-based over paper-based questionnaires, researchers should strongly consider using Web-based questionnaires, although possible response bias when using these types of questionnaires should be taken into account. Trial Registration Nederlands Trial Register NTR2922; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2922 (Archived by WebCite at http://www.webcitation.org/5zRRdMrDv) PMID:21955527