Combined tooth-implant-supported telescopic prostheses in a midterm follow-up of > 2 years.
Joda, Tim
2013-01-01
The aim of this trial was to evaluate telescopic-retained prostheses on teeth and implants. Ten patients with a mean of 2.8 teeth received strategic implants to achieve triangular/quadrangular support. Survival and complication rates were estimated for telescopic abutments and prostheses. After a mean observation period of > 2 years, no abutment was lost and all prostheses were in function. Complication rates were low, and maintenance services were limited to minor interventions. Combined tooth-implant-retained telescopic prostheses improve prosthetic support and offer successful function over a midterm period in patients with a severely reduced dentition.
Drago, Carl
2016-08-01
The purpose of this report was to retrospectively evaluate implant and immediate full-arch prosthesis survival rates over a 24-month period; patients were consecutively treated with immediate occlusal loading. Dental arch, gender, and implant orientation (vertical vs. tilted) were also noted. All Brånemark System implants (Nobel Active) and interim, all-acrylic resin prostheses placed in patients following an All-on-Four™ protocol, in a single private practice were assessed by retrospective patient chart review. The amount of space provided surgically for implant restorative components and prostheses was determined from measurements of the vertical heights of the interim prostheses in the right/left anterior and posterior segments. These measurements were made in the laboratory. Interim prosthetic repairs (type, frequency, length of time from insertion) were analyzed by type, arch, gender, and implant orientation. Implant survival and insertion torque values were also measured. Inclusion criteria consisted of all Brånemark System implants placed with the All-on-Four protocol from September 1, 2011, until August 31, 2013. Specific dietary instructions were given for the first 7 days immediately postoperatively and for the weeks prior to insertion of the definitive prostheses. One hundred twenty-nine patients, comprising 191 arches (766 implants) from September 1, 2011, until August 31, 2013, were included in the study. One patient experienced implant failure yielding an overall implant survival rate (SR) of 99.5% (762 of 766). Four hundred twenty-six of 430 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1% and 100%, respectively. Regarding implant orientation, 415 of 417 tilted implants (SR 99.5%) and 343 of 345 (CSR 95.6%) vertical implants were noted to be clinically stable. Interim, all-acrylic resin prostheses were in place for a mean of 199.2 days; mandibular prostheses were in place for an average of 195.4 days; maxillary prostheses were in place for an average of 202.0 days. Thirty four of the 191 interim prostheses (17.8%) warranted at least one repair during the treatment period. The average overall implant insertion torque value was 60.74 Ncm; mandibular torque values averaged 63.08 Ncm; maxillary torque values averaged 59.00 Ncm. The results from this study suggest that dental arch, gender, and implant orientation for implants placed and immediately restored with interim, all-acrylic resin, full-arch prostheses per the All-on-Four protocol did not have significant statistical or clinical effects on prosthetic complications of the interim prostheses or implant survival. Only one of the 129 patients experienced implant failures, indicating that the All-on-Four treatment protocol used in this study is a viable alternative to other protocols for rehabilitating edentulous patients. © 2015 by the American College of Prosthodontists.
Hjalmarsson, Lars; Smedberg, Jan-Ivan; Pettersson, Mattias; Jemt, Torsten
2011-01-01
Long-term comparisons of frameworks at the implant or abutment level are not available, and knowledge of the clinical function of cobalt-chromium (Co-Cr) alloy frameworks is limited. Primarily, the aim of this study was to compare the 5-year clinical performance of frameworks with or without abutment connections to implants. Secondly, the outcomes of prostheses made from Co-Cr alloy with porcelain veneers to those made of commercially pure titanium (CP Ti) with acrylic veneers were compared. The test groups comprised patients treated with screw-retained fixed prostheses made at the implant level according to the Cresco method in either dental porcelain-veneered Co-Cr alloy (n = 15) or acrylic-veneered CP Ti (n = 25). A control group of 40 randomly selected patients were provided with prostheses made at the standard abutment level in CP Ti with acrylic veneers. For all patients, clinical and radiologic 5-year data were retrospectively collected and evaluated. Five-year implant cumulative survival rates (CSRs) were 98.6% and 97.6% for test and control groups, respectively (P > .05). No major differences in bone level were demonstrated between the groups after 5 years (P > .05). Significantly more complications occurred in the test groups compared to the control group (P < .01), with the most common complications being mucositis and fracture of veneers. After 5 years, the clinical outcomes of implant-level prostheses made of porcelain-veneered Co-Cr or acrylic-veneered CP Ti seem comparable to acrylic-veneered titanium prostheses made at the standard abutment level regarding implant CSR and bone levels. However, more complications were registered in implant-level prostheses compared to the standard abutment-level prostheses.
Brieler, H S; Parwaresch, R; Thiede, A
1976-01-01
Our investigations show that Sparks prostheses after subcutaneous implantation are suitable for vascular grafting. At the end of the organization period the connective tissue becomes strong, and after the third and fourth weeks collagenous and elastic fibers can be seen. Ten weeks after s.c. implantation, collagenous fibers predominate. After this the Sparks prostheses can be used as a vascular graft. Intraperitoneal implantation, however, shows a histologically different picture with characteristic findings: only fat cells can be observed, a strong granulation tissue with elastic and collagenous fibers is not present. After intraperitoneal implantation Sparks prostheses are therefore unsuitable for vascular grafts.
Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives.
Rijkhoff, Nico J M
2004-02-01
Neural prostheses are a technology that uses electrical activation of the nervous system to restore function to individuals with neurological or sensory impairment. This article provides an introduction to neural prostheses and lists the most successful neural prostheses (in terms of implanted devices). The article then focuses on neurogenic bladder dysfunction and describes two clinically available implantable neural prostheses for treatment of neurogenic bladder dysfunction. Special attention is given to the usage of these neural prostheses in children. Finally, three new developments that may lead to a new generation of implantable neural prostheses for bladder control are described. They may improve the neural prostheses currently available and expand further the population of patients who can benefit from a neural prosthesis.
Duan, Yonghong; Zhu, Shu; Guo, Fei; Zhu, Jinyu; Li, Mao; Ma, Jie
2012-01-01
Introduction With the increase in joint revision surgery after arthroplasty, defects of hydroxyapatite (HA)-coated prostheses have been observed increasingly often. These defects adversely affect the prosthetic stability in vivo. This study has analyzed the potential effect of the adhesive strength of HA coating on the stability of HA-coated prostheses in vivo after its implantation. Material and methods Sixty experimental rabbits were divided into HA- and Ti-coated groups. HA-coated prostheses were implanted into the bilateral epicondyle of rabbits femurs. Ti-coated prostheses were implanted as control. At different time points(4, 9, and 15 weeks) after implantation, bone tissue samples were fetched out respectively for histomorphometric analysis. Push-out testing was used to detect the ultimate shear strength at the bone-prosthesis interface. Scanning electron microscope (SEM) observation and energy-dispersive X-ray spectroscopy (EDX) analysis were used to observe the changes in surface composition of the prostheses after the ultimate shear strength testing. The coating adhesive strength of two kinds of coatings were also examined by scratch testing. Results Hydroxyapatite coating has an obvious advantage in facilitating osteogenesis and its plays a critical role in the stability of prostheses. However, the ultimate shear strength of HA-coated prostheses is much lower than that of Ti-coated implants (p < 0.01). Further study has demonstrated that the stability of HA-coated prostheses in vivo is affected by the relatively low adhesive strength between coating and substrate. Conclusions Obvious advantage in facilitating osteogenesis around HA-coated prostheses is not the only factor that determines the stability of prostheses in vivo. PMID:22661990
Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.
Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon
2015-01-01
This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.
Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei
2017-02-01
The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.
Clinical Management of Implant Prostheses in Patients with Bruxism
Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao
2012-01-01
There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484
Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina; Ribeiro, Ricardo Faria; de Mattos, Maria G
The aim of this study was to compare the biomechanical performance of splinted or nonsplinted prostheses over short- or regular-length Morse taper implants (5 mm and 11 mm, respectively) in the posterior area of the mandible using finite element analysis. Three-dimensional geometric models of regular implants (Ø 4 × 11 mm) and short implants (Ø 4 × 5 mm) were placed into a simulated model of the left posterior mandible that included the first premolar tooth; all teeth posterior to this tooth had been removed. The four experimental groups were as follows: regular group SP (three regular implants were rehabilitated with splinted prostheses), regular group NSP (three regular implants were rehabilitated with nonsplinted prostheses), short group SP (three short implants were rehabilitated with splinted prostheses), and short group NSP (three short implants were rehabilitated with nonsplinted prostheses). Oblique forces were simulated in molars (365 N) and premolars (200 N). Qualitative and quantitative analyses of the minimum principal stress in bone were performed using ANSYS Workbench software, version 10.0. The use of splinting in the short group reduced the stress to the bone surrounding the implants and tooth. The use of NSP or SP in the regular group resulted in similar stresses. The best indication when there are short implants is to use SP. Use of NSP is feasible only when regular implants are present.
Agile Development of Advanced Prototypes
2014-11-01
prostheses: retinal implants, cochlear implants, and neuroprosthetics (EEG controlled artificial limbs); an interactive, virtual experience...demonstrations allowing users to experience, from a patient’s perspective life with three different prostheses: retinal implants, cochlear implants...three experiences were researched and developed. The applications are interactive demonstrations of retinal implants, cochlear implants, and
Kim, Seok-Gyu; Park, Jae-Uk; Jeong, Jae-Heon; Bae, Chang; Bae, Tae-Soo; Chee, Winston
2009-01-01
The purpose of this study was to evaluate the clinical efficacy of implant prostheses retained by screws and cement (SCPs) by examining the reverse torque values (RTVs) of the abutment screws and the marginal openings of the implant prostheses. Two implants (3.8 x 13 mm; Camlog Biotechnologies) were embedded in an acrylic resin block 5 mm apart. Eighteen copies of this resin specimen were fabricated and randomly divided into two groups. Two-unit implant prostheses with two different designs-purely cement-retained implant prostheses (group 1) and SCPs (group 2)-were made out of type IV gold alloy and placed on the implants. After tightening to about 30 Ncm, the preloading RTVs of the abutment screws were measured. After retightening the abutment screws or cementing the prostheses, followed by cyclic loading, the postloading RTVs of the abutment screws were examined. Also, the marginal openings of the prostheses in the two groups were measured under a stereomicroscope. These measurements were compared statistically. The postloading RTVs and their differences from the preloading RTVs of the abutment screws demonstrated no significant differences between groups (P > .05). Group 2 prostheses showed significantly smaller marginal openings than group 1 prostheses (P < .05). The forces generated when torquing the abutment screw of the SCP did not cause more loosening of the abutment screws than the purely cement-retained implant prosthesis. The SCP showed better marginal adaptation of the cement-retained part than the purely cement-retained implant prosthesis, possibly as a result of the screw-retained abutment seating the restoration. Within the limitations of this in vitro test, the SCP showed no significant difference in RTV of the abutment screw and a smaller marginal gap compared to a purely cement-retained implant prosthesis.
Implant-retained craniofacial prostheses for facial defects
Federspil, Philipp A.
2012-01-01
Craniofacial prostheses, also known as epistheses, are artificial substitutes for facial defects. The breakthrough for rehabilitation of facial defects with implant-retained prostheses came with the development of the modern silicones and bone anchorage. Following the discovery of the osseointegration of titanium in the 1950s, dental implants have been made of titanium in the 1960s. In 1977, the first extraoral titanium implant was inserted in a patient. Later, various solitary extraoral implant systems were developed. Grouped implant systems have also been developed which may be placed more reliably in areas with low bone presentation, as in the nasal and orbital region, or the ideally pneumatised mastoid process. Today, even large facial prostheses may be securely retained. The classical atraumatic surgical technique has remained an unchanged prerequisite for successful implantation of any system. This review outlines the basic principles of osseointegration as well as the main features of extraoral implantology. PMID:22073096
Fritsch, Michael H; Gutt, Jason J
2005-03-01
A 3-T magnetic resonance field may cause motion or displacement of middle ear implants not seen in studies with 1.5-T magnets. Previous publications have described the safety limitations of some otologic implants in 1.5-T magnetic resonance fields. Several company-wide recalls of implants were issued. No studies to date have been reported for otologic implants within a 3-T magnetic resonance field, nor have there been comparisons with a 1.5-T field strength. Eighteen commonly used middle ear implants and prostheses were selected. In Part 1, the prostheses were placed in Petri dishes and exposed to a 3-T magnetic resonance field. In Part 2, the particular prostheses that showed movement in Part 1 were placed into their intended use positions within temporal bone laboratory specimens and exposed to a 3-T field. Both parts were repeated in a 1.5-T field. In Part 1, three prostheses moved dramatically from their start positions when exposed to the 3-T magnetic resonance field. In Part 2, the three particular prostheses that showed movement in Part 1 showed no gross displacement or movement from their start positions within the temporal bone laboratory specimens. No implants moved in the 1.5-T field in either Part 1 or Part 2. Certain stapes prostheses move dramatically in Petri dishes in 3-T fields. When placed into temporal bone laboratory specimens, the same prostheses show no signs of movement from the surgical site in a 3-T field, and it appears that the surgical position holds the implants firmly in place. Results of published 1.5-T field studies should not be used directly for safety recommendations in a 3-T magnetic resonance. Heat, voltage induction, and vibration during exposure to the magnetic resonance fields should be considered as additional possible safety issues. Preference should be given to platinum and titanium implants in manufacturing processes and surgical selection.
Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study.
Duyck, J; Van Oosterwyck, H; Vander Sloten, J; De Cooman, M; Puers, R; Naert, I
2001-03-01
The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the 'optimal fit' situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P < 0.02). The induced bending moments after tightening the prostheses were statistically significantly higher (P < 0.0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.
Within-subject comparisons of implant-supported mandibular prostheses: psychometric evaluation.
de Grandmont, P; Feine, J S; Taché, R; Boudrias, P; Donohue, W B; Tanguay, R; Lund, J P
1994-05-01
In a within-subject cross-over clinical trial, psychometric and functional measurements were taken while 15 completely edentulous subjects wore mandibular fixed prostheses and long-bar removable implant-supported prostheses. In this paper, the results of a psychometric assessment are presented. Eight subjects first received the fixed bridge and seven the removable type. After having worn a prosthesis for a minimum of two months, subjects responded to psychometric scales that measured their perceptions of various factors associated with prostheses. They also chewed test foods while masticatory activity was recorded. The prostheses were then changed and the procedures repeated. At the end of the study, patients were asked to choose the prosthesis that they wished to keep. Patients assigned significantly higher scores, on visual analogue scales, to both types of implant-supported prostheses than to their original conventional prostheses for all factors tested, including general satisfaction. However, no statistically significant differences between the two implant-supported prostheses were detected except for the difficulty of chewing carrot, apple, and sausage. For these foods, the fixed prostheses were rated higher. Subjects' responses to category scales were consistent with their responses to the visual analogue scales. These results suggest that, although patients find the fixed bridge to be significantly better for chewing harder foods, there is no difference in their general satisfaction with the two types of prostheses.
Loza-Herrero, María A; Rivas-Tumanyan, Sona; Morou-Bermudez, Evangelia
2015-11-01
The success rate of implant-retained prostheses in a postdoctoral prosthodontics program was unknown and could not be related to any set of potential clinical issues or patient characteristics. The purpose of this study was to determine the success rate of implant-retained prostheses placed by prosthodontic residents between 1997 and 2012 and to evaluate the associations between patient classifications and specific restoration characteristics as related to prosthesis success or failure. A total of 272 prostheses in 119 patients were clinically evaluated. Success was defined as the absence of prosthetic complications or any implant-related complication that affected prosthesis survival. Logistic regression was used to evaluate associations between prosthesis success/failure and a wide array of study variables, adjusting for patient age, sex, and prosthesis longevity. The overall success rate was 71%, with a mean prosthesis age of 4.5 years (range: 4 months to 16.8 years). Implant single crowns were the most successful prosthesis type (81% success). The most common complications observed were porcelain fractures in fixed dental prostheses (15%) and lack of stability (31%) and retention (29%) in removable dental prostheses. Having a removable prosthesis (versus natural dentition) in the opposing occlusion significantly decreased the odds of success (OR=0.26, 95% CI: 0.11-0.64). Definitively cemented fixed prostheses were more successful than those cemented with an interim cement (OR=4.56, 95% CI: 1.37-15.22). The overall success rate of the implant-retained prostheses placed in the program was low compared with previously published studies. This study revealed the need for an efficient, comprehensive recall system for patients receiving implant-retained prostheses, either fixed or removable. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.
Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio
2009-01-01
Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.
In vivo testing of porous Ti-25Nb alloy serving as a femoral stem prosthesis in a rabbit model
Weng, Xiaojun; Yang, Hailin; Xu, Jian; Li, Xiaosheng; Liao, Qiande; Wang, Jing
2016-01-01
The aim of the present study was to observe the performance of Ti-25Nb alloys with various porosities as femoral stem prostheses in a rabbit model, thus providing basic experimental evidence for the development of porous prostheses. The porous Ti-25Nb alloy prostheses were designed according to the morphology of the medullary cavity. These prostheses were placed into the femoral medullary cavities in 36 New Zealand white rabbits. Postoperative X-ray films, scanning electron microscopy (SEM) of the implant interface, energy-dispersive spectroscopy (EDS) analysis of the implant surface, pulling-out test and general observations were conducted. The specimens showed good biocompatibility; there was no obvious bone absorption in porous Ti-25Nb specimens with different porosities at different time points observed using X-ray films. Under SEM examination, calcium deposits were observed inside the pores and in the interface between bone and prostheses. The EDS analysis demonstrated that calcium deposits were present on the surface of the prostheses at the eight-week point postoperatively. The pulling-out test showed good bonding strength between bone and implant; after pulling out, the surface and inside the pores of the prostheses all presented bone mass. Porous Ti-25Nb alloy implants presents good biocompatibility as well as providing a biological fixation between the bone and implant. A porosity of 70% is more advantageous to the newborn bone ingrowth, combined with achieving a more solid bone-implant interface. PMID:27602063
Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Batista, Victor Eduardo de Souza; Noritomi, Pedro Yoshito; Pellizzer, Duardo Piza
2018-01-01
The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.
Maló, Paulo; Nobre, Miguel de Araújo; Lopes, Armando; Ferro, Ana; Gravito, Inês
2014-01-01
To report the 5-year outcome of immediately loaded dental implants in patients with untreated periodontal disease. This prospective cohort study included 103 consecutive patients (51 females and 52 males) with an average age of 52 years (range: 22 to 80 years) who were rehabilitated with 380 implants supporting 145 prostheses in both jaws (40 single; 33 partial and 72 complete rehabilitations). The implants were inserted in patients with active and untreated periodontitis. The patients did not receive any previous periodontal treatment before implant surgery, except for an oral hygiene session immediately before the implant surgery. In maintenance (every 6 months) patients received periodontal treatment as needed. Outcome measures were: prostheses failures; implant failures; complications; and marginal bone level changes. Fifteen patients dropped out of the study (14.6%). Two patients lost two implants (FDI positions nos.12 and 42), rendering a cumulative survival rate of 97.9% and 99.4% at 5 years of followup using the patient and implant as unit of analysis, respectively. The average (standard deviation) marginal bone resorption was 0.71 mm (0.42 mm) at 5 years. Mechanical complications occurred in 14 patients, consisting of prostheses fractures (10 provisional prostheses and 4 definitive prostheses). Thirteen implants (3.9%) in 13 patients (14.8%) presented peri-implant pathology. Within the limitations of this study, it is possible to conclude that the rehabilitation of patients with untreated periodontitis using immediately loaded dental implants is feasible in the medium-term, when periodontal therapy is provided after rehabilitation and the patients are regularly maintained.
Ortorp, A; Jemt, T
1999-01-01
Titanium frameworks have been used in the endentulous implant patient for the last 10 years. However, knowledge of titanium frameworks for the partially dentate patient is limited. To report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw. A consecutive group of 383 partially edentulous patients were, on a routine basis, provided with fixed partial prostheses supported by Brånemark implants in the mandible or maxilla. Besides conventional frameworks in cast gold alloy, 58 patients were provided with titanium frameworks with three different veneering techniques, and clinical and radiographic 5-year data were collected for this group. The overall cumulative survival rate was 95.6% for titanium-framework prostheses and 93.6% for implants. Average bone loss during the follow-up period was 0.4 mm. The most common complications were minor veneering fractures. Loose and fractured implant screw components were fewer than 2%. An observation was that patients on medications for cardiovascular problems may lose more implants than others (p < .05). The clinical performance of prostheses with implant-supported laser-welded titanium frameworks was similar to that reported for conventional cast frames in partially edentulous jaws. Low-fusing porcelain veneers also showed clinical performance comparable to that reported for conventional porcelain-fused-to-metal techniques.
Zanolla, Jaine; Amado, Flávio Monteiro; da Silva, Willian Saranholi; Ayub, Bruno; de Almeida, Ana Lúcia Pompéia Fraga; Soares, Simone
2016-01-01
Background: The prosthetic treatment in cleft patients is challenging. Based on this, the aim of this study was to evaluate the longevity of prosthetic rehabilitation treatment with implant-supported overdenture (IOD) and implant-supported fixed denture (IFD) in cleft lip and palate patients in a period of 22 years. Materials and Methods: The medical records of 72 patients were analyzed (29 males and 43 females), and the survival rate of the implants was evaluated. Moreover, the prostheses’ time of use and the reason for the changing of these were also evaluated. Results: Four-hundred-seventeen implants were installed, and 370 implants survive today. The mean survival time of the implants was 7.6 years. Regarding the 97 prostheses made, the time of average use was 3.28 for the IFDs and 3.92 for IODs. The reasons for the replacements of the prostheses were mainly: fracture of the acrylic base (29.6%) and loss of vertical dimension of occlusion (VDO) (18.5%) in the IFDs. Moreover, in IODs, these were accounted for the loss of VDO due to teeth damage (17.2%) and implant loss (14.6%). Conclusions: The maintenance of the prostheses was challenging because the patients had difficulties returning for periodic control, but this fact did not result in the decrease of the success rate of the implants. The longevity of implants and prostheses was satisfactory; however, the prostheses showed repetitions mainly due to the wear of the teeth, with decreased vertical dimension and fracture of acrylic base. PMID:28299262
[Design and optimization of wireless power and data transmission for visual prosthesis].
Lei, Xuping; Wu, Kaijie; Zhao, Lei; Chai, Xinyu
2013-11-01
Boosting spatial resolution of visual prostheses is an effective method to improve implant subjects' visual perception. However, power consumption of visual implants greatly rises with the increasing number of implanted electrodes. In respond to this trend, visual prostheses need to develop high-efficiency wireless power transmission and high-speed data transmission. This paper presents a review of current research progress on wireless power and data transmission for visual prostheses, analyzes relative principles and requirement, and introduces design methods of power and data transmission.
Design features of implants for direct skeletal attachment of limb prostheses
Pitkin, M.
2013-01-01
In direct skeletal attachment (DSA) of limb prostheses, a construct is implanted into an amputee’s residuum bone and protrudes out of the residuum’s skin. This technology represents an alternative to traditional suspension of prostheses via various socket systems, with clear indications when the sockets cannot be properly fitted. Contemporary DSA was invented in the 1990s, and several implant systems have been introduced since then. The current review is intended to compare the design features of implants for DSA whose use in humans or in animal studies has been reported in the literature. PMID:23554122
El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia
2017-04-01
Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value <0.05). Our study has shown an enhancement in the quality of life and the nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
[On the history of cementless implants in extremity surgery].
Dufek, Pavel
2017-05-01
The aim of implantation of cementless hip prostheses is vital ingrowth of bone into the structured metal surface of the implant. Since the 1960s several implants with surfaces made of cobalt-based alloys have been produced for this purpose. In the 1980s a novel hip endoprosthesis with a spongiosa-metal surface was introduced. The three-dimensional ingrowth of bone tissue into the structured surface of the implant could be demonstrated both histologically and using scanning electron microscopy (SEM). These implants made of cobalt-based alloys can also be used in endo-exo prostheses. Titanium implants with a microstructured surface have also been used and very good osseintegration of the surface was also demonstrated by histomorphology. The optimization of the surface and design of the prostheses plays an increasingly more important role in the field of revision endoprostheses.
Lipsker, A; Saljoghi, R; Lecuelle, D; Caillet, K; Alezra, E; Le Roux, F; Demailly, M; Saint, F
2016-09-01
Patients who are not responding to injectable and/or vacuum oral pharmacological treatments can receive a penile prosthesis. Three types of penile prostheses are used in France: rigid, semi-rigid and inflatable prostheses 3-piece or 2-piece. We have assessed the National surgical insertion practices between 2006 and 2013 (number of prostheses insertions, types, procedure locations, number of surgeons and distribution [public or private sectors]). Data analysis from the French Technical Agency of Information on Hospitals (ATIH) (2006-2013) using the common classification of medical acts (CCAM) and after code extractions related to this surgery (JHLA002, JHLA003, JHLA004). Between 2006 and 2013, the number of penile implants in France doubled (307 to 633), inflatable penile prostheses with an extracavernous component remained the most frequently used (87 %) (228 to 552) (+142 %). The use of semi-rigid prostheses declined by 26.7 %. The distribution between the private and public sector was close to 1 in 2013. More than half of French penile prostheses were implanted in three regions (Île-de-France, Languedoc-Roussillon, Rhône-Alpes). Nearly 62 % of surgeons implanted only one or two three-compartment prostheses in 2013. The number of penile prostheses in France doubled between 2006 and 2013. Three regions were particularly active as far as this surgery is concerned (Île-de-France, Languedoc-Roussillon, Rhône-Alpes). They were boosted by 5 surgeons with more than 20 prostheses surgeries a year. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Hip prostheses in young adults. Surface prostheses and short-stem prostheses.
Gallart, X; Riba, J; Fernández-Valencia, J A; Bori, G; Muñoz-Mahamud, E; Combalia, A
The poor results obtained in young patients when using a conventional prosthesis led to the resurgence of hip resurfacing to find less invasive implants for the bone. Young patients present a demand for additional activity, which makes them a serious challenge for the survival of implants. In addition, new information technologies contribute decisively to the preference for non-cemented prostheses. Maintaining quality of life, preserving the bone and soft tissues, as well as achieving a very stable implant, are the goals of every hip orthopaedic surgeon for these patients. The results in research point to the use of smaller prostheses, which use the metaphyseal zone more and less the diaphyseal zone, and hence the large number of the abovementioned short stem prostheses. Both models are principally indicated in the young adult. Their revision should be a more simple operation, but this is only true for hip resurfacing, not for short stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Isaksson, Rita; Becktor, Jonas P; Brown, Andrew; Laurizohn, Christer; Isaksson, Sten
2009-12-01
The aim of this study was to investigate oral health and oral implant status in a group of edentulous patients receiving long-term residential or nursing care (LTC), all of whom had implant-supported fixed or removable dental prostheses. A dental examination was performed on a total of 3310 patients receiving LTC and from this population 35 edentulous patients in whom dental implants had been placed formed the cohort for this study. All examinations were performed by a specialist in hospital dentistry and took place in the patients' own home environment. Oral health was assessed by means of a protocol which evaluated oral hygiene status, possible oral mucosal inflammation and oral mucosal friction levels. Any problems with the implant-supported prosthesis, implant mobility or other complications were also assessed. In addition, patients were asked about any oral symptoms and their usual oral hygiene procedures. About half of the subjects (17/35) were registered as having no/mild inflammation with 18 of 35 having moderate/severe inflammation. Twelve of the 35 patients had good/acceptable oral hygiene and 23 of 35 had poor/bad oral hygiene. Twenty-one of the 35 patients depended on help from the nursing personnel for their daily oral hygiene procedures. Obvious problems with food impaction were noted in 11 patients. A total of 229 implants had been placed in 43 jaws supporting 40 full arch-fixed prostheses and three implant-borne overdentures. There was no evidence of mobility or fractures of either the implants or the prostheses. Fifteen implants showed some exposed screw threads. Pus was exuding from one implant site and general peri-implant gingival hyperplasia was noted in two patients. Twenty-four patients were completely satisfied with the function and appearance of their implant-supported prostheses. Two patients were totally dissatisfied. This study indicates that oral implant therapy can be considered as a treatment of choice in elderly patients, even if oral hygiene is sub-optimal.
Prevalence of peri-implantitis in patients with implant-supported fixed prostheses.
Schuldt Filho, Guenther; Dalago, Haline Renata; Oliveira de Souza, João Gustavo; Stanley, Kyle; Jovanovic, Sascha; Bianchini, Marco Aurélio
2014-01-01
The purpose of this study was to evaluate periimplantitis prevalence in patients using implant-supported fixed prostheses that did not have any routine maintenance care. A total of 161 implants (27 patients) were evaluated in patients using implant-supported fixed prostheses. Collected data included information related to patient general health and local factors such as characteristics of implants, time in function, type of loading, positioning, Modified Bleeding Index, bacterial plaque, bleeding on probing (BOP), marginal recession, probing depth (PD), keratinized mucosa, and radiographic bone loss (BL). Factors related to the prostheses were also evaluated. The exclusion criteria were patients that have had any follow-up visit for plaque control of the prosthesis and/or the implants. From a total of 161 implants, 116 (72%) presented without peri-implantitis (PD > 4 mm + BOP + BL > 2 mm) while 45 (28%) had some sign of the disease. Implants placed in the maxilla were 2.98 times more likely to develop the disease (P < .05). Moreover, patients aged ≤ 60 years old were 3.24 times more likely to develop peri-implantitis (P < .05). Another analysis with statistical relevance (P < .05) was that implants with less than 3 mm interimplant distance were three times more likely to have peri-implantitis. There was no statistical relevance considering other analyses. It can be concluded that patients aged ≤ 60 years have a greater chance of presenting periimplantitis, as well as for implants positioned in the maxilla and those placed with an interimplant distance < 3 mm.
Robotic cadaver testing of a new total ankle prosthesis model (German Ankle System).
Richter, Martinus; Zech, Stefan; Westphal, Ralf; Klimesch, Yvone; Gosling, Thomas
2007-12-01
An investigation was carried out into possible increased forces, torques, and altered motions during load-bearing ankle motion after implantation of two different total ankle prostheses. We hypothesized that the parameters investigated would not differ in relation to the two implants compared. We included two different ankle prostheses (Hintegra, Newdeal, Vienne, France; German Ankle System, R-Innovation, Coburg, Germany). The prostheses were implanted in seven paired cadaver specimens. The specimens were mounted on an industrial robot that enables complex motion under predefined conditions (RX 90, Stäubli, Bayreuth, Germany). The robot detected the load-bearing (30 kg) motion of the 100(th) cycle of the specimens without prostheses as the baseline for the later testing, and mimicked that exact motion during 100 cycles after the prostheses were implanted. The resulting forces, torques, and bone motions were recorded and the differences between the prostheses compared. The Hintegra and German Ankle System, significantly increased the forces and torques in relation to the specimen without a prosthesis with one exception (one-sample-t-test, each p < or = 0.01; exception, parameter lateral force measured with the German Ankle System, p = 0.34). The force, torque, and motion differences between the specimens before and after implantation of the prostheses were lower with the German Ankle System than with the Hintegra (unpaired t-test, each p < or = 0.05). The German Ankle System prosthesis had less of an effect on resulting forces and torques during partial weightbearing passive ankle motion than the Hintegra prosthesis. This might improve function and minimize loosening during the clinical use.
Implants for elderly patients.
Schimmel, Martin; Müller, Frauke; Suter, Valérie; Buser, Daniel
2017-02-01
In the developed world, the large birth cohorts of the so-called baby boomer generation have arrived in medical and dental practices. Often, elderly patients are 'young-old' baby boomers in whom partial edentulism is the predominant indication for implant therapy. However, the generation 85+ years of age represents a new challenge for the dental profession, as their lives are frequently dominated by dependency, multimorbidity and frailty. In geriatric implant dentistry, treatment planning is highly individualized, as interindividual differences become more pronounced with age. Nevertheless, there are four typical indications for implant therapy: (i) avoidance of removable partial prostheses; (ii) preservation of existing removable partial prostheses; (iii) stabilization of Kennedy Class I removable partial prostheses; and (iv) stabilization of complete prostheses. From a surgical point of view, two very important aspects must be considered when planning implant surgery in elderly patients: first, the consistent strive to minimize morbidity; and, second, the fact that coexisting medical risk factors are significantly more common in elderly patients. Modern three-dimensional cone beam computed tomography imaging is often indicated in order to plan minimally invasive implant surgery. Computer-assisted implant surgery might allow flapless implant surgery, which offers a low level of postoperative morbidity and a minimal risk of postsurgical bleeding. Short and reduced-diameter implants are now utilized much more often than a decade ago. Two-stage surgical procedures should be avoided in elderly patients. Implant restorations for elderly patients should be designed so that they can be modified to become low-maintenance prostheses, or even be removed, as a strategy to facilitate oral hygiene and comfort in the final stage of life. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fottner, Andreas; Schmid, Markus; Birkenmaier, Christof; Mazoochian, Farhad; Plitz, Wolfgang; Volkmar, Jansson
2009-06-01
Stemless and short-stemmed hip prostheses have been developed to preserve femoral bone stock. While all these prostheses claim a more or less physiological load transfer, clinical long-term results are only available for the stemless thrust plate prosthesis. In this study, the in vitro primary stability of the thrust plate prosthesis was compared to two types of short-stemmed prostheses. In addition to the well-established Mayo prosthesis, the modular Metha prosthesis was tested using cone adapters with 130 degrees and 140 degrees neck-shaft-angles. The prostheses were implanted in composite femurs and loaded dynamically (300-1700 N). Three-dimensional micromotions at the bone-prosthesis interface were measured. In addition, the three-dimensional deformations at the surface of the composite femur were measured to gain data on the strain distribution. For all tested prostheses, the micromotions did not exceed 150 microm, the critical value for osteointegration. The thrust plate prosthesis revealed similar motions as the short-stemmed prostheses. The short-stemmed prosthesis with the 130 degrees cone tended to have the highest micromotions of all tested short-stemmed prostheses. The thrust plate prosthesis revealed the lowest alteration of bone surface deformation after implantation. The comparably low micromotions of the thrust plate prosthesis and the short-stemmed prostheses should be conducive to osseous integration. The higher alteration of load transmission after implantation reveals a higher risk of stress shielding for the short-stemmed prostheses.
Sohn, Dong-Seok; Kim, Woo-Sung; Lee, Won-Hyuk; Jung, Heui-Seung; Shin, Im-Hee
2010-10-01
The aim of this retrospective study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of 9 years of functioning (mean: 55.8 months; range: 5-108 months). The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and 1 private dental clinic. A total of 122 sintered porous-surfaced implants--Endopore (Innova Life Sciences, Toronto, Ontario, Canada)--were placed in the edentulous posterior mandibles. Two diameter sizes (4.1 and 5.0 mm) and 4 lengths (5.0, 7.0, 9.0, and 12.0 mm) were used. All implants were restored with fixed prostheses. One hundred three implants were splinted and 21 implants were nonsplinted. Panoramic views and periapical radiographs were taken at the time of the first, postoperative, crown placement, and following checkup visits. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the χ² test. The survival rate of the 4.1-mm-diameter implants was 100% and 91.2% for the 5.0-mm-diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (P = 0.005). The survival rates of both the 5.0-mm and 7.0-mm-length implants were 100%. The survival rate of the 9.0-mm-length implants was 97.9% and for the 12.0-mm-length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the nonsplinted prostheses but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was <1.0. When the crown-to-implant ratio was between 1.0 and 1.4, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (P = 0.048). The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of 9 years of functioning in the edentulous posterior mandibles.
Esteban, J; Alvarez-Alvarez, B; Blanco, A; Fernández-Roblas, R; Gadea, I; Garcia-Cañete, J; Sandoval, E; Valdazo, M
2013-07-01
We have designed a prospective study to evaluate the usefulness of prolonged incubation of cultures from sonicated orthopaedic implants. During the study period 124 implants from 113 patients were processed (22 osteosynthetic implants, 46 hip prostheses, 54 knee prostheses, and two shoulder prostheses). Of these, 70 patients had clinical infection; 32 had received antibiotics at least seven days before removal of the implant. A total of 54 patients had sonicated samples that produced positive cultures (including four patients without infection). All of them were positive in the first seven days of incubation. No differences were found regarding previous antibiotic treatment when analysing colony counts or days of incubation in the case of a positive result. In our experience, extending incubation of the samples to 14 days does not add more positive results for sonicated orthopaedic implants (hip and knee prosthesis and osteosynthesis implants) compared with a conventional seven-day incubation period.
Ferrario, Virgilio F; Tartaglia, Gianluca M; Maglione, Michele; Simion, Massimo; Sforza, Chiarella
2004-04-01
To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.
Fiber-reinforced composite fixed dental prostheses: two clinical reports.
Zarow, Maciej; Paisley, Carl Stuart; Krupinski, Jerzy; Brunton, Paul Anthony
2010-06-01
Various options are available in clinical practice for the replacement of a single missing tooth, ranging from conventional fixed and removable dental prostheses to a single implant-supported crown. There are situations in which a semipermanent fixed dental prosthesis may be desirable, particularly for patients who have completed orthodontic treatment but are too young to embark on implant therapy. Following advances in fiber-reinforcement technology, fiber-reinforced composite resin (FRC) now represents a lower-cost alternative to traditional metal-ceramic for the construction of resin-bonded prostheses. Two case reports illustrate the use of FRC prostheses as fixed semipermanent_restorations.
Occlusal contact of fixed implant prostheses using functional bite impression technique.
Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro
2015-02-01
Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.
Zou, Duohong; Wu, Yiqun; Wang, Xu Dong; Huang, Wei; Zhang, Zhiyong; Zhang, Zhiyuan
2014-10-01
The aim of this study was to evaluate oral function rehabilitation in patients with hypohidrotic ectodermal dysplasia (HED) using implant-supported prostheses based on bone augmentation. From September 2005 and March 2009, 25 HED patients were chosen for clinical data analysis in this study. The criteria for patient selection included the following: the display of clinical features of HED, the number of congenitally missing teeth (>5), the patient age (>16 years), the patient's willingness, and the patient's tolerance for bone graft surgery and implant placement. Follow-up evaluations were initiated from the time of implant prosthetic placement and scheduled annually for 3-5 years. The effects of oral function reconstruction were assessed based on the cumulative survival and success rates of implants, the health of the peri-implant area, and the degree of patient satisfaction. Twenty-five HED patients received 169 conventional implants and 10 zygomatic implants (179 total implants). During 3-5 years of post-loading evaluations, 5 of the 179 implants failed and 3 implants were removed. The 3-year success and cumulative survival rates were 97.2% and 98.3%, respectively. Furthermore, periodontal probing and radiographic assessments showed that the 3-year incidence of peri-implantitis was 4.5%. Finally, HED patients expressed high degrees of satisfaction with their facial contours, masticatory function, pronunciation ability, and comfort with the implant-supported prostheses. The results of this 3- to 5-year retrospective study indicate that the oral function of HED patients can be effectively reconstructed using bone augmentation and implant-supported prostheses; however, longer term results are warranted in the future.
Implant-supported titanium prostheses following augmentation procedures: a clinical report.
Knabe, C; Hoffmeister, B
2003-03-01
This report describes a novel technique for fabricating retrievable implant-supported titanium (Ti) prostheses in patients requiring a comprehensive treatment plan involving the combined efforts of maxillofacial surgery and implant prosthodontics. Following bone graft reconstructive surgery and implant placement prosthetic treatment was initiated by inserting ITI-Octa abutments. An impression was made, and a framework was fabricated by fusing Ti-cast frameworks to prefabricated titanium copings by laser-welding. This was followed by veneering or fabrication of a removable denture with Ti metal re-enforcement. Favourable clinical results have been achieved using these screw-retained Ti implant-supported restorations for patients treated with reconstructive bone graft-surgery, with clinical observation periods ranging from three to four years. The present observations suggest that these screw-retained implant-supported Ti prostheses may be a meaningful contribution to implant prosthodontics, facilitating retrievable restorations of optimum biocompatibility, good marginal precision and with a good esthetic result. However, controlled clinical studies are needed to establish the long-term serviceability of these Ti restorations.
Polyurethane-covered mammary implants: a 12-year experience.
Gasperoni, C; Salgarello, M; Gargani, G
1992-10-01
Polyurethane-covered mammary implants are the implants of choice in aesthetic and reconstructive mammary surgery. These implants give very good results in regard to breast contour and consistency, and have a very low complication rate. We present our 12-year experience using polyurethane-covered prostheses. We place the implant mostly in the subglandular or subcutaneous site, and their capsular contracture rate is extremely low (3.3%). Based on our experience, we also review the other complications and side effects occurring with polyurethane prostheses and discuss them in detail.
Örtorp, Anders; Jemt, Torsten
2012-03-01
No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.
Fracture analysis of randomized implant-supported fixed dental prostheses
Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.
2014-01-01
Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and lighter contacts than ones supported by natural dentition. PMID:25016139
Quantification of dental prostheses on cone‐beam CT images by the Taguchi method
Kuo, Rong‐Fu; Fang, Kwang‐Ming; TY, Wong
2016-01-01
The gray values accuracy of dental cone‐beam computed tomography (CBCT) is affected by dental metal prostheses. The distortion of dental CBCT gray values could lead to inaccuracies of orthodontic and implant treatment. The aim of this study was to quantify the effect of scanning parameters and dental metal prostheses on the accuracy of dental cone‐beam computed tomography (CBCT) gray values using the Taguchi method. Eight dental model casts of an upper jaw including prostheses, and a ninth prosthesis‐free dental model cast, were scanned by two dental CBCT devices. The mean gray value of the selected circular regions of interest (ROIs) were measured using dental CBCT images of eight dental model casts and were compared with those measured from CBCT images of the prosthesis‐free dental model cast. For each image set, four consecutive slices of gingiva were selected. The seven factors (CBCTs, occlusal plane canting, implant connection, prosthesis position, coping material, coping thickness, and types of dental restoration) were used to evaluate scanning parameter and dental prostheses effects. Statistical methods of signal to noise ratio (S/N) and analysis of variance (ANOVA) with 95% confidence were applied to quantify the effects of scanning parameters and dental prostheses on dental CBCT gray values accuracy. For ROIs surrounding dental prostheses, the accuracy of CBCT gray values were affected primarily by implant connection (42%), followed by type of restoration (29%), prostheses position (19%), coping material (4%), and coping thickness (4%). For a single crown prosthesis (without support of implants) placed in dental model casts, gray value differences for ROIs 1–9 were below 12% and gray value differences for ROIs 13–18 away from prostheses were below 10%. We found the gray value differences set to be between 7% and 8% for regions next to a single implant‐supported titanium prosthesis, and between 46% and 59% for regions between double implant‐supported, nickel‐chromium alloys (Ni‐Cr) prostheses. Quantification of the effect of prostheses and scanning parameters on dental CBCT gray values was assessed. PACS numbers: 87.59.bd, 87.57Q PMID:26894354
Bressan, Eriberto; Lops, Diego; Tomasi, Cristiano; Ricci, Sara; Stocchero, Michele; Carniel, Emanuele Luigi
2014-07-01
Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses. The aim of this study was to investigate retentive performance and mechanical strength of a Morse taper conometric system used as implant-supported fixed dental prostheses retention. Experimental and finite element investigations were performed. Experimental tests were achieved on a specific abutment-coping system, accounting for both cemented and non-cemented situations. The results from the experimental activities were processed to identify the mechanical behavior of the coping-abutment interface. Finally, the achieved information was applied to develop reliable finite element models of different abutment-coping systems. The analyses were developed accounting for different geometrical conformations of the abutment-coping system, such as different taper angle. The results showed that activation process, occurred through a suitable insertion force, could provide retentive performances equal to a cemented system without compromising the mechanical functionality of the system. These findings suggest that Morse taper conometrical system can provide a fixed connection between implants and dental prostheses if proper insertion force is applied. Activation process does not compromise the mechanical functionality of the system. © IMechE 2014.
Duan, Yuanyuan; Chandran, Ravi; Cherry, Denise
The purpose of this study was to create three-dimensional composite models of quad zygomatic implant-supported maxillary prostheses with a variety of alveolar bone defects around implant sites, and to investigate the stress distribution in the surrounding bone using the finite element analysis (FEA) method. Three-dimensional models of titanium zygomatic implants, maxillary prostheses, and human skulls were created and assembled using Mimics based on microcomputed tomography and cone beam computed tomography images. A variety of additional bone defects were created at the locations of four zygomatic implants to simulate multiple clinical scenarios. The volume meshes were created and exported into FEA software. Material properties were assigned respectively for all the structures, and von Mises stress data were collected and plotted in the postprocessing module. The maximum stress in the surrounding bone was located in the crestal bone around zygomatic implants. The maximum stress in the prostheses was located at the angled area of the implant-abutment connection. The model with anterior defects had a higher peak stress value than the model with posterior defects. All the models with additional bone defects had higher maximum stress values than the control model without additional bone loss. Additional alveolar bone loss has a negative influence on the stress concentration in the surrounding bone of quad zygomatic implant-supported prostheses. More care should be taken if these additional bone defects are at the sites of anterior zygomatic implants.
Bacchiocchi, Danilo
2017-01-01
Purpose To present a new intraoral welding technique, which can be used to manufacture screw-retained, mandibular fixed full-arch prostheses. Methods Over a 4-year period, all patients with complete mandibular edentulism or irreparably compromised mandibular dentition, who will restore the masticatory function with a fixed mandibular prosthesis, were considered for inclusion in this study. The “Ball Welding Bar” (BWB) technique is characterised by smooth prosthetic cylinders, interconnected by means of titanium bars which are adjustable in terms of distance from ball terminals and are inserted in the rotating rings of the cylinders. All the components are welded and self-posing. Results Forty-two patients (18 males; 24 females; mean age 64.2 ± 6.7 years) were enrolled and 210 fixtures were inserted to support 42 mandibular screw-retained, fixed full-arch prostheses. After two years of loading, 2 fixtures were lost, for an implant survival rate of 97.7%. Five implants suffered from peri-implant mucositis and 3 implants for peri-implantitis. Three of the prostheses (3/42) required repair for fracture (7.1%): the prosthetic success was 92.9%. Conclusions The BWB technique seems to represent a reliable technique for the fabrication of screw-retained mandibular fixed full-arch prostheses. This study was registered in the ISRCTN register with number ISRCTN71229338. PMID:28835752
Cementless Hydroxyapatite Coated Hip Prostheses
Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda
2015-01-01
More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848
Elements of implant-supported rehabilitation planning in patients with bruxism.
Sarmento, Hugo Ramalho; Dantas, Raquel Venâncio Fernandes; Pereira-Cenci, Tatiana; Faot, Fernanda
2012-11-01
The rehabilitation of partial or completely edentulous patients with implant-supported prostheses has been widely used, achieving high success rates. However, many studies consider the presence of bruxism as a contraindication for this treatment modality. The purpose of this study was to revise the literature and identify risk factors in implant-supported rehabilitation planning in subjects with bruxism. Available literature was searched through Medline, with no time limit, including only studies in English. Topics discussed were etiology of bruxism and its implications on dental implants, biomechanical considerations regarding the overload on dental implants, and methods to prevent the occurrence of overloads in implant-supported prostheses. The rehabilitation of bruxers using implant-supported prostheses, using implants with adequate length and diameter, as well as proper positioning seems to be a reliable treatment, with reduced risks of failure. Bruxism control through the use of a nightguard by rigid occlusal stabilization appliance relieved in the region of implants is highly indicated. Although it is clear that implant-supported rehabilitation of patients with bruxism requires adequate planning and follow-up, well-designed randomized controlled trials are needed to provide reliable evidence on the long-term success of this treatment modality.
Safety of MRI with metallic middle ear implants.
Tohme, Souheil M; Karkas, Alexandre A; Romanos, Bassam H
2003-01-01
Investigation of the effects of magnetic resonance fields on commonly used metallic middle ear implants. Nine middle ear prostheses (seven containing stainless steel and two made of pure gold used as control) were tested in vitro and one stainless steel stapedectomy prosthesis was tested on a cadaveric temporal bone. Each metallic prosthesis was placed in an empty Petri dish and introduced into a 1.5-tesla (T) magnetic resonance imaging (MRI) unit. Most of the prostheses were then placed in a water-filled Petri dish and reintroduced into the MRI unit. Eventual in vitro displacement was assessed visually by two means. In situ testing was done by implanting a piston in a cadaveric temporal bone and performing MR sequences ; any possible displacement was then assessed by CT scan and under microscopic vision. None of the prostheses was displaced in the empty Petri dish. However, while in the water-filled Petri dish, three of these moved with the flux. The implanted piston in the temporal bone did not move. The displacement of three of the prostheses in water is not relevant in real clinical situations. MRI can thus be considered safe in usual clinical settings, as far as our studied implants are concerned.
Danino, A; Rocher, F; Blanchet-Bardon, C; Revol, M; Servant, J M
2001-02-01
The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.
Gøthesen, Øystein; Slover, James; Havelin, Leif; Askildsen, Jan Erik; Malchau, Henrik; Furnes, Ove
2013-07-06
The use of Computer Assisted Surgery (CAS) for knee replacements is intended to improve the alignment of knee prostheses in order to reduce the number of revision operations. Is the cost effectiveness of computer assisted surgery influenced by patient volume and age? By employing a Markov model, we analysed the cost effectiveness of computer assisted surgery versus conventional arthroplasty with respect to implant survival and operation volume in two theoretical Norwegian age cohorts. We obtained mortality and hospital cost data over a 20-year period from Norwegian registers. We presumed that the cost of an intervention would need to be below NOK 500,000 per QALY (Quality Adjusted Life Year) gained, to be considered cost effective. The added cost of computer assisted surgery, provided this has no impact on implant survival, is NOK 1037 and NOK 1414 respectively for 60 and 75-year-olds per quality-adjusted life year at a volume of 25 prostheses per year, and NOK 128 and NOK 175 respectively at a volume of 250 prostheses per year. Sensitivity analyses showed that the 10-year implant survival in cohort 1 needs to rise from 89.8% to 90.6% at 25 prostheses per year, and from 89.8 to 89.9% at 250 prostheses per year for computer assisted surgery to be considered cost effective. In cohort 2, the required improvement is a rise from 95.1% to 95.4% at 25 prostheses per year, and from 95.10% to 95.14% at 250 prostheses per year. The cost of using computer navigation for total knee replacements may be acceptable for 60-year-old as well as 75-year-old patients if the technique increases the implant survival rate just marginally, and the department has a high operation volume. A low volume department might not achieve cost-effectiveness unless computer navigation has a more significant impact on implant survival, thus may defer the investments until such data are available.
NASA Astrophysics Data System (ADS)
Rubino, Caroline
Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper points were used to sample the peri-implant sulcus bacteria. All samples were then submitted to DNA purification, polymerase chain reaction (PCR), and sequencing protocols to assess relative numbers of bacterial species. Periodontal parameters were collected at both time points. Overall, our findings support several conclusions. Different implant abutment channel occluding materials appear to have no effect on the amount of observed microleakage and the peri-implant microbiome. Evidence for microleakage was found in the present study, corroborating existing in vivo evidence. Finally, we gained several insights regarding the peri implant microbiome. Of note, the peri-implant microbiome is well described by the classical periodontal microbial complexes, but a large portion consists of bacteria not previously classified into the microbial complexes.
Sukotjo, Cortino
2013-01-01
Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387
Prostheses for stapes surgery.
Slattery, W H; House, J W
1995-04-01
A variety of different implants are available today for use by the otologic surgeon. All prostheses are well tolerated, and the risks of complication as a result of their implantation are comparable. The most commonly used prostheses are the wire-Teflon piston and the stainless steel bucket handle. Although the otologic surgeon has a wide variety of prostheses to choose from, most have a preference for one particular type. Results of hearing improvement following a successful stapedectomy is more a function of the surgeon's experience than of the type of prosthesis used. As James L. Sheehy, MD, so often says, "if a technique is working well for you, don't change for change's sake" (personal communication, 1994).
Stress analysis in oral obturator prostheses, part II: photoelastic imaging
NASA Astrophysics Data System (ADS)
Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline
2014-06-01
In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.
Dai, Wen-yong; Zhou, Guo-xing; Zhang, Xiao-zhen; Zhao, Yi; Wang, Jie; Yang, Yi; Zhu, Zhi-jun; Tang, Chun-bo
2014-08-01
To offer individualized restorative strategies for patients receiving dental implants in the anterior esthetic zone but with inappropriate available conditions and evaluate the clinical outcomes. Forty-six patients with 58 implants were recruited for the study in accordance with the criteria and received individualized implant prostheses in the anterior esthetic zone. The patients were followed up for 3-24 months, and the clinical outcomes were evaluated by pink and white esthetic scores (PES/WES). The patients were from 18 to 69 years old, and followed up for 12.6 months in average. According to the third month follow-up esthetic scores, for PES, 1.72% of the patients got low scores, 44.83% got medium scores and 53.45% got high scores; For WES, 0% got low scores, 20.69% got medium scores and 79.31% got high scores. No implant failure or peri-implantitis occurred. Individualized restorative designs for implants in the esthetic zone can effectively improve the appearance of the prostheses which originally have no appropriate available space. Close follow-up and monitoring of the peri-implant soft tissue and proper oral hygiene instructions are important to ensure the conditions of the prostheses.
Economic Evaluation of Implant-Supported Overdentures in Edentulous Patients: A Systematic Review.
Zhang, Qi; Jin, Xin; Yu, Mengliu; Ou, Guoming; Matsui, Hiroyuki; Liang, Xing; Sasaki, Keiichi
Edentulous patients benefit significantly from implant-supported overdenture prostheses. The purpose of this systematic review was to evaluate the cost-effectiveness of implant-supported overdentures (IODs) for edentulous patients. The search was limited to studies written in English and included an electronic and manual search through MEDLINE (Ovid, 1946 to November 2015), Embase (Ovid, 1966 to November 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (to November 2015), and PubMed (to November 2015). Two investigators extracted the data and assessed the studies independently. No meta-analysis was conducted due to the high heterogeneity within the literature. Of the initial 583 selected articles, 10 studies involving 802 participants were included. Of these, 6 studies had a high risk of bias and the rest had an unclear risk of bias. Implant-supported prostheses were more cost-effective when compared to conventional dentures and fixed implant-supported prostheses. Overdentures supported by two implants and magnet attachment were reported as cost-effective. Implant-supported overdentures are a cost-effective treatment for edentulous patients. More clinical studies with appropriate scientific vigor are required to further assess the cost-effectiveness of implant-supported overdentures.
Koller, Beatrice; Att, Wael; Strub, Jorg-Rudolf
2011-01-01
The aim of this systematic literature review was to investigate the survival rates of teeth, implants, and double crown-retained removable dental prostheses (RDPs). A systematic review of the literature published from January 1973 through May 2010 was conducted using electronic databases and hand-searching to assess the clinical outcomes of teeth, implants, and double crown-retained RDPs. This review yielded 512 articles, which were narrowed down to 11. The included studies demonstrated tooth survival rates between 60.6% and 95.3% after an observation period of 4 to 10 years. The survival rates of RDPs supported by teeth ranged between 90.0% and 95.1% after 4 and 5.3 years, respectively. The survival rates of implants supporting prostheses in the mandible were between 97% and 100% after an observation period between 3 and 10.4 years. The survival rates of implant-retained RDPs in the mandible ranged between 95% and 100% after 9 and 10.4 years. Teeth and implants supporting prostheses in the maxilla, as well as the RDPs themselves, demonstrated a survival rate of 100% after 3.2 years. The current literature does not provide sufficient information regarding the long-term outcome of double crown-retained RDPs. Further studies based on a higher level of evidence are needed to validate the outcomes of this treatment modality.
Ahmed, Ayman; Maroulakos, Georgios; Garaicoa, Jorge
2016-05-01
Abutment screw loosening represents a common and challenging technical complication of cement-retained implant prostheses. This article describes the fabrication of a simple and accurate poly(methyl methacrylate) guide for identifying the location and angulation of the abutment screw access channel of a cement-retained implant prosthesis with a loosened abutment screw. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Jacobs, R; Bou Serhal, C; van Steenberghe, D
1997-06-01
A stereognostic ability test was performed in 60 patients. Forty patients were rehabilitated by means of osseointegrated implants. One group consisted of 20 patients with fixed prostheses on implants in both the upper and lower jaws. The other 20 patients had a maxillary denture while in the mandible an overdenture was retained by means of two implants connected by a bar. They were compared to a group of 20 subjects (controls) with a non-restored natural dentition. For the stereognostic ability test, subjects had to recognise ten different test pieces by manipulating them with two antagonistic incisor teeth, avoiding any contact with other oral structures. Both response time and percentage accuracy of recognition were evaluated. The present findings indicated that subjects with an overdenture on implants did not score significantly different from those with an implant-supported fixed prosthesis. In contrast, subjects with teeth had a significantly better stereognostic ability. The percentage of correct responses was 52% for overdentures, 56% for fixed prostheses on implants and 75% for natural dentitions. From these results, it could be concluded that the stereognostic ability is impaired in subjects rehabilitated with osseointegrated implants by about one-third to one-quarter compared to subjects with natural teeth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewanjee, M.K.; Fuster, V.; Rao, S.A.
1983-05-01
A noninvasive technique has been developed in the dog model for imaging, with a gamma camera, the platelet deposition on Bjoerk-Shiley mitral valve prostheses early postoperatively. At 25 hours after implantation of the prosthesis and 24 hours after intravenous administration of 400 to 500 microCi of platelets labeled with indium-111, the platelet deposition in the sewing ring and perivalvular cardiac tissue can be clearly delineated in a scintiphotograph. An in vitro technique was also developed for quantitation of visceral microemboli in brain, lungs, kidneys, and other tissues. Biodistribution of the labeled platelets was quantitated, and the tissue/blood radioactivity ratio wasmore » determined in 22 dogs in four groups: unoperated normal dogs, sham-operated dogs, prosthesis-implanted dogs, and prosthesis-implanted dogs treated with dipyridamole before and aspirin and dipyridamole immediately after operation. Fifteen to 20% of total platelets were consumed as a consequence of the surgical procedure. On quantitation, we found that platelet deposition on the components of the prostheses was significantly reduced in prosthesis-implanted animals treated with dipyridamole and aspirin when compared with prosthesis-implanted, untreated dogs. All prosthesis-implanted animals considered together had a twofold to fourfold increase in tissue/blood radioactivity ratio in comparison with unoperated and sham-operated animals, an indication that the viscera work as filters and trap platelet microemboli that are presumably produced in the region of the mitral valve prostheses. In the dog model, indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of platelet deposition on mechanical mitral valve prostheses, in vitro evaluation of platelet microembolism in viscera, in vitro quantitation of surgical consumption of platelets, and evaluation of platelet-inhibitor drugs.« less
NASA Astrophysics Data System (ADS)
Sgambitterra, Emanuele; Piccininni, Antonio; Guglielmi, Pasquale; Ambrogio, Giuseppina; Fragomeni, Gionata; Villa, Tomaso; Palumbo, Gianfranco
2018-05-01
Cranial implants are custom prostheses characterized by quite high geometrical complexity and small thickness; at the same time aesthetic and mechanical requirements have to be met. Titanium alloys are largely adopted for such prostheses, as they can be processed via different manufacturing technologies. In the present work cranial prostheses have been manufactured by Super Plastic Forming (SPF) and Single Point Incremental Forming (SPIF). In order to assess the mechanical performance of the cranial prostheses, drop tests under different load conditions were conducted on flat samples to investigate the effect of the blank thickness. Numerical simulations were also run for comparison purposes. The mechanical performance of the cranial implants manufactured by SPF and SPIF could be predicted using drop test data and information about the thickness evolution of the formed parts: the SPIFed prosthesis revealed to have a lower maximum deflection and a higher maximum force, while the SPFed prostheses showed a lower absorbed energy.
Samaniego Alonso, R; Gaviria Parada, E; Pons Cabrafiga, M; Espallargues Carreras, M; Martinez Cruz, O
2018-02-28
In our environment, it is increasingly necessary to perform an activity based on scientific evidence and the field of prosthetic surgery should be governed by the same principles. The national arthroplasty registries allow us to obtain a large amount of data in order to evaluate this technique. The aim of our study is to analyse the scientific evidence that supports the primary total knee arthroplasties implanted in Catalonian public hospitals, based on the Arthoplasty Registry of Catalonia (RACat) MATERIAL AND METHODS: A review of the literature was carried out on knee prostheses (cruciate retaining, posterior stabilized, constricted and rotational) recorded in RACat between the period 2005-2013 in the following databases: Orthopedic Data Evaluation Panel, PubMed, TripDatabase and Google Scholar. The prostheses implanted in fewer than 10 units (1,358 prostheses corresponding to 62 models) were excluded. 41,947 prostheses (96.86%) were analysed out of 43,305 implanted, corresponding to 74 different models. In 13 models (n = 4,715) (11.24%) no clinical evidence to support their use was found. In the remaining 36 models (n = 13,609) (32.45%), level iv studies were the most predominant evidence. There was a significant number of implanted prostheses (11.24%) for which no clinical evidence was found. The number of models should be noted, 36 out of 110, with fewer than 10 units implanted. The use of arthroplasty registries has proved an extremely useful tool that allows us to analyse and draw conclusions in order to improve the efficiency of this surgical technique. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Immediate loading with fixed full-arch prostheses in the maxilla: Review of the literature
Peñarrocha-Oltra, David; Covani, Ugo; Peñarrocha-Diago, Miguel
2014-01-01
Objectives: To critically review the evidence-based literature on immediate loading of implants with fixed full-arch prostheses in the maxilla to determine 1) currently recommended performance criteria and 2) the outcomes that can be expected with this procedure. Study Desing: Studies from 2001 to 2011 on immediate loading with fixed full-arch maxillary prostheses were reviewed. Clinical series with at least 5 patients and 12 months of follow-up were included. Case reports, studies with missing data and repeatedly published studies were excluded. In each study the following was assessed: type of study, implant type, number of patients, number of implants, number of implants per patient, use of post-extraction implants, minimum implant length and diameter, type of prosthesis, time until loading, implant survival rate, prosthesis survival rate, marginal bone loss, complications andmean follow-up time. Criteria for patient selection, implant primary stability and bone regeneration were also studied. Results: Thirteen studies were included, reporting a total of 2484 immediately loaded implants in 365 patients. Currently accepted performance criteria regarding patient and implant selection, and surgical and prosthetic procedures were deduced from the reviewed articles. Implant survival rates went from 87.5% to 100%, prosthesis survival rates from 93.8% to 100% and radiographic marginal bone loss from 0.8 mm to 1.6 mm.No intraoperative complications and only minor prosthetic complications were reported. Conclusions: The literature on immediate loading with fixed full-arch prostheses in the maxilla shows that a successful outcome can be expected if adequate criteria are used to evaluate the patient, choose the implant and perform the surgical and prosthetic treatment. Lack of homogeneity within studies limits the relevance of the conclusions that can be drawn, and more controlled randomized studies are necessary to enable comparison between the immediate and the conventional loading procedures. Key words:Immediate loading, full-arch, dental implants, loading protocols. PMID:24880445
Further studies on the effects of magnetic resonance imaging fields on middle ear implants.
Applebaum, E L; Valvassori, G E
1990-10-01
We investigated the effects of magnetic resonance imaging (MRI) fields on 21 stapedectomy prostheses and other middle ear implants and two different receiver-stimulator modules from 22-channel cochlear implants. None of the middle ear implants was displaced by the magnetic field, except for one platinum-stainless steel stapedectomy piston. Magnetism was not induced in any of the middle ear implants subjected to prolonged exposure in the MRI scanner. We conclude that MRI could pose a hazard to patients who have had stapedectomy using certain platinum-stainless steel piston prostheses and to patients with cochlear implants. Magnetic resonance imaging should pose no hazard to patients who have had the other middle ear implants reported on in this and our previous investigation.
Schwager, K
1998-01-01
The middle ear poses unique challenges when finding suitable materials for ossicular reconstruction, primarily because of its link to the external environment via the eustachian tube and, hence, its greater exposure to infectious agents. In this study, the biocompatability of titanium was examined in the middle ear of rabbits by using light and scanning electron microscopy. Implants were placed as middle ear prostheses or as free implants. These were inspected at 28 days, 84 days, 168 days, 336 days and 504 days following implantation for mucosal coverage, percent epithelization and any sign of foreign-body reaction. After 28 days, the prostheses were covered by regular mucosa. Although a majority of the free implants took up to 336 days for complete epithelialization, some of the free implants were not epithelialized even at day 504. There were no inflammatory cells observed on the surface of the material, nor were unusual amounts of fibrous tissue seen. In addition, the titanium material exhibited an affinity toward bone. The results of this animal experiment indicate that titanium is a favorable material for ossicular replacement prostheses.
Akay, Canan; Yaluğ, Suat
2015-01-01
Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086
A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.
Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti
2014-02-01
Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.
Kroeplin, Birgit S; Strub, Joerg R
2011-01-01
The aim of this study was to describe the didactic and clinical undergraduate implant dentistry program of the Albert-Ludwigs University, Freiburg, Germany, with emphasis on the clinical implant experience. A detailed description of the implant curriculum at Albert-Ludwigs University is given with documented exemplary cases and additional flow charts. All students participate in 28 hours of lectures and approximately 64 hours of seminars with hands-on courses and gain clinical experience. All undergraduate students are eligible to place and restore oral implants. Emphasis is placed on prosthetic-driven planning of implant positions, three-dimensional imaging, and computer-guided implant placement. Implant restorations performed by undergraduate students comprise single crowns and small multiunit fixed dental prostheses in partially edentulous posterior maxillae and anterior or posterior mandibles, implant-retained overdentures (snap attachment) in edentulous patients, and telescopic fixed-removable dental prostheses on remaining teeth and strategically placed additional implants. Over the past 2.5 years, 51 patients were treated with 97 dental implants placed by students in the undergraduate program. Seventy-one restorations were inserted: 60.6% single crowns, 7% fixed dental protheses, 21.1% overdentures, and 11.3% telescopic fixed-removable dental prostheses. The implant survival rate was 98.9%. Because survival rates for dental implants placed and restored by students are comparable to those of experienced dentists, oral implant dentistry should be implemented as part of the undergraduate dental curriculum.
Pjetursson, Bjarni E; Asgeirsson, Asgeir G; Zwahlen, Marcel; Sailer, Irena
2014-01-01
The objective of this systematic review was to assess and compare the survival and complication rates of implant-supported prostheses reported in studies published in the year 2000 and before, to those reported in studies published after the year 2000. Three electronic searches complemented by manual searching were conducted to identify 139 prospective and retrospective studies on implant-supported prostheses. The included studies were divided in two groups: a group of 31 older studies published in the year 2000 or before, and a group of 108 newer studies published after the year 2000. Survival and complication rates were calculated using Poisson regression models, and multivariable robust Poisson regression was used to formally compare the outcomes of older and newer studies. The 5-year survival rate of implant-supported prostheses was significantly increased in newer studies compared with older studies. The overall survival rate increased from 93.5% to 97.1%. The survival rate for cemented prostheses increased from 95.2% to 97.9%; for screw-retained reconstruction, from 77.6% to 96.8%; for implant-supported single crowns, from 92.6% to 97.2%; and for implant-supported fixed dental prostheses (FDPs), from 93.5% to 96.4%. The incidence of esthetic complications decreased in more recent studies compared with older ones, but the incidence of biologic complications was similar. The results for technical complications were inconsistent. There was a significant reduction in abutment or screw loosening by implant-supported FDPs. On the other hand, the total number of technical complications and the incidence of fracture of the veneering material was significantly increased in the newer studies. To explain the increased rate of complications, minor complications are probably reported in more detail in the newer publications. The results of the present systematic review demonstrated a positive learning curve in implant dentistry, represented in higher survival rates and lower complication rates reported in more recent clinical studies. The incidence of esthetic, biologic, and technical complications, however, is still high. Hence, it is important to identify these complications and their etiology to make implant treatment even more predictable in the future.
Safety of magnetic resonance imaging of stapes prostheses.
Syms, Mark James
2005-03-01
Assess the safety of performing magnetic resonance imaging (MRI) on patients with stapes prostheses. Survey and animal model. A survey regarding implant usage, MRI procedures, and adverse outcomes after MRI in patients previously undergoing stapes procedures. Guinea pigs implanted with ferromagnetic 17 to 4 stainless steel, 316L nonferromagnetic stainless steel, titanium, and fluoroplastic stapes prostheses underwent a MRI in a 4.7 Tesla MR system. : Three adverse outcomes were reported on the clinical survey. One adverse event occurred during an MRI performed on a recalled ferromagnetic prosthesis. The other two adverse events were probably not secondary to MRI exposure. No damage or inflammation was observed in the region of the oval window or vestibule of implanted guinea pigs exposed to a 4.7 Tesla MR system. The combination of prior studies, the clinical survey, and the absence of histopathologic evidence of damage in the guinea pigs is compelling evidence that MRI for patients with stapes prostheses is safe. Implanting physicians should feel comfortable clearing a patient for a MRI in a 1.5 Tesla or 3.0 Tesla MRI. It is imperative for the physician to qualify the field strength when clearing a patient to undergo a MRI.
Fabrication of a new silicone auricular prosthesis without removing the existing metallic framework.
Goveas, Reiyal; Shrestha, Binit; Srithavaj, M L Theerathavaj; Thaworanunta, Sita
2014-12-01
Silicone prostheses require constant repair and refabrication. Auricular prostheses retained with implants have better retention than adhesive-retained prostheses. However, refabrication is complicated if the patient is unwilling to surrender the metallic framework attached to the implants and revert to the use of adhesives. This article describes a technique by which the metal framework of the existing prosthesis need not be removed, thereby improving the patient's quality of life until the new prosthesis is delivered. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Guzmán-Venegas, Rodrigo A; Palma, Felipe H; Biotti P, Jorge L; de la Rosa, Francisco J Berral
2018-06-01
To compare the frequency or spectral components between different regions of the superficial masseter in young natural dentate and total edentulous older adults rehabilitated with removable prostheses and fixed-implant support. A secondary objective was to compare these components between the three groups. 21 young natural dentate and 28 edentulous (14 with removable prostheses and 14 with fixed-implant support) were assessed. High-density surface electromyography (sEMG) was recorded in four portions of the superficial masseter during submaximal isometric bites. Spectral components were obtained through a spectral analysis of the sEMG signals. An analysis of mixed models was used to compare the spectral components. In all groups, the spectral components of the anterior portion were lower than in the posterior region (p < 0.05). Both edentulous groups showed lower spectral components and median frequency slope than the natural dentate group (p < 0.05). The removable prostheses group showed the greatest differences with natural dentate group. There were significant differences in the spectral components recorded in the different regions of the superficial masseter. The lower spectral components and fatigability of older adults rehabilitated with prostheses could be a cause of a greater loss of type II fibers, especially in the removable prostheses group. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain.
Terrier, Alexandre; Fernandes, Caroline Sieger; Guillemin, Maïka; Crevoisier, Xavier
2017-10-01
Total ankle replacement is associated to a high revision rate. To improve implant survival, the potential advantage of prostheses with fixed bearing compared to mobile bearing is unclear. The objective of this study was to test the hypothesis that fixed and mobile bearing prostheses are associated with different biomechanical quantities typically associated to implant failure. With a validated finite element model, we compared three cases: a prosthesis with a fixed bearing, a prosthesis with a mobile bearing in a centered position, and a prosthesis with mobile bearing in an eccentric position. Both prostheses were obtained from the same manufacturer. They were tested on seven tibias with maximum axial compression force during walking. We tested the hypothesis that there was a difference of bone strain, bone-implant interfacial stress, and bone support between the three cases. We also evaluated, for the three cases, the correlations between bone support, bone strain and bone-implant interfacial stress. There were no statistically significant differences between the three cases. Overall, bone support was mainly trabecular, and less effective in the posterior side. Bone strain and bone-implant interfacial stress were strongly correlated to bone support. Even if slight differences are observed between fixed and mobile bearing, it is not enough to put forward the superiority of one of these implants regarding their reaction to axial compression. When associated to the published clinical results, our study provides no argument to warn surgeons against the use of two-components fixed bearing implants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Trabandt, Nicolaus; Brandes, Gudrun; Wintermantel, Erich; Lenarz, Thomas; Stieve, Martin
2004-09-01
Because the performance of titanium dioxide (TiO2) has not yet been assessed in the unique environment of the middle ear, its role as an ossicular replacement prototype in the form of a total ossicular replacement prosthesis (TORP) was tested and compared with aluminum oxide (Al2O3), once considered to be a suitable implant material. Ossiculoplasty was performed by implanting TORPs into the tympanic cavities of rabbits. After an implantation period of 28, 84, or 300 days, the petrous bones were extracted, whereby the biocompatibility of the prostheses was examined using light microscopy and scanning electron microscopy to determine morphologic changes in situ. Proper implant placement and functionality was tested via manual manipulation. Mucosa was seen covering most of the implants by day 84. Inflammatory cells were not observed in any of the specimens examined. The macroporous TiO2 TORPs were subjected to osseous infiltration, material dissolution, and fragmentation, whereas the microporous TiO2 implants were subjected to an increasing frequency of fissure formations. The Al2O3 prostheses demonstrated signs of material dissolution by producing encapsulated aggregates during the experimental trial period. Neither the macroporous nor microporous oxide ceramics were able to withstand the oscillatory stress to which they were continually subjected. Although porosity allows for the rapid integration of an implant material into a biological environment, its properties are not suited to fulfill the requirements of strength and long-term stability, which are demanded of middle ear prostheses.
Yunus, Norsiah; Masood, Mohd; Saub, Roslan; Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Thomason, John Mark
2016-07-01
To assess the oral health-related quality of life (OHRQoL) of patients provided with mandibular implant fixed partial prostheses (IFPP) for rehabilitation of two adjacent missing posterior teeth and complete denture patients provided with mandibular implant-supported overdenture (ISOD). The response to change in OHRQoL with implant prostheses was additionally compared. In this prospective study, 20 IFPP (mean age 47.0; SD 12.9 years) and 28 ISOD (mean age 61.5; SD 9.1 years) patients received 2 mandibular implants. Metal ceramic nonsplinted fixed prostheses were provided in IFPP group, while in ISOD group, the mandibular overdentures were retained by nonsplinted attachments. Patients rated their oral health-related quality of life using OHIP-14 Malaysian version at baseline (T0), 2-3 months (T1) and 1 year (T2) postimplant treatment. Mean OHIP-14 for total and domain scores between groups and intervals was analysed using repeated-measures ANOVA and t-test. Mann-Whitney and Wilcoxon signed-rank tests were used for the comparison of mean score change and effect size, while the association between pre- and post-treatment scores was determined using multivariate linear regression modelling. The total OHIP and domain scores before implant treatment were significantly higher (lower OHRQoL) in IFPP than in ISOD groups, except for physical pain where this domain showed similar impact in both groups. Postimplant scores between groups at T1 and T2 showed no significant difference. The mean score changes at T0-T1 and T0-T2 for total OHIP-14 and domains were significantly greater in IFPP except in the domains of physical pain and disability which showed no difference. Large effect size (ES) was observed for total OHIP-14 in IFPP while moderate in ISOD. Improved OHRQoL was dependent on the treatment group and pretreatment score. Improvement in OHRQoL occurred following both mandibular implant-supported overdentures and implant fixed partial prostheses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Stieglitz, T; Schuettler, M; Koch, K P
2004-04-01
Neural prostheses partially restore body functions by technical nerve excitation after trauma or neurological diseases. External devices and implants have been developed since the early 1960s for many applications. Several systems have reached nowadays clinical practice: Cochlea implants help the deaf to hear, micturition is induced by bladder stimulators in paralyzed persons and deep brain stimulation helps patients with Parkinson's disease to participate in daily life again. So far, clinical neural prostheses are fabricated with means of precision mechanics. Since microsystem technology opens the opportunity to design and develop complex systems with a high number of electrodes to interface with the nervous systems, the opportunity for selective stimulation and complex implant scenarios seems to be feasible in the near future. The potentials and limitations with regard to biomedical microdevices are introduced and discussed in this paper. Target specifications are derived from existing implants and are discussed on selected applications that has been investigated in experimental research: a micromachined implant to interface a nerve stump with a sieve electrode, cuff electrodes with integrated electronics, and an epiretinal vision prosthesis.
Allen, Finbarr; McMillan, Anne
2002-06-01
The loss of natural teeth compromises chewing efficiency, and edentulous patients often have a diet that is deficient in fibre and vitamins. Prostheses that are retained on implants offer the possibility of overcoming some of the limitations of conventional dentures in terms of chewing efficiency. The aim of this study was to test the hypothesis that improvement in satisfaction with oral prostheses would result in improved food selection in edentulous patients. This prospective study involved three groups, namely (i) subjects who requested and received implants to stabilise a complete fixed or removable prosthesis (IG, n = 26), (ii) edentulous subjects who requested implant prostheses, but received conventional dentures (CDG1, n = 22), and (iii) edentulous subjects who requested and received conventional dentures (CDG2, n = 35). Data were collected using validated questionnaires pre- and postoperatively. Prior to treatment, all subjects were asked whether they ate a variety of hard and soft foods, to indicate the degree of difficulty they experienced when chewing these foods, and to rate their satisfaction with various aspects of their maxillary and mandibular complete dentures. Following the completion of treatment, subjects completed the questionnaires again. Pre- and postoperative data were compared. Subjects who received implant prostheses reported significant improvement in chewing hard and soft foods. CDG2 subjects also reported improvement, but CDG1 subjects reported no change or even deterioration following treatment. Despite reported improvement in satisfaction with comfort and ability to chew food, 30-50% of IG and CDG2 subjects still avoided eating foods such as carrot and apple. This suggests that, in the absence of tailored dietary advice, apparently successful prosthetic rehabilitation does not necessarily result in a satisfactory diet.
Gonçalves, Fernanda de Cássia Papaiz; Amaral, Marina; Borges, Alexandre Luiz Souto; Gonçalves, Luiz Fernando Martins; Paes-Junior, Tarcisio José de Arruda
2018-04-01
Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Ortorp, A; Linden, B; Jemt, T
1999-01-01
The purpose of this study was to report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks and to compare their performance with that of prostheses provided with conventional cast frameworks. On a routine basis, a consecutive group of 824 edentulous patients were provided with fixed prostheses supported by implants in the edentulous mandible. In addition to conventional gold-alloy castings, patients were at random provided with 2 kinds of laser-welded titanium frameworks. In all, 155 patients were included in the 2 titanium framework groups. A control group of 53 randomly selected patients with conventional gold-alloy castings was used for comparison. Clinical and radiographic 5-year data was collected for the 3 groups. All followed patients still had fixed prostheses in the mandible after 5 years. The overall cumulative success rates were 95.9% and 99.7% for titanium-framework prostheses and implants, respectively. The corresponding success rates for the control group were 100% and 99.6%, respectively. Bone loss was 0.5 mm on average during the 5-year follow-up period. The most common complications for titanium frameworks were resin or tooth fractures, gingival inflammation, and fractures of the metal frames (10%). One of the cast frameworks fractured and was resoldered. Loose and fractured implant screw components were few (< 1%). Even though the cast frameworks had a higher success rate, the overall titanium framework treatment result was well in accordance with the result of the control group. The test groups performed better after clinicians had gained some experience with the technique, and laser-welded titanium frameworks seem to be a viable alternative to conventional castings in the edentulous mandible.
Ion beam sputter modification of the surface morphology of biological implants
NASA Technical Reports Server (NTRS)
Weigand, A. J.; Banks, B. A.
1976-01-01
The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion beam sputtered surfaces.
Ion-beam-sputter modification of the surface morphology of biological implants
NASA Technical Reports Server (NTRS)
Weigand, A. J.; Banks, B. A.
1977-01-01
The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion-beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron-bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion-beam-sputtered surfaces.
Wireless radio channel for intramuscular electrode implants in the control of upper limb prostheses.
Stango, Antonietta; Yazdandoost, Kamya Yekeh; Farina, Dario
2015-01-01
In the last few years the use of implanted devices has been considered also in the field of myoelectric hand prostheses. Wireless implanted EMG (Electromyogram) sensors can improve the functioning of the prosthesis, providing information without the disadvantage of the wires, and the usability by amputees. The solutions proposed in the literature are based on proprietary communication protocols between the implanted devices and the prosthesis controller, using frequency bands that are already assigned to other purposes. This study proposes the use of a standard communication protocol (IEEE 802.15.6), specific for wireless body area networks (WBANs), which assign a specific bandwidth to implanted devices. The propagation losses from in-to-on body were investigated by numerical simulation with a 3D human model and an electromagnetic solver. The channel model resulting from the study represents the first step towards the development of myoelectric prosthetic hands which are driven by signals acquired by implanted sensors. However these results can provide important information to researchers for further developments, and manufacturers, which can decrease the production costs for hand prostheses having a common standard of communication with assigned frequencies of operation.
Retrospective cohort study of the clinical performance of 1-stage dental implants.
Carr, Alan B; Choi, Yong-Geun; Eckert, Steven E; Desjardins, Ronald P
2003-01-01
To evaluate long-term clinical performance of 1-stage dental implant prostheses at a single clinic, emphasizing clinical and demographic characteristics that affect implant survival. Dental records of all 308 patients (674 implants) treated with 1-stage implants at Mayo Clinic from October 1993 through May 2000 were reviewed from implant placement to last visit. Exposure and outcome variables affecting performance were collected separately to control bias in the data collection process. Additional confounding factors (age and sex) were adjusted with the stratified Cox proportional hazards model. Implant survival was determined by means of a Kaplan-Meier survival estimate. The log-rank test was used to determine the role of clinical and demographic variables in implant survival. The relative risk associated with the possible effect of clinical and demographic variables on implant survival was estimated with the Cox proportional hazards model. The implant survival rate (n = 654 implants) was 97% (mean +/- SD follow-up, 21.0 +/- 18.8 months; range, 1 to 78 months). Performance bias was limited because nearly all patients were treated by 1 prosthodontist. Two implants failed after loading (6 and 9 months). The incidence of complications was less than 4%. Among the implant failures, use of heterogeneous bone graft was associated with 4.8 times more failures than was use of autogenous bone graft (P = .04). After augmentation, delaying implant placement for 5 to 6 months resulted in 8.6 times more failures than the rate after earlier placement (P < .001). Retrospective review of the clinical performance of a 1-stage dental implant system yielded a 97% survival rate, with no failures noted after 13 months. Prosthetic complications were low, especially for fixed implant prostheses. Clinical performance of 1-stage dental implant prostheses between 1993 and 2000 demonstrated a high level of predictability.
Processing of hydroxylapatite coatings on titanium alloy bone prostheses
Nastasi, M.A.; Levine, T.E.; Mayer, J.W.; Pizziconi, V.B.
1998-10-06
Processing of hydroxylapatite sol-gel films on titanium alloy bone prostheses. A method utilizing non-line-of-sight ion beam implantation and/or rapid thermal processing to provide improved bonding of layers of hydroxylapatite to titanium alloy substrates while encouraging bone ingrowth into the hydroxylapatite layers located away from the substrate, is described for the fabrication of prostheses. The first layer of hydroxylapatite is mixed into the substrate by the ions or rapidly thermally annealed, while subsequent layers are heat treated or densified using ion implantation to form layers of decreasing density and larger crystallization, with the outermost layers being suitable for bone ingrowth.
Processing of hydroxylapatite coatings on titanium alloy bone prostheses
Nastasi, Michael A.; Levine, Timothy E.; Mayer, James W.; Pizziconi, Vincent B.
1998-01-01
Processing of hydroxylapatite sol-gel films on titanium alloy bone prostheses. A method utilizing non-line-of-sight ion beam implantation and/or rapid thermal processing to provide improved bonding of layers of hydroxylapatite to titanium alloy substrates while encouraging bone ingrowth into the hydroxylapatite layers located away from the substrate, is described for the fabrication of prostheses. The first layer of hydroxylapatite is mixed into the substrate by the ions or rapidly thermally annealed, while subsequent layers are heat treated or densified using ion implantation to form layers of decreasing density and larger crystallization, with the outermost layers being suitable for bone ingrowth.
Batista, Mauro; Bonachela, Wellington; Soares, Janir
2008-06-01
The extraction of teeth involves the elimination of extremely sensitive periodontal mechanoreceptors, which play an important role in oral sensory perception. The aim of this study was to evaluate the recovery of interocclusal sensory perception for micro-thickness in individuals with different types of implant-supported prostheses. Wearers of complete dentures (CDs) comprised the negative control group (group A, n=17). The experimental group consisted of wearers of prostheses supported by osseointegrated implants (Group B, n=29), which was subsequently divided into 4 subgroups: B(1) (n=5)--implant supported overdentures (ISO) occluding with CD; B(2) (n=6)--implant-supported fixed prostheses (ISFP) occluding with CD; B(3) (n=8)--wearers of maxillary and mandibular ISFP, and B(4) (n=10)--ISFP occluding with natural dentition (ND). Individuals with ND represented the positive control group (Group C, n=24). Aluminum foils measuring 10 microm, 24 microm, 30 microm, 50 microm, 80 microm, and 104 microm thickness were placed within the premolar area, adding up to 120 tests for each individual. The mean tactile thresholds of groups A, B1, B2, B3, B4, and C were 92 microm, 27 microm, 27 microm, 14 microm, 10 microm, and 10 microm, respectively. [Correction added after publication online 18 April 2008: in the preceding sentence 92 microm, 27 microm, 14 microm, 10 microm and 10 microm, was corrected to 92 microm, 27 microm, 27 microm, 14 microm, 10 microm and 10 microm]. The Kruskal-Wallis test revealed significant difference among groups (P<0.05). The Dunn test revealed that group A was statistically different from groups C, B(3), and B(4), and that B(1) and B(2) were statistically different from group C. Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses could be observed. Moreover, ISO and/or ISFP combinations may similarly maximize the recovery of osseoperception.
Wieners, G; Pech, M; Streitparth, F; Jansson, V; Plitz, W
2007-01-01
The aim of this study was the detection of areas at risk at the proximal femur after implantation of different femur neck prostheses using the photoelastic stress analysis. Twelve pairs of human femurs were used as examination material. The analysis of the stress pattern was done with a stepwise increasing load up to the quadruple of body weight before and after implantation of three models of femur neck prostheses which were implanted cementless. The "CUT" and "Cigar" models are coated with a tripod structure. The "Cigar" model has a lateral thrust plate. The lateral end of the "CUT" model is curved and this end is attached to the lateral corticalis. The third model, the "rip prosthesis" has two layers for rotational stability. Subsequently, the micromotions of the implanted prosthesis in the femural neck were examined with alternating weight loads (1000 +/- 700 N). The Cigar prosthesis showed the most changes of stress distribution because of the lateral thrust plate with concentration of isochromatic lines to the lateral boring. In the region of the oseotomy an increase of strain up 1440 microm/m could be detected for the Cigar and up to 1000 microm/m for the rib prosthesis. The stress pattern after implantation of the CUT prosthesis remained very similar apart from a slight increase of stress values (720 microm/m). Only for the Cigar prostheses were the measured micromotions below the critical value for a possible osteointegration with a mean value of 134 microm/m. The stress pattern after implantation of the CUT prosthesis remained most similar to the preinterventional stress distribution. Because of this, it is to be expected that the osseous modification would stay at a low level. The question of osteointegration can only be answered in long-term in-vivo studies.
R&D on dental implants breakage
NASA Astrophysics Data System (ADS)
Croitoru, Sorin Mihai; Popovici, Ion Alexandru
2017-09-01
Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.
Jemt, T; Henry, P; Lindén, B; Naert, I; Weber, H; Bergström, C
2000-01-01
The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.
Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S
1996-06-01
Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.
Borie, Eduardo; Leal, Eduardo; Orsi, Iara Augusta; Salamanca, Carlos; Dias, Fernando José; Weber, Benjamin
2018-01-01
The aim of this study was to analyze the influence of three different transmucosal heights of the abutments in single and multiple implant-supported prostheses through the finite element method. External hexagon implants, MicroUnit, and EsthetiCone abutments were scanned and placed in an edentulous maxillary model obtained from a tomography database. The simulations were divided into two groups: (1) one implant with 3.75 × 10 mm placed in the upper central incisor, simulating a single implant-supported fixed prosthesis with an EsthetiCone abutment; and (2) two implants with 3.75 × 10 mm placed in the upper lateral incisors with MicroUnit abutments, simulating a multiple implant-supported prosthesis. Subsequently, each group was subdivided into three models according to the transmucosal height (1, 2, and 3 mm). A static oblique load at an angle of 45 degrees to the long axis of the implant in palatal-buccal direction of 150 and 75 N was applied for multiple and single implant-supported prosthesis, respectively. The implants and abutments were assessed according to the equivalent Von Mises stress analyses while the bone and ceramics were analyzed through maximum and minimum principal stresses. The total deformation values increased in all models, while the transmucosal height was augmented. The transmucosal height of the abutments influences the stress values at the bone, ceramics, implants, and abutments of both the single and multiple implant-supported prostheses, with the transmucosal height of 1 mm showing the lowest stress values.
Krennmair, Gerald; Krainhöfner, Martin; Waldenberger, Otmar; Piehslinger, Eva
2007-01-01
The aim of this retrospective study was to present the results of implants and natural teeth used as combined abutments to support maxillary telescopic prostheses. Between 1997 and 2004, 22 patients with residual maxillary teeth underwent prosthodontic rehabilitation with supplementary implant placement of implant-tooth-supported telescopic prostheses. A total of 60 supplementary implants (mean: 2.9 implants; SD: 1.6; range: 1 to 5 per patient) were placed in strategic position and connected with 48 natural abutment teeth (mean: 2.2 teeth; SD: 0.9; range: 1 to 4 per patient) using telescopic crowns. The follow-up registration included implant and natural tooth survival rates and peri-implant and periodontal parameters, along with prosthodontic maintenance. Natural tooth abutments were additionally followed to compare their periodontal parameters at baseline to the follow-up examination. After a mean of 38 months (12 to 108 months) no implants or natural tooth abutments were lost (survival rate: 100%). There was no fracture, endodontic treatment, loss, or intrusion of natural teeth used for telescopic abutments. Implant abutments showed high stability and excellent periimplant soft tissue conditions. Natural tooth abutments used for double crowns also showed uneventful progress. A low rate of prosthodontic maintenance was seen, with implant screw abutment loosening as the most severe complication (3 of 60 implants; 5%). On the basis of this retrospective clinical review, the following conclusions were drawn: (1) successful function over a prolonged period and a minor complication rate of implant-tooth-supported telescopic maxillary dentures may be anticipated, and (2) the great variety of treatment modalities offered by tooth-implant support for telescopic prostheses appears to be useful as a treatment option for the maxilla in elderly patients.
Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue
2018-05-01
Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.
Recent Patents and Designs on Hip Replacement Prostheses
Derar, H; Shahinpoor, M
2015-01-01
Hip replacement surgery has gone through tremendous evolution since the first procedure in 1840. In the past five decades the advances that have been made in technology, advanced and smart materials innovations, surgical techniques, robotic surgery and methods of fixations and sterilization, facilitated hip implants that undergo multiple design revolutions seeking the least problematic implants and a longer survivorship. Hip surgery has become a solution for many in need of hip joint remedy and replacement across the globe. Nevertheless, there are still long-term problems that are essential to search and resolve to find the optimum implant. This paper reviews several recent patents on hip replacement surgery. The patents present various designs of prostheses, different materials as well as methods of fixation. Each of the patents presents a new design as a solution to different issues ranging from the longevity of the hip prostheses to discomfort and inconvenience experienced by patients in the long-term. PMID:25893020
Evolution of penile prosthetic devices
Burnett, Arthur L.
2015-01-01
Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases. PMID:25763121
Evolution of penile prosthetic devices.
Le, Brian; Burnett, Arthur L
2015-03-01
Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases.
Appearance of low signal intensity lines in MRI of silicone breast implants.
Stroman, P W; Rolland, C; Dufour, M; Grondin, P; Guidoin, R G
1996-05-01
Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.
Felice, Pietro; Pellegrino, Gerardo; Checchi, Luigi; Pistilli, Roberto; Esposito, Marco
2010-12-01
To evaluate whether 7-mm-long implants could be an alternative to longer implants placed in vertically augmented posterior mandibles. Sixty patients with posterior mandibular edentulism with 7-8 mm bone height above the mandibular canal were randomized to either vertical augmentation with anorganic bovine bone blocks and delayed 5-month placement of ≥10 mm implants or to receive 7-mm-long implants. Four months after implant placement, provisional prostheses were delivered, replaced after 4 months, by definitive prostheses. The outcome measures were prosthesis and implant failures, any complications and peri-implant marginal bone levels. All patients were followed to 1 year after loading. One patient dropped out from the short implant group. In two augmented mandibles, there was not sufficient bone to place 10-mm-long implants possibly because the blocks had broken apart during insertion. One prosthesis could not be placed when planned in the 7 mm group vs. three prostheses in the augmented group, because of early failure of one implant in each patient. Four complications (wound dehiscence) occurred during graft healing in the augmented group vs. none in the 7 mm group. No complications occurred after implant placement. These differences were not statistically significant. One year after loading, patients of both groups lost an average of 1 mm of peri-implant bone. There no statistically significant differences in bone loss between groups. When residual bone height over the mandibular canal is between 7 and 8 mm, 7 mm short implants might be a preferable choice than vertical augmentation, reducing the chair time, expenses and morbidity. These 1-year preliminary results need to be confirmed by follow-up of at least 5 years. © 2010 John Wiley & Sons A/S.
Removable partial denture on osseointegrated implants and natural teeth.
Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng
2007-01-01
Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.
Cordaro, Luca; Ercoli, Carlo; Rossini, Carlo; Torsello, Ferruccio; Feng, Changyong
2005-10-01
The clinical outcome of complete-arch fixed prostheses supported by implants and natural tooth abutments in patients with normal or reduced periodontal support has been reported by few studies, with controversial results. The purpose of this study was to report on the implant success rate, prosthetic complications, and the occurrence of tooth intrusion, when complete-arch fixed prostheses, supported by a combination of implants and teeth, were fabricated for patients with normal and reduced periodontal support. Nineteen patients with residual teeth that served as abutments were consecutively treated with combined tooth- and implant-supported complete-arch fixed prostheses and were retrospectively evaluated after a period varying from 24 to 94 months. Nine patients showed reduced periodontal support as a result of periodontal disease and treatment (RPS group), and 10 patients had normal periodontal support of the abutment teeth (more than 2/3 of periodontal support [NPS group]). Ninety implants and 72 tooth abutments were used to support 19 fixed partial dentures. Screw- and cement-retained metal-ceramic and metal-resin prostheses were fabricated with rigid and nonrigid connectors. Implant survival and success rates, occurrence of caries and tooth intrusion, and prosthetic complications were recorded. The number of teeth, implants, prosthetic units, fixed partial dentures, and nonrigid connectors were compared with a t test to assess differences between the 2 groups, while data for the occurrence of intrusions and prosthetic complications were compared with the Fisher exact test (alpha=.05). One of the 90 implants was lost (99% survival rate) over 24 to 94 months, while 3 implants showed more than 2 mm of crestal bone loss (96% success rate) over the same period. No caries were detected, but 5.6% (4/72) of the abutment teeth exhibited intrusion. Intrusion of abutment teeth was noted in 3 patients who had normal periodontal support (13% of teeth in NPS group) of the abutment teeth and was associated with nonrigid connectors. No intrusion of teeth was noted in the patients exhibiting reduced periodontal support regardless of the type of connector or when a rigid connector was used for either group. The number of intruded teeth was significantly greater in patients with intact periodontal support (P=.03). Complete-arch fixed prosthesis supported by implant and tooth abutments may be associated with intrusion of teeth with intact periodontal support when nonrigid connectors are used to join the implant- and tooth-supported sections of the prostheses. However, fixed partial dentures supported by implants and teeth with reduced periodontal support were not associated with tooth intrusion, regardless of the type of connectors used.
Manzotti, A.; Montironi, F.; Pullen, C.
2008-01-01
Recently mini-invasive joint replacement has become one of the hottest topics in the orthopaedic world. However, these terms have been improperly misunderstood as a “key-hole” surgery where traditional components are implanted with shorter surgical approaches, with few benefits and several possible dangers. Small implants as unicompartmental knee prostheses, patellofemoral prostheses and bi-unicompartmental knee prostheses might represent real less invasive procedures: Tissue sparing surgery, the Italian way to minimally invasive surgery (MIS). According to their experience the authors go through this real tissue sparing surgery not limited only to a small incision, but where the surgeons can respect the physiological joint biomechanics. PMID:19384616
Chen, Yu; Wang, Chao; Huang, Yuanding; Feng, Tianming; Zou, Huawei; Fan, Yubo
2017-07-01
Telescopic overdentures supported by the combination of natural teeth and implants have been thought a valuable treatment for the severely compromised partially edentulous patients. But the combination of teeth and implants involves highly complex biomechanical problems. This study is to evaluate biomechanical behaviors of the natural abutment teeth with the treatment of combined tooth-implant supported telescopic crown prostheses in mandible through 3D FEA. According to this study, the prosthetic option supported by a combination of teeth and implants and retained by double crowns could protect teeth and their periodontal support tissues acting as a rigid splint, and may be a valuable treatment option for partially edentulous patients with severely reduced remaining teeth in mandible.
Detection of orthopaedic implants by airport metal detectors.
Obremskey, William T; Austin, Tom; Crosby, Colin; Driver, Robin; Kurtz, Will; Shuler, Franklin; Kregor, Philip
2007-02-01
To report the effect of patient's body mass index (BMI), implant type, size, location, number, and material on detection by certified Transportation Security Administration (TSA) and Federal Aviation Administration (FAA) airport metal detectors set to today's standard sensitivity. Retrospective clinical study. Level 1 university trauma center. Ninety-six regularly scheduled trauma clinic patients with a wide variety of orthopaedic implants were enrolled in the study from August 2004 through December 2004. Patients walked through an airport arch metal detector and were also wanded with a handheld metal detector. Detection of implants by arch detector or wand was recorded. We also gathered information regarding BMI, location of implants, type, metal composition, and size. All unilateral prostheses (8/8) and bilateral prostheses (1/1) were detected. Subjects with 4 or fewer screws and no other implants were never detected by the arch metal detector (0/7). For the remaining 78 subjects, the 2 best predictors of detection by the arch were having plates of length >10 holes and having titanium nails (P < 0.001 for each predictor, Wald's test for effects in a logistic model). Prostheses, plates of length >10 holes, and titanium nails were the best predictors of detection by the arch. These 3 factors accounted for 42 of the 43 detections by the arch. Body mass index was not shown to affect detectability of orthopaedic implants.
Pellicer-Chover, Hilario; Peñarrocha-Oltra, David; Bagán, Leticia; Fichy-Fernandez, Antonio J.; Canullo, Luigi
2014-01-01
Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis. Implant success rates were evaluated for the two groups. The study sample included fifteen patients (nine women and six men) with a mean average age of 63.7 years. One hundred and forty-four implants were placed: 76 placed in healed sites and 68 placed immediately. Results: At the moment of prosthetic loading, keratinized mucosa width and probing depth were higher in immediate implants than delayed implants, with statistically significant differences. However, after six and twelve months, differences between groups had disappeared. Bone loss was 0.54 ± 0.39 mm for immediate implants and 0.66 ± 0.25 mm for delayed implants (p=0.201). No implants failed in either group. Conclusions: The present study with a short follow-up and a small sample yielded no statistically significant differences in implant success and peri-implant marginal bone loss between immediate and delayed implants with fixed full-arch prostheses. Peri-implant health showed no statistically significant differences for any of the studied parameters (crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis) at the twelve-month follow-up. Key words:Immediate implants, delayed implants, peri-implant health, success rate. PMID:24316712
Esposito, Marco; Pellegrino, Gerardo; Pistilli, Roberto; Felice, Pietro
2011-01-01
To evaluate whether 5 mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10 mm long implants in posterior atrophic jaws. Fifteen patients with bilateral atrophic mandibles (5-7 mm bone height above the mandibular canal), and 15 patients with bilateral atrophic maxillae (4-6 mm bone height below the maxillary sinus) and bone thickness of at least 8 mm, were randomised according to a splitmouth design to receive one to three 5 mm short implants or at least 10 mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes. In 5 augmented mandibles, the planned 10 mm long implants could not be placed and shorter implants (7 and 8.5 mm) had to be used instead. One year after loading no patient dropped out. Two long (8.5 mm in the mandible and 13 mm in the maxilla) implants and one 5 mm short maxillary implant failed. There were no statistically significant differences in failures or complications. Patients with short implants lost on average 1 mm of peri-implant bone and patients with longer implants lost 1.2 mm. This difference was statistically significant. This pilot study suggests that 1 year after loading, 5 mm short implants achieve similar if not better results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation since the treatment is faster, cheaper and associated with less morbidity, however their long-term prognosis is unknown.
Effect of ion implantation on the tribology of metal-on-metal hip prostheses.
Bowsher, John G; Hussain, Azad; Williams, Paul; Nevelos, Jim; Shelton, Julia C
2004-12-01
Nitrogen ion implantation (which considerably hardens the surface of the bearing) may represent one possible method of reducing the wear of metal-on-metal (MOM) hip bearings. Currently there are no ion-implanted MOM bearings used clinically. Therefore a physiological hip simulator test was undertaken using standard test conditions, and the results compared to previous studies using the same methods. N2-ion implantation of high carbon cast Co-Cr-Mo-on-Co-Cr-Mo hip prostheses increased wear by 2-fold during the aggressive running-in phase compared to untreated bearing surfaces, plus showing no wear reductions during steady-state conditions. Although 2 specimens were considered in the current study, it would appear that ion implantation has no clinical benefit for MOM.
Computed tomographic imaging of stapes implants.
Warren, Frank M; Riggs, Sterling; Wiggins, Richard H
2008-08-01
Computed tomographic (CT) imaging of stapes prostheses is inaccurate. Clinical situations arise in which it would be helpful to determine the depth of penetration of a stapes prosthesis into the vestibule. The accuracy of CT imaging for this purpose has not been defined. This study was aimed to determine the accuracy of CT imaging to predict the depth of intrusion of stapes prostheses into the vestibule. The measurement of stapes prostheses by CT scan was compared with physical measurements in 8 cadaveric temporal bones. The depth of intrusion into the vestibule of the piston was underestimated in specimens with the fluoroplastic piston by a mean of 0.5 mm when compared with the measurements obtained in the temporal bones. The depth of penetration of the stainless steel implant was overestimated by 0.5 mm when compared with that in the temporal bone. The type of implant must be taken into consideration when estimating the depth of penetration into the vestibule using CT scanning because the imaging characteristics of the implanted materials differ. The position of fluoroplastic pistons cannot be accurately measured in the vestibule. Metallic implants are well visualized, and measurements exceeding 2.2 mm increase the suspicion of otolithic impingement. Special reconstructions along the length of the piston may be more accurate in estimating the position of stapes implants.
SiC Protective Coating for Photovoltaic Retinal Prostheses
Lei, Xin; Kane, Sheryl; Cogan, Stuart; Lorach, Henri; Galambos, Ludwig; Huie, Philip; Mathieson, Keith; Kamins, Theodore; Harris, James; Palanker, Daniel
2016-01-01
Objective To evaluate PECVD SiC as a protective coating for retinal prostheses and other implantable devices, and to study their failure mechanisms in vivo. Approach Retinal prostheses were implanted in rats subretinally for up to 1 year. Degradation of implants was characterized by optical and scanning electron microscopy. Dissolution rates of SiC, SiNx and thermal SiO2 were measured in accelerated soaking tests in saline at 87°C. Defects in SiC films were revealed and analyzed by selectively removing the materials underneath those defects. Main results At 87°C SiNx dissolved at 18.3±0.3nm/day, while SiO2 grown at high temperature (1000°C) dissolved at 1.04±0.08A/day. SiC films demonstrated the best stability, with no quantifiable change after 112 days. Defects in thin SiC films appeared primarily over complicated topography and rough surfaces. Significance SiC coatings demonstrating no erosion in accelerated aging test for 112 days at 87°C, equivalent to about 10 years in vivo, can offer effective protection of the implants. Photovoltaic retinal prostheses with PECVD SiC coatings exhibited effective protection from erosion during the 4-month follow-up in vivo. The optimal thickness of SiC layers is about 560nm, as defined by anti-reflective properties and by sufficient coverage to eliminate defects. PMID:27323882
[Failure of zirconia-based prostheses on natural teeth and implants: focus on risk factors].
Dupont, N; Koenig, V; Vanheusden, A; Mainjot, A
2014-01-01
Cohesive fracture of the veneering ceramic (chipping) is the first cause of failure of zirconia-based prostheses on natural teeth and implants. Besides risk factors related to the material (thermal stresses generated during the manufacturing process, framework inappropriate design), there are some clinical risk factors, which can influence the restoration prognosis. Indeed, unfavorable occlusal relationships and/or the presence of parafunctions such as bruxism and clenching, which are frequent pathologies, engender significant overloading. A retrospective study was performed at the University Hospital Center (CHU) of Liege on 147 dental and implants prostheses, placed between May 2003 and January 2012. This study highlighted a significant correlation between chipping and the absence of an occlusal nightguard (p = 0.0048), the presence of a ceramic restoration as an antagonist (p = 0.013), the presence of occlusal parafunctions (p = 0.018), and the presence of implants as support of the restorations (p = 0.026). These results underline the importance of external stress and occlusal risk factors diagnosis, as the need to perform an occlusal nightguard to patients with parafunctions.
Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.
Drago, Carl
2012-01-01
With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.
Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad
2018-06-05
CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.
The long-term use of zygomatic implants: a 10-year clinical and radiographic report.
Aparicio, Carlos; Manresa, Carolina; Francisco, Karen; Ouazzani, Wafaa; Claros, Pedro; Potau, Josep M; Aparicio, Arnau
2014-06-01
The zygoma implant has been an effective option in the short-term management of the atrophic edentulous maxilla. To report on long-term outcomes in the rehabilitation of the atrophic maxilla using zygomatic (ZI) and regular implants (RI). 22 consecutive zygomatic patients in a maintenance program were included. Cumulative survival rate (CSR) of ZI, RI, prostheses, and complications were recorded during, at least, 10 years of loading. Implant mobility was tested using Periotest(®). Sinus health was radiographically and clinically assessed according to Lund-Mackay (L-M) score and Lanza and Kennedy survey, respectively. A satisfaction questionnaire and anatomical measurements were also performed. Patients received 22 prostheses, anchored on 172 implants. Forty-one were ZI. Three RI failed (10 years CSR = 97.71%). Two ZI were partly removed due to perimplant infection (10 years CSR = 95.12%). All patients maintained functional prostheses. One patient fractured framework twice. Loosening or fracturing screws happened in 11 patients. Seven patients fractured occlusal material. Four ZI abutments in two patients were disconnected because of uncomfortable prostheses. Alveolar height at the ZI head level on the right and left sides was 2.64 mm and 2.25 mm, respectively. Mean distance of ZI head center to ridge center, on the right and left sides was 4.54 mm and 5.67 mm, respectively. Mean Periotest values (PTv) of ZI were -4.375 PTv and -4.941 PTv before prostheses placement and after 10 years, respectively. Six patients experienced sinusitis 14-127 months postoperatively. 54.55% of the L-M scores did not present opacification (L-M = 0) in any sinus. Osteomeatal obstruction happened in eight patients (two bilateral). Two (9.09%) were diagnosed with sinusitis. Eighty-four percent reported satisfaction levels above 80%. 31.81% reported maximum satisfaction score (100%). The long-term rehabilitation of the severely atrophic maxillae using ZI is a predictable procedure. © 2012 Wiley Periodicals, Inc.
Selva-Otaolaurruchi, Eduardo J.; Montero, Javier; Sola-Ruiz, Fernanda
2015-01-01
Background This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). Material and Methods This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile-20 (OHIP-20) questionnaire and Oral Satisfaction Scale (OSS). Descriptive and bivariate statistical analysis was carried out applying χ², Pearson, Kruskal-Wallis, and Student t tests, transferring data into SPSS-Windows® software from a Microsoft® Excel spreadsheet. Results The OHIP-20 proved to be a valid instrument and provided reliable assessment of health-related quality of life among both the Spanish general population and edentulous patients. The control and study groups proved comparable, showing socio-demographic homogeneity. For patients with overdentures retained by means of the Locator® system, these restorations had significantly lower impact on quality of life (19 vs 33), both generally and for each individual questionnaire item, and much higher satisfaction with the state of their oral cavities (8.3 vs 5.3) than patients wearing dentures; both sets of data showed a direct linear relationship, so that as the level of impact on quality of life increased, perceived oral satisfaction worsened. Conclusions Patients rehabilitated with implant supported overdentures retained by the Locator® system, presented significantly lower levels of impact on their quality of life and significantly higher oral satisfaction than patients with conventional complete prostheses. Key words: Oral health-related quality of life, OHIP-20, OSS, overdentures, dental implants, complete prostheses, Locator® system. PMID:26034930
Implant use for primary hip and knee arthroplasty: are we getting it right first time?
Ng Man Sun, Stephen; Gillott, Elizabeth; Bhamra, Jagmeet; Briggs, Tim
2013-06-01
Implants used for hip and knee arthroplasties have recently come under increased scrutiny. In England, a large variety of prostheses are currently being used. With the need for savings within the NHS of up to £20 billion over the next five years, we should be 'getting it right first time' by using the most reliable implants with proven survivorship. The 8th Annual Report from the NJR (2011) reporting on prostheses used in 2010 was analysed to determine whether implants had published survivorship data. This study demonstrates that the majority of implants did have long-term results but a small percentage had no published data. The cost of these implants was calculated to see if the implants provided best value for money based on survivorship. Implant choice was also correlated to revision rates published in the NJR report (2011) to help determine whether their continued use was justified. Copyright © 2013 Elsevier Inc. All rights reserved.
Ibañez, Juan C; Tahhan, Marcelo J; Zamar, Juan A; Menendez, Alicia B; Juaneda, Agustina M; Zamar, Nicolas J; Monqaut, Jose L
2005-11-01
The high success rate of dental implants has changed the quality of life for many patients. Immediate loading finds its application in some clinical cases and certainly adds another modality of treatment for the implant patient. Starting with a few implants immediately loaded with a bar overdenture in the mandible, the concept of immediate loading evolved to loading multiple implants in both the maxilla and mandible. In this investigation, 41 consecutive patients who needed full-arch restorations were treated with 343 double acid-etched surface implants between May 1998 and March 2004. The sample included smokers and bruxers. Twenty-three mandibular and 26 maxillary cases were treated, loading the implants within 48 hours, by using resin provisional prostheses, metal-reinforced provisional prostheses, or definitive prostheses (metal-acrylic or metal-ceramic). All implants were followed for 12 to 74 months. Follow-up consisted of clinical as well as radiographic examination. Furthermore, resonance frequency analysis was done in most of the implants during the last 2 years. The success rate obtained was 99.42% (only two mandibular implants that are still surviving were considered failures). The bone level was measured every year. The average radiographic bone level change was 0.56 mm at 12, 0.76 mm at 24, 0.84 mm at 36, 0.82 mm at 48, 0.83 mm at 60, and 0.94 mm at 72 months. A high success rate can be achieved when double acid-etched surface implants are immediately loaded with fixed full-arch restorations in the maxilla and mandible.
Comparative study of design and PCL-substituting systems of total knee prosthesis.
Adam, R; Orban, C; Orban, H
2014-01-01
The aim of this study is to assess postoperative results obtained by different knee implants. The main implant types differences are given by generally implant design and by PCL substituting systems that are used. Between 04.2004 - 02.2012 we have performed 506 total knee arthroplasties (TKA), on a group of 460 patients. Our choice, was for cemented total knee prostheses, using PCL-substituting systems. Regarding general design and PCL-substituting systems of the implant we had divided the main group in three lots. In order to assess post operative result we had used the American Knee Society Score(AKSS). All prostheses types that we had implanted, had registered satisfactory values of AKSS. Our study showed that one group scored higher values of AKSS, compared the other two, but there are not statistical semnificative differences (p=0,09). Celsius.
Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H
1999-05-31
The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.
Brinkmann, V; Radetzki, F; Gutteck, N; Delank, S; Zeh, A
2017-03-01
The aim of this study was to analyze bone remodeling around the Nanos® (Smith & Nephew) and Metha® (Aesculap AG) implants as a function of varus/valgus stem positioning. In 75 patients with diagnosed coxarthrosis, either Nanos® (n= 51) or Metha® (n= 24) prostheses were implanted. Digital assessment of plain radiographs immediately, 97 days, and 381 days after THA showed no clinically-relevant migration, angulation, or change in offset and center of rotation. The DEXA scans showed significant BMD changes in Gruen zones 1 (-12.8%), 2 (-3.3%), 6 (+6.4%), and 7(-7.8%)(t-test). The pre/postoperative CCD for the Nanos® was 129°/ 135° and for the Metha® 131°/ 127°. Linear regression analysis showed no prediction for BMD by postoperative CCD or stem type. In conclusion, there was no clinically-relevant influence on proximal femur BMD according to varus/valgus implantation of the Nanos® or Metha® prostheses.
Cakir, Onur; Kazancioglu, Hakki Oguz; Celik, Gozde; Deger, Sabire; Ak, Gulsum
2014-07-01
The aim of this study was to compare the satisfaction and quality of life (QoL) in a group of patients using mandibular complete dentures, implant-retained overdentures, removable partial dentures (RPDs), or implant-supported fixed partial dentures (FPDs). A total of 116 patients (aged 36 to 81, mean age 58 ± 10.03 years) were assigned to four groups (n = 29) and treated with mandibular implant-retained overdentures, implant-supported FPDs (two implants/three unit FPDs), conventional complete dentures, or RPDs. The groups were well matched in terms of gender, age, and the edentulous period. All patients had edentulous maxillary arches and completely or partially edentulous mandibles. All prostheses were mandibular prostheses. The OHIP-14, OHQoL-UK, and SF-36 surveys were used to determine QoL before implant surgery and 1 year after prosthetic treatment. The baseline and 1-year data from 116 patients were analyzed. A significant improvement was found among the QoL scales for all groups (p < 0.05). The most significant improvement was found in the implant-retained overdenture group (15.67 ± 2.47), while the least improvement was found among the implant-supported FPD group (5.14 ± 2.08). The SF-36 test revealed no differences between the before and after treatment scores for general health, pain, vitality, social function, and physical function difficulties (p > 0.05). The only significant difference was found for mental health (p = 0.011). A positive influence on oral health-related QoL was observed in all groups. The QoL values were the most improved in the implant-retained overdenture group. © 2014 by the American College of Prosthodontists.
van Rosendael, Philippe J; Delgado, Victoria; Bax, Jeroen J
2018-06-01
The incidence of new-onset conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with new-generation prostheses remains debated. This systematic review analyses the incidence of PPI after TAVI with new-generation devices and evaluates the electrical, anatomical, and procedural factors associated with PPI. In addition, the incidence of PPI after TAVI with early generation prostheses was reviewed for comparison. According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist, this systematic review screened original articles published between October 2010 and October 2017, reporting on the incidence of PPI after implantation of early and new-generation TAVI prostheses. Of the 1406 original articles identified in the first search for new-generation TAVI devices, 348 articles were examined for full text, and finally, 40 studies (n = 17 139) were included. The incidence of a PPI after the use of a new-generation TAVI prosthesis ranged between 2.3% and 36.1%. For balloon-expandable prostheses, the PPI rate remained low when using an early generation SAPIEN device (ranging between 2.3% and 28.2%), and with the new-generation SAPIEN 3 device, the PPI rate was between 4.0% and 24.0%. For self-expandable prostheses, the PPI rates were higher with the early generation CoreValve device (16.3-37.7%), and despite a reduction in PPI rates with the new Evolut R, the rates remained relatively higher (14.7-26.7%). When dividing the studies according to the highest (>26.0%) and the lowest (<12.1%) quintile of PPI rate, patients within the highest quintile were more frequently women when compared with the lowest quintile group (50.9% vs. 46.3%, P < 0.001). Pre-existent conduction abnormalities (electrical factor), calcification of the left ventricular outflow tract (anatomical factor), and balloon valvuloplasty and depth of implantation (procedural factors) were associated with increased risk of PPI. The rate of PPI after TAVI with new-generation devices is highly variable. Specific recommendations for implantation of each prosthesis, taking into consideration the presence of pre-existent conduction abnormalities and anatomical factors, may be needed to reduce the risk of PPI.
Cercadillo-Ibarguren, Iñaki; Sánchez-Torres, Alba; Figueiredo, Rui; Valmaseda-Castellón, Eduard
To describe the clinical outcomes and complications related to provisional prostheses after full-arch implant-supported rehabilitation by means of an immediate loading protocol. This retrospective cohort study included patients who were consecutively treated with full-arch implant-supported restorations with a minimum of four implants (Replace Select Tapered TiUnite, Nobel Biocare AB) per arch and conical abutments (multi-unit, Nobel Biocare AB) by means of an immediate loading protocol. The surgical procedures were performed between May 2006 and June 2014 by a single oral surgeon. Demographic, surgical, and prosthetic variables were collected, and biologic and mechanical complications were registered. A total of 61 maxillae (57%) and 46 mandibles (43%) were treated in 88 patients (40 men and 48 women) with a mean age of 62.4 years. A total of 558 implants were placed, 295 in postextraction sockets. A total of 331 implants (59.3%) were placed in the maxilla and 227 (40.7%) in the mandible. Within a 9-month period, 18 prostheses (16.8%) fractured (15 maxillary and 3 mandibular); in nine of these patients the opposing dentition was a full-arch, implant-supported restoration, and in the remaining nine patients, it was natural dentition. Six (1.1%) maxillary and three (0.5%) mandibular implants failed. A high implant survival rate is expected in the short term following this immediate loading protocol. Fracture of the provisional prosthesis is a common finding, affecting 17% of patients, and is significantly more prevalent in patients with bruxism and in maxillary prostheses.
Characterization of In-Body to On-Body Wireless Radio Frequency Link for Upper Limb Prostheses.
Stango, Antonietta; Yazdandoost, Kamya Yekeh; Negro, Francesco; Farina, Dario
2016-01-01
Wireless implanted devices can be used to interface patients with disabilities with the aim of restoring impaired motor functions. Implanted devices that record and transmit electromyographic (EMG) signals have been applied for the control of active prostheses. This simulation study investigates the propagation losses and the absorption rate of a wireless radio frequency link for in-to-on body communication in the medical implant communication service (MICS) frequency band to control myoelectric upper limb prostheses. The implanted antenna is selected and a suitable external antenna is designed. The characterization of both antennas is done by numerical simulations. A heterogeneous 3D body model and a 3D electromagnetic solver have been used to model the path loss and to characterize the specific absorption rate (SAR). The path loss parameters were extracted and the SAR was characterized, verifying the compliance with the guideline limits. The path loss model has been also used for a preliminary link budget analysis to determine the feasibility of such system compliant with the IEEE 802.15.6 standard. The resulting link margin of 11 dB confirms the feasibility of the system proposed.
Characterization of In-Body to On-Body Wireless Radio Frequency Link for Upper Limb Prostheses
Stango, Antonietta; Yazdandoost, Kamya Yekeh; Negro, Francesco; Farina, Dario
2016-01-01
Wireless implanted devices can be used to interface patients with disabilities with the aim of restoring impaired motor functions. Implanted devices that record and transmit electromyographic (EMG) signals have been applied for the control of active prostheses. This simulation study investigates the propagation losses and the absorption rate of a wireless radio frequency link for in-to-on body communication in the medical implant communication service (MICS) frequency band to control myoelectric upper limb prostheses. The implanted antenna is selected and a suitable external antenna is designed. The characterization of both antennas is done by numerical simulations. A heterogeneous 3D body model and a 3D electromagnetic solver have been used to model the path loss and to characterize the specific absorption rate (SAR). The path loss parameters were extracted and the SAR was characterized, verifying the compliance with the guideline limits. The path loss model has been also used for a preliminary link budget analysis to determine the feasibility of such system compliant with the IEEE 802.15.6 standard. The resulting link margin of 11 dB confirms the feasibility of the system proposed. PMID:27764182
NASA Astrophysics Data System (ADS)
Palleri, Francesca; Baruffaldi, Fabio; Angelini, Anna Lisa; Ferri, Andrea; Spezi, Emiliano
2008-12-01
In external beam radiotherapy the calculation of dose distribution for patients with hip prostheses is critical. Metallic implants not only degrade the image quality but also perturb the dose distribution. Conventional treatment planning systems do not accurately account for high-Z prosthetic implants heterogeneities, especially at interfaces. The materials studied in this work have been chosen on the basis of a statistical investigation on the hip prostheses implanted in 70 medical centres. The first aim of this study is a systematic characterization of materials used for hip prostheses, and it has been provided by BEAMnrc Monte Carlo code. The second aim is to evaluate the capabilities of a specific treatment planning system, Pinnacle 3, when dealing with dose calculations in presence of metals, also close to the regions of high-Z gradients. In both cases it has been carried out an accurate comparison versus experimental measurements for two clinical photon beam energies (6 MV and 18 MV) and for two experimental sets-up: metallic cylinders inserted in a water phantom and in a specifically built PMMA slab. Our results show an agreement within 2% between experiments and MC simulations. TPS calculations agree with experiments within 3%.
Wojtovicz, Eduardo; España-Lopez, Antonio; Jimenez-Guerra, Alvaro; Monsalve-Guil, Loreto; Ortiz-Garcia, Ivan; Serrera-Figallo, Maria-Angeles
2018-01-01
Background The aim of this prospective study was to report the outcome of treatment with implants inserted after tooth extraction and immediately loaded. Material and Methods Fifty-six patients with single tooth loss were treated with 116 IPX Galimplant® implants with internal connections and a sandblasted, acid-etched surface. All implants were placed after tooth extraction using a flapless approach without bone regeneration, and they were then immediately loaded with cemented acrylic prostheses. After a period of three months, definitive cemented ceramic prostheses were placed. Patients were examined throughout a total of 4 years of follow-up. Marginal bone loss and survival rates were evaluated using digital periapical radiographs, taking into account clinical variables such as age, gender, smoking, history of periodontitis, etiology of extraction, placement site, diameter, and implant length. The Mann-Whitney U and Kruskal-Wallis non-parametric tests were used to compare differences between subgroups created based on the different clinical variables identified. Results Clinical results indicate an implant survival and success rate of 97.4%. Three implants were lost. Of the 116 immediate acrylic single crowns initially placed, 113 were replaced with definitive ceramic crowns after 3 months. A total of 77.8% of implants were inserted in the maxilla, while 22.2% were inserted in the mandible. No further complications were reported after the follow-up period (4 years). The mean marginal bone loss was 0.67 mm ± 0.40 mm. No differences were found among the subgroups of study patients. Conclusions This study indicates that dental implants that are inserted after tooth extraction and immediately loaded may constitute a successful and predictable alternative implant treatment. Key words:Dental implants, post-extraction implants, fresh sockets, immediate loading, immediate prostheses, implant dentistry. PMID:29476669
Lazzeri, Davide; Agostini, Tommaso; Bocci, Guido; Giannotti, Giordano; Fanelli, Giovanni; Naccarato, Antonio Giuseppe; Danesi, Romano; Tuccori, Marco; Pantaloni, Marcello; D'Aniello, Carlo
2011-10-01
Concerns have been raised recently regarding the increasing number of reports of non-Hodgkin lymphoma (NHL) that developed in close proximity to silicone or saline breast implants. In particular, an increased risk of anaplastic large cell lymphoma (ALCL) in patients with breast prostheses has been proposed. We reviewed clinical and pathologic findings in 40 women who received a diagnosis of breast NHL arising in association with breast implants and of 27 patients who had a diagnosis of ALCL with breast involvement reported in the published literature. Among the 40 reported cases of prosthesis-associated breast lymphomas, 28 were anaplastic lymphoma kinase-1-negative (ALK-1(-)) ALCLs, whereas of 27 ALCLs in patients without implants found in the literature, only 10 were ALK-1(-). The finding of 28 cases of breast ALK-1(-) ALCL occurring in patients with implants compared with 10 cases in women without implants is in favor of an association between silicone breast prostheses and ALK-1(-) ALCL. Although the incidence of this type of lymphoma remains remarkably low given that breast prostheses have been widely used for decades, clinical and pathologic evidence for a causative role is becoming dramatically strong. The histologic, phenomenologic, and clinical similarities of the majority of implant-related ALK-1(-) ALCLs suggest a common mechanism, especially when compared with the counterpart of patients without implants in which very few and highly dishomogeneous cases of the same malignancy were detected. There is convincing evidence that primary implant-related ALK-1(-) ALCL represents a distinct clinicopathologic entity that has been inappropriately fitted into the category of systemic ALK-1(-) ALCL. Thus it should be recognized as a separate category and classified on its own. Copyright © 2011 Elsevier Inc. All rights reserved.
21 CFR 872.3645 - Subperiosteal implant material.
Code of Federal Regulations, 2010 CFR
2010-04-01
... intended to construct custom prosthetic devices which are surgically implanted into the lower or upper jaw... intended to provide support for prostheses, such as dentures. (b) Classification. Class II. ...
Maló, Paulo; Friberg, Bertil; Polizzi, Giovanni; Gualini, Federico; Vighagen, Torbjörn; Rangert, Bo
2003-01-01
Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. The purpose of this prospective clinical multicenter study was to evaluate the outcome of implants placed in incisor, canine, and premolar regions in maxillas or mandibles. Implants were loaded with provisional crowns and bridges on the same day or within a few days and were followed up for 1 year during function. Four centers treated 76 patients each in need of an implant-retained prosthesis in the anterior and premolar regions in the maxilla or mandible. A total of 116 titanium implants with machined surfaces (Brånemark System , Nobel Biocare AB, Gothenburg, Sweden) were placed: 74 in maxillas and 42 in mandibles. Eighty-seven prostheses were made, of which 63 were single crowns and 24 were bridges (supported by 53 splinted implants). Twenty-two implants in 14 patients were placed in fresh extraction sites. The goal with the preparation and insertion technique was to achieve good primary implant stability and a minimum implant insertion torque of 30 Ncm before the implant was completely seated. The occlusion was adjusted to eliminate direct contact with the provisional prostheses. After 6 months, the patients received their permanent prostheses. Sixty-seven patients were followed for 1 year. Five implants were lost in five patients, three in the maxilla and two in the mandible. Four of the lost implants were single-tooth replacements and one was splinted. The cumulative survival rate (CSR) was 95.7% for all implants after 1 year and 93.7% and 98.1% for single-tooth and splinted implants, respectively. There were no implant losses in the extraction sites. The CSR of 96% at 1 year indicates that immediate function of Brånemark System implants placed in incisor to premolar regions in both jaws is a viable concept. More failures occurred with single-tooth replacements (6.3%) than with splinted implants (1.9%).
Updates in inflatable penile prostheses.
Henry, Gerard D; Wilson, Steven K
2007-11-01
Throughout history, many attempts to correct erectile dysfunction (ED) have been recorded. For the last 35 years, intracavernosal inflatable prostheses have been used, and these devices have undergone almost constant enhancement. The three-piece inflatable penile prosthesis has the highest patient satisfaction rates and lowest mechanical revision rates of almost any medically implanted device.
Langton, David John; Sidaginamale, Raghavendra Prasad; Avery, Peter; Waller, Sue; Tank, Ghanshyabhai; Lord, James; Joyce, Thomas; Cooke, Nick; Logishetty, Raj; Nargol, Antoni Viraf Francis
2016-01-01
Objectives To determine risk factors for revision in patients implanted with a commonly used metal on metal (MoM) hip replacement. Design Retrospective cohort study in combination with a prospective national retrieval study (Northern Retrieval Registry (NRR)). Setting Combined orthopaedic unit in combination with the NRR. Participants All patients implanted with a DePuy Pinnacle MoM hip prostheses by the 2 senior authors were invited to attend for a review which included clinical examination, blood metal ion measurements, radiographs and targeted imaging. Explanted components underwent wear analysis using validated methodology and these results were compared with those obtained from the NRR. Results 489 MoM Pinnacle hips were implanted into 434 patients (243 females and 191 males). Of these, 352 patients attended the MoM recall clinics. 64 patients had died during the study period. For the purposes of survival analysis, non-attendees were assumed to have well-functioning prostheses. The mean follow-up of the cohort as a whole was 89 months. 71 hips were revised. Prosthetic survival for the whole cohort was 83.6% (79.9–87.3) at 9 years. The majority of explanted devices exhibited signs of taper junction failure. Risk factors for revision were bilateral MoM prostheses, smaller Pinnacle liners, and implantation in 2006 and later years. A significant number of devices were found to be manufactured out of their specifications. This was confirmed with analysis of the wider data set from the NRR. Conclusions This device was found to have an unacceptably high revision rate. Bilateral prostheses, those implanted into female patients and devices implanted in later years were found to be at greater risk. A significant number of explanted components were found to be manufactured with bearing diameters outside of the manufacturer's stated tolerances. Our findings highlight the clinical importance of hitherto unrecognised variations in device production. PMID:27130159
Lian, Meifei; Zhao, Kai; Feng, Yunzhi; Yao, Qian
The reliability of combining natural teeth and implants in one removable prosthesis is controversial. This systematic review was conducted to evaluate the prognosis of combined tooth/implant-supported double-crown-retained removable dental prostheses (DCR-RDPs) and to compare them with solely implant-supported prostheses with a minimum observation period of 3 years. Electronic database (PubMed, Embase, Central, and SCI) and manual searches up to August 2016 were conducted to identify human clinical studies on tooth/implant-supported DCR-RDPs. Literature selection and data extraction were accomplished by two independent reviewers. Meta-analyses of survival and complication rates were performed separately for combined tooth/implant-supported and solely implant-supported DCRRDPs. Among the initially identified 366 articles, 17 were included in a quantitative analysis. The estimated overall cumulative survival rate (CSR) for implants in combined tooth/implant-supported DCRRDPs was 98.72% (95% confidence interval [95% CI]: 96.98% to 99.82%), and that for implants in solely implant-supported DCR-RDPs was 98.83% (95% CI: 97.45% to 99.75%). The summary CSR for abutment teeth was 92.96% (95% CI: 85.38% to 98.12%). Double-crown-retained dentures with both abutment types showed high CSRs, most of which were approximately 100%. Regarding prosthetic maintenance treatment, the estimated incidence for patients treated with combined tooth/implant-supported RDPs was 0.164 (95% CI: 0.089 to 0.305) per patient per year (T/P/Y) and that for patients restored with solely implant-supported RDPs was 0.260 (95% CI: 0.149 to 0.454) T/P/Y. Based on four studies with combined tooth/implant-supported DCR-RDPs, no intrusion phenomena were encountered. Subject to the limitations of the present review, combining remaining teeth and implants in DCR-RDPs is a reliable and predictable treatment modality for partially edentulous patients. Comparable high survival rates and minor biologic or technical complications are observed for combined tooth/implant-supported and solely implant-supported DCR-RDPs. Due to the heterogeneity of the included studies, the results must be interpreted with caution.
In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.
Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko
2013-03-01
Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions. Copyright © 2012 Orthopaedic Research Society.
Borg, Peter; Puryer, James; McNally, Lisa; O’Sullivan, Dominic
2016-01-01
This paper reviews the literature regarding possible complications, complication-free survival, and overall survival of fixed dental prostheses that use both implants and natural teeth as abutments. The paper also provides clinical guidelines for treatment based on this literature review. An electronic search utilizing the MEDLINE, BIOSIS Citation Index, and Web of Science™ Core Collection databases was undertaken, and a review of the 25 selected texts studying 22 different patient cohorts was carried out. From a total of 1610 implants reviewed, 40 were lost (33 due to loss of integration and 7 due to fracture), whereas, out of a total of 1301 teeth, 38 were lost, of which 16 were due to fracture. Seventy-three cases of tooth intrusion were detected. From a total of 676 frameworks reviewed (metal n = 645, Zirconia n = 31), 7 fractured, while veneer material fracture occurred in 70 out of 672 bridges. Overall, 502 out of 531 tooth-implant fixed prostheses (TIPFs) remained functional, and 336 out of 439 prostheses showed no technical or biological complications and remained functional. Rigid TIFPs permanently cemented to teeth with sufficient coronal structure and with limited use of prosthetic attachments offer a good long-term treatment option to patients with good oral hygiene following sound implant placement. This mode of treatment should be used when free-standing implant-supported options may not be possible. Larger randomized control studies and other clinical studies comparing tooth-to-implant-connected treatment with other forms of treatment are needed to better understand the place of TIFP treatment in oral rehabilitation. PMID:29563458
Aschoff, H-H; Juhnke, D-L
2016-05-01
In 1999 the first endo-exo femoral prosthesis (EEFP) was implanted in Germany in a patient who had suffered a traumatic above-knee amputation. This procedure involves a skeletally anchored exoprosthetic device that is inserted into the residual femur. The distal part of the implant protrudes transcutaneously and allows attachment to a prosthetic limb which provides direct force transmission to the external prosthetic components. The technique originated from dental implantology and helps to avoid possible problems resulting from treatment of amputated limbs using socket prostheses. In the meantime, durability times of over 10 years have now helped to invalidate the initially well-founded reservations held against the procedure. What advantages can be achieved by osseointegrated and percutaneously channeled prostheses and which problems had to be overcome for treatment. Critical evaluation of data from patients operated on in Lübeck, Germany from January 2003 to December 2014. With osseointegrated and percutaneously channeled prostheses permanent durability times can be achieved. Infection-associated soft tissue problems at the site of skin protrusion (stoma) can be successfully prevented. The creation of this so-called stoma means acceptance of a possible bacterial portal of entry into the body. Patient satisfaction has so far been high, postoperative rehabilitation is simplified and the technique could possibly lower the costs of medical treatment. Endo-exo prostheses have proved to be successful for more than 15 years. A critical appraisal of the indications as well as a close cooperation between the surgeon, orthopedic technician and the associated rehabilitation facilities with the patient are the basis for the long-term success of this relatively new treatment approach.
Al-Otaibi, Hanan Nejer; Akeel, Riyadh Fadul
2014-01-01
To determine the effect of increased torque of the abutment screw and retorquing after 10 minutes on implant-supported fixed prostheses. Two strain gauges (SGs) were attached to four implants stabilized on an acrylic resin mandible. Four implant-supported frameworks were constructed to represent passive fit (PF) and different amounts of misfit (MF1, MF2, and MF3). Vertical misfit was measured using a traveling microscope. Each framework was torqued to 35 Ncm (the manufacturer's recommendation) and 40 Ncm, and the preload was recorded immediately and again after retorquing 10 minutes later (torque stage). The smallest gap was observed under the PF framework. Three-way analysis of variance revealed significant effects of the framework, torque value, and torque stage on preload. The PF showed the highest mean preload under both torque values. An independent-sample t test between the torque values revealed a statistically significant difference only for MF1 and MF2. A dependent-sample t test of the torque stage revealed a statistically significant difference at a torque value of 35 Ncm under the PF and MF3 frameworks. Increasing the torque value beyond the manufacturer's recommended amount and retorquing of the screws at 10 minutes after the initial torque did not necessarily lead to a significant increase in preload in full-arch implant-supported fixed prostheses, particularly under non-passively fitting frameworks.
a Review of Retinal Prosthesis Approaches
NASA Astrophysics Data System (ADS)
Kien, Tran Trung; Maul, Tomas; Bargiela, Andrzej
Age-related macular degeneration and retinitis pigmentosa are two of the most common diseases that cause degeneration in the outer retina, which can lead to several visual impairments up to blindness. Vision restoration is an important goal for which several different research approaches are currently being pursued. We are concerned with restoration via retinal prosthetic devices. Prostheses can be implemented intraocularly and extraocularly, which leads to different categories of devices. Cortical Prostheses and Optic Nerve Prostheses are examples of extraocular solutions while Epiretinal Prostheses and Subretinal Prostheses are examples of intraocular solutions. Some of the prostheses that are successfully implanted and tested in animals as well as humans can restore basic visual functions but still have limitations. This paper will give an overview of the current state of art of Retinal Prostheses and compare the advantages and limitations of each type. The purpose of this review is thus to summarize the current technologies and approaches used in developing Retinal Prostheses and therefore to lay a foundation for future designs and research directions.
Microleakage of different sealing materials in access holes of internal connection implant systems.
Park, Sung-Do; Lee, Yoon; Kim, Yu-Lee; Yu, Sang-Hui; Bae, Ji-Myung; Cho, Hye-Won
2012-09-01
Current implant systems cannot completely prevent microleakage from the access holes of screw-retained implant prostheses, which may constitute risks to the clinical success of the implants. The purpose of this study was to evaluate the levels of microleakage through the access holes of screw-retained implant prostheses sealed with different materials. An implant with an internal hexagonal configuration was connected to a temporary abutment with an acrylic resin crown. The apical 6.5 mm of the access hole was filled with 1 of the following materials: cotton pellet, silicone sealing material, vinyl polysiloxane, or gutta-percha. The remaining coronal 3 mm was sealed with composite resin. Cyclic loading with 21 N at 1 Hz was applied 16,000 times to the specimens in 0.5% basic fuchsin solution according to the long axis of the tooth. Basic fuchsin dye which penetrated into the internal wall of the abutment through the access hole was dissolved with methyl alcohol. Then the absorbance was measured by a spectrophotometer at 540 nm to evaluate the degree of microleakage. The results were statistically analyzed with 1-way ANOVA and the Tukey HSD test. From greatest to least, the levels of microleakage were in the following order: cotton pellet, silicone sealing material, vinyl polysiloxane, and gutta-percha. The microleakage associated with gutta-percha was not significantly different from that of vinyl polysiloxane. When sealing the access holes of screw-retained implant prostheses, gutta-percha or vinyl polysiloxane would help reduce microleakage. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Chen, P; Yu, S; Zhu, G
2012-12-01
The aim of the current study was to investigate the psychosocial impact of dental aesthetics among patients who received anterior implant-supported prostheses. The current study is a cross-sectional evaluation involving 115 individuals who had gone through treatment at the dental clinics of general hospitals. Participants completed the Chinese version of the psychosocial impact of dental aesthetics questionnaire (PIDAQ) before implantation and six months after crown restoration. Basic demographic information was recorded. Six months after implant crown restoration, participants were asked to self-assess their own oral aesthetics compared to before implantation. A total of 106 patients completed the study. PIDAQ scores correlated significantly with the self-assessment of the degree of oral aesthetics. Six months after crown restoration, the two factors (social impact and aesthetic attitude) decreased and the dental self-confidence score increased significantly compared to pre-implantation scores. Gender and education level significantly affected PIDAQ. Anterior implant-supported prostheses significantly affected the patients' psychosocial perception. Implantation of missing anterior teeth can significantly improve patients' negative psychosocial impact of dental aesthetics. Gender and education level are correlated with the degree of improvement. The PIDAQ can be used in assessing the psychosocial effects of implantation in missing anterior teeth.
Progress in the clinical development and utilization of vision prostheses: an update
Brandli, Alice; Luu, Chi D; Guymer, Robyn H; Ayton, Lauren N
2016-01-01
Vision prostheses, or “bionic eyes”, are implantable medical bionic devices with the potential to restore rudimentary sight to people with profound vision loss or blindness. In the past two decades, this field has rapidly progressed, and there are now two commercially available retinal prostheses in the US and Europe, and a number of next-generation devices in development. This review provides an update on the development of these devices and a discussion on the future directions for the field. PMID:28539798
Felício, Y
2000-01-01
The author describes a method of calf augmentation by a silicone prosthesis implant for correction of asymmetrical legs or aesthetic problems. Preference is given to the placement of soft silicone implants (Glitzentein implants); they are more natural looking than hard implants. The implants are placed over both heads of the gastrocnemius muscle or beneath the fascia cruris superficialis. Operations were performed from November 1985 to August 1999. One hundred patients were studied: 95 female and 5 male. Two hundred calf implants were performed: 188 soft implants (Glitzenstein), 6 hard implants (Aiache), and 6 together on the same leg (Glitzenstein and Aiache implants). No infection problems, prosthesis rupture, or hematomas occurred. There were four seromas, but they disappeared in 15 days. Four prostheses were removed in two patients who did not like the final result. One prosthesis changed place, to the upper part of the calf. The operation is performed under sedative and local anesthesia, with an incision of approximately 4 to 5 cm in the popliteal pleat, at the same height as the fascia cruris. To date, no functional problem or muscular dysfunction has been provoked by silicone prosthesis implants. The patient walks 8 h after the surgery. We selected 500 patients who received implants in the legs with calf prostheses, fat implants, and prosthesis and fat implant together, during 14 years of follow-up, but the focus of this paper is a calf implant with prosthesis in 100 patients with 200 calf prosthesis implants.
Brand, Stephan; Klotz, Johannes; Hassel, Thomas; Petri, Maximilian; Ettinger, Max; Krettek, Christian; Goesling, Thomas; Bach, Friedrich-Wilhelm
2013-10-01
The purpose of this study was to evaluate the different temperature levels whilst drilling cemented and cementless hip prostheses implanted in bovine femora, and to evaluate the insulating function of the cement layer. Standard hip prostheses were implanted in bovine donor diaphyses, with or without a cement layer. Drilling was then performed using high-performance-cutting drills with a reinforced core, a drilling diameter of 5.5 mm and cooling channels through the tip of the drill for constantly applied internal cooling solution. An open type cooling model was used in this setup. Temperature was continuously measured by seven thermocouples placed around the borehole. Thermographic scans were also performed during drilling. At the cemented implant surface, the temperature never surpassed 24.7 °C when constantly applied internal cooling was used. Without the insulating cement layer (i.e. during drilling of the cementless bone-prosthesis construct), the temperature increased to 47 °C. Constantly applied internal cooling can avoid structural bone and soft tissue damage during drilling procedures. With a cement layer, the temperatures only increased to non-damaging levels. The results could be useful in the treatment of periprosthetic fractures with intraprosthetic implant fixation.
Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model
Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen
2015-01-01
Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses. PMID:25695057
Ortorp, Anders; Jemt, Torsten
2008-09-01
Comparative long-term knowledge of different framework materials in the partially edentulous implant patient is not available. To report and compare 10-year data on free-standing implant-supported partial prostheses with laser-welded titanium (test) and conventional gold alloy (control) frameworks. Altogether, 52 partially edentulous patients were consecutively provided with laser-welded prostheses (n = 60) in the partially edentulous lower jaw (test group). A control group of 52 randomly selected patients with gold alloy castings (n = 60) was used for comparison. Clinical and radiographic 10-year data were retrospectively collected and evaluated for both groups. The overall 10-year implant cumulative survival rate (CSR) was 93.0% (loaded implants, 96.4%), with a 10-year implant CSR of 91.5 and 94.7% for test and control implants, respectively (p > .05). Out of a total of 22 lost implants, 17 implants (77.3%) were shorter than 10 mm. The overall 10-year prosthesis CSR was 93.7%, with a corresponding 10-year CSR of 88.4 and 100% for test and control groups, respectively (p < .05). Average 10-year bone loss was 0.46 mm (SD 0.47) and 0.69 mm (SD 0.53) for the test and control groups (p < .001), respectively. Only 1% of the implants had >3 mm accumulated bone loss after 10 years. Altogether, 10 of the prostheses in both groups had implant component mechanical problems (8.3%). None of the frameworks or implants fractured, but more fractures of porcelain veneers were observed in the test group (p < .05). The protocol of implant treatment in the partially edentulous jaw functioned well during 10 years, although prosthodontic maintenance was required. However, laser-welded titanium frameworks presented more problems as compared with gold alloy frameworks. More loaded implants were lost (p < .05), and higher incidence of porcelain chipping was noted in the test group (p < .05). However, bone loss was on an average lower for the test group during the 10 years of follow-up (p < .001).
Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria; Francischone, Carlos Eduardo; de Mattos, Maria da Gloria Chiarello
2004-08-01
For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used. The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy. Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05). Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (P<.001) in the gold alloy group when the screws were tightened (Au=12.6 +/- 3.0 microm, compared to Ti=30.1 +/- 6.4 microm). When the side opposite the tightened side was analyzed, there was no significant difference between the gold alloy and titanium groups (Au=69.2 +/- 24.9 microm and Ti=94.2 +/- 39.6 microm). The electroerosion procedure significantly (P<.001) reduced the gaps at the interfaces for both groups under all conditions. Comparison between groups after electroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium). Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.
Jayasinghe, Rasika Manori; Perera, Janana; Jayasinghe, Vajira; Thilakumara, Indika P; Rasnayaka, Sumudu; Shiraz, Muhammad Hanafi Muhammad; Ranabahu, Indra; Kularatna, Sanjeewa
2017-07-27
Our objective was to assess awareness, attitudes, need and demand on replacement of missing teeth according to edentulous space, age, gender, ethnicity, educational level and socio-economical status of the patient. 76.2% of the study group was opined that the missing teeth should be replaced by prosthetic means. Majority were keen in getting them replaced mainly for the comfort in mastication. Although 77.9 and 32.9% were aware of the removable prostheses and implants respectively, only 25.2% knew about tooth supported bridges as an option of replacement of missing teeth. Participants' awareness on tooth and implant supported prostheses is at a higher level. Participants' opinion on need of regular dental visit was statistically significant when gender, ethnicity and education level were considered. The highest demand for replacement of missing teeth was observed in Kennedy class I and II situations in both upper and lower arches. Demand for fixed prostheses was significantly highest in Kennedy class II in upper and lower arches. In conclusion, although removable prosthodontic options are known to most of the patients, their awareness on tooth and implant supported prostheses is also at a higher level. The highest demand for replacement of missing teeth is by patients with Kennedy class I and II situations whereas Kennedy class II being the category with highest demand for fixed prostheses. We recommend that the location of missing teeth to be considered as a priority when educating patients on the most appropriate prosthetic treatment options. Dentists' involvement in educating patients on prosthetic options needs to be improved.
Echazarreta-Gallego, Estíbaliz; Pola-Bandrés, Guillermo; Arribas-Del Amo, María Dolores; Gil-Romea, Ismael; Sousa-Domínguez, Ramón; Güemes-Sánchez, Antonio
2017-10-01
Breast prostheses exposure is probably the most devastating complication after a skin sparing mastectomy (SSM) and implant-based, one-stage, breast reconstruction. This complication may occur in the immediate post-operative period or in the weeks and even months after the procedure. In most cases, the cause is poor skin coverage of the implant due to skin necrosis. Eight consecutive cases of implant exposure (or risk of exposure) due to skin necrosis in SSM patients over a period of 5 years, all patients were treated using a random epigastric rotation flap, executed by the same medical team. A random epigastric flap (island or conventional rotation flap) was used to cover the skin defect. All the patients completed the procedure and all prostheses were saved; there were no cases of flap necrosis or infection. Cases of skin necrosis after SSM and immediate implant reconstruction, in which the implant is at risk of exposure, can be successfully treated with a random epigastric rotation flap.
Fernandez-Estevan, Lucia; Selva-Otaolaurruchi, Eduardo J; Montero, Javier; Sola-Ruiz, Fernanda
2015-07-01
This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile-20 (OHIP-20) questionnaire and Oral Satisfaction Scale (OSS). Descriptive and bivariate statistical analysis was carried out applying χ², Pearson, Kruskal-Wallis, and Student t tests, transferring data into SPSS-Windows® software from a Microsoft® Excel spreadsheet. The OHIP-20 proved to be a valid instrument and provided reliable assessment of health-related quality of life among both the Spanish general population and edentulous patients. The control and study groups proved comparable, showing socio-demographic homogeneity. For patients with overdentures retained by means of the Locator® system, these restorations had significantly lower impact on quality of life (19 vs 33), both generally and for each individual questionnaire item, and much higher satisfaction with the state of their oral cavities (8.3 vs 5.3) than patients wearing dentures; both sets of data showed a direct linear relationship, so that as the level of impact on quality of life increased, perceived oral satisfaction worsened. Patients rehabilitated with implant supported overdentures retained by the Locator® system, presented significantly lower levels of impact on their quality of life and significantly higher oral satisfaction than patients with conventional complete prostheses.
Ortorp, Anders; Jemt, Torsten
2006-01-01
Long-term follow-up studies for more than 5 years are not available on laser-welded titanium frameworks. To report and compare 10-year data on implant-supported prostheses in the edentulous mandible provided with laser-welded titanium frameworks and conventional gold alloy frameworks. Altogether, 155 patients were consecutively treated with prostheses at abutment level with two generations of fixed laser-welded titanium frameworks (test groups). A control group of 53 randomly selected patients with conventional gold alloy castings was used for comparison. Clinical and radiographic 10-year data were collected for the three groups. All patients followed-up for 10 years (n=112) still had fixed prostheses in the mandible (cumulative success rate [CSR] 100%). The overall 10-year cumulative success rate (CSR) was 92.8 and 100.0% for titanium and gold alloy frameworks, respectively. Ten-year implant cumulative survival rate (CSR) was 99.4 and 99.6% for the test and control groups, respectively. Average 10-year bone loss was 0.56 (SD 0.45) mm for the titanium group and 0.77 (SD 0.36) mm for the control group (p < 0.05). The most common complications for titanium frameworks were resin or veneer fractures, soft tissue inflammation, and fractures (12.9%) of the metal frame. Loose and fractured implant screw components were below 3%. Excellent overall long-term results with 100% CSR could be achieved with the present treatment modality. Fractures of the metal frames and remade prostheses were more common for the laser-welded titanium frameworks, and the first generation of titanium frameworks worked poorly when compared with gold alloy frameworks during 10 years (p < 0.05). However, on average more bone loss was observed for implants supporting gold alloy frameworks during 10 years. The reasons for this difference are not clear.
Sprecher, Christoph M; Wimmer, Markus A; Milz, Stefan; Taeger, Georg
2009-01-01
Background and purpose Particles originating from the articulating surfaces of hip endoprostheses often induce an inflammatory response, which can be related to implant failure. We therefore analyzed the metal content in capsular tissue from 44 McKee-Farrar metal-on-metal hip prostheses (with 3 different head sizes) and we also analyzed the morphological structure of layers located on articulating surfaces. Methods Atomic absorption spectrometry (AAS) was used to analyze the metal content in capsular tissue. Visually detectable carbon layers located on the articulating surfaces were evaluated using scanning electron microscopy (SEM), energy-dispersive Xray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). Results Metallic debris was detected in all capsular tissue samples but no statistically significant differences in metal content were found in relation to implant head size. The morphological characteristics of the different layer zones allowed an exact analysis of contact and non-contact areas. Furthermore, surface layers appear to have a protective function because they can prevent sharp-edged particles from damaging the prostheses surface. Interpretation The implant head size does not appear to influence the amount of metallic debris. The layers obviously act like a lubricating agent because the protection function does not occur in regions without layers where the metal surface often shows numerous scratches. As layers are not generated immediately after the implantation of hip prostheses, these findings may at least partially explain the high amount of wear early after implantation. PMID:19421914
Analysis of the causes of dental implant fracture: A retrospective clinical study.
Stoichkov, Biser; Kirov, Dimitar
2018-01-01
Fracture of osseointegrated dental implants is the most severe mechanical complication. The aim of the present study was to analyze possible causative factors for implant body fracture. One hundred and one patients with 218 fitted implants and a follow-up period of 3 to 10 years were studied. Factors associated with biomechanical and physiologic overloading such as parafunctional activity (eg, bruxism), occlusion, and cantilevers, and factors related to the planning of the dental prosthesis, available bone volume, implant area, implant diameter, number of implants, and their inclination were tracked. The impact of their effect was analyzed using the Bonferroni-corrected post-hoc Mann-Whitney test for each group. The incidence of dental implant fracture was 2.3% in the investigated cases. Improper treatment planning, bruxism, and time of the complication setting in were the main factors leading to this complication. Typical size effect was established only for available bruxism, occlusal errors, and their activity duration. These complications were observed most often with single crown prostheses, and in combination with parafunctional activities such as bruxism and lack of implant-protected occlusion. Occlusal overload due to bruxism or inappropriate or inadequate occlusion as a single factor or a combination of these factors during the first years after the functional load can cause implant fracture. Fracture of the implant body more frequently occurred with single crowns than with other implant-supported fixed dental prostheses.
Henderson, Eric R; Pepper, Andrew M; Letson, G Douglas
2012-04-01
Growing prostheses accommodate skeletally immature patients with bone tumors undergoing limb-preserving surgery. Early devices required surgical procedures for lengthening; recent devices lengthen without surgery. Expenses for newer expandable devices that lengthen without surgery are more than for their predecessors but overall reimbursement amounts are not known. We sought to determine reimbursement amounts associated with lengthening of growing prostheses requiring surgical and nonsurgical lengthening. We retrospectively reviewed 17 patients with growing prostheses requiring surgical expansion and eight patients with prostheses capable of nonsurgical expansion. Insurance documents were reviewed to determine the reimbursement for implantation, lengthening, and complications. Growth data were obtained from the literature. Mean reimbursement amounts of surgical and nonsurgical lengthenings were $9950 and $272, respectively. Estimated reimbursements associated with implantation of a growing prosthesis varied depending on age, sex, and location. The largest difference was found for 4-year-old boys with distal femoral replacement where reimbursement for expansion to maturity for surgical and nonsurgical lengthening prostheses would be $379,000 and $208,000, respectively. For children requiring more than one surgical expansion, net reimbursements were lower when a noninvasive lengthening device was used. Annual per-prosthesis maintenance reimbursements to address complications for surgical and nonsurgical lengthening prostheses were $3386 and $1856, respectively. This study showed that reimbursements for lengthening of growing endoprostheses capable of nonsurgical expansion may be less expensive in younger patients, particularly male patients undergoing distal femur replacement, than endoprostheses requiring surgical lengthening. Longer outcomes studies are required to see if reimbursements for complications differ between devices. Level III, economic and decision analysis. See the Guidelines for Authors for a complete description of levels of evidence.
Zitzmann, Nicola Ursula; Marinello, Carlo Paolo
2002-01-01
The aim of the present article is to review some of the technical treatment options for implant prostheses restoring the edentulous mandible, mainly based on the Brånemark system. Clinical and technical aspects are discussed for the three established concepts: (1) implant-supported fixed prosthesis, (2) removable implant-supported overdenture, and (3) combined implant-retained and soft tissue-supported overdenture prosthesis. The framework of an implant-supported fixed screw-retained prosthesis can be processed in gold, Co-Cr alloy, or titanium with casting, laser-welding, or milling techniques. To improve the stability and retention of a conventional complete denture, one to four implants are indicated, and unsplinted (single attachments) or splinted designs (bar systems) can be applied. The design of the overdenture prosthesis must be carefully planned according to the requirements to ensure adequate stability and optimal form, contour, and esthetics, and the patient's best comfort. A large variety of different treatment modalities exist for both the fixed and removable mandibular implant prosthesis. Clinical and technical aspects should be considered at the beginning of the treatment to: (1) select the optimal implant position, (2) establish an adequate number of functional units, (3) select the appropriate retainers, and (4) apply the best technique for framework processing and veneering.
Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan
2017-12-21
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.
Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Youn, Inchan
2017-01-01
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time. PMID:29267230
Schweiger, Josef; Neumeier, Peter; Stimmelmayr, Michael; Beuer, Florian; Edelhoff, Daniel
2013-04-01
Implant-supported prosthetic restorations with veneered crowns and fixed dental prostheses are a proven, scientifically accepted treatment concept in fixed prosthodontics. However, in this area of indication there is a comparatively high technical complication rate, which occurs mainly in the area of the superstructure in the form of minor or major chipping of the veneering material. Various studies have shown that purely implant-supported restorations are subjected to higher loading than those on natural abutment teeth due to the special biomechanical conditions. A possible approach to prevent technical complications is to create higher stability for the implant superstructure through the use of high-strength materials. This would, however, result in undiminished overloading being transmitted to the implant components and could cause increased technical and biological complications. This article describes a new procedure for the use of replaceable veneers made from high-performance polymer material on modified implant abutments. By storing digital datasets for the veneer section, it can be replaced easily and quickly if it becomes worn or is fractured. A reduction in the stresses for the implant components and biological structures under the polymer is also to be expected due the material properties of polymers.
Jenny, J Y; Boeri, C
2001-01-01
A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.
Long-term results after artificial iris implantation in patients with aniridia.
Rickmann, Annekatrin; Szurman, Peter; Januschowski, Kai; Waizel, Maria; Spitzer, Martin S; Boden, Karl T; Szurman, Gesine B
2016-07-01
The custom-made, flexible artificial iris developed by HumanOptics and Koch can reconstruct the anterior segment of patients with aniridia. The aim of this study was to evaluate the long-term clinical outcome and complication spectrum after artificial iris implantation and the role of the embedded fiber mesh in view of specific complications. In this retrospective interventional case series, patients received an artificial iris between 2004 and 2013. Only eyes with a minimum follow-up period of 2 years were included. Indications were congenital, traumatic, or iatrogenic aniridia. The artificial iris was used either with or without embedded fiber mesh for partial or full prostheses. We included 34 patients (mean age 48.8 years; SD ±17.2) with a mean follow-up of 50.0 months (SD ±18.9 months). No repositioning of prostheses was necessary. In cases of keratopathy (17.6 %) visual function increased from baseline mean 1.6 logMAR (SD ±0.7) to 1.2 logMAR (SD ±0.7) after artificial iris implantation. The remaining iris tissue darkened during the follow-up in 23.5 % (83.3 % with and 10.7 % without mesh), 8.8 % developed glaucoma (50 % with and 0 % without mesh) and 14.7 % needed consecutive surgery after prostheses implantation (50 % with and 7.1 % without mesh). In three out of seven trauma cases (42.9 %) silicone oil was spilled into the anterior chamber after 2.5 years on average. The artificial iris prosthesis revealed a good clinical outcome in terms of long-term stability, cosmetic appearance, visual function, and represents a good functional iris diaphragm for compartmentalisation. Complications such as glaucoma, darkening of iris tissue, and need for consecutive anterior segment surgery are clearly associated with implants with integrated fiber mesh, but not to those without. Hence, the use of full iris prostheses without embedded fiber mesh, even in cases with remnant iris, and the use of slightly smaller implants than officially recommended may be beneficial.
NASA Astrophysics Data System (ADS)
McIntosh, Benjamin Patrick
Blindness due to Age-Related Macular Degeneration and Retinitis Pigmentosa is unfortunately both widespread and largely incurable. Advances in visual prostheses that can restore functional vision in those afflicted by these diseases have evolved rapidly from new areas of research in ophthalmology and biomedical engineering. This thesis is focused on further advancing the state-of-the-art of both visual prostheses and implantable biomedical devices. A novel real-time system with a high performance head-mounted display is described that enables enhanced realistic simulation of intraocular retinal prostheses. A set of visual psychophysics experiments is presented using the visual prosthesis simulator that quantify, in several ways, the benefit of foveation afforded by an eye-pointed camera (such as an eye-tracked extraocular camera or an implantable intraocular camera) as compared with a head-pointed camera. A visual search experiment demonstrates a significant improvement in the time to locate a target on a screen when using an eye-pointed camera. A reach and grasp experiment demonstrates a 20% to 70% improvement in time to grasp an object when using an eye-pointed camera, with the improvement maximized when the percept is blurred. A navigation and mobility experiment shows a 10% faster walking speed and a 50% better ability to avoid obstacles when using an eye-pointed camera. Improvements to implantable biomedical devices are also described, including the design and testing of VLSI-integrable positive mobile ion contamination sensors and humidity sensors that can validate the hermeticity of biomedical device packages encapsulated by hermetic coatings, and can provide early warning of leaks or contamination that may jeopardize the implant. The positive mobile ion contamination sensors are shown to be sensitive to externally applied contamination. A model is proposed to describe sensitivity as a function of device geometry, and verified experimentally. Guidelines are provided on the use of spare CMOS oxide and metal layers to maximize the hermeticity of an implantable microchip. In addition, results are presented on the design and testing of small form factor, very low power, integrated CMOS clock generation circuits that are stable enough to drive commercial image sensor arrays, and therefore can be incorporated in an intraocular camera for retinal prostheses.
Chaverri-Fierro, D; Lobo-Escolar, L; Espallargues, M; Martínez-Cruz, O; Domingo, L; Pons-Cabrafiga, M
The implementation of National Prostheses Registries allows us to obtain a large amount of data and make conclusions in order to improve the use of them. Sweden was the first country to implement a National Prostheses Registry in 1979. Catalonia has been doing this since 2005. The aim of our study is to analyse the evidence that supports primary total hip replacement in Catalonia in the last 9 years, based on the Arthroplasty Registry of Catalonia (RACat). A review of the literature was carried out of the prosthesis (acetabular cups/stems) reported in the RACat between the period 2005 to 2013 in the following databases: ODEP (Orthopaedic Data Evaluation Panel), TRIP database, PubMed, and Google Scholar. Those prostheses implanted in less than 10 units (182 acetabular components corresponding to 49 models/228 stems corresponding to 63 models) were excluded. A total of 18,634 (99%) implanted acetabular cups were analysed out of a total number of 18,816, corresponding to 74 different models. In 18 models (2527 acetabular cups) no clinical evidence to support its use was found. An analysis was performed on 19,367 (98.84%) out of a total number of 19,595 implanted stems, corresponding to 75 different models. In 16 models (1845 stems) no clinical evidence was found to support their use. Variable evidence was found in the 56 models of acetabular cups (16,107) and 59 models of stems (17,522), most of it corresponding to level iv clinical evidence. There was a significant number implanted prostheses evaluated (13.56% acetabular cups/9.5% stems) for which no clinical evidence was found. The elevated number of models is highlighted (49 types for acetabular cups/63 types for stems) with less than 10 units implanted, which corresponds to only 1% of the total implants. The use of arthroplasty registers is shown to be an extremely helpful tool that allows analyses and conclusions to be made for the follow-up and post-marketing surveillance period. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Hurley, Eoghan T; O'Sullivan, Katie E; Segurado, Ricardo; Hurley, John P
2015-01-01
Sutureless aortic valve prostheses are anchored by radial force in a mechanism similar to that of transcatheter aortic valve implantation. Transcatheter aortic valve implantation is associated with an increased permanent pacemaker (PPM) requirement in a significant proportion of patients. We undertook a meta-analysis to examine the incidence of PPM insertion associated with sutureless compared with conventional surgical aortic valve replacement. A systematic review was conducted in accordance with the Prisma guidelines. All searches were performed on August 10, 2014. Studies between 2007 and 2014 were included in the search. A total of 832 patients were included in the sutureless group and 3,740 in the conventional group. Aortic cross-clamp (39.8 vs 62.4 minutes; P < 0.001) and cardiopulmonary bypass (64.9 vs 86.7 minutes; P = 0.002) times were shorter in the sutureless group. Permanent pacemaker implantation rate was higher in the sutureless cohort (9.1% vs 2.4%; P = 0.025). Sutureless aortic valve prostheses are associated with significantly shorter cardiopulmonary bypass and aortic cross-clamp times and a higher incidence of PPM insertion than conventional. Further investigation of the prognostic significance is required.
Biomaterials and biologics in craniofacial reconstruction.
Engstrand, Thomas
2012-01-01
Complications related to surgery, including infection, wound dehiscence, and implant protrusion, are costly and may cause severe morbidity to patients. The choice of implants materials is critical for a successful outcome, particularly in craniofacial reconstructions. This review discusses the potential benefits and drawbacks of biologically active materials used for craniofacial bone repair as alternatives to inert implant prostheses.
Visual Prostheses: The Enabling Technology to Give Sight to the Blind
Maghami, Mohammad Hossein; Sodagar, Amir Masoud; Lashay, Alireza; Riazi-Esfahani, Hamid; Riazi-Esfahani, Mohammad
2014-01-01
Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices. PMID:25709777
Essayed, Walid I; Unadkat, Prashin; Hosny, Ahmed; Frisken, Sarah; Rassi, Marcio S; Mukundan, Srinivasan; Weaver, James C; Al-Mefty, Ossama; Golby, Alexandra J; Dunn, Ian F
2018-03-02
OBJECTIVE Endoscopic endonasal approaches are increasingly performed for the surgical treatment of multiple skull base pathologies. Preventing postoperative CSF leaks remains a major challenge, particularly in extended approaches. In this study, the authors assessed the potential use of modern multimaterial 3D printing and neuronavigation to help model these extended defects and develop specifically tailored prostheses for reconstructive purposes. METHODS Extended endoscopic endonasal skull base approaches were performed on 3 human cadaveric heads. Preprocedure and intraprocedure CT scans were completed and were used to segment and design extended and tailored skull base models. Multimaterial models with different core/edge interfaces were 3D printed for implantation trials. A novel application of the intraoperative landmark acquisition method was used to transfer the navigation, helping to tailor the extended models. RESULTS Prostheses were created based on preoperative and intraoperative CT scans. The navigation transfer offered sufficiently accurate data to tailor the preprinted extended skull base defect prostheses. Successful implantation of the skull base prostheses was achieved in all specimens. The progressive flexibility gradient of the models' edges offered the best compromise for easy intranasal maneuverability, anchoring, and structural stability. Prostheses printed based on intraprocedure CT scans were accurate in shape but slightly undersized. CONCLUSIONS Preoperative 3D printing of patient-specific skull base models is achievable for extended endoscopic endonasal surgery. The careful spatial modeling and the use of a flexibility gradient in the design helped achieve the most stable reconstruction. Neuronavigation can help tailor preprinted prostheses.
Papaspyridakos, Panos; Lal, Kunal
2013-06-01
To report the clinical results and technical complications with computer-assisted design/computer-assisted manufacturing (CAD/CAM) zirconia, implant fixed complete dental prostheses (IFCDPs) after 2-4 years in function. Fourteen consecutive edentulous patients (16 edentulous arches) were included in this study. Ten of the patients were women and four were men, with an average age of 58 years (range: 35-71). Ten mandibular and six maxillary arches were restored with porcelain fused to zirconia (PFZ) IFCDPs. Of the 16 arches, 14 received one-piece and 2 received segmented two-piece IFCDPs, respectively. The mean clinical follow-up period was 3 years (range: 2-4). At the last recall appointment, biological and technical parameters of dental implant treatment were evaluated. The implant and prosthesis survival rate following prosthesis insertion was 100% up to 4-year follow-up. The prostheses in 11 of the 16 restored arches were structurally sound, exhibited favorable soft tissue response, esthetics, and patient satisfaction. Five IFCDPs (31.25%) in four patients exhibited porcelain veneer chipping. Chipping was minor in three prostheses (three patients) and was addressed intraorally with polishing (one prosthesis) or composite resin (two prostheses). One patient with maxillary and mandibular zirconia IFCDP exhibited major porcelain chipping fractures which had to be repaired in the laboratory. Function, esthetics, and patient satisfaction were not affected in three of the four fracture incidents. Median crestal bone loss was 0.1 mm (0.01-0.2 mm). The presence of parafunctional activity, the IFCDP as opposing dentition, and the absence of occlusal night guard were associated with all the incidents of ceramic chipping. CAD/CAM zirconia IFCDPs are viable prosthetic treatment after 2-4 years in function, but not without complications. The porcelain chipping/fracture was the most frequent technical complication, with a 31.25% chipping rate at the prosthesis level. Despite the technical complications, increased patient satisfaction was noted. © 2012 John Wiley & Sons A/S.
Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.
Spazzin, Aloísio Oro; Bacchi, Atais; Trevisani, Alexandre; Farina, Ana Paula; Dos Santos, Mateus Bertolini
2016-01-01
This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the frameworks and the abutments was evaluated with an optical microscope using the single-screw test. Data were analyzed using one-way analysis of variance and Tukey test (α = .05). The one-piece casted frameworks presented significantly higher vertical misfit values than those found for framework cemented on prepared abutments and laser welding techniques (P < .001 and P < .003, respectively). Laser welding and framework cemented on prepared abutments are effective techniques to improve the adaptation of three-unit implant-supported prostheses. These techniques presented similar fit.
Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses
Sohn, Byoung-Sup; Heo, Seong-Joo; Koak, Jai-Young; Kim, Seong-Kyun
2011-01-01
PURPOSE This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS The mean strain values (MSV) for the working sides were 151.83 µε, 176.23 µε, and 131.07 µε for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 µε, 72.64 µε, and 98.93 µε for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01). PMID:21503186
Prosthetic implant treatment of the edentulous maxilla with overdenture.
Inversini, M
2006-10-01
The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.
Tomaszewski, P. K.; Verdonschot, N.; Bulstra, S. K.
2010-01-01
An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants. PMID:20309731
EAO consensus conference: economic evaluation of implant-supported prostheses.
Beikler, Thomas; Flemmig, Thomas F
2015-09-01
There are various alternatives for the management of oral conditions that may lead to or already have lead to partial or full edentulism. Economic evaluations measure the efficiency of alternative healthcare interventions and provide useful information for decision-making and the allocation of scarce resources. The current English literature dealing with "cost-effectiveness" of dental implant therapy versus different alternative treatment modalities, that is, complete and fixed partial dentures, root canal, and periodontal treatment, has been included in this narrative review. Due to the high heterogeneity within the literature, a meta-analysis could not be conducted. The available evidence from economic evaluations indicated that for the treatment of central incisors with irreversible pulpitis and coronal lesions, root canal treatments were most cost-effective initial treatment options. When initial root canal treatments failed, orthograde retreatments were most cost-effective. When root canal retreatments failed, extractions and replacement with single implant-supported crowns were more cost-effective compared to fixed or removable partial dentures. In the treatment of periodontitis in molars with Class I furcation invasion, non-surgical periodontal therapy was more effective and costed less than implant-supported single crowns. For the replacement of single missing teeth, two evaluations indicated that implant-supported single crowns provided better outcomes in terms of greater quality-adjusted tooth years or survival rates at lower costs compared to fixed partial prostheses. Another economic evaluation found that implant-supported crowns costed more, but provided greater survival rates compared to fixed partial dentures. For the restoration of edentulous mandibles, two evaluations indicated that overdentures retained by two or four implants improved oral health-related quality of life outcomes, but costed more than complete dentures. To better assess the efficiency of implant-supported prostheses in various clinical conditions, more economic evaluations are needed that follow well-established methodologies in health economics. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Retinal prostheses: progress toward the next generation implants
Ghezzi, Diego
2015-01-01
In the last decade, various clinical trials proved the capability of visual prostheses, in particular retinal implants, to restore a useful form of vision. These encouraging results promoted the emerging of several strategies for neuronal stimulation aiming at the restoration of sight. Besides the traditional approach based on electrical stimulation through metal electrodes in the different areas of the visual path (e.g., the visual cortex, the lateral geniculate nucleus, the optic nerve, and the retina), novel concepts for neuronal stimulation have been mostly exploited as building blocks of the next generation of retinal implants. This review is focused on critically discussing recent major advancements in the field of retinal stimulation with particular attention to the findings in the application of novel concepts and materials. Last, the major challenges in the field and their clinical implications will be outlined. PMID:26347602
Pellicer-Chover, Hilario; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Bagán, Leticia; Peñarrocha-Diago, María
2016-01-01
Background To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm length of the zygomatic implants 12 months after prosthetic delivery. Results Twenty-two patients participated in the study, receiving 22 prostheses anchored on 148 implants (44 were zygomatic and 94 were conventional implants). The mean right and left prosthetic arm length was 5.9±2.4 mm and 6.1±2.7 mm, respectively, with no statistically significant differences between them (p=0.576). The mean scores referred to comfort/retention, speech, functionality and overall satisfaction were high - no correlation being found between prosthetic arm length and patient satisfaction (p=0.815). Conclusions No relationship could be identified between prosthetic arm length (palatal position) and patient satisfaction. Key words:Zygomatic implants, patient satisfaction, zygomatic prosthesis, prosthetic arm length. PMID:26946206
The use of prostheses in skeletally immature patients.
Abudu, Adesegun; Grimer, Robert; Tillman, Roger; Carter, Simon
2006-01-01
Prosthetic reconstruction in the skeletally immature patient is challenging because of the necessity to cope with expected disruption of limb growth after resection of one or more major growth plates and the high demands placed on implants by young patients. Although prosthetic reconstruction in children is fraught with many problems, it is usually possible to obtain a good functional limb at skeletal maturity. Extendable prostheses are readily acceptable to patients and their parents. The availability of noninvasive extendable prostheses is expected to lead to fewer complications, fewer surgical interventions, and even improved function. This article reviews the indication, evolution, and clinical and functional results of extendable endoprostheses, drawing from experience in the last 30 years of using such prostheses in children.
Combined registration of 3D tibia and femur implant models in 3D magnetic resonance images
NASA Astrophysics Data System (ADS)
Englmeier, Karl-Hans; Siebert, Markus; von Eisenhart-Rothe, Ruediger; Graichen, Heiko
2008-03-01
The most frequent reasons for revision of total knee arthroplasty are loosening and abnormal axial alignment leading to an unphysiological kinematic of the knee implant. To get an idea about the postoperative kinematic of the implant, it is essential to determine the position and orientation of the tibial and femoral prosthesis. Therefore we developed a registration method for fitting 3D CAD-models of knee joint prostheses into an 3D MR image. This rigid registration is the basis for a quantitative analysis of the kinematics of knee implants. Firstly the surface data of the prostheses models are converted into a voxel representation; a recursive algorithm determines all boundary voxels of the original triangular surface data. Secondly an initial preconfiguration of the implants by the user is still necessary for the following step: The user has to perform a rough preconfiguration of both remaining prostheses models, so that the fine matching process gets a reasonable starting point. After that an automated gradient-based fine matching process determines the best absolute position and orientation: This iterative process changes all 6 parameters (3 rotational- and 3 translational parameters) of a model by a minimal amount until a maximum value of the matching function is reached. To examine the spread of the final solutions of the registration, the interobserver variability was measured in a group of testers. This variability, calculated by the relative standard deviation, improved from about 50% (pure manual registration) to 0.5% (rough manual preconfiguration and subsequent fine registration with the automatic fine matching process).
Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.
Bernhart, Gunda; Koob, Andreas; Schmitter, Marc; Gabbert, Olaf; Stober, Thomas; Rammelsberg, Peter
2012-08-01
The objective of this retrospective study was to compare biological and technical complications of implant-supported and tooth-implant-supported double crown-retained dentures (DCRDs) with those of tooth-supported DCRDs. Sixty-three DCRDs were monitored. One study group included 16 prostheses with a combination of implants and natural teeth as double crowns (ti group), whereas in the second study group, 19 dentures were retained exclusively on implants (ii group); a third study group with 28 exclusively tooth-supported dentures served as controls (tt group). Tooth loss, implant failure, and technical complications (loss of retention of primary crown, abutment screw loosening, loss of facing, fracture of resin denture teeth and fracture of saddle resin) were analysed. During the observation period of 24 months, no implants or teeth were lost in the ti group and three technical complications were recorded. In the ii group, two implants were lost, two cases of peri-implantitis occurred and four technical complications were observed. In the tt group, two cases of tooth loss and seven technical complications were observed. At the time of the last examination, all prostheses of the ti group and the ii group were functional. Patients of these two study groups reported high satisfaction with both function and aesthetics with no significant difference between the two groups. Treatment with DCRDs showed comparable results in the three study groups. The 2-year results indicate that double crowns can be recommended for implant and combined tooth-implant-retained dentures.
Treatment of peri-implant diseases: a review of the literature and protocol proposal.
Armas, Joshé; Culshaw, Shauna; Savarrio, Lee
2013-01-01
Over 100,000 implants were placed in the UK in 2010. As the numbers of patients with implant-retained prostheses increases, operators are encountering an increasing number of biological implant complications, most commonly peri-implant mucositis and peri-implantitis. The effective management of these complications is crucial to maintain patients' oral health. In particular, in contrast to common periodontal infections, some peri-implant infections may benefit from surgical intervention as a first line approach. This article reviews the literature on the treatment options for peri-implant mucositis and peri-implantitis and proposes a protocol for their treatment.
Krisch, I; Hosticka, B J
2007-01-01
Microsystem technologies offer significant advantages in the development of neural prostheses. In the last two decades, it has become feasible to develop intelligent prostheses that are fully implantable into the human body with respect to functionality, complexity, size, weight, and compactness. Design and development enforce collaboration of various disciplines including physicians, engineers, and scientists. The retina implant system can be taken as one sophisticated example of a prosthesis which bypasses neural defects and enables direct electrical stimulation of nerve cells. This micro implantable visual prosthesis assists blind patients to return to the normal course of life. The retina implant is intended for patients suffering from retinitis pigmentosa or macular degeneration. In this contribution, we focus on the epiretinal prosthesis and discuss topics like system design, data and power transfer, fabrication, packaging and testing. In detail, the system is based upon an implantable micro electro stimulator which is powered and controlled via a wireless inductive link. Microelectronic circuits for data encoding and stimulation are assembled on flexible substrates with an integrated electrode array. The implant system is encapsulated using parylene C and silicone rubber. Results extracted from experiments in vivo demonstrate the retinotopic activation of the visual cortex.
Surface evaluation of orthopedic hip implants marketed in Brazil
NASA Astrophysics Data System (ADS)
Souza, M. M.; Trommer, R. M.; Maru, M. M.; Roesler, C. R. M.; Barros, W. S.; Dutra, M. S.
2016-07-01
One of the factors that contribute to the quality of total hip prostheses is the degree of accuracy in the manufacturing of the joint surfaces. The dimensional control of joint components is important because of its direct influence on the durability and, consequently, in the patients’ life quality. This work presents studies on the form and roughness of orthopedic hip prostheses marketed in Brazil. The results provide data for quality control of the surfaces of the femoral heads and acetabular components of hip prostheses and indicate the need of improvement in the procedures used to this control.
Re-operation for aortic and mitral prosthetic dysfunctions.
Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B
1985-01-01
The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.
Oral rehabilitation of patients after maxillectomy. A systematic review.
Dos Santos, D M; de Caxias, F P; Bitencourt, S B; Turcio, K H; Pesqueira, A A; Goiato, M C
2018-05-01
Patients who have maxillectomy can be rehabilitated with reconstructive surgery or obturator prostheses with or without osseointegratable implants. To identify studies on possible treatments in this group, we systematically searched the Scopus, Embase, PubMed/Medline, and Cochrane databases to collect data on patients' characteristics, radiotherapy, and results related to speech, swallowing, mastication or diet, chewing, aesthetics, and quality of life. Of the 1376 papers found, six were included, and one other was included after an additional search of references. A total of 252 patients were included, and of them, 86 had reconstructive surgery, 91 were treated with obturator prostheses, 39 had reconstructive surgery or obturator prostheses associated with implants, and 36 had reconstruction plus an obturator prosthesis. Data on radiotherapy were incomplete. There is a lack of consensus about the indication for rehabilitation, as the treatment must be based on the individual characteristics of each patient. Copyright © 2018 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Implant-retained maxillary overdentures.
Eckert, Steven E; Carr, Alan B
2004-07-01
Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.
Use of mini dental implants in ectodermal dysplasia children: follow-up of three cases.
Sfeir, E; Nassif, N; Moukarzel, C
2014-07-01
Ectodermal dysplasia is a hereditary genodermatosis characterised by a congenital defect of ectodermal structures, causing tooth malformations and anomalies. Implantology has become accepted in these subjects. However cases are often complicated by a reduction in the size of the alveolar process, making the insertion of conventional implants difficult without bone grafting. The reduced diameter of mini-implants and their ease of insertion provide an interesting solution in supporting removable or fixed prosthesis. The purpose of this paper is to report the follow-up of three cases of children (11-12 year- old) with ectodermal dysplasia in which mini-implants were used to support the prostheses. In the first case, two mini-implants were inserted into the anterior part of the mandible for stabilising a removable denture (2 years follow-up). In the other two cases, mini- implants were inserted in the maxilla and mandible to replace missing front teeth with fixed prostheses. Patients were called for follow- up every 6 months: in the sencod case follow-up lasted 4 years in the mandible and 2 years in the maxilla; in the third case, 2 years in the maxilla and 1 year in the mandible. The use of mini-implants in children with ectodermal dysplasia can enhance aesthetics, and functional and psychosocial development.
Rehabilitation of a missing ear with an implant retained auricular prosthesis
Guttal, Satyabodh Sheshraj; Shanbhag, Shruti; Kulkarni, Sudhindra S.; Thakur, Srinath L.
2015-01-01
Burns can leave a patient with a severely debilitating disability even after treatment. The objectives of burn rehabilitation are to minimize the adverse effects caused by the injury while rehabilitating the patient's physical and psychological well-being, maximizing social integration. Long-term success of maxillofacial prostheses mainly depends on the retention. Extra oral implant retained prostheses have proved to be a predictable treatment option for maxillofacial rehabilitation. Replacement of a severely deformed external ear with burned tissues may be satisfactorily accomplished by a cosmetic prosthesis anchored by implants integrated in the skull. The use of such implants is now a well-recognized method for creating a stable result in maxillofacial rehabilitation. This case report describes a safe, simple and economical method for the rehabilitation of a patient with missing right auricle using an implant supported silicone prosthesis. The implant was placed in the mastoid region of the temporal bone. Reconstruction of the ear was done with auricular silicone prosthesis, retained using magnets incorporated in an autopolymerizing resin shim to decrease the weight of the prosthesis on a single implant. This method eliminates the need of tedious laboratory procedures and exact casting and fitting requirements of a metal substructure while minimizing the overall weight and cost of the prosthesis while maintaining adequate support, esthetics and retention of the prosthesis. PMID:26929490
Gebert, A; Peters, J; Bishop, N E; Westphal, F; Morlock, M M
2009-01-01
Primary stability is essential to the success of uncemented prostheses. It is strongly influenced by implantation technique, implant design and bone quality. The goal of this study was to investigate the effect of press-fit parameters on the primary stability of uncemented femoral head resurfacing prostheses. An in vitro study with human specimens and prototype implants (nominal radial interference 170 and 420 microm) was used to investigate the effect of interference on primary stability. A finite element model was used to assess the influence of interference, friction between implant and bone, and bone quality. Primary stability was represented by the torque capacity of the implant. The model predicted increasing stability with actual interference, bone quality and friction coefficient; plastic deformation of the bone began at interferences of less than 100 microm. Experimentally, however, stability was not related to interference. This may be due to abrasion or the collapse of trabecular bone structures at higher interferences, which could not be captured by the model. High nominal interferences as tested experimentally appear unlikely to result in improved stability clinically. An implantation force of about 2,500 N was estimated to be sufficient to achieve a torque capacity of about 30 N m with a small interference (70 microm).
Alzarea, Bader K
2016-04-01
Peri-implant tissue health is a requisite for success of dental implant therapy. Plaque accumulation leads to initiation of gingivitis around natural teeth and peri-implantitis around dental implants. Peri-implantitis around dental implants may result in implant placement failure. For obtaining long-term success, timely assessment of dental implant site is mandatory. To assess and evaluate Quality of Life (OHRQoL) of individuals with dental implants using the Oral Health Impact Profile (OHIP-14). Total 92 patients were evaluated for assessment of the health of peri-implant tissues by recording, Plaque Index (PI), Probing Pocket Depth (PD), Bleeding On Probing (BOP) and Probing Attachment Level (PAL) as compared to contra-lateral natural teeth (control). In the same patients Quality of Life Assessment was done by utilizing Oral Health Impact Profile Index (OHIP-14). The mean plaque index around natural teeth was more compared to implants and it was statistically significant. Other three dimensions mean bleeding on probing; mean probing attachment level and mean pocket depth around both natural teeth and implant surfaces was found to be not statistically significant. OHIP-14 revealed that patients with dental implants were satisfied with their Oral Health-Related Quality of Life (OHRQoL). Similar inflammatory conditions are present around both natural teeth and implant prostheses as suggested by results of mean plaque index, mean bleeding on probing, mean pocket depth and mean probing attachment level, hence reinforcing the periodontal health maintenance both prior to and after incorporation of dental implants. Influence of implant prostheses on patient's oral health related quality of life (as depicted by OHIP-14) and patients' perceptions and expectations may guide the clinician in providing the best implant services.
Economic implications of implant selection.
DeFronzo, D J; Landsman, A S; Ghareeb, J A
1995-07-01
Numerous types of implantable biomaterials are available for a variety of applications. Although much has been written about the physical properties or biocompatibility issues, very few papers have focused on the economic feasibility of these materials. This article assesses financial factors associated with first metatarsophalangeal total joint prostheses.
A Novel Percutaneous Electrode Implant for Improving Robustness in Advanced Myoelectric Control
Hahne, Janne M.; Farina, Dario; Jiang, Ning; Liebetanz, David
2016-01-01
Despite several decades of research, electrically powered hand and arm prostheses are still controlled with very simple algorithms that process the surface electromyogram (EMG) of remnant muscles to achieve control of one prosthetic function at a time. More advanced machine learning methods have shown promising results under laboratory conditions. However, limited robustness has largely prevented the transfer of these laboratory advances to clinical applications. In this paper, we introduce a novel percutaneous EMG electrode to be implanted chronically with the aim of improving the reliability of EMG detection in myoelectric control. The proposed electrode requires a minimally invasive procedure for its implantation, similar to a cosmetic micro-dermal implant. Moreover, being percutaneous, it does not require power and data telemetry modules. Four of these electrodes were chronically implanted in the forearm of an able-bodied human volunteer for testing their characteristics. The implants showed significantly lower impedance and greater robustness against mechanical interference than traditional surface EMG electrodes used for myoelectric control. Moreover, the EMG signals detected by the proposed systems allowed more stable control performance across sessions in different days than that achieved with classic EMG electrodes. In conclusion, the proposed implants may be a promising interface for clinically available prostheses. PMID:27065783
First-in-Human Trial of a Novel Suprachoroidal Retinal Prosthesis
Ayton, Lauren N.; Blamey, Peter J.; Guymer, Robyn H.; Luu, Chi D.; Nayagam, David A. X.; Sinclair, Nicholas C.; Shivdasani, Mohit N.; Yeoh, Jonathan; McCombe, Mark F.; Briggs, Robert J.; Opie, Nicholas L.; Villalobos, Joel; Dimitrov, Peter N.; Varsamidis, Mary; Petoe, Matthew A.; McCarthy, Chris D.; Walker, Janine G.; Barnes, Nick; Burkitt, Anthony N.; Williams, Chris E.; Shepherd, Robert K.; Allen, Penelope J.
2014-01-01
Retinal visual prostheses (“bionic eyes”) have the potential to restore vision to blind or profoundly vision-impaired patients. The medical bionic technology used to design, manufacture and implant such prostheses is still in its relative infancy, with various technologies and surgical approaches being evaluated. We hypothesised that a suprachoroidal implant location (between the sclera and choroid of the eye) would provide significant surgical and safety benefits for patients, allowing them to maintain preoperative residual vision as well as gaining prosthetic vision input from the device. This report details the first-in-human Phase 1 trial to investigate the use of retinal implants in the suprachoroidal space in three human subjects with end-stage retinitis pigmentosa. The success of the suprachoroidal surgical approach and its associated safety benefits, coupled with twelve-month post-operative efficacy data, holds promise for the field of vision restoration. Trial Registration Clinicaltrials.gov NCT01603576 PMID:25521292
Treatment planning: implant-supported partial overdentures.
Chee, Winston W L
2005-04-01
When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the implant-supported overdenture has several advantages, some in common with a removable partial denture.
Duan, Yonghong; Liu, Lie; Wang, Ling; Guo, Fei; Li, Haoping; Shi, Lei; Li, Mao; Yin, Dayu; Jiang, Chi; Zhu, Qingsheng
2012-03-01
Use of Ta biomaterials in medicine started in the middle of the last century. The good biocompatibility and chemical stability, and the unique physical characteristics of Ta metal have resulted in many possible developments of Ta biomaterials. In this study, histopathological observation, histomorphometric analysis, scanning electron microscope (SEM) observation, energy-dispersive X-ray spectroscopy (EDX) analysis, biomechanical testing, and examination of the coating's mechanical strength have been used to evaluate the value of clinical application of Ta-coated prostheses prepared by a plasma-spraying process. Histopathological observation has demonstrated that the periprosthetic new bone tissues tightly and stably adhere to the Ta coating after the implantation, with no signs of loosening. Early after implantation, there is no significant difference in periprosthetic bone volume and ultimate shear strength between Ta-coated and Ti-coated prostheses (P > 0.05). EDX analysis suggests that the ultimate shear stress does not damage Ta coating. Mechanical strength testing shows that the adhesive strength and Vicker's surface hardness (HV) of the Ta coating are significantly higher than those of the Ti coating (P < 0.01). Ta coating has good stability and bone biocompatibility; the extraordinary physical characteristics of Ta coating have great significance in maintaining prosthetic stability and surface porosity after implantation.
Berretin-Felix, Giédre; Nary, Hugo; Padovani, Carlos Roberto; Trindade, Alceu Sergio; Machado, Wellington Monteiro
2008-01-01
This study evaluated the effect of implant-supported oral rehabilitation in the mandible on the electromyographic activity during mastication and swallowing in edentulous elderly individuals. Fifteen patients aged more than 60 years were evaluated, being 10 females and 5 males. All patients were edentulous, wore removable complete dentures on both dental arches, and had the mandibular dentures replaced by implant-supported prostheses. All patients were submitted to electromyographic evaluation of the masseter, superior orbicularis oris muscles, and the submental muscles, before surgery and 3, 6 and 18 months postoperatively, using foods of different textures. The results obtained at the different periods were analyzed statistically by Kruskal-Wallis non-parametric test. Statistical analysis showed that only the masseter muscle had a significant loss in electromyographic activity (p<0.001), with a tendency of similar response for the submental muscles. Moreover, there was an increase in the activity of the orbicularis oris muscle during rubber chewing after treatment, yet without statistically significant difference. Mandibular fixed implant-supported prostheses in elderly individuals revealed a decrease in electromyographic amplitude for the masseter muscles during swallowing, which may indicate adaptation to new conditions of stability provided by fixation of the complete denture in the mandibular arch. PMID:19089202
Jeong, Jin-Seok; Chang, Moontaek
2015-12-01
Food impaction and periodontal/peri-implant tissue conditions were evaluated in relation to the embrasure dimensions between implant-supported fixed dental prostheses (FDPs) and adjacent teeth. A total of 215 embrasures of 150 FDPs in 100 patients (55 males and 45 females, aged 27 to 83 years; mean age: 56 years) were included in the study. Clinical assessments of the periodontal/peri-implant mucosal conditions, radiographic assessments of embrasure dimensions, and overall patient satisfaction were used as explanatory variables for the food impaction and periodontal/peri-implant tissue conditions adjacent to implant-supported FDPs in the generalized estimating equation (GEE) analysis. Food impaction was reported in 96 (44.7%) of 215 embrasures between implant-supported FDPs and adjacent teeth. Food impaction was reported more frequently in the embrasures with proximal contact loss than in those with tight contact (P = 0.009). Overall patient satisfaction was influenced negatively by food impaction in the proximal embrasures (P = 0.01). Among embrasure dimensions, only the embrasure surface area (ESA) significantly influenced food impaction (P = 0.03). Significant influences of various embrasure dimensions on the periodontal/peri-implant mucosal conditions and bone level at the implant were found in the univariate and multivariate GEE analyses. Food impaction between implant-supported FDPs and adjacent teeth occurred more frequently when proximal contact was lost and ESA increased. Food impaction negatively affected overall patient satisfaction. Embrasure dimensions influenced the periodontal/peri-implant mucosal conditions and bone level at the implant.
The development of artificial organs and prostheses worldwide and in the Ottoman Empire.
Birdane, Leman; Cingi, Cemal; Elçioğlu, Ömür; Muluk, Nuray Bayar
2016-08-01
An artificial organ or prosthesis is a man-made device that is implanted or integrated into a human to replace a natural organ. There were many historical steps in the development of artificial organs and prostheses. New surgical techniques, the development of prosthetic materials and the creative ideas of engineers led to progress in this field. © The European Society of Cardiology 2014.
MRI information for commonly used otologic implants: review and update.
Azadarmaki, Roya; Tubbs, Rhonda; Chen, Douglas A; Shellock, Frank G
2014-04-01
To review information on magnetic resonance imaging (MRI) issues for commonly used otologic implants. Manufacturing companies, National Library of Medicine's online database, and an additional online database (www.MRIsafety.com). A literature review of the National Library of Medicine's online database with focus on MRI issues for otologic implants was performed. The MRI information on implants provided by manufacturers was reviewed. Baha and Ponto Pro osseointegrated implants' abutment and fixture and the implanted magnet of the Sophono Alpha 1 and 2 abutment-free systems are approved for 3-Tesla magnetic resonance (MR) systems. The external processors of these devices are MR Unsafe. Of the implants tested, middle ear ossicular prostheses, including stapes prostheses, except for the 1987 McGee prosthesis, are MR Conditional for 1.5-Tesla (and many are approved for 3-Tesla) MR systems. Cochlear implants with removable magnets are approved for patients undergoing MRI at 1.5 Tesla after magnet removal. The MED-EL PULSAR, SONATA, CONCERT, and CONCERT PIN cochlear implants can be used in patients undergoing MRI at 1.5 Tesla with application of a protective bandage. The MED-EL COMBI 40+ can be used in 0.2-Tesla MR systems. Implants made from nonmagnetic and nonconducting materials are MR Safe. Knowledge of MRI guidelines for commonly used otologic implants is important. Guidelines on MRI issues approved by the US Food and Drug Administration are not always the same compared with other parts of the world. This monograph provides a current reference for physicians on MRI issues for commonly used otologic implants.
Burchard, Rene; Braas, Sabrina; Soost, Christian; Graw, Jan Adriaan; Schmitt, Jan
2017-08-07
The main objective of every new development in total hip arthroplasty (THA) is the longest possible survival of the implant. Periprosthetic stress shielding is a scientifically proven phenomenon which leads to inadvertent bone loss. So far, many studies have analysed whether implanting different hip stem prostheses result in significant preservation of bone stock. The aim of this preclinical study was to investigate design-depended differences of the stress shielding effect after implantation of a selection of short-stem THA-prostheses that are currently available. Based on computerised tomography (CT), a finite elements (FE) model was generated and a virtual THA was performed with different stem designs of the implant. Stems were chosen by osteotomy level at the femoral neck (collum, partial collum, trochanter sparing, trochanter harming). Analyses were performed with previously validated FE models to identify changes in the strain energy density (SED). In the trochanteric region, only the collum-type stem demonstrated a biomechanical behaviour similar to the native femur. In contrast, no difference in biomechanical behaviour was found between partial collum, trochanter harming and trochanter sparing models. All of the short stem-prostheses showed lower stress-shielding than a standard stem. Based on the results of this study, we cannot confirm that the design of current short stem THA-implants leads to a different stress shielding effect with regard to the level of osteotomy. Somehow unexpected, we found a bone stock protection in metadiaphyseal bone by simulating a more distal approach for osteotomy. Further clinical and biomechanical research including long-term results is needed to understand the influence of short-stem THA on bone remodelling and to find the optimal stem-design for a reduction of the stress shielding effect.
The current use of patient-centered/reported outcomes in implant dentistry: a systematic review.
De Bruyn, Hugo; Raes, Stefanie; Matthys, Carine; Cosyn, Jan
2015-09-01
To provide an update on the use of Patient-Reported Outcome Measures (PROMs) in the field of implant dentistry (1); to compare PROMs for prostheses supported by one or more implants to alternative treatment options or a healthy dentition (2). The dental literature was searched on PubMed until December 31, 2014, using a general search algorithm. An overall quantitative analysis was performed, and a qualitative appraisal was made on the output of the last 6 years. Per type of edentulism and prosthetic treatment, the general search algorithm was refined in order to select controlled studies comparing PROMs for prostheses supported by one or more implants to alternative treatment options or a healthy dentition. With nearly half of the output (300 of 635) published in the last 6 years, there is a growing interest in PROMs by the scientific community. When scrutinizing the 300 most recent publications, only 84 controlled studies could be identified among which 38 RCTs and 31 cohort studies. An "ad hoc" approach is commonly employed using non-standardized questions and different scoring methods, which may compromise validity and reliability. Overall, 39 eligible papers related to fully edentulous patients treated with an implant overdenture (IOD) and 9 to fully edentulous patients treated with a fixed implant prosthesis (FIP). There is plenty of evidence from well-controlled studies showing that fully edentulous patients in the mandible experience higher satisfaction with an IOD when compared to a conventional denture (CD). This may not hold true for fully edentulous patients in the maxilla. In general, fully edentulous patients seem to opt for a fixed or removable rehabilitation on implants for specific reasons. Data pertaining to partially edentulous patients were limited (FIP: n = 6; single implants: n = 16). In these patients, the timing of implant placement does not seem to affect patient satisfaction. Patients seem to prefer straightforward implant surgery over complex surgery that includes bone grafting. There is an urgent need for standardized reporting of PROMs in the field of implant dentistry. Fully edentulous patients in the mandible experience higher satisfaction with an IOD when compared to a CD. All other types of prostheses have been underexposed to research. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Longoni, Salvatore; Sartori, Matteo; Davide, Roberto
2004-06-01
An important aim of implant-supported prostheses is to achieve a passive fit of the framework with the abutments to limit the amount of stress transfer to the bone-implant interface. An efficient and standardized technique is proposed. A definitive screw-retained, implant-supported complete denture was fabricated for an immediately loaded provisional screw-retained implant-supported complete denture. Precise fit was achieved by the use of industrial titanium components and the passivity, by an intraoral luting sequence and laser welding.
Optimization of dental implantation
NASA Astrophysics Data System (ADS)
Dol, Aleksandr V.; Ivanov, Dmitriy V.
2017-02-01
Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.
Grigoriadis, Joannis; Trulsson, Mats; Svensson, Krister G
2016-04-01
Appropriate sensory information from periodontal mechanoreceptors (PMRs) is important for optimizing the positioning of food and adjustment of force vectors during precision biting. This study was designed to describe motor behavior during the first cycle of a natural chewing task and to evaluate the role of such sensory input in this behavior. While 10 subjects with natural dentition, 11 with bimaxillary fixed tooth-supported prostheses (TSP) and 10 with bimaxillary fixed implant-supported prostheses (ISP) (mean age 69 [range 61-83]) chewed a total of five hazelnuts, their vertical and lateral jaw movements were recorded. Data obtained during the first chewing cycle of each hazelnut were analyzed. The amplitude of vertical and lateral mandibular movement and duration of jaw opening did not differ between the groups, indicating similar behavior during this part of the chewing cycle. However, only 30% of the subjects in the natural dentate group, but 82% of those in the TSP and 70% in the ISP group exhibited slippage of the hazelnut during jaw closure in at least one of five trials. The TSP and ISP groups also exhibited more irregular and narrower patterns of motion (total lateral/vertical movement = 0.15 and 0.19, respectively, compared to 0.27 for the natural group). Subjects with fixed tooth- or implant-supported prostheses in both jaws show altered behavior, including inadequate control of the hazelnut, during the first chewing cycle. We propose that these differences are due to impairment or absence of sensory signaling from PMRs in these individuals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Speech Rate Normalization and Phonemic Boundary Perception in Cochlear-Implant Users
ERIC Educational Resources Information Center
Jaekel, Brittany N.; Newman, Rochelle S.; Goupell, Matthew J.
2017-01-01
Purpose: Normal-hearing (NH) listeners rate normalize, temporarily remapping phonemic category boundaries to account for a talker's speech rate. It is unknown if adults who use auditory prostheses called cochlear implants (CI) can rate normalize, as CIs transmit degraded speech signals to the auditory nerve. Ineffective adjustment to rate…
Alzoubi, Fawaz; Bedrossian, Edmond; Wong, Allen; Farrell, Douglas; Park, Chan; Indresano, Thomas
To assess outcomes of treating completely edentulous patients with a fixed implant-supported profile prosthesis utilizing a graftless approach for the maxilla and for the mandible, with emphasis on clinically related outcomes, specifically implant and prosthesis survival. This was a retrospective study with the following inclusion criteria: completely edentulous patients rehabilitated with a fixed implant-supported profile denture utilizing a graftless approach. Patients fulfilling the inclusion criteria were asked to participate in the study during their follow-up visits, and hence a consecutive sampling strategy was used. Data regarding implant and prosthesis cumulative survival rates (CSRs) were gathered and calculated. Thirty-four patients were identified with a total of 220 implants placed. An overall CSR of 98.2% was recorded with an observation of up to 10 years. For tilted, axial, and zygomatic implants, CSRs of 96.9%, 98.0%, and 100%, respectively, were observed for up to 10 years. For provisional prostheses, CSRs of 92.3% at 1 year, and 84.6% at 2 years were observed. For final prostheses, a CSR of 93.8% was observed at 10 years. The results suggest that treating completely edentulous patients with a fixed profile prosthesis utilizing a graftless approach in the maxilla and the mandible can be a reliable treatment option.
Verma, Rohini; Joda, Tim; Brägger, Urs; Wittneben, Julia-Gabriela
2013-01-01
The objective of this review was to systematically screen the literature for data related to the survival and complication rates observed with dental or implant double crown abutments and removable prostheses under functional loading for at least 3 years. A systematic review of the dental literature from January 1966 to December 2009 was performed in electronic databases (PubMed and Embase) as well as by an extensive hand search to investigate the clinical outcomes of double crown reconstructions. From the total of 2412 titles retrieved from the search, 65 were selected for full-text review. Subsequently, 17 papers were included for data extraction. An estimation of the cumulative survival and complication rates was not feasible due to the lack of detailed information. Tooth survival rates for telescopic abutment teeth ranged from 82.5% to 96.5% after an observation period of 3.4 to 6 years, and for tooth-supported double crown retained dentures from 66.7% to 98.6% after an observation period of 6 to 10 years. The survival rates of implants were between 97.9% and 100% and for telescopic-retained removable dental prostheses with two mandibular implants, 100% after 3.0 and 10.4 years. The major biological complications affecting the tooth abutments were gingival inflammation, periodontal disease, and caries. The most frequent technical complications were loss of cementation and loss of facings. The main findings of this review are: (I) double crown tooth abutments and dentures demonstrated a wide range of survival rates. (II) Implant-supported mandibular overdentures demonstrated a favorable long-term prognosis. (III) A greater need for prosthetic maintenance is required for both tooth-supported and implant-supported reconstructions. (IV) Future areas of research would involve designing appropriate longitudinal studies for comparisons of survival and complication rates of different reconstruction designs. © 2012 by the American College of Prosthodontists.
Pacheco Usmayo, A; Torregrosa Andrés, A; Flores Méndez, J; Luján Marco, S; Rogel Bertó, R
To describe the types of penile prostheses and their components, to review the appropriate magnetic resonance imaging (MRI) acquisition protocol, and to describe the normal imaging findings and possible complications in patients with inflatable penile implants. Three-piece inflatable penile prostheses are the last link in the treatment chain for erectile dysfunction. They can develop complications, which are classified as non-infectious related to the surgical technique, infectious, or due to mechanical failure of the device. MRI is the most appropriate imaging technique for the postsurgical evaluation of penile prostheses. Images are acquired in three planes using sequences with high spatial resolution, first with the prosthesis at rest and then with the prosthesis activated. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Biomechanical study of the tibia in knee replacement revision.
Quílez, M P; Pérez, M A; Seral-García, B
2015-01-01
The best management of severe bone defects following total knee replacement is still controversial. Metal augments, tantalum cones and porous tibial sleeves could help the surgeon to manage any type of bone loss, providing a stable and durable knee joint reconstruction. Five different types of prostheses have been analysed: one prosthesis with straight stem; two prostheses with offset stem, with and without supplement, and two prostheses with sleeves, with and without stem. The purpose of this study is to report a finite element study of revision knee tibial implants. The main objective was to analyse the tibial bone density changes and Von Misses tension changes following different tibial implant designs. In all cases, the bone density decreases in the proximal epiphysis and medullary channels, with a bone density increase also being predicted in the diaphysis and at the bone around the stems tips. The highest value of Von Misses stress has been obtained for the straight tibial stem, and the lowest for the stemless metaphyseal sleeves prosthesis. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.
Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G
2012-06-01
We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p < 0.05). In axial rotation, only the 3°/3° design reduced ROM (p < 0.05). Eleven-degree lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p < 0.05). Overall, L5-S1 range of motion was not markedly influenced by lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.
Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation.
Lumetti, S; Ghiacci, G; Macaluso, G M; Amore, M; Galli, C; Calciolari, E; Manfredi, E
2016-01-01
Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.
Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation
Amore, M.
2016-01-01
Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation. PMID:28050290
Byun, Soo-Jung; Heo, Seok-Mo; Ahn, Seung-Geun; Chang, Moontaek
2015-06-01
The aim was to analyze influential factors and effects of proximal contact loss between implant-supported fixed dental prostheses (FDP) and adjacent teeth. Ninety-four subjects treated with 135 FDPs supported by 188 implants were included. Degree of proximal contact tightness, food impaction, and periodontal/peri-implant tissue conditions were assessed in 191 proximal embrasures between implant-supported FDPs and adjacent teeth. Potential factors influencing proximal contact loss were estimated with the generalized estimation equation (GEE) procedure. Thirty-four percent of the proximal embrasures between implant-supported FDPs and teeth lost a proximal contact. The proximal contact loss rate continuously increased over the follow-up periods. A longer follow-up period, splinted implants, and mesial aspect of proximal contact were significant factors influencing the proximal contact loss in the univariate GEE analysis, whereas a longer follow-up period was the only significant factor in the multivariate GEE analysis. Food impaction was more frequently reported in the proximal contact loss group than the proximal contact group (odds ratio: 2.2). However, the proximal contact loss did not appear to affect the periodontal/peri-implant tissue conditions. Proximal contact loss between implant-supported FDPs and teeth occurred frequently and increased continuously over the follow-up period. The proximal contact loss significantly affected food impaction, but not the periodontal/peri-implant tissue conditions. Proximal contact loss should be carefully monitored during follow-up examinations in relation to food impaction. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Radi, Iman Abd-Elwahab
2016-03-01
Effect of cantilevers for implant-supported prostheses on marginal bone loss and prosthetic complications: systematic review and meta-analysis. Torrecillas-Martinez L, Monje A, Lin G, Suarez F, Ortega-Oller I, Galindo-Moreno P, Wang H. Int J Oral Maxillofac Implants 2014;29(6):1315-21. Not reported Systematic review and meta-analysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Auditory Midbrain Implant: Research and Development Towards a Second Clinical Trial
Lim, Hubert H.; Lenarz, Thomas
2015-01-01
The cochlear implant is considered one of the most successful neural prostheses to date, which was made possible by visionaries who continued to develop the cochlear implant through multiple technological and clinical challenges. However, patients without a functional auditory nerve or implantable cochlea cannot benefit from a cochlear implant. The focus of the paper is to review the development and translation of a new type of central auditory prosthesis for this group of patients, which is known as the auditory midbrain implant (AMI) and is designed for electrical stimulation within the inferior colliculus. The rationale and results for the first AMI clinical study using a multi-site single-shank array will be presented initially. Although the AMI has achieved encouraging results in terms of safety and improvements in lip-reading capabilities and environmental awareness, it has not yet provided sufficient speech perception. Animal and human data will then be presented to show that a two-shank AMI array can potentially improve hearing performance by targeting specific neurons of the inferior colliculus. Modifications to the AMI array design, stimulation strategy, and surgical approach have been made that are expected to improve hearing performance in the patients implanted with a two-shank array in an upcoming clinical trial funded by the National Institutes of Health. Positive outcomes from this clinical trial will motivate new efforts and developments toward improving central auditory prostheses for those who cannot sufficiently benefit from cochlear implants. PMID:25613994
Razaghi, Reza; Biglari, Hasan; Karimi, Alireza
2017-05-01
The long-term application of dental prostheses inside the bone has a narrow relation to its biomechanical performance. Chewing is the most complicated function of a dental implant as it implements different forces to the implant at various directions. Therefore, a suitable holistic modelling of the jaw bone, implant, food, muscles, and their forces would be deemed significant to figure out the durability as well as functionality of a dental implant while chewing. So far, two approaches have been proposed to employ the muscle forces into the Finite Element (FE) models, i.e. Muscle Equivalent Force (MEF) and trajectory. This study aimed at propounding a new three-dimensional dynamic FE model based on two muscle forces modelling approaches in order to investigate the stresses and deformations in the dental prosthesis as well as maxillary bone during the time of chewing a cornflakes bio. The results revealed that both contact and the maximum von Mises stress in the implant and bones for trajectory approach considerably exceed those of the MEF. The maximum stresses, moreover, are located around the neck of implant which should be both clinically and structurally strong enough to functionally maintain the bone-implant interface. In addition, a higher displacement due to compressive load is observed for the implant head in trajectory approach. The results suggest the benefits provided by trajectory approach since MEF approach would significantly underestimate the stresses and deformations in both the dental prosthesis and bones.
Gherlone, Enrico F.; Rapanelli, Andrea; Crespi, Roberto; Gastaldi, Giorgio
2018-01-01
Objectives The aim of this clinical study was to evaluate a new type of prefabricated bar system, supported by axial and tilted implants at 5-year follow-up. Materials and Methods Twenty-nine consecutive participants (19 females, 10 males) (mean age 61.4 years), edentulous in one or both jaws, with severe atrophy of the posterior regions, were treated according to the All-on-four® protocol with immediately loaded axial (64) and tilted (64) implants supporting complete-arch screw-retained prostheses (12 maxillary, 20 mandibular) featuring a prefabricated bar as framework. Follow-up visits were performed at 3, 6, 12, 24, 48, and 60 months after implant insertion. Radiographic assessments were made using panoramic radiographs obtained immediately after surgery and at each follow-up visit. Bone level measurements around the axial and tilted implants were compared by means of the Student's t-test. Results One axial implant failed in the lower jaw and did not compromise prosthetic function. The 60-month overall implant survival rate was 100% for axially positioned implants and 98.44% for tilted implants. The implant survival rates were 100% in the maxilla and 98.75% in the mandible. None of the 32 fixed prostheses were lost during the observation period, representing a prosthetic survival rate of 100%. No statistically significant differences (P > 0.05) in marginal bone loss between tilted and axial implants were detected in either jaw over time. Conclusions The use of the evaluated prefabricated bar for immediately loaded implants placed according to the All-on-four concept may significantly reduce implant failures; however, more long-term prospective clinical trials are needed to affirm the effectiveness of the surgical-prosthetic protocol. PMID:29682552
[Aftercare for durability and profitability of single-unit and multi-unit fixed dental prostheses].
de Baat, C; van Loveren, C; van der Maarel-Wierink, C D; Witter, D J; Creugers, N H J
2013-01-01
An important aim ofa treatment with single-unit and multi-unit fixed dental prostheses is a durable and profitable treatment outcome. That requires aftercare, too. First, the frequency of routine oral examinations should be assessed, using an individual risk profile. The objectives of the routine oral examinations are the prevention and, when necessary, the treatment of pathological conditions and complications. With regard to prevention, attention should be paid to information and instruction, oral biofilm and calculus, non-functional activities, hard tooth tissues, periodontal and peri-implant tissues, and saliva. Subsequently, it can be determined whether the intended durability and profitability have been achieved or can still be achieved, whether or not through indicated adjustments. Special attention should be paid to endodontically treated teeth. Restorative, repair or replacement treatments may be indicated in case ofcomplications, such as loose single- or multi-unitfixed dental prosthesis, fracture of a fixed dental prosthesis unit, lost tooth pulp vitality, tooth root fracture, and implant or implant abutment problems.
Manufacturing implant supported auricular prostheses by rapid prototyping techniques.
Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent
2011-08-01
Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.
Coordes, Annekatrin; Jahreiss, Linda; Schönfeld, Uwe; Lenarz, Minoo
2017-02-01
After stapes surgery, patients with mixed or moderate hearing loss have limited possibilities for hearing improvement. We are reporting on a patient who underwent stapedotomy bilaterally 20 years ago and had sensorineural and mixed hearing loss. Recurrent otitis externa prevented the use of hearing aids. This patient was treated bilaterally with the Vibrant Soundbridge (Med-El, Innsbruck, Austria) successively. The Schuknecht piston stapes prostheses remained in situ. The Floating Mass Transducer (FMT; Med-El) was coupled to the round window (RW) and provided good acoustic reinforcement bilaterally. In conclusion, for patients with otosclerosis and stapes surgery, the FMT-RW coupling (Bess AG, Berlin, DE) is a safe procedure with good acoustic amplification. Laryngoscope, 2016 127:500-503, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Heo, Man Seung; Moon, Hyun Seok; Kim, Hee Chan; Park, Hyung Woo; Lim, Young Hoon; Paek, Sun Ha
2015-03-01
The purpose of this study to develop new deep-brain stimulation system for long-term use in animals, in order to develop a variety of neural prostheses. Our system has two distinguished features, which are the fully implanted system having wearable wireless power transfer and ability to change the parameter of stimulus parameter. It is useful for obtaining a variety of data from a long-term experiment. To validate our system, we performed pre-clinical test in Parkinson's disease-rat models for 4 weeks. Through the in vivo test, we observed the possibility of not only long-term implantation and stability, but also free movement of animals. We confirmed that the electrical stimulation neither caused any side effect nor damaged the electrodes. We proved possibility of our system to conduct the long-term pre-clinical test in variety of parameter, which is available for development of neural prostheses.
Reflections on the present and future of upper limb prostheses.
Farina, Dario; Amsüss, Sebastian
2016-01-01
Despite progress in research and media attention on active upper limb prostheses, presently the most common commercial upper limb prosthetic devices are not fundamentally different from solutions offered almost one century ago. Limited information transfer for both control and sensory-motor integration and challenges in socket technology have been major obstacles. By analysing the present state-of-the-art and academic achievements, we provide our opinion on the future of upper limb prostheses. We believe that surgical procedures for muscle reinnervation and osseointegration will become increasingly clinically relevant; muscle electrical signals will remain the main clinical means for prosthetic control; and chronic electrode implants, first in muscles (control), then in nerves (sensory feedback), will become viable clinical solutions. After decades of suspended clinically relevant progress, it is foreseeable that a new generation of upper limb prostheses will enter the market in the near future based on such advances, thereby offering substantial clinical benefit for patients.
Takaba, Masayuki; Tanaka, Shinpei; Ishiura, Yuichi; Baba, Kazuyoshi
2013-07-01
Recently, fixed dental prostheses (FDPs) with a hybrid structure of CAD/CAM porcelain crowns adhered to a CAD/CAM zirconia framework (PAZ) have been developed. The aim of this report was to describe the clinical application of a newly developed implant-supported FDP fabrication system, which uses PAZ, and to evaluate the outcome after a maximum application period of 36 months. Implants were placed in three patients with edentulous areas in either the maxilla or mandible. After the implant fixtures had successfully integrated with bone, gold-platinum alloy or zirconia custom abutments were first fabricated. Zirconia framework wax-up was performed on the custom abutments, and the CAD/CAM zirconia framework was prepared using the CAD/CAM system. Next, wax-up was performed on working models for porcelain crown fabrication, and CAD/CAM porcelain crowns were fabricated. The CAD/CAM zirconia frameworks and CAD/CAM porcelain crowns were bonded using adhesive resin cement, and the PAZ was cemented. Cementation of the implant superstructure improved the esthetics and masticatory efficiency in all patients. No undesirable outcomes, such as superstructure chipping, stomatognathic dysfunction, or periimplant bone resorption, were observed in any of the patients. PAZ may be a potential solution for ceramic-related clinical problems such as chipping and fracture and associated complicated repair procedures in implant-supported FDPs. © 2012 by the American College of Prosthodontists.
Titania nanotube arrays as potential interfaces for neurological prostheses
NASA Astrophysics Data System (ADS)
Sorkin, Jonathan Andrew
Neural prostheses can make a dramatic improvement for those suffering from visual and auditory, cognitive, and motor control disabilities, allowing them regained functionality by the use of stimulating or recording electrical signaling. However, the longevity of these devices is limited due to the neural tissue response to the implanted device. In response to the implant penetrating the blood brain barrier and causing trauma to the tissue, the body forms a to scar to isolate the implant in order to protect the nearby tissue. The scar tissue is a result of reactive gliosis and produces an insulated sheath, encapsulating the implant. The glial sheath limits the stimulating or recording capabilities of the implant, reducing its effectiveness over the long term. A favorable interaction with this tissue would be the direct adhesion of neurons onto the contacts of the implant, and the prevention of glial encapsulation. With direct neuronal adhesion the effectiveness and longevity of the device would be significantly improved. Titania nanotube arrays, fabricated using electrochemical anodization, provide a conductive architecture capable of altering cellular response. This work focuses on the fabrication of different titania nanotube array architectures to determine how their structures and properties influence the response of neural tissue, modeled using the C17.2 murine neural stem cell subclone, and if glial encapsulation can be reduced while neuronal adhesion is promoted.
New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations
Romero, Luis; Jiménez, Mariano; Espinosa, María del Mar; Domínguez, Manuel
2015-01-01
Aim This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. Method From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Results Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants. PMID:26696528
New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.
Romero, Luis; Jiménez, Mariano; Espinosa, María Del Mar; Domínguez, Manuel
2015-01-01
This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.
Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan
2015-07-01
The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p<0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p<0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Ostman, Pär-Olov; Hellman, Mats; Sennerby, Lars; Wennerberg, Ann
2008-05-01
During the last years, focus has been paid to implant treatment using immediate function protocols, and different approaches to provide patients with temporary constructions have been presented. Most of these techniques involve dental technicians producing the temporary construction, for example, rebuilding existing dentures, acrylic bridges, etc. The purpose of this prospective clinical study was to evaluate the clinical outcome of a chair-side technique of a cost-effective temporary prosthesis. Fixture survival rate and risk of temporary bridge failure were analyzed. Thirty-seven partially or totally edentate patients (18 female and 19 male; mean age: 66.7 years) treated with chair-side manufactured temporary restorations (QuickBridge, BIOMET 3i, Palm Beach, Fl, USA) for immediate loading have been evaluated. The prostheses extended from two unit bridges supported by two implants to full-arch construction supported by six implants. The temporary prostheses were monitored from the day of surgery and delivery to the time of replacement with a permanent prosthetic construction 3 to 6 months later. No implants were lost during the observation time. One (3%) temporary prosthesis fractured and additional two (6%) loosened during the follow-up time. The study indicated that the tested chair-side concept for manufacturing of temporary prosthesis for immediate loading of dental implants is a viable approach.
Park, Young-Jin; Cho, Sung-Am
2010-06-01
To evaluate the survival rate of implants placed in the maxillary tuberosity region using the fixed prosthesis in partially edentulous cases. Of implant-treated patients who visited Kyung Pook National University Hospital, 7 partially edentulous patients (2 male and 5 female; mean age, 52.3 years; range, approximately 43 to 65) were selected according to the following criteria: 1) less than 3-mm thickness alveolar bone reaming at the first molar area and 2) 1 to 2 fixture premolars, with the additional implant at the maxillary tuberosity region. For the control group, patients who had nontuberosity areas were selected. After 1 to 7 years, marginal bone level, fixture mobility, and radiolucency of tuberosity fixtures of the fixed prostheses were evaluated by digital panorama (Starpacs, Infinitt, Seoul, Korea). None of the fixtures of the tuberosity-installed implants for 1 to 7 years failed. The marginal bone level around the implants of the maxillary tuberosity 1 to 6 years (average 3.4 years) after the final prostheses was approximately 0.6 to 1.3 mm, with an average of 0.94 mm. The fixture installation at the maxillary tuberosity using the unilateral partially edentulous implant-fixed prosthesis would be a clinically acceptable treatment module. 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Zygoma implants in oral rehabilitation: A review of 28 cases
Agbara, Rowland; Goetze, Elizabeth; Koch, Felix; Wagner, Wilfred
2017-01-01
Background: The functional and esthetic rehabilitation of patients with atrophic maxilla or posterior maxillary defect is often challenging. The aim of this study was to determine patient demographics, indications, success rate, and complications following the use of zygoma implants. Materials and Methods: All patients who had zygoma implant placement in our clinic between 1998 and 2013 were retrospectively assessed for implant outcome. Data were analyzed using Statistical Package for the Social Sciences (SPSS) version 16 and Microsoft Excel 2007 test for significance (ρ) using Pearson's Chi-square (χ2) set at 0.05. Results: A total of 28 patients consisting of 22 females (78.6%) and 6 males (21.4%) were treated, and their age ranged from 41 years to 83 years with a mean age of 60.3 ± 10.6 years. The main indication for zygoma implant placement was atrophic maxilla 12 (42.9%). In the prosthetic rehabilitation of the patients, 2 had epithetic prostheses, and 2 had obturators while 18 patients had conventional removable dental prostheses. Four patients (14.3%) had perimplantitis and one implant was accidentally placed into the maxillary sinus. A cumulative success rate of 88.1% was obtained from this retrospective analysis. Conclusion: A cumulative success rate of 88.1% reported in this study is lower than the reports from other studies. The difference in success rates may be related to different criteria for assessment of zygoma implant success and to the difference in inclusion criteria and follow-up period. PMID:29238374
Zygoma implants in oral rehabilitation: A review of 28 cases.
Agbara, Rowland; Goetze, Elizabeth; Koch, Felix; Wagner, Wilfred
2017-01-01
The functional and esthetic rehabilitation of patients with atrophic maxilla or posterior maxillary defect is often challenging. The aim of this study was to determine patient demographics, indications, success rate, and complications following the use of zygoma implants. All patients who had zygoma implant placement in our clinic between 1998 and 2013 were retrospectively assessed for implant outcome. Data were analyzed using Statistical Package for the Social Sciences (SPSS) version 16 and Microsoft Excel 2007 test for significance (ρ) using Pearson's Chi-square (χ 2 ) set at 0.05. A total of 28 patients consisting of 22 females (78.6%) and 6 males (21.4%) were treated, and their age ranged from 41 years to 83 years with a mean age of 60.3 ± 10.6 years. The main indication for zygoma implant placement was atrophic maxilla 12 (42.9%). In the prosthetic rehabilitation of the patients, 2 had epithetic prostheses, and 2 had obturators while 18 patients had conventional removable dental prostheses. Four patients (14.3%) had perimplantitis and one implant was accidentally placed into the maxillary sinus. A cumulative success rate of 88.1% was obtained from this retrospective analysis. A cumulative success rate of 88.1% reported in this study is lower than the reports from other studies. The difference in success rates may be related to different criteria for assessment of zygoma implant success and to the difference in inclusion criteria and follow-up period.
Jauch, S Y; Huber, G; Hoenig, E; Baxmann, M; Grupp, T M; Morlock, M M
2011-06-03
Hip prostheses with a modular neck exhibit, compared to monobloc prostheses, an additional interface which bears the risk of fretting as well as corrosion. Failures at the neck adapter of modular prostheses have been observed for a number of different designs. It has been speculated that micromotions at the stem-neck interface were responsible for these implant failures. The purpose of this study was to investigate the influence of material combinations and assembly conditions on the magnitude of micromotions at the stem-neck interface during cyclic loading. Modular (n = 24) and monobloc (n = 3) hip prostheses of a similar design (Metha, Aesculap AG, Tuttlingen, Germany) were subjected to mechanical testing according to ISO 7206-4 (F(min) = 230N, F(max) = 2300N, f = 1Hz, n = 10,000 cycles). The neck adapters (Ti-6Al-4V or Co-Cr29-Mo alloy) were assembled with a clean or contaminated interface. The micromotion between stem and neck adapter was calculated at five reference points based on the measurements of the three eddy current sensors. The largest micromotions were observed at the lateral edge of the stem-neck taper connection, which is in accordance with the crack location of clinically failed prostheses. Titanium neck adapters showed significantly larger micromotions than cobalt-chromium neck adapters (p = 0.005). Contaminated interfaces also exhibited significantly larger micromotions (p < 0.001). Since excessive micromotions at the stem-neck interface might be involved in the process of implant failure, special care should be taken to clean the interface prior to assembly and titanium neck adapters with titanium stems should generally be used with caution. Copyright © 2011 Elsevier Ltd. All rights reserved.
The Poly Implant Prothèse breast prostheses scandal: Embodied risk and social suffering.
Greco, Cinzia
2015-12-01
This article examines the 2010 scandal surrounding the use and subsequent recall of adulterated Poly Implant Prothèse (PIP) silicone breast prostheses in France. It uses a mixed method approach that includes 12 interviews with French PIP prosthesis recipients, analyses of medical literature, policy documents of French and EU regulatory agencies, and an online forum for PIP recipients. These data are used to explain how the definition of "acceptable risk" in the silicone implants controversy of the 1990s in the US influenced the PIP scandal later on in France. Additionally, PIP recipients had an embodied experience of risk that clashed with the definition of risk used by authorities and some surgeons. The coverage of re-implantation was also defined at different policy levels, leading to variation in patients' suffering. The combination of fraud and lack of recognition from part of the medical system constitutes an example of social suffering for the patients involved. The PIP scandal is a useful case for analyzing the interconnection of embodied experience and professional and public policy definitions of medical risk through the concepts of moral economy and biological citizenship. Copyright © 2015 Elsevier Ltd. All rights reserved.
Implant retained auricular prosthesis with a modified hader bar: a case report.
Lovely, M; Dathan, Pradeep C; Gopal, Dinesh; George, Biji Thomas; Chandrasekharan Nair, K
2014-06-01
Auricular prostheses for defects of external ear are retained either by mechanical means or implants. All implant retained prostheses are retained by various means such as bar and clip, magnetic attachments or a combination of bar, clip and magnets. The commonest problem encountered with the bar and clip system is loosening of the clip after 3-4 months. When magnets are used as retaining component they tend to corrode over a period of time. So various alternative retention methods which possess good retentive qualities, ease of reparability and patient friendly were tried. In the present case a newly modified Hader bar design which can act as an additional retentive feature apart from the clip is employed to increase retention. The major advantages in the modified Hader bar system were that only two implants were employed, the additional loops in the Hader bar prevented micro movements and the retentive acrylic locks were easy to repair if broken. The modified Hader bar has anti-rotational slots which prevents the sliding or rotation of the prosthesis which gave new confidence to the patient who was otherwise worried of inadvertent displacement of the ear prosthesis while playing.
Cytocompatibility, cytotoxicity and genotoxicity analysis of dental implants
NASA Astrophysics Data System (ADS)
Reigosa, M.; Labarta, V.; Molinari, G.; Bernales, D.
2007-11-01
Several types of materials are frequently used for dental prostheses in dental medicine. Different treatments with titanium are the most used. The aim of the present study was to analyze by means of cytotoxicity and cytocompatibility techniques the capacity of dental implants to integrate to the bone tissue. Cultures of UMR 106 cell line derived from an osteosarcoma were used for bioassays mainly because they show many of the properties of osteoblasts. Dental implant samples provided by B&W company were compared with others of recognized trademarks. The first ones contain ASTM titanium (8348 GR2) with acid printing. Cytotoxicity was analyzed by means of lysosome activity, using the neutral red technique and alkaline phosphatase enzyme activity. Cell variability was determined by means of the acridine ethidium-orange bromide technique. One-way ANOVA and Bonferroni and Duncan post-ANOVA tests were used for the statistical analysis. The assays did not show significant differences among the dental implants analyzed. Our findings show that the dental prostheses studied present high biocompatibility, quantified by the bioassays performed. The techniques employed revealed that they can be a useful tool for the analysis of other materials for dental medicine use.
Singh, Ipsha; Nair, K Chandrasekharan; Shetty, Jayakar
2017-01-01
The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains). Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains). Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.
Gonzalez, Jorge; Triplett, Robert G
To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a low incidence was observed in this study. Acrylic denture teeth may represent the weakest link when restoring complete edentulism with a maxillary ZIRCAP and mandibular conventional hybrid prosthesis.
Method to improve passive fit of frameworks on implant-supported prostheses: An in vitro study.
Manzella, Carlo; Bignardi, Cristina; Burello, Valerio; Carossa, Stefano; Schierano, Gianmario
2016-07-01
The passivity of the superstructure to the abutments of implant-supported prostheses is necessary for implant-prosthesis success. Improvements are needed in the methods of verifying passivity. The purpose of this in vitro study was to evaluate an inexpensive, easy to make, and user-friendly device to verify the position of the implant abutment replicas of the definitive cast and to avoid framework misfit before fabrication. Eighty stone devices were constructed on a metal base for the in vitro tests. The horizontal, vertical, and angled positions of the implant replicas were created to simulate misfits. The devices were fitted on the abutment replicas, and their ability to identify misfits was evaluated. A statistical analysis was not indicated, because the probability of fracture of the stone devices was 0 or 1. Two mathematical models were built using computer-aided design software (SolidWorks Premium; Dassault Systèmes SolidWorks Corp), and the finite element method was used (Ansys; ANSYS Inc) to simulate the structural behavior of 2 implant configurations (4 and 6 implants). Horizontal misfits of 150 μm, vertical misfits of 50 μm, and angled misfits of 1 degree were detected during the in vitro tests. Different loads and bone quality in the mathematical models did not change stress in the prosthesis configurations on 4 or 6 implants in a relevant way. The fabricated device was easily able to detect the misfits in accordance with the defined parameters. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Does location of rotation center in artificial disc affect cervical biomechanics?
Mo, Zhongjun; Zhao, Yanbin; Du, Chengfei; Sun, Yu; Zhang, Ming; Fan, Yubo
2015-04-15
A 3-dimensional finite element investigation. To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Implantation of 5 prostheses was simulated at C5-C6 on the basis of a validated finite element cervical model (C3-C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implant interface. Cervical stability was extremely affected in extension and partially affected in flexion by total disc replacement. With the prostheses with mobile RC, cervical curvature was readjusted under a low follower load. The SA-V and BS-FS designs exhibited better performances in the entire segmental stiffness and in the stability of the operative level than the BS-MI and BS-FI designs in flexion. The 5 designs demonstrated varying advantages relative to the stress distribution in the facet cartilages and on the bone-implant interface. 5.
Ghanbarzadeh, Jalil; Dashti, Hossin; Karamad, Reza; Alikhasi, Marzieh; Nakhaei, Mohammadreza
2015-01-01
Background: The final position of the abutment changes with the amount of tightening torque. This could eventually lead to loss of passivity and marginal misfit of prostheses. The aim of this study was to evaluate the effect of three different tightening torques on the marginal adaptation of 3-unit cement-retained implant-supported fixed dental prostheses (FDPs). Materials and Methods: Two implants (Straumann) were inserted in an acrylic block so that one of the implants was placed vertically and the other at a 15° vertical angle. A straight abutment and a 15° angulated abutment were connected to the vertically and obliquely installed implants, respectively, so that the two abutments were parallel. Then, 10 cement-retained FDPs were waxed and cast. Abutments were tightened with 10, 20, and 35 Ncm torques, respectively. Following each tightening torque, FDPs were luted on respective abutments with temporary cement. The marginal adaptation of the retainers was evaluated using stereomicroscope. FDPs were then removed from the abutments and were sectioned at the connector sites. The retainers were luted again on their respective abutments. Luting procedures and marginal adaptation measurement were repeated. Data were analyzed by ANOVA and least significant difference tests (α = 0.05). After cutting the FDP connectors, the independent samples t-test was used to compare misfit values (α = 0.05). Results: Following 10, 20, and 35 Ncm tightening torques, the marginal discrepancy of the retainers of FDPs significantly increased (P < 0.05). There was no significant difference between the marginal discrepancies of these two retainers (P > 0.05). The marginal gap values of angulated abutment retainers (ANRs) were significantly higher than those of the straight abutment after cutting the connectors (P = 0.026). Conclusion: Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers. PMID:26288627
Ghanbarzadeh, Jalil; Dashti, Hossin; Karamad, Reza; Alikhasi, Marzieh; Nakhaei, Mohammadreza
2015-01-01
The final position of the abutment changes with the amount of tightening torque. This could eventually lead to loss of passivity and marginal misfit of prostheses. The aim of this study was to evaluate the effect of three different tightening torques on the marginal adaptation of 3-unit cement-retained implant-supported fixed dental prostheses (FDPs). Two implants (Straumann) were inserted in an acrylic block so that one of the implants was placed vertically and the other at a 15° vertical angle. A straight abutment and a 15° angulated abutment were connected to the vertically and obliquely installed implants, respectively, so that the two abutments were parallel. Then, 10 cement-retained FDPs were waxed and cast. Abutments were tightened with 10, 20, and 35 Ncm torques, respectively. Following each tightening torque, FDPs were luted on respective abutments with temporary cement. The marginal adaptation of the retainers was evaluated using stereomicroscope. FDPs were then removed from the abutments and were sectioned at the connector sites. The retainers were luted again on their respective abutments. Luting procedures and marginal adaptation measurement were repeated. Data were analyzed by ANOVA and least significant difference tests (α = 0.05). After cutting the FDP connectors, the independent samples t-test was used to compare misfit values (α = 0.05). Following 10, 20, and 35 Ncm tightening torques, the marginal discrepancy of the retainers of FDPs significantly increased (P < 0.05). There was no significant difference between the marginal discrepancies of these two retainers (P > 0.05). The marginal gap values of angulated abutment retainers (ANRs) were significantly higher than those of the straight abutment after cutting the connectors (P = 0.026). Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers.
Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques
Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent
2011-01-01
Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses. PMID:21912504
[Modern polyurethanes in cardiovascular surgery].
Gostev, A A; Laktionov, P P; Karpenko, A A
Currently, there is great clinical demand for synthetic tissue-engineered cardiovascular prostheses with good long-term patency. Polyurethanes belong to the class of polymers with excellent bio- and hemocompatibility. They are known to possess good mechanical properties, but are prone to processes of degradation in conditions of functioning in living organisms. Attempts at solving this problem have resulted in the development of various new subclasses of polyurethanes such as thermoplastic polyether polyurethanes, polyurethanes with a silicone segment, polycarbonate polyurethanes and nanocomposite polyurethanes. This was accompanied and followed by offering a series of new technologies of production of implantable medical devices such as vascular grafts, heart valves and others. In the presented review, we discuss biological and mechanical properties of modern subclasses of polyurethanes, as well as modern methods of manufacturing implantable medical devices made of polyurethanes, especially small-diameter vascular prostheses.
Twenty-first century challenges for biomaterials
Hench, Larry L.; Thompson, Ian
2010-01-01
During the 1960s and 1970s, a first generation of materials was specially developed for use inside the human body. These developments became the basis for the field of biomaterials. The devices made from biomaterials are called prostheses. Professor Bill Bonfield was one of the first to recognize the importance of understanding the mechanical properties of tissues, especially bone, in order to achieve reliable skeletal prostheses. His research was one of the pioneering efforts to understand the interaction of biomaterials with living tissues. The goal of all early biomaterials was to ‘achieve a suitable combination of physical properties to match those of the replaced tissue with a minimal toxic response in the host’. By 1980, there were more than 50 implanted prostheses in clinical use made from 40 different materials. At that time, more than three million prosthetic parts were being implanted in patients worldwide each year. A common feature of most of the 40 materials was biological ‘inertness’. Almost all materials used in the body were single-phase materials. Most implant materials were adaptations of already existing commercial materials with higher levels of purity to eliminate release of toxic by-products and minimize corrosion. This article is a tribute to Bill Bonfield's pioneering efforts in the field of bone biomechanics, biomaterials and interdisciplinary research. It is also a brief summary of the evolution of bioactive materials and the opportunities for tailoring the composition, texture and surface chemistry of them to meet five important challenges for the twenty-first century. PMID:20484227
[Preliminary evaluation of plastic crown restoration supported by osseointegrated implants].
Huang, J; Zhang, K
1997-08-01
This study was to evaluate the feasibility of plastic crown restoration supported by osseointegrated implants. The following conclusions were drawn from this study: plastic crown gave better biomechanical consideration than porcelain fused to metal (PFM) crown in osseointegrated prostheses, but plastic crown gave worse wearability, tensile strength, compression strength and flexuaral strength than PFM crown. After restoration the disadvantages of the plastic crown were beyond the clinical acceptable range. It showed plastic crown designed dental prothetic implantation was unfeasible.
Use of implantable prostheses for the treatment of urinary incontinence and impotence.
Kaufman, J J; Raz, S
1975-08-01
Silicone-Silastic implants to restore continence and potency have been used in one hundred twenty and twenty-five patients, respectively, and in eight patients a combined anti-impotence and anti-incontinence operation has been performed. The results have been gratifying, the complication rate has been minimal with fewer than five patients in our series having infection and a draining perineal sinus after the incontinence implant, and in no patient have delayed problems with the penile implants developed. Because of the design of the penile implants, fracture is extremely unlikely to occur, and the rods can be replaced if necessary because of inadequate length or asymmetry.
Oryan, Ahmad; Moshiri, Ali; Parizi, Abdolhamid Meimandi
2014-01-01
Surgical reconstruction of large Achilles tendon defects is technically demanding. There is no standard method, and tissue engineering may be a valuable option. We investigated the effects of 3D collagen and collagen-polydioxanone sheath (PDS) implants on a large tendon defect model in rabbits. Ninety rabbits were divided into three groups: control, collagen, and collagen-PDS. In all groups, 2 cm of the left Achilles tendon were excised and discarded. A modified Kessler suture was applied to all injured tendons to retain the gap length. The control group received no graft, the treated groups were repaired using the collagen only or the collagen-PDS prostheses. The bioelectrical characteristics of the injured areas were measured at weekly intervals. The animals were euthanized at 60 days after the procedure. Gross, histopathological and ultrastructural morphology and biophysical characteristics of the injured and intact tendons were investigated. Another 90 pilot animals were also used to investigate the inflammatory response and mechanism of graft incorporation during tendon healing. The control tendons showed severe hyperemia and peritendinous adhesion, and the gastrocnemius muscle of the control animals showed severe atrophy and fibrosis, with a loose areolar connective tissue filling the injured area. The tendons receiving either collagen or collagen-PDS implants showed lower amounts of peritendinous adhesion, hyperemia and muscle atrophy, and a dense tendon filled the defect area. Compared to the control tendons, application of collagen and collagen-PDS implants significantly improved water uptake, water delivery, direct transitional electrical current and tissue resistance to direct transitional electrical current. Compared to the control tendons, both prostheses showed significantly increased diameter, density and alignment of the collagen fibrils and maturity of the tenoblasts at ultrastructure level. Both prostheses influenced favorably tendon healing compared to the control tendons, with no significant differences between collagen and collagen-PDS groups. Implantation of the 3D collagen and collagen-PDS implants accelerated the production of a new tendon in the defect area, and may become a valuable option in clinical practice. PMID:24004331
Application of computer graphics in the design of custom orthopedic implants.
Bechtold, J E
1986-10-01
Implementation of newly developed computer modelling techniques and computer graphics displays and software have greatly aided the orthopedic design engineer and physician in creating a custom implant with good anatomic conformity in a short turnaround time. Further advances in computerized design and manufacturing will continue to simplify the development of custom prostheses and enlarge their niche in the joint replacement market.
Alikhasi, Marzieh; Kazemi, Mahmood; Nokar, Saeed; Khojasteh, Arash; Sheikhzadeh, Sedigheh
2011-01-01
This clinical report presents a 46-year-old man diagnosed with nasopharyngeal carcinoma with the chief complaint of masticatory and speech deficiency because of radiation therapy. After a period of controlling post radiation caries, the patient was rehabilitated with tooth and implant supported metal ceramic restorations following surgical and endodontic intervention. PMID:22090777
Tang, L; Lund, J P; Taché, R; Clokie, C M; Feine, J S
1999-09-01
Sixteen edentulous subjects participated in a within-subject crossover clinical trial to test the hypotheses that a long-bar overdenture attached to 4 implants gives greater patient satisfaction and masticatory efficiency than a two-implant hybrid overdenture. All subjects were given a new maxillary conventional denture. Ten received mandibular long-bar overdentures first and six the hybrid overdentures. Two months later, psychometric assessments and functional tests were repeated 3 times at one-week intervals. The mandibular prosthesis was then changed, and recordings were repeated after another 2 months. Mandibular movements and electromyographic activity of jaw muscles were recorded while subjects chewed standard-sized pieces of 5 foods: bread, cheese, apple, sausage, and carrot. Measurements included masticatory time, cleaning time (the time between the end of mastication and the last swallow), and duration and amplitude of masticatory cycles and phases. Multilevel analyses were performed. No significant differences in masticatory time were found between prostheses for any test food. However, cleaning time for carrot [estimated mean of difference (delta) +/- SE: 1.6 sec +/- 0.7] and bread (delta = 1.0 sec +/- 0.4) was slightly but significantly longer for subjects wearing long-bar overdentures. Cycle duration was longer with the long-bar overdenture only for subjects chewing carrot. The opening phase was shorter and the closing phase longer with the long-bar overdenture for almost all test foods. Vertical amplitude was significantly less with the long-bar overdenture for cheese (delta = -2.6 mm +/- 1.1), apple (delta = -2.6 mm +/- 1.0), and sausage (delta = -2.9 mm +/- 1.3). These results suggest that mastication with the 2 prostheses is equally efficient, although clearance of some foods from the mouth is longer with the long-bar overdentures. They also indicate that patients adapt their masticatory movements to the characteristics of different prostheses.
Bringing Hearing to the Deaf--Cochlear Implants: a Technical and Personal Account
NASA Astrophysics Data System (ADS)
Shipsey, Ian
2006-04-01
Cochlear implants are the first device to successfully restore neural function. They have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. In this talk the physiology of natural hearing will be reviewed from the perspective of a physicist, and the function of cochlear implants will be described in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. The social implications of cochlear implantation and the future outlook for auditory prostheses will also be discussed.
NASA Astrophysics Data System (ADS)
Oudadesse, H.; Irigaray, J. L.; Barbotteau, Y.; Brun, V.; Moretto, Ph.
2002-05-01
Bioactive glasses are used as coating biomaterials to facilitate anchorage of metallic prostheses implanted into the body. The aim of this work is to study the behavior of gel formed in contact with alloys and BVA and BVH bioactive glasses implanted. Cylinders of metallic implants composed by Ti, Al and V, are coated with bioactive glass. Three sheep were implanted for different time length: 3, 6 and 12 months in the femoral epiphysis. Results obtained with particle induced X-ray emission and scanning electron microscopy show that BVA coating induces a better contact between the metallic implant and bone. On the other hand, BVH coating prevents corrosion from the metallic implant.
Cement-retained versus screw-retained implant restorations: a critical review.
Michalakis, Konstantinos X; Hirayama, Hiroshi; Garefis, Pavlos D
2003-01-01
This article presents a comparison of screw-retained and cement-retained implant prostheses based on the literature. The advantages, disadvantages, and limitations of the 2 different types of restorations are discussed, because it is important to understand the influence of the attachment mechanism on many clinical aspects of implant dentistry. Several factors essential to the long-term success of any implant prosthesis were reviewed with regard to both methods of fixation. These factors include: (1) ease of fabrication and cost, (2) passivity of the framework, (3) retention, (4) occlusion, (5) esthetics, (6) delivery, and (7) retrievability. (More than 50 references).
Potential biomedical applications of ion beam technology
NASA Technical Reports Server (NTRS)
Banks, B. A.; Weigand, A. J.; Babbush, C. A.; Vankampen, C. L.
1976-01-01
Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.
Potential biomedical applications of ion beam technology
NASA Technical Reports Server (NTRS)
Banks, B. A.; Weigand, A. J.; Van Kampen, C. L.; Babbush, C. A.
1976-01-01
Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.
Stieglitz, T
2010-08-01
Stimulation of the nervous system with the aid of electrical active implants has changed the therapy of neurological diseases and rehabilitation of lost functions and has expanded clinical practice within the last few years. Alleviation of effects of neurodegenerative diseases, therapy of psychiatric diseases, the functional restoration of hearing as well as other applications have been transferred successfully into clinical practice. Other approaches are still under development in preclinical and clinical trials. The restoration of sight by implantable electronic systems that interface with the retina in the eye is an example how technological progress promotes novel medical devices. The idea of using the electrical signal of the brain to control technical devices and (neural) prostheses is driving current research in the field of brain-computer interfaces. The benefit for the patient always has to be balanced with the risks and side effects of those implants in comparison to medicinal and surgical treatments. How these and other developments become established in practice depends finally on their acceptance by the patients and the reimbursement of their costs.
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.
Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon; Lee, Keun-Woo
2016-12-01
The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 10 6 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups ( P >.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.
Microscopical analysis of synovial fluid wear debris from failing CoCr hip prostheses
NASA Astrophysics Data System (ADS)
Ward, M. B.; Brown, A. P.; Cox, A.; Curry, A.; Denton, J.
2010-07-01
Metal on metal hip joint prostheses are now commonly implanted in patients with hip problems. Although hip replacements largely go ahead problem free, some complications can arise such as infection immediately after surgery and aseptic necrosis caused by vascular complications due to surgery. A recent observation that has been made at Manchester is that some Cobalt Chromium (CoCr) implants are causing chronic pain, with the source being as yet unidentified. This form of replacement failure is independent of surgeon or hospital and so some underlying body/implant interface process is thought to be the problem. When the synovial fluid from a failed joint is examined particles of metal (wear debris) can be found. Transmission Electron Microscopy (TEM) has been used to look at fixed and sectioned samples of the synovial fluid and this has identified fine (< 100 nm) metal and metal oxide particles within the fluid. TEM EDX and Electron Energy Loss Spectroscopy (EELS) have been employed to examine the composition of the particles, showing them to be chromium rich. This gives rise to concern that the failure mechanism may be associated with the debris.
Mechanical compatibility of sol-gel annealing with titanium for orthopaedic prostheses.
Greer, Andrew I M; Lim, Teoh S; Brydone, Alistair S; Gadegaard, Nikolaj
2016-01-01
Sol-gel processing is an attractive method for large-scale surface coating due to its facile and inexpensive preparation, even with the inclusion of precision nanotopographies. These are desirable traits for metal orthopaedic prostheses where ceramic coatings are known to be osteoinductive and the effects may be amplified through nanotexturing. However there are a few concerns associated with the application of sol-gel technology to orthopaedics. Primarily, the annealing stage required to transform the sol-gel into a ceramic may compromise the physical integrity of the underlying metal. Secondly, loose particles on medical implants can be carcinogenic and cause inflammation so the coating needs to be strongly bonded to the implant. These concerns are addressed in this paper. Titanium, the dominant material for orthopaedics at present, is examined before and after sol-gel processing for changes in hardness and flexural modulus. Wear resistance, bending and pull tests are also performed to evaluate the ceramic coating. The findings suggest that sol-gel coatings will be compatible with titanium implants for an optimum temperature of 500 °C.
Prediction and control of neural responses to pulsatile electrical stimulation
NASA Astrophysics Data System (ADS)
Campbell, Luke J.; Sly, David James; O'Leary, Stephen John
2012-04-01
This paper aims to predict and control the probability of firing of a neuron in response to pulsatile electrical stimulation of the type delivered by neural prostheses such as the cochlear implant, bionic eye or in deep brain stimulation. Using the cochlear implant as a model, we developed an efficient computational model that predicts the responses of auditory nerve fibers to electrical stimulation and evaluated the model's accuracy by comparing the model output with pooled responses from a group of guinea pig auditory nerve fibers. It was found that the model accurately predicted the changes in neural firing probability over time to constant and variable amplitude electrical pulse trains, including speech-derived signals, delivered at rates up to 889 pulses s-1. A simplified version of the model that did not incorporate adaptation was used to adaptively predict, within its limitations, the pulsatile electrical stimulus required to cause a desired response from neurons up to 250 pulses s-1. Future stimulation strategies for cochlear implants and other neural prostheses may be enhanced using similar models that account for the way that neural responses are altered by previous stimulation.
Noguchi, Tadahide; Tsuchiya, Yoshiyuki; Sarukawa, Shunji; Yamazaki, Yuko; Hayasaka, Jun-Ichi; Sasaguri, Ken-Ichi; Jinbu, Yoshinori; Mori, Yoshiyuki
2016-07-01
The purpose of this study was to investigate the relationship between habitual chewing side and perception of the oral mucosa following reconstruction with dental implants. Five patients comprised 2 males and 3 females, with ameloblastoma in 2 patients, odontogenic myxoma in 2 patients, and oral squamous cell carcinoma in 1 patient. They were treated using mandibular reconstruction with bare bone graft after segmental resection of the mandible. Perception (tactile, warm, and cold) was measured at 8 points (chin, lower lip, gingiva, and lateral edge of the tongue, bilaterally). Habitual chewing side was evaluated using a computerized index, the first chewing cycle, and a question on chewing. Perception on resected sides was improved at all measurement points for tactile and cold sensitive evaluation, although sensitivities on the resected side remained below the normal range. In the relationship between habitual chewing side and implanted prostheses in reconstructed bone, the chewing side was the resected side in 2 of the 5 patients. When those 2 patients underwent prosthesis implantation after removal of denture, the chewing side changed from the nonresected side to the resected side. Implant prostheses on resected side were suggested to contribute to masticatory function. Perception in those patients was incomplete but was improved compared with other patients. When prosthesis implantation is performed on the reconstructed side, the resected side may become the habitual chewing side. Recovery of perception can influence acquisition of the habitual chewing side.
[How do metallic middle ear implants behave in the MRI?].
Kwok, P; Waldeck, A; Strutz, J
2003-01-01
Magnetic resonance imaging (MRI) has gained in frequency and importance as a diagnostic procedure. In respect to the close anatomical relationship in the temporal bone it is necessary to know whether it is hazardous to patients with metallic middle ear implants regarding displacement and rise in temperature. For the MR image quality artefacts caused by metallic prostheses should be low. Four different stapes prostheses made from titanium, gold, teflon/platinum and teflon/steel, a titanium total ossicular reconstruction prosthesis (TORP) and two ventilation tubes (made from titanium and gold) were tested in a 1.5 Tesla MRI machine regarding their displacement. All objects were first placed in a petri dish, then suspended from a thread and finally immersed in a dish filled with Gadolinium. Temperature changes of the implants were recorded by a pyrometer. None of the implants moved when they were placed in the petri dish or suspended from the thread. On the water surface the teflon/platinum and the teflon/steel pistons adjusted their direction with their axis longitudinally to the MRI scanner opening and the teflon/steel piston floated towards the MRI-machine when put close enough to the scanner opening. No rise in temperature was recorded. All implants showed as little artefacts that would still make an evaluation of the surrounding tissue possible. Patients with any of the metallic middle ear implants that were examined in this study may undergo MRI-investigations without significant adverse effects.
Mendes, Stella de N C; Edwards Rezende, Carlos E; Moretti Neto, Rafael T; Capello Sousa, Edson A; Henrique Rubo, José
2013-04-01
Passive fit has been considered an important requirement for the longevity of implant-supported prostheses. Among the different steps of prostheses construction, casting is a feature that can influence the precision of fit and consequently the uniformity of possible deformation among abutments upon the framework connection. This study aimed at evaluating the deformation of abutments after the connection of frameworks either cast in one piece or after soldering. A master model was used to simulate a human mandible with 5 implants. Ten frameworks were fabricated on cast models and divided into 2 groups. Strain gauges were attached to the mesial and distal sides of the abutments to capture their deformation after the framework's screw retentions were tightened to the abutments. The mean values of deformation were submitted to a 3-way analysis of variance that revealed significant differences between procedures and the abutment side. The results showed that none of the frameworks presented a complete passive fit. The soldering procedure led to a better although uneven distribution of compression strains on the abutments.
Kim, Seok-Gyu; Son, Mee-Kyoung
2015-01-01
PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening. PMID:26140172
Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants.
Ferreira, Mayara Barbosa; Delben, Juliana Aparecida; Barão, Valentim Adelino Ricardo; Faverani, Leonardo Perez; Dos Santos, Paulo Henrique; Assunção, Wirley Gonçalves
2012-11-01
The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention screws of tapered abutments and cylinders of Morse taper implants submitted to retightening and detorque measurements. Two groups were obtained (n = 12): group I-tapered abutment connected to the implant with titanium retention screw and group II-cylinder with metallic base connected to tapered abutment with titanium retention screw. The detorque values were measured by an analogic torque gauge after 3 minutes of torque insertion. The detorque was measured 10 times for each retention screw of groups I and II, totalizing 120 detorque measurements in each group. Data were submitted to ANOVA and Fisher exact test (P < 0.05). Both groups presented reduced detorque value (P < 0.05) in comparison to the insertion torque in all measurement periods. There was a statistically significant difference (P < 0.05) between the detorque values of the first measurement and the other measurement periods for the abutment screw. However, there was no statistically significant difference (P > 0.05) for the detorque values of all measurement periods for the cylinder screw. In conclusion, the abutment and cylinder screws exhibited torque loss after insertion, which indicates the need for retightening during function of the implant-supported prostheses.
Kharade, Pankaj; Banerjee, Ardhendu; Gupta, Tapas
2012-01-01
A diagnostic radiograph of the posterior regions of the jaws is mandatory if implant placement is considered at these sites. The goal is to avoid damage to important anatomical structures such as the inferior alveolar canal and maxillary sinus. Using radiographs to evaluate the remaining bone height available for implant insertion is a common procedure. Many articles have evaluated the success rates of fixed prostheses supported by osseointegrated implants, indicating high rates of success for prostheses 5-10 years in function. However, if an orthopantomogram machine is not readily available, periapical radiographs can be used for vertical bone height assessment. The familiar procedure of incorporating a metal ball of known diameter into an acrylic template is the method of choice. This is a relatively tedious and expensive procedure involving multiple steps, including impression taking, creation of a study model, and manufacture of a metal ball-bearing acrylic template. A further disadvantage for the patient is that a diagnostic radiograph can be taken only at the next appointment. This paper describes a quick and simple method to obtain a radiographic evaluation of remaining alveolar bone height and soft tissue thickness prior to implant placement with help of a metal ball device to avoid template fabrication and time consumption. Soft tissue thickness is measured nonsurgically.
Assunção, Wirley Gonçalves; Gomes, Erica Alves; Rocha, Eduardo Passos; Delben, Juliana Aparecida
2011-01-01
Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 μm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 μm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 μm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system.
Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Araujo Lemos, Cleidiel Aparecido; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza
The aim of this study was to use three-dimensional finite element analysis to analyze the stress distribution transferred by single implant-supported prostheses placed in the anterior maxilla using different connections (external hexagon, internal hexagon, or Morse taper), inclinations of the load (0, 30, or 60 degrees), and surgical techniques for placement (monocortical/conventional, bicortical, or bicortical with nasal floor elevation). Nine models representing a bone block of this region were simulated by computer-aided design software (InVesalius, Rhinoceros, SolidWorks). Each model received one implant, which supported a cemented metalloceramic crown. Using FEMAP software, finite elements were discretized while simulating a 178-N load at 0, 30, and 60 degrees relative to the long axis of the implant. The problem was solved in NEi Nastran software, and postprocessing was performed in FEMAP. Von Mises stress and maximum principal stress maps were made. The von Mises stress analysis revealed that stress increased with increasing inclination of the load, from 0 to 30 to 60 degrees. Morse taper implants showed less stress concentration around the cervical and apical areas of the implant. The bicortical technique, associated or not with nasal floor elevation, contributed to decreasing the stress concentration in the apical area of the implant. Maximum principal stress analysis showed that the increase in inclination was proportional to the increase in stress on the bone tissue in the cervical area. Lower stress concentrations in the cortical bone were obtained with Morse taper implants and the bicortical technique compared with other connections and surgical techniques, respectively. Increasing the inclination of the applied force relative to the long axis of the implant tended to overload the peri-implant bone tissue and the internal structure of the implants. The Morse taper connection and bicortical techniques seemed to be more favorable than other connections or techniques, respectively, for restoring the anterior maxilla.
Lee, Mi-Young; Heo, Seong-Joo; Park, Eun-Jin; Park, Ji-Man
2013-08-01
The aim of this study was to compare the passivity of implant superstructures by assessing the strain development around the internal tapered connection implants with strain gauges. A polyurethane resin block in which two implants were embedded served as a measurement model. Two groups of implant restorations utilized cement-retained design and internal surface of the first group was adjusted until premature contact between the restoration and the abutment completely disappeared. In the second group, only nodules detectable to the naked eye were removed. The third group employed screw-retained design and specimens were generated by computer-aided design/computer-aided manufacturing system (n=10). Four strain gauges were fixed on the measurement model mesially and distally to the implants. The strains developed in each strain gauge were recorded during fixation of specimens. To compare the difference among groups, repeated measures 2-factor analysis was performed at a level of significance of α=.05. The absolute strain values were measured to analyze the magnitude of strain. The mean absolute strain value ranged from 29.53 to 412.94 µm/m at the different strain gauge locations. According to the result of overall comparison, the cement-retained prosthesis groups exhibited significant difference. No significant difference was detected between milled screw-retained prostheses group and cement-retained prosthesis groups. Within the limitations of the study, it was concluded that the cement-retained designs do not always exhibit lower levels of stress than screw-retained designs. The internal adjustment of a cement-retained implant restoration is essential to achieve passive fit.
NASA Astrophysics Data System (ADS)
Wang, Chun; Brunton, Emma; Haghgooie, Saman; Cassells, Kahli; Lowery, Arthur; Rajan, Ramesh
2013-08-01
Objective. Cortical neural prostheses with implanted electrode arrays have been used to restore compromised brain functions but concerns remain regarding their long-term stability and functional performance. Approach. Here we report changes in electrode impedance and stimulation thresholds for a custom-designed electrode array implanted in rat motor cortex for up to three months. Main Results. The array comprises four 2000 µm long electrodes with a large annular stimulating surface (7860-15700 µm2) displaced from the penetrating insulated tip. Compared to pre-implantation in vitro values there were three phases of impedance change: (1) an immediate large increase of impedance by an average of two-fold on implantation; (2) a period of continued impedance increase, albeit with considerable variability, which reached a peak at approximately four weeks post-implantation and remained high over the next two weeks; (3) finally, a period of 5-6 weeks when impedance stabilized at levels close to those seen immediately post-implantation. Impedance could often be temporarily decreased by applying brief trains of current stimulation, used to evoke motor output. The stimulation threshold to induce observable motor behaviour was generally between 75-100 µA, with charge density varying from 48-128 µC cm-2, consistent with the lower current density generated by electrodes with larger stimulating surface area. No systematic change in thresholds occurred over time, suggesting that device functionality was not compromised by the factors that caused changes in electrode impedance. Significance. The present results provide support for the use of annulus electrodes in future applications in cortical neural prostheses.
An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.
Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza
2014-07-01
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
Esquivel-Upshaw, Josephine F.; Clark, Arthur E.; Shuster, Jonathan J.; Anusavice, Kenneth J.
2013-01-01
Purpose The aim of this study was to determine the survival rates over time of implant-supported ceramic-ceramic and metal-ceramic prostheses as a function of core-veneer thickness ratio, gingival connector embrasure design, and connector height. Materials and Methods An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study involving 55 patients missing three teeth in either one or two posterior areas. These patients (34 women; 21 men; age range 52–75 years) were recruited for the study to receive a 3-unit implant-supported fixed dental prosthesis (FDP). Two implants were placed for each of the 72 FDPs in the study. The implants (Osseospeed, Astra Tech), which were made of titanium, were grit blasted. A gold-shaded, custom-milled titanium abutment (Atlantis, Astra Tech), was secured to each implant body. Each of the 72 FDPs in 55 patients were randomly assigned based on one of the following options: (1) A. Material: ceramic-ceramic (Yttria-stabilized zirconia core, pressable fluorapatite glass-ceramic, IPS e.max ZirCAD and ZirPress, Ivoclar Vivadent) B. metal-ceramic (palladium-based noble alloy, Capricorn, Ivoclar Vivadent, with press-on leucite-reinforced glass-ceramic veneer, IPS InLine POM, Ivoclar Vivadent); (2) occlusal veneer thickness (0.5, 1.0, and 1.5 mm); (3) curvature of gingival embrasure (0.25, 0.5, and 0.75 mm diameter); and (4) connector height (3, 4, and 5 mm). FDPs were fabricated and cemented with dual-cure resin cement (RelyX, Universal Cement, 3M ESPE). Patients were recalled at 6 months, 1 year, and 2 years. FDPs were examined for cracks, fracture, and general surface quality. Results Recall exams of 72 prostheses revealed 10 chipping fractures. No fractures occurred within the connector or embrasure areas. Two-sided Fisher’s exact tests showed no significant correlation between fractures and type of material system (p = 0.51), veneer thickness (p = 0.75), radius of curvature of gingival embrasure (p = 0.68), and connector height (p = 0.91). Conclusions Although there were no significant associations between connector height, curvature of gingival embrasure, core/veneer thickness ratio, and material system and the survival probability of implant-supported FDPs with zirconia as a core material, the small number of fractures precludes a definitive conclusion on the dominant controlling factor. PMID:23758092
Esquivel-Upshaw, Josephine F; Clark, Arthur E; Shuster, Jonathan J; Anusavice, Kenneth J
2014-02-01
The aim of this study was to determine the survival rates over time of implant-supported ceramic-ceramic and metal-ceramic prostheses as a function of core-veneer thickness ratio, gingival connector embrasure design, and connector height. An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study involving 55 patients missing three teeth in either one or two posterior areas. These patients (34 women; 21 men; age range 52-75 years) were recruited for the study to receive a three-unit implant-supported fixed dental prosthesis (FDP). Two implants were placed for each of the 72 FDPs in the study. The implants (Osseospeed, Astra Tech), which were made of titanium, were grit blasted. A gold-shaded, custom-milled titanium abutment (Atlantis, Astra Tech), was secured to each implant body. Each of the 72 FDPs in 55 patients were randomly assigned based on one of the following options: (1) A. ceramic-ceramic (Yttria-stabilized zirconia core, pressable fluorapatite glass-ceramic, IPS e.max ZirCAD, and ZirPress, Ivoclar Vivadent) B. metal-ceramic (palladium-based noble alloy, Capricorn, Ivoclar Vivadent, with press-on leucite-reinforced glass-ceramic veneer, IPS InLine POM, Ivoclar Vivadent); (2) occlusal veneer thickness (0.5, 1.0, and 1.5 mm); (3) curvature of gingival embrasure (0.25, 0.5, and 0.75 mm diameter); and (4) connector height (3, 4, and 5 mm). FDPs were fabricated and cemented with dual-cure resin cement (RelyX, Universal Cement, 3M ESPE). Patients were recalled at 6 months, 1 year, and 2 years. FDPs were examined for cracks, fracture, and general surface quality. Recall exams of 72 prostheses revealed 10 chipping fractures. No fractures occurred within the connector or embrasure areas. Two-sided Fisher's exact tests showed no significant correlation between fractures and type of material system (p = 0.51), veneer thickness (p = 0.75), radius of curvature of gingival embrasure (p = 0.68), and connector height (p = 0.91). Although there were no significant associations between connector height, curvature of gingival embrasure, core/veneer thickness ratio, and material system and the survival probability of implant-supported FDPs with zirconia as a core material, the small number of fractures precludes a definitive conclusion on the dominant controlling factor. © 2013 by the American College of Prosthodontists.
Setia, Gaurav; Yousef, Hoda; Ehrenberg, David; Luke, Allyn; Weiner, Saul
2013-08-01
The purpose of this study was to use an in vitro model system to compare the effects on the screw torque and screw dimensions within 2 commercially available implant systems from occlusal loading on a cantilevered-fixed partial denture. Cantilevered implant-supported 3-unit prostheses with 2 premolar abutments and 1 premolar pontic (7.3 mm in length) were made on resin casts containing 2 implant analogs for 2 implant systems: BioLok Silhouette Tapered Implant System (Birmingham, AL) and Zimmer Tapered Screw-Vent Implant System (Carlsbad, CA) with 10 samples in each group. Each sample was loaded with either of 2 protocols: (1) a load of 50 N on the cantilevered pontic unit and (2) a loading of 150 N on all 3 units. The outcome measures were (1) changes in residual torque of the abutment screws and (2) changes in screw dimension. The BioLok Silhouette Tapered Implant group demonstrated slight but statistically significant torque loss 18.8% to 28.5% in both abutment screws for both protocols, P ≤ 0.05, without any changes in screw dimension. In the Zimmer Tapered Screw-Vent Implant group, there was a significant elongation of the abutment screws and a markedly significant 44.4%, (P ≤ 0.01) loss in torque in the mesial screw and a 28.5%, (P ≤ 0.05) loss in torque in the distal screw when the cantilever alone was loaded. Differences in screw design influence the maintenance of preload and distortion of the shank. The influence of the interface design, namely an internal hex of 1 mm versus an external hex did not influence the preload. Cantilevered prostheses can cause loss of torque and dimensional changes in abutment screws.
Teigen, Kyrre; Jokstad, Asbjørn
2012-07-01
An association between the long-term success and survival of implant-supported prostheses as a function of biomaterial combinations has not been established. The use of cast cobalt-chromium for the suprastructure framework may be an alternative to the conventional approach of using type 3 gold alloys. A retrospective chart audit of all patients who had received implant-supported fixed dental prostheses (FDP) before 1996 was identified in a private practice clinic. Data were recorded for FDPs made from four combinations of alloy frameworks and veneering material, i.e. type 3 gold and cobalt-chromium with ceramic or prefabricated acrylic teeth. The extracted data from the charts were subjected to explorative statistical tests including Kaplan-Meier survival analyses. Patients (n=198) with 270 short and extensive FDPs supported entirely by 1117 implants were identified. The average follow-up observation periods varied between 4 and 220 months, with an average of 120 months. The success and survival, as well as event rates and types of biological and technical complications, were similar for implant-supported FDPs using cobalt-chromium and type 3 gold alloy frameworks veneered with ceramics or prefabricated acrylic teeth. An influence of the suprastructure biomaterial combination on the clinical performance of the individual supporting implants could not be established. Implant-supported FDPs made from type 3 gold or cobalt-chromium frameworks and veneered with ceramic or prefabricated acrylic teeth demonstrate comparable clinical performance. The biomaterial combinations do not appear to influence the success or survival of the individual implants. © 2011 John Wiley & Sons A/S.
Fugazzotto, P A; Kirsch, A; Ackermann, K L; Neuendorff, G
1999-01-01
Numerous problems have been reported following various therapies used to attach natural teeth to implants beneath a fixed prosthesis. This study documents the results of 843 consecutive patients treated with 1,206 natural tooth/implant-supported prostheses utilizing 3,096 screw-fixed attachments. After 3 to 14 years in function, only 9 intrusion problems were noted. All problems were associated with fractured or lost screws. This report demonstrates the efficacy of such a treatment approach when a natural tooth/implant-supported fixed prosthesis is contemplated.
NASA Astrophysics Data System (ADS)
Auciello, Orlando; Shi, Bing
Extensive research has been devoted to the development of neuron prostheses and hybrid bionic systems to establish links between the nervous system and electronic or robotic prostheses with the main focus of restoring motor and sensory functions in blind patients. Artificial retinas, one type of neural prostheses we are currently working on, aim to restore some vision in blind patients caused by retinitis picmentosa or macular degeneration, and in the future to restore vision at the level of face recognition, if not more. Currently there is no hermetic microchip-size coating that provides a reliable, long-term (years) performance as encapsulating coating for the artificial retina Si microchip to be implanted inside the eye. This chapter focuses on the critical topics relevant to the development of a robust, long-term artificial retina device, namely the science and technology of hermetic bio-inert encapsulating coatings to protect a Si microchip implanted in the human eye from being attacked by chemicals existing in the eye's saline environment. The work discussed in this chapter is related to the development of a novel ultrananocrystalline diamond (UNCD) hermetic coating, which exhibited no degradation in rabbit eyes. The material synthesis, characterization, and electrochemical properties of these hermetic coatings are reviewed for application as encapsulating coating for the artificial retinal microchips implantable inside the human eye. Our work has shown that UNCD coatings may provide a reliable hermetic bio-inert coating technology for encapsulation of Si microchips implantable in the eye specifically and in the human body in general. Electrochemical tests of the UNCD films grown under CH4/Ar/H2 (1%) plasma exhibit the lowest leakage currents (˜7 × 10-7 A/cm2) in a saline solution simulating the eye environment. This leakage is incompatible with the functionality of the first-generation artificial retinal microchip. However, the growth of UNCD on top of the Si microchip passivated by a silicon nitride layer or the oxide layers is also under investigation in our group as introduced in this chapter. The electrochemically induced leakage will be reduced by at least one to three orders of magnitude to the range of 10-10 A/cm2, which is compatible with reliable, long-term implants.
Development of a micromachined epiretinal vision prosthesis
NASA Astrophysics Data System (ADS)
Stieglitz, Thomas
2009-12-01
Microsystems engineering offers the tools to develop highly sophisticated miniaturized implants to interface with the nervous system. One challenging application field is the development of neural prostheses to restore vision in persons that have become blind by photoreceptor degeneration due to retinitis pigmentosa. The fundamental work that has been done in one approach is presented here. An epiretinal vision prosthesis has been developed that allows hybrid integration of electronics on one part of a thin and flexible substrate. Polyimide as a substrate material is proven to be non-cytotoxic. Non-hermetic encapsulation with parylene C was stable for at least 3 months in vivo. Chronic animal experiments proved spatially selective cortical activation after epiretinal stimulation with a 25-channel implant. Research results have been transferred successfully to companies that currently work on the medical device approval of these retinal vision prostheses in Europe and in the USA.
Prototyping for surgical and prosthetic treatment.
Goiato, Marcelo Coelho; Santos, Murillo Rezende; Pesqueira, Aldiéris Alves; Moreno, Amália; dos Santos, Daniela Micheline; Haddad, Marcela Filié
2011-05-01
Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE (PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.
Rinke, Sven; Ziebolz, Dirk; Ratka-Krüger, Petra; Frisch, Eberhard
2015-07-01
There is a lack of data regarding the clinical outcome of removable partial dentures (RPDs) supported by a combination of residual natural teeth and implants placed in strategic positions. The aim of the present case series was to conduct a retrospective investigation of the clinical outcome of mandibular tooth-implant-retained partial dentures (TIRPD) rigidly retained via telescopic double crowns. Between 1999 and 2010, 18 patients with reduced residual dentition (1 to 3 natural abutment teeth) and in need of an RPD received 1 to 3 implants in strategic positions for support of the removable prostheses. All TIRPDs were rigidly retained by telescopic crowns according to the Marburg Double Crown (MDC) technique; all prostheses were placed in a private practice. Tooth/implant survival and success rates, prosthetic maintenance requirements, and peri-implant parameters were analyzed retrospectively using patient records and clinical examinations during the final recall appointments. Only patients attending at least annual supportive post-implant hygiene therapy visits (SIT) were included. After a mean functional period of 5.84 ± 3 years (range: 3.01-12.21), 14 patients with 14 dentures supported by 24 implants and 27 teeth (mean number of abutments: 3.6) were available for assessment. Four teeth (survival rate: 85.19%) and no implants (survival rate: 100%) were lost. Peri-implantitis was observed around one implant (4.17%). All 14 dentures were functional (survival rate: 100%) and required only limited maintenance (i.e., screw loosening, acrylic resin fracture repairs, relining) amounting to 0.086 treatments per patient per year (T/P/Y). Within the limitations of this case series, it can be concluded that TIRPDs retained via MDCs might represent a viable treatment option in mandibles with few remaining abutment teeth. Further long-term clinical evaluations with a greater sample size are needed for a more detailed evaluation of this treatment concept. © 2014 by the American College of Prosthodontists.
2011-01-01
Background Testicular prosthesis has been applied clinically for decades, and implantation of testis prosthesis under the tunica albuginea has been considered to be the standard method in the most of the reports. However, postoperative scrotal appearance, the mobilization and the palpitation of the prosthesis are not always satisfactory to all the patients. Modifications in surgical techniques might be necessary to bring improvements to the clinical outcomes in testicular prosthesis implantation. Findings In a group of 9 beagle dogs in this study, an orchiectomy succeeded with a testicular prosthesis implantation under the tunica vaginalis, and a complete mechanical denudation of the testicular parenchyma succeeded with an implantation under the tunica albuginea were performed, respectively. Histopathological evaluations of the scrotal tissues and the implants, which were made at the end of the follow-up, showed that all the tested animals lived uneventful lives during the follow-up period, and no rejections or infections were found. Prostheses implanted under the tunica vaginalis showed a more satisfying mobilization and palpation than those implanted under the tunica albuginea. Chronic inflammation in the para-prosthesis tissues with vascular proliferation and fibrinogenesis were more common in the "under tunica albuginea" group than that in the "under tunica vaginalis" group, although differences in fibrinogenesis between the two groups were found to be statistically insignificant. Conclusions In this comparative study, we have re-evaluated the two most popular implantation methods of testicular prosthesis, the "under the tunica albuginea" and the "under the tunica vaginalis" pathways, in animal models. We found that the testicular prosthesis were all well tolerated, but the prosthesis implanted under the tunica vaginalis showed a more satisfying result concerning appearance, palpability, and histopathological findings than that of the "under the tunica albuginea" group. The "under the tunica vaginalis" method might become a more practical method for future testicular prosthesis implantation. PMID:21457571
Retinal Implants for Blind Patients
NASA Astrophysics Data System (ADS)
Rothermel, Albrecht
Recently, very promising results have been obtained in clinical trials with eye-prostheses for the blind. There is a chance that advances in surgical techniques, microelectronics design, and material science may lead to the first really useful applications of retinal implants in the near future. This chapter will focus on the actual status of subretinal surgery and implant technologies. Opportunities and limitations of the different technologies will be discussed in terms of patients benefit and technological challenges. Finally, a vision on how the devices may work and look like in the future will be given.
Sethi, Karishma; Buckley, Jim; de Wolff, Jacob
2013-09-01
Infective endocarditis is a serious endo-vascular infection, potentially affecting not only native heart valves, but also intra-vascularly implanted foreign materials such as valvular prostheses and pacemaker electrodes (Westphal et al, 2009).
Influence of occlusal loading on peri-implant clinical parameters. A pilot study
Pellicer-Chover, Hilario; Viña-Almunia, José; Romero-Millán, Javier; Peñarrocha-Oltra, David; Peñarrocha-Diago, María
2014-01-01
Objectives: To investigate the relation between occlusal loading and peri-implant clinical parameters (probing depth, bleeding on probing, gingival retraction, width of keratinized mucosa, and crevicular fluid volume) in patients with implant-supported complete fixed prostheses in both arches. Material and Methods: This clinical study took place at the University of Valencia (Spain) dental clinic. It included patients attending the clinic for regular check-ups during at least 12 months after rehabilitation of both arches with implant-supported complete fixed ceramo-metallic prostheses. One study implant and one control implant were established for each patient using the T-Scan®III computerized system (Tesco, South Boston, USA). The maxillary implant closest to the point of maximum occlusal loading was taken as the study implant and the farthest (with least loading) as the control. Occlusal forces were registered with the T-Scan® III and then occlusal adjustment was performed to distribute occlusal forces correctly. Peri-implant clinical parameters were analyzed in both implants before and two and twelve months after occlusal adjustment. Results: Before occlusal adjustment, study group implants presented a higher mean volume of crevicular fluid (51.3±7.4 UP) than the control group (25.8±5.5 UP), with statistically significant difference. Two months after occlusal adjustment, there were no significant differences between groups (24.6±3.8 UP and 26±4.5 UP respectively) (p=0.977). After twelve months, no significant differences were found between groups (24.4±11.1 UP and 22.5±8.9 UP respectively) (p=0.323). For the other clinical parameters, no significant differences were identified between study and control implants at any of the study times (p>0.05). Conclusions: Study group implants receiving higher occlusal loading presented significantly higher volumes of crevicular fluid than control implants. Crevicular fluid volumes were similar in both groups two and twelve months after occlusal adjustment. Key words:Occlusal loading, crevicular fluid, peri-implant clinical parameters, T-Scan®. PMID:24316708
Creating natural-looking removable prostheses: combining art and science to imitate nature.
Patras, Michael; Kourtis, Stefanos; Sykaras, Nikitas
2012-06-01
Patient awareness of dental appearance has increased, resulting in more demanding esthetic requests. There is also strong evidence that increased esthetics is highly significant for complete denture acceptance and success. Taking notice of patients' perceptions of natural appearance and esthetics, the clinician can incorporate their preferences in the construction of individualized dentures that will be harmonized with their facial characteristics. Despite the evolution of materials and techniques, the vast majority of dentures still fail to look natural. Thus, producing prostheses that defy detection and successfully restore the appearance of edentulous patients remains a challenge for the clinician. This paper presents a clinical case where immediate loading of implants supporting a mandibular overdenture was combined with an opposing conventional maxillary denture to satisfy the high functional and esthetic demands of the patient. It also emphasizes the individualized esthetic performance through customization during their fabrication while taking into consideration the various clinical parameters affecting rehabilitation of the edentulous jaw. Implant-retained overdentures can significantly improve the patients' function. The esthetic performance of these restorations however, may not be satisfying the patients' expectations and demands. Customizing the artificial gingival areas and individual staining of the prefabricated acrylic teeth may improve the esthetic performance creating natural-looking removable prostheses. © 2011 Wiley Periodicals, Inc.
Guo, Bing-bing; Zheng, Xiao-lin; Lu, Zhen-gang; Wang, Xing; Yin, Zheng-qin; Hou, Wen-sheng; Meng, Ming
2015-01-01
Visual cortical prostheses have the potential to restore partial vision. Still limited by the low-resolution visual percepts provided by visual cortical prostheses, implant wearers can currently only “see” pixelized images, and how to obtain the specific brain responses to different pixelized images in the primary visual cortex (the implant area) is still unknown. We conducted a functional magnetic resonance imaging experiment on normal human participants to investigate the brain activation patterns in response to 18 different pixelized images. There were 100 voxels in the brain activation pattern that were selected from the primary visual cortex, and voxel size was 4 mm × 4 mm × 4 mm. Multi-voxel pattern analysis was used to test if these 18 different brain activation patterns were specific. We chose a Linear Support Vector Machine (LSVM) as the classifier in this study. The results showed that the classification accuracies of different brain activation patterns were significantly above chance level, which suggests that the classifier can successfully distinguish the brain activation patterns. Our results suggest that the specific brain activation patterns to different pixelized images can be obtained in the primary visual cortex using a 4 mm × 4 mm × 4 mm voxel size and a 100-voxel pattern. PMID:26692860
King, Elizabeth; Abbott, Carl; Dovgalski, Lawrence; Owens, James
2017-06-01
Nasal carcinoma extending into the premaxilla requires radical surgical excision including rhinectomy and partial maxillectomy. Rehabilitation is complex and involves the use of removable prostheses. Three patients treated with zygomatic implants and custom-milled bars to retain an obturator and nasal prosthesis are presented. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Patients' experiences of dental implant treatment: A literature review of key qualitative studies.
Kashbour, W A; Rousseau, N S; Ellis, J S; Thomason, J M
2015-07-01
To identify and summarise the findings of previous qualitative studies relating to patients' experience of dental implant treatment (DIT) at various stages of their implant treatment, by means of textual narrative synthesis. Original articles reporting patients' experience with dental implant were included. A two-stage search of the literature, electronic and hand search identified relevant qualitative studies up to July 2014. An extensive electronic search was conducted of databases including PubMed, Embase, Scopus, Web of Knowledge, Cochrane Database and Google Scholar. Included primary studies (n=10) used qualitative research methods and qualitative analysis to investigate patients' experiences with dental implants treatment. While the growing interest in implant treatment for the replacement of missing dentition is evident, it is essential to investigate patients' perceptions of different aspects of implant treatment. This textual narrative synthesis conducted to review qualitative studies which provided insight into patients' experience of two types of implant prostheses namely ISOD (implant-supported overdenture) and FISP (fixed implant supported prostheses). Primary reviewed studies tended to include samples of older patients with more extensive tooth loss, and to focus on experiences prior to and post-treatment rather than on the treatment period itself. Findings across reviewed studies (n=10) suggested that patients with FISP thought of implant treatment as a process of 'normalisation'(1) and believed that such implant restorations could be similar to natural teeth, whereas patients with ISOD focused more on the functional and social advantages of their implant treatment. The growing interest in qualitative research is evident in several branches of clinical dentistry and dental implantology is not an exception. Qualitative studies concerning the patients account of their experience of dental implants is however limited. The aim of this review is to firstly identify recent work within this field and to subsequently categorise it more consistently by means of textural narrative synthesis, thus highlighting similarities and differences and enabling identification of gaps in research knowledge thereby setting the direction of further research. Copyright © 2015 Elsevier Ltd. All rights reserved.
Intramuscular Contact Lead Filled With Conductive Solution
NASA Technical Reports Server (NTRS)
Bamford, Robert M.; Hendrickson, James A.
1991-01-01
Proposed sheath for braided-wire intramuscular conductor preserves electrical continuity even if wire breaks. Plastic sheath surrounds conductive solution in which braided wire immersed. At end of cable, wire and sheath crimped together and press-fit in porous titanium electrode. Implanted surgically with aid of device resembling catheter. Used to deliver electrical stimuli to muscles in biomedical research on human and animal physiology, development of prostheses, regeneration of nerves and muscles, and artificial implants.
Testicular Prostheses: Development and Modern Usage
Bodiwala, D; Summerton, DJ; Terry, TR
2007-01-01
INTRODUCTION Testicular prostheses produced from various materials have been in use since 1941. The absence of a testicle has been shown to be a psychologically traumatic experience for males of all ages. The indications for insertion of a prosthesis include absence or following orchidectomy from a number of causes such as malignancy, torsion and orchitis. The most common substance used around the world in the manufacture of these implants is silicone; however, in the US, this material is currently banned because of theoretical health risks. This has led to the development of saline-filled prostheses as an alternative. PATIENTS AND METHODS A Medline search was carried out on all articles on testicular prosthesis between 1966 and 2006. CONCLUSIONS This review highlights the controversies regarding prosthetic materials, the complications of insertion and the potential benefits of this commonly performed procedure. PMID:17535609
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant
Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon
2016-01-01
PURPOSE The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 106 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment. PMID:28018564
Battlefield-Acquired Immunogenicity to Metals Affects Orthopaedic Implant Outcome
2016-12-01
Briatico-Vangosa G, Kaestner W, Lally C, Bontinck WJ. Nickel, cobalt and chromium in consumer products: a role in allerg ic contact dermat itis? Contact ...T, Zitting A, Jolanki R, Tarvainen K. Nickel release from metals, and a case of allergic contact dermatitis from stainless steel. Contact Dermatit is... Dermat itis 1994;31:249-55. (30) Gawkrodger DJ. Nickel sensitivity and the implantation of orthopaedic prostheses. Contact Dermatit is 1993;28:257 -9
Pitkin, M.; Cassidy, C.; Muppavarapu, R.; Edell, David
2012-01-01
Direct recordings were made of electrical signals emanating from the muscles in a rabbit’s residuum. The signals were transmitted via wires attached on one end to the muscles, and on the other to an external recording system. The cable was held in a titanium tube inside a pylon that had been transcutaneously implanted into the residuum’s bone. The tube was surrounded by porous titanium cladding to enhance its bond with the bone and with the skin of the residuum. This study was the first known attempt to merge the technology of direct skeletal attachment of limb prostheses with the technology of neuromuscular control of prostheses, providing a safe and reliable passage of the electrical signal from the muscles inside the residuum to the outside recording system. PMID:22345523
Anchieta, Rodolfo Brunieira; Machado, Lucas Silveira; Hirata, Ronaldo; Bonfante, Estevam Augusto; Coelho, Paulo G
2016-08-01
The aim of this study was to evaluate the probability of survival of cemented and screwed three-unit implant-supported fixed dental prostheses (ISFDP) using different implant-abutment horizontal matching configurations (regular vs switching platforms). One hundred and sixty-eight implants with internal hexagon connection (4 mm diameter, 10 mm length, Emfils; Colosso Evolution System, Itú, SP, Brazil) were selected for this study according to the horizontal implant-abutment matching configuration (regular or switching) and retention method and divided in four groups (n = 21 per group) as follows: 1) regular platform cemented (IRC); 2) or screw-retained (IRS); 3) switched-platform cemented (ISC); or 4) screw-retained (ISS). Regular and platform-switched abutments (Colosso evolution, 4 mm and 3.3 mm, respectively) were torqued, and 84 three-unit metal bridges were fabricated (first molar pontic). Implants were embedded in polymethyl-methacrylate resin and subjected to step-stress accelerated life testing in water. Weibull distribution was used to determine the probability of survival for a mission of 100,000 cycles at 400 N (90% two-sided confidence intervals). Polarized light and scanning electron microscopes were used for fractographic analysis. The β values of 0.50, 1.19, 1.25, and 1.95 for groups IRC, IRS, ISC, and ISS respectively, indicated that fatigue accelerated the failure for all groups, except IRC. The cement-retained groups presented significantly higher probability of survival (IRC - 98%, ISC - 59%) than screw-retained groups (IRS - 23% and ISS - 0%). Screw-retained FDPs exclusively failed by abutment-screw fractures, whereas cement-retained presented implant/screw/abutment fractures. The probability of survival of cement-retained ISFDP was higher than screw-retained, irrespective of implant-abutment horizontal configuration. © 2015 Wiley Periodicals, Inc.
Tsaousoglou, Phoebus; Michalakis, Konstantinos; Kang, Kiho; Weber, Hans-Peter; Sculean, Anton
2017-07-01
To assess survival, as well as technical and biological complication rates of partial fixed dental prostheses (FDPs) supported by implants and teeth. An electronic Medline search was conducted to identify articles, published in dental journals from January 1980 to August 2015, reporting on partial FDPs supported by implants and teeth. The search terms were categorized into four groups comprising the PICO question. Manual searches of published full-text articles and related reviews were also performed. The initial database search produced 3587 relevant titles. Three hundred and eighty-six articles were retrieved for abstract review, while 39 articles were selected for full-text review. A total of 10 studies were selected for inclusion. Overall survival rate for implants ranged between 90% and 100%, after follow-up periods with a mean range of 18-120 months. The survival of the abutment teeth was 94.1-100%, while the prostheses survival was 85-100% for the same time period. The most frequent complications were "periapical lesions" (11.53%). The most frequent technical complication was "porcelain occlusal fracture" (16.6%), followed by "screw loosening" (15%). According to the meta-analysis, no intrusion was noted on the rigid connection group, while five teeth (8.19%) were intruded in the non-rigid connection group [95% CI (0.013-0.151)]. The tooth-implant FDP seems to be a possible alternative to an implant-supported FDP. There is limited evidence that rigid connection between teeth and implants presents better results when compared with the non-rigid one. The major drawback of non-rigidly connected FDPs is tooth intrusion. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Battlefield-Acquired Immunogenicity to Metals Affects Orthopaedic Implant Outcome
2015-10-01
dermat itis? Contact Dermatit is 1993;28:15-25. (13) Cramers M, Lucht U. Metal sensitivity in patients treated for tibial fractures with plates of...Zitting A, Jolanki R, Tarvainen K. Nickel release from metals, and a case of allergic contact dermatitis from stainless steel. Contact Dermatit is... Dermat itis 1994;31:249-55. (30) Gawkrodger DJ. Nickel sensitivity and the implantation of orthopaedic prostheses. Contact Dermatit is 1993;28:257 -9
Current indications for stentless aortic bioprostheses.
Hegazy, Yasser Y; Rayan, Amr; Bauer, Stefan; Keshk, Noha; Bauer, Kerstin; Ennker, Ina; Ennker, Jürgen
2018-01-01
The best aortic prostheses have been debated for decades. The introduction of stentless aortic bioprostheses was aimed at improving hemodynamics and potentially the durability of aortic bioprostheses. Despite the good short- and long-term outcomes after implantation of stentless aortic bioprostheses, their use remains limited owing to the technically demanding implantation techniques. Nevertheless, stentless aortic bioprostheses might be of special benefit in certain indications, where they could be a valuable addition to the surgical armamentarium.
Welke, Bastian; Hurschler, Christof; Föller, Marie; Schwarze, Michael; Calliess, Tilman
2013-07-11
Techniques for the skeletal attachment of amputation-prostheses have been developed over recent decades. This type of attachment has only been performed on a small number of patients. It poses various potential advantages compared to conventional treatment with a socket, but is also associated with an increased risk of bone or implant-bone interface fracture in the case of a fall. We therefore investigated the bending stiffness and ultimate bending moment of such devices implanted in human and synthetic bones. Eight human specimens and 16 synthetic models of the proximal femora were implanted with lower extremity prostheses and eight human specimens and six synthetic humeri were implanted with upper extremity prostheses. They were dissected according to typical amputation levels and underwent loading in a material testing machine in a four-point bending setup. Bending stiffness, ultimate bending moment and fracture modes were determined in a load to failure experiment. Additionally, axial pull-out was performed on eight synthetic specimens of the lower extremity. Maximum bending moment of the synthetic femora was 160.6±27.5 Nm, the flexural rigidity of the synthetic femora was 189.0±22.6 Nm2. Maximum bending moment of the human femora was 100.4±38.5 Nm, and the flexural rigidity was 137.8±29.4 Nm2. The maximum bending moment of the six synthetic humeri was 104.9±19.0 Nm, and the flexural rigidity was 63.7±3.6 Nm2. For the human humeri the maximum bending moment was 36.7±11.0 Nm, and the flexural rigidity at was 43.7±10.5 Nm2. The maximum pull-out force for the eight synthetic femora was 3571±919 N. Significant differences were found between human and synthetic specimens of the lower and upper extremity regarding maximum bending moment, bending displacement and flexural rigidity. The results of this study are relevant with respect to previous finding regarding the load at the interfaces of osseointegrated prosthesis fixation devices and are crucial for the development of safety devices intended to protect the bone-implant interface from damaging loadings.
Stiffness and ultimate load of osseointegrated prosthesis fixations in the upper and lower extremity
2013-01-01
Background Techniques for the skeletal attachment of amputation-prostheses have been developed over recent decades. This type of attachment has only been performed on a small number of patients. It poses various potential advantages compared to conventional treatment with a socket, but is also associated with an increased risk of bone or implant-bone interface fracture in the case of a fall. We therefore investigated the bending stiffness and ultimate bending moment of such devices implanted in human and synthetic bones. Methods Eight human specimens and 16 synthetic models of the proximal femora were implanted with lower extremity prostheses and eight human specimens and six synthetic humeri were implanted with upper extremity prostheses. They were dissected according to typical amputation levels and underwent loading in a material testing machine in a four-point bending setup. Bending stiffness, ultimate bending moment and fracture modes were determined in a load to failure experiment. Additionally, axial pull-out was performed on eight synthetic specimens of the lower extremity. Results Maximum bending moment of the synthetic femora was 160.6±27.5 Nm, the flexural rigidity of the synthetic femora was 189.0±22.6 Nm2. Maximum bending moment of the human femora was 100.4±38.5 Nm, and the flexural rigidity was 137.8±29.4 Nm2. The maximum bending moment of the six synthetic humeri was 104.9±19.0 Nm, and the flexural rigidity was 63.7±3.6 Nm2. For the human humeri the maximum bending moment was 36.7±11.0 Nm, and the flexural rigidity at was 43.7±10.5 Nm2. The maximum pull-out force for the eight synthetic femora was 3571±919 N. Conclusion Significant differences were found between human and synthetic specimens of the lower and upper extremity regarding maximum bending moment, bending displacement and flexural rigidity. The results of this study are relevant with respect to previous finding regarding the load at the interfaces of osseointegrated prosthesis fixation devices and are crucial for the development of safety devices intended to protect the bone-implant interface from damaging loadings. PMID:23844992
Acoustic emission studies of posterior stabilized and cruciate retaining knee arthroplasties.
Schwarzkopf, Ran; Kummer, Frederick J; Jaffe, William L
2011-09-01
Different acoustic frequencies have been used to diagnose progression of osteoarthritis, gross pathology, and wear in knee prostheses. It is possible that detailed analysis of higher frequencies could detect and quantify the smaller geometric changes (asperities) that develop in articular prosthetic wear. In this study we evaluated the feasibility of using ultrasonic emission to determine total knee arthroplasty (TKA) type and time from implantation using a simple, handheld measurement system. We examined the ultrasound emission generated by similar designs of posterior stabilized (PS) and cruciate retaining (CR) total knee prostheses and native knees of 58 patients and 10 controls. The subjects were asked to sit, rise, sit again, and take five steps while recording the acoustic data from both knees. Acoustic emission analysis examined frequency distributions and power spectrums of the recorded signals, and their relations to prosthesis type and time from implantation. We screened 44 CR and 48 PS TKAs, as well as 24 native knees. Analysis of this data suggested a possibility of differentiating between type of implants, and a relation to time since implantation. Our data suggest that we might be able to assess the status and time from implantation of a TKA by acoustic emission signals. Further in vitro analysis of the relationship of wear to ultrasonic emission data are needed for accurate quantification of arthroplasty wear. A simple, in-office screening tool for TKA patients could indicate which patients require closer follow-up and monitoring due to risk of potential problems.
Mobbs, Ralph J; Coughlan, Marc; Thompson, Robert; Sutterlin, Chester E; Phan, Kevin
2017-04-01
OBJECTIVE There has been a recent renewed interest in the use and potential applications of 3D printing in the assistance of surgical planning and the development of personalized prostheses. There have been few reports on the use of 3D printing for implants designed to be used in complex spinal surgery. METHODS The authors report 2 cases in which 3D printing was used for surgical planning as a preoperative mold, and for a custom-designed titanium prosthesis: one patient with a C-1/C-2 chordoma who underwent tumor resection and vertebral reconstruction, and another patient with a custom-designed titanium anterior fusion cage for an unusual congenital spinal deformity. RESULTS In both presented cases, the custom-designed and custom-built implants were easily slotted into position, which facilitated the surgery and shortened the procedure time, avoiding further complex reconstruction such as harvesting rib or fibular grafts and fashioning these grafts intraoperatively to fit the defect. Radiological follow-up for both cases demonstrated successful fusion at 9 and 12 months, respectively. CONCLUSIONS These cases demonstrate the feasibility of the use of 3D modeling and printing to develop personalized prostheses and can ease the difficulty of complex spinal surgery. Possible future directions of research include the combination of 3D-printed implants and biologics, as well as the development of bioceramic composites and custom implants for load-bearing purposes.
Penile Prosthesis Implantation in Patients with a History of Total Phallic Construction.
Zuckerman, Jack M; Smentkowski, Katherine; Gilbert, David; Storme, Oscar; Jordan, Gerald; Virasoro, Ramon; Tonkin, Jeremy; McCammon, Kurt
2015-12-01
Outcomes following penile prosthesis implantation in patients with a history of total phallic construction are not well described. The aim of this study was to evaluate outcomes following neophallus penile prosthesis placement. Retrospective review penile prosthesis placement in patients with prior total phallic construction. GORE-TEX® (Gore Medical, Flagstaff, AZ) sleeve neotunica construction was utilized in all patients. Success defined as patient sexual activity with a functioning prosthesis. Thirty-one patients underwent neophallic prosthesis implantation at a mean 35.6 years of age. Prosthesis placement occurred at an average 56.3 months following phallic construction and follow-up was a mean of 59.7 months. Malleable prostheses were placed in 21 patients and inflatable in 10; implants were bilateral in 94%. Six percent experienced operative complications including a bladder injury (1) and phallic flap arterial injury (1). Postoperative complications occurred in 23% at a median 5.5 months following placement. Five prostheses were explanted secondary to infection or erosion and two additional required revisions. Of the explanted prosthesis two were later replaced without further complication. Eighty-one percent of patients were sexually active following prosthesis placement. Penile prosthesis placement is possible in patients with prior penile reconstruction/phallic construction. Although complications rates appear to be elevated in this population compared with historic controls of normal anatomic men, the majority of patients in this series were sexually active following prosthesis placement. This demonstrates the utility of prosthesis implantation in these difficult patients. © 2015 International Society for Sexual Medicine.
NASA Astrophysics Data System (ADS)
Sweitzer, Robyn K.
Retinal prostheses may be used to support patients suffering from Age-related macular degeneration or retinitis pigmentosa. A hermetic encapsulation of the poly(imide )-based prosthesis is important in order to prevent the leakage of water and ions into the electric circuitry embedded in the poly(imide) matrix. The deposition of amorphous aluminum oxide (by sputtering) and diamond like carbon (by pulsed laser ablation and vacuum arc vapor deposition) were studied for the application in retinal prostheses. The resulting thin films were characterized for composition, thickness, adhesion and smoothness by scanning electron microscopy-energy dispersive spectroscopy, atomic force microscopy, profilometry and light microscopy. Electrical stability was evaluated and found to be good. The as-deposited films prevented incursion of salinated fluids into the implant over two (2) three month trials soaking in normal saline at body temperature, Biocompatibility was tested in vivo by implanting coated specimen subretinally in the eye of Yucatan pigs. While amorphous aluminum oxide is more readily deposited with sufficient adhesion quality, biocompatibility studies showed a superior behavior of diamond-like carbon. Amorphous aluminum oxide had more adverse effects and caused more severe damage to the retinal tissue.
New method of fixation of in-bone implanted prosthesis
Pitkin, Mark; Cassidy, Charles; Muppavarapu, Raghuveer; Raymond, James; Shevtsov, Maxim; Galibin, Oleg; Rousselle, Serge D.
2013-01-01
This article presents results on the effectiveness of a new version of the titanium porous composite skin and bone integrated pylon (SBIP). The SBIP is designed for direct skeletal attachment of limb prostheses and was evaluated in a pre-clinical study with three rabbits. In accordance with the study protocol, a new version of the pylon (SBIP-3) was implanted into the hind leg residuum of three rabbits. The SBIP-3 has side fins that are designed to improve the bond between the bone and pylon. The fins are positioned inside two slots precut in the bone walls; their length can be adjusted to match the thickness of the bone walls. After 13 (animal 1) or 26 wk (animals 2 and 3), the animals were sacrificed and samples collected for histopathological analysis. The space between the fins and the bone into which they were fit was filled with fibro-vascular tissue and woven bone. No substantial inflammation was found. We suggest that if further studies substantiate the present results, the proposed method can become an alternative to the established technique of implanting prostheses into the medullar canal of the hosting bone. PMID:24013918
Wear analysis and finishing of bioceramic implant surfaces.
Denkena, Berend; Reichstein, Martin; van der Meer, Marijke; Ostermeier, Sven; Hurschler, Christof
2008-01-01
A primary cause for revision operations of joint replacements is the implant loosening, due to immune reactions resulting from the agglomeration of polyethylene wear debris. Motivated by the successful application of bioceramic materials in hip joint prostheses, a trend towards the development of hard implant materials has occurred. Nonetheless in the area of total knee arthroplasty (TKA), modern efforts have still utilized polyethylene as the tibial-inlay joint component. The use of bioceramic hard-hard-pairings for total knee arthroplasty has been prevented by the complex kinematics and geometries required. Ceramics cannot cope with non-uniform loads, which suggests the need for new designs appropriate to the material. Furthermore, biomechanical requirements should be considered. A rolling-gliding wear simulator, which reproduces the movements and stresses of the knee joint on specimens of simplified geometry, has therefore been developed. High-precision machining processes for free formed bioceramic surfaces, with suitable grinding and polishing tools which adjust to constantly changing contact conditions, are essential. The goal is to put automated finishing in one clamping with five simultaneous controlled axes into practice. The developed manufacturing technologies will allow the advantageous bioceramic materials to be applied and accepted for more complex joint replacements such as knee prostheses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipsey, Ian
In his talk, Shipsey will discuss the cochlear implant, the first device to successfully allow the profoundly deaf to regain some sense of hearing. A cochlear implant is a small electronic apparatus. Unlike a normal hearing aid, which amplifies sound, a cochlear implant is surgically implanted behind the ear where it converts sound waves into electrical impulses. These implants have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. Shipsey will discuss the physiology of natural hearing from the perspective of a physicist. He willmore » also touch on the function of cochlear implants in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. Finally, Shipsey will address the social implications of cochlear implantation and the future outlook for auditory prostheses.« less
Novel synthetic selectively degradable vascular prostheses: a preliminary implantation study.
Izhar, U; Schwalb, H; Borman, J B; Hellener, G R; Hotoveli-Salomon, A; Marom, G; Stern, T; Cohn, D
2001-02-01
Vascular grafts perform less well than autologous arterial or vein grafts. The purpose of this study was to evaluate the short-term performance of selectively biodegradable filament-wound vascular prostheses, comprising elastomeric poly(ether urethane) (Lycra) scaffolds and flexible, hydrophilic biodegradable coatings. Two types of selectively biodegradable vascular grafts were manufactured, comprising a filament-wound Lycra scaffold, subsequently coated with a biodegradable poly(ethylene glycol)/poly(lactic acid) (PELA) block copolymer. The two types of grafts differed in both the overall porosity of the scaffold and the hydrophilicity of the biodegradable constituent. A 60-mm-long and 6-mm-diameter filament-wound and polytetrafluoroethylene (ePTFE) grafts were implanted as interposition prostheses, randomly, at the right- and left-side carotid arteries. Implantation studies proved the grafts to be patent and pulsatile for periods of up to 3 months. Increasing the scaffold porosity and enhancing the hydrophilicity of the biodegradable component improved both the transmural tissue ingrowth process and the vascularization of the prosthesis wall. Also, a well-adhered peripheral tissue and a thin, uniform intima and endothelial lining were obtained. All ePTFE graft controls, although patent, were rather stiff and nonpulsatile. A thick pseudointima, poorly attached to the prosthesis inner surface, was observed. The compliance of the wet grafts was significantly higher than in the dry state, stemming mainly from the water-plasticizing effect on the biodegradable component. The grafts explanted after a period of 6 weeks exhibited compliance only slightly lower than that of the wet grafts. After 12 weeks, however, the hoop compliance was 20% lower than that prior to implantation. At 100 mm Hg, for example, the original compliance of the wet graft was 2.5%/100 mm Hg decreasing to 2.0%/100 mm Hg after a 3-month implantation. The compliance reduction with implantation is attributed to the ingrowth of the perigraft tissue as revealed by the histological study. A compliance of 2.0%/100 mm Hg is slightly better than that of a standard PTFE graft with an original compliance of 1.6%/100 mm Hg. Yet it is still an order of magnitude smaller than that of a canine carotid artery. The improved mechanical properties and enhanced healing of the highly porous filament-wound Lycra scaffold graft coated with hydrophilic biodegradable PELA has the potential of being a highly effective small caliber prosthetic graft. Copyright 2000 Academic Press.
A computational method for comparing the behavior and possible failure of prosthetic implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nielsen, C.; Hollerbach, K.; Perfect, S.
1995-05-01
Prosthetic joint implants currently in use exhibit high Realistic computer modeling of prosthetic implants provides an opportunity for orthopedic biomechanics researchers and physicians to understand possible in vivo failure modes, without having to resort to lengthy and costly clinical trials. The research presented here is part of a larger effort to develop realistic models of implanted joint prostheses. The example used here is the thumb carpo-metacarpal (cmc) joint. The work, however, can be applied to any other human joints for which prosthetic implants have been designed. Preliminary results of prosthetic joint loading, without surrounding human tissue (i.e., simulating conditions undermore » which the prosthetic joint has not yet been implanted into the human joint), are presented, based on a three-dimensional, nonlinear finite element analysis of three different joint implant designs.« less
A descriptive study of the radiographic density of implant restorative cements.
Wadhwani, Chandur; Hess, Timothy; Faber, Thomas; Piñeyro, Alfonso; Chen, Curtis S K
2010-05-01
Cementation of implant prostheses is a common practice. Excess cement in the gingival sulcus may harm the periodontal tissues. Identification of the excess cement may be possible with the use of radiographs if the cement has sufficient radiopacity. The purpose of this study was to compare the radiographic density of different cements used for implant prostheses. Eight different cements were compared: TempBond Original (TBO), TempBond NE (TBN), Fleck's (FL), Dycal (DY), RelyX Unicem (RXU), RelyX Luting (RXL), Improv (IM), and Premier Implant Cement (PIC). Specimen disks, 2 mm in thickness, were radiographed. Images were made using photostimulable phosphor (PSP) plates with standardized exposure values. The average grey level of the central area of each specimen disk was selected and measured in pixels using a software analysis program, ImageTool, providing an average grey level value representative of radiodensity for each of the 8 cements. The radiodensity was determined using the grey level values of the test materials, which were recorded and compared to a standard aluminum step wedge. An equivalent thickness of aluminum in millimeters was calculated using best straight line fit estimates. To assess contrast effects by varying the exposure settings, a second experiment using 1-mm-thick cement specimens radiographed at both 60 kVp and 70 kVp was conducted. The PSP plates with specimens were measured for a grey level value comparison to the standard aluminum step wedge, using the same software program. The highest grey level values were recorded for the zinc cements (TBO, TBN, and FL), with the 1-mm specimen detectable at both 60- and 70-kVp settings. A lower grey level was recorded for DY, indicative of a lower radiodensity compared to the zinc cements, but higher than RXL and RXU. The implant-specific cements had the lowest grey level values. IM could only be detected in 2-mm-thick sections with a lower aluminum equivalence value than the previously mentioned cements. PIC could not be detected radiographically for either the 1-mm or 2-mm thicknesses at either of the kVp settings. Some types of cement commonly used for the cementation of implant-supported prostheses have poor radiodensity and may not be detectable following radiographic examination.
Krennmair, Gerald; Seemann, Rudolf; Fazekas, Andres; Ewers, Rolf; Piehslinger, Eva
2012-01-01
To determine patient satisfaction and preference for implant-supported mandibular overdentures (IOD) retained with ball or Locator attachments. In addition, peri-implant conditions and prosthodontic maintenance efforts for the final attachments were evaluated after 1 year of function. In this crossover clinical trial, 20 edentulous patients were recruited to receive two mandibular implants in the canine region and were provided with implant-retained mandibular overdentures and new complete maxillary dentures. Implant-retained mandibular overdentures were stabilized with either ball attachments or Locator attachments, in random order. After 3 months of function, the attachments in the existing denture were changed. Questionnaires on satisfaction/complaints with the prostheses were administered at baseline (with the old dentures) and after 3 months of function with each attachment, thus providing for an intraindividual comparison. The decision for the final attachment chosen was based on the patient's preference. For the definitive attachment, peri-implant conditions (peri-implant marginal bone resorption, pocket depth, and Plaque Index, Gingival Index, and Bleeding Index) as well as prosthodontic maintenance efforts and satisfaction score were evaluated after an insertion period of 1 year. Nineteen (95%) patients completed the study (1 dropout). Patient satisfaction improved significantly (P<.05) from baseline (old dentures) to the new prostheses retained with each of the two attachment types for all domains of satisfaction. However, there were no differences between ball or Locator attachment for any items of satisfaction evaluated and neither attachment had a significant patient preference. No differences for peri-implant parameters or for patient satisfaction were noted between the definitive attachments (ball, n=10; Locator, n=9) after 1 year. Although the overall incidence rate of prosthodontic maintenance did not significantly differ between both retention modalities, the Locator attachment required more postinsertion aftercare (activation of retention) than the ball anchors.
A system verification platform for high-density epiretinal prostheses.
Chen, Kuanfu; Lo, Yi-Kai; Yang, Zhi; Weiland, James D; Humayun, Mark S; Liu, Wentai
2013-06-01
Retinal prostheses have restored light perception to people worldwide who have poor or no vision as a consequence of retinal degeneration. To advance the quality of visual stimulation for retinal implant recipients, a higher number of stimulation channels is expected in the next generation retinal prostheses, which poses a great challenge to system design and verification. This paper presents a system verification platform dedicated to the development of retinal prostheses. The system includes primary processing, dual-band power and data telemetry, a high-density stimulator array, and two methods for output verification. End-to-end system validation and individual functional block characterization can be achieved with this platform through visual inspection and software analysis. Custom-built software running on the computers also provides a good way for testing new features before they are realized by the ICs. Real-time visual feedbacks through the video displays make it easy to monitor and debug the system. The characterization of the wireless telemetry and the demonstration of the visual display are reported in this paper using a 256-channel retinal prosthetic IC as an example.
Graves, Stephen; Sedrakyan, Art; Baste, Valborg; Gioe, Terence J; Namba, Robert; Martínez Cruz, Olga; Stea, Susanna; Paxton, Elizabeth; Banerjee, Samprit; Isaacs, Abby J; Robertsson, Otto
2014-12-17
Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Retention Strength of Conical Welding Caps for Fixed Implant-Supported Prostheses.
Nardi, Diego; Degidi, Marco; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio
This study evaluated the retention strength of welding caps for Ankylos standard abutments using a pull-out test. Each sample consisted of an implant abutment and its welding cap. The tests were performed with a Zwick Roell testing machine with a 1-kN load cell. The retention strength of the welding caps increased with higher abutment diameters and higher head heights and was comparable or superior to the values reported in the literature for the temporary cements used in implant dentistry. Welding caps provide a reliable connection between an abutment and a fixed prosthesis without the use of cement.
Saragaglia, Dominique; Bevand, Adrien; Refaie, Ramsay; Rubens-Duval, Brice; Pailhé, Régis
2018-05-01
The purpose of this study was to present the results of the KAPS® uni knee arthroplasty system, both mobile and fixed bearing with reference to function, alignment and complications in 103 implants with a mean follow-up of nine years. This was a retrospective study of 103 unicompartimental knee arthroplasties in 89 patients operated on between March 2005 and March 2010. The population was composed of 50 males and 39 females, with a mean age of 70.5 ± 7.5 years (41 - 90). Eighty-seven patients had a genu varum deformity (84.5%), one of whom had an osteoid osteoma of the lateral tibial plateau and 16 patients had a genu valgum (15.5%). Eighty-six medial prostheses were implanted (82 mobile bearings and 4 fixed bearings) and 17 lateral prostheses (all fixed bearings) including the osteoid osteoma. At a mean follow-up of 107.5 months (73-138), 72 knees (58 patients) were reviewed (70%). The mean IKS score was of 173 ± 31 points (58 - 200). The mean Oxford knee score was 21 ± 8 points (12 - 50). The cumulated survival rate at a follow up of 132 months was 98.2%. The KAPS® unicompartmental knee arthroplasty gives efficacious and safe outcomes in the majority of cases at a mean follow-up of nine years. The availability of both fixed and mobile bearings with the same instrumentation, allowing to choose the right implant intra-operatively, is a great advantage in order to avoid the occurrence of some complications, specific to mobile bearing prostheses (dislocation and over-correction).
1997-06-10
been in the area of implantology . Recent advances in dental titanium casting machines allow for the use of titanium for crowns, fixed partial dentures...medical implant prostheses (McKinney and Lemons, 1985; Williams, 1981). By the end of the 1960s, titanium found a niche in dental implantology ...as an implant or restorative material. In the field of dental implantology , evidence suggests that metal corrosion and allergenicity may be important
Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.
Bleiziffer, Sabine; Hettich, Ina; Hutter, Andrea; Wagner, Anke; Deutsch, Marcus-André; Piazza, Nicolo; Lange, Rüdiger
2013-05-01
The study aim was to investigate the incidence of patient-prosthesis mismatch (PPM) with new catheter valves, and its influence on the patients' clinical state. At present, few echocardiographic data are available on the incidence and impact of PPM with the CoreValve and Sapien prostheses for transcatheter aortic valve implantation (TAVI). The reliability of effective orifice area (EOA) measurements was assured by awaiting an interval of six months after TAVI. Of 256 survivors after TAVI, 149 complete echocardiographic data sets were available for the assessment of the indexed EOA (iEOA). In total, 106 CoreValve prostheses and 43 Sapien prostheses were implanted in this high-risk cohort (mean age 81 +/- 6 years, mean logistic EuroSCORE 20 +/- 13%). The overall incidence of PPM (iEOA < 0.85 cm2/m2) was 61%. Patients with a larger body surface area were more likely to develop PPM (p = 0.001), while the prosthesis type, native annulus diameter, preoperative EOA, gender and prosthesis size had no influence. The mean aortic gradient was significantly higher in patients with PPM. A reduction in the left ventricular end-diastolic diameter was seen in all patients, without significant differences between groups. There were no differences in postoperative NYHA class or self-assessed health state between patients with or without PPM. PPM was common after TAVI in the presented cohort, presumably because the native calcium masses narrow the outflow area available for blood flow. As expected for low gradients, there was no impairment of left ventricular dimension regression or clinical state of the patients, even if severe PPM was present. Based on the presented data, it is assumed that PPM might be less relevant in TAVI patients.
Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing.
Abdel-Jaber, Sami; Belvedere, Claudio; Leardini, Alberto; Affatato, Saverio
2015-11-05
Knee wear simulators are meant to perform load cycles on knee implants under physiological conditions, matching exactly, if possible, those experienced at the replaced joint during daily living activities. Unfortunately, only conditions of low demanding level walking, specified in ISO-14243, are used conventionally during such tests. A recent study has provided a consistent knee kinematic and load data-set measured during stair climbing in patients implanted with a specific modern total knee prosthesis design. In the present study, wear simulation tests were performed for the first time using this data-set on the same prosthesis design. It was hypothesised that more demanding tasks would result in wear rates that differ from those observed in retrievals. Four prostheses for total knee arthroplasty were tested using a displacement-controlled knee wear simulator for two million cycles at 1.1 Hz, under kinematics and load conditions typical of stair climbing. After simulation, the corresponding damage scars on the bearings were qualified and compared with equivalent explanted prostheses. An average mass loss of 20.2±1.5 mg was found. Scanning digital microscopy revealed similar features, though the explant had a greater variety of damage modes, including a high prevalence of adhesive wear damage and burnishing in the overall articulating surface. This study confirmed that the results from wear simulation machines are strongly affected by kinematics and loads applied during simulations. Based on the present results for the full understanding of the current clinical failure of knee implants, a more comprehensive series of conditions are necessary for equivalent simulations in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.
Antibiotic cements in articular prostheses: current orthopaedic concepts.
Langlais, F; Belot, N; Ropars, M; Thomazeau, H; Lambotte, J C; Cathelineau, G
2006-08-01
The possibilities and limits of antibiotic cements (ACs) have been assessed by many researchers. ACs are now approved by many drug agencies, including the US Food and Drug Administration (approval in 2003), with widespread use in prophylaxis and curative treatments. Laboratory experiments have achieved satisfactory antibiotic delivery without impairing the mechanical properties of ACs. Implantation in large animals (e.g. sheep) showed an antibiotic concentration in the bone cortex four times the minimal inhibitory concentration (MIC) 6 months after implantation. Human pharmacokinetics during total hip replacement (THR) show antibiotic concentrations 20 times the MIC in drainage fluids. No toxic concentrations have been detected in blood or urine, and no allergies, toxic effects, mechanical failures or selection of resistant microorganisms have been observed. Antibioprophylaxis has been assessed in prospective studies in over 1600 cases. In data from the Scandinavian arthroplasty registers, with an exhaustive follow-up of more than 240000 THRs, infection rate was reduced by ca. 50% (0.9% compared with 1.9%). In prostheses with severe infection, use of AC increases the infection control rate from 86% to 93% when using two-stage prosthetic exchanges. In moderate infection, a similar infection control rate (86%) was achieved either by two-stage exchange without local antibiotic or by one-stage exchange with AC; however, one-stage exchange achieved better functional results at lower cost and with reduced pain and hospital stay. Therefore, AC prophylaxis is widely used in countries with prostheses registers (Northern Europe), and use of ACs as treatment for infected prostheses is often considered as the gold standard in the EU and North America. However, AC is only an adjuvant treatment, and excision of infected and devascularized tissues as well as systemic antibiotic treatment managed by a multidisciplinary team remain the main factors of infection control.
Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.
Goo, Chui Ling; Tan, Keson Beng Choon
2017-01-01
This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
Comparison between implant-supported prostheses and teeth regarding passive threshold level.
Jacobs, R; van Steenberghe, D
1993-01-01
A passive threshold determination was carried out on 31 patients subdivided into four test groups according to different prosthesis types supported by osseointegrated implants. They were compared to a control group of 10 patients with nonrestored natural test teeth. Forces were generated by a solenoid-driven stimulating device, which was placed in contact with the implant or tooth prior to the actual force rise to avoid impact forces. The findings indicate that the threshold level of implants is 50 times higher than that of natural teeth when tapping is avoided, which might otherwise trigger distant receptors. Bone deformation triggering the periosteal mechanoreceptors is the most logical explanation for the sensation reported.
Clinical experience with fibrin glue in cardiac surgery.
Köveker, G; de Vivie, E R; Hellberg, K D
1981-10-01
Cardiac surgery is often associated with hemostatic abnormalities leading to severe bleeding. Special problems are to be expected, if prosthetic material has to be implanted. Preclotting of Dacron prostheses with blood is well established but failures are sometimes encountered. Several years ago a new hemostatic sealing system (fibrin glue) was introduced into therapy. Since 1978 fibrin glue has been applied in 176 patients. The indications were: 1. sealing of woven Dacron prostheses, 2. bleeding from suture-holes (Gore-Tex), 3. diffuse myocardial bleeding and 4. prevention of kinking of coronary artery grafts. In 32 patients with an aortoventriculoplasty operation using Dacron the "blood preclotting" and "fibrin sealing" methods were compared. In the fibrin glue group there was a significant reduction in postoperative blood loss as well as a shortening of the operation time (period of protamin administration to skin closure). No fibrinolytic dissolution of the fibrin layer on the prostheses was observed.
Simplified Design Equations for Class-E Neural Prosthesis Transmitters
Troyk, Philip; Hu, Zhe
2013-01-01
Extreme miniaturization of implantable electronic devices is recognized as essential for the next generation of neural prostheses, owing to the need for minimizing the damage and disruption of the surrounding neural tissue. Transcutaneous power and data transmission via a magnetic link remains the most effective means of powering and controlling implanted neural prostheses. Reduction in the size of the coil, within the neural prosthesis, demands the generation of a high-intensity radio frequency magnetic field from the extracoporeal transmitter. The Class-E power amplifier circuit topology has been recognized as a highly effective means of producing large radio frequency currents within the transmitter coil. Unfortunately, design of a Class-E circuit is most often fraught by the need to solve a complex set of equations so as to implement both the zero-voltage-switching and zero-voltage-derivative-switching conditions that are required for efficient operation. This paper presents simple explicit design equations for designing the Class-E circuit topology. Numerical design examples are presented to illustrate the design procedure. PMID:23292784
Surke, Carsten; Ducommun Dit Boudry, Pascal; Vögelin, Esther
2015-08-01
The loss of the upper extremity implicates a grave insult in the life of the involved person. To compensate for the loss of function different powered prosthetic devices are available. Ever since their first development 70 years ago numerous improvements in terms of size, weight and wearing comfort have been developed, but issues regarding the control of upper extremity prostheses remain. Slow grasping speed, limited grip positions and especially failure to provide a sensory feedback limit the acceptance in patients. Recent developments are aimed to allow a more intuitive control of the prosthetic device and to provide a sensory feedback to the amputee. Targeted reinnervation reassignes existing muscles to different peripheral nerves thereby enabling them to fulfill alternate functions. Implanting electrodes into muscle bellies of the forearm allows a more accurate control of the prosthesis. Promising results are being achieved by implanting nerve electrodes by establishing bilateral communication between patient and prosthesis. The following review summarizes the current developments of bionic prostheses in the upper extremity.
GASTALDI, G.; PALUMBO, L.; MORESCHI, C.; GHERLONE, E.F.; CAPPARÉ, P.
2017-01-01
SUMMARY Introduction The aim of this study is to determine the outcome of maxillofacial prosthetic rehabilitation after oncological resections, including both intra- and extra-oral prosthetic devices. Methods In this study were included 72 patients, who have undergone an intra or extra-oral maxillofacial prosthetic rehabilitation after an oncologic resection. Tumors on the head and neck were analyzed and the defects of these resections have been divided in two different groups: intra and extra-oral defects. Results 72 participants were treated with maxillofacial prosthesis, 3 of which with post-traumatic wounds and 69 with resections of tumors on the head and neck. Of the 69 treated for neoplastic disease, 43 received an intraoral prosthesis (palatal obturator) and 29 with an extraoral epithesis (18 with nasal prostheses, 8 with orbital implants and 3 with ear implants). The group included patients with different types of tumors. All the patients were evaluated in terms of aesthetic appearance after the construction of the prostheses and the results were satisfactory. Conclusion Within the limitations of this study, after the use of maxillofacial protheses patients feel more confident and self-assured. Maxillofacial protheses are a good solution in order to improve the life’s quality in patients with tumors resections: prostheses are easy to handle and provide a satisfying social interaction for the patients. PMID:29285330
NASA Astrophysics Data System (ADS)
Fink, Wolfgang; You, Cindy X.; Tarbell, Mark A.
2010-01-01
It is difficult to predict exactly what blind subjects with camera-driven visual prostheses (e.g., retinal implants) can perceive. Thus, it is prudent to offer them a wide variety of image processing filters and the capability to engage these filters repeatedly in any user-defined order to enhance their visual perception. To attain true portability, we employ a commercial off-the-shelf battery-powered general purpose Linux microprocessor platform to create the microcomputer-based artificial vision support system (μAVS2) for real-time image processing. Truly standalone, μAVS2 is smaller than a deck of playing cards, lightweight, fast, and equipped with USB, RS-232 and Ethernet interfaces. Image processing filters on μAVS2 operate in a user-defined linear sequential-loop fashion, resulting in vastly reduced memory and CPU requirements during execution. μAVS2 imports raw video frames from a USB or IP camera, performs image processing, and issues the processed data over an outbound Internet TCP/IP or RS-232 connection to the visual prosthesis system. Hence, μAVS2 affords users of current and future visual prostheses independent mobility and the capability to customize the visual perception generated. Additionally, μAVS2 can easily be reconfigured for other prosthetic systems. Testing of μAVS2 with actual retinal implant carriers is envisioned in the near future.
Fink, Wolfgang; You, Cindy X; Tarbell, Mark A
2010-01-01
It is difficult to predict exactly what blind subjects with camera-driven visual prostheses (e.g., retinal implants) can perceive. Thus, it is prudent to offer them a wide variety of image processing filters and the capability to engage these filters repeatedly in any user-defined order to enhance their visual perception. To attain true portability, we employ a commercial off-the-shelf battery-powered general purpose Linux microprocessor platform to create the microcomputer-based artificial vision support system (microAVS(2)) for real-time image processing. Truly standalone, microAVS(2) is smaller than a deck of playing cards, lightweight, fast, and equipped with USB, RS-232 and Ethernet interfaces. Image processing filters on microAVS(2) operate in a user-defined linear sequential-loop fashion, resulting in vastly reduced memory and CPU requirements during execution. MiccroAVS(2) imports raw video frames from a USB or IP camera, performs image processing, and issues the processed data over an outbound Internet TCP/IP or RS-232 connection to the visual prosthesis system. Hence, microAVS(2) affords users of current and future visual prostheses independent mobility and the capability to customize the visual perception generated. Additionally, microAVS(2) can easily be reconfigured for other prosthetic systems. Testing of microAVS(2) with actual retinal implant carriers is envisioned in the near future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, W; Merrick, G; Kurko, B
Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from themore » phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible.« less
Khuder, Tameem; Yunus, Norsiah; Sulaiman, Eshamsul; Dabbagh, Ali
2017-11-01
Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hao, Shiying; Gorjon, Jose; Taylor, Stephen
2014-03-01
This work describes the functions of the external, portable part of a telemetry system for powering and interrogating implantable electrical devices built within orthopaedic implants for real-time data acquisition of strain, load, temperature, humidity and other relevant data (e.g. from inertial sensors). The system contains a battery powered inductive energiser and demodulator to remotely power the implant electronics and demodulate the signals transmitted from the implanted device. Due to the housing of the internal coil, sufficient inductive coupling is obtained between the external and internal tuned circuits to enable simultaneous power and data transmission over the same inductive link. The actual performance of this system when used with one specific implant was studied, and some correspondence made to the relevant theory. Performance factors relating to both power efficiency and data reconstruction were identified. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Primo, Bruno Tochetto; Mezzari, Leonardo Marcos; da Fontoura Frasca, Luís Carlos; Linderman, Raquel; Rivaldo, Elken Gomes
To evaluate and compare the clinical and radiographic outcomes of mandibular rehabilitation with fixed prostheses on three implants with immediate versus delayed loading. The sample comprised 21 patients who underwent treatment with immediate loading and 23 who received delayed loading. All had worn their prostheses for at least 18 months. Radiographic evaluation of bone loss was carried out in Adobe Photoshop CS5 by a single calibrated examiner using digitized panoramic radiographs. Clinical examination of the technical conditions of the prosthetic device assessed the condition of the acrylic resin base, dental occlusion, metal framework, presence of cover screws, screw fixation of the prosthesis and abutments, length of cantilever (effort) and resistance arms, presence of plaque on prosthetic abutments, and hygiene of the prosthesis. One implant failed in each group, resulting in a 95.23% treatment success rate with immediate loading and 95.65% with delayed loading (no statistically significant between-group difference). In the immediate-loading group, the mean bone loss was 1.96 ± 0.73 mm around central implants and 1.64 ± 0.84 mm at distal implants. In the delayed-loading group, the mean bone loss was 1.85 ± 0.67 mm around central implants and 1.70 ± 0.77 mm at distal implants. According to Student t test, there was no significant within-group difference in bone loss and no difference between the immediate-loading and delayed-loading groups. The only prosthesis-related complications that differed significantly between groups were "condition of the acrylic base," "occlusion," and "presence of right cover screw." There was no statistically significant association of lever arm ratio with peri-implant bone loss or bone loss on the mesial surfaces compared to the distal surfaces of the distal implants. The three-implant-supported fixed prosthesis protocol tested in this study proved to be a viable therapeutic strategy for mandibular edentulous patients with maxillary complete dentures, regardless of whether loading was immediate or delayed, with no difference in peri-implant bone loss.
Papsin, Blake C.; Paludetti, Gaetano; Gordon, Karen A.
2015-01-01
Children using unilateral cochlear implants abnormally rely on tempo rather than mode cues to distinguish whether a musical piece is happy or sad. This led us to question how this judgment is affected by the type of experience in early auditory development. We hypothesized that judgments of the emotional content of music would vary by the type and duration of access to sound in early life due to deafness, altered perception of musical cues through new ways of using auditory prostheses bilaterally, and formal music training during childhood. Seventy-five participants completed the Montreal Emotion Identification Test. Thirty-three had normal hearing (aged 6.6 to 40.0 years) and 42 children had hearing loss and used bilateral auditory prostheses (31 bilaterally implanted and 11 unilaterally implanted with contralateral hearing aid use). Reaction time and accuracy were measured. Accurate judgment of emotion in music was achieved across ages and musical experience. Musical training accentuated the reliance on mode cues which developed with age in the normal hearing group. Degrading pitch cues through cochlear implant-mediated hearing induced greater reliance on tempo cues, but mode cues grew in salience when at least partial acoustic information was available through some residual hearing in the contralateral ear. Finally, when pitch cues were experimentally distorted to represent cochlear implant hearing, individuals with normal hearing (including those with musical training) switched to an abnormal dependence on tempo cues. The data indicate that, in a western culture, access to acoustic hearing in early life promotes a preference for mode rather than tempo cues which is enhanced by musical training. The challenge to these preferred strategies during cochlear implant hearing (simulated and real), regardless of musical training, suggests that access to pitch cues for children with hearing loss must be improved by preservation of residual hearing and improvements in cochlear implant technology. PMID:26317976
Giannantonio, Sara; Polonenko, Melissa J; Papsin, Blake C; Paludetti, Gaetano; Gordon, Karen A
2015-01-01
Children using unilateral cochlear implants abnormally rely on tempo rather than mode cues to distinguish whether a musical piece is happy or sad. This led us to question how this judgment is affected by the type of experience in early auditory development. We hypothesized that judgments of the emotional content of music would vary by the type and duration of access to sound in early life due to deafness, altered perception of musical cues through new ways of using auditory prostheses bilaterally, and formal music training during childhood. Seventy-five participants completed the Montreal Emotion Identification Test. Thirty-three had normal hearing (aged 6.6 to 40.0 years) and 42 children had hearing loss and used bilateral auditory prostheses (31 bilaterally implanted and 11 unilaterally implanted with contralateral hearing aid use). Reaction time and accuracy were measured. Accurate judgment of emotion in music was achieved across ages and musical experience. Musical training accentuated the reliance on mode cues which developed with age in the normal hearing group. Degrading pitch cues through cochlear implant-mediated hearing induced greater reliance on tempo cues, but mode cues grew in salience when at least partial acoustic information was available through some residual hearing in the contralateral ear. Finally, when pitch cues were experimentally distorted to represent cochlear implant hearing, individuals with normal hearing (including those with musical training) switched to an abnormal dependence on tempo cues. The data indicate that, in a western culture, access to acoustic hearing in early life promotes a preference for mode rather than tempo cues which is enhanced by musical training. The challenge to these preferred strategies during cochlear implant hearing (simulated and real), regardless of musical training, suggests that access to pitch cues for children with hearing loss must be improved by preservation of residual hearing and improvements in cochlear implant technology.
Materials and technologies for soft implantable neuroprostheses
NASA Astrophysics Data System (ADS)
Lacour, Stéphanie P.; Courtine, Grégoire; Guck, Jochen
2016-10-01
Implantable neuroprostheses are engineered systems designed to restore or substitute function for individuals with neurological deficits or disabilities. These systems involve at least one uni- or bidirectional interface between a living neural tissue and a synthetic structure, through which information in the form of electrons, ions or photons flows. Despite a few notable exceptions, the clinical dissemination of implantable neuroprostheses remains limited, because many implants display inconsistent long-term stability and performance, and are ultimately rejected by the body. Intensive research is currently being conducted to untangle the complex interplay of failure mechanisms. In this Review, we emphasize the importance of minimizing the physical and mechanical mismatch between neural tissues and implantable interfaces. We explore possible materials solutions to design and manufacture neurointegrated prostheses, and outline their immense therapeutic potential.
NASA Astrophysics Data System (ADS)
Corrêa, Cássia B.; Ramos, Nuno V.; Monteiro, Jaime; Vaz, Luis G.; Vaz, Mario A. P.
2012-10-01
The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.
Implant support for removable partial overdentures: a case report.
Halterman, S M; Rivers, J A; Keith, J D; Nelson, D R
1999-01-01
Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for complex courses of treatment that include dental implants requires close coordination between the surgeon and the restorative dentist. Decisions that deal with type, location, size, number of implant fixtures, and design of the prosthesis are critical. All of these areas must be discussed and established as acceptable to the patient and each clinician before the initiation of treatment. In this report, we present a course of patient treatment in which a removable partial denture is supported by natural remaining teeth in conjunction with osseointegrated implants.
Antonini, Gabriele; Vicini, Patrizio; De Berardinis, Ettore; Pacchiarotti, Arianna; Gentile, Vincenzo; Perito, Paul
2016-01-14
Fibrolipomas are an infrequent type of lipomas. We describe a case of a man suffering from subcutaneous penile fibrolipoma, who twelve months earlier has been submitted to augmentative phalloplasty due to aesthetic dysmorphophobia. The same patient three years earlier has been submitted to three-component hydraulic penile prostheses implantation due to erectile dysfunction. After six months from removing of the mass, the penile elongation and penile enlargement were stable, the prostheses were correctly functioning and the patient was satisfied with his sexual intercourse and life. The diagnostics and surgical characteristics of this case are reported.
Stemless shoulder arthroplasty: a literature review
PETRICCIOLI, DARIO; BERTONE, CELESTE; MARCHI, GIACOMO
2015-01-01
The design of humeral implants for shoulder arthroplasty has evolved over the years. The new-generation modular shoulder prostheses have an anatomical humeral stem that replicates the three-dimensional parameters of the proximal humerus. An anatomical reconstruction is the best way to restore stability and mobility of the prosthetic shoulder and improve implant durability. However, a perfect anatomical match is not always possible in, for example, patients with post-traumatic osteoarthritis of the shoulder and deformities in the metaphyseal region. To avoid stem-related complications while retaining the advantages of the fourth generation of shoulder implants, different stemless implants have been developed. The stemless shoulder prosthesis is a new concept in shoulder arthroplasty. The authors review the indications, surgical technique, clinical and radiological midterm results, and complications of these humeral implants. PMID:26151038
Intravalvular Implantation of Mitral Valve Prostheses
Cooley, Denton A.; Ingram, Michael T.
1987-01-01
We describe a technique of intravalvular implantation of a low-profile prosthesis that has been used in nine patients with mitral valve lesions. This technique preserves the anterior and posterior chordae and papillary mechanisms, which may decrease the incidence of postoperative left ventricular dysfunction that has been noted following standard mitral valve replacement. The technique may also be useful in some patients with aortic and tricuspid regurgitation when the annulus and leaflets are relatively normal pathologically. (Texas Heart Institute Journal 1987;14:188-193) PMID:15229740
Rico-Nieto, A; Moreno-Ramos, F; Fernández-Baillo, N
2018-04-07
There are increasingly more patients with prosthetic implants (orthopaedic prostheses, lumbar instruments, osteosynthesis material). In the last decade, infections caused by carbapenem resistant Enterobacteriaceae have increased (bacteriaemia, abscesses, urinary tract infections...) with great difficulty in treatment and important associated comorbidity. We present the first case of infection of a lumbar instrumentation by Klebsiella pneumoniae producing carbapenemase D, OXA-48 type, and successfully treated. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
EDITORIAL: Focus on the neural interface Focus on the neural interface
NASA Astrophysics Data System (ADS)
Durand, Dominique M.
2009-10-01
The possibility of an effective connection between neural tissue and computers has inspired scientists and engineers to develop new ways of controlling and obtaining information from the nervous system. These applications range from `brain hacking' to neural control of artificial limbs with brain signals. Notwithstanding the significant advances in neural prosthetics in the last few decades and the success of some stimulation devices such as cochlear prosthesis, neurotechnology remains below its potential for restoring neural function in patients with nervous system disorders. One of the reasons for this limited impact can be found at the neural interface and close attention to the integration between electrodes and tissue should improve the possibility of successful outcomes. The neural interfaces research community consists of investigators working in areas such as deep brain stimulation, functional neuromuscular/electrical stimulation, auditory prostheses, cortical prostheses, neuromodulation, microelectrode array technology, brain-computer/machine interfaces. Following the success of previous neuroprostheses and neural interfaces workshops, funding (from NIH) was obtained to establish a biennial conference in the area of neural interfaces. The first Neural Interfaces Conference took place in Cleveland, OH in 2008 and several topics from this conference have been selected for publication in this special section of the Journal of Neural Engineering. Three `perspectives' review the areas of neural regeneration (Corredor and Goldberg), cochlear implants (O'Leary et al) and neural prostheses (Anderson). Seven articles focus on various aspects of neural interfacing. One of the most popular of these areas is the field of brain-computer interfaces. Fraser et al, report on a method to generate robust control with simple signal processing algorithms of signals obtained with electrodes implanted in the brain. One problem with implanted electrode arrays, however, is that they can fail to record reliably neural signals for long periods of time. McConnell et al show that by measuring the impedance of the tissue, one can evaluate the extent of the tissue response to the presence of the electrode. Another problem with the neural interface is the mismatch of the mechanical properties between electrode and tissue. Basinger et al use finite element modeling to analyze this mismatch in retinal prostheses and guide the design of new implantable devices. Electrical stimulation has been the method of choice to activate externally the nervous system. However, Zhang et al show that a novel dual hybrid device integrating electrical and optical stimulation can provide an effective interface for simultaneous recording and stimulation. By interfacing an EMG recording system and a movement detection system, Johnson and Fuglevand develop a model capable of predicting muscle activity during movement that could be important for the development of motor prostheses. Sensory restoration is another unsolved problem in neural prostheses. By developing a novel interface between the dorsal root ganglia and electrodes arrays, Gaunt et al show that it is possible to recruit afferent fibers for sensory substitution. Finally, by interfacing directly with muscles, Jung and colleagues show that stimulation of muscles involved in locomotion following spinal cord damage in rats can provide an effective treatment modality for incomplete spinal cord injury. This series of articles clearly shows that the interface is indeed one of the keys to successful therapeutic neural devices. The next Neural Interfaces Conference will take place in Los Angeles, CA in June 2010 and one can expect to see new developments in neural engineering obtained by focusing on the neural interface.
3D hybrid electrode structure as implantable interface for a vestibular neural prosthesis in humans.
Hoffmann, Klaus-P; Poppendieck, Wigand; Tätzner, Simon; DiGiovanna, Jack; Kos, Maria Izabel; Guinand, Nils; Guyot, Jean-P; Micera, Silvestro
2011-01-01
Implantable interfaces are essential components of vestibular neural prostheses. They interface the biological system with electrical stimulation that is used to restore transfer of vestibular information. Regarding the anatomical situation special 3D structures are required. In this paper, the design and the manufacturing process of a novel 3D hybrid microelectrode structure as interface to the human vestibular system are described. Photolithography techniques, assembling technology and rapid prototyping are used for manufacturing.
Castus, P; Heymans, O; Melin, P; Renwart, L; Henrist, C; Hayton, E; Mordon, S; Leclère, F M
2018-04-01
The reinsertion of an infected implant when peri-prosthetic infection occurs early after breast augmentation or breast reconstruction remains controversial. In this experimental study, the authors tried to remove bacteria, and their biofilm, from the colonized surface of breast prostheses, without damaging their integrity. A total of 112 shell samples of silicone breast prostheses, smooth (SPSS) and textured (TPSS), were colonized by S. epidermidis (SE) or S. aureus (SA) strains, all able to produce biofilms. After 15 days, all the samples were removed from the contaminated culture broth and constituted 4 groups of 20 contaminated samples: SPSS/SE (group I), SPSS/SA (group II), TPSS/SE (group III), TPSS/SE (group IV). In another group-group SEM-, 16 colonized samples were used for documentation with scanning electron microscopy (SEM). The remaining 16 samples were used to test the limits of detection of the sterility test. All samples of groups I-IV and 8 samples of group SEM were « washed » with a smooth brush in a povidone-iodine bath and rinsed with saline solution. A subset of the washed samples was sent for SEM and the others were immersed in sterile broth and were incubated at 35 °C for 3 weeks (groups I-IV). Fifteen days after contamination, all the samples in groups I-IV were colonized. In the SEM group, SEM images attested to the presence of bacteria in biofilm attached to the shells. After cleaning, SEM did not reveal any bacteria and there was no visible alteration in the outer structure of the shell. Sterility tests performed after decontamination in groups I-IV remained negative for all the samples. Breast prostheses recently contaminated with Staphylococci, frequently involved in peri-prosthetic breast implant infection and capable of producing biofilms, can be efficiently decontaminated by the procedure used in this study. Our decontamination procedure did not alter the surface structure of the prostheses. This decontamination procedure could allow reinsertion of an infected implant when peri-prosthetic infection occurs early after breast augmentation or breast reconstruction and when a salvage procedure is indicated. This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Mikeli, Aikaterini; Walter, Michael H
2016-01-01
Ceramic veneer fracture is a frequent complication in implant-borne fixed restorations. The retrospective clinical study assesses the effect of bruxism on this complication. A sample of 507 implant-borne fixed units inserted between 1995 and 2011 in 144 patients were examined. Any detected veneer fractures were assigned to one of four groups according to extent and position. A hypothetical correlation between bruxism and ceramic veneer fractures was examined. Of 34 patients (23.6%) with at least one ceramic veneer fracture, 24 were bruxers (70%) and 10 were nonbruxers (30%) (P = .002). Bruxism may pose a risk for ceramic fractures.
Medical devices of the head, neck, and spine.
Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G
2004-01-01
There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004
Springer, Jessica Collins; Harrysson, Ola L A; Marcellin-Little, Denis J; Bernacki, Susan H
2014-10-01
Transdermal osseointegrated prostheses (TOPs) are emerging as an alternative to socket prostheses. Electron beam melting (EBM) is a promising additive manufacturing technology for manufacture of custom, freeform titanium alloy (Ti6Al4V) implants. Skin ongrowth for infection resistance and mechanical stability are critically important to the success of TOP, which can be influenced by material composition and surface characteristics. We assessed viability and proliferation of normal human epidermal keratinocytes (NHEK) and normal human dermal fibroblasts (NHDF) on several Ti6Al4V surfaces: solid polished commercial, solid polished EBM, solid unpolished EBM and porous unpolished EBM. Cell proliferation was evaluated at days 2 and 7 using alamarBlue(®) and cell viability was analyzed with a fluorescence-based live-dead assay after 1 week. NHDF and NHEK were viable and proliferated on all Ti6Al4V surfaces. NHDF proliferation was highest on commercial and EBM polished surfaces. NHEK was highest on commercial polished surfaces. All EBM Ti6Al4V discs exhibited an acceptable biocompatibility profile compared to solid Ti6Al4V discs from a commercial source for dermal and epidermal cells. EBM may be considered as an option for fabrication of custom transdermal implants. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Wireless technologies for closed-loop retinal prostheses.
Ng, David C; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios
2009-12-01
In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.
Wireless technologies for closed-loop retinal prostheses
NASA Astrophysics Data System (ADS)
Ng, David C.; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios
2009-12-01
In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.
De Santis, Roberto; Gloria, Antonio; Russo, Teresa; D'Amora, Ugo; Varriale, Angelo; Veltri, Mario; Balleri, Piero; Mollica, Francesco; Riccitiello, Francesco; Ambrosio, Luigi
2014-12-18
This study aimed at investigating the effects of titanium implants and different configurations of full-arch prostheses on the biomechanics of edentulous mandibles. Reverse engineered, composite, anisotropic, edentulous mandibles made of a poly(methylmethacrylate) core and a glass fibre reinforced outer shell were rapid prototyped and instrumented with strain gauges. Brånemark implants RP platforms in conjunction with titanium Procera one-piece or two-piece bridges were used to simulate oral rehabilitations. A lateral load through the gonion regions was used to test the biomechanical effects of the rehabilitations. In addition, strains due to misfit of the one-piece titanium bridge were compared to those produced by one-piece cast gold bridges. Milled titanium bridges had a better fit than cast gold bridges. The stress distribution in mandibular bone rehabilitated with a one-piece bridge was more perturbed than that observed with a two-piece bridge. In particular the former induced a stress concentration and stress shielding in the molar and symphysis regions, while for the latter design these stresses were strongly reduced. In conclusion, prosthetic frameworks changed the biomechanics of the mandible as a result of both their design and manufacturing technology. Copyright © 2014 Elsevier Ltd. All rights reserved.
Short Implants Versus Standard Implants: Midterm Outcomes of a Clinical Study.
Benlidayi, M Emre; Ucar, Yurdanur; Tatli, Ufuk; Ekren, Orhun; Evlice, Burcu; Kisa, Halil Ibrahim; Baksi, Uygar
2018-02-01
The aim of this study was to evaluate the midterm survival rate, marginal bone resorption (MBR), and stability of short implants and to compare the results with standard length implants. A total of 38 patients were included. In total, 147 implants (Nucleoss Implants, Izmir, Turkey) were placed (86 short implants and 61 standard implants). Cement-retained metal-ceramic prostheses were fabricated. MBR was evaluated on periapical radiographs taken at implant placement, at the time of crown insertion and annually thereafter. The stability of the implants was evaluated by resonance frequency analysis. The 3- and 5-year cumulative survival rates for standard implants was 98.4% and for short implants was 96.5% (P = 0.644). The MBR of the short implants was significantly lower than that of the standard implants after 1, 2, and 3 years of loading (P < 0.05). No significant differences were found between 2 groups after 6 and 12 months of loading in terms of implant stability (implant stability quotient values) (P > 0.05). Within the limits of this study, it is concluded that short implants achieved similar results as standard implants after 3 to 5 years of loading.
Gonzalez-Perez, L-M; Gonzalez-Perez-Somarriba, B; Centeno, G; Vallellano, C; Montes-Carmona, J-F
2016-11-01
Temporo-Mandibular Joint (TMJ) replacement has been used clinically for years. The objective of this study was to evaluate outcomes achieved in patients with two different categories of TMJ prostheses. All patients who had a TMJ replacement (TMJR) implanted during the study period from 2006 through 2012 were included in this 3-year prospective study. All procedures were performed using the Biomet Microfixation TMJ Replacement System, and all involved replacing both the skull base component (glenoid fossa) and the mandibular condyle. Fifty-seven patients (38 females and 19 males), involving 75 TMJs with severe disease requiring reconstruction (39 unilateral, 18 bilateral) were operated on consecutively, and 68 stock prostheses and 7 custom-made prostheses were implanted. The mean age at surgery was 52.6±11.5 years in the stock group and 51.8±11.7 years in the custom-made group. In the stock group, after three years of TMJR, results showed a reduction in pain intensity from 6.4±1.4 to 1.6±1.2 (p<0.001), and an improvement in jaw opening from 2.7±0.9 cm to 4.2±0.7 cm (p<0.001). In the custom-made group, after three years of TMJR, results showed a reduction in pain intensity from 6.0±1.6 to 2.2±0.4 (p<0.001), and an improvement in jaw opening from 1.5±0.5 cm to 4.3±0.6 cm (p<0.001). No statistically significant differences between two groups were detected. The results of this three-year prospective study support the surgical placement of TMJ prostheses (stock prosthetic, and custom-made systems), and show that the approach is efficacious and safe, reduces pain, and improves maximum mouth opening movement, with few complications. As such, TMJR represents a viable technique and a stable long-term solution for cranio-mandibular reconstruction in patients with irreversible end-stage TMJ disease. Comparing stock and custom-made groups, no statistically significant differences were detected with respect to pain intensity reduction and maximum mouth opening improvement.
A first experience with digital complete overdentures.
Bajunaid, Salwa Omar
2016-07-01
The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.
Ficklscherer, Andreas; Wegener, Bernd; Niethammer, Thomas; Pietschmann, Matthias F; Müller, Peter E; Jansson, Volkmar; Trouillier, Hans-Heinrich
2013-03-01
Recent literature has shown a persistently high rate of aseptic loosening of the tibial component in total ankle prostheses. We analyzed the interface between the tibial bone and tibial component with a thermoelastic stress analysis to demonstrate load transmission onto the distal tibia. In this regard, we used two established ankle prostheses, which were implanted in two human cadaveric and in two third-generation composite tibia bones (Sawbones®, Sweden). Subsequently, the bones were attached to a hydropulser and a sinusoidal load of 700 N was applied. Both prostheses had an inhomogeneous load transmission onto the distal tibia. Instead of distributing load equally to the subarticular bone, forces were focused around the bolting stem, accumulating as stress maxima with forces up to 90 MPa. Furthermore, we were able to demonstrate load transmission into the metaphysis of the bone. As demonstrated in this study, anchoring systems with stems used in all established total ankle prostheses lead to an inhomogeneous load transmission onto the distal tibia, and furthermore, to a distribution of load into the weaker metaphyseal bone. For these reasons, we favor a prosthetic design with minimal bone resection and without any stem or stem-like anchoring system, which facilitates a homogeneous load transmission onto the distal tibia. Thermoelastic stress analysis proved to be a fast and easy-to-perform method to visualize load transmission.
Implant prostheses for convertibility, stress control, esthetics, and hygiene.
Garfield, R E
1988-07-01
A method of connecting "fixed partial denture" prostheses to osseointegrated implant fixtures has been described. The advantages of this system of restoration for partially and fully edentulous mouths are that it is more effective in addressing the problems of (1) stress-control on abutments, (2) a back-up system for abutment failures, (3) esthetics, and (4) control of bacterial plaques around abutments. To accomplish this procedure, the application of convertible periodontal prosthesis techniques with modifications to some existing implant systems is undertaken. The disadvantages of this method seem insignificant when one considers the complexities and risks involved with the present array of implant prosthesis alternatives. Some patients and dentists might consider the necessity of the prosthesis being detachable as one disadvantage. In reality, the prosthesis can be used as a fixed restoration until the patient has fully adapted to the new proprioception and appearance. A large percentage of patients feel uncomfortable with the word "removable" because it immediately creates a perception of unsightly metallic clasp display, palatal coverage, tongue interference, and negative body image. The use of the term "detachable" coupled with the doctor's offer to perform this task for the patient "whenever necessary" will usually relieve the patient's anxiety and allow the treatment to proceed. Once neuromuscular and esthetic adaptation have occurred and the patient has accepted the prosthesis, daily detaching and home-care hygiene by the patient will follow without incident. Esthetic improvement is obvious (Fig. 3).
Music Perception with Cochlear Implants: A Review
McDermott, Hugh J.
2004-01-01
The acceptance of cochlear implantation as an effective and safe treatment for deafness has increased steadily over the past quarter century. The earliest devices were the first implanted prostheses found to be successful in compensating partially for lost sensory function by direct electrical stimulation of nerves. Initially, the main intention was to provide limited auditory sensations to people with profound or total sensorineural hearing impairment in both ears. Although the first cochlear implants aimed to provide patients with little more than awareness of environmental sounds and some cues to assist visual speech-reading, the technology has advanced rapidly. Currently, most people with modern cochlear implant systems can understand speech using the device alone, at least in favorable listening conditions. In recent years, an increasing research effort has been directed towards implant users’ perception of nonspeech sounds, especially music. This paper reviews that research, discusses the published experimental results in terms of both psychophysical observations and device function, and concludes with some practical suggestions about how perception of music might be enhanced for implant recipients in the future. The most significant findings of past research are: (1) On average, implant users perceive rhythm about as well as listeners with normal hearing; (2) Even with technically sophisticated multiple-channel sound processors, recognition of melodies, especially without rhythmic or verbal cues, is poor, with performance at little better than chance levels for many implant users; (3) Perception of timbre, which is usually evaluated by experimental procedures that require subjects to identify musical instrument sounds, is generally unsatisfactory; (4) Implant users tend to rate the quality of musical sounds as less pleasant than listeners with normal hearing; (5) Auditory training programs that have been devised specifically to provide implant users with structured musical listening experience may improve the subjective acceptability of music that is heard through a prosthesis; (6) Pitch perception might be improved by designing innovative sound processors that use both temporal and spatial patterns of electric stimulation more effectively and precisely to overcome the inherent limitations of signal coding in existing implant systems; (7) For the growing population of implant recipients who have usable acoustic hearing, at least for low-frequency sounds, perception of music is likely to be much better with combined acoustic and electric stimulation than is typical for deaf people who rely solely on the hearing provided by their prostheses. PMID:15497033
Music perception with cochlear implants: a review.
McDermott, Hugh J
2004-01-01
The acceptance of cochlear implantation as an effective and safe treatment for deafness has increased steadily over the past quarter century. The earliest devices were the first implanted prostheses found to be successful in compensating partially for lost sensory function by direct electrical stimulation of nerves. Initially, the main intention was to provide limited auditory sensations to people with profound or total sensorineural hearing impairment in both ears. Although the first cochlear implants aimed to provide patients with little more than awareness of environmental sounds and some cues to assist visual speech-reading, the technology has advanced rapidly. Currently, most people with modern cochlear implant systems can understand speech using the device alone, at least in favorable listening conditions. In recent years, an increasing research effort has been directed towards implant users' perception of nonspeech sounds, especially music. This paper reviews that research, discusses the published experimental results in terms of both psychophysical observations and device function, and concludes with some practical suggestions about how perception of music might be enhanced for implant recipients in the future. The most significant findings of past research are: (1) On average, implant users perceive rhythm about as well as listeners with normal hearing; (2) Even with technically sophisticated multiple-channel sound processors, recognition of melodies, especially without rhythmic or verbal cues, is poor, with performance at little better than chance levels for many implant users; (3) Perception of timbre, which is usually evaluated by experimental procedures that require subjects to identify musical instrument sounds, is generally unsatisfactory; (4) Implant users tend to rate the quality of musical sounds as less pleasant than listeners with normal hearing; (5) Auditory training programs that have been devised specifically to provide implant users with structured musical listening experience may improve the subjective acceptability of music that is heard through a prosthesis; (6) Pitch perception might be improved by designing innovative sound processors that use both temporal and spatial patterns of electric stimulation more effectively and precisely to overcome the inherent limitations of signal coding in existing implant systems; (7) For the growing population of implant recipients who have usable acoustic hearing, at least for low-frequency sounds, perception of music is likely to be much better with combined acoustic and electric stimulation than is typical for deaf people who rely solely on the hearing provided by their prostheses.
The effect of bone growth onto massive prostheses collars in protecting the implant from fracture.
Fromme, Paul; Blunn, Gordon W; Aston, William J; Abdoola, Tasneem; Koris, Jacob; Coathup, Melanie J
2017-03-01
Limb-sparing distal femoral endoprotheses used in cancer patients have a high risk of aseptic loosening. It had been reported that young adolescent patients have a higher rate of loosening and fatigue fracture of intramedullary stems because the implant becomes undersized as patients grow. Extracortical bone growth into the grooved hydroxyapatite-coated collar had been shown to reduce failure rates. The stresses in the implant and femur have been calculated from Finite Element models for different stages of bone growth onto the collar. For a small diameter stem without any bone growth, a large stress concentration at the implant shoulder was found, leading to a significant fracture risk under normal walking loads. Bone growth and osseointergration onto the implant collar reduced the stress level in the implant to safe levels. For small bone bridges a risk of bone fracture was observed. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Merli, Mauro; Moscatelli, Marco; Mariotti, Giorgia; Rotundo, Roberto; Nieri, Michele
2013-01-01
To compare 100% deproteinised bovine bone matrix (DBBM) grafts (test group) with 100% autogenous bone (AB) grafts (control group) for lateral maxillary sinus floor elevation in a parallel group, superiority, randomised controlled trial. Patients with 1 to 3 mm of residual bone height below the maxillary sinus were randomised for sinus floor elevation with DBBM and AB grafts and simultaneous implant placement. Randomisation was computer generated with allocation concealment by sealed envelopes and the radiographic examiner was blinded to group assignment. The abutment connection was performed 8 months after surgery and insertion of the provisional prostheses was performed 9 months after surgery. Outcome variables were implant failures, prosthetic failures, complications, chair time, postoperative pain and radiographic bone level 6 months after loading. Forty patients were randomised: 20 (32 implants) to the DBBM group and 20 (27 implants) to the AB group. One patient from the AB group dropped out. Two implant failures occurred in the DBBM group and no implant failure occurred in the AB group (P = 0.4872). All of the planned prostheses could be delivered. One complication occurred in the DBBM group and 2 in the AB group (P = 0.6050). Chair time was shorter for the DBBM group, with a difference of 27.3 minutes (P = 0.0428). Pain difference measured with a visual analogue scale for 6 days post-surgery was 0.2 in favour of the DBBM group (P = 0.6838). The difference in vertical bone height was 0.0 mm (95% CI -1.1, 1.1; P = 0.9703) and the difference in marginal bone level was 0.3 in favour of AB (95% CI -0.3, 0.9; P = 0.3220). No differences apart from chair time were observed when comparing DBBM and AB grafts with simultaneous implant placement in sinus elevation.
Laurito, Domenica; Lamazza, Luca; Spink, Michael J.; De Biase, Alberto
2012-01-01
Summary Aims The success of maxillary and mandibular tissue supported implant prostheses varies in the literature, and the ideal protocol may be elusive from given the numerous studies. The oral rehabilitation option is an alternative to conventional dentures and should improve function, satisfaction, and retention. The purpose of this review article is to clarify these questions. Methods The search of literature reviews English non-anecdotal implant overdentures articles from 1991 to 2011. Results The results display an aggregate comprehensive list of categorical variables from the literature review. Overall success of maxillary and mandibular implant overdenture was respectively, 86.6% and 95.8%. Conclusion The literature indicates that the implant overdenture prosthesis provides predictable results – enhanced stability, function and a high-degree of satisfaction compared to conventional removable dentures. PMID:22783448
Does Bruxism Contribute to Dental Implant Failure? A Systematic Review and Meta-Analysis.
Zhou, Yi; Gao, Jinxia; Luo, Le; Wang, Yining
2016-04-01
Bruxism was usually considered as a contraindication for oral implanting. The causal relationship between bruxism and dental implant failure was remained controversial in existing literatures. This meta-analysis was performed to investigate the relationship between them. This review conducted an electronic systematic literature search in MEDLINE (PubMed) and EmBase in November 2013 without time and language restrictions. Meanwhile, a hand searching for all the relevant references of included studies was also conducted. Study information extraction and methodological quality assessments were accomplished by two reviewers independently. A discussion ensued if any disagreement occurred, and unresolved issues were solved by consulting a third reviewer. Methodological quality was assessed by using the Newcastle-Ottawa Scale tool. Odds ratio (OR) with 95% confidence interval (CI) was pooled to estimate the relative effect of bruxism on dental implant failures. Fixed effects model was used initially; if the heterogeneity was high, random effects model was chosen for meta-analysis. Statistical analyses were carried out by using Review Manager 5.1. In this meta-analysis review, extracted data were classified into two groups based on different units. Units were based on the number of prostheses (group A) and the number of patients (group B). In group A, the total pooled OR of bruxers versus nonbruxers for all subgroups was 4.72 (95% CI: 2.66-8.36, p = .07). In group B, the total pooled OR of bruxers versus nonbruxers for all subgroups was 3.83 (95% CI: 2.12-6.94, p = .22). This meta-analysis was performed to evaluate the relationship between bruxism and dental implant failure. In contrast to nonbruxers, prostheses in bruxers had a higher failure rate. It suggests that bruxism is a contributing factor of causing the occurrence of dental implant technical/biological complications and plays a role in dental implant failure. © 2015 Wiley Periodicals, Inc.
Rosenberg, Nahum; Neumann, Lars; Modi, Amit; Mersich, Istvan J; Wallace, Angus W
2007-01-01
Background The uncemented Nottingham Total Shoulder Replacement prosthesis system (Nottingham TSR) was developed from the previous BioModular® shoulder prosthesis taking into consideration the causes of the initial implant's failure. We investigated the impact of changes in the design of Nottingham TSR prosthesis on its survivorship rate. Methods Survivorship analyses of three types of uncemented total shoulder arthroplasty prostheses (BioModular®, initial Nottingham TSR and current Nottingham TSR systems with 11, 8 and 4 year survivorship data respectively) were compared. All these prostheses were implanted for the treatment of disabling pain in the shoulder due to primary and secondary osteoarthritis or rheumatoid arthritis. Each type of the prosthesis studied was implanted in consecutive group of patients – 90 patients with BioModular® system, 103 with the initial Nottingham TSR and 34 patients with the current Nottingham TSR system. The comparison of the annual cumulative survivorship values in the compatible time range between the three groups was done according to the paired t test. Results The 8-year and 11-year survivorship rates for the initially used modified BioModular® uncemented prosthesis were relatively low (75.6% and 71.7% respectively) comparing to the reported survivorship of the conventional cemented implants. The 8-year survivorship for the uncemented Nottingham TSR prosthesis was significantly higher (81.8%), but still not in the desired range of above 90%, that is found in other cemented designs. Glenoid component loosening was the main factor of prosthesis failure in both prostheses and mainly occurred in the first 4 postoperative years. The 4-year survivorship of the currently re-designed Nottingham TSR prosthesis, with hydroxylapatite coating of the glenoid baseplate, was significantly higher, 93.1% as compared to 85.1% of the previous Nottingham TSR. Conclusion The initial Nottingham shoulder prosthesis showed significantly higher survivorship than the BioModular® uncemented prosthesis, but lower than expected. Subsequently re-designed Nottingham TSR system presented a high short term survivorship rate that encourages its ongoing use PMID:17683577
Anchieta, Rodolfo B; Machado, Lucas S; Hirata, Ronaldo; Coelho, Paulo G; Bonfante, Estevam A
2016-10-01
This study evaluated the probability of survival (reliability) of platform-switched fixed dental prostheses (FDPs) cemented on different implant-abutment connection designs. Eighty-four-three-unit FDPs (molar pontic) were cemented on abutments connected to two implants of external or internal hexagon connection. Four groups (n = 21 each) were established: external hexagon connection and regular platform (ERC); external hexagon connection and switched platform (ESC); internal hexagon and regular platform (IRC); and internal hexagon and switched platform (ISC). Prostheses were subjected to step-stress accelerated life testing in water. Weibull curves and probability of survival for a mission of 100,000 cycles at 400 N (two-sided 90% CI) were calculated. The beta values of 0.22, 0.48, 0.50, and 1.25 for groups ERC, ESC, IRC, and ISC, respectively, indicated a limited role of fatigue in damage accumulation, except for group ISC. Survival decreased for both platform-switched groups (ESC: 74%, and ISC: 59%) compared with the regular matching platform counterparts (ERC: 95%, and IRC: 98%). Characteristic strength was higher only for ERC compared with ESC, but not different between internal connections. Failures chiefly involved the abutment screw. Platform switching decreased the probability of survival of FDPs on both external and internal connections. The absence in loss of characteristic strength observed in internal hexagon connections favor their use compared with platform-switched external hexagon connections. © 2016 Eur J Oral Sci.
Leaflet escape in a new bileaflet mechanical valve: TRI technologies.
Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino
2003-05-13
Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.
Papaspyridakos, Panos; Hirayama, Hiroshi; Chen, Chun-Jung; Ho, Chung-Han; Chronopoulos, Vasilios; Weber, Hans-Peter
2016-09-01
The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs). An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant- and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used. Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05). For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Vision rehabilitation in the case of blindness.
Veraart, Claude; Duret, Florence; Brelén, Marten; Oozeer, Medhy; Delbeke, Jean
2004-09-01
This article examines the various vision rehabilitation procedures that are available for early and late blindness. Depending on the pathology involved, several vision rehabilitation procedures exist, or are in development. Visual aids are available for low vision individuals, as are sensory aids for blind persons. Most noninvasive sensory substitution prostheses as well as implanted visual prostheses in development are reviewed. Issues dealing with vision rehabilitation are also discussed, such as problems of biocompatibility, electrical safety, psychosocial aspects, and ethics. Basic studies devoted to vision rehabilitation such as simulation in mathematical models and simulation of artificial vision are also presented. Finally, the importance of accurate rehabilitation assessment is addressed, and tentative market figures are given.
Design and validation of a real-time spiking-neural-network decoder for brain-machine interfaces.
Dethier, Julie; Nuyujukian, Paul; Ryu, Stephen I; Shenoy, Krishna V; Boahen, Kwabena
2013-06-01
Cortically-controlled motor prostheses aim to restore functions lost to neurological disease and injury. Several proof of concept demonstrations have shown encouraging results, but barriers to clinical translation still remain. In particular, intracortical prostheses must satisfy stringent power dissipation constraints so as not to damage cortex. One possible solution is to use ultra-low power neuromorphic chips to decode neural signals for these intracortical implants. The first step is to explore in simulation the feasibility of translating decoding algorithms for brain-machine interface (BMI) applications into spiking neural networks (SNNs). Here we demonstrate the validity of the approach by implementing an existing Kalman-filter-based decoder in a simulated SNN using the Neural Engineering Framework (NEF), a general method for mapping control algorithms onto SNNs. To measure this system's robustness and generalization, we tested it online in closed-loop BMI experiments with two rhesus monkeys. Across both monkeys, a Kalman filter implemented using a 2000-neuron SNN has comparable performance to that of a Kalman filter implemented using standard floating point techniques. These results demonstrate the tractability of SNN implementations of statistical signal processing algorithms on different monkeys and for several tasks, suggesting that a SNN decoder, implemented on a neuromorphic chip, may be a feasible computational platform for low-power fully-implanted prostheses. The validation of this closed-loop decoder system and the demonstration of its robustness and generalization hold promise for SNN implementations on an ultra-low power neuromorphic chip using the NEF.
The Influence Of Component Alignment On The Life Of Total Knee Prostheses
NASA Astrophysics Data System (ADS)
Bugariu, Delia; Bereteu, Liviu
2012-12-01
An arthritic knee affects the patient's life by causing pain and limiting movement. If the cartilage and the bone surfaces are severely affected, the natural joint is replaced with an artificial joint. The procedure is called total knee arthroplasty (TKA). Lately, the numbers of implanted total knee prostheses grow steadily. An important factor in TKA is the perfect alignment of the total knee prosthesis (TKP) components. Component misalignment can lead to the prosthesis loss by producing wear particles. The paper proposes a study on mechanical behaviors of a TKP based on numerical analysis, using ANSYS software. The numerical analysis is based on both the normal and the changed angle of the components alignment.
Iqbal, Taimoor; Shi, Lei; Wang, Ling; Liu, Yaxiong; Li, Dichen; Qin, Mian; Jin, Zhongmin
2017-06-01
The aim of this study was to design a hemi-pelvic prosthesis for a patient affected by pelvic sarcoma. To investigate the biomechanical functionality of the pelvis reconstructed with designed custom-made prosthesis, a patient-specific finite element model of whole pelvis with primary ligaments inclusive was constructed based on the computed tomography images of the patient. Then, a finite element analysis was performed to calculate and compare the stress distribution between the normal and implanted pelvis models when undergoing three different static conditions-both-leg standing, single-leg standing for the healthy and the affected one. No significant differences were observed in the stresses between the normal and reconstructed pelvis for both-leg standing, but 20%-40% larger stresses were predicted for the peak stress of the single-leg standing (affected side). Moreover, two- to threefold of peak stresses were predicted within the prostheses compared to that of the normal pelvis especially for single-leg standing case, however, still below the allowable fatigue limitation. The study on the load transmission functionality of prosthesis indicated that it is crucial to carry out finite element analysis for functional evaluation of the designed customized prostheses before three-dimensional printing manufacturing, allowing better understanding of the possible peak stresses within the bone as well as the implants for safety precaution. The finite element model can be equally applicable to other bone tumor model for biomechanical studying.
On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.
Falk, H
1990-01-01
The main aims of this thesis were (1) to study the functional characteristics of dentitions with mandibular implant-supported fixed cantilever prostheses - IFCP s- occluding with complete dentures, (2) to study in detail the magnitudes and distributions of axially directed closing and chewing forces in such dentitions, (3) to study the influence of number and distribution of occlusal contacts on the magnitude and distribution of closing and chewing forces, (4) to assess the vertical bending moment and the resulting vertical bending stress in the cantilever joints and (5) to find out whether the force distribution over the cantilever beams and the resulting vertical bending stress in the cantilever joint are influenced by the type of prosthetic construction in the opposing jaw. Closing and chewing forces were registered in altogether seventeen subjects by means of miniature strain gauge transducers mounted bilaterally and symmetrically in performed matrices in prosthetic appliances. Four, six or eight transducers, evenly distributed over the tooth-arch, permitted registrations of axially directed occlusal forces in several occluding areas simultaneously. In Papers I-IV, the implant-supported prostheses were installed in the mandible and occluded with complete dentures. In Paper V, group A, the fixture-supported prostheses were installed in the maxilla and occluded with tooth-supported fixed partial dentures whereas in group B, the arrangements were analogous to those in Papers I-IV. All subjects exhibited a rhythmic chewing pattern and preferred one side for chewing although both sides were used. Most chewing sequences were terminated with swallowing with occlusal force development. The mean total forces acting over the tooth-arch varied somewhat between groups and occlusal arrangements but averaged 350 and 170 N for closing and chewing respectively. Closing and chewing forces increased distally along the cantilever beams when occluding with complete dentures and decreased distally when occluding with fixed partial dentures. The distally increasing force distribution pattern could be altered to a distally decreasing force distribution pattern by infraoccluding the second cantilever unit by as little as 100 microns. Calculated vertical bending moments and stresses in the cantilever joints of the preferred chewing sides created by closing and chewing forces were larger in dentitions where the IFCP occluded with a complete denture than in dentitions where the IFCP occluded with a tooth-supported fixed partial denture.
Yilmaz, Burak; Seidt, Jeremy D; Clelland, Nancy L
2014-01-01
Variable abutment displacement could potentially affect proximal contacts, incisal edge position, or occlusion of implant-supported prostheses. This study aimed to measure and compare displacements of splinted and nonsplinted restorations into implants featuring internal conical connections as screws were tightened by hand or by torque driver. A stereolithic resin model was printed using computed tomography data from a patient missing mandibular left first and second molars. Two 5.0 × 11-mm implants were placed in the edentulous site using a surgical guide. Two sets (splinted and nonsplinted) of gold screw-retained prostheses were made indirectly to fit the implants in the stereolithic model representing the patient. The axial position of the crowns relative to a fixed location on the model was recorded following hand tightening using the three-dimensional image correlation technique and image correlation software. A pair of high-resolution digital cameras provided a synchronized view of the model during the experiment. Relative crown positions were again recorded after tightening with a torque driver to 25 Ncm. Testing was repeated randomly three times for each set of crowns. Displacement data after torque tightening were compared using a factorial analysis of variance with JMP 9.0 software (SAS) followed by a Tukey-Kramer post hoc test (α = .05). Interproximal contacts were evaluated using an 8-μm tin foil shim after tightening by hand and torque driver. Displacements for splinted and nonsplinted restorations differed only in a buccal direction. The nonsplinted crowns displaced significantly more than splinted crowns. Discernible differences were observed for the tin foil shim when dragged through proximal contacts following hand versus torque tightening. Differences between screw tightening by hand or torque driver should be taken into consideration during laboratory and clinical adjustments to prevent esthetic and functional complications.
Reft, Chester; Alecu, Rodica; Das, Indra J; Gerbi, Bruce J; Keall, Paul; Lief, Eugene; Mijnheer, Ben J; Papanikolaou, Nikos; Sibata, Claudio; Van Dyk, Jake
2003-06-01
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for radiation oncology patients with high-Z hip prostheses.
Yoon, Hyung-In; Han, Jung-Suk
2016-02-01
The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Laser vibrometer measurements and middle ear prostheses
NASA Astrophysics Data System (ADS)
Flock, Stephen T.; Dornhoffer, John; Ferguson, Scott
1997-05-01
One of us has developed an improved partial ossicular replacement prosthesis that is easier to implant and, based on pilot clinical measurements, results in better high-frequency hearing as compared to patients receiving one of the alternative prostheses. It is hypothesized that the primary reason for this is because of the relatively light weight (about 25 mg) and low compliance of the prosthesis, which could conceivably result in better high frequency vibrational characteristics. The purpose of our initial work was to develop an instrument suitable for objectively testing the vibrational characteristics of prostheses. We have developed a laser based device suitable for measuring the vibrational characteristics of the oval window or other structures of the middle ear. We have tested this device using a piezoelectric transducer excited at audio frequencies, as well as on the oval window in human temporal bones harvested from cadavers. The results illustrate that it is possible to non-invasively monitor the vibrational characteristics of anatomic structures with a very inexpensive photonic device.
Survival of various implant-supported prosthesis designs following 36 months of clinical function.
Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S
2000-12-01
The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.
Ricci, R.; Pecorella, I.; Ciardi, A.; Della Rocca, C.; Di Tondo, U.; Marchi, V.
1992-01-01
The histological features are reported of osteo-odonto-acrylic laminae removed from three patients who for differing underlying causes received Strampelli's osteo-odonto-keratoprostheses (OOK) 20, 16, and 12 years previously. It appears that preservation of the alveolar-dental ligament plays a definitive role in the maintenance of the prosthesis. If this tissue undergoes necrosis as a consequence of an inflammatory disease the implanted material is eventually lost. However when no such event occurs the OOK is well preserved and well tolerated even 20 years after implantation. Images PMID:1390492
The Development of Skull Prosthesis Through Active Contour Model.
Chen, Yi-Wen; Shih, Cheng-Ting; Cheng, Chen-Yang; Lin, Yu-Cheng
2017-09-09
Skull defects result in brain infection and inadequate brain protection and pose a general danger to patient health. To avoid these situations and prevent re-injury, a prosthesis must be constructed and grafted onto the deficient region. With the development of rapid customization through additive manufacturing and 3D printing technology, skull prostheses can be fabricated accurately and efficiently prior to cranioplasty. However, an unfitted skull prosthesis made with a metal implant can cause repeated infection, potentially necessitating secondary surgery. This paper presents a method of creating suitably geometric graphics of skull defects to be applied in skull repair through active contour models. These models can be adjusted in each computed tomography slice according to the graphic features, and the curves representing the skull defect can be modeled. The generated graphics can adequately mimic the natural curvature of the complete skull. This method will enable clinical surgeons to rapidly implant customized prostheses, which is of particular importance in emergency surgery. The findings of this research can help surgeons provide patients with skull defects with treatment of the highest quality.
Contemporary Patient Satisfaction Rates for Three-Piece Inflatable Penile Prostheses
Bernal, Raymond M.; Henry, Gerard D.
2012-01-01
Among the many treatments for erectile dysfunction, implantation of a penile prosthesis has been associated with high patient satisfaction rates. Specifically, the placement of a three-piece inflatable penile prosthesis (IPP) confers the highest rates of satisfaction. We reviewed the literature over the past 20 years regarding satisfaction rates for penile prostheses, with a focus on patients who had undergone an initial IPP implantation for erectile dysfunction. In all, 194 articles were reviewed, and of these, nine met inclusion criteria for analysis and data collation. We determined contemporary satisfaction rates to reflect patients' experiences with newer products and surgical approaches. Of importance, we noted that varied metrics were used to determine patient satisfaction, and overall satisfaction could not be precisely determined. Nevertheless, we found that patients in general were quite satisfied with their three-piece IPPs and restoration of sexual function. We also identified reasons for patient dissatisfaction and reviewed the literature to find ways by which satisfaction could be improved. Given the various means by which patient satisfaction was determined, future efforts should include standardized and validated questionnaires. PMID:22899909
Xie, Yesi; Meng, Huanxin; Han, Jie; Pan, Shaoxia; Zhang, Li; Shi, Dong
2016-02-01
To compare the incidence of technical complications of implant-supported fixed dental prostheses in Chinese patients with a history of moderate or severe periodontitis and periodontally healthy patients(PHP) and analyze the effects of interproximal papillae patterns on food impaction and efficacy of plaque control. A total of 103 partially edentulous patients treated with implant-supported fixed dental prostheses between December 2009 and December 2012 for a minimum 1-year follow-up period were recruited from Department of Periodontology, Peking University, School and Hospital of Stomatology. Based on the initial periodontal examination, the participants were divided into three groups: 30 PHP, 36 moderate periodontally compromised patients(mPCP) and 37 severe periodontally compromised patients(sPCP). Implant survival/loss, technical complications, plaque index, papilla index, food impaction and degree of proximal contact tightness of each patient were assessed around the implants at follow-up. According to the implant papilla index, the implants were divided into two groups: the "filling" group with the mesial and distal aspects with papilla index=3 and the "no filling" group with at least one aspect with papilla index<3. Data on implant survival, technical complications were analyzed. Comparisons of the incidence of technical complications were performed between the patients with different periodontal conditions with chi-square or Fisher's exact test. The influences of the interproximal papillae loss on food impaction and efficacy of plaque control were estimated with chi-square and Mann-Whitney U tests. The total implant survival rate was 100%(162/162) for all three groups. Technical complications were as following: veneer fractures(1.9%, 3/162), abutment screw loosening(1.9%, 3/162), prosthetic screw loosening(3.1%, 5/162) and decementation(3.1%, 5/162) in all subjects. No implant/screw fracture was noted. The incidence of technical complications in sPCP, mPCP and PHP did not yield statistically significant differences(P>0.05). The proportion of the implant with the mesial and distal papilla index=3 in the sPCP was less than that in the PHP and mPCP. The interproximal papillae loss did not appear to affect the food impaction and the plaque index in all three groups(P>0.05). However, for the PHP, the accumulation of plaque at buccal aspect was more in the "no filling" group compared with the "filling" group (implant plaque index[M(Q)]: 1[1] vs 0[0]), and for the sPCP, the accumulation of plaque at lingual aspect was more in the "filling" group compared with the "no filling" group(implant plaque index[M(Q)]: 1[1] vs 0[1], (P<0.05). The patients with a history of severe periodontitis did not exhibit more technical problems compared with the periodontally healthy patients. The interproximal papillae loss did not show a negative impact on the plaque control and food impaction. However, for the sPCP, changing the morphology and the position of the interproximal contact point to reduce the interdental black triangle may lead to accumulation of plaque at lingual aspect. More attention should be placed on the morphology design of prosthesis, but not the papillae filling up the interproximal space.
Computer-aided design of the human aortic root.
Ovcharenko, E A; Klyshnikov, K U; Vlad, A R; Sizova, I N; Kokov, A N; Nushtaev, D V; Yuzhalin, A E; Zhuravleva, I U
2014-11-01
The development of computer-based 3D models of the aortic root is one of the most important problems in constructing the prostheses for transcatheter aortic valve implantation. In the current study, we analyzed data from 117 patients with and without aortic valve disease and computed tomography data from 20 patients without aortic valvular diseases in order to estimate the average values of the diameter of the aortic annulus and other aortic root parameters. Based on these data, we developed a 3D model of human aortic root with unique geometry. Furthermore, in this study we show that by applying different material properties to the aortic annulus zone in our model, we can significantly improve the quality of the results of finite element analysis. To summarize, here we present four 3D models of human aortic root with unique geometry based on computational analysis of ECHO and CT data. We suggest that our models can be utilized for the development of better prostheses for transcatheter aortic valve implantation. Copyright © 2014 Elsevier Ltd. All rights reserved.
AlBader, Bader; AlHelal, Abdulaziz; Proussaefs, Periklis; Garbacea, Antonela; Kattadiyil, Mathew T; Lozada, Jaime
Implant-supported fixed complete dentures, often referred to as hybrid prostheses, have been associated with high implant survival rates but also with a high incidence of mechanical prosthetic complications. The most frequent of these complications have been fracture and wear of the veneering material. The proposed design concept incorporates the occlusal surfaces of the posterior teeth as part of a digital milled metal framework by designing the posterior first molars in full contour as part of the framework. The framework can be designed, scanned, and milled from a titanium blank using a milling machine. Acrylic resin teeth can then be placed on the framework by conventional protocol. The metal occlusal surfaces of the titanium-countered molars will be at centric occlusion. It is hypothesized that metal occlusal surfaces in the posterior region may reduce occlusal wear in these types of prostheses. When the proposed design protocol is followed, the connection between the metal frame and the cantilever part of the prosthesis is reinforced, which may lead to fewer fractures of the metal framework.
Deb, A.; Jay Mathias, Suresh; Fraser Saxby, Mark; Fernando, Herman
2015-01-01
Testicular prostheses are regularly used in urological surgery and are important for postoperative psychological well-being in many patients undergoing orchiectomy. One of the recognised complications of this procedure is graft extrusion, which can result in significant morbidity for patients and require operative reintervention. Whilst most cases of extrusion involve upward graft migration to the external inguinal ring or direct displacement through the scrotal skin, we present an unusual case of complete expulsion of testicular implant three weeks postoperatively through a previously healthy scrotum. During surgical insertion of testicular prostheses, the urological surgeon must carefully consider the different surgical strategies at each step of the operation to prevent future extrusion of the graft. A stepwise review of the preventive surgical strategies to reduce the risk of graft extrusion encompasses the choice of optimal surgical incision, the technique of dissection to create the receiving anatomical pouch, the method of fixation of the implant within the receiving hemiscrotum, and the adoption of good postoperative care measures in line with the principles of sound scrotal surgery. PMID:26137344
Rehabilitation with implant-supported overdentures in total edentulous patients: A review.
Martínez-Lage-Azorín, Juan F; Segura-Andrés, Gustavo; Faus-López, Joan; Agustín-Panadero, Rubén
2013-12-01
The main aim of this review article is to discuss implant-supported overdentures (ISOs) as treatment in edentulous patients. Besides, we will try to discuss among the different treatment options in such patients and to analyze their validity when ISOs are compared with other clinical modalities. At the same time, we will try to suggest clinical guidelines supported by current clinical studies. We performed a Medline search and review of pertinent articles on the mentioned subject from 1986 to 2011. As a searching strategy, we used the following words: implant-supported overdentures, attachment systems, Locator attachment, cantilever, fixed prosthesis. Implant-supported overdentures constitute an accurate and predictable treatment option and achieve a higher patients' satisfaction. This type of treatment constitutes a cheaper treatment than fixed prostheses and in some patients, with loss of lip support or with an interoclusal space larger than 15 mm, the choice of implant-supported overdentures seems to prevent future aesthetic or phonetic problems. Key words:Overdentures, implant occlusion, implant rehabilitation, total edentulous rehabilitation, fixed prosthesis.
Aparicio, C
1994-10-01
To maintain osseointegration, it is essential that the prosthesis fit with total passivity because the absence of a periodontal ligament makes the implant unable to adapt its position to a nonpassive framework. The traditional system of building a metal framework by melting over mechanized pieces--called gold cylinders in the Brånemark system--has been modified so these pieces are joined to the metal framework by means of physicochemical bonding. This bond is achieved by treating the metallic surfaces with a Silicoater system and a composite resin cement that sets in the mouth using an improved cementing protocol. In this paper, the clinical viability of this new philosophy, shown over 2 years, is presented. A total of 64 prostheses (39 maxillary and 25 mandibular) supported by 214 abutments, with an average observation period of 9 months, were evaluated. The results show that it is possible to routinely obtain a ceramometal prosthesis with a totally passive circular fitting while maintaining the possibility of retrieval, thus making postceramic soldering unnecessary.
Clark, R K; Comfort, M B
1994-01-01
Dental restoration of the edentulous mandible opposing natural maxillary teeth is often associated with a number of problems, particularly in the occlusion, and an accelerated rate of alveolar bone resorption in the edentulous mandible resulting from occlusal loading. The advent of osseointegrated implants would seem to provide a new means of treating these cases. Accordingly, the cases of six patients for whom either fixed partial dentures or over-dentures supported by Brånemark implants were provided, are reviewed. Three of the mandibles were normal and three had bone grafts. Results so far indicate that this is a viable alternative for treating such cases.
Treatment of Orally Handicapped Edentulous Older Adults Using Dental Implants.
Zahedi, Charles
2016-07-01
The oral handicap of complete edentulism is the terminal outcome of a multifactorial process involving biological factors and patient-related factors. Fully edentulous orally handicapped older adults have been neglected because removable acrylic dentures have been the classic therapy for complete edentulism but are only rehabilitative, not therapeutic. Not replacing missing teeth with stable dentures could prevent adequate food intake. Osseointegrated endosseous implants used as a therapeutic adjunct can reduce the problem of long-term bone resorption to less than 0.1 mm per year. Implant-borne prostheses substantially increase the overall health and quality of life of orally handicapped fully edentulous older adults. Copyright © 2016 Elsevier Inc. All rights reserved.
Kanazawa, Manabu; Tanoue, Mariko; Miyayasu, Anna; Takeshita, Shin; Sato, Daisuke; Asami, Mari; Lam, Thuy Vo; Thu, Khaing Myat; Oda, Ken; Komagamine, Yuriko; Minakuchi, Shunsuke; Feine, Jocelyne
2018-05-01
Mandibular overdentures retained by a single implant placed in the midline of edentulous mandible have been reported to be more comfortable and function better than complete dentures. Although single-implant overdentures are still more costly than conventional complete dentures, there are a few studies which investigated whether mandibular single-implant overdentures are superior to complete dentures when patient general satisfaction is compared. The aim of this study is to assess patient general satisfaction with mandibular single-implant overdentures and complete dentures. This study is a randomized crossover trial to compare mandibular single-implant overdentures and complete dentures in edentulous individuals. Participant recruitment is ongoing at the time of this submission. Twenty-two participants will be recruited. New mandibular complete dentures will be fabricated. A single implant will be placed in the midline of the edentulous mandible. The mucosal surface of the complete denture around the implant will be relieved for 3 months. The participants will then be randomly allocated into 2 groups according to the order of the interventions; group 1 will receive single-implant overdentures first and will wear them for 2 months, followed by complete dentures for 2 months. Group 2 will receive the same treatments in a reverse order. After experiencing the 2 interventions, the participants will choose one of the mandibular prostheses, and yearly follow-up visits are planned for 5 years. The primary outcome of this trial is patient ratings of general satisfaction on 100 mm visual analog scales. Assessments of the prostheses and oral health-related quality of life will also be recorded as patient-reported outcomes. The secondary outcomes are cost and time for treatment. Masticatory efficiency and cognitive capacity will also be recorded. Furthermore, qualitative research will be performed to investigate the factors associated with success of these mandibular denture types. Clinical outcomes, such as implant survival rate, marginal bone loss, and prosthodontic complications, will also be recorded. The results of this randomized crossover trial will clarify whether mandibular single implants and overdentures for edentulous individuals provide better patient general satisfaction when compared to conventional complete dentures. This clinical trial was registered at the University Hospital Medical Information Network (UMIN) Center (UMIN000017883).
Gender differences of the morphology of the distal femur and proximal tibia in a Korean population.
Lim, Hong-Chul; Bae, Ji-Hoon; Yoon, Ji-Yeol; Kim, Seung-Ju; Kim, Jae-Gyoon; Lee, Jae-Moon
2013-01-01
We conducted this study to determine whether the sizes of distal femurs and proximal tibiae in Korean men and women are different, and to assess suitability of the sizes of prostheses currently used in Korea. We performed morphological analysis of proximal tibia and distal femur on 115 patients (56 male, 59 female) using MRI to investigate a gender difference. Tibial mediolateral dimension (tMAP), tibial medial anteroposterior dimension (tMAP), tibial lateral anteroposterior dimension (tLAP) femoral mediolateral dimension (fML), femoral medial anteroposterior dimension (fMAP), and femoral lateral anteroposterior dimension (fLAP) were measured. The ratio of tMAP and tLAP to tML (plateau aspect ratio, tAP/tML×100%), and that of fMAP and fLAP to fML (condylar aspect ratio, fAP/fML×100%) were calculated. The measurements were compared with the similar dimensions of four total knee implants currently used. The tML and tAP lengths showed a significant gender difference (P<0.05). The plateau aspect ratio (tMAP/tML) revealed a significant difference between male (0.74±0.05) and female (0.68±0.04, P<0.05). For morphotype of distal femur, males were found to have significantly large values (P<0.05) in the parameters, except for fLAP. With regards to the ratio of the ML width to the AP length, the women showed a narrower ML width than the men. Both genders were distributed within the range of the dimensions of the prostheses currently used prostheses. Korean population revealed that women have smaller dimensions than male counterparts. In both genders, a relatively small size of prostheses matches distal femur and proximal tibia better among the implants currently used in Korea. Copyright © 2012 Elsevier B.V. All rights reserved.
Long-term follow-up of stentless prosthesis.
Sansone, Fabrizio; Dato, Guglielmo Mario Actis; Zingarelli, Edoardo; Ferrero, Emanuele; Prot, Sara; Ceresa, Fabrizio; Patanè, Francesco; Casabona, Riccardo
2014-05-01
Stentless prostheses have an interesting hemodynamic performance when compared to stented prostheses and are recommended in cases of small aortic annulus. From January 1996 to January 2004, 138 patients suffering from aortic disease, underwent aortic valve replacement. • Group A: 93 patients underwent stentless aortic valve implantation [stentless Biocor (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil) and stentless Sorin (Sorin Group, Saluggia, Italy)]. • Group B: 45 patients underwent stented aortic valve implantation (stented Biocor). Patients were assessed by clinical evaluation and echocardiography after a mean follow up of 124.5 ± 58.2 months. There was a significant difference in terms of time of extracorporeal circulation and aortic cross clamp. The actuarial survival at 4, 8, 12, and 15 years is 77%, 50%, 21%, and 18%, respectively. Freedom from reoperation at 4, 8, 12, and 14 years was 92%, 83%, 73%, and 63%, respectively. Freedom from all events, death, and reoperation at 4, 8, 12, and 14 years was 70%, 39%, 13%, and 8%, respectively. There is no statistical difference among the two groups in terms of actuarial survival, freedom from reoperation, and freedom from re-hospitalization for prosthesis-related causes. There was a significantly higher incidence of pacemaker implantation in Group A and the causes are not known. The rate of freedom from reoperation is high in both groups for the patients who remained alive. There was no statistical difference about prosthesis dysfunction between the two groups. The higher incidence of death in Group A cannot be explained by causes related to the prosthesis because there is no difference in terms of causes of death. Rates of reoperation did not differ between the two groups. The results obtained with stentless prostheses are encouraging even in long-term follow-up. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Performance sustaining intracortical neural prostheses
NASA Astrophysics Data System (ADS)
Nuyujukian, Paul; Kao, Jonathan C.; Fan, Joline M.; Stavisky, Sergey D.; Ryu, Stephen I.; Shenoy, Krishna V.
2014-12-01
Objective. Neural prostheses, or brain-machine interfaces, aim to restore efficient communication and movement ability to those suffering from paralysis. A major challenge these systems face is robust performance, particularly with aging signal sources. The aim in this study was to develop a neural prosthesis that could sustain high performance in spite of signal instability while still minimizing retraining time. Approach. We trained two rhesus macaques implanted with intracortical microelectrode arrays 1-4 years prior to this study to acquire targets with a neurally-controlled cursor. We measured their performance via achieved bitrate (bits per second, bps). This task was repeated over contiguous days to evaluate the sustained performance across time. Main results. We found that in the monkey with a younger (i.e., two year old) implant and better signal quality, a fixed decoder could sustain performance for a month at a rate of 4 bps, the highest achieved communication rate reported to date. This fixed decoder was evaluated across 22 months and experienced a performance decline at a rate of 0.24 bps yr-1. In the monkey with the older (i.e., 3.5 year old) implant and poorer signal quality, a fixed decoder could not sustain performance for more than a few days. Nevertheless, performance in this monkey was maintained for two weeks without requiring additional online retraining time by utilizing prior days’ experimental data. Upon analysis of the changes in channel tuning, we found that this stability appeared partially attributable to the cancelling-out of neural tuning fluctuations when projected to two-dimensional cursor movements. Significance. The findings in this study (1) document the highest-performing communication neural prosthesis in monkeys, (2) confirm and extend prior reports of the stability of fixed decoders, and (3) demonstrate a protocol for system stability under conditions where fixed decoders would otherwise fail. These improvements to decoder stability are important for minimizing training time and should make neural prostheses more practical to use.
Long-term results of uncemented alumina acetabular implants.
Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V
1994-01-01
We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.
Lemke, B; Rathmann, J; Wiebe, V; Witzel, U
1991-08-01
Acute mechanical failure of prosthetic heart valves is rare, but associated with high mortality when occurring. For convexo-concave Björk-Shiley prostheses only fractures of the outlet strut are reported. We present a case of lethal mechanical complication 5 years after implantation. By additional metallurgic analysis we were able to identify a sequential course of the outlet strut fracture. This could lead to new approaches for early detection of this complication.
Reliability of retrievable cemented implant-supported prostheses.
Nissan, Joseph; Snir, David; Rosner, Ofir; Kolerman, Roni; Chaushu, Liat; Chaushu, Gavriel
2016-05-01
One of the disadvantages of a cemented implant restoration is the potential difficulty of retrieving it. The restoration may be destroyed during removal. The purpose of this retrospective clinical study was to assess the long-term survival rates of cemented posterior metal ceramic implant-supported prostheses (ISPs) with a metal screw access hole. During a 12-year period, 274 cemented ISPs with an abutment screw access hole in the metal framework were assessed and served as the study group, and 119 conventional cemented ISPs (without access hole) served as the control group. Participants were followed every 6 months in the first year and once a year subsequently. Ceramic fracture, screw loosening, and refabrication were the prosthetic outcome parameters evaluated at the recall. The Pearson Chi square and Fisher exact test were used to compare the outcome parameters between the control and study groups. A total of 1005 implants and 393 ISPs were evaluated. Ceramic fracture occurred in 6.6% of the ISPs (6.2% test and 7.6% control). Screw loosening occurred in 3.28% of the test group and 3.36% of the control group. Refabrication of ISPs was done in 2.79% of all restorations, (1.45% test and 6.72% control [P=.012]). Within the limits of this study, preparing cemented ISPs with a screw access hole in the metal framework improves ISP survival rates over time and lowers the cost of maintenance without increasing the risk for porcelain fracture or screw loosening. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Prosthetic knee design by simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollerbach, K; Hollister, A
1999-07-30
Although 150,000 total knee replacement surgeries are performed annually in North America, current designs of knee prostheses have mechanical problems that include a limited range of motion, abnormal gait patterns, patellofemoral joint dysfunction, implant loosening or subsidence, and excessive wear. These problems fall into three categories: failure to reproduce normal joint kinematics, which results in altered limb function; bone-implant interface failure; and material failure. Modern computer technology can be used to design, prototype, and test new total knee implants. The design team uses the full range of CAD-CAM to design and produce implant prototypes for mechanical and clinical testing. Closermore » approximation of natural knee kinematics and kinetics is essential for improved patient function and diminished implant loads. Current knee replacement designs are based on 19th Century theories that the knee moves about a variable axis of rotation. Recent research has shown, however, that knee motion occurs about two fixed, offset axes of rotation. These aces are not perpendicular to the long axes of the bones or to each other, and the axes do not intersect. Bearing surfaces of mechanisms that move about axes of rotation are surfaces of revolution of those axes which advanced CAD technology can produce. Solids with surfaces of revolution for the two axes of rotation for the knee have been made using an HP9000 workstation and Structural Ideas Master Series CAD software at ArthroMotion. The implant's CAD model should closely replicate movements of the normal knee. The knee model will have a range of flexion-extension (FE) from -5 to 120 degrees. Movements include varus, valgus, internal and external rotation, as well as flexion and extension. The patellofemoral joint is aligned perpendicular to the FE axis and replicates the natural joint more closely than those of existing prostheses. The bearing surfaces will be more congruent than current designs and should generate lower stresses in the materials.« less
Lewis, Philip M; Ackland, Helen M; Lowery, Arthur J; Rosenfeld, Jeffrey V
2015-01-21
The field of neurobionics offers hope to patients with sensory and motor impairment. Blindness is a common cause of major sensory loss, with an estimated 39 million people worldwide suffering from total blindness in 2010. Potential treatment options include bionic devices employing electrical stimulation of the visual pathways. Retinal stimulation can restore limited visual perception to patients with retinitis pigmentosa, however loss of retinal ganglion cells precludes this approach. The optic nerve, lateral geniculate nucleus and visual cortex provide alternative stimulation targets, with several research groups actively pursuing a cortically-based device capable of driving several hundred stimulating electrodes. While great progress has been made since the earliest works of Brindley and Dobelle in the 1960s and 1970s, significant clinical, surgical, psychophysical, neurophysiological, and engineering challenges remain to be overcome before a commercially-available cortical implant will be realized. Selection of candidate implant recipients will require assessment of their general, psychological and mental health, and likely responses to visual cortex stimulation. Implant functionality, longevity and safety may be enhanced by careful electrode insertion, optimization of electrical stimulation parameters and modification of immune responses to minimize or prevent the host response to the implanted electrodes. Psychophysical assessment will include mapping the positions of potentially several hundred phosphenes, which may require repetition if electrode performance deteriorates over time. Therefore, techniques for rapid psychophysical assessment are required, as are methods for objectively assessing the quality of life improvements obtained from the implant. These measures must take into account individual differences in image processing, phosphene distribution and rehabilitation programs that may be required to optimize implant functionality. In this review, we detail these and other challenges facing developers of cortical visual prostheses in addition to briefly outlining the epidemiology of blindness, and the history of cortical electrical stimulation in the context of visual prosthetics. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Malrotation of the McGhan Style 510 prosthesis.
Schots, Jeroen M P; Fechner, Maarten R; Hoogbergen, Maarten M; van Tits, Herm W H J
2010-07-01
Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors encountered a high number of prosthesis malrotations on self-reported follow-up. Therefore, a retrospective medical record review was performed to determine the prevalence of malrotation of the Style 510 prosthesis. From January of 2005 to December of 2006, 73 (146 prostheses) aesthetic augmentation mammaplasty procedures were performed using Style 510 prostheses. All prostheses were placed subglandularly through an inframammary incision. The postsurgical protocol for the first 3 weeks involved wearing a nonwired compression bra, abstinence from sports activities, and abstinence from heavy labor. Standard follow-up was at 1 week, 3 months, and if necessary. On self-reported follow-up, 8.2 percent of all prostheses were rotated. These rotations all occurred unilaterally after a mean period of 10 months (range, 3 to 19 months). No relation to an inciting incident or prosthesis volume could be found. The number of rotations of the Style 510 prosthesis seen after primary aesthetic breast augmentation is high. An obvious cause of this major problem has not been found. This led the authors to discontinue using the Style 510 prosthesis for primary aesthetic mammary augmentations in their practice.
Intracapsular implant rupture: MR findings of incomplete shell collapse.
Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C; Georgiade, G S; DeLong, D; Spritzer, C E
1997-01-01
The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses. MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings included (a) complete shell collapse (linguine sign), 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; (c) radial folds, 31 implants; and (d) normal, 1 implant. The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants. At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability. MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.
Effect of Framework in an Implant-Supported Full-Arch Fixed Prosthesis: 3D Finite Element Analysis.
Menini, Maria; Pesce, Paolo; Bevilacqua, Marco; Pera, Francesco; Tealdo, Tiziano; Barberis, Fabrizio; Pera, Paolo
2015-01-01
The aim of this study was to analyze through a three-dimensional finite element analysis (3D-FEA) stress distribution on four implants supporting a full-arch implant-supported fixed prosthesis (FFP) using different prosthesis designs. A 3D edentulous maxillary model was created and four implants were virtually placed into the maxilla and splinted, simulating an FFP without framework, with a cast metal framework, and with a carbon fiber framework. An occlusal load of 150 N was applied, stresses were transmitted into peri-implant bone, and prosthodontic components were recorded. 3D-FEA revealed higher stresses on the implants (up to +55.16%), on peri-implant bone (up to +56.93%), and in the prosthesis (up to +70.71%) when the full-acrylic prosthesis was simulated. The prosthesis with a carbon fiber framework showed an intermediate behavior between that of the other two configurations. This study suggests that the presence of a rigid framework in full-arch fixed prostheses provides a better load distribution that decreases the maximum values of stress at the levels of implants, prosthesis, and maxillary bone.
Akca, Kivanc; Eser, Atilim; Eckert, Steven; Cavusoglu, Yeliz; Cehreli, Murat Cavit
2013-01-01
To compare biomechanical outcomes of immediately and conventionally loaded bar-retained implant-supported maxillary overdentures using finite element stress analysis. Finite element models were created to replicate the spatial positioning of four 4.1 × 12-mm implants in the completely edentulous maxillae of four cadavers to support bar-retained overdentures with 7-mm distal extension cantilevers. To simulate the bone-implant interface of immediately loaded implants, a contact situation was defined at the interface; conventional loading was simulated by "bonding" the implants to the surrounding bone. The prostheses were loaded with 100 N in the projected molar regions bilaterally, and strain magnitudes were measured at the buccal aspect of bone. The amplitude of axial and lateral strains, the overall strain magnitudes, and the strain magnitudes around anterior and posterior implants in the immediate loading group were comparable to those seen in the conventional loading group, suggesting that the loading regimens created similar stress/strain fields (P > .05). Conventional and immediate loading of maxillary implants supporting bar-retained overdentures resulted in similar bone strains.
Two-piece impression procedure for implant-retained orbital prostheses.
Ozcelik, Tuncer Burak; Yilmaz, Burak
2012-01-01
Obtaining an accurate impression of facial tissues with undercuts and extraoral implants has always been a challenge for both clinicians and patients. This report describes a three-step, two-piece technique that enables an accurate and comfortable impression of undercut tissues and extraoral implants in an orbital defect. An impression of the basal tissue surface of the defect area was made using a medium-body polyether impression material followed by an impression of the entire face of the patient made with a polyvinyl siloxane (PVS) impression material. First, the PVS impression material was removed; second, the impression posts were removed from the magnets; and third, the polyether impression was removed from the defect. The impression posts were attached to the implant analogs and placed in the negative spaces in the polyether impression. The polyether impression, which carries the implant analogs and impression posts, was placed in the PVS impression through the negative spaces. This technique minimizes trauma to the soft tissues and implants during impression making and also does not require additional materials.
The effectiveness of 2-implant overdentures - a pragmatic international multicentre study.
Rashid, F; Awad, M A; Thomason, J M; Piovano, A; Spielberg, G P; Scilingo, E; Mojon, P; Müller, F; Spielberg, M; Heydecke, G; Stoker, G; Wismeijer, D; Allen, F; Feine, J S
2011-03-01
The purpose of this multicentre observational study was to determine patient satisfaction with either conventional dentures or mandibular 2-implant overdentures in a 'real world' setting. Two hundred and three edentulous patients (mean age 68·8 ± 10·4 years) were recruited at eight centres located in North America, South America and Europe. The patients were provided with new mandibular conventional dentures or implant overdentures supported by two implants and ball attachments. At baseline and at 6 months post-treatment, they rated their satisfaction with their mandibular prostheses on 100-mm visual analogue scale questionnaires. One hundred and two (50·2%) participants had valid baseline and 6-month satisfaction data. Although both groups reported improvements, the implant overdenture group reported significantly higher ratings of overall satisfaction, comfort, stability, ability to speak and ability to chew. These results suggest that edentulous patients who choose mandibular implant overdentures have significantly greater improvements in satisfaction, despite their relatively higher cost, than those who choose new conventional dentures. © 2010 Blackwell Publishing Ltd.
Fabrication of fixed implant prostheses using function bite impression technique (FBI technique).
Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro; Kurtz, Kenneth S
2012-10-01
The patient was partially edentulous, lacking both the first mandibular molars. The FBI and the conventional impression technique were used for the fabrication of implant-fixed prosthesis replacing the right and left molars, respectively. In the FBI technique, the definitive impression was made under occlusal force and functionally generated path (FGP) recording at the same time. The right and left occlusal contact areas were compared after completing the implant-fixed prosthesis rehabilitation. It has been suggested that accuracy of the impression and maxillomandibular registration is necessary to ensure a satisfactory long-term clinical outcome. The transfer of the exact position of the implants to the working cast is even more important because implants lack the mobility of natural teeth. There are displacement differences between implants and natural teeth under occlusal force. The FBI technique may compensate for this difference in accuracy. Using the FBI technique, a precise prosthesis could be produced by completing simultaneously the maxillomandibular registration, impression and FGP. Copyright © 2012 Japan Prosthodontic Society. All rights reserved.
Nie, Kaibao; Ling, Leo; Bierer, Steven M; Kaneko, Chris R S; Fuchs, Albert F; Oxford, Trey; Rubinstein, Jay T; Phillips, James O
2013-06-01
A vestibular neural prosthesis was designed on the basis of a cochlear implant for treatment of Meniere's disease and other vestibular disorders. Computer control software was developed to generate patterned pulse stimuli for exploring optimal parameters to activate the vestibular nerve. Two rhesus monkeys were implanted with the prototype vestibular prosthesis and they were behaviorally evaluated post implantation surgery. Horizontal and vertical eye movement responses to patterned electrical pulse stimulations were collected on both monkeys. Pulse amplitude modulated (PAM) and pulse rate modulated (PRM) trains were applied to the lateral canal of each implanted animal. Robust slow-phase nystagmus responses following the PAM or PRM modulation pattern were observed in both implanted monkeys in the direction consistent with the activation of the implanted canal. Both PAM and PRM pulse trains can elicit a significant amount of in-phase modulated eye velocity changes and they could potentially be used for efficiently coding head rotational signals in future vestibular neural prostheses.
Implant rehabilitation in bruxism patient
Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas
2014-01-01
A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215
Jacobs, R; van Steenberghe, D
1993-03-01
A sustained submaximal (50%) clenching effort was performed in four patient groups to establish whether implant-supported prosthetic reconstructions influence myoelectrical signal parameters. The first group consisted of patients with natural teeth in both jaws. The other three groups consisted of patients who were edentulous in both jaws: one group had complete dentures; one had an overdenture in the mandible on two implants connected by a bar; and the third had an implant-supported fixed prosthesis in either the maxilla or the mandible. Surface electromyography indicated an increased myoelectrical output level that paralleled a higher bite force level for implant-supported reconstructions compared with complete dentures. Power spectrum analysis revealed a downward shift of the mean power frequency during sustained clenching in all groups except the implant-supported fixed prosthesis. The absence of a spectral shift in the latter group probably reflected a fear of biting too hard and fracturing the prosthesis.
Gonzalez-Perez-Somarriba, Borja; Centeno, Gabriel; Vallellano, Carpóforo; Montes-Carmona, Jose-Francisco
2016-01-01
Background Temporo-Mandibular Joint (TMJ) replacement has been used clinically for years. The objective of this study was to evaluate outcomes achieved in patients with two different categories of TMJ prostheses. Material and Methods All patients who had a TMJ replacement (TMJR) implanted during the study period from 2006 through 2012 were included in this 3-year prospective study. All procedures were performed using the Biomet Microfixation TMJ Replacement System, and all involved replacing both the skull base component (glenoid fossa) and the mandibular condyle. Results Fifty-seven patients (38 females and 19 males), involving 75 TMJs with severe disease requiring reconstruction (39 unilateral, 18 bilateral) were operated on consecutively, and 68 stock prostheses and 7 custom-made prostheses were implanted. The mean age at surgery was 52.6±11.5 years in the stock group and 51.8±11.7 years in the custom-made group. In the stock group, after three years of TMJR, results showed a reduction in pain intensity from 6.4±1.4 to 1.6±1.2 (p<0.001), and an improvement in jaw opening from 2.7±0.9 cm to 4.2±0.7 cm (p<0.001). In the custom-made group, after three years of TMJR, results showed a reduction in pain intensity from 6.0±1.6 to 2.2±0.4 (p<0.001), and an improvement in jaw opening from 1.5±0.5 cm to 4.3±0.6 cm (p<0.001). No statistically significant differences between two groups were detected. Conclusions The results of this three-year prospective study support the surgical placement of TMJ prostheses (stock prosthetic, and custom-made systems), and show that the approach is efficacious and safe, reduces pain, and improves maximum mouth opening movement, with few complications. As such, TMJR represents a viable technique and a stable long-term solution for cranio-mandibular reconstruction in patients with irreversible end-stage TMJ disease. Comparing stock and custom-made groups, no statistically significant differences were detected with respect to pain intensity reduction and maximum mouth opening improvement. Key words:Temporo-mandibular joint, temporo-mandibular joint replacement, prosthesis, biomaterials, biomedical engineering, computer-aided design and manufacturing. PMID:27475697
Design and validation of a real-time spiking-neural-network decoder for brain-machine interfaces
NASA Astrophysics Data System (ADS)
Dethier, Julie; Nuyujukian, Paul; Ryu, Stephen I.; Shenoy, Krishna V.; Boahen, Kwabena
2013-06-01
Objective. Cortically-controlled motor prostheses aim to restore functions lost to neurological disease and injury. Several proof of concept demonstrations have shown encouraging results, but barriers to clinical translation still remain. In particular, intracortical prostheses must satisfy stringent power dissipation constraints so as not to damage cortex. Approach. One possible solution is to use ultra-low power neuromorphic chips to decode neural signals for these intracortical implants. The first step is to explore in simulation the feasibility of translating decoding algorithms for brain-machine interface (BMI) applications into spiking neural networks (SNNs). Main results. Here we demonstrate the validity of the approach by implementing an existing Kalman-filter-based decoder in a simulated SNN using the Neural Engineering Framework (NEF), a general method for mapping control algorithms onto SNNs. To measure this system’s robustness and generalization, we tested it online in closed-loop BMI experiments with two rhesus monkeys. Across both monkeys, a Kalman filter implemented using a 2000-neuron SNN has comparable performance to that of a Kalman filter implemented using standard floating point techniques. Significance. These results demonstrate the tractability of SNN implementations of statistical signal processing algorithms on different monkeys and for several tasks, suggesting that a SNN decoder, implemented on a neuromorphic chip, may be a feasible computational platform for low-power fully-implanted prostheses. The validation of this closed-loop decoder system and the demonstration of its robustness and generalization hold promise for SNN implementations on an ultra-low power neuromorphic chip using the NEF.
[Artificial sight: recent developments].
Zeitz, O; Keserü, M; Hornig, R; Richard, G
2009-03-01
The implantation of electronic retina stimulators appears to be a future possibility to restore vision, at least partially in patients with retinal degeneration. The idea of such visual prostheses is not new but due to the general technical progress it has become more likely that a functioning implant will be on the market soon. Visual prosthesis may be integrated in the visual system in various places. Thus there are subretinal and epiretinal implants, as well as implants that are connected directly to the optic nerve or the visual cortex. The epiretinal approach is the most promising at the moment, but the problem of appropriate modulation of the image information is unsolved so far. This will be necessary to provide a interpretable visual information to the brain. The present article summarises the concepts and includes some latest information from recent conferences.
Weiss, Christine
2007-01-01
Today microsystems are important for the prevention, diagnosis and therapy of diseases. Physicians use small endoscopes for minimally invasive surgery. Patients regain their mobility by high-tech prostheses equipped with several sensors and actuators. Intelligent implants such as pacemakers support existential functions. Cochlea-implants enable deaf persons to hear. Safe convalescence at home is possible by tele-monitoring devices. Point-of-care such as biochips supply quick diagnostic results. A number of these remarkable developments have been successfully supported by the German Federal Ministry of Education and Research (BMBF) since 1990.
Travancas, Paulo R; Dorigo, Ana H; Simões, Luiz C; Fonseca, Sandra C; Bloch, Kátia V; Herdy, Gesmar V
2009-04-01
To assess the outcomes in children and adolescents with rheumatic fever of the implantation of mechanical as opposed to biological heart valves. We assessed 73 patients with rheumatic heart disease under the age of 18 years, who underwent replacement of heart valves between January, 1996, and December, 2005, at the National Institute of Cardiology in Rio de Janeiro, Brazil. Of the group, 71 patients survived, and were divided into a group of 52 receiving mechanical prostheses, and 19 with biological prostheses. We compared endpoints between the groups in terms of mortality, reoperation, haemorrhage, and stroke. Survival curves were estimated using the Kaplan-Meier method and were compared by the Mantel (log-rank) test. Overall mortality was 8.2%. In those receiving mechanical prostheses, 2 (3.8%) patients died, 5 (9.6%) underwent reoperation, 2 (3.8%) suffered severe haemorrhage, and 3 (5.8%) had strokes. In those receiving biological valves, 2 (10.5%) patients died, and 4 (21%) underwent reoperation. After 2, 4, and 8 years, overall survival was 96%, 93% and 86%, respectively, with a borderline difference between the groups (p = 0.06). The probabilities of remaining free from reoperation (p = 0.13), and from combined endpoints, showed no statistically significant difference between the groups (p = 0.28). Patients with mechanical prostheses had lower mortality and required fewer reoperations, but when all combined endpoints were considered, the groups did not differ. The biological prosthesis proved to be a good option for cardiac surgery in children and adolescents with difficulties or risks of anticoagulation.
Chung, Eric
2017-02-01
Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.
2017-01-01
Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades. PMID:28217449
Rehabilitation with implant-supported overdentures in total edentulous patients: A review
Segura-Andrés, Gustavo; Faus-López, Joan; Agustín-Panadero, Rubén
2013-01-01
Objectives: The main aim of this review article is to discuss implant-supported overdentures (ISOs) as treatment in edentulous patients. Besides, we will try to discuss among the different treatment options in such patients and to analyze their validity when ISOs are compared with other clinical modalities. At the same time, we will try to suggest clinical guidelines supported by current clinical studies. Material and methods: We performed a Medline search and review of pertinent articles on the mentioned subject from 1986 to 2011. As a searching strategy, we used the following words: implant-supported overdentures, attachment systems, Locator attachment, cantilever, fixed prosthesis. Results and conclusions: Implant-supported overdentures constitute an accurate and predictable treatment option and achieve a higher patients’ satisfaction. This type of treatment constitutes a cheaper treatment than fixed prostheses and in some patients, with loss of lip support or with an interoclusal space larger than 15 mm, the choice of implant-supported overdentures seems to prevent future aesthetic or phonetic problems. Key words:Overdentures, implant occlusion, implant rehabilitation, total edentulous rehabilitation, fixed prosthesis. PMID:24455093
Minoda, Yukihide; Hata, Kanako; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki
2017-09-01
Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee. Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser. The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 × 10 7 counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 × 10 7 counts/knee), the difference was not statistically significant. The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation. Therapeutic study, Level III.
Willing, Ryan; Lapner, Michael; King, Graham J W; Johnson, James A
2014-11-01
Distal humeral hemiarthroplasty alters cartilage contact mechanics, which may predispose to osteoarthritis. Current prostheses do not replicate the native anatomy, and therefore contribute to these changes. We hypothesized that prostheses reverse-engineered from the native bone shape would provide similar contact patterns as the native articulation. Reverse-engineered hemiarthroplasty prostheses were manufactured for five cadaveric elbows based on CT images of the distal humerus. Passive flexion trials with constant muscle forces were performed with the native articulation intact while bone motions were recorded using a motion tracking system. Motion trials were then repeated after the distal humerus was replaced with a corresponding reverse-engineered prosthesis. Contact areas and patterns were reconstructed using computer models created from CT scan images combined with the motion tracker data. The total contact areas, as well as the contact area within smaller sub-regions of the ulna and radius, were analyzed for changes resulting from hemiarthroplasty using repeated-measures ANOVAs. Contact area at the ulna and radius decreased on average 42% (SD 19%, P=.008) and 41% (SD 42%, P=.096), respectively. Contact area decreases were not uniform throughout the different sub-regions, suggesting that contact patterns were also altered. Reverse-engineered prostheses did not reproduce the same contact pattern as the native joints, possibly because the thickness of the distal humerus cartilage layer was neglected when generating the prosthesis shapes or as a consequence of the increased stiffness of the metallic implants. Alternative design strategies and materials for hemiarthroplasty should be considered in future work. Copyright © 2014 Elsevier Ltd. All rights reserved.
Al-Magaleh, Wafaʼa R; Abbas, Nadia A; Amer, Ashraf A; Abdelkader, Ann A; Bahgat, Basma
2016-04-01
This study aimed to investigate the relation between biting force and masticatory muscle activity in patients treated by 3 modalities of single mandibular dentures. Forty implants were placed in 10 patients with completely edentulous mandibles. The study was divided into 3 treatment stages. Initially, each patient received a conventional mandibular complete denture. At the second stage, 4 mandibular implants were placed and the denture was refitted to their abutments. Third stage comprised connecting the denture to the implants through ball attachments. During each treatment stage, maximum biting force and muscle activity were measured during maximum clenching and chewing of soft and hard food. Biting force demonstrated a statistically significant increase by time for the 3 treatment stages. The highest muscle activity was recorded for the conventional denture followed by the implant-supported overdenture without attachment, whereas the lowest values were recorded for the implant-supported overdenture with attachment. Biting force was related mainly to the quality of denture support. Muscle activity was higher in patients with conventional denture than with implant-supported prostheses (with or without attachments).
[Osseointegration as a method of direct stabilization of amputation prostheses to the bone].
Rochmiński, Robert; Sibński, Marcin; Synder, Marek
2011-01-01
This article summarizes important advantages, disadvantages and the process of treatment of patients after lower limb amputation on the level of the femur, with osseointegrated prosthesis. In the process of treatment bone-integrated material is implanted to the femur, with allows for structural and functional connection between live tissue and the prosthesis. This solution allows the patient for easy usage and direct steerage of the prosthesis, transferring of body weight to the floor and detection of sensation in the moment of contact between prosthesis and the ground. Osseointegrated prostheses in the femur gives the opportunity not to use the traditional solutions and socket-related problems as: mobility difficulties, skin sores, rush, pain during weight bearing, temporary changes of the stump volume, difficulty donning the prosthesis, unreliability of prosthesis being securely suspended. Osseointegration is possible even in cases, when quality of skin and short stump enables to use the traditional prosthetic socket. It is used after lower and upper limbs amputations. This kind of prosthetic solutions has some disadvantages and limitations. It is expensive and demanding. It can be used in cooperative patients, who take active part in the process of implantation, rehabilitation and in future usage if the prosthesis.
Bone Repair and Military Readiness
2012-10-25
formation. Orthopedic surgeons have had to adapt surgical techniques to account for issues with cementing total joint prostheses and subsequent total joint ...the silorane composite has the potential to support osseous integration around the cemented total joint implant and may generate less immunogenic wear...factors, and potential for osseointegration/osseoinduction, this material has potential to be used for screw augmentation, total hip/knee joint
Zamani, Majid; Demosthenous, Andreas
2014-07-01
Next generation neural interfaces for upper-limb (and other) prostheses aim to develop implantable interfaces for one or more nerves, each interface having many neural signal channels that work reliably in the stump without harming the nerves. To achieve real-time multi-channel processing it is important to integrate spike sorting on-chip to overcome limitations in transmission bandwidth. This requires computationally efficient algorithms for feature extraction and clustering suitable for low-power hardware implementation. This paper describes a new feature extraction method for real-time spike sorting based on extrema analysis (namely positive peaks and negative peaks) of spike shapes and their discrete derivatives at different frequency bands. Employing simulation across different datasets, the accuracy and computational complexity of the proposed method are assessed and compared with other methods. The average classification accuracy of the proposed method in conjunction with online sorting (O-Sort) is 91.6%, outperforming all the other methods tested with the O-Sort clustering algorithm. The proposed method offers a better tradeoff between classification error and computational complexity, making it a particularly strong choice for on-chip spike sorting.
Microelectrodes with Three-Dimensional Structures for Improved Neural Interfacing
2001-10-25
highly xible bio-interfaces [2]. Polyimides combine excellent ectrical and mechanical characteristics with biocompatibility ], and are well known in...excellent biocompatibility , polyimide -based electrodes promise for fabrication of long-term implants for the use in prostheses. The flexible structures...R. R. Richardson, J. A. Miller, and W. M. Reichert, " Polyimides as Biomaterials - Preliminary Biocompatibility Testing," Biomaterials, vol. 14, pp
Gelb, David; McAllister, Bradley; Nummikoski, Pirkka; Del Fabbro, Massimo
2013-01-01
The aim of this study was to evaluate the clinical and radiographic long-term outcomes of dental implants with an anodized TiUnite surface, placed in routine clinical practice. Two clinical centers participated in the study. One hundred and seven implants (80 in the maxilla and 27 in the mandible) in 52 patients were followed in the long term. Both one- and two-stage techniques were used for 38 and 69 implants, respectively. Thirty-eight single tooth restorations and 22 fixed partial prostheses were delivered, according to a delayed loading protocol, within 4 to 12 months since implant placement. All implants were stable at insertion and at the long-term follow-up visit, which occurred between 7 and 8 years of functional loading. The mean followup was 7.33 ± 0.47 years. The mean marginal bone level change at the long-term followup as compared to baseline was 1.49 ± 1.03 mm. No implant failure occurred. Healthy peri-implant mucosa was found around 95% of implants, whereas 91% of implants showed no visible plaque at the implant surfaces at the long-term followup. The study showed that dental implants with the TiUnite anodized surface demonstrate excellent long-term clinical and radiographic outcomes. PMID:23533412
Von Der Emde J, J; Eberlein, U; Breme J, J
1990-01-01
From August 1971 through November 1972, we implanted 62 Model 2 DeBakey-Surgitool aortic valve prostheses in 62 patients, 4 of whom later had clinically asymptomatic strut fractures. In 1 case, the patient died suddenly, and autopsy revealed detachment of the ball-cage; in each of the other 3 cases, fractures of 2 struts close to the base of the prosthesis were diagnosed fluoroscopically, and the patients underwent successful reoperation. The interval between implantation and reoperation ranged from 11 months to 16 years, 9 months. In 1 patient, retrospective study of chest radiographs revealed that the fracture had been present for 2(1/2) years. Larger valves (>/= A6) were affected significantly more often than smaller ones. We performed metallurgic analysis of 1 prosthesis: results revealed strut wear from fatigue cracking and secondary abrasion. Strut fracture was also promoted by suspension of the cage at right angles to the prosthetic ring and by use of a pyrolytic carbon ball in a titanium cage (i.e., an occluder harder than its holder). Patients with DeBakey-Surgitool aortic valve prostheses should undergo annual radiologic examinations to enable early detection of strut fractures. Prophylactic valve replacement is not indicated.
Yoda, Nobuhiro; Ogawa, Toru; Gunji, Yoshinori; Vanegas, Juan R; Kawata, Tetsuo; Sasaki, Keiichi
2016-08-01
The mechanisms by which the loads exerted on implants that support prostheses are modulated during mastication remain unclear. The purpose of this study was to evaluate the effects of food texture on 3-dimensional loads measured at a single implant using a piezoelectric transducer. Two subjects participated in this study. The transducer and the experimental superstructure, which had been adjusted to the subject's occlusal scheme, were attached to the implant with a titanium screw. The foods tested were chewing gum and peanuts. The mean maximum load on the implant in each chewing cycle was significantly higher during peanut chewing than during gum chewing. The direction of maximum load was significantly more widely dispersed during peanut chewing than during gum chewing. The range of changes in load direction during the force-increasing phase of each chewing cycle was significantly wider during peanut chewing than during gum chewing. The load on the implant was affected by food texture in both subjects. This measurement method can be useful to investigate the mechanisms of load modulation on implants during mastication.
Itoh, Manabu; Nakayama, Koichi; Noguchi, Ryo; Kamohara, Keiji; Furukawa, Kojirou; Uchihashi, Kazuyoshi; Toda, Shuji; Oyama, Jun-ichi; Node, Koichi; Morita, Shigeki
2015-01-01
Background Small caliber vascular prostheses are not clinically available because synthetic vascular prostheses lack endothelial cells which modulate platelet activation, leukocyte adhesion, thrombosis, and the regulation of vasomotor tone by the production of vasoactive substances. We developed a novel method to create scaffold-free tubular tissue from multicellular spheroids (MCS) using a “Bio-3D printer”-based system. This system enables the creation of pre-designed three-dimensional structures using a computer controlled robotics system. With this system, we created a tubular structure and studied its biological features. Methods and Results Using a “Bio-3D printer,” we made scaffold-free tubular tissues (inner diameter of 1.5 mm) from a total of 500 MCSs (2.5× 104 cells per one MCS) composed of human umbilical vein endothelial cells (40%), human aortic smooth muscle cells (10%), and normal human dermal fibroblasts (50%). The tubular tissues were cultured in a perfusion system and implanted into the abdominal aortas of F344 nude rats. We assessed the flow by ultrasonography and performed histological examinations on the second (n = 5) and fifth (n = 5) day after implantation. All grafts were patent and remodeling of the tubular tissues (enlargement of the lumen area and thinning of the wall) was observed. A layer of endothelial cells was confirmed five days after implantation. Conclusions The scaffold-free tubular tissues made of MCS using a Bio-3D printer underwent remodeling and endothelialization. Further studies are warranted to elucidate the underlying mechanism of endothelialization and its function, as well as the long-term results. PMID:26325298
Comparison of the patient and partner satisfaction with 700CX and Titan penile prostheses.
Otero, Javier Romero; Cruz, César Rojas; Gómez, Borja García; Geli, Joaquim Sarquella; Polo, Jose Medina; Castañé, Eduard Ruiz; Antolín, Alfredo Rodríguez
2017-01-01
Most widespread three-component penile prosthesis models are 700CX™ and Titan ® . Our purpose is to assess patient and partner satisfaction after the first implant. This is a multicenter, retrospective, nonrandomized study in which all patients who met the inclusion criteria between 2009 and 2013 were included. In total, 248 patients agreed to participate. To evaluate patient satisfaction, a validated but modified 11-question questionnaire was completed (EDITS); and a nonvalidated two-item questionnaire was given to the partner. Statistical analysis used an ordinal logistic regression model. Two hundred and forty-eight patients (194 with 700CX™ vs 54 with Titan®) and 207 couples completed the questionnaire (165 with 700CX™ vs 42 with Titan®). Overall satisfaction was high. Both showed great reliability for sexual intercourse and high compliance with prior expectations. Most patients were able to manage the penile prosthesis correctly within 6 months. Postoperative penile shortening led to some dissatisfaction in 42% and 46% of cases (700CX™ /Titan®). Significant differences were found in three questions of patients' questionnaire. There were more patients satisfied with the 700CX™ (P = 0.0001). No patient with Titan® implant took longer than 6 months to optimal management. Only 4% of patients with 700CX™ implant were dissatisfied with the deflation, in contrast to 24% with the Titan® (P = 0.0031). Of the two partners' questions, one showed a statistically significant difference (P = 0.0026). It seems that group 700CX™ would recommend to re-implant the prosthesis with a greater tendency. The overall satisfaction was very high for both prostheses. The final aspect of the erected and flaccid penis was satisfactory, but both groups showed significant discontent with its final size. Partners' overall satisfaction was high.
Castillo-Oyagüe, Raquel; Perea, Carmen; Suárez-García, María-Jesús; Río, Jaime Del; Lynch, Christopher D; Preciado, Arelis
2016-12-01
To validate the 'Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)' questionnaire for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-supported fixed partial denture (FPD) wearers. 107 patients were assigned to: Group 1 (HP; n=37): fixed-detachable hybrid prostheses (control); Group 2 (C-PD, n=35): cemented partial dentures; and Group 3 (S-PD, n=35): screwed partial dentures. Patients answered the QoLFAST-10 and the Oral Health Impact Profile (OHIP-14sp) scales. Information on global oral satisfaction, socio-demographic, prosthetic, and clinical data was gathered. The psychometric capacity of the QoLFAST-10 was investigated. The correlations between both indices were explored by the Spearman's rank test. The effect of the study variables on the OHRQoL was evaluated by descriptive and non-parametric probes (α=0.05). The QoLFAST-10 was reliable and valid for implant-supported FPD wearers, who attained comparable results regardless of the connection system being cement or screws. Both fixed partial groups demonstrated significantly better social, functional, and total satisfaction than did HP wearers with this index. All groups revealed similar aesthetic-related well-being and consciousness about the importance of health-behavioural habits. Several study variables modulated the QoLFAST-10 scores. Hybrid prostheses represent the least predictable treatment option, while cemented and screwed FPDs supplied equal OHRQoL as estimated by the QoLFAST-10 scale. The selection of cemented or screwed FPDs should mainly rely on clinical factors, since no differences in patient satisfaction may be expected between both types of implant rehabilitations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kappel, Stefanie; Chepura, Taras; Schmitter, Marc; Rammelsberg, Peter; Rues, Stefan
To examine the in vitro effects of different cements, abutment surface preconditioning, and artificial aging on the maximum tensile force needed to detach cantilever fixed dental prostheses (FDPs) from dental implants with titanium abutments. A total of 32 tissue-level implants were combined with standardized titanium abutments. For each test group, eight cantilever FDPs were fabricated using selective laser melting (cobalt-chromium [CoCr] alloy). The inner surfaces of the cantilever FDPs and half of the abutments were sandblasted and then joined by use of four different cements (two permanent and two semi-permanent) in two different amounts per cement. Subgroups were tested after either artificial aging (thermocycling and chewing simulation) or 3 days of water storage. Finally, axial pull off-tests were performed for each abutment separately. Cement type and surface pretreatment significantly affected decementation behavior. The highest retention forces (approximately 1,200 N) were associated with sandblasted abutments and permanent cements. With unconditioned abutments, temporary cements (Fu < 100 N), as well as glass-ionomer cement (Fu ≈ 100 N), resulted in rather low retention forces. Zinc phosphate cement guaranteed high retention forces. After aging, retention was sufficient only for cementation with zinc phosphate cement and for the combination of sandblasted abutments and glass-ionomer cement. When glass-ionomer cement is used to fix cantilever FDPs on implants, sandblasting of standard titanium abutments may help prevent loss of retention. Retention forces were still high for FDPs fixed with zinc phosphate cement, even when the abutments were not pretreated. Use of permanent cements only, however, is recommended to prevent unwanted loosening of cantilever FDPs.
Malzahn, J
2014-06-01
The development of the overall achievements for hospital performance since the introduction in Germany of the diagnosis-related groups (DRG) system in 2003 is the subject of healthcare political discussion. The field of prosthetics is often at the center of considerations. After consideration of the development of achievements with international and regional earnings, the question was investigated how the average expenditure for patients with gonarthritis developed in a time period of 1 year before and after implantation of total knee prostheses. The study was based on individual patient data from the accounting data of the AOK (General Regional Healthcare Insurance) from the categories, inpatient care, panel physician treatment, pharmaceuticals and medicines as well as disability leave periods. The data include the average expenditure and disability times calculated by the AOK for individual patients 12 months before and 12 months after implantation of a total knee prosthesis. The methods were selected because the international classification of diseases (ICD) coding does not allow a differentiation in the degree of severity and, therefore, a comparison of patients who were only conservatively treated within the scope of panel physicians which would have led to problems in risk adjustment. Due to a lack of coding guidelines for treatment by panel physicians, the accuracy of the diagnosis is also limited in comparison to inpatient treatment data. The expenditure and the average disability leave for gonarthritis patients were higher in the year following implantation of total knee prostheses than in the year prior to implantation. No conclusions can be drawn from the provision of service data with respect to the quality of life of the patients. Investigations over a longer time period seem to be necessary.
Kirmanidou, Yvoni; Sidira, Margarita; Drosou, Maria-Eleni; Bennani, Vincent; Bakopoulou, Athina; Tsouknidas, Alexander; Michailidis, Nikolaos; Michalakis, Konstantinos
2016-01-01
Titanium implants are widely used in the orthopedic and dentistry fields for many decades, for joint arthroplasties, spinal and maxillofacial reconstructions, and dental prostheses. However, despite the quite satisfactory survival rates failures still exist. New Ti-alloys and surface treatments have been developed, in an attempt to overcome those failures. This review provides information about new Ti-alloys that provide better mechanical properties to the implants, such as superelasticity, mechanical strength, and corrosion resistance. Furthermore, in vitro and in vivo studies, which investigate the biocompatibility and cytotoxicity of these new biomaterials, are introduced. In addition, data regarding the bioactivity of new surface treatments and surface topographies on Ti-implants is provided. The aim of this paper is to discuss the current trends, advantages, and disadvantages of new titanium-based biomaterials, fabricated to enhance the quality of life of many patients around the world. PMID:26885506
Biomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substrates in vivo
NASA Astrophysics Data System (ADS)
Brodbeck, William G.; Patel, Jasmine; Voskerician, Gabriela; Christenson, Elizabeth; Shive, Matthew S.; Nakayama, Yasuhide; Matsuda, Takehisa; Ziats, Nicholas P.; Anderson, James M.
2002-08-01
An in vivo rat cage implant system was used to identify potential surface chemistries that prevent failure of implanted biomedical devices and prostheses by limiting monocyte adhesion and macrophage fusion into foreign-body giant cells while inducing adherent-macrophage apoptosis. Hydrophobic, hydrophilic, anionic, and cationic surfaces were used for implantation. Analysis of the exudate surrounding the materials revealed no differences between surfaces in the types or levels of cells present. Conversely, the proportion of adherent cells undergoing apoptosis was increased significantly on anionic and hydrophilic surfaces (46 ± 3.7 and 57 ± 5.0%, respectively) when compared with the polyethylene terephthalate base surface. Additionally, hydrophilic and anionic substrates provided decreased rates of monocyte/macrophage adhesion and fusion. These studies demonstrate that biomaterial-adherent cells undergo material-dependent apoptosis in vivo, rendering potentially harmful macrophages nonfunctional while the surrounding environment of the implant remains unaffected.
Hypersensitivity reactions to metal implants: laboratory options.
Carossino, Anna Maria; Carulli, Christian; Ciuffi, Simone; Carossino, Roberto; Zappoli Thyrion, Giorgia Donata; Zonefrati, Roberto; Innocenti, Massimo; Brandi, Maria Luisa
2016-11-23
All implant compounds undergo an electrochemical process when in contact with biological fluids, as well as mechanical corrosion due to abrasive wear, with production of metal debris that may inhibit repair processes. None of the commonly-used methods can diagnose implant allergies when used singly, therefore a panel of tests should be performed on allergic patients as pre-operative screening, or when a postoperative metal sensitisation is suspected. We analysed patients with painful prostheses and subjects prone to allergies using the Patch Test in comparison with the Lymphocyte Transformation Test. Cytokine production was evaluated to identify prognostic markers for early diagnosis of aseptic loosening. Metal debris endocytosis and cytoskeletal rearrangement was visualised by confocal microscopy. Our results demonstrate that the Lymphocyte Transformation Test can identify patients who have a predisposition to develop allergic reactions and can confirm the diagnosis of hypersensitivity in patients with painful prostheses. The prevalence of a Th2-cytokine pattern may be used to identify predisposition to the development of allergic diseases, while the selective presence of osteoclastogenic cytokines may be used as predictor of a negative outcome in patients with painful prosthesis. The hypothesis of the prognostic value of these cytokines as early markers of aseptic loosening is attractive, but its confirmation would require extensive testing. The Lymphocyte Transformation Test is the most suitable method for testing systemic allergies. We suggest that the combined use of the Patch Test and the Lymphocyte Transformation Test, associated with cytokine detection in selected patients, could provide a useful tool for preventive evaluation of immune reactivity in patients undergoing primary joint replacement surgery, and for clinical monitoring of the possible onset of a metal sensitization in patients with implanted devices.
Localized Cell and Drug Delivery for Auditory Prostheses
Hendricks, Jeffrey L.; Chikar, Jennifer A.; Crumling, Mark A.; Raphael, Yehoash; Martin, David C.
2011-01-01
Localized cell and drug delivery to the cochlea and central auditory pathway can improve the safety and performance of implanted auditory prostheses (APs). While generally successful, these devices have a number of limitations and adverse effects including limited tonal and dynamic ranges, channel interactions, unwanted stimulation of non-auditory nerves, immune rejection, and infections including meningitis. Many of these limitations are associated with the tissue reactions to implanted auditory prosthetic devices and the gradual degeneration of the auditory system following deafness. Strategies to reduce the insertion trauma, degeneration of target neurons, fibrous and bony tissue encapsulation, and immune activation can improve the viability of tissue required for AP function as well as improve the resolution of stimulation for reduced channel interaction and improved place-pitch and level discrimination. Many pharmaceutical compounds have been identified that promote the viability of auditory tissue and prevent inflammation and infection. Cell delivery and gene therapy have provided promising results for treating hearing loss and reversing degeneration. Currently, many clinical and experimental methods can produce extremely localized and sustained drug delivery to address AP limitations. These methods provide better control over drug concentrations while eliminating the adverse effects of systemic delivery. Many of these drug delivery techniques can be integrated into modern auditory prosthetic devices to optimize the tissue response to the implanted device and reduce the risk of infection or rejection. Together, these methods and pharmaceutical agents can be used to optimize the tissue-device interface for improved AP safety and effectiveness. PMID:18573323
Chip-scale hermetic feedthroughs for implantable bionics.
Guenther, Thomas; Dodds, Christopher W D; Lovell, Nigel H; Suaning, Gregg J
2011-01-01
Most implantable medical devices such as cochlear implants and visual prostheses require protection of the stimulating electronics. This is achieved by way of a hermetic feedthrough system which typically features three important attributes: biocompatibility with the human body, device hermeticity and density of feedthrough conductors. On the quest for building a visual neuroprosthesis, a high number of stimulating channels is required. This has encouraged new technologies with higher rates of production yield and further miniaturization. An Al(2)O(3) based feedthrough system has been developed comprising up to 20 platinum feedthroughs per square millimeter. Ceramics substrates are shown to have leak rates below 1 × 10(-12) atm × cc/s, thus exceeding the resolution limits of most commercially available leak detectors. A sheet resistance of 0.05 Ω can be achieved. This paper describes the design, fabrication process and hermeticity testing of high density feedthroughs for use in neuroprosthetic implants.
Therapeutic Challenge in a Severely Atrophic Mandible
Janev, Edvard; Janeva, Nadica; Peeva–Petreska, Marija; Mitic, Kristina
2018-01-01
BACKGROUND: After tooth loss, however, severely atrophic residual alveolar ridges are fairly common, especially in patients who have been edentulous for a long period. Anterior area of the mandible is areas where clinicians have greater anatomical limitations. Reduced alveolar bone height very often represents a contraindication to implant therapy, unless a procedure such as a ridge augmentation is performed. CASE REPORT: This study aims to present two separate cases in highly selected edentulous anterior mandibular sites, where one stage, mini implants were used to support total prostheses. Small diameter implants have been used for retention of complete removable mandibular overdentures. This is an excellent option for those who suffer from the inconvenience and embarrassment of loose lower dentures and are tired of having to use sticky pastes and creams to make their dentures stay in place. CONCLUSION: Small diameter implants, when used multiples may offer adequate support for a removable prosthesis and overcome this problem. PMID:29610621
Detection of total knee prostheses at airport security checkpoints.
Naziri, Qais; Johnson, Aaron J; Hooper, Hasan A; Sana, Said H; Mont, Michael A
2012-06-01
Airport security screening measures have changed substantially during the past decade, but few reports have examined how this affects patients who have undergone knee arthroplasties. The purpose of this study was to characterize the efficacy of airport metal detection of total knee prostheses, the delays faced, any inconvenience this may have caused, and the role of implant identification cards. Ninety-seven total knee arthroplasty recipients reported passing through an airport metal detector, with 70 triggering the alarm a mean of 3 times (range, 1-36). The presence of a single-knee prosthesis triggered airport security alarms more than 83% of the time and increased patient inconvenience. Patients should be informed about this chance and be prepared to present documentation of their prosthesis. Copyright © 2012 Elsevier Inc. All rights reserved.
Polyethylene wear debris in modular acetabular prostheses.
Chen, P C; Mead, E H; Pinto, J G; Colwell, C W
1995-08-01
The longevity of total hip arthroplasty has brought forth the recognition of aseptic loosening of prosthetic components as the leading cause of implant failure. Modularity of implants, although a significant improvement in versatility, may increase debris formation, a recognized cause of implant failure. This study was designed to measure the relative motion, and to assess the polyethylene wear debris production at the interface between the metal acetabular shell and the back side of the polyethylene liner, in modular hip prostheses. Five models from 4 manufacturers with different locking mechanisms and acetabular shell surface treatments were tested under long-term simultaneous sinusoidal and static loading (10(7) cycles at 3 Hz with +/- 2.5 Nmeter and 220 N static load). Results showed that there were marked differences in the security of the acetabular shell and polyethylene liner locking mechanism, wear pattern, damage sites, and amount of polyethylene debris on the acetabular shell and polyethylene liner surfaces. The range of polyethylene liner motion observed among the 5 models during 1 cycle of testing varied from an average of 0.96 degrees to movement too small to be detected by the test machines. Image and scanning electron microscopy analysis showed different wear patterns and a wide range in the average polyethylene liner surface wear area (0.26 cm2-4.61 cm2). In general, a stable locking mechanism and a smooth acetabular shell surface are essential in minimizing polyethylene liner wear and polyethylene debris production.
Goldstein, I; Newman, L; Baum, N; Brooks, M; Chaikin, L; Goldberg, K; McBride, A; Krane, R J
1997-03-01
We investigated safety and efficacy outcome pertaining to the Mentor Alpha-1, 3-piece inflatable penile prosthesis for impotence treatment. A 2-phase, multi-institutional, large scale retrospective study, with independently analyzed medical record (phase I) and questionnaire (phase II) data from consecutive eligible patients of 7 physician investigators was performed from March to October 1993. In phase I there were no morbidities of any type in 394 of the 434 patients (90.8%) (mean age 61 years, range 24 to 88) who underwent Alpha-1 implantation (mean followup 22.2 months, range 0.67 to 44.5). The risk of prosthesis malfunction (fluid leak and auto-inflation) was 2.5%. No cylinder aneurysms were reported. A total of 93.1% of Alpha-1 devices was free from explantation (4.4%) or revision surgery (2.5%) for approximately 2 years from the original implant date. Kaplan-Meier actuarial analyses revealed that cumulative survival of the Alpha-1 prostheses at 12, 24 and 36 months was 98 +/- 1%, 93 +/- 2% and 85 +/- 7% until device malfunction, and 91 +/- 2% 83 +/- 4% and 75 +/- 7% until surgical intervention (revision or explantation). In phase II 89% of the men claimed fulfilled expectations with the Alpha-1 prosthesis as impotence treatment. Satisfaction responses 80% or greater were noted with regard to intercourse ability and confidence, and device rigidity and function. Implantation did not result in greater than 80% satisfaction in partner relationships or feelings (as judged by the patient), social or work confidence, or intercourse frequency. Factors adversely affecting satisfaction included partner feelings of dissatisfaction (as judged by the patient), specific physician investigators and need for explantation/revision surgery. In 1 of the largest multi-institutional implant outcome studies thus far performed, safety and efficacy data concerning the Alpha-1 contemporary inflatable device were found markedly improved over earlier inflatable prostheses and now compare favorably with historical data from noninflatable rod type devices.
Longterm infrared neural stimulation in the chronic implanted cat
NASA Astrophysics Data System (ADS)
Matic, Agnella Izzo; Robinson, Alan M.; Young, Hunter K.; Badofsky, Ben; Rajguru, Suhrud M.; Richter, Claus-Peter
2013-03-01
Among neural prostheses cochlear implants (CIs) are considered the most successful devices. They restore some hearing to 210,000 severe-to-profound hearing impaired people. Despite the devices' success, the performance of the implanted individuals in noisy environments is poor and music perception is rudimentary. It has been argued that increasing the number of independent channels for stimulation can improve the performance of a CI user in challenging hearing environments. An optical method, stimulating neurons with infrared radiation, has been suggested as a novel approach to increase the number of independent channels. Infrared neural stimulation (INS) works through the deposition of heat into the tissue. Thermal damage is therefore a potential risk, particularly for longterm exposure. To verify the efficacy and safety of INS, cats were implanted for about 4 weeks and were continuously stimulated daily for 6-8 hours. Cochlear function did not change during the stimulation, and histology did not reveal signs of damage. Tissue growth following the implantation was largely localized at the cochleostomy.
de Negreiros, Wagner Araujo; Verde, Marcus Aurelio Rabelo Lima; da Silva, Antonio Materson; Pinto, Lecio Pitombeira
2012-04-01
This clinical report shows the use of extraoral implants to rehabilitate an ocular defect, focusing the surgical and prosthetic procedures. Using local anesthesia and a surgical template obtained from the diagnostic wax ocular pattern, two cylinder dental implants were strategically placed in the lateral aspect of the right infraorbital region. Four months later, an acrylic framework including two spherical magnets was made using plastic UCLA abutments. After casting laboratory steps, a customized silicon prosthetic appliance was fabricated from the diagnostic wax ocular pattern and attached to the Co-Cr framework, observing its profile and seating aspects. The patient was satisfied with the treatment result, due to the retention, esthetics, and adhesive-free method to anchor his ocular prostheses. © 2012 by the American College of Prosthodontists.
Ashbaugh, Alyssa G.; Jiang, Xuesong; Zheng, Jesse; Tsai, Andrew S.; Kim, Woo-Shin; Thompson, John M.; Miller, Robert J.; Shahbazian, Jonathan H.; Wang, Yu; Dillen, Carly A.; Ordonez, Alvaro A.; Chang, Yong S.; Jain, Sanjay K.; Jones, Lynne C.; Sterling, Robert S.; Mao, Hai-Quan; Miller, Lloyd S.
2016-01-01
Bacterial biofilm formation is a major complication of implantable medical devices that results in therapeutically challenging chronic infections, especially in cases involving antibiotic-resistant bacteria. As an approach to prevent these infections, an electrospun composite coating comprised of poly(lactic-coglycolic acid) (PLGA) nanofibers embedded in a poly(ε-caprolactone) (PCL) film was developed to locally codeliver combinatorial antibiotics from the implant surface. The release of each antibiotic could be adjusted by loading each drug into the different polymers or by varying PLGA:PCL polymer ratios. In a mouse model of biofilm-associated orthopedic-implant infection, three different combinations of antibiotic-loaded coatings were highly effective in preventing infection of the bone/joint tissue and implant biofilm formation and were biocompatible with enhanced osseointegration. This nanofiber composite-coating technology could be used to tailor the delivery of combinatorial antimicrobial agents from various metallic implantable devices or prostheses to effectively decrease biofilm-associated infections in patients. PMID:27791154
Brooks, R A; Sharpe, J R; Wimhurst, J A; Myer, B J; Dawes, E N; Rushton, N
2000-05-01
We used a rat model in vivo to study the effects of the concentration of polyethylene particles on the bone-implant interface around stable implants in the proximal tibia. Intra-articular injections of 10(4), 10(6) or 10(8) high-density polyethylene (HDPE) particles per joint were given 8, 10 and 12 weeks after surgery. The animals were killed after 14 and 26 weeks and the response at the interface determined. Fibrous tissue was seen at the bone-implant interface when the head of the implant was flush with the top of the tibia but not when it was sunk below the tibial plateau. In the latter case the implant was completely surrounded by a shell of bone. The area of fibrous tissue and that of the gap between the implant and bone was related to the concentration of particles in the 14-week group (p < 0.05). Foreign-body granulomas containing HDPE particles were seen at the bone-implant interface in animals given 10(8) particles. The pathology resembles that seen around prostheses with aseptic loosening and we suggest that this is a useful model by which to study this process.
The accuracy and precision of radiostereometric analysis in upper limb arthroplasty.
Ten Brinke, Bart; Beumer, Annechien; Koenraadt, Koen L M; Eygendaal, Denise; Kraan, Gerald A; Mathijssen, Nina M C
2017-06-01
Background and purpose - Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. Patients and methods - PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA Results - 23 studies were included. Precision values were in the 0.06-0.88 mm and 0.05-10.7° range for the shoulder, the 0.05-0.34 mm and 0.16-0.76° range for the elbow, and the 0.16-1.83 mm and 11-124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. Interpretation - RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies.
Liu, Yu; Lu, Tao; Zhang, Yongxing; Qiao, Yulei; Xi, Junjie; Wang, Qun
2016-11-01
Artificial tracheas fabricated from collagen-conjugated mesh appear to overcome fatal postoperative complications, namely anastomotic dehiscence and prosthesis dislocation. Such prostheses are incorporated by host tissue, provided they are wrapped in omentum (necessitating an additional abdominal procedure) and a silicone tube is used as a stent (to be extracted several weeks postoperatively). To mitigate related host impact (i.e. injury, pain and distress), we investigated the feasibility of implanting this type of tracheal prosthesis (∼5 cm in length) alone, without omental wrapping and use of a silicone stent. Porous-type tracheal prostheses that were reinforced with a continuous polypropylene spiral and sealed by collagen sponge from porcine skin replaced segments of cervical trachea (∼5 cm long) in 10 dogs through the method of telescopic anastomosis. Omental wrapping and silicone stent placement were omitted. Postoperatively, bronchoscopic examination was performed periodically. When dogs died or were sacrificed, tracheal prostheses were harvested for haematoxylin and eosin staining and electron microscopic scanning of luminal surface conditions. With the exception of one death from an anaesthesia-related incident during fibre-optic bronchoscopy (postsurgical week 1), nine dogs survived uneventfully (until sacrifice), without prosthesis dislocation or anastomotic dehiscence. The longest observation period was 2 years and 8 months. Bronchoscopic examination revealed that no stenosis or local infection was evident in the prostheses of five dogs. Moderate (n = 2) and slight (n = 2) stenoses were observed in the other four animals. All four animals survived for a long time, without dyspnoea or stridor. Histological examination showed that partial inner surface of the artificial trachea was covered with the pseudostratified ciliated epithelium. Regeneration of ciliated epithelium was also confirmed by scanning electron microscopy. This pilot study revealed that implantation of a collagen-conjugated tracheal prosthesis (∼5 cm in length) is feasible without the need for omental wrapping and silicone stenting as ancillary measures. This approach considerably simplified the surgical procedures to minimize host intrusion, which indicated a possible clinical application. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Degidi, Marco; Nardi, Diego; Morri, Alessandro; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio
2017-09-01
Fatigue behavior of the titanium bars is of utmost importance for the safe and reliable operation of dental implants and prosthetic constructions based on these implants. To date, however, only few data are available on the fatigue strength of dental prostheses made with electric resistance welding and laser welding techniques. This in-vitro study highlighted that although the joints made with the laser welding approach are credited of a superior tensile strength, joints made with electric resistance welding exhibited double the minimum fatigue strength with respect to the joints made with laser welding (120 vs 60 N).
Olmos-Zuñiga, J. Raúl; Jasso-Victoria, Rogelio; Gaxiola-Gaxiola, Miguel; Sotres-Vega, Avelina; Hernández-Jiménez, Claudia; Baltazares-Lipp, Matilde; Arredondo del Bosque, Fernando; Santillan-Doherty, Patricio
2015-01-01
This study compared the use of lyophilized glutaraldehyde-preserved bovine pericardium (LGPBP), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), and Teflon felt (TF) as implants for vocal cords (VC) medialization and aimed to assess the endoscopic, macroscopic, and microscopic VC changes after medialization in a canine model. In 18 mongrel dogs, the right VC were medialized with LGPBP and the left were implanted as follows: Group I (n = 6): LGPBP and PTFE; Group II (n = 6): LGPBP and PET; Group III (n = 6): LGPBP and TF. Surgical handling of the implants was compared. Three months after surgery, macroscopic and microscopic changes of VC and implants were evaluated. LGPBP offered the best surgical handling (p = 0.005, Kruskal-Wallis). TF implants showed extrusion (p = 0.005, Kruskal-Wallis) and severe inflammation. All VC formed fibrous capsules around the implants; the ones developed by LGPBP implants were thinner (p = 0.001, ANOVA, Tukey). VC implanted with synthetic materials showed eosinophilic infiltration (p = 0.01, Kruskal-Wallis). We concluded that the LGPBP could be used as an implant for VC medialization because it is biocompatible, easy to handle and remove during surgical procedures, and nonabsorbable or extrudable and produces an inflammatory reaction similar to PTFE and PET. PMID:26075232
Olmos-Zuñiga, J Raúl; Jasso-Victoria, Rogelio; Gaxiola-Gaxiola, Miguel; Sotres-Vega, Avelina; Hernández-Jiménez, Claudia; Baltazares-Lipp, Matilde; Arredondo del Bosque, Fernando; Santillan-Doherty, Patricio
2015-01-01
This study compared the use of lyophilized glutaraldehyde-preserved bovine pericardium (LGPBP), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), and Teflon felt (TF) as implants for vocal cords (VC) medialization and aimed to assess the endoscopic, macroscopic, and microscopic VC changes after medialization in a canine model. In 18 mongrel dogs, the right VC were medialized with LGPBP and the left were implanted as follows: Group I (n = 6): LGPBP and PTFE; Group II (n = 6): LGPBP and PET; Group III (n = 6): LGPBP and TF. Surgical handling of the implants was compared. Three months after surgery, macroscopic and microscopic changes of VC and implants were evaluated. LGPBP offered the best surgical handling (p = 0.005, Kruskal-Wallis). TF implants showed extrusion (p = 0.005, Kruskal-Wallis) and severe inflammation. All VC formed fibrous capsules around the implants; the ones developed by LGPBP implants were thinner (p = 0.001, ANOVA, Tukey). VC implanted with synthetic materials showed eosinophilic infiltration (p = 0.01, Kruskal-Wallis). We concluded that the LGPBP could be used as an implant for VC medialization because it is biocompatible, easy to handle and remove during surgical procedures, and nonabsorbable or extrudable and produces an inflammatory reaction similar to PTFE and PET.
Hou, Yue-Zhong; Huang, Zhi; Ye, Hong-Qiang; Zhou, Yong-Sheng
2012-01-01
The presence of a large palatal or maxillary defect after partial or total maxillectomy for tumor, trauma or congenital deformation poses a challenge to prosthodontists, particularly when the use of an implant cannot be considered. This case report described the use of an air valve in a hollow silicone obturator to manufacture an inflatable obturator that could be extended further into undercut area to retain itself. The inflatable obturator exhibited adequate retention, stability and border sealing, thereby improving the masticatory, pronunciation and swallowing functions of patients. It may be a suitable alternative treatment option to an implant-retained obturator. PMID:22653550
Development of BION(TM) Technology for Functional Electrical Stimulation: Bidirectional Telemetry
2001-10-25
paralyzed limb , it is necessary to incorporate sensors and back telemetry to provide voluntary control and sensory feedback signals. We describe...requirements. Keywords - neural prostheses, electrical stimulation, implants, telemetry, sensors I. INTRODUCTION BIONs ( BIOnic Neurons) are modular...ents of a paralyzed limb will require a sophisticated control system that must be driven by two types of data from the patient: 1) command signals
Jokstad, Asbjørn; Shokati, Babak
2015-10-01
To assess implant:suprastructure misfit in patients with an edentulous jaw restored by an implant-retained fixed dental prosthesis (FDP) and its association with biologic and mechanical adverse events over an extensive period. Thirty patients with an edentulous mandible treated with implant-supported prosthetics before 2000 were examined clinically in 2012. Each patient had received 4 to 6 implants to retain a FDP made from acrylic and three different metal alloys, that is, Ag-Pd, Pd-Ag, and Au type IV. The implant intra-oral locations were recorded digitally by use of an intra-oral scanner, and the intaglio surface of the detached FDP was recorded using a desktop scanner. The fit was estimated by digital matching of the STL files using industrial metrological software. The average misfit was correlated with the average marginal bone loss and the prevalence of screw loosening or fractures, using the patient as the statistical unit. Over an average of 19 years (range 12 to 32), 5 implants had been lost in 4 participants (96.7% implant survival) and 8 eight prostheses (26.7%) had been remade. Anaverage misfit was 150 μm (SD 35, range 95-232, CI 138-163). An average marginal bone loss of 2.2 mm (SD = 0.7) had occurred (range 0.6 to 5.8 mm) for individual implants. The correlation between framework misfit and marginal bone loss was weak (R² = 0.04) (P = 0.29). The prostheses with a history of screw-related adverse events showed average misfit of 169 μm (SD = 32) vs. those with no history of screw-related adverse events, that is, 134 μm (SD = 30) (P = 0.005, Student's t-test). Fourteen of the 30 participants had experienced at least one incidence of screw loosening or fracture of prosthetic or abutment screw(s) over the period of follow-up. The occurrence among the frameworks fabricated with different metal alloys did not differ (P > 0.05, Fisher's exact test). Combining STL files with best-fit algorithms to appraise misfit is feasible using metrological software. The effect of misfit between the superstructures on its supporting implants up to ~230 μm on the long-term clinical outcomes appears to be minor, apart from a slightly higher risk of screw-related adverse events. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Macro design effects on stress distribution around implants: a photoelastic stress analysis.
Ozkir, Serhat Emre; Terzioglu, Hakan
2012-01-01
Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test. A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous. As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.
Jugdev, Jasvinder; Borzabadi-Farahani, Ali; Lynch, Edward
2014-01-01
To assess the effect of airborne particle abrasion of metal implant abutments on tensile bond strength (TBS) of TempBond, Retrieve, and Premier implant cements. Specimens were designed to replicate a single metal implant crown cemented to both smooth and airborne particle-abraded Osteo-Ti implant abutments with zero degrees of taper. Twenty castings were fabricated and cemented to either a smooth surface abutment (SSA) or to an airborne particle-abraded abutment (AAA). TBS was measured with a 50-kg load and a crosshead speed of 0.5 cm/min in a universal testing machine. Each cement was tested 10 times on both abutment types. The mean TBS values (standard deviations, 95% confidence intervals) of SSAs for TempBond, Retrieve, and Premier cements were 115.89 N (26.44, 96.98-134.81), 134.43 N (36.95, 108.25-160.60), and 132.51 N (55.10, 93.09-171.93), respectively. The corresponding values for AAAs were 129.69 N (30.39, 107.95-151.43), 298.67 N (80.36, 241.19-356.16), and 361.17 N (133.23, 265.86-456.48), respectively. There was no significant difference in TBS among the dental cements when used with an SSA. Air abrasion of abutments did not increase the TBS of TempBond but significantly increased crown retention with Retrieve and Premier. For SSAs, all failures were adhesive on the abutment surface; for AAAs, mostly cohesive cement failures occurred. The retention of copings cemented with Retrieve or Premier to zero-degree-taper abutments was significantly increased after airborne particle abrasion of the abutments. However, this was not significant when TempBond was used. Airborne particle abrasion of abutments and the use of Retrieve or Premier can be recommended for nonretrievable prostheses. Although TempBond functioned similarly to the two other cements in SSAs, it is advisable to limit its use to provisional prostheses; its long-term performance needs to be assessed clinically.
Zatorska, Beata; Groger, Marion; Moser, Doris; Diab-Elschahawi, Magda; Lusignani, Luigi Segagni; Presterl, Elisabeth
2017-08-01
Prosthetic implant infections caused by Staphylococcus aureus and epidermidis are major challenges for early diagnosis and treatment owing to biofilm formation on the implant surface. Extracellular DNA (eDNA) is actively excreted from bacterial cells in biofilms, contributing to biofilm stability, and may offer promise in the detection or treatment of such infections. (1) Does DNA structure change during biofilm formation? (2) Are there time-dependent differences in eDNA production during biofilm formation? (3) Is there differential eDNA production between clinical and control Staphylococcal isolates? (4) Is eDNA production correlated to biofilm thickness? We investigated eDNA presence during biofilm formation in 60 clinical and 30 control isolates of S aureus and S epidermidis. The clinical isolates were isolated from patients with infections of orthopaedic prostheses and implants: 30 from infected hip prostheses and 30 from infected knee prostheses. The control isolates were taken from healthy volunteers who had not been exposed to antibiotics and a hospital environment during the previous 3 and 12 months, respectively. Control S epidermidis was isolated from the skin of the antecubital fossa, and control S aureus was isolated from the nares. For the biofilm experiments the following methods were used to detect eDNA: (1) fluorescent staining with 4',6-diamidino-2-phenylindole (DAPI), (2) eDNA extraction using a commercial kit, and (3) confocal laser scanning microscopy for 24-hour biofilm observation using propidium iodide and concanavalin-A staining; TOTO ® -1 and SYTO ® 60 staining were used for observation and quantification of eDNA after 6 and 24 hours of biofilm formation. Additionally antibiotic resistance was described. eDNA production as observed by confocal laser scanning microscopy was greater in clinical isolates than controls (clinical isolates mean ± SD: 1.84% ± 1.31%; control mean ± SD: 1.17% ± 1.37%; p < 0.005) after 6 hours of biofilm formation. After 24 hours, the amount of eDNA was greater in biofilms of S epidermidis than in biofilms of S aureus (S aureus mean ± SD: 1.35% ± 2.0%; S epidermidis mean ± SD: 6.42% ± 10.6%; p < 0.05). Clinical isolates of S aureus and S epidermidis produced more eDNA than control isolates at 6 hours of biofilm formation. The extraction method also showed that clinical isolates produced substantially greater amounts of eDNA than controls. S aureus and S epidermidis exhibit a differential production of DNA with time. Clinical isolates associated with implant infections produce greater amounts of eDNA than controls. Future research might focus on the diagnostic value of eDNA as a surrogate laboratory marker for biofilm formation in implant infections. eDNA should be considered as a potential future diagnostic tool or even a possible target to modify biofilms for successful treatment of biofilm-associated infections.
Konan, Sujith; Rayan, Faizal; Manketelow, Andrew R J; Haddad, Fares S
2011-12-01
Infected periprosthetic fractures around total hip arthroplasties are an extremely challenging problem. We describe our experience of managing infected periprosthetic femoral fractures using interlocking long-stem femoral prostheses either as temporary functional spacers or as definitive implants. The Cannulock (Orthodesign, Christchurch, United Kingdom) uncoated stem was used in 12 cases, and the Kent hip prosthesis (Biomet Merck, Bridgend, United Kingdom), in 5 cases. Satisfactory outcome was noted in all cases, and in 11 cases, revision to a definitive stem has been undertaken after successful control of infection and fracture union. The use of interlocking stems offers a relatively appealing solution for a complex problem and avoids the complications that would be associated with resection of the entire femur or the use of large quantities of bone cement. Copyright © 2011 Elsevier Inc. All rights reserved.
Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, Dimiter; Delbeke, Jean
2016-01-01
Neural prostheses have already a long history and yet the cochlear implant remains the only success story about a longterm sensory function restoration. On the other hand, neural implants for deep brain stimulation are gaining acceptance for variety of disorders including Parkinsons disease and obsessive-compulsive disorder. It is anticipated that the progress in the field has been hampered by a combination of technological and biological factors, such as the limited understanding of the longterm behavior of implants, unreliability of devices, biocompatibility of the implants among others. While the field's understanding of the cell biology of interactions at the biotic-abiotic interface has improved, relatively little attention has been paid on the mechanical factors (stress, strain), and hence on the geometry that can modulate it. This focused review summarizes the recent progress in the understanding of the mechanisms of mechanical interaction between the implants and the brain. The review gives an overview of the factors by which the implants interact acutely and chronically with the tissue: blood-brain barrier (BBB) breach, vascular damage, micromotions, diffusion etc. We propose some design constraints to be considered in future studies. Aspects of the chronic cell-implant interaction will be discussed in view of the chronic local inflammation and the ways of modulating it. PMID:26903786
Turkyilmaz, Ilser; Asar, Neset Volkan
2017-06-01
The aim of the report is to introduce a new software and a new scanner with a noncontact laser probe and to present outcomes of computer-aided design and computer-aided manufacturing titanium frameworks using this new software and scanner with a laser probe. Seven patients received 40 implants placed using a 1-stage protocol. After all implants were planned using an implant planning software (NobelClinician), either 5 or 6 implants were placed in each edentulous arch. Each edentulous arch was treated with a fixed dental prosthesis using implant-supported complete-arch milled-titanium framework using the software (NobelProcera) and the scanner. All patients were followed up for 18 ± 3 months. Implant survival, prosthesis survival, framework fit, marginal bone levels, and maintenance requirements were evaluated. One implant was lost during the follow-up period, giving the implant survival rate of 97.5%; 0.4 ± 0.2 mm marginal bone loss was noted for all implants after 18 ± 3 months. None of the prostheses needed a replacement, indicating the prosthesis success rate of 100%. The results of this clinical study suggest that titanium frameworks fabricated using the software and scanner presented in this study fit accurately and may be a viable option to restore edentulous arches.
Goh, B T; Teoh, K H
2015-05-01
Surgical implant placement in the orbital region for the support of a prosthesis is challenging due to the thin orbital rim and proximity to vital structures. This article reports the use of a computer-aided design and manufacturing (CAD/CAM) stereolithographic surgical template protocol for orbital implant placement in four patients, who were followed-up for about 7 years. A total of 11 orbital implants were inserted, eight of these in irradiated bone. No intraoperative complications were noted in any of the patients and the implants were all inserted in the planned positions. The survival rate of implants placed in irradiated bone that received hyperbaric oxygen therapy was 62.5% (5/8). One implant failed in a burns injury patient at 74 months after functional loading. The overall survival of implants in the orbital region and the cumulative survival at 7 years was 63.6%. With regard to skin reactions around the abutments, 85% were grade 0, 13% were grade 1, and 2% were grade 2 according to the Holgers classification. The mean survival time of the first prosthesis was 49 months. High patient satisfaction was achieved with the implant-retained orbital prostheses. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Kelly, N; Cawley, D T; Shannon, F J; McGarry, J P
2013-11-01
The stress distribution and plastic deformation of peri-prosthetic trabecular bone during press-fit tibial component implantation in total knee arthroplasty is investigated using experimental and finite element techniques. It is revealed that the computed stress distribution, implantation force and plastic deformation in the trabecular bone is highly dependent on the plasticity formulation implemented. By incorporating pressure dependent yielding using a crushable foam plasticity formulation to simulate the trabecular bone during implantation, highly localised stress concentrations and plastic deformation are computed at the bone-implant interface. If the pressure dependent yield is neglected using a traditional von Mises plasticity formulation, a significantly different stress distribution and implantation force is computed in the peri-prosthetic trabecular bone. The results of the study highlight the importance of: (i) simulating the insertion process of press-fit stem implantation; (ii) implementing a pressure dependent plasticity formulation, such as the crushable foam plasticity formulation, for the trabecular bone; (iii) incorporating friction at the implant-bone interface during stem insertion. Simulation of the press-fit implantation process with an appropriate pressure dependent plasticity formulation should be implemented in the design and assessment of arthroplasty prostheses. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis
2016-01-01
Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356
Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis
2016-01-01
Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.
Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto
2012-05-01
Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.
Cochlear implantation in children and adults in Switzerland.
Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H J
2014-02-04
The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.
Mosavar, Alireza; Nili, Monireh; Hashemi, Sayed Raouf; Kadkhodaei, Mahmoud
2017-06-01
Depending on esthetic, anatomical, and functional aspects, in implant-prosthetic restoration of a completely edentulous jaw, the selection of implant type is highly important; however, bone- and tissue-level implants and their stress distribution in bone have not yet been comparatively investigated. Hence, finite element analysis was used to study the influence of cantilever length in a fixed prosthesis on stress distribution in peri-implant bone around these two types of oral implants. A 3D edentulous mandible was modeled. In simulations, a framework with four posterior cantilever lengths and two types of implants, bone-level and tissue-level, was considered. A compressive load was applied to the distal regions of the cantilevers, and the von-Mises stress of peri-implant bone was investigated. The independent t-test and the Pearson correlation coefficient analyzed the results (α = 0.05). Stresses in the cortical bone around the bone-level implants were greater than those in the tissue-level implants with the same cantilever length. In addition, by extending the cantilever length, the stress values in peri-implant bone increased. Therefore, when the cantilever was at its maximum length, the maximum stress was in cortical bone and around the bone-level distal implants. The results of the present study indicate that treatment with tissue-level implants is potentially more advantageous than with bone-level implants for implant-supported fixed prostheses. © 2015 by the American College of Prosthodontists.
Evaluation of direct and indirect additive manufacture of maxillofacial prostheses.
Eggbeer, Dominic; Bibb, Richard; Evans, Peter; Ji, Lu
2012-09-01
The efficacy of computer-aided technologies in the design and manufacture of maxillofacial prostheses has not been fully proven. This paper presents research into the evaluation of direct and indirect additive manufacture of a maxillofacial prosthesis against conventional laboratory-based techniques. An implant/magnet-retained nasal prosthesis case from a UK maxillofacial unit was selected as a case study. A benchmark prosthesis was fabricated using conventional laboratory-based techniques for comparison against additive manufactured prostheses. For the computer-aided workflow, photogrammetry, computer-aided design and additive manufacture (AM) methods were evaluated in direct prosthesis body fabrication and indirect production using an additively manufactured mould. Qualitative analysis of position, shape, colour and edge quality was undertaken. Mechanical testing to ISO standards was also used to compare the silicone rubber used in the conventional prosthesis with the AM material. Critical evaluation has shown that utilising a computer-aided work-flow can produce a prosthesis body that is comparable to that produced using existing best practice. Technical limitations currently prevent the direct fabrication method demonstrated in this paper from being clinically viable. This research helps prosthesis providers understand the application of a computer-aided approach and guides technology developers and researchers to address the limitations identified.
Probing the Electrode–Neuron Interface With Focused Cochlear Implant Stimulation
Bierer, Julie Arenberg
2010-01-01
Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode–neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode–neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception. PMID:20724356
Cochlear implants: system design, integration, and evaluation.
Zeng, Fan-Gang; Rebscher, Stephen; Harrison, William; Sun, Xiaoan; Feng, Haihong
2008-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
[Technology of cementless hip endoprosthetics].
Ungethüm, M; Blömer, W
1987-06-01
The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.
Hu, Gangfeng; Wang, Hui; Yao, Xiaocong; Bi, Dawei; Zhu, Gang; Tang, Songchao; Wei, Jie; Yang, Lili; Tong, Peijian; Xiao, Luwei
2014-01-01
Fluorapatite with low solubility is a promising biomaterial due to its structure, which is similar to hydroxyapatite. In this study a bioactive composite of nanofluorapatite (n-FA) and polyamide 12 (PA12) was fabricated. The results revealed that the mechanical properties (such as compressive strength and elastic modulus), hydrophilicity, and antibacterial properties of n-FA/PA12 composite were obviously improved by adding n-FA into PA12 as compared with PA12. In addition, cell proliferation of MC3T3-E1 cells cultured on n-FA/PA12 composite was significantly higher than with PA12, and alkaline phosphatase activity of MC3T3-E1 cells on the n-FA/PA12 composite was expressed at obviously higher levels as compared with PA12. The results suggest that n-FA/PA12 composite could support cell proliferation and differentiation, showing good cytocompatibility. Histological evaluation indicates that n-FA/PA12 composite enhances the efficiency of new bone formation with the introduction of n-FA into PA12, and the quantity of the newly formed bone for n-FA/PA12 composite is significantly higher than with PA12. In conclusion, n-FA/PA12 composite exhibits good biocompatibility and osteogenesis, which might be used for various orthopedic prostheses and dental implants. PMID:25143735
2009-01-01
Introduction Silicone lymphadenopathy is a rare but recognised complication of procedures involving the use of silicone. It has a poorly understood mechanism but is thought to occur following the transportation of silicone particles from silicone-containing prostheses to lymph nodes by macrophages. Case presentation We report of a case involving a 35-year-old woman who presented to the breast clinic with a breast lump and altered sensation below her left nipple 5 years after bilateral cosmetic breast augmentations. A small lump was detected inferior to the nipple but clinical examination and initial ultrasound investigation showed both implants to be intact. However, mammography and magnetic resonance imaging of both breasts revealed both intracapsular and extracapsular rupture of the left breast prosthesis. The patient went on to develop a flu-like illness and tender lumps in the left axilla and right mastoid regions. An excision biopsy of the left axillary lesion and replacement of the ruptured implant was performed. Subsequent histological analysis showed that the axillary lump was a lymph node containing large amounts of silicone. Conclusion The exclusion of malignancy remains the priority when dealing with lumps in the breast or axilla. Silicone lymphadenopathy should however be considered as a differential diagnosis in patients in whom silicone prostheses are present. PMID:19830102
Prosthetic metal implants and airport metal detectors.
Ismail, A; Dancey, A; Titley, O G
2013-04-01
Metal detectors have been present in airports and points of departure for some time. With the introduction of heightened security measures in response to fears of an increased threat of terrorism, they may become more prevalent in other public locations. The aim of this study was to ascertain which prosthetic devices activated metal detector devices used for security purposes. A range of prosthetic devices used commonly in orthopaedic and plastic surgery procedures were passed through an arch metal detector at Birmingham Airport in the UK. Additionally, each item was passed under a wand detector. Items tested included expandable breast prostheses, plates used in wrist and hand surgery, screws, K-wires, Autosuture™ ligation clips and staples. No prostheses were detected by the arch detector. The expandable implants and wrist plates were the only devices detected by passing the wand directly over them. No device was detected by the wand when it was under cover of the axillary soft tissue. Screws, K-wires, Autosuture™ clips and staples were not detected under any of the study conditions. Although unlikely to trigger a detector, it is possible that an expandable breast prosthesis or larger plate may do so. It is therefore best to warn patients of this so they can anticipate detection and further examination.
Prosthetic metal implants and airport metal detectors
Dancey, A; Titley, OG
2013-01-01
Introduction Metal detectors have been present in airports and points of departure for some time. With the introduction of heightened security measures in response to fears of an increased threat of terrorism, they may become more prevalent in other public locations. The aim of this study was to ascertain which prosthetic devices activated metal detector devices used for security purposes. Methods A range of prosthetic devices used commonly in orthopaedic and plastic surgery procedures were passed through an arch metal detector at Birmingham Airport in the UK. Additionally, each item was passed under a wand detector. Items tested included expandable breast prostheses, plates used in wrist and hand surgery, screws, K-wires, Autosuture™ ligation clips and staples. Results No prostheses were detected by the arch detector. The expandable implants and wrist plates were the only devices detected by passing the wand directly over them. No device was detected by the wand when it was under cover of the axillary soft tissue. Screws, K-wires, Autosuture™ clips and staples were not detected under any of the study conditions. Conclusions Although unlikely to trigger a detector, it is possible that an expandable breast prosthesis or larger plate may do so. It is therefore best to warn patients of this so they can anticipate detection and further examination. PMID:23827294
Vallejo Valdezate, Luis A; Hidalgo Otamendi, Antonio; Hernández, Alberto; Lobo, Fernando; Gil-Carcedo Sañudo, Elisa; Gil-Carcedo García, Luis M
2015-01-01
Many designs of prostheses are available for middle ear surgery. In this study we propose a design for a new prosthesis, which optimises mechanical performance in the human middle ear and improves some deficiencies in the prostheses currently available. Our objective was to design and assess the theoretical acoustic-mechanical behaviour of this new total ossicular replacement prosthesis. The design of this new prosthesis was based on an animal model (an iguana). For the modelling and mechanical analysis of the new prosthesis, we used a dynamic 3D computer model of the human middle ear, based on the finite elements method (FEM). The new malleovestibulopexy prosthesis design demonstrates an acoustical-mechanical performance similar to that of the healthy human middle ear. This new design also has additional advantages, such as ease of implantation and stability in the middle ear. This study shows that computer simulation can be used to design and optimise the vibroacoustic characteristics of middle ear implants and demonstrates the effectiveness of a new malleovestibulopexy prosthesis in reconstructing the ossicular chain. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Jeyapalina, Sujee; Beck, James Peter; Bachus, Kent N; Chalayon, Ornusa; Bloebaum, Roy D
2014-10-01
Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.
Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.
Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio
2013-06-25
From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.
NASA Astrophysics Data System (ADS)
Gupta, Sumit; Loh, Kenneth J.
2017-04-01
The main objective of this research is to develop a noncontact and noninvasive method for monitoring infections at the interface of human tissue and osseointegrated prostheses. The technique used here is centered on the theory of a noncontact permittivity imaging technique known as electrical capacitance tomography (ECT). This work is divided into two main parts. First, an ECT electrical permittivity reconstruction software and hardware system was developed. Second, a carbon nanotube-polyaniline nanocomposite thin film was designed and fabricated such that its electrical permittivity is sensitive to pH stimuli. The dielectric properties of this thin film were characterized as it was exposed to different pH buffer solutions. It is envisioned that osseointegrated implants can be pre-coated with the pH-sensitive nanocomposite prior to implant. When infection occurs and alters the local pH of tissue at the human-prosthesis interface, the dielectric property of the film would change accordingly. Then, ECT can interrogate the cross-section of the human limb and reconstruct its permittivity distribution, revealing localized changes in permittivity due to infection. To validate this concept, a prosthesis phantom was coated with the nanocomposite pH sensor and then immersed in different pH buffer solutions. ECT was conducted, and the results showed that the magnitude and location of subsurface, localized, pH changes could be detected. In general, noncontact tomography coupled with stimuliresponsive thin films could pave way for new modalities of noninvasive human body imaging, in particular, for patients with osseointegrated implants and prostheses.
High performance 3-coil wireless power transfer system for the 512-electrode epiretinal prosthesis.
Zhao, Yu; Nandra, Mandheerej; Yu, Chia-Chen; Tai, Yu-chong
2012-01-01
The next-generation retinal prostheses feature high image resolution and chronic implantation. These features demand the delivery of power as high as 100 mW to be wireless and efficient. A common solution is the 2-coil inductive power link, used by current retinal prostheses. This power link tends to include a larger-size extraocular receiver coil coupled to the external transmitter coil, and the receiver coil is connected to the intraocular electrodes through a trans-sclera trans-choroid cable. In the long-term implantation of the device, the cable may cause hypotony (low intraocular pressure) and infection. However, when a 2-coil system is constructed from a small-size intraocular receiver coil, the efficiency drops drastically which may induce over heat dissipation and electromagnetic field exposure. Our previous 2-coil system achieved only 7% power transfer. This paper presents a fully intraocular and highly efficient wireless power transfer system, by introducing another inductive coupling link to bypass the trans-sclera trans-choroid cable. With the specific equivalent load of our customized 512-electrode stimulator, the current 3-coil inductive link was measured to have the overall power transfer efficiency around 36%, with 1-inch separation in saline. The high efficiency will favorably reduce the heat dissipation and electromagnetic field exposure to surrounding human tissues. The effect of the eyeball rotation on the power transfer efficiency was investigated as well. The efficiency can still maintain 14.7% with left and right deflection of 30 degree during normal use. The surgical procedure for the coils' implantation into the porcine eye was also demonstrated.
Cobalt-chromium alloys in fixed prosthodontics in Sweden
Kassapidou, Maria; Franke Stenport, Victoria; Hjalmarsson, Lars; Johansson, Carina B.
2017-01-01
Abstract Aim: The aim of this study was to compile the usage of Co-Cr alloys in fixed prosthodontics (FP) among dental laboratories in Sweden. Methods: From March to October 2015, questionnaires were sent to 542 registered dental laboratories in Sweden. The questionnaires were divided in two parts, one for fixed dental-supported prosthodontics (FDP) and one for fixed implant-supported prosthodontics (FIP). Reminders were sent three times. Results: In total of 542 dental laboratories, 55% answered the questionnaires. Most dental laboratories use Co-Cr in FP, 134 (74%) in FDP and 89(66%) in FIP. The laboratories used Co-Cr alloys of various compositions in the prostheses, 35 for FDP and 30 for FIP. The most commonly used Co-Cr alloys for tooth-supported FDPs were (a) Wirobond® 280, (b) Cara SLM and (c) Wirobond® C. For implant-supported frameworks the frequently used alloys were: (a) Cara SLM, (b) Cara Milled and (c) Wirobond® 280. Except for the difference in composition of these alloys, they were also manufactured with various techniques. In tooth-supported prostheses the dominating technique was the cast technique while newer techniques as laser-sintering and milling were more commonly reported for implant-supported constructions. A fourth technique; the ‘pre-state’ milling was reported in FDP. Conclusion: More than 30 different Co-Cr alloys were reported as being used in FP. Thus, there is a need for studies exploring the mechanical and physical behavior and the biological response to the most commonly used Co-Cr alloys. PMID:29242813
Krieger, Oliver; Matuliene, Giedre; Hüsler, Jürg; Salvi, Giovanni E; Pjetursson, Bjarni; Brägger, Urs
2009-08-01
To assess retrospectively, over at least 5 years, the incidences of technical and biological complications and failures in young adult patients with birth defects affecting the formation of teeth. All insurance cases with a birth defect that had crowns and fixed dental prostheses (FDPs) inserted more than 5 years ago were contacted and asked to participate in a reexamination. The median age of the patients was 19.3 years (range 16.6-24.7 years) when prosthetic treatment was initiated. Over the median observation period of 15.7 years (range 7.4-24.9 years) and considering the treatment needs at the reexamination, 19 out of 33 patients (58%) with reconstructions on teeth remained free from all failures or complications. From the patients with FDPs and single unit crowns (SCs) on implants followed over a median observation period of 8 years (range 4.6-15.3 years), eight out of 17% or 47% needed a retreatment or repair at some point due to a failure or a complication. From the three groups of patients, the cases with amelogenesis/dentinogenesis imperfecta demonstrated the highest failure and complication rates. In the cases with cleft lip, alveolus and palate (CLAP) or hypodontia/oligodontia, 71% of the SCs and 73% of the FDPs on teeth (FDP T) remained complication free over a median observation period of about 16 years. Sixty-two percent of the SCs and 64% of the FDPs on implants remained complication free over 8 years. Complications occurred earlier with implant-supported reconstructions. Because healthy, pristine teeth can be left unprepared, implant-supported SCs and FDPs are the treatment choice in young adults with birth defects resulting in tooth agenesis and in whom the edentulous spaces cannot be closed by means of orthodontic therapy. However, the trend for earlier and more frequent complications with implant-supported reconstructions in young adults, expecting many years of function with the reconstructions, has to be weighed against the benefits of keeping teeth unprepared. In cases with CLAP in which anatomical conditions render implant placement difficult and in which teeth adjacent to the cleft require esthetic corrections, the conventional FDP T still remains the treatment of choice.
Katsoulis, Joannis; Takeichi, Takuro; Sol Gaviria, Ana; Peter, Lukas; Katsoulis, Konstantinos
Compromised fit between the contact surfaces of screw-retained implant-supported fixed dentures (IFDs) is thought to create uncontrolled strains in the prosthetic components and peri-implant tissues, thus evoking biological and technical complications such as bone loss, screw loosening, component fractures and, at worst, loss of implants or prostheses. The aim of this systematic review was to evaluate the impact of marginal misfit on the clinical outcomes of IFDs, and to elucidate definition and assessment methods for passive fit. A systematic review of the literature was conducted with a PICO question: "For partially or complete edentulous subjects with screw-retained IFDs, does the marginal misfit at the implant-prosthesis interfaces have an impact on the clinical outcomes?". A literature search was performed electronically in PubMed (MEDLINE) with the help of Boolean operators to combine key words, and by hand search in relevant journals. English written in vivo studies published before August 31, 2016 that reported on both clinical outcome and related implant prosthesis misfit (gap, strains, torque) were selected using predetermined inclusion criteria. The initial search yielded 2626 records. After screening and a subsequent filtering process, five human and five animal studies were included in the descriptive analysis. The selected studies used different methods to assess misfit (linear distortion, vertical gap, strains, screw torque). While two human studies evaluated the biological response and technical complications prospectively over 6 and 12 months, the animal studies had an observation period < 12 weeks. Four human studies analysed retrospectively the 3 to 32 years' outcomes. Screw-related complications were observed, but biological sequelae could not be confirmed. Although the animal studies had different designs, bone adaptation and implant displacement was found in histological analyses. Due to the small number of studies and the heterogenic designs and misfit assessment methods, no meta-analysis of the data could be performed. The current literature provides insufficient evidence as to the effect of misfit at the prosthesis-implant interface on clinical outcomes of screw-retained implant-supported fixed dentures. Marginal gaps and static strains due to screw tightening were not found to have negative effects on initial osseointegration or peri-implant bone stability over time. Based on two clinical studies, the risk for technical screw-related complications was slightly higher. While the degree of tolerable misfit remains a matter of debate, the present data do not imply that clinicians neglect good fit, but aim to achieve the least misfit possible. Conflict of interest statement: The authors declare no conflict of interest. The review was conducted as part of the 2016 Foundation of Oral Rehabilitation Consensus Conference on "Prosthetic Protocols in Implant-based Oral Rehabilitation".
Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.
Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L
2013-02-01
The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.
Jaatinen, Jarkko J P; Korhonen, Rami K; Pelttari, Alpo; Helminen, Heikki J; Korhonen, Hannu; Lappalainen, Reijo; Kröger, Heikki
2011-08-01
Amorphous diamond (AD) is a durable and compatible biomaterial for joint prostheses. Knowledge regarding bone growth on AD-coated implants and their early-stage osseointegration is poor. We investigated bone growth on AD-coated cementless intramedullary implants implanted in rats. Titanium was chosen as a reference due to its well-known performance. We placed AD-coated and non-coated titanium implants (R(a) ≈ 0.2 μm) into the femoral bone marrow of 25 rats. The animals were divided in 2 groups according to implant coating and they were killed after 4 or 12 weeks. The osseointegration of the implants was examined from hard tissue specimens by measuring the new bone formation on their surface. 4 weeks after the operation, the thickness of new bone in the AD-coated group was greater than that in the non-coated group (15.3 (SD 7.1) μm vs. 7.6 (SD 6.0) μm). 12 weeks after the operation, the thickness of new bone was similar in the non-coated group and in the AD-coated group. We conclude that AD coating of femoral implants can enhance bone ongrowth in rats in the acute, early stage after the operation and might be an improvement over earlier coatings.
Cochlear Implants:System Design, Integration and Evaluation
Rebscher, Stephen; Harrison, William V.; Sun, Xiaoan; Feng, Haihong
2009-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120,000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues from design and specifications to integration and evaluation. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants. PMID:19946565
Novel Biomaterials Used in Medical 3D Printing Techniques.
Tappa, Karthik; Jammalamadaka, Udayabhanu
2018-02-07
The success of an implant depends on the type of biomaterial used for its fabrication. An ideal implant material should be biocompatible, inert, mechanically durable, and easily moldable. The ability to build patient specific implants incorporated with bioactive drugs, cells, and proteins has made 3D printing technology revolutionary in medical and pharmaceutical fields. A vast variety of biomaterials are currently being used in medical 3D printing, including metals, ceramics, polymers, and composites. With continuous research and progress in biomaterials used in 3D printing, there has been a rapid growth in applications of 3D printing in manufacturing customized implants, prostheses, drug delivery devices, and 3D scaffolds for tissue engineering and regenerative medicine. The current review focuses on the novel biomaterials used in variety of 3D printing technologies for clinical applications. Most common types of medical 3D printing technologies, including fused deposition modeling, extrusion based bioprinting, inkjet, and polyjet printing techniques, their clinical applications, different types of biomaterials currently used by researchers, and key limitations are discussed in detail.
Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol
The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.
Arinc, Hakan
2018-06-01
To evaluate the effects of prosthetic material on the degree of stress to the cortical bone, trabecular bone, framework, and implants using finite element analysis (FEA). A mandibular implant-supported fixed prosthesis was designed. Different prosthetic materials [cobalt-chromium-supported ceramic, zirconia-supported ceramic, and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin] were used. FEA was used to evaluate stress under different loading conditions. Maximum principal (σmax), minimum principal (σmin), and von Mises (σvM) stress values were obtained. Similar σmax, σmin, and σvM values were observed in the cortical and trabecular bones and in implants under both loading conditions, with the exception of the ZRPMMA model, which showed the highest σmax, σmin, and σvM values in oblique loading. The ZRPMMA model had the lowest σvM value in the framework under both loading conditions. ZRPMMA had the lowest stress values in the framework, with increased stress values in the implants and bone tissue. Framework and veneering materials may influence stress values under different loading conditions.
Biocompatibility evaluation of 3 facial silicone elastomers.
França, Diurianne Caroline Campos; de Castro, Alvimar Lima; Soubhia, Ana Maria Pires; Tucci, Renata; de Aguiar, Sandra Maria Herondina Coelho Ávila; Goiato, Marcelo Coelho
2011-05-01
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially the biocompatibility. This study aimed to evaluate the biocompatibility of maxillofacial silicones in subcutaneous tissue of rats. Thirty Wistar rats received subcutaneous implants of 3 maxillofacial silicone elastomers (LIM 6050, MDX 4-4210, and industrial Silastic 732 RTV). A histomorphometric evaluation was conducted to analyze the biocompatibility of the implants. Eight areas of 60.11 mm(2) from the surgical pieces were analyzed. Mesenchymal cells, eosinophils, and foreign-body giant cells were counted. Data were submitted to analysis of variance and Tukey test. Initially, all implanted materials exhibited an acceptable tissue inflammatory response, with tissue reactions varying from light to moderate. Afterward, a fibrous capsule around the silicone was observed. The silicones used in the current study presented biocompatibility and can be used for implantation in both medical and dental areas. Their prosthetic indication is conditioned to their physical properties. Solid silicone is easier to adapt and does not suffer apparent modifications inside the tissues.
Implant-supported single-tooth restorations. A 12-year prospective study.
Donati, Mauro; Ekestubbe, Annika; Lindhe, Jan; Wennström, Jan L
2016-10-01
The aim of this study was to evaluate prospectively the 12-year outcome of implant-supported single-tooth restorations. Originally 45 self-tapping Astra Tech TiOblast ® ST-implants were installed by a two-stage protocol in 40 subjects requiring single-tooth prosthetic replacement for a missing tooth. Clinical and radiologic examinations were performed at completion of the prosthetic treatment 4-7 months after implant installation surgery and after 5 and 12 years in function. At 12 years 31 patients and 35 implants were available for evaluation. The overall failure rate after 12 years was 10.3% on the subject level and 9.1% on the implant level. The mean bone loss amounted to 0.67 mm (SD 2.20) on a subject level and 0.47 mm (1.72) on an implant level. Three subjects (10%) and three implants (8.6%) were diagnosed with peri-implantitis. Five subjects had experienced technical complications; three incidences of loosening of the abutment retention screw during the first 5 years and two minor porcelain fracture of the crown (two patients) between 5- and 12-years of follow-up. The findings reported in this 12-year prospective case series suggest that the use of the Astra Tech dental implants may be a valid treatment alternative for single-tooth replacement prostheses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Pathological mandibular fracture: A severe complication of periimplantitis
Rodriguez-Campo, Francisco; Naval-Parra, Beatriz; Sastre-Pérez, Jesús
2015-01-01
Nowadays, dental implant treatment is a very common option for patients even in medical compromised conditons. Some complications related to them have been described. Periimplantitis (PI) is one of the biggest concerns complications of these kind of treatments, probably has a multifactorial aethiology. Usually the consequences of PI are the loss of the implants and prostheses, expenses of money and time for dentists and patients. Very often PI implies the necesity of repeating the treatment . Pathological mandibular fracture due to PI is a severe but infrequent complication after dental implant treatment, especially after PI. In this study we present three cases of mandibular pathologic fractures among patients with different medical and dental records but similar management: two of them had been treated years ago of oral squamous cell carcinoma with surgery and radiotherapy, the other patient received oral bisphosphonates for osteoporosis some years after implantation. We analized the causes, consequences and posible prevention of these fractures as well as the special features of this kind of mandibular fractures and the different existing treatments. Key words:Periimplantitis, pathological mandibular fracture, mandibular atrophy, bicortical implants. PMID:26155355
Pathological mandibular fracture: A severe complication of periimplantitis.
Naval-Gías, Luis; Rodriguez-Campo, Francisco; Naval-Parra, Beatriz; Sastre-Pérez, Jesús
2015-04-01
Nowadays, dental implant treatment is a very common option for patients even in medical compromised conditons. Some complications related to them have been described. Periimplantitis (PI) is one of the biggest concerns complications of these kind of treatments, probably has a multifactorial aethiology. Usually the consequences of PI are the loss of the implants and prostheses, expenses of money and time for dentists and patients. Very often PI implies the necesity of repeating the treatment . Pathological mandibular fracture due to PI is a severe but infrequent complication after dental implant treatment, especially after PI. In this study we present three cases of mandibular pathologic fractures among patients with different medical and dental records but similar management: two of them had been treated years ago of oral squamous cell carcinoma with surgery and radiotherapy, the other patient received oral bisphosphonates for osteoporosis some years after implantation. We analized the causes, consequences and posible prevention of these fractures as well as the special features of this kind of mandibular fractures and the different existing treatments. Key words:Periimplantitis, pathological mandibular fracture, mandibular atrophy, bicortical implants.
Decking, J; Gerber, A; Kränzlein, J; Meurer, A; Böhm, B; Plitz, W
2004-01-01
We investigated the initial stability of cementless stems implanted with robotic milling and conventional manual broaching. Proximally porous structured stems (G2, ESKA-Implants, Luebeck, Germany) were implanted into synthetic femora. In one group, the femoral cavity was prepared by a CT-based robot (CASPAR, URS-Ortho, Germany) with a high-speed milling head. In the other group, femora were rasped manually with broaches. The broaches had 1 mm proximal press-fit, the robotic cavities 1.5 mm. The implants were exposed to 15 000 loading cycles with 1 000 +/- 500 N. The direction of forces on the implant head were chosen to simulate stair climbing. Internal rotation and translation (caudal, dorsal and lateral) of the implants were measured by linear transducers. The robotic group showed significantly less reversible motion regarding translation in caudal, dorsal and lateral directions. The standard deviations of implant motions were smaller in the robotic group. Using robotic preparation of the femur, initial stability was higher and more consistent than with manual broaching, but differences in undersizing of the cavities created in the femur in relation to the implant may have contributed to these differences for the most part. In-vitro-loading experiments focusing on femoral cavities with varying press-fits are recommended before the introduction of new implants or operating procedures.
The double capsules in macro-textured breast implants.
Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A
2015-10-01
Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.
Upper extremity prosthesis user perspectives on unmet needs and innovative technology.
Benz, Heather L; Jia Yao; Rose, Laura; Olgac, Okan; Kreutz, Karen; Saha, Anindita; Civillico, Eugene F
2016-08-01
The needs of individuals with upper limb amputation and congenital limb difference are not being fully met by current prostheses, as evidenced by prosthesis rejection, non-wear, and user reports of pain and challenging activities. Emerging technologies such as dexterous sensorized robotic limbs, osseointegrated prostheses, implantable EMG electrodes, and electrical stimulation for sensory feedback have the potential to address unmet needs, but pose additional risks. We plan to assess upper limb prosthesis user needs and perspectives on these new benefits and risks using an extensive quantitative survey. In preparation for this survey, we report here on qualitative interviews with seven individuals with upper limb amputation or congenital limb difference. Unstructured text was mined using topic modeling and the results compared with identified themes. A more complete understanding of how novel technologies could address real user concerns will inform implementation of new technologies and regulatory decision-making.
Upper Extremity Prosthesis User Perspectives on Unmet Needs and Innovative Technology
Benz, Heather L.; Yao, Jia; Rose, Laura; Olgac, Okan; Kreutz, Karen; Saha, Anindita; Civillico, Eugene F.
2017-01-01
The needs of individuals with upper limb amputation and congenital limb difference are not being fully met by current prostheses, as evidenced by prosthesis rejection, non-wear, and user reports of pain and challenging activities. Emerging technologies such as dexterous sensorized robotic limbs, osseointegrated prostheses, implantable EMG electrodes, and electrical stimulation for sensory feedback have the potential to address unmet needs, but pose additional risks. We plan to assess upper limb prosthesis user needs and perspectives on these new benefits and risks using an extensive quantitative survey. In preparation for this survey, we report here on qualitative interviews with seven individuals with upper limb amputation or congenital limb difference. Unstructured text was mined using topic modeling and the results compared with identified themes. A more complete understanding of how novel technologies could address real user concerns will inform implementation of new technologies and regulatory decision-making. PMID:28268333
Farrell, Brad J; Prilutsky, Boris I; Kistenberg, Robert S; Dalton, John F; Pitkin, Mark
2014-01-01
Background Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking. Methods Full-body mechanics of walking in two cats was recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading of implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study. Findings The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4 months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth. Interpretation The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a prosthesis. Future studies with this model will help optimize the implant and prosthesis properties. PMID:24405567
PFC knee replacement: osteolytic failures from extreme polyethylene degradation.
Casey, David; Cottrell, Jocelyn; DiCarlo, Edward; Windsor, Russell; Wright, Timothy
2007-11-01
Despite the long-term success of press-fit condylar (PFC) knee prostheses, premature failures caused by aggressive rapid osteolysis have been reported. To investigate why patients experience such failures, we reviewed 48 retrieved implants and surrounding tissues together with demographic and radiographic data. Polyethylene degradation was determined from density profiles taken through the retrieved inserts. We compared the histology of tissues around PFC implants with that from around failed implants of similar designs from patients matched to length of implantation, body mass index, and age. The pathologic response in PFC patients showed more widespread, dense, sheet-like cellular infiltrate, whereas in the matched patients, the infiltrate was generally scattered discontinuously. The dominant wear mode of the PFC inserts was severe delamination on the articular surfaces. Wear damage was worse with increased length of implantation and was correlated with oxidative degradation and osteolysis. Degradation and osteolysis were more severe with inserts stored longer and sterilized by gamma radiation in air. These results underscore that degradation and increased shelf life lead to osteolysis and loosening. However, they raise questions concerning the cellular reaction to the debris from PFC implants that could lead to a better general understanding of osteolysis.
The functional performance of the Argus II retinal prosthesis
Stronks, H Christiaan; Dagnelie, Gislin
2014-01-01
Summary Visual prostheses are devices to treat profound vision loss by stimulating secondary nerve cells anywhere along the visual pathway, typically with electrical pulses. The Argus® II implant, developed by Second Sight Medical Products (SSMP, Sylmar, CA, USA), targets the retina and features 60 electrodes that electrically stimulate the surviving retinal neurons. Of the approximately 20 research groups that are actively developing visual prostheses, SSMP has the longest track record. The Argus II was the first visual prosthesis to become commercially available: It received the CE mark in Europe in 2011 and FDA approval was granted in early 2013 for humanitarian use in the USA. Meanwhile, the Argus II safety/benefit study has been extended for research purposes, and is ongoing. In this review we will discuss the performance of the Argus II in restoring sight to the blind, and we will shed light on its expected developments in the coming years. PMID:24308734
Bahraminasab, Marjan; Farahmand, Farzam
2017-09-01
The trend in biomaterials development has now headed for tailoring the properties and making hybrid materials to achieve the optimal performance metrics in a product. Modern manufacturing processes along with advanced computational techniques enable systematical fabrication of new biomaterials by design strategy. Functionally graded materials as a recent group of hybrid materials have found numerous applications in biomedical area, particularly for making orthopedic prostheses. This article, therefore, seeks to address the following research questions: (RQ1) What is the desired structure of orthopedic hybrid materials? (RQ2) What is the contribution of the literature in the development of hybrid materials in the field of orthopedic research? (RQ3) Which type of manufacturing approaches is prevalently used to build these materials for knee and hip implants? (RQ4) Is there any inadequacy in the methods applied?
Influence of trabecular bone quality and implantation direction on press-fit mechanics.
Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E
2017-02-01
Achieving primary stability of uncemented press-fit prostheses in patients with poor quality bone can involve axial implantation forces large enough to cause bone fracture. Radial implantation eliminates intraoperative impaction forces and could prevent this damage. Platens of two commercial implant surfaces ("Beaded" and "Flaked") were implanted onto trabecular bone specimens of varying quality in a press-fit simulator. Samples were implanted with varying interference, either axially (shear) or radially (normal). Push-in and pull-out forces were measured to assess stability. Microstructural changes in the bone were determined from μCT analysis. For force-defined implantation analysis, push-in and pull-out forces both increased proportionally with increasing radial force, independent of implantation direction, bone quality or implant surface. For position-defined implantation analysis, pull-out forces were generally found to increase with interference and to be greater for radial than axial implantation direction, and to be lower for poor quality bone. Bone density increased locally at the tested interface due to implantation, in particular for the Beaded surface under axial implantation. If a safe radial stress can be determined for cortical bone in a particular patient, the associated implantation force, and pull-out force which represents primary stability, can be directly derived, regardless of implantation direction, bone quality or implant surface. Radial implantation delivers primary stability that is no worse than that for axial implantation and may eliminate potentially damaging impaction forces. Development of implant designs based on this principal might improve implant fixation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:224-233, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Moráguez, Osvaldo; Vailati, Francesca; Grütter, Linda; Sailer, Irena; Belser, Urs C
2017-07-01
(1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion. Ten patients (six women, four men), mean age 49.4 ± 12.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance level P < 0.05). The 5-year implant and FDP survival rate was 100%. Mean modified plaque index (mPI) values were 0.03 and 0.02 at 3 and 5 years, significantly lower when compared to mPI (0.11 ± 0.31) at 1 year. Mean modified sulcus bleeding index (mSBI) was 0.08, 0.08, and 0.15 over time. Probing depth (PD) values were 1.57, 1.64, and 2.03 mm. Statistically significant differences were found between 1 vs. 5 year (P = 0.0003) and 3 vs. 5 year (P = 0.001). Keratinized mucosa (3.65 mm) remained stable during observation period. DIB mean values were 2.01 ± 0.34, 2.13 ± 0.13, and 2.17 ± 0.38 mm. Patient satisfaction based on visual analog scale revealed favorable fulfillment of overall treatment and esthetic expectations. Two NDIs supporting a four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Model-based Roentgen stereophotogrammetry of orthopaedic implants.
Valstar, E R; de Jong, F W; Vrooman, H A; Rozing, P M; Reiber, J H
2001-06-01
Attaching tantalum markers to prostheses for Roentgen stereophotogrammetry (RSA) may be difficult and is sometimes even impossible. In this study, a model-based RSA method that avoids the attachment of markers to prostheses is presented and validated. This model-based RSA method uses a triangulated surface model of the implant. A projected contour of this model is calculated and this calculated model contour is matched onto the detected contour of the actual implant in the RSA radiograph. The difference between the two contours is minimized by variation of the position and orientation of the model. When a minimal difference between the contours is found, an optimal position and orientation of the model has been obtained. The method was validated by means of a phantom experiment. Three prosthesis components were used in this experiment: the femoral and tibial component of an Interax total knee prosthesis (Stryker Howmedica Osteonics Corp., Rutherfort, USA) and the femoral component of a Profix total knee prosthesis (Smith & Nephew, Memphis, USA). For the prosthesis components used in this study, the accuracy of the model-based method is lower than the accuracy of traditional RSA. For the Interax femoral and tibial components, significant dimensional tolerances were found that were probably caused by the casting process and manual polishing of the components surfaces. The largest standard deviation for any translation was 0.19mm and for any rotation it was 0.52 degrees. For the Profix femoral component that had no large dimensional tolerances, the largest standard deviation for any translation was 0.22mm and for any rotation it was 0.22 degrees. From this study we may conclude that the accuracy of the current model-based RSA method is sensitive to dimensional tolerances of the implant. Research is now being conducted to make model-based RSA less sensitive to dimensional tolerances and thereby improving its accuracy.
Wireless power delivery for retinal prostheses.
Ng, David C; Williams, Chris E; Allen, Penny J; Bai, Shun; Boyd, Clive S; Meffin, Hamish; Halpern, Mark E; Skafidas, Efstratios
2011-01-01
Delivering power to an implanted device located deep inside the body is not trivial. This problem is made more challenging if the implanted device is in constant motion. This paper describes two methods of transferring power wirelessly by means of magnetic induction coupling. In the first method, a pair of transmit and receive coils is used for power transfer over a large distance (compared to their diameter). In the second method, an intermediate pair of coils is inserted in between transmit and receive coils. Comparison between the power transfer efficiency with and without the intermediate coils shows power transfer efficiency to be 11.5 % and 8.8 %, respectively. The latter method is especially suitable for powering implanted devices in the eye due to immunity to movements of the eye and ease of surgery. Using this method, we have demonstrated wireless power delivery into an animal eye.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, G.B.; Kiraly, R.J.; Nose, Y.
The objective of the study is to define the human thorax in a quantitative statistical manner such that the information will be useful to the designers of cardiac prostheses, both total replacement and assist devices. This report pertains specifically to anatomical parameters relevant to the total cardiac prosthesis. This information will also be clinically useful in that the proposed recipient of a cardiac prosthesis can by simple radiography be assured of an adequate fit with the prosthesis prior to the implantation.
Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; de Mattos, Maria da Gloria Chiarello
2012-11-01
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.
JOMJUNYONG, K.; RUNGSIYAKULL, P.; RUNGSIYAKULL, C.; AUNMEUNGTONG, W.; CHANTARAMUNGKORN, M.; KHONGKHUNTHIAN, P.
2017-01-01
SUMMARY Introduction. Although many previous studies have reported on the high success rate of short dental implants, prosthetic design still plays an important role in the long-term implant treatment results. This study aims to evaluate stress distribution characteristics involved with various prosthetic designs on standard implants or short implants in the posterior maxilla. Materials and methods. Six finite element models were simulated representing the missing first and second maxillary molars. A standard implant (PW+ implant: 5.0×10 mm) and a short implant (PW+ implant: 5.0×6.0 mm) were applied under the various prosthetic conditions. The peri-implant maximum bone stress (V on mises stress) was evaluated when 200 N 30° oblique load was applied. A type III bone was approximated and complete osseous integration was assumed. Results. Maximum Von mises stress was numerically located at the cortical bone around the implant neck in all models. In every standard implant model shows better stress distribution. Stress values and concentration area decreased in the cortical and cancellous bone when implants were splinted in both the standard and short implant models. With regard to the non-replacing second molar models found that the area of stress at the cortical bone around the first molar implant to be more intensive. Moreover, in the non-replacing second molar models, the stress also spread to the second pre-molar in both the standard and short implant models. Conclusions. The length of the implant and prosthetics designs both affect the stress value and distribution of stress to the cortical and cancellous bones around the implant. PMID:29682254
Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M
2018-01-01
Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.
Santavirta, Seppo
2003-12-01
Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.