76 FR 33303 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-08
... comments should be received within 60 days of this notice. Proposed Project Survey of Rapid Influenza... Description The Survey of Rapid Influenza Diagnostic Testing Practices in Clinical Laboratories is a national systematic study investigating rapid influenza diagnostic testing practices in clinical [[Page 33304...
A New Procedure for Detection of Students' Rapid Guessing Responses Using Response Time
ERIC Educational Resources Information Center
Guo, Hongwen; Rios, Joseph A.; Haberman, Shelby; Liu, Ou Lydia; Wang, Jing; Paek, Insu
2016-01-01
Unmotivated test takers using rapid guessing in item responses can affect validity studies and teacher and institution performance evaluation negatively, making it critical to identify these test takers. The authors propose a new nonparametric method for finding response-time thresholds for flagging item responses that result from rapid-guessing…
78 FR 20112 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
...-related information. The respondents would be clinical laboratory supervisors, nurses, and other.../60 300 Supervisors. Influenza Diagnostic Test Practices in Clinical Laboratories. Nurses Survey of... this notice. Proposed Project Survey of Rapid Influenza Diagnostic Test (RIDT) Practices in Clinical...
77 FR 24211 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-23
... through the use of automated collection techniques or other forms of information technology. Proposed... designated OTP site History (Screening) of Hepatitis C exposure Results of Rapid Hepatitis C Testing (Kit...
Uhlmann, Wendy R.; Sharp, Richard R.
2014-01-01
There has been a dramatic increase in the number of genetic tests available but few tests have practice guidelines. In addition, many tests have become available outside of genetics clinics through direct-to-consumer (DTC) companies and several offer tests not considered standard of care. To address several practical challenges associated with the rapid introduction of clinical and DTC genetic tests, we propose that genetic counselors and geneticists organize expert panels in their institutions to discuss the integration of new tests into patient care. We propose the establishment of Genetic Testing Integration Panels (GTIPs) to bring together local experts in medical genetics, genetic counseling, bioethics and law, health communication and clinical laboratory genetics. We describe key features of this approach and consider some of the potential advantages and limitations of using a GTIP to address the many clinical challenges raised by rapidly emerging clinical and DTC genetic tests. PMID:22246561
Improvement of a rapid screening test for chronic granulomatous disease.
Iacobini, M; Duse, M; Di Coste, A; Balducci, L
2013-01-01
Diagnosis of CGD is made by demonstrating absent or markedly reduced oxidase activity in stimulated neutrophils. The screening test proposed is based upon the naked eye evaluation of the reduction of NBT on a solid surface. It seems to be a useful tool for rapid and inexpensive detection of CGD patients, especially for large-scale screening purposes. The test was carried out on forty-five subjects: two males affected by CGD, three female carriers and forty healthy donors. The test confirmed the results obtained with flow cytometric and NBT assays.
A proposed new test for aptitude screening of air traffic controller applicants.
DOT National Transportation Integrated Search
1972-05-01
The study concerns the development and experimental validation of a novel aptitude test, referred to as 'Directional Headings' (or DHT), for the selection of Air Traffic Control Specialist (ATCS) trainees. The test requires the subject to rapidly int...
Zanchi, Chiara; Ventura, Alessandro; Martelossi, Stefano; Di Leo, Grazia; Di Toro, Nicola; Not, Tarcisio
2013-06-01
The anti-transglutaminase antibodies (anti-tTG) play an important role in monitoring the celiacs' gluten-free diet (GFD). The authors propose to use the rapid IgA anti-tTG assay based on a whole blood drop to evaluate the compliance to GFD at the clinical ambulatory setting. The rapid test results were compared with those of the conventional ELISA assay and with dietary compliance reported by patients' interview. The authors showed that anti-tTG rapid test is reliable and easy to perform in the ambulatory setting to evaluate dietary compliance. Moreover, they proved that celiacs' interview is more sensitive than serology in identifying patients who transgress.
NASA Astrophysics Data System (ADS)
Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang
2016-02-01
Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.
77 FR 21984 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Substance Abuse and Mental Health Services Administration... proposed collections of information, the Substance Abuse and Mental Health Services Administration (SAMHSA... results, substance use and sexual risk behaviors, current rapid HIV test results, types of services...
Does knowledge brokering improve the quality of rapid review proposals? A before and after study.
Moore, Gabriel; Redman, Sally; D'Este, Catherine; Makkar, Steve; Turner, Tari
2017-01-28
Rapid reviews are increasingly being used to help policy makers access research in short time frames. A clear articulation of the review's purpose, questions, scope, methods and reporting format is thought to improve the quality and generalisability of review findings. The aim of the study is to explore the effectiveness of knowledge brokering in improving the perceived clarity of rapid review proposals from the perspective of potential reviewers. To conduct the study, we drew on the Evidence Check program, where policy makers draft a review proposal (a pre knowledge brokering proposal) and have a 1-hour session with a knowledge broker, who re-drafts the proposal based on the discussion (a post knowledge brokering proposal). We asked 30 reviewers who had previously undertaken Evidence Check reviews to examine the quality of 60 pre and 60 post knowledge brokering proposals. Reviewers were blind to whether the review proposals they received were pre or post knowledge brokering. Using a six-point Likert scale, reviewers scored six questions examining clarity of information about the review's purpose, questions, scope, method and format and reviewers' confidence that they could meet policy makers' needs. Each reviewer was allocated two pre and two post knowledge brokering proposals, randomly ordered, from the 60 reviews, ensuring no reviewer received a pre and post knowledge brokering proposal from the same review. The results showed that knowledge brokering significantly improved the scores for all six questions addressing the perceived clarity of the review proposal and confidence in meeting policy makers' needs; with average changes of 0.68 to 1.23 from pre to post across the six domains. This study found that knowledge brokering increased the perceived clarity of information provided in Evidence Check rapid review proposals and the confidence of reviewers that they could meet policy makers' needs. Further research is needed to identify how the knowledge brokering process achieves these improvements and to test the applicability of the findings in other rapid review programs.
Modeling Student Test-Taking Motivation in the Context of an Adaptive Achievement Test
ERIC Educational Resources Information Center
Wise, Steven L.; Kingsbury, G. Gage
2016-01-01
This study examined the utility of response time-based analyses in understanding the behavior of unmotivated test takers. For the data from an adaptive achievement test, patterns of observed rapid-guessing behavior and item response accuracy were compared to the behavior expected under several types of models that have been proposed to represent…
Diserens, Esther-Amélie; Bodenmann, Patrick; N'Garambe, Chantal; Ansermet-Pagot, Anne; Vannotti, Marco; Masserey, Eric; Cavassini, Matthias
2010-03-19
Clients of street sex workers may be at higher risk for HIV infection than the general population. Furthermore, there is a lack of knowledge regarding HIV testing of clients of sex workers in developed countries. This pilot study assessed the feasibility and acceptance of rapid HIV testing by the clients of street-based sex workers in Lausanne, Switzerland. For 5 evenings, clients in cars were stopped by trained field staff for face-to-face interviews focusing on sex-related HIV risk behaviors and HIV testing history. The clients were then offered a free anonymous rapid HIV test in a bus parked nearby. Rapid HIV testing and counselling were performed by experienced nurse practitioners. Clients with reactive tests were offered confirmatory testing, medical evaluation, and care in our HIV clinic. We intercepted 144 men, 112 (77.8%) agreed to be interviewed. Among them, 50 (46.6%) had never been tested for HIV. A total of 31 (27.7%) rapid HIV tests were performed, 16 (51.6%) in clients who had not previously been tested. None were reactive. Initially, 19 (16.9%) additional clients agreed to HIV testing but later declined due to the 40-minute queue for testing. This pilot study showed that rapid HIV testing in the red light district of Lausanne was feasible, and that the clients of sex workers accepted testing at an unexpectedly high rate. This setting seems particularly appropriate for targeted HIV screening, since more than 40% of the clients had not previously been tested for HIV even though they engaged in sex-related HIV risk behaviour.
Multichannel microfluidic chip for rapid and reliable trapping and imaging plant-parasitic nematodes
NASA Astrophysics Data System (ADS)
Amrit, Ratthasart; Sripumkhai, Witsaroot; Porntheeraphat, Supanit; Jeamsaksiri, Wutthinan; Tangchitsomkid, Nuchanart; Sutapun, Boonsong
2013-05-01
Faster and reliable testing technique to count and identify nematode species resided in plant roots is therefore essential for export control and certification. This work proposes utilizing a multichannel microfluidic chip with an integrated flow-through microfilter to retain the nematodes in a trapping chamber. When trapped, it is rather simple and convenient to capture images of the nematodes and later identify their species by a trained technician. Multiple samples can be tested in parallel using the proposed microfluidic chip therefore increasing number of samples tested per day.
Screening tests for the rapid detection of diarrhetic shellfish toxins in Washington State.
Eberhart, Bich-Thuy L; Moore, Leslie K; Harrington, Neil; Adams, Nicolaus G; Borchert, Jerry; Trainer, Vera L
2013-09-30
The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test "pre-harvest" shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer's recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters.
Screening Tests for the Rapid Detection of Diarrhetic Shellfish Toxins in Washington State
Eberhart, Bich-Thuy L.; Moore, Leslie K.; Harrington, Neil; Adams, Nicolaus G.; Borchert, Jerry; Trainer, Vera L.
2013-01-01
The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test “pre-harvest” shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer’s recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters. PMID:24084788
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jun; Tang, Zhilie; Wu, Yongbo
2015-04-15
We designed, fabricated, and tested a rapid and noncontact photoacoustic tomography (PAT) imaging system using a low-coherence interferometer with high-speed phase modulation technique. Such a rapid and noncontact probing system can greatly decrease the time of imaging. The proposed PAT imaging system is experimentally verified by capturing images of a simulated tissue sample and the blood vessels within the ear flap of a mouse (pinna) in vivo. The axial and lateral resolutions of the system are evaluated at 45 and ∼15 μm, respectively. The imaging depth of the system is 1 mm in a special phantom. Our results show thatmore » the proposed system opens a promising way to realize noncontact, real-time PAT.« less
DOT National Transportation Integrated Search
1973-04-01
A prototype Uniflo vehicle base with mock-up superstructure was tested on 55 ft. of full-scale track. Sound treatment to meet NCA 60 at 25 ft. from the guideway enclosure and within the vehicle was proposed and the costs determined. A heating and coo...
Combustion of Coal/Oil/Water Slurries
NASA Technical Reports Server (NTRS)
Kushida, R. O.
1982-01-01
Proposed test setup would measure combustion performance of new fuels by rapidly heating a droplet of coal/oil/water mixture and recording resulting explosion. Such mixtures are being considered as petroleum substitutes in oil-fired furnaces.
[Evaluation of the new ImmunoCard STAT!® CGE test for the diagnosis of Amebiasis].
Formenti, F; Perandin, F; Bonafini, S; Degani, M; Bisoffi, Z
2015-08-01
For many years, microscopic examination of stool samples has been considered to be the "gold standard" for diagnosis of intestinal parasites although the Polymerase Chain Reaction (PCR) analysis is increasingly utilized due to its high accuracy. Recently, PCR has been approved by the World Health Organization as the current method of choice for the diagnosis of Entamoeba histolytica infection. In this study we evaluated a novel immunochromatographic antigen detection rapid test, ImmunoCardSTAT CGE (Meridian Bioscence, Milan, Italy), which has been proposed for the diagnosis of infections caused by Cryptosporidium parvum-Giardia intestinalis-Entamoeba histolytica. There is another rapid test with a similar name, the ImmunoCard STAT! Crypto/Giardia, but it is just for Cryptosporidium and Giardia. We aimed to compare E. histolytica results obtained from the rapid test with those of a rt-PCR for the detection of E. histolytica / E. dispar DNA. The new ImmunoCard rapid antigen detection test exhibited 88% sensitivity and 92% specificity (if assessed on rt-PCR negative samples) but showed a high proportion of cross-reaction between the pathogenic E. histolytica and the non pathogenic E. dispar.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhaohui; Wang, Ying; Wang, Jun
2010-08-15
A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescencemore » intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.« less
Han, Buhm; Kang, Hyun Min; Eskin, Eleazar
2009-01-01
With the development of high-throughput sequencing and genotyping technologies, the number of markers collected in genetic association studies is growing rapidly, increasing the importance of methods for correcting for multiple hypothesis testing. The permutation test is widely considered the gold standard for accurate multiple testing correction, but it is often computationally impractical for these large datasets. Recently, several studies proposed efficient alternative approaches to the permutation test based on the multivariate normal distribution (MVN). However, they cannot accurately correct for multiple testing in genome-wide association studies for two reasons. First, these methods require partitioning of the genome into many disjoint blocks and ignore all correlations between markers from different blocks. Second, the true null distribution of the test statistic often fails to follow the asymptotic distribution at the tails of the distribution. We propose an accurate and efficient method for multiple testing correction in genome-wide association studies—SLIDE. Our method accounts for all correlation within a sliding window and corrects for the departure of the true null distribution of the statistic from the asymptotic distribution. In simulations using the Wellcome Trust Case Control Consortium data, the error rate of SLIDE's corrected p-values is more than 20 times smaller than the error rate of the previous MVN-based methods' corrected p-values, while SLIDE is orders of magnitude faster than the permutation test and other competing methods. We also extend the MVN framework to the problem of estimating the statistical power of an association study with correlated markers and propose an efficient and accurate power estimation method SLIP. SLIP and SLIDE are available at http://slide.cs.ucla.edu. PMID:19381255
Monitoring of rapid blood pH variations by CO detection in breath with tunable diode laser
NASA Astrophysics Data System (ADS)
Kouznetsov, Andrian I.; Stepanov, Eugene V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Diachenko, Alexander I.; Gurfinkel, Youri I.
1997-06-01
Detection of endogenous carbon monoxide content in breath with tunable diode lasers (TDL) was proposed for noninvasive monitoring of rapid blood pH variation. Applied approach is based on high sensitivity of the haemoglobin and myoglobin affinity for CO to blood pH value and an ability to detect rapidly small variations of CO content in expired air. Breath CO absorption in 4.7 micrometers spectral region was carefully measured using PbSSe tunable diode laser that can provide 1 ppb CO concentration sensitivity and 10 s time constant. Applied TDL gas analyzer was used to monitor expired air of studied persons in physiological tests including hyperventilation and physical load. Simultaneous blood tests were conducted to demonstrate correlation between blood and breath chemical parameters.
Improved Cell Sensitivity and Longevity in a Rapid Impedance-based Toxicity Sensor
2009-01-06
sensitivity and longevity in a rapid impedance-based toxicity sensor† Improved cell sensitivity and longevityTheresa M. Curtis,a** Joel Tabb,a Lori...Romeo,a Steven J. Schwager,b Mark W. Widderc* and William H. van der Schaliec ABSTRACT: A number of toxicity sensors for testing field water using a...range of eukaryotic cell types have been proposed, but it has been difficult to identify sensors with both appropriate sensitivity to toxicants and the
Proposed aeroelastic and flutter tests for the National Transonic Facility
NASA Technical Reports Server (NTRS)
Stevenson, J. R.
1981-01-01
Tests that can exploit the capability of the NTF and the transonic cryogenic tunnel, or lead to improvements that could enhance testing in the NTF are discussed. Shock induced oscillation, supersonic single degree control surface flutter, and transonic flutter speed as a function of the Reynolds number are considered. Honeycombs versus screens to smooth the tunnel flow and a rapid tunnel dynamic pressure reducer are recommended to improve tunnel performance.
Shareef, Hussain; Mohamed, Azah
2017-01-01
The electric vehicle (EV) is considered a premium solution to global warming and various types of pollution. Nonetheless, a key concern is the recharging of EV batteries. Therefore, this study proposes a novel approach that considers the costs of transportation loss, buildup, and substation energy loss and that incorporates harmonic power loss into optimal rapid charging station (RCS) planning. A novel optimization technique, called binary lightning search algorithm (BLSA), is proposed to solve the optimization problem. BLSA is also applied to a conventional RCS planning method. A comprehensive analysis is conducted to assess the performance of the two RCS planning methods by using the IEEE 34-bus test system as the power grid. The comparative studies show that the proposed BLSA is better than other optimization techniques. The daily total cost in RCS planning of the proposed method, including harmonic power loss, decreases by 10% compared with that of the conventional method. PMID:29220396
Islam, Md Mainul; Shareef, Hussain; Mohamed, Azah
2017-01-01
The electric vehicle (EV) is considered a premium solution to global warming and various types of pollution. Nonetheless, a key concern is the recharging of EV batteries. Therefore, this study proposes a novel approach that considers the costs of transportation loss, buildup, and substation energy loss and that incorporates harmonic power loss into optimal rapid charging station (RCS) planning. A novel optimization technique, called binary lightning search algorithm (BLSA), is proposed to solve the optimization problem. BLSA is also applied to a conventional RCS planning method. A comprehensive analysis is conducted to assess the performance of the two RCS planning methods by using the IEEE 34-bus test system as the power grid. The comparative studies show that the proposed BLSA is better than other optimization techniques. The daily total cost in RCS planning of the proposed method, including harmonic power loss, decreases by 10% compared with that of the conventional method.
RAPID ASSESSMENT OF URBAN WETLANDS: FUNCTIONAL ASSESSMENT MODEL DEVELOPMENT AND EVALUATION
The objective of this study was to test the ability of existing hydrogeomorphic (HGM) functional assessment models and our own proposed models to predict rates of nitrate production and removal, functions critical to water quality protection, in forested riparian wetlands in nort...
Thousands of untested chemicals in the environment require efficient characterization of carcinogenic potential in humans. A proposed solution is rapid testing of chemicals using in vitro high-throughput screening (HTS) assays for targets in pathways linked to disease processes ...
Eugenics and Mandatory Informed Prenatal Genetic Testing: A Unique Perspective from China.
Zhang, Di; Ng, Vincent H; Wang, Zhaochen; Zhai, Xiaomei; Lie, Reidar K
2016-08-01
The application of genetic technologies in China, especially in the area of prenatal genetic testing, is rapidly increasing in China. In the wealthy regions of China, prenatal genetic testing is already very widely adopted. We argue that the government should actively promote prenatal genetic testing to the poor areas of the country. In fact, the government should prioritize resources first to make prenatal genetic testing a standard routine care with an opt-out model in these area. Healthcare professions would be required to inform pregnant women about the availability of genetic testing and provide free testing on a routine basis unless the parents choose not to do so. We argue that this proposal will allow parents to make a more informed decision about their reproductive choices. Secondarily, this proposal will attract more healthcare professionals and other healthcare resources to improve the healthcare infrastructures in the less-developed regions of the country. This will help to reduce the inequity of accessing healthcare services between in different regions of China. We further argue that this policy proposal is not practicing eugenics. © 2015 John Wiley & Sons Ltd.
Portero, José-Luis; Rubio-Yuste, Maria; Descalzo, Miguel Angel; Raso, Jose; Lwanga, Magdalena; Obono, Jaquelina; Nseng, Gloria; Benito, Agustin; Cano, Jorge
2010-01-01
Conventional malaria diagnosis based on microscopy raises serious difficulties in weak health systems. Cost-effective and sensitive rapid diagnostic tests have been recently proposed as alternatives to microscopy. In Equatorial Guinea, a study was conducted to assess the reliability of a rapid diagnostic test compared to microscopy. The study was designed in accordance with the directives of the Standards for Reporting Diagnostic Accuracy Initiative (STARD). Peripheral thick and thin films for the microscopy diagnosis and a rapid immunochromatographic test (ICT Malaria Combo Cassette Test) were performed on under five-year-old children with malaria suspicion. The ICT test detected Plasmodium spp. infection with a sensitivity of 81.5% and a specificity of 81.9% while P. falciparum diagnosis occurred with a sensitivity of 69.7% and a specificity of 73.7%. The sensitivity of the ICT test increased with higher parasitemias. The general results showed little concordance between the ICT test and microscopy (kappa = 0.28, se: 0.04). In Equatorial Guinea, the ICT Malaria Combo Cassette Test has proven to be an acceptable test to detect high P. falciparum parasitemias. However, the decrease of sensitivity at medium and low parasitemias hampers that ICT can replace properly performed microscopy at present in the diagnosis of malaria in children. PMID:22332024
Masciotra, Silvina; Smith, Amanda J; Youngpairoj, Ae S; Sprinkle, Patrick; Miles, Isa; Sionean, Catlainn; Paz-Bailey, Gabriela; Johnson, Jeffrey A; Owen, S Michele
2013-12-01
Until recently most testing algorithms in the United States (US) utilized Western blot (WB) as the supplemental test. CDC has proposed an algorithm for HIV diagnosis which includes an initial screen with a Combo Antigen/Antibody 4th generation-immunoassay (IA), followed by an HIV-1/2 discriminatory IA of initially reactive-IA specimens. Discordant results in the proposed algorithm are resolved by nucleic acid-amplification testing (NAAT). Evaluate the results obtained with the CDC proposed laboratory-based algorithm using specimens from men who have sex with men (MSM) obtained in five metropolitan statistical areas (MSAs). Specimens from 992 MSM from five MSAs participating in the CDC's National HIV Behavioral Surveillance System in 2011 were tested at local facilities and CDC. The five MSAs utilized algorithms of various screening assays and specimen types, and WB as the supplemental test. At the CDC, serum/plasma specimens were screened with 4th generation-IA and the Multispot HIV-1/HIV-2 discriminatory assay was used as the supplemental test. NAAT was used to resolve discordant results and to further identify acute HIV infections from all screened-non-reactive missed by the proposed algorithm. Performance of the proposed algorithm was compared to site-specific WB-based algorithms. The proposed algorithm detected 254 infections. The WB-based algorithms detected 19 fewer infections; 4 by oral fluid (OF) rapid testing and 15 by WB supplemental testing (12 OF and 3 blood). One acute infection was identified by NAAT from all screened-non-reactive specimens. The proposed algorithm identified more infections than the WB-based algorithms in a high-risk MSM population. OF testing was associated with most of the discordant results between algorithms. HIV testing with the proposed algorithm can increase diagnosis of infected individuals, including early infections. Published by Elsevier B.V.
Knight, Jean; Rovida, Costanca
2014-01-01
The proposed Safe Cosmetics and Personal Care Products Act of 2013 calls for a new evaluation program for cosmetic ingredients in the US, with the new assessments initially dependent on expanded animal testing. This paper considers possible testing scenarios under the proposed Act and estimates the number of test animals and cost under each scenario. It focuses on the impact for the first 10 years of testing, the period of greatest impact on animals and costs. The analysis suggests the first 10 years of testing under the Act could evaluate, at most, about 50% of ingredients used in cosmetics. Testing during this period would cost about $ 1.7-$ 9 billion and 1-11.5 million animals. By test year 10, alternative, high-throughput test methods under development are expected to be available, replacing animal testing and allowing rapid evaluation of all ingredients. Given the high cost in dollars and animal lives of the first 10 years for only about half of ingredients, a better choice may be to accelerate development of high-throughput methods. This would allow evaluation of 100% of cosmetic ingredients before year 10 at lower cost and without animal testing.
Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests.
Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline; Lindegren, Gunnel; Stoltz, Malin Lundahl; Salata, Cristiano; Kran, Anne-Marte Bakken; Dudman, Susanne Gjeruldsen; Mirazimi, Ali; Fomsgaard, Anders
2016-10-01
Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using the QIAamp viral RNA minikit. We present an easy and convenient method for bedside inactivation using available blood collection vacuum tubes and reagents. We propose to use this simple method for fast, safe, and easy bedside inactivation of Ebola virus for safe transport and routine nucleic acid detection. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
On testing models for the pressure-strain correlation of turbulence using direct simulations
NASA Technical Reports Server (NTRS)
Speziale, Charles G.; Gatski, Thomas B.; Sarkar, Sutanu
1992-01-01
Direct simulations of homogeneous turbulence have, in recent years, come into widespread use for the evaluation of models for the pressure-strain correlation of turbulence. While work in this area has been beneficial, the increasingly common practice of testing the slow and rapid parts of these models separately in uniformly strained turbulent flows is shown in this paper to be unsound. For such flows, the decomposition of models for the total pressure-strain correlation into slow and rapid parts is ambiguous. Consequently, when tested in this manner, misleading conclusions can be drawn about the performance of pressure-strain models. This point is amplified by illustrative calculations of homogeneous shear flow where other pitfalls in the evaluation of models are also uncovered. More meaningful measures for testing the performance of pressure-strain models in uniformly strained turbulent flows are proposed and the implications for turbulence modeling are discussed.
Tectonic tests of proposed polar wander paths for Mars and the moon
NASA Technical Reports Server (NTRS)
Grimm, R. E.; Solomon, S. C.
1986-01-01
A comparison of the lithospheric stress field predicted for rapid global reorientations against observed tectonic features is used to test the polar wander paths proposed for Mars by Schultz and Lutz-Garihan (1981). A calculation of the reorientation stresses leads to the suggestion that the formation of normal faults or graben in broad regions around the former rotation poles should be the minimum tectonic signature of a reorientation that generates lithospheric stresses in excess of the extensional strength of near-surface material. It is concluded that polar wander of the magnitude and timing envisioned by Schultz and Lutz-Garihan did not occur.
Gülay, Arda; Smets, Barth F
2015-09-01
Exploring the variation in microbial community diversity between locations (β diversity) is a central topic in microbial ecology. Currently, there is no consensus on how to set the significance threshold for β diversity. Here, we describe and quantify the technical components of β diversity, including those associated with the process of subsampling. These components exist for any proposed β diversity measurement procedure. Further, we introduce a strategy to set significance thresholds for β diversity of any group of microbial samples using rarefaction, invoking the notion of a meta-community. The proposed technique was applied to several in silico generated operational taxonomic unit (OTU) libraries and experimental 16S rRNA pyrosequencing libraries. The latter represented microbial communities from different biological rapid sand filters at a full-scale waterworks. We observe that β diversity, after subsampling, is inflated by intra-sample differences; this inflation is avoided in the proposed method. In addition, microbial community evenness (Gini > 0.08) strongly affects all β diversity estimations due to bias associated with rarefaction. Where published methods to test β significance often fail, the proposed meta-community-based estimator is more successful at rejecting insignificant β diversity values. Applying our approach, we reveal the heterogeneous microbial structure of biological rapid sand filters both within and across filters. © 2014 Society for Applied Microbiology and John Wiley & Sons Ltd.
Rapid repair of severely earthquake-damaged bridge piers with flexural-shear failure mode
NASA Astrophysics Data System (ADS)
Sun, Zhiguo; Wang, Dongsheng; Du, Xiuli; Si, Bingjun
2011-12-01
An experimental study was conducted to investigate the feasibility of a proposed rapid repair technique for severely earthquake-damaged bridge piers with flexural-shear failure mode. Six circular pier specimens were first tested to severe damage in flexural-shear mode and repaired using early-strength concrete with high-fluidity and carbon fiber reinforced polymers (CFRP). After about four days, the repaired specimens were tested to failure again. The seismic behavior of the repaired specimens was evaluated and compared to the original specimens. Test results indicate that the proposed repair technique is highly effective. Both shear strength and lateral displacement of the repaired piers increased when compared to the original specimens, and the failure mechanism of the piers shifted from flexural-shear failure to ductile flexural failure. Finally, a simple design model based on the Seible formulation for post-earthquake repair design was compared to the experimental results. It is concluded that the design equation for bridge pier strengthening before an earthquake could be applicable to seismic repairs after an earthquake if the shear strength contribution of the spiral bars in the repaired piers is disregarded and 1.5 times more FRP sheets is provided.
Pattern Separation Deficits Following Damage to the Hippocampus
ERIC Educational Resources Information Center
Kirwan, C. Brock; Hartshorn, Andrew; Stark, Shauna M.; Goodrich-Hunsaker, Naomi J.; Hopkins, Ramona O.; Stark, Craig E. L.
2012-01-01
Computational models of hippocampal function propose that the hippocampus is capable of rapidly storing distinct representations through a process known as pattern separation. This prediction is supported by electrophysiological data from rodents and neuroimaging data from humans. Here, we test the prediction that damage to the hippocampus would…
75 FR 51270 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-19
... involve conducting behavioral assessments and rapid HIV testing at a variety of events serving groups at... profiles and prevalence of unrecognized infection among individuals reachable for HIV counseling and... need for increased behavioral data among some high-risk groups that are more difficult to access or...
75 FR 21630 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... participate in the second phase. Quantitative surveys will be administered by computers and personal... administer a survey, conduct interviews and offer HIV rapid testing in Black Men who have sex with Men (BMSM...-minute eligibility screening interview. The baseline computer-based survey will take 45 minutes. The...
USDA-ARS?s Scientific Manuscript database
Recessive genetic defects are currently on the minds of many cattle breeders. The relatively rapid development of diagnostic DNA tests for recessive defects appears to be a major recent technological advancement. However, the attitude of breeders and breed associations toward recessive defects seems...
NASA Astrophysics Data System (ADS)
Shutov, A. V.; Larichkin, A. Yu
2017-10-01
A cyclic creep damage model, previously proposed by the authors, is modified for a better description of the transient creep of D16T alloy observed in the finite strain range under rapidly changing stresses. The new model encompasses the concept of kinematic hardening, which allows us to account for the creep-induced anisotropy. The model kinematics is based on the nested multiplicative split of the deformation gradient, proposed by Lion. The damage evolution is accounted for by the classical Kachanov-Rabotnov approach. The material parameters are identified using experimental data on cyclic torsion of thick-walled samples with different holding times between load reversals. For the validation of the proposed material model, an additional experiment is analyzed. Although this additional test is not involved in the identification procedure, the proposed cyclic creep damage model describes it accurately.
Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele
2016-07-21
The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.
Learned Predictiveness Influences Rapid Attentional Capture: Evidence from the Dot Probe Task
ERIC Educational Resources Information Center
Le Pelley, Mike E.; Vadillo, Miguel; Luque, David
2013-01-01
Attentional theories of associative learning and categorization propose that learning about the predictiveness of a stimulus influences the amount of attention that is paid to that stimulus. Three experiments tested this idea by looking at the extent to which stimuli that had previously been experienced as predictive or nonpredictive in a…
A Matter of Time: Rapid Motor Memory Stabilization in Childhood
ERIC Educational Resources Information Center
Adi-Japha, Esther; Badir, Rodayna; Dorfberger, Shoshi; Karni, Avi
2014-01-01
Are children better than adults in acquiring new skills ("how-to" knowledge) because of a difference in skill memory consolidation? Here we tested the proposal that, as opposed to adults, children's memories for newly acquired skills are immune to interference by subsequent experience. The establishment of long-term memory for a…
Lussiana, Cristina
2016-01-01
The idea of a private sector subsidy programme of artemisinin-based combination therapies (ACTs) was first proposed in 2004. Since then, several countries around the world have hosted pilot projects or programmes on subsidized ACTs and/or the Affordable Medicines Facility-malaria programme (AMFm). Overall the private sector subsidy programmes of ACTs have been effective in increasing availability of ACTs in the private sector and driving down average prices but struggled to crowd out antimalarial monotherapies. The results obtained from this ambitious strategy should inform policy makers in the designing of future interventions aimed to control malaria morbidity and mortality. Among the interventions recently proposed, a subsidy of rapid diagnostic tests (RDTs) in the private sector has been recommended by governments and international donors to cope with over-treatment with ACTs and to delay the emergence of resistance to artemisinin. In order to improve the cost-effectiveness of co-paid RDTs, we should build on the lessons we learned from almost 10 years of private sector subsidy programmes of ACTs in malaria-endemic countries. PMID:25862732
NASA Astrophysics Data System (ADS)
Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum
2016-06-01
A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c
Effectiveness-implementation Hybrid Designs
Curran, Geoffrey M.; Bauer, Mark; Mittman, Brian; Pyne, Jeffrey M.; Stetler, Cheryl
2013-01-01
Objectives This study proposes methods for blending design components of clinical effectiveness and implementation research. Such blending can provide benefits over pursuing these lines of research independently; for example, more rapid translational gains, more effective implementation strategies, and more useful information for decision makers. This study proposes a “hybrid effectiveness-implementation” typology, describes a rationale for their use, outlines the design decisions that must be faced, and provides several real-world examples. Results An effectiveness-implementation hybrid design is one that takes a dual focus a priori in assessing clinical effectiveness and implementation. We propose 3 hybrid types: (1) testing effects of a clinical intervention on relevant outcomes while observing and gathering information on implementation; (2) dual testing of clinical and implementation interventions/strategies; and (3) testing of an implementation strategy while observing and gathering information on the clinical intervention’s impact on relevant outcomes. Conclusions The hybrid typology proposed herein must be considered a construct still in evolution. Although traditional clinical effectiveness and implementation trials are likely to remain the most common approach to moving a clinical intervention through from efficacy research to public health impact, judicious use of the proposed hybrid designs could speed the translation of research findings into routine practice. PMID:22310560
Altaras, Robin; Nuwa, Anthony; Agaba, Bosco; Streat, Elizabeth; Tibenderana, James K.; Martin, Sandrine; Strachan, Clare E.
2016-01-01
Background Successful scale-up in the use of malaria rapid diagnostic tests (RDTs) requires that patients accept testing and treatment based on RDT results and that healthcare providers treat according to test results. Patient-provider communication is a key component of quality care, and leads to improved patient satisfaction, higher adherence to treatment and better health outcomes. Voiced or perceived patient expectations are also known to influence treatment decision-making among healthcare providers. While there has been a growth in literature on provider practices around rapid testing for malaria, there has been little analysis of inter-personal communication around the testing process. We investigated how healthcare providers and patients interact and engage throughout the diagnostic and treatment process, and how the testing service is experienced by patients in practice. Methods This research was conducted alongside a larger study which explored determinants of provider treatment decision-making following negative RDT results in a rural district (Kibaale) in mid-western Uganda, ten months after RDT introduction. Fifty-five patients presenting with fever were observed during routine outpatient visits at 12 low-level public health facilities. Observation captured communication practices relating to test purpose, results, diagnosis and treatment. All observed patients or caregivers were immediately followed up with in-depth interview. Analysis followed the ‘framework’ approach. A summative approach was also used to analyse observation data. Results Providers failed to consistently communicate the reasons for carrying out the test, and particularly to RDT-negative patients, a diagnostic outcome or the meaning of test results, also leading to confusion over what the test can detect. Patients appeared to value testing, but were frustrated by the lack of communication on outcomes. RDT-negative patients were dissatisfied by the absence of information on an alternative diagnosis and expressed uncertainty around adequacy of proposed treatment. Conclusions Poor provider communication practices around the testing process, as well as limited inter-personal exchange between providers and patients, impacted on patients’ perceptions of their proposed treatment. Patients have a right to health information and may be more likely to accept and adhere to treatment when they understand their diagnosis and treatment rationale in relation to their perceived health needs and visit expectations. PMID:27494507
2012-05-31
plasmid and P . falciparum plasmid. The assay was 100% (17/17) concordant in testing using a diverse panel ofPiasmodium species and strains prepared...AFMSA O&M FY10 ‘Plasmodium Project’, existing Plasmodium genus, P . falciparum , and P . vivax TaqMan assays were proposed for transfer to the RAPID...using P . vivax plasmid and P . falciparum plasmid. The assay was 100% (17/17) concordant in testing using a diverse panel of Plasmodium species and
NASA Astrophysics Data System (ADS)
Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth
2013-03-01
Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.
Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P
2018-01-01
Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.
Díaz-Orueta, Unai; Blanco-Campal, Alberto; Burke, Teresa
2018-05-01
ABSTRACTBackground:A detailed neuropsychological assessment plays an important role in the diagnostic process of Mild Cognitive Impairment (MCI). However, available brief cognitive screening tests for this clinical population are administered and interpreted based mainly, or exclusively, on total achievement scores. This score-based approach can lead to erroneous clinical interpretations unless we also pay attention to the test taking behavior or to the type of errors committed during test performance. The goal of the current study is to perform a rapid review of the literature regarding cognitive screening tools for dementia in primary and secondary care; this will include revisiting previously published systematic reviews on screening tools for dementia, extensive database search, and analysis of individual references cited in selected studies. A subset of representative screening tools for dementia was identified that covers as many cognitive functions as possible. How these screening tools overlap with each other (in terms of the cognitive domains being measured and the method used to assess them) was examined and a series of process-based approach (PBA) modifications for these overlapping features was proposed, so that the changes recommended in relation to one particular cognitive task could be extrapolated to other screening tools. It is expected that future versions of cognitive screening tests, modified using a PBA, will highlight the benefits of attending to qualitative features of test performance when trying to identify subtle features suggestive of MCI and/or dementia.
Tseng, Shao-Chin; Yu, Chen-Chieh; Wan, Dehui; Chen, Hsuen-Li; Wang, Lon Alex; Wu, Ming-Chung; Su, Wei-Fang; Han, Hsieh-Cheng; Chen, Li-Chyong
2012-06-05
Convenient, rapid, and accurate detection of chemical and biomolecules would be a great benefit to medical, pharmaceutical, and environmental sciences. Many chemical and biosensors based on metal nanoparticles (NPs) have been developed. However, as a result of the inconvenience and complexity of most of the current preparation techniques, surface plasmon-based test papers are not as common as, for example, litmus paper, which finds daily use. In this paper, we propose a convenient and practical technique, based on the photothermal effect, to fabricate the plasmonic test paper. This technique is superior to other reported methods for its rapid fabrication time (a few seconds), large-area throughput, selectivity in the positioning of the NPs, and the capability of preparing NP arrays in high density on various paper substrates. In addition to their low cost, portability, flexibility, and biodegradability, plasmonic test paper can be burned after detecting contagious biomolecules, making them safe and eco-friendly.
A new in vitro method for testing plant metabolism in mutagenicity studies.
Benigni, R; Bignami, M; Camoni, I; Carere, A; Conti, G; Iachetta, R; Morpurgo, G; Ortali, V A
1979-09-01
A rapid method was proposed to detect whether a harmless agricultural chemical can be converted into a mutagenic one by plant metabolism. The method is based on the use of Nicotiana alata cell cultures. Results obtained with five pesticides (atrazine, dichlorvos, tetrachlorvinphos, Kelevan, and maleic hydrazide) suggest that the proposed method simulates the metabolism of the whole plant. This procedure was also successfully applied to the genetic system of Aspergillus nidulans. One pesticide, atrazine, induced mutations and somatic segregation only after metabolism during cocultivation with N. alata cells.
NASA Astrophysics Data System (ADS)
Seki, Hirokazu; Hata, Naoki; Koyasu, Yuichi; Hori, Yoichi
Aged people and disabled people who have difficulty in walking are increasing. As one of mobility support, significance of power assisted wheelchair which assists driving force using electric motors and spreads their living areas has been enhanced. However, the increased driving force often causes a dangerous overturn of wheelchair. In this paper, control method to prevent power assisted wheelchair from overturning is proposed. It is found the front wheels rising is caused by magnitude and rapid increase of assisted torque. Therefore, feedforward control method to limit the assisted torque by tuning its magnitude or time constant is proposed. In order to emphasize safety and feeling of security, these methods make the front wheels no rise. The effectiveness of the proposed method is verified by the practical experiments and field test based performance evaluation using many trial subjects.
Bendas, Ehab Rasmy; Basalious, Emad B
2016-01-01
Our objective was to develop novel vagina retentive cream suppositories (VRCS) of progesterone having rapid disintegration and good vaginal retention. VRCS of progesterone were prepared using oil in water (o/w) emulsion of mineral oil or theobroma oil in hard fat and compared with conventional vaginal suppositories (CVS) prepared by hard fat. VRCS formulations were tested for content uniformity, disintegration, melting range, in vitro release and stability studies. The most stable formulation (VRCS I) was subjected to scaling-up manufacturing and patients' satisfaction test. The rapid disintegration, good retentive properties are applicable through the inclusion of emulsified theobroma oil rather than hydrophilic surfactant into the hard fat bases. The release profile of progesterone from VRCS I showed a biphasic pattern due to the formation of progesterone reservoir in the emulsified theobroma oil. All volunteers involved in patients' satisfaction test showed high satisfactory response to the tested formulation (VRCS). The in vivo pharmacokinetic study suggests that VRCS of progesterone provided higher rate and extent of absorption compared to hard fat based suppositories. Our results proposed that emulsified theobroma oil could be promising to solve the problems of poor patients' satisfaction and variability of drug absorption associated with hard fat suppositories.
Peker, Musa; Şen, Baha; Gürüler, Hüseyin
2015-02-01
The effect of anesthesia on the patient is referred to as depth of anesthesia. Rapid classification of appropriate depth level of anesthesia is a matter of great importance in surgical operations. Similarly, accelerating classification algorithms is important for the rapid solution of problems in the field of biomedical signal processing. However numerous, time-consuming mathematical operations are required when training and testing stages of the classification algorithms, especially in neural networks. In this study, to accelerate the process, parallel programming and computing platform (Nvidia CUDA) facilitates dramatic increases in computing performance by harnessing the power of the graphics processing unit (GPU) was utilized. The system was employed to detect anesthetic depth level on related electroencephalogram (EEG) data set. This dataset is rather complex and large. Moreover, the achieving more anesthetic levels with rapid response is critical in anesthesia. The proposed parallelization method yielded high accurate classification results in a faster time.
A Model of Rapid Radicalization Behavior Using Agent-Based Modeling and Quorum Sensing
NASA Technical Reports Server (NTRS)
Schwartz, Noah; Drucker, Nick; Campbell, Kenyth
2012-01-01
Understanding the dynamics of radicalization, especially rapid radicalization, has become increasingly important to US policy in the past several years. Traditionally, radicalization is considered a slow process, but recent social and political events demonstrate that the process can occur quickly. Examining this rapid process, in real time, is impossible. However, recreating an event using modeling and simulation (M&S) allows researchers to study some of the complex dynamics associated with rapid radicalization. We propose to adapt the biological mechanism of quorum sensing as a tool to explore, or possibly explain, rapid radicalization. Due to the complex nature of quorum sensing, M&S allows us to examine events that we could not otherwise examine in real time. For this study, we employ Agent Based Modeling (ABM), an M&S paradigm suited to modeling group behavior. The result of this study was the successful creation of rapid radicalization using quorum sensing. The Battle of Mogadishu was the inspiration for this model and provided the testing conditions used to explore quorum sensing and the ideas behind rapid radicalization. The final product has wider applicability however, using quorum sensing as a possible tool for examining other catalytic rapid radicalization events.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-29
... Proposed Information Collection to OMB; Evaluation of the Rapid Re-Housing for Homeless Families... public comments on the subject proposal. The FY 2008 budget for the U.S. Department of Housing and Urban Development (H.R. 2764) included a $25 million set-aside to implement a Rapid Re-housing for Families...
NASA Astrophysics Data System (ADS)
Xu, Chuanpei; Niu, Junhao; Ling, Jing; Wang, Suyan
2018-03-01
In this paper, we present a parallel test strategy for bandwidth division multiplexing under the test access mechanism bandwidth constraint. The Pareto solution set is combined with a cloud evolutionary algorithm to optimize the test time and power consumption of a three-dimensional network-on-chip (3D NoC). In the proposed method, all individuals in the population are sorted in non-dominated order and allocated to the corresponding level. Individuals with extreme and similar characteristics are then removed. To increase the diversity of the population and prevent the algorithm from becoming stuck around local optima, a competition strategy is designed for the individuals. Finally, we adopt an elite reservation strategy and update the individuals according to the cloud model. Experimental results show that the proposed algorithm converges to the optimal Pareto solution set rapidly and accurately. This not only obtains the shortest test time, but also optimizes the power consumption of the 3D NoC.
Schedler, Kathrin; Assadian, Ojan; Brautferger, Uta; Müller, Gerald; Koburger, Torsten; Classen, Simon; Kramer, Axel
2017-02-13
Currently, there is no agreed standard for exploring the antimicrobial activity of wound antiseptics in a phase 2/ step 2 test protocol. In the present study, a standardised in-vitro test is proposed, which allows to test potential antiseptics in a more realistically simulation of conditions found in wounds as in a suspension test. Furthermore, factors potentially influencing test results such as type of materials used as test carrier or various compositions of organic soil challenge were investigated in detail. This proposed phase 2/ step 2 test method was modified on basis of the EN 14561 by drying the microbial test suspension on a metal carrier for 1 h, overlaying the test wound antiseptic, washing-off, neutralization, and dispersion at serial dilutions at the end of the required exposure time yielded reproducible, consistent test results. The difference between the rapid onset of the antiseptic effect of PVP-I and the delayed onset especially of polihexanide was apparent. Among surface-active antimicrobial compounds, octenidine was more effective than chlorhexidine digluconate and polihexanide, with some differences depending on the test organisms. However, octenidine and PVP-I were approximately equivalent in efficiency and microbial spectrum, while polihexanide required longer exposure times or higher concentrations for a comparable antimicrobial efficacy. Overall, this method allowed testing and comparing differ liquid and gel based antimicrobial compounds in a standardised setting.
NASA Technical Reports Server (NTRS)
Phillips, Dave; Haas, William; Barth, Tim; Benjamin, Perakath; Graul, Michael; Bagatourova, Olga
2005-01-01
Range Process Simulation Tool (RPST) is a computer program that assists managers in rapidly predicting and quantitatively assessing the operational effects of proposed technological additions to, and/or upgrades of, complex facilities and engineering systems such as the Eastern Test Range. Originally designed for application to space transportation systems, RPST is also suitable for assessing effects of proposed changes in industrial facilities and large organizations. RPST follows a model-based approach that includes finite-capacity schedule analysis and discrete-event process simulation. A component-based, scalable, open architecture makes RPST easily and rapidly tailorable for diverse applications. Specific RPST functions include: (1) definition of analysis objectives and performance metrics; (2) selection of process templates from a processtemplate library; (3) configuration of process models for detailed simulation and schedule analysis; (4) design of operations- analysis experiments; (5) schedule and simulation-based process analysis; and (6) optimization of performance by use of genetic algorithms and simulated annealing. The main benefits afforded by RPST are provision of information that can be used to reduce costs of operation and maintenance, and the capability for affordable, accurate, and reliable prediction and exploration of the consequences of many alternative proposed decisions.
Berthod, Delphine; Rochat, Jacynthe; Voumard, Rachel; Rochat, Laurence; Genton, Blaise; D'Acremont, Valérie
2017-10-28
The WHO recommends that all suspect malaria cases be tested before receiving treatment. Rapid diagnostic tests (RDT) for malaria can be performed reliably by community health workers with no formal medical background and thus, RDTs could also be provided to travellers for self-diagnosis during visits to endemic regions. RDTs were proposed during pre-travel consultations to pre-defined categories of travellers. A training run on their own blood was performed and, if carried out correctly, the traveller was given a written procedure on how to perform the test and act on its result. The travellers were then proposed to buy a malaria RDT kit and were interviewed upon their return. From February 2012 to February 2017, 744 travellers were proposed RDTs and 692 performed the training run (one could not complete it due to a hand tremor). Among the 691 subjects included, 69% travelled to moderate- or low-risk areas of malaria, 18% to high-risk areas and 13% to mixed-risk areas. The two most frequent categories of travellers to whom RDTs were proposed were long-term travellers (69%) and those travelling to remote areas (57%). 543 travellers (79%) were interviewed upon return. During their trip, 17% (91/543) had a medical problem with fever and 12% (65/543) without fever. Among 91 febrile patients, 57% (52/91) performed an RDT, 22% (20/91) consulted immediately without using the test, and 21% (19/91) did neither. Four RDTs (4/52; 8%) were positive: 2 in low-risk and 2 in high-risk areas (0.7% attack rate of self-documented malaria). Two travellers could not perform the test correctly and attended a facility or took standby emergency treatment. Four travellers with negative results repeated the test after 24 h; all were still negative. Carrying RDTs made travellers feel more secure, especially when travelling with children. 1/6 travellers experienced fever and 4/5 of those reacted appropriately: more than half used RDTs and a quarter consulted immediately. Four travellers (including 2 from low-risk areas) diagnosed themselves with malaria and self-treated successfully. This strategy allows prompt treatment for malaria in high-risk groups and may avoid over-diagnosis (and subsequent inappropriate treatment) of malaria on-site.
Curran, Geoffrey M; Bauer, Mark; Mittman, Brian; Pyne, Jeffrey M; Stetler, Cheryl
2012-03-01
This study proposes methods for blending design components of clinical effectiveness and implementation research. Such blending can provide benefits over pursuing these lines of research independently; for example, more rapid translational gains, more effective implementation strategies, and more useful information for decision makers. This study proposes a "hybrid effectiveness-implementation" typology, describes a rationale for their use, outlines the design decisions that must be faced, and provides several real-world examples. An effectiveness-implementation hybrid design is one that takes a dual focus a priori in assessing clinical effectiveness and implementation. We propose 3 hybrid types: (1) testing effects of a clinical intervention on relevant outcomes while observing and gathering information on implementation; (2) dual testing of clinical and implementation interventions/strategies; and (3) testing of an implementation strategy while observing and gathering information on the clinical intervention's impact on relevant outcomes. The hybrid typology proposed herein must be considered a construct still in evolution. Although traditional clinical effectiveness and implementation trials are likely to remain the most common approach to moving a clinical intervention through from efficacy research to public health impact, judicious use of the proposed hybrid designs could speed the translation of research findings into routine practice.
Collins, S; Stevenson, D; Walker, J; Bennett, A
2017-06-01
To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.
Measurement of Vehicle-Bridge-Interaction force using dynamic tire pressure monitoring
NASA Astrophysics Data System (ADS)
Chen, Zhao; Xie, Zhipeng; Zhang, Jian
2018-05-01
The Vehicle-Bridge-Interaction (VBI) force, i.e., the normal contact force of a tire, is a key component in the VBI mechanism. The VBI force measurement can facilitate experimental studies of the VBI as well as input-output bridge structural identification. This paper introduces an innovative method for calculating the interaction force by using dynamic tire pressure monitoring. The core idea of the proposed method combines the ideal gas law and a basic force model to build a relationship between the tire pressure and the VBI force. Then, unknown model parameters are identified by the Extended Kalman Filter using calibration data. A signal filter based on the wavelet analysis is applied to preprocess the effect that the tire rotation has on the pressure data. Two laboratory tests were conducted to check the proposed method's validity. The effects of different road irregularities, loads and forward velocities were studied. Under the current experiment setting, the proposed method was robust to different road irregularities, and the increase in load and velocity benefited the performance of the proposed method. A high-speed test further supported the use of this method in rapid bridge tests. Limitations of the derived theories and experiment were also discussed.
NASA Technical Reports Server (NTRS)
Morgan, E. L.; Young, R. C.; Smith, M. D.; Eagleson, K. W.
1986-01-01
The objective of this study was to evaluate proposed design characteristics and applications of automated biomonitoring devices for real-time toxicity detection in water quality control on-board permanent space stations. Simulated tests in downlinking transmissions of automated biomonitoring data to Earth-receiving stations were simulated using satellite data transmissions from remote Earth-based stations.
NASA Astrophysics Data System (ADS)
Al Okab, Riyad Ahmed
2013-02-01
Green analytical methods using Cisapride (CPE) as green analytical reagent was investigated in this work. Rapid, simple, and sensitive spectrophotometric methods for the determination of bromate in water sample, bread and flour additives were developed. The proposed methods based on the oxidative coupling between phenoxazine and Cisapride in the presence of bromate to form red colored product with max at 520 nm. Phenoxazine and Cisapride and its reaction products were found to be environmentally friendly under the optimum experimental condition. The method obeys beers law in concentration range 0.11-4.00 g ml-1 and molar absorptivity 1.41 × 104 L mol-1 cm-1. All variables have been optimized and the presented reaction sequences were applied to the analysis of bromate in water, bread and flour additive samples. The performance of these method was evaluated in terms of Student's t-test and variance ratio F-test to find out the significance of proposed methods over the reference method. The combination of pharmaceutical drugs reagents with low concentration create some unique green chemical analyses.
Rapid and low-cost hot-embossing of polycaprolactone microfluidic devices
NASA Astrophysics Data System (ADS)
Fan, Yiqiang; Liu, Shicheng; He, Jianyun; Gao, Kexin; Zhang, Yajun
2018-01-01
Polycaprolactone (PCL) is a low-cost biocompatible and biodegradable material which is highly suitable for the short-live applications like microfluidics in the biological and medical field. In this study, a rapid and low-cost microfabrication technique for PCL-based microfluidic devices is proposed, the SU-8 mold fabricated on the silicon substrate was used for the hot-embossing of microstructures on PCL. Since PCL after the molding process is optically non-transparent, to improve the visibility of the fluid in the microfluidic device and enclosing the microchannel, a transparency adhesive film which originally used for the sealing of PCR well-plate is used for the sealing of the microchannels embossed on PCL substrate. The profile of the fabricated microchannels was carefully characterized, the bonding strength is tested and several PCL-based microfluidic devices were also fabricated and tested for demonstration.
Spacewire router IP-core with priority adaptive routing
NASA Astrophysics Data System (ADS)
Shakhmatov, A. V.; Chekmarev, S. A.; Vergasov, M. Y.; Khanov, V. Kh
2015-10-01
Design of modern spacecraft focuses on using network principles of interaction on-board equipment, in particular in network SpaceWire. Routers are an integral part of most SpaceWire networks. The paper presents an adaptive routing algorithm with a prioritization, allowing more flexibility to manage the routing process. This algorithm is designed to transmit SpaceWire packets over a redundant network. Also a method is proposed for rapid restoration of working capacity after power by saving the routing table and the router configuration in an external non-volatile memory. The proposed solutions used to create IP-core router, and then tested in the FPGA device. The results illustrate the realizability and rationality of the proposed solutions.
A sequential test for assessing observed agreement between raters.
Bersimis, Sotiris; Sachlas, Athanasios; Chakraborti, Subha
2018-01-01
Assessing the agreement between two or more raters is an important topic in medical practice. Existing techniques, which deal with categorical data, are based on contingency tables. This is often an obstacle in practice as we have to wait for a long time to collect the appropriate sample size of subjects to construct the contingency table. In this paper, we introduce a nonparametric sequential test for assessing agreement, which can be applied as data accrues, does not require a contingency table, facilitating a rapid assessment of the agreement. The proposed test is based on the cumulative sum of the number of disagreements between the two raters and a suitable statistic representing the waiting time until the cumulative sum exceeds a predefined threshold. We treat the cases of testing two raters' agreement with respect to one or more characteristics and using two or more classification categories, the case where the two raters extremely disagree, and finally the case of testing more than two raters' agreement. The numerical investigation shows that the proposed test has excellent performance. Compared to the existing methods, the proposed method appears to require significantly smaller sample size with equivalent power. Moreover, the proposed method is easily generalizable and brings the problem of assessing the agreement between two or more raters and one or more characteristics under a unified framework, thus providing an easy to use tool to medical practitioners. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi
2013-01-01
The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.
Rapid identification of Corynebacterium vaginale in non-purulent vaginitis.
Wells, J I; Goei, S H
1981-01-01
A simple set of tests is proposed to give excellent probability for the identification of Corynebacterium vaginale from clinical material. Using these tests, 380 C vaginale were isolated from genital tract specimens from 1402 patients. Of these isolates 70 were from symptomatic patients. These 70 isolates were subjected to a further set of tests to confirm their identity. The advantage of these primary tests is that they can be completed on the day of isolation of the organism. Of these 70 isolates 66 were confirmed as C vaginale thus giving the primary set of tests a 94% rate of accurate identification. However this rate may be increased beyond 97% by the promotion of one of the key secondary tests to the primary set. PMID:7024317
Determinants of customer satisfaction with hospitals: a managerial model.
Andaleeb, S S
1998-01-01
States that rapid changes in the environment have exerted significant pressures on hospitals to incorporate patient satisfaction in their strategic stance and quest for market share and long-term viability. This study proposes and tests a five-factor model that explains considerable variation in customer satisfaction with hospitals. These factors include communication with patients, competence of the staff, their demeanour, quality of the facilities, and perceived costs; they also represent strategic concepts that managers can address in their bid to remain competitive. A probability sample was selected and a multiple regression model used to test the hypotheses. The results indicate that all five variables were significant in the model and explained 62 per cent of the variation in the dependent variable. Managerial implications of the proposed model are discussed.
Chen, Yanni; Guo, Lingling; Liu, Liqiang; Song, Shanshan; Kuang, Hua; Xu, Chuanlai
2017-09-20
Group-specific monoclonal antibodies (Mabs) with selectivity for 27 sulfonamides were developed based on new combinations of immunogen and coating antigen. The Mab was able to recognize 27 sulfonamides with 50% inhibition concentration (IC 50 ) values ranging from 0.15 to 15.38 μg/L. In particular, the IC 50 values for five sulfonamides (sulfamethazine, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxine, and sulfamethoxazole) were 0.51, 0.15, 0.56, 0.54, and 2.14 μg/L, respectively. On the basis of the Mab, an immunochromatographic lateral flow strip test was established for rapid screening of sulfonamides in honey samples. The visual limit of detection of the strip test for most sulfonamides in spiked honey samples was below 10 μg/kg, satisfying the requirements of authorities. Positive honey and pork liver samples, which had been confirmed by high-performance liquid chromatography/mass spectrometry, were used to validate the reliability of the proposed strip test. The immunochromatographic lateral flow strip test provides a rapid and convenient method for fast screening of sulfonamides in honey samples.
Brault, F; Waton, J; Poreaux, C; Schmutz, J-L; Barbaud, A
2017-11-01
The rate of hypersensitivity reactions to platinum salts (PS) and taxanes (TX) is on the increase. The aim of our study was to show the value of skin testing and efficacy of rapid drug desensitization. This was a retrospective study conducted between January 2007 and February 2016 in patients consulting for immediate or delayed hypersensitivity to PS and TX. Skin prick tests (pT) and intradermal reaction tests (IDR) were performed according to the ENDA/EAACI recommendations. We used a 12-step desensitization protocol for rapid drug desensitization. Among the 99 patients included (30 men, 69 women, age 60.4) PS were suspected in 86 cases and taxanes in 13 cases. Skin tests were positive in 25 patients (7 pT, 18 IDR), 23 for platinum salts and 2 for taxanes. Rapid drug desensitization was proposed in 50 patients and performed in 33 (30 PS and 3 TX), proved effective in 29 patients, with protocol adaptation being necessary in 7 cases, and was ineffective in 4 patients. The skin tests for the latter 4 patients were positive. Seventy-five percent of patients with positive skin tests to oxaliplatin presented hypersensitivity reactions during desensitization, i.e. twice as many as patients having negative skin tests. Two percent of patient for PS and 7% for TX had cross reactivity. This French study confirms the efficacy of the 12-step protocol that allows patients to receive chemotherapy after hypersensitivity reaction. Skin test permits the detection of cross-reactions but their practice must be considered based on the patient's history. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw; Robert Vatalaro
2005-01-01
This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...
Post-tensioning tendon force loss detection using low power pulsed eddy current measurement
NASA Astrophysics Data System (ADS)
Kim, Ji-Min; Lee, Jun; Sohn, Hoon
2018-04-01
In the field of bridge engineering, pre-fabrication of a bridge member and its construction in site have been issued and studied, which achieves improved quality and rapid construction. For integration of those pre-fabricated segments into a structural member (i.e., a concrete slab, girder and pier), post-tensioning (PT) technique is adopted utilizing a high-strength steel tendon, and an effective investigation of the remaining PT tendon force is essential to assure an overall structural integrity. This study proposes a pulsed eddy current based tendon force loss detection system. A compact eddy current sensor is designed to be installed on the surface of an anchor holding a steel PT tendon. The intensity of the induced eddy current varies with PT tendon force alteration due to the magnetostriction effect of a ferromagnetic material. The advantages of the proposed system are as follows: (1) low power consumption, (2) rapid inspection, and (3) simple installation. Its performance was validated experimentally in a full-scale lab test of a 3.3-m long, 15.2-mm diameter mono-tendon that was tensioned using a universal testing machine. Tendon force was controlled from 20 to 180 kN with 20 kN interval, and eddy current responses were measured and analyzed at each force condition. The proposed damage index and the amount of force loss of PT tendon were monotonically related, and an excessive loss as much as 30 % of an initially-introduced tendon force was successfully predicted.
NASA Astrophysics Data System (ADS)
Hirano, Taichi; Sakai, Keiji
2017-07-01
Viscoelasticity is a unique characteristic of soft materials and describes its dynamic response to mechanical stimulations. A creep test is an experimental method for measuring the strain ratio/rate against an applied stress, thereby assessing the viscoelasticity of the materials. We propose two advanced experimental systems suitable for the creep test, adopting our original electromagnetically spinning (EMS) technique. This technique can apply a constant torque by a noncontact mechanism, thereby allowing more sensitive and rapid measurements. The viscosity and elasticity of a semidilute wormlike micellar solution were determined using two setups, and the consistency between the results was assessed.
NASA Technical Reports Server (NTRS)
Dietz, J. B.
1976-01-01
A flash evaporator heat rejection system representative of that proposed for the space shuttle orbiter underwent extensive system testing at the NASA Johnson Space Center (JSC) to determine its operational suitability and to establish system performance/operational characteristics for use in the shuttle system. During the tests the evaporator system demonstrated its suitability to meet the shuttle requirements by: (1) efficient operation with 90 to 95% water evaporation efficiency, (2) control of outlet temperature to 40 + or - 2 F for partial heat load operation, (3) stability of control system for rapid changes in Freon inlet temperature, and (4) repeated dormant-to-active device operation without any startup procedures.
Rapid Detection of Positive Selection in Genes and Genomes Through Variation Clusters
Wagner, Andreas
2007-01-01
Positive selection in genes and genomes can point to the evolutionary basis for differences among species and among races within a species. The detection of positive selection can also help identify functionally important protein regions and thus guide protein engineering. Many existing tests for positive selection are excessively conservative, vulnerable to artifacts caused by demographic population history, or computationally very intensive. I here propose a simple and rapid test that is complementary to existing tests and that overcomes some of these problems. It relies on the null hypothesis that neutrally evolving DNA regions should show a Poisson distribution of nucleotide substitutions. The test detects significant deviations from this expectation in the form of variation clusters, highly localized groups of amino acid changes in a coding region. In applying this test to several thousand human–chimpanzee gene orthologs, I show that such variation clusters are not generally caused by relaxed selection. They occur in well-defined domains of a protein's tertiary structure and show a large excess of amino acid replacement over silent substitutions. I also identify multiple new human–chimpanzee orthologs subject to positive selection, among them genes that are involved in reproductive functions, immune defense, and the nervous system. PMID:17603100
A Robust Image Watermarking in the Joint Time-Frequency Domain
NASA Astrophysics Data System (ADS)
Öztürk, Mahmut; Akan, Aydın; Çekiç, Yalçın
2010-12-01
With the rapid development of computers and internet applications, copyright protection of multimedia data has become an important problem. Watermarking techniques are proposed as a solution to copyright protection of digital media files. In this paper, a new, robust, and high-capacity watermarking method that is based on spatiofrequency (SF) representation is presented. We use the discrete evolutionary transform (DET) calculated by the Gabor expansion to represent an image in the joint SF domain. The watermark is embedded onto selected coefficients in the joint SF domain. Hence, by combining the advantages of spatial and spectral domain watermarking methods, a robust, invisible, secure, and high-capacity watermarking method is presented. A correlation-based detector is also proposed to detect and extract any possible watermarks on an image. The proposed watermarking method was tested on some commonly used test images under different signal processing attacks like additive noise, Wiener and Median filtering, JPEG compression, rotation, and cropping. Simulation results show that our method is robust against all of the attacks.
Noordin, Rahmah; Itoh, Makoto; Kimura, Eisaku; Abdul Rahman, Rohana; Ravindran, Balachandran; Mahmud, Rohela; Supali, Taniawati; Weerasooriya, Mirani
2007-01-01
In the global effort to eliminate lymphatic filariasis (LF), rapid field-applicable tests are useful tools that will allow on-site testing to be performed in remote places and the results to be obtained rapidly. Exclusive reliance on the few existing tests may jeopardize the progress of the LF elimination program, thus the introduction of other rapid tests would be useful to address this issue. Two new rapid immunochromatographic IgG4 cassette tests have been produced, namely WB rapid and panLF rapid, for detection of bancroftian filariasis and all three species of lymphatic filaria respectively. WB rapid was developed using BmSXP recombinant antigen, while PanLF rapid was developed using BmR1 and BmSXP recombinant antigens. A total of 165 WB rapid and 276 panLF rapid tests respectively were evaluated at USM and the rest were couriered to another university in Malaysia (98 WB rapid, 129 panLF rapid) and to universities in Indonesia (56 WB rapid, 62 panLF rapid), Japan (152 of each test) and India (18 of each test) where each of the tests underwent independent evaluations in a blinded manner. The average sensitivities of WB rapid and panLF rapid were found to be 97.6% (94%–100%) and 96.5% (94%–100%) respectively; while their average specificities were both 99.6% (99%–100%). Thus this study demonstrated that both the IgG4 rapid tests were highly sensitive and specific, and would be useful additional tests to facilitate the global drive to eliminate this disease. PMID:17961262
Zhang, Yong-Feng; Chiang, Hsiao-Dong
2017-09-01
A novel three-stage methodology, termed the "consensus-based particle swarm optimization (PSO)-assisted Trust-Tech methodology," to find global optimal solutions for nonlinear optimization problems is presented. It is composed of Trust-Tech methods, consensus-based PSO, and local optimization methods that are integrated to compute a set of high-quality local optimal solutions that can contain the global optimal solution. The proposed methodology compares very favorably with several recently developed PSO algorithms based on a set of small-dimension benchmark optimization problems and 20 large-dimension test functions from the CEC 2010 competition. The analytical basis for the proposed methodology is also provided. Experimental results demonstrate that the proposed methodology can rapidly obtain high-quality optimal solutions that can contain the global optimal solution. The scalability of the proposed methodology is promising.
Wu, Chia-Chang
2017-08-15
We propose a simple, rapid analytical method for determination of 89 pesticides in Oolong tea by GC/MS/MS. Samples were extracted via QuEChERS. The limits of detection and quantification range of the 89 pesticides were 1-25μgL -1 and 10-50μgL -1 , respectively. Good separation was attained in less than 36min. A wide linear range of 1-250μgL -1 was observed with r 2 values from 0.9955 to 0.9998. Pesticide-free tea powder spiked at 50 and 100μgL -1 . Recovery ranges of the 86 (50μgL -1 ) and 83 (100μgL -1 ) pesticides were from 60% to 120%. Relative standard deviations were less than 20%. The laboratory proficiency test (FAPAS, 2014) shows satisfactory (|z|<2) z-score values. The proposed monitoring technique rapidly and efficiently screens, multiple pesticides in Oolong tea. Copyright © 2017 Elsevier Ltd. All rights reserved.
El-Yazbi, Amira F
2017-07-01
Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virus infection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with P-value > 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.
Zenebon, Odair; Sakuma, Alice M; Dovidauskas, Sergio; Okada, Isaura A; de, MaioFrancaD; Lichtig, Jaim
2002-01-01
A mixture of 50% H2O2-H2SO4 (3 + 1, v/v) was used for decomposition of food in open vessels at 80 degrees C. The treatment allowed rapid total mercury determination by flow injection cold vapor atomic absorption spectrometry. Cabbage, potatoes, peanuts paste, hazelnuts paste, oats, tomatoes and their derivatives, oysters, shrimps, prawns, shellfish, marine algae, and many kinds of fish were analyzed by the proposed methodology with a limit of quantitation of 0.86 +/- 0.08 microg/L mercury in the final solution. Reference materials tested also gave excellent recovery.
Jang, Hyunwook; Ahmed, Syed Rahin; Neethirajan, Suresh
2017-01-01
Enzyme-linked immunosorbent assay (ELISA) is a popular assay technique for the detection and quantification of various biological substances due its high sensitivity and specificity. More often, it requires large and expensive laboratory instruments, which makes it difficult to conduct when the tests must be performed quickly at the point-of-care (POC). To increase portability and ease of use, we propose a portable diagnostic system based on a Raspberry Pi imaging sensor for the rapid detection of progesterone in milk samples. We designed, assembled, and tested a standalone portable diagnostic reader and validated it for progesterone detection against a standard ELISA assay using a commercial plate reader. The portable POC device yielded consistent results, regardless of differences in the cameras and flashlights between various smartphone devices. An Android application was built to provide front-end access to users, control the diagnostic reader, and display and store the progesterone measurement on the smartphone. The diagnostic reader takes images of the samples, reads the pixel values, processes the results, and presents the results on the handheld device. The proposed POC reader can perform to superior levels of performance as a plate reader, while adding the desirable qualities of portability and ease of use. PMID:28489036
Jang, Hyunwook; Ahmed, Syed Rahin; Neethirajan, Suresh
2017-05-10
Enzyme-linked immunosorbent assay (ELISA) is a popular assay technique for the detection and quantification of various biological substances due its high sensitivity and specificity. More often, it requires large and expensive laboratory instruments, which makes it difficult to conduct when the tests must be performed quickly at the point-of-care (POC). To increase portability and ease of use, we propose a portable diagnostic system based on a Raspberry Pi imaging sensor for the rapid detection of progesterone in milk samples. We designed, assembled, and tested a standalone portable diagnostic reader and validated it for progesterone detection against a standard ELISA assay using a commercial plate reader. The portable POC device yielded consistent results, regardless of differences in the cameras and flashlights between various smartphone devices. An Android application was built to provide front-end access to users, control the diagnostic reader, and display and store the progesterone measurement on the smartphone. The diagnostic reader takes images of the samples, reads the pixel values, processes the results, and presents the results on the handheld device. The proposed POC reader can perform to superior levels of performance as a plate reader, while adding the desirable qualities of portability and ease of use.
Lussiana, Cristina
2016-09-01
The idea of a private sector subsidy programme of artemisinin-based combination therapies (ACTs) was first proposed in 2004. Since then, several countries around the world have hosted pilot projects or programmes on subsidized ACTs and/or the Affordable Medicines Facility-malaria programme (AMFm). Overall the private sector subsidy programmes of ACTs have been effective in increasing availability of ACTs in the private sector and driving down average prices but struggled to crowd out antimalarial monotherapies. The results obtained from this ambitious strategy should inform policy makers in the designing of future interventions aimed to control malaria morbidity and mortality. Among the interventions recently proposed, a subsidy of rapid diagnostic tests (RDTs) in the private sector has been recommended by governments and international donors to cope with over-treatment with ACTs and to delay the emergence of resistance to artemisinin. In order to improve the cost-effectiveness of co-paid RDTs, we should build on the lessons we learned from almost 10 years of private sector subsidy programmes of ACTs in malaria-endemic countries. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa
Matsumoto, Yoshimi; Grushnikov, Andrey; Kikuchi, Kazuma; Noji, Hiroyuki; Yamaguchi, Akihito; Yagi, Yasushi
2016-01-01
The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM) device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller–Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation. PMID:26872134
Pinot, C; Deredjian, A; Nazaret, S; Brothier, E; Cournoyer, B; Segonds, C; Favre-Bonté, S
2011-11-01
Aim of the study is to identify accurately Stenotrophomonas maltophilia isolates recovered from environmental and clinical samples. Recovery of Sten. maltophilia-like isolates from soil samples using the vancomycin, imipenem, amphotericin B (VIA) selective agar medium enabled distinction of various morphotype colonies. A set of soil and clinical isolates was tested for species identification using different methods. 16S rDNA analyses showed the dark green with a blue halo morphotype to be typical Sten. maltophilia strains. The API-20NE, Vitek-2 and Biolog phenotypic analyses typically used for the identification of clinical isolates did not perform well on these soil isolates. The species-specific PCR screening targeting Sten. maltophilia 23S rDNA and the multiplex smeD/ggpS PCR, differentiating Sten. maltophilia from Stenotrophomonas rhizophila, were tested for improvement of these identification schemes. The latter multiplex PCR identified all isolates tested in this study, whatever be their origin. Isolation on VIA medium and confirmation of Sten. maltophilia species membership by smeD PCR is proposed to identify environmental and clinical isolates of Sten. maltophilia. The proposed approach enables isolation and identification of Sten. maltophilia from different environments in an easy and rapid way. This approach will be useful to accurately manage studies on the abundance and distribution of Sten. maltophilia in hospital and nonhospital environments. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.
Novel railway-subgrade vibration monitoring technology using phase-sensitive OTDR
NASA Astrophysics Data System (ADS)
Wang, Zhaoyong; Lu, Bin; Zheng, Hanrong; Ye, Qing; Pan, Zhengqing; Cai, Haiwen; Qu, Ronghui; Fang, Zujie; Zhao, Howell
2017-04-01
High-speed railway is being developed rapidly; its safety, including infrastructure and train operation, is vital. This paper presents a railway-subgrade vibration monitoring scheme based on phase-sensitive OTDR for railway safety. The subgrade vibration is detected and rebuilt. Multi-dimension comprehensive analysis (MDCA) is proposed to identify the running train signals and illegal constructions along railway. To our best knowledge, it is the first time that a railway-subgrade vibration monitoring scheme is proposed. This scheme is proved effective by field tests for real-time train tracking and activities monitoring along railway. It provides a new passive distributed way for all-weather railway-subgrade vibration monitoring.
Lightweight composites for modular panelized construction
NASA Astrophysics Data System (ADS)
Vaidya, Amol S.
Rapid advances in construction materials technology have enabled civil engineers to achieve impressive gains in the safety, economy, and functionality of structures built to serve the common needs of society. Modular building systems is a fast-growing modern, form of construction gaining recognition for its increased efficiency and ability to apply modern technology to the needs of the market place. In the modular construction technique, a single structural panel can perform a number of functions such as providing thermal insulation, vibration damping, and structural strength. These multifunctional panels can be prefabricated in a manufacturing facility and then transferred to the construction site. A system that uses prefabricated panels for construction is called a "panelized construction system". This study focuses on the development of pre-cast, lightweight, multifunctional sandwich composite panels to be used for panelized construction. Two thermoplastic composite panels are proposed in this study, namely Composite Structural Insulated Panels (CSIPs) for exterior walls, floors and roofs, and Open Core Sandwich composite for multifunctional interior walls of a structure. Special manufacturing techniques are developed for manufacturing these panels. The structural behavior of these panels is analyzed based on various building design codes. Detailed descriptions of the design, cost analysis, manufacturing, finite element modeling and structural testing of these proposed panels are included in this study in the of form five peer-reviewed journal articles. The structural testing of the proposed panels involved in this study included flexural testing, axial compression testing, and low and high velocity impact testing. Based on the current study, the proposed CSIP wall and floor panels were found satisfactory, based on building design codes ASCE-7-05 and ACI-318-05. Joining techniques are proposed in this study for connecting the precast panels on the construction site. Keywords: Modular panelized construction, sandwich composites, composite structural insulated panels (CSIPs).
Schoenberg, Mike R; Rum, Ruba S
2017-11-01
Rapid, clear and efficient communication of neuropsychological results is essential to benefit patient care. Errors in communication are a lead cause of medical errors; nevertheless, there remains a lack of consistency in how neuropsychological scores are communicated. A major limitation in the communication of neuropsychological results is the inconsistent use of qualitative descriptors for standardized test scores and the use of vague terminology. PubMed search from 1 Jan 2007 to 1 Aug 2016 to identify guidelines or consensus statements for the description and reporting of qualitative terms to communicate neuropsychological test scores was conducted. The review found the use of confusing and overlapping terms to describe various ranges of percentile standardized test scores. In response, we propose a simplified set of qualitative descriptors for normalized test scores (Q-Simple) as a means to reduce errors in communicating test results. The Q-Simple qualitative terms are: 'very superior', 'superior', 'high average', 'average', 'low average', 'borderline' and 'abnormal/impaired'. A case example illustrates the proposed Q-Simple qualitative classification system to communicate neuropsychological results for neurosurgical planning. The Q-Simple qualitative descriptor system is aimed as a means to improve and standardize communication of standardized neuropsychological test scores. Research are needed to further evaluate neuropsychological communication errors. Conveying the clinical implications of neuropsychological results in a manner that minimizes risk for communication errors is a quintessential component of evidence-based practice. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Esper, Jaime; Andary, Jim; Oberright, John; So, Maria; Wegner, Peter; Hauser, Joe
2004-01-01
Modular, Reconfigurable, and Rapid-response (MR(sup 2)) space systems represent a paradigm shift in the way space assets of all sizes are designed, manufactured, integrated, tested, and flown. This paper will describe the MR(sup 2) paradigm in detail, and will include guidelines for its implementation. The Remote Sensing Advanced Technology microsatellite (RSAT) is a proposed flight system test-bed used for developing and implementing principles and best practices for MR(sup 2) spacecraft, and their supporting infrastructure. The initial goal of this test-bed application is to produce a lightweight (approx. 100 kg), production-minded, cost-effective, and scalable remote sensing micro-satellite capable of high performance and broad applicability. Such applications range from future distributed space systems, to sensor-webs, and rapid-response satellite systems. Architectures will be explored that strike a balance between modularity and integration while preserving the MR(sup 2) paradigm. Modularity versus integration has always been a point of contention when approaching a design: whereas one-of-a-kind missions may require close integration resulting in performance optimization, multiple and flexible application spacecraft benefit &om modularity, resulting in maximum flexibility. The process of building spacecraft rapidly (< 7 days), requires a concerted and methodical look at system integration and test processes and pitfalls. Although the concept of modularity is not new and was first developed in the 1970s by NASA's Goddard Space Flight Center (Multi-Mission Modular Spacecraft), it was never modernized and was eventually abandoned. Such concepts as the Rapid Spacecraft Development Office (RSDO) became the preferred method for acquiring satellites. Notwithstanding, over the past 30 years technology has advanced considerably, and the time is ripe to reconsider modularity in its own right, as enabler of R(sup 2), and as a key element of transformational systems. The MR2 architecture provides a competitive advantage over the old modular approach in its rapid response to market needs that are difficult to predict both from the perspectives of evolving technology, as well as mission and application requirements.
Rapid Cycling and Its Treatment
... may be rapid, ultra-rapid or ultradian cycling. Biological rhythm disturbances: This theory proposes that people with rapid cycling have daily biological rhythms that are out of sync with typical “ ...
A protocol to evaluate drug-related workplace impairment.
Reisfield, Gary M; Shults, Theodore; Demery, Jason; Dupont, Robert
2013-03-01
The dramatic increase in the use and abuse of prescription controlled substances, cannabis, and a rapidly evolving array of legal and illegal psychotropic drugs has led to a growing concern by employers about workplace impairment, incidents, and accidents. The Federal Workplace Drug Testing Programs, which serve as a template for most private sector programs, focus on a small group of illicit drugs, but disregard the wider spectrum of legal and illegal psychotropic drugs and prescription controlled substances. We propose a protocol for the evaluation of workplace impairment, based on comprehensive drug and alcohol testing at the time of suspected impairment, followed expeditiously by a comprehensive physician evaluation, including a focused medical history with an emphasis on controlled substance use, physical and mental status examinations, evaluation of employee adherence to prescription medication instructions, additional drug testing if indicated, use of collateral sources of information, and querying of state prescription monitoring databases. Finally, we propose suggestions for optimizing the evaluation of drug-related workplace impairment.
A new test method for the evaluation of total antioxidant activity of herbal products.
Zaporozhets, Olga A; Krushynska, Olena A; Lipkovska, Natalia A; Barvinchenko, Valentina N
2004-01-14
A new test method for measuring the antioxidant power of herbal products, based on solid-phase spectrophotometry using tetrabenzo-[b,f,j,n][1,5,9,13]-tetraazacyclohexadecine-Cu(II) complex immobilized on silica gel, is proposed. The absorbance of the modified sorbent (lambda(max) = 712 nm) increases proportionally to the total antioxidant activity of the sample solution. The method represents an attractive alternative to the mostly used radical scavenging capacity assays, because they generally require complex long-lasting stages to be carried out. The proposed test method is simple ("drop and measure" procedure is applied), rapid (10 min/sample), requires only the monitoring of time and absorbance, and provides good statistical parameters (s(r)
[Design and experiment of micro biochemical detector based on micro spectrometer].
Yu, Qing-hua; Wen, Zhi-yu; Chen, Gang; Dai, Wei-wei; Liu, Nian-ci; Wu, Xin
2012-03-01
According to the requirements of rapid detection of important life parameters for the sick and wounded, a new micro bio-chemical detection configuration was proposed utilizing continuous spectroscopy analysis, which was founded on MOEMS and embedded technology. The configuration was developed as so much research work was carried out on the detecting objects and methods. Important parameters such as stray light, absorbance linearity, absorbance ratability, stability and temperature accuracy of the instrument were tested, which are all in good agreement with the design requirements. Clinic tests show that it can detect multiple life parameters quickly (Na+, GLU, Hb eg.).
Jadhav, Snehal; Sevior, Danielle; Bhave, Mrinal; Palombo, Enzo A
2014-01-31
Conventional methods used for primary detection of Listeria monocytogenes from foods and subsequent confirmation of presumptive positive samples involve prolonged incubation and biochemical testing which generally require four to five days to obtain a result. In the current study, a simple and rapid proteomics-based MALDI-TOF MS approach was developed to detect L. monocytogenes directly from selective enrichment broths. Milk samples spiked with single species and multiple species cultures were incubated in a selective enrichment broth for 24h, followed by an additional 6h secondary enrichment. As few as 1 colony-forming unit (cfu) of L. monocytogenes per mL of initial selective broth culture could be detected within 30h. On applying the same approach to solid foods previously implicated in listeriosis, namely chicken pâté, cantaloupe and Camembert cheese, detection was achieved within the same time interval at inoculation levels of 10cfu/mL. Unlike the routine application of MALDI-TOF MS for identification of bacteria from solid media, this study proposes a cost-effective and time-saving detection scheme for direct identification of L. monocytogenes from broth cultures.This article is part of a Special Issue entitled: Trends in Microbial Proteomics. Globally, foodborne diseases are major causes of illness and fatalities in humans. Hence, there is a continual need for reliable and rapid means for pathogen detection from food samples. Recent applications of MALDI-TOF MS for diagnostic microbiology focused on detection of microbes from clinical specimens. However, the current study has emphasized its use as a tool for detecting the major foodborne pathogen, Listeria monocytogenes, directly from selective enrichment broths. This proof-of-concept study proposes a detection scheme that is more rapid and simple compared to conventional methods of Listeria detection. Very low levels of the pathogen could be identified from different food samples post-enrichment in selective enrichment broths. Use of this scheme will facilitate rapid and cost-effective testing for this important foodborne pathogen. © 2013.
Exact tests using two correlated binomial variables in contemporary cancer clinical trials.
Yu, Jihnhee; Kepner, James L; Iyer, Renuka
2009-12-01
New therapy strategies for the treatment of cancer are rapidly emerging because of recent technology advances in genetics and molecular biology. Although newer targeted therapies can improve survival without measurable changes in tumor size, clinical trial conduct has remained nearly unchanged. When potentially efficacious therapies are tested, current clinical trial design and analysis methods may not be suitable for detecting therapeutic effects. We propose an exact method with respect to testing cytostatic cancer treatment using correlated bivariate binomial random variables to simultaneously assess two primary outcomes. The method is easy to implement. It does not increase the sample size over that of the univariate exact test and in most cases reduces the sample size required. Sample size calculations are provided for selected designs.
Whole-machine calibration approach for phased array radar with self-test
NASA Astrophysics Data System (ADS)
Shen, Kai; Yao, Zhi-Cheng; Zhang, Jin-Chang; Yang, Jian
2017-06-01
The performance of the missile-borne phased array radar is greatly influenced by the inter-channel amplitude and phase inconsistencies. In order to ensure its performance, the amplitude and the phase characteristics of radar should be calibrated. Commonly used methods mainly focus on antenna calibration, such as FFT, REV, etc. However, the radar channel also contains T / R components, channels, ADC and messenger. In order to achieve on-based phased array radar amplitude information for rapid machine calibration and compensation, we adopt a high-precision plane scanning test platform for phase amplitude test. A calibration approach for the whole channel system based on the radar frequency source test is proposed. Finally, the advantages and the application prospect of this approach are analysed.
The Performance Analysis of a Uav Based Mobile Mapping System Platform
NASA Astrophysics Data System (ADS)
Tsai, M. L.; Chiang, K. W.; Lo, C. F.; Ch, C. H.
2013-08-01
To facilitate applications such as environment detection or disaster monitoring, the development of rapid low cost systems for collecting near real-time spatial information is very critical. Rapid spatial information collection has become an emerging trend for remote sensing and mapping applications. This study develops a Direct Georeferencing (DG) based fixed-wing Unmanned Aerial Vehicle (UAV) photogrammetric platform where an Inertial Navigation System (INS)/Global Positioning System (GPS) integrated Positioning and Orientation System (POS) system is implemented to provide the DG capability of the platform. The performance verification indicates that the proposed platform can capture aerial images successfully. A flight test is performed to verify the positioning accuracy in DG mode without using Ground Control Points (GCP). The preliminary results illustrate that horizontal DG positioning accuracies in the x and y axes are around 5 m with 300 m flight height. The positioning accuracy in the z axis is less than 10 m. Such accuracy is good for near real-time disaster relief. The DG ready function of proposed platform guarantees mapping and positioning capability even in GCP free environments, which is very important for rapid urgent response for disaster relief. Generally speaking, the data processing time for the DG module, including POS solution generalization, interpolation, Exterior Orientation Parameters (EOP) generation, and feature point measurements, is less than one hour.
NASA Astrophysics Data System (ADS)
Berger, Edo; Cenko, Stephen; Schmidt, Brian; Perley, Daniel; Berger, Edo; Fox, Derek; Fruchter, Andrew; Bloom, Joshua; Prochaska, Jason X.; Lopez, Sebastian; Cobb, Bethany; Roth, Kathy; Levan, Andrew; Tanvir, Nial; Rapoport, Sharon; Yuan, Fang; Chornock, Ryan; Wen-Fai, Fong; Morgan, Adam; Wiersema, Klaas; Cucchiara, Antonino
2013-08-01
The study of gamma-ray burst (GRB) afterglows, host galaxies, and associated supernovae (SNe) sheds light on a wide range of open questions in astrophysics, ranging from the deaths of massive stars to cosmic chemical enrichment and the reionization epoch, and soon, the electromagnetic (EM) counterparts of gravitational wave (GW) sources. Over the past decade, Gemini has played a leading role in all aspects of GRB science through its combination of rapid-response spectroscopy and imaging coupled with deep late-time host galaxy, afterglow, and GRB-SN follow-up. Here, we propose to step forward in our long-standing program of ToO observations, with this proposal focusing on "Rapid ToO" science, observations at t <˜ 1 day. In conjunction with an array of multi-wavelength EM facilities, we focus on three key science topics: (1) Identification, characterization, and exploitation of high-redshift GRBs in order to study the evolving IGM and galaxy populations at these redshifts; (2) Studies of short GRB afterglows and their environments to yield insight into the nature of their progenitor population, for connection with forthcoming GW facilities; and (3) Observation of exceptionally energetic bursts detected by the Fermi-LAT instrument, to test models of burst engines and enable their use as testbeds for quantum gravity effects.
NASA Astrophysics Data System (ADS)
Berger, Edo; Fox, Derek; Chornock, Ryan; Fong, Wen-Fai; Cobb, Bethany; Cenko, Brad; Perley, Daniel; Bloom, Joshua; Prochaska, Jason X.; Morgan, Adam; Cucchiara, Antonino; Levan, Andrew; Tanvir, Nial; Fruchter, Andrew; Lopez, Sebastian; Wiersema, Klaas; Roth, Kathy
2014-02-01
The study of gamma-ray burst (GRB) afterglows, host galaxies, and associated supernovae (SNe) sheds light on a wide range of open questions in astrophysics, ranging from the deaths of massive stars to cosmic chemical enrichment and the reionization epoch, and soon, the electromagnetic (EM) counterparts of gravitational wave (GW) sources. Over the past decade, Gemini has played a leading role in all aspects of GRB science through its combination of rapid-response spectroscopy and imaging coupled with deep late-time host galaxy, afterglow, and GRB-SN follow-up. Here, we propose to step forward in our long-standing program of ToO observations, with this proposal focusing on "Rapid ToO" science, observations at t <˜ 1 day. In conjunction with an array of multi-wavelength EM facilities, we focus on three key science topics: (1) Identification, characterization, and exploitation of high-redshift GRBs in order to study the evolving IGM and galaxy populations at these redshifts; (2) Studies of short GRB afterglows and their environments to yield insight into the nature of their progenitor population, for connection with forthcoming GW facilities; and (3) Observation of exceptionally energetic bursts detected by the Fermi-LAT instrument, to test models of burst engines and enable their use as testbeds for quantum gravity effects.
Hong, Sung A; Kwon, Joseph; Kim, Duwoon; Yang, Sung
2015-02-15
Norovirus (NoV) is a foodborne pathogen that can cause sporadic and epidemic gastrointestinal diseases. Rapid screening is crucial to promptly identify the presence of NoV and prevent food poisoning. Here, we present a sensitive, selective, and rapid electrochemical biosensor for the detection of NoV. The proposed electrochemical biosensor is composed of a nanostructured gold electrode conjugated with concanavalin A (ConA). ConA functions as a recognition element that selectively captures NoV. Cyclic voltammetry revealed a linear relationship (R(2) = 0.998) between the current and concentration of NoV (in the range of 10(2) and 10(6) copies/mL), with a relatively short assay time (1h) and a good detection limit (35 copies/mL). Additionally, the signals of Hepatitis A and E in the selectively test were found to be only 2.0% and 2.8% of the NoV signal at an identical concentration of 10(3) copies/mL, proving that the electrochemical biosensor has a selectively of approximately 98%. Moreover, the concentration of NoV was measured in a realistic environment, i.e., a sample solution extracted from lettuce, to demonstrate a potential application of the proposed biosensor (LoD = 60 copies/mL). Copyright © 2014 Elsevier B.V. All rights reserved.
Duan, Zhiqiang; Zhang, Chunxian; Qiao, Yuchun; Liu, Fengjuan; Wang, Deyan; Wu, Mengfan; Wang, Ke; Lv, Xiaoxia; Kong, Xiangmu; Wang, Hua
2017-08-01
A polyhydric polymer-functionalized probe with enhanced aqueous solubility was designed initially by coupling 1-pyrenecarboxyaldehyde (Pyr) onto poly(vinyl alcohol) (PVA) via the one-step condensation reaction. Polyhydric PVA polymer chains could facilitate the Pyr fluorophore with largely improved aqueous solubility and especially strong cyan fluorescence. Importantly, the fluorescence of the PVA-Pyr probes could thereby be quenched specifically by Fe 3+ ions through the strong PVA-Fe 3+ interaction triggering the polymeric probe aggregation. Furthermore, a test strips-based fluorimetric method was developed with the stable and uniform probe distribution by taking advantage of the unique film-forming ability and the depression capacity of "coffee-stain" effects of PVA matrix. The as-developed test strips could allow for the rapid and visual detections of Fe 3+ ions simply by a dipping way, showing a linear concentration range of 5.00-300μM, with the detection limit of 0.73μM. Moreover, the proposed method was applied to the evaluation of Fe 3+ ions in natural water samples, showing the analysis performances better or comparable to those of current detection techniques. This test strips-based fluorimetric strategy promises the extensive applications for the rapid on-site monitoring of Fe 3+ ions in environmental water and the outdoor finding of the potential iron mines. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Zedong; Li, Fei; Xing, Yue; Liu, Zhi; You, Minli; Li, Yingchun; Wen, Ting; Qu, Zhiguo; Ling Li, Xiao; Xu, Feng
2017-12-15
Paper-based microfluidic biosensors have recently attracted increasing attentions in point-of-care testing (POCT) territories benefiting from their affordable, accessible and eco-friendly features, where technologies for fabricating such biosensors are preferred to be equipment free, easy-to-operate and capable of rapid prototyping. In this work, we developed a pen-on-paper (PoP) strategy based on two custom-made pens, i.e., a wax pen and a conductive-ink pen, to fully write paper-based microfluidic biosensors through directly writing both microfluidic channels and electrodes. Particularly, the proposed wax pen is competent to realize one-step fabrication of wax channels on paper, as the melted wax penetrates into paper during writing process without any post-treatments. The practical applications of the fabricated paper-based microfluidic biosensors are demonstrated by both colorimetric detection of Salmonella typhimurium DNA with detection limit of 1nM and electrochemical measurement of glucose with detection limit of 1mM. The developed PoP strategy for making microfluidic biosensors on paper characterized by true simplicity, prominent portability and excellent capability for rapid prototyping shows promising prospect in POCT applications. Copyright © 2017 Elsevier B.V. All rights reserved.
An automatic step adjustment method for average power analysis technique used in fiber amplifiers
NASA Astrophysics Data System (ADS)
Liu, Xue-Ming
2006-04-01
An automatic step adjustment (ASA) method for average power analysis (APA) technique used in fiber amplifiers is proposed in this paper for the first time. In comparison with the traditional APA technique, the proposed method has suggested two unique merits such as a higher order accuracy and an ASA mechanism, so that it can significantly shorten the computing time and improve the solution accuracy. A test example demonstrates that, by comparing to the APA technique, the proposed method increases the computing speed by more than a hundredfold under the same errors. By computing the model equations of erbium-doped fiber amplifiers, the numerical results show that our method can improve the solution accuracy by over two orders of magnitude at the same amplifying section number. The proposed method has the capacity to rapidly and effectively compute the model equations of fiber Raman amplifiers and semiconductor lasers.
Lehmann, Eldon D.; Tarín, Cristina; Bondia, Jorge; Teufel, Edgar; Deutsch, Tibor
2007-01-01
Introduction AIDA v4 is an interactive educational diabetes simulator that has been made available, for over a decade, without charge via the Internet. The software is currently freely accessible at http://www.2aida.org. This report sets out a collaborative development plan to enhance the program with a new model of subcutaneous insulin absorption, which permits the simulation of rapidly acting and very long-acting insulin analogues, as well as insulin injection doses larger than 40 units. Methods A novel, generic, physiological subcutaneous insulin absorption model is overviewed and a methodology is proposed by which this can be substituted in place of the previously adopted insulin absorption model utilized within AIDA v4.3a. Apart from this substitution it is proposed to retain the existing model of the glucoregulatory system currently used in AIDA v4.3a. Results Initial simulation results based on bench testing of this approach using MATLAB are presented for the exogenous insulin flow profile (Iex) following subcutaneous injections of a rapidly acting insulin analogue, a short-acting (regular) insulin preparation, intermediate-acting insulins (both Semilente and neutral protamine Hagedorn types), and a very long-acting insulin analogue. Discussion It is proposed to implement this collaborative development plan—first by bench testing the approach in MATLAB and then by integrating the generic subcutaneous insulin absorption Iex model into the AIDA simulator in Pascal. The aim is to provide enhanced functionality and educational simulations of regimens utilizing novel insulin analogues, as well as injections larger than 40 units of insulin. PMID:19885100
Gao, Bin; Li, Xiaoqing; Woo, Wai Lok; Tian, Gui Yun
2018-05-01
Thermographic inspection has been widely applied to non-destructive testing and evaluation with the capabilities of rapid, contactless, and large surface area detection. Image segmentation is considered essential for identifying and sizing defects. To attain a high-level performance, specific physics-based models that describe defects generation and enable the precise extraction of target region are of crucial importance. In this paper, an effective genetic first-order statistical image segmentation algorithm is proposed for quantitative crack detection. The proposed method automatically extracts valuable spatial-temporal patterns from unsupervised feature extraction algorithm and avoids a range of issues associated with human intervention in laborious manual selection of specific thermal video frames for processing. An internal genetic functionality is built into the proposed algorithm to automatically control the segmentation threshold to render enhanced accuracy in sizing the cracks. Eddy current pulsed thermography will be implemented as a platform to demonstrate surface crack detection. Experimental tests and comparisons have been conducted to verify the efficacy of the proposed method. In addition, a global quantitative assessment index F-score has been adopted to objectively evaluate the performance of different segmentation algorithms.
NASA Astrophysics Data System (ADS)
Takamatsu, Kuniyoshi; Nakagawa, Shigeaki; Takeda, Tetsuaki
Safety demonstration tests using the High Temperature Engineering Test Reactor (HTTR) are in progress to verify its inherent safety features and improve the safety technology and design methodology for High-temperature Gas-cooled Reactors (HTGRs). The reactivity insertion test is one of the safety demonstration tests for the HTTR. This test simulates the rapid increase in the reactor power by withdrawing the control rod without operating the reactor power control system. In addition, the loss of coolant flow tests has been conducted to simulate the rapid decrease in the reactor power by tripping one, two or all out of three gas circulators. The experimental results have revealed the inherent safety features of HTGRs, such as the negative reactivity feedback effect. The numerical analysis code, which was named-ACCORD-, was developed to analyze the reactor dynamics including the flow behavior in the HTTR core. We have modified this code to use a model with four parallel channels and twenty temperature coefficients. Furthermore, we added another analytical model of the core for calculating the heat conduction between the fuel channels and the core in the case of the loss of coolant flow tests. This paper describes the validation results for the newly developed code using the experimental results. Moreover, the effect of the model is formulated quantitatively with our proposed equation. Finally, the pre-analytical result of the loss of coolant flow test by tripping all gas circulators is also discussed.
NASA Technical Reports Server (NTRS)
Dhople, Arvind M.
1994-01-01
In ominous projections issued by both U.S. Public Health Service and the World Health Organization, the epidemic of HIV infection will continue to rise more rapidly worldwide than predicted earlier. The AIDS patients are susceptible to diseases called opportunistic infections of which tuberculosis and Mycobacterium avium complex (MAC) infection are most common. This has created an urgent need to uncover new drugs for the treatment of these infections. In the seventies, NASA scientists at Goddard Space Flight Center, Greenbelt, MD, had adopted a biochemical indicator, adenosine triphosphate (ATP), to detect presence of life in extraterrestrial space. We proposed to develop ATP assay technique to determine sensitivity of antibacterial compounds against MAC and M. tuberculosis.
García-Salgado, Sara; Quijano, M Ángeles
2016-12-01
Ultrasonic probe sonication (UPS) and microwave-assisted extraction (MAE) were used for rapid single extraction of Cd, Cr, Cu, Ni, Pb, and Zn from soils polluted by former mining activities (Mónica Mine, Bustarviejo, NW Madrid, Spain), using 0.01 mol L -1 calcium chloride (CaCl 2 ), 0.43 mol L -1 acetic acid (CH 3 COOH), and 0.05 mol L -1 ethylenediaminetetraacetic acid (EDTA) at pH 7 as extracting agents. The optimum extraction conditions by UPS consisted of an extraction time of 2 min for both CaCl 2 and EDTA extractions and 15 min for CH 3 COOH extraction, at 30% ultrasound (US) amplitude, whereas in the case of MAE, they consisted of 5 min at 50 °C for both CaCl 2 and EDTA extractions and 15 min at 120 °C for CH 3 COOH extraction. Extractable concentrations were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The proposed methods were compared with a reduced version of the corresponding single extraction procedures proposed by the Standards, Measurements and Testing Programme (SM&T). The results obtained showed a great variability on extraction percentages, depending on the metal, the total concentration level and the soil sample, reaching high values in some areas. However, the correlation analysis showed that total concentration is the most relevant factor for element extractability in these soil samples. From the results obtained, the application of the accelerated extraction procedures, such as MAE and UPS, could be considered a useful approach to evaluate rapidly the extractability of the metals studied.
Routine use of point-of-care tests: usefulness and application in clinical microbiology.
Clerc, O; Greub, G
2010-08-01
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shulga, A. V., E-mail: avshulga@mephi.ru
This article comprises the results of comprehensive study of the structure and distribution in the high temperature fracture area of rapidly quenched heat-resistant superalloy of grade EP741NP after tensile tests. The structure and boron distribution in the fracture area are studied in detail by means of direct track autoradiography in combination with metallography of macro- and microstructure. A rather extensive region of microcracks generation and intensive boron redistribution is detected in the high temperature fracture area of rapidly quenched nickel superalloy of grade EP741NP. A significant decrease in boron content in the fracture area and formation of elliptically arranged boridemore » precipitates are revealed. The mechanism of intense boron migration and stability violation of the structural and phase state in the fracture area of rapidly quenched heat-resistant nickel superalloy of grade EP741NP is proposed on the basis of accounting for deformation occurring in the fracture area and analysis of the stressed state near a crack.« less
Screening test for rapid food safety evaluation by menadione-catalysed chemiluminescent assay.
Yamashoji, Shiro; Yoshikawa, Naoko; Kirihara, Masayuki; Tsuneyoshi, Toshihiro
2013-06-15
The chemiluminescent assay of menadione-catalysed H2O2 production by living mammalian cells was proposed to be useful for rapid food safety evaluation. The tested foods were extracted with water, ethanol and dimethylsulfoxide, and each extract was incubated with NIH3T3, Neuro-2a and HepG2 cells for 4h. Menadione-catalysed H2O2 production by living mammalian cells exposed to each extract was determined by the chemiluminescent assay requiring only 10 min, and the viability of the cells was estimated as percentage based on H2O2 production by intact cells. In this study the cytotoxicity of food was rated in order of inhibitory effect on H2O2 production by intact cells. The well known natural toxins such as Fusarium mycotoxin, tomato toxin tomatine, potato toxin solanine and marine toxins terodotoxin and brevetoxin could be detected by the above chemiluminescent assay. Copyright © 2012 Elsevier Ltd. All rights reserved.
Real-time terrain storage generation from multiple sensors towards mobile robot operation interface.
Song, Wei; Cho, Seoungjae; Xi, Yulong; Cho, Kyungeun; Um, Kyhyun
2014-01-01
A mobile robot mounted with multiple sensors is used to rapidly collect 3D point clouds and video images so as to allow accurate terrain modeling. In this study, we develop a real-time terrain storage generation and representation system including a nonground point database (PDB), ground mesh database (MDB), and texture database (TDB). A voxel-based flag map is proposed for incrementally registering large-scale point clouds in a terrain model in real time. We quantize the 3D point clouds into 3D grids of the flag map as a comparative table in order to remove the redundant points. We integrate the large-scale 3D point clouds into a nonground PDB and a node-based terrain mesh using the CPU. Subsequently, we program a graphics processing unit (GPU) to generate the TDB by mapping the triangles in the terrain mesh onto the captured video images. Finally, we produce a nonground voxel map and a ground textured mesh as a terrain reconstruction result. Our proposed methods were tested in an outdoor environment. Our results show that the proposed system was able to rapidly generate terrain storage and provide high resolution terrain representation for mobile mapping services and a graphical user interface between remote operators and mobile robots.
Gong, Yuanzheng; Seibel, Eric J.
2017-01-01
Rapid development in the performance of sophisticated optical components, digital image sensors, and computer abilities along with decreasing costs has enabled three-dimensional (3-D) optical measurement to replace more traditional methods in manufacturing and quality control. The advantages of 3-D optical measurement, such as noncontact, high accuracy, rapid operation, and the ability for automation, are extremely valuable for inline manufacturing. However, most of the current optical approaches are eligible for exterior instead of internal surfaces of machined parts. A 3-D optical measurement approach is proposed based on machine vision for the 3-D profile measurement of tiny complex internal surfaces, such as internally threaded holes. To capture the full topographic extent (peak to valley) of threads, a side-view commercial rigid scope is used to collect images at known camera positions and orientations. A 3-D point cloud is generated with multiview stereo vision using linear motion of the test piece, which is repeated by a rotation to form additional point clouds. Registration of these point clouds into a complete reconstruction uses a proposed automated feature-based 3-D registration algorithm. The resulting 3-D reconstruction is compared with x-ray computed tomography to validate the feasibility of our proposed method for future robotically driven industrial 3-D inspection. PMID:28286351
Real-Time Terrain Storage Generation from Multiple Sensors towards Mobile Robot Operation Interface
Cho, Seoungjae; Xi, Yulong; Cho, Kyungeun
2014-01-01
A mobile robot mounted with multiple sensors is used to rapidly collect 3D point clouds and video images so as to allow accurate terrain modeling. In this study, we develop a real-time terrain storage generation and representation system including a nonground point database (PDB), ground mesh database (MDB), and texture database (TDB). A voxel-based flag map is proposed for incrementally registering large-scale point clouds in a terrain model in real time. We quantize the 3D point clouds into 3D grids of the flag map as a comparative table in order to remove the redundant points. We integrate the large-scale 3D point clouds into a nonground PDB and a node-based terrain mesh using the CPU. Subsequently, we program a graphics processing unit (GPU) to generate the TDB by mapping the triangles in the terrain mesh onto the captured video images. Finally, we produce a nonground voxel map and a ground textured mesh as a terrain reconstruction result. Our proposed methods were tested in an outdoor environment. Our results show that the proposed system was able to rapidly generate terrain storage and provide high resolution terrain representation for mobile mapping services and a graphical user interface between remote operators and mobile robots. PMID:25101321
NASA Astrophysics Data System (ADS)
Gong, Yuanzheng; Seibel, Eric J.
2017-01-01
Rapid development in the performance of sophisticated optical components, digital image sensors, and computer abilities along with decreasing costs has enabled three-dimensional (3-D) optical measurement to replace more traditional methods in manufacturing and quality control. The advantages of 3-D optical measurement, such as noncontact, high accuracy, rapid operation, and the ability for automation, are extremely valuable for inline manufacturing. However, most of the current optical approaches are eligible for exterior instead of internal surfaces of machined parts. A 3-D optical measurement approach is proposed based on machine vision for the 3-D profile measurement of tiny complex internal surfaces, such as internally threaded holes. To capture the full topographic extent (peak to valley) of threads, a side-view commercial rigid scope is used to collect images at known camera positions and orientations. A 3-D point cloud is generated with multiview stereo vision using linear motion of the test piece, which is repeated by a rotation to form additional point clouds. Registration of these point clouds into a complete reconstruction uses a proposed automated feature-based 3-D registration algorithm. The resulting 3-D reconstruction is compared with x-ray computed tomography to validate the feasibility of our proposed method for future robotically driven industrial 3-D inspection.
Towards Detection and Diagnosis of Ebola Virus Disease at Point-of-Care
Kaushik, Ajeet; Tiwari, Sneham; Jayant, Rahul Dev; Marty, Aileen; Nair, Madhavan
2015-01-01
Ebola outbreak-2014 (mainly Zaire strain related Ebola virus) has been declared most widely spread deadly persistent epidemic due to unavailability of rapid diagnostic, detection, and therapeutics. Ebola virus disease (EVD), a severe viral hemorrhagic fever syndrome caused by Ebola virus (EBOV) is transmitted by direct contact with the body fluids of infected person and objects contaminated with virus or infected animals. World Health Organization (WHO) has declared EVD epidemic as public health emergency of international concern with severe global economic burden. At fatal EBOV infection stage, patients usually die before the antibody response. Currently, rapid blood tests to diagnose EBOV infection include the antigen or antibodies capture using ELISA and RNA detection using RT/Q-PCR within 3–10 days after the onset of symptoms. Moreover, few nanotechnology-based colorimetric and paper-based immunoassay methods have been recently reported to detect Ebola virus. Unfortunately, these methods are limited to laboratory only. As state-of-the art (SoA) diagnostics time to confirm Ebola infection, varies from 6 hours to about 3 days, it causes delay in therapeutic approaches. Thus developing a cost-effective, rapid, sensitive, and selective sensor to detect EVD at point-of-care (POC) is certainly worth exploring to establish rapid diagnostics to decide therapeutics. This review highlights SoA of Ebola diagnostics and also a call to develop rapid, selective and sensitive POC detection of EBOV for global health care. We propose that adopting miniaturized electrochemical EBOV immunosensing can detect virus level at pM concentration within ~40 minute compared to 3 days of ELISA test at nM levels. PMID:26319169
Wolf, Matthew
2014-04-01
Aircraft passengers and crew may be subjected to rapid or prolonged decompression to high cabin altitude when an aircraft develops a hole in the fuselage. The accepted measure of neurological damage due to the hypobaric hypoxia produced is the subjective 'time of useful consciousness' (TUC) measure, which is appropriate for pilots and crew who perform their given tasks, however, TUC is measured under conditions different than the decompression scenarios that passengers undergo in today's aircraft. Ernsting proposed that prolonged exposure to alveolar O2 pressures less than 30 mmHg (P30) causes neurological damage. The current study proposes that a critical value of arterial O2 saturation of 70% (S70) can be used in place of P30 and that this physiological measure is more suited for determination of hypobaric hypoxia in passengers. The study shows the equivalence of model-predicted P30 and S70 values in the Ernsting-decompression scenarios. The model is also used to predict values of these physiological measures in actual aircraft-decompression scenarios. The model can be used by others to quantitatively predict the degree of hypobaric hypoxia for virtually any kind of decompression scenario, including those where supplemental O2 is used. Use of this tool avoids the prohibitive costs of human-subject testing for new aircraft and the potential danger inherent in such tests.
Nibhanipudi, Kumara V
2015-01-01
A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) From data configuration Rapid Strep versus LE test don't seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001) reject Null HYPOTHESIS and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.
Merchant, R.C.; Clark, M.A.; Liu, T.; Rosenberger, J.G.; Romanoff, J.; Bauermeister, J.; Mayer, K.H.
2016-01-01
Objectives We assessed preferences of social media-using young black, Hispanic and white men-who-have-sex-with-men (YMSM) for oral fluid rapid HIV self-testing, as compared with other currently available HIV testing options. We also identified aspects of the oral fluid rapid HIV self-test that might influence preferences for using this test instead of other HIV testing options and determined if consideration of HIV testing costs and the potential future availability of fingerstick rapid HIV self-testing change HIV testing preferences. Study design Anonymous online survey. Methods HIV-uninfected YMSM across the United States recruited from multiple social media platforms completed an online survey about willingness to use, opinions about and their preferences for using oral fluid rapid HIV self-testing and five other currently available HIV testing options. In a pre/post questionnaire format design, participants first indicated their preferences for using the six HIV testing options (pre) before answering questions that asked their experience with and opinions about HIV testing. Although not revealed to participants and not apparent in the phrasing of the questions or responses, the opinion questions concerned aspects of oral fluid rapid HIV self-testing (e.g. its possible advantages/disadvantages, merits/demerits, and barriers/facilitators). Afterward, participants were queried again about their HIV testing preferences (post). After completing these questions, participants were asked to re-indicate their HIV testing preferences when considering they had to pay for HIV testing and if fingerstick blood sample rapid HIV self-testing were an additional testing option. Aspects about the oral fluid rapid HIV self-test associated with influencing increased the preference for using the test (post assessment vs pre-assessment of opinion topics) were identified through multivariable regression models that adjusted for participant characteristics. Results Of the 1975 YMSM participants, the median age was 22 years (IQR 20–23); 19% were black, 36% Hispanic, and 45% white; and 18% previously used an oral fluid rapid HIV self-test. Although views about oral fluid rapid HIV self-testing test were favorable, few intended to use the test. Aspects about the oral fluid rapid HIV self-test associated with an increased preference for using the test were its privacy features, that it motivated getting tested more often or as soon as possible, and that it conferred feelings of more control over one’s sexual health. Preferences for the oral fluid rapid HIV self-test were lower when costs were considered, yet these YMSM were much more interested in fingerstick blood sampling than oral fluid sampling rapid HIV self-testing. Conclusions Despite the perceived advantages of the oral fluid rapid HIV self-test and favorable views about it by this population, prior use as well as future intention in using the test were low. Aspects about oral fluid rapid HIV self-testing identified as influential in this study might assist in interventions aimed to increase its use among this high HIV risk population as a means of encouraging regular HIV testing, identifying HIV-infected persons, and linking them to care. Although not yet commercially available in the United States, fingerstick rapid HIV self-testing might help motivate YMSM to be tested more than oral fluid rapid HIV self-testing. PMID:28359394
Merchant, R C; Clark, M A; Liu, T; Rosenberger, J G; Romanoff, J; Bauermeister, J; Mayer, K H
2017-04-01
We assessed preferences of social media-using young black, Hispanic and white men-who-have-sex-with-men (YMSM) for oral fluid rapid HIV self-testing, as compared to other currently available HIV testing options. We also identified aspects of the oral fluid rapid HIV self-test that might influence preferences for using this test instead of other HIV testing options and determined if consideration of HIV testing costs and the potential future availability of fingerstick rapid HIV self-testing change HIV testing preferences. Anonymous online survey. HIV-uninfected YMSM across the United States recruited from multiple social media platforms completed an online survey about willingness to use, opinions about and their preferences for using oral fluid rapid HIV self-testing and five other currently available HIV testing options. In a pre/post questionnaire format design, participants first indicated their preferences for using the six HIV testing options (pre) before answering questions that asked their experience with and opinions about HIV testing. Although not revealed to participants and not apparent in the phrasing of the questions or responses, the opinion questions concerned aspects of oral fluid rapid HIV self-testing (e.g. its possible advantages/disadvantages, merits/demerits, and barriers/facilitators). Afterward, participants were queried again about their HIV testing preferences (post). After completing these questions, participants were asked to re-indicate their HIV testing preferences when considering they had to pay for HIV testing and if fingerstick blood sample rapid HIV self-testing were an additional testing option. Aspects about the oral fluid rapid HIV self-test associated with increased preference for using the test (post-assessment vs pre-assessment of opinion topics) were identified through multivariable regression models that adjusted for participant characteristics. Of the 1975 YMSM participants, the median age was 22 years (IQR 20-23); 19% were black, 36% Hispanic, and 45% white; and 18% previously used an oral fluid rapid HIV self-test. Although views about oral fluid rapid HIV self-testing test were favorable, few intended to use the test. Aspects about the oral fluid rapid HIV self-test associated with an increased preference for using the test were its privacy features, that it motivated getting tested more often or as soon as possible, and that it conferred feelings of more control over one's sexual health. Preferences for the oral fluid rapid HIV self-test were lower when costs were considered, yet these YMSM were much more interested in fingerstick blood sampling than oral fluid sampling rapid HIV self-testing. Despite the perceived advantages of the oral fluid rapid HIV self-test and favorable views about it by this population, prior use as well as future intention in using the test were low. Aspects about oral fluid rapid HIV self-testing identified as influential in this study might assist in interventions aimed to increase its use among this high HIV risk population as a means of encouraging regular HIV testing, identifying HIV-infected persons, and linking them to care. Although not yet commercially available in the United States, fingerstick rapid HIV self-testing might help motivate YMSM to be tested more than oral fluid rapid HIV self-testing. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Gloor, C I; Schweighauser, A; Francey, T; Rodriguez-Campos, S; Vidondo, B; Bigler, B; Schuller, S
2017-03-01
To determine the diagnostic performance of two patient-side tests (RDT-1: Test-it™ and RDT-2 Witness®Lepto) in the early diagnosis of canine leptospirosis. Retrospective study of 108 dogs with leptospirosis and 53 controls. Leptospirosis was diagnosed based on compatible clinical and clinicopathologic signs and either a single microscopic agglutination test titre_ >800 (n=49), seroconversion (n=53), positive urine real time PCR (RT-PCR) (n=1), evidence of spirochaetes in silver-stained tissues (n=1) or a combination of these (n=4). Leptospirosis was excluded in dogs with a convincing alternative diagnosis and single microscopic agglutination testing titres _<200 (n=46) or lack of seroconversion (n=7). Indices of diagnostic accuracy of the rapid diagnostic tests were calculated by comparing admission rapid diagnostic test results to the final disease status. Rapid diagnostic test-1 was performed in 118 dogs, rapid diagnostic test-2 in 69 dogs and both tests in 26 dogs. Weak positive results occurred frequently representing 22·6% (rapid diagnostic test-1) and 32·3% (rapid diagnostic test-2) of all positive tests in dogs with leptospirosis. If weak positive rapid diagnostic tests were considered positive, rapid diagnostic test-1 and rapid diagnostic test-2 had sensitivities of 82 and 76%, specificities of 91 and 100%, positive predictive values of 94% and 100% and negative predictive values of 73% and 74%, respectively. There were some technical problems with rapid diagnostic test-1. The diagnostic performance of the rapid diagnostic tests is similar to that reported for the microscopic agglutination test. Both can support a diagnosis of leptospirosis with high specificity but leptospirosis cannot be excluded based on a negative admission test result. Both RDTs are useful in conjunction with other confirmatory tests. © 2017 British Small Animal Veterinary Association.
Gas-laser behavior in a low-gravity environment
NASA Technical Reports Server (NTRS)
Owen, R. B.
1981-01-01
In connection with several experiments proposed for flight on the Space Shuttle, which involve the use of gas lasers, the behavior of a He-Ne laser in a low-gravity environment has been studied theoretically and experimentally in a series of flight tests using a low-gravity-simulation aircraft. No fluctuation in laser output above the noise level of the meter (1 part in 1000 for 1 hr) was observed during the low-gravity portion of the flight tests. The laser output gradually increased by 1.4% during a 1.5-hr test; at no time were rapid variations observed in the laser output. A maximum laser instability of 1 part in 100 was observed during forty low-gravity parabolic maneuvers. The beam remained Gaussian throughout the tests and no lobe patterns were observed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelbe, David; Oak Ridge National Lab.; van Aardt, Jan
Terrestrial laser scanning has demonstrated increasing potential for rapid comprehensive measurement of forest structure, especially when multiple scans are spatially registered in order to reduce the limitations of occlusion. Although marker-based registration techniques (based on retro-reflective spherical targets) are commonly used in practice, a blind marker-free approach is preferable, insofar as it supports rapid operational data acquisition. To support these efforts, we extend the pairwise registration approach of our earlier work, and develop a graph-theoretical framework to perform blind marker-free global registration of multiple point cloud data sets. Pairwise pose estimates are weighted based on their estimated error, in ordermore » to overcome pose conflict while exploiting redundant information and improving precision. The proposed approach was tested for eight diverse New England forest sites, with 25 scans collected at each site. Quantitative assessment was provided via a novel embedded confidence metric, with a mean estimated root-mean-square error of 7.2 cm and 89% of scans connected to the reference node. Lastly, this paper assesses the validity of the embedded multiview registration confidence metric and evaluates the performance of the proposed registration algorithm.« less
El-Yazbi, Amira F
2017-01-20
Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virusinfection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with <em>P</em>-value > 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.
Strategy escalation: an emerging paradigm for safe clinical development of T cell gene therapies.
Junghans, Richard Paul
2010-06-10
Gene therapy techniques are being applied to modify T cells with chimeric antigen receptors (CARs) for therapeutic ends. The versatility of this platform has spawned multiple options for their application with new permutations in strategies continually being invented, a testimony to the creative energies of many investigators. The field is rapidly expanding with immense potential for impact against diverse cancers. But this rapid expansion, like the Big Bang, comes with a somewhat chaotic evolution of its therapeutic universe that can also be dangerous, as seen by recently publicized deaths. Time-honored methods for new drug testing embodied in Dose Escalation that were suitable for traditional inert agents are now inadequate for these novel "living drugs". In the following, I propose an approach to escalating risk for patient exposures with these new immuno-gene therapy agents, termed Strategy Escalation, that accounts for the molecular and biological features of the modified cells and the methods of their administration. This proposal is offered not as a prescriptive but as a discussion framework that investigators may wish to consider in configuring their intended clinical applications.
Development of magnet configurations for magnetic immunostaining
NASA Astrophysics Data System (ADS)
Kaneko, Miki; Chikaki, Shinichi; Matsuda, Sachiko; Kuwahata, Akihiro; Namita, Masayuki; Saito, Itsuro; Sakamoto, Satoshi; Kusakabe, Moriaki; Sekino, Masaki
2018-05-01
Magnetic immunostaining using a magnet and antibody-labeled fluorescent ferrite (FF) beads is established as a rapid immunostaining. In this study, we proposed the novel configuration of magnets with the large magnetic field gradient and the strong magnetic force for magnetic immunostaining. To confirm the usefulness of the proposed magnet configuration, we performed numerical analysis of the magnetic characteristics of the proposed magnets, and the magnetic immunostaining with FF beads. It was revealed that the proposed magnets generated the strong magnetic force and promoted the immunoreaction rapidly.
Ng, Kamela Charmaine; Meehan, Conor Joseph; Torrea, Gabriela; Goeminne, Léonie; Diels, Maren; Rigouts, Leen; de Jong, Bouke Catherine; André, Emmanuel
2018-02-27
Tuberculosis (TB) is the highest-mortality infectious disease in the world and the main cause of death related to antimicrobial resistance, yet its surveillance is still paper-based. Rifampicin-resistant TB (RR-TB) is an urgent public health crisis. The World Health Organization has, since 2010, endorsed a series of rapid diagnostic tests (RDTs) that enable rapid detection of drug-resistant strains and produce large volumes of data. In parallel, most high-burden countries have adopted connectivity solutions that allow linking of diagnostics, real-time capture, and shared repository of these test results. However, these connected diagnostics and readily available test results are not used to their full capacity, as we have yet to capitalize on fully understanding the relationship between test results and specific rpoB mutations to elucidate its potential application to real-time surveillance. We aimed to validate and analyze RDT data in detail, and propose the potential use of connected diagnostics and associated test results for real-time evaluation of RR-TB transmission. We selected 107 RR-TB strains harboring 34 unique rpoB mutations, including 30 within the rifampicin resistance-determining region (RRDR), from the Belgian Coordinated Collections of Microorganisms, Antwerp, Belgium. We subjected these strains to Xpert MTB/RIF, GenoType MTBDRplus v2.0, and Genoscholar NTM + MDRTB II, the results of which were validated against the strains' available rpoB gene sequences. We determined the reproducibility of the results, analyzed and visualized the probe reactions, and proposed these for potential use in evaluating transmission. The RDT probe reactions detected most RRDR mutations tested, although we found a few critical discrepancies between observed results and manufacturers' claims. Based on published frequencies of probe reactions and RRDR mutations, we found specific probe reactions with high potential use in transmission studies: Xpert MTB/RIF probes A, Bdelayed, C, and Edelayed; Genotype MTBDRplus v2.0 WT2, WT5, and WT6; and Genoscholar NTM + MDRTB II S1 and S3. Inspection of probe reactions of disputed mutations may potentially resolve discordance between genotypic and phenotypic test results. We propose a novel approach for potential real-time detection of RR-TB transmission through fully using digitally linked TB diagnostics and shared repository of test results. To our knowledge, this is the first pragmatic and scalable work in response to the consensus of world-renowned TB experts in 2016 on the potential of diagnostic connectivity to accelerate efforts to eliminate TB. This is evidenced by the ability of our proposed approach to facilitate comparison of probe reactions between different RDTs used in the same setting. Integrating this proposed approach as a plug-in module to a connectivity platform will increase usefulness of connected TB diagnostics for RR-TB outbreak detection through real-time investigation of suspected RR-TB transmission cases based on epidemiologic linking. ©Kamela Charmaine Ng, Conor Joseph Meehan, Gabriela Torrea, Léonie Goeminne, Maren Diels, Leen Rigouts, Bouke Catherine de Jong, Emmanuel André. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 27.02.2018.
Measurement of Energy Performances for General-Structured Servers
NASA Astrophysics Data System (ADS)
Liu, Ren; Chen, Lili; Li, Pengcheng; Liu, Meng; Chen, Haihong
2017-11-01
Energy consumption of servers in data centers increases rapidly along with the wide application of Internet and connected devices. To improve the energy efficiency of servers, voluntary or mandatory energy efficiency programs for servers, including voluntary label program or mandatory energy performance standards have been adopted or being prepared in the US, EU and China. However, the energy performance of servers and testing methods of servers are not well defined. This paper presents matrices to measure the energy performances of general-structured servers. The impacts of various components of servers on their energy performances are also analyzed. Based on a set of normalized workload, the author proposes a standard method for testing energy efficiency of servers. Pilot tests are conducted to assess the energy performance testing methods of servers. The findings of the tests are discussed in the paper.
Schackman, Bruce R.; Leff, Jared A.; Barter, Devra M.; DiLorenzo, Madeline A.; Feaster, Daniel J.; Metsch, Lisa R.; Freedberg, Kenneth A.; Linas, Benjamin P.
2014-01-01
Aims To evaluate the cost-effectiveness of rapid hepatitis C virus (HCV) and simultaneous HCV/HIV antibody testing in substance abuse treatment programs. Design We used a decision analytic model to compare the cost-effectiveness of no HCV testing referral or offer, off-site HCV testing referral, on-site rapid HCV testing offer, and on-site rapid HCV and HIV testing offer. Base case inputs included 11% undetected chronic HCV, 0.4% undetected HIV, 35% HCV co-infection among HIV-infected, 53% linked to HCV care after testing antibody positive, and 67% linked to HIV care. Disease outcomes were estimated from established computer simulation models of HCV (HEP-CE) and HIV (CEPAC). Setting and Participants Data on test acceptance and costs were from a national randomized trial of HIV testing strategies conducted at 12 substance abuse treatment programs in the USA. Measurements Lifetime costs (2011 US dollars) and quality-adjusted life years (QALYs) discounted at 3% annually; incremental cost-effectiveness ratios (ICERs) Findings On-site rapid HCV testing had an ICER of $18,300/QALY compared with no testing, and was more efficient than (dominated) off-site HCV testing referral. On-site rapid HCV and HIV testing had an ICER of $64,500/QALY compared with on-site rapid HCV testing alone. In one and two-way sensitivity analyses, the ICER of on-site rapid HCV and HIV testing remained <$100,000/QALY, except when undetected HIV prevalence was <0.1% or when we assumed frequent HIV testing elsewhere. The ICER remained <$100,000/QALY in approximately 90% of probabilistic sensitivity analyses. Conclusions On-site rapid hepatitis C virus and HIV testing in substance abuse treatment programs is cost-effective at a <$100,000/ quality-adjusted life years threshold. PMID:25291977
Capturing flight system test engineering expertise: Lessons learned
NASA Technical Reports Server (NTRS)
Woerner, Irene Wong
1991-01-01
Within a few years, JPL will be challenged by the most active mission set in history. Concurrently, flight systems are increasingly more complex. Presently, the knowledge to conduct integration and test of spacecraft and large instruments is held by a few key people, each with many years of experience. JPL is in danger of losing a significant amount of this critical expertise, through retirement, during a period when demand for this expertise is rapidly increasing. The most critical issue at hand is to collect and retain this expertise and develop tools that would ensure the ability to successfully perform the integration and test of future spacecraft and large instruments. The proposed solution was to capture and codity a subset of existing knowledge, and to utilize this captured expertise in knowledge-based systems. First year results and activities planned for the second year of this on-going effort are described. Topics discussed include lessons learned in knowledge acquisition and elicitation techniques, life-cycle paradigms, and rapid prototyping of a knowledge-based advisor (Spacecraft Test Assistant) and a hypermedia browser (Test Engineering Browser). The prototype Spacecraft Test Assistant supports a subset of integration and test activities for flight systems. Browser is a hypermedia tool that allows users easy perusal of spacecraft test topics. A knowledge acquisition tool called ConceptFinder which was developed to search through large volumes of data for related concepts is also described and is modified to semi-automate the process of creating hypertext links.
A Nonlinear Digital Control Solution for a DC/DC Power Converter
NASA Technical Reports Server (NTRS)
Zhu, Minshao
2002-01-01
A digital Nonlinear Proportional-Integral-Derivative (NPID) control algorithm was proposed to control a 1-kW, PWM, DC/DC, switching power converter. The NPID methodology is introduced and a practical hardware control solution is obtained. The design of the controller was completed using Matlab (trademark) Simulink, while the hardware-in-the-loop testing was performed using both the dSPACE (trademark) rapid prototyping system, and a stand-alone Texas Instruments (trademark) Digital Signal Processor (DSP)-based system. The final Nonlinear digital control algorithm was implemented and tested using the ED408043-1 Westinghouse DC-DC switching power converter. The NPID test results are discussed and compared to the results of a standard Proportional-Integral (PI) controller.
Sotnikov, Dmitriy V; Byzova, Nadezhda A; Zherdev, Anatoly V; Eskendirova, Saule Z; Baltin, Kairat K; Mukanov, Kasim K; Ramankulov, Erlan M; Sadykhov, Elchin G; Dzantiev, Boris B
2015-01-01
An immunochromatographic test system was developed for rapid detection of the levels of specific IgG antibodies to Brucella abortus lipopolysaccharide, as a tool for diagnosis of brucellosis in cattle. The pilot test strips were examined using blood sera from sick (78 samples) and healthy (35 samples) cows. The results obtained by immunochromatographic assay, using a portable optical densitometer for digital video detection, correlate well with the results obtained by immunoenzyme assay and are in agreement with the results of the disease diagnosis. The new test system allows detection of antibodies within 10 min and can be proposed as an alternative to the methods available for serodiagnosis of brucellosis.
2015-01-01
Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001) reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children. PMID:27335975
An improved PSO-SVM model for online recognition defects in eddy current testing
NASA Astrophysics Data System (ADS)
Liu, Baoling; Hou, Dibo; Huang, Pingjie; Liu, Banteng; Tang, Huayi; Zhang, Wubo; Chen, Peihua; Zhang, Guangxin
2013-12-01
Accurate and rapid recognition of defects is essential for structural integrity and health monitoring of in-service device using eddy current (EC) non-destructive testing. This paper introduces a novel model-free method that includes three main modules: a signal pre-processing module, a classifier module and an optimisation module. In the signal pre-processing module, a kind of two-stage differential structure is proposed to suppress the lift-off fluctuation that could contaminate the EC signal. In the classifier module, multi-class support vector machine (SVM) based on one-against-one strategy is utilised for its good accuracy. In the optimisation module, the optimal parameters of classifier are obtained by an improved particle swarm optimisation (IPSO) algorithm. The proposed IPSO technique can improve convergence performance of the primary PSO through the following strategies: nonlinear processing of inertia weight, introductions of the black hole and simulated annealing model with extremum disturbance. The good generalisation ability of the IPSO-SVM model has been validated through adding additional specimen into the testing set. Experiments show that the proposed algorithm can achieve higher recognition accuracy and efficiency than other well-known classifiers and the superiorities are more obvious with less training set, which contributes to online application.
Zhai, XingChen; Zhang, Hua; Zhang, Min; Yang, Xin; Gu, Cheng; Zhou, GuoPeng; Zhao, HaiTian; Wang, ZhenYu; Dong, AiJun; Wang, Jing
2017-08-01
A rapid monitoring platform for sensitive voltammetric detection of thiamethoxam residues is reported in the present study. A β-cyclodextrin-reduced graphene oxide composite was used as a reinforcing material in electrochemical determination of thiamethoxam. Compared with bare glassy carbon electrodes, the reduction peak currents of thiamethoxam at reduced graphene oxide/glassy carbon electrode and β-cyclodextrin-reduced graphene oxide/glassy carbon electrode were increased by 70- and 124-fold, respectively. The experimental conditions influencing voltammetric determination of thiamethoxam, such as the amount of β-cyclodextrin-reduced graphene oxide, solution pH, temperature, and accumulation time, were optimized. The reduction mechanism and binding affinity of this material is also discussed. Under optimal conditions, the reduction peak currents increased linearly between 0.5 µM and 16 µM concentration of thiamethoxam. The limit of detection was 0.27 µM on the basis of a signal-to-noise ratio of 3. When the proposed method was applied to brown rice in a recovery test, the recoveries were between 92.20% and 113.75%. The results were in good concordance with the high-performance liquid chromatography method. The proposed method therefore provides a promising and effective platform for sensitive and rapid determination of thiamethoxam. Environ Toxicol Chem 2017;36:1991-1997. © 2017 SETAC. © 2017 SETAC.
Lin, Jung-Fu; Ge, Mao-Cheng; Liu, Tsui-Ping; Chang, Shih-Cheng; Lu, Jang-Jih
2017-06-30
Rapid identification of microbes in the bloodstream is crucial in managing septicemia because of its high disease severity, and direct identification from positive blood culture bottles through matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can shorten the turnaround time. Therefore, we developed a simple method for rapid microbiological identification from positive blood cultures by using MALDI-TOF MS. We modified previously developed methods to propose a faster, simpler and more economical method, which includes centrifugation and hemolysis. Specifically, our method comprises two-stage centrifugation with gravitational acceleration (g) at 600g and 3000g, followed by the addition of a lysis buffer and another 3000g centrifugation. In total, 324 monomicrobial bacterial cultures were identified. The success rate of species identification was 81.8%, which is comparable with other complex methods. The identification success rate was the highest for Gram-negative aerobes (85%), followed by Gram-positive aerobes (78.2%) and anaerobes (67%). The proposed method requires less than 10 min, costs less than US$0.2 per usage, and facilitates batch processing. We conclude that this method is feasible for clinical use in microbiology laboratories, and can serve as a reference for treatments or further complementary diagnostic testing. Copyright © 2017. Published by Elsevier B.V.
Ndase, Patrick; Celum, Connie; Kidoguchi, Lara; Ronald, Allan; Fife, Kenneth H; Bukusi, Elizabeth; Donnell, Deborah; Baeten, Jared M
2015-01-01
Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results. We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests. A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits. When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.
El-Moamly, Amal Abdul-Rasheed; El-Sweify, Mohamed Aly; Hafez, Mohamad Abdul
2012-09-01
Lymphatic filariasis (LF) continues to be a major source of permanent disability and an impediment to socio-economic development in 73 countries where more than 1 billion people are at risk and over 120 millions are infected. The global drive to eliminate LF necessitates an increasing demand for valid, reliable and rapid diagnostic tests. This study aimed to assess the performance of the AD12 rapid format immunochromatographic test (ICT) to detect Wuchereria bancrofti circulating antigens, against the combined gold standard: TropBio Og4C3-ELISA (enzyme-linked immunosorbent assay) which detects circulating filarial antigen (CFA) and the nucleopore membrane filtration and microscopic examination. This prospective case-control study involved 647 asymptomatic migrant workers from filariasis-endemic countries. Of these specimens, 32 were positive for microfilaremia using the membrane filtration and microscopy, 142 positive by ELISA (of which 32 had microfilaremia), and 128 positive by the ICT (of which 31 had microfilaremia). The performance of the ICT was calculated against 32 true-positive and 90 true-negative cases. For the detection of CFA, the ICT had a sensitivity of 97% (95% confidence interval [CI] 91-103), specificity 100% (95% CI 100-100), Positive Predictive Value (PPV) 100% (95% CI 100-100), Negative Predictive Value (NPV) 99% (95% CI 97-101); and the total accuracy of the test was 99% (95% CI 98-101). The agreement between ICT and ELISA in detecting W. bancrofti antigens was excellent (kappa = 0.934; p = 0.000). In conclusion, the AD12-ICT test for the detection of W. bancrofti-CFA was sensitive and specific and comparable to the performance of ELISA. The ICT would be a useful additional test to facilitate the proposed strategies for control and elimination of LF. Because it is rapid, simple to perform, and does not require the use of special equipment, the ICT may be most appropriate in screening programs and in monitoring the possible risk of introducing the disease to the non-endemic countries.
Rapid Transfer Alignment of MEMS SINS Based on Adaptive Incremental Kalman Filter.
Chu, Hairong; Sun, Tingting; Zhang, Baiqiang; Zhang, Hongwei; Chen, Yang
2017-01-14
In airborne MEMS SINS transfer alignment, the error of MEMS IMU is highly environment-dependent and the parameters of the system model are also uncertain, which may lead to large error and bad convergence of the Kalman filter. In order to solve this problem, an improved adaptive incremental Kalman filter (AIKF) algorithm is proposed. First, the model of SINS transfer alignment is defined based on the "Velocity and Attitude" matching method. Then the detailed algorithm progress of AIKF and its recurrence formulas are presented. The performance and calculation amount of AKF and AIKF are also compared. Finally, a simulation test is designed to verify the accuracy and the rapidity of the AIKF algorithm by comparing it with KF and AKF. The results show that the AIKF algorithm has better estimation accuracy and shorter convergence time, especially for the bias of the gyroscope and the accelerometer, which can meet the accuracy and rapidity requirement of transfer alignment.
Rapid Transfer Alignment of MEMS SINS Based on Adaptive Incremental Kalman Filter
Chu, Hairong; Sun, Tingting; Zhang, Baiqiang; Zhang, Hongwei; Chen, Yang
2017-01-01
In airborne MEMS SINS transfer alignment, the error of MEMS IMU is highly environment-dependent and the parameters of the system model are also uncertain, which may lead to large error and bad convergence of the Kalman filter. In order to solve this problem, an improved adaptive incremental Kalman filter (AIKF) algorithm is proposed. First, the model of SINS transfer alignment is defined based on the “Velocity and Attitude” matching method. Then the detailed algorithm progress of AIKF and its recurrence formulas are presented. The performance and calculation amount of AKF and AIKF are also compared. Finally, a simulation test is designed to verify the accuracy and the rapidity of the AIKF algorithm by comparing it with KF and AKF. The results show that the AIKF algorithm has better estimation accuracy and shorter convergence time, especially for the bias of the gyroscope and the accelerometer, which can meet the accuracy and rapidity requirement of transfer alignment. PMID:28098829
Wenzler, Eric; Wong, Jordan R.; Goff, Debra A.; Jankowski, Christopher A.; Bauer, Karri A.
2016-01-01
Antimicrobial stewardship programs (ASPs) are challenged with ensuring appropriate antimicrobial use while minimizing expenditures. ASPs have consistently demonstrated improved patient outcomes and significant cost reductions but are continually required to justify the costs of their existence and interventions due to the silo mentality often adopted by hospital administrators. As new technologies and antimicrobials emerge, ASPs are in a constant tug-of-war between providing optimal clinical outcomes and ensuring cost containment. Additionally, robust data on cost-effectiveness of new rapid diagnostic technologies and antimicrobials with subsequent ASP interventions to provide justification are lacking. As the implementation of an ASP will soon be mandatory for acute care hospitals in the United States, ASPs must find ways to justify novel interventions to align themselves with healthcare administrators. This review provides a framework for the justification of implementing a rapid diagnostic test or adding a new antimicrobial to formulary with ASP intervention, reviews approaches to demonstrating cost-effectiveness, and proposes methods for which ASPs may reduce healthcare expenditures via alternative tactics. PMID:27025521
Sun, Guanghao; Matsui, Takemi
2015-01-01
Noncontact measurement of respiratory rate using Doppler radar will play a vital role in future clinical practice. Doppler radar remotely monitors the tiny chest wall movements induced by respiration activity. The most competitive advantage of this technique is to allow users fully unconstrained with no biological electrode attachments. However, the Doppler radar, unlike other contact-type sensors, is easily affected by the random body movements. In this paper, we proposed a time domain autocorrelation model to process the radar signals for rapid and stable estimation of the respiratory rate. We tested the autocorrelation model on 8 subjects in laboratory, and compared the respiratory rates detected by noncontact radar with reference contact-type respiratory effort belt. Autocorrelation model showed the effects of reducing the random body movement noise added to Doppler radar's respiration signals. Moreover, the respiratory rate can be rapidly calculated from the first main peak in the autocorrelation waveform within 10 s.
[Performance of Cholera-SMART and Pathogen-Detection-Kit in the quick diagnosis of cholera].
Bolaños, Hilda María; Acuña, María Teresa; Serrano, Ana María; Obando, Xinia; Mairena, Hazel; Cháves, Lorena; Sandí, Flor; Rodríguez, Gina; Tamplin, Mark L; Pérez, Enrique; Campos, Elena
2004-10-01
To compare the performance of two rapid systems for the diagnosis of cholera with the culture method, and to propose a strategy for improving the specificity and sensitivity of these systems and reducing the costs involved in making a diagnosis. The following institutions participated in the study: the National Bacteriology Referral Center (Centro Nacional de Referencia en Bacteriologia, CNRB) of the Costa Rican Institute for Research and Teaching in Nutrition and Health (Instituto Costarricense de Investigacion y Ensenanza en Nutricion y Salud, INCIENSA) and various hospitals in the provinces of Alajuela, Guanacaste and San Jose, in Costa Rica. A total of 237 feces samples were used to asses the performance of two tests for the rapid detection of Vibrio cholerae 01: the Pathogen Detection Kit (PDK, Intelligent Monitoring Systems, Gainesville, Florida, USA) and Cholera-SMART (New Horizons Diagnostics Corp., Columbia, Maryland, USA), both when applied directly (direct SMART and direct PDK) and when applied to specimens cultured in broth-enriched medium for 6 hours (SMART-6 and CPK-6) and for 18 hours (SMART-18 and PDK-18) at 37 degrees C in alkaline peptone water. Liquid and partially formed stools were cultured and examined by means of the rapid direct test; when the initial result was negative, the tests were repeated after culture for periods of 6 and 18 hours. Rectal and fecal swabs were obtained from feces cultured in enriched-broth medium for 6 and 18 hours. In addition, we studied the sensitivity of the rapid testing systems by using pure cultures of V. cholerae 01 (strain SOS-833, CNRB, Costa Rica) that were incubated for 18 to 24 hours, and we assessed the usefulness of observing motility under the microscope in order to rationalize the use of rapid methods. The sensitivity of the direct SMART test and of the direct PDK test was 100% when samples obtained from liquid and partially formed stools and from the intestinal contents of dead bodies were used. With these samples, the direct SMART procedure showed a specificity of 100%, whereas the direct PDK procedure showed a specificity that ranged from 85.7% to 77.4%, depending on the type of sample. False positives obtained with the direct PDK method turned out to be negative with PDK-6 and PDK-18. Among the rectal and fecal swabs of persons with and without diarrhea or who had received prior treatment with antibiotics, three results that were negative with the SMART-6 procedure and two that were negative with the PDK-6 procedure turned out to be positive with the SMART-18 and PDK-18 procedures, respectively. Both systems showed excellent concordance (kappa index above 0.9) throughout. Both systems were sensitive to 6 x 10(7) colony-forming units per milliliter (cfu/mL), which was concordant with the microscopic observation of 10 microorganisms or more per field with the type of motility that characterizes vibrios (at 1000 x magnification). Samples having fewer than 10 microorganisms with the motility that characterizes vibrios had concentrations between 6 x 10(3) and 6 x 10(6) cfu/mL and became positive only after incubation in enriched-broth medium for 6 to 18 hours. We propose a strategy for diagnosing the presence of V. cholerae 01 infection in less time than it takes with traditional methods, with positive and negative predictive values of 100%. The SMART and PDK systems make it possible to accurately diagnose cholera quickly, don't require sophisticated equipment or highly qualified technical personnel, and perform satisfactorily in field conditions. Through the proposed strategy, it becomes possible to improve the specificity and sensitivity of these systems and to reduce the cost of making a diagnosis, thus making them suitable for use in cholera surveillance in low-income settings where this disease is a serious public health problem.
Huang, Baicheng; Xiao, Xia; Xue, Biyun; Zhou, En-Min
2018-06-24
Porcine reproductive and respiratory syndrome (PRRS), caused by the PRRS virus (PRRSV), is a widespread disease that affects domestic pigs of all ages. Accurate and rapid detection of PRRSV specific neutralizing antibodies levels in a pig herd is beneficial for the evaluation of the herd's immunity to combat the specific viral infection. However, the current methods for viral detection, including fluorescent focus neutralization (FFN) and cytopathic effect (CPE) reduction neutralizing assays, are subjective and time-consuming. Therefore, a Clover-tagged PRRSV virus neutralization assay were developed that instrumentally measures the fluorescence signal of Clover stably expressing by a PRRSV infectious clone for at least 10 passages. Herein, the results showed that the proposed Clover-tagged PRRSV neutralization assay is reliable using instrumental measurements of the fluorescence signal of Clover and allows for rapid detection of neutralizing antibodies against PRRSV. The assay was evaluated by testing swine sera from experimental and field samples, and comparisons were made with the traditional FFN and CPE reduction assays. These results suggest that the Clover-tagged PRRSV infectious clone offers a fast and reliable testing method for neutralizing antibodies and could permit high-throughput screening of new antiviral agents. Copyright © 2018. Published by Elsevier B.V.
RF Microalgal lipid content characterization
Ahmad, Mahmoud Al; Al-Zuhair, Sulaiman; Taher, Hanifa; Hilal-Alnaqbi, Ali
2014-01-01
Most conventional techniques for the determination of microalgae lipid content are time consuming and in most cases are indirect and require excessive sample preparations. This work presents a new technique that utilizes radio frequency (RF) for rapid lipid quantification, without the need for sample preparation. Tests showed that a shift in the resonance frequency of a RF open-ended coaxial resonator and a gradual increase in its resonance magnitude may occur as the lipids content of microalgae cells increases. These response parameters can be then calibrated against actual cellular lipid contents and used for rapid determination of the cellular lipids. The average duration of lipid quantification using the proposed technique was of about 1 minute, which is significantly less than all other conventional techniques, and was achieved without the need for any time consuming treatment steps. PMID:24870372
Bacillus subtilis as a bioindicator for estimating pentachlorophenol toxicity and concentration.
Ayude, M A; Okada, E; González, J F; Haure, P M; Murialdo, S E
2009-05-01
Pentachlorophenol (PCP) and its sodium salt (Na-PCP) are extremely toxic chemicals responsible for important soil and groundwater pollution, mainly caused by wastes from wood-treatment plants, because chlorinated phenols are widely used as wood preservatives. The methods most commonly used for routine analysis of pesticides such as PCP and Na-PCP are high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS). A variety of rapid biological screening tests using marine organisms, bioluminescent bacteria, and enzymes have also been reported. In this study, rapid biological screening analysis using Bacillus subtilis was developed, to assess the biodegradation of PCP and its by-products in liquid samples. An empirical model is proposed for spectrophotometric analysis of Na-PCP concentration after growth of Bacillus subtilis.
Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M
2011-04-01
Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.
Clemente, W T; Rabello, A; Faria, L C; Peruhype-Magalhães, V; Gomes, L I; da Silva, T A M; Nunes, R V P; Iodith, J B; Protil, K Z; Fernandes, H R; Cortes, J R G; Lima, S S S; Lima, A S; Romanelli, R M C
2014-01-01
Visceral leishmaniasis is an uncommon disease in transplant recipients; however, if left untreated, the mortality can be high. If an organ donor or recipient is known to be an asymptomatic Leishmania spp. carrier,monitoring is advised. This study proposes to assess the prevalence of asymptomatic Leishmania spp.infection in liver transplant donors and recipients from an endemic area. A total of 50 liver recipients and 17 liver donors were evaluated by direct parasite search, indirect fluorescent antibody test (IFAT), anti-Leishmania rK39 rapid test and Leishmania spp.DNA detection by polymerase chain reaction (PCR).Leishmania spp. amastigotes were not observed in liver or spleen tissues. Of the 67 serum samples, IFAT was reactive in 1.5% and indeterminate for 17.9%, and the anti-Leishmania rK39 rapid test was negative for all samples. The PCR test was positive for 7.5%, 8.9%, and 5.9% of blood, liver and spleen samples, respectively(accounting for 23.5% of the donors and 8% of the recipients). Leishmania infantum-specific PCR confirmed all positive samples. In conclusion, a high prevalence of asymptomatic L. infantum was observed in donors and recipients from an endemic area, and PCR was the most sensitive method for screening these individuals.
Does a patent foramen ovale influence cognitive function in dialysis patients?
George, Sudhakar; Holt, Stephen; Medford, Nick; Hildick-Smith, David
2013-01-01
Patients with chronic kidney disease on dialysis treatment have poorer cognitive function than age- and sex-matched controls. One proposed mechanism is cerebral microembolisation due to material from the dialysis circuit crossing a patent foramen ovale (PFO). Cognitive testing was carried out in haemodialysis (HD) patients and peritoneal dialysis (PD) patients. Transthoracic echocardiography was used to identify PFO. Follow-up testing 1 year later enabled comparison of cognitive decline between patients with and without a PFO, and between those undergoing different dialysis modalities. 80 patients (aged 60.4 ± 15.0 years) were recruited (51 HD patients and 29 PD controls). A PFO was found in 21% of patients. 83% of dialysis patients suffered a decline in one or more cognitive function tests over 1 year. There was a significant difference in only one test between HD patients with or without a PFO. PD patients showed a more rapid cognitive decline than those on HD. Cognitive decline in dialysis patients is rapid and affects most patients. The presence of a PFO made only subtle differences to the rates of cognitive decline during 1 year of follow-up. Patients with a PFO should not be prevented from considering HD because of concerns of cerebral decline due to microembolisation. Copyright © 2013 S. Karger AG, Basel.
Abay, Serebe; Addissie, Adamu; Davey, Gail; Farsides, Bobbie; Addissie, Thomas
2016-01-01
Informed consent is a key component of bio-medical research involving human participants. However, obtaining informed consent is challenging in low literacy and resource limited settings. Rapid Ethical Assessment (REA) can be used to contextualize and simplify consent information within a given study community. The current study aimed to explore the effects of social, cultural, and religious factors during informed consent process on a proposed HPV-serotype prevalence study. A qualitative community-based REA was conducted in Adigudom and Mynebri Kebeles, Northern Ethiopia, from July to August 2013. Data were collected by a multi-disciplinary team using open ended questions concerning informed consent components in relation to the parent study. The team conducted one-to-one In-Depth Interviews (IDI) and Focus Group Discussions (FGDs) with key informants and community members to collect data based on the themes of the study. Tape recorded data were transcribed in Tigrigna and then translated into English. Data were categorized and thematically analyzed using open coding and content analysis based on pre-defined themes. The REA study revealed a number of socio-cultural issues relevant to the proposed study. Low community awareness about health research, participant rights and cervical cancer were documented. Giving a vaginal sample for testing was considered to be highly embarrassing, whereas giving a blood sample made participants worry that they might be given a result without the possibility of treatment. Verbal consent was preferred to written consent for the proposed study. This rapid ethical assessment disclosed important socio-cultural issues which might act as barriers to informed decision making. The findings were important for contextual modification of the Information Sheet, and to guide the best consent process for the proposed study. Both are likely to have enabled participants to understand the informed consent better and consequently to comply with the study.
Beware of being captured by an analogy: dreams are like many things.
Erdelyi, Matthew Hugh
2013-12-01
Classic traditions have linked dreams to memory (e.g., "dreaming is another kind of remembering" [Freud 1918/1955]) and modern notions like implicit memory subsume dreaming by definition. Llewellyn develops the more specific thesis that rapid eye movement (REM) dreams, because of their similarities to mnemonic techniques, have the function of elaboratively encoding episodic memories. This proposal is premature, requiring exigent testing. Other analogs of dreams, for example, jokes, do not invoke function but do contribute to dream science.
1991-11-19
economy with a primary emphasis on the exploitation of now extinct megafauna (Gardner 1974, Goodyear et al. 1979, Martin and Klein 1984). Evidence...associated with the rapidly changing Early Holocene environments and animal populations. While exploitation of megafauna during the Early Paleoindian Period...cash- crop economy resulted in the abandonment of old fields once they were depleted of their nutrients and the clearing of new fields. Eventually
Hybrid network defense model based on fuzzy evaluation.
Cho, Ying-Chiang; Pan, Jen-Yi
2014-01-01
With sustained and rapid developments in the field of information technology, the issue of network security has become increasingly prominent. The theme of this study is network data security, with the test subject being a classified and sensitive network laboratory that belongs to the academic network. The analysis is based on the deficiencies and potential risks of the network's existing defense technology, characteristics of cyber attacks, and network security technologies. Subsequently, a distributed network security architecture using the technology of an intrusion prevention system is designed and implemented. In this paper, first, the overall design approach is presented. This design is used as the basis to establish a network defense model, an improvement over the traditional single-technology model that addresses the latter's inadequacies. Next, a distributed network security architecture is implemented, comprising a hybrid firewall, intrusion detection, virtual honeynet projects, and connectivity and interactivity between these three components. Finally, the proposed security system is tested. A statistical analysis of the test results verifies the feasibility and reliability of the proposed architecture. The findings of this study will potentially provide new ideas and stimuli for future designs of network security architecture.
Ko, Fiona; Drews, Steven J
2017-10-01
Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.
QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.
Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria
2011-04-01
To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.
Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P.
2017-01-01
ABSTRACT Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. PMID:28356414
Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P; Graf, Erin H
2017-06-01
Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. Copyright © 2017 American Society for Microbiology.
Demorat, Hubert; Lopes, Amanda; Chopin, Dorothée; Delcey, Véronique; Clevenbergh, Philippe; Simoneau, Guy; Evans, John; Mouly, Stéphane; Bergmann, Jean-François; Sellier, Pierre
2018-02-01
Guidelines recommend routine universal HIV testing in adults to reduce the pool of infected patients unaware of their status, without specific recommendations concerning the method. We compared acceptability and feasibility of HIV testing by ELISA tests or rapid tests from finger-stick whole blood. Prospective randomized multi-center study comparing acceptability and feasibility of routine universal HIV testing by ELISA tests, with a charge, subsequently reimbursed by Social Security for affiliated patients, or rapid tests from finger-stick whole blood, without any charge from the patients or the general practitioner for the study. A single investigator performed all interventions. After consent, all adults (18-70 years old) consulting their general practitioner in Paris, France, unaware of their status, were enrolled. Testing was performed immediately for the patients in the rapid test arm; a prescription was given for testing in a lab for the patients in the ELISA arm. The primary endpoint was acceptability of each method. The secondary endpoint was feasibility of each method, assessed one month after the consultation. Two hundred and seventy patients were enrolled: 133 patients in the ELISA arm, 137 in the rapid test arm. Acceptability of the rapid test (92%) was higher than that of the ELISA (63.9%), P<0.0001. Feasibility of the rapid test (100%) was higher than that of the ELISA (50.5%), P<0.0001. A center effect was shown concerning feasibility of ELISA but not concerning feasibility of rapid tests. Rapid testing from finger-stick whole blood is more acceptable and feasible than ELISA for routine universal HIV testing. A larger use of rapid tests, ideally free of charge, by general practitioners could reduce the pool of infected patients unaware of their status. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Poirel, Laurent; Fernández, Javier; Nordmann, Patrice
2016-02-01
Enterobacterial isolates producing clavulanic-inhibited extended-spectrum β-lactamases (ESBLs) are increasingly spreading in the community and are often responsible for nosocomial infections. Rapid biochemical tests have been developed recently for their detection. Three tests, namely, the Rapid ESBL NDP test, the β-Lacta test, and the Rapid ESBL Screen, have been evaluated with a collection of 108 well-characterized strains, including wild-type strains, strains producing ESBLs, overexpressed cephalosporinases, and carbapenemases. The ESBL NDP test and the Rapid ESBL Screen (a copy of the ESBL NDP test) are aimed at detecting ESBL producers, while the β-Lacta test is aimed at detecting not only ESBL producers but also cephalosporinase and carbapenemase producers. The sensitivity and specificity for detecting ESBL producers (n = 60) were 95% and 100% for the Rapid ESBL NDP test, 80% and 87% (after 30 min) and 92% and 83% (after 2 h) for the Rapid ESBL Screen, and 88% and 71% for the β-Lacta test, respectively. Varied and time-consuming detection (up to 2 h) of ESBLs by the Rapid ESBL Screen and concomitant and varied detection of producers of AmpC and several types of carbapenemases correspond to significant shortcomings of using the Rapid Screen ESBL and β-Lacta tests, respectively. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Warid, Warid; Hizam, Hashim; Mariun, Norman; Abdul-Wahab, Noor Izzri
2016-01-01
This paper proposes a new formulation for the multi-objective optimal power flow (MOOPF) problem for meshed power networks considering distributed generation. An efficacious multi-objective fuzzy linear programming optimization (MFLP) algorithm is proposed to solve the aforementioned problem with and without considering the distributed generation (DG) effect. A variant combination of objectives is considered for simultaneous optimization, including power loss, voltage stability, and shunt capacitors MVAR reserve. Fuzzy membership functions for these objectives are designed with extreme targets, whereas the inequality constraints are treated as hard constraints. The multi-objective fuzzy optimal power flow (OPF) formulation was converted into a crisp OPF in a successive linear programming (SLP) framework and solved using an efficient interior point method (IPM). To test the efficacy of the proposed approach, simulations are performed on the IEEE 30-busand IEEE 118-bus test systems. The MFLP optimization is solved for several optimization cases. The obtained results are compared with those presented in the literature. A unique solution with a high satisfaction for the assigned targets is gained. Results demonstrate the effectiveness of the proposed MFLP technique in terms of solution optimality and rapid convergence. Moreover, the results indicate that using the optimal DG location with the MFLP algorithm provides the solution with the highest quality.
Warid, Warid; Hizam, Hashim; Mariun, Norman; Abdul-Wahab, Noor Izzri
2016-01-01
This paper proposes a new formulation for the multi-objective optimal power flow (MOOPF) problem for meshed power networks considering distributed generation. An efficacious multi-objective fuzzy linear programming optimization (MFLP) algorithm is proposed to solve the aforementioned problem with and without considering the distributed generation (DG) effect. A variant combination of objectives is considered for simultaneous optimization, including power loss, voltage stability, and shunt capacitors MVAR reserve. Fuzzy membership functions for these objectives are designed with extreme targets, whereas the inequality constraints are treated as hard constraints. The multi-objective fuzzy optimal power flow (OPF) formulation was converted into a crisp OPF in a successive linear programming (SLP) framework and solved using an efficient interior point method (IPM). To test the efficacy of the proposed approach, simulations are performed on the IEEE 30-busand IEEE 118-bus test systems. The MFLP optimization is solved for several optimization cases. The obtained results are compared with those presented in the literature. A unique solution with a high satisfaction for the assigned targets is gained. Results demonstrate the effectiveness of the proposed MFLP technique in terms of solution optimality and rapid convergence. Moreover, the results indicate that using the optimal DG location with the MFLP algorithm provides the solution with the highest quality. PMID:26954783
Acceptability of rapid HIV diagnosis technology among primary healthcare practitioners in Spain.
Agustí, C; Fernàndez-López, L; Mascort, J; Carrillo, R; Aguado, C; Montoliu, A; Puigdengolas, X; De La Poza, M; Rifà, B; Casabona, J
2013-01-01
This study investigated the acceptability of rapid HIV testing among general practitioners (GP) and aimed to identify perceived barriers and needs in order to implement rapid testing in primary care settings. An anonymous questionnaire was distributed online to all members of the two largest Spanish scientific medical societies for family and community medicine. The study took place between 15 June 2012 and 31 October 2010. Completed questionnaires were returned by 1308 participants. The majority (90.8%) of respondents were GP. Among all respondents, 70.4% were aware of the existence of rapid tests for the diagnosis of HIV but they did not know how to use them. Nearly 80% of participants would be willing to offer rapid HIV testing in their practices and 74.7% would be confident of the result obtained by these tests. The barriers most commonly identified by respondents were a lack of time and a need for training, both in the use of rapid tests (44.3% and 56.4%, respectively) and required pre- and post-test counselling (59.2% and 34.5%, respectively). This study reveals a high level of acceptance and willingness on the part of GPs to offer rapid HIV testing in their practices. Nevertheless, the implementation of rapid HIV testing in primary care will not be possible without moving from comprehensive pre-test counselling towards brief pre-test information and improving training in the use of rapid tests.
Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala
2017-10-01
As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.
Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala
2017-01-01
As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982
Choi, Jaewon; Jung, Hyung-Sup; Yun, Sang-Ho
2015-03-09
As the aerospace industry grows, images obtained from Earth observation satellites have been successfully used in various fields. Specifically, the demand for a high-resolution (HR) optical images is gradually increasing, and hence the generation of a high-quality mosaic image is being magnified as an interesting issue. In this paper, we have proposed an efficient mosaic algorithm for HR optical images that are significantly different due to seasonal change. The algorithm includes main steps such as: (1) seamline extraction from gradient magnitude and seam images; (2) histogram matching; and (3) image feathering. Eleven Kompsat-2 images characterized by seasonal variations are used for the performance validation of the proposed method. The results of the performance test show that the proposed method effectively mosaics Kompsat-2 adjacent images including severe seasonal changes. Moreover, the results reveal that the proposed method is applicable to HR optic images such as GeoEye, IKONOS, QuickBird, RapidEye, SPOT, WorldView, etc.
Image-guided spatial localization of heterogeneous compartments for magnetic resonance
An, Li; Shen, Jun
2015-01-01
Purpose: Image-guided localization SPectral Localization Achieved by Sensitivity Heterogeneity (SPLASH) allows rapid measurement of signals from irregularly shaped anatomical compartments without using phase encoding gradients. Here, the authors propose a novel method to address the issue of heterogeneous signal distribution within the localized compartments. Methods: Each compartment was subdivided into multiple subcompartments and their spectra were solved by Tikhonov regularization to enforce smoothness within each compartment. The spectrum of a given compartment was generated by combining the spectra of the components of that compartment. The proposed method was first tested using Monte Carlo simulations and then applied to reconstructing in vivo spectra from irregularly shaped ischemic stroke and normal tissue compartments. Results: Monte Carlo simulations demonstrate that the proposed regularized SPLASH method significantly reduces localization and metabolite quantification errors. In vivo results show that the intracompartment regularization results in ∼40% reduction of error in metabolite quantification. Conclusions: The proposed method significantly reduces localization errors and metabolite quantification errors caused by intracompartment heterogeneous signal distribution. PMID:26328977
A cognitive mobile BTS solution with software-defined radioelectric sensing.
Muñoz, Jorge; Alonso, Javier Vales; García, Francisco Quiñoy; Costas, Sergio; Pillado, Marcos; Castaño, Francisco Javier González; Sánchez, Manuel García; Valcarce, Roberto López; Bravo, Cristina López
2013-02-05
Private communications inside large vehicles such as ships may be effectively provided using standard cellular systems. In this paper we propose a new solution based on software-defined radio with electromagnetic sensing support. Software-defined radio allows low-cost developments and, potentially, added-value services not available in commercial cellular networks. The platform of reference, OpenBTS, only supports single-channel cells. Our proposal, however, has the ability of changing BTS channel frequency without disrupting ongoing communications. This ability should be mandatory in vehicular environments, where neighbouring cell configurations may change rapidly, so a moving cell must be reconfigured in real-time to avoid interferences. Full details about frequency occupancy sensing and the channel reselection procedure are provided in this paper. Moreover, a procedure for fast terminal detection is proposed. This may be decisive in emergency situations, e.g., if someone falls overboard. Different tests confirm the feasibility of our proposal and its compatibility with commercial GSM terminals.
A Cognitive Mobile BTS Solution with Software-Defined Radioelectric Sensing
Muñoz, Jorge; Alonso, Javier Vales; García, Francisco Quiñoy; Costas, Secundino; Pillado, Marcos; Castaño, Francisco Javier González; Sánchez, Manuel Garćia; Valcarce, Roberto López; Bravo, Cristina López
2013-01-01
Private communications inside large vehicles such as ships may be effectively provided using standard cellular systems. In this paper we propose a new solution based on software-defined radio with electromagnetic sensing support. Software-defined radio allows low-cost developments and, potentially, added-value services not available in commercial cellular networks. The platform of reference, OpenBTS, only supports single-channel cells. Our proposal, however, has the ability of changing BTS channel frequency without disrupting ongoing communications. This ability should be mandatory in vehicular environments, where neighbouring cell configurations may change rapidly, so a moving cell must be reconfigured in real-time to avoid interferences. Full details about frequency occupancy sensing and the channel reselection procedure are provided in this paper. Moreover, a procedure for fast terminal detection is proposed. This may be decisive in emergency situations, e.g., if someone falls overboard. Different tests confirm the feasibility of our proposal and its compatibility with commercial GSM terminals. PMID:23385417
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakhleh, Luay
I proposed to develop computationally efficient tools for accurate detection and reconstruction of microbes' complex evolutionary mechanisms, thus enabling rapid and accurate annotation, analysis and understanding of their genomes. To achieve this goal, I proposed to address three aspects. (1) Mathematical modeling. A major challenge facing the accurate detection of HGT is that of distinguishing between these two events on the one hand and other events that have similar "effects." I proposed to develop a novel mathematical approach for distinguishing among these events. Further, I proposed to develop a set of novel optimization criteria for the evolutionary analysis of microbialmore » genomes in the presence of these complex evolutionary events. (2) Algorithm design. In this aspect of the project, I proposed to develop an array of e cient and accurate algorithms for analyzing microbial genomes based on the formulated optimization criteria. Further, I proposed to test the viability of the criteria and the accuracy of the algorithms in an experimental setting using both synthetic as well as biological data. (3) Software development. I proposed the nal outcome to be a suite of software tools which implements the mathematical models as well as the algorithms developed.« less
Vyas, S; Puwar, B; Patel, V; Bhatt, G; Kulkarni, S; Fancy, M
2014-05-01
Light microscopy of blood smears for diagnosis of malaria in the field has several limitations, notably delays in diagnosis. This study in Ahmedabad in Gujarat State, India, evaluated the diagnostic performance of a rapid diagnostic test for malaria (SD Bioline Malaria Ag P.f/Pan) versus blood smear examination as the gold standard. All fever cases presenting at 13 urban health centres were subjected to rapid diagnostic testing and thick and thin blood smears. A total of 677 cases with fever were examined; 135 (20.0%) tested positive by rapid diagnostic test and 86 (12.7%) by blood smear. The sensitivity of the rapid diagnostic test for malaria was 98.8%, specificity was 91.5%, positive predictive value 63.0% and negative predictive value 99.8%. For detection of Plasmodium falciparum the sensitivity of rapid diagnostic test was 100% and specificity was 97.3%. The results show the acceptability of the rapid test as an alternative to light microscopy in the field setting.
Experimental comparisons of hypothesis test and moving average based combustion phase controllers.
Gao, Jinwu; Wu, Yuhu; Shen, Tielong
2016-11-01
For engine control, combustion phase is the most effective and direct parameter to improve fuel efficiency. In this paper, the statistical control strategy based on hypothesis test criterion is discussed. Taking location of peak pressure (LPP) as combustion phase indicator, the statistical model of LPP is first proposed, and then the controller design method is discussed on the basis of both Z and T tests. For comparison, moving average based control strategy is also presented and implemented in this study. The experiments on a spark ignition gasoline engine at various operating conditions show that the hypothesis test based controller is able to regulate LPP close to set point while maintaining the rapid transient response, and the variance of LPP is also well constrained. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Thermal testing techniques for space shuttle thermal protection system panels
NASA Technical Reports Server (NTRS)
Cox, B. G.
1972-01-01
An experimental system was developed for evaluation of the effects of aerodynamic heating and cooling, vacuum, and pressure loading on candidate insulation packages proposed for use on the space shuttle. The system includes a number of design features which facilitate rapid recycle times. This is necessary to efficiently conduct extensive thermal cycling tests on these insulation packages to determine their reuse capabilities. The heart of the system is a 26-inch graphite element radiant heater. A susceptor plate functions as a uniform-temperature intermediate radiating surface. The susceptor also forms the lid of an inert atmosphere enclosure which separates the heater from the oxidizing test atmosphere. In some tests the plate properly simulates the heating from an actual flight heat-shield panel. Although other materials were used at lower required test temperatures, 2500 F was routinely achieved using a coated columbium susceptor plate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raskin, Cody; Owen, J. Michael, E-mail: raskin1@llnl.gov, E-mail: mikeowen@llnl.gov
2016-11-01
We discuss a generalization of the classic Keplerian disk test problem allowing for both pressure and rotational support, as a method of testing astrophysical codes incorporating both gravitation and hydrodynamics. We argue for the inclusion of pressure in rotating disk simulations on the grounds that realistic, astrophysical disks exhibit non-negligible pressure support. We then apply this test problem to examine the performance of various smoothed particle hydrodynamics (SPH) methods incorporating a number of improvements proposed over the years to address problems noted in modeling the classical gravitation-only Keplerian disk. We also apply this test to a newly developed extension ofmore » SPH based on reproducing kernels called CRKSPH. Counterintuitively, we find that pressure support worsens the performance of traditional SPH on this problem, causing unphysical collapse away from the steady-state disk solution even more rapidly than the purely gravitational problem, whereas CRKSPH greatly reduces this error.« less
Erb, Julia; Ludwig, Alexandra Annemarie; Kunke, Dunja; Fuchs, Michael; Obleser, Jonas
2018-04-24
Psychoacoustic tests assessed shortly after cochlear implantation are useful predictors of the rehabilitative speech outcome. While largely independent, both spectral and temporal resolution tests are important to provide an accurate prediction of speech recognition. However, rapid tests of temporal sensitivity are currently lacking. Here, we propose a simple amplitude modulation rate discrimination (AMRD) paradigm that is validated by predicting future speech recognition in adult cochlear implant (CI) patients. In 34 newly implanted patients, we used an adaptive AMRD paradigm, where broadband noise was modulated at the speech-relevant rate of ~4 Hz. In a longitudinal study, speech recognition in quiet was assessed using the closed-set Freiburger number test shortly after cochlear implantation (t0) as well as the open-set Freiburger monosyllabic word test 6 months later (t6). Both AMRD thresholds at t0 (r = -0.51) and speech recognition scores at t0 (r = 0.56) predicted speech recognition scores at t6. However, AMRD and speech recognition at t0 were uncorrelated, suggesting that those measures capture partially distinct perceptual abilities. A multiple regression model predicting 6-month speech recognition outcome with deafness duration and speech recognition at t0 improved from adjusted R = 0.30 to adjusted R = 0.44 when AMRD threshold was added as a predictor. These findings identify AMRD thresholds as a reliable, nonredundant predictor above and beyond established speech tests for CI outcome. This AMRD test could potentially be developed into a rapid clinical temporal-resolution test to be integrated into the postoperative test battery to improve the reliability of speech outcome prognosis.
NASA Astrophysics Data System (ADS)
Han, Youmei; Jiao, Minglian; Shijuan
2018-04-01
With the rapid development of the oblique photogrammetry, many cities have built some real 3D model with this technology. Although it has the advantages of short period, high efficiency and good air angle effect, the near ground view angle of these real 3D models are not very good. With increasing development of smart cities, the requirements of reality, practicality and accuracy on real 3D models are becoming higher. How to produce and improve the real 3D models quickly has become one of the hot research directions of geospatial information. To meet this requirement In this paper, Combined with the characteristics of current oblique photogrammetry modeling and the terrestrial photogrammetry, we proposed a new technological process, which consists of close range sensor design, data acquisition and processing. The proposed method is being tested by using oblique photography images acquired. The results confirm the effectiveness of the proposed approach.
Water flow algorithm decision support tool for travelling salesman problem
NASA Astrophysics Data System (ADS)
Kamarudin, Anis Aklima; Othman, Zulaiha Ali; Sarim, Hafiz Mohd
2016-08-01
This paper discuss about the role of Decision Support Tool in Travelling Salesman Problem (TSP) for helping the researchers who doing research in same area will get the better result from the proposed algorithm. A study has been conducted and Rapid Application Development (RAD) model has been use as a methodology which includes requirement planning, user design, construction and cutover. Water Flow Algorithm (WFA) with initialization technique improvement is used as the proposed algorithm in this study for evaluating effectiveness against TSP cases. For DST evaluation will go through usability testing conducted on system use, quality of information, quality of interface and overall satisfaction. Evaluation is needed for determine whether this tool can assists user in making a decision to solve TSP problems with the proposed algorithm or not. Some statistical result shown the ability of this tool in term of helping researchers to conduct the experiments on the WFA with improvements TSP initialization.
Ibarra-Zatarain, Z; Fatsini, E; Rey, S; Chereguini, O; Martin, I; Rasines, I; Alcaraz, C; Duncan, N
2016-11-01
The aim of this work was to characterize stress coping styles of Senegalese sole ( Solea senegalensis ) juveniles and breeders and to select an operational behavioural screening test (OBST) that can be used by the aquaculture industry to classify and select between behavioural phenotypes in order to improve production indicators. A total of 61 juveniles and 59 breeders were subjected to five individual behavioural tests and two grouping tests. At the end of the individual tests, all animals were blood sampled in order to measure cortisol, glucose and lactate. Three tests (restraining, new environment and confinement) characterized the stress coping style behaviour of Senegalese sole juveniles and breeders and demonstrated inter-individual consistency. Further, the tests when incorporated into a principal components analysis (PCA) (i) identified two principal axes of personality traits: 'fearfulness-reactivity' and 'activity-exploration', (ii) were representative of the physiological axis of stress coping style, and (iii) were validated by established group tests. This study proposed for the first time three individual coping style tests that reliably represented proactive and reactive personalities of Senegalese sole juveniles and breeders. In addition, the three proposed tests met some basic operational criteria (rapid testing, no special equipment and easy to apply and interpret) that could prove attractive for fish farmers to identify fish with a specific behaviour that gives advantages in the culture system and that could be used to establish selection-based breeding programmes to improve domestication and production.
Fatsini, E.; Rey, S.; Chereguini, O.; Martin, I.; Rasines, I.; Duncan, N.
2016-01-01
The aim of this work was to characterize stress coping styles of Senegalese sole (Solea senegalensis) juveniles and breeders and to select an operational behavioural screening test (OBST) that can be used by the aquaculture industry to classify and select between behavioural phenotypes in order to improve production indicators. A total of 61 juveniles and 59 breeders were subjected to five individual behavioural tests and two grouping tests. At the end of the individual tests, all animals were blood sampled in order to measure cortisol, glucose and lactate. Three tests (restraining, new environment and confinement) characterized the stress coping style behaviour of Senegalese sole juveniles and breeders and demonstrated inter-individual consistency. Further, the tests when incorporated into a principal components analysis (PCA) (i) identified two principal axes of personality traits: ‘fearfulness-reactivity’ and ‘activity-exploration’, (ii) were representative of the physiological axis of stress coping style, and (iii) were validated by established group tests. This study proposed for the first time three individual coping style tests that reliably represented proactive and reactive personalities of Senegalese sole juveniles and breeders. In addition, the three proposed tests met some basic operational criteria (rapid testing, no special equipment and easy to apply and interpret) that could prove attractive for fish farmers to identify fish with a specific behaviour that gives advantages in the culture system and that could be used to establish selection-based breeding programmes to improve domestication and production. PMID:28018634
ERIC Educational Resources Information Center
Abu-Hamour, Bashir
2013-01-01
This study examined the acceptability, reliability, and validity of the Arabic translated version of the Rapid Automatized Naming and Rapid Alternating Stimulus Tests (RAN/RAS; Wolf & Denckla, 2005) for Jordanian students. RAN/RAS tests are a vital assessment tool to distinguish good readers from poor readers. These tests have been…
Merchant, Roland C.; Clark, Melissa A.; Seage, George R.; Mayer, Kenneth H.; DeGruttola, Victor G.; Becker, Bruce M.
2011-01-01
The aim of this investigation was to assess emergency department (ED) patients’ perceptions and preferences about an opt-in, universal, rapid HIV screening program and identify patient groups who expressed stronger beliefs about components of the testing program. From July 2005 to July 2006, ED patients in the opt-in, universal, rapid HIV screening program were interviewed in person. Multivariable regression models were used to compare participants on their beliefs about the program components. Of the 561 participants, 62.0% had previously been tested for HIV. The majority of participants (58.8%) believed the rapid and standard/conventional HIV tests to be equally accurate, 27.7% believed the rapid test to be less or much less accurate, and 8.7% believed the rapid test to be more or much more accurate. Almost two-thirds (65.1%) favored having a rapid instead of a standard/conventional HIV test, 94.6% wanted the test results within one hour, and 61.3% would be likely or very likely to undergo testing in the ED if it prolonged their ED visit. Almost all (92.5%) believed that their medical care was “not at all” delayed because of being tested, 94.1% believed that testing did “not at all” divert attention from the reason for their ED visit, and 80.9% thought that testing in the ED was “not at all” stressful. In multivariable logistic regression models, males and those with more than 12 years of formal education showed greater concerns about the rapid HIV test’s accuracy. Hispanic/Latinos, participants with governmental insurance, and those previously HIV tested were more apt to be screened for HIV even if testing delayed their ED departure. Overall, participants were highly accepting of the components of this opt-in rapid HIV screening program. However, concerns regarding the accuracy of the rapid HIV test might limit test acceptance and should be addressed during pre-test information procedures. PMID:19283644
Rapid Diagnostic Tests for Identifying Avian Influenza A(H7N9) Virus in Clinical Samples
Chen, Yu; Wang, Dayan; Zheng, Shufa; Shu, Yuelong; Chen, Wenxiang; Cui, Dawei; Li, Jinming; Yu, Hongjie; Wang, Yu; Li, Lanjuan
2015-01-01
To determine sensitivity of rapid diagnostic tests for detecting influenza A(H7N9) virus, we compared rapid tests with PCR results and tested different types of clinical samples. Usefulness of seasonal influenza rapid tests for A(H7N9) virus infections is limited because of their low sensitivity for detecting virus in upper respiratory tract specimens. PMID:25529064
Loukriz, Abdelhamid; Haddadi, Mourad; Messalti, Sabir
2016-05-01
Improvement of the efficiency of photovoltaic system based on new maximum power point tracking (MPPT) algorithms is the most promising solution due to its low cost and its easy implementation without equipment updating. Many MPPT methods with fixed step size have been developed. However, when atmospheric conditions change rapidly , the performance of conventional algorithms is reduced. In this paper, a new variable step size Incremental Conductance IC MPPT algorithm has been proposed. Modeling and simulation of different operational conditions of conventional Incremental Conductance IC and proposed methods are presented. The proposed method was developed and tested successfully on a photovoltaic system based on Flyback converter and control circuit using dsPIC30F4011. Both, simulation and experimental design are provided in several aspects. A comparative study between the proposed variable step size and fixed step size IC MPPT method under similar operating conditions is presented. The obtained results demonstrate the efficiency of the proposed MPPT algorithm in terms of speed in MPP tracking and accuracy. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Onboard Radar Processing Development for Rapid Response Applications
NASA Technical Reports Server (NTRS)
Lou, Yunling; Chien, Steve; Clark, Duane; Doubleday, Josh; Muellerschoen, Ron; Wang, Charles C.
2011-01-01
We are developing onboard processor (OBP) technology to streamline data acquisition on-demand and explore the potential of the L-band SAR instrument onboard the proposed DESDynI mission and UAVSAR for rapid response applications. The technology would enable the observation and use of surface change data over rapidly evolving natural hazards, both as an aid to scientific understanding and to provide timely data to agencies responsible for the management and mitigation of natural disasters. We are adapting complex science algorithms for surface water extent to detect flooding, snow/water/ice classification to assist in transportation/ shipping forecasts, and repeat-pass change detection to detect disturbances. We are near completion of the development of a custom FPGA board to meet the specific memory and processing needs of L-band SAR processor algorithms and high speed interfaces to reformat and route raw radar data to/from the FPGA processor board. We have also developed a high fidelity Matlab model of the SAR processor that is modularized and parameterized for ease to prototype various SAR processor algorithms targeted for the FPGA. We will be testing the OBP and rapid response algorithms with UAVSAR data to determine the fidelity of the products.
The failure of routine rapid HIV testing: a case study of improving low sensitivity in the field.
Wolpaw, Benjamin J; Mathews, Catherine; Chopra, Mickey; Hardie, Diana; de Azevedo, Virginia; Jennings, Karen; Lurie, Mark N
2010-03-22
The rapid HIV antibody test is the diagnostic tool of choice in low and middle-income countries. Previous evidence suggests that rapid HIV diagnostic tests may underperform in the field, failing to detect a substantial number of infections. A research study inadvertently discovered that a clinic rapid HIV testing process was failing to detect cases of established (high antibody titer) infection, exhibiting an estimated 68.7% sensitivity (95% CI [41.3%-89.0%]) over the course of the first three weeks of observation. The setting is a public service clinic that provides STI diagnosis and treatment in an impoverished, peri-urban community outside of Cape Town, South Africa. The researchers and local health administrators collaborated to investigate the cause of the poor test performance and make necessary corrections. The clinic changed the brand of rapid test being used and later introduced quality improvement measures. Observations were made of the clinic staff as they administered rapid HIV tests to real patients. Estimated testing sensitivity was calculated as the number of rapid HIV test positive individuals detected by the clinic divided by this number plus the number of PCR positive, highly reactive 3rd generation ELISA patients identified among those who were rapid test negative at the clinic. In the period of five months after the clinic made the switch of rapid HIV tests, estimated sensitivity improved to 93.5% (95% CI [86.5%-97.6%]), during which time observations of counselors administering tests at the clinic found poor adherence to the recommended testing protocol. Quality improvement measures were implemented and estimated sensitivity rose to 95.1% (95% CI [83.5%-99.4%]) during the final two months of full observation. Poor testing procedure in the field can lead to exceedingly low levels of rapid HIV test sensitivity, making it imperative that stringent quality control measures are implemented where they do not already exist. Certain brands of rapid-testing kits may perform better than others when faced with sub-optimal use.
NASA Astrophysics Data System (ADS)
Lee, Stephen R.; Kardos, Keith W.; Yearwood, Graham D.; Guillon, Geraldine B.; Kurtz, Lisa A.; Mokkapati, Vijaya K.
2008-04-01
Rapid, point of care (POC) testing has been increasingly deployed as an aid in the diagnosis of infectious disease, due to its ability to deliver rapid, actionable results. In the case of HIV, a number of rapid test devices have been FDA approved and CLIA-waived in order to enable diagnosis of HIV infection outside of traditional laboratory settings. These settings include STD clinics, community outreach centers and mobile testing units, as well as identifying HIV infection among pregnant women and managing occupational exposure to infection. The OraQuick ® rapid test platform has been widely used to identify HIV in POC settings, due to its simplicity, ease of use and the ability to utilize oral fluid as an alternative specimen to blood. More recently, a rapid test for antibodies to hepatitis C virus (HCV) has been developed on the same test platform which uses serum, plasma, finger-stick blood, venous blood and oral fluid. Clinical testing using this POC test device has shown that performance is equivalent to state of the art, laboratory based tests. These devices may be suitable for rapid field testing of blood and other body fluids for the presence of infectious agents.
[Microbiology--laboratory examinations for bacterias].
Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi
2002-11-01
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
Prasad, K J; Oberoi, J K; Goel, N; Wattal, C
2015-01-01
Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.
Eggman, Ashley A; Feaster, Daniel J; Leff, Jared A; Golden, Matthew R; Castellon, Pedro C; Gooden, Lauren; Matheson, Tim; Colfax, Grant N; Metsch, Lisa R; Schackman, Bruce R
2014-09-01
Rapid HIV testing in high-risk populations can increase the number of persons who learn their HIV status and avoid spending clinic resources to locate persons identified as HIV infected. We determined the cost to sexually transmitted disease (STD) clinics of point-of-care rapid HIV testing using data from 7 public clinics that participated in a randomized trial of rapid testing with and without brief patient-centered risk reduction counseling in 2010. Costs included counselor and trainer time, supplies, and clinic overhead. We applied national labor rates and test costs. We calculated median clinic start-up costs and mean cost per patient tested, and projected incremental annual costs of implementing universal rapid HIV testing compared with current testing practices. Criteria for offering rapid HIV testing and methods for delivering nonrapid test results varied among clinics before the trial. Rapid HIV testing cost an average of US $22/patient without brief risk reduction counseling and US $46/patient with counseling in these 7 clinics. Median start-up costs per clinic were US $1100 and US $16,100 without and with counseling, respectively. Estimated incremental annual costs per clinic of implementing universal rapid HIV testing varied by whether or not brief counseling is conducted and by current clinic testing practices, ranging from a savings of US $19,500 to a cost of US $40,700 without counseling and a cost of US $98,000 to US $153,900 with counseling. Universal rapid HIV testing in STD clinics with same-day results can be implemented at relatively low cost to STD clinics, if brief risk reduction counseling is not offered.
Elcock, Adrian H.
2013-01-01
Inclusion of hydrodynamic interactions (HIs) is essential in simulations of biological macromolecules that treat the solvent implicitly if the macromolecules are to exhibit correct translational and rotational diffusion. The present work describes the development and testing of a simple approach aimed at allowing more rapid computation of HIs in coarse-grained Brownian dynamics simulations of systems that contain large numbers of flexible macromolecules. The method combines a complete treatment of intramolecular HIs with an approximate treatment of the intermolecular HIs which assumes that the molecules are effectively spherical; all of the HIs are calculated at the Rotne-Prager-Yamakawa level of theory. When combined with Fixman’s Chebyshev polynomial method for calculating correlated random displacements, the proposed method provides an approach that is simple to program but sufficiently fast that it makes it computationally viable to include HIs in large-scale simulations. Test calculations performed on very coarse-grained models of the pyruvate dehydrogenase (PDH) E2 complex and on oligomers of ParM (ranging in size from 1 to 20 monomers) indicate that the method reproduces the translational diffusion behavior seen in more complete HI simulations surprisingly well; the method performs less well at capturing rotational diffusion but its discrepancies diminish with increasing size of the simulated assembly. Simulations of residue-level models of two tetrameric protein models demonstrate that the method also works well when more structurally detailed models are used in the simulations. Finally, test simulations of systems containing up to 1024 coarse-grained PDH molecules indicate that the proposed method rapidly becomes more efficient than the conventional BD approach in which correlated random displacements are obtained via a Cholesky decomposition of the complete diffusion tensor. PMID:23914146
Yeo, Seon-Ju; Huong, Dinh Thi; Hong, Nguyen Ngoc; Li, Chun-Ying; Choi, Kyunghan; Yu, Kyoungsik; Choi, Du-Young; Chong, Chom-Kyu; Choi, Hak Soo; Mallik, Shyam Kumar; Kim, Hak Sung; Sung, Haan Woo; Park, Hyun
2014-01-01
Great efforts have been made to develop robust signal-generating fluorescence materials which will help in improving the rapid diagnostic test (RDT) in terms of sensitivity and quantification. In this study, we developed coumarin-derived dendrimer-based fluorescent immunochromatographic strip test (FICT) assay with enhanced sensitivity as a quantitative diagnostic tool in typical RDT environments. The accuracy of the proposed FICT was compared with that of dot blot immunoassay techniques and conventional RDTs. Through conjugation of coumarin-derived dendrimers with latex beads, fluorescent emission covering broad output spectral ranges was obtained which provided a distinct advantage of easy discrimination of the fluorescent emission of the latex beads with a simple insertion of a long-pass optical filter away from the excitation wavelength. The newly developed FICT assay was able to detect 100 ng/10 μL of influenza A nucleoprotein (NP) antigen within 5 minutes, which corresponded to 2.5-fold higher sensitivity than that of the dot blot immunoassay or conventional RDTs. Moreover, the FICT assay was confirmed to detect at least four avian influenza A subtypes (H5N3, H7N1, H7N7, and H9N2). On applying the FICT to the clinical swab samples infected with respiratory viruses, our FICT assay was confirmed to differentiate influenza H1N1 infection from other respiratory viral diseases. These data demonstrate that the proposed FICT assay is able to detect zoonotic influenza A viruses with a high sensitivity, and it enables the quantitation of the infection intensity by providing the numerical diagnostic values; thus demonstrating enhanced detectability of influenza A viruses.
Ulanova, Lilia S; Pinheiro, Marina; Vibe, Carina; Nunes, Claudia; Misaghian, Dorna; Wilson, Steven; Zhu, Kaizheng; Fenaroli, Federico; Winther-Larsen, Hanne C; Reis, Salette; Griffiths, Gareth
2017-06-19
We tested the efficiency of 2 different antibiotics, rifampicin and oxolinic acid, against an established infection caused by fish pathogen Francisella noatunensis ssp. orientalis (F.n.o.) in zebrafish. The drugs were tested in the free form as well as encapsulated into biodegradable nanoparticles, either polylactic-co-glycolic acid (PLGA) nanoparticles or nanostructured lipid carriers. The most promising therapies were PLGA-rifampicin nanoparticles and free oxolinic acid; the PLGA nanoparticles significantly delayed embryo mortality while free oxolinic acid prevented it. Encapsulation of rifampicin in both PLGA and nanostructured lipid carriers enhanced its efficiency against F.n.o. infection relative to the free drug. We propose that the zebrafish model is a robust, rapid system for initial testing of different treatments of bacterial diseases important for aquaculture.
A rapid low-cost high-density DNA-based multi-detection test for routine inspection of meat species.
Lin, Chun Chi; Fung, Lai Ling; Chan, Po Kwok; Lee, Cheuk Man; Chow, Kwok Fai; Cheng, Shuk Han
2014-02-01
The increasing occurrence of food frauds suggests that species identification should be part of food authentication. Current molecular-based species identification methods have their own limitations or drawbacks, such as relatively time-consuming experimental steps, expensive equipment and, in particular, these methods cannot identify mixed species in a single experiment. This project proposes an improved method involving PCR amplification of the COI gene and detection of species-specific sequences by hybridisation. Major innovative breakthrough lies in the detection of multiple species, including pork, beef, lamb, horse, cat, dog and mouse, from a mixed sample within a single experiment. The probes used are species-specific either in sole or mixed species samples. As little as 5 pg of DNA template in the PCR is detectable in the proposed method. By designing species-specific probes and adopting reverse dot blot hybridisation and flow-through hybridisation, a low-cost high-density DNA-based multi-detection test suitable for routine inspection of meat species was developed. © 2013.
Design Considerations for Proposed Fermilab Integrable RCS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldred, Jeffrey; Valishev, Alexander
2017-03-02
Integrable optics is an innovation in particle accelerator design that provides strong nonlinear focusing while avoiding parametric resonances. One promising application of integrable optics is to overcome the traditional limits on accelerator intensity imposed by betatron tune-spread and collective instabilities. The efficacy of high-intensity integrable accelerators will be undergo comprehensive testing over the next several years at the Fermilab Integrable Optics Test Accelerator (IOTA) and the University of Maryland Electron Ring (UMER). We propose an integrable Rapid-Cycling Synchrotron (iRCS) as a replacement for the Fermilab Booster to achieve multi-MW beam power for the Fermilab high-energy neutrino program. We provide amore » overview of the machine parameters and discuss an approach to lattice optimization. Integrable optics requires arcs with integer-pi phase advance followed by drifts with matched beta functions. We provide an example integrable lattice with features of a modern RCS - long dispersion-free drifts, low momentum compaction, superperiodicity, chromaticity correction, separate-function magnets, and bounded beta functions.« less
The Design and Semi-Physical Simulation Test of Fault-Tolerant Controller for Aero Engine
NASA Astrophysics Data System (ADS)
Liu, Yuan; Zhang, Xin; Zhang, Tianhong
2017-11-01
A new fault-tolerant control method for aero engine is proposed, which can accurately diagnose the sensor fault by Kalman filter banks and reconstruct the signal by real-time on-board adaptive model combing with a simplified real-time model and an improved Kalman filter. In order to verify the feasibility of the method proposed, a semi-physical simulation experiment has been carried out. Besides the real I/O interfaces, controller hardware and the virtual plant model, semi-physical simulation system also contains real fuel system. Compared with the hardware-in-the-loop (HIL) simulation, semi-physical simulation system has a higher degree of confidence. In order to meet the needs of semi-physical simulation, a rapid prototyping controller with fault-tolerant control ability based on NI CompactRIO platform is designed and verified on the semi-physical simulation test platform. The result shows that the controller can realize the aero engine control safely and reliably with little influence on controller performance in the event of fault on sensor.
[Analysis on willingness to pay for HIV antibody saliva rapid test and related factors].
Li, Junjie; Huo, Junli; Cui, Wenqing; Zhang, Xiujie; Hu, Yi; Su, Xingfang; Zhang, Wanyue; Li, Youfang; Shi, Yuhua; Jia, Manhong
2015-02-01
To understand the willingness to pay for HIV antibody saliva rapid test and its influential factors among people seeking counsel and HIV test, STD clinic patients, university students, migrant people, female sex workers (FSWs), men who have sex with men (MSM) and injecting drug users (IDUs). An anonymous questionnaire survey was conducted among 511 subjects in the 7 groups selected by different sampling methods, and 509 valid questionnaires were collected. The majority of subjects were males (54.8%) and aged 20-29 years (41.5%). Among the subjects, 60.3% had education level of high school or above, 55.4% were unmarried, 37.3% were unemployed, 73.3% had monthly expenditure <2 000 Yuan RMB, 44.2% had received HIV test, 28.3% knew HIV saliva test, 21.0% were willing to receive HIV saliva test, 2.0% had received HIV saliva test, only 1.0% had bought HIV test kit for self-test, and 84.1% were willing to pay for HIV antibody saliva rapid test. Univariate logistic regression analysis indicated that subject group, age, education level, employment status, monthly expenditure level, HIV test experience and willingness to receive HIV saliva test were correlated statistically with willingness to pay for HIV antibody saliva rapid test. Multivariate logistic regression analysis showed that subject group and monthly expenditure level were statistically correlated with willingness to pay for HIV antibody saliva rapid test. The willingness to pay for HIV antibody saliva rapid test and acceptable price of HIV antibody saliva rapid test varied in different areas and populations. Different populations may have different willingness to pay for HIV antibody saliva rapid test;the affordability of the test could influence the willingness to pay for the test.
Hammouda, Mohammed E A; Abu El-Enin, Mohamed A; El-Sherbiny, Dina T; El-Wasseef, Dalia R; El-Ashry, Saadia M
2015-01-01
A rapid high-performance liquid chromatography procedure for analytical quality control of mixture containing enalapril maleate (ENM) and hydrochlorothiazide (HCT) in their pharmaceutical preparations was developed using a microemulsion as an eluent. The separation was performed on a column packed with cyano-bonded stationary phase adopting UV detection at 210 nm using a flow rate of 1 mL/min. The optimized microemulsion mobile phase consisted of 0.2 M sodium dodecyl sulfate, 1% octanol, 10% n-propanol and 0.3% triethylamine in 0.02 M phosphoric acid, and pH was adjusted at 3.5. The proposed method was found to be linear over the concentration ranges 1-100 and 0.05-5 μg/mL for ENM and HCT, respectively with a correlation coefficient of 0.9999 for both drugs. The developed method was validated in terms of specificity, linearity, lower limit of quantification, lower limit of detection, precision and accuracy. The proposed method is rapid (5 min), reproducible (relative standard deviation <2.0%) and achieves a satisfactory resolution between ENM and HCT (resolution factor = 3.62). The mean recoveries of the analytes in tablets were in agreement with those obtained from a comparison method, as revealed by statistical analysis of the obtained results using Student's t-test and the variance ratio F-test. © The Author [2014]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Abdul Kamal Nazer, Meeran Mohideen; Hameed, Abdul Rahman Shahul; Riyazuddin, Patel
2004-01-01
A simple and rapid potentiometric method for the estimation of ascorbic acid in pharmaceutical dosage forms has been developed. The method is based on treating ascorbic acid with iodine and titration of the iodide produced equivalent to ascorbic acid with silver nitrate using Copper Based Mercury Film Electrode (CBMFE) as an indicator electrode. Interference study was carried to check possible interference of usual excipients and other vitamins. The precision and accuracy of the method was assessed by the application of lack-of-fit test and other statistical methods. The results of the proposed method and British Pharmacopoeia method were compared using F and t-statistical tests of significance.
Anti-disturbance rapid vibration suppression of the flexible aerial refueling hose
NASA Astrophysics Data System (ADS)
Su, Zikang; Wang, Honglun; Li, Na
2018-05-01
As an extremely dangerous phenomenon in autonomous aerial refueling (AAR), the flexible refueling hose vibration caused by the receiver aircraft's excessive closure speed should be suppressed once it appears. This paper proposed a permanent magnet synchronous motor (PMSM) based refueling hose servo take-up system for the vibration suppression of the flexible refueling hose. A rapid back-stepping based anti-disturbance nonsingular fast terminal sliding mode (NFTSM) control scheme with a specially established finite-time convergence NFTSM observer is proposed for the PMSM based hose servo take-up system under uncertainties and disturbances. The unmeasured load torque and other disturbances in the PMSM system are reconstituted by the NFTSM observer and to be compensated during the controller design. Then, with the back-stepping technique, a rapid anti-disturbance NFTSM controller is proposed for the PMSM angular tracking to improve the tracking error convergence speed and tracking precision. The proposed vibration suppression scheme is then applied to PMSM based hose servo take-up system for the refueling hose vibration suppression in AAR. Simulation results show the proposed scheme can suppress the hose vibration rapidly and accurately even the system is exposed to strong uncertainties and probe position disturbances, it is more competitive in tracking accuracy, tracking error convergence speed and robustness.
Rapid C-reactive protein and white cell tests decrease cost and shorten emergency visits.
Kokko, Eeva; Korppi, Matti; Helminen, Merja; Hutri-Kähönen, Nina
2014-10-01
Elevated white blood cells (WBC) in blood and C-reactive protein (CRP) in serum are often used as non-specific markers for bacterial etiology of infection in children. The aim of the present study was to evaluate how rapid WBC and CRP testing influences patient flow and cost in the pediatric emergency room (ER). This study was a retrospective chart review. In all, 166 children who were treated during 3 months in the ER of a children's hospital, and in whom rapid tests for WBC and CRP were done, were included. The association between rapid testing and length of ER stay was evaluated, and the cost of rapid tests was compared with the corresponding cost if done in the hospital laboratory. Median ER stay was 147.5 min, if no examinations other than rapid CRP and WBC tests were done and if no emergency treatment was given, compared with 201.5 min for laboratory tests or emergency treatment given (P < 0.001). The respective figures were 142.5 min and 179.5 min in those 96 children discharged home (P = 0.003). The cost of rapid testing was only 41.5% of the corresponding laboratory cost. The simultaneous rapid testing of CRP and WBC in children with presumable infection decreased cost and shortened the length of ER stay, if no other examinations or emergency treatment were needed. The cost of rapid testing was less than half of the corresponding cost in laboratory. © 2014 Japan Pediatric Society.
Naccarato, Attilio; Gionfriddo, Emanuela; Elliani, Rosangela; Sindona, Giovanni; Tagarelli, Antonio
2014-10-30
The analysis of characteristic urinary acidic markers such as glutaric, 3-hydroxyglutaric, 2-hydroxyglutaric, adipic, suberic, sebacic, ethylmalonic, 3-hydroxyisovaleric and isobutyric acid constitutes the recommended follow-up testing procedure for glutaric acidemia type 1 (GA-1) and type 2 (GA-2). The goal of the work herein presented is the development of a fast and simple method for the quantification of these biomarkers in human urine. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) afterward a rapid derivatization of acidic moieties by propyl chloroformate, propanol and pyridine. Trueness and precision of the proposed protocol, tested at 5, 30 and 80mgl -1 , provided satisfactory values: recoveries were in the range between 72% and 116% and the relative standard deviations (RSD%) were between 0.9% and 18% (except for isobutyric acid at 5mgl -1 ). The LOD values achieved by the proposed method ranged between 1.0 and 473μgl -1 . Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Strub, P. Ted
1991-01-01
The overall goal of this project was to increase our understanding of processes which determine the temporally varying distributions of surface chlorophyll pigment concentration and surface temperature in the California Current System (CCS) on the time-scale of 'events', i.e., several days to several weeks. We also proposed to investigate seasonal and regional differences in these events. Additionally, we proposed to evaluate methods of estimating surface velocities and horizontal transport of pigment and heat from sequences of AVHRR and CZCS images. The four specific objectives stated in the original proposal were to: (1) test surface current estimates made from sequences of both SST and color images using variations of the statistical method of Emery et al. (1986) and estimate the uncertainties in these satellite-derived surface currents; (2) characterize the spatial and temporal relationships of chlorophyll and temperature in rapidly evolving features for which adequate imagery exist and evaluate the contribution of these events to monthly and seasonal averages; (3) use the methods tested in (1) to determine the nature of the velocity fields in the CCS; and (4) compare the currents, temperature, and currents in different seasons and in different geographic regions.
Rapid HIV-1 testing during labor: a multicenter study.
Bulterys, Marc; Jamieson, Denise J; O'Sullivan, Mary Jo; Cohen, Mardge H; Maupin, Robert; Nesheim, Steven; Webber, Mayris P; Van Dyke, Russell; Wiener, Jeffrey; Branson, Bernard M
2004-07-14
Timely testing of women in labor with undocumented human immunodeficiency virus (HIV) status could enable immediate provision of antiretroviral prophylaxis. To determine the feasibility and acceptance of rapid HIV testing among women in labor and to assess rapid HIV assay performance. The Mother-Infant Rapid Intervention At Delivery (MIRIAD) study implemented 24-hour counseling and voluntary rapid HIV testing for women in labor at 16 US hospitals from November 16, 2001, through November 15, 2003. A rapid HIV-1 antibody test for whole blood was used. Acceptance of HIV testing; sensitivity, specificity, and predictive value of the rapid test; time from blood collection to patient notification of results. There were 91,707 visits to the labor and delivery units in the study, 7381 of which were by eligible women without documentation of HIV testing. Of these, 5744 (78%) women were approached for rapid HIV testing and 4849 (84%) consented. HIV-1 test results were positive for 34 women (prevalence = 7/1000). Sensitivity and specificity of the rapid test were 100% and 99.9%, respectively; positive predictive value was 90% compared with 76% for enzyme immunoassay (EIA). Factors independently associated with higher test acceptance included younger age, being black or Hispanic, gestational age less than 32 weeks, and having had no prenatal care. Lower acceptance was associated with being admitted between 4 pm and midnight, particularly on Friday nights, but this may be explained in part by fewer available personnel. Median time from blood collection to patient notification of result was 66 minutes (interquartile range, 45-120 minutes), compared with 28 hours for EIA (P<.001). Rapid HIV testing is feasible and delivers accurate and timely test results for women in labor. It provides HIV-positive women prompt access to intrapartum and neonatal antiretroviral prophylaxis, proven to reduce perinatal HIV transmission, and may be particularly applicable to higher-risk populations.
Rich-burn, flame-assisted fuel cell, quick-mix, lean-burn (RFQL) combustor and power generation
NASA Astrophysics Data System (ADS)
Milcarek, Ryan J.; Ahn, Jeongmin
2018-03-01
Micro-tubular flame-assisted fuel cells (mT-FFC) were recently proposed as a modified version of the direct flame fuel cell (DFFC) operating in a dual chamber configuration. In this work, a rich-burn, quick-mix, lean-burn (RQL) combustor is combined with a micro-tubular solid oxide fuel cell (mT-SOFC) stack to create a rich-burn, flame-assisted fuel cell, quick-mix, lean-burn (RFQL) combustor and power generation system. The system is tested for rapid startup and achieves peak power densities after only 35 min of testing. The mT-FFC power density and voltage are affected by changes in the fuel-lean and fuel-rich combustion equivalence ratio. Optimal mT-FFC performance favors high fuel-rich equivalence ratios and a fuel-lean combustion equivalence ratio around 0.80. The electrical efficiency increases by 150% by using an intermediate temperature cathode material and improving the insulation. The RFQL combustor and power generation system achieves rapid startup, a simplified balance of plant and may have applications for reduced NOx formation and combined heat and power.
Mycoplasma mastitis in cattle: To cull or not to cull.
Nicholas, Robin A J; Fox, Larry K; Lysnyansky, Inna
2016-10-01
Bovine mastitis caused by mycoplasmas, in particular Mycoplasma bovis, is a major problem for milk production and animal welfare in large dairy herds in the USA and a serious, although sporadic, disease in Europe and the Middle East. It causes severe damage to the udder of cattle and is largely untreatable by chemotherapy. Mycoplasma mastitis has a distinct epidemiology and a unique set of risk factors, the most important of which is large herd size. The disease is often self-limiting, disappearing within months of outbreaks, sometimes without deliberate intervention. Improved molecular diagnostic tests are leading to more rapid detection of mycoplasmas. Typing tests, such as multi-locus sequence typing, can help trace the source of outbreaks. An approach to successful control is proposed, which involves regular monitoring and rapid segregation or culling of infected cows. Serious consideration should be given by owners of healthy dairy herds to the purchase of M. bovis-free replacements. Increased cases of disease could occur in Europe and Israel if the trend for larger dairy herds continues. Copyright © 2016 Elsevier Ltd. All rights reserved.
Murakoshi, Kazushi; Mizuno, Junya
2004-11-01
In order to rapidly follow unexpected environmental changes, we propose a parameter control method in reinforcement learning that changes each of learning parameters in appropriate directions. We determine each appropriate direction on the basis of relationships between behaviors and neuromodulators by considering an emergency as a key word. Computer experiments show that the agents using our proposed method could rapidly respond to unexpected environmental changes, not depending on either two reinforcement learning algorithms (Q-learning and actor-critic (AC) architecture) or two learning problems (discontinuous and continuous state-action problems).
Petrova, Anastasiia; Dar'in, Dmitriy; Ivanov, Aleхander; Moskvin, Leonid; Ishimatsu, Ryoichi; Nakano, Koji; Imato, Toshihiko; Bulatov, Andrey
2016-10-01
A mesofluidic platform (MP) with fluorescence detection based on a stepwise injection analysis (SWIA) was used for the determination of curcumin in biologically active supplements and food spices. The main units of the MP are a mixing chamber (MC) and an optical channel with a quartz capillary inside. The MC provides rapid and complete mixing solutions by gas bubbling. The proposed method is based on the new rapid and sensitive reaction of curcumin with a fluorescence reagent - 4-(2,3,3-trimethyl-3H-indolium-1-yl)butane-1-sulfonate (TIBS). The fluorescence intensity of TIBS is greatly quenched in the presence of curcumin in an alkaline medium. The linear range was from 1 to 10µM of curcumin, and the limit of detection, calculated as 3σ of a blank test (n=5), was found to be 0.3µM. The sample throughput was 24h(-1). The proposed method was successfully applied for the determination of curcumin in biologically active supplements and samples of food spices. The obtained data were in good agreement with those measured by a HPLC-UV method. Copyright © 2016 Elsevier B.V. All rights reserved.
Bowman, Howard; Filetti, Marco; Janssen, Dirk; Su, Li; Alsufyani, Abdulmajeed; Wyble, Brad
2013-01-01
We propose a novel deception detection system based on Rapid Serial Visual Presentation (RSVP). One motivation for the new method is to present stimuli on the fringe of awareness, such that it is more difficult for deceivers to confound the deception test using countermeasures. The proposed system is able to detect identity deception (by using the first names of participants) with a 100% hit rate (at an alpha level of 0.05). To achieve this, we extended the classic Event-Related Potential (ERP) techniques (such as peak-to-peak) by applying Randomisation, a form of Monte Carlo resampling, which we used to detect deception at an individual level. In order to make the deployment of the system simple and rapid, we utilised data from three electrodes only: Fz, Cz and Pz. We then combined data from the three electrodes using Fisher's method so that each participant was assigned a single p-value, which represents the combined probability that a specific participant was being deceptive. We also present subliminal salience search as a general method to determine what participants find salient by detecting breakthrough into conscious awareness using EEG. PMID:23372697
Kelbe, David; Oak Ridge National Lab.; van Aardt, Jan; ...
2016-10-18
Terrestrial laser scanning has demonstrated increasing potential for rapid comprehensive measurement of forest structure, especially when multiple scans are spatially registered in order to reduce the limitations of occlusion. Although marker-based registration techniques (based on retro-reflective spherical targets) are commonly used in practice, a blind marker-free approach is preferable, insofar as it supports rapid operational data acquisition. To support these efforts, we extend the pairwise registration approach of our earlier work, and develop a graph-theoretical framework to perform blind marker-free global registration of multiple point cloud data sets. Pairwise pose estimates are weighted based on their estimated error, in ordermore » to overcome pose conflict while exploiting redundant information and improving precision. The proposed approach was tested for eight diverse New England forest sites, with 25 scans collected at each site. Quantitative assessment was provided via a novel embedded confidence metric, with a mean estimated root-mean-square error of 7.2 cm and 89% of scans connected to the reference node. Lastly, this paper assesses the validity of the embedded multiview registration confidence metric and evaluates the performance of the proposed registration algorithm.« less
Galetta, Matthew S; Galetta, Kristin M; McCrossin, Jim; Wilson, James A; Moster, Stephen; Galetta, Steven L; Balcer, Laura J; Dorshimer, Gary W; Master, Christina L
2013-05-15
The Sports Concussion Assessment Tool 2 (SCAT2) and King-Devick (K-D) tests have both been proposed as sideline tools to detect sports-related concussion. We performed an exploratory analysis to determine the relation of SCAT2 components, particularly the Standardized Assessment of Concussion (SAC), to K-D test scores in a professional ice hockey team cohort during pre-season baseline testing. We also examined changes in scores for two athletes who developed concussion and had rinkside testing. A modified SCAT2 (no balance testing) and the K-D test, a brief measure of rapid number naming, were administered to 27 members of a professional ice hockey team during the 2011-2012 pre-season. Athletes with concussion also underwent rinkside testing. Lower (worse) scores for the SCAT2 SAC Immediate Memory Score and the overall SAC score were associated with greater (worse) times required to complete the K-D test at baseline. On average, for every 1-point reduction in SAC Immediate Memory Score, we found a corresponding increase (worsening) of K-D time score of 7.3s (95% CI 4.9, 9.7, p<0.001, R(2)=0.62, linear regression, accounting for age). For the overall SAC score, 1-point reductions were associated with K-D score worsening of 2.2s (95% CI 0.6, 3.8, p=0.01, R(2)=0.25, linear regression). In two players tested rinkside immediately following concussion, K-D test scores worsened from baseline by 4.2 and 6.4s. These athletes had no differences found for SCAT2 SAC components, but reported symptoms of concussion. In this study of professional athletes, scores for the K-D test, a measure for which saccadic (fast) eye movements are required for the task of rapid number naming, were associated with reductions in Immediate Memory at a pre-season baseline. Both working memory and saccadic eye movements share closely related anatomical structures, including the dorsolateral prefrontal cortex (DLPFC). A composite of brief rapid sideline tests, including SAC and K-D (and balance testing for non-ice hockey sports), is likely to provide an effective clinical tool to assess the athlete with suspected concussion. Copyright © 2013 Elsevier B.V. All rights reserved.
The Direct Georeferencing Application and Performance Analysis of Uav Helicopter in Gcp-Free Area
NASA Astrophysics Data System (ADS)
Lo, C. F.; Tsai, M. L.; Chiang, K. W.; Chu, C. H.; Tsai, G. J.; Cheng, C. K.; El-Sheimy, N.; Ayman, H.
2015-08-01
There are many disasters happened because the weather changes extremely in these years. To facilitate applications such as environment detection or monitoring becomes very important. Therefore, the development of rapid low cost systems for collecting near real-time spatial information is very critical. Rapid spatial information collection has become an emerging trend for remote sensing and mapping applications. This study develops a Direct Georeferencing (DG) based Unmanned Aerial Vehicle (UAV) helicopter photogrammetric platform where an Inertial Navigation System (INS)/Global Navigation Satellite System (GNSS) integrated Positioning and Orientation System (POS) system is implemented to provide the DG capability of the platform. The performance verification indicates that the proposed platform can capture aerial images successfully. A flight test is performed to verify the positioning accuracy in DG mode without using Ground Control Points (GCP). The preliminary results illustrate that horizontal DG positioning accuracies in the x and y axes are around 5 meter with 100 meter flight height. The positioning accuracy in the z axis is less than 10 meter. Such accuracy is good for near real-time disaster relief. The DG ready function of proposed platform guarantees mapping and positioning capability even in GCP free environments, which is very important for rapid urgent response for disaster relief. Generally speaking, the data processing time for the DG module, including POS solution generalization, interpolation, Exterior Orientation Parameters (EOP) generation, and feature point measurements, is less than 1 hour.
Del Fiol, Guilherme; Hanseler, Haley; Crouch, Barbara Insley; Cummins, Mollie R.
2016-01-01
Summary Background Health information exchange (HIE) between Poison Control Centers (PCCs) and Emergency Departments (EDs) could improve care of poisoned patients. However, PCC information systems are not designed to facilitate HIE with EDs; therefore, we are developing specialized software to support HIE within the normal workflow of the PCC using user-centered design and rapid prototyping. Objective To describe the design of an HIE dashboard and the refinement of user requirements through rapid prototyping. Methods Using previously elicited user requirements, we designed low-fidelity sketches of designs on paper with iterative refinement. Next, we designed an interactive high-fidelity prototype and conducted scenario-based usability tests with end users. Users were asked to think aloud while accomplishing tasks related to a case vignette. After testing, the users provided feedback and evaluated the prototype using the System Usability Scale (SUS). Results Survey results from three users provided useful feedback that was then incorporated into the design. After achieving a stable design, we used the prototype itself as the specification for development of the actual software. Benefits of prototyping included having 1) subject-matter experts heavily involved with the design; 2) flexibility to make rapid changes, 3) the ability to minimize software development efforts early in the design stage; 4) rapid finalization of requirements; 5) early visualization of designs; 6) and a powerful vehicle for communication of the design to the programmers. Challenges included 1) time and effort to develop the prototypes and case scenarios; 2) no simulation of system performance; 3) not having all proposed functionality available in the final product; and 4) missing needed data elements in the PCC information system. PMID:27081404
NASA Astrophysics Data System (ADS)
Dehbozorgi, Mohammad Reza
2000-10-01
Improvements in power system reliability have always been of interest to both power companies and customers. Since there are no sizable electrical energy storage elements in electrical power systems, the generated power should match the load demand at any given time. Failure to meet this balance may cause severe system problems, including loss of generation and system blackouts. This thesis proposes a methodology which can respond to either loss of generation or loss of load. It is based on switching of electric water heaters using power system frequency as the controlling signal. The proposed methodology encounters, and the thesis has addressed, the following associated problems. The controller must be interfaced with the existing thermostat control. When necessary to switch on loads, the water in the tank should not be overheated. Rapid switching of blocks of load, or chattering, has been considered. The contributions of the thesis are: (A) A system has been proposed which makes a significant portion of the distributed loads connected to a power system to behave in a predetermined manner to improve the power system response during disturbances. (B) The action of the proposed system is transparent to the customers. (C) The thesis proposes a simple analysis for determining the amount of such loads which might be switched and relates this amount to the size of the disturbances which can occur in the utility. (D) The proposed system acts without any formal communication links, solely using the embedded information present system-wide. (E) The methodology of the thesis proposes switching of water heater loads based on a simple, localized frequency set-point controller. The thesis has identified the consequent problem of rapid switching of distributed loads, which is referred to as chattering. (F) Two approaches have been proposed to reduce chattering to tolerable levels. (G) A frequency controller has been designed and built according to the specifications required to switch electric water heater loads in response to power system disturbances. (H) A cost analysis for building and installing the distributed frequency controller has been carried out. (I) The proposed equipment and methodology has been implemented and tested successfully. (Abstract shortened by UMI.)
Zhang, Dapeng; Qi, Jinlei; Fu, Xiaojing; Meng, Sining; Li, Chengmei; Sun, Jiangping
2015-05-01
We sought to describe the advantage of rapid tests over ELISA tests in community-based screening for HIV among men who have sex with men (MSM) in urban areas of China. Data of 31,406 screening tests conducted over six months in 2011 among MSM across 12 areas were analyzed to compare the differences between those receiving rapid testing and ELISA. Rapid tests accounted for 45.8% of these screening tests. The rate of being screened positive was 7.2% among rapid tests and 5.3% for ELISA tests (χ(2 )= 49.161, p < 0.001). This advantage of rapid test in HIV case finding persisted even when socio-demographic, behavioural, screening recruitment channel and city were controlled for in logistic regression (exp[beta] = 1.42, p < 0.001, 95% CI = 1.27,1.59). MSM who received rapid tests, compared with those tested by ELISA, were less likely to use condoms during last anal sex (50.8% vs. 72.3%, χ(2 )= 1706.146, p < 0.001), more likely to have multiple sex partners (55.7% vs. 49.5%, χ(2 )= 238.188, p < 0.001) and less likely to have previously undergone HIV testing (38.8% vs. 54.7%, χ(2 )= 798.476, p < 0.001). These results demonstrate the robustness of the advantage of rapid tests over traditional ELISA tests in screening for MSM with HIV infection in cooperation with community-based organizations in urban settings in China. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.
Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H
2015-08-01
In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.
Research of x-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes
NASA Astrophysics Data System (ADS)
Wang, Junfeng; Miao, Changyun; Wang, Wei; Lu, Xiaocui
2008-03-01
An X-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes is researched in the paper. The principle of X-ray nondestructive testing (NDT) is analyzed, the general scheme of the X-ray nondestructive testing system is proposed, and the nondestructive detector for high-speed running conveyor belt with steel wire ropes is developed. The hardware of system is designed with Xilinx's VIRTEX-4 FPGA that embeds PowerPC and MAC IP core, and its network communication software based on TCP/IP protocol is programmed by loading LwIP to PowerPC. The nondestructive testing of high-speed conveyor belt with steel wire ropes and network transfer function are implemented. It is a strong real-time system with rapid scanning speed, high reliability and remotely nondestructive testing function. The nondestructive detector can be applied to the detection of product line in industry.
Rapidity dependence of proton cumulants and correlation functions
Bzdak, Adam; Koch, Volker
2017-11-13
The dependence of multiproton correlation functions and cumulants on the acceptance in rapidity and transverse momentum is studied. Here, we found that the preliminary data of various cumulant ratios are consistent, within errors, with rapidity and transverse momentum-independent correlation functions. But, rapidity correlations which moderately increase with rapidity separation between protons are slightly favored. We propose to further explore the rapidity dependence of multiparticle correlation functions by measuring the dependence of the integrated reduced correlation functions as a function of the size of the rapidity window.
Rapidity dependence of proton cumulants and correlation functions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bzdak, Adam; Koch, Volker
The dependence of multiproton correlation functions and cumulants on the acceptance in rapidity and transverse momentum is studied. Here, we found that the preliminary data of various cumulant ratios are consistent, within errors, with rapidity and transverse momentum-independent correlation functions. But, rapidity correlations which moderately increase with rapidity separation between protons are slightly favored. We propose to further explore the rapidity dependence of multiparticle correlation functions by measuring the dependence of the integrated reduced correlation functions as a function of the size of the rapidity window.
Nair, Dina; Navneethapandian, Pooranaganga D; Tripathy, Jaya Prasad; Harries, Anthony D; Klinton, Joel S; Watson, Basilea; Sivaramakrishnan, Gomathi N; Reddy, Devarajulu S; Murali, Lakshmi; Natrajan, Mohan; Swaminathan, Soumya
2016-09-01
India is replacing culture and drug sensitivity testing (CDST) with rapid molecular tests for diagnosing MDR-TB. We assessed the impact of rapid tests on time to initiation of treatment and outcomes in patients with MDR-TB compared with CDST. A retrospective cohort study involving MDR-TB patients from six districts in Tamil Nadu state, who underwent CDST (2010-2011) and rapid tests (2012-2013). There were 135 patients in the CDST group and 389 in the rapid diagnostic test group. Median time from sputum receipt at the laboratory to initiation of MDR-TB treatment was 130 days (IQR 75-213) in the CDST group and 22 days (IQR 14-38) in the rapid diagnostic test group (p<0.001). Overall treatment success was 30% with CDST and 41% with rapid tests (p<0.05), but there was high loss to follow-up >30% in both groups and missing data were higher in CDST (13%) compared with rapid tests (3%). There were significantly higher risks of unfavourable treatment outcomes in males (aRR 1.3, 95% CI 1.1-1.5) and those with treatment initiation delays >30 days (aRR 1.3, 95% CI 1.0-1.6). Rapid molecular diagnostic tests shortened the time to initiate treatment which was associated with reduced unfavourable outcomes in MDR-TB patients. This supports the policy to scale up these tests in India. © The Author 2016. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Towards a Tool for Malaria Supply Chain Management Improvement in Rural Ghana.
Carlo, Lorena; Bakken, Suzanne; Mamykina, Lena; Kodie, Richmond; Kanter, Andrew S
2015-01-01
The maintenance of adequate quantities of antimalarial medicines and rapid diagnostic tests (RDTs) at health facilities in rural areas of sub-Saharan Africa is a challenging task because of poor supply chain management. Antimalarial stock-outs in the communities could lead patients (that need to travel long distances to get medications) to remain untreated, develop severe malaria and die. A prototype to improve the management of health commodities in rural Ghana through the visualization of current stock levels and the forecasting of commodities is proposed.
Load Bearing Equipment for Bone and Muscle Project
NASA Technical Reports Server (NTRS)
Terrier, Douglas; Clayton, Ronald G.; Shackelford, Linda
2015-01-01
Axial skeletal loads coupled with muscle torque forces around joints maintain bone. Astronauts working in pairs to exercise can provide high eccentric loads for each other that are most effective. A prototype of load bearing equipment that will allow astronauts to perform exercises using each other for counter force generation in a controlled fashion and provide eccentric overload is proposed. A frame and attachments that can be rapidly assembled for use and easily stored will demonstrate feasibility of a design that can be adapted for ISS testing and Orion use.
Perception of non-verbal auditory stimuli in Italian dyslexic children.
Cantiani, Chiara; Lorusso, Maria Luisa; Valnegri, Camilla; Molteni, Massimo
2010-01-01
Auditory temporal processing deficits have been proposed as the underlying cause of phonological difficulties in Developmental Dyslexia. The hypothesis was tested in a sample of 20 Italian dyslexic children aged 8-14, and 20 matched control children. Three tasks of auditory processing of non-verbal stimuli, involving discrimination and reproduction of sequences of rapidly presented short sounds were expressly created. Dyslexic subjects performed more poorly than control children, suggesting the presence of a deficit only partially influenced by the duration of the stimuli and of inter-stimulus intervals (ISIs).
Gypsum-wallboard formaldehyde-sorption model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silberstein, S.
1989-11-01
Gypsum wallboard was shown to absorb formaldehyde in a prototype house and in a measuring chamber, as reported previously by researchers at Oak Ridge National Laboratory (ORNL). Also as reported previously, formaldehyde concentrations attained equilibrium in two phases in response to a change in the air exchange rate or to the removal of the formaldehyde source. A rapid initial phase was followed by a slow phase lasting several days. A formaldehyde sorption model that accounts for the biphasic concentration pattern is presented here. Experiments for testing the predictability of the model are proposed.
Johansson, Karin; Karlsson, Hanna; Norén, Torbjörn
2016-11-01
Diagnostic testing for Clostridium difficile infection (CDI) has, in recent years, seen the introduction of rapid dual-EIA (enzyme immunoassay) tests combining species-specific glutamate dehydrogenase (GDH) with toxin A/B. In a prospective study, we compared the C. DIFF Quik Chek Complete test to a combination of selective culture (SC) and loop-mediated isothermal amplification (LAMP) of the toxin A gene. Of 419 specimens, 68 were positive in SC including 62 positive in LAMP (14.7%). The combined EIA yielded 82 GDH positives of which 47 were confirmed toxin A/B positive (11%) corresponding to a sensitivity and specificity of 94% for GDH EIA compared to SC and for toxin A/B EIA a sensitivity of 71% and a specificity of 99% compared to LAMP. Twenty different PCR ribotypes were evenly distributed except for UK 081 where only 25% were toxin A/B positive compared to LAMP. We propose a primary use of a combined GDH toxin A/B EIA permitting a sensitive 1-h result of 379 of 419 (90%, all negatives plus GDH and toxin EIA positives) referred specimens. The remaining 10% being GDH positive should be tested for toxin A/B gene on the same day and positive results left to a final decision by the physician. © 2016 APMIS. Published by John Wiley & Sons Ltd.
Antenatal noninvasive DNA testing: clinical experience and impact.
Ferres, Millie A; Hui, Lisa; Bianchi, Diana W
2014-08-01
Nearly two decades ago, the discovery of circulating cell-free fetal DNA in maternal blood created a paradigm shift in prenatal testing. Recent advances in DNA sequencing technology have facilitated the rapid translation of DNA-based testing into clinical antenatal care. In this review, we summarize the technical approaches and current clinical applications of noninvasive testing using cell-free DNA in maternal plasma. We discuss the impact of these tests on clinical care, outline proposed integration models, and suggest future directions for the field. The use of cell-free DNA in maternal blood for the detection of fetal rhesus D antigen status, fetal sex, and common whole chromosomal aneuploidies is now well established, although testing for aneuploidy is still considered screening and not diagnostic. Further advances in technology and bioinformatics may see future clinical applications extend to the noninvasive detection of fetal subchromosomal aneuploidy, single gene disorders, and the entire fetal genome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ghinsberg, R; Meir, E; Blumstein, G; Kafeman, R
1975-11-01
The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.
How Memory Replay in Sleep Boosts Creative Problem-Solving.
Lewis, Penelope A; Knoblich, Günther; Poe, Gina
2018-06-01
Creative thought relies on the reorganisation of existing knowledge. Sleep is known to be important for creative thinking, but there is a debate about which sleep stage is most relevant, and why. We address this issue by proposing that rapid eye movement sleep, or 'REM', and non-REM sleep facilitate creativity in different ways. Memory replay mechanisms in non-REM can abstract rules from corpuses of learned information, while replay in REM may promote novel associations. We propose that the iterative interleaving of REM and non-REM across a night boosts the formation of complex knowledge frameworks, and allows these frameworks to be restructured, thus facilitating creative thought. We outline a hypothetical computational model which will allow explicit testing of these hypotheses. Copyright © 2018. Published by Elsevier Ltd.
Cost-effectiveness of rapid syphilis screening in prenatal HIV testing programs in Haiti.
Schackman, Bruce R; Neukermans, Christopher P; Fontain, Sandy N Nerette; Nolte, Claudine; Joseph, Patrice; Pape, Jean W; Fitzgerald, Daniel W
2007-05-01
New rapid syphilis tests permit simple and immediate diagnosis and treatment at a single clinic visit. We compared the cost-effectiveness, projected health outcomes, and annual cost of screening pregnant women using a rapid syphilis test as part of scaled-up prenatal testing to prevent mother-to-child HIV transmission in Haiti. A decision analytic model simulated health outcomes and costs separately for pregnant women in rural and urban areas. We compared syphilis syndromic surveillance (rural standard of care), rapid plasma reagin test with results and treatment at 1-wk follow-up (urban standard of care), and a new rapid test with immediate results and treatment. Test performance data were from a World Health Organization-Special Programme for Research and Training in Tropical Diseases field trial conducted at the GHESKIO Center Groupe Haitien d'Etude du Sarcome de Kaposi et des Infections Opportunistes in Port-au-Prince. Health outcomes were projected using historical data on prenatal syphilis treatment efficacy and included disability-adjusted life years (DALYs) of newborns, congenital syphilis cases, neonatal deaths, and stillbirths. Cost-effectiveness ratios are in US dollars/DALY from a societal perspective; annual costs are in US dollars from a payer perspective. Rapid testing with immediate treatment has a cost-effectiveness ratio of $6.83/DALY in rural settings and $9.95/DALY in urban settings. Results are sensitive to regional syphilis prevalence, rapid test sensitivity, and the return rate for follow-up visits. Integrating rapid syphilis testing into a scaled-up national HIV testing and prenatal care program would prevent 1,125 congenital syphilis cases and 1,223 stillbirths or neonatal deaths annually at a cost of $525,000. In Haiti, integrating a new rapid syphilis test into prenatal care and HIV testing would prevent congenital syphilis cases and stillbirths, and is cost-effective. A similar approach may be beneficial in other resource-poor countries that are scaling up prenatal HIV testing.
Two schemes for rapid generation of digital video holograms using PC cluster
NASA Astrophysics Data System (ADS)
Park, Hanhoon; Song, Joongseok; Kim, Changseob; Park, Jong-Il
2017-12-01
Computer-generated holography (CGH), which is a process of generating digital holograms, is computationally expensive. Recently, several methods/systems of parallelizing the process using graphic processing units (GPUs) have been proposed. Indeed, use of multiple GPUs or a personal computer (PC) cluster (each PC with GPUs) enabled great improvements in the process speed. However, extant literature has less often explored systems involving rapid generation of multiple digital holograms and specialized systems for rapid generation of a digital video hologram. This study proposes a system that uses a PC cluster and is able to more efficiently generate a video hologram. The proposed system is designed to simultaneously generate multiple frames and accelerate the generation by parallelizing the CGH computations across a number of frames, as opposed to separately generating each individual frame while parallelizing the CGH computations within each frame. The proposed system also enables the subprocesses for generating each frame to execute in parallel through multithreading. With these two schemes, the proposed system significantly reduced the data communication time for generating a digital hologram when compared with that of the state-of-the-art system.
Rapid hiv testing in urban outreach: a strategy for improving posttest counseling rates.
Keenan, P A; Keenan, J M
2001-12-01
In 1998, 48% of persons who had HIV testing at publicly funded sites in the United States failed to return for test results and posttest counseling. Opportunities for timely HIV therapy were lost; valuable resources were wasted. This study tested the hypothesis that rapid HIV testing enables a high percentage of high-risk outreach clients to learn their serostatus. We did on-site counseling and rapid HIV testing at community-based organizations (e.g., chemical dependency programs, homeless shelters) in North Minneapolis. The project tested 735 persons. All but one (99.9%) learned their HIV serostatus. African Americans made up 79% of subjects. Rapid testing has a role to play in HIV outreach. It is useful in populations who are at high risk of HIV infection, who currently are not accessing HIV testing, and who have high failure to return rates. Future developments in rapid testing technology will make this testing option more convenient and cost-effective.
Rapid automated superposition of shapes and macromolecular models using spherical harmonics.
Konarev, Petr V; Petoukhov, Maxim V; Svergun, Dmitri I
2016-06-01
A rapid algorithm to superimpose macromolecular models in Fourier space is proposed and implemented ( SUPALM ). The method uses a normalized integrated cross-term of the scattering amplitudes as a proximity measure between two three-dimensional objects. The reciprocal-space algorithm allows for direct matching of heterogeneous objects including high- and low-resolution models represented by atomic coordinates, beads or dummy residue chains as well as electron microscopy density maps and inhomogeneous multi-phase models ( e.g. of protein-nucleic acid complexes). Using spherical harmonics for the computation of the amplitudes, the method is up to an order of magnitude faster than the real-space algorithm implemented in SUPCOMB by Kozin & Svergun [ J. Appl. Cryst. (2001 ▸), 34 , 33-41]. The utility of the new method is demonstrated in a number of test cases and compared with the results of SUPCOMB . The spherical harmonics algorithm is best suited for low-resolution shape models, e.g . those provided by solution scattering experiments, but also facilitates a rapid cross-validation against structural models obtained by other methods.
Variable input observer for state estimation of high-rate dynamics
NASA Astrophysics Data System (ADS)
Hong, Jonathan; Cao, Liang; Laflamme, Simon; Dodson, Jacob
2017-04-01
High-rate systems operating in the 10 μs to 10 ms timescale are likely to experience damaging effects due to rapid environmental changes (e.g., turbulence, ballistic impact). Some of these systems could benefit from real-time state estimation to enable their full potential. Examples of such systems include blast mitigation strategies, automotive airbag technologies, and hypersonic vehicles. Particular challenges in high-rate state estimation include: 1) complex time varying nonlinearities of system (e.g. noise, uncertainty, and disturbance); 2) rapid environmental changes; 3) requirement of high convergence rate. Here, we propose using a Variable Input Observer (VIO) concept to vary the input space as the event unfolds. When systems experience high-rate dynamics, rapid changes in the system occur. To investigate the VIO's potential, a VIO-based neuro-observer is constructed and studied using experimental data collected from a laboratory impact test. Results demonstrate that the input space is unique to different impact conditions, and that adjusting the input space throughout the dynamic event produces better estimations than using a traditional fixed input space strategy.
A High-Throughput Enzyme Assay for Organophosphate Residues in Milk
Mishra, Rupesh K.; Deshpande, Kanchanmala; Bhand, Sunil
2010-01-01
A rapid, high-sensitivity, chemiluminescence (CL) enzyme assay for the determination of organophosphate (OP) residues in milk is presented. The assay for quantification of OP residues in milk is based on the inhibition of enzyme butyrylcholinesterase (BuChE). BuChE was stabilized and preloaded in 384 well plates at 30 °C. The assay permits rapid determination of OPs in milk within 12 min including an incubation step. The enzyme assay was tested for individual and mixtures of OPs such as methyl paraoxon (MPOx), methyl parathion (MP) and malathion (MT) in milk to evaluate their synergistic effect on BuChE inhibition. Good linearity was obtained in the range 0.005–50 μg·L−1 for MPOx and 0.5–1,000 μg·L−1 for MP as well as MT in milk. Mean recovery of 93.2%–98.6% was obtained for MPOx spiked milk samples with 0.99%–1.67% reproducibility (RSD). The proposed method facilitated rapid screening of milk samples in 384 well plate formats with further miniaturization presented in 1,536 well plates. PMID:22163525
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoke, Anderson; Shirazi, Mariko; Chakraborty, Sudipta
As deployment of power electronic coupled generation such as photovoltaic (PV) systems increases, grid operators have shown increasing interest in calling on inverter-coupled generation to help mitigate frequency contingency events by rapidly surging active power into the grid. When responding to contingency events, the faster the active power is provided, the more effective it may be for arresting the frequency event. This paper proposes a predictive PV inverter control method for very fast and accurate control of active power. This rapid active power control method will increase the effectiveness of various higher-level controls designed to mitigate grid frequency contingency events,more » including fast power-frequency droop, inertia emulation, and fast frequency response, without the need for energy storage. The rapid active power control method, coupled with a maximum power point estimation method, is implemented in a prototype PV inverter connected to a PV array. The prototype inverter's response to various frequency events is experimentally confirmed to be fast (beginning within 2 line cycles and completing within 4.5 line cycles of a severe test event) and accurate (below 2% steady-state error).« less
Bacteria-powered battery on paper.
Fraiwan, Arwa; Choi, Seokheun
2014-12-21
Paper-based devices have recently emerged as simple and low-cost paradigms for fluid manipulation and analytical/clinical testing. However, there are significant challenges in developing paper-based devices at the system level, which contain integrated paper-based power sources. Here, we report a microfabricated paper-based bacteria-powered battery that is capable of generating power from microbial metabolism. The battery on paper showed a very short start-up time relative to conventional microbial fuel cells (MFCs); paper substrates eliminated the time traditional MFCs required to accumulate and acclimate bacteria on the anode. Only four batteries connected in series provided desired values of current and potential to power an LED for more than 30 minutes. The battery featured (i) a low-cost paper-based proton exchange membrane directly patterned on commercially available parchment paper and (ii) paper reservoirs for holding the anolyte and the catholyte for an extended period of time. Based on this concept, we also demonstrate the use of paper-based test platforms for the rapid characterization of electricity-generating bacteria. This paper-based microbial screening tool does not require external pumps/tubings and represents the most rapid test platform (<50 min) compared with the time needed by using traditional screening tools (up to 103 days) and even recently proposed MEMS arrays (< 2 days).
Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan
2017-06-06
Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable.
Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan
2017-01-01
Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable. PMID:28587275
Frimpong, Jemima A; D'Aunno, Thomas; Perlman, David C; Strauss, Shiela M; Mallow, Alissa; Hernandez, Diana; Schackman, Bruce R; Feaster, Daniel J; Metsch, Lisa R
2016-03-03
More than 1.2 million people in the United States are living with human immunodeficiency virus (HIV), and 3.2 million are living with hepatitis C virus (HCV). An estimated 25 % of persons living with HIV also have HCV. It is therefore of great public health importance to ensure the prompt diagnosis of both HIV and HCV in populations that have the highest prevalence of both infections, including individuals with substance use disorders (SUD). In this theory-driven, efficacy-effectiveness-implementation hybrid study, we will develop and test an on-site bundled rapid HIV/HCV testing intervention for SUD treatment programs. Its aim is to increase the receipt of HIV and HCV test results among SUD treatment patients. Using a rigorous process involving patients, providers, and program managers, we will incorporate rapid HCV testing into evidence-based HIV testing and linkage to care interventions. We will then test, in a randomized controlled trial, the extent to which this bundled rapid HIV/HCV testing approach increases receipt of HIV and HCV test results. Lastly, we will conduct formative research to understand the barriers to, and facilitators of, the adoption, implementation, and sustainability of the bundled rapid testing strategy in SUD treatment programs. Novel approaches that effectively integrate on-site rapid HIV and rapid HCV testing are needed to address both the HIV and HCV epidemics. If feasible and efficacious, bundled rapid HIV/HCV testing may offer a scalable, potentially cost-effective approach to testing high-risk populations, such as patients of SUD treatment programs. It may ultimately lead to improved linkage to care and progress through the HIV and HCV care and treatment cascades. ClinicalTrials.gov: NCT02355080 . (30 January 2015).
[Benefits of using rapid HIV testing at the PMU-FLON walk-in clinic in Lausanne].
Gilgien, W; Aubert, J; Bischoff, T; Herzig, L; Perdrix, J
2012-05-16
Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.
Demographic stability metrics for conservation prioritization of isolated populations.
Finn, Debra S; Bogan, Michael T; Lytle, David A
2009-10-01
Systems of geographically isolated habitat patches house species that occur naturally as small, disjunct populations. Many of these species are of conservation concern, particularly under the interacting influences of isolation and rapid global change. One potential conservation strategy is to prioritize the populations most likely to persist through change and act as sources for future recolonization of less stable localities. We propose an approach to classify long-term population stability (and, presumably, future persistence potential) with composite demographic metrics derived from standard population-genetic data. Stability metrics can be related to simple habitat measures for a straightforward method of classifying localities to inform conservation management. We tested these ideas in a system of isolated desert headwater streams with mitochondrial sequence data from 16 populations of a flightless aquatic insect. Populations exhibited a wide range of stability scores, which were significantly predicted by dry-season aquatic habitat size. This preliminary test suggests strong potential for our proposed method of classifying isolated populations according to persistence potential. The approach is complementary to existing methods for prioritizing local habitats according to diversity patterns and should be tested further in other systems and with additional loci to inform composite demographic stability scores.
Hybrid Network Defense Model Based on Fuzzy Evaluation
2014-01-01
With sustained and rapid developments in the field of information technology, the issue of network security has become increasingly prominent. The theme of this study is network data security, with the test subject being a classified and sensitive network laboratory that belongs to the academic network. The analysis is based on the deficiencies and potential risks of the network's existing defense technology, characteristics of cyber attacks, and network security technologies. Subsequently, a distributed network security architecture using the technology of an intrusion prevention system is designed and implemented. In this paper, first, the overall design approach is presented. This design is used as the basis to establish a network defense model, an improvement over the traditional single-technology model that addresses the latter's inadequacies. Next, a distributed network security architecture is implemented, comprising a hybrid firewall, intrusion detection, virtual honeynet projects, and connectivity and interactivity between these three components. Finally, the proposed security system is tested. A statistical analysis of the test results verifies the feasibility and reliability of the proposed architecture. The findings of this study will potentially provide new ideas and stimuli for future designs of network security architecture. PMID:24574870
NASA Astrophysics Data System (ADS)
Prastowo, T.; Madlazim
2018-01-01
This preliminary study aims to propose a new method of real-time detection and characterization of nuclear explosions by analyzing broadband seismic waveforms acquired from a network of regional seismic stations. Signal identification generated by a nuclear test was differentiated from natural sources of either earthquakes or other natural seismo-tectonic events by verifying crucial parameters, namely source depth, type of first motion, and P-wave domination of the broadband seismic wavesunder consideration. We examined and analyzed a recently hypothetical nuclear test performed by the North Koreangovernment that occurred on September 3, 2017 as a vital point to study. From spectral analyses, we found that the source of corresponding signals associated with detonations of the latest underground nuclear test was at a much shallower depth below the surface relatively compared with that of natural earthquakes, the suspected nuclear explosions produced compressional waves with radially directed outward from the source for their first motions, and the waves were only dominated by P-components. The results are then discussed in the context of potential uses of the proposed methodology for human-induced disaster early warning system and/or the need of rapid response purposes for minimizing the disaster risks.
Zhang, Hong-Guang; Yang, Qin-Min; Lu, Jian-Gang
2014-04-01
In this paper, a novel discriminant methodology based on near infrared spectroscopic analysis technique and least square support vector machine was proposed for rapid and nondestructive discrimination of different types of Polyacrylamide. The diffuse reflectance spectra of samples of Non-ionic Polyacrylamide, Anionic Polyacrylamide and Cationic Polyacrylamide were measured. Then principal component analysis method was applied to reduce the dimension of the spectral data and extract of the principal compnents. The first three principal components were used for cluster analysis of the three different types of Polyacrylamide. Then those principal components were also used as inputs of least square support vector machine model. The optimization of the parameters and the number of principal components used as inputs of least square support vector machine model was performed through cross validation based on grid search. 60 samples of each type of Polyacrylamide were collected. Thus a total of 180 samples were obtained. 135 samples, 45 samples for each type of Polyacrylamide, were randomly split into a training set to build calibration model and the rest 45 samples were used as test set to evaluate the performance of the developed model. In addition, 5 Cationic Polyacrylamide samples and 5 Anionic Polyacrylamide samples adulterated with different proportion of Non-ionic Polyacrylamide were also prepared to show the feasibilty of the proposed method to discriminate the adulterated Polyacrylamide samples. The prediction error threshold for each type of Polyacrylamide was determined by F statistical significance test method based on the prediction error of the training set of corresponding type of Polyacrylamide in cross validation. The discrimination accuracy of the built model was 100% for prediction of the test set. The prediction of the model for the 10 mixing samples was also presented, and all mixing samples were accurately discriminated as adulterated samples. The overall results demonstrate that the discrimination method proposed in the present paper can rapidly and nondestructively discriminate the different types of Polyacrylamide and the adulterated Polyacrylamide samples, and offered a new approach to discriminate the types of Polyacrylamide.
Stevinson, Kendall; Martin, Eugene G; Marcella, Stephen; Paul, Sindy M
2011-12-01
Before 2009, New Jersey (NJ) publicly funded counseling and testing sites (CTS) tested for HIV using a single rapid test followed, when positive, by a Western Blot (WB) for confirmation. With this strategy, 74.8% of confirmed positive clients returned to receive test results. To improve the client notification rate at these centers, the New Jersey (NJ) Division of HIV, STD and TB Services (DHSTS) implemented a rapid testing algorithm (RTA) which utilizes a second, different, rapid test to verify a preliminary positive. To compare the cost-effectiveness of the two testing algorithms. This was a retrospective cost-effectiveness analysis. New Jersey HIV Rapid Testing Support Program (NJHIV) records, DHSTS grant documents, counseling time estimates from an online survey of site supervisors. Costs included test kits and personnel costs from month of RTA implementation through 11/30 in 2008 and 2009. The incremental cost of the RTA was calculated per additional percent of positive clients who were notified and per day earlier notification. In 2008, 215 of 247 clients with a positive rapid HIV test were confirmed positive by WB. 90.9% of clients were notified a mean of 11.4 days after their initial test. 12 refused confirmatory WB. In 2009, 152 of 170 clients with one positive rapid test had a confirmatory second positive rapid test and were notified on the same day. The incremental cost of the RTA was $20.31 per additional positive person notified and $24.31 per day earlier notification or $3.23 per additional positive person and $3.87 per day earlier notification if the WB were eliminated. The RTA is a cost-effective strategy achieving 100% notification of newly HIV positive clients a mean of 11.4 days earlier compared to standard testing. Copyright © 2011 Elsevier B.V. All rights reserved.
Degradation mechanisms and accelerated testing in PEM fuel cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borup, Rodney L; Mukundan, Rangachary
2010-01-01
The durability of PEM fuel cells is a major barrier to the commercialization of these systems for stationary and transportation power applications. Although there has been recent progress in improving durability, further improvements are needed to meet the commercialization targets. Past improvements have largely been made possible because of the fundamental understanding of the underlying degradation mechanisms. By investigating component and cell degradation modes; defining the fundamental degradation mechanisms of components and component interactions new materials can be designed to improve durability. Various factors have been shown to affect the useful life of PEM fuel cells. Other issues arise frommore » component optimization. Operational conditions (such as impurities in either the fuel and oxidant stream), cell environment, temperature (including subfreezing exposure), pressure, current, voltage, etc.; or transient versus continuous operation, including start-up and shutdown procedures, represent other factors that can affect cell performance and durability. The need for Accelerated Stress Tests (ASTs) can be quickly understood given the target lives for fuel cell systems: 5000 hours ({approx} 7 months) for automotive, and 40,000 hrs ({approx} 4.6 years) for stationary systems. Thus testing methods that enable more rapid screening of individual components to determine their durability characteristics, such as off-line environmental testing, are needed for evaluating new component durability in a reasonable turn-around time. This allows proposed improvements in a component to be evaluated rapidly and independently, subsequently allowing rapid advancement in PEM fuel cell durability. These tests are also crucial to developers in order to make sure that they do not sacrifice durability while making improvements in costs (e.g. lower platinum group metal [PGM] loading) and performance (e.g. thinner membrane or a GDL with better water management properties). To achieve a deeper understanding and improve PEM fuel cell durability LANL is conducting research to better define fuel cell component degradation mechanisms and correlate AST measurements to component in 'real-world' situations.« less
Comparison of Multispot EIA with Western blot for confirmatory serodiagnosis of HIV.
Torian, Lucia V; Forgione, Lisa A; Punsalang, Amado E; Pirillo, Robert E; Oleszko, William R
2011-12-01
Recent improvements in the sensitivity of immunoassays (IA) used for HIV screening, coupled with increasing recognition of the importance of rapid point-of-care testing, have led to proposals to adjust the algorithm for serodiagnosis of HIV so that screening and confirmation can be performed using a dual or triple IA sequence that does not require Western blotting for confirmation. One IA that has been proposed as a second or confirmatory test is the Bio-Rad Multispot(®) Rapid HIV-1/HIV-2 Test. This test would have the added advantage of differentiating between HIV-1 and HIV-2 antibodies. To compare the sensitivity and type-specificity of an algorithm combining a 3rd generation enzyme immunoassay (EIA) followed by a confirmatory Multispot with the conventional algorithm that combines a 3rd generation EIA (Bio-Rad GS HIV-1/HIV-2 Plus O EIA) followed by confirmatory Western blot (Bio-Rad GS HIV-1 WB). 8760 serum specimens submitted for HIV testing to the New York City Public Health Laboratory between May 22, 2007, and April 30, 2010, tested repeatedly positive on 3rd generation HIV-1-2+O EIA screening and received parallel confirmatory testing by WB and Multispot (MS). 8678/8760 (99.1%) specimens tested WB-positive; 82 (0.9%) tested WB-negative or indeterminate (IND). 8690/8760 specimens (99.2%) tested MS-positive, of which 14 (17.1%) had been classified as negative or IND by WB. Among the HIV-1 WB-positive specimens, MS classified 26 (0.29%) as HIV-2. Among the HIV-1 WB negative and IND, MS detected 12 HIV-2. MS detected an additional 14 HIV-1 infections among WB negative or IND specimens, differentiated 26 HIV-1 WB positives as HIV-2, and detected 12 additional HIV-2 infections among WB negative/IND. A dual 3rd generation EIA algorithm incorporating MS had equivalent HIV-1 sensitivity to the 3rd generation EIA-WB algorithm and had the added advantage of detecting 12 HIV-2 specimens that were not HIV-1 WB cross-reactors. In this series an algorithm using EIA followed by MS would have resulted in the expedited referral of 38 specimens for HIV-2 testing and 40 specimens for nucleic acid confirmation. Further testing using a combined gold standard of nucleic acid detection and WB is needed to calculate specificity and validate the substitution of MS for WB in the diagnostic algorithm used by a large public health laboratory. Copyright © 2011. Published by Elsevier B.V.
An Anisotropic Hardening Model for Springback Prediction
NASA Astrophysics Data System (ADS)
Zeng, Danielle; Xia, Z. Cedric
2005-08-01
As more Advanced High-Strength Steels (AHSS) are heavily used for automotive body structures and closures panels, accurate springback prediction for these components becomes more challenging because of their rapid hardening characteristics and ability to sustain even higher stresses. In this paper, a modified Mroz hardening model is proposed to capture realistic Bauschinger effect at reverse loading, such as when material passes through die radii or drawbead during sheet metal forming process. This model accounts for material anisotropic yield surface and nonlinear isotropic/kinematic hardening behavior. Material tension/compression test data are used to accurately represent Bauschinger effect. The effectiveness of the model is demonstrated by comparison of numerical and experimental springback results for a DP600 straight U-channel test.
NASA Astrophysics Data System (ADS)
Xiong, H.; Hamila, N.; Boisse, P.
2017-10-01
Pre-impregnated thermoplastic composites have recently attached increasing interest in the automotive industry for their excellent mechanical properties and their rapid cycle manufacturing process, modelling and numerical simulations of forming processes for composites parts with complex geometry is necessary to predict and optimize manufacturing practices, especially for the consolidation effects. A viscoelastic relaxation model is proposed to characterize the consolidation behavior of thermoplastic prepregs based on compaction tests with a range of temperatures. The intimate contact model is employed to predict the evolution of the consolidation which permits the microstructure prediction of void presented through the prepreg. Within a hyperelastic framework, several simulation tests are launched by combining a new developed solid shell finite element and the consolidation models.
Evaluation of proposed Skylab and SSP soap products
NASA Technical Reports Server (NTRS)
Whitmore, F. C.; Durfee, R. L.; Spurlock, J. M.
1973-01-01
Three personal hygiene cleansing agents and one laundry detergent (sodium dodecyl benzene sulfonate), which are all candidates for use on long-duration space missions, were evaluated in terms of dermatological effects on human subjects and effects on microbiological species. None of the four materials exhibited adverse dermatological effects from either skin patch tests of two weeks duration or a simulated Skylab personal hygiene regimen of up to four weeks duration. No significant alterations in skin microflora during the use regimen were found. None of the four materials were found to serve as microbiological support media for the species tested, but a species of air-borne mold was observed to grow rapidly in a neutralized aqueous solution. None of the candidate agents was found to be strongly biocidal.
Hybrid nanosensor for colorimetric and ultrasensitive detection of nuclease contaminations
NASA Astrophysics Data System (ADS)
Cecere, Paola; Valentini, Paola; Pompa, Pier Paolo
2016-04-01
Nucleases are ubiquitous enzymes that degrade DNA or RNA, thus they can prejudice the good outcome of molecular biology experiments involving nucleic acids. We propose a colorimetric test for the naked-eye detection of nuclease contaminations. The system uses an hybrid nanosensor, based on gold nanoparticles functionalized with DNA probes. Our assay is rapid, instrument-free, simple and low-cost. Moreover, it reaches sensitivity equal or better than those of commercial kits, and presents a lot of advantageous aspects. Therefore, it is very competitive, with a real market potential. This test will be relevant in routine process monitoring in scientific laboratories, and in quality control in clinical laboratories and industrial processes, allowing the simultaneous detection of nucleases with different substrate specificities and large-scale screening.
Hashemian, Amir Masoud; Ahmadi, Koorosh; Zamani Moghaddam, Hamid; Zakeri, Hosein; Davoodi Navakh, Seyed Akbar; Sharifi, Mohammad Davood; Bahrami, Abdollah
2015-10-01
Spontaneous bacterial peritonitis (SBP) is a common and important clinical problem and is life-threatening in decompensated liver disease. Ascites fluid test by leukocyte esterase test strip has been recently proposed as an effective and rapid method to diagnose SBP in patients with cirrhosis. This study aimed to evaluate sensitivity and specificity of leukocyte esterase test strip in the diagnosis of SBP. The population of this research was all patients with cirrhosis and ascites admitted to the emergency room at Imam Reza (AS) hospital, Mashhad. A written consent was taken for inclusion in the study. 50 mL ascites sample was taken from all patients for use in a urine test strip (LER) (Urine Test Strips Convergys®Urine Matrix 11). The patient's ascites samples were evaluated for cell counting. Positive dipstick test for LER in this study considered as grade 3 +. The values of WBC > 500 cell/mm(3) or PMN > 250 cell/mm(3) considered as positive result of the gold standard method for the diagnosis of SBP. In this study, 100 patients with ascites due to cirrhosis, with an average age of 38.9 ± 6.54 years were evaluated. Twenty cases had positive results, of whom 17 cases were also detected based on the standard diagnostic criteria and other three cases were healthy individuals. Thus, sensitivity, specificity, positive and negative predictive values, and accuracy of the method were 95%, 96.3%, 85%, 97.5% and 95%, respectively. The use of leukocyte esterase urine dipstick test can be a quick and easy method in early diagnosis of SBP to start the treatment until preparation of SBP-cell count results.
Engler, Kim; Rollet, Kathleen; Lessard, David; Thomas, Réjean; Lebouché, Bertrand
2016-10-01
Quebec's HIV epidemic persists, particularly among men who have sex with men (MSM) and in Montreal. Increasing access to HIV testing is necessary and community-based rapid testing offers one strategy. This paper examines the clienteles and activities of a rapid HIV testing site in Montreal, the pilot project Actuel sur Rue. Comparative analyses were conducted with 1357 MSM, 147 heterosexual men and 64 women who visited Actuel sur Rue between July 2012 and November 2013 on socio-demographics, health, drug use, sexual practices/infection and HIV testing/prevention. Significant group differences were observed in each category. Actuel sur Rue received 1901 clients, conducted 1417 rapid HIV tests and tested 77 never-tested individuals. Rapid testing produced a high reactive rate (2%). Only 1/28 of those with reactive tests had no previous HIV testing, and 36% had used post-exposure prophylaxis, suggesting missed opportunities for prevention. Findings highlight diverse client vulnerability profiles and the relevance of checkpoints and further prevention efforts. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Kalin, B.; Penyaz, M.; Ivannikov, A.; Sevryukov, O.; Bachurina, D.; Fedotov, I.; Voennov, A.; Abramov, E.
2018-01-01
Recently, the use rapidly quenched boron-containing nickel filler metals for high temperature brazing corrosion resistance steels different classes is perspective. The use of these alloys leads to the formation of a complex heterogeneous structure in the diffusion zone that contains separations of intermediate phases such as silicides and borides. This structure negatively affects the strength characteristics of the joint, especially under dynamic loads and in corrosive environment. The use of non-boron filler metals based on the Ni-Si-Be system is proposed to eliminate this structure in the brazed seam. Widely used austenitic 12Cr18Ni10Ti and ferrite-martensitic 16Cr12MoSiWNiVNb reactor steels were selected for research and brazing was carried out. The mechanical characteristics of brazed joints were determined using uniaxial tensile and impact toughness tests, and fractography was investigated by electron microscopy.
Implicit and Explicit Contributions to Object Recognition: Evidence from Rapid Perceptual Learning
Hassler, Uwe; Friese, Uwe; Gruber, Thomas
2012-01-01
The present study investigated implicit and explicit recognition processes of rapidly perceptually learned objects by means of steady-state visual evoked potentials (SSVEP). Participants were initially exposed to object pictures within an incidental learning task (living/non-living categorization). Subsequently, degraded versions of some of these learned pictures were presented together with degraded versions of unlearned pictures and participants had to judge, whether they recognized an object or not. During this test phase, stimuli were presented at 15 Hz eliciting an SSVEP at the same frequency. Source localizations of SSVEP effects revealed for implicit and explicit processes overlapping activations in orbito-frontal and temporal regions. Correlates of explicit object recognition were additionally found in the superior parietal lobe. These findings are discussed to reflect facilitation of object-specific processing areas within the temporal lobe by an orbito-frontal top-down signal as proposed by bi-directional accounts of object recognition. PMID:23056558
Reynolds-stress and dissipation-rate budgets in a turbulent channel flow
NASA Technical Reports Server (NTRS)
Mansour, N. N.; Kim, J.; Moin, P.
1988-01-01
The budgets for the Reynolds stresses and for the dissipation rate of the turbulence kinetic energy are computed using direct simulation data of a turbulent channel flow. The budget data reveal that all the terms in the budget become important close to the wall. For inhomogeneous pressure boundary conditions, the pressure-strain term is split into a return term, a rapid term, and a Stokes term. The Stokes term is important close to the wall. The rapid and return terms play different roles depending on the component of the term. A split of the velocity pressure-gradient term into a redistributive term and a diffusion term is proposed, which should be simpler to model. The budget data is used to test existing closure models for the pressure-strain term, the dissipation rate, and the transport rate. In general, further work is needed to improve the models.
Reynolds-stress and dissipation rate budgets in a turbulent channel flow
NASA Technical Reports Server (NTRS)
Mansour, N. N.; Kim, J.; Moin, P.
1987-01-01
The budgets for the Reynolds stresses and for the dissipation rate of the turbulence kinetic energy are computed using direct simulation data of a turbulent channel flow. The budget data reveal that all the terms in the budget become important close to the wall. For inhomogeneous pressure boundary conditions, the pressure-strain term is split into a return term, a rapid term, and a Stokes term. The Stokes term is important close to the wall. The rapid and return terms play different roles depending on the component of the term. A split of the velocity pressure-gradient term into a redistributive term and a diffusion term is proposed, which should be simpler to model. The budget data is used to test existing closure models for the pressure-strain term, the dissipation rate, and the transport rate. In general, further work is needed to improve the models.
Biconically tapered fiber optic probes for rapid label-free immunoassays.
Miller, John; Castaneda, Angelica; Lee, Kun Ho; Sanchez, Martin; Ortiz, Adrian; Almaz, Ekrem; Almaz, Zuleyha Turkoglu; Murinda, Shelton; Lin, Wei-Jen; Salik, Ertan
2015-04-01
We report use of U-shaped biconically tapered optical fibers (BTOF) as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G) and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G)-antigen (rabbit anti-mouse IgG) reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.
The Rapid Integration and Test Environment: A Process for Achieving Software Test Acceptance
2010-05-01
Test Environment : A Process for Achieving Software Test Acceptance 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...mlif`v= 365= k^s^i=mlpqdo^ar^qb=p`elli= The Rapid Integration and Test Environment : A Process for Achieving Software Test Acceptance Patrick V...was awarded the Bronze Star. Introduction The Rapid Integration and Test Environment (RITE) initiative, implemented by the Program Executive Office
NASA Astrophysics Data System (ADS)
Fairley, J. P., Jr.; Oyarzún L, R.; Villegas, G.
2015-12-01
Early theories of fluid migration in unsaturated fractured rock hypothesized that matrix suction would dominate flow up to the point of matrix saturation. However, experiments in underground laboratories such as the ESF (Yucca Mountain, NV) have demonstrated that liquid water can migrate significant distances through fractures in an unsaturated porous medium, suggesting limited interaction between fractures and unsaturated matrix blocks and potentially rapid transmission of recharge to the sat- urated zone. Determining the conditions under which this rapid recharge may take place is an important factor in understanding deep percolation processes in arid areas with thick unsaturated zones. As part of an on-going, Fondecyt-funded project (award 11150587) to study mountain block hydrological processes in arid regions, we are plan- ning a series of in-situ fracture flow injection tests in the Cerro Brillador/Mina Escuela, an underground laboratory and teaching facility belonging to the Universidad la Serena, Chile. Planning for the tests is based on an analytical model and curve-matching method, originally developed to evaluate data from injection tests at Yucca Mountain (Fairley, J.P., 2010, WRR 46:W08542), that uses a known rate of liquid injection to a fracture (for example, from a packed-off section of borehole) and the observed rate of seepage discharging from the fracture to estimate effective fracture aperture, matrix sorptivity, fracture/matrix flow partitioning, and the wetted fracture/matrix interac- tion area between the injection and recovery points. We briefly review the analytical approach and its application to test planning and analysis, and describe the proposed tests and their goals.
NASA Astrophysics Data System (ADS)
Kodama, Kazuto
2015-02-01
This study proposes a new method for measuring transient magnetization of natural samples induced by a pulsed field with duration of 11 ms using a pulse magnetizer. An experimental system was constructed, consisting of a pair of differential sensing coils connected with a high-speed digital oscilloscope for data acquisition. The data were transferred to a computer to obtain an initial magnetization curve and a descending branch of a hysteresis loop in a rapidly changing positive field. This system was tested with synthetic samples (permalloy ribbon, aluminum plate, and nickel powder) as well as two volcanic rock samples. Results from the synthetic samples showed considerable differences from those measured by a quasi-static method using a vibrating sample magnetometer (VSM). These differences were principally due to the time-dependent magnetic properties or to electromagnetic effects, such as magnetic viscosity, eddy current loss, or magnetic relaxation. Results from the natural samples showed that the transient magnetization-field curves were largely comparable to the corresponding portions of the hysteresis loops. However, the relative magnetization (scaled to the saturation magnetization) at the end of a pulse was greater than that measured by a VSM. This discrepancy, together with the occurrence of rapid exponential decay after a pulse, indicates magnetic relaxations that could be interpreted in terms of domain wall displacement. These results suggest that with further developments, the proposed technique can become a useful tool for characterizing magnetic particles contained in a variety of natural materials.
Wang, Ting; Li, Weiying; Zheng, Xiaofeng; Lin, Zhifen; Kong, Deyang
2014-02-01
During the last past decades, there is an increasing number of studies about estrogenic activities of the environmental pollutants on amphibians and many determination methods have been proposed. However, these determination methods are time-consuming and expensive, and a rapid and simple method to screen and test the chemicals for estrogenic activities to amphibians is therefore imperative. Herein is proposed a new decision tree formulated not only with physicochemical parameters but also a biological parameter that was successfully used to screen estrogenic activities of the chemicals on amphibians. The biological parameter, CDOCKER interaction energy (Ebinding ) between chemicals and the target proteins was calculated based on the method of molecular docking, and it was used to revise the decision tree formulated by Hong only with physicochemical parameters for screening estrogenic activity of chemicals in rat. According to the correlation between Ebinding of rat and Xenopus laevis, a new decision tree for estrogenic activities in Xenopus laevis is finally proposed. Then it was validated by using the randomly 8 chemicals which can be frequently exposed to Xenopus laevis, and the agreement between the results from the new decision tree and the ones from experiments is generally satisfactory. Consequently, the new decision tree can be used to screen the estrogenic activities of the chemicals, and combinational use of the Ebinding and classical physicochemical parameters can greatly improves Hong's decision tree. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Protein Chips for Detection of Salmonella spp. from Enrichment Culture
Poltronieri, Palmiro; Cimaglia, Fabio; De Lorenzis, Enrico; Chiesa, Maurizio; Mezzolla, Valeria; Reca, Ida Barbara
2016-01-01
Food pathogens are the cause of foodborne epidemics, therefore there is a need to detect the pathogens in food productions rapidly. A pre-enrichment culture followed by selective agar plating are standard detection methods. Molecular methods such as qPCR have provided a first rapid protocol for detection of pathogens within 24 h of enrichment culture. Biosensors also may provide a rapid tool to individuate a source of Salmonella contamination at early times of pre-enrichment culture. Forty mL of Salmonella spp. enrichment culture were processed by immunoseparation using the Pathatrix, as in AFNOR validated qPCR protocols. The Salmonella biosensor combined with immunoseparation showed a limit of detection of 100 bacteria/40 mL, with a 400 fold increase to previous results. qPCR analysis requires processing of bead-bound bacteria with lysis buffer and DNA clean up, with a limit of detection of 2 cfu/50 μL. Finally, a protein chip was developed and tested in screening and identification of 5 common pathogen species, Salmonella spp., E. coli, S. aureus, Campylobacter spp. and Listeria spp. The protein chip, with high specificity in species identification, is proposed to be integrated into a Lab-on-Chip system, for rapid and reproducible screening of Salmonella spp. and other pathogen species contaminating food productions. PMID:27110786
Parra, R; Ulery, A L; Elless, M P; Blaylock, M J
2008-01-01
The phytoremediation of recalcitrant metals such as lead and uranium rely on soil amendments to enhance metal availability within the rhizosphere. Because these amendments may persist in soils, agents that not only biodegrade rapidly but also are effective in triggering metal uptake in plants are needed for metals phytoextraction to be considered as an accepted practice. In this study, several biodegradable organic acids and chelating agents were assessed to determine if these amendments can be used in an effective manner, and if their activity and use is consistent with a proposed class of soil amendments for phytoextraction, here termed transient phytoextraction agents (TPAs). A TPA is proposed as an agent that would exhibit both effectiveness in triggering plant accumulation of the targeted metal while minimizing the risk of migration through rapid degradation or inactivation of the soluble complex. Eleven candidate TPAs (acetic acid, ascorbic acid, citric acid, malic acid, oxalic acid, succinic acid, ethylenediaminedisuccinic acid, dicarboxymethylglutamic acid, nitrilotriacetic acid, BayPure CX 100, and the siderophore desferrioxamine B) were tested in batch studies to evaluate their complexation behavior using contaminated soils, with uranium and lead as the target metals. A growth chamber study was then conducted with Brassica juncea (Indian mustard), Helianthus annuus (sunflower), and Festuca arundinacea (tall fescue) grown in a lead-contaminated soil that was treated with the candidate TPAs to assess phytoextraction effectiveness. For the soils tested, citric acid, oxalic acid, and succinic acid were found to be effective complexing agents for uranium phytoextraction, whereas Baypure CX 100 and citric acid exhibited effectiveness for lead phytoextraction.
Rapid diagnostic tests for malaria
Daily, Jennifer; Hotte, Nora; Dolkart, Caitlin; Cunningham, Jane; Yadav, Prashant
2015-01-01
Abstract Maintaining quality, competitiveness and innovation in global health technology is a constant challenge for manufacturers, while affordability, access and equity are challenges for governments and international agencies. In this paper we discuss these issues with reference to rapid diagnostic tests for malaria. Strategies to control and eliminate malaria depend on early and accurate diagnosis. Rapid diagnostic tests for malaria require little training and equipment and can be performed by non-specialists in remote settings. Use of these tests has expanded significantly over the last few years, following recommendations to test all suspected malaria cases before treatment and the implementation of an evaluation programme to assess the performance of the malaria rapid diagnostic tests. Despite these gains, challenges exist that, if not addressed, could jeopardize the progress made to date. We discuss recent developments in rapid diagnostic tests for malaria, highlight some of the challenges and provide suggestions to address them. PMID:26668438
[Concordance among invasive diagnostic procedures for Helicobacter pylori infection in adults].
Sánchez-Cuén, Jaime Alberto; Canizalez-Román, Vicente Adrián; León-Sicairos, Nidia Maribel; Irineo-Cabrales, Ana Bertha; Bernal-Magaña, Gregorio
2015-01-01
Compare the strength of concordance between culture, histology, rapid urease test for diagnosis of Helicobacter pylori infection and histopathological findings relationship and frequency of positivity among such diagnostic procedures. Diagnostic test study. The study population were subjects with endoscopy and take samples of gastric antral. Rapid urease test (one sample), histology (two samples) and culture (two samples), and histopathological findings of gastric mucosa were performed. Statistical design with Student's t, Fisher exact test, Kappa coefficient. We reviewed 108 subjects, 28 (25.9%) men, 80 (74.1%) women, mean age was 49.1 years (SD 15.1). The Kappa coefficient was 0.729 and 0.377 between culture with histology and rapid urease test, respectively; likewise the Kappa coefficient was 0.565 between histology and rapid urease test. The strength of concordance was higher between histology with culture and rapid urease test; the most recommended being histology in clinical practice for the detection of Helicobacter pylori infection.
9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false The stained-antigen, rapid, whole-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure...
9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false The stained-antigen, rapid, whole-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure...
9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false The stained-antigen, rapid, whole-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure...
9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false The stained-antigen, rapid, whole-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure...
9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false The stained-antigen, rapid, whole-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure...
Raskin, Cody; Owen, J. Michael
2016-10-24
Here, we discuss a generalization of the classic Keplerian disk test problem allowing for both pressure and rotational support, as a method of testing astrophysical codes incorporating both gravitation and hydrodynamics. We argue for the inclusion of pressure in rotating disk simulations on the grounds that realistic, astrophysical disks exhibit non-negligible pressure support. We then apply this test problem to examine the performance of various smoothed particle hydrodynamics (SPH) methods incorporating a number of improvements proposed over the years to address problems noted in modeling the classical gravitation-only Keplerian disk. We also apply this test to a newly developed extensionmore » of SPH based on reproducing kernels called CRKSPH. Counterintuitively, we find that pressure support worsens the performance of traditional SPH on this problem, causing unphysical collapse away from the steady-state disk solution even more rapidly than the purely gravitational problem, whereas CRKSPH greatly reduces this error.« less
Rapid plasma reagin test; Syphilis screening test ... Chernecky CC, Berger BJ. Rapid plasma regain (RPR) test – blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier ...
76 FR 76736 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-08
... Project Survey of Rapid Influenza Diagnostic Test (RIDT) Practices in Laboratories-NEW--the Office of...). Background and Brief Description The Survey of Rapid Influenza Diagnostic Testing Practices in Laboratories is a national systematic study investigating rapid influenza diagnostic testing practices in clinical...
Liu, H; Cai, L P; Xue, H; Zhao, Y; Wu, D; Zhang, D P; Yin, W Y; Sun, J P
2016-10-06
Currently, a growing number of community-based organizations are providing rapid HIV testing service in various forms, some people with specific needs also purchase HIV rapid test papers through online sales channels, those imply that the demand of HIV self-test is in increasing year by year.In this paper, aims to understand the current situation of HIV rapid test led by CBOs and the approach, strategies and results of social marketing by means of expert interviews and site visits. Hope to illustrate the current situation, and make recommendations for future work.
Abubakar, I; Irvine, L; Aldus, C F; Wyatt, G M; Fordham, R; Schelenz, S; Shepstone, L; Howe, A; Peck, M; Hunter, P R
2007-09-01
To determine the diagnostic accuracy of tests for the rapid diagnosis of bacterial food poisoning in clinical and public health practice and to estimate the cost-effectiveness of these assays in a hypothetical population in order to inform policy on the use of these tests. Studies evaluating diagnostic accuracy of rapid tests were retrieved using electronic databases and handsearching reference lists and key journals. Hospital laboratories and test manufacturers were contacted for cost data, and clinicians involved in the care of patients with food poisoning were invited to discuss the conclusions of this review using the nominal group technique. A systematic review of the current medical literature on assays used for the rapid diagnosis of bacterial food poisoning was carried out. Specific organisms under review were Salmonella, Campylobacter, Escherichia coli O157, Staphylococcus aureus, Clostridium perfringens and Bacillus cereus. Data extraction was undertaken using standardised data extraction forms. Where a sufficient number of studies evaluating comparable tests were identified, meta-analysis was performed. A decision analytic model was developed, using effectiveness data from the review and cost data from hospitals and manufacturers, which contributed to an assessment of the cost-effectiveness of rapid tests in a hypothetical UK population. Finally, diagnostic accuracy and cost-effectiveness results were presented to a focus group of GPs, microbiologists and consultants in communicable disease control, to assess professional opinion on the use of rapid tests in the diagnosis of food poisoning. Good test performance levels were observed with rapid test methods, especially for polymerase chain reaction (PCR) assays. The estimated levels of diagnostic accuracy using the area under the curve of the summary receiver operating characteristic curve was very high. Indeed, although traditional culture is the natural reference test to use for comparative statistical analysis, on many occasions the rapid test outperforms culture, detecting additional 'truly' positive cases of food-borne illness. The significance of these additional positives requires further investigation. Economic modelling suggests that adoption of rapid tests in combination with routine culture is unlikely to be cost-effective, however, as the cost of rapid technologies decreases; total replacement with rapid technologies may be feasible. Despite the relatively poor quality of reporting of studies evaluating rapid detection methods, the reviewed evidence shows that PCR for Campylobacter, Salmonella and E. coli O157 is potentially very successful in identifying pathogens, possibly detecting more than the number currently reported using culture. Less is known about the benefits of testing for B. cereus, C. perfringens and S. aureus. Further investigation is needed on how clinical outcomes may be altered if test results are available more quickly and at a greater precision than in the current practice of bacterial culture.
What I make up when I wake up: anti-experience views and narrative fabrication of dreams.
Rosen, Melanie G
2013-01-01
I propose a narrative fabrication thesis of dream reports, according to which dream reports are often not accurate representations of experiences that occur during sleep. I begin with an overview of anti-experience theses of Norman Malcolm and Daniel Dennett who reject the received view of dreams, that dreams are experiences we have during sleep which are reported upon waking. Although rejection of the first claim of the received view, that dreams are experiences that occur during sleep, is implausible, I evaluate in more detail the second assumption of the received view, that dream reports are generally accurate. I then propose a "narrative fabrication" view of dreams as an alternative to the received view. Dream reports are often confabulated or fabricated because of poor memory, bizarre dream content, and cognitive deficits. It is well documented that narratives can be altered between initial rapid eye movement sleep awakenings and subsequent reports. I argue that we have reason to suspect that initial reports are prone to inaccuracy. Experiments demonstrate that subjects rationalize strange elements in narratives, leaving out supernatural or bizarre components when reporting waking memories of stories. Inaccuracies in dream reports are exacerbated by rapid memory loss and bizarre dream content. Waking memory is a process of reconstruction and blending of elements, but unlike waking memory, we cannot reality-test for dream memories. Dream experiences involve imaginative elements, and dream content cannot be verified with external evidence. Some dreams may involve wake-like higher cognitive functions, such as lucid dreams. Such dreams are more likely to elicit accurate reports than cognitively deficient dreams. However, dream reports are generally less accurate than waking reports. I then propose methods which could verify the narrative fabrication view, and argue that although the theory cannot be tested with current methods, new techniques and technologies may be able to do so in the future.
What I make up when I wake up: anti-experience views and narrative fabrication of dreams
Rosen, Melanie G.
2013-01-01
I propose a narrative fabrication thesis of dream reports, according to which dream reports are often not accurate representations of experiences that occur during sleep. I begin with an overview of anti-experience theses of Norman Malcolm and Daniel Dennett who reject the received view of dreams, that dreams are experiences we have during sleep which are reported upon waking. Although rejection of the first claim of the received view, that dreams are experiences that occur during sleep, is implausible, I evaluate in more detail the second assumption of the received view, that dream reports are generally accurate. I then propose a “narrative fabrication” view of dreams as an alternative to the received view. Dream reports are often confabulated or fabricated because of poor memory, bizarre dream content, and cognitive deficits. It is well documented that narratives can be altered between initial rapid eye movement sleep awakenings and subsequent reports. I argue that we have reason to suspect that initial reports are prone to inaccuracy. Experiments demonstrate that subjects rationalize strange elements in narratives, leaving out supernatural or bizarre components when reporting waking memories of stories. Inaccuracies in dream reports are exacerbated by rapid memory loss and bizarre dream content. Waking memory is a process of reconstruction and blending of elements, but unlike waking memory, we cannot reality-test for dream memories. Dream experiences involve imaginative elements, and dream content cannot be verified with external evidence. Some dreams may involve wake-like higher cognitive functions, such as lucid dreams. Such dreams are more likely to elicit accurate reports than cognitively deficient dreams. However, dream reports are generally less accurate than waking reports. I then propose methods which could verify the narrative fabrication view, and argue that although the theory cannot be tested with current methods, new techniques and technologies may be able to do so in the future. PMID:23964260
NASA Technical Reports Server (NTRS)
Rakoczy, John; Heater, Daniel; Lee, Ashley
2013-01-01
Marshall Space Flight Center's (MSFC) Small Projects Rapid Integration and Test Environment (SPRITE) is a Hardware-In-The-Loop (HWIL) facility that provides rapid development, integration, and testing capabilities for small projects (CubeSats, payloads, spacecraft, and launch vehicles). This facility environment focuses on efficient processes and modular design to support rapid prototyping, integration, testing and verification of small projects at an affordable cost, especially compared to larger type HWIL facilities. SPRITE (Figure 1) consists of a "core" capability or "plant" simulation platform utilizing a graphical programming environment capable of being rapidly re-configured for any potential test article's space environments, as well as a standard set of interfaces (i.e. Mil-Std 1553, Serial, Analog, Digital, etc.). SPRITE also allows this level of interface testing of components and subsystems very early in a program, thereby reducing program risk.
Chen, C P; Wan, J Z
1999-01-01
A fast learning algorithm is proposed to find an optimal weights of the flat neural networks (especially, the functional-link network). Although the flat networks are used for nonlinear function approximation, they can be formulated as linear systems. Thus, the weights of the networks can be solved easily using a linear least-square method. This formulation makes it easier to update the weights instantly for both a new added pattern and a new added enhancement node. A dynamic stepwise updating algorithm is proposed to update the weights of the system on-the-fly. The model is tested on several time-series data including an infrared laser data set, a chaotic time-series, a monthly flour price data set, and a nonlinear system identification problem. The simulation results are compared to existing models in which more complex architectures and more costly training are needed. The results indicate that the proposed model is very attractive to real-time processes.
Intelligent Scheduling for Underground Mobile Mining Equipment.
Song, Zhen; Schunnesson, Håkan; Rinne, Mikael; Sturgul, John
2015-01-01
Many studies have been carried out and many commercial software applications have been developed to improve the performances of surface mining operations, especially for the loader-trucks cycle of surface mining. However, there have been quite few studies aiming to improve the mining process of underground mines. In underground mines, mobile mining equipment is mostly scheduled instinctively, without theoretical support for these decisions. Furthermore, in case of unexpected events, it is hard for miners to rapidly find solutions to reschedule and to adapt the changes. This investigation first introduces the motivation, the technical background, and then the objective of the study. A decision support instrument (i.e. schedule optimizer for mobile mining equipment) is proposed and described to address this issue. The method and related algorithms which are used in this instrument are presented and discussed. The proposed method was tested by using a real case of Kittilä mine located in Finland. The result suggests that the proposed method can considerably improve the working efficiency and reduce the working time of the underground mine.
Software Development Of XML Parser Based On Algebraic Tools
NASA Astrophysics Data System (ADS)
Georgiev, Bozhidar; Georgieva, Adriana
2011-12-01
In this paper, is presented one software development and implementation of an algebraic method for XML data processing, which accelerates XML parsing process. Therefore, the proposed in this article nontraditional approach for fast XML navigation with algebraic tools contributes to advanced efforts in the making of an easier user-friendly API for XML transformations. Here the proposed software for XML documents processing (parser) is easy to use and can manage files with strictly defined data structure. The purpose of the presented algorithm is to offer a new approach for search and restructuring hierarchical XML data. This approach permits fast XML documents processing, using algebraic model developed in details in previous works of the same authors. So proposed parsing mechanism is easy accessible to the web consumer who is able to control XML file processing, to search different elements (tags) in it, to delete and to add a new XML content as well. The presented various tests show higher rapidity and low consumption of resources in comparison with some existing commercial parsers.
Study on Influencing Factor Analysis and Application of Consumer Mobile Commerce Acceptance
NASA Astrophysics Data System (ADS)
Li, Gaoguang; Lv, Tingjie
Mobile commerce (MC) refers to e-commerce activities carried out using a mobile device such as a phone or PDA. With new technology, MC will be rapidly growing in the near future. At the present time, what factors making consumer accept MC and what MC applications are acceptable by consumers are two of hot issues both for MC providers and f or MC researchers. This study presents a proposed MC acceptance model that integrates perceived playfulness, perceived risk and cost into the TAM to study which factors affect consumer MC acceptance. The proposed model includes five variables, namely perceived risk, cost, perceived usefulness, perceived playfulness, perceived ease of use, perceived playfulness. Then, using analytic hierarchy process (AHP) to calculate weight of criteria involved in proposed model. Finally, the study utilizes fuzzy comprehensive evaluation method to evaluate MC applications accepted possibility, and then a MC application is empirically tested using data collected from a survey of MC consumers.
Development of method for quantifying essential tremor using a small optical device.
Chen, Kai-Hsiang; Lin, Po-Chieh; Chen, Yu-Jung; Yang, Bing-Shiang; Lin, Chin-Hsien
2016-06-15
Clinical assessment scales are the most common means used by physicians to assess tremor severity. Some scientific tools that may be able to replace these scales to objectively assess the severity, such as accelerometers, digital tablets, electromyography (EMG) measurement devices, and motion capture cameras, are currently available. However, most of the operational modes of these tools are relatively complex or are only able to capture part of the clinical information; furthermore, using these tools is sometimes time consuming. Currently, there is no tool available for automatically quantifying tremor severity in clinical environments. We aimed to develop a rapid, objective, and quantitative system for measuring the severity of finger tremor using a small portable optical device (Leap Motion). A single test took 15s to conduct, and three algorithms were proposed to quantify the severity of finger tremor. The system was tested with four patients diagnosed with essential tremor. The proposed algorithms were able to quantify different characteristics of tremor in clinical environments, and could be used as references for future clinical assessments. A portable, easy-to-use, small-sized, and noncontact device (Leap Motion) was used to clinically detect and record finger movement, and three algorithms were proposed to describe tremor amplitudes. Copyright © 2016 Elsevier B.V. All rights reserved.
Nelson, Scott D; Del Fiol, Guilherme; Hanseler, Haley; Crouch, Barbara Insley; Cummins, Mollie R
2016-01-01
Health information exchange (HIE) between Poison Control Centers (PCCs) and Emergency Departments (EDs) could improve care of poisoned patients. However, PCC information systems are not designed to facilitate HIE with EDs; therefore, we are developing specialized software to support HIE within the normal workflow of the PCC using user-centered design and rapid prototyping. To describe the design of an HIE dashboard and the refinement of user requirements through rapid prototyping. Using previously elicited user requirements, we designed low-fidelity sketches of designs on paper with iterative refinement. Next, we designed an interactive high-fidelity prototype and conducted scenario-based usability tests with end users. Users were asked to think aloud while accomplishing tasks related to a case vignette. After testing, the users provided feedback and evaluated the prototype using the System Usability Scale (SUS). Survey results from three users provided useful feedback that was then incorporated into the design. After achieving a stable design, we used the prototype itself as the specification for development of the actual software. Benefits of prototyping included having 1) subject-matter experts heavily involved with the design; 2) flexibility to make rapid changes, 3) the ability to minimize software development efforts early in the design stage; 4) rapid finalization of requirements; 5) early visualization of designs; 6) and a powerful vehicle for communication of the design to the programmers. Challenges included 1) time and effort to develop the prototypes and case scenarios; 2) no simulation of system performance; 3) not having all proposed functionality available in the final product; and 4) missing needed data elements in the PCC information system.
Sergueev, Kirill V; He, Yunxiu; Borschel, Richard H; Nikolich, Mikeljon P; Filippov, Andrey A
2010-06-28
Yersinia pestis, the agent of plague, has caused many millions of human deaths and still poses a serious threat to global public health. Timely and reliable detection of such a dangerous pathogen is of critical importance. Lysis by specific bacteriophages remains an essential method of Y. pestis detection and plague diagnostics. The objective of this work was to develop an alternative to conventional phage lysis tests--a rapid and highly sensitive method of indirect detection of live Y. pestis cells based on quantitative real-time PCR (qPCR) monitoring of amplification of reporter Y. pestis-specific bacteriophages. Plague diagnostic phages phiA1122 and L-413C were shown to be highly effective diagnostic tools for the detection and identification of Y. pestis by using qPCR with primers specific for phage DNA. The template DNA extraction step that usually precedes qPCR was omitted. phiA1122-specific qPCR enabled the detection of an initial bacterial concentration of 10(3) CFU/ml (equivalent to as few as one Y. pestis cell per 1-microl sample) in four hours. L-413C-mediated detection of Y. pestis was less sensitive (up to 100 bacteria per sample) but more specific, and thus we propose parallel qPCR for the two phages as a rapid and reliable method of Y. pestis identification. Importantly, phiA1122 propagated in simulated clinical blood specimens containing EDTA and its titer rise was detected by both a standard plating test and qPCR. Thus, we developed a novel assay for detection and identification of Y. pestis using amplification of specific phages monitored by qPCR. The method is simple, rapid, highly sensitive, and specific and allows the detection of only live bacteria.
Clinically expedient reporting of rapid diagnostic test information.
Doern, G V
1986-03-01
With the development of rapid diagnostic tests in the clinical microbiology laboratory has come an awareness of the importance of rapid results reporting. Clearly, the potential clinical impact of rapid diagnostic tests is dependent on expeditious reporting. Traditional manual reporting systems are encumbered by the necessity of transcription of test information onto hard copy reports and then the subsequent distribution of such reports into the hands of the user. Laboratory computers when linked directly to CRTs located in nursing stations, ambulatory clinics, or physician's offices, both inside and outside of the hospital, permit essentially instantaneous transfer of test results from the laboratory to the clinician. Computer-assisted results reporting, while representing a significant advance over manual reporting systems is not, however, without problems. Concerns include validation of test information, authorization of users with access to test information, mechanical integrity, and cost. These issues notwithstanding, computerized results reporting will undoubtedly play a central role in optimizing the clinical impact of rapid diagnostic tests.
Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)
2008-12-01
the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.
Peng, Bing; Zhang, Li; Yan, Jianying; Qi, Hongbo; Zhang, Weiyuan; Fan, Ling; Hu, Yayi; Lin, Li; Li, Xiaotian; Hu, Rong; Xie, Lan; Zhang, Jianping; Wu, Yanqiao; Li, Li; Zhou, Rong
2017-01-01
The purpose of the present study was to evaluate the clinical value of the rapid strip test of urinary adipsin for the quick diagnosis of pre-eclampsia. In a multicenter diagnostic test study, we studied the diagnostic accuracy of the rapid strip test of urinary adipsin in women presenting with pre-eclampsia. A total of 204 pre-eclampsia patients and 254 healthy pregnant women were recruited for this study, respectively. The rapid strip test of urinary adipsin was used to detect the adipsin in the urine of each patient. The diagnostic value of the rapid strip test of urinary adipsin for pre-eclampsia was demonstrated by its high sensitivity and specificity (95.10% and 97.64%, respectively). The diagnostic accuracy was 96.51%. The consistency analysis showed that the kappa value was 0.93 compared with the gold standard diagnosis of pre-eclampsia. The rapid strip test of urinary adipsin is a non-invasive test for the diagnosis of pre-eclampsia with high sensitivity and specificity. It could help the quick diagnosis of pre-eclampsia in clinical practice greatly. © 2016 Japan Society of Obstetrics and Gynecology.
Code of Federal Regulations, 2011 CFR
2011-01-01
... microagglutination test, the enzyme-linked immunosorbent assay test (ELISA), or the rapid serum test for all poultry... react on rapid serum test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that... inhibition (HI) test, the microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA...
Metal artifact reduction using a patch-based reconstruction for digital breast tomosynthesis
NASA Astrophysics Data System (ADS)
Borges, Lucas R.; Bakic, Predrag R.; Maidment, Andrew D. A.; Vieira, Marcelo A. C.
2017-03-01
Digital breast tomosynthesis (DBT) is rapidly emerging as the main clinical tool for breast cancer screening. Although several reconstruction methods for DBT are described by the literature, one common issue is the interplane artifacts caused by out-of-focus features. For breasts containing highly attenuating features, such as surgical clips and large calcifications, the artifacts are even more apparent and can limit the detection and characterization of lesions by the radiologist. In this work, we propose a novel method of combining backprojected data into tomographic slices using a patch-based approach, commonly used in denoising. Preliminary tests were performed on a geometry phantom and on an anthropomorphic phantom containing metal inserts. The reconstructed images were compared to a commercial reconstruction solution. Qualitative assessment of the reconstructed images provides evidence that the proposed method reduces artifacts while maintaining low noise levels. Objective assessment supports the visual findings. The artifact spread function shows that the proposed method is capable of suppressing artifacts generated by highly attenuating features. The signal difference to noise ratio shows that the noise levels of the proposed and commercial methods are comparable, even though the commercial method applies post-processing filtering steps, which were not implemented on the proposed method. Thus, the proposed method can produce tomosynthesis reconstructions with reduced artifacts and low noise levels.
Al-Tayar, Naef Ghllab Saeed; Nagaraja, P; Vasantha, R A; Shresta, Ashwinee Kumar
2012-01-01
A simple, rapid, and sensitive method involving the interaction of 2,4-dinitrophenylhydrazine with imipramine hydrochloride in presence of vanadium (V) in sulfuric acid medium has been proposed for the determination of vanadium. The purple-colored product developed showed an absorption maximum at 560 nm and was stable for 24 h. The working curve was linear over the concentration range of 0.1-2.8 μg ml( - 1), with sensitivity of detection of 0.0124 μg ml( - 1). Molar absorptivity and Sandell's sensitivity were found to be 2.6 × 10(4) l/mol cm and 0.0039 μg cm( - 1), respectively. The accuracy of the proposed method was assessed by Student's t test and variance ratio F test, and the results were on par with the reported method. The method was successfully used in the determination of V in water, human urine, soil, and plant samples, and it was free from interference by various concomitant ions.
Lobatón, Triana; Rodríguez-Moranta, Francisco; Lopez, Alicia; Sánchez, Elena; Rodríguez-Alonso, Lorena; Guardiola, Jordi
2013-04-01
Fecal calprotectin (FC) determined by the enzyme-linked immunosorbent assay (ELISA) test has been proposed as a promising biomarker of endoscopic activity in ulcerative colitis (UC). However, data on its accuracy in predicting endoscopic activity is scarce. Besides, FC determined by the quantitative-point-of-care test (FC-QPOCT) that provides rapid and individual results could optimize its use in clinical practice. The aims of our study were to evaluate the ability of FC to predict endoscopic activity according to the Mayo score in patients with UC when determined by FC-QPOCT and to compare it with the ELISA test (FC-ELISA). FC was determined simultaneously by FC-ELISA and FC-QPOCT in patients with UC undergoing colonoscopy. Clinical disease activity and endoscopy were assessed according to the Mayo score. Blood tests were taken to analyze serological biomarkers. A total of 146 colonoscopies were performed on 123 patients with UC. FC-QPOCT correlated more closely with the Mayo endoscopic subscore (Spearman's correlation coefficient rank r = 0.727, P < 0.001) than clinical activity (r = 0.636, P < 0.001), platelets (r = 0.381, P < 0.001), leucocytes (r = 0.300, P < 0.001), and C-reactive protein (r = 0.291, P = 0.002). The prediction of "endoscopic remission" (Mayo endoscopic subscore ≤1) with FC-QPOCT (280 µg/g) and FC-ELISA (250 µg/g) presented an area under the curve of 0.906 and 0.924, respectively. The interclass correlation index between both tests was 0.904 (95% confidence interval, 0.864-0.932; P < 0.001). FC determined by QPOCT was an accurate surrogate marker of "endoscopic remission" in UC and presented a good correlation with the FC-ELISA test.
NASA Astrophysics Data System (ADS)
Zhang, Jinfang; Yan, Xiaoqing; Wang, Hongfu
2018-02-01
With the rapid development of renewable energy in Northwest China, curtailment phenomena is becoming more and more serve owing to lack of adjustment ability and enough transmission capacity. Based on the existing HVDC projects, exploring the hybrid transmission mode associated with thermal power and renewable power will be necessary and important. This paper has proposed a method on optimal thermal power and renewable energy combination for HVDC lines, based on multi-scheme comparison. Having established the mathematic model for electric power balance in time series mode, ten different schemes have been picked for figuring out the suitable one by test simulation. By the proposed related discriminated principle, including generation device utilization hours, renewable energy electricity proportion and curtailment level, the recommendation scheme has been found. The result has also validated the efficiency of the method.
3 x 3 free-space optical router based on crossbar network and its control algorithm
NASA Astrophysics Data System (ADS)
Hou, Peipei; Sun, Jianfeng; Yu, Zhou; Lu, Wei; Wang, Lijuan; Liu, Liren
2015-08-01
A 3 × 3 free-space optical router, which comprises optical switches and polarizing beam splitter (PBS) and based on crossbar network, is proposed in this paper. A control algorithm for the 3 × 3 free-space optical router is also developed to achieve rapid control without rearrangement. In order to test the performance of the network based on 3 × 3 free-space optical router and that of the algorithm developed for the optical router, experiments are designed. The experiment results show that the interconnection network based on the 3 × 3 free-space optical router has low cross talk, fast connection speed. Under the control of the algorithm developed, a non-block and real free interconnection network is obtained based on the 3 × 3 free-space optical router we proposed.
Privacy preserving processing of genomic data: A survey.
Akgün, Mete; Bayrak, A Osman; Ozer, Bugra; Sağıroğlu, M Şamil
2015-08-01
Recently, the rapid advance in genome sequencing technology has led to production of huge amount of sensitive genomic data. However, a serious privacy challenge is confronted with increasing number of genetic tests as genomic data is the ultimate source of identity for humans. Lately, privacy threats and possible solutions regarding the undesired access to genomic data are discussed, however it is challenging to apply proposed solutions to real life problems due to the complex nature of security definitions. In this review, we have categorized pre-existing problems and corresponding solutions in more understandable and convenient way. Additionally, we have also included open privacy problems coming with each genomic data processing procedure. We believe our classification of genome associated privacy problems will pave the way for linking of real-life problems with previously proposed methods. Copyright © 2015 Elsevier Inc. All rights reserved.
Progress and Challenges of Ultrasonic Testing for Stress in Remanufacturing Laser Cladding Coating
Yan, Xiao-Ling; Dong, Shi-Yun; Xu, Bin-Shi; Cao, Yong
2018-01-01
Stress in laser cladding coating is an important factor affecting the safe operation of remanufacturing components. Ultrasonic testing has become a popular approach in the nondestructive evaluation of stress, because it has the advantages of safety, nondestructiveness, and online detection. This paper provides a review of ultrasonic testing for stress in remanufacturing laser cladding coating. It summarizes the recent research outcomes on ultrasonic testing for stress, and analyzes the mechanism of ultrasonic testing for stress. Remanufacturing laser cladding coating shows typical anisotropic behaviors. The ultrasonic testing signal in laser cladding coating is influenced by many complex factors, such as microstructure, defect, temperature, and surface roughness, among others. At present, ultrasonic testing for stress in laser cladding coating can only be done roughly. This paper discusses the active mechanism of micro/macro factors in the reliability of stress measurement, as well as the impact of stress measurement on the quality and safety of remanufacturing components. Based on the discussion, this paper proposes strategies to nondestructively, rapidly, and accurately measure stress in remanufacturing laser cladding coating. PMID:29438309
Progress and Challenges of Ultrasonic Testing for Stress in Remanufacturing Laser Cladding Coating.
Yan, Xiao-Ling; Dong, Shi-Yun; Xu, Bin-Shi; Cao, Yong
2018-02-13
Stress in laser cladding coating is an important factor affecting the safe operation of remanufacturing components. Ultrasonic testing has become a popular approach in the nondestructive evaluation of stress, because it has the advantages of safety, nondestructiveness, and online detection. This paper provides a review of ultrasonic testing for stress in remanufacturing laser cladding coating. It summarizes the recent research outcomes on ultrasonic testing for stress, and analyzes the mechanism of ultrasonic testing for stress. Remanufacturing laser cladding coating shows typical anisotropic behaviors. The ultrasonic testing signal in laser cladding coating is influenced by many complex factors, such as microstructure, defect, temperature, and surface roughness, among others. At present, ultrasonic testing for stress in laser cladding coating can only be done roughly. This paper discusses the active mechanism of micro/macro factors in the reliability of stress measurement, as well as the impact of stress measurement on the quality and safety of remanufacturing components. Based on the discussion, this paper proposes strategies to nondestructively, rapidly, and accurately measure stress in remanufacturing laser cladding coating.
Heaney, Jennifer L J; Campbell, John P; Yadav, Punit; Griffin, Ann E; Shemar, Meena; Pinney, Jennifer H; Drayson, Mark T
2017-07-20
Acute kidney injury (AKI) is common in patients with multiple myeloma (MM). Whether serum free light chain (sFLC) measurements can distinguish between myeloma and other causes of AKI requires confirmation to guide early treatment. A rapid and portable sFLC test (Seralite®) is newly available and could reduce delays in obtaining sFLC results and accelerate diagnosis in patients with unexplained AKI. This study evaluated the accuracy of Seralite® to identify MM as the cause of AKI. sFLCs were retrospectively analysed in patients with AKI stage 3 as per KDIGO criteria (i.e. serum creatinine ≥354 μmol/L or those on dialysis treatment) (n = 99); 45/99 patients had a confirmed MM diagnosis. The Seralite® κ:λ FLC ratio accurately diagnosed all MM patients in the presence of AKI: a range of 0.14-2.02 returned 100% sensitivity and specificity for identifying all non-myeloma related AKI patients. The sFLC difference (dFLC) also demonstrated high sensitivity (91%) and specificity (100%): an optimal cut-off of 399 mg/L distinguished between myeloma and non-myeloma AKI patients. We propose a pathway of patient screening and stratification in unexplained AKI for use of Seralite® in clinical practice, with a κ:λ ratio range of 0.14-2.02 and dFLC 400 mg/L as decision points. Seralite® accurately differentiates between AKI due to MM and AKI due to other causes in patients considered at risk of myeloma. This rapid test can sensitively screen for MM in patients with AKI and help inform early treatment intervention.
NASA Astrophysics Data System (ADS)
Nurjayadi, M.; Santoso, I.; Kartika, I. R.; Kurniadewi, F.; Saamia, V.; Sofihan, W.; Nurkhasanah, D.
2017-07-01
There is a lot of public concern over food safety. Food-safety cases recently, including many food poisoning cases in both the developed and developing countries, considered to be the national security threats which involved police investigation. Quick and accurate detection methods are needed to handle the food poisoning cases with a big number of sufferers at the same time. Therefore, the research is aimed to develop a specific, sensitive, and rapid result molecular detection tool for foodborne pathogen bacteria. We, thus, propose genomic level approach with Polymerase Chain Reaction. The research has successfully produced a specific primer to perform amplification to fim-C S. typhi, E. coli, and pef Salmonella typhimurium genes. The electrophoresis result shows that amplification products are 95 base pairs, 121 base pairs, and 139 base pairs; and all three genes are in accordance with the size of the in silico to third genes bacteria. In conclusion, the research has been successfully designed a specific detection tool to three foodborne pathogen bacteria genes. Further stages test and the uses of Real-time PCR in the detection are still in the trial process for better detection method.
Hammouda, Mohammed E. A.; Abu El-Enin, Mohamed A.; El-Sherbiny, Dina T.; El-Wasseef, Dalia R.; El-Ashry, Saadia M.
2013-01-01
A rapid HPLC procedure using a microemulsion as an eluent was developed and validated for analytical quality control of antihyperlipidemic mixture containing simvastatin (SIM) and ezetimibe (EZT) in their pharmaceutical preparations. The separation was performed on a column packed with cyano bonded stationary phase adopting UV detection at 238 nm using a flow rate of 1 mL/min. The optimized microemulsion mobile phase consisted of 0.2 M sodium dodecyl sulphate, 1% octanol, 10% n-propanol, and 0.3% triethylamine in 0.02 M phosphoric acid at pH 5.0. The developed method was validated in terms of specificity, linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), precision, and accuracy. The proposed method is rapid (8.5 min), reproducible (RSD < 2.0%) and achieves satisfactory resolution between SIM and EZT (resolution factor = 2.57). The mean recoveries of the analytes in pharmaceutical preparations were in agreement with those obtained from a reference method, as revealed by statistical analysis of the obtained results using Student's t-test and the variance ratio F-test. PMID:24282651
Guo, Pengqi; Xu, Xinya; Xian, Liang; Ge, Yanhui; Luo, Zhimin; Du, Wei; Jing, Wanghui; Zeng, Aiguo; Chang, Chun; Fu, Qiang
2016-12-01
Nowadays, the illegal use of estradiol in cosmetics has caused a series of events which endangering public health seriously. Therefore, it is imperative to establish a simple, fast and specific method for monitoring the illegal use of estradiol in cosmetics. In current study, we developed a molecular imprinted monolithic column two dimensional liquid chromatography method (MIMC-2D-LC) for rapid and selective determination of estradiol in various cosmetic samples. The best polymerization, morphology, structure property, surface groups, and the adsorption performance of the prepared material were investigated. The MIMC-2D-LC was validated and successfully used for detecting estradiol in cosmetic samples with good selectivity, sensitivity, efficiency and reproducibility. The linear range of the MIMC-2D-LC for estradiol was 0.5-50μgg -1 with the limit of detection of 0.08μgg -1 . Finally, six batches of cosmetic samples obtained from local markets were tested by the proposed method. The test results showed that the illegal use of estradiol still existed in the commercially available samples. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Field, K. G.; Wetteland, C. J.; Cao, G.
2013-04-19
The University of Wisconsin Ion Beam Laboratory (UW-IBL) has recently undergone significant infrastructure upgrades to facilitate graduate level research in irradiated materials phenomena and ion beam analysis. A National Electrostatics Corp. (NEC) Torodial Volume Ion Source (TORVIS), the keystone upgrade for the facility, can produce currents of hydrogen ions and helium ions up to {approx}200 {mu}A and {approx}5 {mu}A, respectively. Recent upgrades also include RBS analysis packages, end station developments for irradiation of relevant material systems, and the development of an in-house touch screen based graphical user interface for ion beam monitoring. Key research facilitated by these upgrades includes irradiationmore » of nuclear fuels, studies of interfacial phenomena under irradiation, and clustering dynamics of irradiated oxide dispersion strengthened steels. The UW-IBL has also partnered with the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) to provide access to the irradiation facilities housed at the UW-IBL as well as access to post irradiation facilities housed at the UW Characterization Laboratory for Irradiated Materials (CLIM) and other ATR-NSUF partner facilities. Partnering allows for rapid turnaround from proposed research to finalized results through the ATR-NSUF rapid turnaround proposal system. An overview of the UW-IBL including CLIM and relevant research is summarized.« less
Multispectral digital holographic microscopy with applications in water quality assessment
NASA Astrophysics Data System (ADS)
Kazemzadeh, Farnoud; Jin, Chao; Yu, Mei; Amelard, Robert; Haider, Shahid; Saini, Simarjeet; Emelko, Monica; Clausi, David A.; Wong, Alexander
2015-09-01
Safe drinking water is essential for human health, yet over a billion people worldwide do not have access to safe drinking water. Due to the presence and accumulation of biological contaminants in natural waters (e.g., pathogens and neuro-, hepato-, and cytotoxins associated with algal blooms) remain a critical challenge in the provision of safe drinking water globally. It is not financially feasible and practical to monitor and quantify water quality frequently enough to identify the potential health risk due to contamination, especially in developing countries. We propose a low-cost, small-profile multispectral (MS) system based on Digital Holographic Microscopy (DHM) and investigate methods for rapidly capturing holographic data of natural water samples. We have developed a test-bed for an MSDHM instrument to produce and capture holographic data of the sample at different wavelengths in the visible and the near Infra-red spectral region, allowing for resolution improvement in the reconstructed images. Additionally, we have developed high-speed statistical signal processing and analysis techniques to facilitate rapid reconstruction and assessment of the MS holographic data being captured by the MSDHM instrument. The proposed system is used to examine cyanobacteria as well as Cryptosporidium parvum oocysts which remain important and difficult to treat microbiological contaminants that must be addressed for the provision of safe drinking water globally.
2017-07-07
RESEARCH ARTICLE Self-reported HIV-positive status but subsequent HIV-negative test result using rapid diagnostic testing algorithms among seven sub...America * judith.harbertson.ctr@mail.mil Abstract HIV rapid diagnostic tests (RDTs) combined in an algorithm are the current standard for HIV diagnosis...in many sub-Saharan African countries, and extensive laboratory testing has con- firmed HIV RDTs have excellent sensitivity and specificity. However
Athanasiou, Labrini V; Petanides, Theodoros A; Chatzis, Manolis K; Kasabalis, Dimitrios; Apostolidis, Kosmas N; Saridomichelakis, Manolis N
2014-03-01
Antibodies against Leishmania spp. are detected in most dogs with clinical signs of leishmaniasis due to Leishmania infantum. Accurate, rapid in-clinic serological tests may permit immediate confirmation of the diagnosis and implementation of therapeutic measures. The aim of the current study was to evaluate the diagnostic accuracy of 2 commercial, rapid in-clinic serological tests for the detection of anti-Leishmania antibodies in sera of dogs, the Snap Canine Leishmania Antibody Test kit (IDEXX Laboratories Inc., Westbrook, Maine) and the ImmunoRun Antibody Detection kit (Biogal Galed Labs, Kibbutz Galed, Israel), using indirect fluorescent antibody test (IFAT) as the reference method. A total of 109 sera collected from 65 seropositive and 44 seronegative dogs were used. The sensitivities of the Snap and ImmunoRun kits were 89.23% (95% confidence interval: 79.05-95.54%) and 86.15% (95% confidence interval: 75.33-93.45%), respectively, and the specificity of both tests was 100%. A good agreement between each of the rapid in-clinic serological tests and IFAT and between the 2 rapid in-clinic serological tests was witnessed. Both rapid in-clinic serological tests showed an adequate diagnostic accuracy and can be used for the fast detection of antibodies against L. infantum in dogs.
Hoyer, Annika; Kuss, Oliver
2018-05-01
Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.
Artificial intelligence techniques for embryo and oocyte classification.
Manna, Claudio; Nanni, Loris; Lumini, Alessandra; Pappalardo, Sebastiana
2013-01-01
One of the most relevant aspects in assisted reproduction technology is the possibility of characterizing and identifying the most viable oocytes or embryos. In most cases, embryologists select them by visual examination and their evaluation is totally subjective. Recently, due to the rapid growth in the capacity to extract texture descriptors from a given image, a growing interest has been shown in the use of artificial intelligence methods for embryo or oocyte scoring/selection in IVF programmes. This work concentrates the efforts on the possible prediction of the quality of embryos and oocytes in order to improve the performance of assisted reproduction technology, starting from their images. The artificial intelligence system proposed in this work is based on a set of Levenberg-Marquardt neural networks trained using textural descriptors (the local binary patterns). The proposed system was tested on two data sets of 269 oocytes and 269 corresponding embryos from 104 women and compared with other machine learning methods already proposed in the past for similar classification problems. Although the results are only preliminary, they show an interesting classification performance. This technique may be of particular interest in those countries where legislation restricts embryo selection. One of the most relevant aspects in assisted reproduction technology is the possibility of characterizing and identifying the most viable oocytes or embryos. In most cases, embryologists select them by visual examination and their evaluation is totally subjective. Recently, due to the rapid growth in our capacity to extract texture descriptors from a given image, a growing interest has been shown in the use of artificial intelligence methods for embryo or oocyte scoring/selection in IVF programmes. In this work, we concentrate our efforts on the possible prediction of the quality of embryos and oocytes in order to improve the performance of assisted reproduction technology, starting from their images. The artificial intelligence system proposed in this work is based on a set of Levenberg-Marquardt neural networks trained using textural descriptors (the 'local binary patterns'). The proposed system is tested on two data sets, of 269 oocytes and 269 corresponding embryos from 104 women, and compared with other machine learning methods already proposed in the past for similar classification problems. Although the results are only preliminary, they showed an interesting classification performance. This technique may be of particular interest in those countries where legislation restricts embryo selection. Copyright © 2012 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Shuiqiang; Mao, Shuangshuang; Arola, Dwayne; Zhang, Dongsheng
2014-09-01
Characterizing the strain-life fatigue behavior of thin sheet metals is often challenging since the required specimens have short gauge lengths to avoid buckling, thereby preventing the use of conventional mechanical extensometers. To overcome this obstacle a microscopic optical imaging system has been developed to measure the strain amplitude during fatigue testing using Digital Image Correlation (DIC). A strategy for rapidly recording images is utilized to enable sequential image sampling rates of at least 10 frames per second (fps) using a general digital camera. An example of a complete strain-life fatigue test for thin sheet steel under constant displacement control is presented in which the corresponding strain within the gage section of the specimen is measured using the proposed imaging system. The precision in strain measurement is assessed and methods for improving the image sampling rates in dynamic testing are discussed.
2012 HIV Diagnostics Conference: the molecular diagnostics perspective.
Branson, Bernard M; Pandori, Mark
2013-04-01
2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.
An acute study on the relative gastro-intestinal absorption of a novel form of calcium ascorbate.
Bush, M J; Verlangieri, A J
1987-07-01
Several functions of L-ascorbic acid (vitamin C) have been suggested in addition to its role in the prevention of scurvy. Consequently, a controversy has arisen over the daily intake of the vitamin which will afford maximum benefits. Rapid cellular uptake and delayed renal excretion of ascorbic acid would be conducive to providing optimum cellular concentration for biochemical activity. ESTER-C (patent pending), a complex consisting of L-ascorbic acid and Ca++, has been recently developed by Inter-Cal Corporation (421 Miller Road, Prescott, AZ 86301). It has been proposed that the structure of ESTER-C may render it more readily absorbed and less rapidly excreted than the acid or salt form of the vitamin. To test this hypothesis, ESTER-C and L-ascorbic acid were administered to two groups of rats. Blood was sampled at 20, 40, 80, 160 and 240 minutes and plasma analyzed for ascorbic acid. As urine appeared in collection cups, it was tested qualitatively for the presence of ascorbic acid. The plasma concentration of ascorbic acid was higher in ESTER-C treated rats at 20, 40 and 80 minutes than in rats given L-ascorbic acid. Ascorbic acid was detected in the urine of animals administered ESTER-C later than in those treated with L-ascorbic acid. These results support the hypothesis that ESTER-C is absorbed more readily and excreted less rapidly than L-ascorbic acid.
Rapid Structural Design Change Evaluation with AN Experiment Based FEM
NASA Astrophysics Data System (ADS)
Chu, C.-H.; Trethewey, M. W.
1998-04-01
The work in this paper proposes a dynamic structural design model that can be developed in a rapid fashion. The approach endeavours to produce a simplified FEM developed in conjunction with an experimental modal database. The FEM is formulated directly from the geometry and connectivity used in an experimental modal test using beam/frame elements. The model sacrifices fine detail for a rapid development time. The FEM is updated at the element level so the dynamic response replicates the experimental results closely. The physical attributes of the model are retained, making it well suited to evaluate the effect of potential design changes. The capabilities are evaluated in a series of computational and laboratory tests. First, a study is performed with a simulated cantilever beam with a variable mass and stiffness distribution. The modal characteristics serve as the updating target with random noise added to simulate experimental uncertainty. A uniformly distributed FEM is developed and updated. The results show excellent results, all natural frequencies are within 0·001% with MAC values above 0·99. Next, the method is applied to predict the dynamic changes of a hardware portal frame structure for a radical design change. Natural frequency predictions from the original FEM differ by as much as almost 18% with reasonable MAC values. The results predicted from the updated model produce excellent results when compared to the actual hardware changes, the first five modal natural frequency difference is around 5% and the corresponding mode shapes producing MAC values above 0·98.
Infrared Submillimeter and Radio Astronomy Research and Analysis Program
NASA Technical Reports Server (NTRS)
Traub, Wesley A.
2000-01-01
This program entitled "Infrared Submillimeter and Radio Astronomy Research and Analysis Program" with NASA-Ames Research Center (ARC) was proposed by the Smithsonian Astrophysical Observatory (SAO) to cover three years. Due to funding constraints only the first year installment of $18,436 was funded, but this funding was spread out over two years to try to maximize the benefit to the program. During the tenure of this contact, the investigators at the SAO, Drs. Wesley A. Traub and Nathaniel P. Carleton, worked with the investigators at ARC, Drs. Jesse Bregman and Fred Wittebom, on the following three main areas: 1. Rapid scanning SAO and ARC collaborated on purchasing and constructing a Rapid Scan Platform for the delay arm of the Infrared-Optical Telescope Array (IOTA) interferometer on Mt. Hopkins, Arizona. The Rapid Scan Platform was tested and improved by the addition of stiffening plates which eliminated a very small but noticeable bending of the metal platform at the micro-meter level. 2. Star tracking Bregman and Wittebom conducted a study of the IOTA CCD-based star tracker system, by constructing a device to simulate star motion having a specified frequency and amplitude of motion, and by examining the response of the tracker to this simulated star input. 3. Fringe tracking. ARC, and in particular Dr. Robert Mah, developed a fringe-packet tracking algorithm, based on data that Bregman and Witteborn obtained on IOTA. The algorithm was tested in the laboratory at ARC, and found to work well for both strong and weak fringes.
Strep Test: Rapid (For Parents)
... third of negative rapid strep test results are false (meaning someone actually has a strep throat infection even though the rapid strep results were negative). A throat culture may then be done to ensure accuracy. Risks ...
A Novel Technique for Detecting Antibiotic-Resistant Typhoid from Rapid Diagnostic Tests
Nic Fhogartaigh, Caoimhe; Dance, David A. B.; Davong, Viengmon; Tann, Pisey; Phetsouvanh, Rattanaphone; Turner, Paul; Newton, Paul N.
2015-01-01
Fluoroquinolone-resistant typhoid is increasing. An antigen-detecting rapid diagnotic test (RDT) can rapidly diagnose typhoid from blood cultures. A simple, inexpensive molecular technique performed with DNA from positive RDTs accurately identified gyrA mutations consistent with phenotypic susceptibility testing results. Field diagnosis combined with centralized molecular resistance testing could improve typhoid management and surveillance in low-resource settings. PMID:25762768
Actuated Hybrid Mirrors for Space Telescopes
NASA Technical Reports Server (NTRS)
Hickey, Gregory; Ealey, Mark; Redding, David
2010-01-01
This paper describes new, large, ultra-lightweight, replicated, actively controlled mirrors, for use in space telescopes. These mirrors utilize SiC substrates, with embedded solid-state actuators, bonded to Nanolaminate metal foil reflective surfaces. Called Actuated Hybrid Mirrors (AHMs), they use replication techniques for high optical quality as well as rapid, low cost manufacturing. They enable an Active Optics space telescope architecture that uses periodic image-based wavefront sensing and control to assure diffraction-limited performance, while relaxing optical system fabrication, integration and test requirements. The proposed International Space Station Observatory seeks to demonstrate this architecture in space.
Correlation of dissolution and disintegration results for an immediate-release tablet.
Nickerson, Beverly; Kong, Angela; Gerst, Paul; Kao, Shangming
2018-02-20
The drug release rate of a rapidly dissolving immediate-release tablet formulation with a highly soluble drug is proposed to be controlled by the disintegration rate of the tablet. Disintegration and dissolution test methods used to evaluate the tablets were shown to discriminate manufacturing process differences and compositionally variant tablets. In addition, a correlation was established between disintegration and dissolution. In accordance with ICH Q6A, this work demonstrates that disintegration in lieu of dissolution is suitable as the drug product quality control method for evaluating this drug product. Copyright © 2017 Elsevier B.V. All rights reserved.
Constant amplitude and post-overload fatigue crack growth behavior in PM aluminum alloy AA 8009
NASA Technical Reports Server (NTRS)
Reynolds, A. P.
1992-01-01
A recently developed, rapidly solidified, powder metallurgy, dispersion strengthened aluminum alloy, AA 8009, was fatigue tested at room temperature in lab air. Constant amplitude/constant delta kappa and single spike overload conditions were examined. High fatigue crack growth rates and low crack closure levels compared to typical ingot metallurgy aluminum alloys were observed. It was proposed that minimal crack roughness, crack path delection, and limited slip reversibility, resulting from ultra-fine microstructure, were responsible for the relatively poor da/dN-delta kappa performance of AA 8009 as compared to that of typical IM aluminum alloys.
Constant amplitude and post-overload fatigue crack growth behavior in PM aluminum alloy AA 8009
NASA Technical Reports Server (NTRS)
Reynolds, A. P.
1991-01-01
A recently developed, rapidly solidified, powder metallurgy, dispersion strengthened aluminum alloy, AA 8009, was fatigue tested at room temperature in lab air. Constant amplitude/constant delta kappa and single spike overload conditions were examined. High fatigue crack growth rates and low crack closure levels compared to typical ingot metallurgy aluminum alloys were observed. It was proposed that minimal crack roughness, crack path deflection, and limited slip reversibility, resulting from ultra-fine microstructure, were responsible for the relatively poor da/dN-delta kappa performance of AA 8009 as compared to that of typical IM aluminum alloys.
NASA Technical Reports Server (NTRS)
Herb, G. T.
1973-01-01
Two areas of a laser range finder for a Mars roving vehicle are investigated: (1) laser scanning systems, and (2) range finder methods and implementation. Several ways of rapidly scanning a laser are studied. Two digital deflectors and a matrix of laser diodes, are found to be acceptable. A complete range finder scanning system of high accuracy is proposed. The problem of incident laser spot distortion on the terrain is discussed. The instrumentation for a phase comparison, modulated laser range finder is developed and sections of it are tested.
Munshi, Saif U; Oyewale, Tajudeen O; Begum, Shahnaz; Uddin, Ziya; Tabassum, Shahina
2016-03-01
Serum-based rapid HIV testing algorithm in Bangladesh constitutes operational challenge to scaleup HIV testing and counselling (HTC) in the country. This study explored the operational feasibility of using whole blood as alternative to serum for rapid HIV testing in Bangladesh. Whole blood specimens were collected from two study groups. The groups included HIV-positive patients (n = 200) and HIV-negative individuals (n = 200) presenting at the reference laboratory in Dhaka, Bangladesh. The specimens were subjected to rapid HIV tests using the national algorithm with A1 = Alere Determine (United States), A2 = Uni-Gold (Ireland), and A3 = First Response (India). The sensitivity and specificity of the test results, and the operational cost were compared with current serum-based testing. The sensitivities [95% of confidence interval (CI)] for A1, A2, and A3 tests using whole blood were 100% (CI: 99.1-100%), 100% (CI: 99.1-100%), and 97% (CI: 96.4-98.2%), respectively, and specificities of all test kits were 100% (CI: 99.1-100%). Significant (P < 0.05) reduction in the cost of establishing HTC centre and consumables by 94 and 61%, respectively, were observed. The cost of administration and external quality assurance reduced by 39 and 43%, respectively. Overall, there was a 36% cost reduction in total operational cost of rapid HIV testing with blood when compared with serum. Considering the similar sensitivity and specificity of the two specimens, and significant cost reduction, rapid HIV testing with whole blood is feasible. A review of the national HIV rapid testing algorithm with whole blood will contribute toward improving HTC coverage in Bangladesh.
Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.
2001-01-01
To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995
75 FR 56051 - Bemidji to Grand Rapids Minnesota 230 kV Transmission Line Project
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-15
... Service Bemidji to Grand Rapids Minnesota 230 kV Transmission Line Project AGENCY: Rural Utilities Service... Environmental Impact Statement (EIS) for the proposed Bemidji to Grand Rapids, Minnesota 230 kV Transmission... Cooperative, Inc. for RUS financing to construct a 230 kilovolt (kV) transmission line between the Wilton...
Rapidly separating microneedles for transdermal drug delivery.
Zhu, Dan Dan; Wang, Qi Lei; Liu, Xu Bo; Guo, Xin Dong
2016-09-01
The applications of polymer microneedles (MNs) into human skin emerged as an alternative of the conventional hypodermic needles. However, dissolving MNs require many minutes to be dissolved in the skin and typically have difficulty being fully inserted into the skin, which may lead to the low drug delivery efficiency. To address these issues, we introduce rapidly separating MNs that can rapidly deliver drugs into the skin in a minimally invasive way. For the rapidly separating MNs, drug loaded dissolving MNs are mounted on the top of solid MNs, which are made of biodegradable polylactic acid which eliminate the biohazardous waste. These MNs have sufficient mechanical strength to be inserted into the skin with the drug loaded tips fully embedded for subsequent dissolution. Compared with the traditional MNs, rapidly separating MNs achieve over 90% of drug delivery efficiency in 30s while the traditional MNs needs 2min to achieve the same efficiency. With the in vivo test in mice, the micro-holes caused by rapidly separating MNs can heal in 1h, indicating that the rapidly separating MNs are safe for future applications. These results indicate that the design of rapidly separating dissolvable MNs can offer a quick, high efficient, convenient, safe and potentially self-administered method of drug delivery. Polymer microneedles offer an attractive, painless and minimally invasive approach for transdermal drug delivery. However, dissolving microneedles require many minutes to be dissolved in the skin and typically have difficulty being fully inserted into the skin due to the skin deformation, which may lead to the low drug delivery efficiency. In this work we proposed rapidly separating microneedles which can deliver over 90% of drug into the skin in 30s. The in vitro and in vivo results indicate that the new design of these microneedles can offer a quick, high efficient, convenient and safe method for transdermal drug delivery. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Guo, Lingling; Song, Shanshan; Liu, Liqiang; Peng, Juan; Kuang, Hua; Xu, Chuanlai
2015-09-01
Rapid and sensitive indirect competitive enzyme-linked immunosorbent assays (ic-ELISA) and gold nanoparticle immunochromatographic strip tests were developed to detect thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in milk and honey samples. The generic monoclonal antibody for TAP, FF and CAP was prepared based on a hapten [D-threo-1-(4-aminophenyl)-2- dichloroacetylamino-1,3-propanediol], and the haptenwas linked to a carrier protein using the diazotization method. After the optimization of several parameters (coating, pH, sodium chloride content and methanol content), the ic-ELISA was established. The quantitative working range for TAP was 0.11-1.36 ng/mL, with an IC50 of 0.39 ng/mL. The optimized ELISA showed cross-reactivity to CAP (300%) and FF (15.6%), with IC50 values of 0.13 and 2.5 ng/mL, respectively. The analytical recovery of TAP, FF and CAP in milk and honey samples in the ic-ELISA ranged from 81.2 to 112.9%. Based on this monoclonal antibody, a rapid and sensitive immunochromatographic test strip was also developed. This strip had a detection limit of 1 ng/mL for TAP, FF and CAP in milk and honey samples. Moreover, the test was completed within 10 min. Our results showed that the proposed ic-ELISA and immunochromatographic test strip method are highly useful screening tools for TAP, FF and CAP detection in milk and honey samples. Copyright © 2015 John Wiley & Sons, Ltd.
Rapid impact testing for quantitative assessment of large populations of bridges
NASA Astrophysics Data System (ADS)
Zhou, Yun; Prader, John; DeVitis, John; Deal, Adrienne; Zhang, Jian; Moon, Franklin; Aktan, A. Emin
2011-04-01
Although the widely acknowledged shortcomings of visual inspection have fueled significant advances in the areas of non-destructive evaluation and structural health monitoring (SHM) over the last several decades, the actual practice of bridge assessment has remained largely unchanged. The authors believe the lack of adoption, especially of SHM technologies, is related to the 'single structure' scenarios that drive most research. To overcome this, the authors have developed a concept for a rapid single-input, multiple-output (SIMO) impact testing device that will be capable of capturing modal parameters and estimating flexibility/deflection basins of common highway bridges during routine inspections. The device is composed of a trailer-mounted impact source (capable of delivering a 50 kip impact) and retractable sensor arms, and will be controlled by an automated data acquisition, processing and modal parameter estimation software. The research presented in this paper covers (a) the theoretical basis for SISO, SIMO and MIMO impact testing to estimate flexibility, (b) proof of concept numerical studies using a finite element model, and (c) a pilot implementation on an operating highway bridge. Results indicate that the proposed approach can estimate modal flexibility within a few percent of static flexibility; however, the estimated modal flexibility matrix is only reliable for the substructures associated with the various SIMO tests. To overcome this shortcoming, a modal 'stitching' approach for substructure integration to estimate the full Eigen vector matrix is developed, and preliminary results of these methods are also presented.
Stauffer, William M.; Cartwright, Charles P.; Olson, Douglas; Juni, Billie Anne; Taylor, Charlotte M; Bowers, Susan H.; Hanson, Kevan L.; Rosenblatt, Jon E.; Boulware, David R.
2010-01-01
Background Approximately 4 million U.S. travelers to developing countries are ill enough to seek healthcare with 1,500 malaria cases reported in the U.S. annually. The diagnosis of malaria is frequently delayed due to the time to prepare malaria blood films and lack of technical expertise. An easy, reliable rapid diagnostic test (RDT) with high sensitivity and negative predictive value (NPV), particularly for Plasmodium falciparum, would be clinically useful. The study objective was to determine the diagnostic performance of the FDA-approved NOW® Malaria Test in comparison to traditional thick and thin blood smears for malaria diagnosis. Methods This prospective study tested 852 consecutive blood samples sent for thick and thin smears with blinded, malaria rapid tests at three hospital laboratories during 2003–2006. Polymerase chain reaction (PCR) verified positive tests and discordant results. Results Malaria occurred in 11% (95/852). The rapid test had superior performance than the standard Giemsa thick blood smear (P=.003). The rapid test’s sensitivity for all malaria was 97% (92/95) vs. 85% (81/95) by blood smear, and the RDT had superior NPV of 99.6% vs. 98.2% (P=.001). The P. falciparum performance was excellent with 100% rapid test sensitivity versus only 88% (65/74) by blood smear (P=.003). Conclusions This operational study demonstrates the FDA-approved rapid malaria test is superior to a single set of blood smears performed under routine U.S. clinical laboratory conditions. The most valuable clinical role of the RDT is in the rapid diagnosis or the exclusion of P. falciparum malaria, which is particularly useful in outpatient settings when evaluating febrile travelers. PMID:19686072
Evaluation of a rapid immunodiagnostic test kit for rabies virus.
Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub
2007-10-01
A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).
Yorozu, Ayanori; Moriguchi, Toshiki; Takahashi, Masaki
2015-09-04
Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull-Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).
Code of Federal Regulations, 2014 CFR
2014-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
Code of Federal Regulations, 2013 CFR
2013-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
Vola, Ambra; Tamarozzi, Francesca; Noordin, Rahmah; Yunus, Muhammad Hafiznur; Khanbabaie, Sam; De Silvestri, Annalisa; Brunetti, Enrico; Mariconti, Mara
2018-04-14
Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases. Copyright © 2018 Elsevier Inc. All rights reserved.
Reyburn, Hugh; Mbakilwa, Hilda; Mwangi, Rose; Mwerinde, Ombeni; Olomi, Raimos; Drakeley, Chris; Whitty, Christopher J M
2007-02-24
To compare rapid diagnostic tests (RDTs) for malaria with routine microscopy in guiding treatment decisions for febrile patients. Randomised trial. Outpatient departments in northeast Tanzania at varying levels of malaria transmission. 2416 patients for whom a malaria test was requested. Staff received training on rapid diagnostic tests; patients sent for malaria tests were randomised to rapid diagnostic test or routine microscopy Proportion of patients with a negative test prescribed an antimalarial drug. Of 7589 outpatient consultations, 2425 (32%) had a malaria test requested. Of 1204 patients randomised to microscopy, 1030 (86%) tested negative for malaria; 523 (51%) of these were treated with an antimalarial drug. Of 1193 patients randomised to rapid diagnostic test, 1005 (84%) tested negative; 540 (54%) of these were treated for malaria (odds ratio 1.13, 95% confidence interval 0.95 to 1.34; P=0.18). Children aged under 5 with negative rapid diagnostic tests were more likely to be prescribed an antimalarial drug than were those with negative slides (P=0.003). Patients with a negative test by any method were more likely to be prescribed an antibiotic (odds ratio 6.42, 4.72 to 8.75; P<0.001). More than 90% of prescriptions for antimalarial drugs in low-moderate transmission settings were for patients for whom a test requested by a clinician was negative for malaria. Although many cases of malaria are missed outside the formal sector, within it malaria is massively over-diagnosed. This threatens the sustainability of deployment of artemisinin combination treatment, and treatable bacterial diseases are likely to be missed. Use of rapid diagnostic tests, with basic training for clinical staff, did not in itself lead to any reduction in over-treatment for malaria. Interventions to improve clinicians' management of febrile illness are essential but will not be easy. Clinical trials NCT00146796 [ClinicalTrials.gov].
Brown-Elliott, Barbara A.; Wallace, Richard J.
2002-01-01
The history, taxonomy, geographic distribution, clinical disease, and therapy of the pathogenic nonpigmented or late-pigmenting rapidly growing mycobacteria (RGM) are reviewed. Community-acquired disease and health care-associated disease are highlighted for each species. The latter grouping includes health care-associated outbreaks and pseudo-outbreaks as well as sporadic disease cases. Treatment recommendations for each species and type of disease are also described. Special emphasis is on the Mycobacterium fortuitum group, including M. fortuitum, M. peregrinum, and the unnamed third biovariant complex with its recent taxonomic changes and newly recognized species (including M. septicum, M. mageritense, and proposed species M. houstonense and M. bonickei). The clinical and taxonomic status of M. chelonae, M. abscessus, and M. mucogenicum is also detailed, along with that of the closely related new species, M. immunogenum. Additionally, newly recognized species, M. wolinskyi and M. goodii, as well as M. smegmatis sensu stricto, are included in a discussion of the M. smegmatis group. Laboratory diagnosis of RGM using phenotypic methods such as biochemical testing and high-performance liquid chromatography and molecular methods of diagnosis are also discussed. The latter includes PCR-restriction fragment length polymorphism analysis, hybridization, ribotyping, and sequence analysis. Susceptibility testing and antibiotic susceptibility patterns of the RGM are also annotated, along with the current recommendations from the National Committee for Clinical Laboratory Standards (NCCLS) for mycobacterial susceptibility testing. PMID:12364376
Brown-Elliott, Barbara A; Wallace, Richard J
2002-10-01
The history, taxonomy, geographic distribution, clinical disease, and therapy of the pathogenic nonpigmented or late-pigmenting rapidly growing mycobacteria (RGM) are reviewed. Community-acquired disease and health care-associated disease are highlighted for each species. The latter grouping includes health care-associated outbreaks and pseudo-outbreaks as well as sporadic disease cases. Treatment recommendations for each species and type of disease are also described. Special emphasis is on the Mycobacterium fortuitum group, including M. fortuitum, M. peregrinum, and the unnamed third biovariant complex with its recent taxonomic changes and newly recognized species (including M. septicum, M. mageritense, and proposed species M. houstonense and M. bonickei). The clinical and taxonomic status of M. chelonae, M. abscessus, and M. mucogenicum is also detailed, along with that of the closely related new species, M. immunogenum. Additionally, newly recognized species, M. wolinskyi and M. goodii, as well as M. smegmatis sensu stricto, are included in a discussion of the M. smegmatis group. Laboratory diagnosis of RGM using phenotypic methods such as biochemical testing and high-performance liquid chromatography and molecular methods of diagnosis are also discussed. The latter includes PCR-restriction fragment length polymorphism analysis, hybridization, ribotyping, and sequence analysis. Susceptibility testing and antibiotic susceptibility patterns of the RGM are also annotated, along with the current recommendations from the National Committee for Clinical Laboratory Standards (NCCLS) for mycobacterial susceptibility testing.
NASA Technical Reports Server (NTRS)
Wiegmann, Bruce M.
2017-01-01
The Heliopause Electrostatic Rapid Transit System (HERTS) was one of the seven total Phase II NASA Innovative Advanced Concepts (NIAC) that was down-selected in 2015 for continued funding and research. In Phase I our team learned that a spacecraft propelled by an Electric Sail (E-Sail) can travel great astronomical distances, such as to the Heliopause region of the solar system (approx. 100 to 120 AU) in approximately one quarter of the time (10 years) versus the time it took the Voyager spacecraft launched in 1977 (36 years). The completed work within the Phase II NIAC funded effort builds upon the work that was done in the Phase I NIAC and is focused on: 1) Testing of plasma interaction with a charged wire in a MSFC simulated solar environment vacuum test chamber. 2) Development of a Particle-in-Cell (PIC) models that are validated in the plasma testing and used to extrapolate to the E-Sail propulsion system design. 3) Conceptual design of a Technology Demonstration Mission (TDM) spacecraft developed to showcase E-Sail propulsion systems. 4) Down selection of both: a) Materials for a multi km length conductor and, b) Best configuration of the proposed conductor deployment subsystem. This paper will document the findings to date (June, 2017) of the above focused areas.
A proposed model membrane and test method for microneedle insertion studies.
Larrañeta, Eneko; Moore, Jessica; Vicente-Pérez, Eva M; González-Vázquez, Patricia; Lutton, Rebecca; Woolfson, A David; Donnelly, Ryan F
2014-09-10
A commercial polymeric film (Parafilm M(®), a blend of a hydrocarbon wax and a polyolefin) was evaluated as a model membrane for microneedle (MN) insertion studies. Polymeric MN arrays were inserted into Parafilm M(®) (PF) and also into excised neonatal porcine skin. Parafilm M(®) was folded before the insertions to closely approximate thickness of the excised skin. Insertion depths were evaluated using optical coherence tomography (OCT) using either a force applied by a Texture Analyser or by a group of human volunteers. The obtained insertion depths were, in general, slightly lower, especially for higher forces, for PF than for skin. However, this difference was not a large, being less than the 10% of the needle length. Therefore, all these data indicate that this model membrane could be a good alternative to biological tissue for MN insertion studies. As an alternative method to OCT, light microscopy was used to evaluate the insertion depths of MN in the model membrane. This provided a rapid, simple method to compare different MN formulations. The use of Parafilm M(®), in conjunction with a standardised force/time profile applied by a Texture Analyser, could provide the basis for a rapid MN quality control test suitable for in-process use. It could also be used as a comparative test of insertion efficiency between candidate MN formulations. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Janda, J Michael
2016-10-01
A key aspect of medical, public health, and diagnostic microbiology laboratories is the accurate and rapid reporting and communication regarding infectious agents of clinical significance. Microbial taxonomy in the age of molecular diagnostics and phylogenetics creates changes in taxonomy at a rapid rate further complicating this process. This update focuses on the description of new species and classification changes proposed in 2015. Copyright © 2016 Elsevier Inc. All rights reserved.
Flores Mateo, Gemma; Conejero, Jaume; Grenzner Martinel, Elisabet; Baba, Zeki; Dicono, Susana; Echasabal, Mildrey; Gonzalo Santos, Concepción; Aliaga, Arantxa; Barredo, María; Ruiz, Luis; Carrau, Montserrat
2010-07-01
To determine the validity of the rapid antigen test for the diagnoses of acute pharyngitis caused by group A beta-haemolytic Streptococcus (GABHS) compared with culture. Observational study of a consecutive sample of paediatric patients. Two primary care centres (PCC) from the metropolitan area of Barcelona. Children aged 1-14 years with sore throat of no more than 5 days duration were chosen at PCC. Oropharyngeal samples were collected from tonsillar bed and posterior pharynx. A rapid diagnostic test was performed, as well as a throat culture. A total of 211 patients were studied. The overall prevalence of pharyngitis due to Streptococcus was 34.1%. Compared with the throat culture, the sensitivity of the rapid test was 90.3% (95% CI: 81.0-96.0), the specificity was 78.4% (95% CI: 70.6-84.9). The percentage of false negatives was 9.7% and the false positives was 21.6%. Spectrum bias was present, inasmuch as the rapid test sensitivity increased with Centor scores. The diagnostic value of a rapid antigen test for the diagnosis of streptococcal pharyngitis in paediatric patients at PCC is high. However, the percentage of false positives and negatives is too high, and also the sensitivity is too low in patients with fewer symptoms to support the use of rapid antigenic test without culture confirmation and bacterial sensitivity test. 2009 Elsevier España, S.L. All rights reserved.
Flexible $$I_{Q}\\!\\!-\\!\\!V$$ Scheme of a DFIG for Rapid Voltage Regulation of a Wind Power Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinho; Muljadi, Eduard; Park, Jung -Wook
This paper proposes a flexible reactive current-to-voltage (I Q-V) scheme of a doubly-fed induction generator (DFIG) for the rapid voltage regulation of a wind power plant (WPP). In the proposed scheme, the WPP controller dispatches different voltage set points to the DFIGs depending on their rotor voltage margins. The DFIGs inject different reactive power with the flexible I Q-V schemes implemented in the rotor-side and grid-side converters. The I Q-V characteristic, which consists of the gain and width of a linear band and I Q capability, varies with time depending on the I Q capability of the converters and amore » voltage dip at the point of interconnection (POI). To increase the I Q capability during a fault, the active current is reduced in proportion to a voltage dip. If the I Q capability and/or the POI voltage dip are large, the I Q-V gain is set to be high, thereby providing rapid voltage regulation. To avoid an overvoltage after the fault clearance, a rapid I Q reduction scheme is implemented in the WPP and DFIG controllers. The performance of the proposed flexible scheme was verified under scenarios with various disturbances. In conclusion, the proposed scheme can help increase wind power penetration without jeopardizing voltage stability.« less
Flexible $$I_{Q}\\!\\!-\\!\\!V$$ Scheme of a DFIG for Rapid Voltage Regulation of a Wind Power Plant
Kim, Jinho; Muljadi, Eduard; Park, Jung -Wook; ...
2017-04-28
This paper proposes a flexible reactive current-to-voltage (I Q-V) scheme of a doubly-fed induction generator (DFIG) for the rapid voltage regulation of a wind power plant (WPP). In the proposed scheme, the WPP controller dispatches different voltage set points to the DFIGs depending on their rotor voltage margins. The DFIGs inject different reactive power with the flexible I Q-V schemes implemented in the rotor-side and grid-side converters. The I Q-V characteristic, which consists of the gain and width of a linear band and I Q capability, varies with time depending on the I Q capability of the converters and amore » voltage dip at the point of interconnection (POI). To increase the I Q capability during a fault, the active current is reduced in proportion to a voltage dip. If the I Q capability and/or the POI voltage dip are large, the I Q-V gain is set to be high, thereby providing rapid voltage regulation. To avoid an overvoltage after the fault clearance, a rapid I Q reduction scheme is implemented in the WPP and DFIG controllers. The performance of the proposed flexible scheme was verified under scenarios with various disturbances. In conclusion, the proposed scheme can help increase wind power penetration without jeopardizing voltage stability.« less
Dynamic Modeling, Controls, and Testing for Electrified Aircraft
NASA Technical Reports Server (NTRS)
Connolly, Joseph; Stalcup, Erik
2017-01-01
Electrified aircraft have the potential to provide significant benefits for efficiency and emissions reductions. To assess these potential benefits, modeling tools are needed to provide rapid evaluation of diverse concepts and to ensure safe operability and peak performance over the mission. The modeling challenge for these vehicles is the ability to show significant benefits over the current highly refined aircraft systems. The STARC-ABL (single-aisle turbo-electric aircraft with an aft boundary layer propulsor) is a new test proposal that builds upon previous N3-X team hybrid designs. This presentation describes the STARC-ABL concept, the NASA Electric Aircraft Testbed (NEAT) which will allow testing of the STARC-ABL powertrain, and the related modeling and simulation efforts to date. Modeling and simulation includes a turbofan simulation, Numeric Propulsion System Simulation (NPSS), which has been integrated with NEAT; and a power systems and control model for predicting testbed performance and evaluating control schemes. Model predictions provide good comparisons with testbed data for an NPSS-integrated test of the single-string configuration of NEAT.
Barış, Ayşe; Anlıaçık, Nur; Bulut, Mehmet Emin; Deniz, Rıdvan; Yücel, Elif; Aktaş, Elif
2017-01-01
Pharyngitis in most cases is due to viral microorganisms however drug therapy without the detection of etiological agent leads to unnecessary use of antibiotics. On the other hand, when the etiologic agent is group A beta-hemolytic streptococci (GAS) it is important to identify the etiologic agent rapidly which will guide the treatment with appropriate antibiotics. The use of highly sensitive rapid tests will contribute significantly to early diagnosis and appropriate therapy. The aim of this study is to evaluate the efficacy of Mascia Brunelli rapid antigen test for the detection of GAS in throat swab samples. A total of 833 throat swab samples submitted to our laboratory with pre-diagnosis of pharyngitis were assessed between June 2016 and August 2016. The samples were simultaneously cultured and tested by rapid Mascia Brunelli Strep-A Card (Mascia Brunelli S.p.a, Italy). For identification, bacitracin sensitivity, PYR test and latex agglutination test in addition to Bruker MALDI-TOF MS (Daltonics, Germany) system were used. The density of GAS growth in the culture was noted. The samples that were false negative with Mascia Brunelli test were re-tested with QuickVue + Strep A Test (Quidel Corporation, San Diego, USA) rapid antigen test. A total of 833 patients, 376 (45.2%) female and 457 (54.8%) male were included in the study. The age range was between 0-94 years with a mean value of 7.86 ± 6.72. 125 (15%) and 94 (11.28%) of the samples were positive with culture and rapid antigen test, respectively. Mascia Brunelli antigen test gave negative results for 31 culture positive samples. Of these 31 samples, 28 were found positive by QuickVue + Strep A antigen test. As a result, the sensitivity of the test was found to be independent of the inoculum effect. The culture positivity rate in patients between 5-15 years was 18.4%. The sensitivity, specificity, positive predictive value, negative predictive value and the accuracy of Mascia Brunelli antigen test, with respect to culture, were 75.2%, 100%, 100%, 95.81% and 96.28%, respectively. In conclusion, the selection of rapid antigen tests with high sensitivity in the diagnosis of GAS pharyngitis will contribute to the prevention of resistance development by appropriate use of antibiotics as well as early diagnosis and appropriate treatment. However, confirmation of negative rapid antigen test results by culture is very important in terms of false diagnosis and prevention of incomplete treatment.
Rapid determination of Faraday rotation in optical glasses by means of secondary Faraday modulator.
Sofronie, M; Elisa, M; Sava, B A; Boroica, L; Valeanu, M; Kuncser, V
2015-05-01
A rapid high sensitive method for determining the Faraday rotation of optical glasses is proposed. Starting from an experimental setup based on a Faraday rod coupled to a lock-in amplifier in the detection chain, two methodologies were developed for providing reliable results on samples presenting low and large Faraday rotations. The proposed methodologies were critically discussed and compared, via results obtained in transmission geometry, on a new series of aluminophosphate glasses with or without rare-earth doping ions. An example on how the method can be used for a rapid examination of the optical homogeneity of the sample with respect to magneto-optical effects is also provided.
CUQI: cardiac ultrasound video quality index
Razaak, Manzoor; Martini, Maria G.
2016-01-01
Abstract. Medical images and videos are now increasingly part of modern telecommunication applications, including telemedicinal applications, favored by advancements in video compression and communication technologies. Medical video quality evaluation is essential for modern applications since compression and transmission processes often compromise the video quality. Several state-of-the-art video quality metrics used for quality evaluation assess the perceptual quality of the video. For a medical video, assessing quality in terms of “diagnostic” value rather than “perceptual” quality is more important. We present a diagnostic-quality–oriented video quality metric for quality evaluation of cardiac ultrasound videos. Cardiac ultrasound videos are characterized by rapid repetitive cardiac motions and distinct structural information characteristics that are explored by the proposed metric. Cardiac ultrasound video quality index, the proposed metric, is a full reference metric and uses the motion and edge information of the cardiac ultrasound video to evaluate the video quality. The metric was evaluated for its performance in approximating the quality of cardiac ultrasound videos by testing its correlation with the subjective scores of medical experts. The results of our tests showed that the metric has high correlation with medical expert opinions and in several cases outperforms the state-of-the-art video quality metrics considered in our tests. PMID:27014715
Screening for acute HIV infection in South Africa: finding acute and chronic disease
Bassett, Ingrid V.; Chetty, Senica; Giddy, Janet; Reddy, Shabashini; Bishop, Karen; Lu, Zhigang; Losina, Elena; Freedberg, Kenneth A.; Walensky, Rochelle P.
2010-01-01
Background The yield of screening for acute HIV infection among general medical patients in resource-scarce settings remains unclear. Our objective was to evaluate a strategy of pooled HIV plasma RNA to diagnose acute HIV infection in patients with negative or discordant rapid HIV antibody tests in Durban, South Africa. Methods We prospectively enrolled patients with negative or discordant rapid HIV antibody tests from a routine HIV screening program in an outpatient department in Durban with an HIV prevalence of 48%. Study participants underwent venipuncture for pooled qualitative HIV RNA, and if positive, quantitative RNA, enzyme immunoassay and Western Blot (WB). Patients with negative or indeterminate WB and positive quantitative HIV RNA were considered acutely infected. Those with chronic infection (positive RNA and WB) despite negative or discordant rapid HIV tests were considered false negative rapid antibody tests. Results Nine hundred ninety-four participants were enrolled with either negative (N=976) or discordant (N=18) rapid test results. Eleven (1.1%, 95% CI: 0.6–2.0%) had acute HIV infection. Of the 994 patients, an additional 20 (2.0%, 95% CI: 1.3–.3.1%) had chronic HIV infection (false negative rapid test). Conclusions One percent of outpatients with negative or discordant rapid HIV tests in Durban, South Africa had acute HIV infection readily detectable through pooled serum HIV RNA screening. Pooled RNA testing also identified an additional 2% of patients with chronic HIV infection. HIV RNA screening has the potential to identify both acute and chronic HIV infections that are otherwise missed by standard HIV testing algorithms. PMID:20553336
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-02
... Grand Rapids 230 kV Transmission Line Project AGENCY: Rural Utilities Service, USDA. ACTION: Notice of... proposed Bemidji to Grand Rapids 230 kV Transmission Line Project (Project) in Beltrami, Hubbard, Itasca... financing to construct the 230 kilovolt (kV) transmission line between the Wilton Substation near Bemidji...
A seamless acquisition digital storage oscilloscope with three-dimensional waveform display
NASA Astrophysics Data System (ADS)
Yang, Kuojun; Tian, Shulin; Zeng, Hao; Qiu, Lei; Guo, Lianping
2014-04-01
In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.
A seamless acquisition digital storage oscilloscope with three-dimensional waveform display
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Kuojun, E-mail: kuojunyang@gmail.com; Guo, Lianping; School of Electrical and Electronic Engineering, Nanyang Technological University
In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, whichmore » converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.« less
False positive malaria rapid diagnostic test in returning traveler with typhoid fever.
Meatherall, Bonnie; Preston, Keith; Pillai, Dylan R
2014-07-09
Rapid diagnostic tests play a pivotal role in the early diagnosis of malaria where microscopy or polymerase chain reaction are not immediately available. We report the case of a 39 year old traveler to Canada who presented with fever, headache, and abdominal pain after visiting friends and relatives in India. While in India, the individual was not ill and had no signs or symptoms of malaria. Laboratory testing upon his return to Canada identified a false positive malaria rapid diagnostic (BinaxNOW® malaria) result for P. falciparum with coincident Salmonella Typhi bacteraemia without rheumatoid or autoimmune factors. Rapid diagnostic test false positivity for malaria coincided with the presence or absence of Salmonella Typhi in the blood. Clinicians should be aware that Salmonella Typhi infection may result in a false positive malaria rapid diagnostic test. The mechanism of this cross-reactivity is not clear.
Wang, Jane X; Cohen, Neal J; Voss, Joel L
2015-01-01
Effective choices generally require memory, yet little is known regarding the cognitive or neural mechanisms that allow memory to influence choices. We outline a new framework proposing that covert memory processing of hippocampus interacts with action-generation processing of prefrontal cortex in order to arrive at optimal, memory-guided choices. Covert, rapid action-memory simulation (CRAMS) is proposed here as a framework for understanding cognitive and/or behavioral choices, whereby prefrontal-hippocampal interactions quickly provide multiple simulations of potential outcomes used to evaluate the set of possible choices. We hypothesize that this CRAMS process is automatic, obligatory, and covert, meaning that many cycles of action-memory simulation occur in response to choice conflict without an individual's necessary intention and generally without awareness of the simulations, leading to adaptive behavior with little perceived effort. CRAMS is thus distinct from influential proposals that adaptive memory-based behavior in humans requires consciously experienced memory-based construction of possible future scenarios and deliberate decisions among possible future constructions. CRAMS provides an account of why hippocampus has been shown to make critical contributions to the short-term control of behavior, and it motivates several new experimental approaches and hypotheses that could be used to better understand the ubiquitous role of prefrontal-hippocampal interactions in situations that require adaptively using memory to guide choices. Importantly, this framework provides a perspective that allows for testing decision-making mechanisms in a manner that translates well across human and nonhuman animal model systems. Copyright © 2014 Elsevier Inc. All rights reserved.
A fast and simple label-free immunoassay based on a smartphone.
Giavazzi, Fabio; Salina, Matteo; Ceccarello, Erica; Ilacqua, Andrea; Damin, Francesco; Sola, Laura; Chiari, Marcella; Chini, Bice; Cerbino, Roberto; Bellini, Tommaso; Buscaglia, Marco
2014-08-15
Despite the continuous advancements in bio-molecular detection and fluidic systems integration, the realization of portable and high performance devices for diagnostic applications still presents major difficulties, mostly because of the need to combine adequate sensitivity with low cost of production and operational simplicity and speed. In this context, we propose a compact device composed of a smartphone and a custom-designed cradle, containing only a disposable sensing cartridge, a tiny magnetic stirrer and a few passive optical components. The detection principle is the previously proposed Reflective Phantom Interface that is based on measuring the intensity of light reflected by the surface of an amorphous fluoropolymer substrate, which has a refractive index very close to that of the aqueous sample solution and hosts various antibodies immobilized within spots. The reflectivity of dozens of spots is monitored in real time by the phone׳s camera using the embedded flash LED as the illumination source. We test the performance of the combined device targeting heterologous immunoglobulins and antigens commonly used as markers for diagnoses of hepatitis B and HIV. Target concentrations as low as a few ng/ml can be rapidly and robustly determined by comparing the rate of increase of the signal after the addition of the sample with that measured after the subsequent addition of a standard solution with known concentration. The features of the proposed system enable the realization of novel handheld biosensing devices suitable for those applications where multiple targets have to be rapidly detected even without the presence of trained personnel. Copyright © 2014 Elsevier B.V. All rights reserved.
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-11-01
Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman's correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India.
Anitharaj, Velmurugan; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-01-01
Introduction Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Aim Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. Materials and Methods This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman’s correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Results Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. Conclusion This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India. PMID:28050364
Rapid tests for diagnosis of leptospirosis: current tools and emerging technologies.
Picardeau, Mathieu; Bertherat, Eric; Jancloes, Michel; Skouloudis, Andreas N; Durski, Kara; Hartskeerl, Rudy A
2014-01-01
Leptospirosis is an emerging zoonosis with a worldwide distribution but is more commonly found in impoverished populations in developing countries and tropical regions with frequent flooding. The rapid detection of leptospirosis is a critical step to effectively manage the disease and to control outbreaks in both human and animal populations. Therefore, there is a need for accurate and rapid diagnostic tests and appropriate surveillance and alert systems to identify outbreaks. This review describes current in-house methods and commercialized tests for the rapid diagnosis of acute leptospirosis. It focuses on diagnostic tests that can be performed with minimal training and limited equipment in less-developed and newly industrialized countries, particularly in resource-limited settings and with results in minutes to less than 4 hours. We also describe recent technological advances in the field of diagnostic tests that could allow for the development of innovative rapid tests in the near future. © 2013 Elsevier Inc. All rights reserved.
Validation of the Puumala virus rapid field test for bank voles in Germany.
Reil, D; Imholt, C; Rosenfeld, U M; Drewes, S; Fischer, S; Heuser, E; Petraityte-Burneikiene, R; Ulrich, R G; Jacob, J
2017-02-01
Puumala virus (PUUV) causes many human infections in large parts of Europe and can lead to mild to moderate disease. The bank vole (Myodes glareolus) is the only reservoir of PUUV in Central Europe. A commercial PUUV rapid field test for rodents was validated for bank-vole blood samples collected in two PUUV-endemic regions in Germany (North Rhine-Westphalia and Baden-Württemberg). A comparison of the results of the rapid field test and standard ELISAs indicated a test efficacy of 93-95%, largely independent of the origin of the antigens used in the ELISA. In ELISAs, reactivity for the German PUUV strain was higher compared to the Swedish strain but not compared to the Finnish strain, which was used for the rapid field test. In conclusion, the use of the rapid field test can facilitate short-term estimation of PUUV seroprevalence in bank-vole populations in Germany and can aid in assessing human PUUV infection risk.
Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen
2004-10-01
Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.
Bie, Zhenying; Lu, Wei; Zhu, You; Chen, Yusong; Ren, Hubo; Ji, Lishun
2017-01-27
A fully automated, rapid, and reliable method for simultaneous determination of six carcinogenic primary aromatic amines (AAs), including o-toluidine (o-TOL), 2, 6-dimethylaniline (2, 6-DMA), o-anisidine (o-ASD), 1-naphthylamine (1-ANP), 2-naphthylamine (2-ANP), and 4-aminobiphenyl (4-ABP), in mainstream cigarette smoke was established. The proposed method was based on two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry (SPE/LC-MS/MS). The particulate phase of the mainstream cigarette smoke was collected on a Cambridge filter pad and pretreated via ultrasonic extraction with 2% formic acid (FA), while the gas phase was trapped by 2% FA without pretreatment for determination. The two-dimensional online SPE comprised of two cartridges with different absorption characteristics was applied for sample pretreatment. Analysis was performed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) under multiple reaction monitoring mode. Each sample required about 0.5h for solid phase extraction and analysis. The limit of detections (LODs) for six AAs ranged from 0.04 to 0.58ng/cig and recoveries were within 84.5%-122.9%. The relative standard deviations of intra- and inter-day tests for 3R4F reference cigarette were less than 6% and 7%, respectively, while no more than 7% and 8% separately for a type of Virginia cigarette. The proposed method enabled minimum sample pretreatment, full automation, and high throughput with high selectivity, sensitivity, and accuracy. As a part of the validation procedure, fifteen brands of cigarettes were tested by the designed method. Copyright © 2016 Elsevier B.V. All rights reserved.
Ramírez-Barahona, Santiago; Barrera-Redondo, Josué; Eguiarte, Luis E.
2016-01-01
Variation in species richness across regions and between different groups of organisms is a major feature of evolution. Several factors have been proposed to explain these differences, including heterogeneity in the rates of species diversification and the age of clades. It has been frequently assumed that rapid rates of diversification are coupled to high rates of ecological and morphological evolution, leading to a prediction that remains poorly explored for most species: the positive association between ecological niche divergence, morphological evolution and species diversification. We combined a time-calibrated phylogeny with distribution, ecological and body size data for scaly tree ferns (Cyatheaceae) to test whether rates of species diversification are predicted by the rates at which clades have evolved distinct ecological niches and body sizes. We found that rates of species diversification are positively correlated with rates of ecological and morphological evolution, with rapidly diversifying clades also showing rapidly evolving ecological niches and body sizes. Our results show that rapid diversification of scaly tree ferns is associated with the evolution of species with comparable morphologies that diversified into similar, yet distinct, environments. This suggests parallel evolutionary pathways opening in different tropical regions whenever ecological and geographical opportunities arise. Accordingly, rates of ecological niche and body size evolution are relevant to explain the current patterns of species richness in this ‘ancient’ fern lineage across the tropics. PMID:27412279
Enhancing creative cognition with a rapid right-parietal neurofeedback procedure.
Agnoli, Sergio; Zanon, Marco; Mastria, Serena; Avenanti, Alessio; Corazza, Giovanni Emanuele
2018-02-14
The present article describes an innovative neurofeedback training (NFT) procedure aimed at increasing creative cognition through the enhancement of specific brain activities previously associated with divergent thinking. We designed and tested two NFT protocols based on training alpha and beta EEG oscillations selectively measured over the right parietal region. A total of 80 participants were involved, 40 in the alpha NFT protocol and 40 in the beta NFT protocol. The NFT loop was closed on a video stream that would advance only when oscillation power exceeded a normalized threshold. The total duration of the protocol was two hours in a single day, hence its classification as rapid. Changes in ideational fluency and originality, measured with a divergent thinking task, were compared between participants receiving real video feedback and participants receiving sham feedback. We controlled for individual differences in creative achievement level. Results showed that the protocols were effective at enhancing alpha and beta activities in the targeted area. Differences between the two protocols emerged in their effectiveness at promoting divergent thinking. While no significant changes in originality resulted from the rapid alpha NFT, increases in both originality and fluency emerged as a consequence of the rapid beta NFT. These results were particularly evident in participants starting with a low creative achievement level. Possible interpretations and future directions are proposed and discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ramírez-Barahona, Santiago; Barrera-Redondo, Josué; Eguiarte, Luis E
2016-07-13
Variation in species richness across regions and between different groups of organisms is a major feature of evolution. Several factors have been proposed to explain these differences, including heterogeneity in the rates of species diversification and the age of clades. It has been frequently assumed that rapid rates of diversification are coupled to high rates of ecological and morphological evolution, leading to a prediction that remains poorly explored for most species: the positive association between ecological niche divergence, morphological evolution and species diversification. We combined a time-calibrated phylogeny with distribution, ecological and body size data for scaly tree ferns (Cyatheaceae) to test whether rates of species diversification are predicted by the rates at which clades have evolved distinct ecological niches and body sizes. We found that rates of species diversification are positively correlated with rates of ecological and morphological evolution, with rapidly diversifying clades also showing rapidly evolving ecological niches and body sizes. Our results show that rapid diversification of scaly tree ferns is associated with the evolution of species with comparable morphologies that diversified into similar, yet distinct, environments. This suggests parallel evolutionary pathways opening in different tropical regions whenever ecological and geographical opportunities arise. Accordingly, rates of ecological niche and body size evolution are relevant to explain the current patterns of species richness in this 'ancient' fern lineage across the tropics. © 2016 The Author(s).
NASA Astrophysics Data System (ADS)
Bratchenko, Ivan A.; Artemyev, Dmitry N.; Myakinin, Oleg O.; Khristoforova, Yulia A.; Moryatov, Alexander A.; Kozlov, Sergey V.; Zakharov, Valery P.
2017-02-01
The differentiation of skin melanomas and basal cell carcinomas (BCCs) was demonstrated based on combined analysis of Raman and autofluorescence spectra stimulated by visible and NIR lasers. It was ex vivo tested on 39 melanomas and 40 BCCs. Six spectroscopic criteria utilizing information about alteration of melanin, porphyrins, flavins, lipids, and collagen content in tumor with a comparison to healthy skin were proposed. The measured correlation between the proposed criteria makes it possible to define weakly correlated criteria groups for discriminant analysis and principal components analysis application. It was shown that the accuracy of cancerous tissues classification reaches 97.3% for a combined 6-criteria multimodal algorithm, while the accuracy determined separately for each modality does not exceed 79%. The combined 6-D method is a rapid and reliable tool for malignant skin detection and classification.
Elaziz, Mohamed Abd; Hemdan, Ahmed Monem; Hassanien, AboulElla; Oliva, Diego; Xiong, Shengwu
2017-09-07
The current economics of the fish protein industry demand rapid, accurate and expressive prediction algorithms at every step of protein production especially with the challenge of global climate change. This help to predict and analyze functional and nutritional quality then consequently control food allergies in hyper allergic patients. As, it is quite expensive and time-consuming to know these concentrations by the lab experimental tests, especially to conduct large-scale projects. Therefore, this paper introduced a new intelligent algorithm using adaptive neuro-fuzzy inference system based on whale optimization algorithm. This algorithm is used to predict the concentration levels of bioactive amino acids in fish protein hydrolysates at different times during the year. The whale optimization algorithm is used to determine the optimal parameters in adaptive neuro-fuzzy inference system. The results of proposed algorithm are compared with others and it is indicated the higher performance of the proposed algorithm.
Sexual selection accelerates signal evolution during speciation in birds.
Seddon, Nathalie; Botero, Carlos A; Tobias, Joseph A; Dunn, Peter O; Macgregor, Hannah E A; Rubenstein, Dustin R; Uy, J Albert C; Weir, Jason T; Whittingham, Linda A; Safran, Rebecca J
2013-09-07
Sexual selection is proposed to be an important driver of diversification in animal systems, yet previous tests of this hypothesis have produced mixed results and the mechanisms involved remain unclear. Here, we use a novel phylogenetic approach to assess the influence of sexual selection on patterns of evolutionary change during 84 recent speciation events across 23 passerine bird families. We show that elevated levels of sexual selection are associated with more rapid phenotypic divergence between related lineages, and that this effect is restricted to male plumage traits proposed to function in mate choice and species recognition. Conversely, we found no evidence that sexual selection promoted divergence in female plumage traits, or in male traits related to foraging and locomotion. These results provide strong evidence that female choice and male-male competition are dominant mechanisms driving divergence during speciation in birds, potentially linking sexual selection to the accelerated evolution of pre-mating reproductive isolation.
NASA Technical Reports Server (NTRS)
Moore, Royce D.; Shyne, Rickey J.; Boldman, Donald R.; Gelder, Thomas F.
1987-01-01
Detailed flow surveys downstream of the corner turning vanes and downstream of the fan inlet guide vanes have been obtained in a 0.1-scale model of the NASA Lewis Research Center's proposed Altitude Wind Tunnel. Two turning vane designs were evaluated in both corners 1 and 2 (the corners between the test section and the drive fan). Vane A was a controlled-diffusion airfoil and vane B was a circular-arc airfoil. At given flows the turning vane wakes were surveyed to determine the vane pressure losses. For both corners the vane A turning vane configuration gave lower losses than the vane B configuration in the regions where the flow regime should be representative of two-dimensional flow. For both vane sets the vane loss coefficient increased rapidly near the walls.
Spectra library assisted de novo peptide sequencing for HCD and ETD spectra pairs.
Yan, Yan; Zhang, Kaizhong
2016-12-23
De novo peptide sequencing via tandem mass spectrometry (MS/MS) has been developed rapidly in recent years. With the use of spectra pairs from the same peptide under different fragmentation modes, performance of de novo sequencing is greatly improved. Currently, with large amount of spectra sequenced everyday, spectra libraries containing tens of thousands of annotated experimental MS/MS spectra become available. These libraries provide information of the spectra properties, thus have the potential to be used with de novo sequencing to improve its performance. In this study, an improved de novo sequencing method assisted with spectra library is proposed. It uses spectra libraries as training datasets and introduces significant scores of the features used in our previous de novo sequencing method for HCD and ETD spectra pairs. Two pairs of HCD and ETD spectral datasets were used to test the performance of the proposed method and our previous method. The results show that this proposed method achieves better sequencing accuracy with higher ranked correct sequences and less computational time. This paper proposed an advanced de novo sequencing method for HCD and ETD spectra pair and used information from spectra libraries and significant improved previous similar methods.
Dynamic interpretation of slug tests in highly permeable aquifers
Zurbuchen, Brian R.; Zlotnik, Vitaly A.; Butler, James J.
2002-01-01
Considerable progress has been made in developing a theoretical framework for modeling slug test responses in formations with high hydraulic conductivity K. However, several questions of practical significance remain unresolved. Given the rapid and often oscillatory nature of test responses, the traditional hydrostatic relationship between the water level and the transducer‐measured head in the water column may not be appropriate. A general dynamic interpretation is proposed that describes the relationship between water level response and transducer‐measured head. This theory is utilized to develop a procedure for transforming model‐generated water level responses to transducer readings. The magnitude of the difference between the actual water level position and the apparent position based on the transducer measurement is a function of the acceleration and velocity of the water column, test geometry, and depth of the transducer. The dynamic approach explains the entire slug test response, including the often‐noted discrepancy between the actual initial water level displacement and that measured by a transducer in the water column. Failure to use this approach can lead to a significant underestimation of K when the transducer is a considerable distance below the static water level. Previous investigators have noted a dependence of test responses on the magnitude of the initial water level displacement and have developed various approximate methods for analyzing such data. These methods are re‐examined and their limitations clarified. Practical field guidelines are proposed on the basis of findings of this work. The soundness of the dynamic approach is demonstrated through a comparison of K profiles from a series of multilevel slug tests with those from dipole‐flow tests performed in the same wells.
A novel one-step Helicobacter pylori saliva antigen test.
Yang, Bi-Ling; Yeh, Chun; Kwong, Wei-Gang; Lee, Shou-Dong
2015-02-01
A rapid, reliable, and sufficiently accurate test for diagnosing Helicobacter pylori infection is required for screening dyspeptic patients before a referral for endoscopy. The purpose of this article is two-fold: first, to evaluate the accuracy of a one-step H. pylori saliva antigen (HPS) test; and second, to compare noninvasive and invasive H. pylori tests in Taiwanese population. A total of 104 consecutive dyspeptic patients admitted for gastroenterology into the outpatient department underwent a one-step HPS test, rapid urease test, histology, and (13)C-urea breath test (13)C-UBT (proto C-13 urea kit). The accuracy of the HPS test was compared with a gold standard defined by at least two positive H. pylori test results from three H. pylori tests (histology, rapid urease test, and (13)C-UBT). The 104 patients eligible for analysis (mean age: 58 years, range 22-87 years), 21 (20%) were gold standard positive. Among them, the positive of the one-step H. pylori saliva Ag test, rapid urease test, (13)C-UBT, histology were (52; 50%), (17; 16%), (27; 25%) and (22; 21%) respectively. The sensitivity and specificity of the HPS tests, rapid urease test, (13)C-UBTs, and histology were 71.43% and 55.42%, 76.19% and 98.80%, 100% and 92.77%, and 85.71% and 95.18%, respectively, relative to the gold standard. The one-step HPS test exhibited a sensitivity of 71.43%, nearly equivalent to that of the rapid urea test. The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample), inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection. Copyright © 2014. Published by Elsevier Taiwan.
Shu, Pei-Yun; Yang, Cheng-Fen; Kao, Jeng-Fong; Su, Chien-Ling; Chang, Shu-Fen; Lin, Chien-Chou; Yang, Wen-Chih; Shih, Hsiu; Yang, Shih-Yan; Wu, Ping-Fuai; Wu, Ho-Sheng; Huang, Jyh-Hsiung
2009-04-01
We used the dengue virus NS1 antigen (Ag) rapid test for on-site detection of imported dengue cases at airports. Among 22 positive cases of dengue identified from 850 patients with a fever suspected to have dengue, 17 were NS1 Ag test positive. These findings demonstrate the usefulness of the NS1 Ag rapid test in screening imported dengue cases at airports.
Shu, Pei-Yun; Yang, Cheng-Fen; Kao, Jeng-Fong; Su, Chien-Ling; Chang, Shu-Fen; Lin, Chien-Chou; Yang, Wen-Chih; Shih, Hsiu; Yang, Shih-Yan; Wu, Ping-Fuai; Wu, Ho-Sheng; Huang, Jyh-Hsiung
2009-01-01
We used the dengue virus NS1 antigen (Ag) rapid test for on-site detection of imported dengue cases at airports. Among 22 positive cases of dengue identified from 850 patients with a fever suspected to have dengue, 17 were NS1 Ag test positive. These findings demonstrate the usefulness of the NS1 Ag rapid test in screening imported dengue cases at airports. PMID:19193828
[Assessment of a rapid diagnostic test for malaria in rural health care facilities in Senegal].
Munier, A; Diallo, A; Sokhna, C; Chippaux, J P
2009-10-01
The aim of the study was to determine the accuracy of a rapid diagnostic test in confirming presumptive malaria diagnosis in a rural zone of Senegal. Thick blood smear was used as the reference technique for comparison. METHOHDOLOGY: Testing was conducted on children between the ages of 1 and 14 years at three health care facilities located in the Niakhar are from August 2006 to June 2007. If malaria was suspected by the nurse based on clinical findings, two thick smears and one rapid diagnostic test (Core Malaria Pf) were performed. Blood slides were stained in Niakhar and read in Dakar. A total of 474 patients were examined. Three-fourths (75%) of these patients were seen during the rainy season. Malaria was suspected in 335 patients (71%). Rapid tests and thick smears were obtained in 330 of these patients with positive results in 194 (59%) and 180 (55%) respectively. The sensitivity, specificity, positive predictive value and negative predictive value of the rapid test were 96%, 87%, 90% and 95% respectively. Our data show that the rapid diagnostic test used in this study exhibits good sensitivity and positive predictive value. Despite its cost this test could be helpful in confirming malaria diagnosis in outlying health care facilities without the necessary resources to perform blood smears. Confirmation is necessary to avoid unwarranted prescription of malaria treatment due to inaccurate clinical diagnosis
May, Larissa S.; Rothman, Richard E.; Miller, Loren G.; Brooks, Gillian; Zocchi, Mark; Zatorski, Catherine; Dugas, Andrea F.; Ware, Chelsea E.; Jordan, Jeanne A.
2017-01-01
OBJECTIVE To determine whether real-time availability of rapid molecular results of Staphylococcus aureus would impact emergency department clinician antimicrobial selection for adults with cutaneous abscesses. DESIGN We performed a prospective, randomized controlled trial comparing a rapid molecular test with standard of care culture-based testing. Follow-up telephone calls were made at between 2 and 7 days, 1 month, and 3 months after discharge. SETTING Two urban, academic emergency departments. PATIENTS Patients at least 18 years old presenting with a chief complaint of abscess, cellulitis, or insect bite and receiving incision and drainage were eligible. Seven hundred seventy-eight people were assessed for eligibility and 252 met eligibility criteria. METHODS Clinician antibiotic selection and clinical outcomes were evaluated. An ad hoc outcome of test performance was performed. RESULTS We enrolled 252 patients and 126 were randomized to receive the rapid test. Methicillin-susceptible S. aureus–positive patients receiving rapid test results were prescribed beta-lactams more often than controls (absolute difference, 14.5% [95% CI, 1.1%–30.1%]) whereas methicillin-resistant S. aureus–positive patients receiving rapid test results were more often prescribed anti–methicillin-resistant S. aureus antibiotics (absolute difference, 21.5% [95% CI, 10.1%–33.0%]). There were no significant differences between the 2 groups in 1-week or 3-month clinical outcomes. CONCLUSION Availability of rapid molecular test results after incision and drainage was associated with more-targeted antibiotic selection. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01523899 PMID:26306996
A pilot study of rapid hepatitis C virus testing in the Rhode Island Department of Corrections.
Beckwith, Curt G; Kurth, Ann E; Bazerman, Lauri B; Patry, Emily J; Cates, Alice; Tran, Liem; Noska, Amanda; Kuo, Irene
2016-03-01
The correctional population bears a heavy burden of hepatitis C virus (HCV) infection necessitating expansion of HCV testing and treatment opportunities. Rapid HCV testing provides point-of-care antibody results and may be ideal for correctional facilities, particularly jails, where persons are often incarcerated for short periods of time, yet feasibility has not been established. We conducted a pilot study of a rapid HCV testing algorithm among short-term inmates with unknown HCV status. Participants completed a questionnaire, viewed an informational video and underwent rapid HCV testing and confirmatory testing, when indicated. Persons with chronic infection were referred to community care after release. Baseline characteristics, risk behaviors, test results and linkage were examined by descriptive analyses. Two hundred and fifty-two inmates were enrolled and 249 completed all study activities. Twenty-five participants (10%) had reactive rapid tests and 23 (92%) completed confirmatory testing. 15/23 (65%) had detectable HCV RNA, but only 4 linked to care after release. Persons with reactive HCV tests were more likely to be White (P = 0.01) and to have ever injected (P < 0.0001) and/or recently injected (P < 0.0001) drugs. Rapid HCV testing within jails is feasible, identifies previously unrecognized cases of HCV infection, and implementation should be considered. Low rates of linkage to care after release remain a barrier to care. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Hidden asymmetry and long range rapidity correlations
NASA Astrophysics Data System (ADS)
Bialas, A.; Bzdak, A.; Zalewski, K.
2012-04-01
Interpretation of long-range rapidity correlations in terms of the fluctuating rapidity density distribution of the system created in high-energy collisions is proposed. When applied to recent data of the STAR Collaboration, it shows a substantial asymmetric component in the shape of this system in central Au-Au collisions, implying that boost invariance is violated on the event-by-event basis even at central rapidity. This effect may seriously influence the hydrodynamic expansion of the system.
Fink, Günther; Maloney, Kathleen; Berg, Katrina; Jordan, Matthew; Svoronos, Theodore; Aber, Flavia; Dickens, William
2015-01-01
Abstract Objective To evaluate the impact – on diagnosis and treatment of malaria – of introducing rapid diagnostic tests to drug shops in eastern Uganda. Methods Overall, 2193 households in 79 study villages with at least one licensed drug shop were enrolled and monitored for 12 months. After 3 months of monitoring, drug shop vendors in 67 villages randomly selected for the intervention were offered training in the use of malaria rapid diagnostic tests and – if trained – offered access to such tests at a subsidized price. The remaining 12 study villages served as controls. A difference-in-differences regression model was used to estimate the impact of the intervention. Findings Vendors from 92 drug shops successfully completed training and 50 actively stocked and performed the rapid tests. Over 9 months, trained vendors did an average of 146 tests per shop. Households reported 22 697 episodes of febrile illness. The availability of rapid tests at local drug shops significantly increased the probability of any febrile illness being tested for malaria by 23.15% (P = 0.015) and being treated with an antimalarial drug by 8.84% (P = 0.056). The probability that artemisinin combination therapy was bought increased by a statistically insignificant 5.48% (P = 0.574). Conclusion In our study area, testing for malaria was increased by training drug shop vendors in the use of rapid tests and providing them access to such tests at a subsidized price. Additional interventions may be needed to achieve a higher coverage of testing and a higher rate of appropriate responses to test results.
Li, Youfang; Wang, Yumiao; Zhang, Renzhong; Wang, Jue; Li, Zhiqing; Wang, Ling; Pan, Songfeng; Yang, Yanling; Ma, Yanling; Jia, Manhong
2016-01-01
To understood the accuracy of oral fluid-based rapid HIV self-testing among men who have sex with men (MSM) and related factors. Survey was conducted among MSM selected through non-probability sampling to evaluate the quality of their rapid HIV self-testing, and related information was analyzed. The most MSM were aged 21-30 years (57.0%). Among them, 45.7% had educational level of college or above, 78.5% were unmarried, 59.3% were casual laborers. The overall accuracy rate of oral fluid based self-testing was 95.0%, the handling of"inserting test paper into tube as indicated by arrow on it"had the highest accuracy rate (98.0%), and the handling of"gently upsetting tube for 3 times"had lowest accuracy rate (65.0%); Chi-square analysis showed that educational level, no touch with middle part of test paper, whether reading the instruction carefully, whether understanding the instruction and inserting test paper into tube as indicated by the arrow on it were associated with the accuracy of oral fluid-based rapid HIV self-testing, (P<0.05). Multivariate logistic regression analysis indicated that educational level, no touch with middle part of test paper and understanding instructions were associated with the accuracy of oral fluid-based rapid HIV self-testing. The accuracy of oral fluid-based rapid HIV self-testing was high among MSM, the accuracy varied with the educational level of the MSM. Touch with the middle part of test paper or not and understanding the instructions or not might influence the accuracy of the self-testing.
Providing HIV results via SMS one day after testing: more popular than rapid point-of-care tests.
Davies, Stephen C; Koh, Andrew; Lindsay, Heather E; Fulton, Richard B; Fernando, Suran L
2017-06-01
An inner Sydney sexual health service introduced the option to gay and bisexual men of receiving a negative HIV result by SMS to mobile phone one business day after venipuncture (rapid SMS). Men could also choose one of the other options: a point-of-care-test (POCT), by phone, or in-person (clinicians could also require in-person). We followed-up patients choosing the rapid SMS method to ascertain their satisfaction. During 12 months, 473 men had 591 HIV tests. Of these tests, 5.4% were POCTs, 9.1% were in-person, 24% were by phone, and 62% were rapid SMS. HIV POCTs declined from being 22% of result methods in the pre-study period to 5.4% during the rapid SMS intervention period (odds ratio 0.20, 95% CI 0.13-0.32, P < 0.0001). Phone/in-person results declined from 78% to 33% (odds ratio 0.14, 95% CI 0.10-0.20, P < 0.0001). SMS was sent by the next business day in 95% of cases; 96% of men were satisfied; and 95% would choose this method for their next test. Of 77 men who previously had an HIV POCT, 56 (73%) elected a rapid SMS result rather than having another POCT. The higher accuracy of conventional serology was commonly expressed as the reason for choosing rapid SMS for results.
Horiuchi, Timothy K.
2011-01-01
Short-term synaptic plasticity acts as a time- and firing rate-dependent filter that mediates the transmission of information across synapses. In the avian auditory brainstem, specific forms of plasticity are expressed at different terminals of the same auditory nerve fibers and contribute to the divergence of acoustic timing and intensity information. To identify key differences in the plasticity properties, we made patch-clamp recordings from neurons in the cochlear nucleus responsible for intensity coding, nucleus angularis, and measured the time course of the recovery of excitatory postsynaptic currents following short-term synaptic depression. These synaptic responses showed a very rapid recovery, following a bi-exponential time course with a fast time constant of ~40 ms and a dependence on the presynaptic activity levels, resulting in a crossing over of the recovery trajectories following high-rate versus low-rate stimulation trains. We also show that the recorded recovery in the intensity pathway differs from similar recordings in the timing pathway, specifically the cochlear nucleus magnocellularis, in two ways: (1) a fast recovery that was not due to recovery from postsynaptic receptor desensitization and (2) a recovery trajectory that was characterized by a non-monotonic bump that may be due in part to facilitation mechanisms more prevalent in the intensity pathway. We tested whether a previously proposed model of synaptic transmission based on vesicle depletion and sequential steps of vesicle replenishment could account for the recovery responses, and found it was insufficient, suggesting an activity-dependent feedback mechanism is present. We propose that the rapid recovery following depression allows improved coding of natural auditory signals that often consist of sound bursts separated by short gaps. PMID:21409439
Convergent mechanisms underlying rapid antidepressant action
Zanos, Panos; Thompson, Scott M.; Duman, Ronald S.; Zarate, Carlos A.; Gould, Todd D.
2018-01-01
Traditional pharmacological treatments for depression have a delayed therapeutic onset, ranging from several weeks to months, and there is a high percentage of individuals who never respond to treatment. In contrast, ketamine produces rapid-onset antidepressant, anti-suicidal and anti-anhedonic actions following a single administration to depressed patients. Proposed mechanisms of ketamine’s antidepressant action include N-methyl-D-aspartate receptor (NMDAR) modulation, GABAergic interneuron disinhibition, and direct actions of its hydroxynorketamine (HNK) metabolites. Downstream actions include activation of mechanistic target of rapamycin (mTOR), deactivation of glycogen synthase kinase-3 and eukaryotic elongation factor 2 (eEF2), enhanced brain-derived neurotrophic factor (BDNF) signaling, and activation of α-amino-3-hydroxy-5-methyl-4-isoxazole-propionic acid receptors (AMPARs). These putative mechanisms of ketamine action are not mutually exclusive and may complement each other to induce potentiation of excitatory synapses in affective-regulating brain circuits, which results in amelioration of depression symptoms. We review these proposed mechanisms of ketamine action in the context of how such mechanisms are informing the development of novel putative rapid-acting antidepressant drugs. Such drugs that have undergoing pre-clinical, and in some cases clinical, testing include the muscarinic acetylcholine receptor antagonist scopolamine, GluN2B-NMDAR antagonists (i.e., CP-101,606, MK-0657), (2R,6R)-HNK, NMDAR glycine site modulators (i.e., 4-chlorokynurenine - pro-drug of the glycineB NMDAR antagonist 7-chlorokynurenic acid), NMDAR agonists (i.e. GLYX-13 (rapastinel)), metabotropic glutamate receptor 2/3 (mGluR2/3) antagonists, GABAA receptor modulators, and drugs acting on various serotonin receptor subtypes. These ongoing studies suggest that the future acute treatment of depression will typically occur within hours, rather than months, of treatment initiation. PMID:29516301
Thakur, Ranjit; Gupta, Ram B
2006-02-03
Nanoparticles are of significant importance in drug delivery. Rapid expansion of supercritical solution (RESS) process can produce pure and high-quality drug particles. However, due to extremely low solubility of polar drugs in supercritical CO(2) (sc CO(2)), RESS has limited commercial applicability. To overcome this major limitation, a modified process rapid expansion of supercritical solution with solid cosolvent (RESS-SC) is proposed which uses a solid cosolvent. Here, the new process is tested for phenytoin drug using menthol solid cosolvent. Phenytoin solubility in pure sc CO(2) is only 3 micromol/mol but when menthol solid cosolvent is used the solubility is enhanced to 1,302 micromol/mol, at 196 bar and 45 degrees C. This 400-fold increase in the solubility can be attributed to the interaction between phenytoin and menthol. Particle agglomeration in expansion zone is another major issue with conventional RESS process. In proposed RESS-SC process solid cosolvent hinders the particle growth resulting in the formation of small nanoparticles. For example, the average particle size of phenytoin in conventional RESS process is 200 nm whereas, with RESS-SC process, the average particle size is 120 nm, at 96 bar and 45 degrees C. Similarly at 196 bar and 45 degrees C, 105 nm average particles were obtained by RESS and 75 nm average particles were obtained in RESS-SC process. The particles obtained were characterized by Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), dynamic light scattering (DLS) and differential scanning calorimetery (DSC) analyses. Phenytoin nanoparticle production rate in RESS-SC is about 400-fold more in comparison to that in RESS process.
Merchant, Roland C; Gee, Erin M; Clark, Melissa A; Mayer, Kenneth H; Seage, George R; DeGruttola, Victor G
2007-01-01
Background Two trials were conducted to compare emergency department patient comprehension of rapid HIV pre-test information using different methods to deliver this information. Methods Patients were enrolled for these two trials at a US emergency department between February 2005 and January 2006. In Trial One, patients were randomized to a no pre-test information or an in-person discussion arm. In Trial Two, a separate group of patients were randomized to an in-person discussion arm or a Tablet PC-based video arm. The video, "Do you know about rapid HIV testing?", and the in-person discussion contained identical Centers for Disease Control and Prevention-suggested pre-test information components as well as information on rapid HIV testing with OraQuick®. Participants were compared by information arm on their comprehension of the pre-test information by their score on a 26-item questionnaire using the Wilcoxon rank-sum test. Results In Trial One, 38 patients completed the no-information arm and 31 completed the in-person discussion arm. Of these 69 patients, 63.8% had twelve years or fewer of formal education and 66.7% had previously been tested for HIV. The mean score on the questionnaire for the in-person discussion arm was higher than for the no information arm (18.7 vs. 13.3, p ≤ 0.0001). In Trial Two, 59 patients completed the in-person discussion and 55 completed the video arms. Of these 114 patients, 50.9% had twelve years or fewer of formal education and 68.4% had previously been tested for HIV. The mean score on the questionnaire for the video arm was similar to the in-person discussion arm (20.0 vs. 19.2; p ≤ 0.33). Conclusion The video "Do you know about rapid HIV testing?" appears to be an acceptable substitute for an in-person pre-test discussion on rapid HIV testing with OraQuick®. In terms of adequately informing ED patients about rapid HIV testing, either form of pre-test information is preferable than for patients to receive no pre-test information. PMID:17850670
Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.
Shivalli, Siddharudha
2016-05-12
Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.
Machado, A A; Martinez, R; Haikal, A A; Rodrigues da Silva, M C
2001-01-01
In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.
Cost analysis of a novel HIV testing strategy in community pharmacies and retail clinics.
Lecher, Shirley Lee; Shrestha, Ram K; Botts, Linda W; Alvarez, Jorge; Moore, James H; Thomas, Vasavi; Weidle, Paul J
2015-01-01
To document the cost of implementing point-of-care (POC) human immunodeficiency virus (HIV) rapid testing in busy community pharmacies and retail clinics. Providing HIV testing services in community pharmacies and retail clinics is an innovative way to expand HIV testing. The cost of implementing POC HIV rapid testing in a busy retail environment needs to be documented to provide program and policy leaders with adequate information for planning and budgeting. Cost analysis from a pilot project that provided confidential POC HIV rapid testing services in community pharmacies and retail clinics. The pharmacy sites were operated under several different ownership structures (for-profit, nonprofit, sole proprietorship, corporation, public, and private) in urban and rural areas. We included data from the initial six sites that participated in the project. We collected the time spent by pharmacy and retail clinic staff for pretest and posttest counseling in an activity log for time-in-motion for each interaction. Pharmacists and retail clinic staff. HIV rapid testing. The total cost was calculated to include costs of test kits, control kits, shipping, test supplies, training, reporting, program administration, and advertising. The six sites trained 22 staff to implement HIV testing. A total of 939 HIV rapid tests were conducted over a median time of 12 months, of which 17 were reactive. Median pretest counseling time was 2 minutes. Median posttest counseling time was 2 minutes for clients with a nonreactive test and 10 minutes for clients with a reactive test. The average cost per person tested was an estimated $47.21. When we considered only recurrent costs, the average cost per person tested was $32.17. Providing POC HIV rapid testing services required a modest amount of staff time and costs that are comparable to other services offered in these settings. HIV testing in pharmacies and retail clinics can provide an additional alternative venue for increasing the availability and accessibility of HIV testing services in the United States.
Time-lapse microscopy using smartphone with augmented reality markers.
Baek, Dongyoub; Cho, Sungmin; Yun, Kyungwon; Youn, Keehong; Bang, Hyunwoo
2014-04-01
A prototype system that replaces the conventional time-lapse imaging in microscopic inspection for use with smartphones is presented. Existing time-lapse imaging requires a video data feed between a microscope and a computer that varies depending on the type of image grabber. Even with proper hardware setups, a series of tedious and repetitive tasks is still required to relocate to the region-of-interest (ROI) of the specimens. In order to simplify the system and improve the efficiency of time-lapse imaging tasks, a smartphone-based platform utilizing microscopic augmented reality (μ-AR) markers is proposed. To evaluate the feasibility and efficiency of the proposed system, a user test was designed and performed, measuring the elapse time for a trial of the task starting from the execution of the application software to the completion of restoring and imaging of an ROI saved in advance. The results of the user test showed that the average elapse time was 65.3 ± 15.2 s with 6.86 ± 3.61 μm of position error and 0.08 ± 0.40 degrees of angle error. This indicates that the time-lapse imaging task was accomplished rapidly with a high level of accuracy. Thus, simplification of both the system and the task was achieved via our proposed system. Copyright © 2014 Wiley Periodicals, Inc.
Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report October 2014
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogden, Dan
Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report October 2014 Highlights • Rory Kennedy, Dan Ogden and Brenden Heidrich traveled to Germantown October 6-7, for a review of the Infrastructure Management mission with Shane Johnson, Mike Worley, Bradley Williams and Alison Hahn from NE-4 and Mary McCune from NE-3. Heidrich briefed the group on the project progress from July to October 2014 as well as the planned path forward for FY15. • Jim Cole gave two invited university seminars at Ohio State University and University of Florida, providing an overview of NSUF including available capabilities and themore » process for accessing facilities through the peer reviewed proposal process. • Jim Cole and Rory Kennedy co-chaired the NuMat meeting with Todd Allen. The meeting, sponsored by Elsevier publishing, was held in Clearwater, Florida, and is considered one of the premier nuclear fuels and materials conferences. Over 340 delegates attended with 160 oral and over 200 posters presented over 4 days. • Thirty-one pre-applications were submitted for NSUF access through the NE-4 Combined Innovative Nuclear Research Funding Opportunity Announcement. • Fourteen proposals were received for the NSUF Rapid Turnaround Experiment Summer 2014 call. Proposal evaluations are underway. • John Jackson and Rory Kennedy attended the Nuclear Fuels Industry Research meeting. Jackson presented an overview of ongoing NSUF industry research.« less
Plasmonic nanocarrier grid-enhanced Raman sensor for studies of anticancer drug delivery.
Kurzątkowska, Katarzyna; Santiago, Ty; Hepel, Maria
2017-05-15
Targeted drug delivery systems using nanoparticle nanocarriers offer remarkable promise for cancer therapy by discriminating against devastating cytotoxicity of chemotherapeutic drugs to healthy cells. To aid in the development of new drug nanocarriers, we propose a novel plasmonic nanocarrier grid-enhanced Raman sensor which can be applied for studies and testing of drug loading onto the nanocarriers, attachment of targeting ligands, dynamics of drug release, assessment of nanocarrier stability in biological environment, and general capabilities of the nanocarrier. The plasmonic nanogrid sensor offers strong Raman enhancement due to the overlapping plasmonic fields emanating from the nearest-neighbor gold nanoparticle nanocarriers and creating the enhancement "hot spots". The sensor has been tested for immobilization of an anticancer drug gemcitabine (2',2'-difluoro-2'-deoxycytidine, GEM) which is used in treatment of pancreatic tumors. The drawbacks of currently applied treatment include high systemic toxicity, rapid drug decay, and low efficacy (ca. 20%). Therefore, the development of a targeted GEM delivery system is highly desired. We have demonstrated that the proposed nanocarrier SERS sensor can be utilized to investigate attachment of targeting ligands to nanocarriers (attachment of folic acid ligand recognized by folate receptors of cancer cells is described). Further testing of the nanocarrier SERS sensor involved drug release induced by lowering pH and increasing GSH levels, both occurring in cancer cells. The proposed sensor can be utilized for a variety of drugs and targeting ligands, including those which are Raman inactive, since the linkers can act as the Raman markers, as illustrated with mercaptobenzoic acid and para-aminothiophenol. Copyright © 2017 Elsevier B.V. All rights reserved.
[Screening for psychiatric risk factors in a facial trauma patients. Validating a questionnaire].
Foletti, J M; Bruneau, S; Farisse, J; Thiery, G; Chossegros, C; Guyot, L
2014-12-01
We recorded similarities between patients managed in the psychiatry department and in the maxillo-facial surgical unit. Our hypothesis was that some psychiatric conditions act as risk factors for facial trauma. We had for aim to test our hypothesis and to validate a simple and efficient questionnaire to identify these psychiatric disorders. Fifty-eight consenting patients with facial trauma, recruited prospectively in the 3 maxillo-facial surgery departments of the Marseille area during 3 months (December 2012-March 2013) completed a self-questionnaire based on the French version of 3 validated screening tests (Self Reported Psychopathy test, Rapid Alcohol Problem Screening test quantity-frequency, and Personal Health Questionnaire). This preliminary study confirmed that psychiatric conditions detected by our questionnaire, namely alcohol abuse and dependence, substance abuse, and depression, were risk factors for facial trauma. Maxillo-facial surgeons are often unaware of psychiatric disorders that may be the cause of facial trauma. The self-screening test we propose allows documenting the psychiatric history of patients and implementing earlier psychiatric care. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, Steven A.; Lipinski, Ronald J.; Pandya, Tara
2005-02-06
Heat Pipe Reactors (HPR) for space power conversion systems offer a number of advantages not easily provided by other systems. They require no pumping, their design easily deals with freezing and thawing of the liquid metal, and they can provide substantial levels of redundancy. Nevertheless, no reactor has ever been operated and cooled with heat pipes, and the startup and other operational characteristics of these systems remain largely unknown. Signification deviations from normal reactor heat removal mechanisms exist, because the heat pipes have fundamental heat removal limits due to sonic flow issues at low temperatures. This paper proposes an earlymore » prototypic test of a Heat Pipe Reactor (using existing 20% enriched nuclear fuel pins) to determine the operational characteristics of the HPR. The proposed design is similar in design to the HOMER and SAFE-300 HPR designs (Elliot, Lipinski, and Poston, 2003; Houts, et. al, 2003). However, this reactor uses existing UZrH fuel pins that are coupled to potassium heat pipes modules. The prototype reactor would be located in the Sandia Annular Core Research Reactor Facility where the fuel pins currently reside. The proposed reactor would use the heat pipes to transport the heat from the UZrH fuel pins to a water pool above the core, and the heat transport to the water pool would be controlled by adjusting the pressure and gas type within a small annulus around each heat pipe. The reactor would operate as a self-critical assembly at power levels up to 200 kWth. Because the nuclear heated HPR test uses existing fuel and because it would be performed in an existing facility with the appropriate safety authorization basis, the test could be performed rapidly and inexpensively. This approach makes it possible to validate the operation of a HPR and also measure the feedback mechanisms for a typical HPR design. A test of this nature would be the world's first operating Heat Pipe Reactor. This reactor is therefore called 'HPR-1'.« less
Eller, Leigh A; Eller, Michael A; Ouma, Benson J; Kataaha, Peter; Bagaya, Bernard S; Olemukan, Robert L; Erima, Simon; Kawala, Lilian; de Souza, Mark S; Kibuuka, Hannah; Wabwire-Mangen, Fred; Peel, Sheila A; O'Connell, Robert J; Robb, Merlin L; Michael, Nelson L
2007-10-01
The use of rapid tests for human immunodeficiency virus (HIV) has become standard in HIV testing algorithms employed in resource-limited settings. We report an extensive HIV rapid test validation study conducted among Ugandan blood bank donors at low risk for HIV infection. The operational characteristics of four readily available commercial HIV rapid test kits were first determined with 940 donor samples and were used to select a serial testing algorithm. Uni-Gold Recombigen HIV was used as the screening test, followed by HIV-1/2 STAT-PAK for reactive samples. OraQuick HIV-1 testing was performed if the first two test results were discordant. This algorithm was then tested with 5,252 blood donor samples, and the results were compared to those of enzyme immunoassays (EIAs) and Western blotting. The unadjusted algorithm sensitivity and specificity were 98.6 and 99.9%, respectively. The adjusted sensitivity and specificity were 100 and 99.96%, respectively. This HIV testing algorithm is a suitable alternative to EIAs and Western blotting for Ugandan blood donors.
Redesign and Test of an SSME Turbopump for the Large Throat Main Combustion Chamber
NASA Technical Reports Server (NTRS)
Lunde, K. J.; Lee, G. A.; Eastland, A. H.; Rojas, L.
1994-01-01
The preburner oxidizer turbopump for the Space Shuttle Main Engine (SSME) was successfully redesigned for use with the Large Throat Main Combustion Chamber (LTMCC) and tested in air utilizing rapid prototyping. The redesign increases the SSME's operating range with the current Main Combustion Chamber (MCC) while achieving full operational range with the LTMCC. The use of rapid prototyping and air testing to validate the redesign demonstrated the ability to design, fabricate and test designs rapidly and at a very low cost.
2010-02-01
archived samples, we assessed the diagnostic capacity of a rapid immunochromatographic test (ICT) for the detection of Orientia tsutsugamushi IgM and...illness in the Asia-Pacific region. As very few health facilities have accessible accurate diagnostic tests , the diagnosis of scrub fever must be based...develop- ment of rapid , diagnostic tests by the use of immunochromato- graphic test (ICf) technologies has provided a mechanism for point-of-care
Rapid determination of alpha emitters using Actinide resin.
Navarro, N; Rodriguez, L; Alvarez, A; Sancho, C
2004-01-01
The European Commission has recently published the recommended radiological protection criteria for the clearance of building and building rubble from the dismantling of nuclear installations. Radionuclide specific clearance levels for actinides are very low (between 0.1 and 1 Bq g(-1)). The prevalence of natural radionuclides in rubble materials makes the verification of these levels by direct alpha counting impossible. The capability of Actinide resin (Eichrom Industries, Inc.) for extracting plutonium and americium from rubble samples has been tested in this work. Besides a strong affinity for actinides in the tri, tetra and hexavalent oxidation states, this extraction chromatographic resin presents an easy recovery of absorbed radionuclides. The retention capability was evaluated on rubble samples spiked with certified radionuclide standards (239Pu and 241Am). Samples were leached with nitric acid, passed through a chromatographic column containing the resin and the elution fraction was measured by LSC. Actinide retention varies from 60% to 80%. Based on these results, a rapid method for the verification of clearance levels for actinides in rubble samples is proposed.
Intraspecific competition favours niche width expansion in Drosophila melanogaster.
Bolnick, D I
2001-03-22
Ecologists have proposed that when interspecific competition is reduced, competition within a species becomes a potent evolutionary force leading to rapid diversification. This view reflects the observation that populations invading species-poor communities frequently evolve broader niches. Niche expansion can be associated with an increase in phenotypic variance (known as character release), with the evolution of polymorphisms, or with divergence into many species using distinct resources (adaptive radiation). The relationship between intraspecific competition and diversification is known from theory, and has been used as the foundation for some models of speciation. However, there has been little empirical proof that niches evolve in response to intraspecific competition. To test this hypothesis, I introduced cadmium-intolerant Drosophila melanogaster populations to environments containing both cadmium-free and cadmium-laced resources. Here I show that populations experiencing high competition adapted to cadmium more rapidly than low competition populations. This provides experimental confirmation that competition in a population can drive niche expansion onto new resources for which competition is less severe.
Xu, Fa-Xiang; Yuan, Cen; Wan, Jian-Bo; Yan, Ru; Hu, Hao; Li, Shao-Ping; Zhang, Qing-Wen
2015-01-01
A novel strategy for the qualitative and quantitative determination of 20(S)-protopanaxatriol saponins (PTS) and 20(S)-protopanaxadiol saponins (PDS) in Panax notoginseng, Panax ginseng and Panax quinquefolium, based on the overlapping peaks of main components of PTS (calibrated by ginsenoside Rg1) and PDS (calibrated by ginsenoside Rb1), was proposed. The analysis was performed by using high-performance liquid chromatography coupled with evaporative light scattering detection (HPLC-ELSD). Under specific chromatographic conditions, all samples showed two overlapping peaks containing several main ginsenosides belonging to PTS and PDS, respectively. The overlapping peaks were also identified by using HPLC-MS. Based on the sum and ratio of PTS and PDS, 60 tested Panax samples were divided into three main clusters according to their species. The findings suggested that this strategy provides a simple and rapid approach to quantify PTS and PDS in Panax herbs.
Rapid change in the thermal tolerance of a tropical lizard.
Leal, Manuel; Gunderson, Alex R
2012-12-01
The predominant view is that the thermal physiology of tropical ectotherms, including lizards, is not labile over ecological timescales. We used the recent introduction (∼35 years ago) of the Puerto Rican lizard Anolis cristatellus to Miami, Florida, to test this thermal rigidity hypothesis. We measured lower (critical thermal minimum [CT(min)]) and upper (critical thermal maximum [CT(max)]) thermal tolerances and found that the introduced population tolerates significantly colder temperatures (by ∼3°C) than does the Puerto Rican source population; however, CT(max) did not differ. These results mirror the thermal regimes experienced by each population: Miami reaches colder ambient temperatures than Puerto Rico, but maximum ambient temperatures are similar. The differences in CT(min) were observed even though lizards from both sites experienced nearly identical conditions for 49 days before CT(min) measurement. Our results demonstrate that changes in thermal tolerance occurred relatively rapidly (∼35 generations), which strongly suggests that the thermal physiology of tropical lizards is more labile than previously proposed.
Space time neural networks for tether operations in space
NASA Technical Reports Server (NTRS)
Lea, Robert N.; Villarreal, James A.; Jani, Yashvant; Copeland, Charles
1993-01-01
A space shuttle flight scheduled for 1992 will attempt to prove the feasibility of operating tethered payloads in earth orbit. due to the interaction between the Earth's magnetic field and current pulsing through the tether, the tethered system may exhibit a circular transverse oscillation referred to as the 'skiprope' phenomenon. Effective damping of skiprope motion depends on rapid and accurate detection of skiprope magnitude and phase. Because of non-linear dynamic coupling, the satellite attitude behavior has characteristic oscillations during the skiprope motion. Since the satellite attitude motion has many other perturbations, the relationship between the skiprope parameters and attitude time history is very involved and non-linear. We propose a Space-Time Neural Network implementation for filtering satellite rate gyro data to rapidly detect and predict skiprope magnitude and phase. Training and testing of the skiprope detection system will be performed using a validated Orbital Operations Simulator and Space-Time Neural Network software developed in the Software Technology Branch at NASA's Lyndon B. Johnson Space Center.
Vlasova, O P; German, K E; Krilov, V V; Petriev, V M; Epstein, N B
2015-01-01
About 10.7% cases of prostate cancer were registered in Russia in 2011 (40,000 patients). More than half of cancer cases were revealed in advanced (III-IV) stages when metastases inevitably developed quickly. Clinical problem of early diagnostics and treatment of metastatic prostate cancer is still not solved. Anatomical imaging techniques have low sensitivity and specificity for the detection of this disease. Metabolic visualization methods which use prostate specific antigen (PSA) as a marker are also ineffective. This article describes prostate-specific membrane antigens (PSMA) that are proposed as a marker for diagnostics and therapy of prostate cancer. The most promising PSMA-based radiopharmaceutical agent for diagnostics has been developed and clinically tested in the European countries. These pharmaceuticals are based on small peptide molecules modified with urea, and have the highest affinity to PSMA. Favorable phannacokinetics, rapid accumulation in the tumor and rapid excretion from the body are beneficial features of these pharmaceuticals.
Standardization of HPTLC method for the estimation of oxytocin in edibles.
Rani, Roopa; Medhe, Sharad; Raj, Kumar Rohit; Srivastava, Manmohan
2013-12-01
Adulteration in food stuff has been regarded as a major social evil and is a mind-boggling problem in society. In this study, a rapid, reliable and cost effective High Performance thin layer Chromatography (HPTLC) has been established for the estimation of oxytocin (adulterant) in vegetables, fruits and milk samples. Oxytocin is one of the most frequently used adulterant added in vegetables and fruits for increasing the growth rate and also to enhance milk production from lactating animals. The standardization of the method was based on simulation parameters of mobile phase, stationary phase and saturation time. The mobile phase used was MeOH: Ammonia (pH 6.8), optimized stationary phase was silica gel and saturation time of 5 min. The method was validated by testing its linearity, accuracy, precision, repeatability and limits of detection and quantification. Thus, the proposed method is simple, rapid and specific and was successfully employed for quality and quantity monitoring of oxytocin content in edible products.
Utility of the Determine Syphilis TP rapid test in commercial sex venues in Peru.
Campos, P E; Buffardi, A L; Chiappe, M; Buendía, C; Garcia, P J; Carcamo, C P; Garnett, G; White, P; Holmes, K K
2006-12-01
This study sought to evaluate the utility of the Determine Syphilis TP test performed in Peruvian commercial sex venues for the detection of active syphilis; and determine the feasibility of integrating rapid syphilis testing for female sex workers (FSW) into existing health outreach services. We tested 3586 female sex workers for syphilis by Determine in the field using whole blood fingerstick, and by rapid plasma reagin (RPR) and Treponema pallidum haemagglutination assay (TPHA) in a central laboratory in Lima using sera. 97.4% of the FSW offered rapid syphilis testing participated; and among those who tested positive, 87% visited the local health centre for treatment. More than twice as many specimens were RPR reactive using serum in Lima (5.7%) than tested positive by whole blood Determine in the field (2.8%), and although most were confirmed by TPHA, only a small proportion (0.7%) were RPR reactive at >or=1:8 dilutions, and likely indicating active syphilis. Sensitivity, specificity and positive predictive value of the Determine Syphilis TP test in whole blood when compared to serum RPR reactivity at any dilution confirmed by TPHA as the gold standard were 39.3%, 99.2% and 71.4%, respectively. Sensitivity improved to 64.0% when using serum RPR >or=1:8 confirmed by TPHA. Invalid tests were rare (0.3%). Rapid syphilis testing in sex work venues proved feasible, but Determine using whole blood obtained by fingerstick was substantially less sensitive than reported in previous laboratory-based studies using serum. Although easy to perform in outreach venues, the utility of this rapid syphilis test was relatively low in settings where a large proportion of the targeted population has been previously tested and treated.
Utility of the Determine Syphilis TP rapid test in commercial sex venues in Peru
Campos, P E; Buffardi, A L; Chiappe, M; Buendía, C; Garcia, P J; Carcamo, C P; Garnett, G; White, P
2006-01-01
Objectives This study sought to evaluate the utility of the Determine Syphilis TP test performed in Peruvian commercial sex venues for the detection of active syphilis; and determine the feasibility of integrating rapid syphilis testing for female sex workers (FSW) into existing health outreach services. Methods We tested 3586 female sex workers for syphilis by Determine in the field using whole blood fingerstick, and by rapid plasma reagin (RPR) and Treponema pallidum haemagglutination assay (TPHA) in a central laboratory in Lima using sera. Results 97.4% of the FSW offered rapid syphilis testing participated; and among those who tested positive, 87% visited the local health centre for treatment. More than twice as many specimens were RPR reactive using serum in Lima (5.7%) than tested positive by whole blood Determine in the field (2.8%), and although most were confirmed by TPHA, only a small proportion (0.7%) were RPR reactive at ⩾1:8 dilutions, and likely indicating active syphilis. Sensitivity, specificity and positive predictive value of the Determine Syphilis TP test in whole blood when compared to serum RPR reactivity at any dilution confirmed by TPHA as the gold standard were 39.3%, 99.2% and 71.4%, respectively. Sensitivity improved to 64.0% when using serum RPR ⩾1:8 confirmed by TPHA. Invalid tests were rare (0.3%). Conclusions Rapid syphilis testing in sex work venues proved feasible, but Determine using whole blood obtained by fingerstick was substantially less sensitive than reported in previous laboratory‐based studies using serum. Although easy to perform in outreach venues, the utility of this rapid syphilis test was relatively low in settings where a large proportion of the targeted population has been previously tested and treated. PMID:17116642
Ranjan, Rakesh; Narnaware, Shirish D; Nath, Kashi; Sawal, R K; Patil, N V
2018-04-01
Accurate early antemortem diagnosis of tuberculosis in dromedary camels is difficult due to the lack of reliable diagnostic test. The present study aimed to evaluate a lateral flow assay-based kit (rapid assay kit) in tuberculosis diagnosis that employs immuno-chromatographic detection of antibodies in serum, plasma, or whole blood. In a dromedary camel herd comprising 337 animals located at Bikaner, Rajasthan, India, 50 adult weak camels (11 males and 39 females) were tested by applying a single intradermal tuberculin test (SIDT) and rapid assay kit. A total of 14 animals (2 males, 12 females) were found positive in rapid assay. In SIDT, four animals revealed a positive reaction in the neck region and seven animals in the tail base. Another male animal was found SIDT positive but negative in rapid assay; it died after 12 months. Nine rapid assay positive animals died asymptomatically in 1- to 11-month period revealing postmortem tuberculosis lesions that were confirmed by Ziehl-Neelsen staining and histopathology. No tuberculous lesion was evident in the animal found positive in SIDT alone. Results of the present study indicated that serological tests like rapid assay kit can serve as a reliable test for antemortem diagnosis of tuberculosis in dromedary camel.
Izumida, Toshihide; Sakata, Hidenao; Nakamura, Masahiko; Hayashibara, Yumiko; Inasaki, Noriko; Inahata, Ryo; Hasegawa, Sumiyo; Takizawa, Takenori; Kaya, Hiroyasu
2016-01-01
An outbreak of dengue fever occurred in Japan in August 2014. We herein report the case of a 63-year-old man who presented with a persistent fever in September 2014. Acute parvovirus B19 infection led to a false positive finding of dengue fever on a rapid diagnostic test (Panbio Dengue Duo Cassette(TM)). To the best of our knowledge, there are no previous reports of a false positive result for dengue IgM with the dengue rapid diagnostic test. We believe that epidemiological information on the prevalence of parvovirus B19 is useful for guiding the interpretation of a positive result with the dengue rapid diagnostic test.
Cost-effectiveness of HIV and syphilis antenatal screening: a modeling study
Bristow, Claire C.; Larson, Elysia; Anderson, Laura J.; Klausner, Jeffrey D.
2016-01-01
Objectives The World Health Organization called for the elimination of maternal-to-child transmission (MTCT) of HIV and syphilis, a harmonized approach for the improvement of health outcomes for mothers and children. Testing early in pregnancy, treating seropositive pregnant women, and preventing syphilis re-infection can prevent MTCT of HIV and syphilis. We assessed the health and economic outcomes of a dual testing strategy in a simulated cohort of 100,000 antenatal care patients in Malawi. Methods We compared four screening algorithms: (1) HIV rapid test only, (2) dual HIV and syphilis rapid tests, (3) single rapid tests for HIV and syphilis, and (4) HIV rapid and syphilis laboratory tests. We calculated the expected number of adverse pregnancy outcomes, the expected costs, and the expected newborn disability adjusted life years (DALYs) for each screening algorithm. The estimated costs and DALYs for each screening algorithm were assessed from a societal perspective using Markov progression models. Additionally, we conducted a Monte Carlo multi-way sensitivity analysis, allowing for ranges of inputs. Results Our cohort decision model predicted the lowest number of adverse pregnancy outcomes in the dual HIV and syphilis rapid test strategy. Additionally, from the societal perspective, the costs of prevention and care using a dual HIV and syphilis rapid testing strategy was both the least costly ($226.92 per pregnancy) and resulted in the fewest DALYs (116,639) per 100,000 pregnancies. In the Monte Carlo simulation the dual HIV and syphilis algorithm was always cost saving and almost always reduced disability adjusted life years (DALYs) compared to HIV testing alone. Conclusion The results of the cost-effectiveness analysis showed that a dual HIV and syphilis test was cost saving compared to all other screening strategies. Adding dual rapid testing to the existing prevention of mother-to-child HIV transmission programs in Malawi and similar countries is likely to be advantageous. PMID:26920867
Simar, Shelby; Sibley, Diane; Ashcraft, Deborah; Pankey, George
2017-10-01
Polymyxin resistance is an increasing problem worldwide. Currently, determining susceptibility to polymyxins is problematic and lengthy. Polymyxins diffuse poorly into agar, potentially giving inaccurate disk diffusion and Etest results. A rapid screening test (2 h) for the detection of polymyxin resistance in Enterobacteriaceae , developed by P. Nordmann and L. Poirel (rapid polymyxin NP test) in 2016, detects glucose metabolization in the presence of polymyxin E (PE) and PB via pH-induced color change. The sensitivity and specificity were 99.3 and 95.4%, respectively, with results obtained in ≤2 h. Our goal was to evaluate this test using PB against larger numbers of Enterobacter A total of 143 nonduplicate Enterobacter isolates (102 E. cloacae complex, 41 E. aerogenes ) were tested, including 136 collected from Ochsner Health System patients from March to May 2016 and 7 previously determined PB-resistant E. cloacae isolates from JMI Laboratories. MICs were determined via broth microdilution. For the rapid polymyxin NP test, a color change from orange to yellow is positive; a weak/no color change is deemed negative after 4 h. Of 143 Enterobacter isolates, 25 were determined to be PB resistant by broth microdilution (MIC > 2 μg/ml), including all 7 JMI isolates. Of these 25, 7 were positive by the rapid polymyxin NP test (included 3/7 JMI isolates). All 118 isolates determined to be PB susceptible by broth microdilution were NP test negative. The sensitivity and specificity for the rapid polymyxin NP test were 25 and 100%, respectively, compared to broth microdilution. Although the rapid polymyxin NP test is a much faster method (2 to 4 h) for polymyxin resistance determination compared to broth microdilution (16 to 20 h), our study indicates that it may be subject to limitations when testing Enterobacter . Copyright © 2017 American Society for Microbiology.
EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats.
Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P M; Groschup, Martin H; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Van Keulen, Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi
2017-03-01
We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity, with the IDEXX test significantly more sensitive than the 2 Bio-Rad tests. All tests detected 100% of samples from goats with clinical scrapie, but missed 8% (IDEXX) to 33% (Bio-Rad SG) of samples from preclinical goats. Importantly, only IDEXX picked up all samples from clinical bovine spongiform encephalopathy (BSE)-infected goats, whereas the other 2 rapid tests missed 15% (Bio-Rad SG) to 25% (Bio-Rad SAP). These results show that a fraction of preclinical scrapie infections are likely missed by EU surveillance, with sensitivity of detection strongly dependent on the choice of the rapid test. Moreover, a significant proportion of clinical BSE infections are underestimated by using either Bio-Rad test. Assuming that the same sensitivity on preclinical goats would also occur in BSE-infected goats, our data suggest that IDEXX is likely the most sensitive test for detecting preclinical field cases of BSE infection in goats, although with an 8% failure rate. These results raise some concerns about the reliability of current EU surveillance figures on BSE infection in goats.
Intelligent Scheduling for Underground Mobile Mining Equipment
Song, Zhen; Schunnesson, Håkan; Rinne, Mikael; Sturgul, John
2015-01-01
Many studies have been carried out and many commercial software applications have been developed to improve the performances of surface mining operations, especially for the loader-trucks cycle of surface mining. However, there have been quite few studies aiming to improve the mining process of underground mines. In underground mines, mobile mining equipment is mostly scheduled instinctively, without theoretical support for these decisions. Furthermore, in case of unexpected events, it is hard for miners to rapidly find solutions to reschedule and to adapt the changes. This investigation first introduces the motivation, the technical background, and then the objective of the study. A decision support instrument (i.e. schedule optimizer for mobile mining equipment) is proposed and described to address this issue. The method and related algorithms which are used in this instrument are presented and discussed. The proposed method was tested by using a real case of Kittilä mine located in Finland. The result suggests that the proposed method can considerably improve the working efficiency and reduce the working time of the underground mine. PMID:26098934
Luo, Junhai; Fu, Liang
2017-06-09
With the development of communication technology, the demand for location-based services is growing rapidly. This paper presents an algorithm for indoor localization based on Received Signal Strength (RSS), which is collected from Access Points (APs). The proposed localization algorithm contains the offline information acquisition phase and online positioning phase. Firstly, the AP selection algorithm is reviewed and improved based on the stability of signals to remove useless AP; secondly, Kernel Principal Component Analysis (KPCA) is analyzed and used to remove the data redundancy and maintain useful characteristics for nonlinear feature extraction; thirdly, the Affinity Propagation Clustering (APC) algorithm utilizes RSS values to classify data samples and narrow the positioning range. In the online positioning phase, the classified data will be matched with the testing data to determine the position area, and the Maximum Likelihood (ML) estimate will be employed for precise positioning. Eventually, the proposed algorithm is implemented in a real-world environment for performance evaluation. Experimental results demonstrate that the proposed algorithm improves the accuracy and computational complexity.
Force Rendering and its Evaluation of a Friction-Based Walking Sensation Display for a Seated User.
Kato, Ginga; Kuroda, Yoshihiro; Kiyokawa, Kiyoshi; Takemura, Haruo
2018-04-01
Most existing locomotion devices that represent the sensation of walking target a user who is actually performing a walking motion. Here, we attempted to represent the walking sensation, especially a kinesthetic sensation and advancing feeling (the sense of moving forward) while the user remains seated. To represent the walking sensation using a relatively simple device, we focused on the force rendering and its evaluation of the longitudinal friction force applied on the sole during walking. Based on the measurement of the friction force applied on the sole during actual walking, we developed a novel friction force display that can present the friction force without the influence of body weight. Using performance evaluation testing, we found that the proposed method can stably and rapidly display friction force. Also, we developed a virtual reality (VR) walk-through system that is able to present the friction force through the proposed device according to the avatar's walking motion in a virtual world. By evaluating the realism, we found that the proposed device can represent a more realistic advancing feeling than vibration feedback.
NASA Astrophysics Data System (ADS)
Li, Hutian; Guo, Jianting; Huai, Kaiwen; Ye, Hengqiang
2006-04-01
The microstructure and room temperature compressive deformation behavior of a rapidly solidified NiAl-Cr(Mo)-Dy eutectic alloy fabricated by water-cooled copper mold method were studied by a combination of SEM, EDS and compressive tests. The morphology stability after hot isostatic pressing (HIP) treatment was evaluated. Rapid solidification resulted in a shift in the coupled zone for the eutectic growth towards the Cr(Mo) phase, indicating a hypoeutectic composition, hence increasing the volume fraction of primary dendritic NiAl. Meanwhile, significantly refined microstructure and lamellar/rod-like Cr(Mo) transition were observed due to trace rare earth (RE) element Dy addition and rapid solidification effects. Compared with the results in literature [H.E. Cline, J.L. Walter, Metall. Trans. 1(1970)2907-2917; P. Ferrandini, W.W. Batista, R. Caram, J. Alloys Comp. 381(2004)91-98], an interesting phenomenon, viz., NiAl halos around the primary Cr(Mo) dendrites in solidified NiAl-Cr(Mo) hypereutectic alloy, was not observed in this study. This difference was interpreted in terms of their different reciprocal nucleation ability. In addition, it was proposed that the localized destabilization of morphology after HIP treatment is closely related to the presence of primary NiAl dendrites. The improved mechanical properties can be attributed to the synergistic effects of rapid solidification and Dy addition, which included refined microstructure, suppression of the crack development along eutectic grain boundaries, enhancement of density of geometrically necessary dislocations located at NiAl/Cr(Mo) interfaces and the Cr solubility extension in NiAl.
Goenka, Anu; Jeena, Prakash M; Mlisana, Koleka; Solomon, Tom; Spicer, Kevin; Stephenson, Rebecca; Verma, Arpana; Dhada, Barnesh; Griffiths, Michael J
2018-03-01
Early diagnosis of tuberculous meningitis (TBM) is crucial to achieve optimum outcomes. There is no effective rapid diagnostic test for use in children. We aimed to develop a clinical decision tool to facilitate the early diagnosis of childhood TBM. Retrospective case-control study was performed across 7 hospitals in KwaZulu-Natal, South Africa (2010-2014). We identified the variables most predictive of microbiologically confirmed TBM in children (3 months to 15 years) by univariate analysis. These variables were modelled into a clinical decision tool and performance tested on an independent sample group. Of 865 children with suspected TBM, 3% (25) were identified with microbiologically confirmed TBM. Clinical information was retrieved for 22 microbiologically confirmed cases of TBM and compared with 66 controls matched for age, ethnicity, sex and geographical origin. The 9 most predictive variables among the confirmed cases were used to develop a clinical decision tool (CHILD TB LP): altered Consciousness; caregiver HIV infected; Illness length >7 days; Lethargy; focal neurologic Deficit; failure to Thrive; Blood/serum sodium <132 mmol/L; CSF >10 Lymphocytes ×10/L; CSF Protein >0.65 g/L. This tool successfully classified an independent sample of 7 cases and 21 controls with a sensitivity of 100% and specificity of 90%. The CHILD TB LP decision tool accurately classified microbiologically confirmed TBM. We propose that CHILD TB LP is prospectively evaluated as a novel rapid diagnostic tool for use in the initial evaluation of children with suspected neurologic infection presenting to hospitals in similar settings.
Making vaccines "on demand": a potential solution for emerging pathogens and biodefense?
De Groot, Anne S; Einck, Leo; Moise, Leonard; Chambers, Michael; Ballantyne, John; Malone, Robert W; Ardito, Matthew; Martin, William
2013-09-01
The integrated US Public Health Emergency Medical Countermeasures Enterprise (PHEMCE) has made great strides in strategic preparedness and response capabilities. There have been numerous advances in planning, biothreat countermeasure development, licensure, manufacturing, stockpiling and deployment. Increased biodefense surveillance capability has dramatically improved, while new tools and increased awareness have fostered rapid identification of new potential public health pathogens. Unfortunately, structural delays in vaccine design, development, manufacture, clinical testing and licensure processes remain significant obstacles to an effective national biodefense rapid response capability. This is particularly true for the very real threat of "novel pathogens" such as the avian-origin influenzas H7N9 and H5N1, and new coronaviruses such as hCoV-EMC. Conventional approaches to vaccine development, production, clinical testing and licensure are incompatible with the prompt deployment needed for an effective public health response. An alternative approach, proposed here, is to apply computational vaccine design tools and rapid production technologies that now make it possible to engineer vaccines for novel emerging pathogen and WMD biowarfare agent countermeasures in record time. These new tools have the potential to significantly reduce the time needed to design string-of-epitope vaccines for previously unknown pathogens. The design process-from genome to gene sequence, ready to insert in a DNA plasmid-can now be accomplished in less than 24 h. While these vaccines are by no means "standard," the need for innovation in the vaccine design and production process is great. Should such vaccines be developed, their 60-d start-to-finish timeline would represent a 2-fold faster response than the current standard.
Stuart, Sarah A; Butler, Paul; Munafò, Marcus R; Nutt, David J; Robinson, Emma SJ
2015-01-01
The biochemical targets for antidepressants are relatively well established, but we lack a clear understanding of how actions at these proteins translate to clinical benefits. This study used a novel rodent assay to investigate how different antidepressant drugs act to modify affective biases that have been implicated in depression. In this bowl-digging task, rats encounter two equal value learning experiences on separate days (one during an affective manipulation and the other during control conditions). This induces an affective bias that is quantified using a preference test in which both digging substrates are presented together and the individual rats’ choices recorded. The assay can be used to measure affective biases associated with learning (when the treatment is given at the time of the experience) or examine the modification of previously acquired biases (when the treatment is administered before the preference test). The rapid-onset antidepressant ketamine, but not the delayed-onset antidepressant, venlafaxine, attenuated the previously acquired FG7142-induced negative bias following systemic administration. Venlafaxine but not ketamine induced a positive bias when administered before learning. We then used local drug infusions and excitotoxic lesions to localize the effects of ketamine to the medial prefrontal cortex and venlafaxine to the amygdala. Using a modified protocol we also showed that positive and negative biases amplified further when the numbers of substrate–reinforcer associations are increased. We propose that this pattern of results could explain the delayed onset of action of venlafaxine and the rapid onset of action but lack of long-term efficacy seen with ketamine. PMID:25740288
De Groot, Anne S; Einck, Leo; Moise, Leonard; Chambers, Michael; Ballantyne, John; Malone, Robert W; Ardito, Matthew; Martin, William
2013-01-01
The integrated US Public Health Emergency Medical Countermeasures Enterprise (PHEMCE) has made great strides in strategic preparedness and response capabilities. There have been numerous advances in planning, biothreat countermeasure development, licensure, manufacturing, stockpiling and deployment. Increased biodefense surveillance capability has dramatically improved, while new tools and increased awareness have fostered rapid identification of new potential public health pathogens. Unfortunately, structural delays in vaccine design, development, manufacture, clinical testing and licensure processes remain significant obstacles to an effective national biodefense rapid response capability. This is particularly true for the very real threat of “novel pathogens” such as the avian-origin influenzas H7N9 and H5N1, and new coronaviruses such as hCoV-EMC. Conventional approaches to vaccine development, production, clinical testing and licensure are incompatible with the prompt deployment needed for an effective public health response. An alternative approach, proposed here, is to apply computational vaccine design tools and rapid production technologies that now make it possible to engineer vaccines for novel emerging pathogen and WMD biowarfare agent countermeasures in record time. These new tools have the potential to significantly reduce the time needed to design string-of-epitope vaccines for previously unknown pathogens. The design process—from genome to gene sequence, ready to insert in a DNA plasmid—can now be accomplished in less than 24 h. While these vaccines are by no means “standard,” the need for innovation in the vaccine design and production process is great. Should such vaccines be developed, their 60-d start-to-finish timeline would represent a 2-fold faster response than the current standard. PMID:23877094
Supplanting the rapid chloride permeability test with a quick measurement of concrete conductivity.
DOT National Transportation Integrated Search
2005-01-01
The rapid chloride permeability test (RCPT) (AASHTO T 277, ASTM C 1202) is increasingly being used as an acceptance test for concrete constructions in the transportation industry. As more and more projects are subject to such testing, the capabilitie...
NASA Astrophysics Data System (ADS)
Xiao, Yang
With the rapid development of China's foreign trade, now many universities have set up the International Trade major one after another; The University must be based on our own resources superiority to have the scientific orientation of personnel training objectives, which can make trained students meet needs of society and enterprises better. This paper based on the characteristics of International Trade major in University proposes to take the personnel training model combining with "Work, Certificate and Learning" as the objective, proceeding the orientation of professional personnel and settings of certificate testing module and teaching module, to construct the curriculum system from the innovation of theoretical and practical teaching.
Automatic Target Recognition Based on Cross-Plot
Wong, Kelvin Kian Loong; Abbott, Derek
2011-01-01
Automatic target recognition that relies on rapid feature extraction of real-time target from photo-realistic imaging will enable efficient identification of target patterns. To achieve this objective, Cross-plots of binary patterns are explored as potential signatures for the observed target by high-speed capture of the crucial spatial features using minimal computational resources. Target recognition was implemented based on the proposed pattern recognition concept and tested rigorously for its precision and recall performance. We conclude that Cross-plotting is able to produce a digital fingerprint of a target that correlates efficiently and effectively to signatures of patterns having its identity in a target repository. PMID:21980508
Computing exact bundle compliance control charts via probability generating functions.
Chen, Binchao; Matis, Timothy; Benneyan, James
2016-06-01
Compliance to evidenced-base practices, individually and in 'bundles', remains an important focus of healthcare quality improvement for many clinical conditions. The exact probability distribution of composite bundle compliance measures used to develop corresponding control charts and other statistical tests is based on a fairly large convolution whose direct calculation can be computationally prohibitive. Various series expansions and other approximation approaches have been proposed, each with computational and accuracy tradeoffs, especially in the tails. This same probability distribution also arises in other important healthcare applications, such as for risk-adjusted outcomes and bed demand prediction, with the same computational difficulties. As an alternative, we use probability generating functions to rapidly obtain exact results and illustrate the improved accuracy and detection over other methods. Numerical testing across a wide range of applications demonstrates the computational efficiency and accuracy of this approach.
Bogart, Laura M; Howerton, Devery; Lange, James; Setodji, Claude Messan; Becker, Kirsten; Klein, David J; Asch, Steven M
2010-06-01
We examined provider-reported barriers to rapid HIV testing in U.S. urban non-profit community clinics, community-based organizations (CBOs), and hospitals. 12 primary metropolitan statistical areas (PMSAs; three per region) were sampled randomly, with sampling weights proportional to AIDS case reports. Across PMSAs, all 671 hospitals and a random sample of 738 clinics/CBOs were telephoned for a survey on rapid HIV test availability. Of the 671 hospitals, 172 hospitals were randomly selected for barriers questions, for which 158 laboratory and 136 department staff were eligible and interviewed in 2005. Of the 738 clinics/CBOs, 276 were randomly selected for barriers questions, 206 were reached, and 118 were eligible and interviewed in 2005-2006. In multivariate models, barriers regarding translation of administrative/quality assurance policies into practice were significantly associated with rapid HIV testing availability. For greater rapid testing diffusion, policies are needed to reduce administrative barriers and provide quality assurance training to non-laboratory staff.
Fraisse, Thibaut; Fourcade, Camille; Brazes-Sanz, Julie; Koumar, Yatrika; Lavigne, Jean Philippe; Sotto, Albert; Laureillard, Didier
2016-10-01
In France, almost 30,000 people are unaware of their HIV-positive status. Innovative screening strategies are essential to reach this population. The aim of this study was to describe the acceptability of rapid HIV testing (RHT) among French general practitioners (GPs) working in the south of France and barriers for implementing this strategy. We analysed an anonymous questionnaire sent by mail to GPs about demographic data, routine practice, knowledge of RHT and barriers to its use. Between 1 April and 30 September 2013, out of the 165 GPs contacted, 78 returned the questionnaires. The GPs' mean age was 52 years; 49 were men. Fifty-one GPs reported that their registered patients included at least one HIV-infected person and 70 GPs reported taking care of high-risk patients. Sixty-three percent of GPs reported being interested in using RHT in their daily practice. The main reasons reported by uninterested GPs were: greater confidence in standard HIV testing, difficulties including RHT during the routine consultation, difficulties to screen for other sexually transmitted infections simultaneously, and difficulties to deliver a positive result. French National Authorities for Health propose to screen the population at least once in their lifetime and high-risk people at least once a year. In order to achieve this aim, RHT should be included in the GPs' arsenal for HIV testing. We showed a high acceptability of RHT by GPs. If specific and adapted training is developed, and if solutions to barriers reported by GPs are found, RHT could be implemented in to their routine activity. © The Author(s) 2016.
Jiang, Wei; Liu, Yingchun; Chen, Yongjun; Yang, Qiufeng; Chun, Peter; Yao, Kailing; Han, Xiangan; Wang, Shaohui; Yu, Shengqing; Liu, Yongjie; Wang, Quan
2015-10-15
A novel dynamic flow immunochromatographic test (DFICT) is proposed for rapid assay utilizing Toxoplasma gondii as a model. The test is based on a proprietary technology that combines the principles of immunochromatography and fluid dynamics. Gold nanoparticles conjugated to staphylococcal protein A (SPA) were prepared in liquid form and used as signal vehicles. T. gondii-specific recombinant antigens and SPA were sprayed onto a nitrocellulose membrane in strips at positions designated as T and C, respectively. The DFICT is performed by applying a 100 µL aliquot of liquid gold-SPA conjugate to the reagent hole and a 5 μL aliquot of serum sample to the sample hole. The results were observable within 5 min by the naked eye. The lowest detectable limit of the assay was determined as the highest dilution (1:320) of positive serum. No cross-reaction of the antibodies with other related canine or feline pathogens was observed. The DFICT can be stored for 12 months at 4°C or 6 months with no loss of sensitivity or specificity. A high degree of consistency was observed between the DFICT and the standard ELISA kit, supporting the reliability of the novel test strip. The introduction of a liquid gold nanoparticle conjugate reagent provides this method with several attractive characteristics, such as ease of manufacture, low sample volume requirements, high selectivity and high efficiency. This method opens a novel pathway for rapid diagnostic screening and field analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Xiao, Feng; Kong, Lingjiang; Chen, Jian
2017-06-01
A rapid-search algorithm to improve the beam-steering efficiency for a liquid crystal optical phased array was proposed and experimentally demonstrated in this paper. This proposed algorithm, in which the value of steering efficiency is taken as the objective function and the controlling voltage codes are considered as the optimization variables, consisted of a detection stage and a construction stage. It optimized the steering efficiency in the detection stage and adjusted its search direction adaptively in the construction stage to avoid getting caught in a wrong search space. Simulations had been conducted to compare the proposed algorithm with the widely used pattern-search algorithm using criteria of convergence rate and optimized efficiency. Beam-steering optimization experiments had been performed to verify the validity of the proposed method.
Feaster, Daniel J.; Gooden, Lauren; Matheson, Tim; Mandler, Raul N.; Haynes, Louise; Tross, Susan; Kyle, Tiffany; Gallup, Dianne; Kosinski, Andrzej S.; Douaihy, Antoine; Schackman, Bruce R.; Das, Moupali; Lindblad, Robert; Erickson, Sarah; Korthuis, P. Todd; Martino, Steve; Sorensen, James L.; Szapocznik, José; Walensky, Rochelle; Branson, Bernard; Colfax, Grant N.
2012-01-01
Objectives. We examined the effectiveness of risk reduction counseling and the role of on-site HIV testing in drug treatment. Methods. Between January and May 2009, we randomized 1281 HIV-negative (or status unknown) adults who reported no past-year HIV testing to (1) referral for off-site HIV testing, (2) HIV risk-reduction counseling with on-site rapid HIV testing, or (3) verbal information about testing only with on-site rapid HIV testing. Results. We defined 2 primary self-reported outcomes a priori: receipt of HIV test results and unprotected anal or vaginal intercourse episodes at 6-month follow-up. The combined on-site rapid testing participants received more HIV test results than off-site testing referral participants (P < .001; Mantel-Haenszel risk ratio = 4.52; 97.5% confidence interval [CI] = 3.57, 5.72). At 6 months, there were no significant differences in unprotected intercourse episodes between the combined on-site testing arms and the referral arm (P = .39; incidence rate ratio [IRR] = 1.04; 97.5% CI = 0.95, 1.14) or the 2 on-site testing arms (P = .81; IRR = 1.03; 97.5% CI = 0.84, 1.26). Conclusions. This study demonstrated on-site rapid HIV testing’s value in drug treatment centers and found no additional benefit from HIV sexual risk-reduction counseling. PMID:22515871
Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng
2015-01-01
The non-sugar solids (NSS) content is one of the most important nutrition indicators of Chinese rice wine. This study proposed a rapid method for the measurement of NSS content in Chinese rice wine using near infrared (NIR) spectroscopy. We also systemically studied the efficient spectral variables selection algorithms that have to go through modeling. A new algorithm of synergy interval partial least square with competitive adaptive reweighted sampling (Si-CARS-PLS) was proposed for modeling. The performance of the final model was back-evaluated using root mean square error of calibration (RMSEC) and correlation coefficient (Rc) in calibration set and similarly tested by mean square error of prediction (RMSEP) and correlation coefficient (Rp) in prediction set. The optimum model by Si-CARS-PLS algorithm was achieved when 7 PLS factors and 18 variables were included, and the results were as follows: Rc=0.95 and RMSEC=1.12 in the calibration set, Rp=0.95 and RMSEP=1.22 in the prediction set. In addition, Si-CARS-PLS algorithm showed its superiority when compared with the commonly used algorithms in multivariate calibration. This work demonstrated that NIR spectroscopy technique combined with a suitable multivariate calibration algorithm has a high potential in rapid measurement of NSS content in Chinese rice wine. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhang, Yufeng; Xiao, Shun; Sun, Lijuan; Ge, Zhiwei; Fang, Fengkai; Zhang, Wen; Wang, Yi; Cheng, Yiyu
2013-05-13
A high throughput method was developed for rapid screening and identification of bioactive compounds from traditional Chinese medicine, marine products and other natural products. The system, integrated with five-channel chromatographic separation and dual UV-MS detection, is compatible with in vitro 96-well microplate based bioassays. The stability and applicability of the proposed method was validated by testing radical scavenging capability of a mixture of seven known compounds (rutin, dihydroquercetin, salvianolic acid A, salvianolic acid B, glycyrrhizic acid, rubescensin A and tangeretin). Moreover, the proposed method was successfully applied to the crude extracts of traditional Chinese medicine and a marine sponge from which 12 bioactive compounds were screened and characterized based on their anti-oxidative or anti-tumor activities. In particular, two diterpenoid derivatives, agelasine B and (-)-agelasine D, were identified for the first time as anti-tumor compounds from the sponge Agelas mauritiana, showing a considerable activity toward MCF-7 cells (IC50 values of 7.84±0.65 and 10.48±0.84 μM, respectively). Our findings suggested that the integrated system of 5-channel parallel chromatography coupled with on-line mass spectrometry and microplate based assays can be a versatile and high efficient approach for the discovery of active compounds from natural products. Copyright © 2013 Elsevier B.V. All rights reserved.
Chen, Xin; Zhang, Ye; Zhang, Jingna; Li, Ying; Mo, Xuemei; Chen, Wei
2017-01-01
This study aimed to propose a pure web-based solution to serve users to access large-scale 3D medical volume anywhere with good user experience and complete details. A novel solution of the Master-Slave interaction mode was proposed, which absorbed advantages of remote volume rendering and surface rendering. On server side, we designed a message-responding mechanism to listen to interactive requests from clients (Slave model) and to guide Master volume rendering. On client side, we used HTML5 to normalize user-interactive behaviors on Slave model and enhance the accuracy of behavior request and user-friendly experience. The results showed that more than four independent tasks (each with a data size of 249.4 MB) could be simultaneously carried out with a 100-KBps client bandwidth (extreme test); the first loading time was <12 s, and the response time of each behavior request for final high quality image remained at approximately 1 s, while the peak value of bandwidth was <50-KBps. Meanwhile, the FPS value for each client was ≥40. This solution could serve the users by rapidly accessing the application via one URL hyperlink without special software and hardware requirement in a diversified network environment and could be easily integrated into other telemedical systems seamlessly. PMID:28638406
Qiao, Liang; Chen, Xin; Zhang, Ye; Zhang, Jingna; Wu, Yi; Li, Ying; Mo, Xuemei; Chen, Wei; Xie, Bing; Qiu, Mingguo
2017-01-01
This study aimed to propose a pure web-based solution to serve users to access large-scale 3D medical volume anywhere with good user experience and complete details. A novel solution of the Master-Slave interaction mode was proposed, which absorbed advantages of remote volume rendering and surface rendering. On server side, we designed a message-responding mechanism to listen to interactive requests from clients ( Slave model) and to guide Master volume rendering. On client side, we used HTML5 to normalize user-interactive behaviors on Slave model and enhance the accuracy of behavior request and user-friendly experience. The results showed that more than four independent tasks (each with a data size of 249.4 MB) could be simultaneously carried out with a 100-KBps client bandwidth (extreme test); the first loading time was <12 s, and the response time of each behavior request for final high quality image remained at approximately 1 s, while the peak value of bandwidth was <50-KBps. Meanwhile, the FPS value for each client was ≥40. This solution could serve the users by rapidly accessing the application via one URL hyperlink without special software and hardware requirement in a diversified network environment and could be easily integrated into other telemedical systems seamlessly.
Yang, Xiao; Diao, Chun-Peng; Sun, Ai-Ling; Liu, Ren-Min
2014-10-01
A method for the rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection was proposed in this paper. A simple apparatus consisting of a test tube and a cut-glass dropper was designed and applied to collect the floating extraction drop in liquid-liquid microextraction when low-density organic solvent was used as the extraction solvent. Solidification and melting steps that were tedious but necessary once the low-density organic solvent used as extraction solvent could be avoided by using this apparatus. Bisphenol A was selected as model pollutant and vortex-assisted liquid-liquid microextraction was employed to investigate the usefulness of the apparatus. High-performance liquid chromatography with fluorescence detection was selected as the analytical tool for the detection of bisphenol A. The linear dynamic range was from 0.10 to 100 μg/L for bisphenol A, with good squared regression coefficient (r(2) = 0.9990). The relative standard deviation (n = 7) was 4.7% and the limit of detection was 0.02 μg/L. The proposed method had been applied to the determination of bisphenol A in natural water samples and was shown to be economical, fast, and convenient. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E
2013-01-01
To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.
WMATA Rapid Transit Vehicle Engineering Tests
DOT National Transportation Integrated Search
1979-05-01
TSC has been instrumental in preparing standardized test procedures for evaluation of rail transit vehicles, using the TTC's 9.1 mile Transit Test Track, with the objective of providing a common baseline for the comparative evaluation of rapid transi...
Assoumou, Sabrina A; Tasillo, Abriana; Leff, Jared A; Schackman, Bruce R; Drainoni, Mari-Lynn; Horsburgh, C Robert; Barry, M Anita; Regis, Craig; Kim, Arthur Y; Marshall, Alison; Saxena, Sheel; Smith, Peter C; Linas, Benjamin P
2018-01-18
High hepatitis C virus (HCV) rates have been reported in young people who inject drugs (PWID). We evaluated the clinical benefit and cost-effectiveness of testing among youth seen in communities with a high overall number of reported HCV cases. We developed a decision analytic model to project quality-adjusted life years (QALYs), costs (2016 US$), and incremental cost-effectiveness ratios (ICERs) of 9 strategies for 1-time testing among 15- to 30-year-olds seen at urban community health centers. Strategies differed in 3 ways: targeted vs routine testing, rapid finger stick vs standard venipuncture, and ordered by physician vs by counselor/tester using standing orders. We performed deterministic and probabilistic sensitivity analyses (PSA) to evaluate uncertainty. Compared to targeted risk-based testing (current standard of care), routine testing increased the lifetime medical cost by $80 and discounted QALYs by 0.0013 per person. Across all strategies, rapid testing provided higher QALYs at a lower cost per QALY gained and was always preferred. Counselor-initiated routine rapid testing was associated with an ICER of $71000/QALY gained. Results were sensitive to offer and result receipt rates. Counselor-initiated routine rapid testing was cost-effective (ICER <$100000/QALY) unless the prevalence of PWID was <0.59%, HCV prevalence among PWID was <16%, reinfection rate was >26 cases per 100 person-years, or reflex confirmatory testing followed all reactive venipuncture diagnostics. In PSA, routine rapid testing was the optimal strategy in 90% of simulations. Routine rapid HCV testing among 15- to 30-year-olds may be cost-effective when the prevalence of PWID is >0.59%. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A
2012-12-01
Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.
Why Blue stragglers formed via collisions may not be rapid rotators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leonard, P.J.T.; Clement, M.J.
1993-03-01
We propose that the blue stragglers formed via collisions may not be rapid rotators due to magnetic braking during a Hayashi phase as they approach the main sequence. It is conceivable that just the envelopes of the blue stragglers are spun down, while their cores remain rapidly rotating. This would greatly extend the main-sequence lifetimes of the blue stragglers produced by collisions.
Why Blue stragglers formed via collisions may not be rapid rotators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leonard, P.J.T.; Clement, M.J.
1993-01-01
We propose that the blue stragglers formed via collisions may not be rapid rotators due to magnetic braking during a Hayashi phase as they approach the main sequence. It is conceivable that just the envelopes of the blue stragglers are spun down, while their cores remain rapidly rotating. This would greatly extend the main-sequence lifetimes of the blue stragglers produced by collisions.
Fernández-Fernández, Mario; Rodríguez-González, Pablo; García Alonso, J Ignacio
2016-10-01
We have developed a novel, rapid and easy calculation procedure for Mass Isotopomer Distribution Analysis based on multiple linear regression which allows the simultaneous calculation of the precursor pool enrichment and the fraction of newly synthesized labelled proteins (fractional synthesis) using linear algebra. To test this approach, we used the peptide RGGGLK as a model tryptic peptide containing three subunits of glycine. We selected glycine labelled in two 13 C atoms ( 13 C 2 -glycine) as labelled amino acid to demonstrate that spectral overlap is not a problem in the proposed methodology. The developed methodology was tested first in vitro by changing the precursor pool enrichment from 10 to 40% of 13 C 2 -glycine. Secondly, a simulated in vivo synthesis of proteins was designed by combining the natural abundance RGGGLK peptide and 10 or 20% 13 C 2 -glycine at 1 : 1, 1 : 3 and 3 : 1 ratios. Precursor pool enrichments and fractional synthesis values were calculated with satisfactory precision and accuracy using a simple spreadsheet. This novel approach can provide a relatively rapid and easy means to measure protein turnover based on stable isotope tracers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Quasi-static and ratcheting properties of trabecular bone under uniaxial and cyclic compression.
Gao, Li-Lan; Wei, Chao-Lei; Zhang, Chun-Qiu; Gao, Hong; Yang, Nan; Dong, Li-Min
2017-08-01
The quasi-static and ratcheting properties of trabecular bone were investigated by experiments and theoretical predictions. The creep tests with different stress levels were completed and it is found that both the creep strain and creep compliance increase rapidly at first and then increase slowly as the creep time goes by. With increase of compressive stress the creep strain increases and the creep compliance decreases. The uniaxial compressive tests show that the applied stress rate makes remarkable influence on the compressive behaviors of trabecular bone. The Young's modulus of trabecular bone increases with increase of stress rate. The stress-strain hysteresis loops of trabecular bone under cyclic load change from sparse to dense with increase of number of cycles, which agrees with the change trend of ratcheting strain. The ratcheting strain rate rapidly decreases at first, and then exhibits a relatively stable and small value after 50cycles. Both the ratcheting strain and ratcheting strain rate increase with increase of stress amplitude or with decrease of stress rate. The creep model and the nonlinear viscoelastic constitutive model of trabecular bone were proposed and used to predict its creep property and rate-dependent compressive property. The results show that there are good agreements between the experimental data and predictions. Copyright © 2017 Elsevier B.V. All rights reserved.
Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asperger, R.G.
1982-08-01
A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12more » refs.)« less
Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene
2018-01-01
Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values < 0.05 were taken statistically significant. Stool and serum samples were collected from 201 dyspeptic patients and analysed. The sensitivity, specificity, positive and negative predictive values of the SD BIOLINE H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.
Young, Sean D; Daniels, Joseph; Chiu, ChingChe J; Bolan, Robert K; Flynn, Risa P; Kwok, Justin; Klausner, Jeffrey D
2014-01-01
Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.
Ogouyèmi-Hounto, A; Kinde-Gazard, D; Keke, C; Gonçalves, E; Alapini, N; Adjovi, F; Adisso, L; Bossou, C; Denon, Y V; Massougbodji, A
2013-02-01
The aim of the study was to determine the accuracy of a rapid diagnostic test (SD Bioline Malaria Ag P.f/ Pan®) and fluorescent microscopy (CyScope®) in confirming presumptive malaria diagnosis in Cotonou. Thick blood smear was used as the reference technique for comparison. Testing was conducted on persons between the ages of 6 months and 70 years at two hospitals from June to October 2010. If malaria was suspected in the sample by the nurse based on clinical findings and sent to laboratory for confirmation, one thick smear, one rapid diagnostic test and one slide for the fluorescent microscopy were performed. All tests were read in hospital laboratories involved with the quality control of thick blood smear in the parasitology laboratory of National University Hospital of Cotonou. A total of 354 patients with clinical diagnosis of malaria were included. Malaria prevalence determined by thick smear, rapid diagnostic test and fluorescent microscopy was 22.8%, 25.4%, and 25.1% respectively. The sensitivity, specificity, positive and negative predictive values compared to the thick smears were 96.3, 95.6, 86.7, and 98.9% for rapid diagnostic test; and 97.5, 96.7, 89.8, and 99.27% for fluorescent microscopy. With these performances, these tests meet acceptability standards recommended by WHO for rapid tests (sensitivity > 95%). These two methods have advantages for the confirmation of malaria diagnosis in peripheral health structures that lack the resources to conduct diagnosis confirmation by the thick blood smear.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm.
Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K
2012-03-19
Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm
2012-01-01
Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706
NASA Astrophysics Data System (ADS)
Fan, Hong; Zhu, Anfeng; Zhang, Weixia
2015-12-01
In order to meet the rapid positioning of 12315 complaints, aiming at the natural language expression of telephone complaints, a semantic retrieval framework is proposed which is based on natural language parsing and geographical names ontology reasoning. Among them, a search result ranking and recommended algorithms is proposed which is regarding both geo-name conceptual similarity and spatial geometry relation similarity. The experiments show that this method can assist the operator to quickly find location of 12,315 complaints, increased industry and commerce customer satisfaction.
Alonso, Henar; Gavín, Patricia; Hernández-Febles, Melissa; Campos-Herrero, María Isolina; Copado, Rodolfo; Cañas, Fernando; Kremer, Kristin; Caminero, José Antonio; Martín, Carlos; Samper, Sofía
2012-01-01
The development of a rapid test to identify Mycobacterium tuberculosis Beijing isolates and specifically strain GC1237, coming from a sub-Saharan country, is needed due to its alarming wide spread on Gran Canaria Island (Spain). A rapid test that detects IS6110 present between dnaA and dnaN in the Beijing strains and in a specific site for GC1237 (Rv2180c) has been developed. This test would be a useful tool in the surveillance of subsequent cases. PMID:22116140
Mobasheri, Nasrin; Karimi, Mehrdad; Hamedi, Javad
2018-06-05
New methods to determine antimicrobial susceptibility of bacterial pathogens especially the minimum inhibitory concentration (MIC) of antibiotics have great importance in pharmaceutical industry and treatment procedures. In the present study, the MIC of several antibiotics was determined against some pathogenic bacteria using macrodilution test. In order to accelerate and increase the efficiency of culture-based method to determine antimicrobial susceptibility, the possible relationship between the changes in some physico-chemical parameters including conductivity, electrical potential difference (EPD), pH and total number of test strains was investigated during the logarithmic phase of bacterial growth in presence of antibiotics. The correlation between changes in these physico-chemical parameters and growth of bacteria was statistically evaluated using linear and non-linear regression models. Finally, the calculated MIC values in new proposed method were compared with the MIC derived from macrodilution test. The results represent significant association between the changes in EPD and pH values and growth of the tested bacteria during the exponential phase of bacterial growth. It has been assumed that the proliferation of bacteria can cause the significant changes in EPD values. The MIC values in both conventional and new method were consistent to each other. In conclusion, cost and time effective antimicrobial susceptibility test can be developed based on monitoring the changes in EPD values. The new proposed strategy also can be used in high throughput screening of biocompounds for their antimicrobial activity in a relatively shorter time (6-8 h) in comparison with the conventional methods.
Low specificity of 2 tetanus rapid tests in Cambodia.
Schlumberger, M; Yvonnet, B; Lesage, G; Tep, B
2015-01-01
Rapid testing for tetanus on serum or blood allows for an immediate evaluation of individual protection against tetanus in developed countries, using a "single step" immunochromatographic technique using tetanus toxoid. The specificity of these tests, compared to the reference method for tetanus, mouse serum neutralization testing, has however never been assessed in these countries, due to the difficulty to perform serum neutralization titration in mice, because of animal testing bioethical regulations. A collection of sera from adult volunteers in Cambodia, living in rural environment, was tested for tetanus antibodies by ELISA in France, and by mouse serum neutralization in Vietnam. This allowed estimating the sensitivity and specificity of 2 rapid tetanus tests, available on the market: TQS™ and Tetanotop™. The sensitivity of these tests was adequate, compared to mice serum neutralization test, for a test threshold of 0.01 IU/mL, (100% for TQS™, 91% for Tetanotop™), but their specificity was very low (1% for TQS™ and 13% for Tetanotop™). The results prove that these rapid tests for the assessment of individual protection against tetanus should not be used in the adult rural Cambodian population. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Measurement of the Robot Motor Capability of a Robot Motor System: A Fitts's-Law-Inspired Approach
Lin, Hsien-I; George Lee, C. S.
2013-01-01
Robot motor capability is a crucial factor for a robot, because it affects how accurately and rapidly a robot can perform a motion to accomplish a task constrained by spatial and temporal conditions. In this paper, we propose and derive a pseudo-index of motor performance (pIp) to characterize robot motor capability with robot kinematics, dynamics and control taken into consideration. The proposed pIp provides a quantitative measure for a robot with revolute joints, which is inspired from an index of performance in Fitts's law of human skills. Computer simulations and experiments on a PUMA 560 industrial robot were conducted to validate the proposed pIp for performing a motion accurately and rapidly. PMID:23820745
Measurement of the robot motor capability of a robot motor system: a Fitts's-law-inspired approach.
Lin, Hsien-I; Lee, C S George
2013-07-02
Robot motor capability is a crucial factor for a robot, because it affects how accurately and rapidly a robot can perform a motion to accomplish a task constrained by spatial and temporal conditions. In this paper, we propose and derive a pseudo-index of motor performance (pIp) to characterize robot motor capability with robot kinematics, dynamics and control taken into consideration. The proposed pIp provides a quantitative measure for a robot with revolute joints, which is inspired from an index of performance in Fitts's law of human skills. Computer simulations and experiments on a PUMA 560 industrial robot were conducted to validate the proposed pIp for performing a motion accurately and rapidly.
Hønge, Bl; Jespersen, S; Medina, C; Té, Ds; da Silva, Zj; Ostergaard, L; Laursen, Al; Wejse, C; Krarup, H; Erikstrup, C
2014-10-01
In the case of coinfection with HIV and hepatitis B virus (HBV) and/or hepatitis C virus (HCV), hepatic disease progression is often accelerated, with higher rates of liver cirrhosis and liver-related mortality. We aimed to evaluate the performance of the rapid tests used routinely to detect HBV surface antigen (HBsAg) and anti-HCV among HIV-infected patients in Guinea-Bissau. Blood samples from HIV-infected patients in Guinea-Bissau were stored after testing for HBsAg and anti-HCV with rapid tests. Samples were subsequently re-tested for HBsAg and anti-HCV in Denmark. Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended on the antigen and antibody concentrations, respectively. Sex, age, CD4 cell count and antiretroviral therapy status did not differ between false negative and true positive samples in either of the tests. The study is limited by a low number of anti-HCV positive samples. New diagnostic rapid tests should always be evaluated in the setting in which they will be used before implementation. © 2014 British HIV Association.
Injection molding lens metrology using software configurable optical test system
NASA Astrophysics Data System (ADS)
Zhan, Cheng; Cheng, Dewen; Wang, Shanshan; Wang, Yongtian
2016-10-01
Optical plastic lens produced by injection molding machine possesses numerous advantages of light quality, impact resistance, low cost, etc. The measuring methods in the optical shop are mainly interferometry, profile meter. However, these instruments are not only expensive, but also difficult to alignment. The software configurable optical test system (SCOTS) is based on the geometry of the fringe refection and phase measuring deflectometry method (PMD), which can be used to measure large diameter mirror, aspheric and freeform surface rapidly, robustly, and accurately. In addition to the conventional phase shifting method, we propose another data collection method called as dots matrix projection. We also use the Zernike polynomials to correct the camera distortion. This polynomials fitting mapping distortion method has not only simple operation, but also high conversion precision. We simulate this test system to measure the concave surface using CODE V and MATLAB. The simulation results show that the dots matrix projection method has high accuracy and SCOTS has important significance for on-line detection in optical shop.
Koishi, Andrea Cristine; Aoki, Mateus Nóbrega; Jorge, Taissa Ricciardi; Suzukawa, Andréia Akemi; Zanluca, Camila; Levis, Silvana; Duarte Dos Santos, Claudia Nunes
2016-07-01
Hantaviruses are etiologic agents of a zoonotic disease transmitted mainly from wild rodents to humans, causing Hemorrhagic Fever with Renal Syndrome in Eurasia and the Hantavirus Cardiopulmonary Syndrome in the Americas (HCPS), reaching a lethality rate of 40% in Brazil. Hantavirus diagnostic and seroprevalence are often based on the presence of IgM and IgG antibodies against the virus. Here we propose a rapid test assay able to identify hantavirus antibodies with sensibility and specificity similar to ELISA assays. We analyzed five groups of samples, including healthy human population and small mammals of endemic areas, suspected cases of HCPS, patients with non-related infections and a serum panel from a different geographical region. The test presented good rates of sensibility (87-100%) and specificity (97-100%) for all groups, being a promising tool suitable for both rodent and human hantavirus epidemiological surveys. Copyright © 2016 Elsevier Inc. All rights reserved.
MEMS Deformable Mirror Technology Development for Space-Based Exoplanet Detection
NASA Astrophysics Data System (ADS)
Bierden, Paul; Cornelissen, S.; Ryan, P.
2014-01-01
In the search for earth-like extrasolar planets that has become an important objective for NASA, a critical technology development requirement is to advance deformable mirror (DM) technology. High-actuator-count DMs are critical components for nearly all proposed coronagraph instrument concepts. The science case for exoplanet imaging is strong, and rapid recent advances in test beds with DMs made using microelectromechanical system (MEMS) technology have motivated a number of compelling mission concepts that set technical specifications for their use as wavefront controllers. This research will advance the technology readiness of the MEMS DMs components that are currently at the forefront of the field, and the project will be led by the manufacturer of those components, Boston Micromachines Corporation (BMC). The project aims to demonstrate basic functionality and performance of this key component in critical test environments and in simulated operational environments, while establishing model-based predictions of its performance relative to launch and space environments. Presented will be the current status of the project with modeling and initial test results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D. C.; Gu, X.; Haldenman, S.
The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of themore » standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.« less
Theory and practice of conventional adventitious virus testing.
Gregersen, Jens-Peter
2011-01-01
CONFERENCE PROCEEDING Proceedings of the PDA/FDA Adventitious Viruses in Biologics: Detection and Mitigation Strategies Workshop in Bethesda, MD, USA; December 1-3, 2010 Guest Editors: Arifa Khan (Bethesda, MD), Patricia Hughes (Bethesda, MD) and Michael Wiebe (San Francisco, CA) For decades conventional tests in cell cultures and in laboratory animals have served as standard methods for broad-spectrum screening for adventitious viruses. New virus detection methods based on molecular biology have broadened and improved our knowledge about potential contaminating viruses and about the suitability of the conventional test methods. This paper summarizes and discusses practical aspects of conventional test schemes, such as detectability of various viruses, questionable or false-positive results, animal numbers needed, time and cost of testing, and applicability for rapidly changing starting materials. Strategies to improve the virus safety of biological medicinal products are proposed. The strategies should be based upon a flexible application of existing and new methods along with a scientifically based risk assessment. However, testing alone does not guarantee the absence of adventitious agents and must be accompanied by virus removing or virus inactivating process steps for critical starting materials, raw materials, and for the drug product.
Direct-to-consumer personalized genomic testing
Bloss, Cinnamon S.; Darst, Burcu F.; Topol, Eric J.; Schork, Nicholas J.
2011-01-01
Over the past 18 months, there have been notable developments in the direct-to-consumer (DTC) genomic testing arena, in particular with regard to issues surrounding governmental regulation in the USA. While commentaries continue to proliferate on this topic, actual empirical research remains relatively scant. In terms of DTC genomic testing for disease susceptibility, most of the research has centered on uptake, perceptions and attitudes toward testing among health care professionals and consumers. Only a few available studies have examined actual behavioral response among consumers, and we are not aware of any studies that have examined response to DTC genetic testing for ancestry or for drug response. We propose that further research in this area is desperately needed, despite challenges in designing appropriate studies given the rapid pace at which the field is evolving. Ultimately, DTC genomic testing for common markers and conditions is only a precursor to the eventual cost-effectiveness and wide availability of whole genome sequencing of individuals, although it remains unclear whether DTC genomic information will still be attainable. Either way, however, current knowledge needs to be extended and enhanced with respect to the delivery, impact and use of increasingly accurate and comprehensive individualized genomic data. PMID:21828075
Phommasone, Koukeo; Althaus, Thomas; Souvanthong, Phonesavanh; Phakhounthong, Khansoudaphone; Soyvienvong, Laxoy; Malapheth, Phatthaphone; Mayxay, Mayfong; Pavlicek, Rebecca L; Paris, Daniel H; Dance, David; Newton, Paul; Lubell, Yoel
2016-02-04
C-Reactive Protein (CRP) has been shown to be an accurate biomarker for discriminating bacterial from viral infections in febrile patients in Southeast Asia. Here we investigate the accuracy of existing rapid qualitative and semi-quantitative tests as compared with a quantitative reference test to assess their potential for use in remote tropical settings. Blood samples were obtained from consecutive patients recruited to a prospective fever study at three sites in rural Laos. At each site, one of three rapid qualitative or semi-quantitative tests was performed, as well as a corresponding quantitative NycoCard Reader II as a reference test. We estimate the sensitivity and specificity of the three tests against a threshold of 10 mg/L and kappa values for the agreement of the two semi-quantitative tests with the results of the reference test. All three tests showed high sensitivity, specificity and kappa values as compared with the NycoCard Reader II. With a threshold of 10 mg/L the sensitivity of the tests ranged from 87-98 % and the specificity from 91-98 %. The weighted kappa values for the semi-quantitative tests were 0.7 and 0.8. The use of CRP rapid tests could offer an inexpensive and effective approach to improve the targeting of antibiotics in remote settings where health facilities are basic and laboratories are absent. This study demonstrates that accurate CRP rapid tests are commercially available; evaluations of their clinical impact and cost-effectiveness at point of care is warranted.
Performance of HIV Rapid Tests Among Breastfeeding, Malawian Infants.
Smith, Emily R; Sheahan, Anna D; Heyderman, Robert S; Miller, William C; Wheeler, Stephanie; Hudgens, Michael; Nelson, Julie A E; Dube, Queen; Van Rie, Annelies
2017-04-01
Timely, accurate and affordable testing algorithms at point-of-care are critical for early infant HIV diagnosis and initiation of antiretroviral therapy in the postpartum period. We aimed to assess the utility of HIV rapid tests for young, breast-fed HIV-exposed infants in resource limited, high HIV burden settings. We collected data on the performance of 2 commonly used rapid tests (Determine and Unigold) in Malawi between 2008 and 2012 or at the University of North Carolina between 2014 and 2015. For each 3-month interval between ages 3 and 18 months, we calculated the sensitivity, specificity, positive and negative predictive values of each test compared with the HIV DNA/RNA PCR gold standard. We also assessed the utility of each rapid test to diagnose incident HIV infection during the breastfeeding period. Among 121 HIV-exposed infants who were negative at age 6 weeks, 21 (17.2%) became infected by 18 months. At 3 months of age, both rapid tests had minimal clinical value with specificity values of 7.0% [95% confidence interval (CI): 2.3-15.7] for Determine and 19.4% (95% CI: 11.1-30.5) for Unigold. Starting at age 6 and 9 months, the Unigold test could be used as a screening tool in the follow-up of HIV-exposed infants with specificity values of 83.7% (95% CI: 74.4-89.9) and 97.7% (95% CI: 94.6-99.7), respectively. Starting at age 12 months, the type of test became less important as both tests performed well in identifying HIV-free children, although both tests failed to detect some incident HIV infections. Updated guidelines for the use of rapid tests in young HIV-exposed children that explicitly take type of test and infant age into account are urgently needed to ensure optimal care for the 1.5 million HIV-exposed infants born annually.
Causal pathways linking Farm to School to childhood obesity prevention.
Joshi, Anupama; Ratcliffe, Michelle M
2012-08-01
Farm to School programs are rapidly gaining attention as a potential strategy for preventing childhood obesity; however, the causal linkages between Farm to School activities and health outcomes are not well documented. To capitalize on the increased interest in and momentum for Farm to School, researchers and practitioners need to move from developing and implementing evidence informed programs and policies to ones that are evidence-based. The purpose of this article is to outline a framework for facilitating an evidence base for Farm to School programs and policies through a systematic and coordinated approach. Employing the concepts of causal pathways, the authors introduce a proposed framework for organizing and systematically testing out multiple hypotheses (or potential causal links) for how, why, and under what conditions Farm to School Inputs and Activities may result in what Outputs, Effects, and Impacts. Using the causal pathways framework may help develop and test competing hypotheses, identify multicausality, strength, and interactions of causes, and discern the difference between catalysts and causes. In this article, we introduce causal pathways, present menus of potential independent and dependent variables from which to create and test causal pathways linking Farm to School interventions and their role in preventing childhood obesity, discuss their applicability to Farm to School research and practice, and outline proposed next steps for developing a coordinated research framework for Farm to School programs.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-25
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Notice of Availability of a Record of... Airport (OAK), Oakland, Alameda County, CA AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... public that it has issued a ROD for the proposed construction and operation of the proposed BART...
[Dropout Prevention Program. Request for Proposal #2.
ERIC Educational Resources Information Center
Texarkana School District 7, AR.
This document provides the necessary instructions and forms for submission of a rapid learning center performance contract proposal as part of a 4-year dropout prevention program. Contract performance proposals are to embody mathematics and/or reading, and to involve students enrolled in grades 7-12 who are two or more grade levels deficient in…
Maddox, Brandy L Peterson; Wright, Shauntā S; Namadingo, Hazel; Bowen, Virginia B; Chipungu, Geoffrey A; Kamb, Mary L
2017-12-01
The WHO recommends pregnant women receive both HIV and syphilis testing at their first antenatal care visit, as untreated maternal infections can lead to severe, adverse pregnancy outcomes. One strategy for increasing testing for both HIV and syphilis is the use of point-of-care (rapid) diagnostic tests that are simple, proven effective and inexpensive. In Malawi, pregnant women routinely receive HIV testing, but only 10% are tested for syphilis at their first antenatal care visit. This evaluation explores stakeholder perceptions of a novel, dual HIV/syphilis rapid diagnostic test and potential barriers to national scale-up of the dual test in Malawi. During June and July 2015, we conducted 15 semistructured interviews with 25 healthcare workers, laboratorians, Ministry of Health leaders and partner agency representatives working in prevention of mother-to-child transmission in Malawi. We asked stakeholders about the importance of a dual rapid diagnostic test, concerns using and procuring the dual test and recommendations for national expansion. Stakeholders viewed the test favourably, citing the importance of a dual rapid test in preventing missed opportunities for syphilis diagnosis and treatment, improving infant outcomes and increasing syphilis testing coverage. Primary technical concerns were about the additional procedural steps needed to perform the test, the possibility that testers may not adhere to required waiting times before interpreting results and difficulty reading and interpreting test results. Stakeholders thought national scale-up would require demonstration of cost-savings, uniform coordination, revisions to testing guidelines and algorithms, training of testers and a reliable supply chain. Stakeholders largely support implementation of a dual HIV/syphilis rapid diagnostic test as a feasible alternative to current antenatal testing. Scale-up will require addressing perceived barriers; negotiating changes to existing algorithms and guidelines; and Ministry of Health approval and funding to support training of staff and procurement of supplies. © Article author(s) (or their employer(s) unless otherwise stated in the text of thearticle) 2017. All rights reserved. No commercial use is permitted unless otherwiseexpressly granted.
Lee, Tian-Fu; Chang, I-Pin; Lin, Tsung-Hung; Wang, Ching-Cheng
2013-06-01
The integrated EPR information system supports convenient and rapid e-medicine services. A secure and efficient authentication scheme for the integrated EPR information system provides safeguarding patients' electronic patient records (EPRs) and helps health care workers and medical personnel to rapidly making correct clinical decisions. Recently, Wu et al. proposed an efficient password-based user authentication scheme using smart cards for the integrated EPR information system, and claimed that the proposed scheme could resist various malicious attacks. However, their scheme is still vulnerable to lost smart card and stolen verifier attacks. This investigation discusses these weaknesses and proposes a secure and efficient authentication scheme for the integrated EPR information system as alternative. Compared with related approaches, the proposed scheme not only retains a lower computational cost and does not require verifier tables for storing users' secrets, but also solves the security problems in previous schemes and withstands possible attacks.
Diagnosis of Helicobacter pylori: What should be the gold standard?
Patel, Saurabh Kumar; Pratap, Chandra Bhan; Jain, Ashok Kumar; Gulati, Anil Kumar; Nath, Gopal
2014-01-01
Since the discovery of Helicobacter pylori (H. pylori) in 1983, numerous detection methods for the presence of the bacterium have been developed. Each one of them has been associated with advantages and disadvantages. Noninvasive tests such as serology, 13C urea breath test (UBT) and stool antigen tests are usually preferred by the clinicians. Serology has its own limitation especially in endemic areas while 13C UBT is technically very demanding. The stool antigen detection method, although specific, is usually associated with poor sensitivity. The 13C UBT is believed to be specific, but with present revelation of the fact that stomach is colonized by many other urease producing bacteria makes it questionable. Histology, culture, rapid urease test and polymerase chain reaction (PCR) are the tests which are carried out on antral biopsies collected by invasive means. Histology has been proposed to be very sensitive and specific but the question is how by simply looking the morphology of the bacteria in the microscope, one can claim that the curved bacterium is exclusively H. pylori. Rapid urease test (RUT), the doctor’s test, is also challenged because the presence of other urease producing bacteria in the stomach cannot be denied. Moreover, RUT has been reported with poor sensitivity specially, when density of the bacterium is low. Isolation of H. pylori is essential to investigate its growth requirements, antibiotic susceptibility testing, studying virulence factor to develop vaccine and many more explorations. It has also got several disadvantages i.e., special condition for transporting, media, incubation and few days waiting for the colonies to appear, apart from the speed essentially needed to process the specimens. Till date, majority of the microbiological laboratories in the world are not equipped and trained to isolate such fastidious bacterium. The option left is PCR methods to detect H. pylori’s DNA in gastric mucosa, gastric juice, saliva, dental plaques and environmental specimens. There are speculations for false positivity due to detection of non-pylori Helicobacters due to genetic sharing; and false negativity due to low bacterial counts and presence of PCR inhibitors. However, specimen collection, transportation and processing do not require speed and special conditions. PCR based diagnosis may be considered as gold standard by designing primers extremely specific to H. pylori and targeting at least more than one conserved genes. Similarly specificity of PCR may be improved by use of internal Primers. Further, nested PCR will take care of false negatives by countering the effect of PCR inhibitors and low bacterial counts. Therefore, nested PCR based methods if performed properly, may be proposed as gold standard test. PMID:25278682
Mikhail, Amy; Mayan, Ismail; Cundill, Bonnie; Anwar, Mohammed; Bakhtash, Sayed Habib; Mohammed, Nader; Rahman, Habib; Zekria, Rohullah; Whitty, Christopher J M; Rowland, Mark
2014-01-01
Objective To assess the impact of rapid diagnostic tests on the diagnostic accuracy and treatment of malaria and non-severe fever in an Asian setting. Design Patient randomised trial in primary level clinics. Setting Two areas of Afghanistan where Plasmodium vivax and Plasmodium falciparum are endemic; one area with moderate transmission (eastern region) and one with low transmission (northern region). Participants 5794 patients of all ages with suspected malaria enrolled by 80 clinicians in 22 clinics. Interventions Malaria rapid diagnostic tests were compared with clinical diagnosis where no parasite diagnostic test was available, longer established field microscopy, and recently introduced microscopy. Main outcome measures Proportion of patients appropriately treated with an antimalarial, defined as patients with P vivax who received chloroquine, patients with P falciparum who received artemisinin based combination therapy, and patients with no malaria parasites who did not receive an antimalarial. Secondary outcomes included diagnostic test accuracy and the proportion of patients negative for malaria who received antibiotics and antimalarials. Results In the low transmission area, comparing rapid diagnostic tests with clinical diagnosis, 65% (212/325) versus 12% (40/321) of febrile patients were appropriately treated for malaria (adjusted odds ratio 92.7, 95% confidence interval 12.4 to 694.1, P<0.001). The proportion of patients who were negative for malaria and received an antibiotic was 57% (185/325) in the rapid diagnostic test arm compared with 14% (46/321) in the clinical diagnosis arm (16.9, 3.8 to 75.4, P<0.001). In the comparison of rapid diagnostic test with microscopy in the moderate transmission area, 83.6% (1696/2028) versus 76.3% (1512/1983) of patients were appropriately treated for malaria (1.70, 1.30 to 2.23, P<0.001). A higher proportion of P falciparum cases received appropriate treatment with artemisinin based combination therapy when malaria was diagnosed by rapid diagnostic test (82%, 58/71 v 32%, 24/76; 9.2, 3.88 to 21.66, P<0.001). Conclusions In South and central Asian regions of low to moderate malaria transmission where clinics lack capacity for diagnosis with rapid diagnostic tests or microscopy, the introduction of the tests should be considered to improve clinical care, reduce the overuse of antimalarials, and improve disease surveillance. PMID:24948695
Oxidation of SiC/BN/SiC Composites in Reduced Oxygen Partial Pressures
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.; Boyd, Meredith
2010-01-01
SiC fiber-reinforced SiC composites with a BN interphase are proposed for use as leading edge structures of hypersonic vehicles. The durability of these materials under hypersonic flight conditions is therefore of interest. Thermogravimetric analysis was used to characterize the oxidation kinetics of both the constituent fibers and composite coupons at four temperatures: 816, 1149, 1343, and 1538 C (1500, 2100, 2450, and 2800 F) and in oxygen partial pressures between 5% and 0.1% (balance argon) at 1 atm total pressure. One edge of the coupons was ground off so the effects of oxygen ingress into the composite could be monitored by post-test SEM and EDS. Additional characterization of the oxidation products was conducted by XPS and TOF-SIMS. Under most conditions, the BN oxidized rapidly, leading to the formation of borosilicate glass. Rapid initial oxidation followed by volatilization of boria lead to protective oxide formation and further oxidation was slow. At 1538C in 5% oxygen, both the fibers and coupons exhibited borosilicate glass formation and bubbling. At 1538C in 0.1% oxygen, active oxidation of both the fibers and the composites was observed leading to rapid SiC degradation. BN oxidation at 1538C in 0.1% oxygen was not significant.
Wei, Shoutai; Hu, Xiaolei; Liu, Hualong; Wang, Qiang; He, Chiyang
2015-08-30
A novel molecularly imprinted polymer (MIP)-coated magnetic TiO2 nanocomposite was prepared, using methyl orange (MO) as the dummy template and pyrrole as functional monomer, for degradation of Congo red (CR). The nanocomposite was characterized by Fourier transform infrared spectroscopy, thermo-gravimetric analysis, X-ray diffraction, transmission electron microscopy, and vibrating sample magnetometer. The imprinting efficiency of the imprinted nanoparticles was investigated by static binding test, and their degradation ability toward CR was also studied. Moreover, the effects of pH, temperature, dissolved oxygen and oscillation rate on degradation rate of CR were investigated. Results showed that the imprinted nanocomposite had higher adsorption ability for MO compared with the non-imprinted one. Moreover, it could degrade CR rapidly in dark at room temperature and atmospheric pressure and could be recycled easily by a magnet with a good reusability. A degradation mechanism was proposed according to LC-MS analysis of degradation products of CR. The new imprinted nanoparticles showed high catalytic activity at ambient conditions without light illumination and additional chemicals, and therefore, it can be potentially applied to the rapid, "green" and low-cost degradation of CR in industrial printing and dyeing wastewater. Copyright © 2015 Elsevier B.V. All rights reserved.
A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.
Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying
2014-08-15
Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.
Monteiro, Sandra; Norman, Geoff; Sherbino, Jonathan
2018-06-01
There is general consensus that clinical reasoning involves 2 stages: a rapid stage where 1 or more diagnostic hypotheses are advanced and a slower stage where these hypotheses are tested or confirmed. The rapid hypothesis generation stage is considered inaccessible for analysis or observation. Consequently, recent research on clinical reasoning has focused specifically on improving the accuracy of the slower, hypothesis confirmation stage. Three perspectives have developed in this line of research, and each proposes different error reduction strategies for clinical reasoning. This paper considers these 3 perspectives and examines the underlying assumptions. Additionally, this paper reviews the evidence, or lack of, behind each class of error reduction strategies. The first perspective takes an epidemiological stance, appealing to the benefits of incorporating population data and evidence-based medicine in every day clinical reasoning. The second builds on the heuristic and bias research programme, appealing to a special class of dual process reasoning models that theorizes a rapid error prone cognitive process for problem solving with a slower more logical cognitive process capable of correcting those errors. Finally, the third perspective borrows from an exemplar model of categorization that explicitly relates clinical knowledge and experience to diagnostic accuracy. © 2018 John Wiley & Sons, Ltd.
Pinsky, Benjamin A.; Samson, Divinia; Ghafghaichi, Laleh; Baron, Ellen J.; Banaei, Niaz
2009-01-01
Staphylococcus lugdunensis is an aggressive, virulent member of the coagulase-negative staphylococci (CoNS) that is responsible for severe, rapidly progressive skin and soft tissue infections and native valve endocarditis. To facilitate prompt identification and appropriate therapy, we describe here a rapid and robust multiplex real-time PCR assay that is able to definitively distinguish S. lugdunensis from other staphylococci. Using melting curve analysis, the assay also identifies Staphylococcus aureus and CoNS other than S. lugdunensis and determines MecA-dependent resistance to methicillin (meticillin). When applied to a panel of well-characterized staphylococcal reference strains, as well as 165 clinical isolates previously identified by conventional methods, the assay was both sensitive and specific for S. lugdunensis, correctly identifying the reference strain and all 47 S. lugdunensis isolates without inappropriate amplification of other staphylococci. Furthermore, rapid biochemical identification using the WEE-TAB system to detect ornithine decarboxylase activity was found to be unsuitable as an alternative to PCR identification, displaying just 31% sensitivity and 77% specificity when tested on a subset (90 isolates) of the clinical strains. We therefore propose that this simple, accurate PCR approach will allow for the routine and timely identification of S. lugdunensis in the clinical microbiology laboratory. PMID:19741081
Rapid tests for the diagnosis of visceral leishmaniasis in patients with suspected disease
Boelaert, Marleen; Verdonck, Kristien; Menten, Joris; Sunyoto, Temmy; van Griensven, Johan; Chappuis, Francois; Rijal, Suman
2014-01-01
Background The diagnosis of visceral leishmaniasis (VL) in patients with fever and a large spleen relies on showing Leishmania parasites in tissue samples and on serological tests. Parasitological techniques are invasive, require sophisticated laboratories, consume time, or lack accuracy. Recently, rapid diagnostic tests that are easy to perform have become available. Objectives To determine the diagnostic accuracy of rapid tests for diagnosing VL in patients with suspected disease presenting at health services in endemic areas. Search methods We searched MEDLINE, EMBASE, LILACS, CIDG SR, CENTRAL, SCI-expanded, Medion, Arif, CCT, and the WHO trials register on 3 December 2013, without applying language or date limits. Selection criteria This review includes original, phase III, diagnostic accuracy studies of rapid tests in patients clinically suspected to have VL. As reference standards, we accepted: (1) direct smear or culture of spleen aspirate; (2) composite reference standard based on one or more of the following: parasitology, serology, or response to treatment; and (3) latent class analysis. Data collection and analysis Two review authors independently extracted data and assessed quality of included studies using the QUADAS-2 tool. Discrepancies were resolved by a third author. We carried out a meta-analysis to estimate sensitivity and specificity of rapid tests, using a bivariate normal model with a complementary log-log link function. We analysed each index test separately. As possible sources of heterogeneity, we explored: geographical area, commercial brand of index test, type of reference standard, disease prevalence, study size, and risk of bias (QUADAS-2). We also undertook a sensitivity analysis to assess the influence of imperfect reference standards. Main results Twenty-four studies containing information about five index tests (rK39 immunochromatographic test (ICT), KAtex latex agglutination test in urine, FAST agglutination test, rK26 ICT, and rKE16 ICT) recruiting 4271 participants (2605 with VL) were included. We carried out a meta-analysis for the rK39 ICT (including 18 studies; 3622 participants) and the latex agglutination test (six studies; 1374 participants). The results showed considerable heterogeneity. For the rK39 ICT, the overall sensitivity was 91.9% (95% confidence interval (95% CI) 84.8 to 96.5) and the specificity 92.4% (95% CI 85.6 to 96.8). The sensitivity was lower in East Africa (85.3%; 95% CI 74.5 to 93.2) than in the Indian subcontinent (97.0%; 95% CI 90.0 to 99.5). For the latex agglutination test, overall sensitivity was 63.6% (95% CI 40.9 to 85.6) and specificity 92.9% (95% CI 76.7 to 99.2). Authors' conclusions The rK39 ICT shows high sensitivity and specificity for the diagnosis of visceral leishmaniasis in patients with febrile splenomegaly and no previous history of the disease, but the sensitivity is notably lower in east Africa than in the Indian subcontinent. Other rapid tests lack accuracy, validation, or both. PLAIN LANGUAGE SUMMARY Rapid diagnostic tests for visceral leishmaniasis Visceral leishmaniasis (or kala-azar) is caused by a parasite, results in fever, a large spleen and other health problems, occuring in India, Bangladesh and Nepal, east Africa, the Mediterranean region and Brazil. Without treatment people die, and proper treatment can result in cure, so diagnosis is important. Many of the tests that are used to determine if a person has visceral leishmaniasis are complicated, costly, painful and sometimes dangerous for the patients. Now rapid diagnostic tests that are safe and easy to perform are available. This Cochrane review describes how accurate these rapid diagnostic tests are for diagnosing visceral leishmaniasis. We summarize those studies that evaluated the rapid tests in people who, according to their physicians, could have the disease. We only included studies in which the researchers had used established methods to distinguish the people with visceral leishmaniasis from those who did not have the disease. We found 24 studies, which contained information about five different rapid tests. A total of 4271 people participated in these studies. One of the rapid tests (called the rK39 immunochromatographic test) gave correct, positive results in 92% of the people with visceral leishmaniasis and it gave correct, negative results in 92% of the people who did not have the disease. This test worked better in India and Nepal than in east Africa. In India and Nepal, it gave correct, positive results in 97% of the people with the disease. In east Africa, it gave correct, positive results in only 85% of the people with the disease. A second rapid test (called latex agglutination test) gave correct, positive results in 64% of the people with the disease and it gave correct, negative results in 93% of the people without the disease. For the other rapid tests evaluated, there are too few studies to know how accurate they are. PMID:24947503
Leaché, Adam D; Banbury, Barbara L; Linkem, Charles W; de Oca, Adrián Nieto-Montes
2016-03-22
Resolving the short phylogenetic branches that result from rapid evolutionary diversification often requires large numbers of loci. We collected targeted sequence capture data from 585 nuclear loci (541 ultraconserved elements and 44 protein-coding genes) to estimate the phylogenetic relationships among iguanian lizards in the North American genus Sceloporus. We tested for diversification rate shifts to determine if rapid radiation in the genus is correlated with chromosomal evolution. The phylogenomic trees that we obtained for Sceloporus using concatenation and coalescent-based species tree inference provide strong support for the monophyly and interrelationships among nearly all major groups. The diversification analysis supported one rate shift on the Sceloporus phylogeny approximately 20-25 million years ago that is associated with the doubling of the speciation rate from 0.06 species/million years (Ma) to 0.15 species/Ma. The posterior probability for this rate shift occurring on the branch leading to the Sceloporus species groups exhibiting increased chromosomal diversity is high (posterior probability = 0.997). Despite high levels of gene tree discordance, we were able to estimate a phylogenomic tree for Sceloporus that solves some of the taxonomic problems caused by previous analyses of fewer loci. The taxonomic changes that we propose using this new phylogenomic tree help clarify the number and composition of the major species groups in the genus. Our study provides new evidence for a putative link between chromosomal evolution and the rapid divergence and radiation of Sceloporus across North America.
Gaikwad, Seema; Sawant, Sandhya S.; Shastri, Jayanthi S.
2017-01-01
INTRODUCTION: Early diagnosis of dengue is important for appropriate clinical management and vector control. Different serological tests based on the principle of immunochromatography and enzyme-linked immunosorbent assay (ELISA) are commonly used for detection of antigen and antibodies of dengue virus. The performance of these tests depends on the sensitivity and specificity. Hence, the study was undertaken to compare nonstructural protein-1 (NS1) antigen detection by rapid and ELISA with real-time polymerase chain reaction (RT-PCR) for diagnosis of dengue. MATERIALS AND METHODS: Prospective laboratory study was carried out on sera samples (n = 200) from clinically suspected cases of dengue. The sera samples were subjected for NS1 antigen detection test by rapid test, NS1 ELISA, and RT-PCR. The results of rapid and ELISA tests were compared with real Time PCR. RESULTS: The sensitivity, specificity, positive, and negative predictive value of rapid dengue NS1 antigen test were 81.5%, 66.7%, 78.2%, and 71.1%, respectively whereas that of NS1 ELISA were 89.9%, 100%, 100%, and 94%, respectively. Concordance of Rapid NS1 and NS1 ELISA with PCR was 75.5% and 94%. DISCUSSION AND CONCLUSION: NS1 antigen ELISA can be implemented in diagnostic laboratories for diagnosis of dengue in the acute phase of illness. The test also has great potential value for use in epidemic situations, as it could facilitate the early screening of patients and limit disease expansion. PMID:28706387
Rapid Model Fabrication and Testing for Aerospace Vehicles
NASA Technical Reports Server (NTRS)
Buck, Gregory M.
2000-01-01
Advanced methods for rapid fabrication and instrumentation of hypersonic wind tunnel models are being developed and evaluated at NASA Langley Research Center. Rapid aeroheating model fabrication and measurement techniques using investment casting of ceramic test models and thermographic phosphors are reviewed. More accurate model casting techniques for fabrication of benchmark metal and ceramic test models are being developed using a combination of rapid prototype patterns and investment casting. White light optical scanning is used for coordinate measurements to evaluate the fabrication process and verify model accuracy to +/- 0.002 inches. Higher-temperature (<210C) luminescent coatings are also being developed for simultaneous pressure and temperature mapping, providing global pressure as well as global aeroheating measurements. Together these techniques will provide a more rapid and complete experimental aerodynamic and aerothermodynamic database for future aerospace vehicles.
USDA-ARS?s Scientific Manuscript database
Strip lateral flow assays, similar to a home pregnancy test, are used widely in food safety applications to provide rapid and accurate tests for the presence of specific foodborne pathogens or other contaminants. Though these tests are very rapid, they are not very sensitive, are not quantitative, a...
Sand, Christina; Englert, Theresa; Egberink, Herman; Lutz, Hans; Hartmann, Katrin
2010-06-01
Many in-house tests for the diagnosis of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infection are licensed for use in veterinary practice. A new test with unknown performance has recently appeared on the market. The aims of this study were to define the efficacy of a new in-clinic test system, the Anigen Rapid FIV Ab/FeLV Ag Test, and to compare it with the current leading in-clinic test, the SNAP Kombi Plus FeLV Antigen/FIB Antibody Test. Three-hundred serum samples from randomly selected healthy and diseased cats presented to the Clinic of Small Animal Medicine at Ludwig Maximilian University were tested using both the Anigen Rapid Test and the SNAP Kombi Plus Test. Diagnostic sensitivity, specificity, and positive and negative predictive values were calculated for both tests using Western blot as the gold standard for verification of FIV infection and PCR as the gold standard for FeLV infection. The presence of antibodies against FIV was confirmed by Western blot in 9/300 samples (prevalence 3%). FeLV DNA was detected by PCR in 15/300 samples (prevalence 5%). For FIV infection the Anigen Rapid Test had a sensitivity of 88.9%, specificity of 99.7%, positive predictive value of 88.9%, and negative predictive value of 99.7%. For FeLV infection, the Anigen Rapid Test had a sensitivity of 40.0%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 96.9%. Diagnostic accuracy was similar to that of the SNAP Kombi Plus Test. The new Anigen Rapid FIV Ab/FeLV Ag Test performed very well and can be recommended for use in veterinary practice.
Schackman, Bruce R; Metsch, Lisa R; Colfax, Grant N; Leff, Jared A; Wong, Angela; Scott, Callie A; Feaster, Daniel J; Gooden, Lauren; Matheson, Tim; Haynes, Louise F; Paltiel, A David; Walensky, Rochelle P
2013-02-01
The President's National HIV/AIDS Strategy calls for coupling HIV screening and prevention services with substance abuse treatment programs. Fewer than half of US community-based substance abuse treatment programs make HIV testing available on-site or through referral. We measured the cost-effectiveness of three HIV testing strategies evaluated in a randomized trial conducted in 12 community-based substance abuse treatment programs in 2009: off-site testing referral, on-site rapid testing with information only, on-site rapid testing with risk-reduction counseling. Data from the trial included patient demographics, prior testing history, test acceptance and receipt of results, undiagnosed HIV prevalence (0.4%) and program costs. The Cost-Effectiveness of Preventing AIDS Complications (CEPAC) computer simulation model was used to project life expectancy, lifetime costs, and quality-adjusted life years (QALYs) for HIV-infected individuals. Incremental cost-effectiveness ratios (2009 US $/QALY) were calculated after adding costs of testing HIV-uninfected individuals; costs and QALYs were discounted at 3% annually. Referral for off-site testing is less efficient (dominated) compared to offering on-site testing with information only. The cost-effectiveness ratio for on-site testing with information is $60,300/QALY in the base case, or $76,300/QALY with 0.1% undiagnosed HIV prevalence. HIV risk-reduction counseling costs $36 per person more without additional benefit. A strategy of on-site rapid HIV testing offer with information only in substance abuse treatment programs increases life expectancy at a cost-effectiveness ratio <$100,000/QALY. Policymakers and substance abuse treatment leaders should seek funding to implement on-site rapid HIV testing in substance abuse treatment programs for those not recently tested. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Schackman, Bruce R.; Metsch, Lisa R.; Colfax, Grant N.; Leff, Jared A.; Wong, Angela; Scott, Callie A.; Feaster, Daniel J.; Gooden, Lauren; Matheson, Tim; Haynes, Louise F.; Paltiel, A. David; Walensky, Rochelle P.
2012-01-01
BACKGROUND The President’s National HIV/AIDS Strategy calls for coupling HIV screening and prevention services with substance abuse treatment programs. Fewer than half of US community-based substance abuse treatment programs make HIV testing available on-site or through referral. METHODS We measured the cost-effectiveness of three HIV testing strategies evaluated in a randomized trial conducted in 12 community-based substance abuse treatment programs in 2009: off-site testing referral, on-site rapid testing with information only, on-site rapid testing with risk reduction counseling. Data from the trial included patient demographics, prior testing history, test acceptance and receipt of results, undiagnosed HIV prevalence (0.4%) and program costs. The Cost Effectiveness of Preventing AIDS Complications (CEPAC) computer simulation model was used to project life expectancy, lifetime costs, and quality-adjusted life years (QALYs) for HIV-infected individuals. Incremental cost-effectiveness ratios (2009 US $/QALY) were calculated after adding costs of testing HIV-uninfected individuals; costs and QALYs were discounted at 3% annually. RESULTS Referral for off-site testing is less efficient (dominated) compared to offering on-site testing with information only. The cost-effectiveness ratio for on-site testing with information is $60,300/QALY in the base case, or $76,300/QALY with 0.1% undiagnosed HIV prevalence. HIV risk-reduction counseling costs $36 per person more without additional benefit. CONCLUSIONS A strategy of on-site rapid HIV testing offer with information only in substance abuse treatment programs increases life expectancy at a cost-effectiveness ratio <$100,000/QALY. Policymakers and substance abuse treatment leaders should seek funding to implement on-site rapid HIV testing in substance abuse treatment programs for those not recently tested. PMID:22971593
NASA Technical Reports Server (NTRS)
Cambon, C.; Coleman, G. N.; Mansour, N. N.
1992-01-01
The effect of rapid mean compression on compressible turbulence at a range of turbulent Mach numbers is investigated. Rapid distortion theory (RDT) and direct numerical simulation results for the case of axial (one-dimensional) compression are used to illustrate the existence of two distinct rapid compression regimes. These regimes are set by the relationships between the timescales of the mean distortion, the turbulence, and the speed of sound. A general RDT formulation is developed and is proposed as a means of improving turbulence models for compressible flows.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D.; Wohlgemuth, J.; Gu, X.
2013-11-01
The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of themore » standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.« less
DOT National Transportation Integrated Search
2014-07-01
The purpose of this project is to provide DOTD match funding for the proposed research. : This project is associated with the LTRC/Southern partnership with Research on Concrete : Applications for Sustainable Transportation (RE-CAST) Rapid Pavement C...
Rapid detection of EBOLA VP40 in microchip immunofiltration assay
NASA Astrophysics Data System (ADS)
Miethe, Peter; Gary, Dominik; Hlawatsch, Nadine; Gad, Anne-Marie
2015-05-01
In the spring of 2014, the Ebola virus (EBOV) strain Zaire caused a dramatic outbreak in several regions of West Africa. The RT-PCR and antigen capture diagnostic proved to be effective for detecting EBOV in blood and serum. In this paper, we present data of a rapid antigen capture test for the detection of VP40. The test was performed in a microfluidic chip for immunofiltration analysis. The chip integrates all necessary assay components. The analytical sensitivity of the rapid test was 8 ng/ml for recombinant VP40. In serum and whole blood samples spiked with virus culture material, the detection limit was 2.2 x 102 PFU/ml. The performance data of the rapid test (15 min) are comparable to that of the VP40 laboratory ELISA.
Woo, Patrick C Y; Lau, Susanna K P; Chen, Yixin; Wong, Emily Y M; Chan, Kwok-Hung; Chen, Honglin; Zhang, Libiao; Xia, Ningshao; Yuen, Kwok-Yung
2018-03-07
Recently, we developed a monoclonal antibody-based rapid nucleocapsid protein detection assay for diagnosis of MERS coronavirus (MERS-CoV) in humans and dromedary camels. In this study, we examined the usefulness of this assay to detect other lineage C betacoronaviruses closely related to MERS-CoV in bats. The rapid MERS-CoV nucleocapsid protein detection assay was tested positive in 24 (88.9%) of 27 Tylonycteris bat CoV HKU4 (Ty-BatCoV-HKU4) RNA-positive alimentary samples of Tylonycteris pachypus and 4 (19.0%) of 21 Pipistrellus bat CoV HKU5 (Pi-BatCoV-HKU5) RNA-positive alimentary samples of Pipistrellus abramus. There was significantly more Ty-BatCoV-HKU4 RNA-positive alimentary samples than Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive by the rapid MERS-CoV nucleocapsid protein detection assay (P < 0.001 by Chi-square test). The rapid assay was tested negative in all 51 alimentary samples RNA-positive for alphacoronaviruses (Rhinolophus bat CoV HKU2, Myotis bat CoV HKU6, Miniopterus bat CoV HKU8 and Hipposideros batCoV HKU10) and 32 alimentary samples positive for lineage B (SARS-related Rhinolophus bat CoV HKU3) and lineage D (Rousettus bat CoV HKU9) betacoronaviruses. No significant difference was observed between the viral loads of Ty-BatCoV-HKU4/Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive and negative by the rapid test (Mann-Witney U test). The rapid MERS-CoV nucleocapsid protein detection assay is able to rapidly detect lineage C betacoronaviruses in bats. It detected significantly more Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5 because MERS-CoV is more closely related to Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5. This assay will facilitate rapid on-site mass screening of animal samples for ancestors of MERS-CoV and tracking transmission in the related bat species.
Ren, Li; Tao, Weiwei; Zhang, Hailou; Xue, Wenda; Tang, Juanjuan; Wu, Ruyan; Xia, Baomei; Wu, Haoxing; Chen, Gang
2016-07-01
Gardenia jasminoides Ellis (GJ) is one of the five constituents of Yueju pill, a Traditional Chinese Medicine for treatment of syndromes associated with mood disorders. Recently, preclinical and clinical studies suggest that Yueju pill confers rapid antidepressant effects. GJ is identified as the constituent primary for Yueju pill's rapid antidepressant effects. GJ's antidepressant action is temporally associated with up-regulated expression of brain-derived neurotrophic factor (BDNF) in the hippocampus. The present study aimed to identify chemical fractions responsible for the rapid antidepressant efficacy of GJ and its association with BDNF signaling. Four fractions of GJ were extracted using standardized procedure. The four fractions were screened for rapid antidepressant potential, using the behavioral paradigm of forced swimming test (FST) and tail suspension test (TST) assessed at 24h post a single administration. A single dose of the putatively effective fractions was further tested in mice exposed to chronic mild stress (CMS), followed with a comprehensive behavioral testing including TST, FST, sucrose preference test (SPT), and novelty suppressed-feeding (NSF). To test the association of BDNF signaling with rapid antidepressant effects of effective factions, the expressions of BDNF and its receptor tropomyosin receptor kinase B (TrkB) in the hippocampus were assessed at different times post a single administration of effective fractions. Both petroleum ether (GJ-PE) and n-butyl alcohol fraction (GJ-BO) fractions of GJ displayed rapid antidepressant potential in the FST. In the TST, the antidepressant effects of GJ-PE lasted for a longer time than GJ-BO. Acute administration of either GJ-PE or GJ-BO significantly reversed the behavioral deficits in the tests of TST, FST, SPT and NSF in chronically stressed mice, confirming both fractions conferred rapid antidepressant efficacy. Interestingly, GJ-PE, but not GJ-BO, increased the expression of BDNF and TrkB in the hippocampus post a single administration. Two standardized fractions GJ-PE and GJ-BO exhibited comparable rapid antidepressant-like effects on the CMS mice. However, only the effects of GJ-PE was associated with BDNF signaling. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kang, Jungho; Kim, Mansik; Park, Jong Hyuk
2016-01-01
With the ICT technology making great progress in the smart home environment, the ubiquitous environment is rapidly emerging all over the world, but problems are also increasing proportionally to the rapid growth of the smart home market such as multiplatform heterogeneity and new security threats. In addition, the smart home sensors have so low computing resources that they cannot process complicated computation tasks, which is required to create a proper security environment. A service provider also faces overhead in processing data from a rapidly increasing number of sensors. This paper aimed to propose a scheme to build infrastructure in which communication entities can securely authenticate and design security channel with physically unclonable PUFs and the TTP that smart home communication entities can rely on. In addition, we analyze and evaluate the proposed scheme for security and performance and prove that it can build secure channels with low resources. Finally, we expect that the proposed scheme can be helpful for secure communication with low resources in future smart home multiplatforms. PMID:27399699
Kang, Jungho; Kim, Mansik; Park, Jong Hyuk
2016-07-05
With the ICT technology making great progress in the smart home environment, the ubiquitous environment is rapidly emerging all over the world, but problems are also increasing proportionally to the rapid growth of the smart home market such as multiplatform heterogeneity and new security threats. In addition, the smart home sensors have so low computing resources that they cannot process complicated computation tasks, which is required to create a proper security environment. A service provider also faces overhead in processing data from a rapidly increasing number of sensors. This paper aimed to propose a scheme to build infrastructure in which communication entities can securely authenticate and design security channel with physically unclonable PUFs and the TTP that smart home communication entities can rely on. In addition, we analyze and evaluate the proposed scheme for security and performance and prove that it can build secure channels with low resources. Finally, we expect that the proposed scheme can be helpful for secure communication with low resources in future smart home multiplatforms.
A recreation quality rapid assessment method for visitor capacity management
Kenneth Chilman; Stuart Schneider; Les Wadzinski
2007-01-01
A rapid assessment method for inexpensively obtaining representative samples of place-specific visitor numbers and perceptions of visit quality was tested on Niobrara National Scenic River (NSR). Similar tests have been done on national forest areas in Indiana and Illinois. The data are used in meetings focusing on visitor capacity management. The rapid assessment...
Drinking water test methods in crisis-afflicted areas: comparison of methods under field conditions.
Merle, Roswitha; Bleul, Ingo; Schulenburg, Jörg; Kreienbrock, Lothar; Klein, Günter
2011-11-01
To simplify the testing of drinking water in crisis-afflicted areas (as in Kosovo in 2007), rapid test methods were compared with the standard test. For Escherichia coli and coliform pathogens, rapid tests were made available: Colilert(®)-18, P/A test with 4-methylumbelliferyl-β-D-glucoronid, and m-Endo Broth. Biochemical differentiation was carried out by Enterotube™ II. Enterococci were determined following the standard ISO test and by means of Enterolert™. Four hundred ninety-nine water samples were tested for E. coli and coliforms using four methods. Following the standard method, 20.8% (n=104) of the samples contained E. coli, whereas the rapid tests detected between 19.6% (m-Endo Broth, 92.0% concordance) and 20.0% (concordance: 93.6% Colilert-18 and 94.8% P/A-test) positive samples. Regarding coliforms, the percentage of concordant results ranged from 98.4% (P/A-test) to 99.0% (Colilert-18). Colilert-18 and m-Endo Broth detected even more positive samples than the standard method did. Enterococci were detected in 93 of 573 samples by the standard method, but in 92 samples by Enterolert (concordance: 99.5%). Considering the high-quality equipment and time requirements of the standard method, the use of rapid tests in crisis-afflicted areas is sufficiently reliable.
Hou, Yu-Lan; Wu, Shuang; Wang, Hua; Zhao, Yong; Liao, Peng; Tian, Qing-Qing; Sun, Wen-Jian; Chen, Bo
2013-01-01
A novel rapid method for detection of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines was developed with the desorption corona beam ionization mass spectrometry (DCBI-MS) technique. The DCBI conditions including temperature and sample volume were optimized according to the resulting mass spectra intensity. Matrix effect on 9 beta2-agonists additives was not significant in the proposed rapid determination procedure. All of the 9 target molecules were detected within 1 min. Quantification was achieved based on the typical fragment ion in MS2 spectra of each analyte. The method showed good linear coefficients in the range of 1-100 mg x L(-1) for all analytes. The relative deviation values were between 14.29% and 25.13%. Ten claimed antitussive and antiasthmatic health foods and traditional Chinese patent medicines from local pharmacies were analyzed. All of them were negative with the proposed DCBI-MS method. Without tedious sample pretreatments, the developed DCBI-MS is simple, rapid and sensitive for rapid qualification and semi-quantification of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines.
Cox, Marsha E.; DiNello, Robert K.; Geisberg, Mark; Abbott, April; Roberts, Pacita L.; Hooton, Thomas M.
2015-01-01
Urinary tract infections (UTIs) are frequently encountered in clinical practice and most commonly caused by Escherichia coli and other Gram-negative uropathogens. We tested RapidBac, a rapid immunoassay for bacteriuria developed by Silver Lake Research Corporation (SLRC), compared with standard bacterial culture using 966 clean-catch urine specimens submitted to a clinical microbiology laboratory in an urban academic medical center. RapidBac was performed in accordance with instructions, providing a positive or negative result in 20 min. RapidBac identified as positive 245/285 (sensitivity 86%) samples with significant bacteriuria, defined as the presence of a Gram-negative uropathogen or Staphylococcus saprophyticus at ≥103 CFU/ml. The sensitivities for Gram-negative bacteriuria at ≥104 CFU/ml and ≥105 CFU/ml were 96% and 99%, respectively. The specificity of the test, detecting the absence of significant bacteriuria, was 94%. The sensitivity and specificity of RapidBac were similar on samples from inpatient and outpatient settings, from male and female patients, and across age groups from 18 to 89 years old, although specificity was higher in men (100%) compared with that in women (92%). The RapidBac test for bacteriuria may be effective as an aid in the point-of-care diagnosis of UTIs especially in emergency and primary care settings. PMID:26063858
NASA Astrophysics Data System (ADS)
Jiang, Hao; Lu, Jiangang
2018-05-01
Corn starch is an important material which has been traditionally used in the fields of food and chemical industry. In order to enhance the rapidness and reliability of the determination for starch content in corn, a methodology is proposed in this work, using an optimal CC-PLSR-RBFNN calibration model and near-infrared (NIR) spectroscopy. The proposed model was developed based on the optimal selection of crucial parameters and the combination of correlation coefficient method (CC), partial least squares regression (PLSR) and radial basis function neural network (RBFNN). To test the performance of the model, a standard NIR spectroscopy data set was introduced, containing spectral information and chemical reference measurements of 80 corn samples. For comparison, several other models based on the identical data set were also briefly discussed. In this process, the root mean square error of prediction (RMSEP) and coefficient of determination (Rp2) in the prediction set were used to make evaluations. As a result, the proposed model presented the best predictive performance with the smallest RMSEP (0.0497%) and the highest Rp2 (0.9968). Therefore, the proposed method combining NIR spectroscopy with the optimal CC-PLSR-RBFNN model can be helpful to determine starch content in corn.
Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units.
Cai, Qingzhong; Yang, Gongliu; Song, Ningfang; Liu, Yiliang
2016-06-22
An inertial navigation system (INS) has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10(-6)°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs) using common turntables, has a great application potential in future atomic gyro INSs.
Liu, Liangbing; Tao, Chao; Liu, XiaoJun; Deng, Mingxi; Wang, Senhua; Liu, Jun
2015-10-19
Photoacoustic tomography is a promising and rapidly developed methodology of biomedical imaging. It confronts an increasing urgent problem to reconstruct the image from weak and noisy photoacoustic signals, owing to its high benefit in extending the imaging depth and decreasing the dose of laser exposure. Based on the time-domain characteristics of photoacoustic signals, a pulse decomposition algorithm is proposed to reconstruct a photoacoustic image from signals with low signal-to-noise ratio. In this method, a photoacoustic signal is decomposed as the weighted summation of a set of pulses in the time-domain. Images are reconstructed from the weight factors, which are directly related to the optical absorption coefficient. Both simulation and experiment are conducted to test the performance of the method. Numerical simulations show that when the signal-to-noise ratio is -4 dB, the proposed method decreases the reconstruction error to about 17%, in comparison with the conventional back-projection method. Moreover, it can produce acceptable images even when the signal-to-noise ratio is decreased to -10 dB. Experiments show that, when the laser influence level is low, the proposed method achieves a relatively clean image of a hair phantom with some well preserved pattern details. The proposed method demonstrates imaging potential of photoacoustic tomography in expanding applications.