Stanton, M. Mark; Nelson, Lisa K.; Benediktsson, Hallgrimur; Hollenberg, Morley D.; Buret, Andre G.; Ceri, Howard
2013-01-01
Background. Nonbacterial prostatitis has no established etiology. We hypothesized that proteinase-activated receptor-1 (PAR1) can play a role in prostatitis. We therefore investigated the effects of PAR1 stimulation in the context of a new model of murine nonbacterial prostatitis. Methods. Using a hapten (ethanol-dinitrobenzene sulfonic acid- (DNBS-)) induced prostatitis model with both wild-type and PAR1-null mice, we examined (1) the location of PAR1 in the mouse prostate and (2) the impact of a PAR1-activating peptide (TFLLR-NH2: PAR1-TF) on ethanol-DNBS-induced inflammation. Results. Ethanol-DNBS-induced inflammation was maximal at 2 days. In the tissue, PAR1 was expressed predominantly along the apical acini of prostatic epithelium. Although PAR1-TF on its own did not cause inflammation, its coadministration with ethanol-DNBS reduced all indices of acute prostatitis. Further, PAR1-TF administration doubled the prostatic production of interleukin-10 (IL-10) compared with ethanol-DNBS treatment alone. This enhanced IL-10 was not observed in PAR1-null mice and was not caused by the reverse-sequence receptor-inactive peptide, RLLFT-NH2. Surprisingly, PAR1-TF, also diminished ethanol-DNBS-induced inflammation in PAR1-null mice. Conclusions. PAR1 is expressed in the mouse prostate and its activation by PAR1-TF elicits immunomodulatory effects during ethanol-DNBS-induced prostatitis. However, PAR1-TF also diminishes ethanol-DNBS-induced inflammation via a non-PAR1 mechanism by activating an as-yet unknown receptor. PMID:24459330
Roman, Kenny; Done, Joseph D.; Schaeffer, Anthony J.; Murphy, Stephen F.; Thumbikat, Praveen
2014-01-01
Chronic prostatitis/Chronic pelvic pain syndrome (CP/CPPS) affects up to 15% of the male population and is characterized by pelvic pain. Mast cells are implicated in the murine experimental autoimmune prostatitis (EAP) model as key to chronic pelvic pain development. The mast cell mediator tryptase-β and its cognate receptor protease-activated receptor 2 (PAR2) are involved in mediating pain in other visceral disease models. Prostatic secretions and urines from CP/CPPS patients were examined for the presence of mast cell degranulation products. Tryptase-β and PAR2 expression were examined in murine experimental autoimmune prostatitis (EAP). Pelvic pain and inflammation were assessed in the presence or absence of PAR2 expression and upon PAR2 neutralization. Tryptase-β and carboxypeptidase A3 were elevated in CP/CPPS compared to healthy volunteers. Tryptase-β was capable of inducing pelvic pain and was increased in EAP along with its receptor PAR2. PAR2 was required for the development of chronic pelvic pain in EAP. PAR2 signaling in dorsal root ganglia lead to ERK1/2 phosphorylation and calcium influx. PAR2 neutralization using antibodies attenuated chronic pelvic pain in EAP. The tryptase-PAR2 axis is an important mediator of pelvic pain in EAP and may play a role in the pathogenesis of CP/CPPS. PMID:24726923
Ramsay, Andrew J; Dong, Ying; Hunt, Melanie L; Linn, MayLa; Samaratunga, Hemamali; Clements, Judith A; Hooper, John D
2008-05-02
Kallikrein-related peptidase 4 (KLK4) is one of the 15 members of the human KLK family and a trypsin-like, prostate cancer-associated serine protease. Signaling initiated by trypsin-like serine proteases are transduced across the plasma membrane primarily by members of the protease-activated receptor (PAR) family of G protein-coupled receptors. Here we show, using Ca(2+) flux assays, that KLK4 signals via both PAR-1 and PAR-2 but not via PAR-4. Dose-response analysis over the enzyme concentration range 0.1-1000 nM indicated that KLK4-induced Ca(2+) mobilization via PAR-1 is more potent than via PAR-2, whereas KLK4 displayed greater efficacy via the latter PAR. We confirmed the specificity of KLK4 signaling via PAR-2 using in vitro protease cleavage assays and anti-phospho-ERK1/2/total ERK1/2 Western blot analysis of PAR-2-overexpressing and small interfering RNA-mediated receptor knockdown cell lines. Consistently, confocal microscopy analyses indicated that KLK4 initiates loss of PAR-2 from the cell surface and receptor internalization. Immunohistochemical analysis indicated the co-expression of agonist and PAR-2 in primary prostate cancer and bone metastases, suggesting that KLK4 signaling via this receptor will have pathological relevance. These data provide insight into KLK4-mediated cell signaling and suggest that signals induced by this enzyme via PARs may be important in prostate cancer.
Knaup, Courtney; Mavroidis, Panayiotis; Stathakis, Sotirios; Smith, Mark; Swanson, Gregory; Papanikolaou, Niko
2011-09-01
This study evaluates low dose-rate brachytherapy (LDR) prostate plans to determine the biological effect of dose degradation due to prostate volume changes. In this study, 39 patients were evaluated. Pre-implant prostate volume was determined using ultrasound. These images were used with the treatment planning system (Nucletron Spot Pro 3.1(®)) to create treatment plans using (103)Pd seeds. Following the implant, patients were imaged using CT for post-implant dosimetry. From the pre and post-implant DVHs, the biologically equivalent dose and the tumor control probability (TCP) were determined using the biologically effective uniform dose. The model used RBE = 1.75 and α/β = 2 Gy. The prostate volume changed between pre and post implant image sets ranged from -8% to 110%. TCP and the mean dose were reduced up to 21% and 56%, respectively. TCP is observed to decrease as the mean dose decreases to the prostate. The post-implant tumor dose was generally observed to decrease, compared to the planned dose. A critical uniform dose of 130 Gy was established. Below this dose, TCP begins to fall-off. It was also determined that patients with a small prostates were more likely to suffer TCP decrease. The biological effect of post operative prostate growth due to operative trauma in LDR was evaluated using the concept. The post-implant dose was lower than the planned dose due to an increase of prostate volume post-implant. A critical uniform dose of 130 Gy was determined, below which TCP begun to decline.
Nicholson, Tristan M.; Uchtmann, Kristen S.; Valdez, Conrad D.; Theberge, Ashleigh B.; Miralem, Tihomir; Ricke, William A.
2013-01-01
New therapies for two common prostate diseases, prostate cancer (PrCa) and benign prostatic hyperplasia (BPH), depend critically on experiments evaluating their hormonal regulation. Sex steroid hormones (notably androgens and estrogens) are important in PrCa and BPH; we probe their respective roles in inducing prostate growth and carcinogenesis in mice with experiments using compressed hormone pellets. Hormone and/or drug pellets are easily manufactured with a pellet press, and surgically implanted into the subcutaneous tissue of the male mouse host. We also describe a protocol for the evaluation of hormonal carcinogenesis by combining subcutaneous hormone pellet implantation with xenografting of prostate cell recombinants under the renal capsule of immunocompromised mice. Moreover, subcutaneous hormone pellet implantation, in combination with renal capsule xenografting of BPH tissue, is useful to better understand hormonal regulation of benign prostate growth, and to test new therapies targeting sex steroid hormone pathways. PMID:24022657
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riofrio, D; Luan, S; Zhou, J
Purpose: In prostate HDR brachytherapy, interstitial implants are placed manually on the fly. The aim for this research is to develop a computer algorithm to find optimal and reliable implant trajectories using minimal number of implants. Methods: Our new algorithm mainly uses these key ideas: (1) positive charged static particles are uniformly placed on the surface of prostate and critical structures such as urethra, bladder, and rectum. (2) Positive charged kinetic particles are placed at a cross-section of the prostate with an initial velocity parallel to the principal implant direction. (3) The kinetic particles move through the prostate, interacting withmore » each other, spreading out, while staying away from the prostate surface and critical structures. The initial velocity ensures that the trajectories observe the curvature constraints of typical implant procedures. (4) The finial trajectories of kinetic particles are smoothed using a third-degree polynomial regression, which become the implant trajectories. (5) The dwelling times and final dose distribution are calculated using least-distance programming. Results: (1) We experimented with previously treated cases. Our plan achieves all prescription goals while reducing the number of implants by 41%! Our plan also has less uniform target dose, which implies a higher dose is delivered to the prostate. (2) We expect future implant procedures will be performed under the guidance of such pre-calculated trajectories. To assess the applicability, we randomly perturb the tracks to mimic the manual implant errors. Our studies showed the impact of these perturbations are negligible, which is compensated by the least distance programming. Conclusions: We developed a new inverse planning system for prostate HDR therapy that can find optimal implant trajectories while minimizing the number of implants. For future work, we plan to integrate our new inverse planning system with an existing needle tracking system.« less
NASA Astrophysics Data System (ADS)
Taschereau, Richard
Cette these concerne les implants permanents pour la prostate. Les isotopes employes, le 103Pd et l'125I, semblent produire les memes resultats cliniques: le premier a cause d'une radiation plus efficace et le second a cause de sa demi-vie plus longue. La recherche utilise le cadre theorique de la microdosimetrie et des simulations Monte Carlo. Elle propose d'employer le spectre d'ejection dans le calcul de l'efficacite; ce changement fait passer l'efficacite relative du 103Pd de 10% a 5%. Elle montre ensuite qu'il est possible d'ameliorer l'efficacite de la radiation de 125I par l'exploitation des rayons X caracteristiques de la capsule. Une source amelioree faite de molybdene et d'yttrium est donnee en exemple. Elle procure une radiation de 5--7% plus efficace, ce qui surclasse les deux sources existantes. Les applications ne se limitent pas au traitement de la prostate; le traitement du melanome oculaire et la curietherapie endovasculaire pourraient en beneficier.
Nakamura, T
1992-07-01
The possibility of repairing the defect of the pars interarticularis (pars defect) with Bone Morphogenetic Protein (BMP) and fibrin glue was studied. The pars defect established in the 5th lumbar vertebra of Wistar rat was treated with surgical implantation of a composite consisting of BMP, fibrin glue and autologous cancellous bone. At 3, 6, 9 and 12 weeks after implantation, the osteoinductive activity in the pars defect was observed histologically and compared with that of other composite implants such as BMP with fibrin glue, autologous cancellous bone alone and autologous cancellous bone with fibrin glue. Although perfect bone fusion was not obtained with any of the composites employed, a significant increase in bone formation was seen in a composite of BMP, fibrin glue and autologous cancellous bone (p less than 0.01) as compared with that seen in the others. Consequently, implantation of BMP and fibrin glue combined with some biomaterials which support osteo-induction of BMP and stabilize the pars defect might be successfully applied to repair the pars defect.
Garsa, Adam A; Verma, Vivek; Michalski, Jeff M; Gay, Hiram A
2014-01-01
To describe a transperineal ultrasound-guided technique for implantation of electromagnetic transponders into the prostatic fossa. Patients were placed in the dorsal lithotomy position, and local anesthetic was administered. On ultrasound, the bladder, urethra, vesicourethral anastomosis, rectum, and the prostatic fossa were carefully identified. Three transponders were implanted into the prostatic fossa under ultrasound guidance in a triangular configuration and implantation was verified by fluoroscopy. Patients underwent computed tomography (CT) simulation approximately 1 week later. All patients in this study were subsequently treated with intensity modulated radiation therapy (IMRT) to the prostatic fossa. From 2008 to 2012, 180 patients received transperineal implantation of electromagnetic transponders into the prostatic fossa and subsequently received IMRT. There were no cases of severe hematuria or rectal bleeding requiring intervention. There were no grade 3 or 4 toxicities. Three patients (1.7%) had a transponder missing on the subsequent CT simulation. Thirteen patients (7.3%) had transponder migration with a geometric residual that exceeded 2 mm for 3 consecutive days (5.6%) or rotation that exceeded 10 degrees for 5 consecutive days (1.7%). These patients underwent a resimulation CT scan to identify the new transponder coordinates. A transperineal technique for implantation of electromagnetic transponders into the prostatic fossa is safe and well tolerated, with no severe toxicity after implantation. There is a low rate of transponder loss or migration.
Laparoscopic implantation of an artificial urinary sphincter around the prostatic urethra
Chłosta, Piotr; Aboumarzouk, Omar; Bondad, Jasper; Szopiński, Tomasz; Korzelik, Ignacy; Borówka, Andrzej
2015-01-01
Objective To report the first laparoscopic periprostatic implantation of an artificial urinary sphincter (AUS) after a transurethral resection of the prostate. Background The implantation of an AUS is a standard procedure for severe urinary incontinence. In men it is usually implanted through a perineal approach, with the cuff placed around the bulbous urethra, bladder neck, or even around the prostate. Method We report a laparoscopic periprostatic implantation of an AUS after a transurethral resection of a prostate in a 72-year-old-man with incontinence. Results The operative duration was 180 min and the blood loss was 150 mL. There were no complications. After activating the AUS the patient was totally continent. Conclusion The laparoscopic periprostatic implantation of an AUS is a safe, effective and considerably less invasive procedure. PMID:26413345
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narayana, V; McLaughlin, P; University of Michigan, Ann Arbor, MI
2015-06-15
Purpose: In this study, the adequacy of target expansions on the combined external beam and implant dose was examined based on the measured daily motion of the prostate. Methods: Thirty patients received an I–125 prostate implant prescribed to dose of 90Gy. This was followed by external beam to deliver a dose of 90Gyeq (external beam equivalent) to the prostate over 25 to 30 fractions. An ideal IMRT plan was developed by optimizing the external beam dose based on the delivered implant dose. The implant dose was converted to an equivalent external beam dose using the linear quadratic model. Patients weremore » set up on the treatment table by daily orthogonal imaging and aligning the marker seeds in the prostate. Orthogonal images were obtained at the end of treatment to assess prostate intrafraction motion. Based on the observed motion of the markers between the initial and final images, 5 individual plans showing the actual dose delivered to the patient were calculated. A final true dose distribution was established based on summing the implant dose and the 5 external beam plans. Dose to the prostate, seminal vesicles, lymphnodes and normal tissues, rectal wall, urethra and lower sphincter were calculated and compared to ideal. On 18 patients who were sexually active, dose to the corpus cavernosum and internal pudendal artery was also calculated. Results: The average prostate motion in 3 orthogonal directions was less than 1 mm with a standard deviation of less than +2 mm. Dose and volume parameters showed that there was no decrease in dose to the targets and a marginal decrease in dose to in normal tissues. Conclusion: Dose delivered by seed implant moves with the prostate, decreasing the impact of intrafractions dose movement on actual dose delivered. Combined brachytherapy and external beam dose delivered to the prostate was not sensitive to prostate motion.« less
Skovgaard, Dorthe; Persson, Morten; Kjaer, Andreas
2016-01-01
Overexpression of urokinase-type plasminogen activator receptors (uPAR) represents an important biomarker for aggressiveness in most common malignant diseases, including prostate cancer (PC). Accordingly, uPAR expression either assessed directly in malignant PC tissue or assessed directly in plasma (intact/cleaved forms)-provides independent additional clinical information to that contributed by PSA, Gleason score, and other relevant pathological and clinical parameters. In this respect, non-invasive molecular imaging by positron emission tomography (PET) offers a very attractive technology platform, which can provide the required quantitative information on the uPAR expression profile, without the need for invasive procedures and the risk of missing the target due to tumor heterogeneity. These observations support non-invasive PET imaging of uPAR in PC as a clinically relevant diagnostic and prognostic imaging method. In this review, we will focus on the recent development of uPAR PET and the relevance within prostate cancer imaging. Novel antibody and small-molecule radiotracers-targeting uPAR, including a series of uPAR-targeting PET ligands, based on the high affinity peptide ligand AE105, have been synthesized and tested in vitro and in vivo in preclinical murine xenograft models and, recently, in a first-ever clinical uPAR PET study in cancer patients, including patients with PC. In this phase I study, a high and specific uptake of the tracer 64 Cu-DOTA-AE105 was found in both primary tumors and lymph node metastases. The results are encouraging and support large-scale clinical trials to determine the utility of uPAR PET in the management of patients with PC with the goal of improving outcome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, X; Rahimian, J; Goy, B
Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images.more » Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA values as well as patients’ survival are warranted.« less
Raben, Adam; Rusthoven, Kyle E; Sarkar, Abrihup; Glick, Andrew; Benge, Bruce; Jacobs, Dayee; Raben, David
2009-01-01
Favorable dosimetric results have been reported using intraoperative inverse optimization (IO) for permanent prostate brachytherapy. The clinical implications of these improvements in dosimetry are unclear. We review toxicity and early biochemical outcomes for patients implanted using IO technique. Between 2001 and 2007, 165 patients received permanent prostate implants using real-time IO and had >/=3 months of followup. Dose constraints for inverse planning were: the prostate volume receiving 100% of the prescription dose [prostate V(100)] was >95%; the dose received by 90% of the gland [prostate D(90)] was within the 140-180 by dose range; the volume of urethra receiving 150% of the prescription dose [urethra V(150)] was <30%; and the volume of rectal wall receiving 110% of the prescription dose [rectal V(110)] was <1.0 cc. Toxicity was prospectively scored using the Radiation Therapy Oncology Group toxicity scale and the International Prostate Symptom Score questionnaire. Biochemical control was determined using the nadir + 2 ng/mL definition. Mean followup was 30 months (range, 6-63 months). Risk classification was low risk in 89% and intermediate risk in 11%. Iodine-125 sources were used for 161 implants and palladium-103 sources for four implants. The median number of seeds and total activity implanted were 61 and 999 MBq, respectively, for a median prostate volume of 33.6 cc. Late GU and GI morbidity was uncommon. Among patients with at least 24 months followup, 16% had persistent Grade 2-3 urinary morbidity. Grade 2 rectal bleeding occurred in 1 patient (0.6%). Biochemical failure has occurred in only 4 patients at last followup. IO technique for prostate brachytherapy is associated with low rates of late morbidity and excellent early biochemical control. Additionally, the number of seeds and total implanted activity required to achieve a high-quality implant are lower compared with historical controls.
Influence of the number of elongated fiducial markers on the localization accuracy of the prostate
NASA Astrophysics Data System (ADS)
de Boer, Johan; de Bois, Josien; van Herk, Marcel; Sonke, Jan-Jakob
2012-10-01
Implanting fiducial markers for localization purposes has become an accepted practice in radiotherapy for prostate cancer. While many correction strategies correct for translations only, advanced correction protocols also require knowledge of the rotation of the prostate. For this purpose, typically, three or more markers are implanted. Elongated fiducial markers provide more information about their orientation than traditional round or cylindrical markers. Potentially, fewer markers are required. In this study, we evaluate the effect of the number of elongated markers on the localization accuracy of the prostate. To quantify the localization error, we developed a model that estimates, at arbitrary locations in the prostate, the registration error caused by translational and rotational uncertainties of the marker registration. Every combination of one, two and three markers was analysed for a group of 24 patients. The average registration errors at the prostate surface were 0.3-0.8 mm and 0.4-1 mm for registrations on, respectively, three markers and two markers located on different sides of the prostate. Substantial registration errors (2.0-2.2 mm) occurred at the prostate surface contralateral to the markers when two markers were implanted on the same side of the prostate or only one marker was used. In conclusion, there is no benefit in using three elongated markers: two markers accurately localize the prostate if they are implanted at some distance from each other.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mashouf, S; Merino, T; Ravi, A
Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contoursmore » in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.« less
Widespread expression of prostate apoptosis response-4 in nasopharyngeal carcinoma.
Lee, Jeng-Woei; Hsiao, Wei-Ting; Lee, Kuei-Fang; Sheu, Lai-Fa; Hsu, Hsue-Yin; Hsu, Lee-Ping; Su, Borcherng; Lee, Moon-Sing; Hsu, Yih-Chih; Chang, Chung-Hsing
2010-07-01
Prostate apoptosis response-4 (Par-4) augments apoptosis in various tumors, either during apoptotic insult or by ectopic overexpression. However, investigation of Par-4 expression in nasopharyngeal carcinoma (NPC) is lacking. Specimens from patients with NPC, hypopharyngeal carcinoma (HPC), or oral cavity cancer were examined for Par-4 expression using immunohistochemistry. NPC cell proliferation and apoptosis were analyzed using immunohistochemical staining for Ki67, B-cell lymphoma 2 (Bcl-2), and in situ terminal deoxyribonucleotidyl transferase (TdT)-mediated biotin-16-dUTP nick end-labeling (TUNEL) assay, respectively. Par-4 was ubiquitously expressed in NPC biopsies (96.2%, 25/26) and was significantly higher than in HPC (47.6%, 50/105, p < .0001) and oral cavity cancers (38.7%, 12/31, p < .0001). Remarkably, apoptosis of NPC cells was absent and Par-4 expression was associated with obvious expression of Bcl-2 and Ki67 in all patients tested with NPC. Immunohistochemistry results showed widespread expression of Par-4 in NPC and revealed sustainable proliferation of NPC cells regardless of Par-4 expression. .(c) 2009 Wiley Periodicals, Inc.
SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narayana, V; McLaughlin, P; University of Michigan, Ann Arbor, MI
Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mmmore » expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Genebes, Caroline, E-mail: genebes.caroline@claudiusregaud.fr; Filleron, Thomas; Graff, Pierre
2013-11-15
Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-riskmore » and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes.« less
Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G
2003-01-01
To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (p<0.001), and the 1-month CT volume was 43.6 cm(3) (p<0.001). The mean difference between the OR dose received by 90% of the prostate (D(90)) and the CT D(90) was 3.4% (95% confidence interval, 2.5-6.6%; p=0.034). The mean dose to 30% of the urethra was 120% of prescription in the OR and 138% on CT. The mean difference was 18% (95% confidence interval, 13-24%; p<0.001). Although small differences exist between the OR and CT dosimetry results, these data suggest that this intraoperative implant dosimetric representation system provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.
Hata, Junya; Satoh, Yuichi; Akaihata, Hidenori; Hiraki, Hiroyuki; Ogawa, Soichiro; Haga, Nobuhiro; Ishibashi, Kei; Aikawa, Ken; Kojima, Yoshiyuki
2016-07-01
To characterize the molecular features of benign prostatic hyperplasia by carrying out a gene expression profiling analysis in a rat model. Fetal urogenital sinus isolated from 20-day-old male rat embryo was implanted into a pubertal male rat ventral prostate. The implanted urogenital sinus grew time-dependently, and the pathological findings at 3 weeks after implantation showed epithelial hyperplasia as well as stromal hyperplasia. Whole-genome oligonucleotide microarray analysis utilizing approximately 30 000 oligonucleotide probes was carried out using prostate specimens during the prostate growth process (3 weeks after implantation). Microarray analyses showed 926 upregulated (>2-fold change, P < 0.01) and 3217 downregulated genes (<0.5-fold change, P < 0.01) in benign prostatic hyperplasia specimens compared with normal prostate. Gene ontology analyses of upregulated genes showed predominant genetic themes of involvement in development (162 genes, P = 2.01 × 10(-4) ), response to stimulus (163 genes, P = 7.37 × 10(-13) ) and growth (32 genes, P = 1.93 × 10(-5) ). When we used both normal prostate and non-transplanted urogenital sinuses as controls to identify benign prostatic hyperplasia-specific genes, 507 and 406 genes were upregulated and downregulated, respectively. Functional network and pathway analyses showed that genes associated with apoptosis modulation by heat shock protein 70, interleukin-1, interleukin-2 and interleukin-5 signaling pathways, KIT signaling pathway, and secretin-like G-protein-coupled receptors, class B, were relatively activated during the growth process in the benign prostatic hyperplasia specimens. In contrast, genes associated with cholesterol biosynthesis were relatively inactivated. Our microarray analyses of the benign prostatic hyperplasia model rat might aid in clarifying the molecular mechanism of benign prostatic hyperplasia progression, and identifying molecular targets for benign prostatic hyperplasia treatment. © 2016 The Japanese Urological Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheu, R; Powers, A; McGee, H
Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, andmore » 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.« less
Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.
Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J
2006-01-01
Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kehwar, Than S., E-mail: kehwarts@upmc.ed; Jones, Heather A.; Huq, M. Saiful
2011-06-01
Purpose: To study the influence of prostatic edema on postimplant physical and radiobiological parameters using {sup 131}Cs permanent prostate seed implants. Methods and Materials: Thirty-one patients with early prostate cancer who underwent {sup 131}Cs permanent seed implantation were evaluated. Dose-volume histograms were generated for each set of prostate volumes obtained at preimplantation and postimplantion days 0, 14, and 28 to compute quality indices (QIs) and fractional doses at level x (FD{sub x}). A set of equations for QI, FD{sub x}, and biologically effective doses at dose level D{sub x} (BED{sub x}) were defined to account for edema changes with timemore » after implant. Results: There were statistically significant differences found between QIs of pre- and postimplant plans at day 0, except for the overdose index (ODI). QIs correlated with postimplant time, and FD{sub x} was found to increase with increasing postimplant time. With the effect of edema, BED at different dose levels showed less improvement due to the short half-life of {sup 131}Cs, which delivers about 85% of the prescribed dose before the prostate reaches its original volume due to dissipation of edema. Conclusions: Results of the study show that QIs, FD{sub x}, and BEDs at the level of D{sub x} changed from preneedle plans to postimplant plans and have statistically significant differences (p < 0.05), except for the ODI (p = 0.106), which suggests that at the time of {sup 131}C seed implantation, the effect of edema must be accounted for when defining the seed positions, to avoid the possibility of poor dosimetric and radiobiologic results for {sup 131}Cs seed implants.« less
Implant therapy - prostate cancer; Radioactive seed placement; Internal radiation therapy - prostate; High dose radiation (HDR) ... CT scan to plan and then place the seeds that deliver radiation into your prostate. The seeds ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zoberi, J.
Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR ismore » U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.« less
Novel role of prostate apoptosis response-4 tumor suppressor in B-cell chronic lymphocytic leukemia.
McKenna, Mary K; Noothi, Sunil K; Alhakeem, Sara S; Oben, Karine Z; Greene, Joseph T; Mani, Rajeswaran; Perry, Kathryn L; Collard, James P; Rivas, Jacqueline R; Hildebrandt, Gerhard; Fleischman, Roger; Durbin, Eric B; Byrd, John C; Wang, Chi; Muthusamy, Natarajan; Rangnekar, Vivek M; Bondada, Subbarao
2018-04-25
Prostate apoptosis response-4 (Par-4), a pro-apoptotic tumor suppressor protein, is down regulated in many cancers including renal cell carcinoma, glioblastoma, endometrial and breast cancer. Par-4 induces apoptosis selectively in various types of cancer cells but not normal cells. We found that chronic lymphocytic leukemia (CLL) cells from human patients and from the Eµ-Tcl1 mice constitutively express Par-4 in greater amounts than normal B-1 or B-2 cells. Interestingly, knockdown of Par-4 in human CLL derived Mec-1 cells results in a robust increase in p21/WAF1 expression and decreased growth due to delayed G1 to S cell cycle transition. Lack of Par-4 also increased the expression of p21 and delayed CLL growth in Eμ-Tcl1 mice. Par-4 expression in CLL cells required constitutively active B-cell receptor (BCR) signaling, as inhibition of BCR signaling with FDA approved drugs caused a decrease in Par-4 mRNA and protein, and an increase in apoptosis. In particular, activities of Lyn, a Src family kinase, spleen tyrosine kinase and Bruton's tyrosine kinase are required for Par-4 expression in CLL cells, suggesting a novel regulation of Par-4 through BCR signaling. Together, these results suggest that Par-4 may play a novel pro-growth rather than pro-apoptotic role in CLL and could be targeted to enhance the therapeutic effects of BCR signaling inhibitors. Copyright © 2018 American Society of Hematology.
MO-B-BRC-04: MRI-Based Prostate HDR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mourtada, F.
2016-06-15
Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR ismore » U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.« less
MO-B-BRC-00: Prostate HDR Treatment Planning - Considering Different Imaging Modalities
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2016-06-15
Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR ismore » U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.« less
MO-B-BRC-02: Ultrasound Based Prostate HDR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Z.
2016-06-15
Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR ismore » U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.« less
Gregory, Kalvin J; Zhao, Bing; Bielenberg, Diane R; Dridi, Sami; Wu, Jason; Jiang, Weihua; Huang, Bin; Pirie-Shepherd, Steven; Fannon, Michael
2010-10-18
Vitamin D binding protein-macrophage activating factor (DBP-maf) is a potent inhibitor of tumor growth. Its activity, however, has been attributed to indirect mechanisms such as boosting the immune response by activating macrophages and inhibiting the blood vessel growth necessary for the growth of tumors. In this study we show for the first time that DBP-maf exhibits a direct and potent effect on prostate tumor cells in the absence of macrophages. DBP-maf demonstrated inhibitory activity in proliferation studies of both LNCaP and PC3 prostate cancer cell lines as well as metastatic clones of these cells. Flow cytometry studies with annexin V and propidium iodide showed that this inhibitory activity is not due to apoptosis or cell death. DBP-maf also had the ability to inhibit migration of prostate cancer cells in vitro. Finally, DBP-maf was shown to cause a reduction in urokinase plasminogen activator receptor (uPAR) expression in prostate tumor cells. There is evidence that activation of this receptor correlates with tumor metastasis. These studies show strong inhibitory activity of DBP-maf on prostate tumor cells independent of its macrophage activation.
Bielenberg, Diane R.; Dridi, Sami; Wu, Jason; Jiang, Weihua; Huang, Bin; Pirie-Shepherd, Steven; Fannon, Michael
2010-01-01
Background Vitamin D binding protein-macrophage activating factor (DBP-maf) is a potent inhibitor of tumor growth. Its activity, however, has been attributed to indirect mechanisms such as boosting the immune response by activating macrophages and inhibiting the blood vessel growth necessary for the growth of tumors. Methods and Findings In this study we show for the first time that DBP-maf exhibits a direct and potent effect on prostate tumor cells in the absence of macrophages. DBP-maf demonstrated inhibitory activity in proliferation studies of both LNCaP and PC3 prostate cancer cell lines as well as metastatic clones of these cells. Flow cytometry studies with annexin V and propidium iodide showed that this inhibitory activity is not due to apoptosis or cell death. DBP-maf also had the ability to inhibit migration of prostate cancer cells in vitro. Finally, DBP-maf was shown to cause a reduction in urokinase plasminogen activator receptor (uPAR) expression in prostate tumor cells. There is evidence that activation of this receptor correlates with tumor metastasis. Conclusions These studies show strong inhibitory activity of DBP-maf on prostate tumor cells independent of its macrophage activation. PMID:20976141
Ejaculatory Function After Permanent {sup 125}I Prostate Brachytherapy for Localized Prostate Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huyghe, Eric; Department of Urology and Andrology, Paul Sabatier University, CHU Paule de Viguier, Toulouse; Delannes, Martine
Purpose: Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent {sup 125}I prostate brachytherapy for localized prostate cancer. Patients and Methods: Of 270 sexually active men with localized prostate cancer treated with permanent {sup 125}I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Results: Of themore » 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Conclusion: Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.« less
Ejaculatory function after permanent 125I prostate brachytherapy for localized prostate cancer.
Huyghe, Eric; Delannes, Martine; Wagner, Fabien; Delaunay, Boris; Nohra, Joe; Thoulouzan, Matthieu; Shut-Yee, J Yeung; Plante, Pierre; Soulie, Michel; Thonneau, Patrick; Bachaud, Jean Marc
2009-05-01
Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent (125)I prostate brachytherapy for localized prostate cancer. Of 270 sexually active men with localized prostate cancer treated with permanent (125)I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Of the 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.
MO-B-BRC-01: Introduction [Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prisciandaro, J.
2016-06-15
Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR ismore » U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.« less
Prostate seed implant quality assessment using MR and CT image fusion.
Amdur, R J; Gladstone, D; Leopold, K A; Harris, R D
1999-01-01
After a seed implant of the prostate, computerized tomography (CT) is ideal for determining seed distribution but soft tissue anatomy is frequently not well visualized. Magnetic resonance (MR) images soft tissue anatomy well but seed visualization is problematic. We describe a method of fusing CT and MR images to exploit the advantages of both of these modalities when assessing the quality of a prostate seed implant. Eleven consecutive prostate seed implant patients were imaged with axial MR and CT scans. MR and CT images were fused in three dimensions using the Pinnacle 3.0 version of the ADAC treatment planning system. The urethra and bladder base were used to "line up" MR and CT image sets during image fusion. Alignment was accomplished using translation and rotation in the three ortho-normal planes. Accuracy of image fusion was evaluated by calculating the maximum deviation in millimeters between the center of the urethra on axial MR versus CT images. Implant quality was determined by comparing dosimetric results to previously set parameters. Image fusion was performed with a high degree of accuracy. When lining up the urethra and base of bladder, the maximum difference in axial position of the urethra between MR and CT averaged 2.5 mm (range 1.3-4.0 mm, SD 0.9 mm). By projecting CT-derived dose distributions over MR images of soft tissue structures, qualitative and quantitative evaluation of implant quality is straightforward. The image-fusion process we describe provides a sophisticated way of assessing the quality of a prostate seed implant. Commercial software makes the process time-efficient and available to any clinical practice with a high-quality treatment planning system. While we use MR to image soft tissue structures, the process could be used with any imaging modality that is able to visualize the prostatic urethra (e.g., ultrasound).
Cellular responses to various levels of sustained delivery of testosterone in the ventral prostate.
Cavett, W; Tucci, M; Cason, Z; Lemos, L; England, B; Tsao, A; Benghuzzi, H
1997-01-01
The objective of this study was to evaluate the effect of various dosages of testosterone (T) delivered in a sustained manner by means of tricalcium phosphate-lysine (TCPL) delivery system on morphological changes of prostatic tissue using adult male rats as a model. In this experiment, adult male rats (250-300 g BW) were randomly divided into five equal groups (n = 8). Rats in group I, II, and III were castrated and implanted subcutaneously with TCPL loaded with three different dosages (10, 100 and 200 mg T, respectively) of T. Rats in group IV were castrated and implanted with sharm TCPL capsules, and rats in group V served as intact unimplanted controls. Surgical aseptic techniques were performed according to standard laboratory procedures. At the end of 4 and 12 weeks post implantation, four animals from each group were sacrificed and the prostate tissues were collected, weighted, and embedded for histo-pathological evaluations. Data collected from this study have shown that exogenous intake of T delivered in a sustained manner for twelve weeks induced several pathophysiological conditions in ventral prostatic tissue in comparison to the control and sham operated groups. This phenomenon was found to be directly proportional to the dose or the level of sustained delivery. The results demonstrated that the use of 10 mg filled TCPL implants decreased the total mass weight of ventral prostate. Light microscopic evaluation of this group (Group I) revealed a cellular adaptation through an atrophy in the epithelium component. Cytopathological observations such as low cuboidal and thin glands, pleomorphism, and occasional presence of connective tissue stroma were detected. In contrast, ventral prostate collected from animals implanted with TCPL filled with 200 mg T (Group III) showed a significant increase in weights of the wet prostatic tissues in comparison to all groups. Histopathological evaluations demonstrated the following. (i) prostatic hypertrophy alone, or in conjunction with hyperplasia of the epithelial cells, (ii) less connective tissue stroma in comparison to the control group, (iii) occasional involvement of mitotic figures, and (iv) increased angiogenesis. No significant change was observed in those animals implanted with TCPL capsules containing 100 mg T compared to the intact control animals.
Todor, Dorin A; Barani, Igor J; Lin, Peck-Sun; Anscher, Mitchell S
2011-09-01
To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Nine plans, using 125I, 103Pd, and 131Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTVi) were delineated along with PTV (prostate+5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTVi were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. The EUBED of PTVi in the setting of primary 125I implant increased 20-66% when 103Pd and 131Cs were used compared with 125I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTVi (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todor, Dorin A., E-mail: dtodor@mcvh-vcu.edu; Barani, Igor J.; Lin, Peck-Sun
2011-09-01
Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants,more » prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.« less
Withaferin A Inhibits Prostate Carcinogenesis in a PTEN-deficient Mouse Model of Prostate Cancer.
Moselhy, Jim; Suman, Suman; Alghamdi, Mohammed; Chandarasekharan, Balaji; Das, Trinath P; Houda, Alatassi; Ankem, Murali; Damodaran, Chendil
2017-06-01
We recently demonstrated that AKT activation plays a role in prostate cancer progression and inhibits the pro-apoptotic function of FOXO3a and Par-4. AKT inhibition and Par-4 induction suppressed prostate cancer progression in preclinical models. Here, we investigate the chemopreventive effect of the phytonutrient Withaferin A (WA) on AKT-driven prostate tumorigenesis in a Pten conditional knockout (Pten-KO) mouse model of prostate cancer. Oral WA treatment was carried out at two different doses (3 and 5 mg/kg) and compared to vehicle over 45 weeks. Oral administration of WA for 45 weeks effectively inhibited primary tumor growth in comparison to vehicle controls. Pathological analysis showed the complete absence of metastatic lesions in organs from WA-treated mice, whereas discrete metastasis to the lungs was observed in control tumors. Immunohistochemical analysis revealed the down-regulation of pAKT expression and epithelial-to-mesenchymal transition markers, such as β-catenin and N-cadherin, in WA-treated tumors in comparison to controls. This result corroborates our previous findings from both cell culture and xenograft models of prostate cancer. Our findings demonstrate that the daily administration of a phytonutrient that targets AKT activation provides a safe and effective treatment for prostate cancer in a mouse model with strong potential for translation to human disease. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thaker, Nikhil G.; Kudchadker, Rajat J.; Swanson, David A.
2014-11-01
Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ({sup 125}I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parametersmore » were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB.« less
Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, C. D.; Kron, T.; Leahy, M.
Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set wasmore » assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.« less
Idota, Nozomi; Nakamura, Mami; Masui, Koji; Kakiuchi, Yasuhiro; Yamada, Kei; Ikegaya, Hiroshi
2017-03-01
We report here lessons learned from an autopsy case involving radioactive materials. We performed an autopsy of an unidentified mummified man with no available medical history whom from imaging findings we suspected had received radioactive seed implants for prostate brachytherapy. We returned the excised prostate and seeds to the body. A few days later, the body was identified by DNA matching and cremated. According to the man's medical record, he had undergone iodine-125 seeds implantation for prostate cancer 11 months earlier. We should have removed the radioactive seeds from the body to prevent radiation exposure to the bereaved family and/or environmental pollution due to cremation. Surprisingly, one seed was found in the stored prostate specimen. Forensic experts should be cognizant of the risk of both radiation exposure in the autopsy room and environmental pollution. We must remain abreast of the latest advances in medicine. © 2016 American Academy of Forensic Sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mashouf, S; University of Toronto, Dept. of Radiation Oncology, Toronto, ON; Ravi, A
Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH).more » The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of the contouring uncertainty on V100 and D90 fortunately, has a conservative effect of underestimating the prostate coverage.« less
Long-Term Outcomes of Alternative Brachytherapy Techniques for Early Prostate Cancer. Addendum
2008-10-01
radical prostatectomy. The National Medicare Experience: 1988-1990 (updated June 1993). Urology 1993;42:622-9. 3. Litwin MS, Hays RD, Fink A, Ganz PA...implantation for early-stage prostatic cancer. J Clin Oncol 1999;17:517-22. 33. Brandeis JM, Litwin MS, Burnison CM, Reiter RE. Quality of life outcomes after...combination radiotherapy for patients with prostate cancer. I-125 implant followed by external-beam radiation. Cancer 1995;75:2383-91. 35. Litwin M
MR and CT image fusion for postimplant analysis in permanent prostate seed implants.
Polo, Alfredo; Cattani, Federica; Vavassori, Andrea; Origgi, Daniela; Villa, Gaetano; Marsiglia, Hugo; Bellomi, Massimo; Tosi, Giampiero; De Cobelli, Ottavio; Orecchia, Roberto
2004-12-01
To compare the outcome of two different image-based postimplant dosimetry methods in permanent seed implantation. Between October 1999 and October 2002, 150 patients with low-risk prostate carcinoma were treated with (125)I and (103)Pd in our institution. A CT-MRI image fusion protocol was used in 21 consecutive patients treated with exclusive brachytherapy. The accuracy and reproducibility of the method was calculated, and then the CT-based dosimetry was compared with the CT-MRI-based dosimetry using the dose-volume histogram (DVH) related parameters recommended by the American Brachytherapy Society and the American Association of Physicists in Medicine. Our method for CT-MRI image fusion was accurate and reproducible (median shift <1 mm). Differences in prostate volume were found, depending on the image modality used. Quality assurance DVH-related parameters strongly depended on the image modality (CT vs. CT-MRI): V(100) = 82% vs. 88%, p < 0.05. D(90) = 96% vs. 115%, p < 0.05. Those results depend on the institutional implant technique and reflect the importance of lowering inter- and intraobserver discrepancies when outlining prostate and organs at risk for postimplant dosimetry. Computed tomography-MRI fused images allow accurate determination of prostate size, significantly improving the dosimetric evaluation based on DVH analysis. This provides a consistent method to judge a prostate seed implant's quality.
Wong, Dennis T L; Bertaso, Angela G; Liew, Gary Y H; Thomson, Viji S; Cunnington, Michael S; Richardson, James D; Gooley, Robert; Lockwood, Siobhan; Meredith, Ian T; Worthley, Matthew I; Worthley, Stephen G
2013-04-01
Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Medtronic CoreValve bioprosthesis. The smallest (D(min)) and largest (D(max)) orthogonal diameters in the basal ring of the aortic annulus were determined. We defined circularity of aortic annulus using the eccentricity index (1 - D(min)/D(max)). The primary endpoint was early occurrence of significant PAR, defined as > grade II PAR by postprocedural aortography. Eighty-four patients, mean age 83 ± 4 years with a mean aortic valve area of 0.7 ± 0.2 cm² were included. Twenty patients had postprocedural PAR > grade II. Using a receiver operating characteristic (ROC) analysis, eccentricity index correlated with significant PAR (AUC = 0.834; P=.034). A retrospectively determined eccentricity index cut-off of >0.25 was related to significant PAR with a sensitivity of 80%, specificity of 86%, and negative predictive value of 95% (P<.001). On univariate logistic regression, eccentricity index of >0.25 (P<.001) and device implantation depth (P=.015) correlated with significant PAR, while other parameters such as annular calcification and cover index did not. On multivariate analysis including only parameters with P<.1 on univariate analysis, eccentricity index >0.25 was the sole independent predictor of significant PAR. Eccentricity index is related to significant PAR after TAVI with Medtronic CoreValve. Further larger studies are required to determine the utility of this novel index in screening suitable patients for this procedure.
SU-F-T-41: 3D MTP-TRUS for Prostate Implant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, P
Purpose: Prostate brachytherapy is an effective treatment for early prostate cancer. The current prostate implant is limited to using 2D transrectal ultrassound (TRUS) or machenical motor driven 2D array either in the end or on the side. Real-time 3D images can improve the accuracy of the guidance of prostate implant. The concept of our system is to allow realtime full visualization of the entire prostate with the multiple transverse scan. Methods: The prototype of 3D Multiple-Transverse-Plane Transrectal Ultrasound probe (MTP-TRUS) has been designed by us and manufactured by Blatek inc. It has 7 convex linear arrays and each array hasmore » 96 elements. It is connected to cQuest Fire bird research system (Cephasonics inc.) which is a flexible and configurable ultrasound-development platform. The size of cQuest Firebird system is compact and supports the real-time wireless image transferring. A relay based mux board is designed for the cQuest Firebird system to be able to connect 672 elements. Results: The center frequency of probe is 6MHz±10%. The diameter of probe is 3cm and the length is 20cm. The element pitch is 0.205 mm. Array focus is 30mm and spacing 1.6cm. The beam data for each array was measured and met our expectation. The interface board of MTP-TURS is made and able to connect to cQuest Firebird system. The image display interface is still under the development. Our real-time needle tracking algorithm will be implemented too. Conclusion: Our MTP-TRUS system for prostate implant will be able to acquire real-time 3D images of prostate and do the real-time needle segmentation and tracking. The system is compact and have wireless function.« less
Dose reduction in LDR brachytherapy by implanted prostate gold fiducial markers.
Landry, Guillaume; Reniers, Brigitte; Lutgens, Ludy; Murrer, Lars; Afsharpour, Hossein; de Haas-Kock, Danielle; Visser, Peter; van Gils, Francis; Verhaegen, Frank
2012-03-01
The dosimetric impact of gold fiducial markers (FM) implanted prior to external beam radiotherapy of prostate cancer on low dose rate (LDR) brachytherapy seed implants performed in the context of combined therapy was investigated. A virtual water phantom was designed containing a single FM. Single and multi source scenarios were investigated by performing Monte Carlo dose calculations, along with the influence of varying orientation and distance of the FM with respect to the sources. Three prostate cancer patients treated with LDR brachytherapy for a recurrence following external beam radiotherapy with implanted FM were studied as surrogate cases to combined therapy. FM and brachytherapy seeds were identified on post implant CT scans and Monte Carlo dose calculations were performed with and without FM. The dosimetric impact of the FM was evaluated by quantifying the amplitude of dose shadows and the volume of cold spots. D(90) was reported based on the post implant CT prostate contour. Large shadows are observed in the single source-FM scenarios. As expected from geometric considerations, the shadows are dependent on source-FM distance and orientation. Large dose reductions are observed at the distal side of FM, while at the proximal side a dose enhancement is observed. In multisource scenarios, the importance of shadows appears mitigated, although FM at the periphery of the seed distribution caused underdosage (
2015-10-01
epididymis tumors, and performed implantation of testosterone pellets to continue support prostate tumor growth. Our recent data suggest that these...will eliminate the concerns on epididymis tumors. We also proposed to perform subcutaneous implantation of testosterone pellets to continue...USAMRMC ACURO. We have initiated performing the early castration and testosterone pellet implantation on the young PB-Cre4/CAG- SMIL/p53loxP/loxP
New transurethral system for interstitial radiation of prostate cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumgartner, G.; Callahan, D.; McKiel, C.F. Jr.
Direct endoscopic implantation of radioactive materials for carcinoma of the prostate without an open operation was accomplished by the use of modified existing transurethral instrumentation and techniques. The closed approach seems applicable particularly to the geriatric population, which is afflicted more commonly but is frequently not treated because of concurrent diseases or because the patient had transurethral resection of the prostate as a diagnostic procedure. Eleven patients were implanted using the transurethral route. Implantations were accomplished successfully with extremely low morbidity. Along with more conventional dosimetry studies, computer tomography was used to assess the placement of seeds. The direct visualizationmore » of the method suggests a potential for greater precision of seed placement as illustrated by computer tomography. In addition, this new instrumentation and method offers a low-risk procedure for carcinoma of the prostate that can be performed on an outpatient basis for selected patients.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, D; Usmani, N; Sloboda, R
The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used tomore » infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruijf, Willy J.M. de, E-mail: kruijf.de.w@bvi.nl; Verstraete, Jan; Neustadter, David
2013-02-01
Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performedmore » to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.« less
de Kruijf, Willy J M; Verstraete, Jan; Neustadter, David; Corn, Benjamin W; Hol, Sandra; Venselaar, Jack L M; Davits, Rob J; Wijsman, Bart P; Van den Bergh, Laura; Budiharto, Tom; Oyen, Raymond; Haustermans, Karin; Poortmans, Philip M P
2013-02-01
To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ((192)Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye. Copyright © 2013 Elsevier Inc. All rights reserved.
Todor, Dorin A; Anscher, Mitchell S; Karlin, Jeremy D; Hagan, Michael P
2014-01-01
This is a retrospective study in which we define multiple metrics for similarity and then inquire on the relationship between similarity and currently used dosimetric quantities describing preimplant and postimplant plans. We analyzed a unique cohort of 94 consecutively performed prostate seed implant patients, associated with excellent dosimetric and clinical outcomes. For each patient, an ultrasound (US) preimplant and two CT postimplant (Day 0 and Day 30) studies were available. Measures for similarity were created and computed using feature vectors based on two classes of moments: first, invariant to rotation and translation, and the second polar-radius moments invariant to rotation, translation, and scaling. Both similarity measures were calibrated using controlled perturbations (random and systematic) of seed positions and contours in different size implants, thus producing meaningful numerical threshold values used in the clinical analysis. An important finding is that similarity, for both seed distributions and contours, improves significantly when scaling invariance is added to translation and rotation. No correlation between seed and contours similarity was found. In the setting of preplanned prostate seed implants using preloaded needles, based on our data, similarity between preimplant and postimplant plans does not correlate with either minimum dose to 90% of the volume of the prostate or analogous similarity metrics for prostate contours. We have developed novel tools and metrics, which will allow practitioners to better understand the relationship between preimplant and postimplant plans. Geometrical similarity between a preplan and an actual implant, although useful, does not seem to be necessary to achieve minimum dose to 90% of the volume of the prostate-good dosimetric implants. Copyright © 2014 American Brachytherapy Society. All rights reserved.
Fiducial marker guided prostate radiotherapy: a review
Jain, Suneil; Hounsell, Alan R; O'Sullivan, Joe M
2016-01-01
Image-guided radiotherapy (IGRT) is an essential tool in the accurate delivery of modern radiotherapy techniques. Prostate radiotherapy positioned using skin marks or bony anatomy may be adequate for delivering a relatively homogeneous whole-pelvic radiotherapy dose, but these surrogates are not reliable when using reduced margins, dose escalation or hypofractionated stereotactic radiotherapy. Fiducial markers (FMs) for prostate IGRT have been in use since the 1990s. They require surgical implantation and provide a surrogate for the position of the prostate gland. A variety of FMs are available and they can be used in a number of ways. This review aimed to establish the evidence for using prostate FMs in terms of feasibility, implantation procedures, types of FMs used, FM migration, imaging modalities used and the clinical impact of FMs. A search strategy was defined and a literature search was carried out in Medline. Inclusion and exclusion criteria were applied, which resulted in 50 articles being included in this review. The evidence demonstrates that FMs provide a more accurate surrogate for the position of the prostate than either external skin marks or bony anatomy. A combination of FM alignment and soft-tissue analysis is currently the most effective and widely available approach to ensuring accuracy in prostate IGRT. FM implantation is safe and well tolerated. FM migration is possible but minimal. Standardization of all techniques and procedures in relation to the use of prostate FMs is required. Finally, a clinical trial investigating a non-surgical alternative to prostate FMs is introduced. PMID:27585736
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steiner, J; Matthews, K; Jia, G
Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strandsmore » of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.« less
Sowing seeds: transperineal implantation.
Amerine, E; Nagle, G M; Bollinger, J R
2000-02-01
Prostate cancer, the second leading cause of male deaths in the United States, has increased by 126% since 1987 (Stephenson, 1998). Early diagnosis is attributed to public awareness and technologic advances. Multiple options for definitive treatment with equally positive outcomes dramatically influence the patient's decision-making process. One popular option for these patients is transperineal implantation of radioactive seeds into the prostate.
Maintenance of human hyperplastic prostate implants at different sites in athymic mice.
Soós, G; Debiec-Rychter, M; Jones, R F; Zukowski, K; Haas, G P; Wang, C Y
1995-01-01
The present study determined the influence of implantation sites, androgens, and the graft's fibrovascular elements on the maintenance of epithelial elements of human benign hyperplastic prostate tissue (BPH) in the nude mouse. BPH fragments prepared from fresh surgical specimens were implanted subcutaneously (s.c.), intraperitoneally (i.p.), or under the renal capsules (r.c.) into male Beige nude mice, which had been implanted s.c. with a Silastic tube filled with 4-dihydrotestosterone (DHT) or cholesterol. Two weeks later the BPH tissues were removed from the mouse and examined microscopically. The implants from all three sites maintained a comparable morphology, with epithelial and/or angio-leiomyomatous stromal hyperplastic appearance, without striking signs of atrophy, irrespective of supplementation with DHT. Expression of proliferating cell nuclear antigen in the implants was comparable, indicating that there was no significant influence of implantation site on the proliferative ability of either epithelia or the stromal fibroblasts. The PCNA-positive cells in the implants, including the vascular and myofibrous elements, hybridized in situ to a human-specific repeated-sequence DNA probe, indicating that these proliferating cells were of human origin. Our data suggest that during the early phases of the adaptation and maintenance of BPH implants, survival of epithelial cells is actively supported by fibro-vascular mesenchymal elements of the prostate grafts in a manner apparently unaffected by DHT supplements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chibani, Omar; Williamson, Jeffrey F.; Todor, Dorin
2005-08-15
A Monte Carlo study is carried out to quantify the effects of seed anisotropy and interseed attenuation for {sup 103}Pd and {sup 125}I prostate implants. Two idealized and two real prostate implants are considered. Full Monte Carlo simulation (FMCS) of implants (seeds are physically and simultaneously simulated) is compared with isotropic point-source dose-kernel superposition (PSKS) and line-source dose-kernel superposition (LSKS) methods. For clinical pre- and post-procedure implants, the dose to the different structures (prostate, rectum wall, and urethra) is calculated. The discretized volumes of these structures are reconstructed using transrectal ultrasound contours. Local dose differences (PSKS versus FMCS and LSKSmore » versus FMCS) are investigated. The dose contributions from primary versus scattered photons are calculated separately. For {sup 103}Pd, the average absolute total dose difference between FMCS and PSKS can be as high as 7.4% for the idealized model and 6.1% for the clinical preprocedure implant. Similarly, the total dose difference is lower for the case of {sup 125}I: 4.4% for the idealized model and 4.6% for a clinical post-procedure implant. Average absolute dose differences between LSKS and FMCS are less significant for both seed models: 3 to 3.6% for the idealized models and 2.9 to 3.2% for the clinical plans. Dose differences between PSKS and FMCS are due to the absence of both seed anisotropy and interseed attenuation modeling in the PSKS approach. LSKS accounts for seed anisotropy but not for the interseed effect, leading to systematically overestimated dose values in comparison with the more accurate FMCS method. For both idealized and clinical implants the dose from scattered photons represent less than 1/3 of the total dose. For all studied cases, LSKS prostate DVHs overestimate D{sub 90} by 2 to 5% because of the missing interseed attenuation effect. PSKS and LSKS predictions of V{sub 150} and V{sub 200} are overestimated by up to 9% in comparison with the FMCS results. Finally, effects of seed anisotropy and interseed attenuation must be viewed in the context of other significant sources of dose uncertainty, namely seed orientation, source misplacement, prostate morphological changes and tissue heterogeneity.« less
Zelefsky, Michael J; Cohen, Gilad N; Taggar, Amandeep S; Kollmeier, Marisa; McBride, Sean; Mageras, Gig; Zaider, Marco
Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program. Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage. The implanted seed positions were automatically segmented from the cone-beam images, fused onto a new set of acquired ultrasound images, reimported into the planning system, and recontoured. Dose distributions were recalculated based upon actual implanted seed coordinates and recontoured ultrasound images and were reviewed. If any dose deficiencies within the prostate target were identified, additional needles and seeds were added. Once an implant was deemed acceptable, the procedure was completed, and anesthesia was reversed. When the intraoperative ultrasound-based quality assurance assessment was performed after seed placement, the median volume receiving 100% of the dose (V100) was 93% (range, 74% to 98%). Before seed correction, 23% (6/26) of cases were noted to have V100 <90%. Based on this intraoperative assessment and replanning, additional seeds were placed into dose-deficient regions within the target to improve target dose distributions. Postcorrection, the median V100 was 97% (range, 93% to 99%). Following intraoperative dose corrections, all implants achieved V100 >90%. In these patients, postimplantation evaluation during the actual prostate seed implant procedure was successfully applied to determine the need for additional seeds to correct dose deficiencies before anesthesia reversal. When applied, this approach should significantly reduce intraoperative errors and chances for suboptimal dose delivery during prostate brachytherapy. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Goserelin implant is used in combination with radiation therapy and other medications to treat localized prostate cancer ... and other symptoms) and to help with the treatment of abnormal bleeding of the uterus. Goserelin implant ...
The use of nomograms in LDR-HDR prostate brachytherapy.
Pujades, Ma Carmen; Camacho, Cristina; Perez-Calatayud, Jose; Richart, José; Gimeno, Jose; Lliso, Françoise; Carmona, Vicente; Ballester, Facundo; Crispín, Vicente; Rodríguez, Silvia; Tormo, Alejandro
2011-09-01
The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR. For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms. Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification.
The use of nomograms in LDR-HDR prostate brachytherapy
Camacho, Cristina; Perez-Calatayud, Jose; Richart, José; Gimeno, Jose; Lliso, Françoise; Carmona, Vicente; Ballester, Facundo; Crispín, Vicente; Rodríguez, Silvia; Tormo, Alejandro
2011-01-01
Purpose The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. Material and methods Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR. Results For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms. Conclusions Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification. PMID:23346120
MRI/TRUS data fusion for prostate brachytherapy. Preliminary results.
Reynier, Christophe; Troccaz, Jocelyne; Fourneret, Philippe; Dusserre, André; Gay-Jeune, Cécile; Descotes, Jean-Luc; Bolla, Michel; Giraud, Jean-Yves
2004-06-01
Prostate brachytherapy involves implanting radioactive seeds (I125 for instance) permanently in the gland for the treatment of localized prostate cancers, e.g., cT1c-T2a N0 M0 with good prognostic factors. Treatment planning and seed implanting are most often based on the intensive use of transrectal ultrasound (TRUS) imaging. This is not easy because prostate visualization is difficult in this imaging modality particularly as regards the apex of the gland and from an intra- and interobserver variability standpoint. Radioactive seeds are implanted inside open interventional MR machines in some centers. Since MRI was shown to be sensitive and specific for prostate imaging whilst open MR is prohibitive for most centers and makes surgical procedures very complex, this work suggests bringing the MR virtually in the operating room with MRI/TRUS data fusion. This involves providing the physician with bi-modality images (TRUS plus MRI) intended to improve treatment planning from the data registration stage. The paper describes the method developed and implemented in the PROCUR system. Results are reported for a phantom and first series of patients. Phantom experiments helped characterize the accuracy of the process. Patient experiments have shown that using MRI data linked with TRUS data improves TRUS image segmentation especially regarding the apex and base of the prostate. This may significantly modify prostate volume definition and have an impact on treatment planning.
Methods for prostate stabilization during transperineal LDR brachytherapy.
Podder, Tarun; Sherman, Jason; Rubens, Deborah; Messing, Edward; Strang, John; Ng, Wan-Sing; Yu, Yan
2008-03-21
In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and training simulators.
Maeno, M; Lee, C; Kim, D M; Da Silva, J; Nagai, S; Sugawara, S; Nara, Y; Kihara, H; Nagai, M
2017-06-01
The aim of this study was to evaluate the barrier function of platelet-induced epithelial sheets on titanium surfaces. The lack of functional peri-implant epithelial sealing with basal lamina (BL) attachment at the interface of the implant and the adjacent epithelium allows for bacterial invasion, which may lead to peri-implantitis. Although various approaches have been reported to combat bacterial infection by surface modifications to titanium, none of these have been successful in a clinical application. In our previous study, surface modification with protease-activated receptor 4-activating peptide (PAR4-AP), which induced platelet activation and aggregation, was successful in demonstrating epithelial attachment via BL and epithelial sheet formation on the titanium surface. We hypothesized that the platelet-induced epithelial sheet on PAR4-AP-modified titanium surfaces would reduce bacterial attachment, penetration, and invasion. Titanium surface was modified with PAR4-AP and incubated with platelet-rich plasma (PRP). The aggregated platelets released collagen IV, a critical BL component, onto the PAR4-AP-modified titanium surface. Then, human gingival epithelial cells were seeded on the modified titanium surface and formed epithelial sheets. Green fluorescent protein (GFP)-expressing Escherichia coli was cultured onto PAR4-AP-modified titanium with and without epithelial sheet formation. While Escherichia coli accumulated densely onto the PAR4-AP titanium lacking epithelial sheet, few Escherichia coli were observed on the epithelial sheet on the PAR4-AP surface. No bacterial invasion into the interface of the epithelial sheet and the titanium surface was observed. These in vitro results indicate the efficacy of a platelet-induced epithelial barrier that functions to prevent bacterial attachment, penetration, and invasion on PAR4-AP-modified titanium.
Chang, Lynn
2014-01-01
Purpose To report outcomes on 5 patients treated with salvage partial low-dose-rate (LDR) 125-iodine (125I) permanent prostate seed brachytherapy (BT) for biopsy-proven locally persistent prostate cancer, following failure of dose-escalated external beam radiotherapy (EBRT). Material and methods A retrospective review of the Fox Chase Cancer Center prostate cancer database identified five patients treated with salvage partial LDR 125I seed implant for locally persistent disease following dose-escalated EBRT to 76-84 Gy in 2 Gy per fraction equivalent. All patients had post-EBRT biopsies confirming unilateral locally persistent prostate cancer. Pre-treatment, EBRT and BT details, as well as post-treatment characteristics were documented and assessed. Results The median follow-up post-implant was 41 months. All five patients exhibited low acute genitourinary and gastrointestinal toxicities. Increased erectile dysfunction was noted in three patients. There were no biochemical failures following salvage LDR 125I seed BT to date, with a median post-salvage PSA of 0.4 ng/mL. Conclusions In carefully selected patients with local persistence of disease, partial LDR 125I permanent prostate seed implant appears to be a feasible option for salvage local therapy with an acceptable toxicity profile. Further study is needed to determine long-term results of this approach. PMID:25337135
Dosimetric comparison between model 9011 and 6711 sources in prostate implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hualin, E-mail: zhang248@iupui.edu; Arizona Oncology Services, Phoenix, AZ; Beyer, David
2013-07-01
The purpose of this work is to evaluate the model 9011 iodine-125 ({sup 125}I) in prostate implants by comparing dosimetric coverage provided by the 6711 vs 9011 source implants. Postimplant dosimetry was performed in 18 consecutively implanted patients with prostate cancer. Two were implanted with the 9011 source and 16 with the 6711 source. For purposes of comparison, each implant was then recalculated assuming use of the other source. The same commercially available planning system was used and the specific source data for both 6711 and 9011 products were entered. The results of these calculations are compared side by sidemore » in the terms of the isodose values covering 100% (D100) and 90% (D90) of prostate volume, and the percentages of volumes of prostate, bladder, rectum, and urethra covered by 200% (V200), 150% (V150), 100% (V100), 50% (V50), and 20% (V20) of the prescribed dose as well. The 6711 source data overestimate coverage by 6.4% (ranging from 4.9% to 6.9%; median 6.6%) at D100 and by 6.6% (ranging from 6.2% to 6.8%; median 6.6%) at D90 compared with actual 9011 data. Greater discrepancies of up to 67% are seen at higher dose levels: average reduction for V100 is 2.7% (ranging from 0.6% to 7.7%; median 2.3%), for V150 is 14.6% (ranging from 6.1% to 20.5%; median 15.3%), for V200 is 14.9% (ranging from 4.8% to 19.1%; median 16%); similarly seen in bladder, rectal, and urethral coverage. This work demonstrates a clear difference in dosimetric behavior between the 9011 and 6711 sources. Using the 6711 source data for 9011 source implants would create a pronounced error in dose calculation. This study provides evidence that the 9011 source can provide the same dosimetric quality as the 6711 source, if properly used; however, the 6711 source data should not be considered as a surrogate for the 9011 source implants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, D; Usmani, N; Sloboda, R
Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogatemore » urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset of peripheral seeds involved, but lateral shearing movement can have greater consequences for local dose coverage.« less
SU-G-201-15: Nomogram as an Efficient Dosimetric Verification Tool in HDR Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, J; Todor, D
Purpose: Nomogram as a simple QA tool for HDR prostate brachytherapy treatment planning has been developed and validated clinically. Reproducibility including patient-to-patient and physician-to-physician variability was assessed. Methods: The study was performed on HDR prostate implants from physician A (n=34) and B (n=15) using different implant techniques and planning methodologies. A nomogram was implemented as an independent QA of computer-based treatment planning before plan execution. Normalized implant strength (total air kerma strength Sk*t in cGy cm{sup 2} divided by prescribed dose in cGy) was plotted as a function of PTV volume and total V100. A quadratic equation was used tomore » fit the data with R{sup 2} denoting the model predictive power. Results: All plans showed good target coverage while OARs met the dose constraint guidelines. Vastly different implant and planning styles were reflected on conformity index (entire dose matrix V100/PTV volume, physician A implants: 1.27±0.14, physician B: 1.47±0.17) and PTV V150/PTV volume ratio (physician A: 0.34±0.09, physician B: 0.24±0.07). The quadratic model provided a better fit for the curved relationship between normalized implant strength and total V100 (or PTV volume) than a simple linear function. Unlike the normalized implant strength versus PTV volume nomogram which differed between physicians, a unique quadratic model based nomogram (Sk*t)/D=−0.0008V2+0.0542V+1.1185 (R{sup 2}=0.9977) described the dependence of normalized implant strength on total V100 over all the patients from both physicians despite two different implant and planning philosophies. Normalized implant strength - total V100 model also generated less deviant points distorting the smoothed ones with a significantly higher correlation. Conclusion: A simple and universal, excel-based nomogram was created as an independent calculation tool for HDR prostate brachytherapy. Unlike similar attempts, our nomogram is insensitive to implant style and does not rely on reproducing dose calculations using TG-43 formalism, thus making it a truly independent check.« less
NASA Astrophysics Data System (ADS)
Westendorp, Hendrik; Nuver, Tonnis T.; Moerland, Marinus A.; Minken, André W.
2015-10-01
The geometry of a permanent prostate implant varies over time. Seeds can migrate and edema of the prostate affects the position of seeds. Seed movements directly influence dosimetry which relates to treatment quality. We present a method that tracks all individual seeds over time allowing quantification of seed movements. This linking procedure was tested on transrectal ultrasound (TRUS) and cone-beam CT (CBCT) datasets of 699 patients. These datasets were acquired intraoperatively during a dynamic implantation procedure, that combines both imaging modalities. The procedure was subdivided in four automatic linking steps. (I) The Hungarian Algorithm was applied to initially link seeds in CBCT and the corresponding TRUS datasets. (II) Strands were identified and optimized based on curvature and linefits: non optimal links were removed. (III) The positions of unlinked seeds were reviewed and were linked to incomplete strands if within curvature- and distance-thresholds. (IV) Finally, seeds close to strands were linked, also if the curvature-threshold was violated. After linking the seeds an affine transformation was applied. The procedure was repeated until the results were stable or the 6th iteration ended. All results were visually reviewed for mismatches and uncertainties. Eleven implants showed a mismatch and in 12 cases an uncertainty was identified. On average the linking procedure took 42 ms per case. This accurate and fast method has the potential to be used for other time spans, like Day 30, and other imaging modalities. It can potentially be used during a dynamic implantation procedure to faster and better evaluate the quality of the permanent prostate implant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mehrmohammadi, Mohammad; Kinnick, Randall R.; Fatemi, Mostafa, E-mail: fatemi.mostafa@mayo.edu
2014-09-15
Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped withmore » a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that ultimately may allow US-based real-time intraoperative dosimetry.« less
Mehrmohammadi, Mohammad; Alizad, Azra; Kinnick, Randall R.; Davis, Brian J.; Fatemi, Mostafa
2014-01-01
Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped with a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that ultimately may allow US-based real-time intraoperative dosimetry. PMID:25186418
Establishment of Epithelial Attachment on Titanium Surface Coated with Platelet Activating Peptide
Sugawara, Shiho; Maeno, Masahiko; Lee, Cliff; Nagai, Shigemi; Kim, David M.; Da Silva, John; Kondo, Hisatomo
2016-01-01
The aim of this study was to produce epithelial attachment on a typical implant abutment surface of smooth titanium. A challenging complication that hinders the success of dental implants is peri-implantitis. A common cause of peri-implantitis may results from the lack of epithelial sealing at the peri-implant collar. Histologically, epithelial sealing is recognized as the attachment of the basement membrane (BM). BM-attachment is promoted by activated platelet aggregates at surgical wound sites. On the other hand, platelets did not aggregate on smooth titanium, the surface typical of the implant abutment. We then hypothesized that epithelial BM-attachment was produced when titanium surface was modified to allow platelet aggregation. Titanium surfaces were coated with a protease activated receptor 4-activating peptide (PAR4-AP). PAR4-AP coating yielded rapid aggregation of platelets on the titanium surface. Platelet aggregates released robust amount of epithelial chemoattractants (IGF-I, TGF-β) and growth factors (EGF, VEGF) on the titanium surface. Human gingival epithelial cells, when they were co-cultured on the platelet aggregates, successfully attached to the PAR4-AP coated titanium surface with spread laminin5 positive BM and consecutive staining of the epithelial tight junction component ZO1, indicating the formation of complete epithelial sheet. These in-vitro results indicate the establishment of epithelial BM-attachment to the titanium surface. PMID:27741287
Bloemen-van Gurp, Esther J; Murrer, Lars H P; Haanstra, Björk K C; van Gils, Francis C J M; Dekker, Andre L A J; Mijnheer, Ben J; Lambin, Philippe
2009-01-01
In vivo dosimetry during brachytherapy of the prostate with (125)I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% +/- 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. MOSFET detectors are suitable for in vivo dosimetry during (125)I brachytherapy of prostate cancer. An action level of +/- 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.
Brachytherapy in early prostate cancer--early experience.
Jose, B O; Bailen, J L; Albrink, F H; Steinbock, G S; Cornett, M S; Benson, D C; Schmied, W K; Medley, R N; Spanos, W J; Paris, K J; Koerner, P D; Gatenby, R A; Wilson, D L; Meyer, R
1999-01-01
Use of brachytherapy with radioactive seeds in the management of early prostate cancer is commonly used in the United States. The early experience has been reported from the prostate treatment centers in Seattle for the last 10 years. In this manuscript we are reporting our early experience of 150 radioactive seed implantations in early stage prostate cancer using either Iodine 125 or Palladium 103 seeds. The average age of the patient is 66 years and the median Gleason score is 5.4 with a median PSA of 6. A brief description of the evolution of the treatment of prostate cancer as well as the preparation for the seed implantation using the volume study with ultrasound of the prostate, pubic arch study using CT scan of the pelvis and the complete planning using the treatment planning computers are discussed. We also have described the current technique which is used in our experience based on the Seattle guidelines. We plan a follow-up report with the results of the studies with longer follow-up.
Nag, Subir; Demanes, D Jeffrey; Hagan, Michael; Rivard, Mark J; Thomadsen, Bruce R; Welsh, James S; Williamson, Jeffrey F
2011-10-01
The Nuclear Regulatory Commission deems it to be a medical event (ME) if the total dose delivered differs from the prescribed dose by 20% or more. A dose-based definition of ME is not appropriate for permanent prostate brachytherapy as it generates too many spurious MEs and thereby creates unnecessary apprehension in patients, and ties up regulatory bodies and the licensees in unnecessary and burdensome investigations. A more suitable definition of ME is required for permanent prostate brachytherapy. The American Society for Radiation Oncology (ASTRO) formed a working group of experienced clinicians to review the literature, assess the validity of current regulations, and make specific recommendations about the definition of an ME in permanent prostate brachytherapy. The working group found that the current definition of ME in §35.3045 as "the total dose delivered differs from the prescribed dose by 20 percent or more" was not suitable for permanent prostate brachytherapy since the prostate volume (and hence the resultant calculated prostate dose) is dependent on the timing of the imaging, the imaging modality used, the observer variability in prostate contouring, the planning margins used, inadequacies of brachytherapy treatment planning systems to calculate tissue doses, and seed migration within and outside the prostate. If a dose-based definition for permanent implants is applied strictly, many properly executed implants would be improperly classified as an ME leading to a detrimental effect on brachytherapy. The working group found that a source strength-based criterion, of >20% of source strength prescribed in the post-procedure written directive being implanted outside the planning target volume is more appropriate for defining ME in permanent prostate brachytherapy. ASTRO recommends that the definition of ME for permanent prostate brachytherapy should not be dose based but should be based upon the source strength (air-kerma strength) administered.
The Royal College of Radiologists' audit of prostate brachytherapy in the year 2012.
Stewart, A J; Drinkwater, K J; Laing, R W; Nobes, J P; Locke, I
2015-06-01
This audit provides a comprehensive overview of UK prostate brachytherapy practice in the year 2012, measured against existing standards, immediately before the introduction of new Royal College of Radiologists (RCR) guidelines. This audit allows comparison with European and North American brachytherapy practice and for the impact of the RCR 2012 guidelines to be assessed in the future. A web-based data collection tool was developed by the RCR Clinical Audit Committee and sent to audit leads at all cancer centres in the UK. Standards were developed based on available guidelines in use at the start of 2012 covering case mix and dosimetry. Further questions were included to reflect areas of anticipated change with the implementation of the 2012 guidelines. Audit findings were compared with similar audits of practice in Europe, the USA and Latin America. Forty-nine of 59 cancer centres submitted data. Twenty-nine centres reported carrying out prostate brachytherapy; of these, 25 (86%) provided data regarding the number of implants, staffing, dosimetry, medication and anaesthesia and follow-up. Audit standards achieved excellent compliance in most areas, although were low in post-implant dosimetry and in post-implant scanning at 30 days. This audit provides a comprehensive picture of prostate brachytherapy in the UK in 2012. Patterns of care of prostate brachytherapy are similar to practice in the USA and Europe. The number of prostate brachytherapy implants carried out in the UK has grown significantly since a previous RCR audit in 2005 and it is important that centres maintain minimum numbers of cases to ensure that experience can be maintained and compliance to guidelines achieved. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Benzaquen, David; Delouya, Guila; Ménard, Cynthia; Barkati, Maroie; Taussky, Daniel
In prostate seed brachytherapy, a D 90 of <130 Gy is an accepted predictive factor for biochemical failure (BF). We studied whether there is a subpopulation that does not need additional treatment after a suboptimal permanent seed brachytherapy implantation. A total of 486 patients who had either BF or a minimum followup of 48 months without BF were identified. BF was defined according to the Phoenix definition (nadir prostate-specific antigen + 2). Univariate and multivariate analyses were performed, adjusting for known prognostic factors such as D 90 and prostate-specific antigen density (PSAD) of ≥0.15 ng/mL/cm 3 , to evaluate their ability to predict BF. Median followup for patients without BF was 72 months (interquartile range 56-96). BF-free recurrence rate at 5 years was 95% and at 8 years 88%. In univariate analysis, PSAD and cancer of the prostate risk assessment score were predictive of BF. On multivariate analysis, none of the factors remained significant. The best prognosis had patients with a low PSAD (<0.15 ng/mL/cm 3 ) and an optimal implant at 30 days after implantation (as defined by D 90 ≥ 130 Gy) compared to patients with both factors unfavorable (p = 0.006). A favorable PSAD was associate with a good prognosis, independently of the D 90 (<130 Gy vs. ≥130 Gy, p = 0.7). Patients with a PSAD of <0.15 ng/mL/cm 3 have little risk of BF, even in the case of a suboptimal implant. These results need to be validated in other patients' cohorts. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Radioactive iodine-125 implantation for cancer of the prostate.
Nag, S
1985-01-01
Localized cancer of the prostate can be treated by radical prostatectomy, external beam irradiation, or radioactive implantation with similar survival results. Radical prostatectomy, however, almost universally results in impotency, although a new, nerve-sparing procedure may preserve potency in B1 patients. External beam irradiation radiates a large volume of tissue with significant rectal and bladder morbidity, 23-47% risk of impotency, and requires prolonged treatment (6-8 weeks). Radioactive implantation may be done suprapubically or transperineally using iodine-125, gold-198, or radon-222 permanent implantation techniques and iridium-192 or radium-226 removable implantation techniques. Interstitial iodine-125 implantation is frequently employed since it is a short procedure and limits the morbidity to a 7% incidence of impotency, 20% urinary complications, and 5% rectal complications. The overall 5-year survival of patients with iodine-125 is 79%, the survival rate decreasing with increasing T or N stage or increasing grade of tumor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilkinson, D; Kolar, M
Purpose: To analyze the application of volume implant (V100) data as a method for a global check of low dose rate (LDR) brachytherapy plans. Methods: Treatment plans for 335 consecutive patients undergoing permanent seed implants for prostate cancer and for 113 patients treated with plaque therapy for ocular melanoma were analyzed. Plaques used were 54 COMS (10 to 20 mm, notched and regular) and 59 Eye Physics EP917s with variable loading. Plots of treatment time x implanted activity per unit dose versus v100 ^.667 were made. V100 values were obtained using dose volume histograms calculated by the treatment planning systemsmore » (Variseed 8.02 and Plaque Simulator 5.4). Four different physicists were involved in planning the prostate seed cases; two physicists for the eye plaques. Results: Since the time and dose for the prostate cases did not vary, a plot of implanted activity vs V100 ^.667 was made. A linear fit with no intercept had an r{sup 2} = 0.978; more than 94% of the actual activities fell within 5% of the activities calculated from the linear fit. The greatest deviations were in cases where the implant volumes were large (> 100 cc). Both COMS and EP917 plaque linear fits were good (r{sup 2} = .967 and .957); the largest deviations were seen for large volumes. Conclusions: The method outlined here is effective for checking planning consistency and quality assurance of two types of LDR brachytherapy treatment plans (temporary and permanent). A spreadsheet for the calculations enables a quick check of the plan in situations were time is short (e.g. OR-based prostate planning)« less
NASA Astrophysics Data System (ADS)
Li, X. Allen; Wang, Jian Z.; Stewart, Robert D.; Di Biase, Steven J.
2003-09-01
No prospective dose escalation study for prostate brachytherapy (PB) with permanent implants has been reported. In this work, we have performed a dosimetric and biological analysis to explore the implications of dose escalation in PB using 125I and 103Pd implants. The concept of equivalent uniform dose (EUD), proposed originally for external-beam radiotherapy (EBRT), is applied to low dose rate brachytherapy. For a given 125I or 103Pd PB, the EUD for tumour that corresponds to a dose distribution delivered by EBRT is calculated based on the linear quadratic model. The EUD calculation is based on the dose volume histogram (DVH) obtained retrospectively from representative actual patient data. Tumour control probabilities (TCPs) are also determined in order to compare the relative effectiveness of different dose levels. The EUD for normal tissue is computed using the Lyman model. A commercial inverse treatment planning algorithm is used to investigate the feasibility of escalating the dose to prostate with acceptable dose increases in the rectum and urethra. The dosimetric calculation is performed for five representative patients with different prostate sizes. A series of PB dose levels are considered for each patient using 125I and 103Pd seeds. It is found that the PB prescribed doses (minimum peripheral dose) that give an equivalent EBRT dose of 64.8, 70.2, 75.6 and 81 Gy with a fraction size of 1.8 Gy are 129, 139, 150 and 161 Gy for 125I and 103, 112, 122 and 132 Gy for 103Pd implants, respectively. Estimates of the EUD and TCP for a series of possible prescribed dose levels (e.g., 145, 160, 170 and 180 Gy for 125I and 125, 135, 145 and 155 for 103Pd implants) are tabulated. The EUD calculation was found to depend strongly on DVHs and radiobiological parameters. The dosimetric calculations suggest that the dose to prostate can be escalated without a substantial increase in both rectal and urethral dose. For example, increasing the PB prescribed dose from 145 to 180 Gy increases EUD for the rectum by only 3%. Our studies indicate that the dose to urethra can be kept within 100-120% of the prescription dose for all the dose levels studied. In conclusion, dose escalation in permanent implant for localized prostate cancer may be advantageous. It is dosimetrically possible to increase dose to prostate without a substantial increase in the dose to the rectum and urethra. Based on the results of our studies, a prospective dose escalation trial for prostate permanent implants has been initiated at our institution.
Long-Term Outcomes of Alternative Brachytherapy Techniques for Early Prostate Cancer
2007-01-01
Oncol 2003;21:3979-86. 15. Whitmore WF, Jr., Hilaris B, Grabstald H. Retropubic implantation to iodine 125 in the treatment of prostatic cancer. J...brachytherapy and external beam irradiation for clinically localized, high-risk prostatic carcinoma. Int J Radiat Oncol Biol Phys 1996;35:875-9. 29. Stock RG
Brachytherapy for Prostate Cancer: A Systematic Review
Koukourakis, Georgios; Kelekis, Nikolaos; Armonis, Vassilios; Kouloulias, Vassilios
2009-01-01
Low-dose rate brachytherapy has become a mainstream treatment option for men diagnosed with prostate cancer because of excellent long-term treatment outcomes in low-, intermediate-, and high-risk patients. To a great extend due to patient lead advocacy for minimally invasive treatment options, high-quality prostate implants have become widely available in the US, Europe, and Japan. High-dose-rate (HDR) afterloading brachytherapy in the management of localised prostate cancer has practical, physical, and biological advantages over low-dose-rate seed brachytherapy. There are no free live sources used, no risk of source loss, and since the implant is a temporary procedure following discharge no issues with regard to radioprotection use of existing facilities exist. Patients with localized prostate cancer may benefit from high-dose-rate brachytherapy, which may be used alone in certain circumstances or in combination with external-beam radiotherapy in other settings. The purpose of this paper is to present the essentials of brachytherapies techniques along with the most important studies that support their effectiveness in the treatment of prostate cancer. PMID:19730753
SU-C-17A-02: Sirius MRI Markers for Prostate Post-Implant Assessment: MR Protocol Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, T; Wang, J; Kudchadker, R
Purpose: Currently, CT is used to visualize prostate brachytherapy sources, at the expense of accurate structure contouring. MRI is superior to CT for anatomical delineation, but the sources appear as voids on MRI images. Previously we have developed Sirius MRI markers (C4 Imaging) to replace spacers to assist source localization on MRI images. Here we develop an MRI pulse sequence protocol that enhances the signal of these markers to enable MRI-only post-implant prostate dosimetric analysis. Methods: To simulate a clinical scenario, a CIRS multi-modality prostate phantom was implanted with 66 markers and 86 sources. The implanted phantom was imaged onmore » both 1.5T and 3.0T GE scanners under various conditions, different pulse sequences (2D fast spin echo [FSE], 3D balanced steadystate free precession [bSSFP] and 3D fast spoiled gradient echo [FSPGR]), as well as varying amount of padding to simulate various patient sizes and associated signal fall-off from the surface coil elements. Standard FSE sequences from the current clinical protocols were also evaluated. Marker visibility, marker size, intra-marker distance, total scan time and artifacts were evaluated for various combinations of echo time, repetition time, flip angle, number of excitations, bandwidth, slice thickness and spacing, fieldof- view, frequency/phase encoding steps and frequency direction. Results: We have developed a 3D FSPGR pulse sequence that enhances marker signal and ensures the integrity of the marker shape while maintaining reasonable scan time. For patients contraindicated for 3.0T, we have also developed a similar sequence for 1.5T scanners. Signal fall-off with distance from prostate to coil can be compensated mainly by decreasing bandwidth. The markers are not visible using standard FSE sequences. FSPGR sequences are more robust for consistent marker visualization as compared to bSSFP sequences. Conclusion: The developed MRI pulse sequence protocol for Sirius MRI markers assists source localization to enable MRIonly post-implant prostate dosimetric analysis. S.J. Frank is a co-founder of C4 Imaging (manufactures the MRI markers)« less
Role of step size and max dwell time in anatomy based inverse optimization for prostate implants
Manikandan, Arjunan; Sarkar, Biplab; Rajendran, Vivek Thirupathur; King, Paul R.; Sresty, N.V. Madhusudhana; Holla, Ragavendra; Kotur, Sachin; Nadendla, Sujatha
2013-01-01
In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source. In total, one hundred inverse treatment plans were generated for the four patients included in this study. Twenty-five treatment plans were created for each patient by varying the step size and maximum source dwell time during anatomy-based, inverse-planned optimization. Other relevant treatment planning parameters were kept constant, including the dose constraints and source dwell positions. Each plan was evaluated for target coverage, urethral and rectal dose sparing, treatment time, relative target dose homogeneity, and nonuniformity ratio. The plans with 0.5 cm step size were seen to have clinically acceptable tumor coverage, minimal normal structure doses, and minimum treatment time as compared with the other step sizes. The target coverage for this step size is 87% of the prescription dose, while the urethral and maximum rectal doses were 107.3 and 68.7%, respectively. No appreciable difference in plan quality was observed with variation in maximum source dwell time. The step size plays a significant role in plan optimization for prostate implants. Our study supports use of a 0.5 cm step size for prostate implants. PMID:24049323
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawton, Colleen A., E-mail: clawton@mcw.edu; Hunt, Daniel; Lee, W. Robert
2011-09-01
Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to themore » prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable generalizability of the outcomes.« less
Mason, J; Al-Qaisieh, B; Bownes, P; Henry, A; Thwaites, D
2013-03-01
In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k = 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). ISA causes the delivered dose in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.
The Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening Trial Etiologic and Early Marker Studies (EEMS) has a new application process for specimen requests. Researchers planning to submit a grant application in response to the Funding Opportunity Announcement PAR-15-297 must use a new website to submit applications. |
NASA Astrophysics Data System (ADS)
Lequoy, Pauline
Malgre des avancees technologiques indeniables, l'efficacite des implants biomedicaux est encore limitee par les biomateriaux synthetiques qui les composent, notamment en raison de leur incapacite a generer une reponse biologique adequate. En particulier, la guerison tissulaire autour des implants vasculaires reste problematique. Une etude de la litterature a montre que dans le cas des endoprotheses couvertes (tuyaux polymeriques utilises pour la reparation endovasculaire des anevrismes de l'aorte abdominale), le manque de guerison observe s'explique non seulement par l'inertie des biomateriaux utilises mais aussi par le fait que l'implant est insere dans un vaisseau malade favorisant la mort des cellules par apoptose et presentant une depletion cellulaire marquee. L'hypothese a la base de ce projet est qu'un revetement bioactif pourrait ameliorer la guerison et la colonisation de l'implant par les cellules vasculaires et ainsi favoriser l'attachement de l'implant dans le vaisseau malade afin de prevenir les complications a long terme. Dans ce contexte, deux molecules anti-apoptotiques ont ete selectionnees pour developper le revetement, la chondroitine sulfate (CS), un glycosaminoglycane de la matrice extracellulaire, et le facteur de croissance de l'epiderme (EGF) qui possede egalement un role important dans la guerison tissulaire. L'un des defis de ce projet est de preserver la bioactivite de ces molecules lors de leur immobilisation dans un revetement. Pour etablir une preuve de concept, nous avons demontre qu'un revetement CS+EGF obtenu par greffage covalent permet d'ameliorer significativement la survie des cellules vasculaires humaines (cellules musculaires lisses, CMLV, et fibroblastes) sur les materiaux realistes (PET, ePTFE). Apres avoir transfere ce revetement sur des implants commerciaux en ePTFE, des tests in vivo ont demontre une amelioration de la guerison grâce au revetement bioactif, cependant la guerison n'a pas ete totale dans la cavite anevrismale. Pour ameliorer la bioactivite du revetement, un systeme de capture oriente base sur la complementarite de deux peptides (superhelices 'coiled-coil') a ete utilise pour immobiliser l'EGF sur CS. Cette immobilisation orientee a permis une meilleure efficacite de capture, ainsi qu'une augmentation marquee de la survie des CMLV par rapport au greffage covalent aleatoire utilise precedemment. De plus, les travaux realises ont permis l'avancement de la comprehension des proprietes antiadhesives selectives de CS par comparaison avec le dextrane carboxymethyle. Enfin, nous avons demontre que la polyvalence du systeme de capture oriente pour facteurs de croissance permet la co-immobilisation de deux facteurs de croissance, EGF et VEGF (facteur de croissance de l'endothelium vasculaire), et ce a des ratios variables. Les densites surfaciques ont ete optimisees par simple changement de concentration lors de l'incubation. Des etudes cellulaires avec une gamme de ratios EGF/VEGF ont revele un effet synergique des deux facteurs de croissance sur la survie des CMLV et des cellules endotheliales. Les travaux menes ont permis de developper des revetements bioactifs anti-apoptotiques qui ameliorent la survie des cellules vasculaires et constituent une avancee vers la creation d'endoprotheses bioactives. Il apparait egalement que la plateforme d'immobilisation coiled-coil presente un grand potentiel pour la construction de surfaces bioactives complexes et la comprehension du role de differents facteurs de croissance dans les comportements cellulaires.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sahgal, Arjun; Department of Radiation Oncology, Odette Cancer Centre at Sunnybrook Hospital, University of Toronto, Toronto, ON; Jabbari, Siavash
2008-09-01
Purpose: To compare the urethral and prostate absolute and biologic effective doses (BEDs) for {sup 131}Cs and {sup 125}I prostate permanent implant brachytherapy (PPI). Methods and Materials: Eight previously implanted manually planned {sup 125}I PPI patients were replanned manually with {sup 131}Cs, and re-planned using Inverse Planning Simulated Annealing. {sup 131}Cs activity and the prescribed dose (115 Gy) were determined from that recommended by IsoRay. The BED was calculated for the prostate and urethra using an {alpha}/{beta} ratio of 2 and was also calculated for the prostate using an {alpha}/{beta} ratio of 6 and a urethral {alpha}/{beta} ratio of 2.more » The primary endpoints of this study were the prostate D{sub 90} BED (pD{sub 90}BED) and urethral D{sub 30} BED normalized to the maximal potential prostate D{sub 90} BED (nuD{sub 30}BED). Results: The manual plan comparison ({alpha}/{beta} = 2) yielded no significant difference in the prostate D{sub 90} BED (median, 192 Gy{sub 2} for both isotopes). No significant difference was observed for the nuD{sub 30}BED (median, 199 Gy{sub 2} and 202 Gy{sub 2} for {sup 125}I and {sup 131}Cs, respectively). For the inverse planning simulated annealing plan comparisons ({alpha}/{beta} 2), the prostate D{sub 90} BED was significantly lower with {sup 131}Cs than with {sup 125}I (median, 177 Gy{sub 2} vs. 187 Gy{sub 2}, respectively; p = 0.01). However, the nuD{sub 30}BED was significantly greater with {sup 131}Cs than with {sup 125}I (median, 192 Gy{sub 2} vs. 189 Gy{sub 2}, respectively; p = 0.01). Both the manual and the inverse planning simulated annealing plans resulted in a significantly lower prostate D{sub 90} BED (p = 0.01) and significantly greater nuD{sub 30}BED for {sup 131}Cs (p = 0.01), compared with {sup 125}I, when the prostate {alpha}/{beta} ratio was 6 and the urethral {alpha}/{beta} ratio was 2. Conclusion: This report highlights the controversy in comparing the dose to both the prostate and the organs at risk with different radionuclides.« less
Prostate Bed Motion During Intensity-Modulated Radiotherapy Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klayton, Tracy; Price, Robert; Buyyounouski, Mark K.
Purpose: Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders. Methods and Materials: The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center. Results: At localization, prostate bedmore » displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the anterior-posterior (A-P) direction and 21% of fractions in the superior-inferior (S-I) direction. The three-dimensional vector length from skin marks to Calypso alignment exceeded 1 cm in 24% of all 652 fractions with available setup data. During treatment, the target exceeded the 5-mm tracking limit for at least 30 sec in 11% of all fractions, generally in the A-P or S-I direction. In the A-P direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly. Fifteen percent of all treatments were interrupted for repositioning, and 70% of patients were repositioned at least once during their treatment course. Conclusion: Set-up errors and motion of the prostatic fossa during radiotherapy are nontrivial, leading to potential undertreatment of target and excess normal tissue toxicity if not taken into account during treatment planning. Localization and real-time tracking of the prostate bed via implanted Calypso transponders can be used to improve the accuracy of plan delivery.« less
2005-10-01
salvage seed implant, cryotherapy ) or who have a rising PSA while on hormone therapy for locally advanced prostate cancer are as follows: a. A...Gene Transduction in Patients with Recurrent Locally Advanced Prostate Cancer Following Therapy PRINCIPAL INVESTIGATOR: Simon J. Hall, MD...CONTRACT NUMBER Phase I Trial of Adenovirus-Mediated IL-12 Gene Transduction in Patients with Recurrent Locally Advanced Prostate Cancer Following
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, P; Wang, L; Riegel, A
Purpose: Several nomograms exist for the purpose of ordering palladium- 103 seeds for permanent prostate seed implants. Excess seeds pose additional radiation safety risks and increase the cost of care. This study compared three seed ordering nomograms with seed counts from dynamic intra-operative PSI to determine (1) the cause of excess seeds and (2) the optimal nomogram for our institution. Methods: Pre-operative and intra-operative clinical data were collected for 100 Gy (n=151) and 125 Gy (n=224) prostate seed implants. The number of implanted seeds which would have given D90=100% was normalized to that criteria and seed strength of 2U. Thismore » was plotted against intra-operative prostate volume and compared to two previously published nomograms and an in-house nomogram. A linear fit was produced and confidence intervals were calculated. The causes of excess seeds were assessed by comparing pre- and intra-operative prostate volumes, variability of D90 around 100%, and variance of seed strength from 2U. Results: Of the 375 total cases, 97.6% had excess seeds. On average, 27.17±12.91% of ordered seeds were wasted. Of this percentage, 6.98±5.47% of excess seeds were due to overestimation of pre-operative prostate volume, 1.10±0.88% were due to D90<100%, 1.17±0.67% were due to seed strength over 2U, and 17.36±7.79% could not be directly attributed to a specific reason. The latter percentage may be due to overestimation of the in-house nomogram. Two of three nomograms substantially overestimated the number of seeds required. The third nomogram underestimated the required seed number for smaller prostate treatment volume. A linear fit to the clinical data was derived and 99.9% confidence intervals were calculated. Conclusion: Over 85% of clinical cases wasted over 15% of ordered seeds. Two of three nomograms overestimated the required number of seeds. The upper 99.9% C.I. of the clinical data may provide a more reasonable nomogram for Pd-103 seed ordering.« less
A novel curvilinear approach for prostate seed implantation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podder, Tarun K.; Dicker, Adam P.; Hutapea, Parsaoran
Purpose: A new technique called ''curvilinear approach'' for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. Methods: Twenty LDR prostate brachytherapy cases planned intraoperatively with VariSeed planning system and I-125 seeds were randomly selected as reference rectilinear cases. All the cases were replanned by using curved-needle approach keeping the same individual source strength and the volume receiving 100% of prescribed dose 145 Gy (V{sub 100}). Parameters such as number of needles, seeds, and the dose coverage of the prostate (D{sub 90},more » V{sub 150}, V{sub 200}), urethra (D{sub 30}, D{sub 10}) and rectum (D{sub 5}, V{sub 100}) were compared for the rectilinear and the curvilinear methods. Statistical significance was assessed using two-tailed student's t-test. Results: Reduction of the required number of needles and seeds in curvilinear method were 30.5% (p < 0.001) and 11.8% (p < 0.49), respectively. Dose to the urethra was reduced significantly; D{sub 30} reduced by 10.1% (p < 0.01) and D{sub 10} reduced by 9.9% (p < 0.02). Reduction in rectum dose D{sub 5} was 18.5% (p < 0.03) and V{sub 100} was also reduced from 0.93 cc in rectilinear to 0.21 cc in curvilinear (p < 0.001). Also the V{sub 150} and V{sub 200} coverage of prostate reduced by 18.8% (p < 0.01) and 33.9% (p < 0.001), respectively. Conclusions: Significant improvement in the relevant dosimetric parameters was observed in curvilinear needle approach. Prostate dose homogeneity (V{sub 150}, V{sub 200}) improved while urethral dose was reduced, which might potentially result in better treatment outcome. Reduction in rectal dose could potentially reduce rectal toxicity and complications. Reduction in number of needles would minimize edema and thereby could improve postimplant urinary incontinence. This study indicates that the curvilinear implantation approach is dosimetrically superior to conventional rectilinear implantation technique.« less
Prostate implant nomograms for the North American scientific {sup 103}Pd seed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Jay J.; Stevens, Ritchie N
Palladium-103-({sup 103}Pd) seed has been increasingly used in prostate implantation as either definitive or boost therapy because of its shorter half-life and higher initial dose rate. Because a growing number of radiation oncologists prefer real-time implantation in the operating room, it will be helpful if the total activity of the seeds can be determined based on the gland size before the patient is taken to the operating room. Based on our clinic data, nomograms have therefore been developed for one of the widely used {sup 103}Pd seeds, the MED3633 seed, which is produced by North American Scientific, Inc. (NASI). Themore » total activities for implant volume ranging from 15 cc to 55 cc are provided for both seed 'monotherapy' and seed boost.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleinberg, L.; Wallner, K.; Roy, J.
The purpose was to summarize the urinary, rectal, and sexual symptoms occurring during the first 12 months following [sup 125]I prostatic implantation. Thirty-one patients with Stage T[sub 1] or T[sub 2] prostatic carcinoma were evaluate for morbidity following computed tomography-guided transperineal [sup 125]I implants from 1988 to 1991. The median total activity used was 47 mCi (range 35-37 mCi). Toxicity was evaluated using a modification of the Radiation Therapy Oncology Group grading system. Nocturia was the most common treatment-related symptom, reported by 80% of patients within 2 months after implantation, and persisted at 12 months in 45% of the patients.more » Mild dysuria developed in 48% of patients within 2 months of implantation; two patients needed analgesics for their dysuria. Terazosin hydrochloride (2-10 mg qd) provided subjective improvement of urinary symptoms in seven of eight patients in whom it was tried. Rectal urgency, soft stools, and increased frequency of bowel movements was reported by 25% of the patients within 1-2 months after implantation. The incidence of assymptomatic rectal bleeding or ulceration occurring at any time after implantation was 47%, but resolved in all patients with expectant treatment. Self-limiting ulceration of the rectal mucosal occurred in 16%, but only one patient developed a prostato-rectal fistula, managed with an ileal conduit. Five of the 18 potent patients experienced discomfort on erection or ejaculation, beginning within several weeks of their implant. The discomfort resolved within 6 months in three of the patients, but persisted for 18 and 24 months in the other two. [sup 125]I implantation, as performed in this series, is generally associated with only mild-moderate genitourinary and rectal symptoms that may persist 6 months or more after implantation. 16 refs., 6 figs., 2 tabs.« less
Photoacoustic imaging of prostate brachytherapy seeds with transurethral light delivery
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.
2014-03-01
We present a novel approach to photoacoustic imaging of prostate brachytherapy seeds utilizing an existing urinary catheter for transurethral light delivery. Two canine prostates were surgically implanted with brachyther- apy seeds under transrectal ultrasound guidance. One prostate was excised shortly after euthanasia and fixed in gelatin. The second prostate was imaged in the native tissue environment shortly after euthanasia. A urinary catheter was inserted in the urethra of each prostate. A 1-mm core diameter optical fiber coupled to a 1064 nm Nd:YAG laser was inserted into the urinary catheter. Light from the fiber was either directed mostly parallel to the fiber axis (i.e. end-fire fire) or mostly 90° to the fiber axis (i.e. side-fire fiber). An Ultrasonix SonixTouch scanner, transrectal ultrasound probe with curvilinear (BPC8-4) and linear (BPL9-5) arrays, and DAQ unit were utilized for synchronized laser light emission and photoacoustic signal acquisition. The implanted brachytherapy seeds were visualized at radial distances of 6-16 mm from the catheter. Multiple brachytherapy seeds were si- multaneously visualized with each array of the transrectal probe using both delay-and-sum (DAS) and short-lag spatial coherence (SLSC) beamforming. This work is the first to demonstrate the feasibility of photoacoustic imaging of prostate brachytherapy seeds using a transurethral light delivery method.
NASA Astrophysics Data System (ADS)
Moliton, A.; Ratier, B.; Moreau, C.; Froyer, G.
1991-05-01
In this paper, we present an automatized system for simultaneous measurement of conductivity σ, and thermoelectric power S : measurements are allowed for temperatures ranging from 130 K to 360 K on brittle semiconductor layers. As an example of the application, results obtained in the case of polymer (PPP) layers implanted with Na ions are presented : with high energy implantation (E = 250 keV) we observe only a defect semiconduction of p type while at low energy (30 keV) an electronic n type conduction appears. Nous présentons dans cet article un système de mesure simultanée de la conductivité σ, et du pouvoir thermoélectrique S : il permet des mesures en fonction de la température (entre 130 K et 360 K) dans le cas de couches semi-conductrices relativement fragiles. A titre d'application, nous indiquons les résultats que nous avons obtenus dans le cas de couches polymères (PPP) implantées avec des ions sodium: alors que seule une semi-conduction par défaut est générée par de fortes énergies d'implantation (E = 250 keV ), il apparaît une semiconduction induite par le dopage n lors d'implantations à basse énergie (E = 30 keV ).
Lichius, J J; Renneberg, H; Blaschek, W; Aumüller, G; Muth, C
1999-10-01
Direct implanting of fetal urogenital sinus (UGS) tissue into the ventral prostate gland of adult mice led to a 4-fold weight increase of the manipulated prostatic lobe. The induced growth could be reduced by the polysaccharide fraction (POLY-M) of the 20% methanolic extract of stinging nettle roots by 33.8%.
Hsu, Anna; Bruno, Richard S.; Löhr, Christiane V.; Taylor, Alan W.; Dashwood, Rodrick H.; Bray, Tammy M.; Ho, Emily
2010-01-01
Chronic inflammation and nuclear factor-kappa B (NFκB) have been implicated in prostate cancer development; thus, dietary factors that inhibit NFκB may serve as effective chemo-preventative agents. Prostate cancer risk is significantly lower in Asian countries compared to the US, which has prompted interest in the potential chemopreventative action of Asian dietary components such as soy and green tea. This study examined the effects of dietary soy and tea on NFκB activation and inflammation in vivo using a hormone-induced rat model for prostate cancer. Male Noble rats implanted with estradiol and testosterone were divided into 4 dietary groups: control, soy, tea, or soy+ tea. NFκB activation and inflammatory cytokines were measured post implantation. The combination of soy and tea suppressed NFκB p50 binding activity and protein levels via induction of IκBα. Soy and tea also decreased prostate inflammatory infiltration, increased Bax/BcL2 ratio, and decreased protein expression of TNFα, IL-6 and IL1-β compared to control. Soy and tea attenuated prostate malignancy by decreasing prostate hyperplasia. These effects were not apparent in groups treated with soy or tea alone. The ongoing in vivo studies thus far suggest that combination of foods, such as soy and tea, may inhibit hormone-induced pro-inflammatory NFκB signals that contribute to prostate cancer development. PMID:20801632
Maturation of the developing human fetal prostate in a rodent xenograft model
Saffarini, Camelia M.; McDonnell, Elizabeth V.; Amin, Ali; Spade, Daniel J.; Huse, Susan M.; Kostadinov, Stefan; Hall, Susan J.; Boekelheide, Kim
2015-01-01
Background Prostate cancer is the most commonly diagnosed non-skin cancer in men. The etiology of prostate cancer is unknown, although both animal and epidemiologic data suggest that early life exposures to various toxicants, may impact DNA methylation status during development, playing an important role. Methods We have developed a xenograft model to characterize the growth and differentiation of human fetal prostate implants (gestational age 12-24 weeks) that can provide new data on the potential role of early life stressors on prostate cancer. The expression of key immunohistochemical markers responsible for prostate maturation was evaluated, including p63, cytokeratin 18, α-smooth muscle actin, vimentin, caldesmon, Ki-67, prostate specific antigen, estrogen receptor-α, and androgen receptor. Xenografts were separated into epithelial and stromal compartments using laser capture microdissection (LCM), and the DNA methylation status was assessed in >480,000 CpG sites throughout the genome. Results Xenografts demonstrated growth and maturation throughout the 200 days of post-implantation evaluation. DNA methylation profiles of laser capture micro-dissected tissue demonstrated tissue-specific markers clustered by their location in either the epithelium or stroma of human prostate tissue. Differential methylated promoter region CpG-associated gene analysis revealed significantly more stromal than epithelial DNA methylation in the 30 and 90-day xenografts. Functional classification analysis identified CpG-related gene clusters in methylated epithelial and stromal human xenografts. Conclusion This study of human fetal prostate tissue establishes a xenograft model that demonstrates dynamic growth and maturation, allowing for future mechanistic studies of the developmental origins of later life proliferative prostate disease. PMID:24038131
SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petronek, M; Purysko, A; Balik, S
Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure bymore » a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.« less
Prostate cancer patients who have failed standard radiation therapy have the options of surgery, radioactive seed implantation or cryoablation. Deborah Citrin, M.D., of the Radiation Oncology Branch is leading a study of stereotactic body radiation therapy (SBRT) to treat prostate cancer that has recurred locally after standard radiation therapy. The goal of this study is to
SU-F-T-40: Can CBCT Images Be Used for Volume Studies of Prostate Seed Implants for Boost Treatment?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H; Lee, S; Diwanji, T
Purpose: In our clinic, the planning CT is used for definitive and boost low-dose-rate (LDR) brachytherapy treatments to determine the ultrasound volume in the operating room (OR) at the time of the implant. While the CT overestimation of OR volume is known, a larger estimation discrepancy has been observed for boost treatments. A possible reason is the prostate size reduction during EBRT for boost patients. Since cone-beam CT (CBCT) is often used as routine imaging guidance of EBRT, this prostate volume change may be captured. This study investigates if CBCT taken during EBRT includes the volume change information and thereforemore » beats CT in estimating the prostate OR volumes. Methods: 9 prostate patients treated with EBRT (45Gy in 1.8Gy per fractions to the whole pelvis) and I-125 seed implants (108Gy) were involved in this study. During EBRT, CBCT image guidance was performed on a weekly basis. For each patient, the prostate volumes on the first and the last available CBCT images were manually contoured by a physician. These volumes were then compared to each other and with the contoured volumes from the planning CT and from the ultrasound images in the OR. Results: The first and the last CBCT images did not show significant prostate volume change. Their average +/− standard deviation of prostate volumes were 24.4cc+/−14.6cc and 29.9cc+/−16.1cc, respectively (T-test p=0.68). The ratio of the OR volume to the last CBCT (0.71+/−0.21) was not significantly different from the ratio of OR volumes to the planning CT (0.61+/−0.13) (p=0.25). Conclusion: In this study, CBCT does not show significant prostate volume changes during EBRT. CBCT and CT volumes are quite consistent and no improvement of volume estimation using CBCT is observed. The advantage of CBCT as a replacement of CT for volume study of boost LDR brachytherapy is limited.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhen, H; Wu, Z; Bluemenfeld, P
Purpose Daily setup for definitive prostatic radiotherapy is challenged by suboptimal visibility of the prostate boundary and daily variation of rectum shape and position. For patients with improved bowel preparation, we conducted a dosimetric comparison between prostate implanted marker (IM)-based daily setup and anterior rectal wall (ARW)-based setup, with the hypothesis that the former leads to adequate target coverage with better rectal sparing. Methods Five IMRT/VMAT prostate cases with implanted markers were selected for analysis. Daily CBCT showed improvement of the rectal volume compared to planning CT. For each patient, the prostate and rectum were contoured on three CBCT imagesmore » (fraction 5/15/25) with subsequent physician review. The CBCTs were then registered to a planning CT using IM-based registration. The deviation of ARW positions from planning CT to CBCT were analyzed at various sup-inf levels (−1.8 cm to 1.8 cm from level of prostate center). To estimate the potential dosimetric impact from ARW-based setup, the treatment plans were recalculated using A-P shifts ranging from −1mm to +6mm. Clinically important rectum DVH values including Dmax, D3cc and Dmean were computed. Results For the studied patients, we observed on average 32% rectum volume reduction from planning CT to CBCT. As a Results, the ARW on average shifts posteriorly by −1mm to +5mm, depending on the sup-inf level of observation, with larger shifts observed at more superior levels. Recalculation shows that when ARW shifts 1mm posteriorly, ARW-based CBCT setup leads to a 1.0%, 4.2%, and 3.2% increase in rectum Dmax, D3cc, and Dmean, respectively, compared to IM-based setup. The dosimetric deviations increase to 4.7%, 25.8% and 24.7% when ARW shifts 6mm posteriorly. No significant prostate-only dose difference was observed. Conclusion For patients with improved bowel preparation, IM-based CBCT setup leads to accurate prostate coverage along with significantly lower rectal dose, compared to ARW-based setup.« less
[Orgasm after curietherapy with permanent iodine-125 radioimplants for localized prostate cancer].
Delaunay, B; Delannes, M; Salloum, A; Delavierre, D; Wagner, F; Jonca, F; Thoulouzan, M; Plante, P; Bachaud, J-M; Soulie, M; Huyghe, E
2011-12-01
Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy (125I permanent implantation), 241 (89%), mean age of 65 (43-80), participated in a mailed survey about sexual function after a mean time of 36 months (9-70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P=0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P=0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P=0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; P<0.001) after brachytherapy. Sixty patients (30.3%) experienced often/sometimes painful ejaculation 12.9% (n=31) before implantation (P=0.0001). Most of the patients treated by prostate brachytherapy conserved orgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Critz, F A; Williams, W H; Holladay, C T; Levinson, A K; Benton, J B; Holladay, D A; Schnell, F J; Maxa, L S; Shrake, P D
1999-12-01
The prostate-specific antigen (PSA) definition of disease freedom after radiotherapy for prostate cancer is still in dispute. This report focuses on the PSA nadir achieved in men treated by modern radiotherapy techniques. From 1984 to 1994, 489 consecutive men with clinical Stage T1 -T2 prostate cancer were treated by simultaneous radiation: prostate iodine-125 implant followed by external beam radiation. A transperineal implant was performed on 143 men with Stage T1-T2NX, the focus of this study; 346 men with Stage T1-T2N0 had a retropubic implant. The median pretreatment PSA was 8.3 ng/mL (range 0.3 to 188). A rising PSA was defined as one that rose on three consecutive occasions above whatever nadir was achieved. A minimum 5-year follow-up (range 5 to 15) was reached by 453 men. After a minimum 5-year follow-up, 336 men had a nonrising PSA, and of this group, 107 had undergone simultaneous radiation by the transperineal implant technique. A PSA nadir of 0.2 ng/mL or less was achieved by 97% of the transperineally implanted men, and 3% had a nadir of 0.3 to 1.0 ng/mL. Of the 489 men, those who had a nadir of 0.2 ng/mL or less had a 92% nonrising PSA rate (P = 0.001) 10 years after treatment compared with a 41% rate for men who had a nadir of 0.3 to 1.0 ng/mL. All men whose nadir was greater than 1.0 ng/mL had recurrence. The median time to achieve the PSA nadir of 0.2 ng/mL was 27 months (range 3 to 102). Primarily on the basis of the results from men treated with simultaneous radiation using the transperineal technique, the definition of disease freedom for radiotherapy should be men who achieve and maintain a PSA nadir of 0.2 ng/mL or less.
Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration
KarimAghaloo, Z.; Abolmaesumi, P.; Ahmidi, N.; Chen, T.K.; Gobbi, D. G.; Fichtinger, G.
2010-01-01
In prostate brachytherapy, a transrectal ultrasound (TRUS) will show the prostate boundary but not all the implanted seeds, while fluoroscopy will show all the seeds clearly but not the boundary. We propose an intensity-based registration between TRUS images and the implant reconstructed from uoroscopy as a means of achieving accurate intra-operative dosimetry. The TRUS images are first filtered and compounded, and then registered to the uoroscopy model via mutual information. A training phantom was implanted with 48 seeds and imaged. Various ultrasound filtering techniques were analyzed, and the best results were achieved with the Bayesian combination of adaptive thresholding, phase congruency, and compensation for the non-uniform ultrasound beam profile in the elevation and lateral directions. The average registration error between corresponding seeds relative to the ground truth was 0.78 mm. The effect of false positives and false negatives in ultrasound were investigated by masking true seeds in the uoroscopy volume or adding false seeds. The registration error remained below 1.01 mm when the false positive rate was 31%, and 0.96 mm when the false negative rate was 31%. This fully automated method delivers excellent registration accuracy and robustness in phantom studies, and promises to demonstrate clinically adequate performance on human data as well. Keywords: Prostate brachytherapy, Ultrasound, Fluoroscopy, Registration. PMID:21152376
Inflammation in Prostate Carcinogenesis: Role of the Tumor Suppressor Par-4
2012-09-01
2006; 2: 138–139. 112. Nezis IP, Simonsen A, Sagona AP, Finley K, Gaumer S, Contamine D et al. Ref(2)P, the Drosophila melanogaster homologue of...Tommerup N, Hansen C, Vissing H, Shi Y. Mapping of the human PAWR (par-4) gene to chromosome 12q21. Genomics 1998; 53:241-3. 17. Joshi J... The two aPKC isoforms are highly related, sharing an overall amino acid identity of 72%.1 The conservation in their sequences is most striking in the
Orthotopic tumorgrafts in nude mice: A new method to study human prostate cancer.
Saar, Matthias; Körbel, Christina; Linxweiler, Johannes; Jung, Volker; Kamradt, Jörn; Hasenfus, Andrea; Stöckle, Michael; Unteregger, Gerhard; Menger, Michael D
2015-10-01
In vivo model systems in prostate cancer research that authentically reproduce tumor growth are still sparse. While orthotopic implantation is technically difficult, particularly in the mouse, most models favor subcutaneous tumor growth. This however provides little information about natural tumor growth behavior and tumor stroma interaction. Furthermore, established prostate cancer cell lines grown as in vivo xenografts are not able to reflect the variety of tumor specific growth patterns and growth behavior in men. Primary cell cultures are difficult to handle and an induction of orthotopic tumors has not been successful yet. Therefore, a tumorgraft model using tumor tissue from prostatectomy specimens was developed. Balb/c nude mice were used to graft fresh prostate tumor tissue by renal subcapsular and orthotopic implantation. Testosterone propionate was supplemented. Animals were tracked by means of 30 MHz ultrasound to monitor tumor engraftment and growth. Autopsy, histology, PSA measurements as well as immunostaining and PCR for human tissue were performed to confirm orthotopic tumor growth. Renal subcapsular engraftment was seen in 2 of 3 mice. Orthotopic engraftment was observed in 7 of 11 animals (63.6%) with an overall engraftment of 5 out of 9 patient specimens (55.6%). Ultrasound confirmed the tumor growth over time. Of interest, the tumorgrafts not only retained essential features of the parental tumors, but also stained positive for tumor specific markers such as AR, PSA, and AMACR. Tumor positive animals showed highly elevated serum PSA levels with confirmation of a human specific PCR sequence and a human endothelial cell lining in the tumor vessels. Standardized implantation of fresh tumor tissue in nude mice prostates generates tumorgrafts with histological properties of organ-confined prostate cancer. These tumorgrafts display a new approach for an optimized in vivo model of prostate cancer and will allow further investigations on specific pathways of tumor initiation and progression as well as therapeutic response. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiraishi, Yutaka, E-mail: shiraishi@rad.med.keio.ac.jp; Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo; Yorozu, Atsunori
Purpose: To define the optimal dose for {sup 125}I prostate implants by correlating postimplantation dosimetry findings with biochemical failure and toxicity. Methods and Materials: Between 2003 and 2009, 683 patients with prostate cancer were treated with {sup 125}I prostate brachytherapy without supplemental external beam radiation therapy and were followed up for a median time of 80 months. Implant dose was defined as the D90 (the minimal dose received by 90% of the prostate) on postoperative day 1 and 1 month after implantation. Therefore, 2 dosimetric variables (day 1 D90 and day 30 D90) were analyzed for each patient. We investigated the dosemore » effects on biochemical control and toxicity. Results: The 7-year biochemical failure-free survival (BFFS) rate for the group overall was 96.4% according to the Phoenix definition. A multivariate analysis found day 1 D90 and day 30 D90 to be the most significant factors affecting BFFS. The cutoff points for day 1 D90 and day 30 D90, calculated from ROC curves, were 163 Gy and 175 Gy, respectively. By use of univariate analysis, various dosimetric cutoff points for day 30 D90 were tested. We found that day 30 D90 cutoff points from 130 to 180 Gy appeared to be good for the entire cohort. Greater D90s were associated with an increase in late genitourinary or gastrointestinal toxicity ≥ grade 2, but the increase was not statistically significant. Conclusions: Improvements in BFFS rates were seen with increasing D90 levels. Day 30 D90 doses of 130 to 180 Gy were found to serve as cutoff levels. For low-risk and low-tier intermediate-risk prostate cancer patients, high prostate D90s, even with doses exceeding 180 Gy, achieve better treatment results and are feasible.« less
Opoku-Acheampong, Alexander B.; Nelsen, Michelle K.; Unis, Dave; Lindshield, Brian L.
2012-01-01
Background 5α-reductase 1 (5αR1) and 5α-reductase 2 (5αR2) convert testosterone into the more potent androgen dihydrotestosterone. 5αR2 is the main isoenzyme in normal prostate tissue; however, most prostate tumors have increased 5αR1 and decreased 5αR2 expression. Previously, finasteride (5αR2 inhibitor) treatment begun 3 weeks post-tumor implantation had no effect on Dunning R3327-H rat prostate tumor growth. We believe the tumor compensated for finasteride treatment by increasing tumor 5αR1 expression or activity. We hypothesize that finasteride treatment would not significantly alter tumor growth even if begun before tumor implantation, whereas dutasteride (5αR1 and 5αR2 inhibitor) treatment would decrease tumor growth regardless of whether treatment was initiated before or after tumor implantation. Methodology/Principal Findings Sixty 8-week-old male nude mice were randomized to Control, Pre- and Post-Finasteride, and Pre- and Post-Dutasteride (83.3 mg drug/kg diet) diet groups. Pre- and post-groups began their treatment diets 1–2 weeks prior to or 3 weeks after subcutaneous injection of 1×105 WPE1-NA22 human prostate cancer cells, respectively. Tumors were allowed to grow for 22 weeks; tumor areas, body weights, and food intakes were measured weekly. At study's conclusion, prostate and seminal vesicle weights were significantly decreased in all treatment groups versus the control; dutasteride intake significantly decreased seminal vesicle weights compared to finasteride intake. No differences were measured in final tumor areas or tumor weights between groups, likely due to poor tumor growth. In follow-up studies, proliferation of WPE1-NA22 prostate cancer cells and parent line RWPE-1 prostate epithelial cells were unaltered by treatment with testosterone, dihydrotestosterone, or mibolerone, suggesting that these cell lines are not androgen-sensitive. Conclusion The lack of response of WPE1-NA22 prostate cancer cells to androgen treatment may explain the inadequate tumor growth observed. Additional studies are needed to determine whether finasteride and dutasteride are effective in decreasing prostate cancer development/growth. PMID:22242155
Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy.
Bonenfant, Éric; Magnoux, Vincent; Hissoiny, Sami; Ozell, Benoît; Beaulieu, Luc; Després, Philippe
2015-07-07
The aim of this study was to evaluate the potential of bGPUMCD, a Monte Carlo algorithm executed on Graphics Processing Units (GPUs), for fast dose calculations in permanent prostate implant dosimetry. It also aimed to validate a low dose rate brachytherapy source in terms of TG-43 metrics and to use this source to compute dose distributions for permanent prostate implant in very short times. The physics of bGPUMCD was reviewed and extended to include Rayleigh scattering and fluorescence from photoelectric interactions for all materials involved. The radial and anisotropy functions were obtained for the Nucletron SelectSeed in TG-43 conditions. These functions were compared to those found in the MD Anderson Imaging and Radiation Oncology Core brachytherapy source registry which are considered the TG-43 reference values. After appropriate calibration of the source, permanent prostate implant dose distributions were calculated for four patients and compared to an already validated Geant4 algorithm. The radial function calculated from bGPUMCD showed excellent agreement (differences within 1.3%) with TG-43 accepted values. The anisotropy functions at r = 1 cm and r = 4 cm were within 2% of TG-43 values for angles over 17.5°. For permanent prostate implants, Monte Carlo-based dose distributions with a statistical uncertainty of 1% or less for the target volume were obtained in 30 s or less for 1 × 1 × 1 mm(3) calculation grids. Dosimetric indices were very similar (within 2.7%) to those obtained with a validated, independent Monte Carlo code (Geant4) performing the calculations for the same cases in a much longer time (tens of minutes to more than a hour). bGPUMCD is a promising code that lets envision the use of Monte Carlo techniques in a clinical environment, with sub-minute execution times on a standard workstation. Future work will explore the use of this code with an inverse planning method to provide a complete Monte Carlo-based planning solution.
Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy
NASA Astrophysics Data System (ADS)
Bonenfant, Éric; Magnoux, Vincent; Hissoiny, Sami; Ozell, Benoît; Beaulieu, Luc; Després, Philippe
2015-07-01
The aim of this study was to evaluate the potential of bGPUMCD, a Monte Carlo algorithm executed on Graphics Processing Units (GPUs), for fast dose calculations in permanent prostate implant dosimetry. It also aimed to validate a low dose rate brachytherapy source in terms of TG-43 metrics and to use this source to compute dose distributions for permanent prostate implant in very short times. The physics of bGPUMCD was reviewed and extended to include Rayleigh scattering and fluorescence from photoelectric interactions for all materials involved. The radial and anisotropy functions were obtained for the Nucletron SelectSeed in TG-43 conditions. These functions were compared to those found in the MD Anderson Imaging and Radiation Oncology Core brachytherapy source registry which are considered the TG-43 reference values. After appropriate calibration of the source, permanent prostate implant dose distributions were calculated for four patients and compared to an already validated Geant4 algorithm. The radial function calculated from bGPUMCD showed excellent agreement (differences within 1.3%) with TG-43 accepted values. The anisotropy functions at r = 1 cm and r = 4 cm were within 2% of TG-43 values for angles over 17.5°. For permanent prostate implants, Monte Carlo-based dose distributions with a statistical uncertainty of 1% or less for the target volume were obtained in 30 s or less for 1 × 1 × 1 mm3 calculation grids. Dosimetric indices were very similar (within 2.7%) to those obtained with a validated, independent Monte Carlo code (Geant4) performing the calculations for the same cases in a much longer time (tens of minutes to more than a hour). bGPUMCD is a promising code that lets envision the use of Monte Carlo techniques in a clinical environment, with sub-minute execution times on a standard workstation. Future work will explore the use of this code with an inverse planning method to provide a complete Monte Carlo-based planning solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belz, J; Kumar, R; Sridhar, S
Purpose: We propose an innovative combinatorial treatment strategy of Local ChemoRadiation Therapy (LCRT) using a sustained drug delivery platform in the form of a spacer to locally radio-sensitize the prostate with Docetaxel (DTX) enabling a synergistic cure with the use of lower radiation doses. These biodegradable spacers are physically similar to the inert spacers routinely used in prostate brachytherapy but are now loaded with formulations of DTX. Methods: Spacers were loaded with ∼500µg Docetaxel (DTX) for prostate cancer studies. The implants were characterized in vitro using SEM and HPLC. The release kinetic studies were carried out in buffer (pH 6.0)more » at 37°C. Subcutaneous PC3 tumors were xenografted in nude mice. Prostate cancer studies were done with and without radiation using SARRP at 5Gy, 10Gy, and 15Gy. Drug-loaded implants were injected once intratumorally using an 18G brachytherapy needle. Results: The release study in vitro showed a highly sustained release for multiple weeks at therapeutically relevant doses. The monotherapy with local DTX spacer showed sustained tumor inhibition compared to empty implants and an equivalent DTX dose given systemically. At 40 days, 89% survival was observed for mice treated with DTX implants compared with 0% in all other treatment groups. The combined treatment with local DTX spacer and radiation (10Gy) showed the highest degree of tumor suppression (significant tumor growth inhibition by day 90). The control mice showed continuous tumor growth and were scarified by day 56. Groups of mice treated with DTX-spacer or radiation alone showed initial tumor suppression but growth continued after day 60. A larger experiment is ongoing. Conclusion: This approach provides localized delivery of the chemotherapeutic sensitizer directly to the tumor and avoids the toxicities associated with both brachytherapy and current systemic delivery of docetaxel. Sustained release of DTX is an effective chemotherapy option alone or in combination with radiation therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tiberi, David A.; Carrier, Jean-Francois; Beauchemin, Marie-Claude
2012-09-01
Purpose: To determine the extent of gold fiducial marker (FM) migration in patients treated for prostate cancer with concurrent androgen deprivation and external-beam radiation therapy (EBRT). Methods and Materials: Three or 4 gold FMs were implanted in 37 patients with prostate adenocarcinoma receiving androgen deprivation therapy (ADT) in conjunction with 70-78 Gy. Androgen deprivation therapy was started a median of 3.9 months before EBRT (range, 0.3-12.5 months). To establish the extent of FM migration, the distance between each FM was calculated for 5-8 treatments once per week throughout the EBRT course. For each treatment, the distance between FMs was comparedmore » with the distance from the digitally reconstructed radiographs generated from the planning CT. A total of 281 treatments were analyzed. Results: The average daily migration was 0.8 {+-} 0.3 mm, with distances ranging from 0.2 mm-2.6 mm. Two of the 281 assessed treatments (0.7%) showed migrations >2 mm. No correlation between FM migration and patient weight or time delay between ADT and start of EBRT was found. There was no correlation between the extent of FM migration and prostate volume. Conclusion: This is the largest report of implanted FM migration in patients receiving concomitant ADT. Only 0.7% of the 281 treatments studied had significant marker migrations (>2 mm) throughout the course of EBRT. Consequently, the use of implanted FMs in these patients enables accurate monitoring of prostate gland position during treatment.« less
Non-invasive imaging of prostate cancer progression in nude mice using iRFP gene reporter
NASA Astrophysics Data System (ADS)
Zhu, Banghe; Wu, Grace; Robinson, Holly; Wilganowski, Nathaniel; Sevick-Muraca, Eva M.
2013-03-01
Prostate cancer (PCa) is the second most common cancer in US men. Metastasis is the final step of tumor progression and remains the primary cause of PCa death. Hence preclinical, orthotopic models of PCa metastasis are necessary to develop new therapeutics against metastatic disease. Yet unlike irrelevant subcutaneous tumor models, the deployment of orthotopic models of cancer metastasis in drug research and development is limited by the inability to longitudinally monitor cancer progression/regression in response to administration of experimental pharmaceuticals. Recently, a nearinfrared fluorescent protein (iRFP) was created for deeper imaging [1]. Imaging prostate tumor growth and lymph node metastasis in nude mice therefore becomes possible using this new fluorescent gene reporter. In this study, we first developed an intensified CCD (ICCD)-based iRFP fluorescence imaging device. Then human PCa PC3 cell lines expressing iRFP gene reporter were orthotopically implanted in male Nu/Nu mice at 8-10 weeks old. After 6-10 weeks, in vivo, in situ and ex vivo fluorescence imaging was performed. In vivo iRFP fluorescence imaging showed that the detected fluorescence concentrated at the prostate and became stronger over time, indicating the growth of implanted PCa. Fluorescence was non-invasively detected at locations of prostate-draining lymph nodes as early as 5 weeks post implantation, indicating the metastasis to lymph nodes. In situ and ex vivo fluorescence imaging demonstrated that the detected signals from PCa and lymph nodes were correlated with cancer positive status of tissues as assessed through standard pathology.
Prostate cancer patients who have failed standard radiation therapy have the options of surgery, radioactive seed implantation or cryoablation. Deborah Citrin, M.D., of the Radiation Oncology Branch is leading a study of stereotactic body radiation therapy (SBRT) to treat prostate cancer that has recurred locally after standard radiation therapy. The goal of this study is to use a novel imaging approach to guide treatment and to define the best dose of SBRT for patients whose prostate cancer has recurred after standard radiotherapy. Read more...
Intra-operative Iodine-125 prostatic implant following bilateral pelvic lymphadenectomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwong, E.W.H.; Huh, S.H.; Nobler, M.P.
Sixty-five patients with prostatic adenocarcinoma Stages B and C were treated with intraoperative Iodine-125 prostatic implantation following bilateral pelvic lymphadenectomy. Pelvic nodal metastases were found in 31% of the patients. All the patients have been followed for a period of 1 1/2 to 6 years. Serial digital rectal examination revealed complete regression of the palpable disease in 15% of the patients at 6 months, 47% at 1 year, and 87% at 2 years. Post-operative complications were also evaluated: 13% of the patients became sexually impotent, 11% had impaired potency after the procedure, and 26% of patients complained of dry ejaculation;more » and 17% developed scrotal and/or penile swelling, which persisted up to 14 months, but usually subsided within 5 months. Two patients developed local recurrence.« less
Chira, Ciprian; Delouya, Guila; Larrivée, Sandra; Carrier, Jean-Francois; Taussky, Daniel
2013-07-09
To determine prostate volume (Pvol) changes at 3 different time points during the course of I¹²⁵ permanent seed brachytherapy (PB). To assess the impact of these changes on acute urinary retention (AUR) and dosimetric outcome. We analyzed 149 hormone-naïve patients. Measurements of the prostate volume were done using three-dimensional transrectal ultrasound (3D-TRUS) in the operating room before insertion of any needle (V1), after the insertion of 2 fixation needles with a harpoon (V2) and upon completion of the implant (V3). The quality of the implant was analyzed with the D90 (minimum dose in Grays received by 90% of the prostate volume) at day 30. Mean baseline prostate volume (V1) was 37.4 ± 9.6 cc. A volume increase of >5% was seen in 51% between V1-V2 (mean = 2.5 cc, p < 0.01), in 42% between V2-V3 (mean = 1.9 cc, p < 0.01) and in 71% between V1-V3 (mean = 4.5 cc, p < 0.01). Pvol changes caused by insertion of the fixation needles were not statistically different than those caused by the implant itself (p = 0.23).In multivariate linear regression analysis, baseline Pvol is predictive of Pvol changes between V2 and V1 and V3 and V1 but not between V3 and V2. The extent of prostate swelling had an influence on D90. An increase of 10% in prostate volume between V1 and V2 results in an increase of D90 at Day 30 by 11.7%. Baseline Pvol (V1) was the only predictor of the duration of urinary retention in both univariate and multivariate (p = 0.04) regression analysis. A large part of intraoperative swelling occurs already after the insertion of the fixation needles. This early prostate swelling predicts for D90 but not for AUR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ispir, B; Akdeniz, Y; Ugurluer, G
2015-06-15
Purpose: To evaluate prostate volume changes during radiation therapy using implanted gold markers and on-board imaging. Methods: Twenty-five patients were included who underwent an implantation of three gold markers. Cartesian coordinates of markers were assessed in kV-images. The coordinates of centers of two markers were measured on kV-images from the center of the marker at the apex which was reference. The distances between the markers were extrapolated from the coordinates using the Euclid formula. The radius of the sphere through markers was calculated using sinus theorem. The prostate volume for the first and last fraction was substituted with a spheremore » model and was calculated for each patient. The t-test was used for analysis. Results: The mean prostate volume for first and last fraction was 24.65 and 20.87 cc, respectively (p≤0.05). The prostate volume was smaller for 23 patients, whereas there was an expansion for 2 patients. Fifteen patients had androgen deprivation during radiotherapy (H group) and ten did not (NH group). The mean prostate volume for the first and last fraction for the NH group was 30.73 cc and 24.89 cc and for the H group 20.84 cc and 18.19 cc, respectively. There was a 15.8% volume change during treatment for the NH group and 12.2% for the H group, but the difference was not statistically significant. The radius difference of the theoretical sphere for the first and last fraction was 0.98 mm (range, 0.09–2.95 mm) and remained below 2 mm in 88% of measurements. Conclusion: There was a significant volume change during prostate radiotherapy. The difference between H group and NH group was not significant. The radius changes did not exceed 3 mm and it was below adaptive treatment requirements. Our results indicate that prostate volume changes during treatment should be taken into account during contouring and treatment planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Y; Saleh, Z; Tang, X
Purpose: Segmentation of prostate CBCT images is an essential step towards real-time adaptive radiotherapy. It is challenging For Calypso patients, as more artifacts are generated by the beacon transponders. We herein propose a novel wavelet-based segmentation algorithm for rectum, bladder, and prostate of CBCT images with implanted Calypso transponders. Methods: Five hypofractionated prostate patients with daily CBCT were studied. Each patient had 3 Calypso transponder beacons implanted, and the patients were setup and treated with Calypso tracking system. Two sets of CBCT images from each patient were studied. The structures (i.e. rectum, bladder, and prostate) were contoured by a trainedmore » expert, and these served as ground truth. For a given CBCT, the moving window-based Double Haar transformation is applied first to obtain the wavelet coefficients. Based on a user defined point in the object of interest, a cluster algorithm based adaptive thresholding is applied to the low frequency components of the wavelet coefficients, and a Lee filter theory based adaptive thresholding is applied to the high frequency components. For the next step, the wavelet reconstruction is applied to the thresholded wavelet coefficients. A binary/segmented image of the object of interest is therefore obtained. DICE, sensitivity, inclusiveness and ΔV were used to evaluate the segmentation result. Results: Considering all patients, the bladder has the DICE, sensitivity, inclusiveness, and ΔV ranges of [0.81–0.95], [0.76–0.99], [0.83–0.94], [0.02–0.21]. For prostate, the ranges are [0.77–0.93], [0.84–0.97], [0.68–0.92], [0.1–0.46]. For rectum, the ranges are [0.72–0.93], [0.57–0.99], [0.73–0.98], [0.03–0.42]. Conclusion: The proposed algorithm appeared effective segmenting prostate CBCT images with the present of the Calypso artifacts. However, it is not robust in two scenarios: 1) rectum with significant amount of gas; 2) prostate with very low contrast. Model based algorithm might improve the segmentation in these two scenarios.« less
Quality assurance of HDR prostate plans: program implementation at a community hospital.
Rush, Jennifer B; Thomas, Michael D
2005-01-01
Adenocarcinoma of the prostate is currently the most commonly diagnosed cancer in men in the United States, and the second leading cause of cancer mortality. The utilization of radiation therapy is regarded as the definitive local therapy of choice for intermediate- and high-risk disease, in which there is increased risk for extracapsular extension, seminal vesicle invasion, or regional node involvement. High-dose-rate (HDR) brachytherapy is a logical treatment modality to deliver the boost dose to an external beam radiation therapy (EBRT) treatment to increase local control rates. From a treatment perspective, the utilization of a complicated treatment delivery system, the compressed time frame in which the procedure is performed, and the small number of large dose fractions make the implementation of a comprehensive quality assurance (QA) program imperative. One aspect of this program is the QA of the HDR treatment plan. Review of regulatory and medical physics professional publications shows that substantial general guidance is available. We provide some insight to the implementation of an HDR prostate plan program at a community hospital. One aspect addressed is the utilization of the low-dose-rate (LDR) planning system and the use of existing ultrasound image sets to familiarize the radiation therapy team with respect to acceptable HDR implant geometries. Additionally, the use of the LDR treatment planning system provided a means to prospectively determine the relationship between the treated isodose volume and the product of activity and time for the department's planning protocol prior to the first HDR implant. For the first 12 HDR prostate implants, the root-mean-square (RMS) deviation was 3.05% between the predicted product of activity and time vs. the actual plan values. Retrospective re-evaluation of the actual implant data reduced the RMS deviation to 2.36%.
Ozten, Nur; Horton, Lori; Lasano, Salamia; Bosland, Maarten C
2010-03-01
Previous studies with selenium and/or vitamin E in prostate carcinogenesis animal models have been negative, but these models may not involve oxidative stress mechanisms. In this study, we examined the potential of selenomethionine and alpha-tocopherol to modulate prostate cancer development in the testosterone plus estradiol-treated NBL rat, a model that does involve sex hormone-induced oxidative stress mechanisms and prostatic inflammation. One week following the implantation with hormone-filled Silastic implants, rats were fed diets containing l-selenomethionine (1.5 or 3.0 mg/kg), DL-alpha-tocopherol acetate (2,000 or 4,000 mg/kg), or a natural ingredient control diet (NIH-07). The development of prostate carcinomas was not affected by dietary treatment with either agent. Food intake, body weight, and mortality were also not affected. The high dose of selenomethionine reduced the severity of epithelial dysplasia in the lateral prostate that was not associated with inflammation, and alpha-tocopherol reduced in a dose-related fashion the incidence of marked inflammation and marked epithelial dysplasia in the lateral prostate, regardless of whether these lesions were associated with inflammation. alpha-Tocopherol significantly increased the incidence of adenocarcinomas of the mammary glands at both dietary concentrations. Collectively, our findings suggest that selenomethionine and alpha-tocopherol supplementation does not prevent prostate cancer in rats fed diets with nutritionally adequate levels of selenium and vitamin E. Importantly, the results of the current animal studies and those reported previously were fully predictive of the outcome of the Selenium and Vitamin E Cancer Prevention Trial.
Özten, Nur; Horton, Lori; Lasano, Salamia; Bosland, Maarten C.
2009-01-01
Previous studies with selenium and/or vitamin E in prostate carcinogenesis animal models have been negative, but these models may not involve oxidative stress mechanisms. In this study, we examined the potential of selenomethionine and α-tocopherol to modulate prostate cancer development in the testosterone plus estradiol-treated NBL rat, a model that does involve sex-hormone induced oxidative stress mechanisms and prostatic inflammation. One week following implantation with hormone-filled Silastic implants, rats were fed diets containing L-selenomethionine (1. 5 or 3. 0 mg/kg), DL-α-tocopherol acetate (2,000 mg/kg or 4,000 mg/kg), or a natural ingredient control diet (NIH-07). Development of prostate carcinomas was not affected by dietary treatment with either agent. Food intake, body weight, and mortality were also not affected. The high dose of selenomethionine reduced the severity of epithelial dysplasia in the lateral prostate that was not associated with inflammation and α-tocopherol reduced in a dose-related fashion the incidence of marked inflammation and marked epithelial dysplasia in the lateral prostate, regardless of whether these lesions were associated with inflammation. α-Tocopherol significantly increased the incidence of adenocarcinomas of the mammary glands at both dietary concentrations. Collectively, our findings suggest that selenomethionine and α-tocopherol supplementation does not prevent prostate cancer in rats fed diets with nutritionally adequate levels of selenium and vitamin E. Importantly, the results of the current animal studies and those reported previously were fully predictive of the outcome of the SELECT trial. PMID:20179302
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, Andrew, E-mail: aojones@geisinger.edu; Treas, Jared; Yavoich, Brian
2014-01-01
The aim of the study was to investigate the differences between intraoperative and postoperative dosimetry for transrectal ultrasound–guided transperineal prostate implants using cesium-131 ({sup 131}Cs). Between 2006 and 2010, 166 patients implanted with {sup 131}Cs had both intraoperative and postoperative dosimetry studies. All cases were monotherapy and doses of 115 were prescribed to the prostate. The dosimetric properties (D{sub 90}, V{sub 150}, and V{sub 100} for the prostate) of the studies were compared. Two conformity indices were also calculated and compared. Finally, the prostate was automatically sectioned into 6 sectors (anterior and posterior sectors at the base, midgland, and apex)more » and the intraoperative and postoperative dosimetry was compared in each individual sector. Postoperative dosimetry showed statistically significant changes (p < 0.01) in every dosimetric value except V{sub 150}. In each significant case, the postoperative plans showed lower dose coverage. The conformity indexes also showed a bimodal frequency distribution with the index indicating poorer dose conformity in the postoperative plans. Sector analysis revealed less dose coverage postoperatively in the base and apex sectors with an increase in dose to the posterior midgland sector. Postoperative dosimetry overall and in specific sectors of the prostate differs significantly from intraoperative planning. Care must be taken during the intraoperative planning stage to ensure complete dose coverage of the prostate with the understanding that the final postoperative dosimetry will show less dose coverage.« less
Lee, Jin Young; Sung, Kyung Rim; Tchah, Hung Won; Yoon, Young Hee; Kim, June Gone; Kim, Myoung Joon; Kim, Jae Yong; Yun, Sung-Cheol; Lee, Joo Yong
2012-12-01
To evaluate whether a combination of penetrating keratoplasty (PKP) or pars plana vitrectomy (PPV) and Ahmed glaucoma valve (AGV) implantation affords a level of success similar to that of AGV implantation alone. Eighteen eyes underwent simultaneous PPV and AGV, 14 eyes with PKP and AGV and 30 eyes with AGV implantation alone were evaluated. Success was defined as attainment of an intraocular pressure (IOP) >5 and <22 mmHg, with or without use of anti-glaucoma medication. Kaplan-Meier survival analysis was performed to compare cumulative survival between the combined surgery groups and the AGV implantation-alone group. Cox proportional hazard regression analysis was conducted to identify factors predictive of success in each of the three groups. Mean (±standard deviation) preoperative IOP was 30.2 ± 10.2 mmHg in the PKP + AGV, 35.2 ± 9.8 mmHg in the PPV + AGV, and 36.2 ± 10.1 mmHg in the AGV implantation-alone group. The cumulative success rate at 18 months was 66.9%, 73.2%, and 70.8% in the three groups, respectively. Neither combined surgery group differed significantly in terms of cumulative success rate compared with the AGV implantation-alone group (p = 0.556, p = 0.487, respectively). The mean number of preoperative anti-glaucoma medications prescribed was significantly associated with success in the PKP + AGV implantation group (hazard ratio, 2.942; p = 0.024). Either PKP or PPV performed in conjunction with AGV implantation afforded similar success rates compared to patients treated with AGV implantation alone. Therefore, in patients with refractory glaucoma who have underlying corneal or retinal pathology requiring treatment with PKP or PPV, AGV implantation can be performed simultaneously.
Par-4-mediated recruitment of Amida to the actin cytoskeleton leads to the induction of apoptosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boosen, Meike; Vetterkind, Susanne; Koplin, Ansgar
Par-4 (prostate apoptosis response-4) sensitizes cells to apoptotic stimuli, but the exact mechanisms are still poorly understood. Using Par-4 as bait in a yeast two-hybrid screen, we identified Amida as a novel interaction partner, a ubiquitously expressed protein which has been suggested to be involved in apoptotic processes. Complex formation of Par-4 and Amida occurs in vitro and in vivo and is mediated via the C-termini of both proteins, involving the leucine zipper of Par-4. Amida resides mainly in the nucleus but displays nucleo-cytoplasmic shuttling in heterokaryons. Upon coexpression with Par-4 in REF52.2 cells, Amida translocates to the cytoplasm andmore » is recruited to actin filaments by Par-4, resulting in enhanced induction of apoptosis. The synergistic effect of Amida/Par-4 complexes on the induction of apoptosis is abrogated when either Amida/Par-4 complex formation or association of these complexes with the actin cytoskeleton is impaired, indicating that the Par-4-mediated relocation of Amida to the actin cytoskeleton is crucial for the pro-apoptotic function of Par-4/Amida complexes in REF52.2 cells. The latter results in enhanced phosphorylation of the regulatory light chain of myosin II (MLC) as has previously been shown for Par-4-mediated recruitment of DAP-like kinase (Dlk), suggesting that the recruitment of nuclear proteins involved in the regulation of apoptotic processes to the actin filament system by Par-4 represents a potent mechanism how Par-4 can trigger apoptosis.« less
Lichius, J J; Muth, C
1997-08-01
Extracts of stinging nettle roots (Urtica dioica L. Urticaceae) are used in the treatment of benign prostatic hyperplasia (BPH). We established a BPH-model by directly implanting an urogenital sinus (UGS) into the ventral prostate gland of an adult mouse. Five differently prepared stinging nettle root extracts were tested in this model. The 20% methanolic extract was the most effective with a 51.4% inhibition of induced growth.
Minimally invasive ultrasound thermal therapy with MR thermal monitoring and guidance
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Stafford, R. Jason; Price, Roger E.; Nau, William H.; Tyreus, Per Daniel; Rivera, Belinda; Schomer, Donald; Olsson, Lars; Hazle, John D.
2001-06-01
In this study both transurethral and interstitial ultrasound thermal therapy were applied to thermally coagulate targeted portions of the canine prostate or brain and implanted TVT tumors while using MRI-based thermal mapping techniques to monitor the therapy. MRI was also used for target definition, positioning of the applicator, and evaluation of target viability post-therapy. The complex phase-difference mapping technique using an iGE-EPI sequence with lipid suppression was used for determining temperature elevations within the in vivo prostate or brain and surrounding structures. Calculated temperature distributions, thermal dose exposures, T2-wieghted & T1-contrast enhanced images, gross inspection, and histology of sectioned prostates and brains were in good agreement with each other in defining destroyed tissue zones. Interstitial and transurethral ultrasound applicators produce directed zones of thermal coagulation within targeted tissue and implanted tumor, which can be accurately monitored and evaluated by MRI.
Automated seed localization from CT datasets of the prostate.
Brinkmann, D H; Kline, R W
1998-09-01
With the increasing utilization of permanent brachytherapy implants for treating carcinoma of the prostate, the importance of accurate post-treatment dose calculation also increases for assessing patient outcome and planning future treatments. An automatic method for seed localization of permanent brachytherapy implants, using CT datasets of the prostate, has been developed and tested on a phantom using an actual patient planned seed distribution. This method was also compared to results with the three-film technique for three patient datasets. The automatic method is as accurate or more accurate than the three film technique for 1 mm, 3 mm, and 5 mm contiguous CT slices, and eliminates the inter- and intra-observer variability of the manual methods. The automated method improves the localization of brachytherapy seeds while reducing the time required for the user to input information, and is demonstrated to be less operator dependent, less time consuming, and potentially more accurate than the three-film technique.
Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K.; Goncalves, Alexandra; Di Carli, Marcelo F.; Rybicki, Frank J.; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron
2017-01-01
Background 3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. Objective To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). Methods This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Results Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of −0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Conclusions Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. PMID:26732862
Meyer, Tyler; Sia, Michael; Angyalfi, Steve; Husain, Siraj
2017-01-01
Purpose To develop a model for prostate specific antigen (PSA) values at one year among patients treated with intraoperatively planned 125I prostate brachytherapy (IOPB). Material and methods Four hundred and deven patients treated with IOPB for prostate adenocarcinoma were divided into four groups: those with PSA values ≥ 3 ng/ml; < 3 and ≥ 2; < 2 and ≥ 1 or PSA < 1 between 10.5 and 14.5 months post implantation (1yPSA). Ordinal regression analysis was then performed between patient, tumor, and treatment characteristics. 1yPSA values were also compared with toxicity outcomes. Results Median 1yPSA was 0.77 (0.04-17.36). Thirty-two patients (8%) had a PSA ≥ 3; 35 (9%) had PSA < 3, ≥ 2; 87 (21%) had PSA < 2, ≥ 1, and most patients 254 (62%) had PSA < 1. PSA response was independent of gland volume, Gleason score, clinical stage, seed activity, V90, V200, D90, or number of needles and seeds used. Older patients had significantly lower 1yPSA; median ages 65.1 (46.5-81.0), 62.1 (50.4-79.5), 60.5 (47.1-80.3), and 58.1 (45.1-74.2) years for each of the 1yPSA groups respectively (p < 0.001). Also, both implant V150 (p < 0.001) and initial PSA values (p = 0.04) were predictive of 1yPSA values. There was no correlation between 1yPSA values and toxicity encountered. Conclusions PSA response at 1 year post IOPB appears to be dependent on patient age, initial PSA, and implant V150. Our results provide reassurance that parameters other than biochemical failure influence 1yPSA values. PMID:28533796
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davies, Rhian Siân, E-mail: rhian.s.davies@wales.nhs.uk; Perrett, Teresa; Powell, Jane
A study was performed to establish whether transrectal ultrasound (TRUS)-based postimplant dosimetry (PID) is both practically feasible and comparable to computed tomography (CT)-based PID, recommended in current published guidelines. In total, 22 patients treated consecutively at a single cancer center with low-dose-rate (LDR) brachytherapy for early-stage prostate cancer had a transrectal ultrasound performed immediately after implant (d0-TRUS) and computed tomography scan 30 days after implant (d30-CT). Postimplant dosimetry planning was performed on both image sets and the results were compared. The interobserver reproducibility of the transrectal ultrasound postimplant dosimetry planning technique was also assessed. It was noticed that there wasmore » no significant difference in mean prostate D{sub 90} (136.5 Gy and 144.4 Gy, p = 0.2197), V{sub 100} (86.4% and 89.1%, p = 0.1480) and V{sub 150} (52.0% and 47.8%, p = 0.1657) for d30-CT and d0-TRUS, respectively. Rectal doses were significantly higher for d0-TRUS than d30-CT. Urethral doses were available with d0-TRUS only. We have shown that d0-TRUS PID is a useful tool for assessing the quality of an implant after low-dose-rate prostate brachytherapy and is comparable to d30-CT PID. There are clear advantages to its use in terms of resource and time efficiency both for the clinical team and the patient.« less
SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Y; Tward, J; Rassiah-Szegedi, P
Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seedmore » counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients where preplan TRUS may be technically challenging.« less
2012-09-01
for the treatment of prostate tumor-bearing mice using a clinical MRgHIFU device. We performed animal studies for quantitative measurement of the...by measuring the protein expression level of MDM2, p53 and p21 using immunohistochemical staining and west blotting techniques. We also performed...therapy) in implanted prostate tumors in mice in vivo by measuring the protein expression level of MDM, p53 and p21 with time points after treatment
Sarkar, V; Gutierrez, A N; Stathakis, S; Swanson, G P; Papanikolaou, N
2009-01-01
The purpose of this project was to develop a software platform to produce a virtual fluoroscopic image as an aid for permanent prostate seed implants. Seed location information from a pre-plan was extracted and used as input to in-house developed software to produce a virtual fluoroscopic image. In order to account for differences in patient positioning on the day of treatment, the user was given the ability to make changes to the virtual image. The system has been shown to work as expected for all test cases. The system allows for quick (on average less than 10 sec) generation of a virtual fluoroscopic image of the planned seed pattern. The image can be used as a verification tool to aid the physician in evaluating how close the implant is to the planned distribution throughout the procedure and enable remedial action should a large deviation be observed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warrell, G; Shvydka, D; Chen, C
Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains onemore » of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.« less
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.
2011-03-01
A clinical treatment delivery platform has been developed and is being evaluated in a clinical pilot study for providing 3D controlled hyperthermia with catheter-based ultrasound applicators in conjunction with high dose rate (HDR) brachytherapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within HDR brachytherapy implants during radiation therapy in the treatment of cervix and prostate. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length × 180 deg and 3-4 cm × 360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers × dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and six prostate implants. 100 % of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target volume (HTV) and clinical target volume (CTV) are reported. Catheter-based ultrasound hyperthermia with HDR appears feasible with therapeutic temperature coverage of the target volume within the prostate or cervix while sparing surrounding more sensitive regions.
Bosland, M C; Ford, H; Horton, L
1995-06-01
This study determined the incidence of prostate adenocarcinoma following long-term treatment of NBL and Sprague-Dawley rats with estradiol-17 beta or diethylstilbestrol (DES) plus testosterone and it defined the origin of these tumors. NBL and Sprague-Dawley rats were treated with two Silastic tubing implants (i.d. 1.6 mm, o.d. 3.2 mm) containing a 2 cm long filling of testosterone and one implant containing a 1 cm long filling of estradiol-17 beta or DES. Control animals received empty implants. Treated animals were killed when moribund and controls were killed at 91 (NBL) or 75 (Sprague-Dawley) weeks after initiation of treatment and accessory sex glands were sampled for histopathological examination of multiple step sections. Prostatic adenocarcinoma occurred in 100% of NBL rats after treatment with estradiol-17 beta or DES plus testosterone for 44 and 59 weeks (group means) respectively. Adenocarcinoma incidences were lower in Sprague-Dawley rats. The adenocarcinomas were small, microscopic, invasive tumors and they were spatially closely associated with the periurethral ducts of the dorsal, lateral and/or anterior (= coagulating gland) prostate, but never with the ducts of the ventral lobe and seminal vesicles. One adenocarcinoma was of uncertain origin. Duct-acinar dysplastic lesions occurred in the periphery of the dorsal and lateral prostate of all hormone-treated NBL and many Sprague-Dawley rats, but did not appear to give rise to carcinoma. Although some adenocarcinomas were contiguous with dysplastic ducts of the peripheral dorsolateral prostate, the main mass of these neoplasms was located in the periurethral area. Also, most adenocarcinomas were only connected with the periurethral ducts, in which atypical hyperplasia occurred following hormone treatment for 36 weeks or longer. Thus atypical hyperplasia of the periurethral prostate ducts, but not peripheral duct-acinar dysplasia, appeared to be the likely precursor of the induced carcinomas. Testosterone plus DES, but not estradiol-17 beta, induced marked dysplasia-like lesions in the acini of the ventral prostate of all NBL and many Sprague-Dawley rats. These lesions had progressed to carcinoma in situ (or adenoma) in 46% of NBL rats.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Babier, A; Joshi, C; Cancer Center of Southeastern Ontario, Kingston General Hospital, Kingston, Ontario
Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations weremore » validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan optimality than prostate volume changes.« less
Deformable registration of x-ray to MRI for post-implant dosimetry in prostate brachytherapy
NASA Astrophysics Data System (ADS)
Park, Seyoun; Song, Danny Y.; Lee, Junghoon
2016-03-01
Post-implant dosimetric assessment in prostate brachytherapy is typically performed using CT as the standard imaging modality. However, poor soft tissue contrast in CT causes significant variability in target contouring, resulting in incorrect dose calculations for organs of interest. CT-MR fusion-based approach has been advocated taking advantage of the complementary capabilities of CT (seed identification) and MRI (soft tissue visibility), and has proved to provide more accurate dosimetry calculations. However, seed segmentation in CT requires manual review, and the accuracy is limited by the reconstructed voxel resolution. In addition, CT deposits considerable amount of radiation to the patient. In this paper, we propose an X-ray and MRI based post-implant dosimetry approach. Implanted seeds are localized using three X-ray images by solving a combinatorial optimization problem, and the identified seeds are registered to MR images by an intensity-based points-to-volume registration. We pre-process the MR images using geometric and Gaussian filtering. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine transformation and local deformable registration. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. We tested our algorithm on six patient data sets, achieving registration error of (1.2+/-0.8) mm in < 30 sec. Our proposed approach has the potential to be a fast and cost-effective solution for post-implant dosimetry with equivalent accuracy as the CT-MR fusion-based approach.
Singh, Shalini; Pan, Chunliu; Wood, Ronald; Yeh, Chiuan-Ren; Yeh, Shuyuan; Sha, Kai; Krolewski, John J; Nastiuk, Kent L
2015-09-21
Genetically engineered mouse models are essential to the investigation of the molecular mechanisms underlying human prostate pathology and the effects of therapy on the diseased prostate. Serial in vivo volumetric imaging expands the scope and accuracy of experimental investigations of models of normal prostate physiology, benign prostatic hyperplasia and prostate cancer, which are otherwise limited by the anatomy of the mouse prostate. Moreover, accurate imaging of hyperplastic and tumorigenic prostates is now recognized as essential to rigorous pre-clinical trials of new therapies. Bioluminescent imaging has been widely used to determine prostate tumor size, but is semi-quantitative at best. Magnetic resonance imaging can determine prostate volume very accurately, but is expensive and has low throughput. We therefore sought to develop and implement a high throughput, low cost, and accurate serial imaging protocol for the mouse prostate. We developed a high frequency ultrasound imaging technique employing 3D reconstruction that allows rapid and precise assessment of mouse prostate volume. Wild-type mouse prostates were examined (n = 4) for reproducible baseline imaging, and treatment effects on volume were compared, and blinded data analyzed for intra- and inter-operator assessments of reproducibility by correlation and for Bland-Altman analysis. Examples of benign prostatic hyperplasia mouse model prostate (n = 2) and mouse prostate implantation of orthotopic human prostate cancer tumor and its growth (n = ) are also demonstrated. Serial measurement volume of the mouse prostate revealed that high frequency ultrasound was very precise. Following endocrine manipulation, regression and regrowth of the prostate could be monitored with very low intra- and interobserver variability. This technique was also valuable to monitor the development of prostate growth in a model of benign prostatic hyperplasia. Additionally, we demonstrate accurate ultrasound image-guided implantation of orthotopic tumor xenografts and monitoring of subsequent tumor growth from ~10 to ~750 mm(3) volume. High frequency ultrasound imaging allows precise determination of normal, neoplastic and hyperplastic mouse prostate. Low cost and small image size allows incorporation of this imaging modality inside clean animal facilities, and thereby imaging of immunocompromised models. 3D reconstruction for volume determination is easily mastered, and both small and large relative changes in volume are accurately visualized. Ultrasound imaging does not rely on penetration of exogenous imaging agents, and so may therefore better measure poorly vascularized or necrotic diseased tissue, relative to bioluminescent imaging (IVIS). Our method is precise and reproducible with very low inter- and intra-observer variability. Because it is non-invasive, mouse models of prostatic disease states can be imaged serially, reducing inter-animal variability, and enhancing the power to detect small volume changes following therapeutic intervention.
WE-AB-BRA-12: Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S; Song, D; Lee, J
Purpose: For post-implant dosimetric assessment after prostate brachytherapy, CT-MR fusion approach has been advocated due to the superior accuracy on both seeds localization and soft tissue delineation. However, CT deposits additional radiation to the patient, and seed identification in CT requires manual review and correction. In this study, we propose an accurate, low-dose, and cost-effective post-implant dosimetry approach based on X-ray and MRI. Methods: Implanted seeds are reconstructed using only three X-ray fluoroscopy images by solving a combinatorial optimization problem. The reconstructed seeds are then registered to MR images using an intensity-based points-to-volume registration. MR images are first pre-processed bymore » geometric and Gaussian filtering, yielding smooth candidate seed-only images. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine followed by local deformable registrations. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. Results: We tested our algorithm on twenty patient data sets. For quantitative evaluation, we obtained ground truth seed positions by fusing the post-implant CT-MR images. Seeds were semi-automatically extracted from CT and manually corrected and then registered to the MR images. Target registration error (TRE) was computed by measuring the Euclidean distances from the ground truth to the closest registered X-ray seeds. The overall TREs (mean±standard deviation in mm) are 1.6±1.1 (affine) and 1.3±0.8 (affine+deformable). The overall computation takes less than 1 minute. Conclusion: It has been reported that the CT-based seed localization error is ∼1.6mm and the seed localization uncertainty of 2mm results in less than 5% deviation of prostate D90. The average error of 1.3mm with our system outperforms the CT-based approach and is considered well within the clinically acceptable limit. Supported in part by NIH/NCI grant 5R01CA151395. The X-ray-based implant reconstruction method (US patent No. 8,233,686) was licensed to Acoustic MedSystems Inc.« less
Porpiglia, Francesco; Fiori, Cristian; Bertolo, Riccardo; Garrou, Diletta; Cattaneo, Giovanni; Amparore, Daniele
2015-08-01
To report the first clinical experience with a temporary implantable nitinol device (TIND; Medi-Tate(®) ) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). In all, 32 patients with LUTS were enrolled in this prospective study, which was approved by our Institutional Ethics Committee. Inclusion criteria were: age >50 years, International Prostate Symptom Score (IPSS) of ≥10, maximum urinary flow rate (Qmax ) of ≤12 mL/s, and prostate volume of <60 mL. The TIND was implanted within the bladder neck and the prostatic urethra under light sedation, using a rigid cystoscope. The device was removed 5 days later in an outpatient setting. Demographics, perioperative results, complications (according to the Clavien system), functional results and quality of life (QoL) were evaluated. Follow-up assessments were made at 3 and 6 weeks, and 3, 6 and 12 months postoperatively. The Student's t-test, analysis of variance (anova), Kruskall-Wallis test, and simple and multiple linear regression models were used in the statistical analyses. The mean patient age was 69.4 years, the mean (standard deviation, sd) prostate volume was 29.5 (7.4) mL and the Qmax was 7.6 (2.2) mL/s. The median (interquartile range, IQR) IPSS was 19 (14-23) and QoL score was 3 (3-4). All the implantations were successful, with no intraoperative complications recorded. The mean operative time (sd) was 5.8 (2.5) min and the median (IQR) postoperative stay was 1 (1-2) day. All but one of the devices (96%) was removed 5 days at after implantation in an outpatient setting. Four complications (12.5%) were recorded, including urinary retention (one, 3.1%), transient incontinence due to device displacement (one, 3.1%), prostatic abscess (one, 3.1%), and urinary tract infection (one, 3.1%). Multiple regression analysis failed to identify any independent prognostic factor for complications. There were statistically significant differences in the IPSS, QoL score and Qmax when comparing pre- and postoperative results at every time point. After 12 months, the median (IQR) IPSS and QoL score were 9 (7-13) and 1 (1-2), respectively, and the mean (sd) Qmax was 12 (4.7) mL/s. The mean variations with respect to baseline conditions at the same time points were -45% for the IPSS and +67% for Qmax . At 12 months after surgery (last follow-up visit), no patients required medical therapy or surgical procedures for BPH. TIND implantation is a feasible and safe minimally invasive option for the treatment of BPH-related LUTS. The functional results are encouraging and the treatment significantly improved patient QoL. Further studies are required to assess durability of TIND results and to optimise the indications of such a procedure. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.
Urinary morbidity following ultrasound-guided transperineal prostate seed implantation.
Gelblum, D Y; Potters, L; Ashley, R; Waldbaum, R; Wang, X H; Leibel, S
1999-08-01
To assess the urinary morbidity experienced by patients undergoing ultrasound-guided, permanent transperineal seed implantation for adenocarcinoma of the prostate. Between September 1992 and September 1997, 693 consecutive patients presented with a diagnosis of clinically localized adenocarcinoma of the prostate, and were treated with ultrasound-guided transperineal interstitial permanent brachytherapy (TPIPB). Ninety-three patients are excluded from this review, having received neoadjuvant antiandrogen therapy. TPIPB was performed with 125I in 165 patients and with 103Pd in 435 patients. Patients treated with implant alone received 160 Gy with 125I (pre TG43) or 120 Gy with 103Pd. One hundred two patients received preimplant, pelvic external beam radiation (XRT) to a dose of either 41.4 or 45 Gy because of high-risk features including PSA > or = 10 and/or Gleason score > or = 7. Combined modality patients received 120 Gy and 90 Gy, respectively for 125I or 103Pd. All patients underwent postimplant cystoscopy and placement of an indwelling Foley catheter for 24-48 h. Follow-up was at 5 weeks after implant, every 3 months for the first 2 years, and then every 6 months for subsequent years. Patients completed AUA urinary symptom scoring questionnaires at initial consultation and at each follow-up visit. Urinary toxicity was classified by the RTOG toxicity scale with the following adaptations; grade 1 urinary toxicity was symptomatic nocturia or frequency requiring none or minimal medical intervention such as phenazopyridine; grade 2 urinary toxicity was early obstructive symptomatology requiring alpha-blocker therapy; and grade 3 toxicity was considered that requiring indwelling catheters or posttreatment transurethral resection of the prostate for symptom relief. Log-rank analysis and Chi-square testing was performed to assess AUA score, prostate size, isotope selection, and the addition of XRT as possible prognosticators of postimplant urinary toxicity. The prostate volume receiving 150% of the prescribed dose (V150) was studied in patients to assess its correlation with urinary toxicity. Median follow-up was 37 months (range 6-68). Within the first 60 days, 37.3% of the patients reported grade 1 urinary toxicity, 41% had grade 2, and 2.2% had grade 3 urinary toxicity. By 6 months, 21.4% still reported grade 1 urinary toxicity, whereas 12.8% and 3% complained of grade 2 and 3 urinary difficulties, respectively. Patients with a preimplant AUA score < or = 7 had significantly less grade II toxicity at 60 days compared to those with an AUA score of >7 (32% vs. 59.2%, respectively, p = 0.001). Similarly, prostatic volumes < or = 35 cc had a significantly lower incidence of grade II urinary toxicity (p = 0.001). There was no difference in toxicity regarding the isotope used (p = 0.138 at 60 days, p = 0.45 at 6 months) or the addition of preimplant XRT (p = 0.069 at 60 days, p = 0.84 at 6 months). Twenty-eight patients (4.7%) underwent TURP after 3 isotope half-lives for protracted obstructive symptoms. Five of these men (17%) developed stress incontinence following TURP, but all patients experienced relief of their obstructive symptoms without morbidity at last follow-up. The percent of the prostate receiving 150% of the prescribed dose (V150) did not predict urinary toxicity. TPIPB is well tolerated but associated with mild to moderate urinary morbidity. Pretreatment prostatic volume and AUA scoring were shown to significantly predict for grade 2 toxicity while the use of preimplant, pelvic XRT and isotope selection did not. Patients undergoing TURP for protracted symptoms following TPIPB did well with a 17% risk of developing stress incontinence. V150 did not help identify patients at risk for urinary morbidity. As transperineal prostate implantation is used more frequently the associated toxicities and the definition of possible pretreatment prognostic factors is necessary to
Miksys, N; Xu, C; Beaulieu, L; Thomson, R M
2015-08-07
This work investigates and compares CT image metallic artifact reduction (MAR) methods and tissue assignment schemes (TAS) for the development of virtual patient models for permanent implant brachytherapy Monte Carlo (MC) dose calculations. Four MAR techniques are investigated to mitigate seed artifacts from post-implant CT images of a homogeneous phantom and eight prostate patients: a raw sinogram approach using the original CT scanner data and three methods (simple threshold replacement (STR), 3D median filter, and virtual sinogram) requiring only the reconstructed CT image. Virtual patient models are developed using six TAS ranging from the AAPM-ESTRO-ABG TG-186 basic approach of assigning uniform density tissues (resulting in a model not dependent on MAR) to more complex models assigning prostate, calcification, and mixtures of prostate and calcification using CT-derived densities. The EGSnrc user-code BrachyDose is employed to calculate dose distributions. All four MAR methods eliminate bright seed spot artifacts, and the image-based methods provide comparable mitigation of artifacts compared with the raw sinogram approach. However, each MAR technique has limitations: STR is unable to mitigate low CT number artifacts, the median filter blurs the image which challenges the preservation of tissue heterogeneities, and both sinogram approaches introduce new streaks. Large local dose differences are generally due to differences in voxel tissue-type rather than mass density. The largest differences in target dose metrics (D90, V100, V150), over 50% lower compared to the other models, are when uncorrected CT images are used with TAS that consider calcifications. Metrics found using models which include calcifications are generally a few percent lower than prostate-only models. Generally, metrics from any MAR method and any TAS which considers calcifications agree within 6%. Overall, the studied MAR methods and TAS show promise for further retrospective MC dose calculation studies for various permanent implant brachytherapy treatments.
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.
2011-09-01
Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within temporary HDR brachytherapy implants during radiation therapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length×180 deg and 3-4 cm×360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers x dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and four prostate implants. 100% of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target volume (HTV) and clinical target volume (CTV) are reported. Catheter-based ultrasound hyperthermia with HDR appears feasible with therapeutic temperature coverage of the target volume within the prostate or cervix while sparing surrounding more sensitive regions.
Brenner, David J; Martinez, Alvaro A; Edmundson, Gregory K; Mitchell, Christina; Thames, Howard D; Armour, Elwood P
2002-01-01
A direct approach to the question of whether prostate tumors have an atypically high sensitivity to fractionation (low alpha/beta ratio), more typical of the surrounding late-responding normal tissue. Earlier estimates of alpha/beta for prostate cancer have relied on comparing results from external beam radiotherapy (EBRT) and brachytherapy, an approach with significant pitfalls due to the many differences between the treatments. To circumvent this, we analyze recent data from a single EBRT + high-dose-rate (HDR) brachytherapy protocol, in which the brachytherapy was given in either 2 or 3 implants, and at various doses. For the analysis, standard models of tumor cure based on Poisson statistics were used in conjunction with the linear-quadratic formalism. Biochemical control at 3 years was the clinical endpoint. Patients were matched between the 3 HDR vs. 2 HDR implants by clinical stage, pretreatment prostate-specific antigen (PSA), Gleason score, length of follow-up, and age. The estimated value of alpha/beta from the current analysis of 1.2 Gy (95% CI: 0.03, 4.1 Gy) is consistent with previous estimates for prostate tumor control. This alpha/beta value is considerably less than typical values for tumors (> or =8 Gy), and more comparable to values in surrounding late-responding normal tissues. This analysis provides strong supporting evidence that alpha/beta values for prostate tumor control are atypically low, as indicated by previous analyses and radiobiological considerations. If true, hypofractionation or HDR regimens for prostate radiotherapy (with appropriate doses) should produce tumor control and late sequelae that are at least as good or even better than currently achieved, with the added possibility that early sequelae may be reduced.
Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K; Goncalves, Alexandra; Di Carli, Marcelo F; Rybicki, Frank J; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron
2016-01-01
3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Targeted Prostate Thermal Therapy with Catheter-Based Ultrasound Devices and MR Thermal Monitoring
NASA Astrophysics Data System (ADS)
Diederich, Chris; Ross, Anthony; Kinsey, Adam; Nau, Will H.; Rieke, Viola; Butts Pauly, Kim; Sommer, Graham
2006-05-01
Catheter-based ultrasound devices have significant advantages for thermal therapy procedures, including potential for precise spatial and dynamic control of heating patterns to conform to targeted volumes. Interstitial and transurethral ultrasound applicators, with associated treatment strategies, were developed for thermal ablation of prostate combined with MR thermal monitoring. Four types of multielement transurethral applicators were devised, each with different levels of selectivity and intended therapeutic goals: sectored tubular transducer devices with fixed directional heating patterns; planar and lightly focused curvilinear devices with narrow heating patterns; and multi-sectored tubular devices capable of dynamic angular control without applicator movement. These devices are integrated with a 4 mm delivery catheter, incorporate an inflatable cooling balloon (10 mm OD) for positioning within the prostate and capable of rotation via an MR-compatible motor. Similarly, interstitial devices (2.4 mm OD) have been developed for percutaneous implantation with fixed directional heating patterns (e.g., 180 deg.). In vivo experiments in canine prostate (n=15) under MR temperature imaging were used to evaluate the heating technology and develop treatment strategies. MR thermal imaging in a 0.5 T interventional MRI was used to monitor temperature contours and thermal dose in multiple slices through the target volume. Sectored transurethral devices produce directional coagulation zones, extending 15-20 mm radial distance to the outer prostate capsule. The curvilinear applicator produces distinct 2-3 mm wide lesions, and with sequential rotation and modulated dwell time can precisely conform thermal ablation to selected areas or the entire prostate gland. Multi-sectored transurethral applicators can dynamically control the angular heating profile and target large regions of the gland in short treatment times without applicator manipulation. Interstitial implants with directional devices can be used to effectively ablate the posterior peripheral zone of the gland while protecting the rectum. An implant with multi-sectored interstitial devices can effectively control the angular heating pattern without applicator rotation. The MR derived 52 °C and lethal thermal dose contours (t43=240 min) allowed for real-time control of the applicators and effectively defined the extent of thermal damage. Catheter-based ultrasound devices, combined with MR thermal monitoring, can produce relatively fast and precise thermal ablation of prostate, with potential for treatment of cancer or BPH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, Wayne M., E-mail: wbutler@wheelinghospital.org; Wheeling Jesuit University, Wheeling, West Virginia; Morris, Mallory N.
2012-10-01
Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in themore » study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.« less
Urethral toxicity after LDR brachytherapy: experience in Japan.
Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide
2015-01-01
Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Critz, Frank A
2002-03-01
Freedom from prostate cancer is defined by undetectable prostate specific antigen (PSA) after surgery and the American Society of Therapeutic Radiology and Oncology (ASTRO) criteria are recommended for irradiation. Whether these definitions of disease freedom are comparable was evaluated in this study. From August 1992 to August 1996 simultaneous irradiation with prostate 125iodine implantation followed by external beam irradiation was performed in 591 consecutive men with stage T1T2NX prostate cancer. All patients had a transperineal implant and none received neoadjuvant hormones. Disease freedom was defined by a PSA cutoff of 0.2 ng./ml. and the ASTRO consensus definition. Median followup was 6 years (range 5 to 8). Of the 591 men in this study 65 had recurrence by ASTRO criteria and 93 had recurrence by a PSA cutoff of 0.2 ng./ml., which was a significant difference (p = 0.001). On multivariate analysis of the factors related to disease-free status the definition of disease freedom, pretreatment PSA and Gleason score were highly significant. Of the 528 men with a minimum 5-year PSA followup the 8-year disease-free survival rate by ASTRO criteria was 99% in those who achieved a PSA nadir of 0.2 ng./ml. and 16% in those with a nadir of 0.3 to 1 ng./ml. Of the 469 disease-free patients by ASTRO criteria with a minimum 5-year followup 455 (97%) achieved a PSA nadir of 0.2 ng./ml. or less. The definition of freedom from prostate cancer significantly affects treatment results. A standard definition is needed and a PSA cutoff of 0.2 ng./ml. is suggested as the standard for all curative treatments for localized prostate cancer.
Prostate Brachytherapy Seed Reconstruction with Gaussian Blurring and Optimal Coverage Cost
Lee, Junghoon; Liu, Xiaofeng; Jain, Ameet K.; Song, Danny Y.; Burdette, E. Clif; Prince, Jerry L.; Fichtinger, Gabor
2009-01-01
Intraoperative dosimetry in prostate brachytherapy requires localization of the implanted radioactive seeds. A tomosynthesis-based seed reconstruction method is proposed. A three-dimensional volume is reconstructed from Gaussian-blurred projection images and candidate seed locations are computed from the reconstructed volume. A false positive seed removal process, formulated as an optimal coverage problem, iteratively removes “ghost” seeds that are created by tomosynthesis reconstruction. In an effort to minimize pose errors that are common in conventional C-arms, initial pose parameter estimates are iteratively corrected by using the detected candidate seeds as fiducials, which automatically “focuses” the collected images and improves successive reconstructed volumes. Simulation results imply that the implanted seed locations can be estimated with a detection rate of ≥ 97.9% and ≥ 99.3% from three and four images, respectively, when the C-arm is calibrated and the pose of the C-arm is known. The algorithm was also validated on phantom data sets successfully localizing the implanted seeds from four or five images. In a Phase-1 clinical trial, we were able to localize the implanted seeds from five intraoperative fluoroscopy images with 98.8% (STD=1.6) overall detection rate. PMID:19605321
Liu, Haibo; Cadaneanu, Radu M; Lai, Kevin; Zhang, Baohui; Huo, Lihong; An, Dong Sun; Li, Xinmin; Lewis, Michael S; Garraway, Isla P
2015-01-01
BACKGROUND Human fetal prostate buds appear in the 10th gestational week as solid cords, which branch and form lumens in response to androgen 1. Previous in vivo analysis of prostate epithelia isolated from benign prostatectomy specimens indicated that Epcam+CD44−CD49fHi basal cells possess efficient tubule initiation capability relative to other subpopulations 2. Stromal interactions and branching morphogenesis displayed by adult tubule-initiating cells (TIC) are reminiscent of fetal prostate development. In the current study, we evaluated in vivo tubule initiation by human fetal prostate cells and determined expression profiles of fetal and adult epithelial subpopulations in an effort to identify pathways used by TIC. METHODS Immunostaining and FACS analysis based on Epcam, CD44, and CD49f expression demonstrated the majority (99.9%) of fetal prostate epithelial cells (FC) were Epcam+CD44− with variable levels of CD49f expression. Fetal populations isolated via cell sorting were implanted into immunocompromised mice. Total RNA isolation from Epcam+CD44−CD49fHi FC, adult Epcam+CD44−CD49fHi TIC, Epcam+CD44+CD49fHi basal cells (BC), and Epcam+CD44−CD49fLo luminal cells (LC) was performed, followed by microarray analysis of 19 samples using the Affymetrix Gene Chip Human U133 Plus 2.0 Array. Data was analyzed using Partek Genomics Suite Version 6.4. Genes selected showed >2-fold difference in expression and P < 5.00E-2. Results were validated with RT-PCR. RESULTS Grafts retrieved from Epcam+CD44− fetal cell implants displayed tubule formation with differentiation into basal and luminal compartments, while only stromal outgrowths were recovered from Epcam- fetal cell implants. Hierarchical clustering revealed four distinct groups determined by antigenic profile (TIC, BC, LC) and developmental stage (FC). TIC and BC displayed basal gene expression profiles, while LC expressed secretory genes. FC had a unique profile with the most similarities to adult TIC. Functional, network, and canonical pathway identification using Ingenuity Pathway Analysis Version 7.6 compiled genes with the highest differential expression (TIC relative to BC or LC). Many of these genes were found to be significantly associated with prostate tumorigenesis. CONCLUSIONS Our results demonstrate clustering gene expression profiles of FC and adult TIC. Pathways associated with TIC are known to be deregulated in cancer, suggesting a cell-of-origin role for TIC versus re-emergence of pathways common to these cells in tumorigenesis. Prostate 75: 764–776, 2015. © The Authors. The Prostate, published by Wiley Periodicals, Inc. PMID:25663004
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamboglou, Nikolaos; Tselis, Nikolaos, E-mail: ntselis@hotmail.com; Baltas, Dimos
2013-03-01
Purpose: To report the clinical outcome of high-dose-rate (HDR) interstitial (IRT) brachytherapy (BRT) as sole treatment (monotherapy) for clinically localized prostate cancer. Methods and Materials: Between January 2002 and December 2009, 718 consecutive patients with clinically localized prostate cancer were treated with transrectal ultrasound (TRUS)-guided HDR monotherapy. Three treatment protocols were applied; 141 patients received 38.0 Gy using one implant in 4 fractions of 9.5 Gy with computed tomography-based treatment planning; 351 patients received 38.0 Gy in 4 fractions of 9.5 Gy, using 2 implants (2 weeks apart) and intraoperative TRUS real-time treatment planning; and 226 patients received 34.5 Gy,more » using 3 single-fraction implants of 11.5 Gy (3 weeks apart) and intraoperative TRUS real-time treatment planning. Biochemical failure was defined according to the Phoenix consensus, and toxicity was evaluated using Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 52.8 months. The 36-, 60-, and 96-month biochemical control and metastasis-free survival rates for the entire cohort were 97%, 94%, and 90% and 99%, 98%, and 97%, respectively. Toxicity was scored per event, with 5.4% acute grade 3 genitourinary and 0.2% acute grade 3 gastrointestinal toxicity. Late grade 3 genitourinary and gastrointestinal toxicities were 3.5% and 1.6%, respectively. Two patients developed grade 4 incontinence. No other instance of grade 4 or greater acute or late toxicity was reported. Conclusion: Our results confirm IRT-HDR-BRT is safe and effective as monotherapy for clinically localized prostate cancer.« less
Fog, L S; Nicholls, R; van Doom, T
2007-09-01
Low dose rate brachytherapy using implanted I-125 seeds as a monotherapy for prostate cancer is now in use in many hospitals. In contrast to fractionated brachytherapy treatments, where the effect of incorrect positioning of the source in one treatment fraction can be diminished by correcting the position in subsequent fractions, the I-125 seed implant is permanent, making correct positioning of the seeds in the prostate essential. The seeds are inserted into the prostate using needles. Correct configuration of seeds in the needles is essential in order to deliver the planned treatment. A comparison of an autoradiograph obtained by exposing film to the seed-loaded needles with the patient treatment plan is a valuable quality assurance tool. However, the time required to sufficiently expose Kodak XOMAT V film, currently used in this department is significant. This technical note presents the use of Kodak CR film for acquisition of the radiograph. The digital radiograph can be acquired significantly faster, has superior signal-to-noise ratio and contrast and has the usual benefits of digital film, e.g. a processing time which is shorter than that required for non-digital film, the possibility of image manipulation, possibility of paper printing and electronic storage.
A gEUD-based inverse planning technique for HDR prostate brachytherapy: Feasibility study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giantsoudi, D.; Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Boston, Massachusetts 02114; Baltas, D.
2013-04-15
Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the differentmore » dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D{sub 10} or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.« less
Wang, Guanghu; Dinkins, Michael; He, Qian; Zhu, Gu; Poirier, Christophe; Campbell, Andrew; Mayer-Proschel, Margot; Bieberich, Erhard
2012-01-01
Amyloid protein is well known to induce neuronal cell death, whereas only little is known about its effect on astrocytes. We found that amyloid peptides activated caspase 3 and induced apoptosis in primary cultured astrocytes, which was prevented by caspase 3 inhibition. Apoptosis was also prevented by shRNA-mediated down-regulation of PAR-4, a protein sensitizing cells to the sphingolipid ceramide. Consistent with a potentially proapoptotic effect of PAR-4 and ceramide, astrocytes surrounding amyloid plaques in brain sections of the 5xFAD mouse (and Alzheimer disease patient brain) showed caspase 3 activation and were apoptotic when co-expressing PAR-4 and ceramide. Apoptosis was not observed in astrocytes with deficient neutral sphingomyelinase 2 (nSMase2), indicating that ceramide generated by nSMase2 is critical for amyloid-induced apoptosis. Antibodies against PAR-4 and ceramide prevented amyloid-induced apoptosis in vitro and in vivo, suggesting that apoptosis was mediated by exogenous PAR-4 and ceramide, potentially associated with secreted lipid vesicles. This was confirmed by the analysis of lipid vesicles from conditioned medium showing that amyloid peptide induced the secretion of PAR-4 and C18 ceramide-enriched exosomes. Exosomes were not secreted by nSMase2-deficient astrocytes, indicating that ceramide generated by nSMase2 is critical for exosome secretion. Consistent with the ceramide composition in amyloid-induced exosomes, exogenously added C18 ceramide restored PAR-4-containing exosome secretion in nSMase2-deficient astrocytes. Moreover, isolated PAR-4/ceramide-enriched exosomes were taken up by astrocytes and induced apoptosis in the absence of amyloid peptide. Taken together, we report a novel mechanism of apoptosis induction by PAR-4/ceramide-enriched exosomes, which may critically contribute to Alzheimer disease. PMID:22532571
Amin, Hina; Nayak, Debasis; Ur Rasool, Reyaz; Chakraborty, Souneek; Kumar, Anmol; Yousuf, Khalid; Sharma, Parduman Raj; Ahmed, Zabeer; Sharma, Neelam; Magotra, Asmita; Mukherjee, Debaraj; Kumar, Lekha Dinesh; Goswami, Anindya
2016-05-01
Here, we provide evidences that natural product derivative 3-azido Withaferin A (3-AWA) abrogated EMT and invasion by modulating β-catenin localization and its transcriptional activity in the prostate as well as in breast cancer cells. This study, for the first time, reveals 3-AWA treatment consistently sequestered nuclear β-catenin and augmented its cytoplasmic pool as evidenced by reducing β-catenin transcriptional activity in these cells. Moreover, 3-AWA treatment triggered robust induction of pro-apoptotic intracellular Par-4, attenuated Akt activity and rescued Phospho-GSK3β (by Akt) to promote β-catenin destabilization. Further, our in vitro studies demonstrate that 3-AWA treatment amplified E-cadherin expression along with sharp downregulation of c-Myc and cyclin D1 proteins. Strikingly, endogenous Par-4 knock down by siRNA underscored 3-AWA mediated inhibition of nuclear β-catenin was Par-4 dependent and suppression of Par-4 activity, either by Bcl-2 or by Ras transfection, restored the nuclear β-catenin level suggesting Par-4 mediated β-catenin regulation was not promiscuous. In vivo results further demonstrated that 3-AWA was effective inhibitor of tumor growth and immunohistochemical studies indicated that increased expression of total β-catenin and decreased expression of phospho-β-catenin and Par-4 in breast cancer tissues as compared to normal breast tissue suggesting Par-4 and β-catenin proteins are mutually regulated and inversely co-related in normal as well as cancer condition. Thus, strategic regulation of intracellular Par-4 by 3-AWA in diverse cancers could be an effective tool to control cancer cell metastasis. Conclusively, this report puts forward a novel approach of controlling deregulated β-catenin signaling by 3-AWA induced Par-4 protein. © 2015 Wiley Periodicals, Inc.
2013-01-01
Background Prostate apoptosis response-4 (Par-4) is a tumor-suppressor protein that selectively activates and induces apoptosis in cancer cells, but not in normal cells. The cancer specific pro-apoptotic function of Par-4 is encoded in its centrally located SAC (Selective for Apoptosis induction in Cancer cells) domain (amino acids 137–195). The SAC domain itself is capable of nuclear entry, caspase activation, inhibition of NF-κB activity, and induction of apoptosis in cancer cells. However, the precise mechanism(s) of how the SAC domain is released from Par-4, in response to apoptotic stimulation, is not well explored. Results In this study, we demonstrate for the first time that sphingosine (SPH), a member of the sphingolipid family, induces caspase-dependant cleavage of Par-4, leading to the release of SAC domain containing fragment from it. Par-4 is cleaved at the EEPD131G site on incubation with caspase-3 in vitro, and by treating cells with several anti-cancer agents. The caspase-3 mediated cleavage of Par-4 is blocked by addition of the pan-caspase inhibitor z-VAD-fmk, caspase-3 specific inhibitor Ac-DEVD-CHO, and by introduction of alanine substitution for D131 residue. Moreover, suppression of SPH-induced Akt dephosphorylation also abrogated the caspase dependant cleavage of Par-4. Conclusion Evidence provided here shows that Par-4 is cleaved by caspase-3 during SPH-induced apoptosis. Cleavage of Par-4 leads to the generation of SAC domain containing fragment which may possibly be essential and sufficient to induce or augment apoptosis in cancer cells. PMID:23442976
USDA-ARS?s Scientific Manuscript database
Developing strategies to rapidly incorporate the fac-[MI(CO)3]+ (M = Re, 99mTc) core into biological targeting vectors is a growing realm in radiopharmaceutical development. This work presents the preparation of a novel isothiocyanate-functionalized bifunctional chelate based on 2,2´-dipicolylamine ...
Prostate thermal therapy with catheter-based ultrasound devices and MR thermal monitoring
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Nau, Will H.; Kinsey, Adam; Ross, Tony; Wootton, Jeff; Juang, Titania; Butts-Pauly, Kim; Ricke, Viola; Liu, Erin H.; Chen, Jing; Bouley, Donna M.; Van den Bosch, Maurice; Sommer, Graham
2007-02-01
Four types of transurethral applicators were devised for thermal ablation of prostate combined with MR thermal monitoring: sectored tubular transducer devices with directional heating patterns; planar and curvilinear devices with narrow heating patterns; and multi-sectored tubular devices capable of dynamic angular control without applicator movement. These devices are integrated with a 4 mm delivery catheter, incorporate an inflatable cooling balloon (10 mm OD) for positioning within the prostate and capable of rotation via an MR-compatible motor. Interstitial devices (2.4 mm OD) have been developed for percutaneous implantation with directional or dynamic angular control. In vivo experiments in canine prostate under MR temperature imaging were used to evaluate the heating technology and develop treatment control strategies. MR thermal imaging in a 0.5 T interventional MRI was used to monitor temperature and thermal dose in multiple slices through the target volume. Sectored tubular, planar, and curvilinear transurethral devices produce directional coagulation zones, extending 15-20 mm radial distance to the outer prostate capsule. Sequential rotation and modulated dwell time can conform thermal ablation to selected regions. Multi-sectored transurethral applicators can dynamically control the angular heating profile and target large regions of the gland in short treatment times without applicator manipulation. Interstitial implants with directional devices can be used to effectively ablate the posterior peripheral zone of the gland while protecting the rectum. The MR derived 52 °C and lethal thermal dose contours (t 43=240 min) allowed for real-time control of the applicators and effectively defined the extent of thermal damage. Catheter-based ultrasound devices, combined with MR thermal monitoring, can produce relatively fast and precise thermal ablation of prostate, with potential for treatment of cancer or BPH.
Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis
Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor
2011-01-01
Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use. PMID:21992346
Delayed-onset streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation.
Bayraktar, Zerrin; Kapran, Ziya; Bayraktar, Sükrü; Acar, Nur; Unver, Yaprak Banu; Gök, Kemran
2005-01-01
To report a case of delayed-onset Streptococcus pyogenes endophthalmitis following implantation of an Ahmed glaucoma valve. A 10-year-old patient presented with acute endophthalmitis 1 year after Ahmed glaucoma valve implantation. The conjunctiva and Tenon's capsule over the valve plate had been penetrated by one of the polypropylene fixation sutures. The valve was removed, and pars plana vitrectomy was performed. Vitreous specimens and removal of the discharge over the plate revealed Streptococcus pyogenes. This is the first documented case of Streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation. We think the conjunctival buttonhole caused by the polypropylene suture provided an entry site for the infection. (c) Japanese Ophthalmological Society 2005.
Small, Scott R; Hensley, Sarah E; Cook, Paige L; Stevens, Rebecca A; Rogge, Renee D; Meding, John B; Berend, Michael E
2017-02-01
Short-stemmed femoral components facilitate reduced exposure surgical techniques while preserving native bone. A clinically successful stem should ideally reduce risk for stress shielding while maintaining adequate primary stability for biological fixation. We asked (1) how stem-length changes cortical strain distribution in the proximal femur in a fit-and-fill geometry and (2) if short-stemmed components exhibit primary stability on par with clinically successful designs. Cortical strain was assessed via digital image correlation in composite femurs implanted with long, medium, and short metaphyseal fit-and-fill stem designs in a single-leg stance loading model. Strain was compared to a loaded, unimplanted femur. Bone-implant micromotion was then compared with reduced lateral shoulder short stem and short tapered-wedge designs in cyclic axial and torsional testing. Femurs implanted with short-stemmed components exhibited cortical strain response most closely matching that of the intact femur model, theoretically reducing the potential for proximal stress shielding. In micromotion testing, no difference in primary stability was observed as a function of reduced stem length within the same component design. Our findings demonstrate that within this fit-and-fill stem design, reduction in stem length improved proximal cortical strain distribution and maintained axial and torsional stability on par with other stem designs in a composite femur model. Short-stemmed implants may accommodate less invasive surgical techniques while facilitating more physiological femoral loading without sacrificing primary implant stability. Copyright © 2016 Elsevier Inc. All rights reserved.
2008-01-01
expressing Renilla luciferase and VEGF-C shRNA or irrelevant firefly luciferase shRNA (Ctrl) were implanted orthotopically as before. To determine the...on metastasis in Pten knockout model (Month 10-24): a) Generate Ubc/sVEGFR-3 and Ubc/ Renilla luciferase (RL) lentiviral vectors by subcloning...progression (month 10-12) c) Monitor efficiency of Ubc/lentiviral transduction and expression in Pten (-/-) prostate using optical imaging of Renilla
Real-time photoacoustic imaging of prostate brachytherapy seeds using a clinical ultrasound system.
Kuo, Nathanael; Kang, Hyun Jae; Song, Danny Y; Kang, Jin U; Boctor, Emad M
2012-06-01
Prostate brachytherapy is a popular prostate cancer treatment option that involves the permanent implantation of radioactive seeds into the prostate. However, contemporary brachytherapy procedure is limited by the lack of an imaging system that can provide real-time seed-position feedback. While many other imaging systems have been proposed, photoacoustic imaging has emerged as a potential ideal modality to address this need, since it could easily be incorporated into the current ultrasound system used in the operating room. We present such a photoacoustic imaging system built around a clinical ultrasound system to achieve the task of visualizing and localizing seeds. We performed several experiments to analyze the effects of various parameters on the appearance of brachytherapy seeds in photoacoustic images. We also imaged multiple seeds in an ex vivo dog prostate phantom to demonstrate the possibility of using this system in a clinical setting. Although still in its infancy, these initial results of a photoacoustic imaging system for the application of prostate brachytherapy seed localization are highly promising.
McCormick, D L; Rao, K V; Dooley, L; Steele, V E; Lubet, R A; Kelloff, G J; Bosland, M C
1998-08-01
The influence of chemical carcinogen, hormonal stimulation, and chronic dietary administration of the synthetic retinoid, N-(4-hydroxyphenyl)-all-trans-retinamide (4-HPR), on the induction of prostate cancer in male Wistar-Unilever rats was determined. Three different tumor induction regimens were used: (a) a single i.v. dose of 50 mg of N-methyl-N-nitrosourea (MNU) per kg body weight, followed by chronic androgen stimulation via s.c. implantation of two silastic capsules containing 40 mg testosterone each; (b) a single i.v. dose of 50 mg of MNU per kg body weight (no testosterone treatment); and (c) chronic androgen stimulation with implanted testosterone capsules (no MNU treatment). In a fourth series of animals, the incidence of spontaneous prostate tumors was determined in groups of rats receiving neither carcinogen nor hormone stimulation. Within each series, parallel groups of animals were fed a control (vehicle-supplemented) diet or control diet supplemented with 4-HPR beginning 1 day after carcinogen administration; retinoid administration was continuous until termination of the study at 450 days. The incidence of accessory sex gland cancer in rats treated sequentially with MNU + testosterone was >60%, in comparison with cancer incidences of <20% in rats receiving MNU only and <5% in rats treated with testosterone only. No spontaneous accessory sex gland tumors were observed in rats receiving no carcinogen and no testosterone. Tumor induction in the accessory sex glands by MNU + testosterone was relatively specific for the prostate: the incidence of carcinoma of the dorsolateral/anterior prostate was more than 5-fold greater than the incidence of cancer present only in the seminal vesicle. 4-HPR conferred no protection against cancer induction in the prostate by any regimen of MNU and/or testosterone. These results demonstrate the importance of both carcinogen exposure and hormone stimulation on the induction of neoplasia in the prostate of Wistar-Unilever rats.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nuñez-Cumplido, E., E-mail: ejnc-mccg@hotmail.com; Hernandez-Armas, J.; Perez-Calatayud, J.
2015-08-15
Purpose: In clinical practice, specific air kerma strength (S{sub K}) value is used in treatment planning system (TPS) permanent brachytherapy implant calculations with {sup 125}I and {sup 103}Pd sources; in fact, commercial TPS provide only one S{sub K} input value for all implanted sources and the certified shipment average is typically used. However, the value for S{sub K} is dispersed: this dispersion is not only due to the manufacturing process and variation between different source batches but also due to the classification of sources into different classes according to their S{sub K} values. The purpose of this work is tomore » examine the impact of S{sub K} dispersion on typical implant parameters that are used to evaluate the dose volume histogram (DVH) for both planning target volume (PTV) and organs at risk (OARs). Methods: The authors have developed a new algorithm to compute dose distributions with different S{sub K} values for each source. Three different prostate volumes (20, 30, and 40 cm{sup 3}) were considered and two typical commercial sources of different radionuclides were used. Using a conventional TPS, clinically accepted calculations were made for {sup 125}I sources; for the palladium, typical implants were simulated. To assess the many different possible S{sub K} values for each source belonging to a class, the authors assigned an S{sub K} value to each source in a randomized process 1000 times for each source and volume. All the dose distributions generated for each set of simulations were assessed through the DVH distributions comparing with dose distributions obtained using a uniform S{sub K} value for all the implanted sources. The authors analyzed several dose coverage (V{sub 100} and D{sub 90}) and overdosage parameters for prostate and PTV and also the limiting and overdosage parameters for OARs, urethra and rectum. Results: The parameters analyzed followed a Gaussian distribution for the entire set of computed dosimetries. PTV and prostate V{sub 100} and D{sub 90} variations ranged between 0.2% and 1.78% for both sources. Variations for the overdosage parameters V{sub 150} and V{sub 200} compared to dose coverage parameters were observed and, in general, variations were larger for parameters related to {sup 125}I sources than {sup 103}Pd sources. For OAR dosimetry, variations with respect to the reference D{sub 0.1cm{sup 3}} were observed for rectum values, ranging from 2% to 3%, compared with urethra values, which ranged from 1% to 2%. Conclusions: Dose coverage for prostate and PTV was practically unaffected by S{sub K} dispersion, as was the maximum dose deposited in the urethra due to the implant technique geometry. However, the authors observed larger variations for the PTV V{sub 150}, rectum V{sub 100}, and rectum D{sub 0.1cm{sup 3}} values. The variations in rectum parameters were caused by the specific location of sources with S{sub K} value that differed from the average in the vicinity. Finally, on comparing the two sources, variations were larger for {sup 125}I than for {sup 103}Pd. This is because for {sup 103}Pd, a greater number of sources were used to obtain a valid dose distribution than for {sup 125}I, resulting in a lower variation for each S{sub K} value for each source (because the variations become averaged out statistically speaking)« less
Bernoulli, J; Konkol, Y; Vuorikoski, H; Yatkin, E
2014-04-01
In the hormone-dependent prostate inflammation model induced by implantation of slow-releasing pellets (50 mg testosterone and 5 mg estradiol) to Noble male rats, intragastric administration of Afala at a dose of 7.5 ml/kg for 18 weeks reduced the number of inflamed prostatic acini. The effect of afala was comparable with that of antiestrogen ICI 182,780 (3 mg/kg subcutaneously twice a week for 18 weeks). Prolonged treatment with hormones in high doses induced severe inflammation of the prostate tissue, which was not terminated by the test preparations. As differentiated from the antiestrogen ICI 182,780, afala did not induce body weight gain and decrease in pituitary weight in experimental animals in comparison with the control group.
Liu, Haibo; Cadaneanu, Radu M; Lai, Kevin; Zhang, Baohui; Huo, Lihong; An, Dong Sun; Li, Xinmin; Lewis, Michael S; Garraway, Isla P
2015-05-01
Human fetal prostate buds appear in the 10th gestational week as solid cords, which branch and form lumens in response to androgen 1. Previous in vivo analysis of prostate epithelia isolated from benign prostatectomy specimens indicated that Epcam⁺ CD44⁻ CD49f(Hi) basal cells possess efficient tubule initiation capability relative to other subpopulations 2. Stromal interactions and branching morphogenesis displayed by adult tubule-initiating cells (TIC) are reminiscent of fetal prostate development. In the current study, we evaluated in vivo tubule initiation by human fetal prostate cells and determined expression profiles of fetal and adult epithelial subpopulations in an effort to identify pathways used by TIC. Immunostaining and FACS analysis based on Epcam, CD44, and CD49f expression demonstrated the majority (99.9%) of fetal prostate epithelial cells (FC) were Epcam⁺ CD44⁻ with variable levels of CD49f expression. Fetal populations isolated via cell sorting were implanted into immunocompromised mice. Total RNA isolation from Epcam⁺ CD44⁻ CD49f(Hi) FC, adult Epcam⁺ CD44⁻ CD49f(Hi) TIC, Epcam⁺ CD44⁺ CD49f(Hi) basal cells (BC), and Epcam⁺ CD44⁻ CD49f(Lo) luminal cells (LC) was performed, followed by microarray analysis of 19 samples using the Affymetrix Gene Chip Human U133 Plus 2.0 Array. Data was analyzed using Partek Genomics Suite Version 6.4. Genes selected showed >2-fold difference in expression and P < 5.00E-2. Results were validated with RT-PCR. Grafts retrieved from Epcam⁺ CD44⁻ fetal cell implants displayed tubule formation with differentiation into basal and luminal compartments, while only stromal outgrowths were recovered from Epcam- fetal cell implants. Hierarchical clustering revealed four distinct groups determined by antigenic profile (TIC, BC, LC) and developmental stage (FC). TIC and BC displayed basal gene expression profiles, while LC expressed secretory genes. FC had a unique profile with the most similarities to adult TIC. Functional, network, and canonical pathway identification using Ingenuity Pathway Analysis Version 7.6 compiled genes with the highest differential expression (TIC relative to BC or LC). Many of these genes were found to be significantly associated with prostate tumorigenesis. Our results demonstrate clustering gene expression profiles of FC and adult TIC. Pathways associated with TIC are known to be deregulated in cancer, suggesting a cell-of-origin role for TIC versus re-emergence of pathways common to these cells in tumorigenesis. © 2015 The Authors. The Prostate, published by Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaudet, Marc; Vigneault, Eric; Aubin, Sylviane
2010-05-01
Purpose: Using real-time intraoperative inverse-planned permanent seed prostate implant (RTIOP/PSI), multiple core biopsy maps, and three-dimensional ultrasound guidance, we planned a boost volume (BV) within the prostate to which hyperdosage was delivered selectively. The aim of this study was to investigate the potential negative effects of such a procedure. Methods and Materials: Patients treated with RTIOP/PSI for localized prostate cancer with topographic biopsy results received an intraprostatic boost (boost group [BG]). They were compared with patients treated with a standard plan (reference group [RG]). Plans were generated using a simulated annealing inverse planning algorithm. Prospectively recorded urinary, rectal, and sexualmore » toxicities and dosimetric parameters were compared between groups. Results: The study included 120 patients treated with boost technique who were compared with 70 patients treated with a standard plan. Boost technique did not significantly change the number of seeds (55.1/RG vs. 53.6/BG). The intraoperative prostate V150 was slightly higher in BG (75.2/RG vs. 77.2/BG, p = 0.039). Urethra V100, urethra D90, and rectal D50 were significantly lower in the BG. No significant differences were seen in acute or late urinary, rectal, or sexual toxicities. Conclusions: Because there were no differences between the groups in acute and late toxicities, we believe that BV can be planned and delivered to the dominant intraprostatic lesion without increasing toxicity. It is too soon to say whether a boost technique will ultimately increase local control.« less
Usmani, Nawaid; Leong, Nelson; Martell, Kevin; Lan, Lanna; Ghosh, Sunita; Pervez, Nadeem; Pedersen, John; Yee, Don; Murtha, Albert; Amanie, John; Sloboda, Ron; Murray, David; Parliament, Matthew
2014-01-01
To identify clinical, dosimetric, and genetic factors that are associated with late urinary toxicity after a (125)I prostate brachytherapy implant. Genomic DNA from 296 men treated with (125)I prostate brachytherapy monotherapy was extracted from saliva samples for this study. A retrospective database was compiled including clinical, dosimetric, and toxicity data for this cohort of patients. Fourteen candidate single-nucleotide polymorphism (SNPs) from 13 genes (TP53, ERCC2, GSTP1, NOS, TGFβ1, MSH6, RAD51, ATM, LIG4, XRCC1, XRCC3, GSTA1, and SOD2) were tested in this cohort for correlations with toxicity. This study identified 217 men with at least 2 years of followup. Of these, 39 patients developed Grade ≥2 late urinary complications with a transurethral resection of prostate, urethral stricture, gross hematuria, or a sustained increase in their International Prostate Symptom Score. The only clinical or dosimetric factor that was associated with late urinary toxicity was age (p = 0.02). None of the 14 SNPs tested in this study were associated with late urinary toxicity in the univariate analysis. This study identified age as the only variable being associated with late urinary toxicity. However, the small sample size and the candidate gene approach used in this study mean that further investigations are essential. Genome-wide association studies are emerging as the preferred approach for future radiogenomic studies to overcome the limitations from a candidate gene approach. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
Shakir, Shakir I; Udrescu, Corina; Enachescu, Ciprian; Rouviere, Olivier; Arion, Simona; Caraivan, Ionela; Chapet, Olivier
2016-11-01
The objective of the study was to verify the stability of gold markers in the prostatic bed (PB) during salvage radiotherapy. Seven patients, diagnosed with a macroscopic nodule visible on MRI, underwent targeted MRI-guided biopsies. Three gold markers were implanted into the PB close to the relapsing nodule for CT/MRI fusion. A dose of 60Gy was delivered using IMRT to the PB followed by a dose escalation up to 72Gy to the macroscopic nodule. Daily anterior and left-lateral kV-images were acquired for repositioning. The coordinates of the center of each marker were measured on the two kV-images. The distance variations (Dvar) of the markers in the first session and the subsequent ones were compared. No marker was lost during treatment. The average distance between markers was 7.8mm. The average Dvar was 0.8mm, in absolute value. A total of 380/528 (72%) Dvar were ⩽1mm. A Dvar greater than 2mm was observed in 5.7% of measurements, with a maximum value of 4.8mm. Despite the absence of the prostate, the implantation of gold markers in the PB remains feasible, with Dvar often less than 2mm, and could be used to develop new approaches of salvage focal radiotherapy on the macroscopic relapse after prostatectomy. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Mehrmohammadi, Mohammad; Alizad, Azra; Kinnick, Randall R.; Davis, Brian J.; Fatemi, Mostafa
2013-03-01
Effective brachytherapy procedures require precise placement of radioactive seeds in the prostate. Currently, transrectal ultrasound (TRUS) imaging is one of the main intraoperative imaging modalities to assist physicians in placement of brachytherapy seeds. However, the seed detection rate with TRUS is poor mainly because ultrasound imaging is highly sensitive to variations in seed orientation. The purpose of this study is to investigate the abilities of a new acoustic radiation force imaging modality, vibro-acoustography (VA), equipped with a 1.75D array transducer and implemented on a customized clinical ultrasound scanner, to image and localize brachytherapy seeds in prostatic tissue. To perform experiments, excised cadaver prostate specimens were implanted with dummy brachytherapy seeds, and embedded in tissue mimicking gel to simulate the properties of the surrounding soft tissues. The samples were scanned using the VA system and the resulting VA signals were used to reconstruct VA images at several depths inside the tissue. To further evaluate the performance of VA in detecting seeds, X-ray computed tomography (CT) images of the same tissue sample, were obtained and used as a gold-standard to compare the number of seeds detected by the two methods. Our results indicate that VA is capable of imaging of brachytherapy seeds with accuracy and high contrast, and can detect a large percentage of the seeds implanted within the tissue samples.
Arctigenin inhibits prostate tumor cell growth in vitro and in vivo
Wang, Piwen; Solorzano, Walter; Diaz, Tanya; Magyar, Clara E.; Henning, Susanne M.; Vadgama, Jaydutt V.
2017-01-01
The low bioavailability of most phytochemicals limits their translation to humans. We investigated whether arctigenin, a novel anti-inflammatory lignan from the seeds of Arctium lappa, has favorable bioavailability/potency against prostate cancer. The anticarcinogenic activity of arctigenin was investigated both in vitro using the androgen-sensitive LNCaP and LAPC-4 human prostate cancer cells and pre-malignant WPE1-NA22 cells, and in vivo using xenograft mouse models. Arctigenin at lower doses (< 2μM) significantly inhibited the proliferation of LNCaP and LAPC-4 cells by 30-50% at 48h compared to control, and inhibited WPE1-NA22 cells by 75%, while did not affect normal prostate epithelial cells. Male severe combined immunodeficiency (SCID) mice were implanted subcutaneously with LAPC-4 cells for in vivo studies. In one experiment, the intervention started one week after tumor implantation. Mice received arctigenin at 50mg/kg (LD) or 100mg/kg (HD) b.w. daily or vehicle control by oral gavage. After 6 weeks, tumor growth was inhibited by 50% (LD) and 70% (HD) compared to control. A stronger tumor inhibitory effect was observed in a second experiment where arctigenin intervention started two weeks prior to tumor implantation. Arc was detectable in blood and tumors in Arc groups, with a mean value up to 2.0 μM in blood, and 8.3 nmol/g tissue in tumors. Tumor levels of proliferation marker Ki67, total and nuclear androgen receptor, and growth factors including VEGF, EGF, and FGF-β were significantly decreased by Arc, along with an increase in apoptosis marker of Bax/Bcl-2 ratio. Genes responsive to arctigenin were identified including TIMP3 and ZNF185, and microRNAs including miR-126-5p, and miR-21-5p. This study provides the first in vivo evidence of the strong anticancer activity of arctigenin in prostate cancer. The effective dose of arctigenin in vitro is physiologically achievable in vivo, which provides a high promise in its translation to human application. PMID:29062885
Arctigenin inhibits prostate tumor cell growth in vitro and in vivo.
Wang, Piwen; Solorzano, Walter; Diaz, Tanya; Magyar, Clara E; Henning, Susanne M; Vadgama, Jaydutt V
2017-06-01
The low bioavailability of most phytochemicals limits their translation to humans. We investigated whether arctigenin, a novel anti-inflammatory lignan from the seeds of Arctium lappa , has favorable bioavailability/potency against prostate cancer. The anticarcinogenic activity of arctigenin was investigated both in vitro using the androgen-sensitive LNCaP and LAPC-4 human prostate cancer cells and pre-malignant WPE1-NA22 cells, and in vivo using xenograft mouse models. Arctigenin at lower doses (< 2μM) significantly inhibited the proliferation of LNCaP and LAPC-4 cells by 30-50% at 48h compared to control, and inhibited WPE1-NA22 cells by 75%, while did not affect normal prostate epithelial cells. Male severe combined immunodeficiency (SCID) mice were implanted subcutaneously with LAPC-4 cells for in vivo studies. In one experiment, the intervention started one week after tumor implantation. Mice received arctigenin at 50mg/kg (LD) or 100mg/kg (HD) b.w. daily or vehicle control by oral gavage. After 6 weeks, tumor growth was inhibited by 50% (LD) and 70% (HD) compared to control. A stronger tumor inhibitory effect was observed in a second experiment where arctigenin intervention started two weeks prior to tumor implantation. Arc was detectable in blood and tumors in Arc groups, with a mean value up to 2.0 μM in blood, and 8.3 nmol/g tissue in tumors. Tumor levels of proliferation marker Ki67, total and nuclear androgen receptor, and growth factors including VEGF, EGF, and FGF-β were significantly decreased by Arc, along with an increase in apoptosis marker of Bax/Bcl-2 ratio. Genes responsive to arctigenin were identified including TIMP3 and ZNF185, and microRNAs including miR-126-5p, and miR-21-5p. This study provides the first in vivo evidence of the strong anticancer activity of arctigenin in prostate cancer. The effective dose of arctigenin in vitro is physiologically achievable in vivo , which provides a high promise in its translation to human application.
Liu, S; Liu, Y-P; Yue, D-M; Liu, G-J
2014-03-01
Treating bone cancer pain continues to be a major clinical challenge, and the underlying mechanisms of bone cancer pain remain elusive. Protease-activated receptor 2 (PAR2) has been reported to be involved in neurogenic inflammation, nociceptive pain and hyperalgesia. Here, we investigated the role of PAR2 in bone cancer pain development. Expression of PAR2, mechanical allodynia, thermal hyperalgesia and neurochemical alterations induced by bone cancer pain were analysed in male, adult C3H/HeJ mice with tumour cell implantation (TCI). To investigate the contribution of PAR2 to bone cancer pain, PAR2 antagonist peptide and PAR2 knockout mice were used. TCI produced bone cancer-related pain behaviours. Production and persistence of these pain behaviours were well correlated with TCI-induced up-regulation of PAR2 in sciatic nerve and dorsal root ganglia (DRG). PAR2 knockout and spinal administration of PAR2 antagonist peptide prevented and/or reversed bone cancer-related pain behaviours and associated neurochemical changes in DRG and dorsal horn (DH). TCI also induced proteases release in tumour-bearing tibia, sciatic nerve and DRG. Plantar injection of supernatant from sarcoma cells induced PAR2 up-regulation and intracellular calcium [Ca(2+) ]i increase in DRG, and calcitonin gene-related peptide accumulation in DH, as well as significant thermal and mechanical hyperalgesia, which were all in PAR2-dependent manners. These findings suggest that PAR2 may be a key mediator for peripheral sensitization of bone cancer pain. Inhibiting PAR2 activation, especially during the early phase, may be a new therapy for preventing/suppressing development of bone cancer pain. © 2013 European Pain Federation - EFIC®
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapur, P; Ford, J; Moghanaki, D
Purpose: To evaluate the Medical Event (ME) criteria for I-125 prostate implants based on the assessment of post implant dosimetry on “Day0”/“Day30” imaging. The new ME criteria do not mandate a timeframe for this assessment. The compliance criteria are: more than 80% of the activity from the written directive for treatment site (TS) must be implanted inside TS, and doses to 1cc of either uninvolved rectum (D1-UR) or uninvolved bladder (D1-UB), or 2cc of other non-specified tissue (D2-UT) must be less than 150% of the planned dose. Methods: “Day0”/“Day30” post-implant analyses for 25 patients were evaluated. Treatment plans had amore » peripheral loading pattern with 2 core needles placed at least 10 mm away from urethra, with several seeds planned outside of the prostate for adequate target coverage. TS were a uniform 5 mm expansion of the prostate, except posteriorly (no expansion). Results: “Day0”/“Day30”analyses found no MEs. The relative changes for D1-UR, D1-UB, and D2-UT were (ranges): [−37.0, 38.2]%, [−96.5, 74.7]%, and [−41.2, 37.7]%. Furthermore, changes did not correlate with prostate volume changes of −18.7% [σ:16.0%, range:−60.5%, +6.4%]. These unfavorable changes did not lead to ME at “Day30” because these values were generally well below 150% at “Day0”. However, D2-UT dose values exceeded those for D1-UR and D1-UB at both “Day0”/“Day30”. Conclusion: The total activity was relatively insensitive to changes in target volume from “Day0” to ”Day30”. The dose metrics of interest, albeit susceptible to large, often unfavorable changes, remained less than the 150% threshold. Data from this study suggest that “Day0” can be used for the regulatory compliance evaluation. However, further evaluation at “Day30” is advisable if D2-UT is 110% or above (based on the largest D2-UT increase of 37.7% observed in this patient population). Future rigorous statistical analysis of a larger cohort will afford a refinement of this recommendation.« less
SU-F-P-40: Analysis of Pelvic Lymph Node Margin Using Prostate Fiducial Markers, for SBRT Treatments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torres, J; Castro Pena, P; Garrigo, E
2016-06-15
Purpose: The use of fiducials markers in prostate treatment allows a precise localization of this volume. Typical prostate SBRT margins with fiducials markers are 5mm in all directions, except toward the rectum, where 3mm is used. For some patients nearby pelvic lymph nodes with 5mm margin need to be irradiate assuming that its localization is linked to the prostate fiducial markers instead of bony anatomy. The purpose of this work was to analyze the geometric impact of locate the lymph node regions through the patient positioning by prostate fiducial markers. Methods: 10 patients with prostate SBRT with lymph nodes irradiationmore » were selected. Each patient had 5 implanted titanium fiducial markers. A Novalis TX (BrainLAB-Varian) with ExacTrac and aSi1000 portal image was used. Treatment plan uses 11 beams with a dose prescription (D95%) of 40Gy to the prostate and 25Gy to the lymph node in 5 fractions. Daily positioning was carried out by ExacTrac system based on the implanted fiducials as the reference treatment position; further position verification was performed using the ExacTrac and two portal images (gantry angle 0 and 90) based on bony structures. Comparison between reference position with bony based ExacTrac and portal image localization, was done for each treatment fraction Results: A total of 50 positioning analysis were done. The average discrepancy between reference treatment position and ExacTrac based on bony anatomy (pubic area) was 4.2mm [0.3; 11.2]. The discrepancy was <5mm in 61% of the cases and <9mm in 92%. Using portal images the average discrepancy was 3.7mm [0.0; 11.1]. The discrepancy was <5mm in 69% of the cases and <9mm in 96%. Conclusion: Localizing lymph node by prostate fiducial markers may produce large discrepancy as large as 11mm compared to bony based localization. Dosimetric impact of this discrepancy should be studied.« less
Pérez-Morales, Marcel; López-Colomé, Ana María; Méndez-Díaz, Mónica; Ruiz-Contreras, Alejandra E; Prospéro-García, Oscar
2014-08-22
Stimulation of the protease-activated receptor 1 (PAR1) in vitro, was shown to induce synaptic retrograde signaling through the endocannabinoid 2-arachidonoylglycerol (2-AG) synthesis and activation of the cannabinoid receptor type 1 (CB1R). The activation of PAR1 by the agonist S1820 in the lateral hypothalamus (LH) increases rapid eye movement sleep (REMS) and food intake in rats, and both effects are prevented by the CB1R inverse agonist AM251. In the present study, we implanted rats with electrodes and with cannulae aimed bilaterally to the LH. We administered tetrahydrolipstatin (THL), an inhibitor of the diacylglycerol lipase (DAGL), the enzyme responsible for 2-AG synthesis, to evaluate the sleep-wake cycle and food ingestion. THL in the LH readily prevented the increase in REMS and food intake induced by PAR1 stimulation, further supporting 2-AG as an upstream activator of PAR1. Our results demonstrate that the effect of PAR1 on REMS and food intake is blocked by the inhibition of DAGL, further suggesting that PAR1 stimulation in the lateral hypothalamus of rats induces an increase in sleep and food intake through 2-AG. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Bekeredjian, Raffi; Bodingbauer, Dorothea; Hofmann, Nina P; Greiner, Sebastian; Schuetz, Moritz; Geis, Nicolas A; Kauczor, Hans U; Bryant, Mark; Chorianopoulos, Emmanuel; Pleger, Sven T; Mereles, Derliz; Katus, Hugo A; Korosoglou, Grigorios
2015-03-01
To investigate if the extent of aortic valve calcification is associated with postprocedural prosthesis eccentricity and paravalvular regurgitation (PAR) in patients undergoing transcatheter aortic valve implantation (TAVI). Cardiac computed tomography angiography (CCTA) was performed before and 3 months after TAVI in 46 patients who received the self-expanding CoreValve and in 22 patients who underwent balloon-expandable Edwards Sapien XT implantation. Aortic annulus calcification was measured with CCTA prior to TAVI and prosthesis eccentricity was assessed with post-TAVI CCTA. Standard echocardiography was also performed in all patients at 3-month follow-up exam. Annulus eccentricity was reduced during TAVI using both implantation systems (from 0.23 ± 0.06 to 0.18 ± 0.07 using CoreValve and from 0.20 ± 0.07 to 0.05 ± 0.03 using Edwards Sapien XT; P<.001 for both). With Edwards Sapien XT, eccentricity reduction at the level of the aortic annulus was significantly higher compared with CoreValve (P<.001). Annulus eccentricity after CoreValve use was significantly related to absolute valve calcification and to valve calcification indexed to body surface area (BSA) (r = 0.48 and 0.50, respectively; P<.001 for both). Furthermore, a significant association was observed between aortic valve calcification and PAR (P<.01 by ANOVA) in patients who received CoreValve. Using ROC analysis, a cut-off value over 913 mm² aortic valve calcification predicted the occurrence of moderate or severe PAR with a sensitivity of 92% and a specificity of 63% (area under the curve = 0.75). Furthermore, multivariable analysis showed that aortic valve calcification was a robust predictor of postprocedural eccentricity and PAR, independent of the aortic annulus size and native valve eccentricity and of CoreValve prosthesis size (adjusted r = 0.46 and 0.50, respectively; P<.01 for both). Such associations were not present with the Edwards Sapien XT system. The extent of native aortic annulus calcification is predictive for postprocedural prosthesis eccentricity and PAR, which is an important marker for long-term mortality in patients undergoing TAVI. This observation applies for the CoreValve, but not for the Edwards Sapien XT valve.
Lu, C; Li, J-Y; Ge, Z; Zhang, L; Zhou, G-P
2013-01-01
Although the intensification of therapy for children with T-cell acute lymphoblastic leukemia (T-ALL) has substantially improved clinical outcomes, T-ALL remains an important challenge in pediatric oncology. Here, we report that the cooperative synergy between prostate apoptosis response factor-4 (Par-4) and THAP1 induces cell cycle and apoptosis regulator 1 (CCAR1) gene expression and cellular apoptosis in human T-ALL cell line Jurkat cells, CEM cells and primary cultured neoplastic T lymphocytes from children with T-ALL. Par-4 and THAP1 collaborated to activate the promoter of CCAR1 gene. Mechanistic investigations revealed that Par-4 and THAP1 formed a protein complex by the interaction of their carboxyl termini, and THAP1 bound to CCAR1 promoter though its zinc-dependent DNA-binding domain at amino terminus. Par-4/THAP1 complex and Notch3 competitively bound to CCAR1 promoter and competitively modulated alternative pre-mRNA splicing of CCAR1, which resulted in two different transcripts and played an opposite role in T-ALL cell survival. Despite Notch3 induced a shift splicing from the full-length isoform toward a shorter form of CCAR1 mRNA by splicing factor SRp40 and SRp55, Par-4/THAP1 complex strongly antagonized this inductive effect. Our finding revealed a mechanistic rationale for Par-4/THAP1-induced apoptosis in T-ALL cells that would be of benefit to develop a new therapy strategy for T-ALL. PMID:23975424
Parajuli, Keshab Raj; Zhang, Qiuyang; Liu, Sen; You, Zongbing
2016-01-01
Aminomethylphosphonic acid (AMPA) has been shown to inhibit prostate cancer cell growth in vitro. The purpose of the present study was to determine if AMPA could inhibit growth and metastasis of prostate cancer in vivo. Human prostate cancer PC-3-LacZ-luciferase cells were implanted into the ventral lateral lobes of the prostate in 39 athymic Nu/Nu nude male mice. Seven days later, mice were randomized into the control group (n = 14, treated intraperitoneally with phosphate buffered saline), low dose group (n = 10, treated intraperitoneally with AMPA at 400 mg/kg body weight/day), and high dose group (n = 15, treated intraperitoneally with AMPA at 800 mg/kg body weight/day). Tumor growth and metastasis were examined every 4-7 days by bioluminescence imaging of live mice. We found that AMPA treatment significantly inhibited growth and metastasis of orthotopic xenograft prostate tumors and prolonged the survival time of the mice. AMPA treatment decreased expression of BIRC2 and activated caspase 3, leading to increased apoptosis in the prostate tumors. AMPA treatment decreased expression of cyclin D1. AMPA treatment also reduced angiogenesis in the prostate tumors. Taken together, these results demonstrate that AMPA can inhibit prostate cancer growth and metastasis, suggesting that AMPA may be developed into a therapeutic agent for the treatment of prostate cancer. PMID:26840261
Parajuli, Keshab Raj; Zhang, Qiuyang; Liu, Sen; You, Zongbing
2016-03-01
Aminomethylphosphonic acid (AMPA) has been shown to inhibit prostate cancer cell growth in vitro. The purpose of the present study was to determine if AMPA could inhibit growth and metastasis of prostate cancer in vivo. Human prostate cancer PC-3-LacZ-luciferase cells were implanted into the ventral lateral lobes of the prostate in 39 athymic Nu/Nu nude male mice. Seven days later, mice were randomized into the control group (n = 14, treated intraperitoneally with phosphate buffered saline), low dose group (n = 10, treated intraperitoneally with AMPA at 400 mg/kg body weight/day), and high dose group (n = 15, treated intraperitoneally with AMPA at 800 mg/kg body weight/day). Tumor growth and metastasis were examined every 4-7 days by bioluminescence imaging of live mice. We found that AMPA treatment significantly inhibited growth and metastasis of orthotopic xenograft prostate tumors and prolonged the survival time of the mice. AMPA treatment decreased expression of BIRC2 and activated caspase 3, leading to increased apoptosis in the prostate tumors. AMPA treatment decreased expression of cyclin D1. AMPA treatment also reduced angiogenesis in the prostate tumors. Taken together, these results demonstrate that AMPA can inhibit prostate cancer growth and metastasis, suggesting that AMPA may be developed into a therapeutic agent for the treatment of prostate cancer.
Kolozsvári, Bence L; Losonczy, Gergely; Pásztor, Dorottya; Fodor, Mariann
2017-01-13
Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and refractive predictability in patients with a previous vitreoretinal surgery can be as good as in uncomplicated cases.
L'etude de l'InP et du GaP suite a l'implantation ionique de Mn et a un recuit thermique
NASA Astrophysics Data System (ADS)
Bucsa, Ioan Gigel
Cette these est dediee a l'etude des materiaux InMnP et GaMnP fabriques par implantation ionique et recuit thermique. Plus precisement nous avons investigue la possibilite de former par implantation ionique des materiaux homogenes (alliages) de InMnP et GaMnP contenant de 1 a 5 % atomiques de Mn qui seraient en etat ferromagnetique, pour des possibles applications dans la spintronique. Dans un premier chapitre introductif nous donnons les motivations de cette recherche et faisons une revue de la litterature sur ce sujet. Le deuxieme chapitre decrit les principes de l'implantation ionique, qui est la technique utilisee pour la fabrication des echantillons. Les effets de l'energie, fluence et direction du faisceau ionique sur le profil d'implantation et la formation des dommages seront mis en evidence. Aussi dans ce chapitre nous allons trouver des informations sur les substrats utilises pour l'implantation. Les techniques experimentales utilisees pour la caracterisation structurale, chimique et magnetique des echantillons, ainsi que leurs limitations sont presentees dans le troisieme chapitre. Quelques principes theoriques du magnetisme necessaires pour la comprehension des mesures magnetiques se retrouvent dans le chapitre 4. Le cinquieme chapitre est dedie a l'etude de la morphologie et des proprietes magnetiques des substrats utilises pour implantation et le sixieme chapitre, a l'etude des echantillons implantes au Mn sans avoir subi un recuit thermique. Notamment nous allons voir dans ce chapitre que l'implantation de Mn a plus que 1016 ions/cm 2 amorphise la partie implantee du materiau et le Mn implante se dispose en profondeur sur un profil gaussien. De point de vue magnetique les atomes implantes se trouvent dans un etat paramagnetique entre 5 et 300 K ayant le spin 5/2. Dans le chapitre 7 nous presentons les proprietes des echantillons recuits a basses temperatures. Nous allons voir que dans ces echantillons la couche implantee est polycristalline et les atomes de Mn sont toujours dans un etat paramagnetique. Dans les chapitres 8 et 9, qui sont les plus volumineux, nous presentons les resultats des mesures sur les echantillons recuits a hautes temperatures: il s'agit d'InP et du GaP implantes au Mn, dans le chapitre 8 et d'InP co-implante au Mn et au P, dans le chapitre 9. D'abord, dans le chapitre 8 nous allons voir que le recuit a hautes temperatures mene a une recristallisation epitaxiale du InMnP et du GaMnP; aussi la majorite des atomes de Mn se deplacent vers la surface a cause d'un effet de segregation. Dans les regions de la surface, concentres en Mn, les mesures XRD et TEM identifient la formation de MnP et d'In cristallin. Les mesures magnetiques identifient aussi la presence de MnP ferromagnetique. De plus dans ces mesures on trouve qu'environ 60 % du Mn implante est en etat paramagnetique avec la valeur du spin reduite par rapport a celle trouvee dans les echantillons non-recuits. Dans les echantillons InP co-implantes au Mn et au P la recristallisation est seulement partielle mais l'effet de segregation du Mn a la surface est beaucoup reduit. Dans ce cas plus que 50 % du Mn forme des particules MnP et le restant est en etat paramagnetique au spin 5/2, dilue dans la matrice de l'InP. Finalement dans le dernier chapitre, 10, nous presentons les conclusions principales auxquels nous sommes arrives et discutons les resultats et leurs implications. Mots cles: implantation ionique, InP, GaP, amorphisation, MnP, segregation, co-implantation, couche polycristalline, paramagnetisme, ferromagnetisme.
NASA Astrophysics Data System (ADS)
Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min
2017-01-01
We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.
Optimal matching for prostate brachytherapy seed localization with dimension reduction.
Lee, Junghoon; Labat, Christian; Jain, Ameet K; Song, Danny Y; Burdette, Everette C; Fichtinger, Gabor; Prince, Jerry L
2009-01-01
In prostate brachytherapy, x-ray fluoroscopy has been used for intra-operative dosimetry to provide qualitative assessment of implant quality. More recent developments have made possible 3D localization of the implanted radioactive seeds. This is usually modeled as an assignment problem and solved by resolving the correspondence of seeds. It is, however, NP-hard, and the problem is even harder in practice due to the significant number of hidden seeds. In this paper, we propose an algorithm that can find an optimal solution from multiple projection images with hidden seeds. It solves an equivalent problem with reduced dimensional complexity, thus allowing us to find an optimal solution in polynomial time. Simulation results show the robustness of the algorithm. It was validated on 5 phantom and 18 patient datasets, successfully localizing the seeds with detection rate of > or = 97.6% and reconstruction error of < or = 1.2 mm. This is considered to be clinically excellent performance.
Gao, Qingqiang; Chen, Jianhuai; Dai, Yutian
2018-03-09
In the past 20 years, the incidence of prostate cancer has risen rapidly. It has been ranked as the third most common malignant tumor of the male genitourinary system. Testicular metastasis is uncommon in prostate cancer. Most cases are incidentally found in the treatment of prostate cancer with orchiectomy. Therefore, we believed it was necessary to report the case of our patient with this disease. We present a case of a 69-year-old Han Chinese man with a high total prostate-specific antigen level. A transrectal ultrasound-guided prostate biopsy was performed. A pathology report showed prostate cancer tissue with a Gleason score of 4 + 4 = 8/10. Imaging findings suggested that the prostate cancer tissue involved bilateral seminal vesicles and multiple bones. Next, radioactive seed implantation was carried out, and endocrine therapy was continued after the operation. Then enlargement of the left scrotum was found along with a total prostate-specific antigen level of 19.21 ng/ml. Computed tomography of the middle abdomen and pelvic cavity revealed 2.0 × 1.3-cm lesions of the left testis. The patient underwent a left testicular high resection and right orchiectomy. The postoperative pathology report showed metastatic prostate cancer cells in the left testis. Testicular metastasis of prostate cancer is rare. Therefore, a testicular physical examination is necessary for patients without relapse to avoid a missed diagnosis. Testicular metastasis should be treated according to the principle of treatment for advanced prostate adenocarcinoma if testicular metastasis of prostate adenocarcinoma is detected.
Prognostic Importance of Small Prostate Size in Men Receiving Definitive Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taira, Al V.; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org; Galbreath, Robert W.
Purpose: To assess whether small prostate size is an adverse prognostic factor in men undergoing brachytherapy in the same manner in which it seems to be for men undergoing radical prostatectomy. Methods and Materials: From April 1995 to June 2008, 2024 patients underwent brachytherapy by a single brachytherapist. Median follow-up was 7.4 years. The role of small prostate size ({<=}20 cm{sup 3}) as a prognostic factor for biochemical progression-free survival, cause-specific survival, and all-cause mortality was investigated. The differences in survival between men with small and larger prostates were compared using Kaplan-Meier curves and log-rank tests. Results: Median prostate sizemore » for the entire cohort was 32.7 cm{sup 3}. For the 167 men with small prostates, median prostate size was 17.4 cm{sup 3}. There was no difference in biochemical progression-free survival (95.2% vs 96.2%, P=.603), cause-specific survival (97.7% vs 98.3%, P=.546), or all-cause mortality (78.0% vs 77.2%, P=.838) at 10 years for men with small prostates compared with men with larger prostates. On univariate and multivariate analysis, small prostate size was not associated with any of the primary outcome measures. Conclusion: Men with small prostates treated with brachytherapy have excellent outcomes and are at no higher risk of treatment failure than men with larger glands. High-quality implants with adequate margins seem sufficient to address the increased adverse risk factors associated with small prostate size.« less
Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M
2017-02-01
BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Toye, Warren; Das, Ram; Kron, Tomas; Franich, Rick; Johnston, Peter; Duchesne, Gillian
2009-05-01
To develop an in vivo dosimetry based investigative action level relevant for a corrective protocol for HDR brachytherapy boost treatment. The dose delivered to points within the urethra and rectum was measured using TLD in vivo dosimetry in 56 patients. Comparisons between the urethral and rectal measurements and TPS calculations showed differences, which are related to the relative position of the implant and TLD trains, and allowed shifts of implant position relative to the prostate to be estimated. Analysis of rectal dose measurements is consistent with implant movement, which was previously only identified with the urethral data. Shift corrected doses were compared with results from the TPS. Comparison of peak doses to the urethra and rectum has been assessed against the proposed corrective protocol to limit overdosing these critical structures. An initial investigative level of 20% difference between measured and TPS peak dose was established, which corresponds to 1/3 of patients which was practical for the caseload. These patients were assessed resulting in corrective action being applied for one patient. Multiple triggering for selective investigative action is outlined. The use of a single in vivo measurement in the first fraction optimizes patient benefit at acceptable cost.
Quigley, Martin M; Mate, Timothy P; Sylvester, John E
2009-01-01
To evaluate the accuracy, utility, and cost effectiveness of a new electromagnetic patient positioning and continuous, real-time monitoring system, which uses permanently implanted resonant transponders in the target (Calypso 4D Localization System and Beacon transponders, Seattle, WA) to continuously monitor tumor location and movement during external beam radiation therapy of the prostate. This clinical trial studied 43 patients at 5 sites. All patients were implanted with 3 transponders each. In 41 patients, the system was used for initial alignment at each therapy session. Thirty-five patients had continuous monitoring during their radiation treatment. Over 1,000 alignment comparisons were made to a commercially available kV X-ray positioning system (BrainLAB ExacTrac, Munich, Germany). Using decision analysis and Markov processes, the outcomes of patients were simulated over a 5-year period and measured in terms of costs from a payer's perspective and quality-adjusted life years (QALYs). All patients had satisfactory transponder implantations for monitoring purposes. In over 75% of the treatment sessions, the correction to conventional positioning (laser and tattoos) directed by an electromagnetic patient positioning and monitoring system was greater than 5 mm. Ninety-seven percent (34/35) of the patients who underwent continuous monitoring had target motion that exceeded preset limits at some point during the course of their radiation therapy. Exceeding preset thresholds resulted in user intervention at least once during the therapy in 80% of the patients (28/35). Compared with localization using ultrasound, electronic portal imaging devices (EPID), or computed tomography (CT), localization with the electromagnetic patient positioning and monitoring system yielded superior gains in QALYs at comparable costs. Most patients positioned with conventional tattoos and lasers for prostate radiation therapy were found by use of the electromagnetic patient positioning and monitoring system to have alignment errors exceeding 5 mm. Almost all patients undergoing external beam radiation of the prostate have been shown to have target organ movement exceeding 3 mm during radiation therapy delivery. The ability of the electromagnetic technology to monitor tumor target location during the same time as radiation therapy is being delivered allows clinicians to provide real time adaptive radiation therapy for prostate cancer. This permits clinicians to intervene when the prostate moves outside the radiation isocenter, which should decrease adverse events and improve patient outcomes. Additionally, a cost-utility analysis has demonstrated that the electromagnetic patient positioning and monitoring system offers patient outcome benefits at a cost that falls well within the payer's customary willingness to pay (WTP) threshold of $50,000 per QALY.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, X; Chen, L; Hensley, H
2014-06-15
Purpose: Magnetic resonance spectroscopic (MRS) imaging may provide important bio-markers to distinguish normal/cancerous prostate tissue. While MRS imaging requires a high uniform magnetic field, the ability of a clinical 1.5T MRI to achieve a comparable MRS signal is of interest for radiation treatment planning/assessment. This study is to evaluate the MRS imaging of a 1.5T clinical MRI for prostate cancers by comparing with a small animal 7T MRS scanner. Methods: A tumor model was developed by implanting LNCaP tumor cells in nude mice prostates. Tumor was monitored 3 weeks after implantation using MRI, and MRS imaging was performed on themore » tumor area when the tumor reached around 1cm in diameter. The 1.5T GE clinical MR scanner and the 7T Bruker small animal MR scanner were used for each mouse. MR spectrums acquired with these scanners were analyzed and compared. The signals of Choline and Citrate were considered. Results: The prostate tumor MR spectrum under the 1.5T clinical MRI showed a similar spectrum pattern to that acquired using the 7T animal MRI. The Choline signal (3.2ppm) is clear and there is no clear peak for Citrate (2.6ppm). However, the signal magnitude for Choline is not dominant compared to the background signal under 1.5T MRI. Typical cancerous prostate tissue MR spectrum with an increased Choline signal and a reduced Citrate signal was observed. In addition, signal variation is noticeable between repeated spectrum scans. The average of these scans showed a comparable and consistent spectrum to those under 7T MRI. Conclusion: The clinical 1.5T MRI is able to acquire a MR spectrum for prostate cancer comparable to those acquired using a dedicated 7T MRS scanner. However, to achieve a consistent and reliable spectrum, multiple repeated scans were necessary to get a statistical result and reduce the noise-induced artifact. This work was supported in part by the National Cancer Institute Grant R21 CA131979 and R01CA172638.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank, Steven J., E-mail: sjfrank@mdanderson.org; Johansen, Mary J.; Martirosyan, Karen S.
2013-03-15
Purpose: C4, a cobalt dichloride-N-acetyl cysteine complex, is being developed as a positive-signal magnetic resonance imaging (MRI) marker to localize implanted radioactive seeds in prostate brachytherapy. We evaluated the toxicity and biodistribution of C4 in rats with the goal of simulating the systemic effects of potential leakage from C4 MRI markers within the prostate. Methods and Materials: 9-μL doses (equivalent to leakage from 120 markers in a human) of control solution (0.9% sodium chloride), 1% (proposed for clinical use), and 10% C4 solution were injected into the prostates of male Sprague-Dawley rats via laparotomy. Organ toxicity and cobalt disposition inmore » plasma, tissues, feces, and urine were evaluated. Results: No C4-related morbidity or mortality was observed in the biodistribution arm (60 rats). Biodistribution was measurable after 10% C4 injection: cobalt was cleared rapidly from periprostatic tissue; mean concentrations in prostate were 163 μg/g and 268 μg/g at 5 and 30 minutes but were undetectable by 60 minutes. Expected dual renal-hepatic elimination was observed, with percentages of injected dose recovered in tissues of 39.0 ± 5.6% (liver), >11.8 ± 6.5% (prostate), and >5.3 ± 0.9% (kidney), with low plasma concentrations detected up to 1 hour (1.40 μg/mL at 5-60 minutes). Excretion in urine was 13.1 ± 4.6%, with 3.1 ± 0.54% recovered in feces by 24 hours. In the toxicity arm, 3 animals died in the control group and 1 each in the 1% and 10% groups from surgical or anesthesia-related complications; all others survived to scheduled termination at 14 days. No C4-related adverse clinical signs or organ toxicity were observed. Conclusion: C4-related toxicity was not observed at exposures at least 10-fold the exposure proposed for use in humans. These data demonstrating lack of systemic toxicity with dual routes of elimination in the event of in situ rupture suggest that C4 warrants further investigation as an MRI marker for prostate brachytherapy.« less
Older, R A; Synder, B; Krupski, T L; Glembocki, D J; Gillenwater, J Y
2001-05-01
In several of the initial patients undergoing brachytherapy at our institution radioactive implants were visible in the thorax on chest radiography. The clinical ramifications of this unanticipated finding were unclear. Thus, we investigated the incidence of brachytherapy seed migration to the chest and whether these seeds were associated with any clinical significance. We retrospectively reviewed the records of all patients who underwent ultrasound or computerized tomography guided brachytherapy of 103palladium seeds from March 1997 to March 1999. This list of patients on brachytherapy was then matched against the radiology computer system to determine those who had undergone chest X-ray after brachytherapy. When the radiology report was unclear regarding brachytherapy seeds, chest x-rays were reviewed by one of us (R. O.) to determine the presence and position of the seeds. Post-brachytherapy chest x-rays were available in 110 of the 183 patients. In 78 cases no brachytherapy seeds were identified. Radioactive implants were identified on chest radiography in 32 patients (29%), including 1 to 5 seeds in 20, 8, 1, 2 and 1, respectively. No patients complained of any change in pulmonary symptoms after brachytherapy. Radioactive implants migrated after brachytherapy for localized prostate cancer in 29% of the patients who underwent post-procedure radiography. There did not appear to be a pattern to the seed distribution. However, while the incidence was not negligible, no patient appeared to have any acute pulmonary symptoms. Therefore, while the migration of radioactive implants to the chest is a real phenomenon, it appears to have no adverse clinical consequences in the early post-procedure period.
Whitmore, Henschke, and Hilaris: The reorientation of prostate brachytherapy (1970-1987).
Aronowitz, Jesse N
2012-01-01
Urologists had performed prostate brachytherapy for decades before New York's Memorial Hospital retropubic program. This paper explores the contribution of Willet Whitmore, Ulrich Henschke, Basil Hilaris, and Memorial's physicists to the evolution of the procedure. Literature review and interviews with program participants. More than 1000 retropubic implants were performed at Memorial between 1970 and 1987. Unlike previous efforts, Memorial's program benefited from the participation of three disciplines in its conception and execution. Memorial's retropubic program was a collaboration of urologists, radiation therapists, and physicists. Their approach focused greater attention on dosimetry and radiation safety, and served as a template for subsequent prostate brachytherapy programs. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chapman, Alexander T.; Rivens, Ian H.; Thompson, Alan C.; ter Haar, Gail R.
2007-05-01
HIFU may be an effective salvage treatment for patients who develop local recurrence after permanent low-dose brachytherapy. It has been suggested that the presence of seeds in the prostate may obstruct the HIFU beam or alter the heating characteristics of the prostate tissue. Acoustic field measurements were made using a membrane hydrophone and lesioning experiments were carried out in ex vivo bovine liver. These revealed a significant effect of the seeds on the HIFU focal region as well as a reduction in lesion length when seeds were placed in a pre-focal position. Further work is needed to evaluate the full effects of implanted brachytherapy seeds on the clinical delivery of HIFU.
BMP7 Induces Dormancy of Prostatic Tumor Stem Cell in Bone
2012-10-01
the upper back of nude mice. Recombinant human BMP7 was peritumorally injected daily after implantation. Tumor growth was monitored weekly by...of BMP7 was administrated daily through i.v. after intracardiac injection of CSCs from PC3mm or C4-2B cells to the mice. As shown in Figure 5A...mice, and then BMP7 was administrated daily . BLI of representative mice in each group six weeks after implantation (A). Normalized BLI signals
Interfraction Prostate Movement in Bone Alignment After Rectal Enema for Radiotherapy
Seo, Young Eun; Kim, Tae Hyo; Lee, Ki Soo; Cho, Won Yeol; Lee, Hyung-Sik; Hur, Won-Joo
2014-01-01
Purpose To assess the effect of a rectal enema on interfraction prostate movement in bone alignment (BA) for prostate radiotherapy (RT), we analyzed the spatial difference in prostates in a bone-matched setup. Materials and Methods We performed BA retrospectively with data from prostate cancer patients who underwent image-guided RT (IGRT). The prostate was identified with implanted fiducial markers. The setup for the IGRT was conducted with the matching of three fiducial markers on RT planning computed tomography images and those on two oblique kV x-ray images. Offline BA was performed at the same position. The coordinates of a virtual prostate in BA and a real prostate were obtained by use of the ExaxTrac/NovalisBody system, and the distance between them was calculated as the spatial difference. Interfraction prostate displacement was drawn from the comparison of the spatial differences. Results A total of 15 patients with localized prostate cancer treated with curative hypofractionated IGRT were enrolled. A total of 420 fractions were analyzed. The mean of the interfraction prostate displacements after BA was 3.12±2.00 mm (range, 0.20-10.53 mm). The directional difference was profound in the anterior-posterior and supero-inferior directions (2.14±1.73 mm and 1.97±1.44 mm, respectively) compared with the right-left direction (0.26±0.22 mm, p<0.05). The required margin around the clinical target volume was 4.97 mm with the formula of van Herk et al. Conclusions The interfraction prostate displacement was less frequent when a rectal enema was performed before the procedure. A rectal enema can be used to reduce interfraction prostate displacement and resulting clinical target volume-to-planning target volume margin. PMID:24466393
Null effect of dietary restriction on prostate carcinogenesis in the Wistar-Unilever rat.
McCormick, David L; Johnson, William D; Haryu, Todd M; Bosland, Maarten C; Lubet, Ronald A; Steele, Vernon E
2007-01-01
Chronic dietary restriction inhibits carcinogenesis in several sites in laboratory animals. To determine the effects of dietary restriction on prostate carcinogenesis, prostate cancers were induced in male Wistar-Unilever rats by a sequential regimen of cyproterone acetate (50 mg/day; 21 days); testosterone propionate (100 mg/kg/day; 3 days); N-methyl-N-nitrosourea [MNU; 30 mg/kg; single dose]; and testosterone (subcutaneous implants of 2 pellets containing 40 mg each). Dietary restriction (0% [ad libitum control], 15%, or 30%) was initiated 2 wk post-MNU, and continued until study termination at 12 mo. Dietary restriction induced a rapid suppression of body weight gain but conferred no protection against prostate carcinogenesis. 74% of carcinogen-treated ad libitum controls developed accessory sex gland cancers, versus cancer incidences of 64% and 72% in groups restricted by 15% and 30%, respectively. Similarly, 44% of dietary controls developed cancers limited to the dorsolateral/prostate, versus incidences of 45% and 53% in groups restricted by 15% and 30%. The results of the present study do not support the hypothesis that prostate carcinogenesis can be prevented by reducing caloric intake. Reducing mean body weight by up to 25% through chronic dietary restriction has no effect on the induction of prostate cancers in the Wistar-Unilever rat model.
Influence of the neural microenvironment on prostate cancer.
Coarfa, Christian; Florentin, Diego; Putluri, NagiReddy; Ding, Yi; Au, Jason; He, Dandan; Ragheb, Ahmed; Frolov, Anna; Michailidis, George; Lee, MinJae; Kadmon, Dov; Miles, Brian; Smith, Christopher; Ittmann, Michael; Rowley, David; Sreekumar, Arun; Creighton, Chad J; Ayala, Gustavo
2018-02-01
Nerves are key factors in prostate cancer (PCa), but the functional role of innervation in prostate cancer is poorly understood. PCa induced neurogenesis and perineural invasion (PNI), are associated with aggressive disease. We denervated rodent prostates chemically and physically, before orthotopically implanting cancer cells. We also performed a human neoadjuvant clinical trial using botulinum toxin type A (Botox) and saline in the same patient, before prostatectomy. Bilateral denervation resulted in reduced tumor incidence and size in mice. Botox treatment in humans resulted in increased apoptosis of cancer cells in the Botox treated side. A similar denervation gene array profile was identified in tumors arising in denervated rodent prostates, in spinal cord injury patients and in the Botox treated side of patients. Denervation induced exhibited a signature gene profile, indicating translation and bioenergetic shutdown. Nerves also regulate basic cellular functions of non-neoplastic epithelial cells. Nerves play a role in the homeostasis of normal epithelial tissues and are involved in prostate cancer tumor survival. This study confirms that interactions between human cancer and nerves are essential to disease progression. This work may make a major impact in general cancer treatment strategies, as nerve/cancer interactions are likely important in other cancers as well. Targeting the neural microenvironment may represent a therapeutic approach for the treatment of human prostate cancer. © 2017 The Authors. The Prostate Published by Wiley Periodicals, Inc.
Design and optimization of a brachytherapy robot
NASA Astrophysics Data System (ADS)
Meltsner, Michael A.
Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.
Ito, Kazuto; Saito, Shiro; Yorozu, Atsunori; Kojima, Shinsuke; Kikuchi, Takashi; Higashide, Satoshi; Aoki, Manabu; Koga, Hirofumi; Satoh, Takefumi; Ohashi, Toshio; Nakamura, Katsumasa; Katayama, Norihisa; Tanaka, Nobumichi; Nakano, Masahiro; Shigematsu, Naoyuki; Dokiya, Takushi; Fukushima, Masanori
2018-06-22
Investigating oncological outcomes in patients registered in the Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation (J-POPS) in terms of biochemical relapse-free survival (bRFS) by the Phoenix and the newly developed J-POPS definitions, exploration of predictive factors for bRFS, and preliminary verification of pitfalls of prostate-specific antigen (PSA) failure definitions. Between July 2005 and June 2007, 2316 clinically localized patients underwent permanent seed implantation. The primary endpoint was bRFS. One of the secondary endpoints was overall survival (OS). The median age was 69 and performance status was 0 in 99.1% of participants. The median biologically effective dose (BED) was about 180 Gy 2 . During a median follow-up of 60.0 months, 8.4 and 5.9% had PSA failure by the Phoenix and the J-POPS definitions, respectively. The 5-year bRFSs based on the Phoenix and the J-POPS definitions were 89.1 and 91.6%, respectively. The 5-year OS was 97.3%. According to multivariate analyses, only age affected bRFS based on the Phoenix definition, whereas the risk group and BED independently affected bRFS based on the J-POPS definition. A spontaneous PSA decrease was seen in 91.1% of participants after PSA failure based on the Phoenix definition alone, but in only 22.2% after PSA failure based on the J-POPS definition alone. The world's largest registration study, J-POPS, consisted of patients with longevity, and a highly quality-controlled BED resulted in excellent bRFS and OS. The high likelihood of PSA bounce by the Phoenix definition should be taken into account, especially in younger patients. NCT00534196.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neustadter, David; Barnea, Gideon; Stokar, Saul
Purpose: A fiducial tracking system based on a novel radioactive tracking technology is being developed for real-time target tracking in radiation therapy. In this study, the authors calculate the radiation dose to the patient, the spouse/caretaker, and the medical staff that would result from a 100 {mu}Ci Ir192 radioactive fiducial marker permanently implanted in the prostate of a radiation therapy patient. Methods: Local tissue dose was calculated by Monte Carlo simulation. The patient's whole body effective dose equivalent was calculated by summing the doses to the sensitive organs. Exposure of the spouse/caretaker was calculated from the NRC guidelines. Exposure ofmore » the medical staff was based on estimates of proximity to and time spent with the patient. Results: The local dose is below 40 Gy at 5 mm from the marker and below 10 Gy at 10 mm from the marker. The whole body effective dose equivalent to the patient is 64 mSv. The dose to the spouse/caretaker is 0.25 mSv. The annual exposures of the medical staff are 0.2 mSv for a doctor performing implantations and 0.34 mSv for a radiation therapist positioning patients for therapy. Conclusions: The local dose is not expected to have any clinically significant effect on the surrounding tissue which is irradiated during therapy. The dose to the patient is small in comparison to the whole body dose received from the therapy itself. The exposure of all other people is well below the recommended limits. The authors conclude that there is no radiation exposure related contraindication for use of this technology in the radiation treatment of prostate cancer.« less
Saal, Frederick S. vom; Timms, Barry G.; Montano, Monica M.; Palanza, Paola; Thayer, Kristina A.; Nagel, Susan C.; Dhar, Minati D.; Ganjam, V. K.; Parmigiani, Stefano; Welshons, Wade V.
1997-01-01
On the basis of results of studies using high doses of estrogens, exposure to estrogen during fetal life is known to inhibit prostate development. However, it is recognized in endocrinology that low concentrations of a hormone can stimulate a tissue, while high concentrations can have the opposite effect. We report here that a 50% increase in free-serum estradiol in male mouse fetuses (released by a maternal Silastic estradiol implant) induced a 40% increase in the number of developing prostatic glands during fetal life; subsequently, in adulthood, the number of prostatic androgen receptors per cell was permanently increased by 2-fold, and the prostate was enlarged by 30% (due to hyperplasia) relative to untreated males. However, as the free serum estradiol concentration in male fetuses was increased from 2- to 8-fold, adult prostate weight decreased relative to males exposed to the 50% increase in estradiol. As a model for fetal exposure to man-made estrogens, pregnant mice were fed diethylstilbestrol (DES) from gestation days 11 to 17. Relative to controls, DES doses of 0.02, 0.2, and 2.0 ng per g of body weight per day increased adult prostate weight, whereas a 200-ng-per-g dose decreased adult prostate weight in male offspring. Our findings suggest that a small increase in estrogen may modulate the action of androgen in regulating prostate differentiation, resulting in a permanent increase in prostatic androgen receptors and prostate size. For both estradiol and DES, prostate weight first increased then decreased with dose, resulting in an inverted-U dose-response relationship. PMID:9050904
Optical biopsy of the prostate: can we TRUST (trans-rectal ultrasound-coupled spectral tomography)?
NASA Astrophysics Data System (ADS)
Piao, Daqing; Jiang, Zhen; Bartels, Kenneth E.; Holyoak, G. Reed; Ritchey, Jerry W.; Rock, Kendra; Ownby, Charlotte L.; Bunting, Charles F.; Slobodov, Gennady
2011-03-01
Needle-based core-biopsy to locate prostate cancer relies heavily upon trans-rectal ultrasound (TRUS) imaging guidance. Ultrasonographic findings of classic hypoechoic peripheral zone lesions have a low specificity of ~28%, a low positive predictive value of ~29%, and an overall accuracy of ~43%, in prostate cancer diagnosis. The prevalence of isoechoic or nearly invisible prostate cancers on ultrasonography ranges from 25 to 42%. As a result, TRUS is useful and convenient to direct the needle trajectory following a systematic biopsy sampling template rather than to target only the potentially malignant lesion for focal-biopsy. To address this deficiency in the first-line of prostate cancer imaging, a trans-rectal ultrasound-coupled spectral tomography (TRUST) approach is being developed to non-invasively resolve the likely optical signatures of prostate malignancy. The approach has evolved from using one NIR wavelength to two NIR bands, and recently to three bands of NIR spectrum information. The concept has been evaluated on one normal canine prostate and three dogs with implanted prostate tumor developed as a model. The initial results implementing TRUST on the canine prostate tumor model includes: (1) quantifying substantially increased total hemoglobin concentration over the time-course of imaging in a rapidly growing prostate tumor; (2) confirming hypoxia in a prostatic cystic lesion; and (3) imaging hypoxic changes of a necrotic prostate tumor. Despite these interesting results, intensive technologic development is necessary for translating the approach to benefiting clinical practice, wherein the ultimate utility is not possibly to eliminate needle-biopsy but to perform focal-biopsy that is only necessary to confirm the cancer, as well as to monitor and predict treatment responses.
Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige
2017-08-01
To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p < 0.05). Interestingly, relative size of prostate apex in AP direction in sagittal image acquisitions compared to that in transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.
Hueso-González, Fernando; Ballester, Facundo; Perez-Calatayud, Jose; Siebert, Frank-André; Vijande, Javier
RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose-rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125 I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Dose-volume histogram-related parameters like prostate D 90 , rectum D 2cc , or urethra D 10 obtained with RayStretch agree within a few percent with the detailed MC results for all cases considered. The robustness and compatibility of RayStretch with commercial treatment planning systems indicate its applicability in clinical practice for dosimetric corrections in prostate calcifications. Its use during intraoperative ultrasound planning is foreseen. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Defining the rectal dose constraint for permanent radioactive seed implantation of the prostate.
Albert, Michele; Song, Jun S; Schultz, Delray; Cormack, Robert A; Tempany, Clare M; Haker, Steve; Devlin, Phillip M; Beard, Clair; Hurwitz, Mark D; Suh, Wonsuk W; Jolesz, Ferenc; D'Amico, Anthony V
2008-01-01
This study was performed to define the rectal dose constraint that would predict late rectal bleeding requiring argon plasma coagulation (APC) following prostate brachy mono-therapy. Between February 1999 and April 2002, 91 patients with low risk prostate cancer underwent permanent I(125) radioactive seed implantation without the use of supplemental external beam radiation or androgen suppression therapy. Patients received both CT and MRI scans 6 weeks postimplant for evaluation of dosimetry. The CT and MRI scans were fused. Rectal volumes were contoured on the T2 weighted MR images. For those patients requiring APC, the date on which a patient reported rectal bleeding was recorded. A Cox regression analysis was performed to assess whether there was a significant association between the rectal volume (continuous) exceeding 100 Gy time rectal bleeding. Comparisons of estimates of rectal bleeding requiring APC were made using a 2-sided log rank test. There was a significant association (hazard ratio = 5.6 [95% confidence interval: 1.3, 23.8]; P = 0.002) between the rectal volume exceeding 100 Gy and rectal bleeding requiring APC. After a median follow-up of 4.25 (1-6) years, no patient with less than a median value of 8 cc of rectum exceeding 100 Gy required APC, whereas 20% (P = 0.004) were estimated to require APC within 3 years following treatment. Keeping the rectal volume receiving more than 100 Gy below 8 cc will minimize the risk of rectal bleeding requiring APC following I(125) permanent prostate brachy mono-therapy.
Varma, Gopal; Clough, Rachel E; Acher, Peter; Sénégas, Julien; Dahnke, Hannes; Keevil, Stephen F; Schaeffter, Tobias
2011-05-01
In magnetic resonance imaging, implantable devices are usually visualized with a negative contrast. Recently, positive contrast techniques have been proposed, such as susceptibility gradient mapping (SGM). However, SGM reduces the spatial resolution making positive visualization of small structures difficult. Here, a development of SGM using the original resolution (SUMO) is presented. For this, a filter is applied in k-space and the signal amplitude is analyzed in the image domain to determine quantitatively the susceptibility gradient for each pixel. It is shown in simulations and experiments that SUMO results in a better visualization of small structures in comparison to SGM. SUMO is applied to patient datasets for visualization of stent and prostate brachytherapy seeds. In addition, SUMO also provides quantitative information about the number of prostate brachytherapy seeds. The method might be extended to application for visualization of other interventional devices, and, like SGM, it might also be used to visualize magnetically labelled cells. Copyright © 2010 Wiley-Liss, Inc.
Tsujimura, Akira; Fukuhara, Shinichiro; Soda, Tetsuji; Takezawa, Kentaro; Kiuchi, Hiroshi; Takao, Tetsuya; Miyagawa, Yasushi; Nonomura, Norio; Adachi, Shigeki; Tokita, Yoriko; Nomura, Taisei
2015-01-01
To evaluate histologic change in human prostate samples treated with dutasteride and to elucidate direct effects of dutasteride on human prostate tissue, the present study was conducted by using a xenograft model with improved severe combined immunodeficient (super-SCID) mice, although it is well known that dutasteride reduces prostate volume. After establishment of a xenograft model of human benign prostatic hyperplasia in morphology and function, samples implanted into super-SCID mice with and without dutasteride were evaluated pathohistologically at 2 and 6 months after initiation of dutasteride administration. The proliferative index evaluated by Ki-67 staining was significantly lower in the dutasteride group than the control at 2 and 6 months after administration. Apoptotic index evaluated by the terminal transferase TdT-mediated dUTP-biotin nick end labeling staining was higher in the dutasteride group than the control at 2 and 6 months after administration. Quick scores in the dutasteride group for staining of both cyclooxygenase-2 (Cox-2) and Ras homolog gene family, member A (RhoA) were significantly lower than those in the control group at 2 and 6 months after administration. Dutasteride inhibits cell proliferation and induces apoptosis of prostatic cells, causing a reduced prostate volume. Furthermore, decreased expression of Cox-2 and RhoA within benign prostatic hyperplasia tissue by dutasteride may induce an early effect on improvement of lower urinary tract symptoms, probably by attenuating inflammation reaction of the prostate and decreasing intraurethral pressure, other than the mechanism of reduced prostate volume. Copyright © 2015 Elsevier Inc. All rights reserved.
Low Testosterone Alters the Activity of Mouse Prostate Stem Cells.
Zhou, Ye; Copeland, Ben; Otto-Duessel, Maya; He, Miaoling; Markel, Susan; Synold, Tim W; Jones, Jeremy O
2017-04-01
Low serum testosterone (low T) has been repeatedly linked to worse outcomes in men with newly diagnosed prostate cancer (PC). How low T contributes to these outcomes is unknown. Here we demonstrate that exposure to low T causes significant changes in the mouse prostate and prostate stem cells. Mice were castrated and implanted with capsules to achieve castrate, normal, or sub-physiological levels of T. After 6 weeks of treatment, LC-MS/MS was used to quantify the levels of T and dihydrotestosterone (DHT) in serum and prostate tissue. FACS was used to quantify the percentages of purported prostate stem and transit amplifying (TA) cells in mouse prostates. Prostate tissues were also stained for the presence of CD68+ cells and RNA was extracted from prostate tissue or specific cell populations to measure changes in transcript levels with low T treatment. Despite having significantly different levels of T and DHT in the serum, T and DHT concentrations in prostate tissue from different T treatment groups were similar. Low T treatment resulted in significant alterations in the expression of androgen biosynthesis genes, which may be related to maintaining prostate androgen levels. Furthermore, the expression of androgen-regulated genes in the prostate was similar among all T treatment groups, demonstrating that the mouse prostate can maintain functional levels of androgens despite low serum T levels. Low T increased the frequency of prostate stem and TA cells in adult prostate tissue and caused major transcriptional changes in those cells. Gene ontology analysis suggested that low T caused inflammatory responses and immunofluorescent staining indicated that low T treatment led to the increased presence of CD68+ macrophages in prostate tissue. Low T alters the AR signaling axis which likely leads to maintenance of functional levels of prostate androgens. Low T also induces quantitative and qualitative changes in prostate stem cells which appear to lead to inflammatory macrophage infiltration. These changes are proposed to lead to an aggressive phenotype once cancers develop and may contribute to the poor outcomes in men with low T. Prostate 77:530-541, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
The evolution of brachytherapy for prostate cancer.
Zaorsky, Nicholas G; Davis, Brian J; Nguyen, Paul L; Showalter, Timothy N; Hoskin, Peter J; Yoshioka, Yasuo; Morton, Gerard C; Horwitz, Eric M
2017-06-30
Brachytherapy (BT), using low-dose-rate (LDR) permanent seed implantation or high-dose-rate (HDR) temporary source implantation, is an acceptable treatment option for select patients with prostate cancer of any risk group. The benefits of HDR-BT over LDR-BT include the ability to use the same source for other cancers, lower operator dependence, and - typically - fewer acute irritative symptoms. By contrast, the benefits of LDR-BT include more favourable scheduling logistics, lower initial capital equipment costs, no need for a shielded room, completion in a single implant, and more robust data from clinical trials. Prospective reports comparing HDR-BT and LDR-BT to each other or to other treatment options (such as external beam radiotherapy (EBRT) or surgery) suggest similar outcomes. The 5-year freedom from biochemical failure rates for patients with low-risk, intermediate-risk, and high-risk disease are >85%, 69-97%, and 63-80%, respectively. Brachytherapy with EBRT (versus brachytherapy alone) is an appropriate approach in select patients with intermediate-risk and high-risk disease. The 10-year rates of overall survival, distant metastasis, and cancer-specific mortality are >85%, <10%, and <5%, respectively. Grade 3-4 toxicities associated with HDR-BT and LDR-BT are rare, at <4% in most series, and quality of life is improved in patients who receive brachytherapy compared with those who undergo surgery.
Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang
2016-01-01
To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D90 of 34Gy in 8.5Gy per fraction, and 145Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2Gy per fraction, EQD2) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The Dmean (EQD2) of rectum decreased 22.36Gy in HDR and 17.01Gy in LDR from 30.24Gy in VMAT, respectively. The Dmean (EQD2) of bladder decreased 6.91Gy in HDR and 2.53Gy in LDR from 13.46Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD2) was 80.26, 70.23, and 104.91Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, X; Rahimian, J; Cosmatos, H
2014-06-01
Purpose: The goal of this research is to calculate and compare the Biological Equivalent Dose (BED) between permanent prostate Iodine-125 implant brachytherapy as monotherapy with the BED of conventional external beam radiation therapy (EBRT). Methods: A retrospective study of 605 patients treated with Iodine-125 seed implant was performed in which physician A treated 274 patients and physician B treated 331 patients. All the Brachytherapy treatment plans were created using VariSeed 8 planning system. The Iodine-125 seed source activities and loading patterns varied slightly between the two physicians. The prescription dose is 145 Gy to PTV for each patient. The BEDmore » and Tumor Control Probability (TCP) were calculated based on the TG 137 formulas. The BED for conventional EBRT of the prostate given in our institution in 2Gy per fraction for 38 fractions was calculated and compared. Results: Physician A treated 274 patients with an average BED of 123.92±0.87 Gy and an average TCP of 99.20%; Physician B treated 331 patients with an average BED of 124.87±1.12 Gy and an average TCP of 99.30%. There are no statistically significant differences (T-Test) between the BED and TCP values calculated for these two group patients.The BED of the patients undergoing conventional EBRT is calculated to be 126.92Gy. The BED of the patients treated with permanent implant brachytherapy and EBRT are comparable. Our BED and TCP values are higher than the reported values by TG 137 due to higher Iodine-125 seed activity used in our institution. Conclusion: We calculated the BED,a surrogate of the biological response to a permanent prostate brachytherapy using TG 137 formulas and recommendation. The TCP of better than 99% is calculated for these patients. A clinical outcome study of these patients correlating the BED and TCP values with PSA and Gleason Levels as well as patient survival is warranted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan
To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR andmore » LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.« less
Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor
2010-07-01
To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.
Arıkan Yorgun, Mücella; Mutlu, Melek; Toklu, Yasin; Cakmak, Hasan Basri; Cağıl, Nurullah
2014-06-01
A 58-year-old man admitted to our opthalmology department with the complaint of branch retinal vein occlusion. He was treated with intravitreal Ozurdex in the right eye. Two days after the injection, the patient presented with ocular pain and the visual acuity was hand movement. A diagnosis of endophthalmitis was made. We performed emergent pars plana vitrectomy (PPV) and the implant was removed from the vitreous cavity using a retinal forceps. A combination of vancomycin 1.0 mg and amikacin 0.4 mg was injected intravitreally. However, because of the blurring in the vitreus one week after the procedure, phacoemulsification and a repeat PPV was performed. Five days after the last procedure the signs and symptoms of endophthalmitis were resolved. Our case demonstrated that endophthalmitis could develop after intravitreal implantation of Ozurdex. Surgical removal of the implant and immediate vitrectomy seems to be a useful treatment option in these cases.
Alternative to radical surgery for cancer of the prostate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathes, G.L.; Page, R.C.
1978-08-01
We have used the technique of retropubic implantation of /sup 125/I seeds, as introduced by Whitmore and associates in 1972, in 12 selected patients with prostatic cancer. Morbidity has been minimal, and the tumor has been effectively controlled. This technique delivers more radiation and has fewer side effects than external cobalt irradiation, and it should be offered to the patient as an effective alternative to radical prostatectomy. It is best suited for patients with stage A, stage B, or small stage C lesions who have negative bone scans. Edema of the penis follows the lymphadenectomy but gradually subsides.
MacLean, Malcolm A; Scott, Bradley E; Deziel, Bob A; Nunnelley, Melissa C; Liberty, Anne M; Gottschall-Pass, Katherine T; Neto, Catherine C; Hurta, Robert A R
2011-01-01
Diets rich in fruits and vegetables have been shown to improve patient prognosis in a variety of cancers, a benefit partly derived from phytochemicals, many of which target cell death pathways in tumor cells. Cranberries (Vaccinium macrocarpon) are a phytochemical-rich fruit containing a variety of polyphenolic compounds. As flavonoids have been shown to induce apoptosis in human tumor cells, this study investigated the hypothesis that cranberry-mediated cytotoxicity in DU145 human prostate adenocarcinoma cells involves apoptosis. The results showed that induction of apoptosis in these cells occurred in response to treatment with whole cranberry extract and occurred through caspase-8 mediated cleavage of Bid protein to truncated Bid resulting in cytochrome-C release from the mitochondria. Subsequent activation of caspase-9 ultimately resulted in cell death as characterized by DNA fragmentation. Increased Par-4 protein expression was observed, and this is suggested to be at least partly responsible for caspase-8 activation. Proanthocyanidin-enriched and flavonol-enriched fractions of cranberry also increased caspase-8 and caspase-9 activity, suggesting that these compounds play a possible role in apoptosis induction. These findings indicate that cranberry phytochemicals can induce apoptosis in prostate cancer cells in vitro, and these findings further establish the potential value of cranberry phytochemicals as possible agents against prostate cancer.
Srivastava, Sanjay K; Xiao, Dong; Lew, Karen L; Hershberger, Pamela; Kokkinakis, Demetrius M; Johnson, Candace S; Trump, Donald L; Singh, Shivendra V
2003-10-01
We have shown previously that allyl isothiocyanate (AITC), a constituent of cruciferous vegetables, significantly inhibits survival of PC-3 and LNCaP human prostate cancer cells in culture, whereas proliferation of a normal prostate epithelial cell line is minimally affected by AITC even at concentrations that are highly cytotoxic to the prostate cancer cells. The present studies were designed to test the hypothesis that AITC administration may retard growth of human prostate cancer xenografts in vivo. Bolus i.p. injection of 10 micromol AITC, three times per week (Monday, Wednesday and Friday) beginning the day of tumor cell implantation, significantly inhibited the growth of PC-3 xenograft (P < 0.05 by two-way ANOVA). For example, 26 days after tumor cell implantation, the average tumor volume in control mice (1025 +/- 205 mm3) was approximately 1.7-fold higher compared with AITC-treated mice. Histological analysis of tumors excised at the termination of the experiment revealed a statistically significant increase in number of apoptotic bodies with a concomitant decrease in cells undergoing mitosis in the tumors of AITC-treated mice compared with that of control mice. Western blot analysis indicated an approximately 70% reduction in the levels of anti-apoptotic protein Bcl-2 in the tumor lysate of AITC-treated mice compared with that of control mice. Moreover, the tumors from AITC-treated mice, but not control mice, exhibited cleavage of BID, which is known to promote apoptosis. Statistically significant reduction in the expression of several proteins that regulate G2/M progression, including cyclin B1, cell division cycle (Cdc)25B and Cdc25C (44, 45 and 90% reduction, respectively, compared with control), was also observed in the tumors of AITC-treated mice relative to control tumors. In conclusion, the results of the present study indicate that AITC administration inhibits growth of PC-3 xenografts in vivo by inducing apoptosis and reducing mitotic activity.
Chao, Samuel T.; Angermeier, Kenneth; Klein, Eric A.; Reddy, Chandana A.; Ulchaker, James C.; Stephenson, Andrew; Campbell, Steven
2011-01-01
Purpose To study the feasibility/toxicity of urethral stenting with the Memokath® 028SW stent in patients undergoing prostate implant (PI) for prostate adenocarcinoma. Material and methods An Investigational Device Exemption from the Food and Drug Administration (FDA) and institutional review board (IRB) approval were obtained. Twenty patients enrolled. Baseline American Urological Association (AUA) score was obtained prior to PI. Follow-up information was obtained with weekly phone calls for the first 12 weeks and biweekly calls for the next 12 weeks to assess toxicity and AUA score. Removal of the stent was planned at six months after PI, or earlier due to excessive toxicity/patient request. Results Median age was 66.5 years. The median prostate volume was 39 cc (range: 10-90). The median baseline AUA score was 7.5 (range: 1-21). Three patients required intermittent self-catheterization (ISC) within 3 days after PI. No patients required ISC beyond day 3 after PI. The median duration of ISC was 1 day (range: 1-2). AUA scores returned to baseline values 6 weeks after PI. The week 6 AUA score was 10 (range: 4-16). Seven patients (35%) underwent early removal because of patient preference. The reasons were: incontinence (n = 3), discomfort (n = 2), hematuria (n = 1), and obstructive symptoms (n = 1). The median time of stent removal in these patients was 13.9 weeks (range: 0.9-21.4). Thirteen patients (65%) had ISC and/or urinary catheterization post stent removal. Median time for ISC use was 10 days (range: 1-90). Conclusions Urethral stenting with Memokath® in patients undergoing PI was feasible, but resulted in relatively high rate of urinary incontinence and discomfort. Given the adverse effects experienced by patients of this study, further studies should focus only on patients with highest risk of urinary obstruction from PI or those with obstruction needing ISC. PMID:27877196
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, Michael J.; Reddy, Chandana A.; Ulchaker, James
2009-04-01
Purpose: To determine whether the primary grade (PG) of biopsy Gleason score (GS) 7 prostate cancer (CaP) was predictive for biochemical relapse-free survival (bRFS). Most of the present data regarding the PG of GS7 CaP refer to surgical specimens. Our goal was to determine whether the biopsy GS used at the time of medical decision making predicted for the biochemical outcome. Methods and Materials: We reviewed the data from 705 patients with biopsy GS7 CaP, from a prospectively maintained database, who had been treated at our institution between September 1996 and March 2005 with radical prostatectomy (n = 310), externalmore » beam radiotherapy (n = 268), or prostate radioactive seed implantation (n = 127). The bRFS rates were estimated using the Kaplan-Meier method. Cox proportional hazards regression analysis was used for univariate and multivariate analyses examining these factors in relation to bRFS: PG of biopsy GS, initial prostate-specific antigen level, clinical T stage, use of androgen deprivation, risk group (high or intermediate), and treatment modality. Results: The 5-year bRFS rate was 78% and 71% (p = 0.0108) for biopsy GS7 PG3 CaP and biopsy GS7 PG4 CaP, respectively. Comparing PG3 and PG4 within treatment modalities, only prostate implantation patients had a significant difference in the 5-year bRFS rate, 88% vs. 76%, respectively (p = 0.0231). On multivariate analysis, the PG of biopsy GS remained an independent predictor of bRFS, with PG3 having better bRFS than PG4 (relative risk, 0.655; 95% confidence interval, 0.472-0.909; p = 0.0113). Conclusion: Biopsy GS7 PG4 CaP carries a worse bRFS than biopsy GS7 PG3 CaP.« less
Meani, Davide; Solarić, Mladen; Visapää, Harri; Rosén, Rose-Marie; Janknegt, Robert; Soče, Majana
2017-01-01
Background: Androgen deprivation therapy (ADT) with luteinizing hormone-releasing hormone (LHRH) agonists is well established for the treatment of men with metastatic prostate cancer. As clear differences in efficacy, safety, or tolerability between the available LHRH agonists are lacking, the healthcare management team needs to look to practical differences between the formulations when selecting therapy for their patients. Moreover, as the economic burden of prostate cancer rises alongside earlier diagnosis and improved survival, the possibility for cost savings by using products with specific features is growing in importance. Methods: A review was conducted to summarize the information on the different LHRH agonist formulations currently available and offer insight into their relative benefits and disadvantages from the perspectives of physicians, a pharmacist, and a nurse. Results: The leuprorelin acetate and goserelin acetate solid implants have the advantage of being ready to use with no requirement for refrigeration, whereas powder and microsphere formulations have to be reconstituted and have specific storage or handling constraints. The single-step administration of solid implants, therefore, has potential to reduce labor time and associated costs. Dosing frequency is another key consideration, as administering the injection provides an opportunity for face-to-face interaction between the patient and healthcare professionals to ensure therapy is optimized and give reassurance to patients. Prostate cancer patients are reported to prefer 3- or 6-monthly dosing, which aligns with the monitoring frequency recommended in European Association of Urology guidelines and has been shown to result in reduced annual costs compared with 1-month formulations. Conclusions: A number of practical differences exist between the different LHRH agonist preparations available, which may impact on clinical practice. It is important for healthcare providers to be aware and carefully consider these differences when selecting treatments for their prostate cancer patients. PMID:29434673
Castilla, Carolina; Flores, M Luz; Conde, José M; Medina, Rafael; Torrubia, Francisco J; Japón, Miguel A; Sáez, Carmen
2012-04-01
PTPL1, a non-receptor type protein tyrosine phosphatase, has been involved in the regulation of apoptosis and invasiveness of various tumour cell types, but its role in prostate cancer remained to be investigated. We report here that downregulation of PTPL1 by small interfering RNA in PC3 cells decreases cell proliferation and concomitantly reduces the expression of cell cycle-related proteins such as cyclins E and B1, PCNA, PTTG1 and phospho-histone H3. PTPL1 downregulation also increases the invasion ability of PC3 cells through Matrigel coated membranes. cDNA array of PTPL1-silenced PC3 cells versus control cells showed an upregulation of invasion-related genes such as uPA, uPAR, tPA, PAI-1, integrin α6 and osteopontin. This increased expression was also confirmed in PTPL1-silenced DU145 prostate cancer cells by quantitative real time PCR and western blot. These findings suggest that PTPL1 is an important mediator of central cellular processes such as proliferation and invasion.
High-Dose-Rate Brachytherapy as a Monotherapy for Favorable-Risk Prostate Cancer: A Phase II Trial
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barkati, Maroie; Williams, Scott G., E-mail: scott.williams@petermac.org; Department of Pathology, University of Melbourne, Melbourne
Purpose: There are multiple treatment options for favorable-risk prostate cancer. High-dose-rate (HDR) brachytherapy as a monotherapy is appealing, but its use is still investigational. A Phase II trial was undertaken to explore the value of such treatment in low-to-intermediate risk prostate cancer. Methods and Materials: This was a single-institution, prospective study. Eligible patients had low-risk prostate cancer features but also Gleason scores of 7 (51% of patients) and stage T2b to T2c cancer. Treatment with HDR brachytherapy with a single implant was administered over 2 days. One of four fractionation schedules was used in a dose escalation study design: 3more » fractions of 10, 10.5, 11, or 11.5 Gy. Patients were assessed with the Common Terminology Criteria for Adverse Events version 2.0 for urinary toxicity, the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring schema for rectal toxicity, and the Expanded Prostate Cancer Index Composite (EPIC) questionnaire to measure patient-reported health-related quality of life. Biochemical failure was defined as a prostate-specific antigen (PSA) nadir plus 2 ng/ml. Results: Between 2003 and 2008, 79 patients were enrolled. With a median follow-up of 39.5 months, biochemical relapse occurred in 7 patients. Three- and 5-year actuarial biochemical control rates were 88.4% (95% confidence interval [CI], 78.0-96.2%) and 85.1% (95% CI, 72.5-94.5%), respectively. Acute grade 3 urinary toxicity was seen in only 1 patient. There was no instance of acute grade 3 rectal toxicity. Rates of late grade 3 rectal toxicity, dysuria, hematuria, urinary retention, and urinary incontinence were 0%, 10.3%, 1.3%, 9.0%, and 0%, respectively. No grade 4 or greater toxicity was recorded. Among the four (urinary, bowel, sexual, and hormonal) domains assessed with the EPIC questionnaire, only the sexual domain did not recover with time. Conclusions: HDR brachytherapy as a monotherapy for favorable-risk prostate cancer, administered using a single implant over 2 days, is feasible and has acceptable acute and late toxicities. Further follow-up is still required to better evaluate the efficacy of such treatment.« less
de Bessa Garcia, Simone A; Pereira, Michelly C; Nagai, Maria A
2010-12-21
The histological organization of the mammary gland involves a spatial interaction of epithelial and myoepithelial cells with the specialized basement membrane (BM), composed of extra-cellular matrix (ECM) proteins, which is disrupted during the tumorigenic process. The interactions between mammary epithelial cells and ECM components play a major role in mammary gland branching morphogenesis. Critical signals for mammary epithelial cell proliferation, differentiation, and survival are provided by the ECM proteins. Three-dimensional (3D) cell culture was developed to establish a system that simulates several features of the breast epithelium in vivo; 3D cell culture of the spontaneously immortalized cell line, MCF10A, is a well-established model system to study breast epithelial cell biology and morphogenesis. Mammary epithelial cells grown in 3D form spheroids, acquire apicobasal polarization, and form lumens that resemble acini structures, processes that involve cell death. Using this system, we evaluated the expression of the pro-apoptotic gene PAWR (PKC apoptosis WT1 regulator; also named PAR-4, prostate apoptosis response-4) by immunofluorescence and quantitative real time PCR (qPCR). A time-dependent increase in PAR-4 mRNA expression was found during the process of MCF10A acinar morphogenesis. Confocal microscopy analysis also showed that PAR-4 protein was highly expressed in the MCF10A cells inside the acini structure. During the morphogenesis of MCF10A cells in 3D cell culture, the cells within the lumen showed caspase-3 activation, indicating apoptotic activity. PAR-4 was only partially co-expressed with activated caspase-3 on these cells. Our results provide evidence, for the first time, that PAR-4 is differentially expressed during the process of MCF10A acinar morphogenesis.
Sun, Jin Kim; Uehara, Hisanori; Karashima, Takashi; Mccarty, Marya; Shih, Nancy; Fidler, Isaiah J
2001-01-01
Abstract We determined whether the expression of interleukin-8 (IL-8) by human prostate cancer cells correlates with induction of angiogenesis, tumorigenicity, and production of metastasis. Low and high IL-8-producing clones were isolated from the heterogeneous PC-3 human prostate cancer cell line. The secretion of IL-8 protein correlated with transcriptional activity and levels of IL-8 mRNA. All PC-3 cells expressed both IL-8 receptors, CXCR1 and CXCR2. The low and high IL-8-producing clones were injected into the prostate of nude mice. Titration studies indicated that PC-3 cells expressing high levels of IL-8 were highly tumorigenic, producing rapidly growing, highly vascularized prostate tumors with and a 100% incidence of lymph node metastasis. Low IL-8-expressing PC-3 cells were less tumorigenic, producing slower growing and less vascularized primary tumors and a significantly lower incidence of metastasis. In situ hybridization (ISH) analysis of the tumors for expression of genes that regulate angiogenesis and metastasis showed that the expression level of IL-8, matrix metalloproteinases, vascular endothelial growth factor (VEGF), and E-cadherin corresponded with microvascular density and biological behavior of the prostate cancers in nude mice. Collectively, the data show that the expression level of IL-8 in human prostate cancer cells is associated with angiogenesis, tumorigenicity, and metastasis. PMID:11326314
Influence of the neural microenvironment on prostate cancer
Coarfa, Christian; Florentin, Diego; Putluri, NagiReddy; Ding, Yi; Au, Jason; He, Dandan; Ragheb, Ahmed; Frolov, Anna; Michailidis, George; Lee, MinJae; Kadmon, Dov; Miles, Brian; Smith, Christopher; Ittmann, Michael; Rowley, David; Sreekumar, Arun; Creighton, Chad J.
2017-01-01
Background Nerves are key factors in prostate cancer (PCa), but the functional role of innervation in prostate cancer is poorly understood. PCa induced neurogenesis and perineural invasion (PNI), are associated with aggressive disease. Method We denervated rodent prostates chemically and physically, before orthotopically implanting cancer cells. We also performed a human neoadjuvant clinical trial using botulinum toxin type A (Botox) and saline in the same patient, before prostatectomy. Result Bilateral denervation resulted in reduced tumor incidence and size in mice. Botox treatment in humans resulted in increased apoptosis of cancer cells in the Botox treated side. A similar denervation gene array profile was identified in tumors arising in denervated rodent prostates, in spinal cord injury patients and in the Botox treated side of patients. Denervation induced exhibited a signature gene profile, indicating translation and bioenergetic shutdown. Nerves also regulate basic cellular functions of non‐neoplastic epithelial cells. Conclusion Nerves play a role in the homeostasis of normal epithelial tissues and are involved in prostate cancer tumor survival. This study confirms that interactions between human cancer and nerves are essential to disease progression. This work may make a major impact in general cancer treatment strategies, as nerve/cancer interactions are likely important in other cancers as well. Targeting the neural microenvironment may represent a therapeutic approach for the treatment of human prostate cancer. PMID:29131367
Null Activity of Selenium and Vitamin E as Cancer Chemopreventive Agents in the Rat Prostate1
McCormick, David L.; Rao, K.V.N.; Johnson, William D.; Bosland, Maarten C.; Lubet, Ronald A.; Steele, Vernon E.
2009-01-01
To evaluate the potential efficacy of selenium and vitamin E as inhibitors of prostate carcinogenesis, four chemoprevention studies using a common protocol were performed in a rat model of androgen-dependent prostate cancer. After stimulation of prostate epithelial cell proliferation by a sequential regimen of cyproterone acetate followed by testosterone propionate, male Wistar-Unilever rats received a single intravenous injection of N-methyl-N-nitrosourea (MNU) followed by chronic androgen stimulation via subcutaneous implantation of testosterone pellets. At one week post-MNU, groups of carcinogen-treated rats (39–44/group) were fed either basal diet or basal diet supplemented with L-selenomethionine (3 or 1.5 mg/kg diet; Study 1); DL-α-tocopherol (Vitamin E; 4000 or 2000 mg/kg diet; Study 2); L-selenomethionine + Vitamin E (3 + 2000 mg/kg diet or 3 + 500 mg/kg diet; Study 3), or selenized yeast (target selenium levels of 9 or 3 mg/kg diet; Study 4). Each chemoprevention study was terminated at 13 months post-MNU, and prostate cancer incidence was determined by histopathologic evaluation. No statistically significant reductions in prostate cancer incidence were identified in any group receiving dietary supplementation with selenium and/or vitamin E. These data do not support the hypotheses that selenium and vitamin E are potent cancer chemopreventive agents in the prostate, and when considered with the recent clinical data reported in the SELECT trial, demonstrate the predictive nature of this animal model for human prostate cancer chemoprevention. PMID:20145190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, Paul L., E-mail: E-pnguyen@LROC.harvard.ed; Harvard Medical School, Boston, MA; Chen, Ming H.
Background: Brachytherapy for prostate cancer can be technically challenging in men with small prostates ({<=}20 cc), but it is unknown whether their outcomes are different than those of men with larger prostates. Methods and Materials: We studied 6,416 men treated with brachytherapy in one of 21 community-based practices. Cox regression and Fine and Gray's regression were used to determine whether volume {<=}20 cc was associated with a higher risk of all-cause mortality (ACM) or prostate cancer-specific mortality (PCSM), respectively, after adjustment for other known prognostic factors. Results: 443 patients (6.9%) had a prostate volume {<=}20 cc. After a median follow-upmore » of 2.91 years (interquartile range, 1.06-4.79), volume {<=}20 cc was associated with a significantly higher risk of ACM (adjusted hazard ratio = 1.33 [95% CI 1.08-1.65], p = 0.0085) with 3-year estimates of ACM for {<=}20 cc vs. >20 cc of 13.0% vs. 6.9% (p = 0.028). Only 23 men (0.36%) have died of prostate cancer, and no difference was seen in PCSM by volume (p = 0.4). Conclusion: Men with small prostates at the time of implant had a 33% higher risk of ACM, and the underlying cause of this remains uncertain. No increase in PCSM was observed in men with volume {<=}20cc, suggesting that a small prostate should not in itself be a contraindication for brachytherapy, but inasmuch as absolute rates of PCSM were small, further follow-up will be needed to confirm this finding.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, Charles C., E-mail: hsucc@radonc.ucsf.edu; Hsu, Howard; Pickett, Barby
Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutivemore » rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or {>=}7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound-guided biopsy results). Phoenix PFS rates at 1, 2, and 3 years were 100%, 100%, and 71.4%. 73%, respectively; achieved PSA nadir of <0.5 ng/mL; and 47% of patients had a nadir of <0.1 ng/mL. Treatment-related toxicity was minimal, with no operative interventions, fistulas, or other grade {>=}3 gastrointestinal (GI)/genitourinary (GU) toxicity. Thirteen percent had grade 1 GI and 33% had grade 2 GU toxicities. Postsalvage, 20% of patients had no erectile dysfunction, 67% of patients had medication-responsive erectile dysfunction, and 13% of patients had erectile dysfunction refractory to medication. Conclusions: Focal psPPI with MR-planning in highly selected patients is feasible with short-term control comparable to conventional salvage, with less toxicity. Longer follow-up is needed to confirm its impact on quality of life and treatment.« less
Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan
2014-01-01
AIM To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. METHODS Non-comparative retrospective observational case series. Participants: 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures: visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. RESULTS The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. CONCLUSION To take early treatment of traumatic lens subluxation/dislocation in patients with secondary glaucoma by individual surgical plan based on the different eye conditions would be safe and effective, which can effectively control the intraocular pressure and restore some vision. PMID:24790868
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, A.; Edmundson, G.K.; Cox, R.S.
1985-02-01
The authors have devised a single after-loading applicator, the Martinez Universal Perineal Interstitital Template (MUPIT), which has been used in combination with external beam irradiation to treat 104 patients with either locally advanced or recurrent malignancies of the cervix, vagina, female uretha, prostate, or anorectal region. Twenty-six patients treated for prostate cancer are excluded because of their short follow-up. Local failure developed in 13 of the 78 remaining patients (16.6%) - major complications developed in 4 patients (5.1%). All local recurrences and complications occurred before 18 months. The device consists of two acrylic cyclinders, an acrylic template with an arraymore » of holes that serve as guides for trocars, and a cover plate. In use, the cylinders are placed in the vagina and/or rectum or both and then fastened to the template so that a fixed geometric relationship among the tumor volume, normal structures, and source placement is preserved throughout the course of the implantation. Appropriate computer programs have been developed to calculate the dose from these implants. They conclude that the local control rate (83.4%) with low morbidity (5.1%) achieved with the combination of external beam irradiation and MUPIT applicator in these patients with locally advanced malignancies represents an improvement over previous published results with other applicators.« less
Brisseau, Lionel; Bussières, Jean-François; Lebel, Denis; Atkinson, Suzanne; Robinette, Louise; Fortin, Sylvie; Lemay, Michel
2011-01-01
RÉSUMÉ Contexte : Il existe peu de données sur les conséquences de l’utilisation des cabinets automatisés décentralisés (CAD) en établissements de santé. Méthode : Il s’agit d’une étude descriptive de la conformité des pratiques par rapport à des lignes directrices publiées dans le cadre de l’implantation de CAD. L’objectif principal de l’étude est d’évaluer la conformité globale et celle de chaque processus du circuit du médicament. L’étude se déroule au sein du Centre hospitalier universitaire (CHU) Sainte-Justine, un établissement mère–enfant de 500 lits. À partir des lignes directrices portant sur l’utilisation sécuritaire des CAD de l’Institute for Safe Medication Practice (aux États-Unis) (2008) et de son outil d’autoévaluation (2009), nous avons évalué la conformité de la pratique à 30 jours et à 120 jours après l’implantation. Résultats : Nous avons procédé de novembre 2009 à avril 2010 à l’implantation de sept stations de CAD au sein du CHU Sainte-Justine. Le profil de conformité est passé de 66 % à 74 % de janvier à avril 2010. Pour chaque processus relatif à l’utilisation sécuritaire des CAD, nous présentons une brève description des critères ainsi que les éléments de non-conformité liés à la technologie ou aux aspects organisationnels. Pour chaque élément de non-conformité, nous avons déterminé les actions requises auprès du fabricant afin de modifier l’équipement (c. à .d. aspects technologiques) et auprès de l’établissement afin de modifier les modalités d’utilisation (aspects organisationnels) en précisant le ou les processus impliqués. Conclusion : Cette étude décrit la conformité des pratiques au CHU Sainte-Justine par rapport à des lignes directrices publiées par l’Institute for Safe Medication Practices. L’utilisation de lignes directrices dans le cadre de l’implantation de cabinets automatisés décentralisés en établissement peut aider à guider les actions tant sur le plan technologique qu’organisationnel. PMID:22479039
Inhibition of rat prostate tumor growth by an octapeptide analog of somatostatin.
Murphy, W A; Lance, V A; Moreau, S; Moreau, J P; Coy, D H
1987-06-29
Analogs of a potent octapeptide analog of somatostatin (SRIF) H-(D)Phe-Cys-Tyr-(D)Trp-Lys-Val-Cys-Thr(NH2) were synthesized. Aromatic substitutions for Tyr resulted in little change in inhibitory potency on growth hormone (GH) secretion in the rat. Substitutions for Val or (D)Trp resulted in analogs with diminished activity. Substitution of (D)Nal for (D)Phe increased duration of GH inhibition. Final weights of subcutaneously implanted prostate tumors (R3327) were 41% lower in rats treated with an N-terminal 4-chloro-(D)phenylalanyl analog as compared to vehicle treated controls. The analog had no effect on testicular weight or final plasma testosterone levels. SRIF analogs may represent an alternative treatment for prostate cancer that would be free of the untoward reproductive effects of other treatments (e.g. LH-RH or castration).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roeloffzen, Ellen M., E-mail: e.m.a.roeloffzen@umcutrecht.nl; Vulpen, Marco van; Battermann, Jan J.
Purpose: Acute urinary retention (AUR) after iodine-125 (I-125) prostate brachytherapy negatively influences long-term quality of life and therefore should be prevented. We aimed to develop a nomogram to preoperatively predict the risk of AUR. Methods: Using the preoperative data of 714 consecutive patients who underwent I-125 prostate brachytherapy between 2005 and 2008 at our department, we modeled the probability of AUR. Multivariate logistic regression analysis was used to assess the predictive ability of a set of pretreatment predictors and the additional value of a new risk factor (the extent of prostate protrusion into the bladder). The performance of the finalmore » model was assessed with calibration and discrimination measures. Results: Of the 714 patients, 57 patients (8.0%) developed AUR after implantation. Multivariate analysis showed that the combination of prostate volume, IPSS score, neoadjuvant hormonal treatment and the extent of prostate protrusion contribute to the prediction of AUR. The discriminative value (receiver operator characteristic area, ROC) of the basic model (including prostate volume, International Prostate Symptom Score, and neoadjuvant hormonal treatment) to predict the development of AUR was 0.70. The addition of prostate protrusion significantly increased the discriminative power of the model (ROC 0.82). Calibration of this final model was good. The nomogram showed that among patients with a low sum score (<18 points), the risk of AUR was only 0%-5%. However, in patients with a high sum score (>35 points), the risk of AUR was more than 20%. Conclusion: This nomogram is a useful tool for physicians to predict the risk of AUR after I-125 prostate brachytherapy. The nomogram can aid in individualized treatment decision-making and patient counseling.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marcu, Loredana G., E-mail: loredana@marcunet.com; Faculty of Science, University of Oradea; School of Chemistry and Physics, University of Adelaide, South Australia
2013-10-01
Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methodsmore » was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.« less
Neal, Robert E; Smith, Ryan L; Kavnoudias, Helen; Rosenfeldt, Franklin; Ou, Ruchong; Mclean, Catriona A; Davalos, Rafael V; Thomson, Kenneth R
2013-12-01
Electroporation-based therapies deliver brief electric pulses into a targeted volume to destabilize cellular membranes. Nonthermal irreversible electroporation (IRE) provides focal ablation with effects dependent on the electric field distribution, which changes in heterogeneous environments. It should be determined if highly conductive metallic implants in targeted regions, such as radiotherapy brachytherapy seeds in prostate tissue, will alter treatment outcomes. Theoretical and experimental models determine the impact of prostate brachytherapy seeds on IRE treatments. This study delivered IRE pulses in nonanimal, as well as in ex vivo and in vivo tissue, with and in the absence of expired radiotherapy seeds. Electrical current was measured and lesion dimensions were examined macroscopically and with magnetic resonance imaging. Finite-element treatment simulations predicted the effects of brachytherapy seeds in the targeted region on electrical current, electric field, and temperature distributions. There was no significant difference in electrical behavior in tissue containing a grid of expired radiotherapy seeds relative to those without seeds for nonanimal, ex vivo, and in vivo experiments (all p > 0.1). Numerical simulations predict no significant alteration of electric field or thermal effects (all p > 0.1). Histology showed cellular necrosis in the region near the electrodes and seeds within the ablation region; however, there were no seeds beyond the ablation margins. This study suggests that electroporation therapies can be implemented in regions containing small metallic implants without significant changes to electrical and thermal effects relative to use in tissue without the implants. This supports the ability to use IRE as a salvage therapy option for brachytherapy.
Zheng, Cindy X; Moster, Marlene R; Khan, M Ali; Chiang, Allen; Garg, Sunir J; Dai, Yang; Waisbourd, Michael
2017-06-01
To report the clinical features, microbial spectrum, and treatment outcomes of endophthalmitis after glaucoma drainage implant (GDI) surgery. Records of patients diagnosed with endophthalmitis after GDI surgery were reviewed. Data on clinical course, microbiological laboratory results, and treatment were analyzed. Of 1,891 eyes that underwent GDI surgery, 14 eyes (0.7%) developed endophthalmitis. The mean time interval between GDI surgery and diagnosis of endophthalmitis was 2.6 ± 3.2 years (median, 1.3 years; range, 11 days-11.4 years). For initial treatment, 13/14 eyes underwent vitreous tap and injection of intravitreal antibiotics and 1/14 eyes underwent primary pars plana vitrectomy. Three additional eyes underwent pars plana vitrectomy because of deteriorating clinical course. Glaucoma drainage implant erosion was present in 9/14 eyes. All 9 eroded GDIs were surgically removed within a mean of 9 ± 5 days (range 2-29 days) after diagnosis of endophthalmitis. Overall, mean logarithm of the minimum angle of resolution best-corrected visual acuity worsened from 0.7 ± 0.7 (Snellen equivalent 20/100) at baseline to 1.6 ± 1.1 (Snellen equivalent 20/800) at final follow-up (P = 0.005). Mean duration between the onset of symptoms and presentation was significantly longer in patients with decreased final best-corrected visual acuity (>2 Snellen lines) compared to patients with stable final best-corrected visual acuity (6.8 vs. 1.0 days; P = 0.005). Glaucoma drainage implant-related endophthalmitis is rare and often associated with GDI erosion. Patients who presented earlier after the onset of symptoms had better final visual outcomes. Prompt evaluation and treatment is required, often with removal of the eroded GDI.
Schwarzenböck, Sarah Marie; Gertz, Jana; Souvatzoglou, Michael; Kurth, Jens; Sachs, David; Nawroth, Roman; Treiber, Uwe; Schuster, Tibor; Senekowitsch-Schmidtke, Reingard; Schwaiger, Markus; Ziegler, Sibylle Ilse; Henriksen, Gjermund; Wester, Hans-Jürgen; Krause, Bernd Joachim
2015-04-01
Carbon-11- and fluorine-18-labeled choline derivatives have been introduced as promising tracers for prostate cancer imaging. However, due to limited specificity and sensitivity, there is a need for new tracers with higher sensitivity and specificity for diagnosing prostate cancer to improve tracer uptake and enhance imaging contrast. The aim of this study was to compare the properties of [(11)C]choline ([(11)C]CHO) with S(+)-β-methyl-[(11)C]choline ([(11)C]SMC) as tracer for prostate cancer imaging in a human prostate tumor mouse xenograft model by small-animal positron emission tomography/X-ray computed tomography (PET/CT). We carried out a dual-tracer small-animal PET/CT study comparing [(11)C]CHO and [(11)C]SMC. The androgen-independent human prostate tumor cell line PC3 was implanted subcutaneously in the flanks of Naval Medical Research Institute (NMRI) (nu/nu) mice (n = 11). Mice-6 weeks post-xenograft implantation-were injected with 37 MBq [(11)C]CHO via the tail vein. On a separate day, the mice were injected with 37 MBq [(11)C]SMC. Dynamic imaging was performed for 60 min with the Inveon animal PET/CT scanner (Siemens Medical Solutions) on two separate days (randomizing the sequence of the tracers). The dynamic PET images were acquired in list mode. Regions of interest (5 × 5 × 5 mm) were placed in transaxial slices in tumor, muscle (thigh), liver, kidney, and blood. Image analysis was performed calculating tumor to muscle (T/M) ratios based on summed images as well as dynamic data. For [(11)C]SMC, the mean T/M ratio was 2.24 ± 0.56 while the corresponding mean [(11)C]CHO T/M ratio was 1.35 ± 0.28. The T/M ratio for [(11)C]SMC was significant higher compared to [(11)C]CHO (p < 0.001). The time course of T/M ratio (T/Mdyn ratio) of [(11)C]SMC was higher compared to [(11)C]CHO with a statistically significant difference between the magnitudes of the T/M ratios and a significant different change of the T/M ratios over time between [(11)C]CHO and [(11)C]SMC. Our results demonstrate that [(11)C]SMC is taken up by the tumor in the PC-3 prostate cancer xenograft model. [(11)C]SMC uptake was significantly higher compared to the clinically utilized [(11)C]CHO tracer with a higher contrast allowing imaging of a prostate cancer xenograft.
Dostalova, Simona; Polanska, Hana; Svobodova, Marketa; Balvan, Jan; Krystofova, Olga; Haddad, Yazan; Krizkova, Sona; Masarik, Michal; Eckschlager, Tomas; Stiborova, Marie; Heger, Zbynek; Adam, Vojtech
2018-06-11
Herein, we describe the in vivo effects of doxorubicin (DOX) encapsulated in ubiquitous protein apoferritin (APO) and its efficiency and safety in anti-tumor treatment. APODOX is both passively (through Enhanced Permeability and Retention effect) and actively targeted to tumors through prostate-specific membrane antigen (PSMA) via mouse antibodies conjugated to the surface of horse spleen APO. To achieve site-directed conjugation of the antibodies, a HWRGWVC heptapeptide linker was used. The prostate cancer-targeted and non-targeted nanocarriers were tested using subcutaneously implanted LNCaP cells in athymic mice models, and compared to free DOX. Prostate cancer-targeted APODOX retained the high potency of DOX in attenuation of tumors (with 55% decrease in tumor volume after 3 weeks of treatment). DOX and non-targeted APODOX treatment caused damage to liver, kidney and heart tissues. In contrast, no elevation in liver or kidney enzymes and negligible changes were revealed by histological assessment in prostate cancer-targeted APODOX-treated mice. Overall, we show that the APO nanocarrier provides an easy encapsulation protocol, reliable targeting, high therapeutic efficiency and very low off-target toxicity, and is thus a promising delivery system for translation into clinical use.
A Mechanistic Study of Proapoptotic Daxx-Par4 Axis in Prostate Cancer
2011-01-01
markers of autophagy: Beclin-1, LC3 , and p62 . In culture, Daxx K/D cells also exhibited increased basal and inducible (rapamycin; nutrient...deprivation) autophagy. We observed changes in autophagy markers in Daxx K/D cells in culture, including an increase in the LC3 -II:LC3-I ratio, decreased p62 ...tumors exhibited elevated levels of DAPK1 protein, and also an increase in the autophagy markers Beclin-1 and LC3 , as determined via IHC (Fig. 1B). In
Impact of maternal and postnatal zinc dietary status on the prostate of pubescent and adult rats.
Camora, Lucas F; Silva, Ana Priscila G; Santos, Sérgio A A; Justulin, Luis A; Perobelli, Juliana E; Barbisan, Luis Fernando; Scarano, Wellerson R
2017-11-01
Zinc is important for cell physiology and alteration of its levels during development can modulate a series of biological events. The aim of this study was to investigate whether dietary zinc deficiency or supplementation during morphogenesis and early postnatal development could interfere in prostate maturation. Pregnant rats were exposed to a standard diet (NZ:35 mg Zn/kg chow), low-zinc diet (LZ:3 mg of Zn/kg chow) and zinc-supplemented diet (HZ:180 mg/Kg chow) from gestational day 10 (GD10) through postnatal day 21 (PND21). After weaning, male offspring were divided into three groups that were submitted to the same food conditions as their mothers until PND53. The animals were euthanized at PND53 and PND115. The ventral prostate was removed, weighed and its fragments were subjected to histological, western blot and zymography analysis. PND53: body and prostate weight were lower in LZ compared to NZ; the epithelial compartment was reduced while the stromal compartment was increased in LZ compared to NZ; there was an increase in the amount of collagen and reduction in AR and SIRT1 expression in LZ compared to NZ. PND115: body weight was lower in LZ compared to NZ and prostate weight was similar among the groups; peripheral physiological hyperplasia was observed, as well as an increased epithelial proliferation index and reduced PAR4 expression in LZ and HZ compared to NZ. Zinc deficiency during prostate morphogenesis and differentiation is potentially harmful to its morphology, however, by restoring the standard dietary environment, the gland responds to the new microenvironment independent of the previous dietary condition. © 2017 International Federation for Cell Biology.
Ghotbaddini, Maryam; Cisse, Keyana; Carey, Alexis; Powell, Joann B
2017-01-01
Altered c-Src activity has been strongly implicated in the development, growth, progression, and metastasis of human cancers including prostate cancer. Src is known to regulate several biological functions of tumor cells, including proliferation. There are several Src inhibitors under evaluation for clinical effectiveness but have shown little activity in monotherapy trials of solid tumors. Combination studies are being explored by in vitro analysis and in clinical trials. Here we investigate the effect of simultaneous inhibition of the aryl hydrocarbon receptor (AhR) and Src on androgen receptor (AR) signaling in prostate cancer cells. AhR has also been reported to interact with the Src signaling pathway during prostate development. c-Src protein kinase is associated with the AhR complex in the cytosol and upon ligand binding to AhR, c-Src is activated and released from the complex. AhR has also been shown to regulate AR signaling which remains functionally important in the development and progression of prostate cancer. We provide evidence that co-inhibition of AhR and Src abolish AR activity. Evaluation of total protein and cellular fractions revealed decreased pAR expression and AR nuclear localization. Assays utilizing an androgen responsive element (ARE) and qRT-PCR analysis of AR genes revealed decreased AR promoter activity and transcriptional activity in the presence of both AhR and Src inhibitors. Furthermore, co-inhibition of AhR and Src reduced the growth of prostate cancer cells compared to individual treatments. Several studies have revealed that AhR and Src individually inhibit cellular proliferation. However, this study is the first to suggest simultaneous inhibition of AhR and Src to inhibit AR signaling and prostate cancer cell growth.
NMR spectroscopy of filtered serum of prostate cancer: A new frontier in metabolomics.
Kumar, Deepak; Gupta, Ashish; Mandhani, Anil; Sankhwar, Satya Narain
2016-09-01
To address the shortcomings of digital rectal examinations (DRE), serum prostate-specific antigen (PSA), and trans-rectal ultrasound (TRUS) for precise determination of prostate cancer (PC) and differentiation from benign prostatic hyperplasia (BPH), we applied (1) H-nuclear magnetic resonance (NMR) spectroscopy as a surrogate tactic for probing and prediction of PC and BPH. The study comprises 210 filtered sera from suspected PC, BPH, and a healthy subjects' cohort (HC). The filtered serum approach delineates to identify and quantify 52 metabolites using (1) H NMR spectroscopy. All subjects had undergone clinical evaluations (DRE, PSA, and TRUS) followed by biopsy for Gleason score, if needed. NMR-measured metabolites and clinical evaluation data were examined separately using linear multivariate discriminant function analysis (DFA) to probe the signature descriptors for each cohort. DFA indicated that glycine, sarcosine, alanine, creatine, xanthine, and hypoxanthine were able to determine abnormal prostate (BPH + PC). DFA-based classification presented high precision (86.2% by NMR and 68.1% by clinical laboratory method) in discriminating HC from BPH + PC. DFA reveals that alanine, sarcosine, creatinine, glycine, and citrate were able to discriminate PC from BPH. DFA-based categorization exhibited high accuracy (88.3% by NMR and 75.2% by clinical laboratory method) to differentiate PC from BPH. (1) H NMR-based metabolic profiling of filtered-serum sample appears to be assuring, swift, and least-invasive for probing and prediction of PC and BPH with its signature metabolic profile. This novel technique is not only on a par with histopathological evaluation of PC determination but is also comparable to liquid chromatography-based mass spectrometry to identify the metabolites. Prostate 76:1106-1119, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiaofeng, E-mail: xyang43@emory.edu; Rossi, Peter; Ogunleye, Tomi
2014-11-01
Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approachmore » that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy.« less
Yang, Xiaofeng; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Mao, Hui; Curran, Walter J.; Liu, Tian
2014-01-01
Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy. PMID:25370648
Null activity of selenium and vitamin e as cancer chemopreventive agents in the rat prostate.
McCormick, David L; Rao, K V N; Johnson, William D; Bosland, Maarten C; Lubet, Ronald A; Steele, Vernon E
2010-03-01
To evaluate the potential efficacy of selenium and vitamin E as inhibitors of prostate carcinogenesis, four chemoprevention studies using a common protocol were done in a rat model of androgen-dependent prostate cancer. After stimulation of prostate epithelial cell proliferation by a sequential regimen of cyproterone acetate followed by testosterone propionate, male Wistar-Unilever rats received a single i.v. injection of N-methyl-N-nitrosourea (MNU) followed by chronic androgen stimulation via subcutaneous implantation of testosterone pellets. At 1 week post-MNU, groups of carcinogen-treated rats (39-44/group) were fed either a basal diet or a basal diet supplemented with l-selenomethionine (3 or 1.5 mg/kg diet; study 1), dl-alpha-tocopherol (vitamin E, 4,000 or 2,000 mg/kg diet; study 2), l-selenomethionine + vitamin E (3 + 2,000 mg/kg diet or 3 + 500 mg/kg diet; study 3), or selenized yeast (target selenium levels of 9 or 3 mg/kg diet; study 4). Each chemoprevention study was terminated at 13 months post-MNU, and prostate cancer incidence was determined by histopathologic evaluation. No statistically significant reductions in prostate cancer incidence were identified in any group receiving dietary supplementation with selenium and/or vitamin E. These data do not support the hypotheses that selenium and vitamin E are potent cancer chemopreventive agents in the prostate, and when considered with the recent clinical data reported in the Selenium and Vitamin E Cancer Prevention Trial (SELECT), show the predictive nature of this animal model for human prostate cancer chemoprevention.
NASA Astrophysics Data System (ADS)
Brock, Kristy K.; Ménard, Cynthia; Hensel, Jennifer; Jaffray, David A.
2006-03-01
Magnetic resonance imaging (MRI) with an endorectal receiver coil (ERC) provides superior visualization of the prostate gland and its surrounding anatomy at the expense of large anatomical deformation. The ability to correct for this deformation is critical to integrate the MR images into the CT-based treatment planning for radiotherapy. The ability to quantify and understand the physiological motion due to large changes in rectal filling can also improve the precision of image-guided procedures. The purpose of this study was to understand the biomechanical relationship between the prostate, rectum, and bladder using a finite element-based multi-organ deformable image registration method, 'Morfeus' developed at our institution. Patients diagnosed with prostate cancer were enrolled in the study. Gold seed markers were implanted in the prostate and MR scans performed with the ERC in place and its surrounding balloon inflated to varying volumes (0-100cc). The prostate, bladder, and rectum were then delineated, converted into finite element models, and assigned appropriate material properties. Morfeus was used to assign surface interfaces between the adjacent organs and deform the bladder and rectum from one position to another, obtaining the position of the prostate through finite element analysis. This approach achieves sub-voxel accuracy of image co-registration in the context of a large ERC deformation, while providing a biomechanical understanding of the multi-organ physiological relationship between the prostate, bladder, and rectum. The development of a deformable registration strategy is essential to integrate the superior information offered in MR images into the treatment planning process.
Garraway, Isla P; Sun, Wenyi; Tran, Chau P; Perner, Sven; Zhang, Bao; Goldstein, Andrew S; Hahm, Scott A; Haider, Maahum; Head, Christian S; Reiter, Robert E; Rubin, Mark A; Witte, Owen N
2010-01-01
BACKGROUND Prostate stem/progenitor cells function in glandular development and maintenance. They may be targets for tumor initiation, so characterization of these cells may have therapeutic implications. Cells from dissociated tissues that form spheres in vitro often represent stem/progenitor cells. A subset of human prostate cells that form prostaspheres were evaluated for self-renewal and tissue regeneration capability in the present study. METHODS Prostaspheres were generated from 59 prostatectomy specimens. Lineage marker expression and TMPRSS-ERG status was determined via immunohistochemistry and fluorescence in situ hybridization (FISH). Subpopulations of prostate epithelial cells were isolated by cell sorting and interrogated for sphere-forming activity. Tissue regeneration potential was assessed by combining sphere-forming cells with rat urogenital sinus mesenchyme (rUGSM) subcutaneously in immunocompromised mice. RESULTS Prostate tissue specimens were heterogeneous, containing both benign and malignant (Gleason 3–5) glands. TMPRSS-ERG fusion was found in approximately 70% of cancers examined. Prostaspheres developed from single cells at a variable rate (0.5–4%) and could be serially passaged. A basal phenotype (CD44+CD49f+CK5+p63+CK8−AR−PSA−) was observed among sphere-forming cells. Subpopulations of prostate cells expressing tumor-associated calcium signal transducer 2 (Trop2), CD44, and CD49f preferentially formed spheres. In vivo implantation of sphere-forming cells and rUGSM regenerated tubular structures containing discreet basal and luminal layers. The TMPRSS-ERG fusion was absent in prostaspheres derived from fusion-positive tumor tissue, suggesting a survival/growth advantage of benign prostate epithelial cells. CONCLUSION Human prostate sphere-forming cells self-renew, have tissue regeneration capability, and represent a subpopulation of basal cells. Prostate 70: 491–501, 2010. © 2009 Wiley-Liss, Inc. PMID:19938015
MO-FG-210-02: Implementation of Image-Guided Prostate HDR Brachytherapy Using MR-Ultrasound Fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Libby, B.
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
Mengele, K; Harbeck, N; Reuning, U; Magdolen, V; Schmitt, M
2005-08-01
Proteolytic factors belonging t the plasminogen activator family (plasmin, u-PA, t-PA, u-PAR, PAI-1, and PAI-2), which usually are involved in blood clotting and degradation of blood clots, are also present in healthy and diseased tissue of the kidney, lung, liver, gastro-intestinal tract, breast, prostate, ovary, and brain. These factors are engaged in brain development, angiogenesis and vascular invasion, wound healing as well as in placenta development and embryogenesis. Plasminogen activators u-PA and t-PA, their inhibitors PAI-1 and PAI-2, and the u-PA-receptor (u-PAR, CD87) are often elevated in solid malignant tumour tissues compared to their normal counterparts. In breast cancer patients, an elevated tumour tissue extract antigen content of u-PA, PAI-1, and u-PAR is associated with increased tumour aggressiveness and poor prognosis; in contrary, an elevated content of t-PA and PAI-2 indicates a favourable prognosis. For clinical relevant determination of these proteolytic factors in tumour tissue extracts, only enzymo-immunometric tests (ELISA) are recommended. Enzymometric and enzymographic tests are actually conducted only in an experimental, preclinical context.
Recuit thermique rapide de semi-conducteur par énergie micro-onde
NASA Astrophysics Data System (ADS)
Covas, M.; Gay, H. C.
1993-05-01
This paper proposes a new technique for rapid thermal annealing of semi-conductors. This technique is based on microwave energy, and offers the same advantages as the rapid thermal annealing by incoherent light, in terms of rapidity, and contamination. However, our technique reduces considerably the required energy for the annealing process. This technique has been compared to the rapid thermal by incoherent light: lab experiments, carried out on boron implanted silicon samples, showed that a power gain ratio of about 10 can be achieved. Nous proposons une méthode de recuit thermique rapide du silicium par énergie micro-onde. Cette technique offre les mêmes avantages que les traitements thermiques rapides par lumière incohérente, c'est-à-dire des durées de chauffage très brèves, limitant ainsi la diffusion des dopants, et un traitement plaquette par plaquette : les risques de contamination de tout un lot sont ainsi éliminés. De plus notre méthode requiert une faible énergie : pour parvenir à des recuits de qualité similaire à celle obtenue dans des fours de recuit rapide à lampes il faut un flux de puissance 10 fois plus faible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sampson, Andrew; Le Yi; Williamson, Jeffrey F.
2012-02-15
Purpose: To demonstrate potential of correlated sampling Monte Carlo (CMC) simulation to improve the calculation efficiency for permanent seed brachytherapy (PSB) implants without loss of accuracy. Methods: CMC was implemented within an in-house MC code family (PTRAN) and used to compute 3D dose distributions for two patient cases: a clinical PSB postimplant prostate CT imaging study and a simulated post lumpectomy breast PSB implant planned on a screening dedicated breast cone-beam CT patient exam. CMC tallies the dose difference, {Delta}D, between highly correlated histories in homogeneous and heterogeneous geometries. The heterogeneous geometry histories were derived from photon collisions sampled inmore » a geometrically identical but purely homogeneous medium geometry, by altering their particle weights to correct for bias. The prostate case consisted of 78 Model-6711 {sup 125}I seeds. The breast case consisted of 87 Model-200 {sup 103}Pd seeds embedded around a simulated lumpectomy cavity. Systematic and random errors in CMC were unfolded using low-uncertainty uncorrelated MC (UMC) as the benchmark. CMC efficiency gains, relative to UMC, were computed for all voxels, and the mean was classified in regions that received minimum doses greater than 20%, 50%, and 90% of D{sub 90}, as well as for various anatomical regions. Results: Systematic errors in CMC relative to UMC were less than 0.6% for 99% of the voxels and 0.04% for 100% of the voxels for the prostate and breast cases, respectively. For a 1 x 1 x 1 mm{sup 3} dose grid, efficiency gains were realized in all structures with 38.1- and 59.8-fold average gains within the prostate and breast clinical target volumes (CTVs), respectively. Greater than 99% of the voxels within the prostate and breast CTVs experienced an efficiency gain. Additionally, it was shown that efficiency losses were confined to low dose regions while the largest gains were located where little difference exists between the homogeneous and heterogeneous doses. On an AMD 1090T processor, computing times of 38 and 21 sec were required to achieve an average statistical uncertainty of 2% within the prostate (1 x 1 x 1 mm{sup 3}) and breast (0.67 x 0.67 x 0.8 mm{sup 3}) CTVs, respectively. Conclusions: CMC supports an additional average 38-60 fold improvement in average efficiency relative to conventional uncorrelated MC techniques, although some voxels experience no gain or even efficiency losses. However, for the two investigated case studies, the maximum variance within clinically significant structures was always reduced (on average by a factor of 6) in the therapeutic dose range generally. CMC takes only seconds to produce an accurate, high-resolution, low-uncertainly dose distribution for the low-energy PSB implants investigated in this study.« less
Penzkofer, Tobias; Tempany-Afdhal, Clare M.
2013-01-01
It is now universally recognized that many prostate cancers are over-diagnosed and over-treated. The European Randomized Study of Screening for Prostate Cancer (ERSPC) from 2009 evidenced that, to save one man from death of prostate cancer, over 1,400 men had to be screened, and 48 had to undergo treatment. Detection of prostate cancer is traditionally based upon digital rectal examination (DRE) and measuring serum prostate specific antigen (PSA), followed by ultrasound guided biopsy. The primary role of imaging for the detection and diagnosis of prostate cancer has been transrectal ultrasound (TRUS) guidance during biopsy. MRI has traditionally been used primarily for staging disease in men with biopsy proven cancer. It is has a well-established role in detecting T3 disease, planning radiation therapy, especially 3D conformal or intensity modulated external beam radiation therapy (IMRT), and planning and guiding interstitial seed implant or brachytherapy. New advances have now established prostate MRI can accurately characterize focal lesions within the gland, an ability that has led to new opportunities for improved cancer detection and guidance for biopsy. There are two new approaches to prostate biopsy are under investigation both use pre-biopsy MRI to define potential targets for sampling and then the biopsy is performed either with direct real-time MR guidance (in-bore) or MR fusion/registration with TRUS images (out-of-bore). In-bore or out-of-bore MRI-guided prostate biopsies have the advantage of using the MR target definition for accurate localization and sampling of targets or suspicious lesions. The out-of-bore method uses combined MRI/TRUS with fusion software that provided target localization and increases the sampling accuracy for TRUS-guided biopsies by integrating prostate MRI information with TRUS. Newer parameters for each imaging modality such as sonoelastography or shear wave elastography (SWE), contrast enhanced US (CEUS) and MRI-elastography, show promise to further enrich data sets. PMID:24000133
SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, F Maria; Podder, T; Yu, Y
Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostatemore » HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.« less
Expression of a model gene in prostate cancer cells lentivirally transduced in vitro and in vivo.
Bastide, C; Maroc, N; Bladou, F; Hassoun, J; Maitland, N; Mannoni, P; Bagnis, C
2003-01-01
In a preclinical model for prostate cancer gene therapy, we have tested lentiviral vectors as a practical possibility for the transfer and long-term expression of the EGFP gene both in vitro and in vivo. The human prostate cancer cell lines DU145 and PC3 were transduced using experimental conditions which permitted analysis of the expression from a single proviral vector per cell. The transduced cells stably expressed the EGFP transgene for 4 months. After injection of the transduced cell populations into Nod-SCID mice a decrease in EGFP was only observed in a minority of cases, while the majority of tumors maintained transgene expression at in vitro levels. In vivo injection of viral vector preparations directly into pre-established subcutaneous or orthotopic tumor masses, obtained by implantation of untransduced PC3 and DU145 cells led to a high transduction efficiency. While the efficiency of direct intratumoral transduction was proportional to the dose of virus injected, the results indicated some technical limitations inherent in these approaches to prostate cancer gene therapy.
Scatena, Caroline D; Hepner, Mischa A; Oei, Yoko A; Dusich, Joan M; Yu, Shang-Fan; Purchio, Tony; Contag, Pamela R; Jenkins, Darlene E
2004-05-15
Animal experiments examining hormone-sensitive metastatic prostate cancer using the human LNCaP cell line have been limited to endpoint analyses. To permit longitudinal studies, we generated a luciferase-expressing cell line and used bioluminescent imaging (BLI) to non-invasively monitor the in vivo growth of primary LNCaP tumors and metastasis. LNCaP.FGC cells were transfected to constitutively express firefly luciferase. LNCaP-luc-M6 cells were tested for bioluminescent signal intensity and hormone responsiveness in vitro. The cells were implanted in subcutaneous and orthotopic sites in SCID-bg mice and imaged over time. The LNCaP-luc-M6 cells formed subcutaneous and orthotopic tumors in SCID-bg mice, and nearly all tumor-bearing animals developed pulmonary metastases. Early detection and temporal growth of primary tumors and metastatic lesions was successfully monitored by BLI. The LNCaP-luc-M6 cell line is a bioluminescent, hormone-sensitive prostate cancer cell line applicable for BLI studies to non-invasively monitor subcutaneous and orthotopic prostate tumor growth and metastasis in vivo. Copyright 2004 Wiley-Liss, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sugar, E Neubauer; Buzurovic, I; O’Farrell, D
2015-06-15
Purpose: To compare the dosimetry of a standard rectilinear and an adaptive technique used in I125 prostate seed implants. Methods: To achieve favorable dosimetry in prostate implants we used adaptive needle updates to match actual positions in real-time. The seed locations were optimized based on actual needle locations. The seeds were delivered automatically with a robotic device seedSelectron™ (Elekta Brachytherapy). In this study, we evaluated the former approach against the standard rectilinear technique in which the needles have a parallel distribution. The treatment plans for 10 patients were analyzed. For comparison, the actual treatment plans were revised so each needlemore » was repositioned to its original parallel location through the template. The analysis was performed by comparing the target coverage and dose to the organs at risk. The comparison was done using the following planning goals: the target D90> 90%, V100% > 90%, V50% <70% and V200% <30%; the urethra V125% < 1cm3 and V150%= 0cm3; and the Rectum V100%<1cm3 and V69% < 8cm3. The prescription dose to the target was 145Gy. Results: The average target volume and number of seeds were 44.39cm3(SD=11.14) and 74(SD=12), respectively. The D90 for adaptive and rectilinear plans was 159.9Gy(SD=2.99) and 155.53Gy(SD=4.04) resulting in a 2.74% difference for the average target coverage. A similar difference (1.75%) was noticed in the target V100[%]. No significant difference was noticed in the dose to the urethra and rectum. All planning goals were met with both the adaptive and rectilinear approach for each plan. Conclusion: The study reveals enhanced coverage of the target when using the adaptive needle adjustments as compared to the rectilinear approach for the analyzed cases. However, the differences in dosimetry did not translate to meaningful clinical outcomes.« less
A dosimetric comparison of {sup 169}Yb versus {sup 192}Ir for HDR prostate brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lymperopoulou, G.; Papagiannis, P.; Sakelliou, L.
2005-12-15
For the purpose of evaluating the use of {sup 169}Yb for prostate High Dose Rate brachytherapy (HDR), a hypothetical {sup 169}Yb source is assumed with the exact same design of the new microSelectron source replacing the {sup 192}Ir active core by pure {sup 169}Yb metal. Monte Carlo simulation is employed for the full dosimetric characterization of both sources and results are compared following the AAPM TG-43 dosimetric formalism. Monte Carlo calculated dosimetry results are incorporated in a commercially available treatment planning system (SWIFT{sup TM}), which features an inverse treatment planning option based on a multiobjective dose optimization engine. The qualitymore » of prostate HDR brachytherapy using the real {sup 192}Ir and hypothetical {sup 169}Yb source is compared in a comprehensive analysis of different prostate implants in terms of the multiobjective dose optimization solutions as well as treatment quality indices such as Dose Volume Histograms (DVH) and the Conformal Index (COIN). Given that scattering overcompensates for absorption in intermediate photon energies and distances in the range of interest to prostate HDR brachytherapy, {sup 169}Yb proves at least equivalent to {sup 192}Ir irrespective of prostate volume. This has to be evaluated in view of the shielding requirements for the {sup 169}Yb energies that are minimal relative to that for {sup 192}Ir.« less
Giandini, Tommaso; Panaino, Costanza M V; Avuzzi, Barbara; Morlino, Sara; Villa, Sergio; Bedini, Nice; Carabelli, Gabriele; Frasca, Sarah C; Romanyukha, Anna; Rosenfeld, Anatoly; Pignoli, Emanuele; Valdagni, Riccardo; Carrara, Mauro
2017-03-24
To validate and apply a method for the quantification of breathing-induced prostate motion (BIPM) for patients treated with radiotherapy and implanted with electromagnetic transponders for prostate localization and tracking. For the analysis of electromagnetic transponder signal, dedicated software was developed and validated with a programmable breathing simulator phantom. The software was then applied to 1,132 radiotherapy fractions of 30 patients treated in supine position, and to a further 61 fractions of 2 patients treated in prone position. Application of the software in phantom demonstrated reliability of the developed method in determining simulated breathing frequencies and amplitudes. For supine patients, the in vivo analysis of BIPM resulted in median (maximum) amplitudes of 0.10 mm (0.35 mm), 0.24 mm (0.66 mm), and 0.17 mm (0.61 mm) in the left-right (LR), cranio-caudal (CC), and anterior-posterior (AP) directions, respectively. Breathing frequency ranged between 7.73 and 29.43 breaths per minute. For prone patients, the ranges of the BIPM amplitudes were 0.1-0.5 mm, 0.5-1.3 mm, and 0.7-1.7 mm in the LR, CC, and AP directions, respectively. The developed method was able to detect the BIPM with sub-millimeter accuracy. While for patients treated in supine position the BIPM represents a reduced source of treatment uncertainty, for patients treated in prone position, it can be higher than 3 mm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zauls, A. Jason; Ashenafi, Michael S.; Onicescu, Georgiana
2011-11-15
Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method,more » the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.« less
Hanada, Takashi; Yorozu, Atsunori; Shinya, Yukiko; Kuroiwa, Nobuko; Ohashi, Toshio; Saito, Shiro; Shigematsu, Naoyuki
2016-01-01
To broaden the current understanding of radiation exposure and risk and to provide concrete evidence of radiation safety related to (125)I seed implantation. Direct radiation exposure measurements were obtained from dosimeters provided to 25 patients who underwent (125)I seed implantation, along with their family members. The estimated lifetime exposure dose and the precaution time for holding children near the patient's chest were calculated in two study periods. During the first and second study period, the mean estimated lifetime exposure doses were, respectively, 7.61 (range: 0.45, 20.21) mSv and 6.84 (range: 0.41, 19.20) mSv for patients, and 0.19 (range: 0.02, 0.54) mSv and 0.25 (range: 0.04, 1.00) mSv for family members. The mean ratios of first and second period measurements were 1.05 (range: 0.44, 3.18) for patients and 1.82 (range: 0.21, 7.04) for family members. The corresponding absolute differences between first and second period measurements were -0.77 (range: -11.40, 7.63) mSv and 0.06 (range: -0.26, 0.79) mSv, respectively. Assuming a dose limit of 1 mSv, the precaution times for holding a child every day of the first and second periods were 250.9 (range: 71.3, 849.4) min and 275.2 (range: 75.0, 883.4) min, respectively. Assuming a dose limit of 0.5 mSv, the corresponding precaution times were 179.0 (range: 35.6, 811.5) min and 178.9 (range: 37.5, 1131.8) min, respectively. Our study demonstrated low radiation exposures to family members of patients undergoing (125)I prostate implantation. It was clear that (125)I seed implantation did not pose a threat to the safety of family members. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, T; Wang, J; Frank, S
Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGRmore » sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3.2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.« less
Kweon, Eui Yong; Ahn, Min; Lee, Dong Wook; You, In Cheon; Kim, Min Jung; Cho, Nam Chun
2009-01-01
The purpose of this study is to report the features of operating microscope light-induced retinal phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens (TSS PC-IOL) implantation. The charts of 118 patients who underwent TSS PC-IOL implantation surgery at Chonbuk National University Hospital (Jeonju, Korea) between March 1999 and February 2008 were retrospectively reviewed. Fourteen patients underwent combined 3-port pars plana vitrectomy and TSS PC-IOL implantation (vitrectomy group), and 104 patients underwent TSS PC-IOL implantation only (nonvitrectomy group). All surgeries were performed under the same coaxial illuminated microscope. All diagnoses were confirmed through careful fundus examination and fluorescein angiography (FA). Diagnoses of retinal phototoxic maculopathy were established in 10 (8.47%) of 118 TSS PC-IOL implantation cases. Phototoxic maculopathy occurred more frequently in the vitrectomy group than in the nonvitrectomy group (6/14 versus 4/104, respectively; P < 0.001, chi-square = 24.21). Affected patients reported decreased vision and were found to have coarse alterations of the retinal pigment epithelium (RPE). In 5 of the phototoxic maculopathy cases (50%), the visual acuity was 20/200 or worse. Operating microscope light-induced retinal phototoxic maculopathy can occur more frequently after TSS PC-IOL implantation than after casual cataract surgery, especially when TSS PC-IOL is combined with vitrectomy surgery. Surgeons should take precautions to prevent retinal phototoxicity after TSS PC-IOL implantation and vitrectomy.
Furstoss, C; Bertrand, M J; Poon, E; Reniers, B; Pignol, J P; Carrier, J F; Beaulieu, L; Verhaegen, F
2008-07-01
This work consists of studying the interseed and tissue composition effects for two model iodine seeds: the IBt Interseed-125 and the 6711 model seed. Three seeds were modeled with the MCNP MC code in a water sphere to evaluate the interseed effect. The dose calculated at different distances from the centre was compared to the dose summed when the seeds were simulated separately. The tissue composition effect was studied calculating the radial dose function for different tissues. Before carrying out post-implant studies, the absolute dose calculated by MC was compared to experiment results: with LiF TLDs in an acrylic breast phantom and with an EBT Gafchromic film placed in a water tank. Afterwards, the TG-43 approximation effects were studied for a prostate and breast post-implant. The interseed effect study shows that this effect is more important for model 6711 (15%) than for IBt (10%) due to the silver rod in 6711. For both seed models the variations of the radial dose function as a function of the tissue composition are quasi similar. The absolute dose comparisons between MC calculations and experiments give good agreement (inferior to 3% in general). For the prostate and breast post-implant studies, a 10% difference between MC calculations and the TG-43 is found for both models of seeds. This study shows that the differences in dose distributions between TG43 and MC are quite similar for the two models of seeds and are about 10% for the studied post-implant treatments. © 2008 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neal, Robert E., E-mail: robert.neal@alfred.org.au; Smith, Ryan L., E-mail: ryan.smith@wbrc.org.au; Kavnoudias, Helen, E-mail: H.Kavnoudias@alfred.org.au
2013-12-15
Purpose: Electroporation-based therapies deliver brief electric pulses into a targeted volume to destabilize cellular membranes. Nonthermal irreversible electroporation (IRE) provides focal ablation with effects dependent on the electric field distribution, which changes in heterogeneous environments. It should be determined if highly conductive metallic implants in targeted regions, such as radiotherapy brachytherapy seeds in prostate tissue, will alter treatment outcomes. Theoretical and experimental models determine the impact of prostate brachytherapy seeds on IRE treatments. Materials and Methods: This study delivered IRE pulses in nonanimal, as well as in ex vivo and in vivo tissue, with and in the absence of expiredmore » radiotherapy seeds. Electrical current was measured and lesion dimensions were examined macroscopically and with magnetic resonance imaging. Finite-element treatment simulations predicted the effects of brachytherapy seeds in the targeted region on electrical current, electric field, and temperature distributions. Results: There was no significant difference in electrical behavior in tissue containing a grid of expired radiotherapy seeds relative to those without seeds for nonanimal, ex vivo, and in vivo experiments (all p > 0.1). Numerical simulations predict no significant alteration of electric field or thermal effects (all p > 0.1). Histology showed cellular necrosis in the region near the electrodes and seeds within the ablation region; however, there were no seeds beyond the ablation margins. Conclusion: This study suggests that electroporation therapies can be implemented in regions containing small metallic implants without significant changes to electrical and thermal effects relative to use in tissue without the implants. This supports the ability to use IRE as a salvage therapy option for brachytherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milickovic, Natasa; Mavroidis, Panayiotis; Tselis, Nikolaos
2011-09-15
Purpose: Modern HDR brachytherapy treatment for prostate cancer based on the 3D ultrasound (U/S) plays increasingly important role. The purpose of this study is to investigate possible patient movement and anatomy alteration between the clinical image set acquisition, made after the needle implantation, and the patient irradiation and their influence on the quality of treatment. Methods: The authors used 3D U/S image sets and the corresponding treatment plans based on a 4D-treatment planning procedure: plans of 25 patients are obtained right after the needle implantation (clinical plan is based on this 3D image set) and just before and after themore » treatment delivery. The authors notice the slight decrease of treatment quality with increase of time gap between the clinical image set acquisition and the patient irradiation. 4D analysis of dose-volume-histograms (DVHs) for prostate: CTV1 = PTV, and urethra, rectum, and bladder as organs at risk (OARs) and conformity index (COIN) is presented, demonstrating the effect of prostate, OARs, and needles displacement. Results: The authors show that in the case that the patient body movement/anatomy alteration takes place, this results in modification of DVHs and radiobiological parameters, hence the plan quality. The observed average displacement of needles (1 mm) and of prostate (0.57 mm) is quite small as compared with the average displacement noted in several other reports [A. A. Martinez et al., Int. J. Radiat. Oncol., Biol., Phys. 49(1), 61-69 (2001); S. J. Damore et al., Int. J. Radiat. Oncol., Biol., Phys. 46(5), 1205-1211 (2000); P. J. Hoskin et al., Radiotherm. Oncol. 68(3), 285-288 (2003); E. Mullokandov et al., Int. J. Radiat. Oncol., Biol., Phys. 58(4), 1063-1071 (2004)] in the literature. Conclusions: Although the decrease of quality of dosimetric and radiobiological parameters occurs, this does not cause clinically unacceptable changes to the 3D dose distribution, according to our clinical protocol.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polan, D; Kamp, J; Lee, JY
Purpose: To perform validation and commissioning of a commercial deformable image registration (DIR) algorithm (Velocity, Varian Medical Systems) for numerous clinical sites using single and multi-modality images. Methods: In this retrospective study, the DIR algorithm was evaluated for 10 patients in each of the following body sites: head and neck (HN), prostate, liver, and gynecological (GYN). HN DIRs were evaluated from planning (p)CT to re-pCT and pCTs to daily CBCTs using dice similarity coefficients (DSC) of corresponding anatomical structures. Prostate DIRs were evaluated from pCT to CBCTs using DSC and target registration error (TRE) of implanted RF beacons within themore » prostate. Liver DIRs were evaluated from pMR to pCT using DSC and TRE of vessel bifurcations. GYN DIRs were evaluated between fractionated brachytherapy MRIs using DSC of corresponding anatomical structures. Results: Analysis to date has given average DSCs for HN pCT-to-(re)pCT DIR for the brainstem, cochleas, constrictors, spinal canal, cord, esophagus, larynx, parotids, and submandibular glands as 0.88, 0.65, 0.67, 0.91, 0.77, 0.69, 0.77, 0.87, and 0.71, respectively. Average DSCs for HN pCT-to-CBCT DIR for the constrictors, spinal canal, esophagus, larynx, parotids, and submandibular glands were 0.64, 0.90, 0.62, 0.82, 0.75, and 0.69, respectively. For prostate pCT-to-CBCT DIR the DSC for the bladder, femoral heads, prostate, and rectum were 0.71, 0.82, 0.69, and 0.61, respectively. Average TRE using implanted beacons was 3.35 mm. For liver pCT-to-pMR, the average liver DSC was 0.94 and TRE was 5.26 mm. For GYN MR-to-MR DIR the DSC for the bladder, sigmoid colon, GTV, and rectum were 0.79, 0.58, 0.67, and 0.76, respectively. Conclusion: The Velocity DIR algorithm has been evaluated over a number of anatomical sites. This work functions to document the uncertainties in the DIR in the commissioning process so that these can be accounted for in the development of downstream clinical processes. This work was supported in part by a co-development agreement with Varian Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lilleby, Wolfgang, E-mail: wolfgang.lilleby@ous-hf.no; Tafjord, Gunnar; Raabe, Nils K.
2012-07-01
Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgenmore » deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal external radiotherapy and long-term ADT. High-quality implants can be achieved by a trained specialized team at a high-turnover center using transrectal ultrasound-based treatment plans with acceptable morbidity and complication rates.« less
Sánchez-Gómez, L M; Polo-deSantos, M; Gómez-Sancha, F; Luengo-Matos, S
2015-06-01
Interest in having alternatives in the treatment of benign prostate hyperplasia. To assess the efficacy and safety of the Urolift® system for treating the symptoms of benign prostate hyperplasia. Systematic review of the literature through searches on PubMed, Cochrane Library, CRD, Clinical Trials and EuroScan, collecting indicators of efficacy and safety. We included 5 case series and one clinical trial. The patients' mean age ranged from 65-74.3 years, and the mean prostate volume was 41-55cm3. The mean number of Urolif® implants was 3.7-5.5. The maximum follow-up in months was 24, 12 (3 studies) and one (2 studies). Improvements were found in lower urinary tract symptoms, as measured with the International Prostate Symptom Score, Benign Prostatic Hyperplasia Impact Index (BPHII), maximum urinary flow (Qmax) and postvoid residual (PVR) volume. Improvements were in found sexual dysfunction symptoms, as measured with the Sexual Health Inventory for Men (SHIM) and the Male Sexual Health Questionnaire or Ejaculatory Dysfunction (MHSQ-EjD), and in quality of life (QoL). In the clinical trial, the differences were significant for International Prostate Symptom Score, BPHII, Qmax and QoL (p<.05). The adverse effects were mild. Although the quality of evidence is low, Urolift® constitutes a good therapeutic alternative for patients with benign prostate hyperplasia. The short to medium-term results show that the technique contributes to improving lower urinary tract symptoms, with no relevant side effects, does not affect sexual function and improves quality of life. Further research is required, especially on long-term results. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
McGeachy, P; Khan, R
2012-07-01
In early stage prostate cancer, low dose rate (LDR) prostate brachytherapy is a favorable treatment modality, where small radioactive seeds are permanently implanted throughout the prostate. Treatment centres currently rely on a commercial optimization algorithm, IPSA, to generate seed distributions for treatment plans. However, commercial software does not allow the user access to the source code, thus reducing the flexibility for treatment planning and impeding any implementation of new and, perhaps, improved clinical techniques. An open source genetic algorithm (GA) has been encoded in MATLAB to generate seed distributions for a simplified prostate and urethra model. To assess the quality of the seed distributions created by the GA, both the GA and IPSA were used to generate seed distributions for two clinically relevant scenarios and the quality of the GA distributions relative to IPSA distributions and clinically accepted standards for seed distributions was investigated. The first clinically relevant scenario involved generating seed distributions for three different prostate volumes (19.2 cc, 32.4 cc, and 54.7 cc). The second scenario involved generating distributions for three separate seed activities (0.397 mCi, 0.455 mCi, and 0.5 mCi). Both GA and IPSA met the clinically accepted criteria for the two scenarios, where distributions produced by the GA were comparable to IPSA in terms of full coverage of the prostate by the prescribed dose, and minimized dose to the urethra, which passed straight through the prostate. Further, the GA offered improved reduction of high dose regions (i.e hot spots) within the planned target volume. © 2012 American Association of Physicists in Medicine.
MO-FG-210-00: US Guided Systems for Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Z.
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamb, J.
2015-06-15
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
Mundy, Anthony R; Andrich, Daniela E
2010-05-01
To report our experience of bladder neck injuries, which are a well recognized but rare consequence of pelvic fracture-related trauma to the lower urinary tract, as we have been unable to find any reference in the English literature to their specific nature, cause and management in adults. In the last 10 years we have treated 15 men with bladder neck injuries after pelvic fracture. Two were treated at our centre by delayed primary repair. Thirteen were initially treated elsewhere and presented to us 3 months to 5 years after their injury with intractable incontinence and various other symptoms most notably recurrent urinary infection and gross haematuria. Twelve of the injuries were at or close to the anterior midline and associated with lateral compression fractures or 'open-book' injuries. Five of them were confined to the bladder neck and prostatic urethra; the other seven extended into the subprostatic urethra. Four of these were associated with a coincidental typical rupture of the posterior urethra. All had an associated cavity involving the anterior disruption of the pelvic ring. Two of the injuries, following particularly severe trauma, were a simultaneous complete transection of the bladder neck and of the bulbo-membranous urethra with a sequestered prostate between. We have seen this in children before but not in adults. Another injury, also after particularly severe trauma, was an avulsion of the anterior aspect of the prostate. We have not seen this described before. Fourteen patients underwent lower urinary tract reconstruction and one underwent a Mitrofanoff procedure. All of the 14 had a layered reconstruction of the prostate and bladder neck and in 13, this was supplemented with an omental wrap. In all patients with an anterior midline rupture, the primary injury appeared to be to the prostate and prostatic urethra with secondary involvement of the bladder neck and the subprostatic urethra. The Mitrofanoff procedure was successful. Of the 14 patients with a layered reconstruction one, without an omental wrap, broke down but was successfully repaired on a subsequent occasion. The four patients who also had a ruptured urethra had a simultaneous bulbo-prostatic anastomotic urethroplasty, two of which required further attention. Eight of the 14 reconstructed patients underwent implantation of an artificial urinary sphincter (AUS) for sphincter weakness incontinence, in seven of whom this was successful. Two of these had previously undergone implantation of an AUS with an unsatisfactory outcome and were made continent by bladder neck reconstruction. The other six patients had acceptable urinary incontinence by reconstruction of the bladder neck and urethra alone. The primary injury is to the prostate and prostatic urethra. The bladder neck and subprostatic urethra are involved secondarily by extension. These injuries have a particular cause and a particular location with a predictable outcome. They need to be identified and treated promptly as they do not heal spontaneously and otherwise cause considerable morbidity. We also describe two particular types of bladder neck injury that we have not seen described before in adults.
Innovative approaches to glaucoma management of Boston keratoprosthesis type 1.
Vajaranant, Thasarat S; Liu, Jessica; Wilensky, Jacob; Cortina, M Soledad; Aref, Ahmad A
2016-09-01
Glaucoma remains a prevalent disorder and visual limiting factor after Boston keratoprosthesis type 1 implantation. Patients with glaucoma have worse initial and late visual acuity outcomes after otherwise successful keratoprosthesis implantation. Management of glaucoma in the setting of a keratoprosthesis is challenging because of relatively rapid progression and an inability to accurately measure intraocular pressure (IOP). In addition, there are no standard guidelines for glaucoma surveillance and monitoring after keratoprosthesis surgery. This report provides a review of the current literature and offers innovative strategies that will overcome the challenges in managing glaucoma in the setting of a Boston keratoprosthesis type 1 implant. The topics that will be discussed in this section include alternative methods for IOP measurement, rationales and surgical techniques for a pars plana tube placement for glaucoma drainage device, effective medical and laser treatment, the risk for IOP elevations after YAG laser, and practical guides to glaucoma surveillance and monitoring.
Tuomela, Johanna M; Valta, Maija P; Väänänen, Kalervo; Härkönen, Pirkko L
2008-01-01
Background Metastatic prostate cancer is associated with a high morbidity and mortality but the spreading mechanisms are still poorly understood. The aminobisphosphonate alendronate, used to reduce bone loss, has also been shown to inhibit the invasion and migration of prostate cancer cells in vitro. We used a modified orthotopic PC-3 nude mouse tumor model of human prostate cancer to study whether alendronate affects prostate tumor growth and metastasis. Methods PC-3 cells (5 × 105) were implanted in the prostates of nude mice and the mice were treated with alendronate (0.5 mg/kg/day in PBS, s.c.) or vehicle for 4 weeks. After sacrifice, the sizes of tumor-bearing prostates were measured and the tumors and prostate-draining regional iliac and sacral lymph nodes were excised for studies on markers of proliferation, apoptosis, angiogenesis and lymphangiogenesis, using histomorphometry and immunohistochemistry. Results Tumor occurrence in the prostate was 73% in the alendronate-treated group and 81% in the control group. Mean tumor size (218 mm3, range: 96–485 mm3, n = 11) in the alendronate-treated mice was 41% of that in the control mice (513 mm3, range: 209–1350 mm3, n = 13) (p < 0.05). In the iliac and sacral lymph nodes of alendronate-treated mice, the proportion of metastatic area was only about 10% of that in control mice (p < 0.001). Immunohistochemical staining of tumor sections showed that alendronate treatment caused a marked decrease in the number of CD34-positive endothelial cells in tumors (p < 0.001) and an increase in that of ISEL positive apoptotic cells in tumors as well as in lymph node metastases (p < 0.05) compared with those in the vehicle-treated mice. The density of m-LYVE-1-stained lymphatic capillaries was not changed. Conclusion Our results demonstrate that alendronate treatment opposes growth of orthotopic PC-3 tumors and decreases tumor metastasis to prostate-draining lymph nodes. This effect could be at least partly explained by decreased angiogenesis and increased apoptosis. The results suggest that bisphosphonates have anti-tumoral and anti-invasive effects on primary prostate cancer. PMID:18371232
Fellin, Giovanni; Mirri, Maria A; Santoro, Luigi; Divan, Claudio; Mussari, Salvatore; Ziglio, Francesco; La Face, Beniamino; Barbera, Fernando; Buglione, Michela; Bandera, Laura; Ghedi, Barbara; Di Muzio, Nadia G; Losa, Andrea; Mangili, Paola; Nava, Luciano; Chiarlone, Renato; Ciscognetti, Nunzia; Gastaldi, Emilio; Cattani, Federica; Spoto, Ruggero; Vavassori, Andrea; Giglioli, Francesca R; Guarneri, Alessia; Cerboneschi, Valentina; Mignogna, Marcello; Paoluzzi, Mauro; Ravaglia, Valentina; Chiumento, Costanza; Clemente, Stefania; Fusco, Vincenzo; Santini, Roberto; Stefanacci, Marco; Mangiacotti, Francesco P; Martini, Marco; Palloni, Tiziana; Schinaia, Giuseppe; Lazzari, Grazia; Silvano, Giovanni; Magrini, Stefano; Ricardi, Umberto; Santoni, Riccardo; Orecchia, Roberto
2016-01-01
Objective: Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. Methods: Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 (125I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. 125I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan–Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. Results: Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p < 0.0001) and V100 (p = 0.09) were correlated with BFFS, with V100 effect significantly different between patients at low risk and those at intermediate/high risk (p = 0.04). Short follow-up and lack of toxicity data represent the main limitations for a global evaluation of LDR-BT. Conclusion: This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. Advances in knowledge: Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome. PMID:27384381
Fellin, Giovanni; Mirri, Maria A; Santoro, Luigi; Jereczek-Fossa, Barbara A; Divan, Claudio; Mussari, Salvatore; Ziglio, Francesco; La Face, Beniamino; Barbera, Fernando; Buglione, Michela; Bandera, Laura; Ghedi, Barbara; Di Muzio, Nadia G; Losa, Andrea; Mangili, Paola; Nava, Luciano; Chiarlone, Renato; Ciscognetti, Nunzia; Gastaldi, Emilio; Cattani, Federica; Spoto, Ruggero; Vavassori, Andrea; Giglioli, Francesca R; Guarneri, Alessia; Cerboneschi, Valentina; Mignogna, Marcello; Paoluzzi, Mauro; Ravaglia, Valentina; Chiumento, Costanza; Clemente, Stefania; Fusco, Vincenzo; Santini, Roberto; Stefanacci, Marco; Mangiacotti, Francesco P; Martini, Marco; Palloni, Tiziana; Schinaia, Giuseppe; Lazzari, Grazia; Silvano, Giovanni; Magrini, Stefano; Ricardi, Umberto; Santoni, Riccardo; Orecchia, Roberto
2016-09-01
Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 ((125)I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. (125)I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan-Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p < 0.0001) and V100 (p = 0.09) were correlated with BFFS, with V100 effect significantly different between patients at low risk and those at intermediate/high risk (p = 0.04). Short follow-up and lack of toxicity data represent the main limitations for a global evaluation of LDR-BT. This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome.
Tumor Localization Using Radio Frequency Implants
2006-09-01
from klystrons and other associated high - energy x-ray generating equipment in the surrounding area. The next logical concept is to use...BAT was developed to visualize the prostate organ before treatment.(34) This system requires that a technologist visually compare images received from ...distance from the transmitter. Since it is a thin wire loop, radiation can be delivered through it with minimal attenuation and
Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc
2013-11-15
Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then bemore » generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the computation time decrease with the number of points and that no effects were observed on the dosimetric indices when varying the number of sampling points and the number of iterations, they were respectively fixed to 2500 and to 100. The computation time to obtain ten complete treatments plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. However, 93% of the computation time is used by a research version of IPSA. For the breast, on average, the Radiation Therapy Oncology Group recommendations would be satisfied down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of V100, dose homogeneity index, and D90.Conclusions: The authors have devised a simple, fast and efficient method to optimize the number and position of catheters in interstitial HDR brachytherapy. The method was shown to be robust for both prostate and breast HDR brachytherapy. More importantly, the computation time of the algorithm is acceptable for clinical use. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning in HDR brachytherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kittel, Jeffrey A.; Reddy, Chandana A.; Smith, Kristin L.
Purpose/Objectives: To report long-term efficacy and toxicity for a single-institution cohort of patients treated with low-dose-rate prostate brachytherapy permanent implant (PI) monotherapy. Methods and Materials: From 1996 to 2007, 1989 patients with low-risk (61.3%), intermediate-risk (29.8%), high-intermediate-risk (4.5%), and high-risk prostate cancer (4.4%) were treated with PI and followed up prospectively in a registry. All patients were treated with {sup 125}I monotherapy to 144 Gy. Late toxicity was coded retrospectively according to a modified Common Terminology Criteria for Adverse Events 4.0 scale. The rates of biochemical relapse-free survival (bRFS), distant metastasis-free survival (DMFS), overall survival (OS), and prostate cancer–specific mortality (PCSM)more » were calculated. We identified factors associated with late grade ≥3 genitourinary (GU) and gastrointestinal (GI) toxicity, bRFS, DMFS, OS, PCSM, and incontinence. Results: The median age of the patients was 67 years, and the median overall and prostate-specific antigen follow-up times were 6.8 years and 5.8 years, respectively. The overall 5-year rates for bRFS, DMFS, OS, and PCSM were 91.9%, 97.8%, 93.7%, and 0.71%, respectively. The 10-year rates were 81.5%, 91.5%, 76.1%, and 2.5%, respectively. The overall rates of late grade ≥3 GU and GI toxicity were 7.6% and 0.8%, respectively. On multivariable analysis, age and prostate length were significantly associated with increased risk of late grade ≥3 GU toxicity. The risk of incontinence was highly correlated with both pre-PI and post-PI transurethral resection of the prostate. Conclusions: Prostate brachytherapy as monotherapy is an effective treatment for low-risk and low-intermediate-risk prostate cancer and appears promising as a treatment for high-intermediate-risk and high-risk prostate cancer. Significant long-term toxicities are rare when brachytherapy is performed as monotherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Y; Li, T; Yin, F
2015-06-15
Purpose: To investigate the choice of fixed margin or online adaptation when treating intermediate-risk prostate cancer including seminal vesicles (SV) using stereotactic body radiation therapy (SBRT). Methods: 9 prostate SBRT patients were retrospectively studied. All patients were implanted with fiducial markers in the prostate for daily localization and verification. Each patient had 5 pairs of pre-treatment and post-treatment cone-beam CT (CBCT) per protocol. SVs were contoured on planning CT and all CBCTs by one attending physician. Simultaneous integral boost (SIB) IMRT plans were developed to deliver 25Gy/5fx to the SV while delivering 37Gy/5fx to the prostate. A 3mm isotropic marginmore » was added to the prostate while a 5 mm isotropic margin was used for the SV. The planning CT was registered to daily pre-treatment and post-treatment CBCT based on fiducial markers in the prostate to mimic online prostate localization; and the SV on daily CBCT was transferred to the CT structure set after the prostates were aligned. Daily pre-treatment and post-treatment SV dose coverage and the organ-at-risk (OAR) sparing were evaluated for the SIB regimen. At least 95% of the SV need to receive the prescription dose (5Gy per fraction). Results: For the total of 90 daily SVs analyzed (ten CBCTs for each of nine patients), only 45 daily SVs (50%) were able to meet the coverage that 95% of the SV received 25Gy. The OAR sparing performance was acceptable for most of the dosimetric constraints in low-risk prostate SBRT protocol with only two exceptions in bladder V100 (cc). Conclusion: A fixed 5mm margin for SV is not sufficient to provide consistent daily dose coverage due to SV’s substantial inter- and intra-fractional motion relative to the prostate. This finding calls for innovative strategies in margin design as well as online treatment adaptation. This work is partially supported a master research grant from Varian Medical Systems.« less
Nd:YAG vitreolysis and pars plana vitrectomy: surgical treatment for vitreous floaters.
Delaney, Y M; Oyinloye, A; Benjamin, L
2002-01-01
To determine the efficacy of Nd:YAG vitreolysis and pars plana vitrectomy in the treatment of vitreous floaters. This is a single centre retrospective study of 31 patients (42 eyes) who underwent 54 procedures, Nd:YAG vitreolysis or pars plana vitrectomy, for the treatment of vitreous floaters between January 1992 and December 2000. Main outcome measures were percentage symptomatic improvement following treatment and incidence of post-operative complications. Statistical analysis was performed using the Fisher exact test. Posterior vitreous detachment was the primary cause of floaters in all 42 eyes with co-existing vitreous veils in three eyes and asteroid hyalosis in two eyes. Thirty-nine of 42 eyes received Nd:YAG vitreolysis. Thirty-eight percent found Nd:YAG vitreolysis moderately improved their symptoms while 61.5% found no improvement. After an average of 14.7 months follow-up no post-operative complications were recorded. Fifteen eyes underwent a pars plana vitrectomy, one with combined phacoemulsification and posterior chamber implantation and 11 following unsuccessful laser vitreolysis. Pars plana vitrectomy resulted in full resolution of symptoms in 93.3% of eyes. One patient developed a post-operative retinal detachment which was successfully treated leaving the patient with 6/5 VA. Patients' symptoms from vitreous floaters are often underestimated resulting in no intervention. This paper shows Nd:YAG vitreolysis to be a safe but only moderately effective primary treatment conferring clinical benefit in one third of patients. Pars plana vitrectomy, while offering superior results, should be reserved for patients who remain markedly symptomatic following vitreolysis, until future studies further clarify its role in the treatment of patients with floaters and posterior vitreous detachment.
Prostate-Specific Antigen: Nonspecific in Deceased Organ Donors.
Pabisiak, K; Ostrowski, M; Kram, A; Safranow, K; Myślak, M; Sieńko, J; Sulikowski, T; Ciechanowski, K
2016-06-01
Currently, there is no clear position regarding the donation of organs from donors with prostate carcinoma (CaP) in European countries, except Italy. The lengthening of life expectancy increases the probability of prostate cancer among potential organ donors. The concentration of prostate-specific antigen (PSA) >2 ng/mL at 60 years of age is related to the increasing possibility of identifying an advanced form of CaP. In recent years in Poland, the recommendation has been to determine tumor markers in potential donors. In the first year of the recommendation, 10% of potential male cadaveric donors were disqualified in West Pomerania, Poland, on the basis of elevated PSA levels (>10 ng/mL). To avoid reduction of the actual donor pool, each potential male donor reported to the center since January 2010 undergoes a routine histologic evaluation of the whole prostate, regardless of the PSA level, before organ implantation. In the study group (N = 52), histopathologic evaluation revealed 6 cases of CaP (12%). In CaP positive group Gleason score range from 2+2 to 3+4. In CaP donors PSA level have been noticed in range 1.79 ng/mL - 7.66 ng/mL. There was no correlation between histologically confirmed CaP and the PSA level. Copyright © 2016 Elsevier Inc. All rights reserved.
Multimodal imaging guided preclinical trials of vascular targeting in prostate cancer
Kalmuk, James; Folaron, Margaret; Buchinger, Julian; Pili, Roberto; Seshadri, Mukund
2015-01-01
The high mortality rate associated with castration-resistant prostate cancer (CRPC) underscores the need for improving therapeutic options for this patient population. The purpose of this study was to examine the potential of vascular targeting in prostate cancer. Experimental studies were carried out in subcutaneous and orthotopic Myc-CaP prostate tumors implanted into male FVB mice to examine the efficacy of a novel microtubule targeted vascular disrupting agent (VDA), EPC2407 (Crolibulin™). A non-invasive multimodality imaging approach based on magnetic resonance imaging (MRI), bioluminescence imaging (BLI), and ultrasound (US) was utilized to guide preclinical trial design and monitor tumor response to therapy. Imaging results were correlated with histopathologic assessment, tumor growth and survival analysis. Contrast-enhanced MRI revealed potent antivascular activity of EPC2407 against subcutaneous and orthotopic Myc-CaP tumors. Longitudinal BLI of Myc-CaP tumors expressing luciferase under the androgen response element (Myc-CaP/ARE-luc) revealed changes in AR signaling and reduction in intratumoral delivery of luciferin substrate following castration suggestive of reduced blood flow. This reduction in blood flow was validated by US and MRI. Combination treatment resulted in sustained vascular suppression, inhibition of tumor regrowth and conferred a survival benefit in both models. These results demonstrate the therapeutic potential of vascular targeting in combination with androgen deprivation against prostate cancer. PMID:26203773
NASA Astrophysics Data System (ADS)
Esteghamatian, Mehdi; Sarkar, Kripasindhu; Pautler, Stephen E.; Chen, Elvis C. S.; Peters, Terry M.
2012-02-01
Radical prostatectomy surgery (RP) is the gold standard for treatment of localized prostate cancer (PCa). Recently, emergence of minimally invasive techniques such as Laparoscopic Radical Prostatectomy (LRP) and Robot-Assisted Laparoscopic Radical Prostatectomy (RARP) has improved the outcomes for prostatectomy. However, it remains difficult for the surgeons to make informed decisions regarding resection margins and nerve sparing since the location of the tumor within the organ is not usually visible in a laparoscopic view. While MRI enables visualization of the salient structures and cancer foci, its efficacy in LRP is reduced unless it is fused into a stereoscopic view such that homologous structures overlap. Registration of the MRI image and peri-operative ultrasound image using a tracked probe can potentially be exploited to bring the pre-operative information into alignment with the patient coordinate system during the procedure. While doing so, prostate motion needs to be compensated in real-time to synchronize the stereoscopic view with the pre-operative MRI during the prostatectomy procedure. In this study, a point-based stereoscopic tracking technique is investigated to compensate for rigid prostate motion so that the same motion can be applied to the pre-operative images. This method benefits from stereoscopic tracking of the surface markers implanted over the surface of the prostate phantom. The average target registration error using this approach was 3.25+/-1.43mm.
Nicholson, Helen L; Al-Hakeem, Yasser; Maldonado, Javier J; Tse, Vincent
2017-07-01
The aim of this review is to examine all urethral strictures and stenoses subsequent to treatment for prostate cancer, including radical prostatectomy (RP), radiotherapy, high intensity focused ultrasound (HIFU) and cryotherapy. The overall majority respond to endoscopic treatment, including dilatation, direct visual internal urethrotomy (DVIU) or bladder neck incision (BNI). There are adjunct treatments to endoscopic management, including injections of corticosteroids and mitomycin C (MMC) and urethral stents, which remain controversial and are not currently mainstay of treatment. Recalcitrant strictures are most commonly managed with urethroplasty, while recalcitrant stenosis is relatively rare yet almost always associated with bothersome urinary incontinence, requiring bladder neck reconstruction and subsequent artificial urinary sphincter (AUS) implantation, or urinary diversion for the devastated outlet.
Nicholson, Helen L.; Al-Hakeem, Yasser; Maldonado, Javier J.
2017-01-01
The aim of this review is to examine all urethral strictures and stenoses subsequent to treatment for prostate cancer, including radical prostatectomy (RP), radiotherapy, high intensity focused ultrasound (HIFU) and cryotherapy. The overall majority respond to endoscopic treatment, including dilatation, direct visual internal urethrotomy (DVIU) or bladder neck incision (BNI). There are adjunct treatments to endoscopic management, including injections of corticosteroids and mitomycin C (MMC) and urethral stents, which remain controversial and are not currently mainstay of treatment. Recalcitrant strictures are most commonly managed with urethroplasty, while recalcitrant stenosis is relatively rare yet almost always associated with bothersome urinary incontinence, requiring bladder neck reconstruction and subsequent artificial urinary sphincter (AUS) implantation, or urinary diversion for the devastated outlet. PMID:28791228
Montecinos, Viviana P.; Godoy, Alejandro; Hinklin, Jennifer; Vethanayagam, R. Robert; Smith, Gary J.
2012-01-01
Characterization of the mechanism(s) of androgen-driven human angiogenesis could have significant implications for modeling new forms of anti-angiogenic therapies for CaP and for developing targeted adjuvant therapies to improve efficacy of androgen-deprivation therapy. However, models of angiogenesis by human endothelial cells localized within an intact human prostate tissue architecture are until now extremely limited. This report characterizes the burst of angiogenesis by endogenous human blood vessels in primary xenografts of fresh surgical specimens of benign prostate or prostate cancer (CaP) tissue that occurs between Days 6–14 after transplantation into SCID mice pre-implanted with testosterone pellets. The wave of human angiogenesis was preceded by androgen-mediated up-regulation of VEGF-A expression in the stromal compartment. The neo-vessel network anastomosed to the host mouse vascular system between Days 6–10 post-transplantation, the angiogenic response ceased by Day 15, and by Day 30 the vasculature had matured and stabilized, as indicated by a lack of leakage of serum components into the interstitial tissue space and by association of nascent endothelial cells with mural cells/pericytes. The angiogenic wave was concurrent with the appearance of a reactive stroma phenotype, as determined by staining for α-SMA, Vimentin, Tenascin, Calponin, Desmin and Masson's trichrome, but the reactive stroma phenotype appeared to be largely independent of androgen availability. Transplantation-induced angiogenesis by endogenous human endothelial cells present in primary xenografts of benign and malignant human prostate tissue was preceded by induction of androgen-driven expression of VEGF by the prostate stroma, and was concurrent with and the appearance of a reactive stroma phenotype. Androgen-modulated expression of VEGF-A appeared to be a causal regulator of angiogenesis, and possibly of stromal activation, in human prostate xenografts. PMID:22303438
Nguyen, Holly M; Vessella, Robert L; Morrissey, Colm; Brown, Lisha G; Coleman, Ilsa M; Higano, Celestia S; Mostaghel, Elahe A; Zhang, Xiaotun; True, Lawrence D; Lam, Hung-Ming; Roudier, Martine; Lange, Paul H; Nelson, Peter S; Corey, Eva
2017-05-01
Metastatic prostate cancer is a common and lethal disease for which there are no therapies that produce cures or long-term durable remissions. Clinically relevant preclinical models are needed to increase our understanding of biology of this malignancy and to evaluate new agents that might provide effective treatment. Our objective was to establish and characterize patient-derived xenografts (PDXs) from advanced prostate cancer (PC) for investigation of biology and evaluation of new treatment modalities. Samples of advanced PC obtained from primary prostate cancer obtained at surgery or from metastases collected at time of death were implanted into immunocompromised mice to establish PDXs. Established PDXs were propagated in vivo. Genomic, transcriptomic, and STR profiles were generated. Responses to androgen deprivation and docetaxel in vivo were characterized. We established multiple PDXs (LuCaP series), which represent the major genomic and phenotypic features of the disease in humans, including amplification of androgen receptor, PTEN deletion, TP53 deletion and mutation, RB1 loss, TMPRSS2-ERG rearrangements, SPOP mutation, hypermutation due to MSH2/MSH6 genomic aberrations, and BRCA2 loss. The PDX models also exhibit variation in intra-tumoral androgen levels. Our in vivo results show heterogeneity of response to androgen deprivation and docetaxel, standard therapies for advanced PC, similar to the responses of patients to these treatments. The LuCaP PDX series reflects the diverse molecular composition of human castration-resistant PC and allows for hypothesis-driven cause-and-effect studies of mechanisms underlying treatment response and resistance. Prostate 77: 654-671, 2017. © 2017 The Authors. The Prostate Published by Wiley Periodicals, Inc. © 2017 The Authors. The Prostate Published by Wiley Periodicals, Inc.
Prostate specific antigen bounce is related to overall survival in prostate brachytherapy.
Hinnen, Karel A; Monninkhof, Evelyn M; Battermann, Jan J; van Roermund, Joep G H; Frank, Steven J; van Vulpen, Marco
2012-02-01
To investigate the association between prostate specific antigen (PSA) bounce and disease outcome after prostate brachytherapy. We analyzed 975 patients treated with (125)I implantation monotherapy between 1992 and 2006. All patients had tumor Stage ≤ 2c, Gleason score ≤ 7 prostate cancer, a minimum follow-up of 2 years with at least four PSA measurements, and no biochemical failure in the first 2 years. Median follow-up was 6 years. Bounce was defined as a PSA elevation of +0.2 ng/mL with subsequent decrease to previous nadir. We used the Phoenix +2 ng/mL definition for biochemical failure. Additional endpoints were disease-specific and overall survival. Multivariate Cox regression analysis was performed to adjust for potential confounding factors. Bounce occurred in 32% of patients, with a median time to bounce of 1.6 years. More than 90% of bounces took place in the first 3 years after treatment and had disappeared within 2 years of onset. Ten-year freedom from biochemical failure, disease-specific survival, and overall survival rates were, respectively, 90%, 99%, and 88% for the bounce group and 70%, 93%, and 82% for the no-bounce group. Only 1 patient (0.3%) died of prostate cancer in the bounce group, compared with 40 patients (6.1%) in the no-bounce group. Adjusted for confounding, a 70% biochemical failure risk reduction was observed for patients experiencing a bounce (hazard ratio 0.31; 95% confidence interval 0.20-0.48). A PSA bounce after prostate brachytherapy is strongly related to better outcome in terms of biochemical failure, disease-specific survival, and overall survival. Copyright © 2012 Elsevier Inc. All rights reserved.
Photovaporisation prostatique au laser chez les patients à haut risque hémorragique
Bouabdallah, Zakaria; Kharbouchi, Amine; Colau, Alexandre; Cariou, Gerard
2013-01-01
Introduction Les patients sous traitement anticoagulant sont à risque élevé de saignement lors de la résection transurétrale de la prostate ou de l'adénomectomie par taille vésicale et ils se voient souvent récuser pour la chirurgie de l'hyperplasie bénigne de la prostate symptomatique. En Utilisant la photovaporisation de la prostate, les patients à haut risque peuvent subir en toute sécurité la chirurgie. Nous avons évalué l'innocuité et l'efficacité de la photovaporisation de la prostate (PVP) chez les patients sous anticoagulants en cours avec les dérivés de la coumarine, l'aspirine ou le clopidogrel, se plaignant de symptômes d'hypertrophie bénigne de la prostate. Méthodes Entre janvier 2009 et mai 2010, 47 hommes sous anticoagulation systémique ont subi une photovaporisation de la prostate. Les données ont été recueillies sur les caractéristiques démographiques, les comorbidités, les complications, la natrémie, l'hémoglobine, le débit urinaire maximal, le résidu post-mictionnel, l'IPSS et les complications. Résultats L'âge moyen était de 78 ans, le volume prostatique moyen était de 44g et le PSA était de 3.4ng/ml. Parmi les 10 patients (21.2%) étaient sous AVK, 27 (57.4%) étaient sous aspirine, 2 (4.2%) étaient sous clopidogrel, un sous fondaparinux et 6 (12.7%) étaient sous 2 anticoagulants ou plus. Le score ASA moyen était de 3. La durée moyenne de fonctionnement de l'appareil était de 38 minutes, l'énergie moyenne utilisée était de 200kJ. La durée moyenne d'hospitalisation était de 2 jours. Les complications survenant dans les 30 jours comprenaient une infection urinaire chez 5 patients (10.6%), une dysurie chez 4 patients et une hémorragie retardée chez 4 autres (8.5%). Un seul de ces patients a nécessité une transfusion sanguine et aucun patient n'a nécessité une réintervention. En 3 mois de suivi un seul patient a nécessité une incision du col vésical pour sclérose du col. Aucune incontinence ou sténose urétrale n'a été rapportée. Des améliorations significatives ont été notées dans l'IPSS, le débit urinaire maximal et le résidu post-mictionnel. Conclusion La PVP est caractérisé par d'excellentes propriétés hémostatiques et taux très faible de complications peropératoires même chez les patients sous 2 ou plusieurs agents anticoagulants. Sur la base de nos résultats péri-opératoires, nous recommandons la PVP comme traitement chirurgical de première intention chez les patients à haut risque de hémorragique souffrant de symptômes d'hypertrophie bénigne de la prostate. PMID:24570773
Echchaoui, Abdelmoughit; Benyachou, Malika; Hafidi, Jawad; Fathi, Nahed; Mohammadine, Elhamid; ELmazouz, Samir; Gharib, Nour-eddine; Abbassi, Abdellah
2014-01-01
Les malformations anorectales chez l'adulte sont des anomalies congénitales rares du tube digestif qui prédominent chez le sexe féminin. Notre étude porte sur deux observations de malformation anorectale basses vues et traitées au stade adulte par les 2 équipes (plasticiens et viscéralistes) à l'Hôpital Avicenne à Rabat. Il s'agit d'un homme de 24 ans avec une dyschésie anale l'autre cas est une femme de 18 ans avec une malformation anovulvaire Les caractéristiques cliniques combinées avec les imageries radiologiques (lavement baryté, et la manométrie anorectale) ont confirmé qu'il s'agit d'une malfomation anorectale basse. Les deux cas sont corrigés par une reconstruction sphinctérienne, réimplantation anale avec anoplastie périnéale. Les suites opératoires étaient simples, pas de souffrance cutanée ou nécrose, avec changement de pansement gras chaque jour. Le résultat fonctionnel (la continence) était favorable pour les 2 patients. La présentation des MAR à l’âge adulte est rare, d’étiologie mal connu, elles apparaissent selon le mode sporadique. Les caractéristiques cliniques, couplées à l'imagerie (lavement baryté, IRM pelvienne), l'endoscopie et la manométrie anorectale, permettent de confirmer le diagnostic et classer ces anomalies en 3 types: basses, intermédiaires, et hautes. Les formes basses sont traités d'emblée par une réimplantation anale et anoplastie périnéale simple tels nos deux cas, elles peuvent être traités dans certains cas par un abaissement anorectale associé à une plastie V-Y permettant ainsi un emplacement anatomique correct de l'anus; alors que les formes hautes ou intermédiaires relèvent d'une chirurgie complexe avec souvent une dérivation digestive transitoire. Contrairement aux autres formes, Les formes basses ont un pronostic fonctionnel favorable. PMID:25667689
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheung, J; Cunha, J; Sudhyadhom, A
Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from themore » MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research support and speaker honoraria from Accuray.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elzibak, A; Fatemi-Ardekani, A; Soliman, A
Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/more » TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best identify and delineate seeds and calcifications.« less
King, Benjamin L; Butler, Wayne M; Merrick, Gregory S; Kurko, Brian S; Reed, Joshua L; Murray, Brian C; Wallner, Kent E
2011-04-01
Real-time image guidance enables more accurate radiation therapy by tracking target movement. This study used transponder positions to monitor changes in prostate volume that may be a source of dosimetric and target inaccuracy. Twenty-four men with biopsy-proven T1c-T3a prostate cancer each had three electromagnetic transponders implanted transperineally. Their coordinates were recorded by the Calypso system, and the perimeter of the triangle formed by the transponders was used to calculate prostate volumes at sequential time points throughout the course of radiation therapy to a dose of 81 Gy in 1.8-Gy fractions. There was a significant decrease in mean prostate volume of 10.9% from the first to the final day of radiation therapy. The volume loss did not occur monotonically but increased in most patients (75%) during the first several weeks to a median maximum on Day 7. The volume increased by a mean of 6.1% before decreasing by a mean maximum difference of 18.4% to nadir (p < 0.001 for both increase and decrease). Glandular shrinkage was asymmetric, with the apex to right base dimension varying more than twice that of the lateral dimension. For all dimensions, the mean change was <0.5 cm. Real-time transponder positions indicated a volume increase during the initial days of radiation therapy and then significant and asymmetric shrinkage by the final day. Understanding and tracking volume fluctuations of the prostate during radiation therapy can help real-time imaging technology perform to its fullest potential. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, C; Palma, B; Qu, B
2014-06-01
Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned usingmore » a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from RaySearch laboratories; B Hardemark and E Hynning are employees of RaySearch.« less
Shilkrut, Mark; Merrick, Gregory S; McLaughlin, P William; Stenmark, Matthew H; Abu-Isa, Eyad; Vance, Sean M; Sandler, Howard M; Feng, Felix Y; Hamstra, Daniel A
2013-02-01
The objective of this study was to determine whether the addition of low-dose-rate brachytherapy or androgen-deprivation therapy (ADT) improves clinical outcome in patients with high-risk prostate cancer (HiRPCa) who received dose-escalated radiotherapy (RT). Between 1995 and 2010, 958 patients with HiRPCa were treated at Schiffler Cancer Center (n = 484) or at the University of Michigan (n = 474) by receiving either dose-escalated external-beam RT (EBRT) (n = 510; minimum prescription dose, 75 grays [Gy]; median dose, 78 Gy) or combined-modality RT (CMRT) consisting of (103) Pd implants (n = 369) or (125) I implants (n = 79) both with pelvic irradiation (median prescription dose, 45 Gy). The cumulative incidences of biochemical failure (BF) and prostate cancer-specific mortality (PCSM) were estimated by using the Kaplan-Meier method and Fine and Gray regression analysis. The median follow-up was 63.2 months (interquartile range, 35.4-99.0 months), and 250 patients were followed for >8 years. Compared with CMRT, patients who received EBRT had higher prostate-specific antigen levels, higher tumor classification, lower Gleason sum, and more frequent receipt of ADT for a longer duration. The 8-year incidence BF and PCSM among patients who received EBRT was 40% (standard error, 38%-44%) and 13% (standard error, 11%-15%) compared with 14% (standard error, 12%-16%; P < .0001) and 7% (standard error 6%-9%; P = .003) among patients who received CMRT. On multivariate analysis, the hazard ratios (HRs) for BF and PCSM were 0.35 (95% confidence interval [CI], 0.23-0.52; P < .0001) and 0.41 (95% CI, 0.23-0.75; P < .003), favoring CMRT. Increasing duration of ADT predicted decreased BF (P = .04) and PCSM (P = .001), which was greatest with long-term ADT (BF: HR, 0.33; P < .0001; 95% CI, 0.21-0.52; PCSM: HR, 0.30; P = .001; 95% CI, 0.15-0.6) even in the subgroup that received CMRT. In this retrospective comparison, both low-dose-rate brachytherapy boost and ADT were associated with decreased risks of BF and PCSM compared with EBRT. Copyright © 2012 American Cancer Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hueso-Gonzalez, F; Vijande, J; Ballester, F
Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43),more » ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).« less
Billi, B; Lesnoni, G; Audisio, P; Giuliano, M A; Rossi, T; Costi, E; Stirpe, M
1997-04-01
The authors report a case of posterior internal ophthalmomyiasis causing vitreous haemorrhage and retinal detachment after uncomplicated cataract extraction. The patient suffered an abrupt vitreous haemorrhage 9 days after ECCE and posterior chamber IOL implantation. After 2 months the haemorrhage did not clear up and a retinal detachment arose. The patient underwent encircling scleral buckle, pars plana vitrectomy and fluid-gas exchange. In course of intervention the surgeon removed from the vitreous chamber a 14-mm-long round worm subsequently identified as a dipterous larva of the Sarcophagidae family. The patient showed no sign of subretinal tracking or retinal breaks or holes. The sclerocorneal surgical wound seems the most likely site of entrance of the parasite, and this would then be the first reported case of myiasis with no RPE tracking.
Bertolo, Riccardo; Fiori, Cristian; Amparore, Daniele; Porpiglia, Francesco
2018-04-26
The purpose of the present systematic review is to offer a narrative synthesis of the available literature regarding the role of the temporary implantable nitinol device (TIND) (Medi-Tate®; Medi-Tate Ltd., Or Akiva, Israel) for the treatment of benign prostatic hyperplasia (BPH)-related lower urinary tract symptoms (LUTS), specifically focusing on the follow-up data. Current available evidences are limited in this topic. Sample size of patients available for analysis is small. Moreover, the duration of follow-up period is intermediate and longer follow-up is required. At the available 3 years follow-up, the TIND implantation is safe, effective, and well tolerated. The extended follow-up of the first and only available cohort of patients who underwent TIND for LUTS related to BPH corroborated previous literature findings. Further studies are required in order to assess the durability of TIND outcomes over a longer follow-up, to better define the indications of this approach, and to demonstrate the advantages of second-generation device over the first.
Edema and Seed Displacements Affect Intraoperative Permanent Prostate Brachytherapy Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westendorp, Hendrik, E-mail: r.westendorp@radiotherapiegroep.nl; Nuver, Tonnis T.; Department of Radiation Oncology, Radiotherapiegroep Behandellocatie Deventer, Deventer
Purpose: We sought to identify the intraoperative displacement patterns of seeds and to evaluate the correlation of intraoperative dosimetry with day 30 for permanent prostate brachytherapy. Methods and Materials: We analyzed the data from 699 patients. Intraoperative dosimetry was acquired using transrectal ultrasonography (TRUS) and C-arm cone beam computed tomography (CBCT). Intraoperative dosimetry (minimal dose to 40%-95% of the volume [D{sub 40}-D{sub 95}]) was compared with the day 30 dosimetry for both modalities. An additional edema-compensating comparison was performed for D{sub 90}. Stranded seeds were linked between TRUS and CBCT using an automatic and fast linking procedure. Displacement patterns weremore » analyzed for each seed implantation location. Results: On average, an intraoperative (TRUS to CBCT) D{sub 90} decline of 10.6% ± 7.4% was observed. Intraoperative CBCT D{sub 90} showed a greater correlation (R{sup 2} = 0.33) with respect to Day 30 than did TRUS (R{sup 2} = 0.17). Compensating for edema, the correlation increased to 0.41 for CBCT and 0.38 for TRUS. The mean absolute intraoperative seed displacement was 3.9 ± 2.0 mm. The largest seed displacements were observed near the rectal wall. The central and posterior seeds showed less caudal displacement than lateral and anterior seeds. Seeds that were implanted closer to the base showed more divergence than seeds close to the apex. Conclusions: Intraoperative CBCT D{sub 90} showed a greater correlation with the day 30 dosimetry than intraoperative TRUS. Edema seemed to cause most of the systematic difference between the intraoperative and day 30 dosimetry. Seeds near the rectal wall showed the most displacement, comparing TRUS and CBCT, probably because of TRUS probe–induced prostate deformation.« less
Anagnostopoulos, G; Baltas, D; Geretschlaeger, A; Martin, T; Papagiannis, P; Tselis, N; Zamboglou, N
2003-11-15
To evaluate the potential of in vivo thermoluminescence dosimetry to estimate the accuracy of dose delivery in conformal high-dose-rate brachytherapy of prostate cancer. A total of 50 LiF, TLD-100 cylindrical rods were calibrated in the dose range of interest and used as a batch for all fractions. Fourteen dosimeters for every treatment fraction were loaded in a plastic 4F catheter that was fixed in either one of the 6F needles implanted for treatment purposes or in an extra needle implanted after consulting with the patient. The 6F needles were placed either close to the urethra or in the vicinity of the median posterior wall of the prostate. Initial results are presented for 18 treatment fractions in 5 patients and compared to corresponding data calculated using the commercial treatment planning system used for the planning of the treatments based on CT images acquired postimplantation. The maximum observed mean difference between planned and delivered dose within a single treatment fraction was 8.57% +/- 2.61% (root mean square [RMS] errors from 4.03% to 9.73%). Corresponding values obtained after averaging results over all fractions of a patient were 6.88% +/- 4.93% (RMS errors from 4.82% to 7.32%). Experimental results of each fraction corresponding to the same patient point were found to agree within experimental uncertainties. Experimental results indicate that the proposed method is feasible for dose verification purposes and suggest that dose delivery in transperineal high-dose-rate brachytherapy after CT-based planning can be of acceptable accuracy.
Brunet-Benkhoucha, M; Verhaegen, F; Lassalle, S; Béliveau-Nadeau, D; Reniers, B; Donath, D; Taussky, D; Carrier, J-F
2008-07-01
To develop a tomosynthesis-based dose assessment procedure that can be performed after an I-125 prostate seed implantation, while the patient is still under anaesthesia on the treatment table. Our seed detection procedure involves the reconstruction of a volume of interest based on the backprojection of 7 seed-only binary images acquired over an angle of 60° with an isocentric imaging system. A binary seed-only volume is generated by a simple thresholding of the volume of interest. Seeds positions are extracted from this volume with a 3D connected component analysis and a statistical classifier that determines the number of seeds in each cluster of connected voxels. A graphical user interface (GUI) allows to visualize the result and to introduce corrections, if needed. A phantom and a clinical study (24 patients) were carried out to validate the technique. A phantom study demonstrated a very good localization accuracy of (0.4+/-0.4) mm when compared to CT-based reconstruction. This leads to dosimetric error on D90 and V100 of respectively 0.5% and 0.1%. In a patient study with an average of 56 seeds per implant, the automatic tomosynthesis-based reconstruction yields a detection rate of 96% of the seeds and less than 1.5% of false-positives. With the help of the GUI, the user can achieve a 100% detection rate in an average of 3 minutes. This technique would allow to identify possible underdosage and to correct it by potentially reimplanting additional seeds. A more uniform dose coverage could then be achieved in LDR prostate brachytherapy. © 2008 American Association of Physicists in Medicine.
Kim, Sun-Jin; Uehara, Hisanori; Karashima, Takashi; Shepherd, David L; Killion, Jerald J; Fidler, Isaiah J
2003-03-01
We determined whether blockade of the epidermal growth factor receptor (EGF-R) signaling pathway by oral administration of the EGF-R tyrosine kinase inhibitor (PKI 166) alone or in combination with injectable Taxol inhibits the growth of PC-3MM2 human prostate cancer cells in the bone of nude mice. Male nude mice implanted with PC-3MM2 cells in the tibia were treated with oral administrations of PKI 166 or PKI 166 plus injectable Taxol beginning 3 days after implantation. The incidence and size of bone tumors and destruction of bone were determined by digitalized radiography. Expression of epidermal growth factor (EGF), EGF-R, and activated EGF-R in tumor cells and tumor-associated endothelial cells was determined by immunohistochemistry. Oral administration of PKI 166 or PKI 166 plus injectable Taxol reduced the incidence and size of bone tumors and destruction of bone. Immunohistochemical analysis revealed that PC-3MM2 cells growing adjacent to the bone expressed high levels of EGF and activated EGF-R, whereas tumor cells in the adjacent musculature did not. Moreover, endothelial cells within the bone tumor lesions, but not in uninvolved bone or tumors in the muscle, expressed high levels of activated EGF-R. Treatment with PKI 166 and more so with PKI 166 plus Taxol significantly inhibited phosphorylation of EGF-R on tumor and endothelial cells and induced significant apoptosis and endothelial cells within tumor lesions. These data indicate that endothelial cells exposed to EGF produced by tumor cells express activated EGF-R and that targeting EGF-R can produce significant therapeutic effects against prostate cancer bone metastasis.
Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth
2016-01-01
To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Investigational procedures in benign prostatic hypertrophy.
Acquaye, Joseph; Borofsky, Michael S
2018-05-01
As benign prostatic hypertrophy (BPH) becomes a more common disease, there has been a dramatic rise in the number of investigational procedures being developed to manage it. We seek to present an overview of the most recently developed treatments and present clinical data related to application wherever available. As a greater number of treatments become available for BPH, improved diagnostic testing could prove beneficial in helping guide patient selection. Efforts are underway to identify serum biomarkers associated with BPH as well as new classifications strategies, specifically with MRI, to determine both the anatomy of BPH as well as its histologic distribution. Outpatient-based procedures for BPH currently being developed include the temporary implantable nitinol device as well as intraprostatic injections such as Botox and PRX302. Aquablation is a novel technique that uses robotically guided high-pressured saline to ablate prostate tissue. Early data suggests noninferiority compared with TURP. Finally, efforts are underway to apply robotics to BPH with the advent of a robotic transurethral platform being designed for prostate enucleation. Many new techniques are poised to be introduced to the BPH market over the coming years. The unique risk/benefit profiles as well as associated clinical outcomes of each will need to be studied in detail in order to help identify proper roles in the management of patients with symptomatic disease.
Transurethral light delivery for prostate photoacoustic imaging
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.
2015-03-01
Photoacoustic imaging has broad clinical potential to enhance prostate cancer detection and treatment, yet it is challenged by the lack of minimally invasive, deeply penetrating light delivery methods that provide sufficient visualization of targets (e.g., tumors, contrast agents, brachytherapy seeds). We constructed a side-firing fiber prototype for transurethral photoacoustic imaging of prostates with a dual-array (linear and curvilinear) transrectal ultrasound probe. A method to calculate the surface area and, thereby, estimate the laser fluence at this fiber tip was derived, validated, applied to various design parameters, and used as an input to three-dimensional Monte Carlo simulations. Brachytherapy seeds implanted in phantom, ex vivo, and in vivo canine prostates at radial distances of 5 to 30 mm from the urethra were imaged with the fiber prototype transmitting 1064 nm wavelength light with 2 to 8 mJ pulse energy. Prebeamformed images were displayed in real time at a rate of 3 to 5 frames per second to guide fiber placement and beamformed offline. A conventional delay-and-sum beamformer provided decreasing seed contrast (23 to 9 dB) with increasing urethra-to-target distance, while the short-lag spatial coherence beamformer provided improved and relatively constant seed contrast (28 to 32 dB) regardless of distance, thus improving multitarget visualization in single and combined curvilinear images acquired with the fiber rotating and the probe fixed. The proposed light delivery and beamforming methods promise to improve key prostate cancer detection and treatment strategies.
Cui, Can; Hanyu, Masayuki; Hatori, Akiko; Zhang, Yiding; Xie, Lin; Ohya, Tomoya; Fukada, Masami; Suzuki, Hisashi; Nagatsu, Kotaro; Jiang, Cuiping; Luo, Rui; Shao, Guoqiang; Zhang, Mingrong; Wang, Feng
2017-01-01
We radiolabeled a ligand, PSMA-617, of prostate-specific membrane antigen (PSMA) with copper-64 ( 64 Cu), to evaluate the metabolism, biodistribution, and potential of [ 64 Cu]PSMA-617 for PET imaging of prostate cancer. [ 64 Cu]PSMA-617 was synthesized by heating PSMA-617 with [ 64 Cu]CuCl 2 in buffer solution at 90°C for 5 min. In vitro uptake was determined in two cell lines of prostate cancer. In vivo regional distributions were determined in normal and tumor-bearing mice. High radiolabeling efficiency of 64 Cu for PSMA-617 yielded [ 64 Cu]PSMA-617 with >99% radiochemical purity. In vitro cellular uptake experiments demonstrated the specificity of [ 64 Cu]PSMA-617 for PSMA-positive LNCaP cells. Biodistribution observations of normal mice revealed high uptake of radioactivity in the kidney and liver. PET with [ 64 Cu]PSMA-617 visualized tumor areas implanted by PSMA-positive LNCaP cells in the mice. Two hours after the injection of [ 64 Cu]PSMA-617 into mice, a radiolabeled metabolite was observed in the blood, liver, urine, and LNCaP tumor tissues. [ 64 Cu]PSMA-617 was easily synthesized, and exhibited a favorable biodistribution in PSMA-positive tumors. Although this radioligand shows slow clearance for kidney and high liver uptake, change of its chelator moiety and easy radiolabeling may enable development of new 64 Cu or 67 Cu-labeled PSMA ligands for imaging and radiotherapy.
Cui, Can; Hanyu, Masayuki; Hatori, Akiko; Zhang, Yiding; Xie, Lin; Ohya, Tomoya; Fukada, Masami; Suzuki, Hisashi; Nagatsu, Kotaro; Jiang, Cuiping; Luo, Rui; Shao, Guoqiang; Zhang, Mingrong; Wang, Feng
2017-01-01
We radiolabeled a ligand, PSMA-617, of prostate-specific membrane antigen (PSMA) with copper-64 (64Cu), to evaluate the metabolism, biodistribution, and potential of [64Cu]PSMA-617 for PET imaging of prostate cancer. [64Cu]PSMA-617 was synthesized by heating PSMA-617 with [64Cu]CuCl2 in buffer solution at 90°C for 5 min. In vitro uptake was determined in two cell lines of prostate cancer. In vivo regional distributions were determined in normal and tumor-bearing mice. High radiolabeling efficiency of 64Cu for PSMA-617 yielded [64Cu]PSMA-617 with >99% radiochemical purity. In vitro cellular uptake experiments demonstrated the specificity of [64Cu]PSMA-617 for PSMA-positive LNCaP cells. Biodistribution observations of normal mice revealed high uptake of radioactivity in the kidney and liver. PET with [64Cu]PSMA-617 visualized tumor areas implanted by PSMA-positive LNCaP cells in the mice. Two hours after the injection of [64Cu]PSMA-617 into mice, a radiolabeled metabolite was observed in the blood, liver, urine, and LNCaP tumor tissues. [64Cu]PSMA-617 was easily synthesized, and exhibited a favorable biodistribution in PSMA-positive tumors. Although this radioligand shows slow clearance for kidney and high liver uptake, change of its chelator moiety and easy radiolabeling may enable development of new 64Cu or 67Cu-labeled PSMA ligands for imaging and radiotherapy. PMID:28533936
Establishing Prostate Cancer Patient Derived Xenografts: Lessons Learned From Older Studies
Russell, Pamela J; Russell, Peter; Rudduck, Christina; Tse, Brian W-C; Williams, Elizabeth D; Raghavan, Derek
2015-01-01
Background Understanding the progression of prostate cancer to androgen-independence/castrate resistance and development of preclinical testing models are important for developing new prostate cancer therapies. This report describes studies performed 30 years ago, which demonstrate utility and shortfalls of xenografting to preclinical modeling. Methods We subcutaneously implanted male nude mice with small prostate cancer fragments from transurethral resection of the prostate (TURP) from 29 patients. Successful xenografts were passaged into new host mice. They were characterized using histology, immunohistochemistry for marker expression, flow cytometry for ploidy status, and in some cases by electron microscopy and response to testosterone. Two xenografts were karyotyped by G-banding. Results Tissues from 3/29 donors (10%) gave rise to xenografts that were successfully serially passaged in vivo. Two, (UCRU-PR-1, which subsequently was replaced by a mouse fibrosarcoma, and UCRU-PR-2, which combined epithelial and neuroendocrine features) have been described. UCRU-PR-4 line was a poorly differentiated prostatic adenocarcinoma derived from a patient who had undergone estrogen therapy and bilateral castration after his cancer relapsed. Histologically, this comprised diffusely infiltrating small acinar cell carcinoma with more solid aggregates of poorly differentiated adenocarcinoma. The xenografted line showed histology consistent with a poorly differentiated adenocarcinoma and stained positively for prostatic acid phosphatase (PAcP), epithelial membrane antigen (EMA) and the cytokeratin cocktail, CAM5.2, with weak staining for prostate specific antigen (PSA). The line failed to grow in female nude mice. Castration of three male nude mice after xenograft establishment resulted in cessation of growth in one, growth regression in another and transient growth in another, suggesting that some cells had retained androgen sensitivity. The karyotype (from passage 1) was 43–46, XY, dic(1;12)(p11;p11), der(3)t(3:?5)(q13;q13), -5, inv(7)(p15q35) x2, +add(7)(p13), add(8)(p22), add(11)(p14), add(13)(p11), add(20)(p12), -22, +r4[cp8]. Conclusions Xenografts provide a clinically relevant model of prostate cancer, although establishing serially transplantable prostate cancer patient derived xenografts is challenging and requires rigorous characterization and high quality starting material. Xenografting from advanced prostate cancer is more likely to succeed, as xenografting from well differentiated, localized disease has not been achieved in our experience. Strong translational correlations can be demonstrated between the clinical disease state and the xenograft model. Prostate 75: 628–636, 2015. © The Authors. The Prostate published by Wiley Periodicals, Inc. PMID:25560784
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rezaeian, N Hassan; Chi, Y; Tian, Z
Purpose: A clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer is undergoing at our institution. In addition to escalating dose to the prostate, we have increased dose to intra-prostatic lesions. Intra-fractional prostate motion deteriorates well planned radiation dose, especially for the small intra-prostatic lesions. To solve this problem, we have developed a motion tracking and 4D dose-reconstruction system to facilitate adaptive re-planning. Methods: Patients in the clinical trial were treated with VMAT using four arcs and 10 FFF beam. KV triggered x-ray projections were taken every 3 sec during delivery to acquire 2D projections of 3Dmore » anatomy at the direction orthogonal to the therapeutic beam. Each patient had three implanted prostate markers. Our developed system first determined 2D projection locations of these markers and then 3D prostate translation and rotation via 2D/3D registration of the markers. Using delivery log files, our GPU-based Monte Carlo tool (goMC) reconstructed dose corresponding to each triggered image. The calculated 4D dose distributions were further aggregated to yield the delivered dose. Results: We first tested each module in our system. MC dose engine were commissioned to our treatment planning system with dose difference of <0.5%. For motion tracking, 1789 kV projections from 7 patients were acquired. The 2D marker location error was <1 mm. For 3D motion tracking, root mean square (RMS) errors along LR, AP, and CC directions were 0.26mm, 0.36mm, and 0.01mm respectively in simulation studies and 1.99mm, 1.37mm, and 0.22mm in phantom studies. We also tested the entire system workflow. Our system was able to reconstruct delivered dose. Conclusion: We have developed a functional intra-fractional motion tracking and 4D dose re-construction system to support our clinical trial on adaptive high-risk prostate cancer SBRT. Comprehensive evaluations have shown the capability and accuracy of our system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neustadter, David, E-mail: david.n@navotek.co; Tune, Michal; Zaretsky, Asaph
Purpose: To analyze the stability, visibility, and histology of a novel implantable soft-tissue marker (nonradioactive and radioactive) implanted in dog prostate and rabbit liver. Methods and Materials: A total of 34 nonradioactive and 35 radioactive markers were implanted in 1 dog and 16 rabbits. Stability was assessed by measuring intermarker distance (IMD) variation relative to IMDs at implantation. The IMDs were measured weekly for 4 months in the dog and biweekly for 2-4 weeks in the rabbits. Ultrasound and X-ray imaging were performed on all subjects. Computed tomography and MRI were performed on the dog. Histologic analysis was performed onmore » the rabbits after 2 or 4 months. Results: A total of 139 measurements had a mean ({+-} SD) absolute IMD variation of 1.1 {+-} 1.1 mm. These IMD variations are consistent with those reported in the literature as due to random organ deformation. The markers were visible, identifiable, and induced minimal or no image artifacts in all tested imaging modalities. Histologic analysis revealed that all pathologic changes were highly localized and not expected to be clinically significant. Conclusions: The markers were stable from the time of implantation. The markers were found to be compatible with all common medical imaging modalities. The markers caused no significant histologic effects. With respect to marker stability, visibility, and histologic analysis these implanted fiducials are appropriate for soft-tissue target positioning in radiotherapy.« less
Corrosion analysis of NiCu and PdCo thermal seed alloys used as interstitial hyperthermia implants.
Paulus, J A; Parida, G R; Tucker, R D; Park, J B
1997-12-01
Ferromagnetic materials with low Curie temperatures are being investigated for use as interstitial implants for fractionated hyperthermia treatment of prostatic disease. Previous investigations of the system have utilized alloys, such as NiCu, with inadequate corrosion resistance, requiring the use of catheters for removal of the implants following treatment or inert surface coatings which may interfere with thermal characteristics of the implants. We are evaluating a palladium-cobalt (PdCo) binary alloy which is very similar to high palladium alloys used in dentistry. Electrochemical corrosion tests and immersion tests at 37 degrees C for both NiCu and PdCo alloy samples in mammalian Ringer's solution were performed. Long-term corrosion rates are 5.8 x 10(-5) microm per year (NiCu) and 7.7 x 10(-8) microm per year (PdCo) from average immersion test results, indicating higher corrosion resistance of PdCo (P < 0.02); immersion corrosion rates were much lower than initial corrosion rates found electrochemically. Both alloys had significantly lower corrosion rates than standard surgical implant rates of 0.04 microm per year (P < 0.001 for both alloys). Scanning electron microscopy illustrates changes in the NiCu alloy surface due to pitting corrosion; no difference is observed for PdCo. The data indicate that the PdCo alloy may be suitable as a long-term implant for use in fractionated hyperthermia.
Machine Perception (La Perception de l’Environment par Senseurs Automatiques).
1992-08-01
France, January 25-27, 1984, Lectures. Volumes 1 & 2 Reconnaissance des formes et intelligence artificielle ; Congres Francais, 4th, Paris, France, January...capteurs intelligents intkgris - traitement cellulaire et neuronal - operateurs visuels de base -implantation analogique vs digitale A smart retina is a...I’I riscc Li li mttlL’ dliitrlt ITTIC dies % eiicule it dsitisitl Ct Lie"IIN10%Ct ,v,,temcs intelligents dfaidc a [a perception de lai situatiotn. O
Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio
2015-01-01
Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590
Wallner, K; Roy, J; Harrison, L
1996-10-01
To determine the incidence of postimplant infection in patients who are not given prophylactic antibiotics (ATBs). One hundred thirty-one patients had computerized tomography (CT)-planned transperineal 125I implantation of the prostate from 1988 through 1995. One hundred fourteen of the patients did not receive prophylactic ATBs, 19 of whom required postimplant Foley catheter drainage for 1 day or more for acute urinary retention. The incidence of postimplant febrile episodes within 2 weeks of surgery among the patients who had not received prophylactic ATBs was 2 of 114 (2%). One of the two patients who developed postimplantation febrile episodes was treated successfully with ATBs as an outpatient. The second patient, who had a history of chronic lymphocytic leukemia (CLL) and immune suppression, developed E. coli sepsis and required intravenous antibiotics. Of 17 patients who received prophylactic ATBs, none had a postoperative febrile episode. We continue to refrain from routinely prescribing prophylactic ATBs unless there is some compelling circumstance including rheumatic heart disease, prosthetic devices, immune compromise, or a previous history of prostatitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, Christopher A.; Cesaretti, Jamie A.; Stone, Nelson N.
2006-10-01
Purpose: We report on the follow-up of 24 patients with a prior history of inflammatory bowel disease (IBD) treated with brachytherapy for early-stage prostate cancer. Methods and Materials: Twenty-four patients with a history of inflammatory bowel disease (17 with ulcerative colitis (UC), 7 with Crohn's disease [CD]) underwent prostate brachytherapy between 1992 and 2004. Fifteen patients were treated with I-125 implantation and 6 patients were treated with Pd-103 alone or in combination with 45 Gy external beam radiation. Charts were reviewed for all patients, and all living patients were contacted by phone. National Cancer Institute common toxicity scores for proctitismore » were assigned to all patients. Actuarial risk of late toxicity was calculated by the Kaplan-Meier method. Statistical analysis was performed using SPSS software. Follow-up ranged from 3 to 126 months (median, 48.5 months; mean, 56.8 months). Results: None of the patients experienced Grade 3 or 4 rectal toxicity. Four patients experienced Grade 2 late rectal toxicity. The 5-year actuarial freedom from developing late Grade 2 rectal toxicity was 81%. At a median follow-up of 48.5 months, 23 patients were alive and had no evidence of disease with a median prostate-specific antigen for the sample of 0.1 ng/mL (range, <0.05-0.88 ng/mL). One patient died of other causes unrelated to his prostate cancer. Conclusions: Prostate brachytherapy is well tolerated in patients with a history of controlled IBD. Therefore, brachytherapy should be considered a viable therapeutic option in this patient population.« less
de Amorim Ribeiro, Ilma Cely; da Costa, Carlos Alberto Soares; da Silva, Vivian Alves Pereira; Côrrea, Lanna Beatriz Neves Silva; Boaventura, Gilson Teles; Chagas, Mauricio Alves
2017-04-01
This study aimed to quantitatively and qualitatively evaluate the effects of a flaxseed-based diet on the histoarchitecture of the prostate of normal Wistar rats and of rats with induced BPH. The study included four experimental groups of ten animals each: casein control group (CCG), who were fed a casein-based diet; flaxseed control group (FCG), who were fed a flaxseed-based diet; hyperplasia-induced casein group (HICG), who were fed a casein-based diet; and hyperplasia-induced flaxseed group (HIFG), who were fed a flaxseed-based diet. Hyperplasia was induced by the subcutaneous implantation of silicone pellets containing testosterone propionate. After 20 weeks, the rats were euthanized and their prostate fixed in buffered formalin. Tissue sections were stained with HE, picrosirius red and immunostained for nuclear antigen p63. Histomorphometric analysis evaluated the epithelial thickness, epithelial area, individual luminal area, and total area of prostatic alveoli. The mean epithelial thickness obtained for HIFG and HICG was 16.52 ± 1.65 and 20.58 ± 2.86 µm, respectively. The mean epithelial thickness in HICG was greater than that in the other groups tested. HIFG had a smaller epithelial thickness and lower percentage of papillary projections in the prostatic alveoli. No significant difference was observed between CCG and FCG. The total area and mean alveolar area showed no significant differences between the groups. The number of cells immunostained for p63 was not significantly different between the groups evaluated. These results suggest that flaxseed has a protective effect on the prostate epithelium in BPH-induced animals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uesugi, Tatsuya; Saika, Takashi, E-mail: saika@cc.okayama-u.ac.jp; Edamura, Kohei
2012-02-01
Purpose: To reveal a predictive factor for biochemical recurrence (BCR) after permanent prostate brachytherapy (PPB) using iodine-125 seed implantation in patients with localized prostate cancer classified as low or intermediate risk based on National Comprehensive Cancer Network (NCCN) guidelines. Methods and Materials: From January 2004 to December 2009, 414 consecutive Japanese patients with clinically localized prostate cancer classified as low or intermediate risk based on the NCCN guidelines were treated with PPB. The clinical factors including pathological data reviewed by a central pathologist and follow-up data were prospectively collected. Kaplan-Meier and Cox regression analyses were used to assess the factorsmore » associated with BCR. Results: Median follow-up was 36.5 months. The 2-, 3-, 4-, and 5-year BCR-free rates using the Phoenix definition were 98.3%, 96.0%, 91.6%, and 87.0%, respectively. On univariate analysis, the Gleason score, especially primary Gleason grade 4 in biopsy specimens, was a strong predicting factor (p < 0.0001), while age, initial prostate-specific antigen (PSA) level, T stage, and minimal dose delivered to 90% of the prostate volume (D90) were insignificant. Multivariate analysis indicated that a primary Gleason grade 4 was the most powerful prognostic factor associated with BCR (hazard ratio = 6.576, 95% confidence interval, 2.597-16.468, p < 0.0001). Conclusions: A primary Gleason grade 4 carried a worse BCR prognosis than the primary grade 3 in patients treated with PPB. Therefore, the indication for PPB in patients with a Gleason sum of 4 + 3 deserves careful and thoughtful consideration.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fletcher, Sophie G.; Mills, Stacey E.; Smolkin, Mark E.
2006-11-15
Purpose: Few studies critically compare current radiotherapy techniques to surgery for patients with locally advanced prostate cancer, despite an urgent need to determine which approach offers superior cancer control. Our objective was to compare rates of biochemical relapse-free survival (BFS) and surrogates of disease specific survival among men with high risk adenocarcinoma of the prostate as a function of treatment modality. Methods and Materials: Retrospective data from 409 men with prostate-specific antigen (PSA) {>=}10 or Gleason 7-10 or Stage {>=}T2b cancer treated uniformly at one university between March 1988 and December 2000 were analyzed. Patients had undergone radical prostatectomy (RP),more » brachytherapy implant alone (BTM), or external beam radiotherapy with brachytherapy boost with short-term neoadjuvant and adjuvant androgen deprivation therapy (BTC). From the total study population a 1:1 matched-cohort analysis (208 patients matched via prostate-specific antigen, Gleason score) comparing RP with BTC was performed as well. Results: Estimated 4-year BFS rates were superior for patients treated with BTC (BTC 72%, BTM 25%, RP 53%; p < 0.001). Matched analysis of BTC vs. RP confirmed these results (BTC 73%, BTM 55%; p = 0.010). Relative risk (RR) of biochemical relapse for BTM and BTC compared with RP were 2.92 (1.95-4.36) and 0.56 (0.36-0.87) (p < 0.001, p = 0.010). RR for BTC from the matched cohort analysis was 0.44 (0.26-0.74; p = 0.002). Conclusions: High-risk prostate cancer patients receiving multimodality radiation therapy (BTC) display apparently superior BFS compared with those receiving surgery (RP) or brachytherapy alone (BTM)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, Chris; Herman, Michael G.; Davis, Brian J.
2008-01-01
Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the fourmore » daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayyas, Essa, E-mail: emayyas1@hfhs.org, E-mail: ortonc@comcast.net; Kim, Jinkoo; Kumar, Sanath
2014-09-15
Purpose: Prostate deformation is assumed to be a secondary correction and is typically ignored in the planning target volume (PTV) margin calculations. This assumption needs to be tested, especially when planning margins are reduced with daily image-guidance. In this study, deformation characteristics of the prostate and seminal vesicles were determined, and the dosimetric impact on treatment plans with different PTV margins was investigated. Methods: Ten prostate cancer patients were retrospectively selected for the study, each with three fiducial markers implanted in the prostate. Two hundred CBCT images were registered to respective planning CT images using a B-spline-based deformable image registrationmore » (DIR) software. A manual bony anatomy-based match was first applied based on the alignment of the pelvic bones and fiducial landmarks. DIR was then performed. For each registration, deformation vector fields (DVFs) of the prostate and seminal vesicles (SVs) were quantified using deformation-volume histograms. In addition, prostate rotation was evaluated and compared with prostate deformation. For a patient demonstrating small and large prostate deformations, target coverage degradation was analyzed in each of three treatment plans with PTV margins of 10 mm (6 mm at the prostate/rectum interface), as well as 5, and 3 mm uniformly. Results: Deformation of the prostate was most significant in the anterior direction. Maximum prostate deformation of greater than 10, 5, and 3 mm occurred in 1%, 17%, and 76% of the cases, respectively. Based on DVF-histograms, DVF magnitudes greater than 5 and 3 mm occurred in 2% and 27% of the cases, respectively. Deformation of the SVs was most significant in the posterior direction, and it was greater than 5 and 3 mm in 7.5% and 44.9% of the cases, respectively. Prostate deformation was found to be poorly correlated with rotation. Fifty percent of the cases showed rotation with negligible deformation and 7% of the cases showed significant deformation with minimal rotation (<3°). Average differences in the D{sub 95} dose to the prostate + SVs between the planning CT and CBCT images was 0.4% ± 0.5%, 3.0% ± 2.8%, and 6.6% ± 6.1%, respectively, for the plans with 10/6, 5, and 3 mm margins. For the case with both a large degree of prostate deformation (≈10% of the prostate volume) and rotation (≈8°), D{sub 95} was reduced by 0.5% ± 0.1%, 6.8% ± 0.6%, and 20.9% ± 1.6% for 10/6, 5, and 3 mm margin plans, respectively. For the case with large prostate deformation but negligible rotation (<1°), D{sub 95} was reduced by 0.4 ± 0.3, 3.9 ± 1.0, and 11.5 ± 2.5 for 10/6, 5, and 3 mm margin plans, respectively. Conclusions: Prostate deformation over a course of fractionated prostate radiotherapy may not be insignificant and may need to be accounted for in the planning margin design. A consequence of these results is that use of highly reduced planning margins must be viewed with caution.« less
SU-E-T-279: Realization of Three-Dimensional Conformal Dose Planning in Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Z; Jiang, S; Yang, Z
2014-06-01
Purpose: Successful clinical treatment in prostate brachytherapy is largely dependent on the effectiveness of pre-surgery dose planning. Conventional dose planning method could hardly arrive at a satisfy result. In this abstract, a three-dimensional conformal localized dose planning method is put forward to ensure the accuracy and effectiveness of pre-implantation dose planning. Methods: Using Monte Carlo method, the pre-calculated 3-D dose map for single source is obtained. As for multiple seeds dose distribution, the maps are combined linearly to acquire the 3-D distribution. The 3-D dose distribution is exhibited in the form of isodose surface together with reconstructed 3-D organs groupmore » real-timely. Then it is possible to observe the dose exposure to target volume and normal tissues intuitively, thus achieving maximum dose irradiation to treatment target and minimum healthy tissues damage. In addition, the exfoliation display of different isodose surfaces can be realized applying multi-values contour extraction algorithm based on voxels. The needles could be displayed in the system by tracking the position of the implanted seeds in real time to conduct block research in optimizing insertion trajectory. Results: This study extends dose planning from two-dimensional to three-dimensional, realizing the three-dimensional conformal irradiation, which could eliminate the limitations of 2-D images and two-dimensional dose planning. A software platform is developed using VC++ and Visualization Toolkit (VTK) to perform dose planning. The 3-D model reconstruction time is within three seconds (on a Intel Core i5 PC). Block research could be conducted to avoid inaccurate insertion into sensitive organs or internal obstructions. Experiments on eight prostate cancer cases prove that this study could make the dose planning results more reasonable. Conclusion: The three-dimensional conformal dose planning method could improve the rationality of dose planning by safely reducing the large target margin and avoiding dose dead zones for prostate cancer treatment. 1) National Natural Science Foundation of People's Republic of China (No. 51175373); 2) New Century Educational Talents Plan of Chinese Education Ministry (NCET-10-0625); 3) Scientific and Technological Major Project, Tianjin (No. 12ZCDZSY10600)« less
NASA Astrophysics Data System (ADS)
McGeachy, Philip David
Over 50% of cancer patients require radiation therapy (RT). RT is an optimization problem requiring maximization of the radiation damage to the tumor while minimizing the harm to the healthy tissues. This dissertation focuses on two main RT optimization problems: 1) brachytherapy and 2) intensity modulated radiation therapy (IMRT). The brachytherapy research involved solving a non-convex optimization problem by creating an open-source genetic algorithm optimizer to determine the optimal radioactive seed distribution for a given set of patient volumes and constraints, both dosimetric- and implant-based. The optimizer was tested for a set of 45 prostate brachytherapy patients. While all solutions met the clinical standards, they also benchmarked favorably with those generated by a standard commercial solver. Compared to its compatriot, the salient features of the generated solutions were: slightly reduced prostate coverage, lower dose to the urethra and rectum, and a smaller number of needles required for an implant. Historically, IMRT requires modulation of fluence while keeping the photon beam energy fixed. The IMRT-related investigation in this thesis aimed at broadening the solution space by varying photon energy. The problem therefore involved simultaneous optimization of photon beamlet energy and fluence, denoted by XMRT. Formulating the problem as convex, linear programming was applied to obtain solutions for optimal energy-dependent fluences, while achieving all clinical objectives and constraints imposed. Dosimetric advantages of XMRT over single-energy IMRT in the improved sparing of organs at risk (OARs) was demonstrated in simplified phantom studies. The XMRT algorithm was improved to include clinical dose-volume constraints and clinical studies for prostate and head and neck cancer patients were investigated. Compared to IMRT, XMRT provided improved dosimetric benefit in the prostate case, particularly within intermediate- to low-dose regions (≤ 40 Gy) for OARs. For head and neck cases, XMRT solutions showed no significant disadvantage or advantage over IMRT. The deliverability concerns for the fluence maps generated from XMRT were addressed by incorporating smoothing constraints during the optimization and through successful generation of treatment machine files. Further research is needed to explore the full potential of the XMRT approach to RT.
Saad, Akram; Goldstein, Jeffrey; Lawrence, Yaacov Richard; Weiss, Ilana; Saad, Rasha; Spieler, Benjamin; Symon, Zvi
2015-12-01
The purpose is to describe the method, safety and efficacy of transperineal gold seed placement for image-guided radiation therapy. An ethics committee approved database was used to review records of consecutive patients from October 2008 through December 2013, who underwent transperineal implantation of three gold markers into the prostate using staged local anaesthesia and transrectal ultrasound. Seeds were counted on radiographs from CT simulation, first treatment and last treatment. Retention and use of at least three markers for kV/kV matching was considered a successful implant. A visual analogue scale (VAS) pain assessment was performed. SAS was used for data analysis. Fiducial marker placement was successful for kV/kV matching in 556/581 patients (95.7%). The procedure was aborted due to pain in two patients. Additional sedation during the procedure was required in two patients. Complications include urinary infections (2 patients, <0.5%) and transient haematuria (2 patients, <0.5%). There were no recorded calls requesting additional pain medication or delays in radiation due to complications. The number of seeds identified at simulation: 4 (2 patients), 3 (554 patients), 2 (21 patients), 1 (1 patient), 0 (1 patient). One patient with three seeds and two patients with <2 seeds had cone beam CT instead of kV/kV imaging for image guidance. No seeds were lost after simulation. The mean visual analogue pain score associated with transperineal gold seed insertion met patients' expectations (respectively 4.1 vs. 4.4 P = 0.19). Outpatient transperineal insertion of fiducials avoids the rectum, is effective, convenient, well tolerated and has few side effects.
Establishing prostate cancer patient derived xenografts: lessons learned from older studies.
Russell, Pamela J; Russell, Peter; Rudduck, Christina; Tse, Brian W C; Williams, Elizabeth D; Raghavan, Derek
2015-05-01
Understanding the progression of prostate cancer to androgen-independence/castrate resistance and development of preclinical testing models are important for developing new prostate cancer therapies. This report describes studies performed 30 years ago, which demonstrate utility and shortfalls of xenografting to preclinical modeling. We subcutaneously implanted male nude mice with small prostate cancer fragments from transurethral resection of the prostate (TURP) from 29 patients. Successful xenografts were passaged into new host mice. They were characterized using histology, immunohistochemistry for marker expression, flow cytometry for ploidy status, and in some cases by electron microscopy and response to testosterone. Two xenografts were karyotyped by G-banding. Tissues from 3/29 donors (10%) gave rise to xenografts that were successfully serially passaged in vivo. Two, (UCRU-PR-1, which subsequently was replaced by a mouse fibrosarcoma, and UCRU-PR-2, which combined epithelial and neuroendocrine features) have been described. UCRU-PR-4 line was a poorly differentiated prostatic adenocarcinoma derived from a patient who had undergone estrogen therapy and bilateral castration after his cancer relapsed. Histologically, this comprised diffusely infiltrating small acinar cell carcinoma with more solid aggregates of poorly differentiated adenocarcinoma. The xenografted line showed histology consistent with a poorly differentiated adenocarcinoma and stained positively for prostatic acid phosphatase (PAcP), epithelial membrane antigen (EMA) and the cytokeratin cocktail, CAM5.2, with weak staining for prostate specific antigen (PSA). The line failed to grow in female nude mice. Castration of three male nude mice after xenograft establishment resulted in cessation of growth in one, growth regression in another and transient growth in another, suggesting that some cells had retained androgen sensitivity. The karyotype (from passage 1) was 43-46, XY, dic(1;12)(p11;p11), der(3)t(3:?5)(q13;q13), -5, inv(7)(p15q35) x2, +add(7)(p13), add(8)(p22), add(11)(p14), add(13)(p11), add(20)(p12), -22, +r4[cp8]. Xenografts provide a clinically relevant model of prostate cancer, although establishing serially transplantable prostate cancer patient derived xenografts is challenging and requires rigorous characterization and high quality starting material. Xenografting from advanced prostate cancer is more likely to succeed, as xenografting from well differentiated, localized disease has not been achieved in our experience. Strong translational correlations can be demonstrated between the clinical disease state and the xenograft model. © 2015 The Authors. The Prostate published by Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chi, Y; Rezaeian, N Hassan; Hannan, R
Purpose: Intra-fractional prostate motion leads uncertainty on delivered dose in radiotherapy and may cause significant dose deviation from the planned dose distribution. This is especially a concern in scenarios with a high dose per fraction and hence a long delivery time, e.g. stereotactic body radiotherapy. Knowledge about intra-fractional prostate motion is valuable to address this problem, e.g. by reconstructing delivered dose and performing adaptation. This study proposes a new approach to determine intra-fractional prostate motion in VMAT via 2D/3D maker registration. Methods: At our institution, each patient has three markers implanted in the prostate. During treatment delivery, kV triggered imagesmore » were taken every three seconds to acquire 2D projection of 3D anatomy at the direction orthogonal to the therapeutic beam. Projected marker locations were identified on each projection image using template matching with geometric constraints. 3D prostate translation and rotation for each triggered image were obtained by solving an optimization problem, such that the calculated marker locations match the measured ones. Inter-image motion smoothness was employed as a constraint. We tested this method in simulation studies with five realistic prostate motion trajectories acquired via Calypso and in real phantom experiments. Results: For the simulation case, the motion range for these patients was 0.5∼6.0 mm. Root mean square (RMS) error of calculated motion along left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) directions were 0.26mm, 0.36mm, and 0.016mm, respectively. The motion range in the phantom study along LR, AP, and CC directions were 15mm, 20mm and 10mm. The mean RMS errors along these directions were 1.99mm, 1.37mm and 0.22mm. Conclusion: A new prostate motion tracking algorithm based on kV triggered images has been developed and validated. Clinically acceptable accuracy has been achieved.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, Jin Aun; Institute of Medical Physics, School of Physics, University of Sydney, New South Wales; Booth, Jeremy T.
2012-12-01
Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiringmore » kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.« less
Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J
2015-03-01
To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.
2015-03-01
Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less
Ray, Alistair; Morgan, Helen; Wilkes, Antony; Carter, Kimberley; Carolan-Rees, Grace
2016-10-01
As part of its Medical Technologies Evaluation Programme (MTEP), the National Institute for Health and Care Excellence (NICE) invited Neotract (manufacturer) to submit clinical and economic evidence for their prostatic urethral lift device, Urolift, for the relief of lower urinary tract symptoms secondary to benign prostatic hyperplasia (LUTS BPH). The Urolift System uses implants to retract the prostatic lobe away from the urethral lumen. The clinical evidence used in the manufacturer's submission shows that Urolift is effective for the treatment of BPH. Urolift delivers a weighted mean International Prostate Symptom Score (IPSS) improvement of between 9.22 and 11.82 points. These Urolift improvements are greater than a published 'marked improvement' in IPSS score of 8.80. Comparison with randomised controlled trials (RCTs) of TURP (Transurethral Resection of Prostate) and HoLEP (Holmium Laser Enucleation of Prostate) show that Urolift does not yield better clinical outcomes from baseline compared to TURP and HoLEP in terms of IPSS, QoL (Quality of Life) and Qmax (maximum urinary flow). However, Urolift appears to have the advantage in terms of minimal and mild complications, and this may be of interest to patients and urologists. The economic case for Urolift was made using a very detailed and thorough de novo cost model. The base case posed by the manufacturer placed Urolift at almost cost-neutral (£3 cost incurring, based on 2014 prices) compared to TURP, and £418 cost incurring compared to HoLEP. In an additional scenario comparing day-case Urolift with in-patient TURP, the estimated per-patient savings with Urolift were £286 compared with monopolar TURP (mTURP) and £159 compared with bipolar TURP (BiTURP). NICE guidance MTG26 recommends that the case for adoption of Urolift was supported by the evidence, when implemented in a day-case setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krauss, Daniel J., E-mail: dkrauss@beaumont.edu; Ye, Hong; Martinez, Alvaro A.
Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Irmore » to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.« less
NASA Astrophysics Data System (ADS)
Kernen, Kenneth M.; Miles, Brian J.
2000-05-01
Prostate cancer, the most common malignancy in men in the United States, accounts for more than 29% of all male cancers diagnosed and 13% of all cancer deaths. This translates into approximately 200,000 men diagnosed and 37,000 men who will die from the disease this year in this country. A significant number of patients ultimately choose external beam radiation or interstitial radioactive implants (brachytherapy) combined with external beam radiotherapy as their primary treatment. Approximately 25 - 35% of external beam irradiation patients and 20 - 30% of interstitial implants combined with external beam radiotherapy will fail within 10 years. The treatment options for patients with localized radiorecurrent disease include watchful waiting, endocrine therapy, salvage radiotherapy, and salvage radical prostatectomy, cryotherapy and now high intensity focused ultrasound therapy (HIFU). Although some studies regarding watchful waiting demonstrated comparable results to formal treatment for early prostate cancer, other studies have shown metastatic and mortality rates that are significantly higher, and that radiorecurrent patients would have even greater rates of metastasis and progression to death. Prostate cancer cure by means of endocrine therapy is highly unlikely and its role is still one of palliation with a side effect profile which includes hot flashes, osteoporosis, fatigue, loss of muscle mass, anemia, loss of libido and potency. The role of salvage radiotherapy may offer local control, however long term efficacy has yet to be determined. In a recent series, only 50% of the patients were controlled for a mean of four years with salvage radiotherapy. Salvage prostatectomy has the advantage of providing excellent local control and even a cure if the cancer is confined to the prostate or within the surrounding periprostatic tissue. Historically, salvage prostatectomy is technically demanding and fraught with higher complications. In one large series, investigators found rectal injuries in up to 15%, anastomotic strictures in 27% and urinary incontinence in approximately 58%, as well as an overall higher estimated blood loss, transfusions, and hospital stay greater than that of a standard radical retropubic prostatectomy. Cryotherapy also has a significant complication rate with incontinence (73%), impotence (72%), and prolonged dysuria in 67%. In this report, biopsies were negative in 77% but biochemical failure occurred in 58% of patients. High intensity focused ultrasound (HIFU) therapy is a relatively new treatment modality and is being applied transrectally for the treatment of both benign prostatic hyperplasia and adenocarcinoma of the prostate. The therapy is also under evaluation at multiple centers in the United States for the treatment of radiorecurrent prostate cancer. In Europe, it not only being evaluated as treatment for radiorecurrent prostate cancer, but is also being evaluated and offered as a minimally invasive primary therapy for prostate cancers localized to the gland. The technique of HIFU generation has been previously described in detail. The ablation device is comprised of a patient treatment table, main computer, an oscillator, power amplifier, power measurement system, probe movement system, endorectal probe with built-in ultrasound scanner and treatment transducer, and reprography equipment. The patient is administered either a spinal or general anesthesia, positioned on the treatment table on his side with the legs flexed, the endorectal probe is then inserted. The ultrasound imaging is used to detect the contours of the prostate and the target volume to be treated is then calculated. Under computer control, the HIFU device position and then successively repositions the endorectal probe, delivering the high intensity focused ultrasound according to the treatment blocks defined by the surgeon. This sequence then repeats until all sectors of the prostate have been treated. HIFU is generated by high power acoustic transducers, which produce focused ultrasound waves, that generate high temperatures to achieve coagulative necrosis of the target tissue. The ultrasound waves are emitted in discrete, timed bursts with a duration of several seconds. At the focal point of the ultrasound, the temperatures achieved are approximately 85 degrees Celsius, thereby ablating the prostate tissue. An attractive advantage of HIFU is its low risk of morbidity, due to the sudden, short bursts of the intensely focused ultrasound, which, along with the heat generated, are quickly absorbed by the target tissue, thereby protecting the surrounding tissues from damage.
Influence des défauts de la structure du verre sur la résistance mécanique des fibres optiques
NASA Astrophysics Data System (ADS)
Chmel, A.; Baptizmanski, V. V.; Kharshak, A. A.
1992-12-01
For silica (pure and doped) optical fibers prepared from preforms irradiated by thermal neutrons and Ar^+ ions, the measurements of lifetime under transverse stress were carried out. It is found that the neutron bombardment leads to decrease of the lifetime and the strength of fiber while the ion implantation results in increasing of these parameters. The influence of particle irradiation on the glass strength is explained by the generation of structural defects which were observed by the infrared an Raman spectroscopy methods. The direction of the change of mechanical properties of fibers is determined by the type of defects and their distribution in the cross-section of fiber. Des préformes de fibres optiques de silice ont été exposées à un bombardement par des faisceaux de neutrons thermiques et d'ions Ar^+ à énergie de 40 keV afin d'engendrer des défauts de la structure respectivement dans le volume ou dans la couche superficielle des échantillons. Les fibres obtenues des préformes irradiées et non irradiées ont été mises en charge de flexion. On a déterminé leur temps de rupture sous diverses contraintes de traction sur la surface extérieure de la fibre en flexion. On a observé une diminution du temps de rupture des fibres après le bombardement neutronique et une augmentation après l'implantation ionique. L'analyse de la nature des défauts en faisant appel à la spectroscopie infrarouge et Raman a fait ressortir que l'irradiation aux ions entraînait essentiellement des liaisons chimiques dans une fine couche superficielle de l'échantillon alors que l'irradiation aux neutrons occasionnait une déformation des zones du réseau silicique dans toute la section de la préforme et de la fibre. L'amélioration de la résistance mécanique s'explique par une augmentation de la mobilité des éléments structuraux de la matrice de verre par suite d'une rupture partielle des liaisons chimiques et sa diminution par l'apparition de concentrateurs supplémentaires de contraintes à l'échelle moléculaire.
NASA Astrophysics Data System (ADS)
Mountris, K. A.; Bert, J.; Noailly, J.; Rodriguez Aguilera, A.; Valeri, A.; Pradier, O.; Schick, U.; Promayon, E.; Gonzalez Ballester, M. A.; Troccaz, J.; Visvikis, D.
2017-03-01
Prostate volume changes due to edema occurrence during transperineal permanent brachytherapy should be taken under consideration to ensure optimal dose delivery. Available edema models, based on prostate volume observations, face several limitations. Therefore, patient-specific models need to be developed to accurately account for the impact of edema. In this study we present a biomechanical model developed to reproduce edema resolution patterns documented in the literature. Using the biphasic mixture theory and finite element analysis, the proposed model takes into consideration the mechanical properties of the pubic area tissues in the evolution of prostate edema. The model’s computed deformations are incorporated in a Monte Carlo simulation to investigate their effect on post-operative dosimetry. The comparison of Day1 and Day30 dosimetry results demonstrates the capability of the proposed model for patient-specific dosimetry improvements, considering the edema dynamics. The proposed model shows excellent ability to reproduce previously described edema resolution patterns and was validated based on previous findings. According to our results, for a prostate volume increase of 10-20% the Day30 urethra D10 dose metric is higher by 4.2%-10.5% compared to the Day1 value. The introduction of the edema dynamics in Day30 dosimetry shows a significant global dose overestimation identified on the conventional static Day30 dosimetry. In conclusion, the proposed edema biomechanical model can improve the treatment planning of transperineal permanent brachytherapy accounting for post-implant dose alterations during the planning procedure.
Mountris, K A; Bert, J; Noailly, J; Aguilera, A Rodriguez; Valeri, A; Pradier, O; Schick, U; Promayon, E; Ballester, M A Gonzalez; Troccaz, J; Visvikis, D
2017-03-21
Prostate volume changes due to edema occurrence during transperineal permanent brachytherapy should be taken under consideration to ensure optimal dose delivery. Available edema models, based on prostate volume observations, face several limitations. Therefore, patient-specific models need to be developed to accurately account for the impact of edema. In this study we present a biomechanical model developed to reproduce edema resolution patterns documented in the literature. Using the biphasic mixture theory and finite element analysis, the proposed model takes into consideration the mechanical properties of the pubic area tissues in the evolution of prostate edema. The model's computed deformations are incorporated in a Monte Carlo simulation to investigate their effect on post-operative dosimetry. The comparison of Day1 and Day30 dosimetry results demonstrates the capability of the proposed model for patient-specific dosimetry improvements, considering the edema dynamics. The proposed model shows excellent ability to reproduce previously described edema resolution patterns and was validated based on previous findings. According to our results, for a prostate volume increase of 10-20% the Day30 urethra D10 dose metric is higher by 4.2%-10.5% compared to the Day1 value. The introduction of the edema dynamics in Day30 dosimetry shows a significant global dose overestimation identified on the conventional static Day30 dosimetry. In conclusion, the proposed edema biomechanical model can improve the treatment planning of transperineal permanent brachytherapy accounting for post-implant dose alterations during the planning procedure.
Simmat, I; Georg, P; Georg, D; Birkfellner, W; Goldner, G; Stock, M
2012-09-01
The goal of the current study was to evaluate the commercially available atlas-based autosegmentation software for clinical use in prostate radiotherapy. The accuracy was benchmarked against interobserver variability. A total of 20 planning computed tomographs (CTs) and 10 cone-beam CTs (CBCTs) were selected for prostate, rectum, and bladder delineation. The images varied regarding to individual (age, body mass index) and setup parameters (contrast agent, rectal balloon, implanted markers). Automatically created contours with ABAS(®) and iPlan(®) were compared to an expert's delineation by calculating the Dice similarity coefficient (DSC) and conformity index. Demo-atlases of both systems showed different results for bladder (DSC(ABAS) 0.86 ± 0.17, DSC(iPlan) 0.51 ± 0.30) and prostate (DSC(ABAS) 0.71 ± 0.14, DSC(iPlan) 0.57 ± 0.19). Rectum delineation (DSC(ABAS) 0.78 ± 0.11, DSC(iPlan) 0.84 ± 0.08) demonstrated differences between the systems but better correlation of the automatically drawn volumes. ABAS(®) was closest to the interobserver benchmark. Autosegmentation with iPlan(®), ABAS(®) and manual segmentation took 0.5, 4 and 15-20 min, respectively. Automatic contouring on CBCT showed high dependence on image quality (DSC bladder 0.54, rectum 0.42, prostate 0.34). For clinical routine, efforts are still necessary to either redesign algorithms implemented in autosegmentation or to optimize image quality for CBCT to guarantee required accuracy and time savings for adaptive radiotherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Trofimov, A; Sharp, G
Purpose: To investigate the impact of anatomy/setup variations on standard vs. hypofractionated anterolateral pencil beam scanning (PBS) proton therapy for prostate cancer. Methods: Six prostate cancer patients treated with double-scattering proton therapy, who underwent weekly verification CT scans were selected. Implanted fiducials were used for localization, and endorectal balloons for immobilization. New PBS plans using combination of lateral and anterior-oblique (AO) (±35 deg) beams were created. AO beams were added to spare the femoral heads during hypofractionation. Lateral beams delivered 50.4 Gy(RBE) to prostate plus 5-15mm of seminal vesicles and AO beams 28.8 Gy(RBE) to prostate, in 44 fractions. PTVmore » was laterally expanded by 2.5% to account for range uncertainty. No range margins were applied for AO beams, assuming delivery with in-vivo range verification. Field-specific apertures with 1.2cm margin were used. Spot size was ∼9.5mm sigma for 172MeV @isocenter in air. Plans were optimized as single-field-uniform-dose with ∼5% maximum non-uniformity. The planned dose was recomputed on each weekly CT after aligning the fiducials with the simulation CT, scaled and accumulated via deformable image registration. Hypofractionated treatments with 12 and 5 fractions were considered. Equivalent doses were calculated for prostate (α/β= 1.5Gy), bladder and rectum (α/β= 3Gy). Results: The biological equivalent prostate dose was 86.2 and 92.9 Gyeq for the hypofractionation scenarios at 4.32 and 7.35 Gy/fx, respectively. The equivalent prostate D98 was degraded by on average 2.7 Gyeq for standard, and 3.1 and 4.0 Gyeq for the hypofractionated plans after accumulation. Differences between accumulated and planned Dmean/D2/EUD were generally reduced when reducing the number of fractions for bladder and rectum. The average Dmean/D2/EUD differences over all patients and organs-at-risk were 0.74/4.0/9.23, 0.49/3.64/5.51, 0.37/3.21/3.49 Gyeq for 44, 12 and 5 fractions. Conclusion: Hypofractionation makes proton therapy of prostate more susceptible to interfractional motion-induced target dose degradation compared to the standard fractionation.« less
Rahim, Said; Minas, Tsion; Hong, Sung-Hyeok; Justvig, Sarah; Çelik, Haydar; Kont, Yasemin Saygideger; Han, Jenny; Kallarakal, Abraham T.; Kong, Yali; Rudek, Michelle A.; Brown, Milton L.; Kallakury, Bhaskar; Toretsky, Jeffrey A.; Üren, Aykut
2014-01-01
Background The erythroblastosis virus E26 transforming sequences (ETS) family of transcription factors consists of a highly conserved group of genes that play important roles in cellular proliferation, differentiation, migration and invasion. Chromosomal translocations fusing ETS factors to promoters of androgen responsive genes have been found in prostate cancers, including the most clinically aggressive forms. ERG and ETV1 are the most commonly translocated ETS proteins. Over-expression of these proteins in prostate cancer cells results in a more invasive phenotype. Inhibition of ETS activity by small molecule inhibitors may provide a novel method for the treatment of prostate cancer. Methods and Findings We recently demonstrated that the small molecule YK-4-279 inhibits biological activity of ETV1 in fusion-positive prostate cancer cells leading to decreased motility and invasion in-vitro. Here, we present data from an in-vivo mouse xenograft model. SCID-beige mice were subcutaneously implanted with fusion-positive LNCaP-luc-M6 and fusion-negative PC-3M-luc-C6 tumors. Animals were treated with YK-4-279, and its effects on primary tumor growth and lung metastasis were evaluated. YK-4-279 treatment resulted in decreased growth of the primary tumor only in LNCaP-luc-M6 cohort. When primary tumors were grown to comparable sizes, YK-4-279 inhibited tumor metastasis to the lungs. Expression of ETV1 target genes MMP7, FKBP10 and GLYATL2 were reduced in YK-4-279 treated animals. ETS fusion-negative PC-3M-luc-C6 xenografts were unresponsive to the compound. Furthermore, YK-4-279 is a chiral molecule that exists as a racemic mixture of R and S enantiomers. We established that (S)-YK-4-279 is the active enantiomer in prostate cancer cells. Conclusion Our results demonstrate that YK-4-279 is a potent inhibitor of ETV1 and inhibits both the primary tumor growth and metastasis of fusion positive prostate cancer xenografts. Therefore, YK-4-279 or similar compounds may be evaluated as a potential therapeutic tool for treatment of human prostate cancer at different stages. PMID:25479232
NASA Astrophysics Data System (ADS)
Warrell, Gregory R.
Hyperthermia has long been known as a radiation therapy sensitizer of high potential; however successful delivery of this modality and integrating it with radiation have often proved technically difficult. We present the dual-modality thermobrachytherapy (TB) seed, based on the ubiquitous low dose-rate (LDR) brachytherapy permanent implant, as a simple and effective combination of hyperthermia and radiation therapy. Heat is generated from a ferromagnetic or ferrimagnetic core within the seed, which produces Joule heating by eddy currents. A strategically-selected Curie temperature provides thermal self-regulation. In order to obtain a uniform and sufficiently high temperature distribution, additional hyperthermia-only (HT-only) seeds are proposed to be used in vacant spots within the needles used to implant the TB seeds; this permits a high seed density without the use of additional needles. Experimental and computational studies were done both to optimize the design of the TB and HT-only seeds and to quantitatively assess their ability to heat and irradiate defined, patient-specific targets. Experiments were performed with seed-sized ferromagnetic samples in tissue-mimicking phantoms heated by an industrial induction heater. The magnetic and thermal properties of the seeds were studied computationally in the finite element analysis (FEA) solver COMSOL Multiphysics, modelling realistic patient-specific seed distributions. These distributions were derived from LDR permanent prostate implants previously conducted at our institution; various modifications of the seeds' design were studied. The calculated temperature distributions were analyzed by generating temperature-volume histograms, which were used to quantify coverage and temperature homogeneity for a range of blood perfusion rates, as well as for a range of seed Curie temperatures and thermal power production rates. The impact of the interseed attenuation and scatter (ISA) effect on radiation dose distributions of this seed was also quantified by Monte Carlo studies in the software package MCNP5. Experimental and computational analyses agree that the proposed seeds may heat a defined target with safe and attainable seed spacing and magnetic field parameters. These studies also point to the use of a ferrite-based ferrimagnetic core within the seeds, a design that would deliver hyperthermia of acceptable quality even for the high rate of blood perfusion in prostate tissue. The loss of radiation coverage due to the ISA effect of distributions of TB and HT-only seeds may be rectified by slightly increasing the prescribed dose in standard dose superposition-based treatment planning software. A systematic approach of combining LDR prostate brachytherapy with hyperthermia is thus described, and its ability to provide sufficient and uniform temperature distributions in realistic patient-specific implants evaluated. Potential improvements to the previously reported TB seed design are discussed based on quantitative evaluation of its operation and performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basran, P. S; Beckham, WA; Baxter, P
Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent I-125 prostate brachytherapy implant patient who developed colo-rectal cancer and required surgery 6 months after brachytherapy. The first consideration is identifying the risk from unwarranted radiation to the patientmore » and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling for radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. These strategies may include applying the concepts of ALARA, the use of protective equipment and developing a best practice strategy with the operating room team. We summarize this experience with some guidelines: If the surgical procedure is near (ex: 5 cm) of the implant; and, the surgical intervention may dislodge radioisotopes enough to compromise treatment or introduces radiation safety risks; and, the radioisotope has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.« less
Extracellular Hsp90 as a Novel Epigenetic of EMT and Metastatic Risk in Prostate Cancer
2015-12-01
kidney from each experiment were xenografted in three mice (total of six repli- cates). Mice were sacrificed after 7– 8 weeks, and grafts were harvested...Histological assessment of xenografts was performed by H&E staining. Calculation of xenograft vol- umes was performed using the following formula: volume... xenograft tumors originat- ing from the indicated ARCaPE derivatives 7– 8 weeks after implantation. Bottom, quantified analysis of corresponding tumors (n
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, W; Merrick, G; Kurko, B
Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from themore » phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soliman, A; Elzibak, A; Fatemi, A
Purpose: To propose a novel framework for accurate model-based dose calculations using only MR images for LDR prostate and breast seed implant brachytherapy. Methods: Model-based dose calculation methodologies recommended by TG-186 require further knowledge about specific tissue composition, which is challenging with MRI. However, relying on MRI-only for implant dosimetry would reduce the soft tissue delineation uncertainty, costs, and uncertainties associated with multi-modality registration and fusion processes. We propose a novel framework to address this problem using quantitative MRI acquisitions and reconstruction techniques. The framework includes three steps: (1) Identify the locations of seeds(2) Identify the presence (or absence) ofmore » calcification(s)(3) Quantify the water and fat content in the underlying tissueSteps (1) and (2) consider the sources that limit patient dosimetry, particularly the inter-seed attenuation and the calcified regions; while step (3) targets the quantification of the tissue composition to consider the heterogeneities in the medium. Our preliminary work has shown that the seeds and the calcifications can be identified with MRI using both the magnitude and the phase images. By employing susceptibility-weighted imaging with specific post-processing techniques, the phase images can be further explored to distinguish the seeds from the calcifications. Absolute quantification of tissue, water, and fat content is feasible and was previously demonstrated in phantoms and in-vivo applications, particularly for brain diseases. The approach relies on the proportionality of the MR signal to the number of protons in an image volume. By employing appropriate correction algorithms for T1 - and T2*-related biases, B1 transmit and receive field inhomogeneities, absolute water/fat content can be determined. Results: By considering calcification and interseed attenuation, and through the knowledge of water and fat mass density, accurate patient-specific implant dosimetry can be achieved with MRI-only. Conclusion: The proposed framework showed that model-based dose calculation is feasible using MRI-only state-of-the-art techniques.« less
Isharwal, Sumit; Modi, Shrey; Arora, Nivedita; Uhlrich, Charles; Giri, Bhuwan; Barlass, Usman; Soubra, Ayman; Chugh, Rohit; Dehm, Scott M; Dudeja, Vikas; Saluja, Ashok; Banerjee, Sulagna; Konety, Badrinath
2017-05-01
With almost 30,000 deaths per year, prostate cancer is the second-leading cause of cancer-related death in men. Androgen Deprivation Therapy (ADT) has been the corner stone of prostate cancer treatment for decades. However, despite an initial response of prostate cancer to ADT, this eventually fails and the tumors recur, resulting in Castration Resistant Prostate Cancer (CRPC). Triptolide, a diterpene triepoxide, has been tested for its anti-tumor properties in a number of cancers for over a decade. Owing to its poor solubility in aqueous medium, its clinical application had been limited. To circumvent this problem, we have synthesized a water-soluble pro-drug of triptolide, Minnelide, that is currently being evaluated in a Phase 1 clinical trial against gastrointestinal tumors. In the current study, we assessed the therapeutic potential of Minnelide and its active compound triptolide against androgen dependent prostate cancer both in vitro as well as in vivo. Cell viability was measured by a MTT based assay after treating prostate cancer cells with multiple doses of triptolide. Apoptotic cell death was measured using a caspase 3/7 activity. Androgen Receptor (AR) promoter-binding activity was evaluated by using luciferase reporter assay. For evaluating the effect in vivo, 22Rv1 cells were implanted subcutaneously in animals, following which, treatment was started with 0.21 mg/kg Minnelide. Our study showed that treatment with triptolide induced apoptotic cell death in CRPC cells. Triptolide treatment inhibited AR transcriptional activity and decreased the expression of AR and its splice variants both at the mRNA and the protein level. Our studies show that triptolide inhibits nuclear translocation of Sp1, resulting in its decreased transcriptional activity leading to downregulation of AR and its splice variants in prostate cancer cells. In vivo, Minnelide (0.21 mg/kg) regressed subcutaneous tumors derived from CRPC 22RV1 at our study endpoint. Our animal studies further confirmed that Minnelide was more efficacious than the standard of care therapies, Docetaxel and Enzalutamide. Our study indicates that Minnelide is very effective as a therapeutic option against CRPC at a dose that is currently tolerated by patients in the ongoing clinical trials. Prostate 77: 584-596, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Haworth, Annette; Mears, Christopher; Betts, John M; Reynolds, Hayley M; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A
2016-01-07
Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The 'biological optimisation' considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.
NASA Astrophysics Data System (ADS)
Haworth, Annette; Mears, Christopher; Betts, John M.; Reynolds, Hayley M.; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A.
2016-01-01
Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The ‘biological optimisation’ considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.
Whaley, J. Taylor; Levy, Lawrence B.; Swanson, David A.; Pugh, Thomas J.; Kudchadker, Rajat J.; Bruno, Teresa L.; Frank, Steven J.
2013-01-01
Purpose Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile-volume receiving 100% of the prescribed dose (V100) were calculated. Results At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p=0.04) and age (p=0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients over 70 maintained optimal potency (p=0.02). Diabetes was related to a decline in potency (p=0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p<0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry. PMID:22300559
Whaley, J Taylor; Levy, Lawrence B; Swanson, David A; Pugh, Thomas J; Kudchadker, Rajat J; Bruno, Teresa L; Frank, Steven J
2012-04-01
Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whaley, J. Taylor; Levy, Lawrence B.; Swanson, David A.
Purpose: Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials: Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. Results: Atmore » baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions: Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicolae, A; Department of Physics, Ryerson University, Toronto, ON; Lu, L
Purpose: A novel, automated, algorithm for permanent prostate brachytherapy (PPB) treatment planning has been developed. The novel approach uses machine-learning (ML), a form of artificial intelligence, to substantially decrease planning time while simultaneously retaining the clinical intuition of plans created by radiation oncologists. This study seeks to compare the ML algorithm against expert-planned PPB plans to evaluate the equivalency of dosimetric and clinical plan quality. Methods: Plan features were computed from historical high-quality PPB treatments (N = 100) and stored in a relational database (RDB). The ML algorithm matched new PPB features to a highly similar case in the RDB;more » this initial plan configuration was then further optimized using a stochastic search algorithm. PPB pre-plans (N = 30) generated using the ML algorithm were compared to plan variants created by an expert dosimetrist (RT), and radiation oncologist (MD). Planning time and pre-plan dosimetry were evaluated using a one-way Student’s t-test and ANOVA, respectively (significance level = 0.05). Clinical implant quality was evaluated by expert PPB radiation oncologists as part of a qualitative study. Results: Average planning time was 0.44 ± 0.42 min compared to 17.88 ± 8.76 min for the ML algorithm and RT, respectively, a significant advantage [t(9), p = 0.01]. A post-hoc ANOVA [F(2,87) = 6.59, p = 0.002] using Tukey-Kramer criteria showed a significantly lower mean prostate V150% for the ML plans (52.9%) compared to the RT (57.3%), and MD (56.2%) plans. Preliminary qualitative study results indicate comparable clinical implant quality between RT and ML plans with a trend towards preference for ML plans. Conclusion: PPB pre-treatment plans highly comparable to those of an expert radiation oncologist can be created using a novel ML planning model. The use of an ML-based planning approach is expected to translate into improved PPB accessibility and plan uniformity.« less
Zhang, Pengpeng; Happersett, Laura; Ravindranath, Bosky; Zelefsky, Michael; Mageras, Gig; Hunt, Margie
2016-01-01
Purpose: Robust detection of implanted fiducials is essential for monitoring intrafractional motion during hypofractionated treatment. The authors developed a plan optimization strategy to ensure clear visibility of implanted fiducials and facilitate 3D localization during volumetric modulated arc therapy (VMAT). Methods: Periodic kilovoltage (kV) images were acquired at 20° gantry intervals and paired with simultaneously acquired 4.4° short arc megavoltage digital tomosynthesis (MV-DTS) to localize three fiducials during VMAT delivery for hypofractionated prostate cancer treatment. Beginning with the original optimized plan, control point segments where fiducials were consistently blocked by multileaf collimator (MLC) within each 4.4° MV-DTS interval were first identified. For each segment, MLC apertures were edited to expose the fiducial that led to the least increase in the cost function. Subsequently, MLC apertures of all control points not involved with fiducial visualization were reoptimized to compensate for plan quality losses and match the original dose–volume histogram. MV dose for each MV-DTS was also kept above 0.4 MU to ensure acceptable image quality. Different imaging (gantry) intervals and visibility margins around fiducials were also evaluated. Results: Fiducials were consistently blocked by the MLC for, on average, 36% of the imaging control points for five hypofractionated prostate VMAT plans but properly exposed after reoptimization. Reoptimization resulted in negligible dosimetric differences compared with original plans and outperformed simple aperture editing: on average, PTV D98 recovered from 87% to 94% of prescription, and PTV dose homogeneity improved from 9% to 7%. Without violating plan objectives and compromising delivery efficiency, the highest imaging frequency and largest margin that can be achieved are a 10° gantry interval, and 15 mm, respectively. Conclusions: VMAT plans can be made to accommodate MV-kV imaging of fiducials. Fiducial visualization rate and workflow efficiency are significantly improved with an automatic modification and reoptimization approach. PMID:27147314
2014-04-01
skin cancer model and the other in an implantable breast tumor model, depletion of CD20+ cells removed regulatory B cells, which could be...immunosuppressive (13, 14). Interestingly, a group recently studied the effect of B cell depletion using the same αCD20 antibody in a breast cancer model, a... breast cancer-specific immune responses and their correlation to prognosis. Cancer research 69, 8420-8428 (2009); published online EpubNov 1
Paranjpe, Rutugandha; Gundala, Sushma R; Lakshminarayana, N; Sagwal, Arpana; Asif, Ghazia; Pandey, Anjali; Aneja, Ritu
2013-07-01
Plant extracts, a concoction of bioactive non-nutrient phytochemicals, have long served as the most significant source of new leads for anticancer drug development. Explored for their unique medicinal properties, the leaves of Piper betel, an evergreen perennial vine, are a reservoir of phenolics with antimutagenic, antitumor and antioxidant activities. Here, we show that oral feeding of betel leaf extract (BLE) significantly inhibited the growth of human prostate xenografts implanted in nude mice compared with vehicle-fed controls. To gain insights into the 'active principles', we performed a bioactivity-guided fractionation of methanolic BLE employing solvents of different polarity strengths using classical column chromatography. This approach yielded 15 fractions, which were then pooled to 10 using similar retention factors on thin-layer chromatographs. Bioactivity assays demonstrated that one fraction in particular, F2, displayed a 3-fold better in vitro efficacy to inhibit proliferation of prostate cancer cells than the parent BLE. The presence of phenols, hydroxychavicol (HC) and chavibetol (CHV), was confirmed in F2 by nuclear magnetic resonance, high-performance liquid chromatography and mass spectroscopy. Further, the HC containing F2 subfraction was found to be ~8-fold more potent than the F2 subfraction that contained CHV, in human prostate cancer PC-3 cells as evaluated by the 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyl tetrazolium bromide assay. Removing CHV from F2 remarkably decreased the IC50 of this fraction, indicating that HC is perhaps the major bioactive constituent, which is present to an extent of 26.59% in BLE. These data provide evidence that HC is a potential candidate for prostate cancer management and warrants further preclinical evaluation.
Kuber, W; Treu, T; Kratzik, C; Girsch, E; Zeillinger, R; Spona, J
1990-11-09
79 patients with locally advanced and/or metastatic prostate cancer were treated by means of a biodegradeable depot formulation of the luteinizing hormone releasing hormone analogue Goserelin (Zoladex). All patients received 3.6 mg depot Goserelin (Zoladex 3.6 mg implantate) subcutaneously into the anterior abdominal wall at 4 weekly intervals. The average time of observation was 24.2 months. The best objective response rate was found in 62%. Serum testosterone levels initially increased after the first depot injection and then decreased ultimately to castrate range (less than 0.6 ng/ml) between day 15 and day 27 (median 21) in the majority of patients. Castrate testosterone levels were still found 48 months after the start of treatment with depot Goserelin. 6 months after institution of treatment in 66.7% of cases evident signs of histological regression were found in the primary tumour tissue. Adenocarcinoma presented with a highly significantly better response pattern than anaplastic carcinoma. In animal experiments a single dose of 1 mg depot Goserelin was administered to adult male rats and the effect on serum testosterone levels and target organs (testes and ventral prostate) were investigated. Mean testosterone levels (mean = 0.31 ng/ml) decreased to castrate range (less than 0.3 ng/ml). 4 weeks after depot injection weight of the testes and prostate weight were significantly reduced. However 8 weeks after administration of 1 mg depot Goserelin there was no significant between the control group and the treated group. We conclude that the depot formulation of Goserelin (Zoladex) is effective, simple, practicable and safe in the treatment of advanced prostatic cancer. Current clinical studies are confirming the importance of reversible medical castration by LHRH agonists before radical prostatectomy.
Myers, Michael A; Hagan, Michael P; Todor, Dorin; Gilbert, Lynn; Mukhopadhyay, Nitai; Randolf, Jessica; Heimiller, Jeffrey; Anscher, Mitchell S
2012-01-01
A Phase I/II protocol was conducted to examine the toxicity and efficacy of the combination of intensity-modulated radiation therapy (IMRT) with a single-fraction high-dose-rate (HDR) brachytherapy implant. From 2001 through 2006, 26 consecutive patients were treated on the trial. The primary objective was to demonstrate a high rate of completion without experiencing a treatment-limiting toxicity. Eligibility was limited to patients with T stage ≤2b, prostate-specific antigen (PSA) ≤20, and Gleason score ≤7. Treatment began with a single HDR fraction of 6Gy to the entire prostate and 9Gy to the peripheral zone, followed by IMRT optimized to deliver in 28 fractions with a normalized total dose of 70Gy. Patients received 50.4Gy to the pelvic lymph node. The prostate dose (IMRT and HDR) resulted in an average biologic equivalent dose >128Gy (α/β=3). Patients whose pretreatment PSA was ≥10ng/mL, Gleason score 7, or stage ≥T2b received short-term androgen ablation. Median followup was 53 months (9-68 months). There were no biochemical failures by either the American Society of Therapeutic Radiology and Oncology or the Phoenix definitions. The median nadir PSA was 0.32ng/mL. All the 26 patients completed the treatment as prescribed. The rate of Grade 3 late genitourinary toxicity was 3.8% consisting of a urethral stricture. There was no other Grade 3 or 4 genitourinary or gastrointestinal toxicities. Single-fraction HDR-boosted IMRT is a safe effective method of dose escalation for localized prostate cancer. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Spencer, Sandra; Guerrieri, Mario; Ding, Wei; Goharian, Mehran; Ho, Huong; Ng, Michael; Healey, Danielle; Tan, Alwin; Cham, Chee; Joon, Daryl Lim; Lawrentschuk, Nathan; Travis, Douglas; Sengupta, Shomik; Chan, Yee; Troy, Andrew; Pham, Trung; Clarke, David; Liodakis, Peter; Bolton, Damien
2018-01-01
Purpose To report the 5-year biochemical relapse-free survival (BRFS), overall survival (OS), and long-term toxicity outcomes of patients treated with low-dose-rate (LDR) brachytherapy as monotherapy for low- to intermediate-risk prostate cancer. Material and methods Between 2004 and 2011, 371 patients were treated with LDR brachytherapy as monotherapy. Of these, 102 patients (27%) underwent transurethral resection of the prostate (TURP) prior to implantation. Follow-up was performed every 3 months for 12 months, then every 6 months over 4 years and included prostate specific antigen evaluation. The biochemical relapse-free survival (BRFS) was defined according to the Phoenix criteria. Acute and late toxicities were documented using the Common Terminology Criteria for Adverse Events version 4.0. The BRFS and OS estimates were calculated using Kaplan-Meier plots. Univariate and multivariate analyses were performed to evaluate outcomes by pre-treatment clinical prognostic factors and radiation dosimetry. Results The median follow-up of all patients was 5.45 years. The 5-year BRFS and OS rates were 95% and 96%, respectively. The BRFS rates for patients with Gleason score (GS) > 7 and GS ≤ 6 were 96% and 91% respectively (p = 0.06). On univariate analysis, T1 and T2 staging, risk-group classification, and prostate volumes had no impact on survival at 5 years (p > 0.1). Late grade 2 and 3 genitourinary (GU) toxicities were observed in 10% and 5% of patients respectively. Additionally, patients with prior TURP had a greater incidence of late grade 2 or 3 urinary retention (p = 0.001). There were 14 deaths in total; however, none were attributed to prostate cancer. Conclusions LDR brachytherapy is an effective treatment option in low- to intermediate-risk prostate cancer patients. We observed low biochemical relapse rates and minimal GU toxicities several years after treatment in patients with or without TURP. However, a small risk of urinary retention was observed in some patients. PMID:29789764
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smitsmans, Monique H.P.; Bois, Josien de; Sonke, Jan-Jakob
Purpose: The objectives of this study were to quantify residual interfraction displacement of seminal vesicles (SV) and investigate the efficacy of rotation correction on SV displacement in marker-based prostate image-guided radiotherapy (IGRT). We also determined the effect of marker registration on the measured SV displacement and its impact on margin design. Methods and Materials: SV displacement was determined relative to marker registration by using 296 cone beam computed tomography scans of 13 prostate cancer patients with implanted markers. SV were individually registered in the transverse plane, based on gray-value information. The target registration error (TRE) for the SV due tomore » marker registration inaccuracies was estimated. Correlations between prostate gland rotations and SV displacement and between individual SV displacements were determined. Results: The SV registration success rate was 99%. Displacement amounts of both SVs were comparable. Systematic and random residual SV displacements were 1.6 mm and 2.0 mm in the left-right direction, respectively, and 2.8 mm and 3.1 mm in the anteroposterior (AP) direction, respectively. Rotation correction did not reduce residual SV displacement. Prostate gland rotation around the left-right axis correlated with SV AP displacement (R{sup 2} = 42%); a correlation existed between both SVs for AP displacement (R{sup 2} = 62%); considerable correlation existed between random errors of SV displacement and TRE (R{sup 2} = 34%). Conclusions: Considerable residual SV displacement exists in marker-based IGRT. Rotation correction barely reduced SV displacement, rather, a larger SV displacement was shown relative to the prostate gland that was not captured by the marker position. Marker registration error partly explains SV displacement when correcting for rotations. Correcting for rotations, therefore, is not advisable when SV are part of the target volume. Margin design for SVs should take these uncertainties into account.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geneser, S; Cunha, J; Pouliot, J
Purpose: HDR brachytherapy consensus dose tolerance recommendations for organs at risk (OARs) remain widely debated. Prospective trials reporting metrics must be sufficiently data-dense to assess adverse affects and identify optimally predictive tolerances. We explore the tradeoffs between reporting dose-metrics versus volume-metrics and the potential impact on trial outcome analysis and tolerance recommendations. Methods: We analyzed 26 prostate patients receiving 15 Gy HDR single-fraction brachytherapy boost to 45 Gy external beam radiation therapy and 28 cervical patients receiving 28 Gy HDR brachytherapy monotherapy in 4 fractions using 2 implants. For each OAR structure, a robust linear regression fit was performed formore » the dose-metrics as a function of the volume-metrics. The plan quality information provided by recommended dose-metric and volume-metric values were compared. Results: For prostate rectal dose, D2cc and V75 lie close to the regression line, indicating they are similarly informative. Two outliers for prostate urethral dose are substantially different from the remaining cohort in terms of D0.1cc and V75, but not D1cc, suggesting the choice of reporting dose metric is essential. For prostate bladder and cervical bladder, rectum, and bowel, dose outliers are more apparent via V75 than recommended dose-metrics. This suggests that for prostate bladder dose and all cervical OAR doses, the recommended volume-metrics may be better predictors of clinical outcome than dose-metrics. Conclusion: For plan acceptance criteria, dose and volume-metrics are reciprocally equivalent. However, reporting dosemetrics or volume-metrics alone provides substantially different information. Our results suggest that volume-metrics may be more sensitive to differences in planned dose, and if one metric must be chosen, volumemetrics are preferable. However, reporting discrete DVH points severely limits the ability to identify planning tolerances most predictive of adverse effects. Thus, we recommend that full OAR DVH reporting be required for future prospective trials.« less
The experience of artificial urinary sphincter implantation by a single surgeon in 15 years.
Shen, Yuan-Chi; Chiang, Po-Hui
2013-03-01
Artificial urinary sphincter (AUS) is the gold standard treatment for urinary incontinence owing to sphincter incompetence. We reviewed our experience in AUS implantation. From 1995 to 2009, 19 patients underwent 25 AUS implantations performed by a single surgeon. The cause of incontinence was sphincter incompetence, which was secondary to prostate surgery, neurogenic bladder, radiation, and post-traumatic urethral lesion. Twenty-three prostheses were placed in the bulbar urethra for male patients: 11 AUS cuffs were placed through the perineal approach and 12 through the penoscrotal approach. Two procedures were applied over the bladder neck for the female patients. Through a retrospective review of charts, continence and complications were analyzed. The mean follow-up time was 50.0 ± 42.9 months (range: 2-146 months). There were 16 successful surgeries (64%), and these patients were free from the need for a pad. In eight surgeries (32%), the devices were removed due to infection, while one implantation (4%) was unsuccessful due to perforation into the bulbar urethra. There was a statistically significant difference (p = 0.024) in failure rates between patients who received radiotherapy (100%) and other patients (22.7%). There was no statistically significant difference in dry and revision rates (p > 0.05) between the perineal and penoscrotal approach. Accordingly, over half of the patients with total incontinence benefitted from AUS implantation. In consideration of the high failure rate for patients receiving radiotherapy, caution should be exercised in the use of implantation. Secondary implantation has a satisfactory success rate in selected patients. The same success rate was noted for both perineal and penoscrotal approaches. Copyright © 2013. Published by Elsevier B.V.
Alongi, Filippo; Cozzi, Luca; Arcangeli, Stefano; Iftode, Cristina; Comito, Tiziana; Villa, Elisa; Lobefalo, Francesca; Navarria, Pierina; Reggiori, Giacomo; Mancosu, Pietro; Clerici, Elena; Fogliata, Antonella; Tomatis, Stefano; Taverna, Gianluigi; Graziotti, Pierpaolo; Scorsetti, Marta
2013-07-08
To evaluate the feasibility and early side effects of a short course hypo-fractionated SBRT programme with Volumetric Modulated Arc Therapy (VMAT) and Flattening Filter Free (FFF) beams. A prospective phase I-II study, started on February 2012. Inclusion criteria were: age ≤ 80 years, WHO-PS ≤ 2, PSA ≤ 20 ng/ml, histologically proven prostate adenocarcinoma, T1-T2 stage, no distant metastases, no previous surgery other than TURP, no malignant tumours in the previous 5 years, IPSS 0-7. The schedule was 35 Gy in 5 alternative days. SBRT was delivered with RapidArc VMAT, with 10MV FFF photons. Toxicity assessment was performed according to CTCAE v4.0 scale. EPIC questionnaires assessed Quality-of-Life. Neo-adjuvant/concomitant hormonal-therapy was prescribed according to risk classification. SpaceOAR™ gel was optionally implanted to increase the separation space between the prostate and the rectal wall. Median follow-up was 11 months (range: 5-16); 40 patients were recruited in the protocol and treated. According to NCCN criteria, 26/40 patients were low-risk and 14/40 were intermediate risk. Median age was 70 years (56-80), median initial PSA was 6.25 ng/ml (0.50-13.43 ng/ml). Median Gleason score was 6 (6-7). All patients completed the treatment as programmed (median 11.8 days (9-22). Acute Toxicities were as follow: Rectum G0: 30/40 cases (75%); G1: 6/40 (15%); G2: 4/40 (10%). Genito-urinary: G0: 16/40 (40%); G1: 8/40 (20%); G2: 16/34 (40%). In two G2 urinary retention cases, intermittent catheter was needed. No acute G3 or greater toxicity was found. Median treatment time was 126 sec (120-136). SpaceOAR™ was implanted in 8 patients. PSA reduction from the pre-treatment value of the marker was documented in all patients. Early findings suggest that SBRT with RapidArc and FFF beams for prostate cancer in 5 fractions is feasible and tolerated in acute setting. Longer follow-up is needed for assessment of late toxicity and outcome.
Technique of after-loading interstitial implants.
Syed, A M; Feder, B H
1977-01-01
Interstitial implants are either removable or permanent (and occasionally a combination of both). Permanent implants are generally utilized where tumors are not accessible enough to permit easy removal of sources or where accurate source distribution is less critical. They are useful for cancers of the lung, pancreas, prostate, bladder, lymph nodes, etc. Radon and gold-198 have been largely replaced by iodine-125. Our major interests are in the removable after-loading iridium-192 implant techniques. Template (steel guide) and non-template (plastic tube) techniques are utilized. Templates are preferred where the tumor volume can only be approached from one side and where accurate positioning of sources would otherwise be difficult. They are useful for cancers of the cervix, vagina, urethra, and rectum. Non-template (plastic tube) techniques are preferred where the tumor volume can be approached from at least two sides and where templates are either not feasible or not essential for accurate positioning of sources. The single needle non-template approach is useful for cancers of lip, nodes, and breast (plastic button) and for cancers of the oral cavity and oropharynx (gold button). The paired needle non-template approach is useful for cancers of the gum, retromolar trigone, and base of tongue (loop technique) and for cancers of the palate (arch technique). Procedures for each technique are described in detail.
Sun, Feng; Indran, Inthrani R.; Zhang, Zhi Wei; Tan, M.H.Eileen; Li, Yu; Lim, Z.L.Ryan; Hua, Rui; Yang, Chong; Soon, Fen-Fen; Li, Jun; Xu, H.Eric; Cheung, Edwin; Yong, Eu-Leong
2015-01-01
Persistent androgen receptor (AR) signaling is the key driving force behind progression and development of castration-resistant prostate cancer (CRPC). In many patients, AR COOH-terminal truncated splice variants (ARvs) play a critical role in contributing to the resistance against androgen depletion therapy. Unfortunately, clinically used antiandrogens like bicalutamide (BIC) and enzalutamide (MDV), which target the ligand binding domain, have failed to suppress these AR variants. Here, we report for the first time that a natural prenylflavonoid, icaritin (ICT), can co-target both persistent AR and ARvs. ICT was found to inhibit transcription of key AR-regulated genes, such as KLK3 [prostate-specific antigen (PSA)] and ARvs-regulated genes, such as UBE2C and induce apoptosis in AR-positive prostate cancer (PC) cells. Mechanistically, ICT promoted the degradation of both AR and ARvs by binding to arylhydrocarbon-receptor (AhR) to mediate ubiquitin-proteasomal degradation. Therefore, ICT impaired AR transactivation in PC cells. Knockdown of AhR gene restored AR stability and partially prevented ICT-induced growth suppression. In clinically relevant murine models orthotopically implanted with androgen-sensitive and CRPC cells, ICT was able to target AR and ARvs, to inhibit AR signaling and tumor growth with no apparent toxicity. Our results provide a mechanistic framework for the development of ICT, as a novel lead compound for AR-positive PC therapeutics, especially for those bearing AR splice variants. PMID:25908644
Medical malpractice of prostate brachytherapy.
Elliott, Kathryn; Wallner, Kent; Merrick, Gregory; Herstein, Paul
2004-01-01
To summarize the basis for brachytherapy-associated legal complaints. The cases summarized here were those worked on by one author (KW) from 1992 through 2002. Summary information about cases is kept solely for the purpose of informing opposing counsel regarding past experience as a defendant or expert witness. No information summarized here is kept for medical research purposes. KW was the defendant in three cases, and an expert witness in the remaining 10 cases. Eleven cases were initiated due to a prostatic-rectal fistula--an abnormal communication between the prostatic urethra and rectum formed because of breakdown of irradiated tissue. Of the cases not involving a fistula, one was initiated due to chronic urinary burning, and the other arose from a patient identification mix-up, such that the plaintiff was treated with the implant planned for another patient. The principal physician defendant(s), after pre-trial winnowing, was the radiation oncologist alone in eight cases and the radiation oncologist and the urologist in five cases. In no case was a urologist named as a defendant without the radiation oncologist. None of the eleven rectal fistula cases involved an egregious seed placement error. Instead, plaintiff attorneys typically claimed breach of standard for care for what most physicians would likely consider to be variations within the standard of care. Prostate brachytherapists should brace themselves for the likelihood of more lawsuits. In addition to fistulas, plaintiff attorneys are likely to devise more bases for lawsuits in the future.
Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu Wu; Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8; Yuchi Ming
Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped;more » the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.« less
Struss, Werner J; Tan, Zheng; Zachkani, Payam; Moskalev, Igor; Jackson, John K; Shademani, Ali; D'Costa, Ninadh M; Raven, Peter A; Frees, Sebastian; Chavez-Munoz, Claudia; Chiao, Mu; So, Alan I
2017-05-01
The vast majority of prostate cancer presents clinically localized to the prostate without evidence of metastasis. Currently, there are several modalities available to treat this particular disease. Despite radical prostatectomy demonstrating a modest prostate cancer specific mortality benefit in the PIVOT trial, several novel modalities have emerged to treat localized prostate cancer in patients that are either not eligible for surgery or that prefer an alternative approach. Athymic nude mice were subcutaneously inoculated with prostate cancer cells. The mice were divided into four cohorts, one cohort untreated, two cohorts received docetaxel (10 mg/kg) either subcutaneously (SC) or intravenously (IV) and the fourth cohort was treated using the magnetically-actuated docetaxel delivery device (MADDD), dispensing 1.5 μg of docetaxel per 30 min treatment session. Treatment in all three therapeutic arms (SC, IV, and MADDD) was administered once weekly for 6 weeks. Treatment efficacy was measured once a week according to tumor volume using ultrasound. In addition, calipers were used to assess tumor volume. Animals implanted with the device demonstrated no signs of distress or discomfort, neither local nor systemic symptoms of inflammation and infection. Using an independent sample t-test, the tumor growth rate of the treated tumors was significant when compared to the control. Post hoc Tukey HSD test results showed that the mean tumor growth rate of our device cohort was significantly lower than SC and control cohorts. Moreover, IV cohort showed slight reduction in mean tumor growth rates than the ones from the device cohort, however, there was no statistical significance in tumor growth rate between these two cohorts. Furthermore, immunohistochemistry demonstrated an increased cellular apoptosis in the MADDD treated tumors and a decreased proliferation when compared to the other cohorts. In addition, IV cohort showed increased treatment side effects (weight loss) when compared to the device cohort. Finally, MADDD showed minimal expression of CD45 comparable to the control cohort, suggesting no signs of chronic inflammation. In conclusion, this study showed for the first time that MADDD, clearly suppressed tumor growth in local prostate cancer tumors. This could potentially be a novel clinical treatment approach for localized prostate cancer. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keyes, Mira, E-mail: mkeyes@bccancer.bc.ca; Miller, Stacy; Pickles, Tom
2014-11-01
Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ({sup 125}I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier andmore » log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer follow-up (27% RTOG 2 and 10% RTOG 3 at 13 years), symptoms resolve relatively quickly; between 5 and 13 years' follow-up, >90% of patients have minimal urinary toxicity. Refining patient selection criteria, planning, and treatment delivery may further reduce toxicity.« less
Würschmidt, Florian; Petersen, Cordula; Wahl, Andreas; Dahle, Jörg; Kretschmer, Matthias
2011-05-01
At present there is no consensus on irradiation treatment volumes for intermediate to high-risk primary cancers or recurrent disease. Conventional imaging modalities, such as CT, MRI and transrectal ultrasound, are considered suboptimal for treatment decisions. Choline-PET/CT might be considered as the imaging modality in radiooncology to select and delineate clinical target volumes extending the prostate gland or prostate fossa. In conjunction with intensity modulated radiotherapy (IMRT) and imaged guided radiotherapy (IGRT), it might offer the opportunity of dose escalation to selected sites while avoiding unnecessary irradiation of healthy tissues. Twenty-six patients with primary (n = 7) or recurrent (n = 19) prostate cancer received Choline-PET/CT planned 3D conformal or intensity modulated radiotherapy. The median age of the patients was 65 yrs (range 45 to 78 yrs). PET/CT-scans with F18-fluoroethylcholine (FEC) were performed on a combined PET/CT-scanner equipped for radiation therapy planning. The majority of patients had intermediate to high risk prostate cancer. All patients received 3D conformal or intensity modulated and imaged guided radiotherapy with megavoltage cone beam CT. The median dose to primary tumours was 75.6 Gy and to FEC-positive recurrent lymph nodal sites 66,6 Gy. The median follow-up time was 28.8 months. The mean SUV(max) in primary cancer was 5,97 in the prostate gland and 3,2 in pelvic lymph nodes. Patients with recurrent cancer had a mean SUV(max) of 4,38. Two patients had negative PET/CT scans. At 28 months the overall survival rate is 94%. Biochemical relapse free survival is 83% for primary cancer and 49% for recurrent tumours. Distant disease free survival is 100% and 75% for primary and recurrent cancer, respectively. Acute normal tissue toxicity was mild in 85% and moderate (grade 2) in 15%. No or mild late side effects were observed in the majority of patients (84%). One patient had a severe bladder shrinkage (grade 4) after a previous treatment with TUR of the prostate and seed implantation. FEC-PET/CT planning could be helpful in dose escalation to lymph nodal sites of prostate cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Racine, E; Hautvast, G; Binnekamp, D
Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc wasmore » carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.« less
Surface coating for prevention of metallic seed migration in tissues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Hyunseok; Park, Jong In; Lee, Won Seok
Purpose: In radiotherapy, metallic implants often detach from their deposited sites and migrate to other locations. This undesirable migration could cause inadequate dose coverage for permanent brachytherapy and difficulties in image-guided radiation delivery for patients. To prevent migration of implanted seeds, the authors propose a potential strategy to use a biocompatible and tissue-adhesive material called polydopamine. Methods: In this study, nonradioactive dummy seeds that have the same geometry and composition as commercial I-125 seeds were coated in polydopamine. Using scanning electron microscopy and x-ray photoelectron spectroscopy, the surface of the polydopamine-coated and noncoated seeds was characterized. The detachment stress betweenmore » the two types of seeds and the tissue was measured. The efficacy of polydopamine-coated seed was investigated through in vitro migration tests by tracing the seed location after tissue implantation and shaking for given times. The cytotoxicity of the polydopamine coating was also evaluated. Results: The results of the coating characterization have shown that polydopamine was successfully coated on the surface of the seeds. In the adhesion test, the polydopamine-coated seeds had 2.1-fold greater detachment stress than noncoated seeds. From the in vitro test, it was determined that the polydopamine-coated seed migrated shorter distances than the noncoated seed. This difference was increased with a greater length of time after implantation. Conclusions: The authors suggest that polydopamine coating is an effective technique to prevent migration of implanted seeds, especially for permanent prostate brachytherapy.« less
NiP black: vers l'utilisation d'un traitement plus noir que noir contre la lumière parasite
NASA Astrophysics Data System (ADS)
Mazuray, L.; Petilon, JF.
2017-11-01
Le NiP black est un alliage de Nickel-Phosphore poreux présentant un coefficient d'absorption exceptionnel de 0.998, permettant un gain en diffusion d'un facteur 10 à 20 par rapport à la meilleure des peintures noires utilisée sur les baffles et montures des instruments d'optique. L'industrialisation de ce procédé fait l'objet d'une collaboration entre le CNES, SODERN et MMS afin de répondre au mieux aux exigences des différents instruments spatiaux. Le faible niveau de diffusion des baffles et des montures des instruments optiques est un élément clé d'un faible niveau de lumière parasite et par voie de conséquence, des performances en détection, imagerie et d'analyse. Les essais réalisés en 98 et 99 sur des visières de senseurs solaires haute précision implantés sur les plate-formes telecom MMS ont confirmé les excellentes performances du senseur obtenues grâce à ce traitement. NiP Black s'incrit dans une démarche générale MMS d'amélioration des performances en lumière parasite des instruments optiques. Il est proposé de présenter le NiP Black et les performances réalisées sur des visières de senseurs implantés sur les plate-formes MMS, ainsi que son potentiel à venir.
Landry, Guillaume; Reniers, Brigitte; Pignol, Jean-Philippe; Beaulieu, Luc; Verhaegen, Frank
2011-03-01
The goal of this work is to compare D(m,m) (radiation transported in medium; dose scored in medium) and D(w,m) (radiation transported in medium; dose scored in water) obtained from Monte Carlo (MC) simulations for a subset of human tissues of interest in low energy photon brachytherapy. Using low dose rate seeds and an electronic brachytherapy source (EBS), the authors quantify the large cavity theory conversion factors required. The authors also assess whether ap plying large cavity theory utilizing the sources' initial photon spectra and average photon energy induces errors related to spatial spectral variations. First, ideal spherical geometries were investigated, followed by clinical brachytherapy LDR seed implants for breast and prostate cancer patients. Two types of dose calculations are performed with the GEANT4 MC code. (1) For several human tissues, dose profiles are obtained in spherical geometries centered on four types of low energy brachytherapy sources: 125I, 103Pd, and 131Cs seeds, as well as an EBS operating at 50 kV. Ratios of D(w,m) over D(m,m) are evaluated in the 0-6 cm range. In addition to mean tissue composition, compositions corresponding to one standard deviation from the mean are also studied. (2) Four clinical breast (using 103Pd) and prostate (using 125I) brachytherapy seed implants are considered. MC dose calculations are performed based on postimplant CT scans using prostate and breast tissue compositions. PTV D90 values are compared for D(w,m) and D(m,m). (1) Differences (D(w,m)/D(m,m)-1) of -3% to 70% are observed for the investigated tissues. For a given tissue, D(w,m)/D(m,m) is similar for all sources within 4% and does not vary more than 2% with distance due to very moderate spectral shifts. Variations of tissue composition about the assumed mean composition influence the conversion factors up to 38%. (2) The ratio of D90(w,m) over D90(m,m) for clinical implants matches D(w,m)/D(m,m) at 1 cm from the single point sources, Given the small variation with distance, using conversion factors based on the emitted photon spectrum (or its mean energy) of a given source introduces minimal error. The large differences observed between scoring schemes underline the need for guidelines on choice of media for dose reporting. Providing such guidelines is beyond the scope of this work.
Snead, Margaret Christine; Wiener, Jeffrey; Ewumi, Sinmisola; Phillips, Christi; Flowers, Lisa; Hylton-Kong, Tina; Medley-Singh, Natalie; Legardy-Williams, Jennifer; Costenbader, Elizabeth; Papp, John; Warner, Lee; Black, Carolyn; Kourtis, Athena P
2017-01-01
Background There is limited information on rates of STIs in Jamaica due to syndromic management and limited aetiological surveillance. We examined the prevalence of Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) and Trichomonas vaginalis (TV) and characteristics associated with STIs among sexually active women who participated in a randomised trial of a progestin implant initiation in Jamaica (the Sino-Implant Study (SIS)). Methods SIS was a randomised trial conducted in Kingston, Jamaica, from 2012 to 2014 to evaluate whether initiation of the Sino-Implant (II) led to more unprotected sex among women ages 18–44 years. Data collected included self-reported demographic, sexual behaviour information; and vaginal swabs collected at baseline, 1-month and 3-month follow-up visits for a biomarker of recent semen exposure (prostate-specific antigen (PSA)) and for STIs. We examined associations between STIs and PSA, demographics, sexual behaviour and insertion of an implant, with a repeated-measures analysis using generalised estimating equations (SAS Institute, V.9.3). Results Remnant vaginal swabs from 254 of 414 study participants were tested for STIs. At baseline, 29% of participants tested for STIs (n=247) had laboratory-confirmed CT, 5% NG, 23% TV and 45% any STI. In a repeated-measures analysis adjusted for study arm (immediate vs delayed implant insertion), those with PSA detected did not have an increased prevalence of any STI (prevalence ratio (PR)=1.04 (95% CI 0.89 to 1.21)), whereas prevalence decreased for each 1-year increase in age (PR=0.98 (95% CI 0.97 to 0.99)). Immediate implant insertion was not associated with increases in any STI in subsequent visits (PR=1.09 (95% CI 0.94 to 1.27)). Conclusions Although the prevalence of laboratory-confirmed STIs was high, the immediate initiation of a contraceptive implant was not associated with higher STI prevalence rates over 3 months. Trial registration number NCT01684358. PMID:28476913
Disease-specific survival following the brachytherapy management of prostate cancer.
Stock, Richard G; Cesaretti, Jamie A; Stone, Nelson N
2006-03-01
To determine disease-specific survival (DSS) and associated predictive factors after prostate brachytherapy. A total of 1561 patients underwent brachytherapy for prostate cancer from 1990 to 2004 (median follow-up, 3.8 years). Treatment included brachytherapy alone (n = 634), brachytherapy and hormonal therapy (n = 420), and implant and external beam therapy (n = 507). The DSS and overall survival rates at 10 years were 96% and 74%, respectively. Gleason score significantly impacted DSS, with 10-year rates of 98%, 91%, and 92% for scores of < or = 6, 7, and > or = 8, respectively (p < 0.0001). Multivariate analysis revealed that PSA status after treatment had the most significant effect on DSS. Ten-year DSS rates were 100%, 52%, and 98%, respectively for patients without PSA failure (n = 1430), failure with a doubling time (DT) < or = 10 months (n = 64), and failure with a DT > 10 months (n = 67), respectively (p < 0.0001). In patients with PSA failure, DSS rates were 30%, 67%, and 98%, for those with DT < or = 6 months, > 6-10 months, and > 10 months, respectively (p < 0.0001). The 10-year DSS rate supports the efficacy of brachytherapy. Patients dying with disease within 10 years after treatment harbor inherently aggressive cancer with high Gleason scores and short DT.
Aoki, Yoshitaka; Ito, Hideaki; Miwa, Yoshiji; Akino, Hironobu; Shioura, Hiroki; Kimura, Hirohiko; Yokoyama, Osamu
2014-01-01
Purpose. To assess changes in lower urinary tract symptoms (LUTS) within 1 year after brachytherapy in patients receiving alpha 1-adrenoceptor antagonists. Methods. We retrospectively evaluated 116 patients who underwent 125I prostate brachytherapy in our institute. Seventy-one patients were treated with a combination of external beam radiation therapy and brachytherapy. Alpha 1-adrenoceptor antagonists were prescribed to all patients after brachytherapy. International Prostate Symptom Score (IPSS) forms and postvoid residual urine volume were recorded at all follow-up visits. Results. Forty-nine patients were given tamsulosin hydrochloride, 32 were given silodosin hydrochloride, and 35 were given naftopidil for up to 6 months after seed implantation. Patients given tamsulosin or naftopidil tended to show a higher peak IPSS and slower recovery to baseline values than those given silodosin. The patients given naftopidil showed an insufficient recovery in storage symptoms in naftopidil group in comparison with tamsulosin group at 3 months and with silodosin group at 6 and 9 months. Conclusions. In the management of LUT after brachytherapy, silodosin may provide a more favorable improvement. Silodosin and tamsulosin may have an advantage in improving not only voiding but also storage lower urinary tract symptoms after brachytherapy. PMID:25006516
[Bladder neck sclerosis following prostate surgery : Which therapy when?
Rassweiler, J J; Weiss, H; Heinze, A; Elmussareh, M; Fiedler, M; Goezen, A S
2017-09-01
Secondary bladder neck sclerosis represents one of the more frequent complications following endoscopic, open, and other forms of minimally invasive prostate surgery. Therapeutic decisions depend on the type of previous intervention (e.g., radical prostatectomy, TURP, HoLEP, radiotherapy, HIFU) and on associated complications (e.g., incontinence, fistula). Primary treatment in most cases represents an endoscopic bilateral incision. No specific advantages of any type of the applied energy (i.e., mono-/bipolar HF current, cold incision, holmium/thulium YAG laser) could be documented. Adjuvant measures such as injection of corticosteroids or mitomycin C have not been helpful in clinical routine. In case of first recurrence, a transurethral monopolar or bipolar resection can usually be performed. Recently, the ablation of the scared tissue using bipolar vaporization has been recommended providing slightly better long-term results. Thereafter, surgical reconstruction is strongly recommended using an open, laparoscopic, or robot-assisted approach. Depending on the extent of the bladder neck sclerosis and the underlying prostate surgery, a Y-V/T-plasty, urethral reanastomosis, or even a radical prostatectomy with new urethravesical anastomosis should be performed. Stent implantation should be reserved for patients who are not suitable for surgery. The final palliative measure is a cystectomy with urinary diversion or a (continent) cystostomy.
Detection and correction of patient movement in prostate brachytherapy seed reconstruction
NASA Astrophysics Data System (ADS)
Lam, Steve T.; Cho, Paul S.; Marks, Robert J., II; Narayanan, Sreeram
2005-05-01
Intraoperative dosimetry of prostate brachytherapy can help optimize the dose distribution and potentially improve clinical outcome. Evaluation of dose distribution during the seed implant procedure requires the knowledge of 3D seed coordinates. Fluoroscopy-based seed localization is a viable option. From three x-ray projections obtained at different gantry angles, 3D seed positions can be determined. However, when local anaesthesia is used for prostate brachytherapy, the patient movement during fluoroscopy image capture becomes a practical problem. If uncorrected, the errors introduced by patient motion between image captures would cause seed mismatches. Subsequently, the seed reconstruction algorithm would either fail to reconstruct or yield erroneous results. We have developed an algorithm that permits detection and correction of patient movement that may occur between fluoroscopy image captures. The patient movement is decomposed into translational shifts along the tabletop and rotation about an axis perpendicular to the tabletop. The property of spatial invariance of the co-planar imaging geometry is used for lateral movement correction. Cranio-caudal movement is corrected by analysing the perspective invariance along the x-ray axis. Rotation is estimated by an iterative method. The method can detect and correct for the range of patient movement commonly seen in the clinical environment. The algorithm has been implemented for routine clinical use as the preprocessing step for seed reconstruction.
Cystostomie percutanée à la pince de Kelly: indications, technique et résultats
Diabaté, Ibrahima; Ouédraogo, Bouréima; Sow, Ibrahima; Bâ, Aliou
2015-01-01
Introduction La dérivation urinaire sus-pubienne est pratiquée dans différentes circonstances. Cette étude vise à décrire la technique de cystostomie percutanée (CPC) pratiquée à l'aide d'une pince de Kelly pour la pose d'une sonde de Foley, à définir les indications de cette technique et à rapporter les résultats. Méthodes Du 1er janvier 2005 au 31 décembre 2014, il a été réalisé 194 CPC à la pince de Kelly dans notre service, en urgence, sous anesthésie locale, chez des patients en rétention vésicale. Cette technique, dérivée de la cystostomie par ponction au trocart vise à placer dans la vessie une sonde de Foley après incision cutanée et aponévrotique (de 1 cm sur la ligne médiane, à 1,5 - 2 cm au-dessus de la symphyse pubienne) et la ponction vésicale à la pince de Kelly à travers cette incision. Résultats Les 194 patients étaient tous de sexe masculin, âgés en moyenne de 50 ans ± 21 (extrêmes de 17 ans et 86 ans). Les pathologies à l'origine des rétentions vésicales étaient: les rétrécissements urétraux (n=119), les hypertrophies bénignes de la prostate (n=47), les cancers de prostate (n=21), les traumatismes de l'urètre (n=7). Tous les patients ont été opérés avec succès par cette méthode et les suites ont été simples. Le temps de réalisation était de 6 minutes ± 1. Les sondes de Foley mises en place étaient de charrière 16 (n=59), charrière 18 (n=116) et charrière 20 (n=19). La cicatrisation du trajet de la CPC après l'ablation de la sonde de Foley n'a posée aucun problème chez 146 patients suivis, les 48 autres ayant été perdus de vue. Conclusion La CPC à la pince de Kelly est une technique simple, rapide et pas onéreuse. Ses indications sont les mêmes que pour toute CPC et elle représente une alternative à la cystostomie par chirurgie ouverte. PMID:26893798
Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes.
Erçalık, Nimet Yeşim; İmamoğlu, Serhat
2018-01-01
To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. The mean follow-up duration was 11.7 ± 5.5 (range, 6-23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg ( p =0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 ( p =0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.
Sano, Ichiya; Tanito, Masaki; Uchida, Koji; Katsube, Takashi; Kitagaki, Hajime; Ohira, Akihiro
2015-01-01
To evaluate ocular fluid filtration and endplate positioning in glaucomatous eyes with long-tube glaucoma drainage devices (GDDs) using magnetic resonance imaging (MRI) and the effects of various factors on postoperative intraocular pressure (IOP). This observational case series included 27 consecutive glaucomatous eyes (18 men, 7 women; mean age ± standard error, 63.0±2.0 years) who underwent GDD implantation (n = 8 Ahmed Glaucoma Valves [AGV] and n = 19 Baerveldt Glaucoma Implants [BGI]). Tubes were inserted into the pars plana in 23 eyes and anterior chamber in 4 eyes. Six months postoperatively, high-resolution orbital images were obtained using 3-Tesla MRI with head-array coils, and the filtering bleb volume, bleb height, and distances between the anterior endplate edge and corneal center or limbus or between the endplate and orbital wall were measured. In MR images obtained by three-dimensional fast imaging employing steady-state acquisition (3D-FIESTA) sequences, the shunt endplate was identified as low-intensity signal, and the filtering bleb was identified as high-intensity signals above and below the endplate in all eyes. The 6-month-postoperative IOP level was correlated negatively with bleb volume (r = -0.4510, P = 0.0182) and bleb height (r = -0.3954, P = 0.0412). The postoperative IOP was significantly (P = 0.0026) lower in BGI-implanted eyes (12.2±0.7 mmHg) than AGV-implanted eyes (16.7±1.2 mmHg); bleb volume was significantly (P = 0.0093) larger in BGI-implanted eyes (478.8±84.2 mm3) than AGV-implanted eyes (161.1±52.3 mm3). Other parameters did not differ. The presence of intraorbital/periocular accumulation of ocular fluid affects postoperative IOP levels in eyes implanted with long-tube GDDs. Larger filtering blebs after BGI than AGI implantations explain lower postoperative IOP levels achieved with BGI than AGV. The findings will contribute to better understanding of IOP reducing mechanism of long-tube GDDs.
Roy, Avik Kumar; Senthil, Sirisha
2015-01-01
Glaucoma in aphakia is a major long term complication following congenital cataract surgery. Implantation of glaucoma drainage device provides an effective approach to manage refractory paediatric glaucoma. However implant surgery in young individuals is not free of complications. The prompt detection and management of tube erosion is of utmost importance to prevent devastating sequel of endophthalmitis. Implantation cyst following repair of tube erosion has not been reported so far. This case illustrates the rare occurrence of inclusion cyst following repair of tube erosion, the possible causes and its consequences. A 2-year-old child with aphakia developed intractable glaucoma. Following a failed glaucoma filtering surgery he underwent sequential Ahmed Glaucoma Valve implantation in both the eyes. Six weeks following right eye surgery, the child presented with conjunctival erosion overlying the tube, which was treated with scleral patch graft and conjunctival advancement. One month after the repair of tube erosion, the child presented with implantation cyst under the scleral patch graft, which was treated by drainage with a 29G needle. The child presented with endophthalmitis of his right eye following an episode of bilateral conjunctivitis. This was managed by an emergency pars plana vitrectomy, intraocular antibiotics and tube excision. At the last follow up visit, the IOP was 20 mmHg with 2 topical antiglaucoma medications in the right eye following a trans scleral photocoagulation. Lifelong careful follow-up of paediatric eyes with implant surgery is mandatory to look for complication such as tube erosion. It is important to place additional sutures to secure the patch graft during implantation of glaucoma drainage devices in children to prevent graft displacement and consequent tube erosion. During repair of tube erosion, it is crucial to remove all the conjunctival epithelium around the tube, thus not to incorporate epithelial tissue within the surgical wound.
Treatment planning: implant-supported partial overdentures.
Chee, Winston W L
2005-04-01
When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the implant-supported overdenture has several advantages, some in common with a removable partial denture.
Dauchy, Robert T; Hoffman, Aaron E; Wren-Dail, Melissa A; Hanifin, John P; Warfield, Benjamin; Brainard, George C; Xiang, Shulin; Yuan, Lin; Hill, Steven M; Belancio, Victoria P; Dauchy, Erin M; Smith, Kara; Blask, David E
2015-01-01
Light controls pineal melatonin production and temporally coordinates circadian rhythms of metabolism and physiology in normal and neoplastic tissues. We previously showed that peak circulating nocturnal melatonin levels were 7-fold higher after daytime spectral transmittance of white light through blue-tinted (compared with clear) rodent cages. Here, we tested the hypothesis that daytime blue-light amplification of nocturnal melatonin enhances the inhibition of metabolism, signaling activity, and growth of prostate cancer xenografts. Compared with male nude rats housed in clear cages under a 12:12-h light:dark cycle, rats in blue-tinted cages (with increased transmittance of 462–484 nm and decreased red light greater than 640 nm) evinced over 6-fold higher peak plasma melatonin levels at middark phase (time, 2400), whereas midlight-phase levels (1200) were low (less than 3 pg/mL) in both groups. Circadian rhythms of arterial plasma levels of linoleic acid, glucose, lactic acid, pO2, pCO2, insulin, leptin, and corticosterone were disrupted in rats in blue cages as compared with the corresponding entrained rhythms in clear-caged rats. After implantation with tissue-isolated PC3 human prostate cancer xenografts, tumor latency-to-onset of growth and growth rates were markedly delayed, and tumor cAMP levels, uptake–metabolism of linoleic acid, aerobic glycolysis (Warburg effect), and growth signaling activities were reduced in rats in blue compared with clear cages. These data show that the amplification of nighttime melatonin levels by exposing nude rats to blue light during the daytime significantly reduces human prostate cancer metabolic, signaling, and proliferative activities. PMID:26678364
Dauchy, Robert T; Hoffman, Aaron E; Wren-Dail, Melissa A; Hanifin, John P; Warfield, Benjamin; Brainard, George C; Xiang, Shulin; Yuan, Lin; Hill, Steven M; Belancio, Victoria P; Dauchy, Erin M; Smith, Kara; Blask, David E
2015-12-01
Light controls pineal melatonin production and temporally coordinates circadian rhythms of metabolism and physiology in normal and neoplastic tissues. We previously showed that peak circulating nocturnal melatonin levels were 7-fold higher after daytime spectral transmittance of white light through blue-tinted (compared with clear) rodent cages. Here, we tested the hypothesis that daytime blue-light amplification of nocturnal melatonin enhances the inhibition of metabolism, signaling activity, and growth of prostate cancer xenografts. Compared with male nude rats housed in clear cages under a 12:12-h light:dark cycle, rats in blue-tinted cages (with increased transmittance of 462-484 nm and decreased red light greater than 640 nm) evinced over 6-fold higher peak plasma melatonin levels at middark phase (time, 2400), whereas midlight-phase levels (1200) were low (less than 3 pg/mL) in both groups. Circadian rhythms of arterial plasma levels of linoleic acid, glucose, lactic acid, pO2, pCO2, insulin, leptin, and corticosterone were disrupted in rats in blue cages as compared with the corresponding entrained rhythms in clear-caged rats. After implantation with tissue-isolated PC3 human prostate cancer xenografts, tumor latency-to-onset of growth and growth rates were markedly delayed, and tumor cAMP levels, uptake-metabolism of linoleic acid, aerobic glycolysis (Warburg effect), and growth signaling activities were reduced in rats in blue compared with clear cages. These data show that the amplification of nighttime melatonin levels by exposing nude rats to blue light during the daytime significantly reduces human prostate cancer metabolic, signaling, and proliferative activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Tze Yee
Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisitionmore » with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.« less
Sexual healing in patients with prostate cancer on hormone therapy.
Schover, Leslie R
2015-01-01
Since prostate cancer becomes more common with age, at least one-third of men have sexual problems at diagnosis. All localized treatments for prostate cancer greatly increase the prevalence of sexual dysfunction, which include loss of desire, erectile dysfunction, and changes in orgasm. Even men on active surveillance have a higher rate of problems than matched peers without prostate cancer. However, men given androgen deprivation therapy (ADT) have the worst rates of sexual dysfunction. Even after 3 to 4 months of ADT, men's desire for sex is decreased and irreversible damage may occur to the erectile tissue in the penis. Erections do not recover in about one-half of men, even if ADT is discontinued. Although intermittent ADT allows some recovery of sexual function, serum testosterone requires 9 to 12 months off ADT to recover. Again, one-half of men have permanent erectile dysfunction. If ADT causes atrophy of the erectile tissue, blood leaks out of the venous system during erection. This syndrome is difficult to treat except with surgery to implant a penile prosthesis. Despite the high rate of sexual problems in men on ADT, a small group stays sexually active and is able to have reliable erections. To improve men's sexual satisfaction on ADT, it may be important to educate them about getting extra mental and physical sexual stimulation, as well as using penile rehabilitation during hormone therapy. Information on reaching orgasm and coping with problems such as dry orgasm, pain with orgasm, and urinary incontinence during sex also should be provided.
Endothelial-to-Osteoblast Conversion Generates Osteoblastic Metastasis of Prostate Cancer.
Lin, Song-Chang; Lee, Yu-Chen; Yu, Guoyu; Cheng, Chien-Jui; Zhou, Xin; Chu, Khoi; Murshed, Monzur; Le, Nhat-Tu; Baseler, Laura; Abe, Jun-Ichi; Fujiwara, Keigi; deCrombrugghe, Benoit; Logothetis, Christopher J; Gallick, Gary E; Yu-Lee, Li-Yuan; Maity, Sankar N; Lin, Sue-Hwa
2017-06-05
Prostate cancer (PCa) bone metastasis is frequently associated with bone-forming lesions, but the source of the osteoblastic lesions remains unclear. We show that the tumor-induced bone derives partly from tumor-associated endothelial cells that have undergone endothelial-to-osteoblast (EC-to-OSB) conversion. The tumor-associated osteoblasts in PCa bone metastasis specimens and patient-derived xenografts (PDXs) were found to co-express endothelial marker Tie-2. BMP4, identified in PDX-conditioned medium, promoted EC-to-OSB conversion of 2H11 endothelial cells. BMP4 overexpression in non-osteogenic C4-2b PCa cells led to ectopic bone formation under subcutaneous implantation. Tumor-induced bone was reduced in trigenic mice (Tie2 cre /Osx f/f /SCID) with endothelial-specific deletion of osteoblast cell-fate determinant OSX compared with bigenic mice (Osx f/f /SCID). Thus, tumor-induced EC-to-OSB conversion is one mechanism that leads to osteoblastic bone metastasis of PCa. Copyright © 2017 Elsevier Inc. All rights reserved.
Henderson, Alastair; Laing, Robert W; Langley, Stephen E M
2002-01-01
Assessment of the Spanner, a new temporary urethral stent to relieve bladder outflow obstruction and urinary symptoms after brachytherapy. Five patients with unusually severe urinary morbidity after (125)I brachytherapy were recruited. The mean time after implant was 40 days (range 25-90). Spanner intraprostatic stents were introduced using topical anesthetic without complication. All patients were able to void spontaneously with no post-void residual volume of urine. The flow rates increased in all cases (p=0.03) and the International Prostate Symptom Scores were significantly improved after stent insertion in all patients (p=0.03). All patients experienced some degree of pain or dysuria during stent use. Bladder outflow obstruction was effectively treated with the Spanner intraprostatic stent, however pain limited the use of the device in the early post-brachytherapy patient group. Pharmacotherapy, stent design modification, or smaller stent diameter may increase the utility of stents after brachytherapy.
SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giaddui, T; Hardin, M; To, D
Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seedsmore » and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.« less
Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank
2002-06-01
To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose <93 Gy (58 patients) and high-dose biologically effective dose >93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p <0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p = 0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.
NASA Astrophysics Data System (ADS)
O'Shea, Tuathan P.; Garcia, Leo J.; Rosser, Karen E.; Harris, Emma J.; Evans, Philip M.; Bamber, Jeffrey C.
2014-04-01
This study investigates the use of a mechanically-swept 3D ultrasound (3D-US) probe for soft-tissue displacement monitoring during prostate irradiation, with emphasis on quantifying the accuracy relative to CyberKnife® x-ray fiducial tracking. An US phantom, implanted with x-ray fiducial markers was placed on a motion platform and translated in 3D using five real prostate motion traces acquired using the Calypso system. Motion traces were representative of all types of motion as classified by studying Calypso data for 22 patients. The phantom was imaged using a 3D swept linear-array probe (to mimic trans-perineal imaging) and, subsequently, the kV x-ray imaging system on CyberKnife. A 3D cross-correlation block-matching algorithm was used to track speckle in the ultrasound data. Fiducial and US data were each compared with known phantom displacement. Trans-perineal 3D-US imaging could track superior-inferior (SI) and anterior-posterior (AP) motion to ≤0.81 mm root-mean-square error (RMSE) at a 1.7 Hz volume rate. The maximum kV x-ray tracking RMSE was 0.74 mm, however the prostate motion was sampled at a significantly lower imaging rate (mean: 0.04 Hz). Initial elevational (right-left RL) US displacement estimates showed reduced accuracy but could be improved (RMSE <2.0 mm) using a correlation threshold in the ultrasound tracking code to remove erroneous inter-volume displacement estimates. Mechanically-swept 3D-US can track the major components of intra-fraction prostate motion accurately but exhibits some limitations. The largest US RMSE was for elevational (RL) motion. For the AP and SI axes, accuracy was sub-millimetre. It may be feasible to track prostate motion in 2D only. 3D-US also has the potential to improve high tracking accuracy for all motion types. It would be advisable to use US in conjunction with a small (˜2.0 mm) centre-of-mass displacement threshold in which case it would be possible to take full advantage of the accuracy and high imaging rate capability.
Koontz, Bridget F; Chino, Junzo; Lee, W Robert; Hahn, Carol A; Buckley, Niall; Huang, Samuel; Kim, Jay; Reagan, Robert; Joyner, Raymond; Anscher, Mitchell S
2009-01-01
Dose escalation has been shown beneficial in prostate cancer. Brachytherapy (BT) provides an opportunity for dose escalation beyond what can be safely delivered using only teletherapy methods. The purpose of this study was to determine cancer control and morbidity of external beam radiation therapy (EBRT) plus low-dose-rate (LDR) BT boost in patients with prostate cancer treated at Duke University Health System. Between June 1997 and August 2007, 199 patients were consecutively treated at our facility with 46Gy EBRT followed by 100Gy palladium-103 ((103)Pd) or 120Gy iodine-125 ((125)I) LDR prostate implant. Treatment characteristics and followup data were retrospectively analyzed. Intermediate risk was defined as T2b-c, Gleason score 7 (GS 7), or prostate-specific antigen (PSA) of 10.1-19.9ng/mL. High risk was defined as GS 8-10, PSA>20, T3+, or two intermediate risk factors. The Radiation Therapy Oncology Group toxicity scale was used to report morbidity for gastrointestinal (GI) and genitourinary (GU) effects. PSA recurrence was defined as nadir+2ng/mL. Median followup was 4.2 years for all patients, 4.8 years for high-risk patients. Risk categories were as follows: 20% low risk, 47% intermediate risk, and 33% high risk. Forty five percent of patients received adjuvant androgen deprivation therapy (ADT). The median length of time since end of ADT to last followup was 2.7 years in all patients, 2.0 years for high-risk patients. Five-year biochemical relapse-free survival was 87% for all, 81% for high-risk patients. PSA control was similar at 92% for all and 86% for high-risk patients. Five-year actuarial risk of any and Grade 3 late GI morbidity was 38% and 7% respectively, and any and Grade 3 late GU morbidity was 21% and 3%, respectively. There were no significant differences in risk of Grade 2+GI or GU morbidity with choice of isotope. EBRT plus LDR BT has acceptable morbidity and, with 5-year followup, provides excellent cancer control even in high-risk patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Trofimov, A; Sharp, G C
2015-06-15
Purpose: To investigate the effects of interfractional anatomy and setup variations on plans with anterior-oblique vs. lateral beams for prostate cancer pencil beam scanning (PBS) and passive scattered (PS) proton therapy. Methods: Six patients with low/intermediate risk prostate cancer treated with PS proton therapy at our institution were selected. All patients underwent weekly verification CT scans. Implanted fiducials were used for localization, and endorectal balloons for prostate immobilization. New PBS plans with lateral beams, as well as PBS and PS plans with anterior-oblique beams (±35 deg) were created. PBS plans used two different spot sizes: ∼10mm (large) and ∼5mm (medium)more » sigma at 25cm range and optimized as single-field-uniform-dose with ∼8% non-uniformity. No range uncertainty margins were applied in PBS plans to maximize rectal sparing. Field-specific apertures were used when planning with large spots to sharpen the penumbrae. The planned dose was recomputed on each weekly CT with fiducials aligned to the simulation CT, scaled and accumulated via deformable image registration. Results: The dose volume analysis showed that although difference between planned and accumulated dose remains negligible for plans with conventional lateral beams using both PS and PBS, this is not the case for plans with anterior beams. The target coverage in anterior plans was largely degraded due to the variations in the beam path length and the absence of range margins. The average prostate D95 was reduced by 7.5/15.9% (using PS/PBS) after accumulation for anterior plans, compared with 0/0.4% for lateral plans. The average mean dose in organs-at-risk decreased by 1% for lateral and 2% for anterior plans, similarly for PS and PBS. Spot size did not affect the dose changes. Conclusion: Prostate plans using anterior beams may undergo clinically relevant interfractional dose degradation. Corrective strategies guided by in-vivo range measurements should be studied before clinical application of this technique.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, Maryam, E-mail: mmoteabbed@partners.org; Trofimov, Alexei; Sharp, Gregory C.
Purpose: To quantify and compare the impact of interfractional setup and anatomic variations on proton therapy (PT) and intensity modulated radiation therapy (IMRT) for prostate cancer. Methods and Materials: Twenty patients with low-risk or intermediate-risk prostate cancer randomized to receive passive-scattering PT (n=10) and IMRT (n=10) were selected. For both modalities, clinical treatment plans included 50.4 Gy(RBE) to prostate and proximal seminal vesicles, and prostate-only boost to 79.2 Gy(RBE) in 1.8 Gy(RBE) per fraction. Implanted fiducials were used for prostate localization and endorectal balloons were used for immobilization. Patients in PT and IMRT arms received weekly computed tomography (CT) and cone beam CTmore » (CBCT) scans, respectively. The planned dose was recalculated on each weekly image, scaled, and mapped onto the planning CT using deformable registration. The resulting accumulated dose distribution over the entire treatment course was compared with the planned dose using dose-volume histogram (DVH) and γ analysis. Results: The target conformity index remained acceptable after accumulation. The largest decrease in the average prostate D{sub 98} was 2.2 and 0.7 Gy for PT and IMRT, respectively. On average, the mean dose to bladder increased by 3.26 ± 7.51 Gy and 1.97 ± 6.84 Gy for PT and IMRT, respectively. These values were 0.74 ± 2.37 and 0.56 ± 1.90 for rectum. Differences between changes in DVH indices were not statistically significant between modalities. All volume indices remained within the protocol tolerances after accumulation. The average pass rate for the γ analysis, assuming tolerances of 3 mm and 3%, for clinical target volume, bladder, rectum, and whole patient for PT/IMRT were 100/100, 92.6/99, 99.2/100, and 97.2/99.4, respectively. Conclusion: The differences in target coverage and organs at risk dose deviations for PT and IMRT were not statistically significant under the guidelines of this protocol.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hathout, Lara; Folkert, Michael R.; Kollmeier, Marisa A.
2014-10-01
Purpose: To identify an anatomic structure predictive for acute (AUT) and late (LUT) urinary toxicity in patients with prostate cancer treated with low-dose-rate brachytherapy (LDR) with or without external beam radiation therapy (EBRT). Methods and Materials: From July 2002 to January 2013, 927 patients with prostate cancer (median age, 66 years) underwent LDR brachytherapy with Iodine 125 (n=753) or Palladium 103 (n=174) as definitive treatment (n=478) and as a boost (n=449) followed by supplemental EBRT (median dose, 50.4 Gy). Structures contoured on the computed tomographic (CT) scan on day 0 after implantation included prostate, urethra, bladder, and the bladder neck, defined asmore » 5 mm around the urethra between the catheter balloon and the prostatic urethra. AUT and LUT were assessed with the Common Terminology Criteria for Adverse Events, version4. Clinical and dosimetric factors associated with AUT and LUT were analyzed with Cox regression and receiver operating characteristic analysis to calculate area under the receiver operator curve (ROC) (AUC). Results: Grade ≥2 AUT and grade ≥2 LUT occurred in 520 patients (56%) and 154 patients (20%), respectively. No grade 4 toxicities were observed. Bladder neck D2cc retained a significant association with AUT (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.03-1.04; P<.0001) and LUT (HR, 1.01; 95% CI, 1.00-1.03; P=.014) on multivariable analysis. In a comparison of bladder neck with the standard dosimetric variables by use of ROC analysis (prostate V100 >90%, D90 >100%, V150 >60%, urethra D20 >130%), bladder neck D2cc >50% was shown to have the strongest prognostic power for AUT (AUC, 0.697; P<.0001) and LUT (AUC, 0.620; P<.001). Conclusions: Bladder neck D2cc >50% was the strongest predictor for grade ≥2 AUT and LUT in patients treated with LDR brachytherapy. These data support inclusion of bladder neck constraints into brachytherapy planning to decrease urinary toxicity.« less
Mavroidis, Panayiotis; Katsilieri, Zaira; Kefala, Vasiliki; Milickovic, Natasa; Papanikolaou, Nikos; Karabis, Andreas; Zamboglou, Nikolaos; Baltas, Dimos
2010-09-01
One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV), then it is reasonable to investigate whether this can be avoided. This effect can be eliminated by limiting the free modulation of the dwell times. HIPO, an inverse treatment plan optimization algorithm, offers this option. In treatment plan optimization there are various methods that try to regularize the variation of dose non-uniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution they do not provide any information regarding the expected treatment outcome as described by radiobiology based indices. The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO and modulation restriction (MR) has been compared to alternative plans with HIPO and free modulation (without MR). All common dose-volume indices for the prostate and the organs at risk have been considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in these prostate cancer cases. The radiobiological models used are the Poisson and the relative seriality models. Furthermore, the complication-free tumor control probability, P + and the biologically effective uniform dose ([Formula: see text]) were used for treatment plan evaluation and comparison. Our results demonstrate that HIPO with a modulation restriction value of 0.1-0.2 delivers high quality plans which are practically equivalent to those achieved with free modulation regarding the clinically used dosimetric indices. In the comparison, many of the dosimetric and radiobiological indices showed significantly different results. The modulation restricted clinical plans demonstrated a lower total dwell time by a mean of 1.4% that was proved to be statistically significant ( p = 0.002). The HIPO with MR treatment plans produced a higher P + by 0.5%, which stemmed from a better sparing of the OARs by 1.0%. Both the dosimetric and radiobiological comparison shows that the modulation restricted optimization gives on average similar results with the optimization without modulation restriction in the examined clinical cases. Concluding, based on our results, it appears that the applied dwell time regularization technique is expected to introduce a minor improvement in the effectiveness of the optimized HDR dose distributions.
Katsilieri, Zaira; Kefala, Vasiliki; Milickovic, Natasa; Papanikolaou, Nikos; Karabis, Andreas; Zamboglou, Nikolaos; Baltas, Dimos
2010-01-01
Purpose One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV), then it is reasonable to investigate whether this can be avoided. This effect can be eliminated by limiting the free modulation of the dwell times. HIPO, an inverse treatment plan optimization algorithm, offers this option. In treatment plan optimization there are various methods that try to regularize the variation of dose non-uniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution they do not provide any information regarding the expected treatment outcome as described by radiobiology based indices. Material and methods The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO and modulation restriction (MR) has been compared to alternative plans with HIPO and free modulation (without MR). All common dose-volume indices for the prostate and the organs at risk have been considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in these prostate cancer cases. The radiobiological models used are the Poisson and the relative seriality models. Furthermore, the complication-free tumor control probability, P+ and the biologically effective uniform dose (D¯¯) were used for treatment plan evaluation and comparison. Results Our results demonstrate that HIPO with a modulation restriction value of 0.1-0.2 delivers high quality plans which are practically equivalent to those achieved with free modulation regarding the clinically used dosimetric indices. In the comparison, many of the dosimetric and radiobiological indices showed significantly different results. The modulation restricted clinical plans demonstrated a lower total dwell time by a mean of 1.4% that was proved to be statistically significant (p = 0.002). The HIPO with MR treatment plans produced a higher P+ by 0.5%, which stemmed from a better sparing of the OARs by 1.0%. Conclusions Both the dosimetric and radiobiological comparison shows that the modulation restricted optimization gives on average similar results with the optimization without modulation restriction in the examined clinical cases. Concluding, based on our results, it appears that the applied dwell time regularization technique is expected to introduce a minor improvement in the effectiveness of the optimized HDR dose distributions. PMID:27853473
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiraishi, Yutaka; Yorozu, Atsunori; Ohashi, Toshio, E-mail: ohashi@rad.med.keio.ac.jp
2011-11-01
Purpose: To determine the rectal tolerance to Grade 2 rectal bleeding after I-125 seed brachytherapy combined with external beam radiotherapy (EBRT), based on the rectal dose-volume histogram. Methods and Materials: A total of 458 consecutive patients with stages T1 to T3 prostate cancer received combined modality treatment consisting of I-125 seed implantation followed by EBRT to the prostate and seminal vesicles. The prescribed doses of brachytherapy and EBRT were 100 Gy and 45 Gy in 25 fractions, respectively. The rectal dosimetric factors were analyzed for rectal volumes receiving >100 Gy and >150 Gy (R100 and R150) during brachytherapy and formore » rectal volumes receiving >30 Gy to 40 Gy (V30-V40) during EBRT therapy in 373 patients for whom datasets were available. The patients were followed from 21 to 72 months (median, 45 months) after the I-125 seed implantation. Results: Forty-four patients (9.7%) developed Grade 2 rectal bleeding. On multivariate analysis, age (p = 0.014), R100 (p = 0.002), and V30 (p = 0.001) were identified as risk factors for Grade 2 rectal bleeding. The rectal bleeding rate increased as the R100 increased: 5.0% (2/40 patients) for 0 ml; 7.5% (20/267 patients) for >0 to 0.5 ml; 11.0% (11/100 patients) for >0.5 to 1 ml; 17.9% (5/28 patients) for >1 to 1.5 ml; and 27.3% (6/22 patients) for >1.5 ml (p = 0.014). Grade 2 rectal bleeding developed in 6.4% (12/188) of patients with a V30 {<=}35% and in 14.1% (26/185) of patients with a V30 >35% (p = 0.02). When these dose-volume parameters were considered in combination, the Grade 2 rectal bleeding rate was 4.2% (5/120 patients) for a R100 {<=}0.5 ml and a V30 {<=}35%, whereas it was 22.4% (13/58 patients) for R100 of >0.5 ml and V30 of >35%. Conclusion: The risk of rectal bleeding was found to be significantly volume-dependent in patients with prostate cancer who received combined modality treatment. Rectal dose-volume analysis is a practical method for predicting the risk of development of Grade 2 rectal bleeding.« less
Marcon, Julian; Magistro, Giuseppe; Stief, Christian G; Grimm, Tobias
2018-04-26
There is growing interest in minimally invasive (MI) treatment options for male lower urinary tract symptoms (LUTS). Among these options, the temporary implantable nitinol device (TIND; Medi-Tate, Or Akiva, Israel) is a novel instrument used to alleviate symptoms by creating incisions in the prostate via mechanical stress. To review recent data for TIND as an MI procedure to improve LUTS. Medline, PubMed, the Cochrane Database, and Embase were screened for clinical trials, randomized controlled trials, and review articles on the use of TIND in patients with male LUTS. There are currently two studies available, one being a follow-up of the first pilot study. Both 12-mo and 36-mo results suggest at least medium-term effects of TIND in terms of symptom improvement (International Prostate Symptom Score, IPSS) and maximum urinary flow (Q max ). IPSS was improved by 41% after 12mo (p<0.001) and worsened only insignificantly after 36mo compared to baseline values. Q max increased by 4.4ml/s after 12mo (p<0.001) and did not decrease significantly after 36mo. Postoperative complications were mild and included urinary tract infection and urinary retention. Preliminary data suggest that TIND is a safe and effective MI technique for patients with male LUTS. Symptom relief and increase in urinary flow after 36mo are promising. However, long-term results are needed. Various treatment options for male patients suffering from urinary voiding symptoms are emerging. TIND, a temporary implantable nitinol device, appears to be a safe option that improves symptoms without affecting sexuality. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Le satellite Encelade source d'ions N+ dans la magnétosphère de Saturne
NASA Astrophysics Data System (ADS)
Bouhram, Mehdi; Berthelier, Jean-Jacques; Illiano, Jean-Marie; Smith, Howard T.; Sittler, Edward C.; Crary, Frank J.; Young, Dave T.
2005-12-01
xml:lang="fr">RésuméLe premier passage de la sonde Cassini dans l'environnement de Saturne, au dessus de l'anneau E, a mis en évidence l'existence d'un plasma composé d'un mélange d'ions issus des produits de l'eau (H+, O+, OH+, H2O+) avec une faible composante en ions N+ (3 %). A partir d'un modèle simple du transport des ions dans la magnétosphère, nous montrons que la source de ces ions N+ coïncide avec le satellite Encelade. Un tel résultat peut s'expliquer par la présence de composés volatiles tels que l'ammoniac NH3 sur ce satellite de glace, supposé encore actif géologiquement, ou par la présence d'ions N+ d'origine externe préalablement implantés sur sa surface. Pour citer cet article : M. Bouhram et al., C. R. Physique 6 (2005).
Weiner, Asher; Cohn, Aaron D; Balasubramaniam, Mamtha; Weiner, Adam J
2010-08-01
To summarize our clinical experience with implanting Baerveldt glaucoma tube shunts through the ciliary sulcus in eyes with a posterior chamber intraocular lens and shallow anterior chambers, corneal transplants, guttata or edema. A retrospective interventional nonrandomized noncomparative case series. Main outcome measure was postoperative corneal status. Secondary outcome measures included postoperative intraocular pressure (IOP), visual acuity and complications. Thirty-six eyes of 32 patients were identified through chart review. Follow-up period was 21.8+/-16.6 months (mean+/-standard deviation, range: 4.0 to 58.5 mo). At final visit, all 23 preoperative clear native corneas and 6 of 7 corneal transplants remained clear. Thus, of the 30 preoperative clear corneas, only 1 decompensated. Preoperative IOP was 27.9+/-11.8 mm Hg (range: 12 to 59 mm Hg), reduced postoperatively to 10.1+/-3.9 mm Hg (range: 2 to 21 mm Hg, P=0.0001), a reduction of 58.2%+/-19.3% (range: 5.0% to 95.4%). Final IOP was >or=5 and
Perez-Calatayud, Jose; Richart, Jose; Guirado, Damián; Pérez-García, Jordi; Rodríguez, Silvia; Santos, Manuel
2012-01-01
Purpose SeedSelectron® v1.26b (Nucletron BV, The Netherlands) is an afterloader system used in prostate interstitial permanent brachytherapy with I-125 selectSeed seeds. It contains a diode array to assay all implanted seeds. Only one or two seeds can be extracted during the surgical procedure and assayed using a well chamber to check the manufacturer air-kerma strength (SK) and to calibrate the diode array. Therefore, it is not feasible to assay 5–10% seeds as required by the AAPM-ESTRO. In this study, we present a practical solution of the SeedSelectron® users to fulfill the AAPM- ESTRO recommendations. Material and methods The method is based on: a) the SourceCheck® well ionization chamber (PTW, Germany) provided with a PTW insert; b) n = 10 selectSeed from the same batch and class as the seeds for the implant; c) the Nucletron insert to accommodate the n = 10 seeds on the SourceCheck® and to measure their averaged SK. Results for 56 implants have been studied comparing the SK value from the manufacturer with the one obtained with the n = 10 seeds using the Nucletron insert prior to the implant and with the SK of just one seed measured with the PTW insert during the implant. Results We are faced with SK deviation for individual seeds up to 7.8%. However, in the majority of cases SK is in agreement with the manufacturer value. With the method proposed using the Nucletron insert, the large deviations of SK are reduced and for 56 implants studied no deviation outside the range of the class were found. Conclusions The new Nucletron insert and the proposed procedure allow to evaluate the SK of the n = 10 seeds prior to the implant, fulfilling the AAPM-ESTRO recommendations. It has been adopted by Nucletron to be extended to seedSelectron® users under request. PMID:23346136
TH-B-204-01: Real-Time Tracking with Implanted Markers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Q.
Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less
TH-B-204-03: TG-199: Implanted Markers for Radiation Treatment Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Z.
Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less
TH-B-204-02: Application of Implanted Markers in Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S.
Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less
TH-B-204-00: Implanted Markers for Radiation Therapy and TG 199 Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cormack, R; Ngwa, W; Makrigiorgos, G
Purpose: Permanent prostate brachytherapy spacers can be used to deliver sustained doses of radiosentitizing drug directly to the target, in order to enhance the radiation effect. Implantable nanoplatforms for chemo-radiation therapy (INCeRTs) have a maximum drug capacity and can be engineered to control the drug release schedule. The optimal schedule for sensitization during continuous low dose rate irradiation is unknown. This work studies the optimal release schedule of drug for both traditional sensitizers, and those that work by suppressing DNA repair processes. Methods: Six brachytherapy treatment plans were used to model the anatomy, implant geometry and calculate the spatial distributionmore » of radiation dose and drug concentrations for a range of drug diffusion parameters. Three state partial differential equations (cells healthy, damaged or dead) modeled the effect of continuous radiation (radiosensitivities α,β) and cellular repair (time tr) on a cell population. Radiosensitization was modeled as concentration dependent change in α,β or tr which with variable duration under the constraint of fixed total drug release. Average cell kill was used to measure effectiveness. Sensitization by means of both enhanced damage and reduced repair were studied. Results: Optimal release duration is dependent on the concentration of radiosensitizer compared to the saturation concentration (csat) above which additional sensitization does not occur. Long duration drug release when enhancing α or β maximizes cell death when drug concentrations are generally over csat. Short term release is optimal for concentrations below saturation. Sensitization by suppressing repair has a similar though less distinct trend that is more affected by the radiation dose distribution. Conclusion: Models of sustained local radiosensitization show potential to increase the effectiveness of radiation in permanent prostate brachytherapy. INCeRTs with high drug capacity produce the greatest benefit with drug release over weeks. If in-vivo drug concentrations are not able to approach saturation concentration, durations of days is optimal. DOD 1R21CA16977501; A. David Mazzone Awards Program 2012PD164.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bloch, B. Nicolas; Department of Radiology, General Hospital Vienna, Medical University Vienna, Vienna; Lenkinski, Robert E.
2007-09-01
Purpose: To compare contrast-enhanced, T1-weighted, three-dimensional magnetic resonance imaging (CEMR) and T2-weighted magnetic resonance imaging (T2MR) with computed tomography (CT) for prostate brachytherapy seed location for dosimetric calculations. Methods and Materials: Postbrachytherapy prostate MRI was performed on a 1.5 Tesla unit with combined surface and endorectal coils in 13 patients. Both CEMR and T2MR used a section thickness of 3 mm. Spiral CT used a section thickness of 5 mm with a pitch factor of 1.5. All images were obtained in the transverse plane. Two readers using CT and MR imaging assessed brachytherapy seed distribution independently. The dependency of datamore » read by both readers for a specific subject was assessed with a linear mixed effects model. Results: The mean percentage ({+-} standard deviation) values of the readers for seed detection and location are presented. Of 1205 implanted seeds, CEMR, T2MR, and CT detected 91.5% {+-} 4.8%, 78.5% {+-} 8.5%, and 96.1% {+-} 2.3%, respectively, with 11.8% {+-} 4.5%, 8.5% {+-} 3.5%, 1.9% {+-} 1.0% extracapsular, respectively. Assignment to periprostatic structures was not possible with CT. Periprostatic seed assignments for CEMR and T2MR, respectively, were as follows: neurovascular bundle, 3.5% {+-} 1.6% and 2.1% {+-} 0.9%; seminal vesicles, 0.9% {+-} 1.8% and 0.3% {+-} 0.7%; periurethral, 7.1% {+-} 3.3% and 5.8% {+-} 2.9%; penile bulb, 0.6% {+-} 0.8% and 0.3% {+-} 0.6%; Denonvillier's Fascia/rectal wall, 0.5% {+-} 0.6% and 0%; and urinary bladder, 0.1% {+-} 0.3% and 0%. Data dependency analysis showed statistical significance for the type of imaging but not for reader identification. Conclusion: Both enumeration and localization of implanted seeds are readily accomplished with CEMR. Calculations with MRI dosimetry do not require CT data. Dose determinations to specific extracapsular sites can be obtained with MRI but not with CT.« less
Favazza, Christopher P; Edmonson, Heidi A; Ma, Chi; Shu, Yunhong; Felmlee, Joel P; Watson, Robert E; Gorny, Krzysztof R
2017-11-01
To assess risks of RF-heating of a vagus nerve stimulator (VNS) during 1.5 T prostate MRI using body coil transmit and to compare these risks with those associated with MRI head exams using a transmit/receive head coil. Spatial distributions of radio-frequency (RF) B1 fields generated by transmit/receive (T/R) body and head coils were empirically assessed along the long axis of a 1.5 T MRI scanner bore. Measurements were obtained along the center axis of the scanner and laterally offset by 15 cm (body coil) and 7 cm (head coil). RF-field measurements were supplemented with direct measurements of RF-heating of 15 cm long copper wires affixed to and submerged in the "neck" region of the gelled saline-filled (sodium chloride and polyacrylic acid) "head-and-torso" phantom. Temperature elevations at the lead tips were measured using fiber-optic thermometers with the phantom positioned at systematically increased distances from the scanner isocenter. B1 field measurements demonstrated greater than 10 dB reduction in RF power at distances beyond 28 cm and 24 cm from isocenter for body and head coil, respectively. Moreover, RF power from body coil transmit at distances greater than 32 cm from isocenter was found to be lower than from the RF power from head coil transmit measured at locations adjacent to the coil array at its opening. Correspondingly, maximum temperature elevations at the tips of the copper wires decreased with increasing distance from isocenter - from 7.4°C at 0 cm to no appreciable heating at locations beyond 40 cm. For the particular scanner model evaluated in this study, positioning an implanted VNS farther than 32 cm from isocenter (configuration achievable for prostate exams) can reduce risks of RF-heating resulting from the body coil transmit to those associated with using a T/R head coil. © 2017 American Association of Physicists in Medicine.
Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taira, Al V.; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org; Galbreath, Robert W.
Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an associationmore » between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase {>=}25%, 23% of men experienced a decrease {>=}25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response does not seem related to temporal testosterone changes.« less
Li, Chenrui; Wang, Zhijun; Wang, Qian; Ka Yan Ho, Rebecca Lucinda; Huang, Ying; Chow, Moses S.S.; Kei Lam, Christopher Wai; Zuo, Zhong
2018-01-01
Docetaxel (DTX) is widely used for metastatic castrated resistant prostate cancer, but its efficacy is often compromised by drug resistance associated with low intracellular concentrations. Piperine (PIP) could enhance the bioavailability of other drugs via the inhibition of CYPs and P-gp activities. Thus, we hypothesize a positive effect with the DTX-PIP combination on the anti-tumor efficacy and intra-tumor DTX concentrations in taxane-resistant prostate cancer. ICR-NOD/SCID mice implanted with taxane-resistant human prostate cancer cells were administrated with saline as well as PIP and DTX separately or in combination. The tumor growth was monitored together with intra-tumor concentrations of DTX. The inhibitory effects on CYPs and P-gp were further assessed in mouse liver microsome and MDCK-MDR1 cells. Compared with DTX alone, DTX-PIP combination significantly inhibited the tumor growth (114% vs. 217%, p = 0.002) with corresponding significantly higher intra-tumor DTX concentrations (5.854 ± 5.510 ng/ml vs. 1.312 ± 0.754 ng/mg, p = 0.037). The percentage of DTX metabolism was significantly decreased from 28.94 ± 1.06% to 18.14 ± 2.22% in mouse liver microsome after administration of PIP for two weeks. DTX accumulation in MDCK-MDR1 cell was significantly enhanced in the presence of PIP. Further microarray analysis revealed that PIP inhibited P-gp as well as CYP1B1 gene expression and induced a significant gene expression change relating to inflammatory response, angiogenesis, cell proliferation, or cell migration. In conclusion, DTX-PIP combination significantly induces activity against taxane-resistant prostate tumor. Such effect appeared to be attributed to the inhibitory effect of PIP on CYPs and P-gp activity as well as gene expression changes relating to tumorigenesis and cellular responses. PMID:29423050
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, I-Chow, E-mail: ihsu@radonc.ucsf.ed; Bae, Kyounghwa; Shinohara, Katsuto
2010-11-01
Purpose: To estimate the rate of late Grade 3 or greater genitourinary (GU) and gastrointestinal (GI) adverse events (AEs) after treatment with external beam radiotherapy and prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Each participating institution submitted computed tomography-based HDR brachytherapy dosimetry data electronically for credentialing and for each study patient. Patients with locally confined Stage T1c-T3b prostate cancer were eligible for the present study. All patients were treated with 45 Gy in 25 fractions using external beam radiotherapy and one HDR implant delivering 19 Gy in two fractions. All AEs were graded according to the Common Terminology Criteria formore » Adverse Events, version 3.0. Late GU/GI AEs were defined as those occurring >9 months from the start of the protocol treatment, in patients with {>=}18 months of potential follow-up. Results: A total of 129 patients from 14 institutions were enrolled in the present study. Of the 129 patients, 125 were eligible, and AE data were available for 112 patients at analysis. The pretreatment characteristics of the patients were as follows: Stage T1c-T2c, 91%; Stage T3a-T3b, 9%; prostate-specific antigen level {<=}10 ng/mL, 70%; prostate-specific antigen level >10 but {<=}20 ng/mL, 30%; and Gleason score 2-6, 10%; Gleason score 7, 72%; and Gleason score 8-10, 18%. At a median follow-up of 29.6 months, three acute and four late Grade 3 GU/GI AEs were reported. The estimated rate of late Grade 3-5 GU and GI AEs at 18 months was 2.56%. Conclusion: This is the first prospective, multi-institutional trial of computed tomography-based HDR brachytherapy and external beam radiotherapy. The technique and doses used in the present study resulted in acceptable levels of AEs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lo, Andrea C.; Morris, W. James, E-mail: JMorris@bccancer.bc.ca; Pickles, Tom
Objectives: This study examined patterns of recurrence after low–dose-rate prostate brachytherapy (LDR-PB), estimated local recurrence rate and compared that rate to the estimated local recurrence rate after radical prostatectomy (RP). Methods and Materials: A prospective database was maintained with clinical, dosimetric, and outcome data for all LDR-PB implantation procedures performed at our institution. From 1998 to 2008, 2223 patients with prostate cancer received LDR-PB without supplemental external beam radiation therapy. Patients who developed Phoenix-defined biochemical failure were reviewed for sites of relapse and investigations completed. Results: At a median follow-up of 5 years, 108 of 2223 patients (4.8%) developed biochemical relapse.more » In 1 additional patient, local relapse was found on transurethral prostate resection, but his prostate-specific antigen concentration was well short of triggering Phoenix-defined failure. Of the 109 patients with disease relapse, 18 of 2223 (0.8%) had a proven local recurrence, and 30 of 2223 (1.3%) had a proven distant recurrence. The remaining 61 of 2223 patients (2.7%) had unidentified sites of recurrence; of these, 57 patients (93%) had digital rectal examinations (DREs), 18 (30%) had post-treatment biopsies, 45 (74%) had bone scans, and 34 (56%) had computed tomography imaging of the abdomen and pelvis. If every biochemical failure were local, the local recurrence rate would be as high as 4.9%; however, by excluding those with proven distant failure and those with both a negative DRE and biopsy, we estimate that the local recurrence rate is 2.7% or less. Conclusions: In the context of limitations of the study design, our population-based analysis indicates that the local recurrence rate after LDR-PB is as low or lower than that after RP in our jurisdiction.« less
Laing, Robert; Uribe, Jennifer; Uribe-Lewis, Santiago; Money-Kyrle, Julian; Perna, Carla; Chintzoglou, Stylianos; Khaksar, Sara; Langley, Stephen E M
2018-04-01
To report clinical outcomes of 125 I low-dose-rate prostate brachytherapy (LDR-PB) as monotherapy or combined with androgen-deprivation therapy (ADT) and/or external beam radiotherapy (EBRT) in high-risk localised prostate cancer. Analysis of clinical outcomes from a prospective cohort of patients treated with LDR-PB alone or combined treatment in a single institution. Men with a high risk of disease relapse were identified by the National Institute for Health and Care Excellence (NICE) criteria or by the National Comprehensive Cancer Network (NCCN) criteria. Relapse-free survival (RFS), overall survival (OS), prostate cancer-specific survival (PCSS), and metastases-free survival (MFS), were analysed together with patient-reported symptom scores and physician-reported adverse events. The NICE and NCCN criteria identified 267 and 202 high-risk patients, respectively. NICE-defined patients had significantly lower pre-treatment PSA levels, Gleason scores <7, and a greater proportion of patients who received LDR-PB monotherapy. At 9 years after implantation RFS was 89% and 87% in the NICE and NCCN groups, respectively (log-rank P = 0.637), and OS 93% and 94%, respectively (log-rank P = 0.481). All of the survival estimates were similar between LDR-PB monotherapy and combined therapies. Cox proportional hazards regression confirmed RFS was similar between the treatment types. Treatment-related toxicity was also similar between the treatment methods. LDR-PB is effective at controlling localised prostate cancer in patients with a high risk of disease relapse. As the present study was not randomised, it is not possible to define those patients who need the addition of ADT and/or EBRT. However, the NICE criteria appear suitable to define treatment options where patients could benefit from LDR-PB as monotherapy or combined treatment. This choice should be discussed with the patient taking into account comorbidities and presence of multiple high-risk factors. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
WE-G-BRE-08: Radiosensitization by Olaparib Eluting Nanospheres
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tangutoori, S; Kumar, R; Sridhar, S
2014-06-15
Purpose: Permanent prostate brachytherapy often uses inert bio-absorbable spacers to achieve the desired geometric distribution of sources within the prostate. Transforming these spacers into implantable nanoplatforms for chemo-radiation therapy (INCeRT) provides a means of providing sustained in-situ release of radiosensitizers in the prostate to enhance the therapeutic ratio of the procedure. Olaparib, a PARP inhibitor, suppresses DNA repair processes present during low dose rate continuous irradiation. This work investigates the radiosensitizing/DNA damage repair inhibition by NanoOlaparib eluting nanospheres. Methods: Human cell line PC3 (from ATCC), was maintained in F12-k medium supplemented with fetal bovine serum. Clonogenic assay kit (from Fischermore » Scientific) was used to fix and stain the cells to determine the long term effects of irradiation. Nanoparticle size and zeta potential of nanospheres were determined using a Zeta particle size analyzer. The incorporation of Olaparib in nanospheres was evaluated by HPLC. Irradiation was performed in a small animal irradiator operating at 220 KeV.The long term effects of radio-sensitization with olaparib and nanoolaparib was determined using the clonogenic assay at 2 Gy and 4 Gy doses. The cells were allowed to grow for around 10 doubling cycles, The colonies were fixed and stained using clonogenic assay kit. The excess stain was washed off using DI water and the images were taken using a digital camera. Results: Radiosensitization studies were carried out in prostate cancer cell line, PC3 radiation at 0, 2 and 4Gy doses. Strongest dose response was observed with nanoolaparib treated cells compared to untreated cells. Conclusion: A two stage drug release of drug eluting nanospheres from a biodegradable spacer has been suggested for sustained in-situ release of Olaparib to suppress DNA repair processes during prostate brachytherapy. The Olaparib eluting nanospheres had the same in-vitro radiosensitizing effect as free olaparib. DOD 1R21CA16977501, A. David Mazzone Awards Program 2012PD164.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGrath, Deirdre M., E-mail: d.mcgrath@sheffield.ac.uk; Lee, Jenny; Foltz, Warren D.
Purpose: Validation of MRI-guided tumor boundary delineation for targeted prostate cancer therapy is achieved via correlation with gold-standard histopathology of radical prostatectomy specimens. Challenges to accurate correlation include matching the pathology sectioning plane with the in vivo imaging slice plane and correction for the deformation that occurs between in vivo imaging and histology. A methodology is presented for matching of the histological sectioning angle and position to the in vivo imaging slices. Methods: Patients (n = 4) with biochemical failure following external beam radiotherapy underwent diagnostic MRI to confirm localized recurrence of prostate cancer, followed by salvage radical prostatectomy. High-resolutionmore » 3-D MRI of the ex vivo specimens was acquired to determine the pathology sectioning angle that best matched the in vivo imaging slice plane, using matching anatomical features and implanted fiducials. A novel sectioning device was developed to guide sectioning at the correct angle, and to assist the insertion of reference dye marks to aid in histopathology reconstruction. Results: The percentage difference in the positioning of the urethra in the ex vivo pathology sections compared to the positioning in in vivo images was reduced from 34% to 7% through slicing at the best match angle. Reference dye marks were generated, which were visible in ex vivo imaging, in the tissue sections before and after processing, and in histology sections. Conclusions: The method achieved an almost fivefold reduction in the slice-matching error and is readily implementable in combination with standard MRI technology. The technique will be employed to generate datasets for correlation of whole-specimen prostate histopathology with in vivo diagnostic MRI using 3-D deformable registration, allowing assessment of the sensitivity and specificity of MRI parameters for prostate cancer. Although developed specifically for prostate, the method is readily adaptable to other types of whole tissue specimen, such as mastectomy or liver resection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buron, Catherine; Le Vu, Beatrice; Cosset, Jean-Marc
2007-03-01
Purpose: To prospectively compare health-related quality of life (HRQOL), patient-reported treatment-related symptoms, and costs of iodine-125 permanent implant interstitial brachytherapy (IB) with those of radical prostatectomy (RP) during the first 2 years after these treatments for localized prostate cancer. Methods and Materials: A total of 435 men with localized low-risk prostate cancer, from 11 French hospitals, treated with IB (308) or RP (127), were offered to complete the European Organization for Research and Treatment of Cancer core Quality of Life Questionnaire QLQ-C30 version 3 (EORTC QLQ-C30) and the prostate cancer specific EORTC QLQ-PR25 module before and at the end ofmore » treatment, 2, 6, 12, 18, and 24 months after treatment. Repeated measures analysis of variance and analysis of covariance were conducted on HRQOL changes. Comparative cost analysis covered initial treatment, hospital follow-up, outpatient and production loss costs. Results: Just after treatment, the decrease of global HRQOL was less pronounced in the IB than in the RP group, with a 13.5 points difference (p < 0.0001). A difference slightly in favor of RP was observed 6 months after treatment (-7.5 points, p = 0.0164) and was maintained at 24 months (-8.2 points, p = 0.0379). Impotence and urinary incontinence were more pronounced after RP, whereas urinary frequency, urgency, and urination pain were more frequent after IB. Mean societal costs did not differ between IB ( Euro 8,019 at T24) and RP ( Euro 8,715 at T24, p = 0.0843) regardless of the period. Conclusions: This study suggests a similar cost profile in France for IB and RP but with different HRQOL and side effect profiles. Those findings may be used to tailor localized prostate cancer treatments to suit individual patients' needs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, P; Caroprese, B; McKellar, H
2014-06-01
Purpose: To illustrate 25% reduction in CyberKnife prostate SBRT treatment times using a water filled rectal balloon. Methods: We perform prostate SBRT using a 3800cGy in 4 fraction regimen prescribed between 51% 59% iso-dose lines to 95% of PTV using a CyberKnife System. The resultant heterogeneous dosimetry is analogous to HDR dosimetry. Our patients are treated in a feet first supine position to decrease treatment couch sag and also to position the prostate anatomy closer to the robot. CT imaging is performed with a Radiadyne Immobiloc rectal balloon filled with 45-50cc water placed firmly inside the patient's rectum. A treatmentmore » plan is developed from this CT study using Multiplan. The patient is treated every other day for 4 days using the rectal balloon for each fraction. Gold fiducials previously implanted inside the prostate are used for tracking by the CyberKnife system. Results: Critical structures comprise the usual GU anatomy of bladder, rectum, urethra, femoral-heads along with emphasis on doses to anterior rectal wall and rectal mucosa. The water filled rectal balloon localizes the rectum, which enables the physician to accurately contour both anterior rectal wall, and rectal mucosa. The balloon also has a gas release valve enabling better patient comfort. Rectum localization enables the CyberKnife system to make fewer corrections resulting in fewer treatment interruptions and time lost to re-adjustment for rectal motion, bowel filling and gas creation. Effective treatment times are reduced by 25% to approximately 45 minutes. Adoption of the balloon has required minimal change to our planning strategy and plan evaluation process. Conclusion: Patient follow-up comparisons show no difference in effectiveness of treatment with and without balloons We conclude that rectal balloons enhance patient comfort and decrease effective treatment times.« less
Radiation therapy induces circulating serum Hsp72 in patients with prostate cancer.
Hurwitz, Mark D; Kaur, Punit; Nagaraja, Ganachari M; Bausero, Maria A; Manola, Judith; Asea, Alexzander
2010-06-01
Hsp72 found in the extracellular milieu has been shown to play an important role in immune regulation. The impact of common cancer therapies on extracellular release of Hsp72 however, has been to date undefined. Serum from 13 patients undergoing radiation therapy (XRT) for prostate cancer with or without hormonal therapy (ADT) was measured for levels of circulating serum Hsp72 and pro-inflammatory cytokines (IL-6 and TNF-alpha) using the classical sandwich ELISA technique and the relative expression of CD8(+) T lymphocytes and natural killer (NK) cells was measured using flow cytometry. Mouse orthotopic xenograft of human prostate cancer tumors (DU-145 and PC-3) were used to validate and further characterize the response noted in the clinical setting. The biological significance of tumor released Hsp72 was studied in human dendritic cells (DC) in vitro. Circulating serum Hsp72 levels increased an average of 3.5-fold (median per patient 4.8-fold) with XRT but not with ADT (p=0.0002). Increases in IL-6 (3.3-fold), TNF-alpha (1.8-fold), CD8(+) CTL (2.1-fold) and NK cells (3.2-fold) also occurred. Using PC-3 and DU-145 human prostate cancer xenograft models in mice, we confirmed that XRT induces Hsp72 release primarily from implanted tumors. In vitro studies using supernatant recovered from irradiated human prostate cancer cells point to exosomes containing Hsp72 as a possible stimulator of pro-inflammatory cytokine production and costimulatory molecules expression in human DC. The current study confirms for the first time in an actual clinical setting elevation of circulating serum Hsp72 with XRT. The accompanying studies in mice and in vitro identify the released exosomes containing Hsp72 as playing a pivotal role in stimulating pro-inflammatory immune responses. These findings, if validated, may lead to new treatment paradigms for common human malignancies. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Radiation therapy induces circulating serum Hsp72 in patients with prostate cancer
Hurwitz, Mark D.; Kaur, Punit; Nagaraja, Ganachari M.; Bausero, Maria A.; Manola, Judith; Asea, Alexzander
2010-01-01
Background and purpose Hsp72 found in the extracellular milieu has been shown to play an important role in immune regulation. The impact of common cancer therapies on extracellular release of Hsp72 however, has been to date undefined. Materials and methods Serum from 13 patients undergoing radiation therapy (XRT) for prostate cancer with or without hormonal therapy (ADT) was measured for levels of circulating serum Hsp72 and pro-inflammatory cytokines (IL-6 and TNF-α) using the classical sandwich ELISA technique and the relative expression of CD8+ T lymphocytes and natural killer (NK) cells was measured using flow cytometry. Mouse orthotopic xenograft of human prostate cancer tumors (DU145 and PC3) were used to validate and further characterize the response noted in the clinical setting. The biological significance of tumor released Hsp72 was studied in human dendritic cells (DC) in vitro. Results Circulating serum Hsp72 levels increased an average of 3.5-fold (median per patient 4.8-fold) with XRT but not with ADT (p = 0.0002). Increases in IL-6 (3.3-fold), TNF-α (1.8-fold), CD8+ CTL (2.1-fold) and NK cells (3.2-fold) also occurred. Using PC3 and DU145 human prostate cancer xenograft models in mice, we confirmed that XRT induces Hsp72 release primarily from implanted tumors. In vitro studies using supernatant recovered from irradiated human prostate cancer cells point to exosomes containing Hsp72 as a possible stimulator of pro-inflammatory cytokine production and costimulatory molecules expression in human DC. Conclusions The current study confirms for the first time in an actual clinical setting elevation of circulating serum Hsp72 with XRT. The accompanying studies in mice and in vitro identify the released exosomes containing Hsp72 as playing a pivotal role in stimulating pro-inflammatory immune responses. These findings, if validated, may lead to new treatment paradigms for common human malignancies. PMID:20430459
Lam, Dennis S C; Leung, Hiu Ying; Liu, Shu; Radke, Nishant; Yuan, Ye; Lee, Vincent Y W
2017-01-01
To study the safety and efficacy of 2-port pars plana anterior and central core vitrectomy (Lam floaterectomy) in combination with phacoemulsification (phaco) and intraocular lens implantation (IOL) for patients with cataract and significant floaters under topical anesthesia. Retrospective review of the first 50 consecutive cases. A standardized treatment protocol was used for patients with cataract and significant (moderate to severe) floaters (duration > 3 months). Data analysis included intraoperative and postoperative complications, floater status, and patient satisfaction. There were 50 eyes (38 patients) with a male-to-female ratio of 1 to 2.3. Twelve patients had bilateral eye surgeries. Mean age was 58.10 ± 9.85 years (range, 39-83). All patients completed the 3-month follow-up. One eye had mild vitreous hemorrhage at the end of surgery arising from sclerotomy wound oozing. No other intraoperative compli-cations were encountered. Postoperatively, there was 1 case of transient hypotony and 1 case of congestion at sclerotomy wound. No cases of retinal break or detachment, or clinically significant macular edema, were reported. There were 5 cases (10%) of mild residual floaters and 1 case (2%) of floater recurrence. Total floater clearance rate was 88%. Patient satisfaction rates were 80%, 14%, 6%, and 0% for very satisfied, satis-fied, acceptable, and unsatisfied, respectively. The 3-month results in terms of safety and efficacy of the Lam floaterectomy in combination with phaco and IOLfor patients with cataract and significant floaters under topical anesthesia are encouraging. Further larger-scale, prospective, multicenter studies seem warranted. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.
Fowler, Floyd J; McNaughton Collins, Mary; Walker Corkery, Elizabeth; Elliott, Diana B; Barry, Michael J
2002-07-15
Androgen deprivation is commonly prescribed for men with a rising prostate specific antigen level after radical prostatectomy, despite scant evidence regarding its efficacy and side effects. In the current study, the authors compared measures of health-related quality of life (HRQOL) in men who were treated with androgen deprivation after radical prostatectomy with those for men who underwent surgery but were not treated with androgen deprivation. Medicare Provider and Analysis and Review (MedPAR) files were used to identify men who had undergone radical prostatectomies between 1991-1992. Medicare Part B data then were used to select two samples: men who subsequently were androgen deprived and those who were not. In 1999, a mail survey was administered that addressed a range of disease-related and treatment-related issues, including HRQOL. Age-adjusted comparisons of responses to seven multiitem measures of HRQOL were performed. The overall response rate was 82%. On all seven HRQOL measures (impact of cancer and treatment, concern regarding body image, mental health, general health, activity, worries about cancer and dying, and energy), there were statistically significant decrements associated with androgen deprivation. Patients and physicians must weigh the price patients pay with regard to HRQOL against the uncertain benefits of early androgen deprivation. Copyright 2002 American Cancer Society.DOI 10.1002/cncr.10656
NASA Astrophysics Data System (ADS)
Goyette, Stephane
1995-11-01
Le sujet de cette these concerne la modelisation numerique du climat regional. L'objectif principal de l'exercice est de developper un modele climatique regional ayant les capacites de simuler des phenomenes de meso-echelle spatiale. Notre domaine d'etude se situe sur la Cote Ouest nord americaine. Ce dernier a retenu notre attention a cause de la complexite du relief et de son controle sur le climat. Les raisons qui motivent cette etude sont multiples: d'une part, nous ne pouvons pas augmenter, en pratique, la faible resolution spatiale des modeles de la circulation generale de l'atmosphere (MCG) sans augmenter a outrance les couts d'integration et, d'autre part, la gestion de l'environnement exige de plus en plus de donnees climatiques regionales determinees avec une meilleure resolution spatiale. Jusqu'alors, les MCG constituaient les modeles les plus estimes pour leurs aptitudes a simuler le climat ainsi que les changements climatiques mondiaux. Toutefois, les phenomenes climatiques de fine echelle echappent encore aux MCG a cause de leur faible resolution spatiale. De plus, les repercussions socio-economiques des modifications possibles des climats sont etroitement liees a des phenomenes imperceptibles par les MCG actuels. Afin de circonvenir certains problemes inherents a la resolution, une approche pratique vise a prendre un domaine spatial limite d'un MCG et a y imbriquer un autre modele numerique possedant, lui, un maillage de haute resolution spatiale. Ce processus d'imbrication implique alors une nouvelle simulation numerique. Cette "retro-simulation" est guidee dans le domaine restreint a partir de pieces d'informations fournies par le MCG et forcee par des mecanismes pris en charge uniquement par le modele imbrique. Ainsi, afin de raffiner la precision spatiale des previsions climatiques de grande echelle, nous developpons ici un modele numerique appele FIZR, permettant d'obtenir de l'information climatique regionale valide a la fine echelle spatiale. Cette nouvelle gamme de modeles-interpolateurs imbriques qualifies d'"intelligents" fait partie de la famille des modeles dits "pilotes". L'hypothese directrice de notre etude est fondee sur la supposition que le climat de fine echelle est souvent gouverne par des forcages provenant de la surface plutot que par des transports atmospheriques de grande echelle spatiale. La technique que nous proposons vise donc a guider FIZR par la Dynamique echantillonnee d'un MCG et de la forcer par la Physique du MCG ainsi que par un forcage orographique de meso-echelle, en chacun des noeuds de la grille fine de calculs. Afin de valider la robustesse et la justesse de notre modele climatique regional, nous avons choisi la region de la Cote Ouest du continent nord americain. Elle est notamment caracterisee par une distribution geographique des precipitations et des temperatures fortement influencee par le relief sous-jacent. Les resultats d'une simulation d'un mois de janvier avec FIZR demontrent que nous pouvons simuler des champs de precipitations et de temperatures au niveau de l'abri beaucoup plus pres des observations climatiques comparativement a ceux simules a partir d'un MCG. Ces performances sont manifestement attribuees au forcage orographique de meso-echelle de meme qu'aux caracteristiques de surface determinees a fine echelle. Un modele similaire a FIZR peut, en principe, etre implante sur l'importe quel MCG, donc, tout organisme de recherche implique en modelisation numerique mondiale de grande echelle pourra se doter d'un el outil de regionalisation.
Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes
İmamoğlu, Serhat
2018-01-01
Purpose To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. Results The mean follow-up duration was 11.7 ± 5.5 (range, 6–23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg (p=0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 (p=0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Conclusions Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation. PMID:29862068
Gilger, B C; Wilkie, D A; Davidson, M G; Allen, J B
2001-12-01
To evaluate the use of an intravitreal sustained-release cyclosporine (CsA) delivery device for treatment of horses with naturally occurring recurrent uveitis. 16 horses with recurrent uveitis. Horses with frequent recurrent episodes of uveitis or with disease that was progressing despite appropriate medication were selected for this study. Additional inclusion criteria included adequate retinal function as determined by use of electroretinography, lack of severe cataract formation, and no vision-threatening ocular complications (eg, retinal detachment, severe retinal degeneration, and posterior synechia). Sustained-release CsA delivery devices (4 microg of CsA/d) were implanted into the vitreous through a sclerotomy at the pars plana. Reexaminations were performed 1, 3, 6, and 12 months after implantation, then continued annually. Ophthalmic changes, number of recurrent episodes of uveitis, and vision were recorded. The rate of recurrent episodes after device implantation (0.36 episodes/y) was less than prior to surgery (75 episodes/y). In addition, only 3 horses developed episodes of recurrent uveitis after surgery. Vision was detected in 14 of 16 affected eyes at a mean follow-up time of 13.8 months (range, 6 to 24 months). This intravitreal sustained-release CsA delivery device may be a safe and important tool for long-term treatment of horses with chronic recurrent uveitis.
Alves, G G; Kinoshita, A; Oliveira, H F de; Guimarães, F S; Amaral, L L; Baffa, O
2015-07-01
Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.
The dosimetry of brachytherapy-induced erectile dysfunction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merrick, Gregory S.; Butler, Wayne M
2003-12-31
There is emerging evidence that brachytherapy-induced erectile dysfunction (ED) is technique-related and may be minimized by careful attention to source placement. Herein, we review the relationship between radiation doses to the prostate gland/surrounding structures and the development of brachytherapy-induced ED. The permanent prostate brachytherapy literature was reviewed using MEDLINE searches to ensure completeness. Although the site-specific structure associated with brachytherapy-induced ED remains unknown, there is an increasing body of data implicating the proximal penis. With day 0 CT-based dosimetry, the dose to 50% (D{sub 50}) and 25% (D{sub 25}) of the bulb of the penis should be maintained below 40%more » and 60% mPD, respectively, while the crura D{sub 50} should be maintained below 28% mPD to maximize post-brachytherapy potency. To date, there is no data to suggest that either radiation doses to the neurovascular bundles or choice of isotope is associated with brachytherapy-induced ED, while conflicting data has been reported regarding radiation dose to the prostate and the use of supplemental external beam radiation therapy. Although the etiology of brachytherapy-induced ED is likely multifactorial, the available data supports the proximal penis as an important site-specific structure. Refinements in implant technique, including preplanning and intraoperative seed placement, will result in lower radiation doses to the proximal penis with potential improvement in potency preservation.« less
Celià-Terrassa, Toni; Meca-Cortés, Óscar; Mateo, Francesca; Martínez de Paz, Alexia; Rubio, Nuria; Arnal-Estapé, Anna; Ell, Brian J.; Bermudo, Raquel; Díaz, Alba; Guerra-Rebollo, Marta; Lozano, Juan José; Estarás, Conchi; Ulloa, Catalina; ρlvarez-Simón, Daniel; Milà, Jordi; Vilella, Ramón; Paciucci, Rosanna; Martínez-Balbás, Marian; García de Herreros, Antonio; Gomis, Roger R.; Kang, Yibin; Blanco, Jerónimo; Fernández, Pedro L.; Thomson, Timothy M.
2012-01-01
Malignant progression in cancer requires populations of tumor-initiating cells (TICs) endowed with unlimited self renewal, survival under stress, and establishment of distant metastases. Additionally, the acquisition of invasive properties driven by epithelial-mesenchymal transition (EMT) is critical for the evolution of neoplastic cells into fully metastatic populations. Here, we characterize 2 human cellular models derived from prostate and bladder cancer cell lines to better understand the relationship between TIC and EMT programs in local invasiveness and distant metastasis. The model tumor subpopulations that expressed a strong epithelial gene program were enriched in highly metastatic TICs, while a second subpopulation with stable mesenchymal traits was impoverished in TICs. Constitutive overexpression of the transcription factor Snai1 in the epithelial/TIC-enriched populations engaged a mesenchymal gene program and suppressed their self renewal and metastatic phenotypes. Conversely, knockdown of EMT factors in the mesenchymal-like prostate cancer cell subpopulation caused a gain in epithelial features and properties of TICs. Both tumor cell subpopulations cooperated so that the nonmetastatic mesenchymal-like prostate cancer subpopulation enhanced the in vitro invasiveness of the metastatic epithelial subpopulation and, in vivo, promoted the escape of the latter from primary implantation sites and accelerated their metastatic colonization. Our models provide new insights into how dynamic interactions among epithelial, self-renewal, and mesenchymal gene programs determine the plasticity of epithelial TICs. PMID:22505459
Ricciardelli, Carmela; Bianco-Miotto, Tina; Jindal, Shalini; Dodd, Thomas J; Cohen, Penelope A; Marshall, Villis R; Sutherland, Peter D; Samaratunga, Hemamali; Kench, James G; Dong, Ying; Wang, Hong; Clements, Judith A; Risbridger, Gail P; Sutherland, Robert L; Tilley, Wayne D; Horsfall, David J
2010-07-01
Knowledge of preanalytic conditions that biospecimens are subjected to is critically important because novel surgical procedures, tissue sampling, handling, and storage might affect biomarker expression or invalidate tissue samples as analytes for some technologies. We investigated differences in RNA quality, gene expression by quantitative real-time PCR, and immunoreactive protein expression of selected prostate cancer biomarkers between tissues from retropubic radical prostatectomy (RRP) and robot-assisted laparoscopic prostatectomy (RALP). Sections of tissue microarray of 23 RALP and 22 RRP samples were stained with antibodies to androgen receptor (AR) and prostate-specific antigen (PSA) as intersite controls, and 14 other candidate biomarkers of research interest to three laboratories within the Australian Prostate Cancer BioResource tissue banking network. Quantitative real-time PCR was done for AR, PSA (KLK3), KLK2, KLK4, and HIF1A on RNA extracted from five RALP and five RRP frozen tissue cores. No histologic differences were observed between RALP and RRP tissue. Biomarker staining grouped these samples into those with increased (PSA, CK8/18, CKHMW, KLK4), decreased (KLK2, KLK14), or no change in expression (AR, ghrelin, Ki67, PCNA, VEGF-C, PAR2, YB1, p63, versican, and chondroitin 0-sulfate) in RALP compared with RRP tissue. No difference in RNA quality or gene expression was detected between RALP and RRP tissue. Changes in biomarker expression between RALP and RRP tissue exist at the immunoreactive protein level, but the etiology is unclear. Future studies should account for changes in biomarker expression when using RALP tissues, and mixed cohorts of RALP and RRP tissue should be avoided.
Kohan, A D; Armenakas, N A; Fracchia, J A
2000-02-01
We compare the comprehensive 1-year charges in a consecutive group of patients undergoing radical prostatectomy and transperineal interstitial brachytherapy for clinically localized prostate cancer at a single urban institution. A total of 60 consecutive men with clinically localized prostate cancer (T1-T2, N0, M0) were treated during a 15-month period with radical prostatectomy or interstitial brachytherapy. Hospital and outpatient records were analyzed for each patient in regard to preoperative, operative and postoperative charges. Parameters included number of encounters, diagnostic and therapeutic interventions, hospitalization and operative charges, and followup visits, diagnostic tests and interventions for 1 year. All charge calculations were based arbitrarily on the 1996 Medicare fee schedule, factoring in the mandated global charge reimbursement period of 90 days for both procedures. Of the patients 38 underwent radical prostatectomy (prostatectomy group) and 22 underwent interstitial brachytherapy (brachytherapy group). The brachytherapy group was older with higher pretreatment serum prostate specific antigen and clinical stage disease, and more frequently received neoadjuvant hormonal therapy compared to the prostatectomy group. The 2 groups were similar in Gleason score and, when applicable, duration of neoadjuvant hormonal therapy. Preoperative charges were 15.3% lower for prostatectomy than for brachytherapy (not statistically significant). Conversely, operative charges for prostatectomy were 13.5% higher (p = 0.04). The major difference among preoperative, operative and postoperative charges was for those incurred postoperatively by the brachytherapy group, which were 56.0% higher than those for the prostatectomy group ($2,285.20 versus $1,007.20, p = 0.0004). Transperineal interstitial seed implantation is perceived by many as more cost-effective than radical prostatectomy for patients with clinically localized prostate cancer. We demonstrated that when such patients were followed for 1 year, the comprehensive charges for radical prostatectomy and interstitial brachytherapy were equivalent.
Tselis, N; Maurer, U; Popp, W; Sack, H; Zamboglou, N
2014-04-01
The German Society of Radiation Oncology initiated a multicenter trial to evaluate core processes and subprocesses of radiotherapy by prospective evaluation of all important procedures in the most frequent malignancies treated by radiation therapy. The aim of this analysis was to assess the required resources for interstitial high-dose-rate (HDR) and low-dose-rate (LDR) prostate brachytherapy (BRT) based on actual time measurements regarding allocation of personnel and room occupation needed for specific procedures. Two radiotherapy centers (community hospital of Offenbach am Main and community hospital of Eschweiler) participated in this prospective study. Working time of the different occupational groups and room occupancies for the workflow of prostate BRT were recorded and methodically assessed during a 3-month period. For HDR and LDR BRT, a total of 560 and 92 measurements, respectively, were documented. The time needed for treatment preplanning was median 24 min for HDR (n = 112 measurements) and 6 min for LDR BRT (n = 21). Catheter implantation with intraoperative HDR real-time planning (n = 112), postimplantation HDR treatment planning (n = 112), and remotely controlled HDR afterloading irradiation (n = 112) required median 25, 39, and 50 min, respectively. For LDR real-time planning (n = 39) and LDR treatment postplanning (n = 32), the assessed median duration was 91 and 11 min, respectively. Room occupancy and overall mean medical staff times were 194 and 910 min respectively, for HDR, and 113 and 371 min, respectively, for LDR BRT. In this prospective analysis, the resource requirements for the application of HDR and LDR BRT of prostate cancer were assessed methodically and are presented for first time.
Takahashi, Noriko; Watanabe, Yusuke; Maitani, Yoshie; Yamauchi, Takayasu; Higashiyama, Kimio; Ohba, Toshihiro
2008-02-01
Fenretinide, N-(4-hydroxyphenyl)retinamide (4-HPR) is an aminophenol-containing synthetic retinoid derivative of all-trans-retinoic acid, which is a potent chemopreventive and antiproliferative agent against various cancers. Clinical studies of 4-HPR have shown side effects consisting of night blindness and ocular toxicity. To maintain potent anticancer activity without side effects, p-dodecylaminophenol (p-DDAP) was designed based on structure-activity relationships of 4-HPR. In our study, we investigate whether p-DDAP shows anticancer activity against human prostate cancer cell line PC-3 when compared with 4-HPR. p-DDAP inhibited PC-3 cell growth progressively from low to high concentration in a dose-dependent manner. p-DDAP was the most potent antiproliferative agent in vitro among 6 p-alkylaminophenols and 3 4-hydroxyphenyl analogs examined including 4-HPR. Cells treated with p-DDAP were shown to undergo apoptosis, based on condensation nuclei, cytofluorimetric analysis, propidium iodide staining and the expression of bcl-2 and caspase 3. p-DDAP arrested the S phase of the cell cycle, while 4-HPR arrested the G(0)/G(1) phase. In addition, both the i.v. and i.p. administration of p-DDAP suppressed tumor growth in PC-3-implanted mice in vivo. p-DDAP showed no effects on blood retinol concentrations, in contrast to reductions after 4-HPR administration. These results indicate that p-DDAP exhibits excellent anticancer efficacy against hormonal independent prostate cancer in vitro and in vivo, and it may have great potential for clinical use in the treatment of prostate cancer with reduced side effects. (c) 2007 Wiley-Liss, Inc.
Poder, Joel; Yuen, Johnson; Howie, Andrew; Bece, Andrej; Bucci, Joseph
2017-11-01
The purpose of this study was to assess whether deformable image registration (DIR) is required for dose accumulation of multiple high dose rate prostate brachytherapy (HDRPBT) plans treated with the same catheter pattern on two different CT datasets. DIR was applied to 20 HDRPBT patients' planning CT images who received two treatment fractions on sequential days, on two different CT datasets, with the same implant. Quality of DIR in Velocity and MIM image registration systems was assessed by calculating the Dice Similarity Coefficient (DSC) and mean distance to agreement (MDA) for the prostate, urethra and rectum contours. Accumulated doses from each system were then calculated using the same DIR technique and dose volume histogram (DVH) parameters compared to manual addition with no DIR. The average DSC was found to be 0.83 (Velocity) and 0.84 (MIM), 0.80 (Velocity) and 0.80 (MIM), 0.80 (Velocity) and 0.81 (MIM), for the prostate, rectum and urethra contours, respectively. The average difference in calculated DVH parameters between the two systems using dose accumulation was less than 1%, and there was no statistically significant difference found between deformably accumulated doses in the two systems versus manual DVH addition with no DIR. Contour propagation using DIR in velocity and MIM was shown to be at least equivalent to inter-observer contouring variability on CT. The results also indicate that dose accumulation through manual addition of DVH parameters may be sufficient for HDRPBT treatments treated with the same catheter pattern on two different CT datasets. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Keyes, Mira; Morris, William James; Spadinger, Ingrid; Araujo, Cynthia; Cheung, Arthur; Chng, Nick; Crook, Juanita; Halperin, Ross; Lapointe, Vince; Miller, Stacy; Pai, Howard; Pickles, Tom
2013-01-01
To describe in detail British Columbia (BC) Cancer Agency (BCCA) Provincial Prostate Brachytherapy (PB) Quality Assurance (QA) Program. The BCCA PB Program was established in 1997. It operates as one system, unified and supported by electronic and information systems, making it a single PB treatment provider for province of BC and Yukon. To date, >4000 patients have received PB (450 implants in 2011), making it the largest program in Canada. The Program maintains a large provincial prospective electronic database with records on all patients, including disease characteristics, risk stratification, pathology, preplan and postimplant dosimetric data, follow-up of prostate-specific antigen, and toxicity outcomes. QA was an integral part of the program since its inception. A formal QA Program was established in 2002, with key components that include: unified eligibility criteria and planning system, comprehensive database, physics and oncologist training and mentorship programs, peer review process, individual performance outcomes and feedback process, structured continuing education and routine assessment of the program's dosimetry, toxicity and prostate-specific antigen outcomes, administration and program leadership that promotes a strong culture of patient safety. The emphasis on creating a robust, broad-based network of skilled providers has been achieved by the program's requirements for training, education, and the QA process. The formal QA process is considered a key factor for the success of cancer control outcomes achieved at BCCA. Although this QA model may not be wholly transferable to all PB programs, some of its key components may be applicable to other programs to ensure quality in PB and patient safety. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.
Actinobaculum schaalii, a new cause of knee prosthetic joint infection in elderly.
Jacquier, H; Benmansour, H; Zadegan, F; Hannouche, D; Micaelo, M; Mongiat-Artus, P; Salomon, E; Cambau, E; Berçot, B
2016-08-01
Actinobaculum schaalii is an emerging pathogen particularly involved in urinary tract infection of elderly people and/or patient with urological risk factors of urinary tract infection. This microorganism is a difficult-to-diagnose pathogen and is rarely involved in systemic or deep infections. Here, we report the first case of prosthetic joint infection due to A. schaalii in an 84-year-old man with a benign prostatic hyperplasia associated with chronic retention of urine. This case underlines the importance to optimize the diagnosis of emerging uropathogens as A. schaalii, to prevent systemic infections, particularly in patients with orthopaedic implants.
Pillay, Brindha; Moon, Daniel; Love, Christopher; Meyer, Denny; Ferguson, Emma; Crowe, Helen; Howard, Nicholas; Mann, Sarah; Wootten, Addie
2017-12-01
Penile prosthesis surgery is last-line treatment to regaining erectile function after radical prostatectomy (RP) for localized prostate cancer. To assess quality of life, psychological functioning, and treatment satisfaction of men who underwent penile implantation after RP; the psychosocial correlates of treatment satisfaction and sexual function after surgery; and the relation between patients' and partners' ratings of treatment satisfaction. 98 consecutive patients who underwent penile implantation after RP from 2010 and 2015 and their partners were invited to complete a series of measures at a single time point. Of these, 71 patients and 43 partners completed measures assessing sexual function, psychological functioning, and treatment satisfaction. Proportions of patients who demonstrated good sexual function and satisfaction with treatment and clinical levels of anxiety and depression were calculated. Hierarchical regression analyses were conducted to determine psychosocial factors associated with patient treatment satisfaction and sexual function and patient-partner differences in treatment satisfaction. Patients completed the Expanded Prostate Cancer Index Composite Short Form (EPIC-26), Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS), Prostate Cancer-Related Quality of Life Scale, Self-Esteem and Relationship Questionnaire (SEAR), Generalized Anxiety Disorder-7 (GAD-7), and Patient Health Questionnaire-9 (PHQ-9). Partners completed the GAD-7, PHQ-9, EDITS (partner version), and SEAR. 94% of men reported satisfaction with treatment (EDITS score > 50). 77% of men reported good sexual function (EPIC-26 score > 60). Lower depression scores were associated with higher sexual confidence and sexual intimacy, and these were correlated with better treatment satisfaction and sexual function. Patients experienced higher sexual relationship satisfaction (median score = 90.6) than their partners (median score = 81.2), but there was no difference in treatment satisfaction between groups. Higher patient treatment satisfaction was more likely to be reported for couples whose depression scores were more similar. It is important to provide preoperative penile implant counseling and encourage patients to seek postoperative counseling if needed. This is one of the first Australian-based studies comprehensively assessing treatment satisfaction and psychosocial health of men after penile prosthesis surgery after RP. This was a retrospective cross-sectional study, so there is a possibility of recall bias, and causal associations could not be determined. Men in this Australian series who underwent penile prosthesis surgery after RP generally reported good sexual function and treatment satisfaction. Nevertheless, patient and partner mental health influenced their reported experience of the treatment. Pillay B, Moon D, Love C, et al. Quality of Life, Psychological Functioning, and Treatment Satisfaction of Men Who Have Undergone Penile Prosthesis Surgery Following Robot-Assisted Radical Prostatectomy. J Sex Med 2017;14:1612-1620. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Therriault-Proulx, F; Bruno, T; Beddar, S
Purpose: To validate in a water phantom the use of plastic scintillation detectors to measure dose to the urethra and the rectal wall during a clinically realistic low dose rate (LDR) brachytherapy implant. Methods: A template was designed to replicate a clinically realistic LDR brachytherapy prostate implant inside a water phantom. Twenty-two catheters were inserted, including one mimicking the urethra and another the rectal wall. The needles inserted in the remaining 20 catheters were composed of thin-walled nylon tubes in which I-125 radioactive seeds (Air Kerma Strengths of (0.328±0.020)U) were abutted together with plastic spacers to replicate a typical loading.more » A plastic scintillation detector (PSD) with a 5-mm long × 1-mm diameter sensitive element was first placed inside the urethra and 1-second measurements were performed for 60s after each needle implant. Measurements were also performed at multiple positions along the urethra once all the needles were inserted. The procedure was then repeated with the PSD placed at the rectal wall. Results: Individual dose-rates ranging from 0.07µGy/s to 1.5µGy/s were measured after each needle implant. The average absolute relative differences were (6.2±3.6)% and (6.9±6.5)% to the values calculated with the TG-43 formalism, for the urethra and rectal wall respectively. These results are within expectations from the error uncertainty budget once accounting for uncertainties in seeds’ strength and positioning. Interestingly, the PSD allowed for unplanned error detection as the study was performed. Finally, the measured dose after the full implant at different positions along the mimicked organs at risk were in agreement with TG-43 values for all of the positions tested. Conclusion: Plastic scintillation detectors could be used as in vivo detectors for LDR brachytherapy as they would provide accurate dose information after each needle implant as well as along the organs at risk at the end of the implant.« less
Giantsoudi, Drosoula; De Man, Bruno; Verburg, Joost; Trofimov, Alexei; Jin, Yannan; Wang, Ge; Gjesteby, Lars; Paganetti, Harald
2017-04-21
A significant and increasing number of patients receiving radiation therapy present with metal objects close to, or even within, the treatment area, resulting in artifacts in computed tomography (CT) imaging, which is the most commonly used imaging method for treatment planning in radiation therapy. In the presence of metal implants, such as dental fillings in treatment of head-and-neck tumors, spinal stabilization implants in spinal or paraspinal treatment or hip replacements in prostate cancer treatments, the extreme photon absorption by the metal object leads to prominent image artifacts. Although current CT scanners include a series of correction steps for beam hardening, scattered radiation and noisy measurements, when metal implants exist within or close to the treatment area, these corrections do not suffice. CT metal artifacts affect negatively the treatment planning of radiation therapy either by causing difficulties to delineate the target volume or by reducing the dose calculation accuracy. Various metal artifact reduction (MAR) methods have been explored in terms of improvement of organ delineation and dose calculation in radiation therapy treatment planning, depending on the type of radiation treatment and location of the metal implant and treatment site. Including a brief description of the available CT MAR methods that have been applied in radiation therapy, this article attempts to provide a comprehensive review on the dosimetric effect of the presence of CT metal artifacts in treatment planning, as reported in the literature, and the potential improvement suggested by different MAR approaches. The impact of artifacts on the treatment planning and delivery accuracy is discussed in the context of different modalities, such as photon external beam, brachytherapy and particle therapy, as well as by type and location of metal implants.
NASA Astrophysics Data System (ADS)
Giantsoudi, Drosoula; De Man, Bruno; Verburg, Joost; Trofimov, Alexei; Jin, Yannan; Wang, Ge; Gjesteby, Lars; Paganetti, Harald
2017-04-01
A significant and increasing number of patients receiving radiation therapy present with metal objects close to, or even within, the treatment area, resulting in artifacts in computed tomography (CT) imaging, which is the most commonly used imaging method for treatment planning in radiation therapy. In the presence of metal implants, such as dental fillings in treatment of head-and-neck tumors, spinal stabilization implants in spinal or paraspinal treatment or hip replacements in prostate cancer treatments, the extreme photon absorption by the metal object leads to prominent image artifacts. Although current CT scanners include a series of correction steps for beam hardening, scattered radiation and noisy measurements, when metal implants exist within or close to the treatment area, these corrections do not suffice. CT metal artifacts affect negatively the treatment planning of radiation therapy either by causing difficulties to delineate the target volume or by reducing the dose calculation accuracy. Various metal artifact reduction (MAR) methods have been explored in terms of improvement of organ delineation and dose calculation in radiation therapy treatment planning, depending on the type of radiation treatment and location of the metal implant and treatment site. Including a brief description of the available CT MAR methods that have been applied in radiation therapy, this article attempts to provide a comprehensive review on the dosimetric effect of the presence of CT metal artifacts in treatment planning, as reported in the literature, and the potential improvement suggested by different MAR approaches. The impact of artifacts on the treatment planning and delivery accuracy is discussed in the context of different modalities, such as photon external beam, brachytherapy and particle therapy, as well as by type and location of metal implants.
Friedl, Alexander; Mühlstädt, Sandra; Rom, Maximilian; Kivaranovic, Danijel; Mohammed, Nasreldin; Fornara, Paolo; Brössner, Clemens
2016-04-01
To identify risk factors for treatment failure of men with the adjustable transobturator male system (ATOMS) for treating stress urinary incontinence (SUI). Sixty-two patients with SUI after prostate surgery were provided with an ATOMS. The self-defined criteria for treatment failure (implant removal [A], no improvement or ≥3 pads/24 hours [B], and no improvement or ≥150 mL urine loss/24 hours [C]) were compared to anamnestic, clinical, and time-specific parameters: age, Charlson comorbidity index (CCI), urine culture (UC), previous ineffective implants, body mass index, radiotherapy, renal function (serum creatinine), smoker status, urethral strictures, SUI severity, surgery time, time to and season at implantation, and port system application. After a median follow-up of 17.7 months, 9 ATOMS (15%) were removed due to infection (8) or dysfunction (1); 23% and 16% had treatment failure of criteria B and C. Dry rate/overall success rate was 61%/87%. Age alone was no risk factor but the CCI and a positive UC were univariate significant predictors of the criteria A, B, and C. Besides, previous devices and renal failure were significantly associated with implant removal (A) and SUI severity with criterion C. In multivariate analysis, previous devices (P = .0163), positive UC (P = .0190), and SUI severity (P = .0123) were the strongest predictors of A, B, and C, respectively. A poor CCI, preoperative positive UC, severe SUI, and previous implants lead to more treatment failure and removal. Age, body mass index, radiotherapy, urethral strictures, current smoking, time-specific parameters, seasonality, and port system application did not influence the outcome. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Nédellec, P.; Dumoulin, L.; Burger, J. P.; Bernas, H.; Köstler, H.; Traverse, A.
1993-11-01
Metastable MgHx hydride was prepared by H ion implantation into Mg films at 5 K. The resistivity and magnetoresistance temperature dependence reveal weak localization effects due to atomic disorder. At low hydrogen concentrations, x le 0.3, the conductivity varies as σ sim log(T), typical of two-dimensional weak localization behaviour. The resistivity is also very sensitive to the sample inhomogeneity, due to H diffusion, which can be modelled by introducing a temperature-dependent geometrical percolating factor G. At higher H concentrations, 0.7 le x le 3, after annealing at 20 K, 50 K and 110 K, the samples also exhibit weak localization but with three-dimensional behaviour i.e. a σ sim sqrt{T}. Our analysis is consistent with the existence of an inhomogeneous system formed by a mixture of two phases with contrasted conduction properties, one of which is a well-behaved metal, while the other displays the localization properties. The results lead us to identify the former phase to a non percolating superconducting phase at low temperature. Des films d'hydrure MgHx sont préparés, hors de l'équilibre thermodynamique, par implantation d'ions H dans des films de Mg maintenus à 5 K. La mesure de la résistance et de la magnétorésistance en fonction de la température met en évidence des effets importants de localisation électronique due au désordre atomique. Pour les faibles concentrations d'hydrogène, x le 0,3, la conductivité varie comme σ sim log(T), variation caractéristique d'un comportement dominé par les effets de localisation électronique faible à 2 dimensions. La résistivité est très sensible aux effets d'inhomogénéité, liés à la diffusion de H. Nous avons modélisé ces effets en introduisant un coefficient géométrique variant avec la température. Pour les concentrations plus élevées (0, 7 le x le 3), après un recuit à 20 K, 50 K et 110 K, les films montrent également des effets de localisation mais la conductivité varie maintenant comme σ sim sqrt{T}, caractéristique d'un comportement tridimensionnel. L'analyse des résultats est compatible avec l'hypothèse d'un système inhomogène formé du mélange de deux phases avec des propriétés électriques contrastées : un “mauvais métal" et un “bon métal" qui, à basse température, pourrait présenter un état supraconducteur non percolant.
Poster - Thur Eve - 03: LDR to HDR: RADPOS applications in brachytherapy.
Cherpak, A J; Cygler, J E; Kertzscher, G; E, C; Perry, G
2012-07-01
The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor and either one or five MOSFET dosimeters. The feasibility of using the system for quality control has been explored for a range of radiotherapy treatment techniques including most recently transperineal interstitial permanent prostate brachytherapy and high dose rate (HDR) treatments. Dose and position information was collected by a RADPOS array detector inside a Foley catheter within patients' urethra during permanent seed implantation. Ten patients were studied, and average displacement during implantation was Δr = (1.4-5.1) mm, with movements up to 9.7 mm due to the removal of the transrectal ultrasound probe. Maximum integral dose in the prostatic urethra ranged from 110-195 Gy, and it was found that the dose can change up to 63 cGy (62.0%) depending on whether the rectal probe is in place. For HDR, a RADPOS detector was first calibrated with an Ir-192 source. A treatment was then simulated using a total of 50 dwell positions in 5 catheters in an acrylic phantom. Dwell positions ranged from 1 to 10 cm away from the RADPOS detector and dose was measured for each source position. An average calibration coefficient of 0.74±0.11 cGy/mV was calculated for the detector and the average absolute difference between measured values and expected dose was 0.7±5.4 cGy (5±20%). The demonstrated accuracy of RADPOS dose measurements along with its ability to simultaneously measure displacement makes it a powerful tool for brachytherapy treatments, where high dose gradients can present unique in vivo dosimetry challenges. © 2012 American Association of Physicists in Medicine.
Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs.
Goossen, A; Weber, G M; Dries, S P M
2012-01-01
For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative radiographs. In a two step approach we first detect and segment any implants or other artificial objects within the image. We exploit physical characteristics and avoid prior shape information to cope with the vast amount of implant types. Subsequently, we exploit the implant delineations to adapt the initialization and adaptation phase of a dedicated bone segmentation scheme using deformable template models. Implant and bone contours are fused to derive the final joint segmentation and thus the alignment measurements. We evaluated our method on clinical long leg radiographs and compared both the initialization rate, corresponding to the number of images successfully processed by the proposed algorithm, and the accuracy of the alignment measurement. Ground truth has been generated by an experienced orthopedic surgeon. For comparison a second reader reevaluated the measurements. Experiments on two sets of 70 and 120 digital radiographs show that 92% of the joints could be processed automatically and the derived measurements of the automatic method are comparable to a human reader for pre-operative as well as post-operative images with a typical error of 0.7° and correlations of r = 0.82 to r = 0.99 with the ground truth. The proposed method allows deriving objective measures of joint alignment from clinical radiographs. Its accuracy and precision are on par with a human reader for all evaluated measurements.
Ashraf, Munis; Sharma, Om Prakash; Priyavadhana, Sruthi; Sambandam, Senthil Nathan; Mounasamy, Varatharaj
2017-01-01
Over the years, proponents of total knee designs (cruciate retaining and posterior stabilised) have conducted several long-term studies to claim the potential of these designs in several subsets of patients. Total knee arthroplasty (TKA) in patients with rheumatoid arthritis has also been one such domain where numerous studies were conducted in the past. A general perception among majority of arthroplasty surgeons is that, posterior stabilised (PS) is the implanted design of choice among patients with Rheumatoid arthritis (RA). However, with the available literature there is a significant disparity related to the selection of implants in patients with rheumatoid RA. In this review of literature, an attempt is made to identify the clinical performance and role of one such implant design, the cruciate retaining (CR) prosthesis in rheumatoid arthritis. The review was conducted after a series of advanced search in the following medical databases; Pub med, Biomed central, Cochrane and Google scholar for articles related to long term follow up studies of cruciate retaining total knee arthroplasty in rheumatoid arthritis using the keywords cruciate retaining prosthesis, total knee arthroplasty, rheumatoid arthritis. The available data demonstrate that the CR design is attributed with an excellent long term survivorship and functional outcome even in follow up studies up to twenty-five years. The advantages of using a CR design are long term survivorship, controlled femoral roll back and preservation of bone stock. Thus, the data gathered in this review lead to a consideration that the CR design is an implant design on par with PS design in patients with RA.
Dunia, Gisèle Mawazo Binti
2013-01-01
Depuis 2005, la République Démocratique du Congo a amorcé l'implantation des sites de soins communautaires. Cette stratégie a pour objectif de rapprocher les services de santé des populations éloignées. Bien que cela parte d'une bonne intention, elle résulte, à notre sens, en une consécration d'un système de santé à deux vitesses. En effet, les populations vivant en ville ont accès à des soins prestés par des agents de santé formés alors que celles vivant en milieu rural reculé ont pour prestataires de soins des relais communautaires. Cette situation marginalise encore plus des populations dont la situation géographique est déjà préoccupante. Pourtant, la population est prête à parcourir des kilomètres en échange d'un service qu'elle estime de qualité. PMID:23785563
Lediju Bell, Muyinatu A.; Sen, H. Tutkun; Iordachita, Iulian; Kazanzides, Peter; Wong, John
2014-01-01
Abstract. Ultrasound can provide real-time image guidance of radiation therapy, but the probe-induced tissue deformations cause local deviations from the treatment plan. If placed during treatment planning, the probe causes streak artifacts in required computed tomography (CT) images. To overcome these challenges, we propose robot-assisted placement of an ultrasound probe, followed by replacement with a geometrically identical, CT-compatible model probe. In vivo reproducibility was investigated by implanting a canine prostate, liver, and pancreas with three 2.38-mm spherical markers in each organ. The real probe was placed to visualize the markers and subsequently replaced with the model probe. Each probe was automatically removed and returned to the same position or force. Under position control, the median three-dimensional reproducibility of marker positions was 0.6 to 0.7 mm, 0.3 to 0.6 mm, and 1.1 to 1.6 mm in the prostate, liver, and pancreas, respectively. Reproducibility was worse under force control. Probe substitution errors were smallest for the prostate (0.2 to 0.6 mm) and larger for the liver and pancreas (4.1 to 6.3 mm), where force control generally produced larger errors than position control. Results indicate that position control is better than force control for this application, and the robotic approach has potential, particularly for relatively constrained organs and reproducibility errors that are smaller than established treatment margins. PMID:26158038
In vivo photoacoustic imaging of prostate brachytherapy seeds
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Kuo, Nathanael P.; Song, Danny Y.; Kang, Jin; Boctor, Emad M.
2014-03-01
We conducted an approved canine study to investigate the in vivo feasibility of photoacoustic imaging for intraoperative updates to brachytherapy treatment plans. Brachytherapy seeds coated with black ink were inserted into the canine prostate using methods similar to a human procedure. A transperineal, interstitial, fiber optic light delivery method, coupled to a 1064 nm laser, was utilized to irradiate the prostate and the resulting acoustic waves were detected with a transrectal ultrasound probe. The fiber was inserted into a high dose rate (HDR) brachytherapy needle that acted as a light-diffusing sheath, enabling radial light delivery from the tip of the fiber inside the sheath. The axis of the fiber was located at a distance of 4-9 mm from the long axis of the cylindrical seeds. Ultrasound images acquired with the transrectal probe and post-operative CT images of the implanted seeds were analyzed to confirm seed locations. In vivo limitations with insufficient light delivery within the ANSI laser safety limit (100 mJ/cm2) were overcome by utilizing a short-lag spatial coherence (SLSC) beamformer, which provided average seed contrasts of 20-30 dB for energy densities ranging 8-84 mJ/cm2. The average contrast was improved by up to 20 dB with SLSC beamforming compared to conventional delay-and-sum beamforming. There was excellent agreement between photoacoustic, ultrasound, and CT images. Challenges included visualization of photoacoustic artifacts that corresponded with locations of the optical fiber and hyperechoic tissue structures.
Emerging Minimally Invasive Treatment Options for Male Lower Urinary Tract Symptoms.
Magistro, Giuseppe; Chapple, Christopher R; Elhilali, Mostafa; Gilling, Peter; McVary, Kevin T; Roehrborn, Claus G; Stief, Christian G; Woo, Henry H; Gratzke, Christian
2017-12-01
Lower urinary tract symptoms (LUTS) are one of the most common and troublesome nonmalignant conditions affecting quality of life in aging men. A spectrum of established medical and surgical options is available to provide relief of bothersome LUTS. Both the adverse events of medication and the morbidity with surgical treatment modalities have to be counterbalanced against efficacy. Novel minimally invasive treatment options aim to be effective, ideally to be performed in an ambulatory setting under local anaesthesia and to offer a more favourable safety profile than existing reference techniques. A comprehensive, narrative review of novel minimally invasive treatment modalities for the management of male LUTS due to benign prostatic enlargement is presented. Medline, PubMed, Cochrane database, and Embase were screened for randomised controlled trials (RCTs), clinical trials, and reviews on novel minimally invasive treatment options for male LUTS due to benign prostatic enlargement. With regard to newly devised intraprostatic injectables (botulinum neurotoxin A, NX1207, PRX302), PRX302 is currently the only substance that was superior to placebo in a phase 3 RCT providing proof of efficacy and safety. The prostatic urethral lift technique has been evaluated in several phase 3 trials showing rapid and durable relief of LUTS without compromising sexual function in carefully selected patients without a prominent median lobe. The first clinical experience of the temporary implantable nitinol device demonstrated that implantation of this novel device is a safe procedure, easy, and fast to perform. Further studies are required to evaluate efficacy, durability, and to define appropriate patient selection. New ablative approaches like the image guided robotic waterjet ablation (AquaBeam) or procedures based on convective water vapour energy (Rezūm) are in the early stages of development. Prostatic artery embolization performed by interventional radiologists at specialised centres shows a high technical success rate in the treatment of bothersome LUTS. However, a substantial clinical failure rate and a particular spectrum of complications not commonly seen after urologic interventions do occur and need to be critically evaluated. Initial promising clinical results on novel minimally invasive treatment options indicate efficacy comparable to standard techniques, often associated with a more favourable safety profile, in particular with preservation of sexual function. Many of these techniques are in their infancy and based on experience of new developments in the past. Further RCTs are required to evaluate efficacy, safety, and durability of novel techniques with long-term follow-up and careful evaluation of the selection criteria, which have been applied in clinical trials. The prostatic urethral lift is the only procedure with Level 1 evidence data and that can therefore be recommended for treatment of male LUTS in clinical practice for selected patients. Minimally invasive treatment options have been developed to provide relief of lower urinary tract symptoms comparable to standard surgical techniques with a more favourable safety profile. However, long-term clinical evaluation is still needed for most of these innovations before they can be recommended to be an effective replacement for standard surgical treatment. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Schwarzenböck, Sarah Marie; Schmeja, Philipp; Kurth, Jens; Souvatzoglou, Michael; Nawroth, Roman; Treiber, Uwe; Kundt, Guenther; Berndt, Sandra; Graham, Keith; Senekowitsch-Schmidtke, Reingard; Schwaiger, Markus; Ziegler, Sibylle I; Dinkelborg, Ludger; Wester, Hans-Jürgen; Krause, Bernd Joachim
2016-06-01
Carbon-11- and fluorine-18-labeled choline derivatives are commonly used in prostate cancer imaging in the clinical setting for staging and re-staging of prostate cancer. Due to a limited detection rate of established positron emission tomography (PET) tracers, there is a clinical need for innovative tumor-specific PET compounds addressing new imaging targets. The aim of this study was to compare the properties of [(18)F]Bombesin (BAY 86-4367) as an innovative biomarker for prostate cancer imaging targeting the gastrin-releasing peptide receptor and [(11)C]Choline ([(11)C]CHO) in a human prostate tumor mouse xenograft model by small animal PET/X-ray computed tomography (CT). We carried out a dual-tracer small animal PET/CT study comparing [(18)F]Bombesin and [(11)C]CHO. The androgen-independent human prostate tumor cell line PC-3 was implanted subcutaneously in the flanks of nu/nu NMRI mice (n = 10) (PET/CT measurements of two [(11)C]Choline mice could not be analyzed due to technical reasons). [(18)F]Bombesin and [(11)C]CHO PET/CT imaging was performed about 3-4 weeks after the implantation of PC-3 cells on two separate days. After the intravenous tail vein injection of 14 MBq [(18)F]Bombesin and 37 MBq [(11)C]CHO, respectively, a dynamic study over 60 min was acquired in list mode using an Inveon animal PET/CT scanner (Siemens Medical Solutions). The sequence of [(18)F]Bombesin and [(11)C]CHO was randomized. Image analysis was performed using summed images as well as dynamic data. To calculate static and dynamic tumor-to-muscle (T/M), tumor-to-blood (T/B), liver-to-blood (L/B), and kidney-to-blood (K/B) ratios, 4 × 4 × 4 mm(3) volumes of interest (VOIs) of tumor, muscle (thigh), liver, kidney, and blood derived from transversal slices were used. The mean T/M ratio of [(18)F]Bombesin and [(11)C]CHO was 6.54 ± 2.49 and 1.35 ± 0.30, respectively. The mean T/B ratio was 1.83 ± 0.79 for [(18)F]Bombesin and 0.55 ± 0.10 for [(11)C]CHO. The T/M ratio as well as the T/B ratio for [(18)F]Bombesin were significantly higher compared to those for [(11)C]CHO (p < 0.001, respectively). Kidney and liver uptake was statistically significantly lower for [(18)F]Bombesin (K/B 3.41 ± 0.81, L/B 1.99 ± 0.38) compared to [(11)C]CHO [K/B 7.91 ± 1.85 (p < 0.001), L/B 6.27 ± 1.99 (p < 0.001)]. The magnitudes of the time course of T/M and T/B ratios (T/M and T/Bdyn ratios) were statistically significantly different (showing a higher uptake of [(18)F]Bombesin compared to [(11)C]CHO); additionally, also the change of the T/M and T/B ratios over time was significantly different between both tracers in the dynamic analysis (p < 0.001, respectively). Furthermore, there was a statistically significantly different change of the K/B and L/B ratios over time between the two tracers in the dynamic analysis (p = 0.026 and p < 0.001, respectively). [(18)F]Bombesin (BAY 86-4367) visually and semi-quantitatively outperforms [(11)C]CHO in the PC-3 prostate cancer xenograft model. [(18)F]Bombesin tumor uptake was significantly higher compared to [(11)C]CHO. [(18)F]Bombesin showed better imaging properties compared to the clinically utilized [(11)C]CHO due to a higher tumor uptake as well as a lower liver and kidney uptake.
Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise
To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTV prostate+3mm . The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTV prostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
New Diagnostic and Therapeutic Approaches for Preventing the Progression of Diabetic Retinopathy
Park, Young Gun; Roh, Young-Jung
2016-01-01
Diabetic retinopathy (DR) is a severe sight-threatening complication of diabetes mellitus. Retinal laser photocoagulation, antivascular endothelial growth factors, steroid therapy, and pars plana vitrectomy are now used extensively to treat advanced stages of diabetic retinopathy. Currently, diagnostic devices like ultrawide field fundus fluorescein angiography and the improvement of optical coherence tomography have provided quicker and more precise diagnosis of early diabetic retinopathy. Thus, treatment protocols have been modified accordingly. Various types of lasers, including the subthreshold micropulse laser and RPE-targeting laser, and selective targeted photocoagulation may be future alternatives to conventional retinal photocoagulation, with fewer complications. The new developed intravitreal medications and implants have provided more therapeutic options, with promising results. PMID:26881240
Branch retinal artery occlusion post-penetrating globe injury with intraocular foreign body.
Nagpal, Manish; Chaudhary, Pranita; Jain, Ashish
2018-01-01
Intraocular foreign body (IOFB) in cases of penetrating eye injury accounts for an important indication of vitreoretinal intervention following ocular trauma. Vascular occlusion as a complication of IOFB is rare. Here we present a case of a 34-year-old male with post-traumatic cataract and an intraocular metallic foreign body (IOFB) lodged in the superficial layers of the retina inferotemporal to the disc, causing an inferotemporal branch retinal artery occlusion. The case was managed by lensectomy with pars plana vitrectomy and IOFB removal followed by a second procedure of secondary IOL implantation. Final best-corrected visual acuity improved to 6/24. This case highlights an unusual sequelae following penetrating ocular trauma.
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Sen, H. Tutkun; Iordachita, Iulian; Kazanzides, Peter; Wong, John
2014-03-01
Radiation therapy is used to treat cancer by delivering high-dose radiation to a pre-defined target volume. Ultrasound (US) has the potential to provide real-time, image-guidance of radiation therapy to identify when a target moves outside of the treatment volume (e.g. due to breathing), but the associated probe-induced tissue deformation causes local anatomical deviations from the treatment plan. If the US probe is placed to achieve similar tissue deformations in the CT images required for treatment planning, its presence causes streak artifacts that will interfere with treatment planning calculations. To overcome these challenges, we propose robot-assisted placement of a real ultrasound probe, followed by probe removal and replacement with a geometrically-identical, CT-compatible model probe. This work is the first to investigate in vivo deformation reproducibility with the proposed approach. A dog's prostate, liver, and pancreas were each implanted with three 2.38-mm spherical metallic markers, and the US probe was placed to visualize the implanted markers in each organ. The real and model probes were automatically removed and returned to the same position (i.e. position control), and CT images were acquired with each probe placement. The model probe was also removed and returned with the same normal force measured with the real US probe (i.e. force control). Marker positions in CT images were analyzed to determine reproducibility, and a corollary reproducibility study was performed on ex vivo tissue. In vivo results indicate that tissue deformations with the real probe were repeatable under position control for the prostate, liver, and pancreas, with median 3D reproducibility of 0.3 mm, 0.3 mm, and 1.6 mm, respectively, compared to 0.6 mm for the ex vivo tissue. For the prostate, the mean 3D tissue displacement errors between the real and model probes were 0.2 mm under position control and 0.6 mm under force control, which are both within acceptable radiotherapy treatment margins. The 3D displacement errors between the real and model probes were less acceptable for the liver and pancreas (4.1-6.1 mm), and force control maintained poorer reproducibility than position control.
NASA Astrophysics Data System (ADS)
Prakash, Punit; Chen, Xin; Wootton, Jeffery; Pouliot, Jean; Hsu, I.-Chow; Diederich, Chris J.
2009-02-01
A 3D optimization-based thermal treatment planning platform has been developed for the application of catheter-based ultrasound hyperthermia in conjunction with high dose rate (HDR) brachytherapy for treating advanced pelvic tumors. Optimal selection of applied power levels to each independently controlled transducer segment can be used to conform and maximize therapeutic heating and thermal dose coverage to the target region, providing significant advantages over current hyperthermia technology and improving treatment response. Critical anatomic structures, clinical target outlines, and implant/applicator geometries were acquired from sequential multi-slice 2D images obtained from HDR treatment planning and used to reconstruct patient specific 3D biothermal models. A constrained optimization algorithm was devised and integrated within a finite element thermal solver to determine a priori the optimal applied power levels and the resulting 3D temperature distributions such that therapeutic heating is maximized within the target, while placing constraints on maximum tissue temperature and thermal exposure of surrounding non-targeted tissue. This optimizationbased treatment planning and modeling system was applied on representative cases of clinical implants for HDR treatment of cervix and prostate to evaluate the utility of this planning approach. The planning provided significant improvement in achievable temperature distributions for all cases, with substantial increase in T90 and thermal dose (CEM43T90) coverage to the hyperthermia target volume while decreasing maximum treatment temperature and reducing thermal dose exposure to surrounding non-targeted tissues and thermally sensitive rectum and bladder. This optimization based treatment planning platform with catheter-based ultrasound applicators is a useful tool that has potential to significantly improve the delivery of hyperthermia in conjunction with HDR brachytherapy. The planning platform has been extended to model thermal ablation, including the addition of temperature dependent attenuation, perfusion, and tissue damage. Pilot point control at the target boundaries was implemented to control power delivery to each transducer section, simulating an approach feasible for MR guided procedures. The computer model of thermal ablation was evaluated on representative patient anatomies to demonstrate the feasibility of using catheter-based ultrasound thermal ablation for treatment of benign prostate hyperplasia (BPH) and prostate cancer, and to assist in designing applicators and treatment delivery strategies.
Ghilezan, Michel; Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye, Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy
2012-07-01
To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy × 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy × 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of ≤12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Favorable-risk prostate cancer patients treated with a single implant HDR-BT to 24-27 Gy in two fractions within 1 day have excellent tolerance with minimal acute and chronic toxicity. Longer follow-up is needed to confirm these encouraging early results. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghilezan, Michel, E-mail: mghilezan@beaumont.edu; Martinez, Alvaro; Gustason, Gary
2012-07-01
Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, onlymore » 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable-risk prostate cancer patients treated with a single implant HDR-BT to 24-27 Gy in two fractions within 1 day have excellent tolerance with minimal acute and chronic toxicity. Longer follow-up is needed to confirm these encouraging early results.« less
Étude des déterminants individuels de l’adoption du dossier de santé électronique du Québec
Mezni, H; M-P, Gagnon; Duplantie, J
2016-01-01
Résumé Objectif Selon des études précédentes, les dossiers de santé électroniques peuvent améliorer l’efficacité, la sécurité et la qualité de la prise en charge médicale. Cependant, les prestataires de soins restent réticents quant à son utilisation, ce qui limite son impact sur le système de santé. La présente étude avait pour objectif d’évaluer les perceptions des médecins face au dossier de santé du Québec. Méthodes À partir d’une revue de la littérature sur les facteurs influençant l’adoption des nouvelles technologies de l’information et des communications (NTIC) en général et de la cybersanté en particulier, nous avons élaboré un questionnaire semi-structuré. Au total, 12 médecins utilisateurs potentiels du dossier de santé du Québec (DSQ) ont complété et retourné le questionnaire. Par la suite, nous avons opéré une analyse thématique de contenu, suivie par une théorisation des concepts obtenus. Résultats L’intention d’adopter le DSQ est influencée positivement par l’utilité perçue, la facilité d’utilisation perçue, la démonstrabilité des résultats, la compatibilité du système avec la pratique et l’autoefficacité informatique perçue par les médecins. Inversement, la résistance au changement influence négativement l’adoption du DSQ par les médecins. Conclusion L’identification des déterminants de l’adoption du dossier de santé du Québec est cruciale pour les responsables du secteur de la santé au Québec. Il sera ainsi possible de saisir les attentes des utilisateurs potentiels et d’ajuster les stratégies d’implantation en vue de favoriser une meilleure intégration de cette technologie dans les pratiques médicales. PMID:27867453
Kasten, Benjamin B; Ma, Xiaowei; Cheng, Kai; Bu, Lihong; Slocumb, Winston S; Hayes, Thomas R; Trabue, Steven; Cheng, Zhen; Benny, Paul D
2016-01-20
Developing new strategies to rapidly incorporate the fac-[M(I)(CO)3](+) (M = Re, (99m)Tc) core into biological targeting vectors in radiopharmaceuticals continues to expand as molecules become more complex and as efforts to minimize nonspecific binding increase. This work examines a novel isothiocyanate-functionalized bifunctional chelate based on 2,2'-dipicolylamine (DPA) specifically designed for complexing the fac-[M(I)(CO)3](+) core. Two strategies (postlabeling and prelabeling) were explored using the isothiocyanate-functionalized DPA to determine the effectiveness of assembly on the overall yield and purity of the complex with amine containing biomolecules. A model amino acid (lysine) examined (1) amine conjugation of isothiocyanate-functionalized DPA followed by complexation with fac-[M(I)(CO)3](+) (postlabeling) and (2) complexation of fac-[M(I)(CO)3](+) with isothiocyanate-functionalized DPA followed by amine conjugation (prelabeling). Conducted with stable Re and radioactive (99m)Tc analogs, both strategies formed the product in good to excellent yields under macroscopic and radiotracer concentrations. A synthetic peptide (AE105) which targets an emerging biomarker in CaP prognosis, urokinase-type plasminogen activator receptor (uPAR), was also explored using the isothiocyanate-functionalized DPA strategy. In vitro PC-3 (uPAR+) cell uptake assays with the (99m)Tc-labeled peptide (8a) showed 4.2 ± 0.5% uptake at 4 h. In a murine model bearing PC-3 tumor xenografts, in vivo biodistribution of 8a led to favorable tumor uptake (3.7 ± 0.7% ID/g) at 4 h p.i. with relatively low accumulation (<2% ID/g) in normal organs not associated with normal peptide excretion. These results illustrate the promise of the isothiocyanate-functionalized approach for labeling amine containing biological targeting vectors with fac-[M(I)(CO)3](+).
Ashraf, Munis; Sharma, Om Prakash; Priyavadhana, Sruthi; Sambandam, Senthil Nathan; Mounasamy, Varatharaj
2017-01-01
Background: Over the years, proponents of total knee designs (cruciate retaining and posterior stabilised) have conducted several long-term studies to claim the potential of these designs in several subsets of patients. Total knee arthroplasty (TKA) in patients with rheumatoid arthritis has also been one such domain where numerous studies were conducted in the past. A general perception among majority of arthroplasty surgeons is that, posterior stabilised (PS) is the implanted design of choice among patients with Rheumatoid arthritis (RA). However, with the available literature there is a significant disparity related to the selection of implants in patients with rheumatoid RA. In this review of literature, an attempt is made to identify the clinical performance and role of one such implant design, the cruciate retaining (CR) prosthesis in rheumatoid arthritis. Method: The review was conducted after a series of advanced search in the following medical databases; Pub med, Biomed central, Cochrane and Google scholar for articles related to long term follow up studies of cruciate retaining total knee arthroplasty in rheumatoid arthritis using the keywords cruciate retaining prosthesis, total knee arthroplasty, rheumatoid arthritis. Results: The available data demonstrate that the CR design is attributed with an excellent long term survivorship and functional outcome even in follow up studies up to twenty-five years. Conclusion: The advantages of using a CR design are long term survivorship, controlled femoral roll back and preservation of bone stock. Thus, the data gathered in this review lead to a consideration that the CR design is an implant design on par with PS design in patients with RA. PMID:29114338
WE-DE-201-12: Thermal and Dosimetric Properties of a Ferrite-Based Thermo-Brachytherapy Seed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warrell, G; Shvydka, D; Parsai, E I
Purpose: The novel thermo-brachytherapy (TB) seed provides a simple means of adding hyperthermia to LDR prostate permanent implant brachytherapy. The high blood perfusion rate (BPR) within the prostate motivates the use of the ferrite and conductive outer layer design for the seed cores. We describe the results of computational analyses of the thermal properties of this ferrite-based TB seed in modelled patient-specific anatomy, as well as studies of the interseed and scatter (ISA) effect. Methods: The anatomies (including the thermophysical properties of the main tissue types) and seed distributions of 6 prostate patients who had been treated with LDR brachytherapymore » seeds were modelled in the finite element analysis software COMSOL, using ferrite-based TB and additional hyperthermia-only (HT-only) seeds. The resulting temperature distributions were compared to those computed for patient-specific seed distributions, but in uniform anatomy with a constant blood perfusion rate. The ISA effect was quantified in the Monte Carlo software package MCNP5. Results: Compared with temperature distributions calculated in modelled uniform tissue, temperature distributions in the patient-specific anatomy were higher and more heterogeneous. Moreover, the maximum temperature to the rectal wall was typically ∼1 °C greater for patient-specific anatomy than for uniform anatomy. The ISA effect of the TB and HT-only seeds caused a reduction in D90 similar to that found for previously-investigated NiCu-based seeds, but of a slightly smaller magnitude. Conclusion: The differences between temperature distributions computed for uniform and patient-specific anatomy for ferrite-based seeds are significant enough that heterogeneous anatomy should be considered. Both types of modelling indicate that ferrite-based seeds provide sufficiently high and uniform hyperthermia to the prostate, without excessively heating surrounding tissues. The ISA effect of these seeds is slightly less than that for the previously-presented NiCu-based seeds.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hedrick, S; Robison, B; Blakey, M
2016-06-15
Purpose: Rectal hydrogel spacer has been shown to improve rectal sparing in prostate radiotherapy. The purpose of this study was to determine the reproducibility of rectal sparing throughout treatment in patients undergoing proton therapy. Methods: At our facility, prostate cancer patients are treated with pencil beam scanning proton therapy, utilizing an endorectal balloon (ERB) or rectal spacer hydrogel (Gel) “SpaceOAR” implant. All patients were treated with a full bladder and empty rectum (low residue diet and stool softeners). A quality assurance CT (QACT) was performed periodically throughout treatment to ensure rectal filling consistency and sparing in 41 patients treated withmore » Gel. The treatment planning (TP) dose was calculated on each QACT and the rectum V90%, V75%, V65%, V50%, and V40% were recorded. QACT scans were acquired on day 0, week 1, week 3, and week 5. Results: 144 QACT scans were analyzed, each patient receiving 3–4 QACTs. Rectum V90% was within +/−1% of the TP dose in 70% of the QACTs and within +/−5% in 95% of scans. From previous data analyses, our ERB rectum V90% average is 6%. This value was used as an upper threshold for the Gel QACT analysis. 5 of the 41 patients (12%), corresponding to 7 QACTs, had a rectum V90% that exceeded 6% on one or more QACTs. However, the average rectal V90% measured over multiple QACTs never exceeded 6%. 55% of the QACTs had a rectum volume within 5cc of the TPCT volume, 68% were within 10cc. Conclusion: In this study, we have shown that a majority of our prostate patients can maintain consistent rectal sparing when treated with a hydrogel spacer. QACT rectal V90% exceeding our threshold was most often related to increased rectal filling and gas, which was addressed with improved dietary compliance and the intensification of stool softeners or laxatives.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, J; Ghavidel, B; Godette, K
Purpose: To validate a knowledge-based algorithm for prostate LDR brachytherapy treatment planning. Methods: A dataset of 100 cases was compiled from an active prostate seed implant service. Cases were randomized into 10 subsets. For each subset, the 90 remaining library cases were registered to a common reference frame and then characterized on a point by point basis using principle component analysis (PCA). Each test case was converted to PCA vectors using the same process and compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. Themore » seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Any subsequent modifications were recorded that required input from a treatment planner to achieve V100>95%, V150<60%, V200<20%. To simulate operating-room planning constraints, seed activity was held constant, and the seed count could not increase. Results: The computational time required to register test-case contours and evaluate PCA similarity across the library was 10s. Preliminary analysis of 2 subsets shows that 9 of 20 test cases did not require any seed modifications to obtain an acceptable plan. Five test cases required fewer than 10 seed modifications or a grid shift. Another 5 test cases required approximately 20 seed modifications. An acceptable plan was not achieved for 1 outlier, which was substantially larger than its best match. Modifications took between 5s and 6min. Conclusion: A knowledge-based treatment planning algorithm for prostate LDR brachytherapy is being cross validated using 100 prior cases. Preliminary results suggest that for this size library, acceptable plans can be achieved without planner input in about half of the cases while varying amounts of planner input are needed in remaining cases. Computational time and planning time are compatible with clinical practice.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Rachana; Al-Hallaq, Hania; Pelizzari, Charles A.
2003-12-31
The purpose of this study was to compare conventional low-dose-rate prostate brachytherapy dosimetric quality parameters with their biological effective dose (BED) counterparts. To validate a model for transformation from conventional dose to BED, the postimplant plans of 31 prostate brachytherapy patients were evaluated using conventional dose-volume histogram (DVH) quality endpoints and analogous BED-DVH endpoints. Based on CT scans obtained 4 weeks after implantation, DVHs were computed and standard dosimetric endpoints V100 (volume receiving 100% of the prescribed dose), V150, V200, HI (1-[V150/V100]), and D90 (dose that 90% of the target volume received) were obtained for quality analysis. Using known andmore » reported transformations, dose grids were transformed to BED-early ({alpha}/{beta} = 10 Gy) and BED-late ({alpha}/{beta} = 3 Gy) grids, and the same dosimetric endpoints were analyzed. For conventional, BED-early and BED-late DVHs, no differences in V100 were seen (0.896, 0.893, and 0.894, respectively). However, V150 and V200 were significantly higher for both BED-early (0.582 and 0.316) and BED-late (0.595 and 0.337), compared with the conventional (0.539 and 0.255) DVHs. D90 was significantly lower for the BED-early (103.1 Gy) and BED-late transformations (106.9 Gy) as compared with the conventional (119.5 Gy) DVHs. The conventional prescription parameter V100 is the same for the corresponding BED-early and BED-late transformed DVHs. The toxicity parameters V150 and V200 are slightly higher using the BED transformations, suggesting that the BED doses are somewhat higher than predicted using conventional DVHs. The prescription/quality parameter D90 is slightly lower, implying that target coverage is lower than predicted using conventional DVHs. This methodology can be applied to analyze BED dosimetric endpoints to improve clinical outcome and reduce complications of prostate brachytherapy.« less
NASA Astrophysics Data System (ADS)
Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.
2015-10-01
Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solan, Amy N.; Cesaretti, Jamie A.; Stone, Nelson N.
2009-04-01
Purpose: We evaluated the relationship between the onset of erectile dysfunction and dose to the penile bulb and neurovascular bundles (NVBs) after real-time ultrasound-guided prostate brachytherapy. Methods and Materials: One hundred forty-seven patients who underwent prostate brachytherapy met the following eligibility criteria: (1) treatment with {sup 125}I brachytherapy to a prescribed dose of 160 Gy with or without hormones without supplemental external beam radiation therapy, (2) identification as potent before the time of implantation based on a score of 2 or higher on the physician-assigned Mount Sinai Erectile Function Score and a score of 16 or higher on the abbreviatedmore » International Index of Erectile Function patient assessment, and (3) minimum follow-up of 12 months. Median follow-up was 25.7 months (range, 12-47 months). Results: The 3-year actuarial rate of impotence was 23% (34 of 147 patients). An additional 43% of potent patients (49 of 113 patients) were using a potency aid at last follow-up. The penile bulb volume receiving 100% of the prescription dose (V{sub 100}) ranged from 0-0.05 cc (median, 0 cc), with a dose to the hottest 5% (D{sub 5}) range of 12.5-97.9 Gy (median, 40.8 Gy). There was no correlation between penile bulb D{sub 5} or V{sub 100} and postimplantation impotency on actuarial analysis. For the combined right and left NVB structures, V{sub 100} range was 0.3-5.1 cc (median, 1.8 cc), and V{sub 150} range was 0-1.5 cc (median, 0.31 cc). There was no association between NVB V{sub 100} or V{sub 150} and postimplantation impotency on actuarial analysis. Conclusion: Penile bulb doses are low after real-time ultrasound-guided prostate brachytherapy. We found no correlation between dose to either the penile bulb or NVBs and the development of postimplantation impotency.« less
Schwarz, Bettina; Paprottka, Philipp M.; Sourbron, Steven; von Einem, Jobst C.; Dietrich, Olaf; Hinkel, Rabea; Clevert, Dirk A.; Bruns, Christiane J.; Reiser, Maximilian F.; Nikolaou, Konstantin; Wintersperger, Bernd J.
2013-01-01
Abstract Purpose: To investigate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with macromolecular contrast media (MMCM) to monitor the effects of the multikinase inhibitor sorafenib on subcutaneous prostate carcinomas in rats with immunohistochemical validation. Materials and methods: Copenhagen rats, implanted with prostate carcinoma allografts, were randomized to the treatment group (n = 8) or the control group (n = 8). DCE-MRI with albumin-(Gd-DTPA)35 was performed at baseline and after 1 week using a clinical 3-Tesla system. The treatment group received sorafenib, 10 mg/kg body weight daily. Kinetic analysis yielded quantitative parameters of tumor endothelial permeability–surface area product (PS; ml/100 ml/min) and fractional blood volume (Vb, %). Tumors were harvested on day 7 for immunohistochemical analysis. Results: In sorafenib-treated tumors, PS (0.62 ± 0.20 vs 0.08 ± 0.09 ml/100 ml/min; P < 0.01) and Vb (5.1 ± 1.0 vs 0.56 ± 0.48%; P < 0.01) decreased significantly from day 0 to day 7. PS showed a highly significant inverse correlation with tumor cell apoptosis (TUNEL; r = −0.85, P < 0.001). Good, significant correlations of PS were also observed with tumor cell proliferation (Ki-67; r = 0.67, P < 0.01) and tumor vascularity (RECA-1; r = 0.72, P < 0.01). MRI-assayed fractional blood volume Vb showed a highly significant correlation with tumor vascularity (RECA-1; r = 0.87, P < 0.001) and tumor cell proliferation (Ki-67; r = 0.82, P < 0.01). Conclusion: Results of DCE-MRI with MMCM demonstrated good, significant correlations with the immunohistochemically assessed antiangiogenic, antiproliferative, and proapoptotic effects of a 1-week, daily treatment course of sorafenib on experimental prostate carcinoma allografts. PMID:24380871
Extended Generation Profile - E.B.I.C. Model
NASA Astrophysics Data System (ADS)
Guermazi, S.; Toureille, A.; Grill, C.; El Jani, B.; Lakhoua, N.
1996-04-01
We have developed a model for the calculation of the induced current due to an electron beam with an extended profile. As well as the number of absorbed and diffuse electrons as a function of the depth, the generation profile takes into account the lateral diffusion and the effect of defects, dislocations and recombination surfaces. The expression from the Electron Beam Induced Current (EBIC) is obtained by solving the continuity equation in permanent regime by the Green function method. In the case of a Schottky diode Au/InP, obtained by ionic scattering followed by a quick thermal treatment, the induced current profile is compared to the theoretical profiles whose analytical expressions are given by Van Roosbroeck and Bresse. The experimental current profile, measured by S.E.M provided us with the calculation of the diffusion length of the minority carriers, L_n=1 μm. The theoretical curve obtained from the proposed model is in good agreement with the experimental one for a surface recombination velocity of 104 cm s^{-1}. Our results are found to be consistent with those obtained by other experimental techniques on the same samples. Nous avons développé un modèle de calcul du courant induit par un faisceau d'électrons avec un profil de génération élargi. Le profil de génération tient compte, en plus du nombre d'électrons absorbés et du nombre d'électrons diffusés en fonction de la profondeur, de la diffusion latérale (en prenant en considération la diffusion angulaire), de l'effet des défauts, des dislocations et de la recombinaison à la surface. L'expression analytique du courant induit E.B.I.C est déterminée par résolution de l'équation de continuité en régime permanent par la méthode des fonctions de Green. Le profil de courant induit obtenu dans le cas d'une diode Schottky Au/InP dopé p et fabriqué par implantation suivit d'un recuit, est comparé au profil de courant théorique dont l'expression analytique est explicité par Van Roosbroeck et Bresse. Le profil de courant expérimental, mesuré par un microscope électronique à balayage, nous a permis de calculer la longueur de diffusion des porteurs minoritaires L_n=1 μm. La courbe théorique, tracée à partir du modèle proposé, est en bon accord avec la courbe expérimental pour une vitesse de recombinaison à la surface de 104 cm s^{-1}. Ces résultats sont conformes avec ceux obtenus par d'autres techniques expérimentales sur les mêmes échantillons.
A Review of the Surgical Management of Perineal Hernias in Dogs.
Gill, Sukhjit Singh; Barstad, Robert D
2018-05-14
Perineal hernia refers to the failure of the muscular pelvic diaphragm to support the rectal wall, resulting in herniation of pelvic and, occasionally, abdominal viscera into the subcutaneous perineal region. The proposed causes of pelvic diaphragm weakness include tenesmus associated with chronic prostatic disease or constipation, myopathy, rectal abnormalities, and gonadal hormonal imbalances. The most common presentation of perineal hernia in dogs is a unilateral or bilateral nonpainful swelling of the perineum. Clinical signs do occur, but not always. Clinical signs may include constipation, obstipation, dyschezia, tenesmus, rectal prolapse, stranguria, or anuria. The definitive diagnosis of perineal hernia is based on clinical signs and findings of weak pelvic diaphragm musculature during a digital rectal examination. In dogs, perineal hernias are mostly treated by surgical intervention. Appositional herniorrhaphy is sometimes difficult to perform as the levator ani and coccygeus muscles are atrophied and unsuitable for use. Internal obturator muscle transposition is the most commonly used technique. Additional techniques include superficial gluteal and semitendinosus muscle transposition, in addition to the use of synthetic implants and biomaterials. Pexy techniques may be used to prevent rectal prolapse and bladder and prostate gland displacement. Postoperative care involves analgesics, antibiotics, a low-residue diet, and stool softeners.
Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry
NASA Astrophysics Data System (ADS)
Woulfe, P.; Sullivan, F. J.; O'Keeffe, S.
2016-05-01
An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is presented, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 250μm of a 500μm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for brachytherapy, in prostate cancer treatment, providing oncologists with real-time information of the radiation dose to the target area and/or nearby critical structures. The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to Iodine-125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.
Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry
NASA Astrophysics Data System (ADS)
Woulfe, P.; O'Keeffe, S.; Sullivan, F. J.
2018-02-01
An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is developed, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 700μm of a 1mm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for low dose rate (LDR) brachytherapy, in prostate cancer treatment, providing radiation oncologists with real-time information of the radiation dose to the target area and/or nearby organs at risk (OARs). The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to 0.397mCi of Iodine125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.
Crane, Daniel P.; Gromov, Kirill; Li, Dan; Søballe, Kjeld; Wahnes, Christian; Büchner, Hubert; Hilton, Matthew J.; O’Keefe, Regis J.; Murray, Clinton K.; Schwarz, Edward M.
2010-01-01
Summary Osteomyelitis (OM) from multidrug-resistant (MDR) Acinetobacter has emerged in >30% of combat-related injuries in Iraq and Afghanistan. While most of these strains are sensitive to colistin, the drug is not availible in bone void fillers for local high-dose delivery. To address this we developed a mouse model with MDR strains isolated from wounded military personnel. In contrast to S. aureus OM, which is osteolytic and characterized by biofilm in necrotic bone, A. baumannii OM results in blastic lesions that do not contain apparent biofilm. We also found that mice mount a specific IgG response against 3 proteins (40, 47 & 56KDa) regardless of the strain used, suggesting that these may be immunuo-dominant antigens. PCR for the A. baumannii specific parC gene confirmed a 100% infection rate with 75% of the MDR strains, and in vitro testing confirmed that all strains were sensitive to colistin. We also developed a real-time quantitative PCR (RTQ-PCR) assay that could detect as few as 10 copies of parC in a sample. To demonstrate the efficacy of colistin prophylaxis in this model, mice were treated with either parenteral colistin (0.2mg colistinmethate i.m. for 7 days), local colistin (PMMA bead impregnated with 1.0mg colistin sulfate), or an unloaded PMMA bead control. While the parenteral colistin failed to demonstrate any significant effects vs. the placebo, the colistin PMMA bead significantly reduced the infection rate such that only 29.2% of the mice had detectable levels of parC at 19 days (p<0.05 vs. i.m. colistin and placebo). PMID:19173261
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheong, S-K; Kim, J
Purpose: The aim of the study is the application of a Failure Modes and Effects Analysis (FMEA) to access the risks for patients undergoing a Low Dose Rate (LDR) Prostate Brachytherapy Treatment. Methods: FMEA was applied to identify all the sub processes involved in the stages of identifying patient, source handling, treatment preparation, treatment delivery, and post treatment. These processes characterize the radiation treatment associated with LDR Prostate Brachytherapy. The potential failure modes together with their causes and effects were identified and ranked in order of their importance. Three indexes were assigned for each failure mode: the occurrence rating (O),more » the severity rating (S), and the detection rating (D). A ten-point scale was used to score each category, ten being the number indicating most severe, most frequent, and least detectable failure mode, respectively. The risk probability number (RPN) was calculated as a product of the three attributes: RPN = O X S x D. The analysis was carried out by a working group (WG) at UPMC. Results: The total of 56 failure modes were identified including 32 modes before the treatment, 13 modes during the treatment, and 11 modes after the treatment. In addition to the protocols already adopted in the clinical practice, the prioritized risk management will be implanted to the high risk procedures on the basis of RPN score. Conclusion: The effectiveness of the FMEA method was established. The FMEA methodology provides a structured and detailed assessment method for the risk analysis of the LDR Prostate Brachytherapy Procedure and can be applied to other radiation treatment modes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lo, Andrea C.; Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia; Morris, W. James, E-mail: JMorris@bccancer.bc.ca
2014-01-01
Purpose: To determine (1) the prognostic utility of prostate-specific antigen (PSA) concentration at 45 to 60 months (48mPSA) after low-dose-rate prostate brachytherapy (LDR-PB); (2) the predictors of 48mPSA; and (3) the prognostic utility of directional trends between PSA levels at 24, 36, and 48 months after LDR-PB. Methods and Materials: Between 1998 and 2008, 2223 patients with low- and intermediate-risk prostate cancer received LDR-PB monotherapy. A cohort of 1434 of these patients was identified with a documented 48mPSA and no evidence of disease relapse prior to the 48mPSA. In addition, a subset of this cohort (n=585) was identified with ≥72more » months of follow-up and documented PSA values at both 24 and 36 months after implantation. Results: Median follow-up time was 76 months. Eight-year Kaplan-Meier disease-free survival (DFS) rates were 100% vs 73.4% for patients with 48mPSA ≤0.2 vs those with >0.2 ng/mL; 99.1% versus 53.8% for a 48mPSA threshold of ≤0.4 versus >0.4 ng/mL, respectively; and 97.3% versus 0% for a threshold of ≤1.0 versus >1.0 ng/mL, respectively. On multivariate analysis, the only factor predictive of DFS was 48mPSA (P<.0001). On subset analysis (n=585), 29 patients had a PSA rise (defined as >0.2 ng/mL) between 24 and 36 months, 24 patients had a rise between 36 and 48 months, and 11 patients had rises over both intervals. Failure rates in these patients were 52%, 79%, and 100%, respectively. On multivariate analysis, initial PSA, androgen deprivation therapy, and dose to 90% of the prostate significantly correlated with 48mPSA but together accounted for only ∼5% of its total variance. Conclusions: The 48mPSA after LDR-PB is highly predictive of long-term DFS. Patients with 48mPSA ≤0.4 ng/mL had a <1% risk of disease relapse at 8 years, whereas all patients with 48mPSA >1.0 ng/mL relapsed. Consecutive PSA rises of >0.2 ng/mL from 24 to 36 months and from 36 to 48 months were also highly predictive of subsequent failure.« less
Vitrectomy-assisted phacoemulsification for lenticular coloboma.
Agarwal, Ashvin; Narang, Priya; Agarwal, Amar
2017-02-01
We describe a technique to prevent continuous vitreous hydration during phacoemulsification in eyes with lenticular coloboma. The hydration results from communication between the anterior and posterior chambers from the edges of the colobomatous defect. To avoid this, a valved trocar is placed at the pars plana site around the area of the lenticular defect, which allows a limited dry vitrectomy during phacoemulsification. Intermittent vitrectomy with a moderate cutting rate and low vacuum parameters accompanied by temporary halting of the phacoemulsification procedure prevents vitreous herniation into the anterior chamber and limits the extension of zonular compromise, facilitating safe phacoemulsification with appropriate capsule expansion and fixation devices and implantation of an intraocular lens. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macdonald, A. Graham; Keyes, Mira; Kruk, Alexandra
2005-09-01
Purpose: To determine predictive factors for postimplant erectile dysfunction (ED) in a cohort of patients, according to prospectively collected data; specifically, to assess the impact of penile bulb volume and D50 and D95 (dose covering 50% and 95% of the penile bulb volume, respectively) on ED. Methods and Materials: Three hundred forty-two patients were identified who were potent before implant and who had at least 2 years' follow-up. Patient, tumor, treatment, and dosimetric data were collected on all patients. Postimplant ED was defined according to both physician-documented and patient-documented outcome data. Binary logistic regression analysis was used to create multivariablemore » models of predictors for ED at 1, 2, and 3 years after implant. Results: Physician-documented rates of ED were 57%, 48%, and 38% at 1, 2, and 3 years after implant, respectively. Patient-documented rates of ED were 70% and 66% at 1 and 2 years, respectively. Multivariable analyses revealed age and degree of preimplant erectile function to be consistently significant predictors of ED. Use of hormones was significant at the 1-year physician-documented ED endpoint but not thereafter, in keeping with the time course of testosterone recovery. Penile bulb volume, D50, and D95 were not found to be predictive for ED at any time point, in contrast to previous studies. In addition, planning ultrasound target volume, number of needles, and institutional case sequence number were significant predictors of ED at various time points, consistent with a traumatic etiology of ED. Conclusions: We found no evidence to support penile bulb dosimetry as an independent predictive factor for ED after implant, using physician-documented or patient-documented outcomes.« less
Ponnala, Shivani; Veeravalli, Krishna Kumar; Chetty, Chandramu; Dinh, Dzung H; Rao, Jasti S
2011-01-01
Glioblastoma Multiforme (GBM) is the most lethal form of brain tumor. Efficient DNA repair and anti-apoptotic mechanisms are making glioma treatment difficult. Proteases such as MMP9, cathepsin B and urokinase plasminogen activator receptor (uPAR) are over expressed in gliomas and contribute to enhanced cancer cell proliferation. Non-homologous end joining (NHEJ) repair mechanism plays a major role in double strand break (DSB) repair in mammalian cells. Here we show that silencing MMP9 in combination with uPAR/cathepsin B effects NHEJ repair machinery. Expression of DNA PKcs and Ku70/80 at both mRNA and protein levels in MMP9-uPAR (pMU) and MMP9-cathepsin B (pMC) shRNA-treated glioma xenograft cells were reduced. FACS analysis showed an increase in apoptotic peak and proliferation assays revealed a significant reduction in the cell population in pMU- and pMC-treated cells compared to untreated cells. We hypothesized that reduced NHEJ repair led to DSBs accumulation in pMU- and pMC-treated cells, thereby initiating cell death. This hypothesis was confirmed by reduced Ku70/Ku80 protein binding to DSB, increased comet tail length and elevated γH2AX expression in treated cells compared to control. Immunoprecipitation analysis showed that EGFR-mediated lowered DNA PK activity in treated cells compared to controls. Treatment with pMU and pMC shRNA reduced the expression of DNA PKcs and ATM, and elevated γH2AX levels in xenograft implanted nude mice. Glioma cells exposed to hypoxia and irradiation showed DSB accumulation and apoptosis after pMU and pMC treatments compared to respective controls. Our results suggest that pMU and pMC shRNA reduce glioma proliferation by DSB accumulation and increase apoptosis under normoxia, hypoxia and in combination with irradiation. Considering the radio- and chemo-resistant cancers favored by hypoxia, our study provides important therapeutic potential of MMP9, uPAR and cathepsin B shRNA in the treatment of glioma from clinical stand point.
Ponnala, Shivani; Veeravalli, Krishna Kumar; Chetty, Chandramu; Dinh, Dzung H.; Rao, Jasti S.
2011-01-01
Background Glioblastoma Multiforme (GBM) is the most lethal form of brain tumor. Efficient DNA repair and anti-apoptotic mechanisms are making glioma treatment difficult. Proteases such as MMP9, cathepsin B and urokinase plasminogen activator receptor (uPAR) are over expressed in gliomas and contribute to enhanced cancer cell proliferation. Non-homologous end joining (NHEJ) repair mechanism plays a major role in double strand break (DSB) repair in mammalian cells. Methodology/Principal Findings Here we show that silencing MMP9 in combination with uPAR/cathepsin B effects NHEJ repair machinery. Expression of DNA PKcs and Ku70/80 at both mRNA and protein levels in MMP9-uPAR (pMU) and MMP9-cathepsin B (pMC) shRNA-treated glioma xenograft cells were reduced. FACS analysis showed an increase in apoptotic peak and proliferation assays revealed a significant reduction in the cell population in pMU- and pMC-treated cells compared to untreated cells. We hypothesized that reduced NHEJ repair led to DSBs accumulation in pMU- and pMC-treated cells, thereby initiating cell death. This hypothesis was confirmed by reduced Ku70/Ku80 protein binding to DSB, increased comet tail length and elevated γH2AX expression in treated cells compared to control. Immunoprecipitation analysis showed that EGFR-mediated lowered DNA PK activity in treated cells compared to controls. Treatment with pMU and pMC shRNA reduced the expression of DNA PKcs and ATM, and elevated γH2AX levels in xenograft implanted nude mice. Glioma cells exposed to hypoxia and irradiation showed DSB accumulation and apoptosis after pMU and pMC treatments compared to respective controls. Conclusion/Significance Our results suggest that pMU and pMC shRNA reduce glioma proliferation by DSB accumulation and increase apoptosis under normoxia, hypoxia and in combination with irradiation. Considering the radio- and chemo-resistant cancers favored by hypoxia, our study provides important therapeutic potential of MMP9, uPAR and cathepsin B shRNA in the treatment of glioma from clinical stand point. PMID:22022560
Effect of aging and long-term erectile function after iodine-125 prostate brachytherapy.
Keyes, Mira; Pickles, Tom; Crook, Juanita; McKenzie, Michael; Cheung, Arthur; Spadinger, Ingrid; LaPointe, Vincent; Bachand, W Francois; Morris, James
2015-01-01
To evaluate long-term erectile function (EF) in men treated with iodine-125 prostate brachytherapy (PB) and to determine factors predictive for erectile dysfunction (ED), including natural decline because of aging. Two thousand nine hundred twenty-nine patients (implanted July 1989-June 2012) with baseline EF and greater than 10-month followup (FU) are included. About 78.9% had full and 7.9% had partial EF at baseline. EF was assessed on a physician-reported three-point scale. Poisson regression with generalized estimating equations was used to assess predictors of ED and Kaplan-Meier curves time to ED. The effect of aging was calculated from the declining rate of baseline EF seen in sequential 5-year age cohorts and from the Massachusetts Male Aging Study. The median age was 66 years and median FU 3.5 years (maximum 14 years). About 1142 patients had more than 5 years of FU, and 43% had received 6 months of androgen deprivation therapy (ADT). Significant drop in EF was seen at 6 weeks after PB, with gradual decline thereafter. EF preservation at 5 years for age younger than 55, 56-59, 60-64, 65-69, and 70 year and older was 82%, 73%, 58%, 39%, and 23%, respectively. Comparisons of the 5-year age-related and treatment-related EF decline show that 50% of the long-term EF decline is related to aging. On univariate and multivariate analyses, age at implant, length of FU, hypertension, diabetes, and use of ADT (all p < 0.01) were significant predictors of ED. More than 80% of young men have EF preserved 5 years after PB. Age, ADT, history of hypertension, and the natural decline in EF have negative impact on long-term EF after PB. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Directional interstitial brachytherapy from simulation to application
NASA Astrophysics Data System (ADS)
Lin, Liyong
Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the design optimization and construction of the first prototype directional source. Potential clinical applications and potential benefits of directional sources have been shown for prostate and breast tumors.
Ilg, Annette M; Laviana, Aaron A; Kamrava, Mitchell; Veruttipong, Darlene; Steinberg, Michael; Park, Sang-June; Burke, Michael A; Niedzwiecki, Douglas; Kupelian, Patrick A; Saigal, Christopher
Cost estimates through traditional hospital accounting systems are often arbitrary and ambiguous. We used time-driven activity-based costing (TDABC) to determine the true cost of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy for prostate cancer and demonstrate opportunities for cost containment at an academic referral center. We implemented TDABC for patients treated with I-125, preplanned LDR and computed tomography based HDR brachytherapy with two implants from initial consultation through 12-month followup. We constructed detailed process maps for provision of both HDR and LDR. Personnel, space, equipment, and material costs of each step were identified and used to derive capacity cost rates, defined as price per minute. Each capacity cost rate was then multiplied by the relevant process time and products were summed to determine total cost of care. The calculated cost to deliver HDR was greater than LDR by $2,668.86 ($9,538 vs. $6,869). The first and second HDR treatment day cost $3,999.67 and $3,955.67, whereas LDR was delivered on one treatment day and cost $3,887.55. The greatest overall cost driver for both LDR and HDR was personnel at 65.6% ($4,506.82) and 67.0% ($6,387.27) of the total cost. After personnel costs, disposable materials contributed the second most for LDR ($1,920.66, 28.0%) and for HDR ($2,295.94, 24.0%). With TDABC, the true costs to deliver LDR and HDR from the health system perspective were derived. Analysis by physicians and hospital administrators regarding the cost of care afforded redesign opportunities including delivering HDR as one implant. Our work underscores the need to assess clinical outcomes to understand the true difference in value between these modalities. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Conaglen, Helen M; Paul, Ryan G; Yarndley, Tania; Kamp, Jozef; Elston, Marianne S; Conaglen, John V
2014-02-01
Testosterone undecanoate depot (TUD) administered intramuscularly is an effective form of testosterone replacement therapy (TRT) for male hypogonadism. Because of the ease of administration, TUD therapy may be preferable to subcutaneously implanted extended release T pellet implants (TI). The primary objective was to retrospectively assess the efficacy and safety of long-term (≥ 2 years therapy) TUD therapy in the clinical setting. The secondary objective was to retrospectively compare TUD with TI therapy. Retrospective data were collected from the Waikato Hospital Endocrine Database for 179 hypogonadal men treated with TUD for ≥ 2 years from 1998-2011, with 124 of these men receiving previous TI therapy. The main outcome measure for efficacy was serum trough total testosterone (TT), and for safety an increase in hemoglobin (Hb) and/or hematocrit (Hct), rise in prostate-specific antigen (PSA) and/or prostatic biopsy and alteration in body mass index and lipid profile. Additional outcome measures were changes in the dosing and/or interval regimens for TUD therapy. Overall, 72% of trough TT levels were in the normal range for TUD therapy compared with 53% of trough TT levels during TI therapy. TUD therapy was well tolerated with 162 men (90.5%) completing 2 years of treatment, and only seven men (3.9%) stopping TUD because of adverse effects. A rise in Hb and/or Hct occurred in 25 men (14%), and a significant rise in PSA in 20 men (13%) at some stage during TUD therapy. At 2 years, 91% of men received the standard 1,000 mg TUD dose with 66% at the standard dosing interval of 10-14 weekly. TUD is an efficacious, safe, and well tolerated form of TRT, and individual optimisation of the dose and/or interval is only required in the minority of men. Particularly given the ease of administration, TUD was the preferred TRT for both patients and clinicians. © 2013 International Society for Sexual Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mariados, Neil, E-mail: nmariados@ampofny.com; Sylvester, John; Shah, Dhiren
2015-08-01
Purpose: Perirectal spacing, whereby biomaterials are placed between the prostate and rectum, shows promise in reducing rectal dose during prostate cancer radiation therapy. A prospective multicenter randomized controlled pivotal trial was performed to assess outcomes following absorbable spacer (SpaceOAR system) implantation. Methods and Materials: Overall, 222 patients with clinical stage T1 or T2 prostate cancer underwent computed tomography (CT) and magnetic resonance imaging (MRI) scans for treatment planning, followed with fiducial marker placement, and were randomized to receive spacer injection or no injection (control). Patients received postprocedure CT and MRI planning scans and underwent image guided intensity modulated radiation therapymore » (79.2 Gy in 1.8-Gy fractions). Spacer safety and impact on rectal irradiation, toxicity, and quality of life were assessed throughout 15 months. Results: Spacer application was rated as “easy” or “very easy” 98.7% of the time, with a 99% hydrogel placement success rate. Perirectal spaces were 12.6 ± 3.9 mm and 1.6 ± 2.0 mm in the spacer and control groups, respectively. There were no device-related adverse events, rectal perforations, serious bleeding, or infections within either group. Pre-to postspacer plans had a significant reduction in mean rectal V70 (12.4% to 3.3%, P<.0001). Overall acute rectal adverse event rates were similar between groups, with fewer spacer patients experiencing rectal pain (P=.02). A significant reduction in late (3-15 months) rectal toxicity severity in the spacer group was observed (P=.04), with a 2.0% and 7.0% late rectal toxicity incidence in the spacer and control groups, respectively. There was no late rectal toxicity greater than grade 1 in the spacer group. At 15 months 11.6% and 21.4% of spacer and control patients, respectively, experienced 10-point declines in bowel quality of life. MRI scans at 12 months verified spacer absorption. Conclusions: Spacer application was well tolerated. Increased perirectal space reduced rectal irradiation, reduced rectal toxicity severity, and decreased rates of patients experiencing declines in bowel quality of life. The spacer appears to be an effective tool, potentially enabling advanced prostate RT protocols.« less
Constable, Lynda; Cotterill, Nikki; Cooper, David; Glazener, Cathryn; Drake, Marcus J; Forrest, Mark; Harding, Chris; Kilonzo, Mary; MacLennan, Graeme; McCormack, Kirsty; McDonald, Alison; Mundy, Anthony; Norrie, John; Pickard, Robert; Ramsay, Craig; Smith, Rebecca; Wileman, Samantha; Abrams, Paul
2018-02-21
Stress urinary incontinence (SUI) is a frequent adverse effect for men undergoing prostate surgery. A large proportion (around 8% after radical prostatectomy and 2% after transurethral resection of prostate (TURP)) are left with severe disabling incontinence which adversely effects their quality of life and many are reliant on containment measures such as pads (27% and 6% respectively). Surgery is currently the only option for active management of the problem. The overwhelming majority of surgeries for persistent bothersome SUI involve artificial urinary sphincter (AUS) insertion. However, this is expensive, and necessitates manipulation of a pump to enable voiding. More recently, an alternative to AUS has been developed - a synthetic sling for men which elevates the urethra, thus treating SUI. This is thought, by some, to be less invasive, more acceptable and less expensive than AUS but clear evidence for this is lacking. The MASTER trial aims to determine whether the male synthetic sling is non-inferior to implantation of the AUS for men who have SUI after prostate surgery (for cancer or benign disease), judged primarily on clinical effectiveness but also considering relative harms and cost-effectiveness. Men with urodynamic stress incontinence (USI) after prostate surgery, for whom surgery is judged appropriate, are the target population. We aim to recruit men from secondary care urological centres in the UK NHS who carry out surgery for post-prostatectomy incontinence. Outcomes will be assessed by participant-completed questionnaires and 3-day urinary bladder diaries at baseline, 6, 12 and 24 months. The 24-h urinary pad test will be used at baseline as an objective assessment of urine loss. Clinical data will be completed at the time of surgery to provide details of the operative procedures, complications and resource use in hospital. At 12 months, men will also have a clinical review to evaluate the results of surgery (including another 24-h pad test) and to identify problems or need for further treatment. A robust examination of the comparative effectiveness of the male synthetic sling will provide high-quality evidence to determine whether or not it should be adopted widely in the NHS. International Standard Randomised Controlled Trial Registry: Number ISRCTN49212975 . Registered on 22 July 2013. First patient randomised on 29 January 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morton, Gerard C., E-mail: gerard.morton@sunnybrook.ca; Loblaw, D. Andrew; Chung, Hans
Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domainmore » score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose to 10% of the urethra cutpoint for urinary health-related quality of life was 120% of the prescription dose. Conclusion: EPIC was a more sensitive tool for detecting the effects on function and bother than were the generic toxicity scales. The urethral dose had the strongest association with a deteriorating urinary quality of life.« less
SU-E-J-67: Evaluation of Adaptive MLC Morphing for Online Correction of Prostate Cancer Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandhu, R; Qin, A; Yan, D
Purpose: Online adaptive MLC morphing is desirable over translational couch shifts to accommodate target position as well as anatomic changes. A reliable method of adaptive MLC segment to target during prostate cancer IMRT treatment is proposed and evaluated by comparison with daily online-image guidance (IGRT) correction and online-IMRT planning. Methods: The MLC adaptive algorithm involves following steps; move the MLC segments according to target translational shifts, and then morph the segment shape to maintain the spatial relationship between the planning-target contour and MLC segment. Efficacy of this method was evaluated retrospectively using daily-CBCT images on seven prostate patients treated withmore » seven-beam IMRT treatment to deliver 64Gy in 20 fractions. Daily modification was simulated with three approaches; daily-IGRT correction based on implanted radio-markers, adaptive MLC morphing, and online-IMRT planning, with no-residual variation. The selected dosimetric endpoints and nEUD (normalized equivalent uniform dose to online-IMRT planning) of each organ of interest were determined for evaluation and comparison. Results: For target(prostate), bladder and rectal-wall, the mean±sd of nEUD were 97.6%+3.2%, 103.9%±4.9% and 97.4%±1.1% for daily-IGRT correction; and 100.2%+0.2%, 108.9%±5.1% and 99.8%±1.2% for adaptive MLC morphing, respectively. For daily-IGRT correction, adaptive MLC morphing and online-IMRT planning, target D99 was <95% of the prescription dose in 30%, 0% and 0% of 140 fractions, respectively. For the rectal-wall, D5 exceeded 105% of the planned-D5 in 2.8%, 11.4% and 0% of 140 fractions, respectively. For the bladder, Dmax exceeded 105% of the planned-D5 in 2.8%, 5.6% and 0% of 140 fractions, respectively. D30 of bladder and rectal-wall were well within the planned-D30 for all three approaches. Conclusion: The proposed method of adaptive MLC morphing can be beneficial for the prostate patient population with large deformation and rotation. It is superior to the daily-IGRT correction, and comparable to the online-IMRT planning for dose to the target and rectal-wall.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirose, K; Takai, Y; Southern Tohoku BNCT Research Center, Koriyama
2016-06-15
Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostatemore » at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.« less
Mariados, Neil; Sylvester, John; Shah, Dhiren; Karsh, Lawrence; Hudes, Richard; Beyer, David; Kurtzman, Steven; Bogart, Jeffrey; Hsi, R Alex; Kos, Michael; Ellis, Rodney; Logsdon, Mark; Zimberg, Shawn; Forsythe, Kevin; Zhang, Hong; Soffen, Edward; Francke, Patrick; Mantz, Constantine; Rossi, Peter; DeWeese, Theodore; Hamstra, Daniel A; Bosch, Walter; Gay, Hiram; Michalski, Jeff
2015-08-01
Perirectal spacing, whereby biomaterials are placed between the prostate and rectum, shows promise in reducing rectal dose during prostate cancer radiation therapy. A prospective multicenter randomized controlled pivotal trial was performed to assess outcomes following absorbable spacer (SpaceOAR system) implantation. Overall, 222 patients with clinical stage T1 or T2 prostate cancer underwent computed tomography (CT) and magnetic resonance imaging (MRI) scans for treatment planning, followed with fiducial marker placement, and were randomized to receive spacer injection or no injection (control). Patients received postprocedure CT and MRI planning scans and underwent image guided intensity modulated radiation therapy (79.2 Gy in 1.8-Gy fractions). Spacer safety and impact on rectal irradiation, toxicity, and quality of life were assessed throughout 15 months. Spacer application was rated as "easy" or "very easy" 98.7% of the time, with a 99% hydrogel placement success rate. Perirectal spaces were 12.6 ± 3.9 mm and 1.6 ± 2.0 mm in the spacer and control groups, respectively. There were no device-related adverse events, rectal perforations, serious bleeding, or infections within either group. Pre-to postspacer plans had a significant reduction in mean rectal V70 (12.4% to 3.3%, P<.0001). Overall acute rectal adverse event rates were similar between groups, with fewer spacer patients experiencing rectal pain (P=.02). A significant reduction in late (3-15 months) rectal toxicity severity in the spacer group was observed (P=.04), with a 2.0% and 7.0% late rectal toxicity incidence in the spacer and control groups, respectively. There was no late rectal toxicity greater than grade 1 in the spacer group. At 15 months 11.6% and 21.4% of spacer and control patients, respectively, experienced 10-point declines in bowel quality of life. MRI scans at 12 months verified spacer absorption. Spacer application was well tolerated. Increased perirectal space reduced rectal irradiation, reduced rectal toxicity severity, and decreased rates of patients experiencing declines in bowel quality of life. The spacer appears to be an effective tool, potentially enabling advanced prostate RT protocols. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Cha, Ha-Ram; Lee, Joo Hyoung; Hensel, Jonathan A; Sawant, Anandi B; Davis, Brittney H; Lee, Carnellia M; Deshane, Jessy S; Ponnazhagan, Selvarangan
2016-05-01
A growing body of evidence indicates a positive correlation between expression of human antimicrobial peptide leucin leucin 37 (LL-37) and progression of epithelial cancers, including prostate cancer (PCa). Although the molecular mechanisms for this correlation has not yet been elucidated, the primary function of LL-37 as a chemotactic molecule for innate immune effector cells suggests its possible association in coordinating protumorigenic mechanisms, mediated by tumor-infiltrating immune cells. To investigate protumorigenic role(s) of cathelicidin-related antimicrobial peptide (CRAMP), a murine orthologue of LL-37, the present study compared tumor growth kinetics between mouse PCa cell lines with and without CRAMP expression (TRAMP-C1 and TRAMP-C1(CRAMP-sh) , respectively) in immunocompetent mice. CRAMP-mediated chemotaxis of different innate immune cell types to the tumor microenvironment (TME) was observed in vivo and confirmed by in vitro chemotaxis assay. The role of CRAMP in differentiation and polarization of immature myeloid progenitors (IMPs) to protumorigenic type 2 macrophages (M2) in TME was determined by adoptive transfer of IMPs into mice bearing CRAMP(+) and CRAMP(-) tumors. To differentiate protumorigenic events mediated by tumor-derived CRAMP from host immune cell-derived CRAMP, tumor challenge study was performed in CRAMP-deficient mice. To identify mechanisms of CRAMP function, macrophage colony stimulating factor (M-CSF) and monocyte chemoattractant protein 1 (MCP-1) gene expression was analyzed by QRT-PCR and STAT3 signaling was determined by immunoblotting. Significantly delayed tumor growth was observed in wild-type (WT) mice implanted with TRAMP-C1(CRAMP-sh) cells compared to mice implanted with TRAMP-C1 cells. CRAMP(+) TME induced increased number of IMP differentiation into protumorigenic M2 macrophages compared to CRAMP(-) TME, indicating tumor-derived CRAMP facilitates differentiation and polarization of IMPs toward M2. Tumor challenge study in CRAMP deficient mice showed comparable tumor growth kinetics with WT mice, suggesting tumor-derived CRAMP plays a crucial role in PCa progression. In vitro study demonstrated that overexpressed M-CSF and MCP-1 in TRAMP-C1 cells through CRAMP-mediated autocrine signaling, involving p65, regulates IMP-to-M2 differentiation/polarization through STAT3 activation. Altogether, the present study suggests that overexpressed CRAMP in prostate tumor initially chemoattracts IMPs to TME and mediates differentiation and polarization of early myeloid progenitors into protumorigenic M2 macrophages during PCa progression. Thus, selective downregulation of CRAMP in tumor cells in situ may benefit overcoming immunosuppressive mechanisms in PCa. © 2016 Wiley Periodicals, Inc.
Plasmid partition system of the P1par family from the pWR100 virulence plasmid of Shigella flexneri.
Sergueev, Kirill; Dabrazhynetskaya, Alena; Austin, Stuart
2005-05-01
P1par family members promote the active segregation of a variety of plasmids and plasmid prophages in gram-negative bacteria. Each has genes for ParA and ParB proteins, followed by a parS partition site. The large virulence plasmid pWR100 of Shigella flexneri contains a new P1par family member: pWR100par. Although typical parA and parB genes are present, the putative pWR100parS site is atypical in sequence and organization. However, pWR100parS promoted accurate plasmid partition in Escherichia coli when the pWR100 Par proteins were supplied. Unique BoxB hexamer motifs within parS define species specificities among previously described family members. Although substantially different from P1parS from the P1 plasmid prophage of E. coli, pWR100parS has the same BoxB sequence. As predicted, the species specificity of the two types proved identical. They also shared partition-mediated incompatibility, consistent with the proposed mechanistic link between incompatibility and species specificity. Among several informative sequence differences between pWR100parS and P1parS is the presence of a 21-bp insert at the center of the pWR100parS site. Deletion of this insert left much of the parS activity intact. Tolerance of central inserts with integral numbers of helical DNA turns reflects the critical topology of these sites, which are bent by binding the host IHF protein.
Plastic optical fibre sensor for in-vivo radiation monitoring during brachytherapy
NASA Astrophysics Data System (ADS)
Woulfe, P.; Sullivan, F. J.; Lewis, E.; O'Keeffe, S.
2015-09-01
An optical fibre sensor is presented for applications in real-time in-vivo monitoring of the radiation dose a cancer patient receives during seed implantation in Brachytherapy. The sensor is based on radioluminescence whereby radiation sensitive scintillation material is embedded in the core of a 1mm plastic optical fibre. Three scintillation materials are investigated: thallium-doped caesium iodide (CsI:Tl), terbium-doped gadolinium oxysulphide (Gd2O2S:Tb) and europium-doped lanthanum oxysulphide (La2O2S:Eu). Terbium-doped gadolinium oxysulphide was identified as being the most suitable scintillator and further testing demonstrates its measureable response to different activities of Iodine-125, the radio-active source commonly used in Brachytherapy for treating prostate cancer.